Image not available
Illustrative purposes only
254-TXX-M-4-030
Signal Converter, Current, Voltage, Power, Frequency, Current, Voltage, 480 VAC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TE CONNECTIVITY - CROMPTON
- Product type: Signal Converters
- SVHC: To Be Advised
- Accuracy %: -
- Product Range: 254-TXX Series
- Supply Voltage: 480VAC
- Isolation Input: Isolated
- No. of Channels: -
- Output Accuracy: -
- No. of Output Channels: -
- Signal Conditioner Input: Current, Voltage, Power, Frequency
- Signal Conditioner Output: Current, Voltage
- Signal Conditioner Mounting: DIN Rail
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1011.81 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **254-TXX** ## **RELEVANT STANDARDS AND TEST REPORTS** - IEC 61326 - IEC 61010-1 - IEC62053-21 - EN60688 - RoHS Compliant - UL Certified ## **PALADIN ADVANTAGE UNIVERSAL PROGRAMMABLE TRANSDUCER** ## **KEY FEATURES** - DIN-rail enclosure - Measurement, isolation - & conversion of up to 31 electrical parameters - RS485 Modbus RTU protocol as standard - Ethernet or USB options - Versatile programmable relay output - Programmable VT/CT ratio TE Connectivity’s (TE) Crompton Instruments Paladin Advantage, 254-TXX is a programmable transducer which provides measurement, isolation and conversion of all main electrical parameters into an industry standard DC output signal. The 254-TXX can be used in single and three-phase balanced or unbalanced three or four-wire electrical systems. The 254-TXX has an accuracy of CL0.2 and includes RS485 Modbus RTU communications protocol and pulse/alarm output as standard. The 254-TXX is an accurate device for the conversion of all main electrical parameters into 2 or 4 fully isolated Voltage or mA outputs. Designed, developed and manufactured in the UK, with an integrated microprocessor for exceptional handling of distorted waveforms. The 254TXX is ideal for low, medium and high voltage applications and provides a high protection against continuous and short circuit protection as well as galvanically isolated inputs and outputs - True rms measurement - User programmable configuration - Linear or Dual Slope Outputs - User friendly programming interface ENERGY / CROMPTON INSTRUMENTS TRANSDUCER ## **DIMENSIONAL INFORMATION** **==> picture [417 x 140] intentionally omitted <==** **----- Start of picture text -----**<br> Product selection<br>Product Code Outputs Auxiliary<br>254-TXX-M-2-030 2x Analogue, USB<br>254-TXX-M-2-070 2x Analogue, Ethernet 100-250V AC/DC<br>254-TXX-M-4-030 4x Analogue, USB<br>es<br>254-TXX-M-4-070 4x Analogue, Ethernet<br>PO<br>254-TXX-L-2-030 2x Analogue, USB<br>es<br>254-TXX-L-2-070 2x Analogue, Ethernet<br>PO —“(—“<‘i a 12-48V DC<br>254-TXX-L-4-030 4x Analogue, USB<br>es<br>254-TXX-L-4-070 4x Analogue, Ethernet<br>a<br>**----- End of picture text -----**<br> The Paladin 254-TXX is a programmable Transducer. For initial programming or reprogramming of an existing product please use the Crompton Instruments Transducer Configurator software. Make sure that you have the latest version of Transducer Configurator software installed on your computer. You can download the latest version at: ## **https://www.te.com/en/private/energy/crompton-software-downloads-254-TXX-programmabletransducer.html** ENERGY / CROMPTON INSTRUMENTS TRANSDUCER ## **WIRING DIAGRAMS** ## **SINGLE PHASE** ## **THREE PHASE THREE WIRE BALANCED LOAD** ## **THREE PHASE FOUR WIRE BALANCED LOAD** ## **THREE PHASE THREE WIRE UNBALANCED LOAD** ## **THREE PHASE FOUR WIRE UNBALANCED LOAD** ENERGY / CROMPTON INSTRUMENTS TRANSDUCER **==> picture [525 x 619] intentionally omitted <==** **----- Start of picture text -----**<br> Technical Specifications<br>Input<br>Nominal input voltage 57.7 V – 277 V AC L-N (100 – 480 V L-L) 480 V MAX<br>Max. Continuous input overload voltage 120% of nominal<br>Max. Short duration input voltage (300 msec) 2 x nominal voltage<br>Nominal input voltage burden < 0.1 VA per phase<br>Nominal input current 1A AC or 5A AC rms<br>Nominal input current burden < 0.1 VA per phase<br>Max. Continuous input overload current 2 x nominal current<br>Max. Short duration input current (300 msec) 20 x nominal current<br>Auxiliary<br>100 – 250 V AC/DC (+/- 20%) 45 – 66 Hz or<br>Operating range 12 – 48 V AC/DC (+/- 20%)<br>Supply burden <15VA / <5VA<br>Accuracy<br>Voltage (V) < 0.2%<br>Current (A) < 0.2%<br>Neutral current calculated (A) < 1.0%<br>Frequency (Hz) < 0.1 Hz<br>Power factor (PF) 1% of unity<br>Active power (W) +/- 0.2% of range<br>Reactive power (VAr) +/- 0.2% of range<br>Apparent power (VA) +/- 0.2% of range<br>Active energy (kWh) Class 0.2 (IEC 62053-21)<br>Reactive energy (kVArh) +/- 0.2% of range<br>Response time <200 msec<br>Range<br>Voltage (V) 5% to 120% for nominal<br>Current (A) 5% to 120% of nominal<br>Frequency 45 – 65 Hz<br>THD 2% up to 63rd harmonic<br>Outputs<br>0... +/- 1 mA 0... +/- 1 V<br>0... +/- 5 mA 2... +/- 10 V<br>0... +/- 10 mA<br>Analogue output 0... +/- 20 mA<br>4... +/- 20 mA<br>All programmable<br>Pulse/alarm output relay User defined solid state relay<br>Contact rating 100 mA @ 50 V<br>Pulse duration 20 msec to 300 msec<br>Alarm delay 0 – 120 secs<br>Alarm hysteresis 1 – 99%<br>Alarm type User Defined Solid State Relay<br>Communication protocol RS485 Modbus RTU (USB / Ethernet Options)<br>Type 2-wire half duplex<br>Baud rate 2400, 4800, 9600, 19200, 38400<br>Enclosure<br>Enclosure style DIN-rail mounting<br>Dimensions 120(H) x 100(W) x 70(D) mm<br>Material Polycarbonate to UL94-V0<br>Weight 0.50 kg<br>Terminals Shrouded screw-clamp 0.05 – 4 mm wire<br>Environment<br>Operating temperature -10°C to +55°C<br>Storage temperature -30°C to +70°C<br>Relative humidity 0 – 90% non-condensing<br>Shock 30 g in 3 planes<br>Vibration 10 Hz to 50 Hz<br>Withstand test 4 kV, 50 Hz for 1 minute between<br>Dielectric voltage<br>auxiliary/input/output<br>**----- End of picture text -----**<br> **ENERGY / CROMPTON INSTRUMENTS TRANSDUCER** ## **PARAMETERS** **==> picture [525 x 36] intentionally omitted <==** **----- Start of picture text -----**<br> Parameters<br>Parameter Description Analogue Output<br>**----- End of picture text -----**<br> |Parameters|Parameters|Parameters| |---|---|---| |**Parameter**|**Description**|**Analogue Output**| |||| |V1|Phase 1 Voltage|ü| |V2|Phase 2 Voltage|ü| |V3|Phase 3 Voltage|ü| |I1|Phase 1 Current|ü| |I2|Phase 2 Current|ü| |I3|Phase 3 Current|ü| |W1|Phase 1 Watts|ü| |W2|Phase 2 Watts|ü| |W3|Phase 3 Watts|ü| |Var1|Phase 1 Vars|ü| |Var2|Phase 2 Vars|ü| |Var3|Phase 3 Vars|ü| |VA1|Phase 1 VA|ü| |VA2|Phase 2 VA|ü| |VA2|Phase 3 VA|ü| |VLL12|Phase 1-2 Voltage|ü| |VLL23|Phase 2-3 Voltage|ü| |VLL31|Phase 3-1 Voltage|ü| |PF1|Power Factor Phase 1|ü| |PF2|Power Factor Phase 2|ü| |PF3|Power Factor Phase 3|ü| |PA1|Phase Angle Phase 1|ü| |PA2|Phase Angle Phase 2|ü| |PA3|Phase Angle Phase 3|ü| |VLN Avg|Average L/N Voltage|ü| |VLL Avg|Average L/L Voltage|ü| |I Sum|System Current Total|ü| |I Avg|Average System Current|ü| |W Sum|System Power Total|ü| |VAr Sum|System Reactive Power Total|ü| |VA Sum|System VA Total|ü| |Sys Hz|System Frequency|ü| |PF Avg|System Power Factor|ü| |THD V1|Phase 1 V THD %|ü| |THD V2|Phase 2 V THD %|ü| |THD V3|Phase 3 V THD %|ü| |THD I1|Phase 1 I THD %|ü| |THD I2|Phase 2 I THD %|ü| |THD I3|Phase 3 I THD %|ü| **137 Further Electrical Parameters available through Modbus** ## crom ton-instruments.com p ## Learn more: TE.com/energy © 2024 TE Connectivity. All Rights Reserved. EPP-4523-DDS-10/25-245-TXX Connect with us: TE.com/energy TE, TE Connectivity, TE connectivity (logo), EVERY CONNECTION COUNTS, are trademarks owned or licensed by TE Connectivity. Other logos, product and company names mentioned herein may be trademarks of their respective owners. While TE has made every reasonable effort to ensure the accuracy of the information in this brochure, TE does not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any time without notice. TE Connectivity’s obligations shall only be as set forth in TE Connectivity’s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions, specifications, and/or information contained herein are for reference purposes only and are subject to change without notice. Consult TE for the latest dimensions, specifications, and/or information. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. **ENERGY / CROMPTON INSTRUMENTS TRANSDUCER**
Updated at April 23, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →