2CSA255901R9064
Circuit Breaker, S-ARC1, 240 V, 6 A, 2 Pole, 6 kA
- Manufacturer: ABB
- Product type:
- Product Range:S-ARC1 Series; Voltage Rating VAC:240V; Voltage Rating V DC:-; Current Rating:6A; No. of Poles:2 Pole; Overload Current:6kA; Insulation Voltage:500VAC; SVHC:No SVHC (15-Jan-2
- SVHC: To Be Advised
- No. of Poles: 2 Pole
- Product Range: S-ARC1
- Current Rating: 6A
- Overload Current: 6kA
- Insulation Voltage: 500VAC
- Voltage Rating VAC: 240V
- Voltage Rating VDC: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 690.69 € |
| Current stock | 10+ |
| Lead time | 21 days |
**—** ARC FAULT DETECTION DEVICE (AFDD) ## **The new Arc Fault Detection Device S-ARC1** Maximum safety – easy installation The S-ARC1 is the new 1P+N Arc Fault Detection Device (AFDD) with an integrated Miniature Circuit Breaker (MCB) in only two module width. Besides the overcurrent protection of the MCB, the S-ARC1 provides additional protection against parallel and series arc faults. — 01 > — The S-ARC1 is an AFDD compliant to the product 01 The Arc Fault Detection Device S-ARC1 with standard “IEC 62606 - General requirements for Arc > an integrated MiniaFault Detection Devices” intended to mitigate the efture Circuit Breaker fects of arcing faults by disconnecting the circuit when an arc fault is detected. Integrated with an MCB in 6kA and 10kA breaking capacity, S-ARC1 and S-ARC1 M offer protection against overcurrents and arc faults in only two modules width. Combined with a Residual Current Circuit Breaker (RCCB) as upstream device, the S-ARC1 series provides the best solution for complete protection in the switchboard, for people, buildings, and irreplaceable goods. ## **Recommendation for any room** The use of the AFDD is additionally recommended in any rooms with sleeping facilities in private apartments, houses, hospitals (does not apply in medically use areas) and hotels. ## **Offers protection against** - Overload - Short-circuit - Earth arc fault - Parallel arc fault - Series arc fault - Overvoltage (higher than 275 V) ## **Strongly recommended applications according to the standard IEC 60364-4-42:** - **Sleeping and common rooms** in nurseries, senior and care homes, equipment for disabled persons - **Places and rooms with existing fire risks and flammable materials,** such as production facilities, barns, carpenter workshops, paper manufacturing plants or printing shops where the fire risk is high - **Places and rooms with prevailingly flammable building materials** like wood houses, flammable buildings or forced ventilation systems - **Places and rooms with irreplaceable goods (cultural assets),** such as those in museums, libraries, galleries, archives or architectural monuments ## **Application benefits** - Easy cross-wiring and easy installation with System pro M compact® busbars without any extra cables - Supply possible both from top and bottom side: double slots available for connection with cables and busbars - Family feeling in the System pro M compact® range - Compatible with System pro M compact® accessories - LED for an easy troubleshooting of the network - Test button to verify the correct working conditions of the device - Continuous internal self-test **MAXIMUM SAFETY WITH EASY INSTALLATION:** S-ARC1 ## **—** ## **S-ARC1 arc fault detection device with integrated MCB** ## Technical data ## **—** ## **Technical specifications** |||**S-ARC1**<br>**S-ARC1 M**| |---|---|---| ||Standards|IEC/EN 62606; IEC/EN 60898-1| |**Electrical**<br>**functions**|Number of poles|1P + N| ||Rated current In|A<br>6 ≤ In ≤ 20| ||Rated voltage Ue|V<br>230 – 240| ||Insulation voltage Ui|V<br>500 V AC| ||Overvoltage category|III| ||Pollution degree|2| ||Min. operating voltage|V<br>170| ||Threshold for protection against overvoltage|V<br>275| ||Rated frequency|Hz<br>50/60| ||Rated breaking capacity acc. to IEC/EN 60898-1|ultimate Icn<br>A<br>6000<br>10000| ||Rated breaking capacity acc. to IEC/EN 60947-2<br>(only referring to short circuit test)|ultimate Icu<br>kA<br>7.5<br>10| |||service Ics<br>kA<br>6<br>7.5| ||Rated residual breaking capacity I∆m|A<br>6000| ||Rated impulse withstand voltage (1.2/50) Uimp|kV<br>4| ||Dielectric test voltage at ind. freq. for 1 min.|kV<br>2.5 (50/60 Hz, 1 min.)| ||Thermomagnetic release – characteristic|B: 3 In≤ Im≤ 5 In| |||C: 5 In≤ Im≤ 10 In| ||Energy limiting class|3| |**Mechanical**<br>**main**<br>**features**|Housing|Insulation group I, RAL 7035| ||Toggle|Insulation group II, Orange RAL 2004,<br>sealable in ON-OFF-positions| ||Contact position indication|Green/red window| ||Electrical life|10000 operations| ||Mechanical life|20000 operations| ||Protection degree acc. to EN 60529|housing<br>IP4X| |||terminals<br>IP2X| ||Shock resistance acc. to IEC/EN 60068-2-27|25 g – 2 shocks – 13 ms| ||Vibration resistance acc. to IEC/EN 60068-2-6|0.2 mm or 5 g – 20 cycles at 5 … 150 … 5 Hz| ||Environmental conditions (damp heat)<br>acc. to IEC/EN 60068-2-30|°C/<br>RH<br>28 cycles with 55°C/90 – 96 % and 25°C/95 – 100 %| ||Reference temperature for setting of thermal|°C<br>30| ||Ambient temperature (with daily average ≤ +35 °C)|°C<br>-25 … +55| ||Storage temperature|°C<br>-40 … +70| |**Assembly**|Terminal type|top/bottom<br>failsafe bi-directional cylinder-lift terminal (shock-<br>protected)| ||Terminal size for cables|top/bottom<br>mm²<br>25/25| ||Terminal size for busbars|top/bottom<br>mm²<br>10/10| ||Tightening torque|top/bottom<br>Nm<br>2.8| ||Stripping length of the cable|mm<br>12| ||Mounting|on DIN rail EN 60715 (35 mm) by means of mounting clip| ||Mounting position|any| ||Supply from|Top/bottom terminals| |**Dimensions**<br>**and weight**|Dimensions (H x D x W)|mm<br>85 × 69 × 35| ||Weight|g<br>180| ARC FAULT DETECTION DEVICE WITH INTEGRATED MCB ## **—** ## **S-ARC1 AFDD with integrated MCB** Ordering details, accessories, electrical diagrams and dimensions ## **—** ## **Ordering details** |||**S-ARC1, 6kA**|**S-ARC1, 6kA**||||||| |---|---|---|---|---|---|---|---|---|---| |||**Number**|**Number**<br>**Charac-**|**Rated current**|**Bbn**|**Ordering details**|**Ordering details**|**Weight**|**Pkg**| |||**of poles**|**teristics**|**In A**|**8012542**|||**1 pcs**|**qty**| |® @|4 <br>3|**EAN**<br>**Type code**<br>**Order code**<br>**kg**<br>**pce**<br>6<br>750130<br>S-ARC1 B6<br>2CSA255901R9065<br>0.180<br>1<br> ~~a~~|||||||| |os||||10|178132|S-ARC1 B10|2CSA255901R9105|0.180|1| |-&||1P+N|B|13<br>16<br>20|750031<br>178033<br>749936|S-ARC1 B13<br>S-ARC1 B16<br>S-ARC1B20|2CSA255901R9135<br>2CSA255901R9165<br>2CSA255901R9205|0.180<br>0.180<br>0.180|1<br>1<br>1| |® ee||1P+N|C|~~6~~<br>10<br>13|~~177937~~<br>749837<br>500735|~~S-ARC1 C6~~<br>S-ARC1 C10<br>S-ARC1 C13|~~2CSA255901R9064~~<br>2CSA255901R9104<br>2CSA255901R9134|~~0.180~~<br>0.180<br>0.180|~~1~~<br>1<br>1| |||||16|886136|S-ARC1 C16|2CSA255901R9164|0.180|1| |||||20|175438|S-ARC1 C20|2CSA255901R9204|0.180|1| |**S-A**~~**RC1**~~ ~~**M, 1**~~|~~**M, 10kA**~~||||||| |---|---|---|---|---|---|---|---| |**Number**<br>**Charac-**<br>**Rated current**<br>**Bbn**<br>**Ordering details**<br>**Ordering details**<br>**Weight**<br>**Pkg**<br>~~a~~|||||||| |~~**of pole**~~**s**|~~**teris**~~**tics**|**In A**|**8012542**|||**1 pcs**|**qty**| ||||**EAN**|**Type code**|**Order code**|**kg**|**pce**| |||6|374312|S-ARC1 M B6|2CSA275901R9065|0.180|1| |||10|342113|S-ARC1 M B10|2CSA275901R9105|0.180|~~1~~| |1P~~+~~N|B|13|342014|S-ARC1 M B13|2CSA275901R9135|0.180|1| |||16|342212|S-ARC1 M B16|2CSA275901R9165|0.180|~~1~~| |||20|341215|S-ARC1 M B20|2CSA275901R9205|0.180|1| |||6|339816|S-ARC1 M C6|2CSA275901R9064|0.180|1| |1P+N|C|10<br>13|339717<br>339618|S-ARC1 M C10<br>S-ARC1 M C13|2CSA275901R9104<br>2CSA275901R9134|0.180<br>0.180|~~1~~<br>1| |||16|340416|S-ARC1 M C16|2CSA275901R9164|0.180|1| |||20|340317|S-ARC1 M C20|2CSA275901R9204|0.180|1| ## **Overall dimens** ~~**i**~~ **ons in mm** ## **Syste** ~~**m**~~ **pro M compact** ~~**®**~~ **accessories – Combinations with acc** ~~**e**~~ **ss** ~~**o**~~ **rie** ~~**s**~~ **==> picture [237 x 191] intentionally omitted <==** **----- Start of picture text -----**<br> S-ARC1<br>H-R H-R<br>H<br>S -A R C 1 S/H<br>or H<br>H Auxiliary contact S2C-H6R 1<br>S/H<br>S2C-H6- (H)<br>H-R Auxiliary contact xxR<br>Signal/auxiliary ST-F<br>S/H contact S2C-S/H6R or UR<br>Signal/auxiliary or OR<br>S/H contact used as |<br>(H) auxiliary contact S2C-S/H6R H<br>F2C-A<br>ST-F Shunt Trip S/H<br>Undervoltage or H<br>UR release S2C-A<br>S/H<br>Overvoltage (H)<br>OR release S2C-OVP<br>**----- End of picture text -----**<br> **MAXIMUM SAFETY WITH EASY INSTALLATION:** S-ARC1 ## **—** ## **S-ARC1 arc fault detection device with integrated MCB** ## Technical data ## **—** **Specific let-through energy I[2] t S-ARC1 and S-ARC1 M** **==> picture [596 x 437] intentionally omitted <==** **----- Start of picture text -----**<br> 10000 10000<br>—<br>01 I [2] t<br>S-ARC1 Tripping 1000 1000<br>Characteristics B<br>—<br>02 I [2] t<br>S-ARC1 Tripping<br>Characteristics C<br>100 100<br>500 Irms [A] 5000 500 Irms [A] 5000<br>B20 B16 B13 B10 B6 C20 C16 C13 C10 C6<br>— —<br>01 02<br>10000 10000<br>—<br>03 I [2] t<br>S-ARC1 M Tripping 1000 1000<br>Characteristics B<br>—<br>04 I [2] t<br>S-ARC1 M Tripping<br>Characteristics C<br>100 100<br>500 Irms [A] 5000 500 Irms [A] 5000<br>B20 B16 B13 B10 B6 C20 C16 C13 C10 C6<br>— —<br>03 04<br>**----- End of picture text -----**<br> ARC FAULT DETECTION DEVICE WITH INTEGRATED MCB ## **—** ## **S-ARC1 arc fault detection device with integrated MCB** Technical data ## **—** ## **Ipeak S-ARC1 and S-ARC1 M** **==> picture [596 x 437] intentionally omitted <==** **----- Start of picture text -----**<br> 10000 10000<br>—<br>01 IpeakS-ARC1 Tripping 1000 1000<br>Characteristics B<br>—<br>02 Ipeak<br>S-ARC1 Tripping<br>Characteristics C<br>100 100<br>500 Irms [A] 5000 500 Irms [A] 5000<br>B20 B16 B13 B10 B6 C20 C16 C13 C10 C6<br>— —<br>01 02<br>10000 10000<br>—<br>03 IpeakS-ARC1 M Tripping 1000 1000<br>Characteristics B<br>—<br>04 Ipeak<br>S-ARC1 M Tripping<br>Characteristics C<br>100 100<br>500 Irms [A] 5000 500 Irms [A] 5000<br>B20 B16 B13 B10 B6 C20 C16 C13 C10 C6<br>— —<br>03 04<br>Ipeak[A] Ipeak[A]<br>Ipeak[A] Ipeak[A]<br>**----- End of picture text -----**<br> **MAXIMUM SAFETY WITH EASY INSTALLATION:** S-ARC1 ## **—** ## **S-ARC1 arc fault detection device with integrated MCB** ## Technical data ## **— Technical data** |**Influence of**<br>**adjacent devices**<br>Number of<br>devices<br>Correction<br>factor|<br>1<br>3<br>5<br>7<br>9| |---|---| ||<br>1<br>0.92<br>0.88<br>0.85<br>0.84| ||| |**Derating in**<br>**temperature**<br>Max operating current<br>depending on the<br>ambient temperature<br>(daily average ≤ +35 °C)<br>of characteristics<br>type B and C.<br>**In**<br>**(A)**<br>**6**<br>**10**<br>**13**<br>**16**<br>**20**|<br>**Temperature**<br>**(°C)**| ||**-25**<br>**-20**<br>**0**<br>**10**<br>**20**<br>**25**<br>**30**<br>**40**<br>**50**<br>**55**| ||7.2<br>6.8<br>6.4<br>6.3<br>6.1<br>6.0<br>6.0<br>6.0<br>5.8<br>5.8| ||12.2<br>11.9<br>10.8<br>10.7<br>10.5<br>10.2<br>10.0<br>10.0<br>9.8<br>9.6| ||15.6<br>15.2<br>14.2<br>13.8<br>13.4<br>13.2<br>13.0<br>12.9<br>12.7<br>12.6| ||19.5<br>18.9<br>17.9<br>17.3<br>16.7<br>16.3<br>16.0<br>15.8<br>15.5<br>15.4| ||24.4<br>24.0<br>22.4<br>21.6<br>21.0<br>20.4<br>20.0<br>19.8<br>19.5<br>19.4| |**Voltage Drop,**<br>**power loss,**<br>**internal resistance,**<br>**own consumption**|**In**<br>**(A)**|<br>**Voltage drop**<br>**(mV)**<br>**Internal resistance**<br>**(m Ω)**<br>**Power loss**<br>**(W)**<br>**Own consumption**<br>**(W)**| |---|---|---| ||**6**|380<br>63.3<br>2.3<br>0.5| ||**10**|203<br>20.3<br>2.0<br>0.5| ||**13**|166<br>12.8<br>2.2<br>0.5| ||**16**|175<br>10.9<br>2.8<br>0.5| ||**20**|182<br>9.1<br>3.6<br>0.5| |||| |**Performance**<br>**in altitude**|**Elevation**<br>**(m)**|<br>**3000**<br>**4000**<br>**5000**<br>**6000**| ||Rated Current<br>(A)|<br>0.96 xIn<br>0.94 x In<br>0.92 x In<br>0.90 x In| ||Rated Voltage<br>(V)|<br>0.877 x Un<br>0.775 x Un<br>0.676 x Un<br>0.588 x Un| **—** ## **ABB S.p.A** Viale dell’Industria, 18 20010 Vittuone (MI) Phone +39 02 9034 1 Fax +39 02 9034 7609 ## **—** ## **www.new.abb.com/low-voltage/ products/system-pro-m** ## **—** We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB AG. Copyright© 2017 ABB All rights reserved
Updated at April 28, 2026
ABB is a global leader in power and automation technologies, recognized for delivering innovative solutions that improve performance while minimizing environmental impact. Serving a diverse range of sectors including industrial processing, OEM, and building services, ABB provides highly reliable components designed to meet the rigorous demands of modern electrical systems. The company is particularly renowned for its advanced circuit protection solutions. This includes a comprehensive selection of thermal magnetic circuit breakers, alongside specialized RCBO, RCD, GFCI, and AFDD circuit breakers. These foundational safety components are supported by a wide array of high-quality fuse holders and circuit breaker accessories, ensuring complete protection for complex industrial and commercial installations. Beyond circuit protection, ABB excels in automation and process control. Their offering features sophisticated visual signal indicator units, industrial switch accessories, and panel instrumentation designed for intuitive system monitoring. Additionally, ABB manufactures a robust range of power relays, safety relays, and AC/DC converters, providing engineers with the critical building blocks needed for efficient, secure, and reliable control panels.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →