1SNL340010R0000
Panel Mount Barrier Terminal Block, 400 A, 1.5 kV, 1 Pole, 1, Screw
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TE CONNECTIVITY - ENTRELEC
- Product type: Power Distribution Blocks
- Rated Current:400A; Rated Voltage:1.5kV; No. of Poles:1 Pole; Line Side Connections Per Pole:1; Line Side Connection Method:Screw; Line Side Wire Size Max:-; Load Side Connections Per Pole:
- SVHC: Lead (25-Jun-2025)
- No. of Poles: 1 Pole
- Product Range: DBL400
- Rated Current: 400A
- Rated Voltage: 1.5kV
- Line Side Wire Size Max: -
- Load Side Wire Size Max: -
- Line Side Connection Method: Screw
- Load Side Connection Method: Screw
- Line Side Connections Per Pole: 1
- Load Side Connections Per Pole: 11
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 58.92 € |
| Current stock | 10+ |
| Lead time | 23 days |
## **DBL POWER DISTRIBUTION BLOCKS**
## ENTRELEC Terminal Blocks
INDUSTRIAL /// ENTRELEC - DBL POWER DISTRIBUTION BLOCKS
**DBL power distribution blocks**
## The clever distribution concept
The exclusive compact and modular design of our power distribution blocks allows easy installation combined with a great flexibility of use.
## Easy to install
- 3 configurations in 1 product:
Single pole splitter: split of power main input into several outputs Multiple poles splitter: interlocking function and ready to use marking kit (L1, L2, L3, N, PE, +, - ) delivered with each block Grouping: of several inputs into 1 output (solar application). Flexible cover facilitates identification & wiring:
- Reversible, two directions opening, snap-on
- All wiring data’s and specifications visible on top.
## Space saving
Panel space saving:
Save up to 50 % rail space compare to conventional distribution bars thanks to our modular compact design 1 500 V DC:
Voltage rating adapted to most recent solar inverters requirements.
## Increased productivity
- Reduced wiring, inventories, hardware and assembly costs:
- Reduce assembly time by 80 % compared to conventional systems.
- Our modular and touch proof concept eliminates the needs for bus bars, isolators, fasteners, protection screens…
- Accept aluminum & copper conductors
- 1 product in stock for 3 possible configurations.
**==> picture [182 x 423] intentionally omitted <==**
**----- Start of picture text -----**<br>
Splitter Group<br>Single pole Multiple pole<br>a ey<br>L1 L2 L3<br>! ! ! |<br>Bus bar<br>NV DBL @ 50%<br>space saving<br>1500 V DC<br>g<br>a)<br>—<br>|<br>eal<br>-80%<br>assembly<br>time<br>1SNC166009S0201 - Rev. D<br>**----- End of picture text -----**<br>
INDUSTRIAL /// ENTRELEC - DBL POWER DISTRIBUTION BLOCKS
**DBL power distribution blocks** 1 product, 2 applications
## Distributing power in industrial and commercial panels HVAC, machinery, power distribution unit (PDU), commercial panel
## 3 Phases
DBL80, DBL125, DBL160, DBL175, DBL250, DBL400, DBL125-3, DBL175-C-3
**==> picture [14 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1<br>L2<br>L3<br>**----- End of picture text -----**<br>
## 3 Phases for flat conductor
DBL250-F, DBL500-F
**==> picture [14 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1<br>L2<br>L3<br>**----- End of picture text -----**<br>
## 3 Phases with jumpering wire
DBL80, DBL125, DBL160, DBL175, DBL400-PV, DBL125-3, DBL175-C-3 and DBL500-22
**==> picture [14 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1<br>L2<br>L3<br>**----- End of picture text -----**<br>
2 in/2 out configuration DBL500-22
**==> picture [14 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1<br>**----- End of picture text -----**<br>
## Combining PV strings in one single output
PV combiner box, central inverter in a solar power plant
Up to 12 PV strings DBL80…400
DBL400-PV specifically designed for solar application with 12 inputs of 16 mm².
PAGE 3
**DBL power distribution blocks** Range overview
Single pole, solar, three poles, flat conductor and 2 in/2 out
**==> picture [517 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
Single pole<br>DBL80 DBL125 DBL160 DBL175 DBL250 and<br>7 connections DBL400<br>8 connections 8 connections 12 connections<br>12 connections<br>**----- End of picture text -----**<br>
**==> picture [508 x 94] intentionally omitted <==**
**----- Start of picture text -----**<br>
Panel or<br>DIN rail mounting<br>Easy block assembly ~~" . Easy jumpering Increase the number of (L1, L2, L3, N, PE, +, -) Pre-printed markers<br>thanks to the outputs by connecting delivered with each<br>interlocking piece f thse ams two blocks together block<br>**----- End of picture text -----**<br>
INDUSTRIAL /// ENTRELEC - DBL POWER DISTRIBUTION BLOCKS
## Solar
## Three poles
## Flat conductor
## 2 in/2 out
DBL400-PV DBL125-3 and DBL175-C-3 14 connections 8x3 connections
DBL250-F and DBL500-22 DBL500-F 4 connections 7 and 12 connections
x3
Flat conductor feed-in Combining Flexible cover for of 12 photovoltaic strings easy wiring: to collect solar energy up to • Two directions opening 1500 V DC (IEC), 1000 V DC (UL) • Removable & snap-on
Main technical data printed on the cover and visible from top
PAGE 5
**DBL power distribution blocks** Panorama
Single pole Input/ Output Round conductors See me. eS ~~OS~~ Number of connections | 7 8 8 12 12 12 Max current Cross section IEC ~~a~~ UL e Cu 80 A 80 A 16 mm² 4 AWG ~~jj~~ Al 63 A - 16 mm² - DBL80 ~~ee er a | aa|| oe | ||| |~~ Cu 125 A 115 A 35 mm² 2 AWG DBL125 Al 100 A - 35 mm² - ~~a~~ Cu 160 A 160 A 70 mm² 2/0 AWG DBL160 Al 135 A - 70 mm² - Cu 175 A 175 A 70 mm² 2/0 AWG DBL175 Al 135 A - 70 mm² - ~~a~~ Cu 250 A 255 A 120 mm² 250 Kcmil DBL250 Al 200 A - 120 mm² - Cu 400 A 335 A 185 mm² 400 Kcmil DBL400 Al 300 A - 185 mm² - ~~A~~ Cu ~~ee~~ 500 A ~~FO~~ 510 A 95 mm² 250 Kcmil Cu 550 A 400 A 95 mm² 250 Kcmil
**==> picture [469 x 214] intentionally omitted <==**
**----- Start of picture text -----**<br>
Flat conductors<br>Input:<br>Flat conductors<br>Output:<br>Round conductors<br>Number of connections 7 12<br>—<br>Max current Max cross section<br>|<br>IEC UL<br>Cu 250 A 250 A 15.5 x 7.5 mm e DBL250-F<br>e e | z | iy |<br>DBL500-F<br>Coming soon<br>i | | |<br>**----- End of picture text -----**<br>
INDUSTRIAL /// ENTRELEC - DBL POWER DISTRIBUTION BLOCKS
**==> picture [482 x 351] intentionally omitted <==**
**----- Start of picture text -----**<br>
Three poles 2 in/2 out Solar<br>8x3 8x3 4 14<br>[X3] [X3]<br>oo = a<br>DBL125-3<br>a<br>a<br>DBL175-C-3<br>a<br>a<br>a<br>a<br>DBL500-22<br>DBL400-PV<br>**----- End of picture text -----**<br>
PAGE 7
**DBL80 power distribution blocks** Single pole - 28.4 mm 1.11 in spacing
## Description
- 3 configurations: distribute unipolar and multipolar power lines, or combine several inputs
- Mount it on Din rail or plate and save up to 50% rail space compared to conventional copper bars
- Reduce the assembly time by 80% by avoiding to use fastening and isolating components
- Increase the number of outputs by using the optional input and connecting two DBL together
- Easy identification with the reversible cover and delivered pre-printed markers L1, L2, L3, N, PE, +, –.
**==> picture [4 x 36] intentionally omitted <==**
**----- Start of picture text -----**<br>
1SNC166026V0014<br>**----- End of picture text -----**<br>
## Ordering details
**==> picture [448 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Description|Color|Type|Part Number|Pkg|Weight|
|qty|1 pce|g|
|Feed-through|Single pole distribution, 7|Grey|DBL80|1SNL308010R0000|1|70|
|connections|
|Main technical data|
|Connecting capacity|IEC|UL|
|Max current / Cross section|Copper|80 A / 16 mm²|80 A / 4 AWG|
|Aluminium|63 A / 16 mm²|
|Rated voltage|1000 V AC / 1500 V DC|1000 V|
|Rated impulse voltage|8 kV|
|Short-time withstand current (Icw 1s)|1920 A|
|Short Circuit Current Rating|(SCCR)|100 kA|
|Rated peak withstand current (Ipk)|27 kA|
|Protection|IP20|NEMA 1|
|L_|The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA standards (Copper conductors). All other data are provided as supplementary information only. For more details, please consult our CB, UL or CSA|
|———————|
|i|a|certificates and technical datasheet available on http://www.TE.com|
|C€|BH|rox|WwW|EC|fi|2|
|CE|CB|RoHS|USR|CSA|EAC|BV|
**----- End of picture text -----**<br>
**==> picture [20 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
DBL80<br>**----- End of picture text -----**<br>
**==> picture [119 x 172] intentionally omitted <==**
**----- Start of picture text -----**<br>
L_<br>us<br>i<br>36.3 1.43"<br>a<br>66 2.6"<br>53 2.09" 5 0.2"<br>9.5 x 5.5 mm 11.5 x 5.5 mm<br>0.37 x 0.22" 0.45 x 0.22"<br>28.4 mm 1.11 in spacing<br> 1.01" 0.72"<br>25.7 18.2 1.98" 2.33" 2.04"<br>59.2 51.7<br>50.2<br>16.7 0.66"<br> 1.12" 14.8 0.58" 10.7 0.42"<br>28.4<br>**----- End of picture text -----**<br>
## Mounting & wiring instructions
**==> picture [374 x 171] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|TH 35-7.5,|
|Rail|
|TH 35-15|
|Connection|Wire type|Wire stripping length|Tool|Torque|
|Number|Size|
|Input|
|Ø 6.6 mm|2.5 ... 16 mm²|2.5 ... 16 mm²|15 mm|5.5 mm|1.5 ... 2 Nm|
|3|x|
|Ø 0.26 in|14 ... 6 AWG|14 ... 4 AWG|0.59 in|0.22 in|13.5 ... 18 lb.in|
|Output|4|x|Ø 4.5 mmØ 0.18 in|2.5 ... 6 mm²14 ... 10 AWG|2.5 ... 6 mm²14 ... 10 AWG|11 mm0.43 in|0.16 in4 mm|7.2 ... 10.8 lb.in0.8 ... 1.2 Nm|
|[|.]|:|@|||
|Not allowed|Flexible with ferrule|Solid|Rigid stranded|
|Flexible without ferrule|(IEC V-K, UL class G…K)|(IEC V-U class 1, UL solid)|(IEC V-R class 2, UL class B/C)|
|(IEC V-K, UL class G…K)|
|[Allen key]|[Posidriv - flat screwdriver]|
**----- End of picture text -----**<br>
Mounting instructions
**==> picture [29 x 114] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.5 mm 0.22"<br>PZ2<br>Dy)<br>4 mm 0.16"<br>PZ1<br>**----- End of picture text -----**<br>
## Accessories
**==> picture [63 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2<br>**----- End of picture text -----**<br>
**==> picture [380 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Description|Color|Type|Part Number|—|Pkg|Weight|
|qty|1 pce|g|
|1|End stops|10 mm|0.394 in|Dark grey|BAM4|1SNK900001R0000|50|14.00|
|5.2 mm|0.205 in|BAZ1|1SNK900002R0000|50|5.30|
|10 mm|0.394 in|BAZH1|1SNK900102R0000|20|24.00|
|2|Terminal block|Blank marker|White|MG-CPM 13 41790|1SNB041790R0512|1960|0.236|
|markers|Blank card|Green|MC512PA-GN|1SNK149997R0000|20|10.00|
|Blue|MC512PA-BL|1SNK149998R0000|20|10.00|
|White|MC512PA|1SNK149999R0000|20|10.00|
|Pre-printed marker card|MC512PA|1SNK149002R0000|1|10.00|
|(L1-L2-L3-N-PE)|
**----- End of picture text -----**<br>
Complete list of accessories is indicated in the terminal block datasheet including end stops. Some accessories such as jumper bars may modify the terminal block's ratings: Complete information available in the accessories section of the catalog.
INDUSTRIAL /// ENTRELEC - DBL POWER DISTRIBUTION BLOCKS
**DBL125 power distribution blocks** Single pole - 28.2 mm 1.11 in spacing
## Description
- 3 configurations: distribute unipolar and multipolar power lines, or combine several inputs
- Mount it on Din rail or plate and save up to 50% rail space compared to conventional copper bars
- Reduce the assembly time by 80% by avoiding to use fastening and isolating components
- Increase the number of outputs by using the optional input and connecting two DBL together
- Easy identification with the reversible cover and delivered pre-printed markers L1, L2, L3, N, PE, +, –.
## Ordering details
**==> picture [380 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Description|Color|Type|Part Number|Pkg|Weight|
|qty|1 pce|g|
|Feed-through|Single pole distribution, 8|Grey|DBL125|1SNL312510R0000|1|122|
|connections|
|Main technical data|
|Connecting capacity|IEC|UL|
|Max current / Cross section|Copper|125 A / 35 mm²|115 A / 2 AWG|
|Aluminium|100 A / 35 mm²|
|Rated voltage|1000 V AC / 1500 V DC|1000 V|
|Rated impulse voltage|8 kV|
|Short-time withstand current (Icw 1s)|4200 A|
|Short Circuit Current Rating|(SCCR)|100 kA|
|Rated peak withstand current (Ipk)|30 kA|
|Protection|IP20|NEMA 1|
**----- End of picture text -----**<br>
**==> picture [22 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
DBL125<br>**----- End of picture text -----**<br>
**==> picture [113 x 169] intentionally omitted <==**
**----- Start of picture text -----**<br>
36.3 1.43"<br>of Se<br>75 2.95"<br>62 2.44" 5 0.2"<br>9.5 x 5.5 mm 12 x 5.5 mm<br>0.37 x 0.22" 0.47 x 0.22"<br>28.2 mm 1.11 in spacing<br> 1.28"<br> 0.98"<br>32.5 25<br> 2" 2.35" 2.06"<br>50.7 59.8 52.3<br>23.5 0.93"<br> 1.11" 14.7 0.58"<br>28.2 10.7 0.42"<br>**----- End of picture text -----**<br>
**==> picture [379 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA|
|standards (Copper conductors). All other data are provided as supplementary information only. For more details, please consult our CB, UL or CSA|
|certificates and technical datasheet available on http://www.TE.com|
|CE|CB|RoHS|USR|CSA|EAC|BV|
**----- End of picture text -----**<br>
## Mounting & wiring instructions
**==> picture [496 x 367] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|TH 35-7.5,|
|Rail|
|TH 35-15|
|Connection|Wire type|Wire stripping length|Tool|Torque|
|9.5 x 5.5 mm|12 x 5.5 mm|Number|Size|
|0.37 x 0.22"|0.47 x 0.22"|||&|oe|iG|
|Input|
|Ø 9.8 mm|10 ... 35 mm²|10 ... 35 mm²|15 mm|4 mm|3.5 ... 5 Nm|
|Mounting instructions|1|x|
|Ø 0.39 in|8 ... 2 AWG|8 ... 2 AWG|0.59 in|0.16 in|31 ... 44 lb.in|
|4 mm|0.16"|Output|1|x|Ø 6.8 mmØ 0.27 in|2.5 ... 16 mm²14 ... 6 AWG|6 ... 16 mm²10 ... 6 AWG|11 mm0.43 in|0.12 in3 mm|18 ... 26.5 lb.in2 ... 3 Nm|
|Ø 6.4 mm|2.5 ... 16 mm²|2.5 ... 16 mm²|11 mm|5.5 mm|2 ... 3 Nm|
|3 mm|0.12"|6|x|
|Ø 0.25 in|14 ... 6 AWG|14 ... 6 AWG|0.43 in|0.22 in|18 ... 26.5 lb.in|
|a|FZ|i|When using maximum cable size with insulated ferrules, use a maximum of 2 non-adjacent holes in each row.|
|Not allowed|Flexible with ferrule|Solid|Rigid stranded|
|Flexible without ferrule|(IEC V-K, UL class G…K)|(IEC V-U class 1, UL solid)|(IEC V-R class 2, UL class B/C)|
|(IEC V-K, UL class G…K)|
|[Allen key]|[Posidriv - flat screwdriver]|
|5.5 mm|0.22"|
|nis|\3|PZ2|
|ALccecccececel|Accessories|
|2|Description|Color|Type|Part Number|:|Pkg|:|Weight|
|qty|1 pce|g|
|1|End stops|10 mm|0.394 in|Dark grey|BAM4|1SNK900001R0000|50|14.00|
|5.2 mm|0.205 in|BAZ1|1SNK900002R0000|50|5.30|
|10 mm|0.394 in|BAZH1|1SNK900102R0000|20|24.00|
|2|Terminal block|Blank marker|White|MG-CPM 13 41790|1SNB041790R0512|1960|0.236|
|markers|Blank card|Green|MC512PA-GN|1SNK149997R0000|20|10.00|
|Blue|im|MC512PA-BL|1SNK149998R0000|—_|20|10.00|
|White|MC512PA|1SNK149999R0000|20|10.00|
|Pre-printed marker card|MC512PA|1SNK149002R0000|1|10.00|
|(L1-L2-L3-N-PE)|
**----- End of picture text -----**<br>
## Mounting instructions
**==> picture [63 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2<br>**----- End of picture text -----**<br>
Complete list of accessories is indicated in the terminal block datasheet including end stops. Some accessories such as jumper bars may modify the terminal block's ratings: Complete information available in the accessories section of the catalog.
PAGE 9
**DBL125-3 power distribution blocks** 3x1 pole - 84.6 mm 3.33 in spacing
## Description
- The usage of three poles distribution block is recommended for L1, L2, L3 applications
**==> picture [118 x 344] intentionally omitted <==**
**----- Start of picture text -----**<br>
[X3]<br>)<br>DBL125-3<br>us<br>36.3 1.43"<br>1<br>75 2.95"<br>62 2.44" 5 0.2"<br>ai i m ‘<br>1SNC166049V0014<br> 1.28"<br> 0.98"<br>32.5 25<br> 2" 2.35"<br>50.7 59.8<br>23.5 0.93"<br>= =<br>=<br>= =<br> 3.33" =<br>84.6<br> 1.11" 14.7 0.58"<br>28.2 10.7 0.42"<br>**----- End of picture text -----**<br>
- Each pole can be separated from the assembly to align the poles with upstream equipment configuration
- Mount it on Din rail or plate and save up to 50% rail space compared to conventional copper bars
- Reduce the assembly time by 80% by avoiding to use fastening and isolating components
- Easy identification with the reversible cover and delivered pre-printed markers L1, L2, L3, N, PE, +, –.
|Orderingdetails<br>Description<br>Feed-through<br>Three poles distribution block 3x8<br>connections|Orderingdetails<br>Description<br>Feed-through<br>Three poles distribution block 3x8<br>connections|Color<br>Grey|Color<br>Grey|||Type<br>DBL125-3|Part Number<br>1SNL312530R0000|Part Number<br>1SNL312530R0000||Pkg<br>qty<br>1|Weight<br>1 pce g<br>367|
|---|---|---|---|---|---|---|---|---|---|---|---|
|Main technical data||||||||||||
|Connectingcapacity|||IEC|||||UL||||
|Max current / Cross section|Copper||125 A / 35 mm²|||||115 A / 2 AWG||||
||Aluminium||100 A / 35 mm²|||||||||
|Rated voltage<br>Rated impulse voltage<br>Short-time withstand current(Icw 1s)<br>Short Circuit Current Rating (SCCR)<br>Ratedpeak withstand current(Ipk)<br>Protection|||1000 V AC / 1500 V DC<br>8 kV<br>4200 A<br>30 kA<br>IP20|||||1000 V<br>NEMA 1||||
**==> picture [28 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
DBL125-3<br>**----- End of picture text -----**<br>
**==> picture [12 x 25] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.35" 2.06"<br>59.8 52.3<br>**----- End of picture text -----**<br>
The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA us J) ) standards (Copper conductors). All other data are provided as supplementary information only. For more details, please consult our CB, UL or CSA ) 36.3 _1.43"_ certificates and technical datasheet available on http://www.TE.com ~~1 a~~ C€ BE RoHS DW G fil CE CB RoHS USR CSA EAC
Mounting & wiring instructions
|Rail<br>TH 35-7.5,<br>TH 35-15<br>~~u~~|TH 35-7.5,||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Connection<br>Number<br>by pole<br>Size<br>**Input**<br>1 x<br>Ø 9.8 mm<br>Ø 0.39 in<br>~~y~~<br>|||Wire type<br>10 ... 35 mm²<br>8 ... 2 AWG||||||||10 ... 35 mm²<br>8 ... 2 AWG||||Wire stripping length<br>Tool<br>15 mm<br>0.59 in<br>©|||||4 mm<br>0.16 in||||Torque<br>3.5 ... 5 Nm<br>31 ... 44 lb.in|
|**Output**<br>1 x<br>Ø 6.8 mm<br>Ø 0.27 in<br>6 x<br>Ø 6.4 mm<br>Ø 0.25 in<br>When using maximum cable size with insulated ferrules, use a maximum of 2 non-adjacent holes in each row.||2.5 ... 16 mm²<br>6 ... 16 mm²<br>11 mm<br>14 ... 6 AWG<br>10 ... 6 AWG<br>0.43 in<br>2.5 ... 16 mm²<br>2.5 ... 16 mm²<br>11 mm<br>14 ... 6 AWG<br>14 ... 6 AWG<br>0.43 in<br>When using maximum cable size with insulated ferrules, use a maximum of 2 non-adjacent holes in each row.|||||||||||||||3 mm<br>0.12 in<br>5.5 mm<br>0.22 in|||2 ... 3 Nm<br>18 ... 26.5 lb.in<br>2 ... 3 Nm<br>18 ... 26.5 lb.in|
|**Not allowed**<br>Flexible with ferrule|Flexible with ferrule|Flexible with ferrule||||||Solid|Solid||Rigid stranded|Rigid stranded|Rigid stranded||||||||
|Flexible without ferrule<br>(IEC V-K, UL class G…K)<br>(IEC V-K, UL class G…K)<br> Allen key<br> Posidriv - flat screwdriver<br>~~©~~<br>~~@~~|||||||(IEC V-U class 1, UL solid)||(IEC V-U class 1, UL solid)|(IEC V-R class 2, UL class B/C)||(IEC V-R class 2, UL class B/C)|||||||||
9.5 x 5.5 mm 12 x 5.5 mm _0.37 x 0.22" 0.47 x 0.22"_ 84.6 mm 3.33 in spacing
Mounting instructions
5.5 mm _0.22"_ @ PZ2 eo 3 mm _0.12"_ e 4 mm _0.16"_ IPCCEECEGCCLONE 1 2
## Accessories
|Accessories|||||||
|---|---|---|---|---|---|---|
|Description|Color|Type|Part Number||Pkg<br>qty|Weight<br>1 pce g|
|1<br>End stops<br>10 mm<br>0.394 in<br>5.2 mm<br>0.205 in<br>10 mm<br>0.394 in|Dark grey<br>~~Oo~~|BAM4|1SNK900001R0000||50|14.00|
|||BAZ1|1SNK900002R0000||50|5.30|
|||BAZH1<br>~~Oo~~<br>~~,~~|1SNK900102R0000<br>~~,~~|~~_~~|20<br>~~_~~|24.00<br>~~_~~|
|2<br>Terminal block<br>markers<br>Blank marker<br>Blank card<br>Pre-printed marker card<br>(L1-L2-L3-N-PE)|White<br>~~Oo~~|MG-CPM 13 41790 <br>~~Oo~~<br>~~,~~|1SNB041790R0512<br>~~,~~|~~_~~|1960<br>~~_~~|0.236<br>~~_~~|
||Green<br>~~Oo~~|MC512PA-GN<br>~~Oo~~<br>~~,~~|1SNK149997R0000<br>~~,~~|~~_~~|20<br>~~_~~|10.00<br>~~_~~|
||Blue|MC512PA-BL|1SNK149998R0000||20|10.00|
||White|MC512PA|1SNK149999R0000||20|10.00|
|||MC512PA|1SNK149002R0000||1|10.00|
Complete list of accessories is indicated in the terminal block datasheet including end stops. Some accessories such as jumper bars may modify the terminal block's ratings: Complete information available in the accessories section of the catalog.
INDUSTRIAL /// ENTRELEC - DBL POWER DISTRIBUTION BLOCKS
**DBL160 power distribution blocks** Single pole - 28.2 mm 1.11 in spacing
## Description
- 3 configurations: distribute unipolar and multipolar power lines, or combine several inputs
- Mount it on Din rail or plate and save up to 50% rail space compared to conventional copper bars
- Reduce the assembly time by 80% by avoiding to use fastening and isolating components
- Increase the number of outputs by using the optional input and connecting two DBL together
- Easy identification with the reversible cover and delivered pre-printed markers L1, L2, L3, N, PE, +, –.
**==> picture [4 x 36] intentionally omitted <==**
**----- Start of picture text -----**<br>
1SNC166028V0014<br>**----- End of picture text -----**<br>
## Ordering details
|||||1SNC166028V0014|Description<br>Color<br>Type<br>Part Number<br>Pkg<br>qty<br>Feed-through<br>Single pole distribution, 8<br>connections<br>Grey<br>DBL160<br>1SNL316010R0000<br>1||Weight<br>1 pce g<br>120|
|---|---|---|---|---|---|---|---|
||||||Main technical data|||
||||||Connectingcapacity<br>IEC<br>UL|||
||||||Max current / Cross section<br>Copper<br>160 A / 70 mm²<br>160 A / 2/0 AWG|||
||||||Aluminium<br>135 A / 70 mm²|||
|52.3_2.06"_<br>59.8_2.35"_<br>50.7_2"_<br>[3|||||Rated voltage<br>1000 V AC / 1500 V DC<br>1000 V<br>Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>6000 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>30 kA<br>Protection<br>IP10<br>NEMA 1<br>The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA<br>standards (Copper conductors). All other data are provided as supplementary information only. For more details, please consult our CB, UL or CSA<br>certificates and technical datasheet available on http://www.TE.com<br> ~~SSS~~<br>~~SSO~~|||
||||||CE<br>CB<br>RoHS<br>USR<br>CSA<br>EAC<br>BV|||
**==> picture [22 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
DBL160<br>**----- End of picture text -----**<br>
**==> picture [113 x 169] intentionally omitted <==**
**----- Start of picture text -----**<br>
7 [3<br>36.3 1.43"<br>|<br>75 2.95"<br>62 2.44" 5 0.2"<br>0 a<br>9.5 x 5.5 mm 12 x 5.5 mm<br>0.37 x 0.22" 0.47 x 0.22"<br>28.2 mm 1.11 in spacing<br> 1.28"<br> 0.98"<br>32.5 25<br> 2" 2.35" 2.06"<br>50.7 59.8 52.3<br>23.5 0.93"<br> 1.11" 14.7 0.58"<br>28.2 10.7 0.42"<br>**----- End of picture text -----**<br>
## Mounting & wiring instructions
|Rail|||TH 35-7.5,<br>TH 35-15|TH 35-7.5,<br>TH 35-15|TH 35-7.5,<br>TH 35-15|TH 35-7.5,<br>TH 35-15|TH 35-7.5,||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||||||||||||||
|Connection||||||||Wire type||||||||Wire stripping length||||Tool||Torque|
|Number||Size|||||||||||||||||||||
||||||||||||||||||||||||
|**Input**|||||||||||||||||||||||
|1|x|Ø 11.8 mm<br>Ø 0.46 in||||||16 ... 50 mm²<br>6 ... 1/0 AWG||||||16 ... 70 mm²<br>6 ... 2/0 AWG||18 mm<br>0.708 in|||||5 mm<br>0.20 in|6... 10 Nm<br>53 ... 88 lb.in|
|**Output**<br>1|x|Ø 6.8 mm<br>Ø 0.27 in||||||2.5 ... 16 mm²<br>14 ... 6 AWG||||||6 ... 16 mm²<br>10 ... 6 AWG||11 mm<br>0.43 in|||||3 mm<br>0.12 in|2 ... 3 Nm<br>18 ... 26.5 lb.in|
|6|x|Ø 6.4 mm<br>Ø 0.25 in||||||2.5 ... 16 mm²<br>14 ... 6 AWG||||||2.5 ... 16 mm²<br>14 ... 6 AWG||11 mm<br>0.43 in|||||5.5 mm<br>0.22 in|2 ... 3 Nm<br>18 ... 26.5 lb.in|
|When using maximum cable size with insulated ferrules, use a maximum of 2 non-adjacent holes in each row.||||When using maximum cable size with insulated ferrules, use a maximum of 2 non-adjacent holes in each row.||||When using maximum cable size with insulated ferrules, use a maximum of 2 non-adjacent holes in each row.|||||||||||||||
|**Not allowed**|**Not allowed**||||||Flexible with ferrule|Flexible with ferrule||||||Solid||Rigid stranded|Rigid stranded||||||
|Flexible without ferrule|||(IEC V-K, UL class G…K)|||||(IEC V-K, UL class G…K)|||||(IEC V-U class 1, UL solid)||(IEC V-R class 2, UL class B/C)||||||||
|(IEC V-K, UL class G…K)|||||||||||||||||||||||
|Allen key||Posidriv - flat screwdriver|||||||||||||||||||||
## Mounting instructions
**==> picture [38 x 102] intentionally omitted <==**
**----- Start of picture text -----**<br>
5 mm 0.2"<br>3 mm 0.12"<br>5.5 mm 0.22"<br>PZ2<br>**----- End of picture text -----**<br>
## Accessories
**==> picture [63 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2<br>**----- End of picture text -----**<br>
|Accessories|||||||
|---|---|---|---|---|---|---|
|Description|Color|Type|Part Number||Pkg<br>qty|Weight<br>1 pce g|
|1<br>End stops<br>10 mm<br>0.394 in<br>5.2 mm<br>0.205 in<br>10 mm<br>0.394 in|Dark grey|BAM4|1SNK900001R0000||50|14.00|
|||BAZ1|1SNK900002R0000||50|5.30|
|||BAZH1|1SNK900102R0000||20|24.00|
|2<br>Terminal block<br>markers<br>Blank marker<br>Blank card<br>Pre-printed marker card<br>(L1-L2-L3-N-PE)|White|MG-CPM 13 41790|1SNB041790R0512||1960|0.236|
||Green|MC512PA-GN|1SNK149997R0000||20|10.00|
||Blue|MC512PA-BL|1SNK149998R0000||20|10.00|
||White|MC512PA|1SNK149999R0000||20|10.00|
|||MC512PA|1SNK149002R0000||1|10.00|
Complete list of accessories is indicated in the terminal block datasheet including end stops. Some accessories such as jumper bars may modify the terminal block's ratings: Complete information available in the accessories section of the catalog.
PAGE 11
**DBL175 power distribution blocks** Single pole - 46.2 mm 1.82 in spacing
## Description
- Reduce the assembly time by 80% by avoiding to use fastening and isolating components
- Mount it on Din rail or plate and save up to 50% rail space compared to conventional copper bars
- Increase the number of outputs by using the optional input and connecting two DBL together, or increase the current rating with two wires, 300 A with 50 mm² wires and 350 A with 2/0 AWG wires
- Easy identification with the reversible cover and delivered pre-printed markers L1, L2, L3, N, PE, +, –.
**==> picture [4 x 36] intentionally omitted <==**
**----- Start of picture text -----**<br>
1SNC166029V0014<br>**----- End of picture text -----**<br>
DBL175
**==> picture [119 x 185] intentionally omitted <==**
**----- Start of picture text -----**<br>
, 3)<br>us<br>30.4 1.2"<br>72.5 2.85"<br>4.7 0.19" 61 2.4"<br>4ee7<br>10.5 x 5 mm 11.5 x 5.5 mm<br>0.41 x 0.2" 0.45 x 0.22"<br>46.2 mm 1.81 in spacing<br> 1.28"<br> 0.98"<br>32.5 25<br> 2.06" 2.41" 2.12"<br>52.3 61.3 53.8<br>23.5 0.93"<br>14.9 0.59"<br>23.5 0.93"<br> 1.82"<br>17.6 0.69"<br>46.2<br>**----- End of picture text -----**<br>
## Mounting instructions
5 mm 0.2"
## Ordering details
|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|Description<br>Feed-through<br>Single pole distribution, 12<br>connections||Color<br>Grey||||Type<br>DBL175|Part Number<br>1SNL317510R0000|||Pkg<br>qty<br>1|Weight<br>1 pce g<br>200|
|Main technical data||||||||||||
|Connectingcapacity<br>Max current / Cross section|Copper||IEC<br>175 A / 70 mm²|||||UL<br>175 A / 2/0 AWG||||
||Aluminium||135 A / 70 mm²|||||||||
|Rated voltage|||1000 V AC / 1500 V DC|||||1000 V||||
|Rated impulse voltage<br>Short-time withstand current(Icw 1s)<br>Short Circuit Current Rating (SCCR)<br>Ratedpeak withstand current(Ipk)<br>Protection|||8 kV<br>6000 A<br>30 kA<br>IP10|||||100 kA<br>NEMA 1||||
The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA standards (Copper conductors). All other data are provided as supplementary information only. For more details, please consult our CB, UL or CSA certificates and technical datasheet available on http://www.TE.com
|CE||CB<br>RoHS<br>USR|CB<br>RoHS<br>USR||CSA|CSA||||EAC|EAC||||||BV||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Mounting& wiringinstructions<br>Rail<br>TH 35-7.5,<br>TH 35-15<br>Connection<br>Wire type<br>Number<br>Size<br>~~u~~|||||||||||~~7)~~||,||Wire stripping length<br>4||||Tool||Torque<br>~~©~~||
|**Input**|||||||||||||||||||||||
|2 <br>**Output**<br>10|x<br> x|Ø 11.8 mm<br>Ø 0.46 in<br>Ø 6.4 mm<br>Ø 0.25 in|||10 ... 50 mm²<br>8 ... 1/0 AWG<br>2.5 ... 16 mm²<br>14 ... 6 AWG|||||||10 ... 70 mm²<br>6 ... 2/0 AWG<br>2.5 ... 16 mm²<br>14 ... 6 AWG|||15 mm<br>0.708 in<br>11 mm<br>0.43 in|||||5 mm<br>0.20 in<br>5.5 mm<br>0.22 in||6... 10 Nm<br>53 ... 88 lb.in<br>2 ... 3 Nm<br>18 ... 26.5 lb.in|
||||||||||||||||||||||||
||||||||||||||||||||||||
|**Not allowed**|**Not allowed**|||Flexible with ferrule|Flexible with ferrule|||||||Solid||Rigid stranded|Rigid stranded|Rigid stranded|||||||
|Flexible without ferrule||Flexible without ferrule<br>(IEC V-K, UL class G…K)|||(IEC V-K, UL class G…K)||||||(IEC V-U class 1, UL solid)||(IEC V-R class 2, UL class B/C)||(IEC V-R class 2, UL class B/C)||||||||
|(IEC V-K, UL class G…K)<br> Allen key<br> Posidriv - flat screwdriver<br>©<br>@|||||||||||||||||||||||
**==> picture [30 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.5 mm 0.22"<br>PZ2<br>**----- End of picture text -----**<br>
**==> picture [50 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Accessories<br>**----- End of picture text -----**<br>
**==> picture [63 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2<br>**----- End of picture text -----**<br>
|Accessories|||||||
|---|---|---|---|---|---|---|
|Description|Color|Type|Part Number||Pkg<br>qty|Weight<br>1 pce g|
|1<br>End stops<br>10 mm<br>0.394 in<br>5.2 mm<br>0.205 in<br>10 mm<br>0.394 in|Dark grey|BAM4|1SNK900001R0000||50|14.00|
|||BAZ1|1SNK900002R0000||50|5.30|
|||BAZH1|1SNK900102R0000||20|24.00|
|2<br>Terminal block<br>markers<br>Blank marker<br>Blank card<br>Pre-printed marker card<br>(L1-L2-L3-N-PE)|White|MG-CPM 13 41790|1SNB041790R0512||1960|0.236|
||Green|MC512PA-GN|1SNK149997R0000||20|10.00|
||Blue|MC512PA-BL|1SNK149998R0000||20|10.00|
||White|MC512PA|1SNK149999R0000||20|10.00|
|||MC512PA|1SNK149002R0000||1|10.00|
Complete list of accessories is indicated in the terminal block datasheet including end stops. Some accessories such as jumper bars may modify the terminal block's ratings: Complete information available in the accessories section of the catalog.
INDUSTRIAL /// ENTRELEC - DBL POWER DISTRIBUTION BLOCKS
**DBL175-C-3 power distribution blocks** 3x1 pole - 84.6 mm 3.33 in spacing
## Description
**==> picture [14 x 13] intentionally omitted <==**
**----- Start of picture text -----**<br>
[X3]<br>**----- End of picture text -----**<br>
- The usage of three poles distribution block is recommended for L1, L2, L3 applications
- Each pole can be separated from the assembly to align the poles with upstream equipment configuration
- Mount it on Din rail or plate and save up to 50% rail space compared to conventional copper bars
- Reduce the assembly time by 80% by avoiding to use fastening and isolating components
- Easy identification with the reversible cover and delivered pre-printed markers L1, L2, L3, N, PE, +, –.
**==> picture [127 x 318] intentionally omitted <==**
**----- Start of picture text -----**<br>
DBL175-C-3<br>36.3 1.43"<br>1<br>75 2.95"<br>62 2.44" 5 0.2"<br>| h<br>ils Re<br>9.5 x 5.5 mm 12 x 5.5 mm<br>0.37 x 0.22" 0.47 x 0.22"<br>84.6 mm 3.33 in spacing<br>1SNC166050V0014<br> 1.28"<br> 0.98"<br>32.5 25<br> 2" 2.35" 2.06"<br>50.7 59.8 52.3<br>23.5 0.93"<br>= =<br>=<br>= =<br> 3.33" =<br>84.6<br> 1.11" 14.7 0.58"<br>28.2 10.7 0.42"<br>**----- End of picture text -----**<br>
Mounting instructions
## Ordering details
|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Description<br>Feed-through<br>Three poles distribution block 3x8<br>connections||Color<br>Grey|||||Type<br>DBL175-C-3|Part Number<br>1SNL317531R0000|||Pkg<br>qty<br>1||Weight<br>1 pce g<br>360|
|Main technical data||||||||||||||
|Connectingcapacity|||IEC||||||UL|||||
|Max current / Cross section<br>Copper|||175 A / 70 mm²||||||175 A / 2/0 AWG|||||
|Aluminium|||135 A / 70 mm²|||||||||||
|Rated voltage<br>Rated impulse voltage<br>Short-time withstand current(Icw 1s)<br>Short Circuit Current Rating (SCCR)<br>Ratedpeak withstand current(Ipk)<br>Protection<br>The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA|||1000 V AC / 1500 V DC<br>8 kV<br>6000 A<br>30 kA<br>IP10<br>The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA|||||1000 V<br>NEMA 1<br>The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA||||The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA||
|standards (Copper conductors). All other data are provided as supplementary information only. For more details, please consult our CB, UL or CSA<br>certificates and technical datasheet available on http://www.TE.com||||||||||||||
|CE<br>CB<br>RoHS<br>USR<br>CSA<br>EAC||||||||||||||
## Mounting & wiring instructions
|Rail<br>TH 35-7.5,<br>TH 35-15<br>Us|Rail<br>TH 35-7.5,<br>TH 35-15<br>Us|TH 35-7.5,|TH 35-7.5,||||
|---|---|---|---|---|---|---|
|Connection<br>Number<br>by pole<br>Size||Wire type||Wire stripping length|Tool|Torque|
|by pole<br>**Input**<br>1 x<br>Ø 11.8 mm<br>Ø 0.46 in<br>~~y~~|Ø 11.8 mm<br>Ø 0.46 in|16 ... 50 mm²<br>8 ... 1/0 AWG<br>|<br>||16 ... 70 mm²<br>6 ... 2/0 AWG<br>||18 mm<br>0.708 in<br>|<br>©|5 mm<br>0.20 in<br>©<br>||6... 10 Nm<br>53 ... 88 lb.in<br>||
|**Output**<br>1 x<br>Ø 6.8 mm<br>Ø 0.27 in<br>6 x<br>Ø 6.4 mm<br>Ø 0.25 in|Ø 6.8 mm<br>Ø 0.27 in|2.5 ... 16 mm²<br>14 ... 6 AWG|6 ... 16 mm²<br>10 ... 6 AWG|11 mm<br>0.43 in|3 mm<br>0.12 in|2 ... 3 Nm<br>18 ... 26.5 lb.in|
||Ø 6.4 mm<br>Ø 0.25 in|2.5 ... 16 mm²<br>14 ... 6 AWG|2.5 ... 16 mm²<br>14 ... 6 AWG|11 mm<br>0.43 in|5.5 mm<br>0.22 in|2 ... 3 Nm<br>18 ... 26.5 lb.in|
> [Allen key][Posidriv - flat screwdriver]
**==> picture [113 x 56] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.5 mm 0.22"<br>PZ2<br>e 3 mm 0.12"<br>e 5 mm 0.16"<br>[AMET<br>1 2<br>**----- End of picture text -----**<br>
## Accessories
|Accessories|||||||
|---|---|---|---|---|---|---|
|Description|Color|Type|Part Number||Pkg<br>qty|Weight<br>1 pce g|
|1<br>End stops<br>10 mm<br>0.394 in<br>5.2 mm<br>0.205 in<br>10 mm<br>0.394 in|Dark grey<br>~~o~~|BAM4|1SNK900001R0000||50|14.00|
|||BAZ1|1SNK900002R0000||50|5.30|
|||BAZH1<br>~~o~~<br>~~,~~|1SNK900102R0000<br>~~o~~<br>~~,~~|~~o~~<br>~~,~~<br>~~_~~|20<br>~~o~~<br>~~,~~<br>~~_~~|24.00<br>~~o~~<br>~~,~~<br>~~_~~|
|2<br>Terminal block<br>markers<br>Blank marker<br>Blank card<br>Pre-printed marker card<br>(L1-L2-L3-N-PE)|White<br>~~o~~|MG-CPM 13 41790 <br>~~o~~<br>~~,~~|1SNB041790R0512<br>~~o~~<br>~~,~~|~~o~~<br>~~,~~<br>~~_~~|1960<br>~~o~~<br>~~,~~<br>~~_~~|0.236<br>~~o~~<br>~~,~~<br>~~_~~|
||Green<br>~~o~~|MC512PA-GN<br>~~o~~<br>~~,~~|1SNK149997R0000<br>~~o~~<br>~~,~~|~~o~~<br>~~,~~<br>~~_~~|20<br>~~o~~<br>~~,~~<br>~~_~~|10.00<br>~~o~~<br>~~,~~<br>~~_~~|
||Blue|MC512PA-BL|1SNK149998R0000||20|10.00|
||White<br>~~O~~|MC512PA<br>~~O~~<br>~~:~~|1SNK149999R0000<br>~~O~~<br>~~:~~|~~O~~<br>~~=~~|20<br>~~O~~<br>~~=~~|10.00<br>~~O~~<br>~~=~~|
|||MC512PA<br>~~O~~<br>~~:~~|1SNK149002R0000<br>~~O~~<br>~~:~~|~~O~~<br>~~=~~|1<br>~~O~~<br>~~=~~|10.00<br>~~O~~<br>~~=~~|
Complete list of accessories is indicated in the terminal block datasheet including end stops. Some accessories such as jumper bars may modify the terminal block's ratings: Complete information available in the accessories section of the catalog.
PAGE 13
**DBL250 power distribution blocks** Single pole - 46 mm 1.81 in spacing
## Description
- 3 configurations: distribute unipolar and multipolar power lines, or combine several inputs
- Mount it on Din rail or plate and save up to 50% rail space compared to conventional copper bars
- Reduce the assembly time by 80% by avoiding to use fastening and isolating components
- Easy identification with the reversible cover and delivered pre-printed markers L1, L2, L3, N, PE, +, –.
## Ordering details
**==> picture [4 x 36] intentionally omitted <==**
**----- Start of picture text -----**<br>
1SNC166030V0014<br>**----- End of picture text -----**<br>
**==> picture [23 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
DBL250<br>**----- End of picture text -----**<br>
**==> picture [117 x 161] intentionally omitted <==**
**----- Start of picture text -----**<br>
3)<br>ue<br>37.2 1.46"<br>96 3.78"<br>ht 84.5 3.33"<br>| 5)<br>5.4 x 7.6 mm<br>0.21 x 0.3"<br> 1.37" 1.07"<br>34.8 27.3<br> 2.42"<br> 2.36" 2.72"<br>25.8 1.02" 60 69 61.5<br> 1.81" 29.5 1.16"<br>46<br>**----- End of picture text -----**<br>
**==> picture [61 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
46 mm 1.81 in spacing<br>**----- End of picture text -----**<br>
## Mounting instructions
**==> picture [30 x 126] intentionally omitted <==**
**----- Start of picture text -----**<br>
6 mm 0.24"<br>4 mm 0.16"<br>3 mm 0.12"<br>**----- End of picture text -----**<br>
**==> picture [63 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2<br>**----- End of picture text -----**<br>
|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|
|---|---|---|---|---|---|---|---|---|
|Description<br>Color<br>Type<br>Part Number<br>Pkg<br>Weight<br>qty<br>1 pce g<br>Feed-through<br>Single pole distribution, 12<br>connections<br>Grey<br>DBL250<br>1SNL325010R0000<br>1<br>439<br>~~nn~~<br>~~Dn~~|||||||||
||Main technical data||||||||
||Connectingcapacity|||IEC|UL||||
||Max current / Cross section|Copper<br>Aluminium||250 A / 120 mm²<br>200 A / 120 mm²|255 A / 250 Kcmil||||
||Rated voltage|||1000 V AC / 1500 V DC|1000 V||||
||Rated impulse voltage|||8 kV|||||
||Short-time withstand current(Icw 1s)<br>Short Circuit Current Rating (SCCR)<br>Ratedpeak withstand current(Ipk)<br>Protection|||11400 A<br>51 kA<br>IP10|100 kA<br>NEMA 1||||
|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|Rated impulse voltage<br>8 kV<br>Short-time withstand current(Icw 1s)<br>11400 A<br>Short Circuit Current Rating (SCCR)<br>100 kA<br>Ratedpeak withstand current(Ipk)<br>51 kA<br>Protection<br>IP10<br>NEMA 1|||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA<br>standards (Copper conductors). All other data are provided as supplementary information only. For more details, please consult our CB, UL or CSA<br>certificates and technical datasheet available on http://www.TE.com|||||||||||||||||||The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA<br>standards (Copper conductors). All other data are provided as supplementary information only. For more details, please consult our CB, UL or CSA||The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA|||The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA|
||||||||||||||||||||||||||
|CE<br>CB<br>RoHS<br>USR<br>CSA|||||EAC||||||||||BV||||||||||
|Mounting& wiringinstructions<br>Rail<br>TH 35-7.5,<br>TH 35-15<br>~~a~~|||||||||||||||||||||||||
|Connection<br>Wire type<br>Number<br>Size<br>**Input**<br>1 x<br>Ø 15.3 mm<br>35 ... 95 mm²<br>Ø 0.60 in<br>2 ... 3/0 AWG<br>|<br>~~y~~||||||35 ... 120 mm²<br>2 ... 250 Kcmil<br>~~=~~|||||||Wire stripping length<br>Tool<br>28 mm<br>6 mm<br>1.10 in<br>0.24 in<br>,<br>4<br>~~o~~||||Torque<br>19 ... 21 Nm<br>168 ... 185 lb.in<br>©<br>~~|~~||||||||
|**Output**<br>2 x<br>Ø 8.7 mm<br>2.5 ... 25 mm²<br>Ø 0.34 in<br>14 ... 4 AWG<br>5 x<br>Ø 6.4 mm<br>2.5 ... 16 mm²<br>Ø 0.25 in<br>14 ... 6 AWG<br>4 x<br>Ø 5.7 mm<br>2.5 ... 10 mm²<br>Ø 0.22 in<br>14 ... 8 AWG<br>~~L)~~|||||||||2.5 ... 35 mm²<br>14 ... 2 AWG<br>2.5 ... 16 mm²<br>14 ... 6 AWG<br>2.5 ... 10 mm²<br>14 ... 8 AWG|||||11 mm<br>0.43 in<br>11 mm<br>0.43 in<br>11 mm<br>0.43 in||4 mm<br>0.16 in<br>3 mm<br>0.12 in<br>3 mm<br>0.12 in<br>~~eo.~~||||3.5 ... 5 Nm<br>31 ... 44 lb.in<br>2 ... 3 Nm<br>18 ... 26.5 lb.in<br>2 ... 3 Nm<br>18 ... 26.5 lb.in||||||
|When using maximum cable size with insulated ferrules, use a maximum of 2 non-adjacent holes in each row.<br>**Not allowed**<br>Flexible without ferrule<br>(IEC V-K, UL class G…K)<br>Flexible with ferrule<br>(IEC V-K, UL class G…K)<br>Solid<br>(IEC V-U class 1, UL solid)<br>Rigid stranded<br>(IEC V-R class 2, UL class B/C)<br>~~a~~|||||||||||||||||||||||||
|Allen key<br> Posidriv - flat screwdriver<br>@<br>®|||||||||||||||||||||||||
|Accessories|||||||||||||||||||||||||
|Description|||||||||Color||||Type||Part Number|||||Pkg|.||Weight||
|||||||||||||||||||||qty|||1 pce|1 pce g|
|1<br>End stops<br>10 mm<br>0.394 in|||||||||Dark grey||||BAM4||1SNK900001R0000|||||50||||14.00|
|5.2 mm<br>0.205 in|||||||||||||BAZ1||1SNK900002R0000|||||50||||5.30|
|10 mm<br>0.394 in|||||||||||||BAZH1||1SNK900102R0000|||||20||||24.00|
|2<br>Terminal block<br>Blank marker|||||||||White||||MG-CPM 13 41790||1SNB041790R0512|||||1960||||0.236|
|markers<br>Blank card|||||||||Green||||MC512PA-GN||1SNK149997R0000|||||20||||10.00|
|Pre-printed marker card<br>(L1-L2-L3-N-PE)||||Pre-printed marker card|||||Blue<br>White<br>~~a~~||||MC512PA-BL<br>MC512PA<br>MC512PA||1SNK149998R0000<br>1SNK149999R0000<br>1SNK149002R0000||||20<br>20<br>1<br>~~—_~~|||||10.00<br>10.00<br>10.00|
Complete list of accessories is indicated in the terminal block datasheet including end stops. Some accessories such as jumper bars may modify the terminal block's ratings: Complete information available in the accessories section of the catalog.
INDUSTRIAL /// ENTRELEC - DBL POWER DISTRIBUTION BLOCKS
**DBL250-F power distribution blocks** Single pole - Flat entry - 29 mm 1.14 in spacing
## Description
- Suitable for distributing power from flat conductors: flexible or solid bars
- Mount it on Din rail or plate and save up to 50% rail space compared to conventional copper bars
- Reduce the assembly time by 80% by avoiding to use fastening and isolating components
- Easy identification with the reversible cover and delivered pre-printed markers L1, L2, L3, N, PE, +, –.
## Ordering details
**==> picture [4 x 36] intentionally omitted <==**
**----- Start of picture text -----**<br>
1SNC166052V0014<br>**----- End of picture text -----**<br>
**==> picture [29 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
DBL250-F<br>**----- End of picture text -----**<br>
**==> picture [119 x 172] intentionally omitted <==**
**----- Start of picture text -----**<br>
a)<br>—— 36.3 1.43"<br>75 2.95"<br>62 2.44" 5 0.2"<br>—Eoee<br>a<br>a<br>9.5 x 5.5 mm 12 x 5.5 mm<br>0.37 x 0.22" 0.47 x 0.22"<br>29 mm 1.14 in spacing<br> 1.15" 0.85"<br>29.2 21.7 2" 2.35" 2.06"<br>50.7 59.8 52.3<br>20.2 0.79"<br>15.1 0.59" 11.1 0.44"<br> 1.14"<br>29<br>**----- End of picture text -----**<br>
## Mounting instructions
**==> picture [32 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
5 mm 0.2"<br>)<br>|—<br>5.5 mm 0.22"<br>PZ2<br>**----- End of picture text -----**<br>
**==> picture [380 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Description|Color|Type|Part Number|Pkg|Weight|
|qty|1 pce|g|
|Feed-through|Single pole distribution - Flat entry, 7|Grey|DBL250-F|1SNL325060R0000|1|119|
|connections|
|Main technical data|
|Connecting capacity|IEC|UL|
|Max current / Cross section|Flexible busbar|250 A / 6 x 15.5 x 0.8 mm|250 A / 6 x 15.5 x 0.8 mm|
|Rigid busbar|208 A / 12 x 4 mm|160 A / 12 x 4 mm|
|Rated voltage|1000 V AC / 1500 V DC|1000 V|
|Rated impulse voltage|8 kV|
|Short-time withstand current (Icw 1s)|11400 A|
|Short Circuit Current Rating|(SCCR)|Please consult us|
|Rated peak withstand current (Ipk)|22.8 kA|
|Protection|IP20|NEMA 1|
**----- End of picture text -----**<br>
The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA standards (Copper conductors). All other data are provided as supplementary information only. For more details, please consult our CB, UL or CSA
certificates and technical datasheet available on http://www.TE.com
CE RoHS USR CSA EAC ~~ee~~
## Mounting & wiring instructions
**==> picture [372 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|TH 35-7.5,|
|Rail|
|Ls|TH 35-15|
|Connection|Wire type|Wire stripping length|Tool|Torque|
|Number|Size|
|||=|=|f=|@|
|Input|
|15.5 x 7.5 mm|12 x 4 mm|3 x 9 x 0.8 mm ...|15 mm|5 mm|13.5 Nm|
|1|x|
|y|0.59 x 0.28 in|||... 6 x 15.5 x 0.8 mm|0.59 in|o|0.20 in|120 lb.in|
|Output|6|x|Ø|6.6 mm|2.5 ... 16 mm²|2.5 ... 16 mm²|11 mm|5.5 mm|2 ... 3 Nm|
|Ø|0.26 in|14 ... 6 AWG|14 ... 6 AWG|0.43 in|0.22 in|18 ... 26.5 lb.in|
**----- End of picture text -----**<br>
When using maximum cable size with insulated ferrules, use a maximum of 2 non-adjacent holes in each row.
**==> picture [375 x 37] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|Not allowed|Flexible with ferrule|Solid|Rigid stranded|Solid busbar|Flexible busbar|
|Flexible without ferrule|(IEC V-K, UL class G…K)|(IEC V-U class 1, UL solid)|(IEC V-R class 2, UL class B/C)|
|(IEC V-K, UL class G…K)|
|©|[Allen key]|@|[Posidriv - flat screwdriver]|
**----- End of picture text -----**<br>
## Accessories
**==> picture [63 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2<br>**----- End of picture text -----**<br>
**==> picture [380 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Description|Color|Type|Part Number|Pkg|Weight|
|qty|1 pce|g|
|1|End stops|10 mm|0.394 in|Dark grey|BAM4|1SNK900001R0000|50|14.00|
|5.2 mm|0.205 in|BAZ1|1SNK900002R0000|50|5.30|
|10 mm|0.394 in|BAZH1|1SNK900102R0000|20|24.00|
|2|Terminal block|Blank marker|White|MG-CPM 13 41790|1SNB041790R0512|1960|0.236|
|markers|Blank card|Green|MC512PA-GN|1SNK149997R0000|20|10.00|
|:|Blue|Oo|MC512PA-BL|1SNK149998R0000|—_|20|10.00|
|White|MC512PA|1SNK149999R0000|20|10.00|
|Pre-printed marker card|MC512PA|1SNK149002R0000|1|10.00|
|(L1-L2-L3-N-PE)|
**----- End of picture text -----**<br>
Complete list of accessories is indicated in the terminal block datasheet including end stops. Some accessories such as jumper bars may modify the terminal block's ratings: Complete information available in the accessories section of the catalog.
PAGE 15
**DBL400 power distribution blocks** Single pole - 46 mm 1.81 in spacing
## Description
- 3 configurations: distribute unipolar and multipolar power lines, or combine several inputs
- Mount it on Din rail or plate and save up to 50% rail space compared to conventional copper bars
- Reduce the assembly time by 80% by avoiding to use fastening and isolating components
- Easy identification with the reversible cover and delivered pre-printed markers L1, L2, L3, N, PE, +, –.
## Ordering details
**==> picture [4 x 36] intentionally omitted <==**
**----- Start of picture text -----**<br>
1SNC166031V0014<br>**----- End of picture text -----**<br>
|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|Ordering detailsg detailsdetails|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Description<br>Color<br>Type<br>Part Number<br>Pkg<br>Weight<br>qty<br>1 pce g<br>Feed-through<br>Single pole distribution, 12<br>connections<br>Grey<br>DBL400<br>1SNL340010R0000<br>1<br>425<br>~~TE~~<br>~~TE~~<br>~~SSS~~|||||||||||||
||Main technical data||||||||||||
||Connectingcapacity|||IEC|||||UL||||
||Max current / Cross section|Copper<br>Aluminium||400 A / 185 mm²<br>300 A / 185 mm²|||||335 A / 400 Kcmil||||
||Rated voltage|||1000 V AC / 1500 V DC|||||1000 V||||
||Rated impulse voltage|||8 kV|||||||||
||Short-time withstand current(Icw 1s)<br>Short Circuit Current Rating (SCCR)<br>Ratedpeak withstand current(Ipk)<br>Protection|||18000 A<br>51 kA<br>IP10|||||100 kA<br>NEMA 1||||
**==> picture [23 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
DBL400<br>**----- End of picture text -----**<br>
**==> picture [510 x 161] intentionally omitted <==**
**----- Start of picture text -----**<br>
Short-time withstand current (Icw 1s) 18000 A<br>Short Circuit Current Rating (SCCR) 100 kA<br>Rated peak withstand current (Ipk) 51 kA<br>Protection IP10 NEMA 1<br>The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA<br>3) standards (Copper conductors). All other data are provided as supplementary information only. For more details, please consult our CB, UL or CSA<br>certificates and technical datasheet available on http://www.TE.com<br>&<br>37.2 1.46" CE CB RoHS USR CSA EAC BV<br>96 3.78" Mounting & wiring instructions<br>84.5 3.33"<br>TH 35-7.5,<br>tt EE Rail<br>TH 35-15<br>Connection Wire type Wire stripping length Tool Torque<br>Number Size<br>| A) , =e x : 6<br>5.4 x 7.6 mm<br>0.21 x 0.3" Input<br> 1.37" 1.07"<br>34.8 27.3<br> 2.42"<br> 2.36" 2.72"<br>25.8 1.02" 60 69 61.5<br> 1.81" 29.5 1.16"<br>46<br>**----- End of picture text -----**<br>
|Connection<br>Number<br>Size|Connection<br>Number<br>Size|Wire type<br>,<br>=e<br>~~x~~|Wire type<br>,<br>=e<br>~~x~~|Wire stripping length<br>~~x~~<br>:|Tool<br>6|Torque<br>6|
|---|---|---|---|---|---|---|
|**Input**<br>1 x<br>Ø 18.8 mm<br>Ø 0.74 in<br>~~y~~|Ø 18.8 mm<br>Ø 0.74 in|95 ... 150 mm²<br>3/0 ... 300 Kcmil|95 ... 185 mm²<br>3/0 ... 400 Kcmil|28 mm<br>1.10 in<br>~~o~~|8 mm<br>0.31 in<br>~~o~~<br>~~|~~|25 Nm<br>221 lb.in<br>~~|~~|
|~~y~~|||||||
|**Output**<br>2 x<br>Ø 8.7 mm<br>Ø 0.34 in<br>5 x<br>Ø 6.4 mm<br>Ø 0.25 in<br>4 x<br>Ø 5.7 mm<br>Ø 0.22 in<br>~~y~~<br>~~y~~|Ø 8.7 mm<br>Ø 0.34 in|2.5 ... 25 mm²<br>14 ... 4 AWG|2.5 ... 35 mm²<br>14 ... 2 AWG|11 mm<br>0.43 in<br>~~o~~|4 mm<br>0.16 in<br>~~o~~<br>~~|~~|3.5 ... 5 Nm<br>31 ... 44 lb.in<br>~~|~~|
||Ø 6.4 mm<br>Ø 0.25 in|2.5 ... 16 mm²<br>14 ... 6 AWG<br>||2.5 ... 16 mm²<br>14 ... 6 AWG<br>||11 mm<br>0.43 in<br>|<br>~~Om”~~|3 mm<br>0.12 in<br>~~Om”~~|2 ... 3 Nm<br>18 ... 26.5 lb.in|
||Ø 5.7 mm<br>Ø 0.22 in|2.5 ... 10 mm²<br>14 ... 8 AWG<br>||2.5 ... 10 mm²<br>14 ... 8 AWG<br>||11 mm<br>0.43 in<br>|<br>~~Om”~~|3 mm<br>0.12 in<br>~~Om”~~|2 ... 3 Nm<br>18 ... 26.5 lb.in|
**==> picture [61 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
46 mm 1.81 in spacing<br>**----- End of picture text -----**<br>
## Mounting instructions
**==> picture [28 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
8 mm 0.31"<br>4 mm 0.16"<br>3 mm 0.12"<br>**----- End of picture text -----**<br>
## Accessories
**==> picture [63 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2<br>**----- End of picture text -----**<br>
|Accessories|||||||
|---|---|---|---|---|---|---|
|Description|Color|Type|Part Number||Pkg<br>qty|Weight<br>1 pce g|
|1<br>End stops<br>10 mm<br>0.394 in<br>5.2 mm<br>0.205 in<br>10 mm<br>0.394 in|Dark grey|BAM4|1SNK900001R0000||50|14.00|
|||BAZ1|1SNK900002R0000||50|5.30|
|||BAZH1|1SNK900102R0000||20|24.00|
|2<br>Terminal block<br>markers<br>Blank marker<br>Blank card<br>Pre-printed marker card<br>(L1-L2-L3-N-PE)|White|MG-CPM 13 41790|1SNB041790R0512||1960|0.236|
||Green|MC512PA-GN|1SNK149997R0000||20|10.00|
||Blue|MC512PA-BL|1SNK149998R0000||20|10.00|
||White|MC512PA|1SNK149999R0000||20|10.00|
|||MC512PA|1SNK149002R0000||1|10.00|
Complete list of accessories is indicated in the terminal block datasheet including end stops. Some accessories such as jumper bars may modify the terminal block's ratings: Complete information available in the accessories section of the catalog.
INDUSTRIAL /// ENTRELEC - DBL POWER DISTRIBUTION BLOCKS
**DBL400-PV power distribution blocks** Single pole - 46 mm 1.81 in spacing
## Description
- Suitable for solar application with the possibility to combine 12 photovoltaic strings
- Mount it on Din rail or plate and save up to 50% rail space compared to conventional copper bars
- Reduce the assembly time by 80% by avoiding to use fastening and isolating components
- Increase the number of outputs by using the optional input and connecting two DBL together
- Easy identification with the reversible cover and delivered pre-printed markers L1, L2, L3, N, PE, +, –.
**==> picture [4 x 36] intentionally omitted <==**
**----- Start of picture text -----**<br>
1SNC166053V0014<br>**----- End of picture text -----**<br>
## Ordering details
**==> picture [380 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Description|Color|Type|Part Number|Pkg|Weight|
|qty|1 pce|g|
|Feed-through|Single pole distribution, 14|Grey|DBL400-PV|1SNL340011R0000|1|202|
|connections|
|Main technical data|
|Connecting capacity|IEC|UL|
|Max current / Cross section|Copper|550 A / (2x) 95 mm²|400 A / (2x) 250 Kcmil|
|Rated voltage|1000 V AC / 1500 V DC|1000 V|
|Rated impulse voltagepulse voltageulse voltagegee|8 kV|
|Short-time withstand current (Icw 1s)(Icw 1s)Icw 1s))|22800 A|
|Short Circuit Current Ratingg|(SCCR)SCCR))|Please consult us|
|Rated peak withstand current (Ipk)peak withstand current (Ipk)eak withstand current (Ipk)(Ipk)Ipk)pk)k))|47.88 kA|
|Protection|IP10|NEMA 1|
|The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA|
|standards (Copper conductors). All other data are provided as supplementary information only. For more details, please consult our CB, UL or CSA|
|certificates and technical datasheet available on http://www.TE.com|C€|BE|RoHS|DW|G|fil|
|CE|CB|RoHS|USR|CSA|EAC|
**----- End of picture text -----**<br>
**==> picture [33 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
DBL400-PV<br>**----- End of picture text -----**<br>
**==> picture [510 x 281] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Rated impulse voltagepulse voltageulse voltagegee|8 kV|
|Short-time withstand current (Icw 1s)(Icw 1s)Icw 1s))|22800 A|
|Short Circuit Current Ratingg|(SCCR)SCCR))|Please consult us|
|Rated peak withstand current (Ipk)peak withstand current (Ipk)eak withstand current (Ipk)(Ipk)Ipk)pk)k))|47.88 kA|
|Protection|IP10|NEMA 1|
|aa|re|The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA|
|Us|standards (Copper conductors). All other data are provided as supplementary information only. For more details, please consult our CB, UL or CSA|
|us|sy|certificates and technical datasheet available on http://www.TE.com|
|44.18|1.74"|
|—|C€|BE|RoHS|DW|G|fil|
|103|4.06"|CE|CB|RoHS|USR|CSA|EAC|
|a|92.8|3.65"|“||Mounting & wiring instructions|
|C|rea:|_|TH 35-7.5,|
|Rail|
|TH 35-15|
|a|——|Connection|Wire type|Wire stripping length|Tool|Torque|
|Number|Size|
|Ø 5.4 x 7.6 mm|
|0.21" x 0.3"|
|46 mm 1.81 in spacing|Input|
|Ø 15,5 mm|25 ... 95 mm²|25 ... 120 mm²|28 mm|6 mm|19 ... 21 Nm|
|2|x|
|Mounting instructions|Ø 0.59 in|4 … 3/0 AWG|4 ... 250 Kcmil|1.1 in|0.24 in|168 … 185 lb.in|
|Output|12|x|Ø 6.6 mm|2.5 ... 16 mm²|2.5 ... 16 mm²|11 mm|3 mm|2 ... 3 Nm|
|6 mm 0.24"|Ø 0.26 in|14 ... 6 AWG|14 ... 6 AWG|0.43 in|0.19 in|18 ... 26.5 lb.in|
|a|Ve|Not allowed|@|Jar|Flexible with ferrule|==|Solid|Rigid stranded|
|Flexible without ferrule|(IEC V-K, UL class G…K)|(IEC V-U class 1, UL solid)|(IEC V-R class 2, UL class B/C)|
|(IEC V-K, UL class G…K)|
|Ice|
|=|pos|
|||.|[Allen key]|[Posidriv - flat screwdriver]|
**----- End of picture text -----**<br>
**==> picture [61 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
46 mm 1.81 in spacing<br>**----- End of picture text -----**<br>
## Mounting instructions
3 mm 0.12"
## Accessories
**==> picture [63 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2<br>**----- End of picture text -----**<br>
**==> picture [380 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Description|Color|Type|Part Number|Pkg|Weight|
|qty|1 pce|g|
|1|End stops|10 mm|0.394 in|Dark grey|BAM4|1SNK900001R0000|50|14.00|
|5.2 mm|0.205 in|BAZ1|1SNK900002R0000|50|5.30|
|10 mm|0.394 in|BAZH1|1SNK900102R0000|20|24.00|
|2|Terminal block|Blank marker|White|MG-CPM 13 41790|1SNB041790R0512|1960|0.236|
|markers|Blank card|Green|MC512PA-GN|1SNK149997R0000|20|10.00|
|:|Blue|a|MC512PA-BL|:|1SNK149998R0000|—_|20|10.00|
|White|MC512PA|1SNK149999R0000|20|10.00|
|Pre-printed marker card|MC512PA|1SNK149002R0000|1|10.00|
|(L1-L2-L3-N-PE)|
**----- End of picture text -----**<br>
Complete list of accessories is indicated in the terminal block datasheet including end stops. Some accessories such as jumper bars may modify the terminal block's ratings: Complete information available in the accessories section of the catalog.
PAGE 17
**DBL500-22 Power Distribution Blocks** Single pole - 46 mm 1.81 in spacing
## Description
- Suitable for distributing or connecting main power lines with 2 inputs and 2 outputs
- Mount it on Din rail or plate and save up to 50% rail space compared to conventional copper bars
- Reduce the assembly time by 80% by avoiding to use fastening and isolating components
- Increase the number of outputs by using the second input and connecting two DBL together
- Easy identification with the reversible cover and delivered pre-printed markers L1, L2, L3, N, PE, +, –.
**==> picture [4 x 36] intentionally omitted <==**
**----- Start of picture text -----**<br>
1SNC166054V0014<br>**----- End of picture text -----**<br>
**==> picture [380 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Ordering details|
|Description|Color|Type|Part Number|Pkg|Weight|
|qty|1 pce|g|
|Feed-through|Single pole distribution, 4|Grey|DBL500-22|1SNL850001R0000|1|224|
|connections|
|Main technical data|
|Connecting capacity|IEC|UL|
|Max current / Cross section|Copper|500 A / (2x) 95 mm²|510 A / (2x) 250 Kcmil|
|Rated voltage|1000 V AC / 1500 V DC|1000 V|
|Rated impulse voltagepulse voltageulse voltagegee|8 kV|
|Short-time withstand current (Icw 1s)(Icw 1s)Icw 1s))|22800 A|
|Short Circuit Current Ratingg|(SCCR)SCCR))|Please consult us|
|Rated peak withstand current (Ipk)peak withstand current (Ipk)eak withstand current (Ipk)(Ipk)Ipk)pk)k))|47.88 kA|
|Protection|IP10|NEMA 1|
**----- End of picture text -----**<br>
**==> picture [32 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
DBL500-22<br>**----- End of picture text -----**<br>
**==> picture [511 x 190] intentionally omitted <==**
**----- Start of picture text -----**<br>
Rated impulse voltagepulse voltageulse voltagegee 8 kV<br>Short-time withstand current (Icw 1s)(Icw 1s)Icw 1s)) 22800 A<br>Short Circuit Current Ratingg (SCCR)SCCR)) Please consult us<br>Rated peak withstand current (Ipk)peak withstand current (Ipk)eak withstand current (Ipk)(Ipk)Ipk)pk)k)) 47.88 kA<br>Protection IP10 NEMA 1<br>J] The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA<br>7, [Ie] standards (Copper conductors). All other data are provided as supplementary information only. For more details, please consult our CB, UL or CSA<br>— TT eee certificates and technical datasheet available on http://www.TE.com<br>44.2 1.74" C€ BE Roos W EG Ei<br>103 4.06" CE CB RoHS USR CSA EAC<br>92.8 3.65" Mounting & wiring instructions<br>| a<br>TH 35-7.5,<br>Rail<br>TH 35-15<br>{ 0 0 | ou<br>Connection Wire type Wire stripping length Tool Torque<br>Number Size<br>Ø 5.4 x 7.6 mm<br>0.21" x 0.3"<br>46 mm 1.81 in spacing Input<br>Ø 15.5 mm 25 ... 95 mm² 25 ... 120 mm² 28 mm 6 mm 19 ... 21 Nm<br>2 x<br>Mounting instructions Ø 0.61 in 4 ... 3/0 AWG 4 ... 250 Kcmil 1.1 in 0.24 in 168 ... 185 lb.in<br> 1.41" 1.11"<br>35.8 28.3<br> 2.36" 2.71" 2.42"<br>26.8 1.06" 60 69 61.5<br> 1.81"<br>46 18.8 0.74"<br>**----- End of picture text -----**<br>
**==> picture [373 x 171] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|TH 35-7.5,|
|Rail|
|TH 35-15|
|ou|
|Connection|Wire type|Wire stripping length|Tool|Torque|
|Number|Size|
|Input|
|Ø 15.5 mm|25 ... 95 mm²|25 ... 120 mm²|28 mm|6 mm|19 ... 21 Nm|
|2|x|
|Ø 0.61 in|4 ... 3/0 AWG|4 ... 250 Kcmil|1.1 in|0.24 in|168 ... 185 lb.in|
|Output|2|x|Ø 15.5 mm|25 ... 95 mm²|25 ... 120 mm²|28 mm|6 mm|19 ... 21 Nm|
|Ø 0.61 in|4 ... 3/0 AWG|4 ... 250 Kcmil|1.1 in|0.24 in|168 ... 185 lb.in|
|Not allowed|Flexible with ferrule|Solid|Rigid stranded|
|Flexible without ferrule|(IEC V-K, UL class G…K)|(IEC V-U class 1, UL solid)|(IEC V-R class 2, UL class B/C)|
|(IEC V-K, UL class G…K)|
|[Allen key]|[Posidriv - flat screwdriver]|
**----- End of picture text -----**<br>
**==> picture [28 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
6 mm 0.24"<br>**----- End of picture text -----**<br>
**==> picture [511 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|1|2|\|ieoecee= L|ee|AccessoriesDescription|Color|Type|Part Number|Pkg|Weight|
|qty|1 pce|g|
|1|End Stops|10 mm|0.394 in|Dark Grey|BAM4|1SNK900001R0000|50|14.00|
|5.2 mm|0.205 in|BAZ1|1SNK900002R0000|50|5.30|
|10 mm|0.394 in|BAZH1|1SNK900102R0000|20|24.00|
|2|Terminal Block|Blank marker|White|MG-CPM 13 41790|1SNB041790R0512|1960|0.236|
|Markers|Blank card|Green|MC512PA-GN|1SNK149997R0000|20|10.00|
|Blue|Go:|MC512PA-BL|1SNK149998R0000|sz|20|10.00|
|White|MC512PA|1SNK149999R0000|20|10.00|
|Pre-printed marker card|MC512PA|1SNK149002R0000|1|10.00|
|(L1-L2-L3-N-PE)|
**----- End of picture text -----**<br>
Complete list of accessories is indicated in the terminal block datasheet including end stops. Some accessories such as jumper bars may modify the terminal block's ratings: Complete information available in the accessories section of the catalog.
INDUSTRIAL /// ENTRELEC - DBL POWER DISTRIBUTION BLOCKS
Part Number/Type classification
8
## **Index**
|Part Number|Type|Page|
|---|---|---|
|1SNB|||
|1SNB041790R0512|MG-CPM 13 41790|8|
|1SNK|||
|1SNK149002R0000|MC512PA|8|
|1SNK149997R0000|MC512PA-GN|8|
|1SNK149998R0000|MC512PA-BL|8|
|1SNK149999R0000|MC512PA|8|
|1SNK900001R0000|BAM4|8|
|1SNK900002R0000|BAZ1|8|
|1SNK900102R0000|BAZH1|8|
|1SNL|||
|1SNL308010R0000|DBL80|8|
|1SNL312510R0000|DBL125|9|
|1SNL312530R0000|DBL125-3|10|
|1SNL316010R0000|DBL160|11|
|1SNL317510R0000|DBL175|12|
|1SNL317531R0000|DBL175-C-3|13|
|1SNL325010R0000|DBL250|14|
|1SNL325060R0000|DBL250-F|15|
|1SNL340010R0000|DBL400|16|
|1SNL340011R0000|DBL400-PV|17|
|1SNL850001R0000|DBL500-22|18|
|Type|Part Number|Page|
|---|---|---|
|B|||
|BAM4|1SNK900001R0000|8|
|BAZ1|1SNK900002R0000|8|
|BAZH1|1SNK900102R0000|8|
|D|||
|DBL125|1SNL312510R0000|9|
|DBL125-3|1SNL312530R0000|10|
|DBL160|1SNL316010R0000|11|
|DBL175|1SNL317510R0000|12|
|DBL175-C-3|1SNL317531R0000|13|
|DBL250|1SNL325010R0000|14|
|DBL250-F|1SNL325060R0000|15|
|DBL400|1SNL340010R0000|16|
|DBL400-PV|1SNL340011R0000|17|
|DBL500-22|1SNL850001R0000|18|
|DBL80|1SNL308010R0000|8|
|M|||
|MC512PA|1SNK149002R0000|8|
|MC512PA|1SNK149999R0000|8|
|MC512PA-BL|1SNK149998R0000|8|
|MC512PA-GN|1SNK149997R0000|8|
|MG-CPM 13 41790|1SNB041790R0512|8|
**==> picture [73 x 43] intentionally omitted <==**
PAGE 19
## LET’S CONNECT
We make it easy to connect with our experts and are ready to provide all the support you need. For additional information or product assistance, please contact your field representative or our customer service department. Additional information is also available on the website http://www.te.com/entrelec.
## TECHNICAL SUPPORT
te.com/support-center
## Asia:
+86 400-820-6015 Europe, Middle East, & Africa: +49 6251-133-0
North America: +1-888-441-9982
## **te.com**
ENTRELEC, TE Connectivity, TE Connectivity (logo) and Every Connection Counts are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners.
## **TE Connectivity**
All other logos, products and/or company names referred to herein might be trademarks of their respective owners.
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity's obligations shall only be as set forth in TE Connectivity's Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application.
3, rue Jean Perrin 69687 Chassieu cedex France
Tel: +33 472172222
www.te.com/
© 2018 TE Connectivity Ltd. family of companies All Rights Reserved.
**1-1773959-2_EN 02/19**
**==> picture [73 x 43] intentionally omitted <==**
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
Updated at April 27, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →