Image not available
Illustrative purposes only
199AX-4
RELAY, SPDT, 300VAC, 28VDC, 40A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SCHNEIDER ELECTRIC/LEGACY RELAY
- Product type: Power Relays
- Coil Voltage: 120VAC
- Product Range: W199 Series
- Relay Mounting: Panel Mount
- Coil Resistance: 290ohm
- Contact Current: 40A
- Relay Terminals: Screw
- Contact Material: Silver Tin Oxide
- Contact Voltage VAC: 300VAC
- Contact Voltage VDC: 28VDC
- Contact Configuration: SPDT
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 79.02 € |
| Current stock | 10+ |
| Lead time | 30 days |
## Advantages of the W199 Power Relay The Magnecraft 199 relay is the powerhouse open relay. Standard parts can handle up to 40A and there are options to handle up to 50A. The device is available in a variety of configurations and coil voltages. Available with up to two poles, double and single throws, insulated and noninsulated double make and/or break, and several switching forms. Options include auxiliary 10A switches with quick connects or screw terminals, quick connects on the coils and/or contacts, tungsten stationary contacts, fine silver contacts, pressure wire connectors on the output terminals and blowout magnets near the contacts for high voltage DC switching. **==> picture [65 x 29] intentionally omitted <==** **----- Start of picture text -----**<br> Optional Cover<br>(50-1289-1)<br>See Section 3 p.22<br>**----- End of picture text -----**<br> **==> picture [227 x 434] intentionally omitted <==** **----- Start of picture text -----**<br> ‘ “aq] - or<br>Blowout<br>Magnet for<br>High DC<br>Switching W199ADBX-4<br>40Amp<br>Blowout oh<br>Magnet for Auxiliary Switch<br>High DC<br>Switching<br>W199ABMX-7<br>40Amp<br>Blowout<br>Magnet for<br>High DC<br>W199BX-110<br>Switching “<br>40Amp<br>~< al =<br>W199X-8<br>40Amp<br>**----- End of picture text -----**<br> - Available Blowout Magnets for High DC Switching. - Available Auxiliary Switches. - Can be configured with 0.25 inch Q.C. Connections. - Up to 50A Switching. - Available Metal Enclosure. **==> picture [230 x 177] intentionally omitted <==** **----- Start of picture text -----**<br> Shoulder Rivet<br>Pressure Wire<br>Connectors for and Spring<br>Optimize<br>Heavy Gauge<br>Wires Contact Wipe<br>.<br>W199DEX-3<br>50Amp W199DX-2<br>40Amp<br>**----- End of picture text -----**<br> 6/2 Magnecraft Solution Guide 105A 14 AWG for 40A, 11 AWG for 50A Configurations For Superior Load Handling. Combo-Head Screws For Simpler Hook-Up. Wide Array of Options & Configurations For Specific Control Needs. Auxiliary Switch Wide Selection of Coil Voltages To Fit Most Applications. Riveted Construction To Sustain Years of Use. W199AX-14 40Amp W199MX-27 40Amp 1/4 Inch Q.C. on Auxiliary Switch for Speedier Hook-Up 11 AWG Pigtails for 50A Load Switching Auxiliary Switch **==> picture [43 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> W199X-11<br>40Amp<br>**----- End of picture text -----**<br> **==> picture [59 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> 199PQMKKX-1<br>50Amp<br>**----- End of picture text -----**<br> 1/4 Q.C. on Coil for Simpler Installation **==> picture [50 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> W199MX-51<br>40Amp<br>**----- End of picture text -----**<br> W199X-3 40Amp 6/3 Magnecraft Solution Guide 105A |W199 Open Style Power Relay/|W199 Open Style Power Relay/Single and Two Pole 40 and 50 Amp Rating (DC and AC)|W199 Open Style Power Relay/Single and Two Pole 40 and 50 Amp Rating (DC and AC)|Single and Two Pole 40 and 50 Amp Rating (DC and AC)|Single and Two Pole 40 and 50 Amp Rating (DC and AC)|Single and Two Pole 40 and 50 Amp Rating (DC and AC)|Single and Two Pole 40 and 50 Amp Rating (DC and AC)|Single and Two Pole 40 and 50 Amp Rating (DC and AC)|Single and Two Pole 40 and 50 Amp Rating (DC and AC)| |---|---|---|---|---|---|---|---|---| ||||||Combo-Head Screws|||| |UL Recognized<br>File No. E43641<br>UL US<br>C<br>:<br>;<br>TT|Riveted<br>Construction<br>Wide Selection of Coil Voltages<br>14 AWG for 40A, 11 AWG<br>for 50A Configurations<br> &|||||||Wide Selection of Coil Voltages<br>Wide Array of Options<br>and Configurations| |**General Specifications**||(UL 508)||||||| |Contact Characteristics||||Units||||199, 199A| |Number and type of Contacts|Number and type of Contacts|||||SPST, SPDT, DPST, DPDT||SPST, SPDT, DPST, DPDT| |Contact materials||||||||Silver Alloy| |Thermal (Carrying) Current rating||||A||||40| |Maximum Switching Voltage|Maximum Switching Voltage|||V||||600V| |Switching Current @ Voltage|Switching Current @ Voltage||~~~~~|Resistive||40A @ 277V 50/60Hz,||| |||||||5A @ 600VAC 50/60Hz|5A @ 600VAC 50/60Hz|| |||||Resistive||40A @ 28VDC||| |||Blowout magnet||Resistive||_See table A below_||| |||||HP||1 1/2 @ 120-600 VAC||| |||||Tungsten||15A @ 120VAC||| |||||Pilot Duty||||A600| |Minimum Switching Requirement||Minimum||mA||100 @ 12 VAC/VDC||100 @ 12 VAC/VDC| |Coil Characteristics||||||||| |Voltage Range|||~|V||||6….600| |||% of Nominal||V||||6….600| |Operating Range|||~~~~~||||85% to 110%|| ||||||||80% to 110%|| |Average consumption|||~~~~~|VA||||10| |||||W||||4| |Drop-out voltage threshold|||~~~~~|||||10%| |||||||||10%| |Performance Characteristics||||||||| |Electrical Life (UL 508)||Operations @ Rated Current||(Resistive)||||6,000| |Operating time (response time)||||ms||||30| |Dielectric||Between coil and contact|~~~~~|V||||2200| |Environment<br>Product certifications<br>Ambient air temperature||Between poles<br>Between contacts<br>Standard version<br>Storage|~~~~~~|V<br>V<br>°C||||2200<br>1500<br>UL, CSA, CE<br>-40…+85| |around the device||Operation||°C||||-40…+55| |Connection||||AWG (mm2)||||8 (10)| |Terminal Tightening Torque||||in-lb (Nm)||7….9 (0.8….1.0)||| |Weight||||grams||||227 to 312| ## Table A: |Table A:|Table A:|Table A:| |---|---|---| |Additional DC Rating with Magnetic Blowout<br>Single Make/Break<br>Double Make/Break<br>110VDC<br>10 A<br>20 A||| |144VDC|-----|15 A| |220VDC|4 A|8 A| |325VDC|2 A|4 A| |500VDC|-----|2 A| 6/4 Magnecraft Solution Guide 105A www.magnecraft.com 847-441-2540 |Optional Cover<br>(50-1289-1)<br>See Section 3 p.22<br>199D, 199DY, 199AD, 199ADY<br>SPST-DM, SPST-DB<br>Silver Alloy<br>40<br>600V<br>199P, 199AP<br>SPST, SPDT, DPST, DPDT<br>Silver Alloy<br>50<br>600V<br>199DE, 199DYE, 199ADE, 199ADYE<br>SPST-DM, SPST-DB<br>Silver Alloy<br>50<br>600V<br>~~z=~~|Optional Cover<br>(50-1289-1)<br>See Section 3 p.22<br>199D, 199DY, 199AD, 199ADY<br>SPST-DM, SPST-DB<br>Silver Alloy<br>40<br>600V<br>199P, 199AP<br>SPST, SPDT, DPST, DPDT<br>Silver Alloy<br>50<br>600V<br>199DE, 199DYE, 199ADE, 199ADYE<br>SPST-DM, SPST-DB<br>Silver Alloy<br>50<br>600V<br>~~z=~~|Optional Cover<br>(50-1289-1)<br>See Section 3 p.22<br>199D, 199DY, 199AD, 199ADY<br>SPST-DM, SPST-DB<br>Silver Alloy<br>40<br>600V<br>199P, 199AP<br>SPST, SPDT, DPST, DPDT<br>Silver Alloy<br>50<br>600V<br>199DE, 199DYE, 199ADE, 199ADYE<br>SPST-DM, SPST-DB<br>Silver Alloy<br>50<br>600V<br>~~z=~~| |---|---|---| |40A @ 277V 50/60Hz,|50A @ 277V 50/60Hz,|50A @ 277V 50/60Hz,| |10A @ 600VAC 50/60Hz|5A @ 600VAC 50/60Hz|10A @ 600VAC 50/60Hz| |40A @ 28VDC|50A @ 28VDC|50A @ 28VDC| |_See table A below_|_See table A below_|_See table A below_| |2 @ 120-600 VAC|1 1/2 @ 120-600 VAC|2 @ 120-600 VAC| |15A @ 120VAC|15A @ 120VAC|15A @ 120VAC| |A600|A600|A600| |100 @ 12 VAC/VDC|100 @ 12 VAC/VDC|100 @ 12 VAC/VDC| |6….600|6….600|6….600| |6….600|6….600|6….600| |85% to 110%|85% to 110%|85% to 110%| |80% to 110%|80% to 110%|80% to 110%| |10|10|10| |4|4|4| |10%|10%|10%| |10%|10%|10%| |6,000|6,000|6,000| |30|30|30| |2200|2200|2200| |2200|2200|2200| |1500|1500|1500| |UL, CSA, CE|UL, CSA, CE|UL, CSA, CE| |-40…+85|-40…+85|-40…+85| |-40…+55|-40…+55|-40…+55| |8 (10)|8 (10)|8 (10)| |7….9 (0.8….1.0)|7….9 (0.8….1.0)|7….9 (0.8….1.0)| |227 to 312|227 to 312|227 to 312| Table B: |Auxiliary Switch Ratings<br>SPDT<br>DPDT<br>Upto 240VAC 50/60Hz<br>10 A(AC1)<br>10 A(AC1)|Auxiliary Switch Ratings<br>SPDT<br>DPDT<br>Upto 240VAC 50/60Hz<br>10 A(AC1)<br>10 A(AC1)|Auxiliary Switch Ratings<br>SPDT<br>DPDT<br>Upto 240VAC 50/60Hz<br>10 A(AC1)<br>10 A(AC1)| |---|---|---| |Motor Load,120-240VAC 50/60Hz|1/4 HP|1/4 HP| |Pilot Duty,120-240VAC 50/60Hz|278VA|278VA| |125VDC|0.4 A(DC1)|0.4 A(DC1)| |250VDC|0.2 A(DC1)|0.2 A(DC1)| |Tungsten,120VAC 50/60Hz|3 A|3 A| 6/5 Magnecraft Solution Guide 105A |W199 Open Style Power Relay/|W199 Open Style Power Relay/|W199 Open Style Power Relay/Single and Two Pole 40 and 50 Amp Rating (DC and AC)|W199 Open Style Power Relay/Single and Two Pole 40 and 50 Amp Rating (DC and AC)|Single and Two Pole 40 and 50 Amp Rating (DC and AC)|Single and Two Pole 40 and 50 Amp Rating (DC and AC)|Single and Two Pole 40 and 50 Amp Rating (DC and AC)|Single and Two Pole 40 and 50 Amp Rating (DC and AC)|Single and Two Pole 40 and 50 Amp Rating (DC and AC)|Single and Two Pole 40 and 50 Amp Rating (DC and AC)_continued_| |---|---|---|---|---|---|---|---|---|---| ||||||Combo-Head Screws||||| |UL Recognized<br>File No. E43641<br>UL US<br>C<br>:<br>;<br>TT||Riveted<br>Construction<br>Wide Selection of Coil Voltages<br>14 AWG for 40A, 11 AWG<br>for 50A Configurations<br> &||||Wide Selection of Coil Voltages<br>Wide Array of Options<br>and Configurations|||| |**Standard Part Numbers**|||||**BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED**||||**BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED**| |||Nominal Input Voltage|Coil Resistance (OHMS)|Part Number|Contact Configuration||Equipped Optional Features||| |40A Rated Relays, AC Operated|40A Rated Relays, AC Operated|40A Rated Relays, AC Operated|||||||| |||24 VAC 50/60 Hz|12 Ω|**W199AX-3**|SPDT||||| |||120 VAC 50/60 Hz|290 Ω|**W199AX-4**|SPDT||||| |||24 VAC 50/60 Hz|12 Ω|**W199AX-13**|DPDT||||| |||120 VAC 50/60 Hz|290 Ω|**W199AX-14**|DPDT||||| |||240 VAC 50/60 Hz|1200 Ω|**W199AX-15**|DPDT||||| |||24 VAC 50/60 Hz|12 Ω|**W199AX-8**|DPST-NO||||| |||120 VAC 50/60 Hz|290 Ω|**W199AX-9**|DPST-NO||||| |||240 VAC 50/60 Hz|1200 Ω|**W199AX-10**|DPST-NO||||| |||120 VAC 50/60 Hz|290 Ω|**W199ADX-4**|SPST-NO-DM||||| |||240 VAC 50/60 Hz|1200 Ω|W199ADX-5|SPST-NO-DM||||| |||120 VAC 50/60 Hz|290 Ω|**W199ADBX-4**|SPST-NO-DM|||Magnetic Blowout|| |||120 VAC 50/60 Hz|290 Ω|**W199ABX-14**|DPDT|||Magnetic Blowout|| |||120 VAC 50/60 Hz|290 Ω|W199ABMX-7|DPDT||Auxiliary Switch, Magnetic Blowout||Auxiliary Switch, Magnetic Blowout| |||120 VAC 50/60 Hz|290 Ω|**W199AMX-64**|DPDT||||Auxiliary Switch| |||40A Rated Relays, DC Operated|||||||| |||12 VDC|70 Ω|**W199X-2**|SPDT||||| |||24 VDC|290 Ω|**W199X-3**|SPDT||||| |||6 VDC|18 Ω|**W199X-11**|DPDT||||| |||12 VDC|70 Ω|**W199X-12**|DPDT||||| |||24 VDC|290 Ω|**W199X-13**|DPDT||||| |||110 VDC|6000 Ω|**W199X-14**|DPDT||||| |||12 VDC|70 Ω|**W199X-7**|DPST-NO||||| |||24 VDC|290 Ω|**W199X-8**|DPST-NO||||| |||12 VDC|70 Ω|W199DYX-2|SPST-NC-DB||||| |||12 VDC|70 Ω|**W199DX-2**|SPST-NO-DM||||| |||24 VDC<br>24 VDC<br>48 VDC<br>24 VDC<br>110 VDC<br>24 VDC<br>24 VDC|290 Ω<br>290 Ω<br>1200 Ω<br>290 Ω<br>6000 Ω<br>290 Ω<br>290 Ω|**W199DX-3**<br>W199DBX-3<br>W199DBX-6<br>**W199BX-13**<br>**W199BX-14**<br>W199BMX-13<br>W199MX-51|SPST-NO-DM<br>SPST-NO-DM<br>SPST-NO-DM<br>DPDT<br>DPDT<br>DPDT<br>DPDT||Magnetic Blowout<br>Magnetic Blowout<br>Magnetic Blowout<br>Magnetic Blowout<br>Auxiliary Switch, Magnetic Blowout<br>Auxiliary Switch||| |||50A Rated Relays|||||||| |||24 VAC 50/60 Hz|8 Ω|W199APX-13|DPDT||||| |||120 VAC 50/60 Hz|260 Ω|W199APX-14|DPDT||||| |||240 VAC 50/60 Hz|1040 Ω|W199APX-15|DPDT||||| |||120 VAC 50/60 Hz|290 Ω|W199ADEX-4|SPST-NO-DM||Pressure Wire Connectors||| |||6 VDC|18 Ω|199PX-11|DPDT||||| |||12 VDC|70 Ω|W199PX-12|DPDT||||| |||24 VDC|260 Ω|W199PX-13|DPDT||||| |||110 VDC|6000 Ω|199PX-14|DPDT||||| |||24 VDC|290 Ω|W199DEX-3|SPST-NO-DM||Pressure Wire Connectors||| |||110 VDC|6000 Ω|199PQMKKX-1|DPDT||1/4” QC Term. On Coil,||| ||||||||||Auxiliary Switch| *Contact Magnecraft for more configurations to fit your applications. 6/6 Magnecraft Solution Guide 105A www.magnecraft.com 847-441-2540 **==> picture [65 x 29] intentionally omitted <==** **----- Start of picture text -----**<br> Optional Cover<br>(50-1289-1)<br>See Section 3 p.22<br>**----- End of picture text -----**<br> **==> picture [430 x 104] intentionally omitted <==** **----- Start of picture text -----**<br> 2.31 MAX<br>(58.67)<br>1.87 1.62<br>DPDT (47.5) 0.375 (41.14) DPDT<br>2.5 MAX (9.5) 3.12 MAX<br>(63.5) (79.2)<br>**----- End of picture text -----**<br> **==> picture [264 x 104] intentionally omitted <==** **----- Start of picture text -----**<br> 2.25 MAX<br>(57.15)<br>1.87 1.62<br>(47.5) 0.375 (41.14)<br>(9.5)<br>2.5 MAX 2.43 MAX<br>a (63.5) (61.7)<br>**----- End of picture text -----**<br> DPST-NO 6/7 Magnecraft Solution Guide 105A ## W199 Open Style Power Relay/Single and Two Pole 40 and 50 Amp Rating (DC and AC) _continued_ **==> picture [467 x 407] intentionally omitted <==** **----- Start of picture text -----**<br> 2.25 MAX<br>(57.15)<br>DPST-NO w/Blowout Magnet<br>1.87 1.62<br>(47.5) 0.375 (41.14)<br>(9.5)<br>2.5 MAX 2.43 MAX<br>(63.5) (61.7)<br>ere d<br>2.31 MAX<br>(58.67)<br>AO=FI N,<br>DPDT w/Auxiliary Switch and QC<br>Connectors on Coil<br>1.87 1.62<br>AUXILIARY<br>SWITCH _ A (47.5) e 0.375 e (41.14)<br>(9.5)<br>2.5 MAX 3.12 MAX<br>Pie (63.5) (79.2)<br>**----- End of picture text -----**<br> *More configurations available. 6/8 Magnecraft Solution Guide 105A www.magnecraft.com 847-441-2540 **==> picture [380 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> 2.18 MAX<br>(55.37)<br>1.87 1.62<br>(47.5) 0.375 (41.14)<br>(9.5) 2.43 MAX<br>DOUBLEMAKE 2.5 MAX(63.5) (61.7)<br>3.5 MAX<br>P t<br>(88.87)<br>**----- End of picture text -----**<br> SPST-NO-DM w/Pressure Wire Connectors **==> picture [384 x 103] intentionally omitted <==** **----- Start of picture text -----**<br> 2.18 MAX<br>(55.37)<br>1.87 1.62<br>(47.5) 0.375 (41.14) DOUBLE<br>(9.5) MAKE<br>2.5 MAX 2.43 MAX<br>Pat (63.5) (61.7)<br>**----- End of picture text -----**<br> SPST-NO-DM *More configurations available. 6/9 Magnecraft Solution Guide 105A ## W199 Open Style Power Relay/Single and Two Pole 40 and 50 Amp Rating (DC and AC) _continued_ **==> picture [483 x 442] intentionally omitted <==** **----- Start of picture text -----**<br> 2.31 MAX<br>(58.67)<br>DPST-NO w/Auxiliary Switch 1.87 1.62<br>(47.5) 0.375 (41.14)<br>AUXILIARY 2.5 MAX (9.5) 2.43 MAX<br>SWITCH al [1] a [H] i n<br>(63.5) (61.7)<br>—q Fi TL=<br>2.53<br>(64.26)<br>DPDT w/Blowout Magnet<br>and Auxiliary Switch<br>1.87 1.62<br>AUXILIARY a (47.5) ee 0.375 (41.14)<br>SWITCH 2.5 MAX (9.5) 3.12 MAX<br>(63.5) (79.2)<br>fee g re a ob<br>**----- End of picture text -----**<br> *More configurations available. 6/10 Magnecraft Solution Guide 105A www.magnecraft.com 847-441-2540 ) **==> picture [451 x 391] intentionally omitted <==** **----- Start of picture text -----**<br> 2.31 MAX<br>(58.67)<br>SPST-NO-DM w/Blowout Magnet<br>1.87 1.62<br>(47.5) 0.375 (41.14)<br>DOUBLE<br>MAKE 2.5 MAX (9.5) 2.548<br>(63.5) (64.71)<br>— cin =<br>2.31 MAX<br>(58.67)<br>DPDT w/Auxiliary Switch<br>1.87 1.62<br>AUXILIARY<br>C (47.5) h 0.375 FI (41.14) N SWITCH<br>2.5 MAX (9.5) 3.12 MAX<br>(63.5) ca (79.2) e<br>oS<br>**----- End of picture text -----**<br> DPDT w/Auxiliary Switch AUXILIARY SWITCH | **==> picture [371 x 100] intentionally omitted <==** **----- Start of picture text -----**<br> 2.18 MAX<br>(55.37)<br>SPDT<br>e 1.87 e 0.375 1.62<br>(47.5) (9.5) (41.14)<br>2.5 MAX 2.43 MAX<br>2p (63.5) | CLP (6 1 .7)<br>**----- End of picture text -----**<br> *More configurations available. 6/11 Magnecraft Solution Guide 105A
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →