2966207
General Purpose Relay, PLC Series, Interface, Non Latching, SPDT, 230 VAC, 6 A
- Manufacturer: PHOENIX CONTACT
- Product type: Power Relays
- Contact Configuration:SPDT; Coil Voltage:230VAC; Contact Current:6A; Product Range:-; Relay Mounting:Socket; Coil Type:Non Latching; Contact Voltage VAC:250VAC; Relay Terminals:Quick Connect; Con
- SVHC: Hexahydromethylphthalic anhydride [1], Hexahydro-4-methylphthalic anhydride [2], Hexahydro-1-methylphthalic anhydride[3] (04-Feb-2026)
- Coil Type: Non Latching
- Coil Voltage: 230VAC
- Product Range: PLC-INTERFACE Series
- Relay Mounting: Socket
- Coil Resistance: -
- Contact Current: 6A
- Relay Terminals: Quick Connect
- Contact Material: Silver Tin Oxide
- Contact Voltage VAC: 250V
- Contact Voltage VDC: 250V
- Contact Configuration: SPDT
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 17.47 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **PLC-RS…/21** ## **PLC INTERFACE With PDT Relay, Universal Version** ## **INTERFACE** Data Sheet 101780_en_02 © PHOENIX CONTACT - 03/2008 ## **1 Description** **PLC-RS…/21** relay modules, which can be used universally, comprise 6.2 mm basic terminal blocks and plug-in miniature relays with PDT contact and screw or spring-cage connection. ## **1.1 PDT Offers a High Degree of Flexibility** The PLC-RS…/21 universal PDT module is used whenever an application requires a high degree of flexibility. It can be used either as an input or output module or in N/O, N/C or PDT contact applications. This offers the advantage of fewer ordering and warehousing items. PLC INTERFACE modules are supplied fully equipped with a relay as standard. ## **1.2 Input Voltages From 12 V to 230 V** PLC-RS…/21 is available on the coil side in all common industrial voltages from 12 V to 230 V. A further advantage is the ready-integrated input circuit. It consists of a status indicator as well as free-wheeling diode and polarity reversal protection function, and ensures that the operating state is displayed clearly, also offering reliable EMI suppression for the coils and preventing destruction should the polarity be accidentally reversed. ## **1.3 Optimum Use of Plug-In Bridges** The PLC INTERFACE module achieves maximum efficiency with the user-friendly FBST plug-in bridge system. The PLC-RS…/21 makes effective use of the bridging options for the A1/A2 connection on the coil side and for the grouped power supply at connection 11 on the contact side. Especially effective here are the 500 mm long colorinsulated continuous plug-in bridges that can easily be cut to the required length and quickly inserted in the bridge shafts. They eliminate the need for complicated and timeconsuming loop bridges. ## **1.4 Additional Advantages** - Operational safety with RT III (IP67)-protected mechanics - Environmentally friendly, cadmium-free power contact material for loads up to 250 V AC/6 A - Available with gold coating for low power levels (mA) as an option - Integrated input circuit - Relay can be replaced using an engagement lever - Safe isolation according to DIN EN 50178 - Inflammability class V0 according to UL94 Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf. ~~eee~~ This data sheet is valid for all products listed on the following page: ~~Ee~~ **PLC-RS…/21** ## **2 Ordering Data** |**PLC INTERFACE With Screw Connection**|**PLC INTERFACE With Screw Connection**||||| |---|---|---|---|---|---| |**Description**||**Type**|**Order No.**|**Pcs./Pck.**|| |**PLC INTERFACE With Multi-Layer Contact Relay, Universal Version**|||||| |PLC INTERFACE, comprising PLC-BSC.../21|12 V DC|PLCRSC- 12DC/21AU|2966919|10|| |basic terminal block and plug-in miniature relay<br>(see INTERFACE catalog), for mounting on3|24 V DC<br>24 V AC/DC|PLCRSC- 24DC/21AU<br>PLCRSC- 24UC/21AU|2966265<br>2966278|10<br>10|| ||48 V DC|PLCRSC- 48DC/21AU|2966126|10|| ||60 V DC|PLCRSC- 60DC/21AU|2966142|10|| ||120 V AC/110 V DC|PLCRSC-120UC/21AU|2966281|10|| ||230 V AC/220 V DC1|PLCRSC-230UC/21AU|2966294|10|| |**PLC INTERFACE With Power Contact Relay, Universal Version**|||||| |PLC INTERFACE, comprising PLC-BSC.../21|12 V DC|PLCRSC- 12DC/21|2966906|10|| |basic terminal block and plug-in miniature relay<br>(see INTERFACE catalog), for mounting on3|24 V DC<br>24 V AC/DC|PLCRSC- 24DC/21<br>PLCRSC- 24UC/21|2966171<br>2966184|10<br>10|| ||48 V DC|PLCRSC- 48DC/21|2966113|10|| ||60 V DC|PLCRSC- 60DC/21|2966139|10|| ||120 V AC/110 V DC|PLCRSC-120UC/21|2966197|10|| ||230 V AC/220 V DC1|PLCRSC-230UC/21|2966207|10|| - 1 The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules (see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging. |**PLC INTERFACE With Spring-Cage Connection**|**PLC INTERFACE With Spring-Cage Connection**||||| |---|---|---|---|---|---| |**Description**||**Type**|**Order No.**|**Pcs./Pck.**|| |**PLC INTERFACE With Multi-Layer Contact Relay, Universal Version**|||||| |PLC INTERFACE, comprising PLC-BSC.../21|12 V DC|PLCRSP- 12DC/21AU|2967442|10|| |basic terminal block and plug-in miniature relay<br>(see INTERFACE catalog), for mounting on3|24 V DC<br>24 V AC/DC|PLCRSP- 24DC/21AU<br>PLCRSP- 24UC/21AU|2966540<br>2966553|10<br>10|| ||48 V DC|PLCRSP- 48DC/21AU|2966566|10|| ||60 V DC|PLCRSP- 60DC/21AU|2966579|10|| ||120 V AC/110 V DC|PLCRSP-120UC/21AU|2966582|10|| ||230 V AC/220 V DC1|PLCRSP-230UC/21AU|2966647|10|| |**PLC INTERFACE With Power Contact Relay, Universal Version**|||||| |PLC INTERFACE, comprising PLC-BSC.../21|12 V DC|PLCRSP- 12DC/21|2967439|10|| |basic terminal block and plug-in miniature relay<br>(see INTERFACE catalog), for mounting on3|24 V DC<br>24 V AC/DC|PLCRSP- 24DC/21<br>PLCRSP- 24UC/21|2966472<br>2966485|10<br>10|| ||48 V DC|PLCRSP- 48DC/21|2966498|10|| ||60 V DC|PLCRSP- 60DC/21|2966511|10|| ||120 V AC/110 V DC|PLCRSP-120UC/21|2966524|10|| ||230 V AC/220 V DC1|PLCRSP-230UC/21|2966537|10|| - 1 The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules (see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging. With the 120 V and 230 V modules, an REL-MR-60DC/... 60 V relay is normally used due to the input circuit integrated in the basic terminal block. For the protection of input and output, inductive loads must be dampened with an effective protective circuit. PHOENIX CONTACT **2** **101780_en_02** **PLC-RS…/21** |**Accessories**|**Accessories**| |---|---| |**Description**<br>**Type**<br>**Order No.**<br>**Pcs./Pck.**|| |Insulating plate<br>PLC-ATP BK<br>2966841<br>25|| ||The PLC-ATP BK insulating plate should be used in the following cases: always fit at the start and end of a PLC terminal strip for voltages<br>greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules (FBST 8-PLC... or FBST 500... can be used for<br>potential bridging) and for safe isolation between adjacent modules.| |For additional accessories such as power terminal blocks and plug-in bridges, please refer to the INTERFACE catalog or www.phoenixcontact.com<br>.|| ## **3 Technical Data** |**Input Data**|**...24DC...**|**...24UC...**|**...24UC...**|**...120UC...**|**...230UC...**| |---|---|---|---|---|---| |Nominal input voltage1|24 V DC|24 V AC/DC||120 V AC/|230 V AC/| |||||110 V DC|220 V DC| |Permissible range (with reference to UN)||See "Operating|Voltage Ranges" on page 5||| |Typical input current at UN|9 mA|11 mA/8.5|mA|3.5 mA/3 mA|3 mA| |Typical response time at UN|4 ms|6 ms||6 ms|7 ms| |Typical release time at UN|8 ms|15 ms||15 ms|15 ms| |Input circuit|Yellow LED,||Yellow LED, bridge rectifier||| ||protection||||| ||against polarity||||| ||reversal, free-||||| ||wheeling diode||||| > 1 The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules (see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging. |**Output Data**||**PLC-...21**|**PLC-...21AU**| |---|---|---|---| |Contact type||Single contact, SPDT|| |Contact material||AgSnO|AgSnO + 5μA1| |Maximum switching voltage||250 V AC/DC2|30 V AC/36 V DC| |Minimum switching voltage||12 V AC/DC|100 mV| |Limiting continuous current||6 A|50 mA| |Maximum inrush current||30 A (for AC 15 operation)|50 mA| |Minimum switching current||10 mA|1 mA| |Maximum shutdown power||Ohmic loadτ= 0 ms|Ohmic loadτ= 0 ms| ||24 V DC|140 W|1.2 W| ||48 V DC|20 W|–| ||60 V DC|18 W|–| ||110 V DC|23 W|–| ||220 V DC|40 W|–| ||250 V AC|1500 VA|–| |Minimum switching power||120 mW|10μW| - 1 If the specified maximum values are exceeded, the gold coating will be damaged. In subsequent operation, the AgSnO contact values given here will apply. This can then result in reduced service life, similar to dedicated power contacts. > 2 The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules (see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging. |**General Data**|| |---|---| |Impulse voltage withstand level|4 kV, 50 Hz, 1 min.| |Ambient temperature range|| |Operation|-25°C ... 60°C (230 V type -25°C ... 55°C)| |Storage/transport|-40°C ... 85°C| |Nominal operating mode|100% operating factor| |Inflammability class according to UL 94 (housing)|V0| |Mechanical service life|2 x 107cycles| PHOENIX CONTACT **3** **101780_en_02** **PLC-RS…/21** |**General Data(Continued)**|| |---|---| |Air and creepage distances between the circuits1|IEC 60664, IEC 60664 A, DIN VDE 0110, DIN EN 50178/VDE 0106-160,| ||IEC 60255/DIN VDE 0435| |Pollution degree|3| |Surge voltage category|III| |Mounting position|Any| |Mounting|Can be aligned without spacing| |Conductor cross-section|| |Solid, with screw connection|0.14 mm2... 2.5 mm2(26 - 14 AWG)| |Stranded, with screw connection|0.14 mm2... 1.5 mm2(26 - 14 AWG)| |Solid, with spring-cage connection|0.2 mm2... 2.5 mm2(24 - 14 AWG)| |Stranded, with spring-cage connection|0.2 mm2... 1.5 mm2(24 - 14 AWG)| |Stripping length|| |Screw connection|10 mm| |Spring-cage connection|8 mm| |Dimensions (W x H x D)|6.2 mm x 94 mm x 80 mm| |Housing material|Polyamide PA, green| > 1 The PLC-ATP BK insulating plate must be installed for safe isolation between adjacent modules (see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging. **Tests/Approvals** CE c UL U u GL F ## **4 Block Diagram** **==> picture [235 x 141] intentionally omitted <==** **----- Start of picture text -----**<br> A2 11<br>A1 14<br>1)<br>12<br>1) The input circuit<br>depends on the type<br>**----- End of picture text -----**<br> PHOENIX CONTACT **4** **101780_en_02** **PLC-RS…/21** ## **5 Operating Voltage Ranges** **==> picture [234 x 190] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>U N 1,4 A<br>1,3<br>1,2<br>1,1<br>UN= 24 V DC<br>1<br>0,9<br>0,8<br>B<br>0,7<br>20 25 30 35 40 45 50 55 60 65<br>TU [ °C]<br>**----- End of picture text -----**<br> Figure 1 Operating voltage range for 24 V DC **==> picture [234 x 182] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>U N 1,4 A<br>1,3<br>1,2<br>1,1<br>UN= 24 V DC / 24 V AC<br>1<br>0,9<br>0,8<br>B<br>0,7<br>20 25 30 35 40 45 50 55 60 65<br>TU [ °C]<br>**----- End of picture text -----**<br> Figure 2 Operating voltage range for 24 V AC/DC **==> picture [233 x 190] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>U N 1,4 A<br>1,3<br>1,2<br>1,1<br>UN= 110V DC / 120V AC<br>1<br>0,9<br>0,8<br>B<br>0,7<br>20 25 30 35 40 45 50 55 60 65<br>TU [ °C]<br>**----- End of picture text -----**<br> Figure 3 Operating voltage range for 120 V AC/DC **==> picture [233 x 190] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>U N 1,4<br>1,3<br>1,2 A<br>1,1<br>UN= 220V DC / 230V AC<br>1<br>0,9<br>0,8<br>B<br>0,7<br>20 25 30 35 40 45 50 55 60 65<br>TU [ °C]<br>**----- End of picture text -----**<br> Figure 4 Operating voltage range for 230 V AC/DC ## **General Conditions** Direct alignment in the block, all devices 100% operating factor, horizontal or vertical mounting. ## **Curve A** Maximum permissible continuous voltage Umax with limiting continuous current on the contact side ## **Curve B** Minimum permissible operate voltage Uop following preexcitation **PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49 - 52 35 - 30 0 PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300 www.phoenixcontact.com** **5** **101780_en_02**
Updated at June 5, 2026
Phoenix Contact is a global leader in industrial connection technology, automation systems, and electronic interface solutions. With decades of engineering heritage originating in Germany, the company develops robust components designed to ensure reliable power, data, and signal transmission across demanding manufacturing and industrial environments. The cornerstone of the Phoenix Contact portfolio is its industry-leading selection of connection technologies. The range features an exceptional variety of terminal blocks, including pluggable headers and sockets, highly reliable wire-to-board solutions, and versatile DIN rail terminal blocks. These foundational connectivity components are supported by a comprehensive ecosystem of power distribution blocks, interface modules, marking systems, and accessories engineered for seamless control cabinet wiring. Beyond physical connectivity, Phoenix Contact provides critical components for advanced automation, control, and system protection. The wider offering encompasses a broad spectrum of process controllers, high-efficiency AC/DC converters, and a comprehensive suite of power, safety, and solid-state relays. From precision signal converters and electronic circuit breakers to fiber optic cable assemblies, Phoenix Contact equips engineers with the high-performance technologies required to build secure, highly efficient, and future-ready industrial systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →