Image not available
Illustrative purposes only
18PLUS-AM02-00-PT01-01
Circuit Breaker Accessory, DIN Rail Mount, ETA ESS30-S003/ESX10-103 Electronic Circuit Breakers
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: ETA
- Product type: Circuit Breaker Accessories
- SVHC: No SVHC (17-Jan-2022)
- For Use With: ETA ESS30-S003/ESX10-103 Electronic Circuit Breakers
- Product Range: -
- Accessory Type: 18plus Connection Module
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 58.06 € |
| Current stock | 10+ |
| Lead time | 30 days |
**18plus module** ## **Description** Wiring of load and signal lines in a space-saving manner will become ever more important for designers of electrical plants and systems, because all control cabinets and control boxes will have to be more and more compact due to the growing decentralisation of the entire automation technology. A significant cost reduction for the complete power distribution including wiring in the control cabinet will also play an important role. The 18plus module holds a complete mounting and power distribution system for DIN rail mounting which has, together with the busbars, a fully-featured 80 A power distribution for the DC 24 and DC 48 voltage level without additionally required terminals and connection lines. It allows a cost-effective realisation of e.g. an 11-way protection system, because you only have to plug in the 11 required 2210-S, ESS30 or ESX10 circuit breakers or protectors into the ready slots of the connection modules. Each connection module can be operated with max. 20 A load current. The signalling circuits of the individual devices for the group signalling by means of an integral auxiliary make contact are already pre-wired in this system. Line entry of the DC 24 V / DC 48 V supply for LINE+, 0 Volt and functional earth FE is by means of plug-in type busbars. If no FE potential is supplied, all FE terminals may also be used as additional 0-Volt distribution. All electrical connections are made by means of push-in terminals with the following properties: - l All conductors can be plugged in easily and without tools - l Reliable contact making - l Firm connection of the conductors due to high pull-out forces - l Facilitated operation with any tool - l Contact reliability in the event of shock and vibration - l Gas-tight connection **==> picture [32 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> 18plus<br>**----- End of picture text -----**<br> is 20 A per slot. By mounting the individual 18plus-AM connection modules side-by-side, all internal wiring connections are established for the group signalling. The make contacts of the plugged in electro-mechanical or electronic circuit breakers are connected in series on this occasion. In addition, a 10 mA load is included in the 18plus-SM signalling module holding a green LED indication. This also enables the connection of PLC or ET200 inputs with a high internal resistance value. ## **18plus module fitted with 2210-S:** The integral auxiliary contact (make contact) of the thermal-magnetic 2210-S circuit breakers can be used for the group signalling. All required terminals (make contacts opening in the event of a failure) in the 18plus module are connected in series for this purpose. Group signalling is realised via terminal 13 integrated in the supply module, the signal output is located in the 18plus-SM signal module, terminal 14. An additional signal load of 10 mA can be realised via the 0 V terminal of the control at terminal 17. - l Maintenance-free ## **18plus module fitted with ESS30-S003:** All pushers were designed in four different colours (red, blue, orange, grey) so as to easily distinguish the different voltage potentials and functions of the device. Red = conductor: supply 24 V/48 V/LINE+ or protected load output/LOAD+ Blue = return conductor: supply 0 Volt or load/0 Volt Orange = functional earth supply FE or load/FE Grey = signalling circuits: supply 24V/terminal 13 or signal output terminal 14, LED load terminal 17 The 18plus module can be used in combination with the following plug-in type overcurrent protection devices: l **Thermal-magnetic circuit breaker 2210-S** l **Electronic circuit breakers ESS30-S003** l **Electronic circuit protectors ESX10-103, ESX10-S103** The 18plus module consists of three different basic modules: - **18plus-EM-... supply module** terminal 1 (LINE +), terminal 3 (0 V), terminal 4 (FE) terminal 13 (aux. contact input) The 0 V reference potential of the 18plus-AM connection module for the ESS30-S is already directly connected to the 0 V potential of the 18plus-EM supply terminal and is then looped through to the next AM element over the blade terminals on the side. This means: The side-by-side mounting (plug together) of the individual AM modules simultaneously establishes all internal wirings for the 0 V potential and for the group fault indication (series connection of make contacts). The ESS30-S003 has an integral auxiliary contact (change over contact). The SC-S0 contact is used for the group fault indication. For this purpose the contacts for this signalling are already connected in series in the 18plus modules. These are connected via two terminals – 13 (supply in 18plus-EM) and 14 (output in 18plus-SM). ## **18plus module fitted with ESX10-103/ESX10-S103:** The 0 V reference potential of the 18plus-AM connection module for the ESX10-103 or the ESX10-S103 is already directly connected to the 0 V potential of the 18plus-EM supply terminal and is then looped through to the next AM element over the blade terminals on the side. This means: The side-by-side mounting (plug together) of the individual AM modules simultaneously establishes all internal wirings for the 0 V potential and for the group fault indication (series connection of make contacts). - **18plus-AM-... connection module** terminal 2.1/2.2 (LINE +), terminal 3.1/3.2 (0 V), terminal 4.1/4.2 (FE) **- 18plus-SM-... signalling module** terminal 14 (aux. contact output) terminal 17 (GND for integral signal load 10mA with LED indication) The ESX10-103 or ESX10-S103 have an integral auxiliary contact (change over contact). The SC-S0 contact is used for the group fault indication. For this purpose the contacts for this signalling are already connected in series in the 18plus modules. These are connected via two terminals – 13 (supply in 18plus-EM) and 14 (output in 18plus-SM). The 18plus-AM connection module has been designed to accommodate single pole circuit breakers and other overcurrent protection devices. Those will be plugged into the 18plus-AM connection modules. The single-way AM modules can be mounted side by side, enabling bigger distribution systems with up to 30 slots. Each AM module is fitted with 4 mm² push-in terminals for double connection of DC 24 V / DC 48 V loads via L+, 0V and FE, the max. load current **www.e-t-a.de** 2227 1 **18plus module** ## **Technical Data** ## **Technical Data** |**Plug-in type**<br>2210-S; ESS30-S003;<br>**circuit breakers**<br>ESX10-103;ESX10-S103;<br>**Rated voltage**<br> AC 250 V; DC 24 V (optional to DC 80 V)<br>IEC 60947-7-1<br>300 V / 30 V(UL 1059)<br>**Rated voltage**<br>DC 24 V; 10 V...30 V<br>DC 48 V; 10 V...60 V<br>(without signal path max. DC 24 V)<br>Observe the voltage specifications of<br>theprotective device<br>**Rated**<br>AC 250 V<br>**insulation voltage**<br>**Main circuit, rated current IN**<br>supply module<br>80 A (IEC 60947-7-1)<br>65 A (UL1059)<br>connection module<br>20 A (IEC 60947-7-1)<br>16 A(UL1059)<br>**Signal circuits, rated current IN **<br>min. current<br>(terminals 13 – 14)<br>min. 10 mA at DC 10 V<br>max. current<br>max. 1 A at DC 24 V<br>integral current load<br>(terminals 13 – 17)<br>typically12 mA at DC 24 V<br>**Busbar for power distribution**<br>insulated busbar<br>Imax.80 A(65 A UL 1059)<br>**Ambient**<br>**temperature**<br>-30 °C ... +60 °C<br>**Installation**<br>**temperature**<br>+5 °C ... +60 °C<br>**Storage temperature**<br>-40 °C ... +70 °C<br>**Mounting position**<br>as desired<br>**Creepage resistance**<br>PTI 600<br>**Mounting**<br>symmetrical rail EN 50022-35x7.5<br>symmetrical rail EN 50022-35x15/1.5<br>**EM supply module**<br>push-in terminal PT 16<br>terminals (1; 3; 4)<br>0.5 – 16 mm2;<br>rigid (without) wire end ferrule*<br>20 – 6; AWG<br>0.5 – 16 mm2;<br>flexible (without) wire end ferrule*<br>20 – 6; AWG<br>0.5 – 16 mm2; flexible with<br>wire end ferrule* without plastic sleeve<br>0.5 – 16 mm2; flexible with<br>wire end ferrule* withplastic sleeve<br>terminals (13; 15; 16)<br>push-in terminal PT 4<br> 0.2 – 6 mm2; rigid (without) wire end ferrule*<br>24 – 12; AWG<br>0.2 – 4 mm2; flexible (without)<br>wire end ferrule*<br>24 – 12; AWG<br>0.25 – 4 mm2; flexible with<br>wire end ferrule* without plastic sleeve<br>0.25 – 4 mm2; flexible with<br>wire end ferrule* withplastic sleeve<br>**AM connection module**<br>push-in terminal PT 4<br>terminals<br>0.2 – 6 mm2.; rigid (without) wire end ferrule*<br>(2.1; 2.2; 3.1; 3.2; 4.1; 4.2)<br>24 – 12; AWG<br>0.2 – 4 mm2; flexible (without)<br>wire end ferrule*<br>24 – 12; AWG<br>0.25 – 4 mm2; flexible with<br>wire end ferrule* without plastic sleeve<br>0.25 – 4 mm2; flexible with<br>wire end ferrule* withplastic sleeve|**SM signalling module**<br>push-in terminal PT 4<br>terminals (14; 15; 16)<br> 0.2 – 6 mm2; rigid (without) wire end ferrule*<br>24 – 12; AWG<br>0.2 – 4 mm2; flexible (without)<br>wire end ferrule*<br>24 – 12; AWG<br>0.25 – 4 mm2; flexible with<br>wire end ferrule* without plastic sleeve<br>0.25 – 4 mm2; flexible with<br>wire end ferrule* withplastic sleeve| |---|---| ||**Wire stripping length**| ||Push-in terminal PT 16<br>18 mm<br>Push-in terminal PT 4<br>11 mm| ||**Insulation co-ordination (IEC 60664-1)**<br>Main circuit<br>rated impulse voltage<br>4kV<br>pollution degree<br>3<br>Overvoltage category III<br>Auxiliary circuit<br>rated impulse voltage<br>0,8 kV<br>pollution degree<br>3<br>Overvoltage categoryIII| ||**Dielectric strength**<br>Main circuit to main circuit<br>1500 V<br>Main circuit to auxiliary circuit<br>1500 V<br>Auxiliarycircuit to auxiliarycircuit<br>1500 V| ||**Insulation resistance**<br>> 100 MΩ(DC 500 V)| ||**Typical internal resistance values**| ||Main circuit<br>(EM1 – AM2.1/2.2);<br>without device<br>5 mΩ| ||Auxiliary circuit<br>(1 x EM, 4 x AM, 1 x SM);<br>without device<br>60 mΩ;<br>(13 – 14 / make contact)<br>(+5 mΩ for each added AM)| ||**Typical mounting values (circuit breaker)**<br>Typical push-in force<br>approx. 130 N<br>Typicalpull-out force<br>approx. 150 N| ||**Number of push-on operations**<br>devices<br>50<br>busbar<br>20| ||**Mass**<br>18plus EM<br>approx. 70 g<br>18plus AM<br>approx. 60 g<br>18plus SM<br>approx. 45g| ||**Vibration (sinusoidal)**<br>test to IEC 60068-2-6,<br>test Fc<br>5g (57-500Hz),± 0,38 mm(10-57 Hz)| ||**Shock**| ||test to IEC 60068-2-27,<br>test Ea<br>25g (11 ms)| ||**Humidity**| ||test to IEC 60068-2-78,<br>test Cab<br>240 hrs. in 95 % RH| ||**Corrosion**| ||Test to DIN IEC 60068-2-11,<br>test Ka<br>96 hours in 5 % salt mist| ||*) Application note: We recommend a square crimp shape when using wire<br>end ferrules.| **www.e-t-a.de** 2 2227 **18plus module** ## **Approvals** |**Approval**<br>**authority**|**Standard**|**File-Certificate Nr.**|**Rated voltage**|**Rated voltage**| |---|---|---|---|---| |UL|UL1059, CSA C22.2, No. 158|E335289 V1 S3|300 V / 30 V (signal)|65 A / 16 A / 1 A (signal)| ## **CE logo** ## **Available versions** CE logo according to EN 60947-7-1 ## **Features and Benefits** - l Complete mounting and power distribution system for rail mounting - l Together with the busbars it holds a fully-fledged 80 A potential distribution of the DC 24 V / DC 48 V control voltage without - additionally required connection terminals or connecting cables - l All electrical connections are implemented via screwless push-in terminals. All pushers were designed in four different colours (red, blue, orange, grey) so as to easily distinguish the different voltage potentials and functions of the device. 18plus-EM02-0018plus supply module, compact version PT01-01 with group signalling make contact 18plus connection module for 2210-S, 18plus-AM02-00ESS30-S003, ESX10-103/ESX10-S103 PT01-01 circuit breakers, compact version with group signalling make contact 18plus signalling module for compact 18plus-SM02-01PT01-01 version with group signalling make contact, with integral 10 mA signal load 18plus-SM00 18plus spacer / empty housings Supply terminals PLUS connecting terminals PLUS signalling terminals PLUS integral wiring harness PLUS flexible circuit breaker population ... ... mutually complete their effects - l Modular compact power distribution system for rail mounting as a complete package - l Load wiring with integral terminals without additional potential distribution - l Plug-in type overcurrent protection for all requirements in the DC 24 V / DC 48 V area - l Integral power distribution up to 80 A - l Integral group signal wiring, make contacts - l Future bus connection for _**ControlPlex[®]**_ applications - l Push-in terminals for reliable wiring, even with shock and vibration ## **User benefits** - l Saves component costs for wiring and for additional parts because the cable harness and the potential distribution are already included - l Reduces costs through facilitated electrical planning, easy mounting in system and plant service and easy procurement etc. - l Perfectly matches centralised and decentralised power distribution concepts - l Saves expenses in logistics through use of only few, standardised components - l High application flexibility through population with different circuit breaker models **www.e-t-a.de** 2227 3 **18plus module** ## **Mounting** **==> picture [249 x 692] intentionally omitted <==** **----- Start of picture text -----**<br> Mounting the modules:<br>1.<br>2.<br>1. Snap module onto rail<br>2. Push modules on the rail<br> until they catch on audibly<br>Mounting the busbars:<br>3.<br>3. When all modules are<br> positioned correctly, insert<br> busbars in correct position<br> until stop<br>**----- End of picture text -----**<br> ## **Disassembly** **==> picture [249 x 489] intentionally omitted <==** **----- Start of picture text -----**<br> Removing the busbars:<br>1.<br>2.<br>1. Push away signalling module to<br> remove busbar<br>2. Pull busbar out of the groove<br>Removing the modules:<br>1.<br>2.<br>1. Push modules apart<br>2. Remove module from rail:<br> put screwdriver with a 4 mm<br> blade to foot<br>**----- End of picture text -----**<br> **www.e-t-a.de** 4 2227 **18plus module** ## **Dimensions of socket system** **==> picture [249 x 195] intentionally omitted <==** **----- Start of picture text -----**<br> Symmetrical rail Label optional<br>EN 50022-35x7.5<br>13.5 n x 13.1 58.3<br>13.1 13.1 42.5<br>7.5<br>Knock-out Label<br>protection against optional<br>brush contact<br>66.3<br>130±0.8<br>**----- End of picture text -----**<br> ## **Dimensions AM** ## **Dimensions EM** **==> picture [249 x 196] intentionally omitted <==** **----- Start of picture text -----**<br> 13.5 42.5<br>7.5<br>130±0.8<br>**----- End of picture text -----**<br> ## **Dimensions SM** **==> picture [511 x 464] intentionally omitted <==** **----- Start of picture text -----**<br> 58.3<br>42.5<br>13.1<br>13.1 34.7<br>7.5<br>7.5<br>42.5<br>Wiring diagram, without circuit breakers<br>PE N L<br>AC<br>DC24V<br>- - + +<br>X1 X1 X1<br>1<br>X3 X3 X3<br>e.g. ST 16-PE 3b 3a 3b 3a 3b 3a 3b<br>X13 X13 X13<br>13b13a 14b 13a 14a 13a 14b 14a<br>13<br>X14 X14 X14<br>X2.1 X2.1 X2.1 X2.1 X2.1 X2.1<br>2.1 2.2 2.1 2.2 2.1 2.2<br>LED<br>3<br>3.1 3.2 3.1 3.2 3.1 3.2 17<br>4 4.1 4.2 4.1 4.2 4.1 4.2 14<br>Mass for current load<br>SIFA on I/O module<br>66.3<br>130±0.8<br>130±0.8<br>18plus-EM02-00-PT01-01 18plus-AM02-00-PT01-01 18plus-SM02-00-PT01-01<br>**----- End of picture text -----**<br> **www.e-t-a.de** 2227 5 ## **2210-S - 18plus module** ## **Dimensions, with 2210-S** **==> picture [249 x 157] intentionally omitted <==** **----- Start of picture text -----**<br> 113 (max. 115 mm)<br>13.1<br>7.5<br>130±0.8<br>**----- End of picture text -----**<br> ## **Pin assignment, with 2210-S** **==> picture [249 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> 2210-S.. 18plus module<br>compact<br>1 1<br>11 (n.a.) 3<br>23 13<br>24 14<br>12 (n.a.)<br>2 2.1, 2.2<br>**----- End of picture text -----**<br> ## **Schematic diagram, with 2210-S** **==> picture [249 x 261] intentionally omitted <==** **----- Start of picture text -----**<br> EM AM... ...AM SM<br>1<br>13<br>|> |><br>2.1 2.2 2210 2.1 2.2 2210 LED<br>3<br>3.1 3,2 3.1 3.2 17<br>4 4.1 4.2 4,1 4.2 14<br>EM SM<br>1 line 14 signalling<br>3 0 Volt 17 load 24 V / 10 mA<br>4 FE<br>13 signalling<br>AM<br>2.1, 2.2 load<br>3.1, 3.2 0 Volt<br>4.1, 4.2 FE<br>**----- End of picture text -----**<br> **www.e-t-a.de** 6 2227 **ESS30-S.../ESX10-... - 18plus module** ## **Dimensions, with ESS30-S003** **==> picture [249 x 174] intentionally omitted <==** **----- Start of picture text -----**<br> With optional retaining clip:<br>107 (OFF 113)<br>13.1<br>7.5<br>130±0.8<br>**----- End of picture text -----**<br> ## **Schematic diagram, with ESS30-003** **==> picture [249 x 275] intentionally omitted <==** **----- Start of picture text -----**<br> EM AM... ...AM SM<br>1<br>13<br>2.1 2.2 ESS30-S003 2.1 2.2 ESS30-S003 LED<br>3<br>3.1 3.2 3.1 3.2 17<br>4 4.1 4.2 4.1 4.2 14<br>EM SM<br>1 line 14 signalling<br>3 0 Volt 17 load 24 V / 10 mA<br>4 FE<br>13 signalling<br>AM<br>2.1, 2.2 load<br>3.1, 3.2 0 Volt<br>4.1, 4.2 FE<br>**----- End of picture text -----**<br> ## **Pin assignment, with ESS30-S003** **==> picture [249 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> ESS30-S003 18plus module<br>compact<br>LINE (+) 1<br>GND 3<br>SC 13<br>SO 14<br>SI (n.a.)<br>LOAD (+) 2.1, 2.2<br>**----- End of picture text -----**<br> ## **Dimensions, with ESX10-103 / ESX10-S103** **==> picture [249 x 173] intentionally omitted <==** **----- Start of picture text -----**<br> 106<br>13.1<br>7.5<br>130±0.8<br>**----- End of picture text -----**<br> ## **Schematic diagram, with ESX10-103 / ESX10-S103** **==> picture [249 x 275] intentionally omitted <==** **----- Start of picture text -----**<br> EM AM... ...AM SM<br>1<br>13<br>2.1 2.2 ESX-103 2.1 2.2 ESX-103 LED<br>3 ...-S103 ...-S103<br>3.1 3.2 3.1 3.2 17<br>4 4.1 4.2 4.1 4.2 14<br>EM SM<br>1 line 14 signalling<br>3 0 Volt 17 load 24 V / 10 mA<br>4 FE<br>13 signalling<br>AM<br>2.1, 2.2 load<br>3.1, 3.2 0 Volt<br>4.1, 4.2 FE<br>**----- End of picture text -----**<br> ## **Pin assignment, with ESX10-103 / ESX10-S103** **==> picture [249 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> ESX10-103 18plus module<br>ESX10-S103 compact<br>LINE (+) 1<br>GND 3<br>SC 13<br>SO 14<br>SI (n.a.)<br>LOAD (+) 2.1, 2.2<br>**----- End of picture text -----**<br> **www.e-t-a.de** 2227 7 **18plus module** ## **Accessories** **==> picture [512 x 526] intentionally omitted <==** **----- Start of picture text -----**<br> Retaining clip Y 311 978 01<br>Busbar<br>X 222 611 02 busbar for LINE, 0 V, FE,<br>grey insulation, 500 mm<br>FTG-Busbar<br>X 223 571 01 busbar for LINE, 0 V, FE,<br>grey insulation, 500 mm<br>500<br>Installation example with ESS30-S<br>with optional retaining clip<br>X 222 977 50<br>white marking label, unmarked, packaging unit = 50 pcs,<br>(10 strips, 1 strip consists of 5 labels)<br>12<br>Jumper<br>SB-S11-P1-01-1-1A<br>top view<br>Germany<br>Signalbrücke<br>Signal loop<br>SB-S11-P1-01-1-1A<br>www.e-t-a.com<br>xxxx<br>Retaining clip Y 307 754 01<br>Retaining clip for ESS20 / ESX10 /<br>SB-S11-P1-01-1-1A<br>18.5<br>AC 240 V / DC 65 V, 1 A<br>12.3<br>1.3 2<br>contakt 13+14 blade terminal<br>bridged DIN 46244-A 6.3-0.8<br>3<br>60<br>70<br>Signalbrücke Signal loop<br>1.7<br>1 13 14 2<br>10.3<br>4.8 8<br>**----- End of picture text -----**<br> All dimensions without tolerances are for reference only. E-T-A reserves the right to change specifications at any time in the interest of improved design, performance and cost-effectiveness without notice. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. **www.e-t-a.de** 8 2227
Updated at April 26, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →