Image not available
Illustrative purposes only
20.21.8.024.4000
General Purpose Relay, 20 Series, Power, SPST-NO, 24 VAC, 16 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: FINDER
- Product type: Power Relays
- Contact Configuration:SPST-NO; Coil Voltage:24VAC; Contact Current:16A; Product Range:20 Series; Relay Mounting:DIN Rail; Coil Type:-; Contact Voltage VAC:250VAC; Relay Terminals:Screw; Conta
- SVHC: No SVHC (04-Feb-2026)
- Coil Type: -
- Coil Voltage: 24VAC
- Product Range: 20 Series
- Relay Mounting: DIN Rail
- Coil Resistance: 27ohm
- Contact Current: 16A
- Relay Terminals: Screw
- Contact Material: Silver Tin Oxide
- Contact Voltage VAC: 250VAC
- Contact Voltage VDC: -
- Contact Configuration: SPST-NO
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 20.52 € |
| Current stock | 10+ |
| Lead time | 30 days |
**20 SERIES** ## **1 or 2 Pole 16 A Step relays for direct 35 mm rail (EN 60715) mounting** **==> picture [25 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 20.21<br>**----- End of picture text -----**<br> ## **20.22, 24, 26, 27, 28** **==> picture [26 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 20.23<br>**----- End of picture text -----**<br> - 17.4 mm wide - Test button with mechanical indicators - Choice of 7 switching sequences - AC coils and DC coils - Identification label - Possible to connect illuminated push buttons with the additional part 026.00 - 35 mm rail (EN 60715) mount - Cadmium free contact material 20.21/22/24/26/27/28/23 Screw terminal - Single phase switch 1 NO (SPST-NO) - 35 mm rail (EN 60715) mount - Double phase switch - 35 mm rail (EN 60715) mount - Double phase switch 1NO+1NC (SPST-NO+SPST-NC) - 35 mm rail (EN 60715) mount ## _For UL ratings see:_ _“General technical information” page_ V For outline drawing see page 3 ## **Contact specification** ||**Contact specification**||||||| |---|---|---|---|---|---|---|---| ||Contact configuration|1 NO (SPST-NO)|||2 NO (DPST-N~~O~~)||1NO+1NC (SPST-~~N~~O+SPST-NC)| ||Rated current/Maximum peak current<br>A|16/30||||16/30|16/30| ||Rated voltage/<br>Maximum switchingvoltage<br>V AC|250/400||||250/400|250/400| ||Rated load AC1<br>VA|4000||||4000|4000| ||Rated load AC15 (230 V AC)<br>VA|750||||750|750| ||Nominal lamp rating:<br>230 V incandescent/halogen W|2000||||2000|2000| ||fluorescent tubes with<br>electronic ballast W|1000||||1000|1000| ||fluorescent tubes with<br>electromechanical ballast W|750||||750|750| ||CFL W|400||||400|400| ||230 V LED W|400||||400|400| ||LV halogen or LED with<br>electronic ballast W|400||||400|400| ||LV halogen or LED with<br>electromechanical ballast W|800||||800|800| ||Minimum switching load<br>mW (V/mA)|1000 (10/10)|||1000 (10/10)||1000 (10/10)| ||Standard contact material<br>**Coil specification**|AgSnO2||||AgSnO2|AgSnO2| ||Nominal voltage (UN)<br>V AC (50/60 Hz)||8 - 12 - 24 - 48 - 110 - 120 - 230 - 240||||| ||V DC|12 - 24 - 48 - 110|||12 - 24 - 48 - 110|12 - 24 - 48 - 110|12 - 24 - 48 - 110| ||Rated power AC/DC<br>VA (50 Hz)/W|6.5/5||||6.5/5|6.5/5| ||Operating range<br>AC||(0.85…1.1)UN(50 Hz)/(0.9…1.1)UN(60 Hz)||||(60 Hz)| ||DC<br>**Technical data**|(0.9…1.1)UN|||(0.9…1.1)UN||(0.9…1.1)UN| ||Mechanical life AC/DC<br>cycles|300 · 103|||300 · 103||300 · 103| ||Electrical life at rated load in AC1<br>cycles|100 · 103|||100 · 103||100 · 103| ||Minimum/Maximum impulse duration|0.1 s/1 h (according to EN 60669)|0.1 s/1 h (according to EN 60669)|0.1 s/1 h (according to EN 60669)|||0.1 s/1 h (according to EN 60669)| |III-2016, www.findernet.com|Insulation between coil<br>and contacts(1.2/50µs)<br>kV<br>Ambient temperature range<br>°C<br>Protection category<br>**Approvals**(according to type)|4<br>–40…+40<br>IP 20<br>~~C€~~|~~HAL~~|~~S©~~|4<br>–40…+40<br>IP 20<br>~~©EB®RNA~~||4<br>–40…+40<br>IP 20<br>~~RNAWis~~| **K** **1** **20 SERIES** ## **Ordering information** Example: 20 series relay, 35 mm rail (EN 60715) mount, double phase switch, 2 NO 16 A contacts, coil rated at 12 V DC, AgSnO2 contacts. **2 0 . 2 2 . 9 . 0 1 2 . 4 0 0 0** ## **Series** ## **Contact material** 0 = AgNi ## **Type** 4 = AgSnO2 2 = 35 mm rail (EN 60715) mount ## **No. of poles** **Coil voltage** See coil specifications 1 = Single phase switch 1 NO (SPST-NO) - 2 = Double phase switch 2 NO (DPST-NO) 3 = Double phase switch 1 NC+ 1 NO (SPST-NO+SPST-NC) 4 = 4 sequence double phase switch 2 NO (DPST-NO) ## **Coil version** 8 = AC (50/60 Hz) 9 = DC 6 = 3 sequence double phase switch 2 NO (DPST-NO) 7 = 3 sequence double phase switch 2 NO (DPST-NO) 8 = 4 sequence double phase switch 2 NO (DPST-NO) ## **Technical data** ## **Insulation** |Dielectric strength<br>between supplyand contacts<br>V AC|3500| |---|---| |between open contacts<br>V AC|2000| |between adjacent contacts<br>V AC <br>**Other data**|2000| |Power lost to the environment|| with rated current and coil deenergised Wgised Wised W 1.3 (20.21, 20.23, 20.28)(20.21, 20.23, 20.28)20.21, 20.23, 20.28), 20.23, 20.28) 20.23, 20.28), 20.28) 20.28)) with rated current and coil deenergised Wgised Wised W 1.3 (20.21, 20.23, 20.28)(20.21, 20.23, 20.28)20.21, 20.23, 20.28), 20.23, 20.28) 20.23, 20.28), 20.28) 20.28)) 2.6 (20.22, 20.24, 20.26, 20.27) ©[Screw torque ] Nm ~~pO~~ 0.8 0.8 **Coil terminals Contact terminals** Max. wire size solid cable stranded cable solid cable stranded cable ~~————~~ mm[2] 1 x 4 / 2 x 2.5 1 x 2.5 / 2 x 2.5 1 x 6 / 2 x 4 1 x 4 / 2 x 2.5 ~~es~~ AWG ~~ee~~ 1 x 12 / 2 x 14 1 x 14 / 2 x 14 1 x 10 / 2 x 12 1 x 12 / 2 x 14 If the coil is operated for a prolonged period of time, adequate ventilation of the relays must be provided - suggested gap of 9 mm between adjacent relays. ## **Coil specifications** ## **DC version data** ||Nominal<br>voltage<br>Coil<br>code<br>Operating range<br>ResistanceConsumption<br>Iat UN<br>UN<br>Umin<br>Umax<br>R<br>V<br>V<br>V<br>Ω<br>mA| |---|---| ||12<br>**9**.012<br>10.8<br>13.2<br>27<br>440<br>24<br>**9**.024<br>21.6<br>26.4<br>105<br>230| |**K**|48<br>**9**.048<br>43.2<br>52.8<br>440<br>110<br>110<br>**9**.110<br>99<br>121<br>2330<br>47| ||**AC version data**<br>Nominal<br>voltage<br>Coil<br>code<br>Operating range<br>ResistanceConsumption<br>Iat UN<br>UN<br>Umin<br>Umax<br>R<br>(50 Hz)<br>V<br>V<br>V<br>Ω<br>mA<br>8<br>**8**.008<br>6.8<br>8.8<br>4<br>800<br>~~oo~~| ||12<br>**8**.012<br>10.2<br>13.2<br>7.5<br>550| ||24<br>**8**.024<br>20.4<br>26.4<br>27<br>275<br>48<br>**8**.048<br>40.8<br>52.8<br>106<br>150<br>110<br>**8**.110<br>93.5<br>121<br>590<br>64<br>120<br>**8**.120<br>102<br>132<br>680<br>54<br>230<br>**8**.230<br>192<br>253<br>2500<br>28<br>240<br>**8**.240<br>204<br>264<br>2700<br>27.5<br>~~EE~~<br>~~ee~~<br>~~ee~~<br>~~ee ee es~~<br>~~a~~<br>~~eees~~| **Number Sequence Type of steps** 1 2 3 4 ~~eee~~ 20.21 2 ~~Seti~~ 20.22 2 ~~Nth~~ 20.23 2 ~~|~~ RN | | 20.24 4 20.26 3 ~~Hae~~ 20.27 3 ~~RRA]~~ 20.28 4 **2** **20 SERIES** **K** ## **Wiring diagrams** **==> picture [176 x 200] intentionally omitted <==** **----- Start of picture text -----**<br> L<br>N<br>Example: 230 V AC supply voltage.<br>**----- End of picture text -----**<br> **==> picture [185 x 200] intentionally omitted <==** **----- Start of picture text -----**<br> L<br>N<br>Example: 24 V AC supply voltage.<br>**----- End of picture text -----**<br> ## **Outline drawings** 20.21 Screw terminal **==> picture [39 x 40] intentionally omitted <==** **==> picture [112 x 112] intentionally omitted <==** 20.22/24/26/27/28 Screw terminal **==> picture [39 x 40] intentionally omitted <==** **==> picture [113 x 113] intentionally omitted <==** 20.23 Screw terminal **==> picture [39 x 39] intentionally omitted <==** **==> picture [114 x 113] intentionally omitted <==** **3** **20 SERIES** ## **Accessories** ## **Module for use with illuminated push-buttons** ## **Type 026.00** Sealed construction, 7.5 cm insulated flexible wire termination. ## **Example of wiring diagram of type 026.00** This module is necessary when using between 1 and a maximum of 15 illuminated push buttons in the coil circuit (Each 1.5 mA max, 230 V AC). It must be connected in parallel to the coil of the relay. **Adaptor for panel mounting,** 17.5 mm wide 020.01 **==> picture [29 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> 020.01<br>**----- End of picture text -----**<br> ~~=~~ **Sheet of marker tags,** plastic, 24 tags, 9 x 17 mm 020.24 **020.24** 022.09 **020.24 Separator for rail mounting,** plastic, 9 mm wide 022.09 ‘ **022.09** a ~~ctly~~ **K** **4**
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →