Image not available
Illustrative purposes only
1SNA166627R2200
Accessory, AMP ESSAILEC Series Current Transformers, Universal Plug, ESSAILEC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TE CONNECTIVITY - ENTRELEC
- Product type: Terminal Block Accessories
- SVHC: Lead (04-Feb-2026)
- For Use With: AMP ESSAILEC Series Current Transformers
- Product Range: ESSAILEC
- Accessory Type: Universal Plug
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 117.19 € |
| Current stock | 10+ |
| Lead time | 30 days |
**==> picture [172 x 43] intentionally omitted <==**
**----- Start of picture text -----**<br>
ESSAILEC®<br>TEST BLOCKS<br>**----- End of picture text -----**<br>
ENTRELEC Terminal Blocks
INDUSTRIAL /// ENTRELEC - ESSAILEC **[®]** TEST BLOCKS
ESSAILEC® test blocks allow to safely and easily perform test operations such as current and voltage measurement, monitoring, injection, repair or replacement of meters and protective relays installed in secondary circuits of current and voltage transformers or sensors.
**==> picture [73 x 43] intentionally omitted <==**
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
1 2 3 4 5 6 7 8
## **ESSAILEC® test blocks**
**==> picture [339 x 477] intentionally omitted <==**
**----- Start of picture text -----**<br>
Overview 1/ 3<br> Current and voltage sensors application 2/ 9<br>Test principles - ESSAILEC [®] RJ45 10<br>ESSAILEC [®] RJ45 sockets for current and voltage sensors 14<br>Current transformers application 3/ 15<br>Test principles - ESSAILEC [®] RJ45 16<br>ESSAILEC [®] sockets for Current Transformers 22<br>ESSAILEC [®] pre-wired plugs for Current Transformers 24<br>ESSAILEC [®] universal adaptor with Ø 4mm outputs 25<br>ESSAILEC [®] customized plugs 26<br> Voltage transformers application 4/ 29<br>Make before break 30<br>Break before make 36<br>Closed contact 42<br>Independent circuits 48<br>Pre-wired plugs 49<br>Customized plugs 51<br>Protection lids and covers 5/ 55<br> Multicircuits 6/ 56<br>Mounting instructions 7/ 57<br>Mounting instructions for coding 58<br>Outer dimensions, mounting instructions 60<br>Index 8/ 64<br>**----- End of picture text -----**<br>
**==> picture [73 x 43] intentionally omitted <==**
1-1773959-3_EN - Edition February 2019
PAGE 1
1
**==> picture [73 x 43] intentionally omitted <==**
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**ESSAILEC[®] test blocks**
1
ESSAILEC[®] test blocks allow to safely and easily perform test operations such as current and voltage measurement, monitoring, injection, repair or replacement of meters and protective relays installed in secondary circuits of current and voltage transformers or sensors.
247 **24** Continuous operation **7** Easy plug & play solution ali[[®]]
ESSAILEC[[®]] allows a simultaneous test of 1 to 4 circuits thanks to the combination of a plug and a socket. Fast test operation
Thanks to make before break principle, the current transformers short circuiting is automatically performed (no cursor or switch element to operate manually). Current testing without cutting the energy supply.
## Safety and protection
Operator's safety
IP20 protection for the socket and IP40 with the cover. Sealing option available to prevent unauthorized access. Error free systems
Coding system on plugs & sockets prevent from risks of mixing between various circuits.
Protection against reverse plug insertion. Unitary traceability Engraved on insulating body.
## Easy to install
Multiple choice of mounting
5 possibilities to install ESSAILEC[®] on front, within the panel or on a plate.
Various choice of wiring technologies ESSAILEC[®] offers several connection types: ring tongue, screw clamp, quick-connect and RJ45, to allow different wire terminations and connections up to 10 mm².
PAGE 3
**Features and benefits**
1
ESSAILEC[®] is especially designed to fit the electricity utilities requirements for safe and reliable testing. The test operations can be made without any circuit break and without opening the panel door.
ESSAILEC[®] is approved by major utilities and successfully implemented for years in worldwide electricity production, transport and distribution networks.
## ESSAILEC[®] operation principle
## Socket design
**==> picture [218 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
Make Break Closed Independent<br>before before make<br>break (Opened)<br>at Sb I a<br>**----- End of picture text -----**<br>
ESSAILEC[®] is based on a plug & play operation solution. It is composed of a socket and a test plug.
The socket is installed in the circuit and wired to the device to be tested during its installation or servicing (protection relay in switchboard or meters).
The plug is connected to the test set and allows measurement or signal injection.
The sockets are available in the following designs:
- Socket with "Make before break" contact design, available in the current, voltage, and RJ45 ranges
- Socket with "Break before make" (opened) contact design, available in voltage application
- Socket with "Closed" contact design, available in voltage application
- Socket with "4 independent circuits" for voltage application.
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
1
## Safety & protection
Color coding
Prevent from risks of mixing between various circuits. Color coding: green for current applications, grey / orange / blue for voltage applications.
IP20 IP40
**==> picture [13 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
Seal<br>**----- End of picture text -----**<br>
## Operator’s safety
Front protection IP20 for the socket and IP40 with the protective lid. The protective lid is equipped with a sealing option to prevent unauthorized access.
Locking mechanism
Secure the plug on the socket. No risk of unplugging during test operations.
Error free systems thanks to coding pins Up to 6 possible combinations to allocate test plug with its appropriate socket for circuit differentiation.
Unitary traceability
The socket integrates a permanent tracking number engraved on insulating body.
Protection against reverse plug insertion Socket and plug integrate a special plastic shape preventing the circuit polarities reversal.
PAGE 5
**Features and benefits**
1
## Easy to install
Multiple choices of socket mounting
## Mounting on panel: front or base mounting
Mounting within the panel.
Flush mounting Half-base mounting Base mounting
**==> picture [165 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
TH35 rail mounting Rack mounting<br>**----- End of picture text -----**<br>
Various choices of wiring technologies
ESSAILEC[®] offers several connection types (according to the mounting selected): ring tongue, screw clamp, quick-connect and RJ45, to allow different wire terminations and connections up to 10 mm².
Refer to sockets panorama page for more details.
**==> picture [185 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ring tongue Quick-connect<br>**----- End of picture text -----**<br>
**==> picture [157 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Screw clamp RJ45<br>**----- End of picture text -----**<br>
Easy circuit identification »© fe
01, 02, 03, 04: equipment side.
Premarked block in two directions to allow convenient reading whatever the mounting sense.
1, 2, 3, 4: transformers side.
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
1
## Plug
The plug is connected to the test equipment by means of test plugs. Plugs are supplied in various configurations, either prewired or ready to be customized.
**==> picture [41 x 22] intentionally omitted <==**
**----- Start of picture text -----**<br>
Universal plug<br>with Ø 4 mm<br>direct outputs<br>**----- End of picture text -----**<br>
Plug with crimping pins for customization
Pre-assembled plug
2x4 poles plugs (8 contact pins) Allow testing of 4 current or voltage circuits. Available in different colors (green, grey, orange, blue).
Pre-assembled plug
Pre-assembled plug
4 poles plugs 1 pole plugs (4 contact pins) (2 contacts pins) Allow testing of 4 voltage Allow testing of 1 current circuits. or voltage circuit. Available in different colors Available in different colors (grey, orange, blue). (red for current applications or grey for voltage applications).
Plugs for customization
Plugs for customization In order to provide more flexibility to the end-users ESSAILEC[®] plugs can be customized according to the targeted application (see customized plugs catalog page).
## Protection
Lid or Cover provide dust protection (IP40) and prevent unauthorized access thanks to their embedded sealing option.
Lid and cover with electrical continuity, are necessary compatible with opened contacts sockets (Break before make).
Thanks to their inner pins and linking bars they ensure the circuits continuity.
**==> picture [63 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lid Cover<br>**----- End of picture text -----**<br>
**==> picture [76 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lid with Cover with<br>electrical electrical<br>continuity continuity<br>**----- End of picture text -----**<br>
PAGE 7
1
## **Sockets panorama**
|Contact type|Contact type|Contact type|Mounting|Connection|For current and|For current and|For current|For current||For voltage transformers|For voltage transformers|For voltage transformers||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||voltage sensors||transformers|||Grey coding||Blue coding|Orange coding|Orange coding||
|||||||||||(standard)||(polarity)|(trip)|||
||||||ao.||os|OD||«©§|a<br>OD||e|a<br>@<br>|e|e|©||e|
||||||0000|||||folono oO<br>*o<br>am<br>oF<br>o&|||eee<br>ti)<br>mw<br>oo<br>ot||||
||||||@@e6e<br>0 a -e<br>@6@e6é6<br>0000|||||||<br>36202638<br>RAENEee<br>-@-6-@-@<br>[0000||8. 8.6.<br>JHE<br>@e@e6<br>eee8||||
||||||so”||2|DP||OD|e|ef<br>of|Ff|@O|&|
|Make before break||Make before break|Flush|Ring-tongue|–||CC-E-VA|||TC-E-VA||PC-E-VA|–|||
||||||–||CC-E-VA-6.6|||TC-E-VA-2.2||PC-E-VA-8.8|–|||
||||||–||CC-E-VA-R2-6.6|||TC-E-VA-R2-2.2||–|–|||
|||||RJ45|TC-E-RJ45-INF||–|||–||–|–|||
|||||Quick connect|–||–|||TC-E-C5A-2.2||–|–|||
||||Half-base|Ring-tongue|–||CC-D-VA|||TC-D-VA||PC-D-VA|–|||
||||Base/Half-base|Screw clamp|–||–|||TC-DS-VL||PC-DS-VL|–|||
||||Base|Screw clamp|–||CC-S-INF-VL-6.6|||TC-S-INF-VL-2.2||–|–|||
||||TH35|Screw clamp|–||CC-TH35-VL-6.6|||TC-TH35-VL||–|–|||
||||Rack|Ring-tongue|–||CC-R-VA|||–||–|–|||
||||Reverse|Ring-tongue|–||CC-I-VA-2|||–||–|–|||
|Break before make|||Flush|Ring-tongue|–||–|||TO-E-VA||PO-E-VA|DEO-E-VA|||
|Opened contact|||||–||–|||TO-E-VA-12.12||–|–|||
||||Half-base|Ring-tongue|–||–|||TO-D-VA||PO-D-VA|DEO-D-VA|||
||||Base/Half-base|Screw clamp|–||–|||TO-DS-VL||PO-DS-VL|–|||
||||Base|Screw clamp|–||–|||TO-S-INF-VL-12.12||–|–|||
||||Reverse|Ring-tongue|–||–|||TO-I-VA-2||–|–|||
|Closed contact|||Flush|Ring-tongue|–||–|||TF-E-VA||PF-E-VA|–|||
||||Half-base|Ring-tongue|–||–|||TF-D-VA||PF-D-VA|DEF-D-VA|||
||||Base/Half-base|Screw clamp|–||–|||TF-DS-VL||PF-DS-VL|–|||
|Independent circuits|||Base|Screw clamp|–||–|||TT4-S-VL-INF||–|–|||
Socket designation
**==> picture [267 x 180] intentionally omitted <==**
**----- Start of picture text -----**<br>
Circuit type Mounting Coding<br>C: Current | E: Flush 6.6: Current<br>T: Voltage im TH35: Symmetrical 2.2: Voltage<br>P: Polarity Bo rail TH35 8.8: Polarity<br>DE: Trip i DS: Half-base / Base INF: With lid or cover<br>D: Half-base Ø: Without lid or cover<br>S: Base<br>R: Rack<br>I: Reverse<br>P: Connector style<br>C C - E - VA - 6.6<br>Contacts Connection<br>C: Make before break VA: Ring-tongue<br>O: Opened VL: Screw clamp<br>F: Closed C5A: Quick-connect<br>RJ45: RJ45 wire<br>**----- End of picture text -----**<br>
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**Current and voltage sensors application** Make before break
2
**==> picture [257 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
Test principles - ESSAILEC [®] RJ45 10<br>ESSAILEC [®] RJ45 sockets for current and voltage sensors 14<br>**----- End of picture text -----**<br>
**==> picture [73 x 43] intentionally omitted <==**
PAGE 9
**Current and voltage sensors application** Make before break test principle - Measurement with ESSAILEC[®] RJ45 test plug
2
**==> picture [374 x 585] intentionally omitted <==**
**----- Start of picture text -----**<br>
RJ45 plug RJ45 socket<br>FI-RJ45-DIA4 TC-E-RJ45-INF<br>RJ45 plug<br>Le“o4- lil<br>L1 L2 L3<br>2 1 01<br>LPCT1<br>2 02<br>3 03<br>4 04<br>°<br>LPVT1<br>RJ45 socket<br>RJ45 plug<br>| = |dey<br>LPCT2 a 1 01<br>2 02<br>3 03<br>U se|<br>4 04<br>LPVT2 | = |<br>RJ45 socket<br>RJ45 plug<br>7<br>LPCT3 2 1 01<br>2 02<br>3 03<br>4 04<br>LPVT3 |= |<br>RJ45 socket<br>Test equipment<br>RJ45<br>Test equipment<br>RJ45<br>Protection relays<br>Test equipment<br>RJ45<br>**----- End of picture text -----**<br>
LPCT : Low power current transducer (current sensor) LPVT: Low power voltage transducer (voltage sensor)
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
Make before break base - Injection with ESSAILEC[®] RJ45 test plug
2
**==> picture [360 x 189] intentionally omitted <==**
**----- Start of picture text -----**<br>
RJ45 plug RJ45 socket<br>— FI-RJ45-DIA4 TC-E-RJ45-INF<br>RJ45 plug<br>L1 L2 L3 44<br>LPCT1 en 1 01<br>2 02<br>3 03<br>4 04<br>LPVT1<br>|=<br>RJ45 socket<br>Calibration equipment<br>RJ45<br>Protection relays<br>**----- End of picture text -----**<br>
LPCT : Low power current transducer (current sensor) LPVT: Low power voltage transducer (voltage sensor)
PAGE 11
**Current and voltage sensors application** Make before break test principle - With ESSAILEC[®] RJ45 test plug
2
## Applications
- Injection
- Equipment replacement
## 1. Normal service
1.1 ESSAILEC[®] RJ45 sockets have a shielded body. The 3 sockets are required to cover the testing operation on the 3 main lines (L1, L2, L3).
1.2 The lid is installed on the socket and can be sealed to prevent unauthorized access. The socket circuits are closed and signals flow from current and voltage sensors to protection relay.
## 2. Lid removal
The lid is removed.
**==> picture [41 x 40] intentionally omitted <==**
**----- Start of picture text -----**<br>
2<br>Lid<br>removed<br>**----- End of picture text -----**<br>
## 4.2 Test phase: Injection
**==> picture [39 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>Normal<br>service<br>**----- End of picture text -----**<br>
The RJ45 plug allows to perform injection. Plug a RJ45 connector on to the ESSAILEC[®] RJ45 plug to test the protection relay through the integrated RJ45 input.
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
Make before break base - Injection with ESSAILEC[®] RJ45 test plug
2
## 3. Preparation: Test plugs connections
## 3.2 The ESSAILEC[®] RJ45 test plug has
**==> picture [20 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
2<br>**----- End of picture text -----**<br>
built-in dia. 4 (1) and RJ45 test sockets (2) in order to simplify the test operations. They allow current and voltage sensors measurement (1) as well as injection to the protection relay (2).
3.1 The test equipment is equipped with dia. 4 test plugs.
## 4. Test phase: Make before Break
3 Preparation: Test plugs connections 4 Test phases Measurement yf Injection
When the plug is fully inserted in the socket, inner mobile contacts (3) are pushed down by plug’s plastic leads (4) and circuits are opened. Signals are derived into the dia. 4 plug towards the test set.
It is possible to perform simultaneously current and voltage sensors measurement.
~~7~~
## 4.1 Test phase: Measurement
Ex: Voltage sensors measurement
Ex: Voltage and current sensors measurement
PAGE 13
**Current and voltage sensors application** ESSAILEC[®] RJ45 sockets for current and voltage sensors - Make before break
2
## Description
Dedicated for the use in Digital Switchgear including sensors (current or voltage):
**==> picture [104 x 145] intentionally omitted <==**
**----- Start of picture text -----**<br>
x4<br>Cssailee 4 |<br>» [|]<br>a<br>3)<br>TC-E-RJ45<br>1SNC169160V0014<br>**----- End of picture text -----**<br>
- RJ45 connection type (Cat.5),
- Allow safe and easy measurement and injection operations,
- Signals protection against EMI/RFI thanks to shielded lid on shielded socket,
- Shielding tests according to IEC 62271-1 Annex J,
- Grounding point: M5 screw to be wired with an adapted ring lug termination.
Make before break principle:
- The circuits are automatically disconnected with the insertion of the plug,
- The circuits close automatically when the plug is removed.
Main technical data
Mounting instructions
|||Connecting capacity<br>IEC 947-1|||||||
|---|---|---|---|---|---|---|---|---|
|||Body<br>Polycarbonate UL94 V0|Tool|||Posidriv|||
|||Conductiveparts<br>Silver-plated<br>Rated voltage<br>125 V<br>~~es~~|(for grounding<br>screw)|||Ø<br>Ø||4 mm<br>0.16 in|
|||Impulse withstand voltage<br>1000 V<br>~~a~~|||||||
|||Pollution degree<br>3<br>~~a~~|||||||
|||Rated current<br>1.5 A<br>Accuracy<br>0.5 %<br>Storage temperature range<br>-40 ... +85 °C<br>~~es~~|Torque<br>(for grounding<br>screw)||6|1.2 Nm<br>10.8 lb.in|||
|||Workingtemperature range<br>-40 ... +85 °C|||||||
|||Protection without lid / with lid<br>IP20 / IP40<br>~~a~~|||||||
|||Ordering details<br>~~a~~|Compatible products|Compatible products|||||
|||Color<br>Type<br>Part Number<br>Pkg<br>Weight|Lid / Cover|Plug||||Socket|
|eo<br>ll <br>‘a.<br>SP <br>oe<br>ae||qty<br>1pceg<br>Socket<br>Flush mounting<br>Grey<br>TC-E-RJ45-INF<br>1SNA566000R0000<br>3<br>138<br>Included<br>Plug<br>Grey<br>FI-RJ45-DIA4<br>1SNA566001R0000<br>1<br>69.6<br>–<br> ~~—————~~<br> ~~a~~<br>~~TT ~~<br>~~ee~~||FI-RJ45-DIA4<br>–<br>–<br>TC-E-RJ45-INF<br> ~~OO~~|||||
|Accessories||||||||
|---|---|---|---|---|---|---|---|
|Description|Color||Type|Part Number||Pkg<br>qty|Weight<br>(1pce)<br>g|
|1<br>Protectingcovers for RJ45 sockets|Grey||CPT-RJ45|1SNA167002R0000||1|25.4|
For connection details, please refer to mounting instruction 1SNC169044L1701
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**Current transformers application** Make before break
3
**==> picture [257 x 159] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Test principles|16|
|ESSAILEC|[®]|sockets for Current Transformers|22|
|ESSAILEC|[®]|pre-wired plugs for Current Transformers|24|
|ESSAILEC|[®]|universal adaptor with Ø 4mm outputs|25|
|ESSAILEC|[®]|customized plugs|26|
**----- End of picture text -----**<br>
**==> picture [73 x 43] intentionally omitted <==**
PAGE 15
**Current transformers application** Make before break test principle
3
Measurement with 2x4 poles test plug
**==> picture [330 x 231] intentionally omitted <==**
**----- Start of picture text -----**<br>
01<br>{ 02 9<br>03<br>04<br>1<br>2<br>3<br>4 1 01<br>2 02<br>COR-C-R4-6.6 ia 3 03<br>A B C 4 04<br>S1 | 1 01<br>S2 S1 2 02<br>S2 S1 3 03<br>S2 4 04<br>Test equipment<br>Protection relays, meters, measurement, equipment<br>**----- End of picture text -----**<br>
Injection or equipment replacement with 2x4 poles test plug
**==> picture [319 x 200] intentionally omitted <==**
**----- Start of picture text -----**<br>
01 External<br>0203 Short-circuiting<br>04<br>1 01<br>2 02<br>COR-C-R4-6.6<br>fe § i 3 a 03<br>A B C 4 04<br>|<br>S1 1 01<br>S2 S1 2 02<br>S2 S1 3 03<br>S2 4 04<br>:<br>Injection equipment<br>Equipment<br>**----- End of picture text -----**<br>
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
Make before break test principle
3
## Injection or equipment replacement with 2x4 poles test plug (4 poles short-circuit)
**==> picture [367 x 297] intentionally omitted <==**
**----- Start of picture text -----**<br>
01<br>02<br>03<br>04<br>/ 4 & 2999)<br>Internal short-circuiting<br>Link (1, 2, 3, 4)<br>COR-C-R5-6.6<br>Automatic<br>CT short-circuiting<br>when plug-in<br>1 01<br>2 02<br>Pin 3 03<br>A B C 4 04<br>S1 ee 1 01<br>S2 S1 2 02<br>S2 S1 3 03<br>S2 4 04<br>; TL ry<br>Injection equipment<br>Equipment<br>**----- End of picture text -----**<br>
PAGE 17
Make before break test principle - With 2x4 poles test plug
## **Current transformers application**
## Applications
- Measurement on CT’s
- Injection
- Equipment replacement
## 1. Normal service
2. Preparation: plug and lid
1.1 ESSAILEC[®] current 1.2 The lid is installed on the 2.1 The lid is removed. 2.2 Connect the ESSAILEC[®] sockets allow the simulsocket and can be sealed to test plug leads to the test 3 taneous testing operaprevent unauthorized acset. (For equipment change ~~’~~ tions of 1 to 4 indepencess. The socket circuits or injection, short-circuit dent circuits on the are closed and signals flow externally the 4 test leads consame socket. from nected on the current transcurrent transformers former side: 1-2-3-4) to the equipment to be tested. 2
## 5. Back to normal service
**==> picture [41 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
5<br>Back to<br>normal<br>service<br>**----- End of picture text -----**<br>
5.1 Plug removal closes back the socket contacts and signals flow again through the socket.
5.2 Lid is put back in place.
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
3
## 3. Test phase: Make
## 4.1 Measurement: Test phase - Break
**==> picture [42 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
COR-C-R4-6.6<br>**----- End of picture text -----**<br>
During plug insertion, plug pins make contact with socket pins (1). Contacts remain closed and the signal flow has not change. This operation prevent signal interruption (mandatory for current transformers).
When the plug is fully inserted in the socket, inner mobile contacts (2) are pushed down by plug’s plastic leads (3) and the four circuits are opened simultaneously. Signals are derived into the plug towards the test set without interruption of continuity.
## 4.2 Injection or equipment
## replacement: Test phase - Break
**==> picture [42 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
Injection<br>Short-circuited<br>**----- End of picture text -----**<br>
**==> picture [53 x 37] intentionally omitted <==**
**----- Start of picture text -----**<br>
4<br>Test phase:<br>Break<br>**----- End of picture text -----**<br>
During preparation phase, the plug 4 test leads (1-2-3-4: current transformer side) have been short-circuited externally (4).
When the plug is fully inserted in the socket, the current transformer is automatically short-circuited and current injection (or equipment change) can be done on the equipment side (5).
PAGE 19
Make before break test principle - With 2x4 poles test plug (4 poles short-circuited)
3
## **Current transformers application**
## Applications
- Measurement on CT’s
- Injection
- Equipment replacement
## 1. Normal service
## 2. Preparation: plug and lid
1.1 ESSAILEC[®] current sockets allow the simultaneous testing operations of 1 to 4 independent circuits on the same socket.
1.2 The lid is installed on 2.1 The lid is removed.
equipment side (1-2-3-4). The socket and can be sealed to prevent unauthorized access. The socket circuits are closed and signals flow from current transformers to the equipment to be tested.
2.1 The lid is removed.
2.2 Connect the ESSAILEC[®] test plug leads to the test set. This plug is equipped with a built-in short-circuiting on equipment side (1-2-3-4).
## 5. Back to normal service
**==> picture [41 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
5<br>Back to<br>normal<br>service<br>**----- End of picture text -----**<br>
5.1 Plug removal closes back the socket contacts and signals flow again through the socket.
5.2 Lid is put back in place.
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
3
## 3. Test phase: Make & CT short-circuiting
**==> picture [42 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
COR-C-R5-6.6<br>**----- End of picture text -----**<br>
The plug is equipped with built in short circuited contacts on current transformers side (1-2-3-4)
During plug insertion, plug pins make contact with the socket pins (1), and simultaneously the current transformer is short-circuited.
4. Test phase: Break and short-circuit (injection or equipment replacement)
4 3 4 foe Test phase: Break 4.1 When the plug is fully inserted in the socket, mt. ia inner mobile contacts (3) are opened by plastic lead (4). The current transformer is automatically short-circuited and circuits are opened.
Injection 5 = ~~a~~ — ~~—~~ 4.2 Current injection can be done on the 6 equipment (5).
PAGE 21
**Current Transformers application** ESSAILEC[®] sockets for Current Transformers – Make before break
## Description
Short-circuited type contacts for measurement, calibration and distribution applications. Make before break principle:
**==> picture [98 x 138] intentionally omitted <==**
**----- Start of picture text -----**<br>
x4<br>Ss ¢ a -<br>®—— al<br>q ~ ~ @<br>CC-E-VA<br>1SNC169123V0014<br>**----- End of picture text -----**<br>
- The circuit is automatically shorted with the insertion of the plug.
- The circuit closes automatically when the plug is removed.
- This system guarantees a complete safety.
- By convention, green coding is for current circuit.
**==> picture [583 x 444] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|Main technical data|Mounting instructions|
|Connecting capacity|IEC 947-1|Rail|G32, TH 35-7.5,|
|TH 35-15|
|Screw clamp|Rigid - Solid / Stranded|0.2 ... 6 mm²|Screw clamp|
|®——|al|
|q ~ ~|@|(VL)|Flexible|0.22 ... 4 mm²|
|Ring tongue|Flexible|0.34 ... 10 mm²|Wire|9.5 mm|
|+—_L.|
|CC-E-VA|(VA)|Ø lug hole size|3 mm|stripping|0.370 in|
|Width|7.5 mm|length|
|Body|Polycarbonate|
|Conductive parts|Gold-plated|Tool|Flat screwdriver|
|Rated voltage|400 V|Ø|4 mm|
|Impulse withstand voltage|4000 V|Ø|0.157 in|
|Pollution degree|3|
|Rated current|15 A|
|Short-circuit current|100 A/5 s ... 200 A/1 s|Torque|0.5 ... 0.8 Nm|
|Storage temperature range|-25 ... +70 °C|4.4 ... 7.1 lb.in|
|Working temperature range|-10 ... +55 °C|
|Protection without lid / with lid|IP20 / IP40|
|3|a|Coding color|Green|
|’|
|Ordering details|Compatible products|
|Type|Part Number|Pkg|Weight|Lid|Cover|Universal|Pre-wired plugs|
|qty|plug|2x4 poles|4 poles|1 pole|
|1 pce|Ø 4 mm|Ø 4 mm|Ø 4 mm|Ø 4 mm|
|g|bayonet|bayonet|bayonet|
|Flush mounting|
|Ring-tongue|
|&|CC-E-VA|1SNA166737R2000|1|145|CPC-1|–|FIC-2/4-DIA4|COR-C-R4-6.6|COR-C-R5-6.6|COR-C-R3|
|CC-E-VA-6.6|1SNA166625R2000|1|150|Lid +|
|CC-E-VA-R2-6.6|1SNA166976R0000|50|170|coding|COR-C-R1-6.6|COR-C-R2-6.6|COR-C-3|
|included|
|Base / Half-base mounting|
|Screw clamp|
|CC-S-INF-VL-6.6|1SNA166722R2100|1|200|–|Cover +|FIC-2/4-DIA4|COR-C-R4-6.6|COR-C-R5-6.6|COR-C-R3|
|coding|
|COR-C-R1-6.6|COR-C-R2-6.6|COR-C-3|
|included|
|Ring-tongue|
|CC-D-VA|1SNA166738R0100|1|90|CPC-1|–|FIC-2/4-DIA4|COR-C-R4-6.6|COR-C-R5-6.6|COR-C-R3|
|COR-C-R1-6.6|COR-C-R2-6.6|COR-C-3|
|TH35 rail mounting|
|Screw clamp|
|CC-TH35-VL-6.6|1SNA166963R0000|1|114|CPC-1|included|FIC-2/4-DIA4|COR-C-R4-6.6|COR-C-R5-6.6|COR-C-R3|
|COR-C-R1-6.6|COR-C-R2-6.6|COR-C-3|
**----- End of picture text -----**<br>
Rack mounting
**==> picture [430 x 117] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|Ring-tongue|
|CC-R-VA|1SNA166523R1200|1|140|CPC-1|–|FIC-2/4-DIA4|–|–|COR-C-R3|
|–|–|COR-C-3|
|es|ee|ee|eeee|ee ee|
|.|Reverse mounting|
|Ring-tongue|
|CC-I-VA-2|1SNA166941R2500|1|210|–|–|–|–|–|COR-C-R3|
|–|–|COR-C-3|
|,|
|ri|EE|
|* compatible with CC-DS-VL socket only in "base" mounting option.|
**----- End of picture text -----**<br>
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**Current Transformers application** ESSAILEC[®] sockets for Current Transformers – Make before break
3
**==> picture [84 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2 3<br>4 6 7<br>5<br>**----- End of picture text -----**<br>
|Description<br>~~bo~~|Type<br>~~bo~~|Part Number<br>~~bo~~|~~bo~~|Pkg<br>qty<br>~~bo~~|Weight<br>1 pce<br>g<br>~~bo~~|
|---|---|---|---|---|---|
|1<br>Interlockingpeg<br>For 2 sockets assembly|CVABM|1SNA183436R0500||10|0.4|
|2<br>Mounting kits<br>For TH35 rail (a)<br>3<br>For DIN 1 rail (a)<br>4<br>For ring-tongue flush mounting(b)|KEM-3|1SNA166962R0000||10|24|
||FX|1SNA167682R2300||10|20|
||KEM-1|1SNA166928R2000||50|18|
|6<br>Lateral jumper bars Compatible with ring-tongue connection only (VA) (b)<br>7<br>Compatible with screw connection only (VL); IP20 (c)<br>~~(S(O~~|PCVA|1SNA167496R1100||10|1|
||PCVL<br>~~(S(O~~|1SNA167681R2200<br>~~(S(O~~|~~(S(O~~|10|1|
|5<br>Jumper bars<br>For two sockets screw connection type (c)<br>~~(S(O~~|BJ-VL<br>~~(S(O~~|1SNA167680R0500<br>~~(S(O~~|~~(S(O~~|10|1|
(b) compatible with ring-tongue connection type socket only (VA).
- (c) compatible with screw connection type socket only (VL).
Compatible products
**==> picture [373 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lid Cover Plug 2x4 poles bayonet Plug 4 poles bayonet Plug 1 pole bayonet<br>CPC-1 CPC-7 COR-C-R1-6.6 COR-C-R2-6.6 COR-C-3<br>**----- End of picture text -----**<br>
**==> picture [311 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
Universal plug Plug 2x4 poles Ø 4 mm Plug 4 poles Ø 4 mm Plug 1 pole Ø 4 mm<br>FIC-2/4-DIA4 COR-C-R4-6.6 COR-C-R5-6.6 COR-C-R3<br>**----- End of picture text -----**<br>
## Connection technologies
**==> picture [165 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ring-tongue Screw clamp<br>**----- End of picture text -----**<br>
PAGE 23
**Current Transformers application** ESSAILEC[®] pre-wired plugs for Current Transformers
## Description
- Standard current plugs are compatible with ESSAILEC[®] current sockets.
- Plugs are pre-wired with contact pins (BRE...) , coding, cables and test plugs assembled to ease your test operations.
## Main technical data
|operations.<br>Main technical data||
|---|---|
|Connecting capacity|IEC 947-1|
|Body|Polycarbonate|
|Conductiveparts|Gold-plated|
|Rated voltage|400 V|
|Impulse withstand voltage|4000 V|
|Pollution degree|3|
|Rated current|15 A|
|Short-circuit current|100 A/5 s ... 200 A/1 s|
|Storage temperature range|-25 ... +70 °C|
|Workingtemperature range|-10 ... +55 °C|
|||||||||Compatible||
|---|---|---|---|---|---|---|---|---|---|
|||Ordering details||||||products||
|||Description|Type|Part Number||Pkg|Weight|Socket||
|||||||qty|1pceg|||
|||Plug 2x4 poles||||||||
|||1 plug 2x4 pins / Green|COR-C-R4-6.6|1SNA167932R1500||1|1080|CC-E-VA||
|3|a|4 x Ø 4 mm test plugs / Black<br>4 x Ø 4 mm test plugs / Red<br>Conductors section: 2.5 mm²<br>cable length: 2 m / 79"<br>1 plug 2x4 pins / Green<br>4 bayonet security test plugs / Green<br>4 bayonet security test plugs / Red<br>Conductors section: 2.5 mm²<br>cable length: 2 m / 79"|COR-C-R1-6.6|1SNA166638R0500||1|1080|CC-E-VA-6.6<br>CC-E-VA-R2-6.6<br>CC-S-INF-VL-6.6<br>CC-D-VA<br>CC-TH35-VL-6.6<br>CC-E-VA<br>CC-E-VA-6.6<br>CC-E-VA-R2-6.6<br>CC-S-INF-VL-6.6<br>CC-D-VA||
|||||||||CC-TH35-VL-6.6||
|||Plug 4 poles||||||||
|||1 plug 2x4 pins with 4 short circuited pins|COR-C-R5-6.6|1SNA167934R1700||1|670|CC-E-VA||
|||(1-2-3-4) / Green||||||CC-E-VA-6.6||
|||4 x Ø 4 mm test plugs / Black||||||CC-E-VA-R2-6.6||
|||Conductors section: 2.5 mm²||||||CC-S-INF-VL-6.6||
|||cable length: 2 m / 79"||||||CC-D-VA||
|||||||||CC-TH35-VL-6.6||
|||1 plug 2x4 pins with 4 short circuited pins|COR-C-R2-6.6|1SNA166778R1100||1|670|CC-E-VA||
||=-__§|(1-2-3-4) / Green<br>1 bayonet security test plug / Green<br>1 bayonet security test plug / Grey||||||CC-E-VA-6.6<br>CC-E-VA-R2-6.6<br>CC-S-INF-VL-6.6||
|||1 bayonet security test plug / Brown||||||CC-D-VA||
|||1 bayonet security test plug / Yellow||||||CC-TH35-VL-6.6||
|||Conductors section: 2.5 mm²||||||||
|||cable length: 2 m / 79"||||||||
|||Plug 1 pole||||||||
|||1 plug 2 pins / Red|COR-C-R3|1SNA166979R0000||1|320|CC-E-VA||
||—|2 dia. 4 mm test plugs / Black||||||CC-E-VA-6.6<br>CC-E-VA-R2-6.6<br>CC-S-INF-VL-6.6||
|||||||||CC-D-VA||
|||||||||CC-TH35-VL-6.6||
|||||||||CC-R-VA||
|||||||||CC-I-VA-2||
|||1 plug 2 pins / Red|COR-C-3|1SNA166643R0200||1|320|CC-E-VA||
||—|2 bayonet security test plugs / Yellow||||||CC-E-VA-6.6<br>CC-E-VA-R2-6.6<br>CC-S-INF-VL-6.6<br>CC-D-VA||
|||||||||CC-TH35-VL-6.6||
|||||||||CC-R-VA<br>CC-I-VA-2|1SNC169017S0201|
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**Current Transformers application** ESSAILEC[®] universal adaptor with Ø 4mm outputs
3
## Description
- Universal adaptor compatible with all ESSAILEC[®] current socket
- It ensures quick and consistently reliable ESSAILEC[®] sockets tests
**==> picture [4 x 35] intentionally omitted <==**
**----- Start of picture text -----**<br>
1SNC169154V0014<br>**----- End of picture text -----**<br>
- Ø 4 mm test plugs may be inserted directly without the need for extra accessories or tools. It is compatible with all the insulated Ø 4mm test plugs available on the market
- Standard current plugs are compatible with ESSAILEC[®] current sockets.
- Plugs are pre-wired with contact pins (BRE...) , coding, cables and test plugs assembled to ease your test operations.
## Main technical data
FIC-2/4-DIA4
|operations.<br>Main technical data||
|---|---|
|Connecting capacity|IEC 947-1|
|Body|Polycarbonate|
|Conductiveparts|Gold-plated|
|Rated voltage|400 V|
|Impulse withstand voltage|4000 V|
|Pollution degree|3|
|Rated current|15 A|
|Short-circuit current|100 A/5 s ... 200 A/1 s|
|Storage temperature range|-25 ... +70 °C|
|Workingtemperature range|-10 ... +55 °C|
|Ordering details||||||Compatible products|
|---|---|---|---|---|---|---|
|Description|Type|Part Number||Pkg|Weight|Socket|
|||||qty|1pceg||
|Universal plug|||||||
|Plug 2x4 pins|FIC-2/4-DIA4|1SNA167937R0000||1|60|CC-E-VA|
|with direct insertion Ø 4 mm||||||CC-E-VA-6.6|
|||||||CC-E-VA-R2-6.6|
|||||||CC-S-INF-VL-6.6|
|||||||CC-D-VA|
|||||||CC-TH35-VL-6.6|
|||||||CC-R-VA|
**==> picture [162 x 90] intentionally omitted <==**
**----- Start of picture text -----**<br>
44 1.73" 20 0.78" 25 0.98" 10.5 0.41"<br>a<br>Ooo oo<br>OOOO<br>Dimensions (mm, inches)<br> 2.48"<br>63<br>**----- End of picture text -----**<br>
**==> picture [169 x 82] intentionally omitted <==**
**----- Start of picture text -----**<br>
ti 01 it 01 if 01 01 |<br>oe or’<br>1 1 1 1<br>Adaptor Socket Adaptor + socket<br>Electrical wiring for a socket with short-circuited contacts and an<br>universal adaptor<br>**----- End of picture text -----**<br>
For connection details, please refer to mounting instruction 1SNC169041L0201
PAGE 25
**Current Transformers application** ESSAILEC[®] customized plugs
3
## Description
Short-circuited type contacts for measurement, calibration and distribution applications. Make before break principle:
- The circuit is automatically shorted with the insertion of the plug.
- The circuit closes automatically when the plug is removed.
- This system guarantees a complete safety.
- By convention, green coding is for current circuit.
**==> picture [506 x 577] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|Ordering details|Compatible|
|Description|Type|Part Number|Pkg|Weight|products|
|qty|1 pce|g|Socket|
|1 pole plug with contact pins|
|Plug with 2x 2.5 mm² contact pins|FIC-2/1-1|1SNA166819R2300|1|27|CC-E-VA|
|(BRE-C-2.5), without coding pins.|CC-E-VA-6.6|
|CC-E-VA-R2-6.6|
|CC-S-INF-VL-6.6|
|J|CC-D-VA|
|CC-TH35-VL-6.6|
|CC-R-VA|
|CC-I-VA-2|
|Plugs without contact pins (contact pins BRE-C..., to be ordered separately)|
|Plugs 2x4 poles, long cover, with 2 coding|FIC-2/4-2|1SNA166936R1000|1|105|CC-E-VA|
|pins (COP-FI-1) and 8 locking pins.|CC-E-VA-6.6|
|Contacts pins (BRE-C...) to be ordered separately.|CC-E-VA-R2-6.6|
|CC-S-INF-VL-6.6|
|CC-D-VA|
|CC-TH35-VL-6.6|
|Plugs 2x4 poles, short cover, with 2 coding|FIC-2/4-1|1SNA166525R1400|1|91|CC-E-VA|
|pins (COP-FI-1) and 8 locking pins.|CC-E-VA-6.6|
|Contacts pins (BRE-C...) to be ordered separately.|CC-E-VA-R2-6.6|
|CC-S-INF-VL-6.6|
|CC-D-VA|
|CC-TH35-VL-6.6|
|Plug 2x4 poles, rack mounting R version, with 2|FIC-2/4-R|1SNA166529R2000|1|80|CC-R-VA|
|coding pins (COP-FI-1) and 8 locking pins.|
|Contacts pins (BRE-C...) to be ordered separately.|
|Plug 2x4 poles, reverse mounting I version, with|FIC-2/4-I|1SNA166589R2500|1|60|CC-I-VA-2|
|2 coding pins (COP-FI-1) and 8 locking pins.|
|Contacts pins (BRE-C...) to be ordered separately.|
|=|
|BRE contact pins|
|Pin 1 mm²|BRE-C-1|1SNA167264R0700|10|2.6|–|
|Pin 1.5 mm²|BRE-C-1.5|1SNA167265R0000|10|2.6|–|
|o|
|Pin 2.5 mm²|BRE-C-2.5|1SNA167260R1700|10|3|–|
|Pin 4 mm²|BRE-C-4|1SNA205876R0400|10|3|–|
|Pin 6 mm²|BRE-C-6|1SNA168146R0200|10|3|–|
|Tools for contact pins|
|1|Pin extraction tool|EXBR1|1SNA167008R0300|1|24|–|
|2|Crimping tool for BRE pins 1 to 2.5 mm² (1)|PSC|1SNA173181R1300|1|478|–|
|1|2|3|Locking sleeve for contact pin|DLVR|1SNA167971R2400|10|0.4|–|
|dia 4 mm test plugs|
|4|IP20 with mobile protection|FC4-1|1SNA167927R1000|10|11|–|
|3|a|5|IP20 with permanent protection|FC4-5|1SNA167931R1400|10|10|–|
|4|
|Bayonet plugs|
|5|@|——|6|Bayonet security test plug / Black|FCB-1|1SNA167690R0700|10|7|–|
|Bayonet security test plug / Red|FCB-2|1SNA167692R2500|10|7|–|
|6|a|
|7|Isolating cap for FCB plug|CA|1SNA167697R2200|10|1.2|–|
|Accessories|
|7|8|Straight adaptor|IR1|1SNA167622R2600|5|15|–|
|9|H adaptor (short-circuit bridge)|IR2|1SNA167623R2700|5|35|–|
|CO|8|»|
|10|Isolating cap for IR1 and IR2 adaptors|DI|1SNA167981R1700|10|7|–|
|11|Adaptor between FCB plug and ring-tongue test|IR3|1SNA167624R2000|10|6.4|–|
|9|
|interface|
|10|ET|
|Coding pins|
|12|Plug coding pin|COP-FI-1|1SNA167378R1100|10|2.3|–|
|11|
|12|re|(1) Refering to 1SNC169040D1702 to find other crimping tools|
**----- End of picture text -----**<br>
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**Current Transformers application** ESSAILEC[®] customized plugs
3
Pin installation on plugs
**==> picture [265 x 157] intentionally omitted <==**
**----- Start of picture text -----**<br>
Locking pin, DLVR supplied with<br>the plug<br>BRE pin<br>**----- End of picture text -----**<br>
**==> picture [73 x 43] intentionally omitted <==**
PAGE 27
4
**==> picture [73 x 43] intentionally omitted <==**
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**Voltage transformers application**
**==> picture [257 x 197] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Make before break|30|
|Break before make|36|
|Closed contact|42|
|Independent circuits|48|
|Pre-wired plugs|49|
|Customized plugs|51|
**----- End of picture text -----**<br>
4
**==> picture [73 x 43] intentionally omitted <==**
PAGE 29
**Voltage transformers application**
Make before break test principle
4 ;
Simultaneous measurement and injection with 2x4 poles test plug
**==> picture [372 x 547] intentionally omitted <==**
**----- Start of picture text -----**<br>
01<br>02<br>03<br>04<br>1<br>2<br>3<br>4<br>COR-T-R5-2.2 1 01<br>2 02<br>imi 3 03<br>N A L1 L2 L3 E a 4 04<br>1 01<br>ovate<br>2 02<br>3 03<br>4 04<br>| = |<br>~- 01<br>02<br>03 Not used<br>04<br>1<br>2<br>3 1 01<br>4<br>2 02<br>COR-T-R5-2.2 iad 3 03<br>N L1 L2 L3 4 04<br>1 01<br>ota ste<br>2 02<br>3 03<br>4 04<br>Test equipment Injection equipment<br>Equipment<br>Test equipment<br>Equipment<br>**----- End of picture text -----**<br>
Measurement with 2x4 poles test plug
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
Make before break test principle
4
## Injection with 2x4 poles test plug
**==> picture [371 x 200] intentionally omitted <==**
**----- Start of picture text -----**<br>
01<br>02<br>03<br>04<br>1<br>23 Not used<br>4<br>COR-T-R5-2.2 1 01<br>2 02<br>3 03<br>N L1 L2 L3 4 04<br>1 01<br>leYo_oYol<br>2 02<br>3 03<br>et ee<br>4 04<br>Injection equipment<br>Equipment<br>**----- End of picture text -----**<br>
PAGE 31
**Voltage transformers application** Make before break test principle - With 2x4 poles test plug
4
## Applications
- Measurement on VT’s
- Injection
- Equipment replacement
## 1. Normal service
## 2. Preparation: plug and lid
1.1 ESSAILEC[®] voltage sockets allow the simultaneous testing operations of 1 to 4 independent circuits on the same socket.
1.2 The lid is installed on the socket and can be sealed to prevent unauthorized access. The socket circuits are closed and signals flow from
2.1 The lid is removed.
2.2 Connect the ESSAILEC[®] test plug leads to the test set.
current transformers to the equipment to be tested.
## 5. Back to normal service
**==> picture [41 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
5<br>Back to<br>normal<br>service<br>**----- End of picture text -----**<br>
5.1 Plug removal closes back the socket contacts and signals flow again through the socket.
5.2 Lid is put back in place.
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
4
3. Test phase: Make 4.1 Measurement: test phase - Break 1 3 2 1 Measure “a COR-T-R5-2.2 ~~=~~ During plug insertion, plug pins make contact with socket When the plug is fully inserted in the pins (1). Contacts remain closed and the signals flow has socket, inner mobile contacts (2) are
When the plug is fully inserted in the socket, inner mobile contacts (2) are pushed down by plug’s plastic leads (3) and the four circuits are opened simultaneously. Signals are derived into the plug towards the test set. The equipment to be tested is no more energized.
not changed.
**==> picture [159 x 259] intentionally omitted <==**
**----- Start of picture text -----**<br>
3<br>Test phase:<br>Make<br>_<br>4<br>Test phase:<br>Break<br>**----- End of picture text -----**<br>
4.2 Injection or equipment replacement: test phase - Break
**==> picture [24 x 71] intentionally omitted <==**
**----- Start of picture text -----**<br>
Injection<br>Measure<br>**----- End of picture text -----**<br>
In a second step or simultaneously, voltage injection can be done on the protection relay side (4).
PAGE 33
**Voltage transformers application** ESSAILEC[®] sockets for voltage transformers - Make before break
4
## Description
**==> picture [85 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
x4<br>: : : } Q =<br>|<br>*O2@c0.97 aebehead<br>ot eee 1SNC169116V0014<br>**----- End of picture text -----**<br>
TC-E-VA
Short-circuited contacts for measurement, calibration and distribution applications.
Make before break principle:
- The circuit is automatically shorted with the insertion of the plug.
- The circuit closes automatically when the plug is removed.
- This system guarantees a complete safety.
- By convention grey coding is for voltage circuits and blue coding is for polarity circuits.
## Main technical data
## Mounting instructions
|Connecting capacity<br>IEC 947-1<br>Screw clamp<br>(VL)<br>Rigid - Solid / Stranded<br>0.2 ... 6 mm²<br>Flexible<br>0.22 ... 4 mm²<br>~~i~~|Connecting capacity<br>IEC 947-1<br>Screw clamp<br>(VL)<br>Rigid - Solid / Stranded<br>0.2 ... 6 mm²<br>Flexible<br>0.22 ... 4 mm²<br>~~i~~|Connecting capacity<br>IEC 947-1<br>Screw clamp<br>(VL)<br>Rigid - Solid / Stranded<br>0.2 ... 6 mm²<br>Flexible<br>0.22 ... 4 mm²<br>~~i~~|Connecting capacity<br>IEC 947-1<br>Screw clamp<br>(VL)<br>Rigid - Solid / Stranded<br>0.2 ... 6 mm²<br>Flexible<br>0.22 ... 4 mm²<br>~~i~~|Connecting capacity<br>IEC 947-1<br>Screw clamp<br>(VL)<br>Rigid - Solid / Stranded<br>0.2 ... 6 mm²<br>Flexible<br>0.22 ... 4 mm²<br>~~i~~|Connecting capacity<br>IEC 947-1<br>Screw clamp<br>(VL)<br>Rigid - Solid / Stranded<br>0.2 ... 6 mm²<br>Flexible<br>0.22 ... 4 mm²<br>~~i~~|Connecting capacity<br>IEC 947-1<br>Screw clamp<br>(VL)<br>Rigid - Solid / Stranded<br>0.2 ... 6 mm²<br>Flexible<br>0.22 ... 4 mm²<br>~~i~~|Connecting capacity<br>IEC 947-1<br>Screw clamp<br>(VL)<br>Rigid - Solid / Stranded<br>0.2 ... 6 mm²<br>Flexible<br>0.22 ... 4 mm²<br>~~i~~|Connecting capacity<br>IEC 947-1<br>Screw clamp<br>(VL)<br>Rigid - Solid / Stranded<br>0.2 ... 6 mm²<br>Flexible<br>0.22 ... 4 mm²<br>~~i~~|Connecting capacity<br>IEC 947-1<br>Screw clamp<br>(VL)<br>Rigid - Solid / Stranded<br>0.2 ... 6 mm²<br>Flexible<br>0.22 ... 4 mm²<br>~~i~~|Connecting capacity<br>IEC 947-1<br>Screw clamp<br>(VL)<br>Rigid - Solid / Stranded<br>0.2 ... 6 mm²<br>Flexible<br>0.22 ... 4 mm²<br>~~i~~|Connecting capacity<br>IEC 947-1<br>Screw clamp<br>(VL)<br>Rigid - Solid / Stranded<br>0.2 ... 6 mm²<br>Flexible<br>0.22 ... 4 mm²<br>~~i~~|Connecting capacity<br>IEC 947-1<br>Screw clamp<br>(VL)<br>Rigid - Solid / Stranded<br>0.2 ... 6 mm²<br>Flexible<br>0.22 ... 4 mm²<br>~~i~~|Rail<br>Screw clamp|Rail<br>Screw clamp|~~Ls~~||G32, TH 35-7.5,<br>TH 35-15|G32, TH 35-7.5,<br>TH 35-15||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||Ring tongue<br>Flexible|||0.34 ... 10 mm²|||||||||Wire||||9.5 mm|||
||(VA)<br>Ø lughole size|||3 mm|||||||||stripping||||0.370 in|||
||Width|||7.5 mm|||||||||length|||||||
||Quick-connect<br>Flexible|||2.5||||||||||||||||
||Body|||Polycarbonate||||||||||||||||
||Conductiveparts|||Silver-plated|||||||||Tool||||Flat screwdriver|||
||Rated voltage|||400 V|||||||||||||Ø<br>4 mm|||
||Impulse withstand voltage|||4000 V|||||||||||||Ø<br>0.157 in|||
||Pollution degree|||3||||||||||||||||
||Rated current|||8 A||||||||||||||||
||Short-circuit current|||25 A/5 s ... 800 A/25 ms|||||||||Torque||||0.5 ... 0.8 Nm|||
||Storage temperature range|||-25 ... +70 °C|-25 ... +70 °C||-25 ... +70 °C||||||||||4.4 ... 7.1 lb.in|||
||Workingtemperature range|||-10 ... +55 °C|-10 ... +55 °C||-10 ... +55 °C|||||||||||||
||Protection without lid / with lid<br>Codingcolor|||IP20 / IP40<br>Grey<br>- Blue<br>~~Oo~~||||- Blue<br>~~Oo~~||||||||||||
||Ordering details|||||||||||Compatible products||||||||
||Color<br>Type|Part Number|||||Pkg||Weight|||Lid|Cover|Universal||Pre-wired plugs||||
||||||||qty||1 pce g|||||plug||2x4poles||4poles||
||Flush mounting|||||||||||||||||||
||Ring-tongue|||||||||||||||||||
||Grey<br>TC-E-VA|1SNA166747R0200|||||1||140|||CPT-1|–|FI-2/4-DIA4||COR-T-R5-2.2||COR-T-4-4||
||TC-E-VA-2-2|1SNA166627R2200|||||1||150|||Lid +||||||||
||TC-E-VA-R2-2.2|1SNA166977R0000|||||50||150|||coding||||||||
|||||||||||||included||||||||
||Blue<br>PC-E-VA<br>o|1SNA166763R0200|||||1||145|||CPP-1||||COR-P-R1-8.8||–||
||PC-E-VA-8.8|1SNA166630R0100|||||1||200|||Lid +||||||||
|||||||||||||coding||||||||
|||||||||||||included||||||||
||Quickconnect|||||||||||||||||||
||Grey<br>TC-E-C5A-2.2<br>1SNA166628R0300<br>Base / Half-base mounting<br>B||||||1||170||Lid +<br>coding<br>included<br>–<br>FI-2/4-DIA4<br>COR-T-R5-2.2<br>COR-T-4-4<br>~~Pf fof |~~|||||||||
||Screw clamp|||||||||||||||||||
||Grey<br>TC-DS-VL|1SNA166742R0500|||||1||100|||CPT-1|CPT-5 (1)|FI-2/4-DIA4||COR-T-R5-2.2||COR-T-4-4 (2)||
||TC-S-INF-VL-2.2|1SNA166948R0400|||||1||170|||–|Cover +|||||COR-T-4-4||
||||||||||||||coding|||||||
||||||||||||||included|||||||
||Blue<br>PC-DS-VL<br>Oo|1SNA166758R1500|||||1||130|||CPT-1|–|||COR-P-R1-8.8||–||
||Ring-tongue|||||||||||||||||||
||Grey<br>TC-D-VA<br>Blue<br>PC-D-VA<br>TH35 rail mounting<br>~~Oo~~<br>~~B~~|1SNA166748R1300<br>1SNA166764R0300|||||1<br>1||147<br>115||CPP-1<br>–<br>FI-2/4-DIA4<br>~~ee~~<br>~~oo~~|||||COR-T-R5-2.2<br>COR-P-R1-8.8 <br>~~ee~~||COR-T-4-4 (2)<br> –||
||Screw clamp|||||||||||||||||||
||Grey<br>TC-TH35-VL|1SNA166964R0000|||||1||114|||CPT-1|CPT-5|FI-2/4-DIA4||COR-T-R5-2.2||COR-T-4-4||
||(1) Compatible only in base mounting option.|||||||||||||||||||
||(2) Compatible with some restrictions, please contact us.||(2) Compatible with some restrictions, please contact us.|||||||||||||||||
||Information on pre-wired plugs: Please refer to page "ESSAILEC®pre-wired plugs for voltage transformers".||||||||||||||||||1SNC169020S0201|
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**Voltage transformers application** ESSAILEC[®] sockets for voltage transformers - Make before break
4
**==> picture [84 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2 3<br>4 6 7<br>5<br>**----- End of picture text -----**<br>
|Description<br>~~oo~~|Type<br>~~oo~~|Part Number<br>~~oo~~|~~oo~~|Pkg<br>qty<br>~~oo~~|Weight<br>1pceg<br>~~oo~~|
|---|---|---|---|---|---|
|1<br>Interlockingpeg<br>For 2 sockets assembly<br>~~oo~~|CVABM<br>~~oo~~|1SNA183436R0500<br>~~oo~~|~~oo~~|10<br>~~oo~~|0.4<br>~~oo~~|
|2<br>Mounting kits<br>For TH35 rail (a)<br>3<br>For DIN 1 rail (a)<br>4<br>For ring-tongue flush mounting(b)|KEM-3|1SNA166962R0000||10|24|
||FX|1SNA167682R2300||10|20|
||KEM-1|1SNA166928R2000||50|18|
|6<br>Lateral jumper bars Compatible with ring-tongue connection only (VA) (b)<br>7<br>Compatible with screw connection only (VL); IP20 (c)|PCVA|1SNA167496R1100||10|1|
||PCVL|1SNA167681R2200||10|1|
|5<br>Jumper bars<br>For two sockets screw connection type (c)<br>~~ee~~|BJ-VL<br>~~ee~~|1SNA167680R0500<br>~~ee~~|~~ee~~|10<br>~~ee~~|1<br>~~ee~~|
(c) compatible with screw connection type socket only (VL).
## Compatible products
**==> picture [81 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lid Cover<br>CPC-1 CPC-7<br>**----- End of picture text -----**<br>
**==> picture [311 x 22] intentionally omitted <==**
**----- Start of picture text -----**<br>
Universal plug Plug 2x4 poles Plug 4 poles<br>FI-2/4-DIA4 COR-T-R5-2.2 COR-T-4-4<br>Design for insertion 01-02-03-04<br>**----- End of picture text -----**<br>
## Connection technologies
**==> picture [313 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ring-tongue Screw clamp Quick-connect<br>**----- End of picture text -----**<br>
PAGE 35
**Voltage transformers application**
Break before make test principle
4 ;
## Simultaneous measurement and injection with 2x4 poles test plug
**==> picture [373 x 201] intentionally omitted <==**
**----- Start of picture text -----**<br>
01<br>02<br>03<br>04<br>1<br>2<br>3<br>4<br>Y<br>COR-T-R5-2.2 1 01<br>2 02<br>iin 3 03<br>N L1 L2 L3 4 04<br>co 1 01 |<br>| 2 02 |<br>| 3 03 \<br>| 4 04 |<br>Test equipment Injection equipment<br>Equipment<br>**----- End of picture text -----**<br>
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
Break before make test principle
4
## Measurement or/and injection with 4 poles test plugs
**==> picture [464 x 245] intentionally omitted <==**
**----- Start of picture text -----**<br>
FIT-1/4-D<br>Customized plug to be<br>wired by user.<br>1 01<br>2 02<br>3 03<br>4 04<br>FIT-1/4-G 1 01<br>2 02<br>Mi 3 03<br>N L1 L2 L3 4 04<br>oT 1 01<br>| 2 02 |<br>| 3 03 '<br>|<br>4 04 |<br>Test equipment Injection equipment<br>Equipment<br>**----- End of picture text -----**<br>
PAGE 37
**Voltage transformers application** Break before make test principle - With 2x4 or 4 poles test plug
## Applications
- Measurement on VT’s
- Injection
- Equipment replacement
## 1. Normal service
## 2. Preparation: plug
## Connect the ESSAILEC[[®]] test
1.1 ESSAILEC[®] voltage sockets 1.2 The lid is installed on the Connect the ESSAILEC[[®]] test allow the simultaneous testing opsocket and can be sealed to preplug leads to the test set. erations of 1 to 4 independent cirvent unauthorized access. The cuits on the same socket. socket has no mobile contacts (closed style) (1). Circuit continuity is ensured by the lid equipped with built- in contact 4 pins (2). Ls 1 service 5. Back to normal service 5.1 When the plug is removed, 5.2 When lid is put back in place, signals are disconnected. signals flow again through the
5.2 When lid is put back in place, signals flow again through the socket.
**==> picture [41 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
5<br>Back to<br>normal<br>service<br>**----- End of picture text -----**<br>
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
4
## 3. Test phase: Break
4. Simultaneous measurement and injection Test phase: Make with 2x4 poles test plugs
**==> picture [24 x 72] intentionally omitted <==**
**----- Start of picture text -----**<br>
Injection<br>Measure<br>**----- End of picture text -----**<br>
**==> picture [122 x 30] intentionally omitted <==**
**----- Start of picture text -----**<br>
Measure<br>COR-T-R5-2.2<br>**----- End of picture text -----**<br>
Removing of the lid opens the cir4.1 The plug is fully inserted in the socket, the sigcuit. nals are derived into the plug towards the test set.
4.2 While the plug is still in place simultaneous injection can be realized on the equipment.
The device to be tested is then isolated from the power supply (VT) and is no longer energized. OR 4. Separated measurement and injection Test phase: Make with 4 poles test plugs 3 Test phase: Make FIT-1/4-G Design for insertion 1-2-3-4 ay 4 COR-T-4-4 \_= Us Test phase: Design for Break insertion 01-02-03-04 4.1 The plug is fully inserted in the FIT-1/4-G socket, the signals are derived Design for into the plug towards the test set. insertion 1-2-3-4
Injection COR-T-4-4 Us Design for insertion 01-02-03-04 Measure
**==> picture [190 x 45] intentionally omitted <==**
**----- Start of picture text -----**<br>
4.2 While the plug is still in<br>FIT-1/4-G<br>Design for place, a second plug can be in-<br>insertion 1-2-3-4 stalled for injection on the<br>equipment.<br>**----- End of picture text -----**<br>
PAGE 39
**Voltage transformers application** ESSAILEC[®] sockets for voltage transformers - Break before make
4 ’
## Description
Opened type contacts for measurement and calibration applications.
**==> picture [93 x 136] intentionally omitted <==**
**----- Start of picture text -----**<br>
x4<br>iiteel<br>ch? Fe ee<br>e” “<P<br>TO-E-VA<br>1SNC169300V0014<br>**----- End of picture text -----**<br>
Break before make principle:
- The connection is made thanks to the lid: the removing of the lid opens the circuit. So the device is isolated from power supply to be tested.
- The circuit is closed only when the lid is reinstalled.
- By convention, grey coding is for voltage circuits blue coding is for polarity circuits and orange coding is for trip circuits.
|1SNC169300V0014|• By convention, grey coding is for voltage circuits blue coding is for polarity circuits and orange coding is for<br>trip circuits.|• By convention, grey coding is for voltage circuits blue coding is for polarity circuits and orange coding is for|• By convention, grey coding is for voltage circuits blue coding is for polarity circuits and orange coding is for|• By convention, grey coding is for voltage circuits blue coding is for polarity circuits and orange coding is for|• By convention, grey coding is for voltage circuits blue coding is for polarity circuits and orange coding is for|• By convention, grey coding is for voltage circuits blue coding is for polarity circuits and orange coding is for|• By convention, grey coding is for voltage circuits blue coding is for polarity circuits and orange coding is for|• By convention, grey coding is for voltage circuits blue coding is for polarity circuits and orange coding is for|• By convention, grey coding is for voltage circuits blue coding is for polarity circuits and orange coding is for|• By convention, grey coding is for voltage circuits blue coding is for polarity circuits and orange coding is for|• By convention, grey coding is for voltage circuits blue coding is for polarity circuits and orange coding is for|• By convention, grey coding is for voltage circuits blue coding is for polarity circuits and orange coding is for|• By convention, grey coding is for voltage circuits blue coding is for polarity circuits and orange coding is for|• By convention, grey coding is for voltage circuits blue coding is for polarity circuits and orange coding is for|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|1SNC169300V0014|Main technical data||||||||||||Mounting instructions||
||Connecting capacity|||IEC 947-1|||||||||Rail|G32, TH 35-7.5,|
|||||||||||||||TH 35-15|
||Screw clamp<br>(VL)<br>Rigid - Solid / Stranded<br>Flexible|id - Solid / Stranded||0.2 ... 6 mm²<br>0.22 ... 4 mm²|||||||||Screw clamp||
||Ring tongue<br>(VA)<br>Flexible<br>Ø lughole size<br>~~———~~|||0.34 ... 10 mm²<br>3 mm|||||||||Wire<br>stripping<br>9.5 mm<br>0.370 in<br>~~—~~||
||Width|||7.5 mm|||||||||length||
||Body|||Polycarbonate|||||||||||
||Conductiveparts<br>Rated voltage|||Silver-plated<br>400 V|||||||||Tool<br>Flat screwdriver<br>Ø<br>4 mm<br>~~7,~~||
||Impulse withstand voltage|||4000 V||||||||||Ø<br>0.157 in|
||Pollution degree|||3|||||||||||
||Rated current|||8 A|||||||||||
||Short-circuit current<br>Storage temperature range<br>Workingtemperature range|||25 A/5 s ... 800 A/25 ms<br>-25 ... +70 °C<br>-10 ... +55 °C|||||||||Torque<br>0.5 ... 0.8 Nm<br>4.4 ... 7.1 lb.in<br>6||
||Protection without lid / with lid<br>IP20 / IP40<br>Codingcolor<br>Grey<br>- Blue<br>- Orange<br>~~—$§—} a a~~||||||||||||||
||Ordering details<br>Color<br>Type<br>Flush mounting<br>~~a a~~|Part Number||Pkg<br>qty||Weight<br>1 pce g||Compatible products<br>Lid<br>Cover<br>Universal<br>plug<br>Pre-wired plugs<br>2x4poles<br>4poles<br>~~-—————_——~~<br>|<br>|<br>|<br>||||||||
||Ring-tongue||||||||||||||
||Grey<br>TO-E-VA|1SNA166743R0600||1||170|||CPT-2||||–<br>FI-2/4-DIA4|COR-T-R5-2.2<br>(1)<br>COR-T-4-4|
||TO-E-VA-12.12|1SNA166925R1500||1||200|||Lid +|||||FIT-2/4-2 (3)|
||||||||||coding||||||
||||||||||included||||||
||Blue<br>PO-E-VA<br>1SNA166759R1600<br>1<br>170<br>Orange<br>DEO-E-VA<br>1SNA166878R0600<br>1<br>170<br>~~4~~<br>~~|~~<br>~~Pot] |)~~<br>~~|~~|||||||CPP-2<br>CPDE-2<br>~~|) ~~|||||COR-P-R1-8.8<br>(1)<br>–<br>FIDE-2/4 (3)<br> ~~yh~~||
||Base / Half-base mounting||||||||||||||
|Screw clamp<br>Grey<br>TO-DS-VL<br>1SNA166741R0400<br>TO-S-INF-VL-12.12 1SNA166723R2200<br>Blue<br>PO-DS-VL<br>1SNA166757R0400<br>i~~, ee~~<br>~~|e ee~~||||1<br>1<br>1||100<br>200<br>117|||CPT-2<br>–<br>CPP-2||||CPT-4 (2) FI-2/4-DIA4<br>Cover +<br>coding<br>included<br>–<br>–<br>FI-2/4-DIA4|COR-T-R5-2.2<br>(1)<br>COR-T-4-4<br>FIT-2/4-2 (3)<br>–<br>COR-P-R1-8.8<br>(1)|
||Ring-tongue||||||||||||||
|Eya|Grey<br>TO-D-VA<br>1SNA166744R0700<br>1<br>139<br>Blue<br>PO-D-VA<br>1SNA166760R1300<br>1<br>170<br>Orange<br>DEO-D-VA<br>1SNA166874R2200<br>1<br>140<br>Reverse mounting<br>Ring-tongue<br>Grey<br>TO-I-VA-2<br>1SNA166945R2100<br>1<br>190<br>(1) Compatible with some restrictions.<br>Oo~~ee~~<br>~~ee ~~<br>~~a |~~|||||||CPT-2<br>–<br>FI-2/4-DIA4<br>COR-T-R5-2.2<br>(1)<br>COR-T-4-4<br>CPP-2<br>COR-P-R1-8.8<br>(1)<br>–<br>CPDE-2<br>FIDE-2/4 (3)<br>CPT-2<br>–<br>FIT-2/4-I<br>FIT-2/4-I (3)<br>–<br> ~~eee~~<br>~~—_—_—~~|||||||
(1) Compatible with some restrictions.
(2) Compatible in base mounting only.
(3) Plug to be mounted / see customized plugs page.
Information on pre-wired plugs: Please refer to page "ESSAILEC[®] pre-wired plugs for voltage transformers".
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**Voltage transformers application** ESSAILEC[®] sockets for voltage transformers - Break before make
4
**==> picture [508 x 120] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Accessories|
|1|2|3|Description|Type|Part Number|Pkg|Weight|
|qty|1 pce|g|
|er|
|1|Interlocking peg|For 2 sockets assembly|CVABM|1SNA183436R0500|10|0.4|
|2|Mounting kits|For TH35 rail (a)|KEM-3|1SNA166962R0000|10|24|
|3|For DIN 1 rail (a)|FX|1SNA167682R2300|10|20|
|4|6|7|4|For ring-tongue flush mounting (b)|KEM-1|1SNA166928R2000|50|18|
|6|Lateral jumper bars|Compatible with ring-tongue connection only (VA) (b)|PCVA|1SNA167496R1100|10|1|
|7|Compatible with screw connection only (VL); IP20 (c)|PCVL|1SNA167681R2200|10|1|
|5|Jumper bars|For two sockets screw connection type (c)|BJ-VL|1SNA167680R0500|10|1|
|5|(a) compatible with base mounting only.|
|(b) compatible with ring-tongue connection type socket only (VA).|
|SS|——_——s|
**----- End of picture text -----**<br>
(c) compatible with screw connection type socket only (VL).
## Compatible products
**==> picture [81 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lid Cover<br>CPC-1 CPC-7<br>**----- End of picture text -----**<br>
**==> picture [311 x 22] intentionally omitted <==**
**----- Start of picture text -----**<br>
Universal plug Plug 2x4 poles Plug 4 poles<br>FI-2/4-DIA4 COR-T-R5-2.2 COR-T-4-4<br>Design for insertion 01-02-03-04<br>**----- End of picture text -----**<br>
## Connection technologies
**==> picture [165 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ring-tongue Screw clamp<br>**----- End of picture text -----**<br>
PAGE 41
**Voltage transformers application** Closed contact test principle - Measurement with 4 poles test plug
4 ’
**==> picture [375 x 304] intentionally omitted <==**
**----- Start of picture text -----**<br>
FIT-1/4-D<br>Customized plug to be<br>wired by user.<br>01<br>02<br>03<br>04<br>01<br>02<br>itt 03<br>N L1 L2 L3<br>04<br>|<br>1 01<br>2 02<br>es eeeee<br>3 03<br>eee| Oeae 4 aye, 04<br>|<br>ol dv avo)<br>Test equipment<br>Equipment<br>**----- End of picture text -----**<br>
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
4
**==> picture [73 x 43] intentionally omitted <==**
PAGE 43
**Voltage transformers application** Closed contact test principle - With 4 poles test plug
4
## Applications
- Measurement on VT's
## 1. Normal service
**==> picture [37 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
a 1<br>**----- End of picture text -----**<br>
1.1 ESSAILEC[®] voltage sockets allow the simultaneous testing operations of 1 to 4 independent circuits on the same socket.
## 4. Back to normal service
1.2 The lid is installed on the socket and can be sealed to prevent unauthorized access. The socket has no mobile contacts (closed style) (1). Circuit continuity is permanent, no possibility of disconnection.
**==> picture [83 x 159] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>Normal<br>service<br>4<br>Back to<br>normal<br>service<br>**----- End of picture text -----**<br>
**==> picture [393 x 21] intentionally omitted <==**
**----- Start of picture text -----**<br>
4.1 The plug is removed, and lid is put back in place, 4.2 The lid is put back in place.<br>signals never stop to flow through the socket.<br>**----- End of picture text -----**<br>
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
4
## 2. Preparation: plug and lid
**==> picture [87 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.1 The lid is removed.<br>**----- End of picture text -----**<br>
2.2 Connect the ESSAILEC[®] test plug leads to the test set.
**==> picture [100 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
2<br>Preparation<br>3<br>Test phase:<br>Make<br>**----- End of picture text -----**<br>
**==> picture [177 x 146] intentionally omitted <==**
**----- Start of picture text -----**<br>
3. Test phase: Make & Measure<br>hn<br>COR-T-4-4<br>Design for insertion 01-02-03-04<br>**----- End of picture text -----**<br>
The plug is fully inserted in the socket, the signals are derived into the plug towards the test set.
PAGE 45
**Voltage transformers application** ESSAILEC[®] sockets for voltage transformers – closed contact
4
## Description
x4
## Closed contact principle:
- The electrical connection is continuous. The circuit still closed during the testing operation.
- Closed contacts for measurement and distribution applications.
- By convention, grey coding is for voltage circuits blue coding is for polarity circuits and orange coding is for trip circuits.
=®s@ce.e | a-8Tene 8 © eeay |Tt F eS. & » TF-E-VA
|trip circuits.<br>~~—~~|trip circuits.<br>~~—~~|trip circuits.<br>~~—~~|trip circuits.<br>~~—~~|trip circuits.<br>~~—~~|trip circuits.<br>~~—~~|trip circuits.<br>~~—~~|trip circuits.<br>~~—~~|trip circuits.<br>~~—~~|trip circuits.<br>~~—~~|trip circuits.<br>~~—~~|trip circuits.<br>~~—~~|trip circuits.<br>~~—~~|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Main technical data<br>Mounting instructions<br>Connecting capacity<br>IEC 947-1<br>Rail<br>G32, TH 35-7.5,<br>TH 35-15<br>Screw clamp<br>(VL)<br>Rigid - Solid / Stranded<br>0.2 ... 6 mm²<br>Screw clamp<br>Flexible<br>0.22 ... 4 mm²<br>Ring tongue<br>(VA)<br>Flexible<br>0.34 ... 10 mm²<br>Wire<br>stripping<br>9.5 mm<br>Ø lughole size<br>3 mm<br>0.370 in<br>~~eee~~<br>~~a~~<br>~~|~~|||||||||||||
||Width|7.5 mm||||||length|||||
||Body|Polycarbonate|||||||||||
||Conductiveparts|Silver-plated||||||Tool|||Flat screwdriver||
||Rated voltage|400 V|||||||||Ø|4 mm|
||Impulse withstand voltage|4000 V|||||||||Ø|0.157 in|
||Pollution degree|3|||||||||||
||Rated current|8 A|||||||||||
||Short-circuit current|25 A/5 s ... 800 A/25 ms|25 A/5 s ... 800 A/25 ms|||||Torque|||0.5 ... 0.8 Nm|0.5 ... 0.8 Nm|
||Storage temperature range|-25 ... +70 °C|||||||||4.4 ... 7.1 lb.in|4.4 ... 7.1 lb.in|
||Workingtemperature range|-10 ... +55 °C|||||||||||
||Protection without lid / with lid|IP20 / IP40|||||||||||
||Codingcolor|Grey<br>- Blue<br>~~Oo~~|- Blue<br>~~o~~||- Orange<br>~~BH~~||||||||
||Ordering details|Ordering details|||||Compatible products|Compatible products|Compatible products||
|---|---|---|---|---|---|---|---|---|---|---|
||Color|Type<br>Part Number||Pkg|Weight||Lid|Cover|Universal|Pre-wired plugs|
|||qty<br>1 pce g<br>~~oT ~~||||~~...r~~|~~...r~~|~~...r~~|plug<br>~~...r~~|2x4poles<br>4poles<br>~~...r~~<br>i|
||Flush mounting|Flush mounting|||||||||
||Ring-tongue||||||||||
||Grey|TF-E-VA<br>1SNA166745R0000||1|170||CPT-1|–|–|–<br>COR-T-4-4|
||Blue|PF-E-VA<br>1SNA166761R0000<br>Bo||1|170||CPP-1|||FIP-1/4-D (1)<br>FIP-1/4-G(1)|
||Base / Half-base mounting|Base / Half-base mounting|||||||||
||Screw clam|Screw clamp|||||||||
||Grey<br>Blue|TF-DS-VL<br>1SNA166503R2700<br>PF-DS-VL<br>1SNA166506R2200<br>Oo<br>a||1<br>1|120<br>117||CPT-1<br>CPP-1|CPT-5 (2) <br>–|–|–<br>COR-T-4-4<br>FIP-1/4-D (1)<br>FIP-1/4-G(1)|
||Ring-tongue||||||||||
||Grey|TF-D-VA<br>1SNA166746R0100<br>Bo||1|119||CPT-1|–|–|–<br>COR-T-4-4|
|Blue<br>PF-D-VA<br>1SNA166762R0100<br>1<br>140<br>CPP-1<br>FIP-1/4-D (1)<br>FIP-1/4-G (1)<br>Orange<br>DEF-D-VA<br>1SNA166896R1100<br>1<br>140<br>CPDE-1<br>Bo~~|GS~~|||||||||||
(1) Plug to be mounted / see customized plugs page.
(2) Compatible in base mounting only.
Information on pre-wired plugs: Please refer to page "ESSAILEC[®] pre-wired plugs for voltage transformers".
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**Voltage transformers application** ESSAILEC[®] sockets for voltage transformers – closed contact
4
**==> picture [84 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2 3<br>4 6 7<br>5<br>**----- End of picture text -----**<br>
|Description<br>~~er~~|Type<br>~~er~~|Part Number<br>~~er~~|~~er~~|Pkg<br>qty<br>~~er~~|Weight<br>1pceg<br>~~er~~|
|---|---|---|---|---|---|
|1<br>Interlockingpeg<br>For 2 sockets assembly<br>~~er~~|CVABM<br>~~er~~|1SNA183436R0500<br>~~er~~|~~er~~|10<br>~~er~~|0.4<br>~~er~~|
|2<br>Mounting kits<br>For TH35 rail (a)<br>3<br>For DIN 1 rail (a)<br>4<br>For ring-tongue flush mounting(b)|KEM-3|1SNA166962R0000||10|24|
||FX|1SNA167682R2300||10|20|
||KEM-1|1SNA166928R2000||50|18|
|6<br>Lateral jumper bars Compatible with ring-tongue connection only (VA) (b)<br>7<br>Compatible with screw connection only (VL); IP20 (c)|PCVA|1SNA167496R1100||10|1|
||PCVL|1SNA167681R2200||10|1|
|5<br>Jumper bars<br>For two sockets screw connection type (c)|BJ-VL|1SNA167680R0500||10|1|
(a) compatible with base mounting only.
(b) compatible with ring-tongue connection type socket only (VA).
(c) compatible with screw connection type socket only (VL).
## Compatible products
**==> picture [81 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lid Cover<br>CPC-1 CPC-7<br>**----- End of picture text -----**<br>
**==> picture [86 x 22] intentionally omitted <==**
**----- Start of picture text -----**<br>
Plug 4 poles<br>COR-T-4-4<br>Design for insertion 01-02-03-04<br>**----- End of picture text -----**<br>
## Connection technologies
**==> picture [165 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ring-tongue Screw clamp<br>**----- End of picture text -----**<br>
PAGE 47
**Voltage transformers application** ESSAILEC[®] sockets for voltage transformers – independent circuits
4 ’
## Description
**==> picture [7 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
x4<br>**----- End of picture text -----**<br>
Four independent circuits for voltage measurement.
Test directly performed on the four built-in dia. 4mm test sockets (no plug required). Test sockets color coding :
• U1- brown,
- U2-black,
- U3-red,
• U4-blue.
The socket is supplied with a compact cover and sealing option (no coding required).
|• U3-red,<br>• U4-blue.<br>The socket is supplied with a compact cover and sealing option (no coding required).<br>1SNC169294V0014<br>2<br>e<br>®<br>@|• U3-red,<br>• U4-blue.<br>The socket is supplied with a compact cover and sealing option (no coding required).<br>1SNC169294V0014<br>2<br>e<br>®<br>@|• U3-red,<br>• U4-blue.<br>The socket is supplied with a compact cover and sealing option (no coding required).<br>1SNC169294V0014<br>2<br>e<br>®<br>@|
|---|---|---|
|Main technical data<br>Mounting instructions<br>Connecting capacity<br>IEC 947-1<br>Rail<br>TH 35-7.5,<br>TH 35-15<br>®<br>@<br>4t<br>€ |<br>~~a~~<br>~~|~~<br>~~J~~<br>~~S~~<br>~~a~~<br>~~u~~|||
|TT4-S-VL-INF||Screw clamp<br>(VL)<br>Rigid - Solid / Stranded<br>0.2 ... 6 mm²<br>Wire stripping<br>length<br>9.5 mm<br>Flexible<br>0.22 ... 4 mm²<br>0.370 in<br>~~—~~|
|||with non insulated ferrule<br>0.22 ... 4 mm²|
|||Body<br>Polycarbonate|
|||Conductiveparts<br>Silver-plated<br>Tool<br>Flat screwdriver<br>Rated voltage<br>400 V<br>Ø<br>4 mm<br>~~Q~~|
|||Impulse withstand voltage<br>4000 V<br>Ø<br>0.157 in|
|||Pollution degree<br>3|
|||Rated current<br>8 A|
|||Short-circuit current<br>25 A/5 s ... 800 A/25 ms<br>Torque<br>0.5 ... 0.8 Nm<br>Storage temperature range<br>-25 ... +70 °C<br>4.4 ... 7.1 lb.in<br>Workingtemperature range<br>10 ... +55 °C<br>~~©~~|
|||Protection without cover/ lid<br>IP20|
Ordering details Compatible products Color Type Part Number Pkg Weight Lid / Cover Cover qty 1 pce g Base / Half-base mounting Grey TT4-S-VL-INF 1SNA166972R0000 40 114 Included included ~~Sa~~ Information on pre-wired plugs: Please refer to page "ESSAILEC[®] pre-wired plugs for voltage transformers".
## Accessories
**==> picture [84 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2 3<br>4 5 6<br>a<br>7<br>**----- End of picture text -----**<br>
|Accessories||||||
|---|---|---|---|---|---|
|Description|Type|Part Number||Pkg<br>qty|Weight<br>1pceg|
|1<br>Interlockingpeg<br>For 2 sockets assembly|CVABM|1SNA183436R0500||10|0.4|
|2<br>Mounting kits<br>For TH35 rail (a)<br>3<br>For DIN 1 rail (a)<br>4<br>For ring-tongue flush mounting(b)|KEM-3|1SNA166962R0000||10|24|
||FX|1SNA167682R2300||10|20|
||KEM-1|1SNA166928R2000||50|18|
|5<br>Jumper bars<br>For two sockets screw connection type (c)|BJ-VL|1SNA167680R0500||10|1|
|6<br>Lateral jumper bars Compatible with ring-tongue connection only (VA) (b)<br>7<br>Compatible with screw connection only (VL); IP20 (c)<br>~~ne~~|PCVA|1SNA167496R1100||10|1|
||PCVL<br>~~ne~~|1SNA167681R2200<br>~~ne~~|~~ne~~|10<br>~~ne~~|1<br>~~ne~~|
(a) compatible with base mounting only.
(b) compatible with ring-tongue connection type socket only (VA).
(c) compatible with screw connection type socket only (VL).
**==> picture [123 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Side view left Side view right<br>**----- End of picture text -----**<br>
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**Voltage transformers application** ESSAILEC[®] pre-wired plugs for voltage transformers
4
## Description
- Standard voltage plugs are compatible with ESSAILEC[®] voltage sockets.
- Plugs are ready to use with contact pins (BRE...) , coding, cables and test plugs assembled to ease your test operations.
## Main technical data
|test operations.<br>Main technical data||
|---|---|
|Connecting capacity|IEC 947-1|
|Body|Polycarbonate|
|Conductiveparts|Silver-plated|
|Rated voltage|400 V|
|Impulse withstand voltage|4000 V|
|Pollution degree|3|
|Rated current|15 A|
|Short-circuit current|25 A/5 s ... 800 A/25 ms|
|Storage temperature range|-25 ... +70 °C|
|Workingtemperature range|-10 ... +55 °C|
|Plug 2x4 pins,<br>with direct insertion Ø 4 mm test plug|FI-2/4-DIA4|1SNA167936R1100||1|62|
|---|---|---|---|---|---|
Continue on next page
PAGE 49
## **Voltage transformers application** ESSAILEC[®] pre-wired plugs for voltage transformers
4 :
|||||||Compatible|
|---|---|---|---|---|---|---|
|Ordering details||||||products|
|Description|Type|Part Number||Pkg|Weight|Socket|
|||||qty|1pceg||
|Plug 2x4 poles|||||||
|1 plug 2x4 pins PRECODED 2.2 / Grey|COR-T-R5-2.2|1SNA167933R1600||1|1070|TC-E-VA|
|4 x Ø 4 mm test plugs / Black||||||TC-E-VA-2.2|
|4 x Ø 4 mm test plugs / Red||||||TC-E-VA-R2-2.2|
|Conductors section: 2.5 mm²||||||TC-DS-VL|
|cable length: 2 m / 79"||||||TC-S-INF-VL-2.2|
|||||||TC-D-VA|
|||||||TC-TH35-VL|
|||||||TC-E-C5A-2.2|
|||||||TO-E-VA|
|||||||TO-E-VA-12.12|
|||||||TO-DS-VL|
|||||||TO-S-INF-VL-12.12|
|||||||TO-D-VA|
|1 plug 2x4 pins PRECODED 8.8 / Blue|COR-P-R1-8.8|1SNA166978R0000||1|1080|PC-E-VA|
|4 x Ø 4 mm test plugs / Black||||||PC-E-VA-8.8|
|4 x Ø 4 mm test plugs / Red||||||PC-DS-VL|
|Conductors section: 2.5 mm²||||||PC-D-VA|
|cable length: 2 m / 79"||||||PO-E-VA|
|||||||PO-DS-VL|
|||||||PO-D-VA|
|||||||PC-E-VA|
|||||||PC-E-VA-8.8|
|||||||PC-DS-VL|
|||||||PC-D-VA|
|||||||PO-E-VA|
|Plug 4 poles<br>1 plug 4 pins / Grey<br>Design for insertion 01-02-03-04 (D.<br>COR-T-4-4<br>1SNA167935R1000<br>1<br>500<br>~~rr~~||||||PO-DS-VL<br>PO-D-VA<br>TC-E-VA<br>TC-E-VA-2.2|
|design.)||||||TC-E-VA-R2-2.2|
|4 x Ø 4 mm test plugs / Black||||||TC-DS-VL|
|Conductors section: 2.5 mm²||||||TC-S-INF-VL-2.2|
|cable length: 2 m / 79"||||||TC-D-VA|
|||||||TC-TH35-VL|
|||||||TC-E-C5A-2.2|
|||||||TO-E-VA|
|||||||TO-E-VA-12.12|
|||||||TO-DS-VL|
|||||||TO-S-INF-VL-12.12|
|||||||TO-D-VA|
|||||||TF-E-VA|
|||||||TF-DS-VL|
|||||||TF-D-VA|
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**Voltage transformers application** ESSAILEC[®] customized plugs
4
## Description
To create a customized ESSAILEC[®] plug, according to the current socket chosen:
- Select a plug,
- Add contact pins (BRE...) and coding pins (COP...) if necessary,
- Choose the test plugs required by the measurement tool.
## Ordering details
|Plug 2 poles with 2.5 mm²<br>contact pins (BRE-T-2.5),<br>without coding pins|Grey<br>~~o~~|~~o~~|FIT-2/1-1|1SNA166821R1500||1|30|
|---|---|---|---|---|---|---|---|
||Red<br>~~o~~|~~o~~|FIT-2/1-2|1SNA166644R0300||1|30|
Plugs without contact pins (contact pins BRE..., to be ordered separately)
2x4 poles
|2x4 polespolesoles||||||||
|---|---|---|---|---|---|---|---|
|Plugs 2x4 poles, long cover,<br>with 2 coding<br>pins (COP-FI-1) and 8 locking<br>pin.<br>Contacts pins (BRE-T...) to be<br>ordered<br>separately.|Grey||FIT-2/4-2|1SNA166937R1100||1|105|
||Blue<br>im|im|FIP-2/4-2|1SNA166939R2300||1|105|
|Plug 2 poles with 2.5 mm²<br>contact pins<br>(BRE-T-2.5), without coding<br>pins|Orange<br>a|a|FIDE-2/4-2|1SNA166943R2700||1|105|
Continue on next page
PAGE 51
|||**Voltage transformers application**|||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|||ESSAILEC®customized plugs|||||||||
|Ordering details<br>Compatible<br>products<br>Description<br>Color<br>Type<br>Part Number<br>Pkg<br>Weight<br>~~a~~|||||||||||
|||qty<br>1 pceg<br>Socket<br>Plugs 2x4 poles, short cover,<br>with 2 coding<br>pins (COP-FI-1) and 8 locking<br>pins.<br>Contacts pins (BRE-T...) to be<br>ordered<br>separately.<br>Grey<br>FIT-2/4-1<br>1SNA166550R0100<br>1<br>91<br>TC-E-VA<br>TC-E-VA-2.2<br>TC-E-VA-R2-2.2<br>TC-DS-VL<br>TC-S-INF-VL-2.2<br>TC-D-VA<br>TC-TH35-VL<br>TC-E-C5A-2.2<br>TO-E-VA<br>TO-E-VA-12.12<br>TO-DS-VL<br>TO-S-INF-VL-12.12<br>TO-D-VA<br>Blue<br>FIP-2/4-1<br>1SNA166559R0600<br>1<br>91<br>PC-E-VA<br>PC-E-VA-8.8<br>PC-DS-VL<br>PC-D-VA<br>PO-E-VA<br>PO-DS-VL<br>PO-D-VA<br>~~6~~<br>~~fy~~|||||||||
||||Orange||FIDE-2/4|1SNA166877R2500||1|91|DEO-E- A<br>DEO-D-VA|
|4||Plug 4 poles - insertion 01-02-<br>03-04, with<br>1 coding pin (COP-FI-1) and 4<br>locking pins.<br>Contacts pins (BRE-T...) to be<br>ordered<br>separately.<br>4 Poles<br>Plug 4 poles - insertion 1-2-3-<br>4, with 1|Grey<br>Grey||FIT-2/4-I<br>FIT-1/4-G|1SNA166672R0700<br>1SNA166547R2200||1<br>1|60<br>60|TO-I-VA-2<br>TC-E-VA<br>TC-E-VA-2.2|
|||coding pin (COP-FI-1) and 4||||||||TC-E-VA-R2-2.2|
|||locking pins.||||||||TC-DS-VL|
|||Contacts pins (BRE-T...) to be||||||||TC-S-INF-VL-2.2|
|||ordered||||||||TC-D-VA|
|||separately.||||||||TC-TH35-VL|
|||||||||||TC-E-C5A-2.2|
|||||||||||TO-E-VA|
|||||||||||TO-E-VA-12.12|
|||||||||||TO-DS-VL|
|||||||||||TO-S-INF-VL-12.12|
|||||||||||TO-D-VA|
|||||||||||TF-E-VA|
|||||||||||TF-DS-VL|
|||||||||||TF-D-VA|
||||Blue||FIP-1/4-G|1SNA166556R2300||1|60|PC-E-VA|
|||||||||||PC-E-VA-8.8|
|||||||||||PC-DS-VL|
|||||||||||PC-D-VA|
|||||||||||PO-E-VA|
|||||||||||PO-DS-VL|
|||||||||||PO-D-VA|
|||PF-E-VA<br>PF-DS-VL<br>PF-D-VA<br>Orange<br>FIDE-1/4-G<br>1SNA166898R2300<br>1<br>40<br>DEO-D-VA<br>DEF-D-VA<br>DEO-E-VA<br>Continue on next page<br>~~_SS~~|||||||||
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**Voltage transformers application** ESSAILEC[®] customized plugs
4
|Ordering details|||||||||Compatible|
|---|---|---|---|---|---|---|---|---|---|
|Description|Color|||Type|Part Number||Pkg|Weight|products|
|qty<br>1 pceg<br>Plug 4 poles - insertion 01-02-<br>03-04, with<br>Grey<br>FIT-1/4-D<br>1SNA166546R2100<br>1<br>60<br>~~—_>a~~|||||||||Socket<br>TC-E-VA<br>TC-E-VA-2.2|
|1 coding pin (COP-FI-1) and 4|||||||||TC-E-VA-R2-2.2|
|locking pins.|||||||||TC-DS-VL|
|Contacts pins (BRE-T...) to be|||||||||TC-S-INF-VL-2.2|
|ordered|||||||||TC-D-VA|
|separately.|||||||||TC-TH35-VL|
||||||||||TC-E-C5A-2.2|
||||||||||TO-E-VA|
||||||||||TO-E-VA-12.12|
||||||||||TO-DS-VL|
||||||||||TO-S-INF-VL-12.12|
||||||||||TO-D-VA|
||||||||||TF-E-VA|
||||||||||TF-DS-VL|
||||||||||TF-D-VA|
||Blue|im||FIP-1/4-D|1SNA166555R2200||1|60|PC-E-VA<br>PC-E-VA-8.8|
||||||||||PC-DS-VL|
||||||||||PC-D-VA|
||||||||||PO-E-VA|
||||||||||PO-DS-VL|
||||||||||PO-D-VA|
||||||||||PF-E-VA|
||||||||||PF-DS-VL|
||||||||||PF-D-VA|
||Orange|a||FIDE-1/4-D|1SNA166897R1200||1|40|DEO-D-VA<br>DEF-D-VA|
||||||||||DEO-E-VA|
PAGE 53
**Voltage transformers application** ESSAILEC[®] customized plugs
4
|1<br>2<br>3<br>4<br>5<br>6|1<br>2<br>3<br>4<br>5<br>6||Accessories|Accessories|||||Weight<br>1pceg<br>2<br>2.9<br>3<br>2.6<br>2<br>3<br>3<br>24<br>478<br>0.4<br>11<br>10<br>2.3|Compatible<br>products<br>Socket|
|---|---|---|---|---|---|---|---|---|---|---|
|||||Description|Type|Part Number||Pkg<br>qty|||
||||BR|E contactpins|||||||
|||||Pin 0.34 mm²|BRE-T-0.34|1SNA168160R1400||50||–|
|||||Pin 0.75 mm²|BRE-T-0.75|1SNA167779R1300||50||–|
|||||Pin 1 mm²|BRE-T-1|1SNA164921R1700||50||–|
|||||Pin 1.5 mm²|BRE-T-1.5|1SNA164922R1000||50||–|
|||||Pin 2.5 mm²|BRE-T-2.5|1SNA164923R1100||50||–|
|||||Pin 4 mm²|BRE-T-4|1SNA166980R0000||100||–|
|||||Pin 6 mm²|BRE-T-6|1SNA168147R0300||50||–|
||||Tools for contactpins||||||||
||||1<br>Pin extraction tool||EXBR1|1SNA167008R0300||1||–|
||||2<br>Crimpingtool for BRE pins 1 to 2.5 mm² (1)||PSC|1SNA173181R1300||1||–|
||||3<br>Lockingsleeve for contact pin||DLVR|1SNA167971R2400||10||–|
||||Dia 4 mm test plugs||||||||
||||4<br>IP20 with mobile protection||FC4-1|1SNA167927R1000||10||–|
||||5<br>IP20 with permanent protection||FC4-5|1SNA167931R1400||10||–|
||||Coding pins||||||||
||||6<br>Plugcodingpin||COP-FI-1|1SNA167378R1100||10||–|
||||(1) Refering to 1SNC169040D1702 to fnd other crimping tools||||||||
Pin installation on plugs
**==> picture [265 x 157] intentionally omitted <==**
**----- Start of picture text -----**<br>
Locking pin, DLVR supplied with<br>the plug<br>BRE pin<br>**----- End of picture text -----**<br>
**==> picture [73 x 43] intentionally omitted <==**
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**For all applications** ESSAILEC[®] protection lids and covers
5
## Description
During normal operation, lids and covers ensure protection of the test sockets from dust and unauthorized use.
According to the mounting choice, two options available:
- a lid for all types of mounting
- a cover required for base mounting ("S/DS" mounting coding)
In the case of opened contacts sockets, electrical continuity covers or lids are required. The electrical continuity is provided thanks to inner pins and linking bar.
## Main technical data
|||Main technical data||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|||Protection with cover / lid|IP40|||||||||
|||Ordering details||||||||||
|||Description|Color||||Type|Part Number||Pkg|Weight|
|||||||||||qty|1pceg|
|||Lid||||||||||
|Protectinglid for current sockets<br>Green<br>CPC-1<br>1SNA166578R0100<br>1<br>30<br>Protectinglid for voltage sockets<br>Grey<br>CPT-1<br>1SNA166646R0500<br>1<br>30<br>Protectinglid for trip sockets<br>Blue<br>CPP-1<br>1SNA166647R0600<br>1<br>30<br>~~2a~~<br>~~3~~<br>~~|~~<br>~~o~~||||||||||||
|||Protectinglid for polarity sockets|Orange||||CPDE-1|1SNA166876R2400||1|30|
|Cwsailee ) <br>itt||<br>||Lid for RJ45 socket (spare part)<br>Lid with electrical continuity<br>Protectinglid for voltage sockets<br>Protectinglid for polarity sockets<br>~~a~~|Grey<br>Grey<br>Blue<br>~~a~~<br>~~a~~|~~a~~<br>~~=~~||~~a~~|CPT-RJ45<br>CPT-2<br>CPP-2<br>~~a~~|1SNA167002R0000<br>1SNA166577R2000<br>1SNA166645R0400<br>~~a~~|~~a~~|1<br>1<br>1<br>~~a~~|25.4<br>40<br>40<br>~~a~~|
|||Protectinglid for trip sockets|Orange||||CPDE-2|1SNA166926R1600||1|40|
|Csscilee”||Cover<br>Protectingcover for current sockets|Green|~~=~~|||CPC-7 (1)|1SNA166734R2500||1|66|
|||Protectingcover for voltage sockets|Grey||||CPT-5|1SNA166930R2600||1|66|
|||Cover with electrical continuity||||||||||
|||Protectingcover for voltage sockets|Grey|o|||CPT-4|1SNA166733R2400||1|78|
(1) CPC-7 is compatible with CC-S-INF-VL-6.6 sockets.
PAGE 55
**ESSAILEC[®] multicircuits** Range 10, 20 points
## Description
- Designed for high density wiring inside panels.
- Alternative to large terminal strips.
- Allows easy circuits disconnection without wiring modification.
**==> picture [70 x 86] intentionally omitted <==**
**----- Start of picture text -----**<br>
M10-D-C5A<br>1SNC169118V0014<br>**----- End of picture text -----**<br>
Multi-circuit blocks can be mounted side by side for compact panel board wiring in replacement of large terminal strip.
Main technical data Mounting instructions Connecting capacity IEC 947-1 Socket Quick connect (C5A) 0.5 ... 0.8 Nm Wire stripping 9.5 mm M10-D-C5A Flexible 2.5 mm² length 0.370 in Plug Pin BRE Body Polycarbonate Conductive parts Silver-plated Rated voltage 400 V Impulse withstand voltage 4000 V Pollution de ~~==>~~ gree 3 Rated current 8 A Short-circuit current 25 A/5 s ... 800 A/25 ms Storage temperature range -25 ... +70 °C Working temperature range -10 ... +55 °C Protection without cover/ lid IP20 / IP40 ~~—_—_— =~~ Ordering details Compatible products Color Type Part Number Pkg Weight Plug Socket qty 1 pce g Sockets ~~|}~~ Half-base mounting Grey M10-D-C5A 1SNA166513R1000 10 60 FIM10-1 ~~-—~~ – Extension mounting M10-D-C5A Grey M10-P-C5A 1SNA166772R0300 10 66 – – Rack mounting Grey M10-R-C5A 1SNA166566R2500 10 60 FIM10-R – Reverse mounting t ~~a~~ Grey M10-I-C5A-1 1SNA166774R0500 10 100 FIM10-I-1 – M20-I-C5A M20-I-C5A 1SNA166777R0000 1 190 FIM20-I – ~~——S~~ Plugs Grey FIM10-1 1SNA166516R1300 10 55 – M10-D-C5A FIM10-R 1SNA166573R2400 1 54 – M10-R-C5A FIM10-I-1 1SNA166574R2500 1 30 – M10-I-C5A-1 FIM10-1 6 FIM20-I 1SNA166576R2700 1 53 – M20-I-C5A FIM20-I The various accessories necessary for each mounting option are supplied with the socket as well as the 2 coding pins COP-E-1 (see coding section). 1 2 ~~——~~ The BRT contacts pins are to be ordered separately. Accessories Description Type Part Number Pkg Weight qty 1 pce g For sockets 1 ~~OO~~ 1 For 2 sockets assembly CVABM 1SNA183436R0500 10 0.4 For plugs 2 Pin 0.34 mm² BRE-T-0.34 1SNA168160R1400 50 2 Pin 0.75 mm² BRE-T-0.75 1SNA167779R1300 50 2.9 2 Pin 1 mm² BRE-T-1 1SNA164921R1700 50 3 ~~Ss~~ Pin 1.5 mm² BRE-T-1.5 1SNA164922R1000 50 2.6 Pin 2.5 mm² BRE-T-2.5 1SNA164923R1100 50 2 Pin 6 mm² BRE-T-6 ~~= ===~~ 1SNA168147R0300 50 3 3 Pin extraction tool EXBR1 1SNA167008R0300 1 24 3 ~~<<~~ 4 4 Crimping tool for BRE pins 1 to 2.5 mm² (1) PSC 1SNA173181R1300 1 478
(1) Refering to 1SNC169040D1702 to find other crimping tools
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**Mounting instructions**
58
7
Mounting instructions for coding
Outer dimensions, mounting instructions 60
**==> picture [73 x 43] intentionally omitted <==**
PAGE 57
**ESSAILEC[®]** Mounting instructions for coding
7
**==> picture [482 x 525] intentionally omitted <==**
**----- Start of picture text -----**<br>
Socket coding pin<br>Plug coding pin<br>q pase—_ — !<br>Plug coding pin Socket coding pin<br>Coding pins Socket coding<br>symbol<br>2 4 6 8 10 12<br>Plug coding<br>COP-E-1 COP-FI-1<br>| GE B Eu G<br>2 4 6 8 10 12<br>These numbers correspond to the coding information<br>For instance:<br>CC-E-VA-6.6 corresponds to COR-C-R4-6.6<br>TC-E-VA-2.2 corresponds to COR-T-R5-2.2<br>**----- End of picture text -----**<br>
## Ordering details
|Ordering details|||||
|---|---|---|---|---|
|Description|Type|Part Number|Pkg|Weight|
||||qty|kg|
|Socket coding pin|COP-E-1|1SNA167379R1200|10|2.3|
|Plug coding pin|COP-FI-1|1SNA167378R1100|10|2.3|
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**ESSAILEC[®]** Mounting instructions for coding
7
## How to insert the coding pins?
**==> picture [73 x 83] intentionally omitted <==**
Step 1 - Socket
Choose a coding code for the socket. Then, insert the coding pin (COP-E-1) from below into the socket.
**==> picture [74 x 82] intentionally omitted <==**
**==> picture [57 x 72] intentionally omitted <==**
Step 2 - Plug
In order to guarantee a perfect compatibility between the socket coding and the plug coding, you have to:
1. Insert the coding pin for the plug (COP-FI-1) inside the socket.
**==> picture [243 x 185] intentionally omitted <==**
2. On a second time, connect the plug on the socket to insert the plug coding within the plug.
**==> picture [73 x 43] intentionally omitted <==**
PAGE 59
**ESSAILEC[®]** Outer dimensions
7
## Sockets
**==> picture [97 x 122] intentionally omitted <==**
Half-base mounting
**==> picture [9 x 13] intentionally omitted <==**
**----- Start of picture text -----**<br>
40<br>**----- End of picture text -----**<br>
Rack mounting
**==> picture [222 x 126] intentionally omitted <==**
**----- Start of picture text -----**<br>
44 49.5<br>40<br>63<br>80.2<br>**----- End of picture text -----**<br>
Base mounting
Base mounting with KEM-3
**==> picture [222 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
TH35 rail mounting RJ45<br>51.5<br>59<br>44<br>43.7<br>50<br>47.1<br>3<br>63 74<br>66.7<br>80.2<br>**----- End of picture text -----**<br>
**==> picture [65 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lids and covers<br>**----- End of picture text -----**<br>
**==> picture [53 x 111] intentionally omitted <==**
**==> picture [76 x 164] intentionally omitted <==**
**==> picture [144 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lid Cover<br>**----- End of picture text -----**<br>
**==> picture [73 x 43] intentionally omitted <==**
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**ESSAILEC[®]** Outer dimensions
7
Plugs
**==> picture [103 x 141] intentionally omitted <==**
Plug 2x4 poles long cover
**==> picture [95 x 147] intentionally omitted <==**
Plug 2x4 poles short cover
**==> picture [104 x 129] intentionally omitted <==**
Reverse mounting
**==> picture [73 x 43] intentionally omitted <==**
PAGE 61
**ESSAILEC[®]** Outer dimensions, mounting instructions
7
## Sockets
**==> picture [139 x 105] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 x M3<br>:<br>po 4 x M4<br>Ø 3.1<br>35<br>±0.1 73<br>56.5<br>=<br>=<br>**----- End of picture text -----**<br>
**==> picture [161 x 21] intentionally omitted <==**
**----- Start of picture text -----**<br>
Base mounting Base mounting<br>0.5 Nm < Tightening torque<br>< 0.8 Nm.<br>**----- End of picture text -----**<br>
Flush mounting
Flush mounting The flush mounting kit must be mounted on the socket prior to the installation on the panel. Tightening torque = 0.5 Nm maxi.
**==> picture [34 x 76] intentionally omitted <==**
**----- Start of picture text -----**<br>
44.5<br>89<br>**----- End of picture text -----**<br>
Half-base mounting - Rack mounting The rack mounting is supplied with 2 additional guiding pins. 0.5 Nm < Tightening torque < 0.8 Nm.
Flush mounting (RJ45)
Reverse mounting
Lids and covers
Flush mounting
Base mounting
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
**ESSAILEC[®] multicircuits** Outer dimensions, mounting instructions
7
Outer dimensions Sockets : Tyr M20-I-C5A M20-C5A M10-I-C5A-1 M10-D-C5A 20 points multicircuits half-base reverse 20 points multicircuits 10 points multicicuits 10 points multicircuits mounting socket half-base mounting socket half-base reverse mounting half-base mounting socket socket
Plugs ® ©+ 2 6 FIM20-I FIM20 FIM10-I-1 FIM10-1 20 points multicircuits 20 points multicircuits 10 points multicicuits 10 points multicircuits half-base reverse mounting half-base mounting plug half-base reverse half-base mounting plug mounting plug plug
## Mounting instructions
**==> picture [502 x 129] intentionally omitted <==**
**----- Start of picture text -----**<br>
4 x Ø 2.5 4 x Ø 2.5 2 x Ø 2.5 2 x Ø 2.5<br>20 points multicircuits 20 points multicircuits 10 points multicicuits 10 points multicircuits<br>half-base reverse mounting half-base mounting socket half-base reverse mounting half-base mounting socket<br>plug plug<br>= 22 = = 22 = =22= =22=<br>50 56.5 50 56.5 50 56.5 50 56.5<br>**----- End of picture text -----**<br>
PAGE 63
8
## **Index** Part Number classification
|1SNA164921R1700<br>BRE-T-1<br>54<br>1SNA164922R1000<br>BRE-T-1.5<br>54<br>1SNA164923R1100<br>BRE-T-2.5<br>54<br>1SNA166503R2700<br>TF-DS-VL<br>46<br>1SNA166506R2200<br>PF-DS-VL<br>46<br>1SNA166513R1000<br>M10-D-C5A<br>56<br>1SNA166516R1300<br>FIM10-1<br>56<br>1SNA166523R1200<br>CC-R-VA<br>22<br>1SNA166525R1400<br>FIC-2/4-1<br>26<br>1SNA166529R2000<br>FIC-2/4-R<br>26<br>1SNA166546R2100<br>FIT-1/4-D<br>53<br>1SNA166547R2200<br>FIT-1/4-G<br>52<br>1SNA166550R0100<br>FIT-2/4-1<br>52<br>1SNA166555R2200<br>FIP-1/4-D<br>53<br>1SNA166556R2300<br>FIP-1/4-G<br>52<br>1SNA166559R0600<br>FIP-2/4-1<br>52<br>1SNA166566R2500<br>M10-R-C5A<br>56<br>1SNA166573R2400<br>FIM10-R<br>56<br>1SNA166574R2500<br>FIM10-I-1<br>56<br>1SNA166576R2700<br>FIM20-I<br>56<br>1SNA166577R2000<br>CPT-2<br>55<br>1SNA166578R0100<br>CPC-1<br>55<br>1SNA166589R2500<br>FIC-2/4-I<br>26<br>1SNA166625R2000<br>CC-E-VA-6.6<br>22<br>1SNA166627R2200<br>TC-E-VA-2-2<br>34<br>1SNA166628R0300<br>TC-E-C5A-2.2<br>34<br>1SNA166630R0100<br>PC-E-VA-8.8<br>34<br>1SNA166638R0500<br>COR-C-R1-6.6<br>24<br>1SNA166643R0200<br>COR-C-3<br>24<br>1SNA166644R0300<br>FIT-2/1-2<br>51<br>1SNA166645R0400<br>CPP-2<br>55<br>1SNA166646R0500<br>CPT-1<br>55<br>1SNA166647R0600<br>CPP-1<br>55<br>1SNA166672R0700<br>FIT-2/4-I<br>52<br>1SNA166722R2100<br>CC-S-INF-VL-6.6<br>22<br>1SNA166723R2200<br>TO-S-INF-VL-12.12<br>40<br>1SNA166733R2400<br>CPT-4<br>55<br>1SNA166734R2500<br>CPC-7(1)<br>55<br>1SNA166737R2000<br>CC-E-VA<br>22<br>1SNA166738R0100<br>CC-D-VA<br>22<br>1SNA166741R0400<br>TO-DS-VL<br>40<br>1SNA166742R0500<br>TC-DS-VL<br>34<br>1SNA166743R0600<br>TO-E-VA<br>40<br>1SNA166744R0700<br>TO-D-VA<br>40<br>1SNA166745R0000<br>TF-E-VA<br>46<br>1SNA166746R0100<br>TF-D-VA<br>46<br>1SNA166747R0200<br>TC-E-VA<br>34<br>1SNA166748R1300<br>TC-D-VA<br>34<br>1SNA166757R0400<br>PO-DS-VL<br>40<br>1SNA166758R1500<br>PC-DS-VL<br>34<br>Part Number<br>Type<br>Page|1SNA166759R1600<br>PO-E-VA<br>40<br>1SNA166760R1300<br>PO-D-VA<br>40<br>1SNA166761R0000<br>PF-E-VA<br>46<br>1SNA166762R0100<br>PF-D-VA<br>46<br>1SNA166763R0200<br>PC-E-VA<br>34<br>1SNA166764R0300<br>PC-D-VA<br>34<br>1SNA166772R0300<br>M10-P-C5A<br>56<br>1SNA166774R0500<br>M10-I-C5A-1<br>56<br>1SNA166777R0000<br>M20-I-C5A<br>56<br>1SNA166778R1100<br>COR-C-R2-6.6<br>24<br>1SNA166819R2300<br>FIC-2/1-1<br>26<br>1SNA166821R1500<br>FIT-2/1-1<br>51<br>1SNA166874R2200<br>DEO-D-VA<br>40<br>1SNA166876R2400<br>CPDE-1<br>55<br>1SNA166877R2500<br>FIDE-2/4<br>52<br>1SNA166878R0600<br>DEO-E-VA<br>40<br>1SNA166896R1100<br>DEF-D-VA<br>46<br>1SNA166897R1200<br>FIDE-1/4-D<br>53<br>1SNA166898R2300<br>FIDE-1/4-G<br>52<br>1SNA166925R1500<br>TO-E-VA-12.12<br>40<br>1SNA166926R1600<br>CPDE-2<br>55<br>1SNA166928R2000<br>KEM-1<br>23<br>1SNA166930R2600<br>CPT-5<br>55<br>1SNA166936R1000<br>FIC-2/4-2<br>26<br>1SNA166937R1100<br>FIT-2/4-2<br>51<br>1SNA166939R2300<br>FIP-2/4-2<br>51<br>1SNA166941R2500<br>CC-I-VA-2<br>22<br>1SNA166943R2700<br>FIDE-2/4-2<br>51<br>1SNA166945R2100<br>TO-I-VA-2<br>40<br>1SNA166948R0400<br>TC-S-INF-VL-2.2<br>34<br>1SNA166962R0000<br>KEM-3<br>23<br>1SNA166963R0000<br>CC-TH35-VL-6.6<br>22<br>1SNA166964R0000<br>TC-TH35-VL<br>34<br>1SNA166972R0000<br>TT4-S-VL-INF<br>48<br>1SNA166976R0000<br>CC-E-VA-R2-6.6<br>22<br>1SNA166977R0000<br>TC-E-VA-R2-2.2<br>34<br>1SNA166978R0000<br>COR-P-R1-8.8<br>50<br>1SNA166979R0000<br>COR-C-R3<br>24<br>1SNA166980R0000<br>BRE-T-4<br>54<br>1SNA167002R0000<br>CPT-RJ45<br>14<br>1SNA167008R0300<br>EXBR1<br>26<br>1SNA167260R1700<br>BRE-C-2.5<br>26<br>1SNA167264R0700<br>BRE-C-1<br>26<br>1SNA167265R0000<br>BRE-C-1.5<br>26<br>1SNA167378R1100<br>COP-FI-1<br>58<br>1SNA167379R1200<br>COP-E-1<br>58<br>1SNA167496R1100<br>PCVA<br>23<br>1SNA167622R2600<br>IR1<br>26<br>1SNA167623R2700<br>IR2<br>26<br>1SNA167624R2000<br>IR3<br>26<br>Part Number<br>Type<br>Page|Part Number<br>Type<br>Page|
|---|---|---|
|||1SNA167680R0500<br>BJ-VL<br>23|
|||1SNA167681R2200<br>PCVL<br>23|
|||1SNA167682R2300<br>FX<br>23|
|||1SNA167690R0700<br>FCB-1<br>26|
|||1SNA167692R2500<br>FCB-2<br>26|
|||1SNA167697R2200<br>CA<br>26|
|||1SNA167779R1300<br>BRE-T-0.75<br>54|
|||1SNA167927R1000<br>FC4-1<br>26|
|||1SNA167931R1400<br>FC4-5<br>26|
|||1SNA167932R1500<br>COR-C-R4-6.6<br>24|
|||1SNA167933R1600<br>COR-T-R5-2.2<br>50|
|||1SNA167934R1700<br>COR-C-R5-6.6<br>24|
|||1SNA167935R1000<br>COR-T-4-4<br>50|
|||1SNA167936R1100<br>FI-2/4-DIA4<br>49|
|||1SNA167937R0000<br>FIC-2/4-DIA4<br>25|
|||1SNA167971R2400<br>DLVR<br>26|
|||1SNA167981R1700<br>DI<br>26|
|||1SNA168146R0200<br>BRE-C-6<br>26|
|||1SNA168147R0300<br>BRE-T-6<br>54|
|||1SNA168160R1400<br>BRE-T-0.34<br>54|
|||1SNA173181R1300<br>PSC<br>26|
|||1SNA183436R0500<br>CVABM<br>23|
|||1SNA205876R0400<br>BRE-C-4<br>26|
|||1SNA566000R0000<br>TC-E-RJ45-INF<br>14|
|||1SNA566001R0000<br>FI-RJ45-DIA4<br>14|
||||
**==> picture [73 x 43] intentionally omitted <==**
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
8
## **Index** Type classification
|BJ-VL<br>1SNA167680R0500<br>23<br>BRE-C-1<br>1SNA167264R0700<br>26<br>BRE-C-1.5<br>1SNA167265R0000<br>26<br>BRE-C-2.5<br>1SNA167260R1700<br>26<br>BRE-C-4<br>1SNA205876R0400<br>26<br>BRE-C-6<br>1SNA168146R0200<br>26<br>BRE-T-0.34<br>1SNA168160R1400<br>54<br>BRE-T-0.75<br>1SNA167779R1300<br>54<br>BRE-T-1<br>1SNA164921R1700<br>54<br>BRE-T-1.5<br>1SNA164922R1000<br>54<br>BRE-T-2.5<br>1SNA164923R1100<br>54<br>BRE-T-4<br>1SNA166980R0000<br>54<br>BRE-T-6<br>1SNA168147R0300<br>54<br>CA<br>1SNA167697R2200<br>26<br>CC-D-VA<br>1SNA166738R0100<br>22<br>CC-E-VA<br>1SNA166737R2000<br>22<br>CC-E-VA-6.6<br>1SNA166625R2000<br>22<br>CC-E-VA-R2-6.6<br>1SNA166976R0000<br>22<br>CC-I-VA-2<br>1SNA166941R2500<br>22<br>CC-R-VA<br>1SNA166523R1200<br>22<br>CC-S-INF-VL-6.6<br>1SNA166722R2100<br>22<br>CC-TH35-VL-6.6<br>1SNA166963R0000<br>22<br>COP-E-1<br>1SNA167379R1200<br>58<br>COP-FI-1<br>1SNA167378R1100<br>58<br>COR-C-3<br>1SNA166643R0200<br>24<br>COR-C-R1-6.6<br>1SNA166638R0500<br>24<br>COR-C-R2-6.6<br>1SNA166778R1100<br>24<br>COR-C-R3<br>1SNA166979R0000<br>24<br>COR-C-R4-6.6<br>1SNA167932R1500<br>24<br>COR-C-R5-6.6<br>1SNA167934R1700<br>24<br>COR-P-R1-8.8<br>1SNA166978R0000<br>50<br>COR-T-4-4<br>1SNA167935R1000<br>50<br>COR-T-R5-2.2<br>1SNA167933R1600<br>50<br>CPC-1<br>1SNA166578R0100<br>55<br>CPC-7<br>1SNA166734R2500<br>55<br>CPDE-1<br>1SNA166876R2400<br>55<br>CPDE-2<br>1SNA166926R1600<br>55<br>CPP-1<br>1SNA166647R0600<br>55<br>CPP-2<br>1SNA166645R0400<br>55<br>CPT-1<br>1SNA166646R0500<br>55<br>CPT-2<br>1SNA166577R2000<br>55<br>CPT-4<br>1SNA166733R2400<br>55<br>CPT-5<br>1SNA166930R2600<br>55<br>CPT-RJ45<br>1SNA167002R0000<br>14<br>CVABM<br>1SNA183436R0500<br>23<br>DEF-D-VA<br>1SNA166896R1100<br>46<br>DEO-D-VA<br>1SNA166874R2200<br>40<br>DEO-E-VA<br>1SNA166878R0600<br>40<br>DI<br>1SNA167981R1700<br>26<br>DLVR<br>1SNA167971R2400<br>26<br>Type<br>Part Number<br>Page|EXBR1<br>1SNA167008R0300<br>26<br>FC4-1<br>1SNA167927R1000<br>26<br>FC4-5<br>1SNA167931R1400<br>26<br>FCB-1<br>1SNA167690R0700<br>26<br>FCB-2<br>1SNA167692R2500<br>26<br>FI-2/4-DIA4<br>1SNA167936R1100<br>49<br>FIC-2/1-1<br>1SNA166819R2300<br>26<br>FIC-2/4-1<br>1SNA166525R1400<br>26<br>FIC-2/4-2<br>1SNA166936R1000<br>26<br>FIC-2/4-DIA4<br>1SNA167937R0000<br>25<br>FIC-2/4-I<br>1SNA166589R2500<br>26<br>FIC-2/4-R<br>1SNA166529R2000<br>26<br>FIDE-1/4-D<br>1SNA166897R1200<br>53<br>FIDE-1/4-G<br>1SNA166898R2300<br>52<br>FIDE-2/4<br>1SNA166877R2500<br>52<br>FIDE-2/4-2<br>1SNA166943R2700<br>51<br>FIM10-1<br>1SNA166516R1300<br>56<br>FIM10-I-1<br>1SNA166574R2500<br>56<br>FIM10-R<br>1SNA166573R2400<br>56<br>FIM20-I<br>1SNA166576R2700<br>56<br>FIP-1/4-D<br>1SNA166555R2200<br>53<br>FIP-1/4-G<br>1SNA166556R2300<br>52<br>FIP-2/4-1<br>1SNA166559R0600<br>52<br>FIP-2/4-2<br>1SNA166939R2300<br>51<br>FI-RJ45-DIA4<br>1SNA566001R0000<br>14<br>FIT-1/4-D<br>1SNA166546R2100<br>53<br>FIT-1/4-G<br>1SNA166547R2200<br>52<br>FIT-2/1-1<br>1SNA166821R1500<br>51<br>FIT-2/1-2<br>1SNA166644R0300<br>51<br>FIT-2/4-1<br>1SNA166550R0100<br>52<br>FIT-2/4-2<br>1SNA166937R1100<br>51<br>FIT-2/4-I<br>1SNA166672R0700<br>52<br>FX<br>1SNA167682R2300<br>23<br>IR1<br>1SNA167622R2600<br>26<br>IR2<br>1SNA167623R2700<br>26<br>IR3<br>1SNA167624R2000<br>26<br>KEM-1<br>1SNA166928R2000<br>23<br>KEM-3<br>1SNA166962R0000<br>23<br>M10-D-C5A<br>1SNA166513R1000<br>56<br>M10-I-C5A-1<br>1SNA166774R0500<br>56<br>M10-P-C5A<br>1SNA166772R0300<br>56<br>M10-R-C5A<br>1SNA166566R2500<br>56<br>M20-I-C5A<br>1SNA166777R0000<br>56<br>PC-DS-VL<br>1SNA166758R1500<br>34<br>PC-D-VA<br>1SNA166764R0300<br>34<br>PC-E-VA<br>1SNA166763R0200<br>34<br>PC-E-VA-8.8<br>1SNA166630R0100<br>34<br>PCVA<br>1SNA167496R1100<br>23<br>PCVL<br>1SNA167681R2200<br>23<br>PF-DS-VL<br>1SNA166506R2200<br>46<br>Type<br>Part Number<br>Page|Type<br>Part Number<br>Page|
|---|---|---|
|||PF-D-VA<br>1SNA166762R0100<br>46|
|||PF-E-VA<br>1SNA166761R0000<br>46|
|||PO-DS-VL<br>1SNA166757R0400<br>40|
|||PO-D-VA<br>1SNA166760R1300<br>40|
|||PO-E-VA<br>1SNA166759R1600<br>40|
|||PSC<br>1SNA173181R1300<br>26|
|||TC-DS-VL<br>1SNA166742R0500<br>34|
|||TC-D-VA<br>1SNA166748R1300<br>34|
|||TC-E-C5A-2.2<br>1SNA166628R0300<br>34|
|||TC-E-RJ45-INF<br>1SNA566000R0000<br>14|
|||TC-E-VA<br>1SNA166747R0200<br>34|
|||TC-E-VA-2-2<br>1SNA166627R2200<br>34|
|||TC-E-VA-R2-2.2<br>1SNA166977R0000<br>34|
|||TC-S-INF-VL-2.2<br>1SNA166948R0400<br>34|
|||TC-TH35-VL<br>1SNA166964R0000<br>34|
|||TF-DS-VL<br>1SNA166503R2700<br>46|
|||TF-D-VA<br>1SNA166746R0100<br>46|
|||TF-E-VA<br>1SNA166745R0000<br>46|
|||TO-DS-VL<br>1SNA166741R0400<br>40|
|||TO-D-VA<br>1SNA166744R0700<br>40|
|||TO-E-VA<br>1SNA166743R0600<br>40|
|||TO-E-VA-12.12<br>1SNA166925R1500<br>40|
|||TO-I-VA-2<br>1SNA166945R2100<br>40|
|||TO-S-INF-VL-12.12<br>1SNA166723R2200<br>40|
|||TT4-S-VL-INF<br>1SNA166972R0000<br>48|
||||
**==> picture [73 x 43] intentionally omitted <==**
PAGE 65
## LET’S CONNECT
We make it easy to connect with our experts and are ready to provide all the support you need. For additional information or product assistance, please contact your field representative or our customer service department. Additional information is also available on the website http://www.te.com/entrelec.
## TECHNICAL SUPPORT
te.com/support-center
## Asia:
+86 400-820-6015 Europe, Middle East, & Africa: +49 6251-133-0
North America: +1-888-441-9982
## **te.com**
ENTRELEC, TE Connectivity, TE Connectivity (logo) and Every Connection Counts are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners.
## **TE Connectivity**
All other logos, products and/or company names referred to herein might be trademarks of their respective owners.
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity's obligations shall only be as set forth in TE Connectivity's Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application.
3, rue Jean Perrin 69687 Chassieu cedex France
Tel: +33 472172222
www.te.com/
© 2018 TE Connectivity Ltd. family of companies All Rights Reserved.
**1-1773959-3_EN 02/19**
**==> picture [73 x 43] intentionally omitted <==**
INDUSTRIAL /// ENTRELEC - ESSAILEC[®] TEST BLOCKS
Updated at April 27, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →