Image not available
Illustrative purposes only
209159
PRESSURE SWITCH, SPDT, 100PSI
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: GEMS SENSORS
- Product type: Pressure Switches
- Pressure Type:-; Pressure Port Type:NPT Male; Operating Pressure Min:25psi; Operating Pressure Max:100psi; Contact Configuration:SPDT; Switching Voltage Max:250VAC; Swit 42M0464
- Deadband Max: -
- Deadband Min: -
- Product Range: -
- Pressure Port Size: 1/4"
- Pressure Port Type: NPT Male
- Contact Configuration: SPDT
- Operating Pressure Max: 100psi
- Operating Pressure Min: 25psi
- Transducer Connection / Termination: Cable Clamp
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 55.63 € |
| Current stock | 10+ |
| Lead time | 30 days |
## PS41 – Economical Miniature Pressure Switches
## 3.5 to 100 psi (0.24 to 7 bar)
These miniature pressure switches are designed for demanding applications where space and/or price are strong concerns. The switches utilize a piston/diaphragm design, which incorporates the high proof pressure of piston technology with the sensitivity of diaphragm designs. Switches are field adjustable via an Allen head screw that is hidden to protect against unauthorized tampering.
## Specifications
## Dimensions
**==> picture [562 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Switch|SPST; SPDT|FLYING LEAD|ø1.10˝|
|Repeatability|See Table 1|3/32˝ or|(ø28)|
|1/8˝ ALLEN|
|Oe|Wetted Parts|WRENCH|||
|Diaphragm Material|Nitrile (optional EPDM, Viton|[® ]|or Neoprene)|ADJUSTMENT|
|SCREW|
|Fitting|Brass (optional 316 Stainless Steel)|
|Electrical Termination|DIN 43650A IP65; Terminals IP00; Flying Leads IP65;|PRESSURE|1.58˝|
|Option IP: IP66; Conduit with Flying Leads IP65|PORT|(40)|RED, NO.|
|GREEN, NC.|
|Proof Pressure|350 psi (24 bar)|BLACK, COM.|
|ee|Burst Pressure|700 psi (48 bar)|aa|[[=]]|
|s|
|Approvals|CE, UL Approved units available|INGRESS PROTECTION OPTION (IP66)|
|Weight, Approximate|Brass: 0.3 lbs. (0.14 kg)|WITH FLYING LEADS FACTORY SET ONLY|ø1.25˝|
**----- End of picture text -----**<br>
**==> picture [188 x 170] intentionally omitted <==**
**----- Start of picture text -----**<br>
FLYING LEAD ø1.10˝<br>3/32˝ or (ø28)<br>1/8˝ ALLEN<br>WRENCH |<br>ADJUSTMENT<br>SCREW<br>PRESSURE 1.58˝<br>PORT (40) RED, NO.<br>GREEN, NC.<br>BLACK, COM.<br>aa [[=]]<br>INGRESS PROTECTION OPTION (IP66)<br>WITH FLYING LEADS FACTORY SET ONLY ø1.25˝<br>(ø32)<br>2.20˝<br>(56)<br>**----- End of picture text -----**<br>
Recommended Operating Temperature Limits
**==> picture [293 x 118] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Options Selected|
|No option,|
|Diaphragm Material|-RD or -RD and -G|-SP or -10A|
|-10A, -SP or -RD|
|15°F to 185°F|15°F to 250°F|15°F to 212°F|
|Nitrile|
|(-9°C to +85°C)|(-9°C to +121°C)|(-9°C to +100°C)|
|0°F to 185°F|0°F to 250°F|0°F to 212°F|
|Viton|[®]|
|(-18°C to +85°C)|(-18°C to +121°C)|(-18°C to +100°C)|
|-10°F to +185°F|-10°F to +250°F|-10°F to +212°F|
|EPDM|
|(-23°C to +85°C)|(-23°C to +121°C)|(-23°C to +100°C)|
|-10°F to +185°F|-10°F to +250°F|-10°F to +212°F|
|Neoprene|
|(-23°C to +85°C)|(-23°C to +121°C)|(-23°C to +100°C)|
**----- End of picture text -----**<br>
**==> picture [234 x 68] intentionally omitted <==**
**----- Start of picture text -----**<br>
DIN 43650A – MALE HALF ONLY - 1.10˝(28)<br>} -_<br>|<br>1.95˝ DIN<br>(50) 43650A<br>**----- End of picture text -----**<br>
Note: Switches may function below the cold temperature limit but the set points and deadband will increase. Consult factory for details.
## Electrical Switch Ratings
**==> picture [277 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Options Selected|AC|DC|
|No option or|-RD|5 amps @ 125/250 Volts|5 amps resistive,|
|3 amps inductive @ 28 Volts|
|-G|or|-RD|with|-G|1 amp @ 125 Volts|1 amp resistive,|
|0.5 amp inductive @ 28 Volts|
|-SP|without|-G|10.1 amps @ 125/250 Volts|—|
|-SP|with|-G|2 amps @ 125/250 Volts|—|
**----- End of picture text -----**<br>
**==> picture [61 x 27] intentionally omitted <==**
**----- Start of picture text -----**<br>
RIGHT ANGLE DIN (HNR)<br>ADJUSTMENT SCREW<br>UNDER CAP SCREW<br>**----- End of picture text -----**<br>
**==> picture [179 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
PRESSURE<br>DIN 43650-HNR PORT<br>B<br>2.80˝ fz fe<br>1.78˝<br>(71)<br>(45)<br>| |=a<br>2.14˝ 1.12˝ AF<br>-- (54) th o (28)<br>**----- End of picture text -----**<br>
= **I-9**
_**Visit www.GemsSensors.com for most current information.**_
**mInIaTURE**
## How To Order
Use the **Bold** characters from the chart below to construct a product code. Please reference Notes.
**PS41 -10 -4MNB -C -H -XX -XXXX 1 2 3 4 5 6**
## **1 Pressure Range Code**
Insert Pressure Range Code from Table 1, below.
## **2 Pressure Fitting[1]**
## Brass
- **-2MNB** = 1/8˝ NPTM
- **-4MNB** = 1/4˝ NPTM
- **-2MGB** = 1/8˝ BSPM (G type)
- **-4MGB** = 1/4˝ BSPM (G type)
- **-4MSB** = 7/16˝-20 SAE Male
- **-6MSB** = 9/16˝-18 SAE Male
## 316 Stainless Steel
- **-2MNS** = 1/8˝ NPTM
- **-4MNS** = 1/4˝ NPTM
- **-4MGS** = 1/4˝ BSPM (G type)
- **-4MSS** = 7/16˝-20 SAE Male
## **3 Circuit**
- **-A** = SPST/N.O.
- **-B** = SPST/N.C.
- **-C** = SPDT
## **4 Electrical Termination**
- **-SP** = Spade Terminals[2]
## **5 Options[7]**
- **-V** = Viton[®] Diaphragm
- **-N** = Neoprene Diaphragm
- **-E** = EPDM Diaphragm
- **-10A** = 10A @ 125/250 VAC Max. Rating
- **-G** = Gold Contacts
(for loads less than 12 mA @ 12 VDC)
- **-RD** = Reduced Differential
- (25% reduction typical)
- **-IP** = Ingress Protection[8]
- **-OXY** = Oxygen Cleaned
- **-WF** = Weather Pack Connector, Female
- **-WM** = Weather Pack Connector, Male
**-DE** = Deutsch Connector, Male, DT04 Series
## **6 Fixed Set Point (optional)**
A. Specify set point **-FS**
- (in PSI or BAR, see example)[9]
B. Set Point Actuation
- **R** on Rising Pressure
**F** on Falling Pressure Example: **-FS0.5BARF** for 0.5 BAR Falling or **-FS5PSIR** for 5 PSI Rising
Notes:
1. Other fittings available. Consult factory.
2. Requires **-10A** or **-G** option. (20% increase in deadband typical)
3. 18˝ is standard. Specify lead length in inches (max. 48˝). e.g. **-FL18** or **-FLS30** .
4. 18˝ is standard. Specify lead length in inches (max. 48˝). e.g. **-EL18** or **-EL30** .
5. 36˝ is minimum. Specify cable length in inches. e.g.
- **-CAB36** or **-CAB120** .
6. DIN connectors require **-C** SPDT circuit.
7. Options **-10A** , **-G** or **-RD** cannot be combined.
8. Ingress Protection is available only with **-FL** , **-FLS** or **-CAB** Electrical Termination choices. Ingress Protection requires Fixed Set Point **-FS** .
9. Set Point must be within Pressure Range selected in Step 1.
- **-FLXX** = Flying Leads[3]
- **-FLSXX** = Flying Leads w/PVC Shrink Tubing[3]
- **-ELXX** = 1/2˝ NPT Male Conduit w/Flying Leads[4]
- **-CABXX** = 18 AWG PVC Cable[5]
- **-H** = DIN 43650A Male Half Only[6]
- **-HR** = Right Angle DIN 43650A Male Half Only[6]
- **-HC** = DIN 43650A 9mm Cable Clamp[6]
- **-HCR** = Right Angle DIN 43650A 9mm Cable
Clamp[6]
- **-HN** = DIN 43650A with 1/2˝ Female NPT Conduit[6]
- **-HNR** = Right Angle DIN 43650A with 1/2˝ Female NPT Conduit[6]
Table 1 — Pressure Range Codes
**==> picture [524 x 18] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pressure Range Code Pressure Range Repeatability* Average Deadband**<br>**----- End of picture text -----**<br>
|**Pressure Range Code**|**Pressure Range**|**Repeatability***|**Average Deadband****|
|---|---|---|---|
|||||
|**10**|3.5-8 psi(0.24-0.55 bar)|±0.35 psi(0.024 bar)+2% of setting|1.50 psi(0.14 bar)+7% of setting|
|**20**|7-30 psi (0.48-2.07 bar)|±0.8 psi (0.055 bar) +2% of setting|3 psi (0.21 bar) +8% of setting|
|**30**|25-100 psi (1.7-6.9 bar)|±2.0 psi (0.138 bar) +2% of setting|5 psig (0.28 bar) +10% of setting|
* Repeatability and set point of units may change due to the effects of temperature.
** These numbers are for the standard microswitch. With either the -SP or -10A option, the values are typically 20% greater than those listed. With the -RD option, the values will be typically 25% less than those listed. In certain applications deadband can be tailored and controlled to customer specifications. Consult factory for details.
**I-10**
_**Visit www.GemsSensors.com for most current information.**_
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →