2014400000
Wire-To-Board Terminal Block, 12.7 mm, 4 Ways, 22 AWG, 6 AWG, 16 mm², Screw
- Manufacturer: WEIDMULLER
- Product type: Wire-To-Board Terminal Blocks
- SVHC: No SVHC (16-Jan-2020)
- Pitch Spacing: 12.7mm
- Product Range: OMNIMATE Power LUP
- Rated Current: 76A
- Rated Voltage: 1kV
- No. of Positions: 4Ways
- Block Orientation: Through Hole Right Angle
- Wire Size AWG Max: 6AWG
- Wire Size AWG Min: 22AWG
- Conductor Area CSA: 16mm²
- Wire Connection Method: Screw
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 8.74 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Data sheet** ~~Ly~~ **OMNIMATE Power - series LUP LUP 12.70/04/90 5.0SN BK BX**
**Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com
## **Product image**
Similar to illustration
This PCB terminal provides connections for 1000 V, 76 A and 16 mm² conductor cross-section with proven clamping yoke connection at 12.7 mm pitch, conductor outlet direction in 90° design.
## **General ordering data**
|Type|LUP 12.70/04/90 5.0SN BK BX|
|---|---|
|Order No.|2014400000|
|Version|Printed circuit board terminals, 12.70 mm,|
||Number of poles: 4, 90°, Solder pin length (l): 5|
||mm, tinned, black, Clamping yoke connection,|
||Clampingrange, max. : 16 mm², Box|
|GTIN(EAN)|4050118400199|
|Qty.|20pc(s).|
|Product data|IEC: 1000 V / 76 A / 0.5 - 16 mm²|
||UL: 600 V/65 A/AWG 22 - AWG 6|
|Packaging|Box|
Creation date September 9, 2020 10:04:26 AM CEST
Catalogue status 28.08.2020 / We reserve the right to make technical changes.
1
**Data sheet** — **OMNIMATE Power - series LUP LUP 12.70/04/90 5.0SN BK BX**
## **Technical data** ~~Ld~~
**Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com ~~a~~
## **Dimensions and weights**
|Width|49.06 mm|Width(inches)|1.931 inch|
|---|---|---|---|
|Height|36.5 mm|Height(inches)|1.437 inch|
|Height of lowest version|31.5 mm|Depth|25.1 mm|
|Depth (inches)|0.988 inch|Net weight|35 g|
|**System parameters**||||
|Product family|OMNIMATE Power - series|Wire connection method||
||LUP||Clamping yoke connection|
|Mountingonto the PCB|THT solder connection|Conductor outlet direction|90°|
|Pitch in mm(P)|12.7 mm|Pitch in inches(P)|0.5 inch|
|Number ofpoles|4|Fitted bycustomer|Yes|
|Max. adjacentpolesper row|12|Solderpin length(l)|5 mm|
|Solderpin dimensions|1.2 x 1.2 mm|Solder eyelet hole diameter(D)|1.6 mm|
|Solder eyelet hole diameter tolerance(D)<br>+ 0,1 mm||Number of solderpinsperpole|2|
|Screwdriver blade|1.0 x 5.5,PZ 2|Screwdriver blade standard|DIN 5264|
|Tighteningtorque,min.|1.2 Nm|Tighteningtorque,max.|1.5 Nm|
|Clampingscrew|M 4|Strippinglength|12 mm|
|L1 in mm|38.1 mm|L1 in inches|1.5 inch|
|Touch-safe protection acc. to DIN VDE|IP20 plugged/ IP10|Touch-safe protection acc. to DIN VDE||
|0470|unplugged|57 106|Safe from finger touch|
|Volume resistance|0.50 mΩ|||
|**Material data**||||
|Insulatingmaterial|Wemid(PA)|Colour|black|
|Colour chart(similar)|RAL 9011|Insulatingmaterialgroup|I|
|Comparative TrackingIndex(CTI)|≥ 600|UL 94 flammabilityrating|V-0|
|Contact material|E-Cu|Contact surface|tinned|
|Layer structure of solder connection|1.5...3 µm Ni / 4...6 µm Sn|Storage temperature, min.||
||matt||-40 °C|
|Storage temperature,max.|70 °C|Operatingtemperature,min.|-50 °C|
|Operatingtemperature,max.|120 °C|Temperature range,installation,min.|-25 °C|
|Temperature range, installation, max.|120 °C|||
## **Conductors suitable for connection**
|Clampingrange,min.|0.13 mm²|
|---|---|
|Clampingrange,max.|16 mm²|
|Wire connection cross section AWG,|AWG 22|
|min.||
|Wire connection cross section AWG,|AWG 6|
|max.||
|Solid,min. H05(07)V-U|0.5 mm²|
|Solid,max. H05(07)V-U|16 mm²|
|Stranded,min. H07V-R|6 mm²|
|Stranded,max. H07V-R|16 mm²|
|Flexible,min. H05(07)V-K|0.5 mm²|
|Flexible,max. H05(07)V-K|16 mm²|
|w. plastic collar ferrule, DIN 46228 pt 4,|2.5 mm²|
|min.||
|w. plastic collar ferrule, DIN 46228 pt 4,|10 mm²|
|max.||
|w. wire end ferrule, DIN 46228 pt 1,|2.5 mm²|
|min.||
Creation date September 9, 2020 10:04:26 AM CEST
Catalogue status 28.08.2020 / We reserve the right to make technical changes.
2
**Data sheet** — **OMNIMATE Power - series LUP LUP 12.70/04/90 5.0SN BK BX**
## **Technical data** ~~Ld~~
**Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com ~~a~~
|**Technical data**<br>~~Ld~~|||~~a~~|Fax: +49 5231 14-292083<br>www.weidmueller.com<br>~~a~~|Fax: +49 5231 14-292083<br>www.weidmueller.com<br>~~a~~|~~a~~|
|---|---|---|---|---|---|---|
|w. wire end ferrule, DIN 46228 pt 1,||10 mm²|||||
|max.|||||||
|Plug gauge in accordance with EN||5.4 mm x 5.1 mm; 5.3 mm|||||
|60999 a x b;ø|||||||
|Clampable conductor||Cross-section for conductor connection|Cross-section for conductor connection|Type|fine-wired||
|||||nominal|2.5 mm²||
||wire end ferrule<br>Strippinglength<br>nominal<br>12 mm<br>Recommended wire-<br>end ferrule<br>H2,5/12<br>Strippinglength<br>nominal<br>14 mm<br>Recommended wire-<br>end ferrule<br>H2,5/19D BL<br>Cross-section for conductor connection<br>Type<br>fine-wired<br>nominal<br>4 mm²<br>wire end ferrule<br>Strippinglength<br>nominal<br>12 mm<br>Recommended wire-<br>end ferrule<br>H4,0/12<br>Strippinglength<br>nominal<br>14 mm<br>Recommended wire-<br>end ferrule<br>H4,0/20D GR<br>Cross-section for conductor connection<br>Type<br>fine-wired<br>nominal<br>6 mm²<br>wire end ferrule<br>Strippinglength<br>nominal<br>12 mm<br>Recommended wire-<br>end ferrule<br>H6,0/12<br>Strippinglength<br>nominal<br>14 mm<br>Recommended wire-<br>end ferrule<br>H6,0/20 SW<br>~~ee~~<br>~~——~~<br>PF<br>~~} —___1___~~<br>~~——~~<br>PF<br>~~/}—______l__~~<br>~~——~~||||||
|||Cross-section for conductor connection<br>Type<br>fine-wired<br>nominal<br>10 mm²<br>wire end ferrule<br>Strippinglength<br>nominal<br>15 mm<br>Recommended wire-<br>end ferrule<br>H10,0/22 EB<br>Strippinglength<br>nominal<br>12 mm<br>Recommended wire-<br>end ferrule<br>H10,0/12<br>~~eee~~<br>~~/} —_____1____~~<br>~~=~~|||||
|Reference text||Length of ferrules is to be chosen depending on the product and the rated voltage., The outside|||||
|||diameter of theplastic collar should not be lar|lastic collar should not be larger than the|er than thepitch(P)|||
|Max. clamping range||16 mm²|||||
|**Rated data acc. to IEC**|||||||
|tested acc. to standard|||Rated current, min. number of poles||||
|||IEC 60664-1,IEC 61984|(Tu=20°C)||76 A||
|Rated current, max. number of poles|||Rated current, min. number of poles||||
|(Tu=20°C)||74 A|(Tu=40°C)||76 A||
|Rated current, max. number of poles|||Rated voltage for surge voltage class /||||
|(Tu=40°C)||64 A|pollution degree II/2||1,000 V||
|Rated voltage for surge voltage class /|||Rated voltage for surge voltage class /||||
|pollution degree III/2||1,000 V|pollution degree III/3||1,000 V||
|Rated impulse voltage for surge voltage|||Rated impulse voltage for surge voltage||||
|class/ pollution degree II/2||6 kV|class/ pollution degree III/2||8 kV||
|Rated impulse voltage for surge voltage|||Short-time withstand current resistance||||
|class/ contamination degree III/3||8 kV|||1 x 1s with 700 A||
|**Rated data acc. to CSA**|||||||
|Rated voltage(UsegroupB/CSA)||600 V|Rated voltage(Use|UsegroupC/CSA)|600 V||
|Rated current(UsegroupB/CSA)||65 A|Rated current(Use|UsegroupC/CSA)|65 A||
|Wire cross-section, AWG, min.||AWG 22|Wire cross-section, AWG, max.||AWG 6||
Creation date September 9, 2020 10:04:26 AM CEST
Catalogue status 28.08.2020 / We reserve the right to make technical changes.
3
**Data sheet**
## **OMNIMATE Power - series LUP LUP 12.70/04/90 5.0SN BK BX**
## **Technical data** ~~Ss~~
**Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com
## **Rated data acc. to UL 1059**
Institute (cURus) Certificate No. (cURus) clus E60693 Rated voltage (Use group B / UL 1059) 600 V Rated voltage (Use group C / UL 1059) 600 V Rated current (Use group B / UL 1059) 65 A Rated current (Use group C / UL 1059) 65 A Wire cross-section, AWG, min. AWG 22 Wire cross-section, AWG, max. AWG 6 Reference to approval values Specifications are maximum values, details - see approval certificate.
## **Packing**
Packaging Box VPE length 0 m VPE width 0 m VPE height 0 m **Classifications** ETIM 6.0 EC002643 ETIM 7.0 EC002643 eClass 9.0 27-44-04-01 eClass 9.1 27-44-04-01 eClass 10.0 27-44-04-01
## **Notes**
- Notes • Additional colours on request
- Rated current related to rated cross-section & min. No. of poles.
- Wire end ferrule without plastic collar to DIN 46228/1
- Wire end ferrule with plastic collar to DIN 46228/4
- The data given under CSA relates to a cUL approval - E60693
- P on drawing = pitch
- Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards.
- Long term storage of the product with average temperature of 50 °C and average humidity 70%, 36 months
IPC conformity
Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 "Class 2". Further claims on the products can be evaluated on request.
## **Approvals**
Approvals
ROHS Conform
Creation date September 9, 2020 10:04:26 AM CEST
Catalogue status 28.08.2020 / We reserve the right to make technical changes.
4
**Data sheet** — **OMNIMATE Power - series LUP LUP 12.70/04/90 5.0SN BK BX**
## **Technical data** ~~Ld~~
**Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com ~~a~~
## **Downloads**
|Approval/Certificate/Document of||
|---|---|
|Conformity|Declaration of the Manufacturer|
|Brochure/Catalogue|FL DRIVES EN|
||MB DEVICE MANUF. EN|
||FL DRIVES DE|
||FL APPL_INVERTER EN|
||FL_BASE_STATION_EN|
||FL ELEVATOR EN|
||FL POWER SUPPLY EN|
||FL 72H SAMPLE SER EN|
||PO OMNIMATE EN|
|EngineeringData|EPLAN, WSCAD|
|EngineeringData|STEP|
|White paper power electronics||
|connected correctly|Download Whitepaper|
|User Documentation|QR-Code product handling video|
|White paper UL 600 V|Download Whitepaper|
Creation date September 9, 2020 10:04:26 AM CEST
Catalogue status 28.08.2020 / We reserve the right to make technical changes.
5
**Data sheet**
## **OMNIMATE Power - series LUP LUP 12.70/04/90 5.0SN BK BX**
## **Drawings**
**Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com
## **Dimensional drawing**
**Graph**
**Graph**
Creation date September 9, 2020 10:04:26 AM CEST
Catalogue status 28.08.2020 / We reserve the right to make technical changes.
6
Dimensions without tolerances are no check dimensions
= 2 ss se ae ~= LE25 35 28 zs s32 SSE ez s S35 os = Ses SES Sa Ee a sos z36 2 ~e = é =° -_ ex et 23 == ss 32 86 s =
**==> picture [804 x 808] intentionally omitted <==**
**----- Start of picture text -----**<br>
The English version is binding<br>PS 2.0 / ORDER NO.<br>031000 0000<br>Ss<br>L1+10.16 & | S<br>L1+0.4" 0.8 ~<br>0.031" 25<br>LL fe n<br>as SS SS Ir<br>== SSS SS LS é m oo Y<br>ee ee ee mare foe op 1D ——_—_ .<br>eH LN J) aia ol"<br>a ; ico CONDUCTOR<br>! ! ! ! ee<br>(5.08) IL 1.2 | |<br>(O.2") L1 0.047" 10.16 2.85<br>0.4" O.11e" — .,.<br>0.839" a<br>Lt tt | ty ty! i a<br>.<br>Li .<br>2 L1 —<br>o> & oO a | TO MAINTAIN THE NECESSARY VOLTAGE DISTANCES<br>p ob» go p © 8 Ls ==| 2= FOR 600V - UL & 1000V - IEC,<br>S o»: a a S = i = | A SPACING PLATE IS REQUIRED BETWEEN ASSEMBLED<br>© 0) e l l ( e l = LUP 12.7 PCB TERMINAL BLOCKS<br>~-4------.-----{- ne ann<br>NO aw =e =\=<br>_ - - Ch _ - Oy -_ SPACING PLATE<br>fl fl f | — == ] == | E=<br>! = = al fel fa l = Tz] 159,70 5,500<br>HOLE PATTERN (BLOCK) HOLE PATTERN i SPACING PLATE<br>= ps | 88,90 | 6500 _|<br>SS | S I NGLE POL<br>-NO OF POLES = = e , = a eieie<br>teu va Fieli e l e | Si S i a i e fe [eso [2500<br>|= STIFTLAENGE/ 5.0mm/0.197" =i a le Stele S| 50,80 | 2,000<br>SHOWN:PIN L UPENGTH12.70/02/90...803.2mm/0.126!(BLOCK} Aleaes S e<br>LUP 12.70/03/90...80 (BLOCK) GENERAL TOLERANCE:<br>LUP 12.7/04/90... (SINGLE POL) DIN ISO 2768-mK SPACING PLATE [tommy [a [tt mm] 0 Ginen)<br>For the mounting of PCBs, it should be noted that the R .<br>rated data given in the catalogue relates only to the “?OMPLIANT | 102479 Prim PLM Part No.: 411688 Pri m ERP Part No.: 1160810000<br>connection elements. The neccessary creepage and ; = as a 3 4 1 6 3 1 0<br>lerane paths mus be observed in conection wi ist asue Date | Weidmiiller 22:05» sn<br>The current-carrying capacity and pitch tolerance is to 03.03.2018 Modification Sheet 02 of 02 sheets<br>be determined according to DIN IEC 326 part 3 very fine. Date Name<br>Weidmall t tested<br>standard,Provided thatand theare connectorsvalid {or itsare fieldusedtoofthe application,to DINthe VDEintended0627 ran Responsible DS OS POTD [AeninisiatorAmann, ini Alexand LUP1 2.70/../90 \&ee<br>purpose, all requirements with respect to the 9. vo \ x<br>occuring of electrical, mechanical, thermic and Scale: 2:1 Size: A3 | Approved 90<br>Corrosive stress will be satisiied. Drawings Assembly Product file: 7233 LUP 10.16/12.7 ,<br>**----- End of picture text -----**<br>
##
**Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com
## **Single Wave:**
**==> picture [432 x 446] intentionally omitted <==**
**----- Start of picture text -----**<br>
Contact time appr. 3 sec.<br>260 255 °C o s , 260 °C<br>240 250 °C I ~,.N\<br>\ [‘]<br>220 \\ [N] N [N] N<br>LON<br>200180 .\1\\ [.][N] SS\SsN.<br>160 \\\Str ‘\‘S‘S<br>wT “oy, “w<br>140 od° oNs\ "he,a> S.ss<br>12010080 Preheating :o.;7” .’Pua&&Pia4.-As-A.ue<ormeee7eeerrccCi7”Y11hae.~s- 7 appr. 150 °C \ny\\ny\\‘ wy£2.2>""y“ Cooling rate < 6 °K/s SS“>soy.‘s>“sDo~aTa“ss—m~. =~areTaaaooo-<br>;Fe ./4 -.- S.‘<br>6040 ¢Fa¢?me47soMosenooheSa--o “7“7“ ‘‘‘s.SS —=a-. Typical process Prozess limits<br>20 Sa Heating rate < 3 °K/s “es Temperature on board<br>0<br>0 20 40 60 80 100 120 140 160 180 200 220 240<br>time [s]<br>Double Wave:<br>260 255 °C — 260 °C<br>Total contact time max. 10 sec. Q 250 °C<br>240<br>220<br>200<br>180<br>\<br>160 eee sue\\<br>140120100 Preheating a?’.a”oa a..ue °°&.SS£ 7*.“eS?ny“ocd;7 appr. 150°C [RO\‘\‘\‘‘ NS>NOS.°WSesyO~~>-°°~~ ~~~<br>8060 a?-o7747 *Aefre/&°oo&&4aea7”’ \‘‘‘‘\ Cooling rate < 6 °K/s ‘‘ >cS““Sse°“asD>,-_;-:<br>o* A. “ Typical process<br>40 Prie"7-- neeiteer<r — Process limits<br>20 Heating rate < 3 °K/s Temperature on board<br>0<br>0 20 40 60 80 100 120 140 160 180 200 220 240<br>time [s]<br>Temperature [°C]<br>Temperature [°C]<br>**----- End of picture text -----**<br>
##
Wired connection elements should be processed in accordance with the DIN EN 61760-1 standard. We have included two recommendations for practical wave soldering profiles, with which Weidmüller PCB terminals and connectors are qualified.
- PCB thickness
- Proportion of Cu in the layers
- Single/double-sided assembly
- Product range
- Heating and cooling rates
soldering temperature of 260°C. In practice, the maximum soldering temperature is quite often well below the above maximum profile.
We reserve the right to make technical changes.
Updated at June 5, 2026
Weidmüller is a leading international provider of advanced solutions for electrical connectivity, power transmission, and the conditioning of signals and data in industrial environments. Recognized globally for engineering excellence, the company develops innovative components designed to optimize automation, ensure reliable power distribution, and streamline complex control panel assemblies. Our extensive portfolio of Weidmüller components is strongly centered around their industry-leading connectivity solutions. We carry a vast selection of terminal blocks to suit any application, including pluggable terminal blocks, headers and sockets, wire-to-board solutions, and rugged DIN rail terminal blocks. To support complete and organized installations, we also provide a comprehensive range of standard and fused terminal blocks, power distribution blocks, interface modules, and essential accessories like terminal block markers. Beyond core connectivity, our offering includes critical Weidmüller components for system protection and control. We supply a robust selection of circuit breakers, featuring magnetic hydraulic, thermal, and electronic variants to safeguard sensitive equipment. Additionally, our inventory encompasses dependable power relays, solid-state relays, and AC/DC converters, equipping engineers with the high-quality parts needed to build secure, efficient, and fully integrated industrial automation systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →