1SVR405659R1000
Relay Accessory, Holder, ABB CR-M Series Relay Sockets, CR-M Series
- Manufacturer: ABB
- Product type: Other Relay Accessories
- Accessory Type:Holder; For Use With:ABB CR-M Series Relay Sockets; Product Range:CR-M Series; SVHC:No SVHC (15-Jan-2018)
- SVHC: To Be Advised
- For Use With: ABB CR-M Series Relay Sockets
- Product Range: CR-M Series
- Accessory Type: Holder
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 0.712 € |
| Current stock | 10+ |
| Lead time | 9 days |
Data sheet ## Pluggable interface relays CR-M Miniature relays Pluggable interface relays are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC (programmable logic controller), PC or field bus systems and the sensor / actuator level. They don’t use additional internal protective circuits and thus are overload-proof against short-time variations like current or voltage peaks. ## Characteristics - Standard miniature relays with mechanical status indication - 13 different rated control supply voltages: DC versions: 12 V, 24 V, 48 V, 60 V, 110 V, 125 V, 220 V AC versions: 24 V, 48 V, 60 V, 110 V, 120 V, 230 V - Output: 2 c/o (SPDT) contacts (12 A), 3 c/o (SPDT) contacts (10 A) or 4 c/o (SPDT) contacts (6 A) - Available with or without LED - 4 c/o (SPDT) contact version optionally equipped with gold contacts, LED and free wheeling diode - Integrated test button for manual actuation and locking of output contacts (DC coil = blue, AC coil = orange) that can be removed if necessary ## Approvals H ANSI/UL 508, CAN/CSA C22.2 No.14 F CAN/CSA C22.2 No.14 J VDE (except 125 V DC devices) R EAC P Lloyds Register (only devices with 4 c/o (SPDT) contacts) E CCC L RMRS (except 60 V and 125 V devices) ## Marks a CE - Cadmium-free contact material - Suited for logical and standard sockets - Width on socket: 27 mm (1.063 in) - Pluggable function modules: reverse polarity protection/ free wheeling diode, LED indication, RC elements, overvoltage protection Order data Packing unit = 10 pieces Interface relays without LED, 2 c/o (SPDT) contacts: 250 V, 12 A **==> picture [511 x 562] intentionally omitted <==** **----- Start of picture text -----**<br> Type Rated control supply voltage Us Order code<br>CR-M012DC2 12 V DC 1SVR 405 611 R4000<br>CR-M024DC2 24 V DC 1SVR 405 611 R1000<br>CR-M048DC2 48 V DC 1SVR 405 611 R6000<br>CR-M060DC2 60 V DC 1SVR 405 611 R4200<br>CR-M110DC2 110 V DC 1SVR 405 611 R8000<br>CR-M125DC2 125 V DC 1SVR 405 611 R8200<br>CR-M220DC2 220 V DC 1SVR 405 611 R9000<br>CR-M024AC2 24 V AC 1SVR 405 611 R0000<br>CR-M048AC2 48 V AC 1SVR 405 611 R5000<br>CR-M110AC2 110 V AC 1SVR 405 611 R7000<br>CR-M120AC2 120 V AC 1SVR 405 611 R2000<br>CR-M230AC2 230 V AC 1SVR 405 611 R3000<br>Interface relays without LED, 3 c/o (SPDT) contacts: 250 V, 10 A<br>CR-M012DC3 12 V DC 1SVR 405 612 R4000<br>CR-M024DC3 24 V DC 1SVR 405 612 R1000<br>CR-M048DC3 48 V DC 1SVR 405 612 R6000<br>CR-M060DC3 60 V DC 1SVR 405 612 R4200<br>CR-M110DC3 110 V DC 1SVR 405 612 R8000<br>CR-M125DC3 125 V DC 1SVR 405 612 R8200<br>CR-M220DC3 220 V DC 1SVR 405 612 R9000<br>CR-M024AC3 24 V AC 1SVR 405 612 R0000<br>CR-M048AC3 48 V AC 1SVR 405 612 R5000<br>CR-M060AC3 60 V AC 1SVR 405 612 R5200<br>CR-M110AC3 110 V AC 1SVR 405 612 R7000<br>CR-M120AC3 120 V AC 1SVR 405 612 R2000<br>CR-M230AC3 230 V AC 1SVR 405 612 R3000<br>Interface relays without LED, 4 c/o (SPDT) contacts: 250 V, 6 A<br>CR-M012DC4 12 V DC 1SVR 405 613 R4000<br>CR-M024DC4 24 V DC 1SVR 405 613 R1000<br>CR-M048DC4 48 V DC 1SVR 405 613 R6000<br>CR-M060DC4 60 V DC 1SVR 405 613 R4200<br>CR-M110DC4 110 V DC 1SVR 405 613 R8000<br>CR-M125DC4 125 V DC 1SVR 405 613 R8200<br>CR-M220DC4 220 V DC 1SVR 405 613 R9000<br>CR-M024AC4 24 V AC 1SVR 405 613 R0000<br>CR-M048AC4 48 V AC 1SVR 405 613 R5000<br>CR-M110AC4 110 V AC 1SVR 405 613 R7000<br>CR-M120AC4 120 V AC 1SVR 405 613 R2000<br>CR-M230AC4 230 V AC 1SVR 405 613 R3000<br>**----- End of picture text -----**<br> 2 - Pluggable interface relays CR-M | Data sheet Interface relays with LED, 2 c/o (SPDT) contacts: 250 V, 12 A **==> picture [511 x 175] intentionally omitted <==** **----- Start of picture text -----**<br> Type Rated control supply voltage Us Order code<br>CR-M012DC2L 12 V DC 1SVR 405 611 R4100<br>CR-M024DC2L 24 V DC 1SVR 405 611 R1100<br>CR-M048DC2L 48 V DC 1SVR 405 611 R6100<br>CR-M060DC2L 60 V DC 1SVR 405 611 R4300<br>CR-M110DC2L 110 V DC 1SVR 405 611 R8100<br>CR-M125DC2L 125 V DC 1SVR 405 611 R8300<br>CR-M220DC2L 220 V DC 1SVR 405 611 R9100<br>CR-M024AC2L 24 V AC 1SVR 405 611 R0100<br>CR-M048AC2L 48 V AC 1SVR 405 611 R5100<br>CR-M110AC2L 110 V AC 1SVR 405 611 R7100<br>CR-M120AC2L 120 V AC 1SVR 405 611 R2100<br>CR-M230AC2L 230 V AC 1SVR 405 611 R3100<br>**----- End of picture text -----**<br> Interface relays with LED, 3 c/o (SPDT) contacts: 250 V, 10 A **==> picture [511 x 348] intentionally omitted <==** **----- Start of picture text -----**<br> CR-M012DC3L 12 V DC 1SVR 405 612 R4100<br>CR-M024DC3L 24 V DC 1SVR 405 612 R1100<br>CR-M048DC3L 48 V DC 1SVR 405 612 R6100<br>CR-M060DC3L 60 V DC 1SVR 405 612 R4300<br>CR-M110DC3L 110 V DC 1SVR 405 612 R8100<br>CR-M125DC3L 125 V DC 1SVR 405 612 R8300<br>CR-M220DC3L 220 V DC 1SVR 405 612 R9100<br>CR-M024AC3L 24 V AC 1SVR 405 612 R0100<br>CR-M048AC3L 48 V AC 1SVR 405 612 R5100<br>CR-M110AC3L 110 V AC 1SVR 405 612 R7100<br>CR-M120AC3L 120 V AC 1SVR 405 612 R2100<br>CR-M230AC3L 230 V AC 1SVR 405 612 R3100<br>Interface relays with LED, 4 c/o (SPDT) contacts: 250 V, 6 A<br>CR-M012DC4L 12 V DC 1SVR 405 613 R4100<br>CR-M024DC4L 24 V DC 1SVR 405 613 R1100<br>CR-M048DC4L 48 V DC 1SVR 405 613 R6100<br>CR-M060DC4L 60 V DC 1SVR 405 613 R4300<br>CR-M110DC4L 110 V DC 1SVR 405 613 R8100<br>CR-M125DC4L 125 V DC 1SVR 405 613 R8300<br>CR-M220DC4L 220 V DC 1SVR 405 613 R9100<br>CR-M024AC4L 24 V AC 1SVR 405 613 R0100<br>CR-M048AC4L 48 V AC 1SVR 405 613 R5100<br>CR-M110AC4L 110 V AC 1SVR 405 613 R7100<br>CR-M120AC4L 120 V AC 1SVR 405 613 R2100<br>CR-M230AC4L 230 V AC 1SVR 405 613 R3100<br>**----- End of picture text -----**<br> Interface relays with LED and free wheeling diode, 4 c/o (SPDT) contacts: 250 V, 6 A **==> picture [511 x 95] intentionally omitted <==** **----- Start of picture text -----**<br> CR-M024DC4LD 24 V DC 1SVR 405 614 R1100<br>Interface relays with gold contacts, 4 c/o (SPDT) contacts: 250 V, 6 A<br>CR-M024DC4G 24 V DC 1SVR 405 618 R1000<br>CR-M024AC4G 24 V AC 1SVR 405 618 R0000<br>CR-M110AC4G 110 V AC 1SVR 405 618 R7000<br>CR-M230AC4G 230 V AC 1SVR 405 618 R3000<br>**----- End of picture text -----**<br> Data sheet | Pluggable interface relays CR-M - 3 Interface relays with LED and gold contacts, 4 c/o (SPDT) contacts: 250 V, 6 A **==> picture [511 x 229] intentionally omitted <==** **----- Start of picture text -----**<br> Type Rated control supply voltage Us Order code<br>CR-M012DC4LG 12 V DC 1SVR 405 618 R4100<br>CR-M024DC4LG 24 V DC 1SVR 405 618 R1100<br>CR-M048DC4LG 48 V DC 1SVR 405 618 R6100<br>CR-M060DC4LG 60 V DC 1SVR 405 618 R4300<br>CR-M110DC4LG 110 V DC 1SVR 405 618 R8100<br>CR-M125DC4LG 125 V DC 1SVR 405 618 R8300<br>CR-M220DC4LG 220 V DC 1SVR 405 618 R9100<br>CR-M024AC4LG 24 V AC 1SVR 405 618 R0100<br>CR-M048AC4LG 48 V AC 1SVR 405 618 R5100<br>CR-M110AC4LG 110 V AC 1SVR 405 618 R7100<br>CR-M120AC4LG 120 V AC 1SVR 405 618 R2100<br>CR-M230AC4LG 230 V AC 1SVR 405 618 R3100<br>Interface relays with gold contacts, LED and free wheeling diode, 4 c/o (SPDT) contacts: 250 V, 6 A<br>CR-M012DC4LDG 12 V DC 1SVR 405 618 R4400<br>CR-M024DC4LDG 24 V DC 1SVR 405 618 R1400<br>**----- End of picture text -----**<br> ## Accessories Packing unit = 10 pieces ## Function modules Type Rated control supply voltage Us Version Order code ## Diode - Reverse polarity protection **==> picture [511 x 316] intentionally omitted <==** **----- Start of picture text -----**<br> CR-P/M 22 6-220 V DC A1+, A2- 1SVR 405 651 R0000<br>Diode and LED - Reverse polarity protection<br>CR-P/M 42 6-24 V DC red, A1+, A2- 1SVR 405 652 R0000<br>CR-P/M 42V 6-24 V DC green, A1+, A2- 1SVR 405 652 R1000<br>CR-P/M 42B 24-60 V DC red, A1+, A2- 1SVR 405 652 R4000<br>CR-P/M 42BV 24-60 V DC green, A1+, A2- 1SVR 405 652 R4100<br>CR-P/M 42C 110 V DC red, A1+, A2- 1SVR 405 652 R9000<br>CR-P/M 42CV 110 V DC green, A1+, A2- 1SVR 405 652 R9100<br>RC element - Arc elimination<br>CR-P/M 52B 6-24 V AC/DC 1SVR 405 653 R0000<br>CR-P/M 52D 24-60 V AC/DC 1SVR 405 653 R4000<br>CR-P/M 52C 110-230 V AC/DC 1SVR 405 653 R1000<br>Diode and LED<br>CR-P/M 62 6-24 V AC/DC red, for DC: A1+, A2- 1SVR 405 654 R0000<br>CR-P/M 62V 6-24 V AC/DC green, for DC: A1+, A2- 1SVR 405 654 R1000<br>CR-P/M 62E 24-60 V AC/DC red, for DC: A1+, A2- 1SVR 405 654 R4000<br>CR-P/M 62EV 24-60 V AC/DC green, for DC: A1+, A2- 1SVR 405 654 R4100<br>CR-P/M 92 110-230 V AC / 110 V DC red, for DC: A1+, A2- 1SVR 405 654 R0100<br>CR-P/M 92V 110-230 V AC / 110 V DC green, for DC: A1+, A2- 1SVR 405 654 R1100<br>**----- End of picture text -----**<br> 4 - Pluggable interface relays CR-M | Data sheet ## Varistor and LED - Overvoltage protection **==> picture [511 x 82] intentionally omitted <==** **----- Start of picture text -----**<br> CR-P/M 62C 6-24 V AC/DC red, for DC: A1+, A2- 1SVR 405 655 R0000<br>CR-P/M 62CV 6-24 V AC/DC green, for DC: A1+, A2- 1SVR 405 655 R1000<br>CR-P/M 62D 24-60 V AC/DC red, for DC: A1+, A2- 1SVR 405 655 R4000<br>CR-P/M 62DV 24-60 V AC/DC green, for DC: A1+, A2- 1SVR 405 655 R4100<br>CR-P/M 92C 110-230 V AC / 110 V DC red, for DC: A1+, A2- 1SVR 405 655 R0100<br>CR-P/M 92CV 110-230 V AC / 110 V DC green, for DC: A1+, A2- 1SVR 405 655 R1100<br>**----- End of picture text -----**<br> ## Varistor - Overvoltage protection **==> picture [511 x 41] intentionally omitted <==** **----- Start of picture text -----**<br> CR-P/M 72 24 V AC 1SVR 405 656 R0000<br>CR-P/M 72A 115 V AC 1SVR 405 656 R1000<br>CR-P/M 82 230 V AC 1SVR 405 656 R2000<br>**----- End of picture text -----**<br> ## Plug to replace the test button (Packing unit = 100 pieces) **==> picture [511 x 341] intentionally omitted <==** **----- Start of picture text -----**<br> CR-MP 1SVR 405 658 R2000<br>Sockets<br>Type Version Connection Order code<br>Logical sockets<br>CR-M2LS for 2 c/o (SPDT) contacts screw 1SVR 405 651 R1100<br>CR-M3LS for 3 c/o (SPDT) contacts screw 1SVR 405 651 R2100<br>CR-M4LS for 2 or 4 c/o (SPDT) contacts screw 1SVR 405 651 R3100<br>CR-M2LC for 2 c/o (SPDT) contacts spring 1SVR 405 651 R1200<br>CR-M4LC for 2 or 4 c/o (SPDT) contacts spring 1SVR 405 651 R3200<br>Standard sockets<br>CR-M2SS for 2 c/o (SPDT) contacts screw 1SVR 405 651 R1000<br>CR-M3SS for 3 c/o (SPDT) contacts screw 1SVR 405 651 R2000<br>CR-M4SS for 2 or 4 c/o (SPDT) contacts screw 1SVR 405 651 R3000<br>CR-M2SF for 2 c/o (SPDT) contacts fork type screw 1SVR 405 651 R1300<br>CR-M4SF for 2 or 4 c/o (SPDT) contacts fork type screw 1SVR 405 651 R3300<br>Accessories for CR-M sockets<br>CR-MH Plastic holder 1SVR 405 659 R1000<br>CR-MH1 Metall holder 1SVR 405 659 R1100<br>CR-MJ Jumper bar for sockets with screw clamps 1SVR 405 658 R6000<br>CR-MM Marker 1SVR 405 658 R1000<br>**----- End of picture text -----**<br> Data sheet | Pluggable interface relays CR-M - 5 Functions ## Operating controls **==> picture [241 x 203] intentionally omitted <==** **----- Start of picture text -----**<br> = ~ 1<br>2<br>>» 4 oa<br>| eoe™ta Vi<br>3<br>4<br>2CDC 295 003 F0011<br>**----- End of picture text -----**<br> **==> picture [114 x 77] intentionally omitted <==** **----- Start of picture text -----**<br> _ 1 Socket<br>2 Pluggable function module<br>3 Interface relay<br>4 Holder<br>||<br>**----- End of picture text -----**<br> ## Application Interface relays are electromechanic and electronic input and output modules for electrical isolation, levelling, noise suppression or signal amplifi cation between control unit and process. ## Operating mode When control supply voltage is applied, the output contacts get closed. When control supply voltage is switched off, the contacts fall back into their starting position. Manual operation and locking of the output relays is possible via the integrated test button. ## Note: During operation of the relay the test button is warming up. To manually press the test button, first switch off the supply voltage of the relay and wait for a while until the button cools down (or press without delay, using protective gloves or insulated tools). Press the button smoothly and quickly. As long as the button is pressed the n/o contacts are closed. Releasing the button opens the n/o contacts. A 90 degree rotation of the test button closes the n/o contacts permanently. Reverse rotation of the test button re-opens the n/o contacts. 6 - Pluggable interface relays CR-M | Data sheet Electrical connection ## CR-M with 2 c/o (SPDT) contacts **==> picture [270 x 575] intentionally omitted <==** **----- Start of picture text -----**<br> A1-A2 Control supply voltage<br>11-12/14, Relay outputs<br>41-42/44<br>Connection diagram<br>CR-M with 3 c/o (SPDT) contacts<br>A1-A2 Control supply voltage<br>11-12/14, Relay outputs<br>21-22/24,<br>31-32/34<br>Connection diagram<br>CR-M with 4 c/o (SPDT) contacts<br>A1-A2 Control supply voltage<br>11-12/14, Relay outputs<br>21-22/24,<br>31-32/34,<br>41-42/44<br>Connection diagram<br>2CDC 292 011 F0004<br>2CDC 292 016 F0004<br>2CDC 292 020 F0004<br>**----- End of picture text -----**<br> Data sheet | Pluggable interface relays CR-M - 7 ## Technical data Input circuit - Coil data A1-A2 **==> picture [510 x 210] intentionally omitted <==** **----- Start of picture text -----**<br> Rated con- Rated Make Maxium Break Rated power Coil Tolerance of<br>trol supply frequency voltage voltage voltage resistance coil<br>voltage Us (at 20 °C) (at 55 °C) (at 20 °C) resistance<br>DC coils 12 V DC - 9.6 V DC 13.2 V DC ≥ 0.1 Us 0.9 W 160 Ω ± 10 %<br>24 V DC - 19.2 V DC 26.4 V DC ≥ 0.1 Us 0.9 W 640 Ω ± 10 %<br>48 V DC - 38.4 V DC 52.8 V DC ≥ 0.1 Us 0.9 W 2600 Ω ± 10 %<br>60 V DC - 48.0 V DC 66.0 V DC ≥ 0.1 Us 0.9 W 4000 Ω ± 10 %<br>110 V DC - 88.0 V DC 121.0 V DC ≥ 0.1 Us 0.9 W 13600 Ω ± 10 %<br>125 V DC - 100.0 V DC 137.5 V DC ≥ 0.1 Us 0.9 W 16000 Ω ± 10 %<br>220 V DC - 176.0 V DC 242.0 V DC ≥ 0.1 Us 0.9 W 54000 Ω ± 10 %<br>AC coils 24 V AC 50/60 Hz 19.2 V AC 26.4 V AC ≥ 0.2 Us 1.6 VA 158 Ω ± 10 %<br>48 V AC 50/60 Hz 38.4 V AC 52.8 V AC ≥ 0.2 Us 1.6 VA 640 Ω ± 10 %<br>60 V AC 50/60 Hz 48.0 V AC 66.0 V AC ≥ 0.2 Us 1.6 VA 930 Ω ± 10 %<br>110 V AC 50/60 Hz 88.0 V AC 121.0 V AC ≥ 0.2 Us 1.6 VA 3450 Ω ± 10 %<br>120 V AC 50/60 Hz 96.0 V AC 132.0 V AC ≥ 0.2 Us 1.6 VA 3770 Ω ± 10 %<br>230 V AC 50/60 Hz 184.0 V AC 253.0 V AC ≥ 0.2 Us 1.6 VA 16100 Ω ± 10 %<br>**----- End of picture text -----**<br> ## Output circuits **==> picture [503 x 474] intentionally omitted <==** **----- Start of picture text -----**<br> Type CR-M...2 CR-M...3 CR-M...4<br>Output circuits 11-12/14, 11-12/14, 11-12/14,<br>21-22/24 21-22/24, 21-22/24,<br>31-32/34 31-32/34,<br>41-42/44<br>Kind of output Relay, 2 c/o Relay, 3 c/o Relay, 4 c/o<br>(SPDT) contacts (SPDT) contacts (SPDT) contacts<br>Contact material AgNi AgNi AgNi<br>AgNi/Au 5 μm<br>Rated operational voltage Ue (IEC/EN 60947-1) 250 V<br>Minimum switching voltage 10 V (AgNi), 5 V (AgNi/Au)<br>Maximum switching voltage 250 V DC / 250 V AC<br>Minimum switching current 5 mA (AgNi), 2 mA (AgNi/Au)<br>Rated free air thermal current Ith 12 A 10 A 6 A<br>Rated operational current (IEC/EN 60947-5-1) AC-12 (resistive) 230 V 12 A 10 A 6 A<br>AC-15 (inductive) 230 V 1.5 A 1.5 A 1 A<br>AC-15 (inductive) 120 V 3 A 3 A 1.5 A<br>DC-12 (resistive) 24 V 12 A 10 A 6 A<br>DC-13 (inductive) 24 V 2.5 A 2.5 A 2 A<br>DC-13 (inductive) 120 V 0.22 A 0.22 A 0.22 A<br>DC-13 (inductive) 250 V 0.1 A 0.1 A 0.1 A<br>AC rating * Utilization category (pilot duty) B300<br>(UL 508; NEMA ICS-5) (Contact rating code designation)<br>Max. rated operational voltage 300 V AC<br>Max. continuous thermal current 5 A 2.5 A<br>at utilization category<br>Max. making / breaking apparent 3600 / 360 VA 1800 / 180 VA<br>power at utilization category<br>Utilization category (resistive) 10 A, 250 V AC 6 A, 250 V AC 5 A, 250 V AC<br>(CSA22.2 No.14....) 12 A, 150 V AC 10 A, 150 V AC 10 A, 150 V AC<br>DC rating * Utilization category (pilot duty) R300<br>(UL 508; NEMA ICS-5) (Contact rating code designation)<br>Max. rated operational voltage 300 V DC<br>Max. continuous thermal current 1 A<br>at utilization category<br>Max. making / breaking apparent 28 VA<br>power at utilization category<br>**----- End of picture text -----**<br> 8 - Pluggable interface relays CR-M | Data sheet **==> picture [503 x 176] intentionally omitted <==** **----- Start of picture text -----**<br> Type CR-M...2 CR-M...3 CR-M...4<br>Maximum making (inrush) current 24 A 20 A 12 A<br>Minimum switching power 0.3 W (AgNi), 0.1 W (AgNi/Au)<br>Maximum switching (breaking) power AC1 (resistive) 3000 VA 2500 VA 1500 VA<br>Contact resistance ≤ 100 mΩ<br>Maximum operating frequency rated load AC1 1200 switching cycles/h<br>without load 18000 switching cycles/h<br>Mechanical lifetime > 2 x 10 [7] switching cycles<br>Electrical lifetime electrical AC1 (resistive) > 10 [5] switching cycles<br>(12 A, 250 V) (10 A, 250 V) (6 A, 250 V)<br>cos φ see Reduction factor F<br>Response time typ. 13 ms (DC), typ. 10 ms (AC)<br>Release time typ. 3 ms (DC), typ. 8 ms (AC)<br>**----- End of picture text -----**<br> *) Those ratings are based on different type tests but they are not covered by the cULus or CSA approvals ## Isolation data **==> picture [511 x 418] intentionally omitted <==** **----- Start of picture text -----**<br> Type CR-M...2 CR-M...3 CR-M...4<br>Rated insulation voltage 250 V AC<br>Insulation class C250 / B250<br>Rated impulse withstand between coil and contacts 2.5 kV<br>voltage Uimp between open contacts 1.5 kV<br>between c/o (SPDT) contacts 2.5 kV ≥ 2 kV<br>Clearance between coil and contacts ≥ 2.5 mm ≥ 1.6 mm<br>Creepage distance between coil and contacts ≥ 4 mm ≥ 3.2 mm<br>Overvoltage category III II<br>Pollution degree 3 2<br>General data<br>Type CR-M...2 CR-M...3 CR-M...4<br>Dimensions (W x H x D) when mounted 21.2 x 27.5 x 35.6 mm (0.83 x 1.08 x 1.4 in)<br>Weight 35 g (0.077 lb)<br>Mounting on socket (see accessories)<br>Mounting position any<br>Degree of protection IP 40<br>Electrical data<br>Type CR-M...2 CR-M...3 CR-M...4<br>Connection by socket<br>Environmental data<br>Type CR-M...2 CR-M...3 CR-M...4<br>Ambient temperature range operation DC: -40...+70 °; AC: -40...+55 °C<br>storage -40...+85 °C<br>Vibration resistance (10-150 Hz) n/o contact 5 g<br>n/c contact 5 g<br>Shock resistance n/o contact 10 g<br>n/c contact 5 g<br>**----- End of picture text -----**<br> ## Standards / Directives |Standards / Directives|||| |---|---|---|---| |Type|CR-M...2|CR-M...3|CR-M...4| |Standards|IEC/EN 61810-1||| |Low Voltage Directive|2014/35/EU||| |RoHS Directive|2011/65/EU||| Data sheet | Pluggable interface relays CR-M - 9 Technical diagrams Load limit curves - Maximum switching power at resistive DC load **==> picture [336 x 563] intentionally omitted <==** **----- Start of picture text -----**<br> 1 = resistive load, T = 0 ms<br>2 = inductive load, T = 40 ms<br>DC voltage [V] DC voltage [V]<br>Versions with 2 c/o (SPDT) contacts Versions with 3 c/o (SPDT) contacts<br>(CR-M ... 2) (CR-M ... 3)<br>Load limit curves - Electrical lifetime at resistive AC load<br>Switching power [kVA]<br>Switching power [kVA]<br>Versions with 2 c/o (SPDT) contacts Versions with 3 c/o (SPDT) contacts<br>(CR-M ... 2) (CR-M ... 3)<br>Reduction factor F at inductive AC load<br>Power factor<br>DC current [A] DC current [A]<br>2CDC 292 015 F0204 2CDC 292 019 F0204<br>Switching cycles Switching cycles<br>2CDC 292 013 F0204 2CDC 292 018 F0204<br>Reduction factor<br>2CDC 292 014 F0204<br>**----- End of picture text -----**<br> **==> picture [161 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> DC voltage [V]<br>Versions with 4 c/o (SPDT) contacts<br>(CR-M ... 4)<br>DC current [A]<br>2CDC 292 023 F0204<br>**----- End of picture text -----**<br> **==> picture [161 x 167] intentionally omitted <==** **----- Start of picture text -----**<br> Switching power [kVA]<br>Versions with 4 c/o (SPDT) contacts<br>(CR-M ... 4)<br>Switching cycles<br>2CDC 292 022 F0204<br>**----- End of picture text -----**<br> 10 - Pluggable interface relays CR-M | Data sheet Dimensions in mm **==> picture [233 x 421] intentionally omitted <==** **----- Start of picture text -----**<br> Versions with 2 c/o (SPDT) contacts (CR-M ... 2)<br>Versions with 3 c/o (SPDT) contacts (CR-M ... 3)<br>2CDC 292 001 F0015<br>2CDC 292 002 F0015<br>2CDC 292 003 F0015<br>**----- End of picture text -----**<br> Versions with 4 c/o (SPDT) contacts (CR-M ... 4) ## Further documentation **==> picture [511 x 75] intentionally omitted <==** **----- Start of picture text -----**<br> Document title Document type Document number<br>Electronic relays and controls Catalog 2CDC 110 004 C02xx<br>Sockets CR-M Data sheet 2CDC 117 005 D020x<br>Jumper bar CR-MJ Data sheet 2CDC 117 015 D020x<br>Pluggable function modules CR-P/M Data sheet 2CDC 117 007 D020x<br>**----- End of picture text -----**<br> - You can find the documentation on the internet at www.abb.com/lowvoltage -> Automation, control and protection -> Electronic relays and controls - -> Interface relays and optocouplers. ## CAD system files - You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com -> Low Voltage Products & Systems -> Control Products -> Electronic Relays and Controls. Data sheet | Pluggable interface relays CR-M - 11 ## Contact us ABB STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organization on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems ## Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB AG. Copyright© 2017 ABB All rights reserved
Updated at June 7, 2026
ABB is a global leader in power and automation technologies, recognized for delivering innovative solutions that improve performance while minimizing environmental impact. Serving a diverse range of sectors including industrial processing, OEM, and building services, ABB provides highly reliable components designed to meet the rigorous demands of modern electrical systems. The company is particularly renowned for its advanced circuit protection solutions. This includes a comprehensive selection of thermal magnetic circuit breakers, alongside specialized RCBO, RCD, GFCI, and AFDD circuit breakers. These foundational safety components are supported by a wide array of high-quality fuse holders and circuit breaker accessories, ensuring complete protection for complex industrial and commercial installations. Beyond circuit protection, ABB excels in automation and process control. Their offering features sophisticated visual signal indicator units, industrial switch accessories, and panel instrumentation designed for intuitive system monitoring. Additionally, ABB manufactures a robust range of power relays, safety relays, and AC/DC converters, providing engineers with the critical building blocks needed for efficient, secure, and reliable control panels.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →