1SVR405622R7100
Power Relay, Interface, 3PDT, 110 VAC, 10 A, CR-U Series, Socket, Non Latching
- Manufacturer: ABB
- Product type: Power Relays
- Contact Configuration:3PDT; Coil Voltage:110VAC; Contact Current:10A; Product Range:CR-U Series; Relay Mounting:Socket; Coil Type:Non Latching; Contact Voltage VAC:250V; Relay Termin
- SVHC: To Be Advised
- Coil Type: Non Latching
- Coil Voltage: 110VAC
- Product Range: CR-U Series
- Relay Mounting: Socket
- Coil Resistance: 1.7kohm
- Contact Current: 10A
- Relay Terminals: Quick Connect
- Contact Material: Silver Nickel
- Contact Voltage VAC: 250V
- Contact Voltage VDC: -
- Approvals & Standards: CSA, UL
- Contact Configuration: 3PDT
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 14.04 € |
| Current stock | 10+ |
| Lead time | 9 days |
**Pluggable interface relays CR-U Universal relays** Data sheet ## Features 1 ist 2 | (ez: 4 = —— tol 3 Standard universal relays with mechanical status indication 10 different supply voltages: DC versions: 12 V, 24 V, 48 V, 110 V, 125 V, 220 V AC versions: 24 V, 48 V, 60 V, 110 V, 120 V, 230 V Output: 2 c/o (SPDT) contacts (10 A) or 3 c/o (SPDT) contacts (10 A) Available with or without LED Integrated test button for manual operation and locking of output contacts (blue = DC, orange = AC), that can be removed if necessary Cadmium-free contact material Width on socket: 38 mm Pluggable function modules: reverse polarity protection/free wheeling diode, LED indication, RC elements, overvoltage protection, multifunction time module CR-U ## Approvals G UL508 Interface relay Pluggable function module Socket Holder O CAN/CSA C22.2 No.14 F CAN/CSA C22.2 No.14 J VDE D GOST P Lloyds Register E CCC L RMRS ## Marks a CE ## Order data |**Type**|**Rated control supply voltage US**|**Order code**| |---|---|---| |Interface relays without LED, 2 c/o (SPDT) contacts: 250 V, 10 A||| |CR-U012DC2|12 V DC|1SVR 405 621 R4000| |CR-U024DC2|24 V DC|1SVR 405 621 R1000| |CR-U048DC2|48 V DC|1SVR 405 621 R6000| |CR-U110DC2|110 V DC|1SVR 405 621 R8000| |CR-U220DC2|220 V DC|1SVR 405 621 R9000| |**CR-U024AC2**|**24 V AC**|**1SVR 405 621 R0000**| |CR-U048AC2|48 V AC|1SVR 405 621 R5000| |**CR-U110AC2**|**110 V AC**|**1SVR 405 621 R7000**| |CR-U120AC2|120 V AC|1SVR 405 621 R2000| |**CR-U230AC2**|**230 V AC**|**1SVR 405 621 R3000**| |Interface relays without LED, 3 c/o (SPDT) contacts: 250 V, 10 A||| |CR-U012DC3|12 V DC|1SVR 405 622 R4000| |**CR-U024DC3**|**24 V DC**|**1SVR 405 622 R1000**| |CR-U048DC3|48 V DC|1SVR 405 622 R6000| |CR-U110DC3|110 V DC|1SVR 405 622 R8000| |CR-U125DC3|125 V DC|1SVR 405 622 R8200| |CR-U220DC3|220 V DC|1SVR 405 622 R9000| |**CR-U024AC3**|**24 V AC**|**1SVR 405 622 R0000**| |CR-U048AC3|48 V AC|1SVR 405 622 R5000| |CR-U060AC3|60 V AC|1SVR 405 622 R5200| |**CR-U110AC3**|**110 V AC**|**1SVR 405 622 R7000**| |CR-U120AC3|120 V AC|1SVR 405 622 R2000| |**CR-U230AC3**|**230 V AC**|**1SVR 405 622 R3000**| Bold printed products = stocked products. Packing unit = 10 pieces. 1 **Pluggable interface relays CR-U Universal relays** Data sheet **==> picture [382 x 387] intentionally omitted <==** **----- Start of picture text -----**<br> Type Rated control supply voltage US Order code<br>Interface relays with LED<br>2 c/o (SPDT) contacts: 250 V, 10 A<br>CR-U012DC2L 12 V DC 1SVR 405 621 R4100<br>CR-U024DC2L 24 V DC 1SVR 405 621 R1100<br>CR-U048DC2L 48 V DC 1SVR 405 621 R6100<br>CR-U110DC2L 110 V DC 1SVR 405 621 R8100<br>CR-U220DC2L 220 V DC 1SVR 405 621 R9100<br>CR-U024AC2L 24 V AC 1SVR 405 621 R0100<br>CR-U048AC2L 48 V AC 1SVR 405 621 R5100<br>CR-U110AC2L 110 V AC 1SVR 405 621 R7100<br>CR-U120AC2L 120 V AC 1SVR 405 621 R2100<br>CR-U230AC2L 230 V AC 1SVR 405 621 R3100<br>Interface relays with LED<br>3 c/o (SPDT) contacts: 250 V, 10 A<br>CR-U012DC3L 12 V DC 1SVR 405 622 R4100<br>CR-U024DC3L 24 V DC 1SVR 405 622 R1100<br>CR-U048DC3L 48 V DC 1SVR 405 622 R6100<br>CR-U110DC3L 110 V DC 1SVR 405 622 R8100<br>CR-U220DC3L 220 V DC 1SVR 405 622 R9100<br>CR-U024AC3L 24 V AC 1SVR 405 622 R0100<br>CR-U048AC3L 48 V AC 1SVR 405 622 R5100<br>CR-U110AC3L 110 V AC 1SVR 405 622 R7100<br>CR-U120AC3L 120 V AC 1SVR 405 622 R2100<br>CR-U230AC3L 230 V AC 1SVR 405 622 R3100<br>Interface relays with LED and freewheeling diode<br>3 c/o (SPDT) contacts: 250 V, 10 A<br>CR-U024DC3LD 24 V DC 1SVR 405 623 R1100<br>**----- End of picture text -----**<br> ## Order data - Accessories ## Sockets **==> picture [381 x 144] intentionally omitted <==** **----- Start of picture text -----**<br> Type Version Order code<br>Sockets<br>CR-U2S for 2 c/o (SPDT) contacts + module 1SVR 405 670 R0000<br>CR-U3S for 3 c/o (SPDT) contacts + module 1SVR 405 660 R0000<br>CR-U3E for 3 c/o (SPDT) contacts 1SVR 405 660 R0100<br>Small sockets<br>CR-U2SM for 2 c/o (SPDT) contacts 1SVR 405 670 R1100<br>CR-U3SM for 3 c/o (SPDT) contacts 1SVR 405 660 R1100<br>Accessories for CR-U sockets<br>CR-UH Metall holder 1SVR 405 669 R0000<br>**----- End of picture text -----**<br> Bold printed products = stocked products. Packing unit = 10 pieces. 2 **Pluggable interface relays CR-U Universal relays** Data sheet ## Function modules **==> picture [382 x 467] intentionally omitted <==** **----- Start of picture text -----**<br> Type Rated control Version Order code<br>supply voltage US<br>Diode - Reverse polarity protection<br>CR-U 21 6-230 V DC A1+, A2- 1SVR 405 661 R0000<br>Diode and LED - Reverse polarity protection<br>CR-U 41 6-24 V DC red, A1+, A2- 1SVR 405 662 R0000<br>CR-U 41V 6-24 V DC green, A1+, A2- 1SVR 405 662 R1000<br>CR-U 41B 24-60 V DC red, A1+, A2- 1SVR 405 662 R4000<br>CR-U 41BV 24-60 V DC green, A1+, A2- 1SVR 405 662 R4100<br>CR-U 41C 110-230 V DC red, A1+, A2- 1SVR 405 662 R9000<br>CR-U 41CV 110-230 V DC green, A1+, A2- 1SVR 405 662 R9100<br>RC element - Arc elemination<br>CR-U 51B 6-24 V AC 1SVR 405 663 R0000<br>CR-U 51D 24-60 V AC 1SVR 405 663 R4000<br>CR-U 51C 110-230 V AC 1SVR 405 663 R1000<br>Diode and LED<br>CR-U 61 6-24 V AC/DC red, for DC: A1+, A2- 1SVR 405 664 R0000<br>CR-U 61V 6-24 V AC/DC green, for DC: A1+, A2- 1SVR 405 664 R1000<br>CR-U 61E 24-60 V AC/DC red, for DC: A1+, A2- 1SVR 405 664 R4000<br>CR-U 61EV 24-60 V AC/DC green, for DC: A1+, A2- 1SVR 405 664 R4100<br>CR-U 91 110-230 V AC/DC red, for DC: A1+, A2- 1SVR 405 664 R0100<br>CR-U 91V 110-230 V AC/DC green, for DC: A1+, A2- 1SVR 405 664 R1100<br>Varistor and LED - Overvoltage protection<br>CR-U 61C 6-24 V AC/DC red, for DC: A1+, A2- 1SVR 405 665 R0000<br>CR-U 61CV 6-24 V AC/DC green, for DC: A1+, A2- 1SVR 405 665 R1000<br>CR-U 61D 24-60 V AC/DC red, for DC: A1+, A2- 1SVR 405 665 R4000<br>CR-U 61DV 24-60 V AC/DC green, for DC: A1+, A2- 1SVR 405 665 R4100<br>CR-U 91C 110-230 V AC/DC red, for DC: A1+, A2- 1SVR 405 665 R0100<br>CR-U 91CV 110-230 V AC/DC green, for DC: A1+, A2- 1SVR 405 665 R1100<br>Varistor - Overvoltage protection<br>CR-U 71 24 V AC 1SVR 405 666 R0000<br>CR-U 71A 115 V AC 1SVR 405 666 R1000<br>CR-U 81 230 V AC 1SVR 405 666 R2000<br>**----- End of picture text -----**<br> ## Multifunction time module **==> picture [382 x 53] intentionally omitted <==** **----- Start of picture text -----**<br> Type Rated control supply voltage US Order code<br>Multifunction timer module<br>CR-U T 24-240 V AC/DC pluggable onto CR-U2S 1SVR 405 667 R0000<br>and CR-U3S<br>**----- End of picture text -----**<br> All CR-U modules can be plugged onto sockets CR-U2S and CR-U3S. Bold printed products = stocked products. Packing unit = 10 pieces. 3 ## **Pluggable interface relays CR-U Universal relays** Data sheet ## Application Interface relays are electromechanic and electronic input and output modules for electrical isolation, levelling, noise suppression or signal amplifi cation between control unit and process. ## Operating mode When power supply is applied, the output contacts get closed. When control supply voltage is switched off, the contacts fall back into their starting position. Manual operation and locking of the output relays is possible via the integrated test button. ## Connection diagrams **==> picture [104 x 130] intentionally omitted <==** **==> picture [5 x 49] intentionally omitted <==** **----- Start of picture text -----**<br> 2CDC 292 024 F0004<br>**----- End of picture text -----**<br> **CR-U with 2 c/o (SPDT) contacts** **==> picture [104 x 130] intentionally omitted <==** **==> picture [5 x 49] intentionally omitted <==** **----- Start of picture text -----**<br> 2CDC 292 030 F0004<br>**----- End of picture text -----**<br> **CR-U with 3 c/o (SPDT) contacts** A1-A2 Control supply voltage 11-12/14 Relay outputs 31-32/34 A1-A2 Control supply voltage 11-12/14 Relay outputs 21-22/24 31-32/34 ## Technical data ## **Input circuit - Coil data A1-A2** **==> picture [512 x 252] intentionally omitted <==** **----- Start of picture text -----**<br> Rated con- Rated Make Maxium Break Rated Coil Tolerance<br>trol supply frequency voltage voltage voltage power resistance of coil<br>voltage Us (at 20 °C) (at 55 °C) (at 20 °C) resistance<br>DC coils 12 V DC - 9.6 V DC 13.2 V DC � 0.1 Us 1.5 W 110 � � 10%<br>24 V DC - 19.2 V DC 26.4 V DC � 0.1 Us 1.5 W 430 � � 10%<br>48 V DC - 38.4 V DC 52.8 V DC � 0.1 Us 1.5 W 1750 � � 10%<br>110 V DC - 88.0 V DC 121.0 V DC � 0.1 Us 1.5 W 9200 � � 10%<br>125 V DC - 96.0 V DC 132,0 V DC � 0.1 Us 1.5 W 11000 � � 10%<br>220 V DC - 176.0 V DC 242.0 V DC � 0.1 Us 1.5 W 37000 � � 10%<br>AC coils 24 V AC 50 / 60 Hz 19.2 V AC 26.4 V AC � 0.15 Us 2.8 VA (50 Hz)2.5 VA (60 Hz) 75 � � 10%<br>48 V AC 50 / 60 Hz 38.4 V AC 52.8 V AC � 0.15 Us 2.8 VA (50 Hz)2.5 VA (60 Hz) 305 � � 10%<br>60 V AC 50 / 60 Hz 48.0 V AC 66,0 V AC � 0.15 Us 2.8 VA (50 Hz)2.5 VA (60 Hz) 475 � � 10%<br>110 V AC 50 / 60 Hz 88.0 V AC 121.0 V AC � 0.15 Us 2.8 VA (50 Hz)2.5 VA (60 Hz) 1700 � � 10%<br>120 V AC 50 / 60 Hz 96.0 V AC 132.0 V AC � 0.15 Us 2.8 VA (50 Hz)2.5 VA (60 Hz) 1910 � � 10%<br>230 V AC 50 / 60 Hz 184.0 V AC 253.0 V AC � 0.15 Us 2.8 VA (50 Hz)2.5 VA (60 Hz) 7080 � � 10%<br>**----- End of picture text -----**<br> 4 ## **Pluggable interface relays CR-U Universal relays** Data sheet **==> picture [511 x 688] intentionally omitted <==** **----- Start of picture text -----**<br> Type CR-U...2 CR-U...3<br>Output circuits 11-12/14, 31-32/34 11-12/14, 21-22/24, 31-32/34<br>Kind of output Relay, 2 c/o contacts Relay, 3 c/o contacts<br>Contact material AgNi<br>Rated operational voltage Ue (VDE 0110, IEC 60947-1) 250 V<br>Min. switching voltage 5 V<br>Max. switching voltage DC 250 V DC<br>AC 250 V AC<br>Min. switching current 5 mA<br>Conventional free-air thermal current Ith 10 A<br>Rated operational current AC12 (resistive) 230 V 10 A<br>(IEC 60947-5-1)<br>AC15 (inductive) 230 V 1.5 A<br>DC12 (resistive) 24 V 10 A<br>DC13 (inductive) 24 V 2 A<br>Max. making current 20 A<br>Min. switching power 0.3 W<br>Max. switching power AC1 2500 VA<br>Contact resistance � 100 m�<br>Max. switching capacity rated load AC1 1200 switching cycles / h<br>without load 12000 switching cycles / h<br>Lifetime mechanical � 2 x 10 [7] switching cycles<br>electrical AC1 (resistive) � 10 [5 ] switching cycles (10 A, 250 V)<br>cos ϕ see reduction factor F<br>Response time typ. 18 ms (DC) / typ. 12 ms (AC)<br>Release time typ. 7 ms (DC) / typ. 10 ms (AC)<br>Isolation data<br>Rated insulation voltage 250 V AC<br>Insulation class C250<br>Rated impulse withstand voltage Uimp between coil and contacts 2.5 kV AC<br>open contacts 1.5 kV AC<br>c/o (SPDT) contacts 2 kV AC<br>Clearance between coil and contacts � 3 mm<br>Creepage distance between coil and contacts � 4.2 mm<br>Overvoltage category III<br>Pollution degree 3<br>General data<br>Dimensions (W x H x D) when mounted 35 x 35 x 54.4 mm<br>Weight 83 g (0.18 lb)<br>Mounting on socket (see accessories)<br>Mounting position any<br>Degree of protection IP 40<br>Electrical connection<br>Connection by socket<br>Environmental data<br>Ambient temperature range operation DC -40...+70 °C<br>AC -40...+55 °C<br>storage -40...+85 °C<br>Vibration resistance (10-150 Hz) n/o contacts 5 g<br>n/c contacts 5 g<br>Shock resistance n/o contacts 10 g<br>n/c contacts 10 g<br>Standards<br>Product standards EN 60255-1-00<br>Low Voltage Directive 73/23/EEC<br>**----- End of picture text -----**<br> 5 **Pluggable interface relays CR-U Universal relays** Data sheet ## Technical diagrams Load limit curve - Maximum switching power at resistive DC load Load limit curve - Electrical lifetime at resistive AC load **==> picture [346 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> 1 = resistive load, T = 0 ms<br>2 = inductive load, T = 40 ms<br>DC voltage [V] Switching power [kVA]<br>DC current [A]<br>Switching cycles<br>2CDC 292 028 F0204 2CDC 292 037 F2004<br>**----- End of picture text -----**<br> ## Reduction factor F at inductive AC load **==> picture [151 x 260] intentionally omitted <==** **----- Start of picture text -----**<br> Power factor<br>Dimensions<br>Reduction factor<br>2CDC 292 029 F0204<br>2CDC 292 025 F0004<br>**----- End of picture text -----**<br> Versions with 2 c/o contacts (CR-U ... 2) **==> picture [144 x 66] intentionally omitted <==** **----- Start of picture text -----**<br> Versions with 3 c/o contacts (CR-U ... 3)<br>2CDC 292 026 F0004<br>**----- End of picture text -----**<br> ## in mm ## Further documentation **==> picture [382 x 73] intentionally omitted <==** **----- Start of picture text -----**<br> Document title Document type Document number<br>Sockets CR-U Data sheet 2CDC 117 006 D010x<br>Pluggable function modules CR-U Data sheet 2CDC 117 008 D010x<br>Pluggable multifunction time module CR-U T Data sheet 2CDC 117 010 D010x<br>**----- End of picture text -----**<br> 6 ## **** As part of the on-going product improvement, ABB reserves the right to modify the characteristics of the products described in this document. The information given is non-contractual. For further details please contact (www.abb.com/contacts) the ABB company marketing these products in your country. ## **ABB STOTZ-KONTAKT GmbH** Eppelheimer Strasse 82, 69123 Heidelberg, Germany Postfach 10 16 80, 69006 Heidelberg, Germany Internet http://www.abb.com/lowvoltage � Control Products Contact: http://www.abb.com/contacts � Low Voltage Products and Systems
Updated at April 28, 2026
ABB is a global leader in power and automation technologies, recognized for delivering innovative solutions that improve performance while minimizing environmental impact. Serving a diverse range of sectors including industrial processing, OEM, and building services, ABB provides highly reliable components designed to meet the rigorous demands of modern electrical systems. The company is particularly renowned for its advanced circuit protection solutions. This includes a comprehensive selection of thermal magnetic circuit breakers, alongside specialized RCBO, RCD, GFCI, and AFDD circuit breakers. These foundational safety components are supported by a wide array of high-quality fuse holders and circuit breaker accessories, ensuring complete protection for complex industrial and commercial installations. Beyond circuit protection, ABB excels in automation and process control. Their offering features sophisticated visual signal indicator units, industrial switch accessories, and panel instrumentation designed for intuitive system monitoring. Additionally, ABB manufactures a robust range of power relays, safety relays, and AC/DC converters, providing engineers with the critical building blocks needed for efficient, secure, and reliable control panels.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →