1SAM350000R1006
MOTOR STARTER, 3-PH, 0.55KW, 1.6A, 690V
- Manufacturer: ABB
- Product type: Motor Starters
- SVHC: To Be Advised
- No. of Poles: 3 Pole
- Power Rating: 550W
- No. of Phases: Single Phase, Three Phase
- Product Range: MS132
- Current Rating: 1.6A
- IP / NEMA Rating: IP20
- Motor Starter Type: Manual Starter
- Supply Voltage Max: 690VAC
- Supply Voltage Min: 230VAC
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 151.07 € |
| Current stock | 10+ |
| Lead time | 7 days |
PRODUCT-DETAILS ## **MS132-1.6** ## MS132-1.6 Manual Motor Starter |**General Information**|| |---|---| |Extended Product Type|MS132-1.6| |Product ID|1SAM350000R1006| |EAN|4013614400063| |Catalog Description|MS132-1.6 Manual Motor Starter| ||The MS132-1.6 manual motor starter (also known as motor protection circuit breaker| ||or manual motor protector) is a compact 45 mm width device with a rated operational| ||current of Ie = 1.60 A. This device is used to manually switch on and off motors and to| ||protect them reliably and without the need for a fuse from short-circuits, overload and| ||phase failures. The manual motor starter offers a rated service short-circuit breaking| |Long Description|capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in| ||disconnect function, temperature compensation, trip-free mechanism and a rotary| ||handle with a clear switch position indication. The manual motor starter is suitable for| ||three- and single-phase applications. The handle is lockable to protect against| ||unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases,| ||shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.| ## **Ordering** |**Ordering**|| |---|---| |Minimum Order Quantity|1 piece| |Customs Tariff Number|85362010| |**Popular Downloads**|| |Data Sheet, Technical|2CDC131021D0201| |Information|| |Instructions and|2CDC131022M6802| MS132-1.6 2 |Manuals|Manuals||| |---|---|---|---| |Instructions and||2CDC131060M0202|| |Manuals (Part 2)|||| |Time-Current||1SAM300505F0106|| |Characteristic Curve|||| |I²t Characteristic||1SAM300507F0001|| |||1SAM300507F0003|| |Cut-off Current||1SAM300508F0001|| |Characteristic||1SAM300508F0003|| |Dimension Diagram||1SAM300402F0001|| |**Dimensions**|||| |Product Net Width||45 mm|| |Product Net Height||90 mm|| |Product Net Depth /||86.75 mm|| |Length|||| |Product Net Weight||0.265 kg|| |**Technical**|||| ||Rated Service Short-|(230 V AC) 100 kA|| ||Circuit Breaking|(250 V DC) 3 Poles in Series 10 kA|| ||Capacity (Ics)|(400 V AC) 100 kA|| |||(440 V AC) 100 kA|| |||(500 V AC) 100 kA|| |||(690 V AC) 100 kA|| ||Rated Ultimate Short-|(230 V AC) 100 kA|| ||Circuit Breaking|(400 V AC) 100 kA|| ||Capacity (Icu)|(440 V AC) 100 kA|| |||(500 V AC) 100 kA|| |||(690 V AC) 100 kA|| |Rated Instantaneous||20 A|| |Short-Circuit Current|||| |Setting (Ii)|||| |Setting Range||1.0 ... 1.6 A|| |Rated Operational Power||(400 V) Three Phase 0.55 kW|| |AC-3 (Pe)|||| |Rated Operational||Main Circuit 690 V AC|| |Voltage||Main Circuit 250 V DC|| |Rated Operational||1.6 A|| |Current (Ie)|||| |Rated Operational||1.6 A|| |Current AC-3 (Ie)|||| |Rated Operational||1.6 A|| |Current DC-5 (Ie)|||| |Rated Frequency (f)||Main Circuit 50 Hz|| |||Main Circuit 60 Hz|| |Rated Impulse||Main Circuit 6 kV|| |Withstand Voltage (Uimp|||| |)|||| |Rated Insulation Voltage||690 V|| |(Ui)|||| |Power Loss||at Rated Operating Conditions per Pole 0.6 ... 1.7 W|| |Number of Poles||3|| |Conventional Free-air||Main Circuit 1.6 A|| |Thermal Current (Ith)|||| |Degree of Protection||Housing IP20|| |||Main Circuit Terminals IP10|| |Pollution Degree||3|| |Electrical Durability||50000 cycle|| |Mechanical Durability||100000 cycle|| |Terminal Type||Screw Terminals|| ||||| MS132-1.6 3 ||Connecting Capacity|Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²| |---|---|---| ||Main Circuit|Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²| |||Flexible 1/2x 0.75 ... 2.5 mm²| |||Rigid 1/2x 1 ... 4 mm²| |Tightening Torque||Main Circuit 0.8 ... 1.2 N·m| |Wire Stripping Length||Main Circuit 9 mm| |Recommended Screw||Pozidriv 2| |Driver||| |Mounting Position||Position 1 to 6| |Mounting on DIN Rail||TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715| |||TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715| |Minimum Mounting||Electrical Conductive Board, Horizontal - Up to 400 V 0 mm| |Distance||Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm| |||Electrical Conductive Board, Vertical 75 mm| |||Other Device Same Type, Horizontal 0 mm| |||Other Device Same Type, Vertical 150 mm| |Actuator Type||Rotary Handle| |Contact Position||ON / OFF / TRIP| |Indication||| |Standards||IEC/EN 60947-1| |||IEC/EN 60947-2| |||IEC/EN 60947-4-1| |||UL 60947-1| |||UL 60947-4-1| ||Remarks|UL508 Self-Protected Combination Motor Controller (Type E) in| |||combination with feeder block S1-M3-xx| |**Technical UL/CSA**||| ||Short-Circuit Current|Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC)| ||Rating (SCCR)|65 kA| |||Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC)| |||47 kA| |||Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65| |||kA| |||Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47| |||kA| |||Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65| |||kA| |||Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47| |||kA| |||Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in| |||Group Installations (480 V AC) 65 kA| |||Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in| |||Group Installations (600 V AC) 47 kA| |Maximum Operating||Main Circuit 600 V AC| |Voltage UL/CSA||| |Ampere Rating UL/CSA||1.6 A| |Horsepower Rating||(440 ... 480 V AC) Three Phase 0.75 Hp| |UL/CSA||(550 ... 600 V AC) Three Phase 0.75 Hp| |Full Load Amps Motor||(200 V AC) Three Phase 1.6 A| |Use||(208 V AC) Three Phase 1.6 A| |||(220 ... 240 V AC) Three Phase 1.6 A| |||(440 ... 480 V AC) Three Phase 1.6 A| |Locked Rotor Amps||(200 V AC) Three Phase 9.6 A| |||(208 V AC) Three Phase 9.6 A| |||(220 ... 240 V AC) Three Phase 9.6 A| |||(440 ... 480 V AC) Three Phase 9.6 A| |||(550 ... 600 V AC) Three Phase 9.6 A| |General Use Rating||(600 V AC) 1.6 A| |UL/CSA||| |Connecting Capacity||Flexible 1/2x 16-12 AWG| |Main Circuit UL/CSA||Stranded 1/2x 16-12 AWG| |Tightening Torque||Main Circuit 10 ... 12 in·lb| |UL/CSA||| |||| MS132-1.6 4 |**Environmental**||| |---|---|---| |Ambient Air|Around the Enclosure 0 ... +40 °C|| |Temperature|Operation -25 ... +70 °C|| ||Operation Compensated -25 ... +60 °C|| ||Storage -50 ... +80 °C|| |Ambient Air|Yes|| |Temperature||| |Compensation||| |Maximum Operating|2000 m|| |Altitude Permissible||| |Resistance to Shock acc.|11 ms Pulse 25g|| |to IEC 60068-2-27||| |Resistance to Vibrations|5g / 3 ... 150 Hz|| |acc. to IEC 60068-2-6||| |RoHS Status|Following EU Directive 2011/65/EU|| ## **Certificates and Declarations (Document Number)** ||ABS Certificate|1SAA963001-0101|| |---|---|---|---| ||ATEX Certificate|1SAA963000-3902|| ||BV Certificate|1SAA963001-0202|| ||CB Certificate|1SAA963002-2002|| ||CCC Certificate|1SAA963001-3805|| ||cUL Certificate|cUL_E137861|| |||cUL_E345003|| ||cULus Certificate|cUL_E137861|| |Cut-off Current||1SAM300508F0001|| |Characteristic||1SAM300508F0003|| ||Declaration of|1SAD938514-0125|| ||Conformity - CE||| ||DNV GL Certificate|1SAA963001-0304|| ||EAC Certificate|1SAA963000-2701|| ||GOST Certificate|1SAA963001-2702|| ||I²t Characteristic|1SAM300507F0001|| |||1SAM300507F0003|| ||Instructions and|2CDC131022M6802|| ||Manuals||| ||Instructions and|2CDC131060M0202|| ||Manuals (Part 2)||| ||LR Certificate|1SAA963001-0502|| ||RINA Certificate|Rina_MS132|| ||RMRS Certificate|1SAA918000-0704|| ||RoHS Information|1SAD938511-0125|| ||Time-Current|1SAM300505F0106|| ||Characteristic Curve||| ||UL Certificate|UL_E137861|| |||UL_E345003|| |RoHS Information<br>Time-Current<br>Characteristic Curve<br>UL Certificate|1SAD938511-0125<br>1SAM300505F0106<br>UL_E137861<br>UL_E345003|| |---|---|---| |**Container Information**||| |Package Level 1 Units|box 1 piece|| |Package Level 1 Width|92 mm|| |Package Level 1 Depth /|95 mm|| |Length||| |Package Level 1 Height|50 mm|| |Package Level 1 Gross|0.28 kg|| |Weight||| |Package Level 1 EAN|4013614400063|| |Package Level 2 Units|carton 40 piece|| |Package Level 2 Width|280 mm|| MS132-1.6 5 |Package Level|2|Depth /|395 mm|| |---|---|---|---|---| |Length||||| |Package Level|2|Height|210 mm|| |Package Level|2|Gross|11.586 kg|| |Weight||||| |Package Level|2|EAN|4013614408960|| ## **Classifications** |**Classifications**|| |---|---| |Object Classification|F| |Code|| |ETIM 4|EC000074 - Motor protective circuit-breaker| |ETIM 5|EC000074 - Motor protective circuit-breaker| |ETIM 6|EC000074 - Motor protection circuit-breaker| |ETIM 7|EC000074 - Motor protection circuit-breaker| |eClass|7.0 27370401| |UNSPSC|39121521| |IDEA Granular Category|4845 >> 3 Pole Motor Circuit Protector Circuit Breakers| |Code (IGCC)|| |E-Number (Sweden)|3112122| ## **Accessories** |**Accessories**||||| |---|---|---|---|---| |**Identifier**|**Description**|**Type**|**Quantity**|**Unit Of**<br>**Measure**| |1SAM101923R0002|MSMN Driver|MSMN|1|piece| |1SAM101923R0012|MSMNO Driver|MSMNO|1|piece| |1SAM101924R0003|MSOX-32 Driver Shaft|MSOX-32|1|piece| |1SAM101924R0013|MSOX-30 Driver Shaft|MSOX-30|1|piece| |1SAM201901R1001|HKF1-11 Auxiliary Contact|HKF1-11|1|piece| |1SAM201901R1002|HKF1-20 Auxiliary Contact|HKF1-20|1|piece| |1SAM201901R1003|HKF1-10 Auxiliary Contact|HKF1-10|1|piece| |1SAM201901R1004|HKF1-01 Auxiliary Contact|HKF1-01|1|piece| |1SAM201901R1201|HKF1-11K Auxiliary Contact|HKF1-11K|1|piece| |1SAM201901R1202|HKF1-20K Auxiliary Contact|HKF1-20K|1|piece| |1SAM201902R1001|HK1-11 Auxiliary Contact|HK1-11|1|piece| |1SAM201902R1002|HK1-20 Auxiliary Contact|HK1-20|1|piece| |1SAM201902R1003|HK1-02 Auxiliary Contact|HK1-02|1|piece| |1SAM201902R1004|HK1-20L Auxiliary Contact|HK1-20L|1|piece| |1SAM201902R1201|HK1-11K Auxiliary Contact|HK1-11K|1|piece| |1SAM201902R1202|HK1-20K Auxiliary Contact|HK1-20K|1|piece| |1SAM201902R1203|HK1-02K Auxiliary Contact|HK1-02K|1|piece| |1SAM201902R1204|HK1-20LK Auxiliary Contact|HK1-20LK|1|piece| |1SAM201903R1001|SK1-11 Signal Contact|SK1-11|1|piece| |1SAM201903R1002|SK1-20 Signal Contact|SK1-20|1|piece| |1SAM201903R1003|SK1-02 Signal Contact|SK1-02|1|piece| |1SAM201903R1201|SK1-11K Signal Contact|SK1-11K|1|piece| |1SAM201903R1202|SK1-20K Signal Contact|SK1-20K|1|piece| |1SAM201903R1203|SK1-02K Signal Contact|SK1-02K|1|piece| |1SAM201904R1001|UA1-24 Undervoltage Release|UA1-24|1|piece| |1SAM201904R1002|UA1-48 Undervoltage Release|UA1-48|1|piece| |1SAM201904R1003|UA1-60 Undervoltage Release|UA1-60|1|piece| |1SAM201904R1004|UA1-110 Undervoltage Release|UA1-110|1|piece| |1SAM201904R1005|UA1-230 Undervoltage Release|UA1-230|1|piece| |1SAM201904R1006|UA1-400 Undervoltage Release|UA1-400|1|piece| |1SAM201904R1007|UA1-415 Undervoltage Release|UA1-415|1|piece| |1SAM201904R1008|UA1-208 Undervoltage Release|UA1-208|1|piece| MS132-1.6 6 |1SAM201904R1009|UA1-575 Undervoltage Release|UA1-575|1|piece| |---|---|---|---|---| |1SAM201904R1010|UA1-20 Undervoltage Release|UA1-20|1|piece| |1SAM201906R1102|PS1-2-0-65 Busbar|PS1-2-0-65|1|piece| |1SAM201906R1103|PS1-3-0-65 Busbar|PS1-3-0-65|1|piece| |1SAM201906R1104|PS1-4-0-65 Busbar|PS1-4-0-65|1|piece| |1SAM201906R1105|PS1-5-0-65 Busbar|PS1-5-0-65|1|piece| |1SAM201906R1112|PS1-2-1-65 Busbar|PS1-2-1-65|1|piece| |1SAM201906R1113|PS1-3-1-65 Busbar|PS1-3-1-65|1|piece| |1SAM201906R1114|PS1-4-1-65 Busbar|PS1-4-1-65|1|piece| |1SAM201906R1115|PS1-5-1-65 Busbar|PS1-5-1-65|1|piece| |1SAM201906R1122|PS1-2-2-65 Busbar|PS1-2-2-65|1|piece| |1SAM201906R1123|PS1-3-2-65 Busbar|PS1-3-2-65|1|piece| |1SAM201906R1124|PS1-4-2-65 Busbar|PS1-4-2-65|1|piece| |1SAM201906R1125|PS1-5-2-65 Busbar|PS1-5-2-65|1|piece| |1SAM201907R1101|S1-M1-25 Power Infeed Block|S1-M1-25|1|piece| |1SAM201907R1102|S1-M2-25 Power Infeed Block|S1-M2-25|1|piece| |1SAM201907R1103|S1-M3-25 Power Infeed Block|S1-M3-25|1|piece| |1SAM201908R1001|BS1-3 Protection Cover|BS1-3|1|piece| |1SAM201909R1001|FS116 Screw Fixing Kit|FS116|1|piece| |1SAM201909R1021|MSAH1 Shaft Supporter|MSAH1|1|piece| |1SAM201910R1001|AA1-24 Shunt Trip|AA1-24|1|piece| |1SAM201910R1002|AA1-110 Shunt Trip|AA1-110|1|piece| |1SAM201910R1003|AA1-230 Shunt Trip|AA1-230|1|piece| |1SAM201910R1004|AA1-400 Shunt Trip|AA1-400|1|piece| |1SAM201911R1010|IB132-G Enclosure|IB132-G|1|piece| |1SAM201911R1011|IB132-Y Enclosure|IB132-Y|1|piece| |1SAM201911R1012|IB132-F Enclosure|IB132-F|1|piece| |1SAM201912R1010|DMS132-G Door Mounting Kit|DMS132-G|1|piece| |1SAM201912R1011|DMS132-Y Door Mounting Kit|DMS132-Y|1|piece| |1SAM201913R1103|S1-M3-35 Power Infeed Block|S1-M3-35|1|piece| |1SAM201914R1001|PB1-1-32 Connecting Link|PB1-1-32|1|piece| |1SAM201914R1002|S1-PB1-25 Power Infeed Block|S1-PB1-25|1|piece| |1SAM201916R1103|PS1-3-0-100 Busbar|PS1-3-0-100|1|piece| |1SAM201916R1104|PS1-4-0-100 Busbar|PS1-4-0-100|1|piece| |1SAM201916R1105|PS1-5-0-100 Busbar|PS1-5-0-100|1|piece| |1SAM201916R1113|PS1-3-1-100 Busbar|PS1-3-1-100|1|piece| |1SAM201916R1114|PS1-4-1-100 Busbar|PS1-4-1-100|1|piece| |1SAM201916R1115|PS1-5-1-100 Busbar|PS1-5-1-100|1|piece| |1SAM201916R1123|PS1-3-2-100 Busbar|PS1-3-2-100|1|piece| |1SAM201920R1000|MSH-AR Shaft Alignment Ring|MSH-AR|1|piece| |1SAM201920R1011|MSHD-LTB Handles|MSHD-LTB|1|piece| |1SAM201920R1012|MSHD-LTY Handles|MSHD-LTY|1|piece| |1SAM301901R1001|CK1-11 Short Circuit Signaling Contact|CK1-11|1|piece| |1SAM301901R1002|CK1-20 Short Circuit Signaling Contact|CK1-20|1|piece| |1SAM301901R1003|CK1-02 Short Circuit Signaling Contact|CK1-02|1|piece| |1SCA101647R1001|OXS6X85 SHAFT|OXS6X85|1|piece| |1SCA101655R1001|OXS6X130 SHAFT|OXS6X130|1|piece| |1SCA101659R1001|OXS6X180 SHAFT|OXS6X180|1|piece| |1SCA108043R1001|OXS6X105 SHAFT|OXS6X105|1|piece| |GJF1101903R0002|SA2 - Terminals and Installation Material|SA2|1|piece| **Categories** MS132-1.6 7 Low Voltage Products and Systems → Circuit Breakers → Manual Motor Starters Low Voltage Products and Systems → Control Products → Manual Motor Starters → Manual Motor Starters
Updated at March 17, 2026
ABB is a global leader in power and automation technologies, recognized for delivering innovative solutions that improve performance while minimizing environmental impact. Serving a diverse range of sectors including industrial processing, OEM, and building services, ABB provides highly reliable components designed to meet the rigorous demands of modern electrical systems. The company is particularly renowned for its advanced circuit protection solutions. This includes a comprehensive selection of thermal magnetic circuit breakers, alongside specialized RCBO, RCD, GFCI, and AFDD circuit breakers. These foundational safety components are supported by a wide array of high-quality fuse holders and circuit breaker accessories, ensuring complete protection for complex industrial and commercial installations. Beyond circuit protection, ABB excels in automation and process control. Their offering features sophisticated visual signal indicator units, industrial switch accessories, and panel instrumentation designed for intuitive system monitoring. Additionally, ABB manufactures a robust range of power relays, safety relays, and AC/DC converters, providing engineers with the critical building blocks needed for efficient, secure, and reliable control panels.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →