2CSA255103R1104
Circuit Breaker, DS-ARC1, 240 V, 10 A, 2 Pole, 6 kA
- Manufacturer: ABB
- Product type:
- Product Range:DS-ARC1 Series; Voltage Rating VAC:240V; Voltage Rating V DC:-; Current Rating:10A; No. of Poles:2 Pole; Overload Current:6kA; Insulation Voltage:500VAC; SVHC:No SVHC (15-Ja
- SVHC: To Be Advised
- No. of Poles: 2 Pole
- Product Range: DS-ARC1
- Current Rating: 10A
- Overload Current: 6kA
- Insulation Voltage: 500VAC
- Voltage Rating VAC: 240V
- Voltage Rating VDC: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1066.62 € |
| Current stock | 10+ |
| Lead time | 21 days |
## **—** PROTECTION AGAINST ARC FAULTS ## **Arc Fault Detection Device DS-ARC1 with integrated RCBO** Data sheet DS-ARC1 is the new 1P+N AFDD with an integrated residual current circuit breaker with over-current protection (RCBO) in 6 kA and 10 kA breaking capacity. In only three-module width, DS-ARC1 series offers a complete protection against arc faults overvoltages, overcurrent, earth fault currents. — 01 > — DS-ARC1 is an AFDD compliant to the product 01 The arc fault detection device DS-ARC1 with standard “IEC 62606 – General requirements for > an integrated RCBO Arc Fault Detection Devices” intended to mitigate the effects of arcing faults by disconnecting the circuit when an arc fault is detected. DS-ARC1 is integrated with an RCBO for a complete protection against overcurrents, earth fault currents and arc faults in only three modules width. ## **Recommendation for any room** The use of the AFDD is additionally recommended in any rooms with sleeping facilities in private apartments, houses, hospitals (does not apply in medically use areas) and hotels. ## **Offers protection against** - Earth arc fault - Parallel arc fault - Series arc fault ## **Strongly recommended applications according to the standard IEC 60364-4-42:** - **Sleeping and common rooms** in nurseries, senior and care homes, equipment for disabled persons - **Places and rooms with existing fire risks and flammable materials,** such as production facilities, barns, carpenter workshops, paper manufacturing plants or printing shops where the fire risk is high - **Places and rooms with prevailingly flammable building materials** like wood houses, flammable buildings or forced ventilation systems - **Places and rooms with irreplaceable goods (cultural assets),** such as those in museums, libraries, galleries, archives or architectural monuments - Overvoltage (higher than 275 V) - Overload - Short-circuit - Earth fault currents ## **Application benefits** - Easy cross-wiring and easy installation with System pro M compact® busbars without any extra cables - Supply possible both from top and bottom side: double slots available for connection with cables and busbars - Family feeling in the System pro M compact® range - Compatible with System pro M compact® accessories - LED for an easy troubleshooting of the network - Two test button to verify the correct working conditions of AFDD and RCD - Continuous internal self-test **DS_ARC1 DATA SHEET** TECHNICAL DATA ## **—** ## **DS-ARC1 arc fault detection device with integrated RCBO** ## Technical data ## **—** ## **Technical specifications** |||**DS-ARC1**<br>**DS-ARC1 M**| |---|---|---| ||Standards|IEC/EN 62606; IEC/EN 61009-1; IEC/EN 61009-2-1| |**Electrical**<br>**Functions**|Type (wave form of the earth leakage sensed)|A| ||Number of poles|1P + N| ||Rated current In|A<br>6≤In≤20| ||Rated sensitivity I∆n|A<br>0.03| ||Rated voltage Ue|V<br>230 – 240| ||Insulation voltage Ui|V<br>500 V AC| ||Overvoltage category|III| ||Pollution degree|2| ||Operating voltage of RCD circuit test Ut|V<br>170 – 264| ||Threshold for protection against overvoltage|V<br>275| ||Rated frequency|Hz<br>50/60| ||Rated breaking capacity acc. to IEC/EN 61009-1|ultimate Icn<br>A<br>6000<br>10000| ||Rated breaking capacity acc. to IEC/EN 60947-2<br>(only referring to short circuit test)|ultimate Icu<br>kA<br>7.5<br>10| |||service Ics<br>kA<br>6<br>7.5| ||Rated residual breaking capacity I∆m|A<br>6000| ||Rated impulse withstand voltage (1.2/50) Uimp|kV<br>4| ||Dielectric test voltage at ind. freq. for 1 min.|kV<br>2.5 (50/60 Hz, 1 min.)| ||Thermomagnetic release – characteristic|B: 3 In ≤Im ≤5 In| |||C: 5 In ≤Im ≤10 In| ||Energy limiting class|3| ||Surge current resistance (wave 8/20)|NA| |**Mechanical**<br>**Main features**|Housing|Insulation group I, RAL 7035| ||Toggle|Insulation group II,<br>Orange RAL 2004, sealable in ON-OFF-positions| ||Contact position indication|Green/red window| ||Earth fault trip indication|Blue flag on toggle| ||Electrical life|10000 operations| ||Mechanical life|20000 operations| ||Protection degree acc. to EN 60529|housing<br>IP4X| |||terminals<br>IP2X| ||Shock resistance acc. to IEC/EN 60068-2-27|25 g – 2 shocks – 13 ms| ||Vibration resistance acc. to IEC/EN 60068-2-6|0.2 mm or 5 g – 20 cycles at 5 … 150 … 5 Hz| ||Environmental conditions (damp heat)<br>acc. to IEC/EN 60068-2-30|°C/<br>RH<br>28 cycles with 55°C/90 – 96 % and 25°C/95 – 100 %| ||Reference temperature for setting of thermal element|°C<br>30| ||Ambient temperature (with daily average≤+35 °C)|°C<br>-25 … +55| ||Storage temperature|°C<br>-40 … +70| |**Assembly**|Terminal type|top/bottom<br>failsafe bi-directional cylinder-lift terminal (shock-<br>protected)| ||Terminal size for cables|top/bottom<br>mm²<br>25/25| ||Terminal size for busbars|top/bottom<br>mm²<br>10/10| ||Tightening torque|top/bottom<br>Nm<br>2.8| ||Stripping length of the cable|mm<br>12| ||Mounting|on DIN rail EN 60715 (35 mm) by means of mounting clip| ||Mounting position|any| ||Supply from|Top/bottom terminals| |**Dimensions**<br>**and weight**|Dimensions (H × D × W)|mm<br>85 × 69 × 52.5| ||Weight|g<br>240| **DS-ARC1 DATA SHEET** I TECHNICAL DETAILS ## **—** ## **DS-ARC1 AFDD with integrated RCBO** Ordering details, accessories, electrical diagrams and dimensions ## **—** ## **DS-ARC1, 6 kA** |**Number**|**Rated**|**Charac-**|**Rated**|**Bbn**|**Ordering details**|**Order data**|**Weight**|**Pkg**| |---|---|---|---|---|---|---|---|---| |**of poles**|**residual**|**teristics**|**current**|**8012542**|||**1 pcs**|**qty**| ||**currrent**||**In A**|**EAN**|**Type code**|**Order code**|**kg**|**pce**| ||**I**∆**m mA**|||||||| ||||6|736516|DS-ARC1 B6 A30|2CSA255103R1065|0.240|1| ||||10|735618|DS-ARC1 B10 A30|2CSA255103R1105|0.240|1| |1P+N|30|**B**|13|736417|DS-ARC1 B13 A30|2CSA255103R1135|0.240|1| ||||16<br>20<br>6|735519<br>736318<br>736110|DS-ARC1 B16 A30<br>DS-ARC1 B20 A30<br>DS-ARC1 C6 A30|2CSA255103R1165<br>2CSA255103R1205<br>2CSA255103R1064|0.240<br>0.240<br>0.240|1<br>1<br>1| ||||10|735212|DS-ARC1 C10 A30|2CSA255103R1104|0.240|1| |1P+N|30|**C**|13|748311|DS-ARC1 C13 A30|2CSA255103R1134|0.240|1| ||||16|611110|DS-ARC1 C16 A30|2CSA255103R1164|0.240|1| ||||20|735113|DS-ARC1 C20 A30|2CSA255103R1204|0.240|1| ## **—** ## **DS-ARC1 M, 10 kA** |**Number**|**Rated**|**Charac-**|**Rated**|**Bbn**|**Ordering details**||**Weight**|**Pkg**| |---|---|---|---|---|---|---|---|---| |**of poles**|**residual**|**teristics**|**current**|**8012542**|||**1 pcs**|**qty**| ||**currrent**||**In A**|**EAN**|**Type code**|**Order code**|**kg**|**pce**| ||**I**∆**m mA**|||||||| ||||6<br>10|734710<br>733812|DS-ARC1 M B6 A30<br>DS-ARC1 M B10 A30|2CSA275103R1065<br>2CSA275103R1105|0.240<br>0.240|1<br>1| |1P+N|30|**B**|13|734611|DS-ARC1 M B13 A30|2CSA275103R1135|0.240|1| ||||16<br>20<br>6|733713<br>734512<br>734314|DS-ARC1 M B16 A30<br>DS-ARC1 M B20 A30<br>DS-ARC1 M C6 A30|2CSA275103R1165<br>2CSA275103R1205<br>2CSA275103R1064|0.240<br>0.240<br>0.240|1<br>1<br>1| |1P+N|30|**C**|10<br>13|733416<br>748113|DS-ARC1 M C10 A30<br>DS-ARC1 M C13 A30|2CSA275103R1104<br>2CSA275103R1134|0.240<br>0.240|1<br>1| ||||16|611011|DS-ARC1 M C16 A30|2CSA275103R1164|0.240|1| ||||20|748014|DS-ARC1 M C20 A30|2CSA275103R1204|0.240|1| FAULT ANALYSIS AND EARTH FAULT INDICATOR ## **—** ## **DS-ARC1 AFDD with integrated RCBO** Fault analysis and earth fault indicator ## **—** ## **Easy fault analysis** In the case of a fault, the LED displays the different fault indications as soon as the toggle has been reclosed. |**LED color**|**blink/sec**|**Signal**<br>**duration**|**Cause of**<br>**tripping**| |---|---|---|---| |Green|permanent|permanent|Manual tripping, test<br>button, overcurrent| |Red blinking|1|5 sec|Series arc fault| |Red blinking|2|5 sec|Parallel arc fault| |Red blinking|3|5 sec|Over-voltage| After the 5 second blinking the LED turns green again. ## **—** ## **Earth fault indicator** DS-ARC1 is equipped with an earth fault indicator to identify earth fault trips. A blue flag on the toggle will appear making the troubleshooting easier while reducing the downtime for maintenance operations. In case of earth fault trip, the LED becomes green after reclosing the toggle. **DS-ARC1 DATA SHEET** I DIMENSIONS AND CONNECTIONS ## **—** ## **DS-ARC1 AFDD with integrated RCBO** ## Dimensions and connections ## **—** ## **Overall dimensions** All measurements in mm **==> picture [525 x 269] intentionally omitted <==** **----- Start of picture text -----**<br> 52,2 69<br>85 45<br>6,8<br>44<br>17,5<br>**----- End of picture text -----**<br> ## **—** **System pro M compact® accessories – Combinations with accessories** **==> picture [308 x 285] intentionally omitted <==** **----- Start of picture text -----**<br> DS-ARC1<br>H-R H-R<br>H<br>S/H<br>H-BF or H<br>S/H<br>(H)<br>ST-F<br>or UR<br>or OR<br>H<br>S/H<br>or H<br>S/H<br>(H)<br>**----- End of picture text -----**<br> |||**DS-ARC1**| |---|---|---| |H|Auxiliary contact|S2C-H6R| |H-R|Auxiliary contact|S2C-H6-xxR| |S/H|Signal/auxiliary<br>contact|S2C-S/H6R| |S/H<br>(H)|Signal/auxiliary<br>contact used as<br>auxiliary contact|S2C-S/H6R| |ST-F|Shunt Trip|F2C-A| |UR|Undervoltage release|S2C-A| |OR|Overvoltage release|S2C-OVP| |H BF|Auxiliary contact for<br>bottom fitting|S2C-H01/S2C-H10| **LET-THROUGH ENERGY CURVES** ## **—** ## **DS-ARC1 arc fault detection device with integrated RCBO** ## Technical data ## **—** **Specific let-through energy I[2] t DS-ARC1 and DS-ARC1 M** **==> picture [596 x 437] intentionally omitted <==** **----- Start of picture text -----**<br> 100000 100000<br>10000 10000<br>—<br>01 I [2] t<br>DS-ARC1<br>Characteristics C<br>1000 1000<br>—<br>02 I [2] t<br>DS-ARC1 M<br>Characteristics C<br>100 100<br>0,5 1,5 2,5 3,5 4,5 5,5 6,5 0,5 1,5 2,5 3,5 4,5 5,5 6,5 7,5 8,5 9,5 10,5<br>Perspective short-circuit current [kA] Perspective short-circuit current [kA]<br>C6 C10 C13 C16 C20 C6 C10 C13 C16 C20<br>— —<br>01 02<br>100000 100000<br>10000 10000<br>—<br>03 I [2] t<br>DS-ARC1<br>Characteristics B<br>1000 1000<br>—<br>04 I [2] t<br>DS-ARC1 M<br>Characteristics B<br>100 100<br>0,5 1,5 2,5 3,5 4,5 5,5 6,5 0,5 1,5 2,5 3,5 4,5 5,5 6,5 7,5 8,5 9,5 10,5<br>Perspective short-circuit current [kA] Perspective short-circuit current [kA]<br>C6 C10 C13 C16 C20 C6 C10 C13 C16 C20<br>— —<br>03 04<br>Specific let-through [A2s] 2 It Specific let-through [A2s] 2 It<br>Specific let-through [A2s] 2 It Specific let-through [A2s] 2 It<br>**----- End of picture text -----**<br> **DS-ARC1 DATA SHEET** I IPEAK CURVES ## **—** ## **DS-ARC1 arc fault detection device with integrated RCBO** ## Technical data ## **—** ## **Ipeak DS-ARC1 and DS-ARC1 M** **==> picture [596 x 437] intentionally omitted <==** **----- Start of picture text -----**<br> 10000 10000<br>—<br>01 Ipeak<br>DS-ARC1, 1000 1000<br>Characteristic C<br>—<br>02 Ipeak<br>DS-ARC1 M<br>Characteristics C<br>100 100<br>0,5 1,5 2,5 3,5 4,5 5,5 6,5 0,5 1,5 2,5 3,5 4,5 5,5 6,5 7,5 8,5 9,5 10,5<br>Irms [kA] Irms [kA]<br>C6 C10 C13 C16 C20 C6 C10 C13 C16 C20<br>— —<br>01 02<br>10000 10000<br>—<br>03 Ipeak<br>DS-ARC1 1000 1000<br>Characteristics B<br>—<br>04 Ipeak<br>DS-ARC1 M<br>Characteristics B<br>100 100<br>0,5 1,5 2,5 3,5 4,5 5,5 6,5 0,5 1,5 2,5 3,5 4,5 5,5 6,5 7,5 8,5 9,5 10,5<br>Irms [kA] Irms [kA]<br>C6 C10 C13 C16 C20 C6 C10 C13 C16 C20<br>— —<br>03 04<br>lp [A] lp [A]<br>lp [A] lp [A]<br>**----- End of picture text -----**<br> **DS-ARC1 DATA SHEET** I DERATING ## **—** ## **DS-ARC1 arc fault detection device with integrated RCBO** ## Technical data ## **— Derating** |**Influence of**<br>**adjacent devices**<br>Number of<br>devices<br>Correction<br>factor|<br>1<br>3<br>5<br>7<br>9| |---|---| ||<br>1<br>0.95<br>0.92<br>0.9<br>0.9| ||| |**Derating in**<br>**temperature**<br>Max operating current<br>depending on the<br>ambient temperature<br>(daily average≤+35<br>°C) of characteristics<br>type B and C.<br>**In**<br>**(A)**<br>**6**<br>**10**<br>**13**<br>**16**<br>**20**|<br>**Temperature**<br>**(°C)**| ||**-25**<br>**-20**<br>**-10**<br>**0**<br>**10**<br>**20**<br>**25**<br>**30**<br>**40**<br>**50**<br>**55**| ||7.9<br>7.8<br>7.7<br>7.3<br>6.9<br>6.3<br>6.1<br>6.0<br>5.9<br>5.8<br>5.7| ||13.3<br>13.1<br>12.8<br>12.3<br>11.5<br>10.6<br>10.3<br>10.0<br>9.9<br>9.8<br>9.8| ||17.0<br>16.7<br>16.2<br>15.5<br>14.5<br>13.6<br>13.3<br>13.0<br>12.7<br>12.6<br>12.5| ||19.6<br>19.2<br>18.5<br>18.0<br>17.2<br>16.7<br>16.4<br>16.0<br>15.9<br>15.7<br>15.6| ||24.3<br>23.8<br>23.2<br>22.3<br>21.4<br>20.7<br>20.3<br>20.0<br>19.8<br>19.5<br>19.3| |**Voltage Drop.**<br>**power loss.**<br>**internal resistance.**<br>**own consumption**|**In**<br>**(A)**|<br>**Voltage drop**<br>**(mV)**<br>**Internal resistance**<br>**(m**Ω**)**<br>**Power loss**<br>**(W)**<br>**Own consumption**<br>**(W)**| |---|---|---| ||**6**|408<br>68<br>2.5<br>0.5| ||**10**|183<br>18<br>1.8<br>0.5| ||**13**|195<br>20<br>2.0<br>0.5| ||**16**|194<br>12<br>3.1<br>0.5| ||**20**|212<br>11<br>4.2<br>0.5| |||| |**Performance**<br>**in altitude**|**Elevation**<br>**(m)**|<br>**3000**<br>**4000**<br>**5000**<br>**6000**| ||Rated Current<br>(A)|<br>0.96×In<br>0.94×In<br>0.92×In<br>0.90×In| ||Rated Voltage<br>(V)|<br>0.877×Un<br>0.775×Un<br>0.676×Un<br>0.588×Un| **—** ## **ABB S.p.A** Viale dell’Industria, 18 20010 Vittuone (MI) Phone +39 02 9034 1 Fax +39 02 9034 7609 ## **—** ## **www.new.abb.com/low-voltage/ products/system-pro-m** ## **—** We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB AG. Copyright© 2018 ABB All rights reserved
Updated at April 28, 2026
ABB is a global leader in power and automation technologies, recognized for delivering innovative solutions that improve performance while minimizing environmental impact. Serving a diverse range of sectors including industrial processing, OEM, and building services, ABB provides highly reliable components designed to meet the rigorous demands of modern electrical systems. The company is particularly renowned for its advanced circuit protection solutions. This includes a comprehensive selection of thermal magnetic circuit breakers, alongside specialized RCBO, RCD, GFCI, and AFDD circuit breakers. These foundational safety components are supported by a wide array of high-quality fuse holders and circuit breaker accessories, ensuring complete protection for complex industrial and commercial installations. Beyond circuit protection, ABB excels in automation and process control. Their offering features sophisticated visual signal indicator units, industrial switch accessories, and panel instrumentation designed for intuitive system monitoring. Additionally, ABB manufactures a robust range of power relays, safety relays, and AC/DC converters, providing engineers with the critical building blocks needed for efficient, secure, and reliable control panels.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.