2210-T210-K0M1-H121-16A
Thermal Magnetic Circuit Breaker, IP20, IP30, 2210 Series, 16 A, 1 Pole, 65 V, 433 V, DIN Rail
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: ETA
- Product type: Thermal Magnetic Circuit Breakers
- SVHC: No SVHC (17-Jan-2022)
- No. of Poles: 1 Pole
- Product Range: 2210 Series
- Current Rating: 16A
- Voltage Rating VAC: 433V
- Voltage Rating VDC: 65V
- Circuit Breaker Mounting: DIN Rail
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 34.37 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Thermal-Magnetic Circuit Breaker 2210-T2..** ## **Description** One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Featuring a combi-foot design for both symmetric and asymmetric rail mounting. Available with auxiliary contact (1 x N/O or 1 x N/C) for status signalling. Two and three pole models are internally linked to ensure that both/all poles trip in the event of an overload on one pole, even if the actuator is held in the ON position. This CBE can be supplied in current ratings up to 32 A with a choice of characteristic curves. All screw terminals are recessed for safety. Approved to CBE standard EN 60934 (IEC 60934). ## **Typical applications** LO **==> picture [45 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> 2210-T2..<br>2-pole<br>**----- End of picture text -----**<br> Process control equipment, robotics, machine tool control, communications systems, instrumentation. ## **Features** eee - l Comprehensive approvals allow global use - l Current rating range from 0.1 A to 32 A - l Very small width of only 12.5 mm including auxiliary contacts - l High vibration resistance to DNV GL Class B for mounting with combustion engines, pumps, compressors ## **Your benefits** - l Space and weight savings of at least 50 % compared to conventional MCBs - l Reduced assembly times thanks to integral auxiliary contacts - l Optimum equipment protection through fine grading of current ratings - l Compliant with the relevant requirements of the railway standards DIN EN 50155, DIN EN 61373 and EN 45545 (detailed information upon request) ## **Preferred types – for more details on all configurations please see order numbering code** Preferred types are E-T-A products most frequently used by E-T-A customers. We manufacture E-T-A preferred types in particularly high volumes. Our preferred types are supplied at shorter lead times than non-standard versions. |**Preferred types**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**| |---|---|---|---|---|---|---|---|---|---|---|---| |**1-pole**|**0.5**|**1**|**2**|**3**|**4**|**5**|**6**|**8**|**10**|**16**|**20**| |2210-T210-K0M1-H121-|x|x|x|x|x|x|x|x|x|x|x| |**2-pole**|**0.5**|**1**|**2**|**3**|**4**|**5**|**6**|**8**|**10**|**16**|**20**| |2210-T220-K0M1-H221-|||x||x||x||x|x|x| ## **Approvals** eee, ## **Data sheet** For access to the latest documents please follow:www.e-t-a.de/en053 **Compliances** Lo **www.e-t-a.de** 2011 1 **Thermal-Magnetic Circuit Breaker 2210-T2..** ## **Technical data** |**Technical data**|**Technical data**|**Technical data**| |---|---|---| |**For further detailsplease see: www.e-t-a.de/ti_e**||| |Voltage rating<br>AC 250 V; 3 AC 433 V (50/60 Hz); DC 65 V<br>(UL: AC 277/480 V;DC 65 V)||| |Current rating range<br>0.1...32 A for curves M1, T1<br>0.1...16 A for curves F1,F2||| |Auxiliary circuit<br>1 A, AC 240 V / DC 65 V, resistive<br>(min. 10 V / 10 mA)||| |Typical life<br>3 AC 433 V; AC 250 V:<br>0.1...25 A<br>10,000 operations at 1 x IN, inductive<br>DC 65 V:<br>0.1...32 A<br>10,000 operations at 1 x IN, inductive<br>3 AC 433 V; AC 250 V:<br>32 A<br>6,000 operations at 1 x IN,resistive||| |Ambient temperature -30...+60 °C(-22...+140 °F)T 60||| |Insulation co-ordination rated impulse<br>pollution<br>(IEC 60664 and 60664 A) withstand voltage<br>degree<br>2.5 kV<br>2<br>reinforced insulation in operatingarea||| |Dielectric strength<br>(IEC 60664 and 60664A) test voltage<br>operating area<br>AC 3,000 V<br>main/aux. circuit<br>AC 3,000 V<br> pole/pole<br>AC 1,500 V||| |Insulation resistance<br>> 100 MΩ(DC 500 V)||| |Interrupting capacity Icn<br>0.1...5 A 400 A<br>6...32 A<br>800 A<br>curves F1, F2, M1, T1:<br>0.1...16 A 2,500 A (at DC 32 V)||| |Interrupting capacity (UL 1077)||| |**IN**|**0.1...16 A**|**20...32 A**| |AC 277 V_1-pole_|5,000 A|2,000 A| |AC 277/480 V_2-/3-pole_|5,000 A|2,000 A| |DC 65 V|2,000 A|2,000 A| |Degree of protection<br>operating area IP30<br>(IEC 60529/DIN 40050)terminal area IP20||| |Vibration curves F1, F2: 3 g (57-500 Hz), ± 0.23 mm (10-57 Hz)<br>curves M1, T1: 5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)<br>to IEC 60068-2-6, test Fc<br>10 frequencycycles/axis||| |Shock<br>curves F1, F2: 25 g (11 ms), directions 1, 2, 3, 4, 5<br>10 g (11 ms), direction 6<br>curves M1, T1: 25 g (11 ms), directions 1, 2, 3, 4, 5<br>20 g (11 ms), direction 6<br>to IEC 60068-2-27,test Ea||| |Corrosion<br>96 hours at 5 % salt mist<br>to IEC 60068-2-11,test Ka||| |Humidity<br>240 hours at 95 % RH<br>to IEC 60068-2-78,test Cab||| |Mass<br>approx. 60g perpole||| ## **Standard current ratings and typical internal resistance values** |**Current rating (A)**|**Internal resistance (Ω)**|**Internal resistance (Ω)**|**Internal resistance (Ω)**|**Internal resistance (Ω)**| |---|---|---|---|---| ||**F1**|**F2**|**M1**|**T1**| ||fast acting<br>for DC only|fast acting<br>delay for<br>AC + DC|standard for<br>AC+DC|delayed low<br>resistance<br>for AC only| |0.1|162|162|92|81| |0.2|39.3|39.3|26.1|24.2| |0.3|17.5|17.5|11.6|10.4| |0.4|9.2|9.2|6.6|6.0| |0.5|6.8|6.8|4.1|3.9| |0.6|4.2|4.2|3|2.7| |0.8|2.8|2.8|1.65|1.53| |1|1.6|1.6|1.10|0.98| |1.5|0.78|0,78|0.47|0.42| |2|0.42|0,42|0.28|0.24| |2.5|0.26|0.26|0.183|0.17| |3|0.18|0.18|0.124|0.12| |4|0.12|0.12|0.077|0.073| |5|0.092|0.092|0.063|0.055| |6|0.054|0.054|0.045|0.039| |8|0.025|0.025|≤ 0.02|≤ 0.02| |10|0.022|0.02|≤ 0.02|≤ 0.02| |12|≤ 0.02|≤ 0.02|≤ 0.02|≤ 0.02| |16|≤ 0.02|≤ 0.02|≤ 0.02|≤ 0.02| |20|-|-|≤ 0.02|≤ 0.02| |25|-|-|≤ 0.02|≤ 0.02| |32|-|-|≤ 0.02|≤ 0.02| ## **Approvals** |**Authority**|**Standard**|**Rated voltage**|**Current ratings**| |---|---|---|---| |VDE|IEC/EN<br>60934|3 AC 433 V<br>AC 250 V<br>DC 65 V|0.1 A…32 A<br>0.1 A…32 A<br>0.1 A…32 A| |UL|UL 1077|AC 277/480 V<br>AC 277 V<br>DC 65 V|0.1 A…32 A<br>0.1 A…32 A<br>0.1 A…32 A| |CSA|C22.2 No<br>235|AC 277/480 V<br>AC 277 V<br>DC 65 V|0.1 A…32 A<br>0.1 A…32 A<br>0.1 A…32 A| |CQC|GB 17701|AC 250/433 V<br>AC 250 V<br>DC 65 V|0.1 A…32 A<br>0.1 A…32 A<br>0.1 A…32 A| |DNV GL|IEC 60934,<br>DNVGL-<br>CG 0339|3 AC 433 V<br>AC 250 V<br>DC 65 V|0.1 A…32 A<br>0.1 A…32 A<br>0.1 A…32 A| |KTL|KC60934|AC 250 V, 1-pole<br>AC 433 V, 2-pole|0.1 A...16 A<br>0.1 A...16 A| **www.e-t-a.de** 2 2011 ## **Thermal-Magnetic Circuit Breaker 2210-T2..** ## **Preferred types** Preferred types are E-T-A products most frequently used by E-T-A customers. We manufacture E-T-A preferred types in particularly high volumes. Our preferred types are supplied at shorter lead times than non-standard versions. |**Preferred types**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**| |---|---|---|---|---|---|---|---|---|---|---|---| |**1-pole**|**0.5**|**1**|**2**|**3**|**4**|**5**|**6**|**8**|**10**|**16**|**20**| |2210-T210-K0M1-H121-|x|x|x|x|x|x|x|x|x|x|x| |**2-pole**|**0.5**|**1**|**2**|**3**|**4**|**5**|**6**|**8**|**10**|**16**|**20**| |2210-T220-K0M1-H221-|||x||x||x||x|x|x| ## **Ordering information** |**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |**Type No.**|||||||||||||||||||||| |**2210**||single and multipole thermal-magnetic circuit breaker|||||||||||||||||||| |||**Mounting**|||||||||||||||||||| |||**T**|rail mounting||||||||||||||||||| |||<br> <br> <br> <br> <br>|**Actuator design**||||||||||||||||||| ||||**2**|toggle|||||||||||||||||| ||||<br> <br> <br>|**Number of poles**|||||||||||||||||| |||||**1**||single pole protected|||||||||||||||| |||||**2**||2-pole protected|||||||||||||||| |||||**3**||3-pole protected|||||||||||||||| |||||<br>|<br>|**Accessories**|||||||||||||||| |||||||**0**||without accessories|||||||||||||| |||||||||**Terminal design (main contacts)**|||||||||||||| |||||||||**K0**||screw terminals|||||||||||| |||||||||||**Characteristic curve**|||||||||||| |||||||||||**F1**||fast acting: therm.1.01-1.4xIN;<br>magn.2-4xI~~N~~DC (DC only)|||||||||| |||||||||||**F2**||fast acting: therm.1.01-1.4xIN;<br>magn.3,5-6,5xI~~N~~AC/4,5-8,5xI~~N~~DC|||||||||| |||||||||||**M1**||standard delay: therm. 1.01-1.4xIN;<br>magn. 6-12xI~~N~~AC, 7.8-15.6xI~~N~~DC|||||||||| |||||||||||**T1**||delayed: therm. 1.01-1.4xI~~N~~; magn. 10-20xI~~N~~AC|||||||||| |||||||||||||**Auxiliary contact design**|||||||||| |||||||||||||**H**||without intermediate position|||||||| |||||||||||||||**Auxiliary contacts**|||||||| |||||||||||||||**1**||with auxiliary contacts|||||| |||||||||||||||**2**||auxiliary contacts on pole 1 only<br>(multipole devices)|||||| |||||||||||||||||**Auxiliary contact function (see diagrams)**|||||| |||||||||||||||||**2**||1 N/O contact|||| |||||||||||||||||**3**||1 N/C contact|||| |||||||||||||||||||**Auxiliary contact- terminal design**|||| |||||||||||||||||||**1**||screw terminals|| |||||||||||||||||||||**Current ratings**|| |||||||||||||||||||||**0.1...32 A**|| ||||||||||||||||||||||| **2210 - T 2 1 0 - K0 M1- H 1 2 1 - 10 A** ordering example **Please be informed that we have minimum ordering quantities to be observed.** ## **Custom designed versions** Looking for a version you cannot find in our ordering number code? Please get in touch. We will be pleased to find a solution for you. **www.e-t-a.de** 2011 3 ## **Thermal-Magnetic Circuit Breaker 2210-T2..** ## **Dimensions** ## **Internal connection diagrams** **==> picture [512 x 485] intentionally omitted <==** **----- Start of picture text -----**<br> 37.5<br>1.48 ...-H131-...<br>30.5<br>toggles linkedfor multipole 1.7745 slot fitting labels fromPhoenixWeidmüller 1.20.98425 0OFF positionI line1 (Si)11 N/C contact 0ON positionI line1 (Si)11<br>devices 20 Wieland 18<br>.787 .709<br>12 12<br>OFF ON (Si) (Si)<br>I > I ><br>11.5 2 2<br>9-12 .453 ...-H121-...<br>.354-.472<br>line (Si) N/O contact line (Si)<br>0 I 1 13 0 I 1 13<br>Si Si<br>12-14 1 2<br>.472-.551<br>14 14<br>(Si) (Si)<br>I > I ><br>12.5 12.5<br>.492 .492 2 2<br>42.5 40<br>1.67 1.57<br>G-profile symmetric rail main contact terminal Shock directions<br>EN 50035-G32 EN 50022-35x7.5 max. 6 mm [2] (AWG 10)<br>EN 50022-35x15/1.5 (rigid conductor)<br>tightening torque 0.5 Nm<br>Si-terminal M3<br>max. 1.5 mm [2] (AWG 16) (rigid conductor) 5 6<br>tightening torque 0.5 Nm 1<br>unit III 2<br>unit II<br>unit I<br>3<br>Cable cross section 4<br>Conductor Main contacts 1 & 2 Aux. contact IN<br>min. 0.2 mm² 0.2 mm²<br>rigid<br>max. 6 mm² 1.5 mm²<br>min. 0.2 mm² 0.2 mm²<br>flexible<br>max. 4 mm² 1.0 mm²<br>flexible with wire end ferrule min. 0.25 mm² 0.25 mm²<br>without plastic sleeve max. 4 mm² 1.0 mm²<br>flexible with wire end ferrule min. 0.25 mm² 0.25 mm²<br>with plastic sleeve max. 2.5 mm² 0.75 mm²<br>11.5 .453<br>78.5 3.09 88.5 3.48<br>44 1.73<br>12 .472 15 .591<br>5.5 .217 7.5 .295<br>M1 12A 12.5 .492<br>M1 12A<br>5.5 .217<br>M1 12A<br>**----- End of picture text -----**<br> ## **Installation drawing** **==> picture [249 x 174] intentionally omitted <==** **----- Start of picture text -----**<br> operating area<br>(reinforced insulation)<br>Si Si<br>1 2<br>mounting area<br>**----- End of picture text -----**<br> This is a metric design and millimeter dimensions take precedence ~~(~~[mm ] inch ~~)~~ **www.e-t-a.de** 4 2011 **Thermal-Magnetic Circuit Breaker 2210-T2..** ## **Typical time/current characteristics** **==> picture [169 x 604] intentionally omitted <==** **----- Start of picture text -----**<br> -F1 0.1…16 A DC only<br>10000<br>1000<br>100<br>10<br>1<br>0.1<br>0.01<br>0.001<br>1 2 4 6 8 10 20 406080100<br>… times rated current<br>-F2 0.1…7.5 A AC/ DC 1)<br>10000<br>1000<br>100<br>10<br>1<br>0.1<br>0.01<br>0.001<br>1 2 4 6 8 10 20 406080100<br>… times rated current<br>-F2 8…16 A AC/ DC 1)<br>10000<br>1000<br>100<br>10<br>1<br>0.1<br>0.01<br>0.001<br>1 2 4 6 8 10 20 40 6080100<br>… times rated current<br> +60 °C +23 °C -30 °C<br>+140 °F +73.4 °F -22 °F<br>Trip time in seconds<br>Trip time in seconds<br>Trip time in seconds<br>**----- End of picture text -----**<br> 1) Magnetic tripping currents are increased by 30% on DC supplies. **www.e-t-a.de** 2011 5 **Thermal-Magnetic Circuit Breaker 2210-T2..** ## **Typical time/current characteristics** **==> picture [512 x 485] intentionally omitted <==** **----- Start of picture text -----**<br> -M1 0.1…6 A AC/DC 1) -M1 8…32 A AC/DC 1)<br>10000 10000<br>1000 1000<br>100 100<br>10 10<br>1 1<br>0.1 0.1<br>0.01 0.01<br>0.001 0.001<br>1 2 4 6 8 10 20 40 6080100 1 2 4 6 8 10 20 40 6080100<br>… times rated current … times rated current<br>-T1 0.1…6 A AC only -T1 8…32 A AC only<br>10000 10000<br>1000 1000<br>100 100<br>10 10<br>1 1<br>0.1 0.1<br>0.01 0.01 60 °C<br> 23 °C<br>-30 °C<br>0.001 0.001<br>1 2 4 6 8 10 20 40 6080100 1 2 4 6 8 10 20 40 6080100<br>… times rated current … times rated current<br>The time/current characteristic curve depends on the ambient temperature Multi pole devices: all poles symmetrically loaded. With single pole overload,<br>prevailing. In order to eliminate nuisance tripping, please multiply the circuit thermal tripping will be at max. 1.7 x IN with curves F1, F2 and M1.<br>breaker current ratings by the derating factor shown below. See also section<br>Technical information. 1) Magnetic tripping currents are increased by 30 % on DC supplies<br> (curves F2, M1).<br>Ambient °F -22 -4 +14 +32 +73.4 +86 +104 +122 +140<br>temp. °C -30 -20 -10 0 +23 +30 +40 +50 +60<br>Derating factor 0.76 0.79 0.83 0.88 1 1.04 1.11 1.19 1.29<br>Trip time in seconds Trip time in seconds<br>Trip time in seconds Trip time in seconds<br>**----- End of picture text -----**<br> **www.e-t-a.de** 6 2011 ## SETA **Thermal-Magnetic Circuit Breaker 2210-T2.. Accessories** ~~a~~ **==> picture [109 x 15] intentionally omitted <==** **----- Start of picture text -----**<br> Plug-on cap , busbar 2/3-pole<br>Y 308 506 01<br>**----- End of picture text -----**<br> **==> picture [505 x 679] intentionally omitted <==** **----- Start of picture text -----**<br> Connector bus links -K10 Plug-on cap , busbar 2/3-pole<br>X210 589 01/ 2.5 mm [2] , (AWG 14) (black) up to 20 A max. load Y 308 506 01<br>X210 589 02/ 1.5 mm [2] , (AWG 16) (brown) up to 13 A max. load<br>ø2.5<br>50 pin lugs to<br>DIN 46230 .099<br>tinned copper Hak<br>Busbar 3-pole<br>Y 308 500 01<br>cross section: 16 mm²<br>AU<br>Busbar 1-pole, 90° X 222 540 11 The one metre long busbars can be cut to suitable lengths.Plug-on caps can be fitted on the ends to provide brush Y30850001 16 mmL1 2 L2GD-90518 AltdorfMade in GermanyE R M AL3N Y L1 L2 L3 L1 4051030L2 [+.787] L2 [+2] L3 L1 L2 L3 L1 L2 L3 ° 15.86.22<br>contact protection. cross section: 16 mm² 14.7 booed<br>5.79<br>3±0.2 1.5<br>i RECUELAEEEAEEL 1.81±.079 12.7 Li .591<br>5 80 x 12.7 = 1016<br>|i 1.813±0.2±.079 12.7 .5901.5 31.5 x 5 = 400<br>4 RERRRARROOED 5 79 x 12.7 = 1003.331.1 x 5 = 3950 | Plug-on capY 308 506 01 4 , busbar 2/3-pole<br>X22254011 16 mm2 GD-90518 AltdorfMade in GermanyE R M A N Y X22254011 16 mm2 GD-90518 AltdorfMade in GermanyE R M A N Y<br>1016 [+2]<br>400 [+.787]<br>Busbar 1-pole Y 308 498 01 Supply terminal<br>cross section: 16 mm² Y 308 503 01<br>1016 [+2] 4.6 Imax 63 A with 1-pole busbar,<br>400 [+.787] 1.81 50 A with multipole busbar<br>Y30849801 16 mm2 GD-90518 AltdorfMade in GermanyE R M A N Y Y30849801 16 mm2 GD-90518 AltdorfMade in GermanyE R M A N Y Max. tightening torque of terminal screw 2 NmMax. cable cross section: 25 mm [2] / single strand<br>16 mm [2] / multistrand<br>with wire end ferrule<br>PTUTT 1.813±0.2±.079 12.7 .5911.5 .1183 .0591.5<br>5 79 x 12.7 = 1003.3<br>31.1 x 5 = 3950<br>Busbar for 1-pole devices<br>Firmly mounted supply terminals, placed at fixed distances<br>(1 supply terminal every 7 modules)For cable feed from the side TTT TT 1 a .51213 b 18.4.724<br>Ideal for applications with high vibration requirements<br>Y31270901 cross section: 16 mm²<br>1012.8 [+2]<br>399 [+.787]<br>Y31270901 16 mm2 GD-90518 AltdorfMade in GermanyE R M A N Y Y31270901 16 mm2 GD-90518 AltdorfMade in GermanyE R M A N Y<br>79x12.7=1003,3<br>12.7 31.1 x 5 = 3950 3 1.5<br>UE 5 1.18 | .591 «RP Sea<br>76.2<br>30 12x76.2=914.4 | 23.5 =e<br>9.25<br>4.72x30=360<br>Plug-on cap , 1-pole<br>Y 307 851 01<br>Oh Caution:<br>When using multipole busbars please leave at least one pole’s<br>Busbar 2-pole<br>Y 308 499 01 cross section: 16 mm² width between two adjacent line entry terminals.<br>1016 [+2]<br> 15.8<br>400 [+.787] 6.22<br>Y30849901 16 mmL1 2 L2 GD-90518 AltdorfMade in GermanyE R M AL1N Y L2 L1 L2 L1 L2 L1 L2 L1 L2 L1 L2 L1 L2<br>UTE T Uy This is a metric design and millimeter dimensions take precedence ( - [mm ] inch )<br>3±0.2<br>12.75 TUT 1.81±.079 79x12.7 = 1003.3 ee .5911.5 All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications performance and cost effectiveness the right to make changes in these specifications<br>4.72x30=360 without notice is reserved.Product markings may not be exactly as the ordering codes.<br>~70 ~2.76<br>-1 -.394 ±0.4 ±.157<br>16 6.30 16 17.3 6.81 33.3 13.1<br>4.6 1.81<br>-1 -394<br>20 7.87<br>±0,4 ±.157<br>30,7 12.1<br>14.7 5.79<br>16 6.30<br>16.2 .638<br>33.7 1.327<br>35 13.8<br>±0.4 ±.157<br>33.3 13.1 17.3 6.81<br>16 6.30<br>Made in GermanyY D-90518 AltdorfN A M R E G Y30850001 216 mm<br>L3 L2 L1 L3 L2 L1 L3 L2 L2 L1 L3 L2 L1 L3 L2 L1<br>Made in GermanyY D-90518 AltdorfN A M R E G Y30849901 216 mm<br>L2 L1 L2 L1 L2 L1 L2 L1 L2 L1 L2 L1 L2 L1 L2 L1<br>**----- End of picture text -----**<br> All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. **www.e-t-a.de** 2011 7
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →