Power Line Filter, General Purpose, 480 VAC, 7 A, Three Phase, 2 Stage, Chassis Mount
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TE CONNECTIVITY - CORCOM
- Product type:
- SVHC: To Be Advised
- No. of Phases: Three Phase
- No. of Stages: 2 Stage
- Product Range: BCF Series
- Current Rating: 7A
- Voltage Rating: 480VAC
- Filter Mounting: Chassis Mount
- Filter Applications: General Purpose
- Filter Input Terminals: Terminal Block
- Filter Output Terminals: Terminal Block
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 92.06 € |
| Current stock | 10+ |
| Lead time | 30 days |
# **Corcom Product Guide**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## RFI Power Line Filters
TE Connectivity (TE) offers over 300 solutions for RFI problems associated with susceptibility, as well as compliance with international emissions standards.
## IEC Inlet Filters and Power Entry Modules
A complete line of power entry modules solves a variety of power entry needs by combining functions to reduce cost, space and labor.
## TE Connectivity Corcom Products Engineering Offices
## USA
620 S. Butterfield Road Mundelein, IL 60060 Phone: 847-680-7400 Fax: 847-680-8169
6700 Fallbrook Ave. Suite 287 West Hills, CA 91307 Phone: 818-226-4306 Fax: 818-704-1757
## Germany
Finsinger Feld 1 D-85521 Ottobrunn, Phone: 49-89-6089-0 Fax: 49-89-6089-767
## People’s Republic of China
## DC Filters
TE has developed a wide range of power line filters and power entry modules that combine several power management functions specifically designed for DC applications.
## Feedthrough Filters and Capacitors
668 Guiping Road Shanghai, 200233 Phone: 86-21-2407-1588 Fax: 86-21-2407-1599
For Sales assistance in the USA please refer to page 286 to find a Corcom product sales representative in your area. For Sales assistance in all other regions, please refer to page 289 to find the Product Information Center in your area.
Designed to offer reliability and performance in high frequency applications and meet EN132200 and 132400 safety requirements. Available for AC or DC applications.
## Signal Line Products
The SignalSentry filtered modular jack connector series combines different levels of filtering with RJ45 and RJ11 modular jacks to address signal line noise problems and crosstalk.
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Main Table of Contents**
||Navigating the Catalog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3|
|---|---|
|1<br>.<br>R<br>1.|R<br>F<br>I<br>P<br>o<br>w<br>e<br>r<br>L<br>i<br>n<br>e<br>F<br>i<br>l<br>t<br>e<br>r<br>s<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>9<br>RFI Power Line Filters ........0ccceccccssscsvvvcvcsescessvveveeess9|
||RFI Power Line Filter Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11|
||AQ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12|
||B Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15|
||DK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18|
||EBP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21|
||EDP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21|
||EOP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21|
||EMC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24|
||EP & VP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27|
||FC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30|
||FL Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33|
||G Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35|
||HQ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37|
||HT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40|
||HZ Series NEW 4, 6, 10 and 20A versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43<br>ee|
||IK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46|
||K Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49|
||MV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54|
||N Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56|
||Q Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58|
||R Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61|
||RK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65|
||S Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68|
||SB Series NEW High Performance B Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71<br>~~a~~|
||SK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75|
||T Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80|
||U Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84|
||V Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86|
||W Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86|
||WG Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89|
||X Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92|
||Y Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92|
||Z Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92|
|2<br>.<br>T<br>2.|T<br>h<br>r<br>e<br>e<br>P<br>h<br>a<br>s<br>e<br>F<br>i<br>l<br>t<br>e<br>r<br>s<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>9<br>7<br>Three Phase Filters .......ccc cece cv vveevcesssssvvvvcesessesvvve<br>0D|
||Three Phase Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97|
||A Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98|
||ADT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101|
||AYA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104|
||AYC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108|
||AYO Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111|
||BCF Series NEW Compact Three Phase Filters . . . . . . . . . . . . . . . . . . . . . . . . . .113<br>eel|
||CFN Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116|
||FCD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118|
|3<br>.<br>P<br>3.|P<br>o<br>w<br>e<br>r<br>I<br>n<br>l<br>e<br>t<br>F<br>i<br>l<br>t<br>e<br>r<br>s<br>&<br>P<br>o<br>w<br>e<br>r<br>E<br>n<br>t<br>r<br>y<br>M<br>o<br>d<br>u<br>l<br>e<br>s<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>1<br>2<br>5<br> Power Inlet Filters<br>& Power Entry Modules ........0ec0ceeeceeee0<br>0125|
||Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126|
||Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128|
||Power Entry Module Selector Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129|
||C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130|
||CU Series NEW Compact 1U Height Power Entry Module . . . . . . . . . . . . . . . .134<br>~~|~~|
||EBF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138|
||EC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141|
||ED Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144|
||EEA & EEB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|
||EAS & EBS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|
||EAH & EBH Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|
||EEJ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153|
1
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help**
**corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Table of Contents** _(continued)_
|EJH & EJHS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153|
|---|
|EJM & EJMS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153|
|EJS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153|
|EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160|
|EJT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163|
|GG & HG Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166|
|H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169|
|J Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172|
|L Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175|
|LA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180|
|M Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183|
|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192|
|SR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201|
|SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203|
|4<br>.<br>D<br>C<br>F<br>i<br>l<br>t<br>e<br>r<br>s<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>0<br>9<br>4, DC Filters ..... ccc ccc cece caccccevvvvcsscasvevvvvsssssssssseeee<br>2LO9|
|Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .210|
|Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .211|
|DA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212|
|DB Series NEW - Compact RFI High Current DC Inlet . . . . . . . . . . . . . . . . . . . .214|
|DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217|
|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|
|5<br>.<br>F<br>e<br>e<br>d<br>t<br>h<br>r<br>o<br>u<br>g<br>h<br>F<br>i<br>l<br>t<br>e<br>r<br>s<br>a<br>n<br>d<br>C<br>a<br>p<br>a<br>c<br>i<br>t<br>o<br>r<br>s<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>2<br>5<br>5.Feedthrough<br>Filters and Capacitors ........cccccccccccccevvecee<br>225|
|Feedthrough Application Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225|
|Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226|
|FFA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228|
|FFD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231|
|AFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234|
|DFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .237|
|6<br>.<br>S<br>i<br>g<br>n<br>a<br>l<br>L<br>i<br>n<br>e<br>P<br>r<br>o<br>d<br>u<br>c<br>t<br>s<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>4<br>1<br>6. Signal Line Products .......ccccccecceccccccscscnceccsscssccsces<br>dl|
|Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242|
|SignalSentry Filtered Modular Jacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .243|
|SignalSentry Part Number Matrix / Ordering Information . . . . . . . . . . . . . . . . .244|
|SignalSentry Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245|
|L Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .247|
|L – Ganged Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248|
|LC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .249|
|LCT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250|
|N Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .251|
|X Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .252|
|Z Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253|
|Model Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255|
|L, LC, LCT and X Series RJ Jack Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .255|
|N and Z Series RJ Jack Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .257|
|7<br>.<br>T<br>e<br>c<br>h<br>n<br>i<br>c<br>a<br>l<br>N<br>o<br>t<br>e<br>s<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>6<br>1<br>7. Technical NOTES ...... ccc cece vv eve ccccsssssvvvvvsscscessssseees<br>LOl|
|Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .262|
|Understanding RFI Power Line Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .263|
|Understanding Hipot Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .266|
|Understanding Leakage Current (Touch Current) . . . . . . . . . . . . . . . . . . . . . . . . .267|
|Understanding Insertion Loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .268|
|Appendix A - Conducted RFI Emissions Testing . . . . . . . . . . . . . . . . . . . . . . . . . .269|
|Appendix B - Conducted RFI Susceptibility Testing . . . . . . . . . . . . . . . . . . . . . . .270|
|Appendix C - Health Care Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270|
|Appendix D - Safety Agency File Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271|
|Part Number Index and Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273|
|North American Sales Representatives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286|
|Authorized Corcom Product Distributors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .288|
|W<br>o<br>r<br>l<br>d<br>w<br>i<br>d<br>e<br>C<br>o<br>n<br>t<br>a<br>c<br>t<br>s<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>I<br>n<br>s<br>i<br>d<br>e<br>B<br>a<br>c<br>k<br>C<br>o<br>v<br>e<br>r<br>Worldwide ContactS ........2cecccceeeeesssseeeee+-<br>0nsideBackCover|
2
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1 2**
**3**
**4**
**7**
## **Navigating the Catalog**
## Step 1: Determine the product family.
The Corcom product guide contains seven sections with six distinct product families. Use the index numbers along the side of the catalog to quickly jump to that section.
## RFI Power Line Filters
Solutions associated with EMI/RFI susceptibility as well as compliance to international emissions standards for single phase power applications. Includes chassis and board mountable designs as well as single and two-stage filters.
## Three Phase Filters
Solutions associated with EMI/RFI susceptibility as well as compliance to international emissions standards for three phase and high current applications.
**==> picture [11 x 179] intentionally omitted <==**
**----- Start of picture text -----**<br>
Corcom Product Families<br>**----- End of picture text -----**<br>
## IEC Inlet and Power Entry Modules
- IEC inlet power filters and modular products that address a variety of power entry needs by combining several functions such as on/off switching, voltage selection switching, fuseholder, filtering in combination with the IEC inlet connector.
## DC Power Line Filters
- EMI/RFI solutions for emissions and susceptibility specifically related to DC systems often found in central office and telecommunication applications.
## Feedthrough Filters and Capacitors
~~**1**~~ Products designed for through-bulkhead mounting for high frequency filtering. ! 1' Designed to meet EN133200 and EN132400 safety requirements. Available in a **5** 1 ' variety of standard as well as custom configurations. 1 ' **1** ~~' 1 ' 1 '~~ ~~**1**~~ Signal Line Products ~~! 1~~ ' Products that combine different levels of filtering with various sized RJ modular 1 '1 jacks. Signal line products are used to protect data transmissions as they pass **6** ' **1** through the RJ jacks or as they are transmitted on the PCB.
## Technical Notes
The appendices in the back of the catalog offer information such as safety agency classifications, general information regarding RFI, and testing procedures.
_(continued on next page )_
Looking for Corcom EMI Facility Products? Power, data and signal line filters for shielded installations Available in Catalog 1654986 - see page 8 for more information
3
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Navigating the Catalog** _(continued)_
## Step 2: Use selector charts
Selector charts at the beginning of each section help you to narrow the selection.
Follow the chart to locate one or several product series that could fit your specific application and requirements.
Optimal filter selection requires testing in your specific system, as all systems have unique characteristics.
Selector charts generally show filters in order of performance from good (at the top) to best performance (at the bottom).
**==> picture [221 x 209] intentionally omitted <==**
**----- Start of picture text -----**<br>
For<br>ConductedAttenuateRFI / EMI of EquipmentComing Out ApplicationsEquipmentHardened Yes<br>Try The<br>No AQ<br>Coming Into Series<br>Equipment For 3-6A<br>Switch Page 12<br>Mode Power<br>No Supply Yes<br>For<br>Noise Industrial ApplicationFor High EN550xxx(CISPR) Class A<br>Yes No Try The<br>Class B X, Y or ZSeries<br>1- 6A<br>Page 92<br>RK<br>Series<br>3-20A<br>Try The Try The Page 65<br>B EBP, EDP,EOP SK<br>Series Series Series<br>1-30A 1-10A 3-40A<br>Page 15 Page 21 Page 75<br>SB B EMC<br>Series Series Series<br>NEW<br>W<br>**----- End of picture text -----**<br>
## Step 3: Open to the page referenced by the selector chart
Each product series contains three technical sections. The majority of questions relating to product applications can be answered directly from these sections.
Technical Characteristics: This first section contains pictures, appropriate safety agency classifications, a description of the series’ capabilities, applications, electrical specifications, schematics, ordering information and available part numbers.
Drawings: The second section contains drawings and dimensions of the parts as well as the recommended cutouts. Dimensions are shown in inches with metric equivalents.
Performance Data: The third section contains performance data in the form of typical insertion loss graphs and minimum insertion loss tables.
If you already know the catalog number or series, the table of contents lists each series in the catalog within each section. The back of the catalog also has an index in alphanumeric order. The index will reference the technical section for that catalog number or series. The index also provides the unique TE ordering number for each part.
## Step 4: Contact your local Corcom product sales representative
Corcom product sales representatives for North America as well as distributors and global contacts are listed in the back of the catalog. Contact the sales representative or office closest to you for technical assistance, stock and pricing.
4
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Corcom EMI/RFI Filters and Energy Efficiency**
**==> picture [80 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cool<br>liable Effici<br>e e<br>R n<br>t<br>**----- End of picture text -----**<br>
The efficiency of an electrical device is the ratio of the power it delivers to the power that it consumes. The difference is wasted as heat, and to prevent overheating of a device and the system in which it resides, this heat must be transferred out of the system and dissipated. The efficiency of every component, including the power entry module and selected filter, factors into the system’s overall efficiency. When the amount of heat is too great to dissipate through the system’s enclosure, forced air cooling becomes necessary. This is often accomplished with a fan, and the power used by that fan, (including its own thermal losses) further decreases the system efficiency by another 2% to 5%. Providing room for the fan and air passageways in the equipment increases its size and cost. Careful attention to the efficiency of every component in the system results in a simpler, smaller, lighter, cooler, more competitive product.
Corcom EMI filters can help meet energy efficiency goals, including Energy Star rating and the new 80 Plus certification, which now recognizes systems that exceed 90% efficiency. By using the most energy efficient design and materials, Corcom filters can be the beginning of an energy efficient system strategy.
Energy efficient power components don’t just lower energy bills and demand for power from the grid, they also increase product reliability. Small efficiency increases can decrease component temperatures throughout the system, and semiconductor life doubles for every 10°C decrease in temperature. Corcom filters are more efficient and run cooler, and this can help reduce system warranty costs, service calls and total support costs.
## Corcom filters
- Have heat dissipation ratings as little as one third that of comparable filters.
- Create less heat and run cooler
- Improve system reliability
- Are more efficient than PC board equivalents
- Can help meet system power efficiency standards
- Enable systems to be smaller and lighter
- Save customers money by reducing energy costs
**==> picture [369 x 184] intentionally omitted <==**
**----- Start of picture text -----**<br>
500<br>450<br>400<br>350<br>300<br>250<br>200<br>150<br>100<br>50 Other Power Entry Modules<br>0<br>Corcom CU Series<br>1A<br>3A<br>Heat Dissipation in mW/A<br>**----- End of picture text -----**<br>
5
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Corcom Products Engineering Services and Custom Solutions**
## Corcom Products Engineering Services and Custom Solutions
TE Connectivity Corcom products were established as the world leader in EMI/RFI filtering technology with the introduction of the first line of catalog filter products over 50 years ago.
Today, TE continues to pursue the latest in EMI/RFI filter design by testing and evaluating application specific solutions for a wide range of industries.
In addition to our complete catalog of standard EMI/RFI filtering solutions, TE offers a full range of engineering services and custom products designed for unique applications.
Corcom custom EMI/RFI product solutions can:
- Optimize both cost and performance to target a unique application
- Fit unique mechanical size, installation and/or connection requirements
- Ensure conformance with EMI/RFI requirements of an entire system
- Apply EMI/RFI filtering in a specific frequency or range
## Corcom Custom Filters Key Features:
- Custom filter options
- Custom wire harness design
- Fully customizeable options including packaging
- Agency approvals available as needed by customer
- Time and cost savings to customer
- Simplify installation
## Termination and Wiring Customization Options:
- Wire length
- Wire gauge
- Wire color
- Molded connectors
With design and testing facilities worldwide, TE is well suited to design an EMI/RFI solution that meets a wide range of unique application needs.
- Ring terminals
- Custom terminations
To discuss application specific filtering, contact the TE Corcom product sales representative or office closest to you. A complete list of sales representative and worldwide contacts is listed in the back of this catalog.
6
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Corcom Engineering Services and Custom Solutions**
## EMI/RFI Testing Services
Corcom Products Test Lab Key Features:
- We can test product to the FCC / EN / EFT specifications
- Let us know your testing needs and time frame to ensure flexibility of testing and timely results
Available Testing Standards:
- Conducted EMI in accordance with FCC part 15 and 18
- EN55011, EN55022 and EN55014
- EFT (Electrically Fast Transient) in accordance with EN61000-4-4
- Tests conducted up to 30A with insertion loss measured up to 10GHz
- MIL-STD-461 CE101 & CE102
An increase in electronic content and stringent regulatory compliance requirements have increased the need for time spent in qualifying test houses. At these “test labs,” products undergo a number of qualifying tests which include conducted emissions, EFT, and harmonic content. Failure to comply with associated standards can lead to delayed time-to-market and product redesign resulting in lost revenue and market share and an increase in time spent at the test lab.
TE Connectivity can help by heading off some of the potential pitfalls during testing and qualifying phases of new products. We offer complimentary testing to existing regulatory standards. We aim for a high standard of accuracy, and can help identify potential problems.
- We are not a certifying body and our test lab is not a qualified test lab; however, we test to the same standards and take product through the same rigor as any certifying lab. In addition, our engineers will recommend a solution and help with a design
- should a product fail to comply with conducted emissions, EFT and/or harmonic content standards.
The advantage is clear: TE will provide you with
- a high degree of confidence that a product which passed our
- in-house testing will pass agency testing at a certifying test house in reduced time and with reduced cost.
TE has three Corcom filter testing facilities:
- Mundelein, IL, USA (main office and design center)
- West Hills, CA, USA (regional office)
- Ottobrunn, Germany (regional office and design center)
7
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Corcom EMI / RFI Product Solutions for Facility and Heavy Power**
## Corcom EMI Facility Products
## Power, data and signal line filters for shielded installations
TE Connectivity has dedicated more than 50 years to developing RFI filter technology for electronic devices. We're proud that our focus on the design and production of the highest quality products has made TE a world leader in RFI technology.
Our leadership in the filter and power entry module markets was enhanced in 1988 with the aquisition of the Heavy Power Line Division of Cornell Dubilier. The high quality designs and manufacturing of these heavy power line filter products is maintained and enhanced by TE.
We have continued that dedication to excellence begun by Cornell Dubilier and inherent to TE’s way of doing business. Only the highest quality designs, capacitors, inductors, and workmanship are used to produce these filters. We recognize the need for great care demanded by hi-rel military filters and automatically apply like quality to the heavy power line products. We treat all product as if it is high-reliability.
The Mundelein, IL office provides application engineering service for these heavy power line and military products. Our engineers can help to design a special filter in the rare case a standard product from this catalog cannot adequately solve the problem. Additional product performance data and test results are available from the engineers at this facility.
TE’s worldwide sales offices can help you locate information on these products or any of the hundreds of high quality power line filters, power entry modules and SignalSentry products made by TE.
For more information on the complete line of EMI Facility products, request catalog number 1654986 or visit www.corcom.com
8
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **1. RFI Power Line Filters — Table of Contents**
> R RFI FI P Power ower L Line ine F Filter ilter S Selector elector C Chart hart . .......0cccccccvvcccccsssscevecveall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 AQ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 B Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 DK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 EBP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 EDP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 EOP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 EMC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 EP & VP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 FC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 FL Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 G Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 HQ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 HT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 HZ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 IK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 K Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 MV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 N Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 Q Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58 R Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 RK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 S Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68 SB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71 SK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75 T Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80 U Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84 V Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86 W Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86 WG Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89 X Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 Y Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 Z Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
9
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Engineering Notes**
10
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **RFI Power Line Filter Selector Chart**
**==> picture [542 x 601] intentionally omitted <==**
**----- Start of picture text -----**<br>
For<br>Medical No<br>Application<br>For<br>Attenuate Hardened<br>->- Conducted Coming Out Equipment Yes<br>Yes RFI / EMI of Equipment Applications<br>1<br>Try The<br>No<br>AQ<br>Coming Into Series<br>Try The Equipment For 3-6A<br>Switch Page 12<br>MV Mode Power<br>Series No Supply Yes<br>3-20A<br>Page 54<br>HZ For<br>Series For High EN550xxx Class A<br>3A Noise Industrial (CISPR)<br>Page 43 Application<br>HT Yes No Try The<br>Series6-15A Class B X, Y or Z<br>Series<br>Page 40 1- 6A<br>HQ Page 92<br>Series RK<br>3-6A<br>Series<br>Page 37 3-20A<br>I~ *<br>Try The Try The Page 65<br>B EBP, EDP,EOP SK<br>Series Series Series<br>1-30A 1-10A 3-40A<br>Page 15 Page 21 Page 75<br>SB B EMC<br>Series Series Series<br>6- 30A 1- 30A 3-30A<br>All Series Try The Page 71 Page 15 Try The Page 24<br>Are Listed in<br>PerformanceAscending EMC K SB Z S<br>Series Series Series Series Series<br>from 3-30A 1-60A 6- 30A 1-3A 3-60A<br>Page 24 Page 49 Page 71 Page 92 Page 68<br>Good FC DK K U V / W<br>Series Series Series Series Series<br>6-50A 1-20A 1-60A 6A 3-20A<br>to<br>Page 30 Page 18 Page 49 Page 84 Page 86<br>S WG DK N EP / VP<br>Series Series Series Series Series<br>3-60A 16A 1-20A 6-10A 3-20A<br>Better Page 68 Page 89 Page 18 Page 56 Page 27<br>to V / W EDP - EOP R Q G<br>Series Series Series Series Series<br>3-20A 1-10A 1-20A 3-20A 6-10A<br>Page 86 Page 21 Page 61 Page 58 Page 35<br>Best T R EMC FC T<br>Series Series Series Series Series<br>3-20A 1-20A 3-30A 6-50A 3-20A<br>Page 80 Page 61 Page 24 Page 30 Page 80<br>RFI Power Line Filters<br>NEW<br>NEW<br>NEW<br>New 60A<br>New 60A New Terminations<br>**----- End of picture text -----**<br>
11
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **High Frequency Power Line Filter or Power Entry Module**
## AQ Series
## UL Recognized CSA Certified
**==> picture [125 x 56] intentionally omitted <==**
**----- Start of picture text -----**<br>
3VAQ8F<br>6VAQ8F<br>**----- End of picture text -----**<br>
## A A@ Q S S Series eriesriesiesess
## A A@ Q S S Series eriesriesiesess
- Low cost solution to power line noise at high frequencies
- High common and differential mode performance from 10kHz to 1GHz
- Available with an IEC inlet, fuseholder and switch
- Suitable for applications where computers are used to process secret or confidential information
## O Ordering rdering I Information nformation
**==> picture [216 x 59] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 V AQ 8 FS<br>L Suffix Suffix<br>F – Fuseholder<br>FS – Fuseholder & Switch<br>**----- End of picture text -----**<br>
_(F & FS on VAQ8 only)_ Omit if none
I Input nput / Output / Output S Style tyle 3 – Wire leads 8 – IEC inlet* _(line side)_ Wire leads _(load side)_
> A AQ Q S Series eries
## S Specifications pecificationsecificationscificationsificationsficationscationsationstionsionsonsnss
## S Specifications pecificationsecificationscificationsificationsficationscationsationstionsionsonsnss
|S<br>pecificationsecificationscificationsificationsficationscationsationstionsionsonsnss<br>ecificationscificationsificationsficationscationsationstionsionsonsnss<br>cificationsificationsficationscationsationstionsionsonsnss<br>ificationsficationscationsationstionsionsonsnss<br>ficationscationsationstionsionsonsnss<br>cationsationstionsionsonsnss<br>ationstionsionsonsnss<br>tionsionsonsnss<br>ionsonsnss<br>onsnss<br>nss<br>s<br>Specifications|||
|---|---|---|
|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:||
||3A Models|6A Models|
|@ 120 VAC 60 Hz:<br>@250 VAC 50 Hz:|1.2 mA<br>2.3 mA|.7 mA<br>1.2 mA|
|Hipot rating (one minute):<br>Line to Ground:||2250 VDC|
|Line to Line:||1450 VDC|
|Rated Voltage (max):||250 VAC|
|Operating Frequency:||50/60 Hz|
|Rated Current:||3 or 6A|
|Operating Ambient Temperature Range<br>(at rated current Ir):<br>-10°C to +40°C<br>In an ambient temperature (Ta) higher than +40°C<br>the maximum operating current (Io) is calculated as<br>follows: Io = Ir ~~~~(85-Ta)/45|||
## E Electrical lectrical S Schematics chematics 3A Models
LINE LOAD 6A Models LINE LOAD
## 6A Models
> L Leakage eakage c current urrent d designation esignation V – Standard
C Current urrent R Rating ating 3 or 6A
A Accessories ccessories G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord
## Available Part Numbers ~~Available Part Numbers~~
|3VAQ3<br>3VAQ8F<br>3VAQ8FS<br>~~Available Part Numbers Numbers~~|6VAQ3<br>6VAQ8F<br>6VAQ8FS<br>~~Part Numbers Numbers~~|
|---|---|
_*IEC 60320-1 C14 inlet mates with C13 connector_
12
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **High Frequency Power Line Filter or Power Entry Module** _(continued)_
## AQ Series
## C Case ase S Styles tyles a and nd D Dimensions imensions
## 3VAQ3
## 6VAQ3
**==> picture [489 x 525] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.46 62.3 CL 1.66 ± .015 42.1 ± .38 2.572 65.3 CL<br>5.126 12.0 Min.<br> 4.14 12.0 Min.<br>130.0 304.8<br>105.1 304.8 5.327±.015 (5 places)<br>4.36 ± .015 135.3<br>111.4 ± .38 .515 #6-32<br> .515 13.08 #6-32 Thd. (2 places)<br>13.08 — oe / t .5 ± .01<br>#6-32 1.0 ± 0.1<br>#6-32 25.4 ± .25 (2 x) 12.7 ± .25<br>3.061 2.0 ± .01<br>1.98 _ FF — 77.8 a a 50.8 ± .25<br>40.1 .50 ± .02 .78<br>12.7 ± .5 19.8<br>nn = {f=<br>+____ — —<br>3VAQ8F 6VAQ8F<br> 5.96 6.457<br>152.0 164<br>5.68 ± .01<br>5.06 ± .015<br>44.3 ± .25<br>128.6 ± .38<br> 4.0 ± .01<br>2.35 ± .015 .90 102 ± .25<br> 59.6 ± .38 22.9<br>2.328 ± .01 1.125 ± .01 3.062<br>1.58 ±.015 .958 2.48 59 ± .35 28.6 ± .25 77.8<br>40 ± .38 24.3 63.0<br>Tabi | | [&=-<br>1! .411 | #6-32 aa t | .355 9.02 7 ref ro .354 ±.010 8.99 ± .25 ref & #6-32(6) inserts Ws .391 ± .01 9.93 ± .25 i<br>JE 10.4 ref (6) inserts 12.0 Min. a —_<br>12.0 Min. 305.0<br>305.0<br>2.576<br>1.62<br>65.4<br>41.2<br>yar .375 ± .125 — .375 ± .125 ae<br>a 9.53 ± 3.2 a ae J -= 9.53 ± 3.2 4<br>3VAQ8FS 6VAQ8FS<br>5.39 ± .015 7.125<br>136.9 ± .38 .172 181.0<br>1.058 4.37 6.347 ± .015<br>2.35 ± .015 26.9 161.2 ± .38<br> 59.6 ± .38 #6-32 4.0 ± .015<br>(6) inserts 101.55 ± .25<br>j .44<br>1.575 ± .015 — [j] se; 11.2 .958 _ 2.48 =<br>40.01 ± .38 24.3 63.0 2.33 ±.015 1.52 ± .01 3.07<br>59.0 ± .38 38.5 ± .25 77.8<br>°* SZ e E® Y<br>.411 #6-32<br>he 10.4 ref (6) inserts .364 1.12 ± .01 .391 ± .01<br>.375 ± .125 —— 9.53 ± 3.2 im~ 9.25 7 12.0 Min. 28.3 ± .25 Po 9.93 ± .25 tt<br>1.62 304.8<br>41.2<br>2.58<br>65.4<br>efae 12.0 Min. 305.0 160.0 6.30 | — .375 ± .125 9.53 ± 3.2 S+Pmn<br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
13
For email, phone or live chat, please go to **te.com/help**
**corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **High Frequency Power Line Filter or Power Entry Module** _(continued)_
## AQ Series
## R Recommended ecommended P Panel anel C Cutouts utouts
**==> picture [369 x 321] intentionally omitted <==**
**----- Start of picture text -----**<br>
.910 ± .005<br>23.11 ± .13 .235 ± .005 .855 ± .005<br>R 21.72 ± .13<br>5.969 ± .13<br>] —_- 7 ry<br>.620 ± .005<br>15.75 ± .13<br>1.295 ± .005<br>32.89 ± .13<br>— I s<br>P p .620 ± .005 Dia.<br>15.75 ± .13<br>ce De D D Data atataa<br>3VAQ 6VAQ<br>db db<br>100 100<br>90 90<br>80 80<br>70 70<br>60 60<br>50 50<br>40 40<br>30 30<br>20 20<br>10 10<br>0 0.01 0.1 1 10 100 1000 0 0.01 0.1 1 10 100 1000<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## P Performance erformance De D D Data atataa
## Typical Insertion Loss
Measured in closed 50 Ohm system
## 3VAQ 6VAQ
Common Mode / Asymmetrical (L-G) ~~D~~ ifferential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|****||||****|****|****|||||****||||****|****|****||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****<br>****|||****|****|****|****|****|****|****|****|****<br>****||
||||||||||||||||||||||
||||||||||||||||||||||
14
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **General Purpose RFI Filters for High Impedance Loads at Low Current**
## B Series
UL Recognized CSA Certified VDE Approved
**==> picture [169 x 67] intentionally omitted <==**
**----- Start of picture text -----**<br>
VB6<br>VB1 / EB1 VB3 / EB3<br>**----- End of picture text -----**<br>
## B S Series eries
- Small size & low cost
- General purpose
- Wide variety of termination options
- Meets low leakage current requirements of VDE portable equipment and non-patient medical equipment
## O Ordering rdering I Information nformation
10 E B 1 L Input Input / / O Output utput S Style tyle 1 – .250 [6.3] spade terminals 3 – Wire leads
## S Specifications pecifications
Maximum leakage current each Line to Ground:
|@ 120 VAC 60 Hz:<br>@250 VAC 50 Hz:|VB Models<br>.4 mA<br>.7 mA|EB Models<br>.21 mA<br>.36 mA|
|---|---|---|
|Hipot rating (one minute):<br>Line to Ground:||2250 VDC|
|Line to Line:||1450 VDC|
|Rated Voltage (max):||250 VAC|
|Operating Frequency:<br>Rated Current:||50/60 Hz<br>1 to 30A|
Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
- 6 – Threaded bolt
- B B S Series eries
> L Leakage eakage c current urrent d designation esignation E – Low leakage _(<0.5 mA)_ V – Standard
- C Current urrent R Rating ating 1, 2, 3, 5, 10, 20 or 30A
## E Electrical lectrical S Schematic chematic
**==> picture [166 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>**----- End of picture text -----**<br>
## Available Part Numbers
## Available Part Numbers Available vailable Part Numbersailable Part Numbersilable Part Numberslable Part Numbersable Part Numbersble Part Numbersle Part Numberse Part Numbers Part Numbers Part art Numbersrt Numberst Numbers Numbers Numbers umbersmbersbersersrss
|1VB1|1EB1|
|---|---|
|1VB3|1EB3|
|2VB1|2EB1|
|2VB3|2EB3|
|3VB1|3EB1|
|3VB3|3EB3|
|5VB1|5EB1|
|5VB3|5EB3|
|10VB1|10EB1|
|10VB3|10EB3|
|10VB6<br>20VB1<br>20VB6<br>30VB6|20EB1|
15
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **General Purpose RFI Filters for High Impedance/ Low Current** _(continued)_
## B Series
## C Case ase S Styles tyles
**==> picture [483 x 151] intentionally omitted <==**
**----- Start of picture text -----**<br>
B1 30VB6<br>E D B<br>E D B<br>2.00<br>50.8<br>E os A a C = A | C<br> <br> <br> <br> <br>**----- End of picture text -----**<br>
**==> picture [494 x 305] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|B3|C|Case|ase D|Dimensions|imensions|
|A|B|C|D|E|
|Part No.||
|Blue|Blue||||||
|Green/Yellow|1VB1, 1EB1,||||||
|E|D|B|—|o)|
|Brown|Brown|2VB1, 2EB1||||||
|1VB3, 1EB3,||||||
|2VB3, 2EB3||||||
|||—|©|re|
|=e|
|3VB1, 3EB1,||||||
||— ee|A|C|5VB1, 5EB1||||||
|||||3VB3, 3EB3,||||||
|||||5VB3, 5EB3||||||
||||||
|10VB1, 10EB1|
||||||
||||||
|10VB3, 10EB3|
||||||
|10VB6 & 20VB6||||||
|10VB6|
||||||
||||||
|20VB1, 20EB1|
||||||
|E|D|B||||||
|20VB6|
||||||
||||||
|30VB6|
||||||
|N|EM:|
**----- End of picture text -----**<br>
**==> picture [231 x 144] intentionally omitted <==**
**----- Start of picture text -----**<br>
10VB6 & 20VB6<br>E D B<br>= N EM: A <— C >|<br><br> <br> <br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
16
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **General Purpose RFI Filters for High Impedance/ Low Current** _(continued)_
## B Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
Measured in closed 50 Ohm system
## 1EB & 3EB
## 2EB, 5EB & 10EB
## 20EB
**==> picture [421 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db db<br>1009080 tHA 1009080 on|ot 1009080 CTTCT MtMt<br>6070 CCIE a 6070 |CCIE CI 6070<br>50 er eee 50 Et 50<br>40 aa i 40 [COI 40<br>30 et AI 30 eea 30<br>2010 —_ CLCt| 2010 — =, 2010<br>|<br>0 0.1 1 10 30 [CIEIE 0 0.1 1 10 30 0 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## 1VB
## 2VB
## 3VB
**==> picture [421 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db db<br>100 100 100<br>90 a 90 a 90 Cot ot<br>80 et 80 CIE Ce 80 CHAE Ce<br>70 | 70 | 70 CHIE oo<br>60 [COI 60 | 60 CHAE<br>50 [CO err 50 a 50 Us<br>40 of 40 [CO rr 40 a<br>30 aii 30 [ae 30 A<br>20 a _ 20 ra 20 :<br>10 10 10<br>0 0 0<br>0.1 1 10 30 0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## 20VB
## 10VB
**==> picture [264 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db<br>100 100<br>90 90<br>80 CIE 80 Et<br>70 | IE 70 |<br>60 60<br>50 HE 50 |:<br>40 40<br>3020 aps| 3020 oeet<br>10 10<br>0 0.1 1 10 30 LA 0 0.1 1 10 30 ea<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## 30VB
**==> picture [114 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db<br>100<br>90<br>80 Ct Tit<br>70 CHAE<br>60<br>50 CHAEeee<br>40<br>30 SH| at<br>20<br>10<br>0 0.1 1 10 30 CIE Co<br>Frequency in MHz<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
|****||****|****|****|****||
|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|
|****|||||||
||||||||
||||||||
|****|||||||
||||||||
||||||||
17
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Enhanced Differential Mode Performance K Series RFI Line Filters**
## DK Series
## UL Recognized CSA Certified VDE Approved
**==> picture [147 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
DK3<br>*3 O25 =<br>DK1<br>DK6<br>**----- End of picture text -----**<br>
## DK S Seriesriesiesess DK K S Seriesriesiesess Series eriesriesiesess
## DK S Seriesriesiesess
- Higher performance Line to Line attenuation than the K Series
- E version meets the low leakage current requirements of VDE portable equipment and non-patient care equipment
- V version features same high performance with more cost-effective design
## O Ordering rdering I Information nformation
## 10 E DK 3
- L I Input nput / / O Output utput S Style tyle 1 – .250 [6.3] spade terminals 3 – Wire leads
## S Specifications pecifications
Maximum leakage current each Line to Ground:
||VDK Models|EDK Models|
|---|---|---|
|@ 120 VAC 60 Hz:<br>@250 VAC 50 Hz:|.4 mA<br>.7 mA|.22 mA<br>.38 mA|
|Hipot rating (one minute):|||
|Line to Ground:<br>Line to Line:||2250 VDC<br>1450 VDC|
|Rated Voltage (max):||250 VAC|
|Operating Frequency:<br>Rated Current:||50/60 Hz<br>1 to 20A|
|Operating Ambient Temperature Range|||
|(at rated current Ir):||-10°C to +40°C|
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
- 6 – Threaded bolt
- D DK K S Series eries
> L Leakage eakage current current designation designation E – Low leakage _(<0.5 mA)_ V – Standard
C Current urrent R Rating ating 1, 3, 6, 10, or 20A
## E Electrical lectrical S Schematic chematic
**==> picture [180 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>**----- End of picture text -----**<br>
## Available Part Numbers
## Available Part Numbers Available vailable Part Numbersailable Part Numbersilable Part Numberslable Part Numbersable Part Numbersble Part Numbersle Part Numberse Part Numbers Part Numbers Part art Numbersrt Numberst Numbers Numbers Numbers umbersmbersbersersrss
|1VDK1|1EDK1|
|---|---|
|1VDK3|1EDK3|
|3VDK1|3EDK1|
|3VDK3|3EDK3|
|6VDK1|6EDK1|
|6VDK3|6EDK3|
|10VDK1|10EDK1|
|10VDK3|10EDK3|
|20VDK1|20EDK1|
|20VDK6||
18
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Enhanced Differential Mode K Series RFI Power Line Filters** _(continued)_
## DK Series
## C Case ase S Styles tyles
## VDK1 / EDK1
## 20VDK6
**==> picture [222 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
E C<br>D<br>B<br>t a a! |<br>A<br>es<br><br> <br> <br> <br>**----- End of picture text -----**<br>
**==> picture [240 x 105] intentionally omitted <==**
**----- Start of picture text -----**<br>
E D B<br>ail | he i<br>A _ C<br><br> <br> <br>**----- End of picture text -----**<br>
## VDK3 / EDK3
E C Case Dimensions D ~~_~~ 77 ~~Case Dimensions~~ A B C D E Blue Blue Part No. __ B ** ** Brown Brown 1VDK1, 1EDK1 _ _ — ~~* ele~~ ** ** 1VDK3, 1EDK3 ~~—~~ A es Green/ © Oo ~~r~~ _ _ ~~**e**~~ _ _ ~~—~~ Yellow EN ~~4 B~~ 3VDK1, 3EDK1, ** ** 6VDK1, 6EDK1 _ _ __ __ 3VDK3, 3EDK3, ** ** 6VDK3, 6EDK3 _ _ 10VDK1, ** ** 20VDK1 / 20EDK1 10EDK1 _ _ 10VDK3, ** ** ~~i~~ 10EDK3 _ _ 20VDK1, ** ** 20EDK1 _ _ E D : B al ** ** 20VDK6 _ _
**==> picture [241 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
E D : B al<br>| Tk<br>~<br>— A J b C a<br><br> <br> <br> <br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
19
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Enhanced Differential Mode K Series RFI Power Line Filters** _(continued)_
## DK Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [493 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 & 3VDK 6, 10, 20VDK 1 & 3EDK 6, 10, 20EDK<br>db db db db<br>10090 | ee 10090 | 10090 Tt 10090 | ee<br>80 80 80 80<br>70 70 70 70<br>60 SHH 60 HE 60 Se 60<br>50 50 50 50<br>40 40 40 40<br>30 7200BS 30 SALert | Ti | 30 aeA 30 eer<br>20 20 20 20<br>10 HHH 10 10 10 |<br>0 LT 0.1 1 10 30 TI 0 0.1 1 10 30 ReLT TiTTT 0 0.1 1 10 30 A 0 0.1 1 10 30 ee<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
|****||****|****|****|****|||****||****|****|****|****||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****||****|****|****|****|****|****|****|
|****||||||||****|||||||
||||||||||||||||
||||||||||||||||
|****|||||||||||||||
||||||||||||||||
||||||||||||||||
20
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **PC Board Mountable General Purpose RFI Filters**
## EBP, EDP & EOP Series
UL Recognized* CSA Certified* VDE Approved*
**==> picture [43 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
1EDP / 1EOP<br>**----- End of picture text -----**<br>
**==> picture [18 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
1EBP<br>**----- End of picture text -----**<br>
## E EBP BP S Series eries
- General purpose
- Low leakage current
- Cost-effective
- Compact size
## E EDP DP SP S S Series eriesriesiesess
## E EDP DP SP S S Series eriesriesiesess
- Enhanced differential mode performance
- Low leakage current
- Cost-effective
## E EOP OP S Series eries
- General purpose
- Low leakage current
- Cost-effective
## O Ordering rdering I Information nformation
6 EDP EBP Series EBP Series Compact Size E EDP DP S Series eries Enhanced Performance EOP Series EOP General Performance Series C Current urrent R Rating ating 1, 3, 6 or 10A
_*EBP models are approved to VDE standards only_
## S Specifications pecifications
Maximum leakage current each Line to Ground:
EDP/EOP EBP @ 120 VAC 60 Hz: .22 mA .13 mA @250 VAC 50 Hz: .38 mA .21 mA Hipot rating (one minute): Line to Ground: 2250 VDC Line to Line: 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 1 to 10A
Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
## E Electrical lectrical S Schematic chematic
## EBP
LINE LOAD T ~~a~~ C.W ~~AAL~~ LINE LOAD
## EDP & EOP
## A Available vailable P Part art N Numbers umbers
|1EBP|3EBP|
|---|---|
|1EDP|1EOP|
|3EDP|3EOP|
|6EDP|6EOP|
|10EDP|10EOP|
21
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **PC Board Mountable General Purpose RFI Filters** _(continued)_
## EBP, EDP, EOP Series
**==> picture [493 x 552] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles C Case ase D Dimensions imensions<br>EBP<br>A A B C<br>Part No.<br> <br> <br>ry —| EBP<br> <br>C<br> <br>EDP<br> <br> <br>.35 Max. EOP <br>8.97<br>L |, —_____<br>LINE<br>y .787<br>B 20.00<br>.394<br>10.00<br>LOAD<br>.098 2.5 | . 15.0 590 get .098 2.5<br><br> <br>P Performance erformance D Data ata<br>EDP / EOP<br>hk A Typical Insertion Loss<br>ft Measured in closed 50 Ohm system<br>C<br>1EBP 3EBP<br>os 8.97 + .35 Max. 100db 100db<br>90 90<br>80 80<br>as 70 AHI HHI 70 EEE HIE EHH<br>60 60<br>LINE LOAD .31 ± .02 50 50<br>= 7.87 ± .5 40 a 40<br>30 30<br>20 20<br>.591 ± .006 10 10<br>B 15.00 ± .15 0 0<br>0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>.295 ± .006<br>7.50 ± .15<br>.689 ± .006<br>17.50 ± .15<br>.36 ± .02 Common Mode / Asymmetrical (L-G)<br>9.10 ± .5<br>1 ——<br>Differential Mode / Symmetrical (L-L)<br><br> <br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
22
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
**PC Board Mountable General Purpose RFI Filters** _(continued)_
## EBP, EDP & EOP Series
## P Performance erformance D Data ata _(continued)_
## Typical Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## 1EDP 3EDP
## 6EDP
## 10EDP
**==> picture [493 x 118] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db db db<br>100 100 100 100<br>90 90 90 90<br>80 80 80 80<br>70 | 70 | 70 CoCeomil_ ei 70 il CHTl<br>60 a 60 | 60 | CI 60 tl [|<br>50 FOEaw HE~~ 50 [CMIEHH HHT 50 EACIE 50 il it—~:<br>40 aa 40 | ft | 40 ll pa 40 (i<br>30 30 30 30<br>20 20 20 20<br>10 10 10 10<br>0 0.1 1 10 30 Comi oat _ 0 0.1 1 10 30 eee=ango il 0 0.1 1 10 30 [CIA—arr 0 0.1 1 10 30 PCmr .000l||<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>1EOP 3EOP 6EOP 10EOP<br>**----- End of picture text -----**<br>
## 6EOP
## 10EOP
**==> picture [492 x 97] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db db db<br>100 100 100 100<br>90 0 | 90 | || 90 Too TC o_] 90 i<br>80 80 80 80<br>70 SIS 70 ETI tie = 70 EER HH 70 EHR HE<br>60 0 60 | 60 EE | 60 aE<br>50 —_ 50 | al 50 CE A 50 aE<br>40 tt 40 eT N 40 COO Zea 40 [Ce<br>30 il 30 ae ll PT 30 ee 30 —Le<br>20 20 20 20<br>10 10 10 10<br>0 0.1 1 10 30 A 0 0.1 1 10 30 A 0 0.1 1 10 30 CoirI 0 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|****||****|****|****|****|||****||||****|****|****|****||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****||****||****|****|****||****|****|****|
|****||||||||****|||||||||
||||||||||||||||||
||||||||||||||||||
|****||||||||****|||||||||
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
||||||||||||****||||||
|****||||||||****|****|****|****|****|****|****|****|****|
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
23
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Compact and Cost-effective Dual Stage RFI Power Line Filters**
## EMC Series
UL Recognized CSA Certified VDE Approved
**==> picture [151 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
EMC6 EMC1<br>**----- End of picture text -----**<br>
## E EMC MC S Series eries
- Compact dual stage filter series
- Cost-effective design
- Current rating up to 30A
- High differential mode attenuation in the lower frequency range
- High common mode performance
- Suitable for switching mode power supplies
## S Specifications pecifications
|S<br>pecifications<br>ecifications<br>cifications<br>ifications<br>fications<br>cations<br>ations<br>tions<br>ions<br>ons<br>ns<br>s<br>Specifications|||
|---|---|---|
|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:||
||3, 6, 10A|15, 20, 30A|
|@ 120 VAC 60 Hz:|.21 mA|.73 mA|
|@250 VAC 50 Hz:|.43 mA|1.52 mA|
|Hipot rating (one minute):|||
|Line to Ground:||2250 VDC|
|Line to Line:||1450 VDC|
|Rated Voltage (max):||250 VAC|
|Operating Frequency:||50/60 Hz|
|Rated Current:||3 to 30A|
|Operating Ambient Temperature Range|||
|(at rated current Ir):||-10°C to +40°C|
|In an ambient temperature (Ta) higher than +40°C|||
|the maximum operating current (Io) is calculated as|the maximum operating current (Io) is calculated as<br>follows: Io|the maximum operating current (Io) is calculated as<br> = Ir (85-Ta)/45|
## O Ordering rdering I Information nformation
## 10 EMC 1
- L C Case ase Styles Styles 1 – .250 [6.3] spade terminals 3 – Wire leads
## E Electrical lectrical S Schematic chematic
**==> picture [226 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>**----- End of picture text -----**<br>
- 6 – Threaded bolt
- E EMC MC S Series eries
> C Current urrent R Rating ating 3, 6, 10, 15, 20 or 30A
## A Available vailable P Part art N Numbers umbers
|3EMC1<br>6EMC1<br>10EMC1<br>15EMC1<br>20EMC1<br>3EMC3<br>6EMC3|10EMC3<br>15EMC3<br>10EMC6<br>15EMC6<br>20EMC6<br>30EMC6|
|---|---|
24
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Compact and Cost-effective Dual Stage RFI Power Line Filters** _(continued)_
## EMC Series
**==> picture [486 x 391] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles<br>EMC1 30EMC6<br>TH Ir ai<br>B<br>E D B<br>aohh<br>a<br>i. | af b=<br>D C<br>E<br>A A C __<br> <br> <br> <br> <br>EMC3 C Case ase D Dimensions imensions<br>A B C D E<br>Green/ Part No.<br>Yellow <br> <br>Brown Brown 3EMC1 <br>B<br> <br>6EMC1<br> <br>Blue Blue<br> <br>10EMC1<br>A <br>| D a C _<br>E 15EMC1 <br>20EMC1 <br> <br> 3EMC3<br> <br>**----- End of picture text -----**<br>
|||||||||Part No.|A<br>|B<br>|C<br>|D<br>|E<br>|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|~~a ~~|||C<br> ~~_~~|||B||3EMC1<br>6EMC1<br>10EMC1<br>15EMC1|****<br>__<br>****<br>__<br>****<br>__<br>****|****<br>__<br>****<br>__<br>****<br>__<br>****|****<br>__<br>****<br>__<br>****<br>__<br>****|****<br>__<br>****<br>__<br>****<br>__<br>****|****<br>__<br>****<br>__<br>****<br>__<br>****|
|||||||||20EMC1|__|__|__|__|__|
|<br>|<br>|||||||3EMC3|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|||||||||6EMC3|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|||||||||10EMC3|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|||||||||15EMC3|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|©||||B<br> ~~7 a~~||||10EMC6<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>15EMC6<br>****<br>****<br>****<br>****<br>****<br>~~a~~||||||
|||||||||20EMC6|__|__|__|__|__|
|||C||||||30EMC6|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
## EMC6
**==> picture [231 x 61] intentionally omitted <==**
**----- Start of picture text -----**<br>
D C<br>E<br>A<br><br> <br> <br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
25
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**Compact and Cost-effective Dual Stage RFI Power Line Filters** _(continued)_
## EMC Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [493 x 236] intentionally omitted <==**
**----- Start of picture text -----**<br>
3EMC 6EMC 10EMC 15EMC<br>db db db db<br>100 100 100 100<br>90 90 90 90<br>80 aA 80 80 AT 80<br>70 i~ 70 y A 70 70 7.<br>60 fo 60 Yen 60 y, Aline 60 ill |<br>50 50 50 50<br>7A ss dt (i nan ZL<br>40 i 40 40 7 40 Ze 40 ZA<br>3020 >7 AHAH00 3020 SiaACCACC eeeCeri 3020 pTtAC A L 3020 pA7I/F<br>100 AEPIC) 100 100 08000 100 800ee<br>0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>20EMC 30EMC<br>db db<br>100 100<br>90 90<br>80 80<br>70 70 Common Mode / Asymmetrical (L-G)<br>40605030 aCEANAA an diBN 40605030 ZOTLAAaA Hohs Differential Mode / Symmetrical (L-L)<br>20 20<br>100 0.1 1 10 30 ASEHPm) 100 0.1 1 10 30 EtCe<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|****|||****|****|****|****|****||||****|||****|****|****|****|****|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****||****|****|****|****|****|****|****||****|****||****|****|****|****|****|****|****|
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
26
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Dual Stage RFI Power Line Filters for Switching Mode Power Supplies**
## EP / VP Series
UL Recognized CSA Certified VDE Approved
**==> picture [197 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
EP7 / VP7<br>EP1 / VP1<br>EP3 / VP3<br>**----- End of picture text -----**<br>
## E EP P & & V VP P S Series eries
- Dual stage filter offers high insertion loss
- Well suited for meeting CISPR 22 A and FCC Part 15J, Class B
- EP model meets very low leakage current requirements
- 7A and 12A versions offer optimum package size
## O Ordering rdering I Information nformation
## 3 EP 7 M
~~L~~ Suffix Suffix M – Metric inserts _(style 7 only)_ Omit for standard or none I Input nput / / O Output utput S Style tyle 1 – .250 [6.3] spade terminals 3 – Wire leads
## S Specifications pecifications
## Maximum leakage current each Line to Ground:
|@ 120 VAC 60 Hz:<br>@250 VAC 50 Hz:<br>Hipot rating (one minute):<br>Line to Ground:<br>Line to Line:<br>Rated Voltage (max):|VP Models<br>.73 mA<br>1.27 mA|EP Models<br>.21 mA<br>.36 mA<br>2250 VDC<br>1450 VDC<br>250 VAC|
|---|---|---|
|Operating Frequency:||50/60 Hz|
|Rated Current:||3 to 20A|
Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
## A Available vailable P Part art N Numbers umbers
6 – Threaded bolt
7 – IEC inlet* _(line side)_ .250 [6.3] spade terminals _(load side)_
> E EP P / / V VP P S Series eries EP – Low leakage _(<0.5 mA)_ VP – Standard _(20A only)_
|3EP1<br>3EP3<br>3EP7<br>3EP7M<br>6EP1<br>6EP3<br>7EP1<br>7EP3|10EP1<br>10EP3<br>12EP1<br>12EP3<br>20EP1<br>20EP6<br>20VP1<br>20VP6|
|---|---|
C Current urrent R Rating ating 3, 6, 7, 10, 12 or 20A
## E Electrical lectrical S Schematic chematic
LINE
LOAD
A Accessories ccessories G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord
_*IEC 60320-1 C14 inlet mates with C13 connector_
27
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Dual Stage RFI Filters for Switching Power Supplies** _(continued)_
## EP / VP Series
## C Case ase S Styles tyles
**==> picture [216 x 376] intentionally omitted <==**
**----- Start of picture text -----**<br>
EP1 / VP1 (1-15A)<br>B<br>| IL fo)<br>ae D<br>E<br>== A C<br>on<br><br> <br> <br> <br>20EP1 / VP1<br>B<br>if D -o |<br>E<br>A C<br>= J<br><br> <br> <br> <br>**----- End of picture text -----**<br>
## EP7 & EP7M
**==> picture [171 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
Tapped insert<br>D B<br>Ei<br>A ft E<br>. ns C<br>**----- End of picture text -----**<br>
- __ __
## 20EP6 / VP6
**==> picture [240 x 110] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>D<br>E<br>_ A =! To C<br><br> <br> <br>**----- End of picture text -----**<br>
## EP3
## R Recommended ecommended P Panel anel C Cutout utout
**==> picture [241 x 136] intentionally omitted <==**
**----- Start of picture text -----**<br>
E C<br>D<br>4<br>Brown Brown<br>Blue Blue B<br>_—_— Vaan<br>. —? © Oo<br>A Green/<br>Yellow<br><br> <br> <br>**----- End of picture text -----**<br>
**==> picture [136 x 129] intentionally omitted <==**
**----- Start of picture text -----**<br>
. .235 5.96 R .157 . Dia. (2)<br>3.98<br>.910<br>23.11<br>1.295<br>|<br>EE 32.89<br>1.575<br>40.01<br><br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
28
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Dual Stage RFI Filters for Switching Power Supplies** _(continued)_
## EP / VP Series
## C Case ase D Dimensions imensions
## Typical Insertion Loss _(continued)_
**==> picture [241 x 319] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|A|B|C|D|E|
|Part No.||
||||||
||||||
|3EP1|
||||||
||||||
|3EP3|
||||||
||||||[]|
|3EP7/7M|
||||||[]|
||||||
|6EP1|
||||||
||||||
|6EP3|
||||||
||||||
|7EP1|
||||||
||||||
|7EP3|
||||||
||||||
|10EP1|
||||||
||||||
|10EP3|
||||||
||||||
|12EP1|
||||||
||||||
|12EP3|
||||||
||||||
|20EP1/VP1|
||||||
||||||
|20EP6/VP6|
||||||
||||
**----- End of picture text -----**<br>
**==> picture [240 x 214] intentionally omitted <==**
**----- Start of picture text -----**<br>
12EP 20EP<br>db db<br>100 100<br>90 90<br>80 80<br>70 70<br>60 60<br>50 50<br>40 40<br>30 30<br>20 20<br>10 10<br>0 0.01 0.1 1 10 30 0 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>20VP<br>db<br>100<br>90<br>80 Common Mode /<br>70 Asymmetrical (L-G)<br>6050 Differential Mode /<br>40 Symmetrical (L-L)<br>30<br>20<br>10<br>0<br>0.01 0.1 1 10 30<br>Frequency in MHz<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
**==> picture [493 x 320] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||
|20EP1/VP1|||||||||||||||
|||||||
|20EP6/VP6|
|||||||||||||||
||||
||||||||||
|P|Performance|erformance D|Data|ata||||||||||
|Typical Insertion Loss||||||||||
|Measured in closed 50 Ohm system||||||||||
|3EP|6EP|
|db|db|
|1009080|COMCO|Cn|1009080|C0|aul ment|||||||||||
|70|A|—|70|
|60|CONIA|60|Co|EES||.|A|Differential Mode / Symmetrical (Line to Line)|
|50|COW|AAI|CC|50|CH|CCC|
|40|COICOA|ZCIASSOCo|40|CH/|TMM=|~Mp|||
|3020|COAACIZCICIE|C|onC|2CI|3020|Coe ZA|CoiloI||||||||||
|10|AAI|CO|CI|10|Coil||
|0|0.01 0.1 1 10 30|ConCIE|Frequency in MHz|FieCo|0|0.01 0.1 1 10 30|J|ft|:|Frequency in MHz||||||||||
|7EP|10EP||||||||||
|db|db|
|100|100||||||||||
|90|COICO|90|
|80|COASS|80|=||||||||||
|6070|HELEN|6070|ICING||||||||||
|50|50|
|4030|a)na|ee|4030|CEMCCCo||||
|20|20|
|10|(ena|10|aot||||||||||
|0|0.01 0.1 1 10 30|Cem|conoir|0|Ameri|0.01 0.1 1 10 30|aa|Pb|sssssssssssC|
|Frequency in MHz|Frequency in MHz|
**----- End of picture text -----**<br>
29
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Single Phase Power Line Filter for Frequency Converters**
## FC Series
## UL Recognized
## F FC C S Series eries
- Designed for frequency inverters and variable speed motor drives
- Suitable for electronically noisy environments
- Protects programmable logic controllers from RF noise on the AC power line
- Side flanges for easy mounting
- Touch safe terminals provide easy connections and prevent inadvertent contact for safety in the most demanding applications
## O Ordering rdering I Information nformation
36 FC 10 B ~~L~~ S Suffi u “we ffix B – Single stage Omit for dual stage I Input nput / / O Output utput S Style tyle 10 – DIN type terminal block FC Series FC Series C Current urrent R Rating ating 6, 12, 16, 25, 36 or 50A
## S Specifications pecifications
|S<br>pecifications<br>ecifications<br>cifications<br>ifications<br>fications<br>cations<br>ations<br>tions<br>ions<br>ons<br>ns<br>s<br>Specifications|||
|---|---|---|
|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:||
||B suffix|no suffix|
|@ 120 VAC 60 Hz:<br>@250 VAC 50 Hz:|3.9 mA<br>7.0 mA|3.8 mA<br>6.7 mA|
|Hipot rating (one minute):<br>Line to Ground:||2250 VDC|
|Line to Line:||1450 VDC|
|Rated Voltage (max):<br>Operating Frequency:||250 VAC<br>50/60 Hz|
|Rated Current:||6 to 50A|
|Operating Ambient Temperature Range|||
|(at rated current Ir):<br>-10°C to +40°C<br>In an ambient temperature (Ta) higher than +40°C|||
|the maximum operating current (Io) is calculated as|the maximum operating current (Io) is calculated as<br>follows: Io|the maximum operating current (Io) is calculated as<br> = Ir (85-Ta)/45|
## E Electrical lectrical S Schematics chematics
## FC10
**==> picture [240 x 82] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>1<br>2<br>1<br>“15 a : C ian — It”<br> <br> <br>**----- End of picture text -----**<br>
## A Available vailable P Part art N Numbers umbers
|6FC10<br>12FC10<br>16FC10<br>25FC10<br>36FC10<br>50FC10|12FC10B<br>16FC10B<br>25FC10B<br>36FC10B<br>50FC10B|
|---|---|
## FC10B
LINE LOAD
30
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Single Phase Filter for Frequency Converters** _(continued)_
## FC Series
## C Case ase Sse Se S S Styles tylesyleslesess
**==> picture [494 x 186] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase Sse Se S S Styles tylesyleslesess C Case ase D Dimensions imensions<br>A B C D E F<br>FC10 / FC10B (6, 12, 16A) Part No. <br> <br>6FC10<br> <br>[ a 12FC10/10B es <br>B © ma il a D 16FC10/10B <br>25, 36, 50 <br>FC10/10B <br>| E |<br>C F<br>E<br>This hole indicates A<br>the "Line" side and<br>may be on either flange.<br>**----- End of picture text -----**<br>
FC10 / FC10B (6, 12, 16A)
**==> picture [237 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
<br> <br> <br> <br>**----- End of picture text -----**<br>
## FC10 / FC10B (25, 36, 50A )
**==> picture [233 x 219] intentionally omitted <==**
**----- Start of picture text -----**<br>
This hole indicates the "Line" side<br>and may be on either flange.<br>f BU<br>B D<br>- C ; F |<br>E<br>A<br><br> <br> <br> <br>**----- End of picture text -----**<br>
31
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Single Phase Filter for Frequency Converters** _(continued)_
## FC Series
## Performance Data
## Typical Insertion Loss
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
Measured in closed 50 Ohm system
**==> picture [418 x 323] intentionally omitted <==**
**----- Start of picture text -----**<br>
6FC10 12FC10 16FC10<br>db db db<br>100 100 100<br>90 90 90<br>80 80 80<br>70 70 70<br>60 60 60<br>50 50 50<br>40 40 40<br>30 30 30<br>20 20 20<br>10 10 10<br>0 A 0.01 0.1 1 10 30 0 0.01 0.1 1 10 30 a 0 0.01 0.1 1 10 30 AG<br>Frequency in MHz Frequency in MHz Frequency in MHz<br>25FC10 36, 50FC10 12, 16FC10B<br>db db db<br>100 100 100<br>90 90 90<br>80 80 80<br>70 70 70<br>60 60 60<br>50 50 50<br>40 40 40<br>30 30 30<br>20 20 20<br>10 10 10<br>0 Al 0.01 0.1 1 10 30 0 0.01 0.1 1 10 30 wi 0 0.01 0.1 1 10 30 Ae<br>Frequency in MHz Frequency in MHz Frequency in MHz<br>25FC10B 36FC10B 50FC10B<br>db db db<br>100 100 100<br>90 90 90<br>80 80 80<br>70 70 70<br>60 60 60<br>50 50 50<br>40 40 40<br>30 30 30<br>20 20 20<br>10 10 10<br>0 0.01 0.1 1 10 30 Ail 0 ail 0.01 0.1 1 10 30 0 0.01 0.1 1 10 30 dit<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
**==> picture [115 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0 dit<br>0.01 0.1 1 10 30<br>Frequency in MHz<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
||||****|****|****|****|****|||||||****|****|****|****|****|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****||****|****|****|****|****|****|****||****|****||****|****|****|****|****|****|****|
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
32
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Differential Mode Filter for Fluorescent Lighting Applications**
## FL Series
## UL Listed
## F FL L S Series eries
- Specifically designed for fluorescent lights
- Suitable for industrial environments
- UL Listed for aftermarket installation
## O Ordering rdering I Information nformation
3 FL 3 ~~L~~ _, Input t / / O Output utput Styl Style nput 3 – Wire leads / Output Style F FL L S Series eries C Current urrent R Rating ating 3 – 3.9A
## S Specifications pecifications
Maximum leakage current each Line to Ground:
@ 125 VAC 60 Hz: 3.0 mA @280 VAC 50 Hz: 6.0 mA Hipot rating (one minute): Line to Ground: 1560 VAC Line to Line: 1560 VAC Rated Voltage: 125/280 VAC Operating Frequency: 50/60 Hz Rated Current: 3.9 A
Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
## E Electrical lectrical S Schematic chematic
**==> picture [150 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>**----- End of picture text -----**<br>
## A Available vailable P Part art N Number umber
3FL3
33
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Differential Mode Filter for Fluorescent Lighting Applications** _(continued)_
## FL Series
## C Case ase S Styles tyles
**==> picture [241 x 166] intentionally omitted <==**
**----- Start of picture text -----**<br>
[| C D<br>0.44<br>11.18<br>B<br>0.44<br>177.8 i 7.0 E<br>Min.<br>(4 Wires)<br>Strip<br>0.50 {<br>a 12.7<br>(Typ)<br>Jo A r<br>18 AWG (4X)<br>Load<br>Line<br>**----- End of picture text -----**<br>
**==> picture [240 x 65] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase D Dimensions imensions<br>A B C D E<br>Part No. <br> <br> <br>Bn 3FL3<br> <br>**----- End of picture text -----**<br>
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
## 3FL3
**==> picture [365 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db<br>10090 i<br>8070 ||<br>60 | Differential Mode / Symmetrical (L-L)<br>4050 otFy a|<br>30<br>20<br>10 eee<br>0 = Se |<br>0.1 1 10 30<br>Frequency in MHz<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Differential Mode / Symmetrical (Line to Line)
||||****|****|****|||
|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|
|||||||||
34
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **High Performance RFI Filters for Switching Power Supplies**
## G Series
## UL Recognized CSA Certified VDE Approved WE
**==> picture [171 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
10EG1 / 10VG1<br>ee b q=<br>6EG1 / 6VG1<br>**----- End of picture text -----**<br>
## G G S Series eries
- Designed to provide excellent attenuation for most digital electronics equipment
- Broad frequency range of performance from 20kHz to 30MHz
- Size and cost-effective solution
- Designed to help comply with EN55022 Level A and FCC Part 15J Class B
## O Ordering rdering I Information nformation
10 E G 1 ~~L~~ Input Input / Output / Output Style Style 1 – .250 [6.3] spade terminals
> G G S Series eries
> L Leakage eakage c current urrent d designation esignation E – Low leakage _(<0.5 mA)_ V – Standard
## S Specifications pecifications
Maximum leakage current each Line to Ground:
||EG Models|VG Models|
|---|---|---|
|@ 120 VAC 60 Hz:<br>@250 VAC 50 Hz:|.30 mA<br>.50 mA|1.2 mA<br>2.0 mA|
|Hipot rating (one minute):<br>Line to Ground:||2250 VDC|
|Line to Line:||1450 VDC|
|Rated Voltage (max):||250 VAC|
|Operating Frequency:||50/60 Hz|
|Rated Current:||6 & 10A|
|Operating Ambient Temperature Range|||
|(at rated current Ir):<br>-10°C to +40°C<br>In an ambient temperature (Ta) higher than +40°C<br>the maximum operating current (Io) is calculated as<br>follows: Io = Ir (85-Ta)/45<br>~~—_—_—~~|||
## E Electrical lectrical S Schematics chematics
## 6EG1 & 6VG1
LINE LOAD
C Current urrent R Rating ating 6 or 10A
## A Available vailable P Part art N Numbers umbers
|6EG1|6VG1|
|---|---|
|10EG1|10VG1|
## 10EG1 & 10VG1
LINE LOAD
35
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **High Performance RFI Filters for Switching Power Supplies** _(continued)_
## G Series
**==> picture [241 x 190] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles<br>B<br>6 | = |<br>D<br>C<br>E<br>Ke = A a<br><br> <br> <br> <br>**----- End of picture text -----**<br>
**==> picture [234 x 91] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase D Dimensions imensions<br>A B C D E<br>Part No. — <br> <br>6EG1/VG1<br> <br> <br>10EG1/VG1<br> <br>**----- End of picture text -----**<br>
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
**==> picture [493 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
6EG1 6VG1 10EG1 10VG1<br>db db db db<br>100 100 100 100<br>90 90 90 90<br>80 no 80 amet 80 NAH 80 ot<br>70 70 70 70<br>60 60 60 60<br>50 Hans 50 Hit ia et 50 50<br>40 fireet) 40 CHAE 40 40<br>30 30 30 30<br>20 ST 20 Coa TEP 20 20<br>10 10 10 10<br>0 i“ | 0 a 00 0 0 :<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|****||||****|****|****|****|||||****||||****|****|****|****||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****||****|****|****|****|****|****|****|****||****|****||****|****|****|****|****|****|****|****|
|****||||||||||||****|||||||||||
||||||||||||||||||||||||
||||||||||||||||||||||||
|****||||||||||||****|||||||||||
||||||||||||||||||||||||
||||||||||||||||||||||||
36
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Highest Performance RFI Filters for Medical Equipment**
## HQ Series
UL Recognized CSA Certified VDE Approved
**==> picture [132 x 80] intentionally omitted <==**
**----- Start of picture text -----**<br>
3EHQ3<br>6EHQ8<br>3EHQ1<br>**----- End of picture text -----**<br>
## H H@ Q S Series eries
- Designed to provide the highest available attenuation of RFI noise in the frequency range from 10kHz to 30MHz for low leakage current applications
- Size and cost-effective
## O Ordering rdering I Information nformation
## S Specifications pecifications
Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz: 2 A @250 VAC 50 Hz: 5 A Hipot rating (one minute): Line to Ground: 2250 VDC Line to Line: 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 & 6A
- Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C
- the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
## 6 E HQ 8 M
L Suffix Suffix M – Metric inserts _(style 8 only)_ Omit for standard or none I Input nput / / O Output utput S Style tyle 1 – .250 [6.3] spade terminals 3 – Wire leads 8 – IEC inlet* _(line side)_ Wire leads _(load side)_
## Available Part Numbersvailable Part Numbersailable Part Numbersilable Part Numberslable Part Numbersable Part Numbersble Part Numbersle Part Numberse Part Numbers Part Numbersart Numbersrt Numberst Numbers Numbersumbersmbersbersersrss Available Part Numbers
## Available Part Numbersvailable Part Numbersailable Part Numbersilable Part Numberslable Part Numbersable Part Numbersble Part Numbersle Part Numberse Part Numbers Part Numbersart Numbersrt Numberst Numbers Numbersumbersmbersbersersrss
|3EHQ1<br>3EHQ3<br>3EHQ8<br>3EHQ8M|6EHQ1<br>6EHQ3<br>6EHQ8<br>3EHQ8M|
|---|---|
A Accessories ccessories G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord
> H HQ Q S Series eries Leakage current designation Leakage E – Low leakage current designation _(<0.5 mA)_ Current Rating Current Rating 3 or 6A
_*IEC 60320-1 C14 inlet mates with C13 connector_
37
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Highest Performance RFI Filters for Medical Equipment** _(continued)_
## HQ Series
**==> picture [477 x 579] intentionally omitted <==**
**----- Start of picture text -----**<br>
E Electrical lectrical S Schematics chematics 3EHQ8 & 3EHQ8M<br>Tapped insert<br>3EHQ<br>Brown<br>LINE LOAD<br>Grn/Yel<br>Blue D B<br>A E<br>at c o=:t, | ecae<br>C<br>6EHQ — | ty<br>LINE LOAD<br><br>Oo CC 4 C + | <br> <br> <br> <br>C Case ase S Styles tyles<br>6EHQ8 & 6EHQ8M<br>HQ1<br>Tapped inserts<br>3A Models<br>ail |e _— ) [ff] C<br>B 0.63 Ref<br>16.0<br>D C E D<br>E A<br>=] A =- 6A Models oe<br>Grn/Yel<br>B<br>Blue Brown<br>a<br>B<br>= C | _<br><br><br> <br> <br> <br> <br>HQ3<br>3A Models<br>Blue Blue<br>Blue<br>Grn/Yel<br>Grn/Yel B<br>Brown Brown<br>Brown<br>A =- C<br>D 6A Models<br>==! E BI<br>Blue<br>B<br>Grn/Yel Brown<br>e l<br>C “3<br><br> <br> <br>**----- End of picture text -----**<br>
38
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Highest Performance RFI Filters for Medical Equipment** _(continued)_
## HQ Series
## R Recommended ecommended P Panel anel C Cutout utout
**==> picture [115 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
.235 .157<br>5.96 R 3.98 Dia. (2)<br>.910<br>23.11<br>1.295<br>32.89<br>1.575<br>= 40.01<br><br>**----- End of picture text -----**<br>
## C Case ase D Dimensions imensions
|Part No.<br>A<br>B<br>C<br>D<br>E<br><br><br><br><br>__<br><br>3EHQ1<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>3EHQ3<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>3EHQ8,<br>3EHQ8M<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>6EHQ1<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>6EHQ3<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>6EHQ8,<br>6EHQ8M<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>~~re~~|
|---|
__
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
3EHQ 6EHQ
**==> picture [246 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db<br>100 100<br>90 90<br>80 80<br>70 70<br>60 60<br>50 50<br>40 40<br>30 30<br>20 20<br>10 10<br>0 0<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|****||||****|****|****|****|****|||||****||||****|****|****|****|****||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****||||****|****|****|****|****||||****|****||||****|****|****|****|****|||
|||||<br>|||||||||||||<br>||||||||
|||||<br>|||||||||||||<br>||||||||
39
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **High Performance RFI Power Line Filters for Medical Equipment**
## HT Series
UL Recognized CSA Certified VDE Approved
**==> picture [172 x 83] intentionally omitted <==**
**----- Start of picture text -----**<br>
6EHT3<br>' 6EHT7<br>6EHT1<br>**----- End of picture text -----**<br>
## S Specifications pecifications
## H HT T S Series eries
- Designed to provide significant attenuation of RFI noise in the frequency range from 10kHz to 30MHz
Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: 2 A @250 VAC 50 Hz: 5 A Hipot rating (one minute): Line to Ground: 2250 VDC Line to Line: 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 to 15A
- Size and cost-effective
Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
## O Ordering rdering I Information nformation
6 E HT 7 M Available Part Numbers S Suffix uffix 3EHT1 6EHT7 M – Metric inserts _(style 7 only)_ Omit for standard or none 3EHT3 6EHT7M 3EHT7 10EHT1 | I Input nput / / O Output utput S Style tyle Available 3EHT7M Part Numbers 10EHT3 1 – .250 [6.3] spade terminals 6EHT1 15EHT1 3 – Wire leads 6EHT3 15EHT6 6 – Threaded bolt 7 – IEC inlet* _(line side)_ .250 [6.3] spade terminals A Accessories ccessoriescessoriesessoriesssoriessoriesoriesriesiesess _(load side)_ GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord H HT T Series Series GA400 Leakage current designation SL) Leakage E – Low leakage current designation _(<0.5 mA)_ a) eZ» C Current urrent Rating EP Ly} Rating we OG, 3, 6, 10 or 15A
A Accessories ccessoriescessoriesessoriesssoriessoriesoriesriesiesess GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord400: NEMA 5-15P to IEC 60320-1 C-13 line cord00: NEMA 5-15P to IEC 60320-1 C-13 line cord0: NEMA 5-15P to IEC 60320-1 C-13 line cord: NEMA 5-15P to IEC 60320-1 C-13 line cord
- _*IEC 60320-1 C14 inlet mates with C13 connector_
40
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **High Performance Power Line Filters for Medical Equipment** _(continued)_
## HT Series
**==> picture [493 x 588] intentionally omitted <==**
**----- Start of picture text -----**<br>
E Electrical lectrical S Schematics chematics HT3<br>3 & 6EHT<br>LINE LOAD Blue Blue<br>Green/Yellow<br>B<br>Brown Brown<br>10EHT i S F o ||<br>LINE LOAD A<br>C<br>D<br>Saee E<br><br>15EHT <br> <br>LINE LOAD <br>Cho<br>HT6<br>C Case ase S Styles tyles<br>HT1 (3, 6, 10A) E D B 1» )<br>E<br>B 2.00 ±0.01<br>50.80 ±0.25<br>A C<br><br>a C a = a <br>D <br>A<br><br> HT7 & HT7M<br> <br> <br>HT1 (15A)<br>B D<br>E D B<br>E<br>e s Bile<br>C A<br>2.00 ±0.01<br>50.80 ± 0.25 Sap C<br><br>A <br> <br> <br> <br> <br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
41
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**High Performance Power Line Filters for Medical Equipment** _(continued)_
## HT Series
## R Recommended ecommended P Panel anel C Cutout utout
**==> picture [140 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.575<br>0.235 40.01<br>R<br> 5.96<br>0.910<br> 23.1<br>0.157<br>Dia. 1.295<br> 3.98<br>32.89<br><br>**----- End of picture text -----**<br>
## C Case ase D Dimensions imensions
|Part No.|A<br>|B<br>|C<br>|D<br><br>__|E<br>|
|---|---|---|---|---|---|
|3EHT1,|****|****|****|****|****|
|6EHT1|__|__|__|__|__|
|3EHT3,|****|****|****|****|****|
|6EHT3|__|__|__|__|__|
|3EHT7 / 7M,|****|****|****|****|****|
|6EHT7/7M|__|__|__|__|__|
|10EHT1|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|10EHT3|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|15EHT1|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|15EHT6|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
__
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
**==> picture [493 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
3EHT 6EHT 10EHT 15EHT<br>db db db db<br>100 100 100 100<br>90 90 90 90<br>80 80 80 80<br>70 70 70 70<br>60 60 60 60<br>50 A NOEAI Conic 50 ANCO 50 VALCIE COTCol 50 CoE||COI<br>40 ET 40 YN 40 AN CIE 40 PCIE<br>30 Cn oe 30 CO SIE 30 PCI OIE 30 AACN<br>20 1 20 1 20 i 1, 20 WN<br>10 CIE COI Conic] 10 on ois 10 1 10 IE COI<br>0 4 oe 0 vy, mat 0 iy\ FH 0 Eee =<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|****||||****|****|****|****|****||||||****||||****|****|****|****|****|||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****||||||****|****|****|****||||****|****||||||****|****|****|****|||
||||||||||||||||||||||||||||
||||||||||||||||||||||||||||
||||||||||||||||||||||||||||
||||||||||||||||||||||||||||
42
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **High Performance Power Line Filter for Medical Applications**
## HZ Series
## UL Recognized CSA Certified VDE Approved
## S Specifications pecifications
## H HZ Z S Series eries
- Designed to provide good attenuation to RFI noise in the frequency range from 10kHz to 30MHz
Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: 2 A @250 VAC 50 Hz: 5 A Hipot rating (one minute): Line to Ground: 2250 VDC Line to Line: 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 to 30A Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
- Size and cost-effective
- Low leakage current
- New versions up to 30A
## O Ordering rdering I Information nformation
3 E HZ 1 ~~L~~ Input Input / / O Output utput Style Style 1 – .250 [6.3] spade terminals 6 – Threaded bolt
H HZ Z S Series eries L Leakage eakage c current urrent d designation esignation E – Low leakage _(<0.5 mA)_ C Current urrent R Rating ating 3, 4, 6, 10, 15, 20 or 30A
## C Case ase S Styles tyles
## 3EHZ1
## A Available vai . lable Part Numbers 3EHZ1 ~~Part Numbers~~
|3EHZ1<br>~~Part Numbers Numbers~~|~~Part Numbers Numbers~~|~~Part Numbers Numbers~~|4EHZ1||||~~"~~|~~"~~||~~@~~|~~@~~||||||B|B|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|6EHZ1<br>15EHZ1<br>30EHZ6|||10EHZ1<br>20EHZ1|||~~= =~~|||A<br>D<br>E<br>~~=~~|~~=~~||||L_|C<br>|—_4|||
## E Electrical lectrical S Schematic chematic
**==> picture [156 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>**----- End of picture text -----**<br>
__ __ __ __ __
43
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **High Performance Power Line Filter for Medical Applications** _(continued)_
## HZ Series
## C Case ase S Styles tyles _(continued)_
**==> picture [40 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
4EHZ1<br>**----- End of picture text -----**<br>
## 30EHZ6
**==> picture [483 x 334] intentionally omitted <==**
**----- Start of picture text -----**<br>
B B<br>[|°9| ;<br>C D<br>D — | | |, —__<br>_ _ C .— E<br>E<br>A<br>A<br><br> <br> <br> <br>6EHZ1<br><br> <br>a H e <br>\| e_ | a<br>B<br>Case Dimensions<br>|e + i Case Dimensions<br>C D A B C D E<br>E Part No. <br>| A -<br> <br> 3EHZ1<br> <br> <br> 4EHZ1<br>**----- End of picture text -----**<br>
|Case Dimensions<br>ase Dimensions<br>se Dimensions<br>e Dimensions<br>Dimensions<br>imensions<br>mensions<br>ensions<br>nsions<br>Part No.<br>3EHZ1<br>Case DimensionsDimensions|nsions<br>sions<br>ions<br>ons<br>ns<br>s<br>A<br><br>****<br>__<br>Case DimensionsDimensions|s<br>Case DimensionsDimensions|B<br><br>****<br>__|C<br><br>****<br>__|D<br><br>__<br>****<br>__<br>~~-~~|E<br><br>****<br>__|
|---|---|---|---|---|---|---|
|4EHZ1|****<br>__||****<br>__|****<br>__|****<br>__|****<br>__|
|6EHZ1|****<br>__||****<br>__|****<br>__|****<br>__|****<br>__|
|10EHZ1<br>15EHZ1|****||****|****|****|****|
|20EHZ1|__||__|__|__|__|
|30EHZ6|****<br>__||****<br>__|****<br>__|****<br>__|****<br>__|
## 10, 15 & 20EHZ1
**==> picture [206 x 122] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>\ le |<br>D<br>os C<br>E<br>A<br><br> <br> <br> <br>**----- End of picture text -----**<br>
44
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **High Performance Power Line Filter for Medical Applications** _(continued)_
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
## 6EHZ1
**==> picture [420 x 236] intentionally omitted <==**
**----- Start of picture text -----**<br>
3EHZ1 4EHZ1 6EHZ1<br>db db db<br>100 100 100<br>90 90 90<br>80 80 80<br>70 70 70<br>60 60 60<br>50 50 50<br>40 40 40<br>30 30 30<br>20 20 20<br>10 10 10<br>0 0.01 0.1 1 10 30 0 0.01 0.1 1 10 30 0 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz<br>10EHZ1 15EHZ1 20EHZ1<br>db db db<br>100 100 100<br>90 90 90<br>8070 OeICN ma 8070 COCCCIA co _] | 8070<br>60 CEN 60 COE AIaCoCri NI 60 mii<br>50 11 | 50 A | 50 molmeal<br>40 Fm, Sel 40 GY 2, 40 1<br>30 Cl SU 30 COATS 30 —_ ss”<br>20 CC 20 Pl 20 Ci PSS<br>10 CI 10 rr ICT 10 Ci Coes<br>0 0.01 0.1 1 10 30 Ci 0 0.01 0.1 1 10 30 COI | 0 0.01 0.1 1 10 30 Conco 7<br>Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## 30EHZ6
**==> picture [115 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db<br>100<br>90 COOL Con A<br>80 COil<br>605070 COCALY<br>403020100 AACCIEessP= (iATColAICoilSa<br> 0.01 0.1 1 10 30<br>Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|||||****|****|****|****||||||||****|****|****|****|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****||****|****|****|****|****|****|****||****|****||****|****|****|****|****|****|****|
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
45
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Single and 2-phase RFI Filters for Industrial Applications**
## IK Series
## I IK K S Series eries
- Excellent performance for applications with high interference levels
- Designed for single or two-phase applications
- Wide current range
- For small to medium sized industrial equipment, power converters and variable speed motors
- Touch safe terminals on the 6 to 60A product provide easy connections and prevent inadvertent contact for safety in the most demanding applications
## O Ordering rdering I Information nformation
1 IK 1 C L Suffix Suffix C – Ground Choke _(1IK1C only)_ I Input nput / Output / Output S Style tyle 1 – .250 [6.3] spade terminals 10 – DIN type terminal block
- _16 & 35IK: DIN input / Wire leads output 50 & 80IK: DIN input / DIN output_
## S Specifications pecifications
Maximum leakage current each Line to Ground: @120 VAC 60 Hz:
|@120 VAC 60 Hz:|||
|---|---|---|
|16, 35 & 50IK:|1IK & 6IK:<br>16, 35 & 50IK:|0.6 mA<br>1.7 mA|
||80IK:|5.2 mA|
|@289 VAC 50 Hz:<br>@277 VAC 50 Hz:|1IK:<br>6IK:|1.2 mA<br>1.15 mA|
|16, 35 & 50IK:|16, 35 & 50IK:|3.2 mA|
||80IK:|9.9 mA|
|Hipot rating (one minute):|||
|Line to Ground:<br>Line to Line:||2250 VDC<br>1450 VDC|
|Rated Voltage (max):|1IK|6 to 80IK|
|Line to Ground:<br>Line to Line:|289 VAC<br>277 VAC|500 VAC<br>480 VAC|
|Operating Frequency:||50/60 Hz|
|Rated Current:||1 to 80A|
Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
I IK K S Series eries
## E Electrical lectrical S Schematic chematic
C Current urrent R Rating ating 1, 6, 16, 35, 50 & 80A
**==> picture [492 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>Available Part Number 2<br>1<br>1IK1C 6IK1 2<br>Available 16IK10 Part Number 35IK10 — O C :<br>50IK10 80IK10<br>| = ; =<br> <br> <br>**----- End of picture text -----**<br>
46
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Single and 2-phase RFI Filters for Industrial Applications**
## IK Series
**==> picture [477 x 579] intentionally omitted <==**
**----- Start of picture text -----**<br>
Case Styles<br>1IK1C 16 & 35IK10<br>C<br>B<br>D iLeo C 7<br>E A<br>A F<br> Black<br> — p e<br> B 38.01.49 Brown<br>i [a.] n E<br>6IK1 D<br>-P—<br><br> <br> <br> <br>B<br>50 & 80IK10<br>a<br>D<br>C<br>E<br>C<br>=a" A )<br><br> <br> A<br> <br>-———_ F<br>B 2.36<br>T e 60.0 t<br>E<br>D<br>|;<br><br> <br> <br> <br>**----- End of picture text -----**<br>
47
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help**
**corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Single and 2-phase RFI Filters for Industrial Applications**
## IK Series
## C Case ase D Dimensions imensions
|Part No.|Part No.|A<br>|B<br>|C<br>|D<br><br>__|E<br>|F<br><br>__|
|---|---|---|---|---|---|---|---|
|1IK1C||****|****|****|****|****|__|
|||__|__|__|__|__||
|6IK1||****|****|****|****|****|__|
|||__|__|__|__|__||
|16IK10||****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|35IK10||****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|50IK10||****|****|****|****|****|****|
|80IK10||__|__|__|__|__|__|
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [322 x 227] intentionally omitted <==**
**----- Start of picture text -----**<br>
1IK1C 6IK1<br>db db<br>100 100<br>90 90<br>80 80<br>40605070 ||1Ho) mmji || 40605070 eeOllinn<br>30 30<br>20 20<br>10 10<br>0 0.01 0.1 1 10 30 callaa, iSag| 0 0.1 1 10 30 EHeeEHHHIP<br>Frequency in MHz Frequency in MHz E<br>16 & 35IK10 50 & 80IK10<br>db db<br>10090 CO cy 10090<br>8070 Con 7 fil 8070 CC<br>60 CO Ae" | 60 rllLATIN<br>50 CO Zeno 50 wos XN<br>40 Ce 40 A I<br>30 Co | a. 30 af i une<br>20 600iot |i ||||| 20 IeA<br>10 CO Cl 10 er Co<br>0 0<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) ~~D~~ ifferential Mode / Symmetrical (L-L)
48
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **General Purpose RFI Power Line Filters – Ideal for High Impedance Load**
## K Series ®
UL Recognized CSA Certified VDE Approved**
**==> picture [182 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
VK6 VK7 / EK7<br><D<br>VK1 / EK1<br>VK3 / EK3<br>**----- End of picture text -----**<br>
## K Seriesriesiesess K Seriesriesiesess Series eriesriesiesess
## K Seriesriesiesess
- Suitable for high impedance loads
- Well suited to applications where pulsed, continuous and/or intermittent RFI interference is present
- EK models meet the very low leakage current requirements for VDE portable equipment and non-patient care medical equipment
- Available with ground line inductor (choke)
## O Ordering rdering I Information nformation
## 10 E K 7 M
L Suffix Suffix M – Metric inserts _(style 7 only)_ Omit for standard or none C – Ground choke _(30, 40VK6 only)_ I Input nput / Output / Output S Style tyle 1 – .250 [6.3] spade terminals 3 – Wire leads 6 – Threaded bolt 7 – IEC inlet* _(line side)_ .250 [6.3] spade terminals _(load side)_ K K S Series eries
> L Leakage eakage c current urrent d designation esignation E – Low leakage _(<0.5 mA)_ V – Standard C Current urrent R Rating ating 1, 2, 3, 5, 10, 20, 30, 40 or 60A
## S Specifications pecifications
Maximum leakage current each Line to Ground:
|@ 120 VAC 60 Hz:<br>@250 VAC 50 Hz:|VK Models<br>.5 mA<br>1.0 mA|EK Models<br>.21 mA<br>.36 mA|
|---|---|---|
|Hipot rating (one minute):<br>Line to Ground:<br>Line to Line:||2250 VDC<br>1450 VDC|
|Rated Voltage (max):||250 VAC|
|Operating Frequency:||50/60 Hz|
|Rated Current:||1 to 60A*|
|Operating Ambient Temperature Range|||
|(at rated current Ir):||-10°C to +40°C|
|In an ambient temperature (Ta) higher than +40°C<br>the maximum operating current (Io) is calculated as<br>follows: Io = Ir (85-Ta)/45<br>~~oO~~|||
## A Available vailable P Part art N Numbers umbers
|1VK1<br>1VK3<br>2VK1<br>2VK3<br>3VK1<br>3VK3<br>3VK7<br>3VK7M<br>5VK1<br>5VK3<br>5VK7<br>5VK7M<br>10VK1<br>10VK3|10VK6<br>10VK7<br>10VK7M<br>20VK1<br>20VK6<br>20VK7*<br>30VK6<br>30VK6C<br>40VK6<br>40VK6C<br>60VK6<br>1EK1<br>1EK3<br>2EK1|2EK3<br>3EK1<br>3EK3<br>3EK7<br>3EK7M<br>5EK1<br>5EK3<br>5EK7<br>5EK7M<br>10EK1<br>10EK3<br>10EK7<br>10EK7M<br>20EK1|
|---|---|---|
- _*1-15A: IEC 60320-1 C14 inlet mates with C13 connector 20VK7: C20 inlet mates with C19 connector_
- _**20VK7, 20A model tested by Underwriters Laboratories to US and Canadian requirements and is VDE approved at 16A, 250VAC_
49
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **General Purpose RFI Power Line Filters** _(continued)_
## K Series
## E Electrical lectrical S Schematics chematics
**==> picture [215 x 199] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>30 & 40VK6C (Inductor in Ground Line)<br>LINE LOAD<br>—<br>= [TCHR]<br>60VK6<br>LINE LOAD<br>**----- End of picture text -----**<br>
Accessories Accessories G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord |
**==> picture [226 x 355] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles<br>K1 (1, 2, 3, 6, 10A)<br>i li<br>E D B<br>f is 4 | A LL C<br><br> <br> <br> <br>— —J Lo<br>K1 (20A)<br>iall o F<br>E D B<br>] TL<br>A _ . C _<br>= | |<br><br> <br> <br> <br>**----- End of picture text -----**<br>
**==> picture [17 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
K3<br>**----- End of picture text -----**<br>
**==> picture [164 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
vy4 20VK7<br>20VK6<br>VK1/EK1<br>**----- End of picture text -----**<br>
**==> picture [241 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
Blue Blue<br>Green/Yellow<br>E D B [> (©)<br>| Brown a Brown ©<br>__7 A ] OL.. C<br><br> <br> <br>**----- End of picture text -----**<br>
50
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **General Purpose RFI Power Line Filters** _(continued)_
## K Series
**==> picture [119 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles (continued)<br>**----- End of picture text -----**<br>
**==> picture [487 x 570] intentionally omitted <==**
**----- Start of picture text -----**<br>
10VK6 60VK6<br>an<br>E D B<br>E D B<br>a nf | [ E m | oom | |<br>2.00<br>50.8<br>A C C<br>= ne A<br> <br> <br> <br>20VK6 K7 & K7M (3, 5, 10A)<br>Tapped insert<br>D B<br>E D B<br>Y aa =< O Ie |S 7<br>an f | | [ E m A — E 4<br>C<br>A 4) C f<br>(|<br> <br> <br> <br> <br>30VK6/6C & 40VK6/6C <br>Terminal on 30VK6C and 40VK6C only<br>20VK7<br>v i ll e e Bi : a E A .<br>E D B<br>D B<br>n h i<br>ee C 2. 67.31 ± .40 65 ± .016<br>2.00<br>50.8 .669 ± .010<br>16.99 ± .25<br>A C > a 13.00 ± .25 .512 ± .010<br><br> <br> <br> <br> <br> <br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
51
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **General Purpose RFI Power Line Filters** _(continued)_
## K Series
## C Case ase D Dimensions imensions
## R Recommended ecommended P Panel anel C Cutouts utouts
## K7 & K7M Cutout (3, 5, 10A)
**==> picture [493 x 566] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|A|B|C|D|E|
|Part No.||.235|
||||||R|.157|
|5.96|Dia.|
|1VK1, 1EK1,||||||3.98|
|2VK1, 2EK1||||||
|.910|
|1VK3, 1EK3,||||||23.1|
|2VK3, 2EK3||||||
|3VK1, 3EK1,||||||1.295|
|5VK1, 5EK1||||||32.89|
|1.575|
|3VK3, 3EK3,||||||
|40.01|
|5VK5, 5EK3||||||
|3VK7/7M,||||||[]|20VK7 Cutout|
|5VK7/7M,3EK7/7M|||||||||||[]|[]|R|.062|1.60|.157|4.0|[Dia. ]|
|5EK7/7M||||||[]|
|10VK1,||||||1.46|
|10EK1||||||37.1|
|10VK3,||||||
|10EK3||||||1.145|
||||||29.1|
|10VK6|
||||||D|
|10VK7/7M,||||||[]||
|10EK7/7M||||||[]|
|20VK1,||||||
|20EK1||||||P|Performance|erformance D|Data|ata|
||||||Typical Insertion Loss|
|20VK6|
||||||Measured in closed 50 Ohm system|
|20VK7|||||||||||[]|[]|1 & 3EK100db|2 & 10EK100db|
|30VK6,||||||9080|9080|
|30VK6C||||||70|70|
|60|60|
|40VK6,||||||50|50|
|Bn|40|ih|SN|40|Ht|i|
|40VK6C|
||||||30|30|
|60VK6|es||||||Ro|2010|A||2010|eo|Coe|
||||||0|0.1 1 10 30|ECE|0|0.1 1 10 30|EPH|EH|
|Frequency in MHz|Frequency in MHz|
||||5EK|20EK|
||||db|db|
|10090|||10090|Coo|o_o|
|80|80|
|70|FHS)|70|ESHA|
|60|Co|my,|60|Cel|||
|50|||A|50|mee|Lu|=|
|4030|a)Ogeea|4030|CCAee|ee|
|20|20|
|10|10|
|0|0.1 1 10 30|L CO|Co|0|0.1 1 10 30|CC ConCi4|
|Frequency in MHz|Frequency in MHz|
**----- End of picture text -----**<br>
52
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **General Purpose RFI Power Line Filters** _(continued)_
## K Series
**==> picture [493 x 382] intentionally omitted <==**
**----- Start of picture text -----**<br>
Performance Data (continued)<br>Typical Insertion Loss<br>Measured in closed 50 Ohm system<br>1VK 2VK 3VK 5VK<br>db db db db<br>100 100 100 100<br>90 90 90 90<br>80 80 80 80<br>70 70 70 70<br>60 60 60 60<br>50 50 50 50<br>40 40 40 40<br>30 30 30 30<br>20 20 20 20<br>100 Bee 100 100 100 AH HHH<br>0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>10VK 20VK 30VK & 30VK6C<br>db db db Be<br>100 100 100<br>90 90 90<br>80 80 80<br>70 70 70<br>60 60 60<br>50 50 50<br>40 40 40<br>30 30 30<br>20 20 20<br>10 10 10<br>0 0 0<br>0.1 1 10 30 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz<br>40VK & 40VK6C 60VK<br>db db<br>100 100<br>90 90<br>80 80<br>70 70 : Common Mode / Asymmetrical (L-G)<br>60 60 Differential Mode / Symmetrical (L-L)<br>50 50<br>40 40<br>30 30<br>20 20<br>10 10<br>0 0<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground)
||****||****|****|****|****||
|---|---|---|---|---|---|---|---|
||****|****|****|****|****|****|****|
||****|||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|****||||||||
|||||||||
|||||||||
|||||||||
Differential Mode / Symmetrical (Line to Line)
||****||****|****|****|****||
|---|---|---|---|---|---|---|---|
||****|****|****|****|****|****|****|
|****||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|****||||||||
|||||||||
|||||||||
|||||||||
53
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help**
**corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Multi-purpose Medical Filter for Power Line Noise Protection**
## MV Series
UL Recognized CSA Certified VDE Approved
## MV S Seriesriesiesess MV V S Seriesriesiesess Series eriesriesiesess
## MV S Seriesriesiesess
- Multi-purpose medical filter
- Improved Line to Ground performance
- A good solution to emission or immunity problems
- Meets leakage current requirements of UL2601 for health care equipment
## S Specifications pecifications
|S<br>pecifications<br>ecifications<br>cifications<br>ifications<br>fications<br>cations<br>ations<br>tions<br>ions<br>ons<br>ns<br>s<br>Specifications||
|---|---|
|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:|
|@ 120 VAC 60 Hz:<br>@250 VAC 50 Hz:<br>Hipot rating (one minute):<br>Line to Ground:|.07 mA<br>.13 mA<br>2250 VDC|
|Line to Line:|1450 VDC|
|Rated Voltage (max):|250 VAC|
|Operating Frequency:|50/60 Hz|
|Rated Current:|3 to 20A|
|Operating Ambient Temperature Range||
|(at rated current Ir):|-10°C to +40°C|
|In an ambient temperature (Ta) higher than +40°C||
|the maximum operating current (Io) is calculated as|the maximum operating current (Io) is calculated as<br>follows: Io = Ir (85-Ta)/45|
## O Ordering rdering I Information nformation
6 MV 1 LL I Input nput / / O Output utput S Style tyle 1 – .250 [6.3] spade terminals MV Series MV Series C Current urrent R Rating ating 3, 6, 10 or 20A
## E Electrical lectrical S Schematic chematic
LINE LOAD
## A Available vailable P Part art N Numbers umbers
|3MV1|6MV1|
|---|---|
|10MV1|20MV1|
54
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Multi-purpose Medical Filter for Power Line Noise Protection** _(continued)_
## MV Series
## C Case ase S Styles tyles MV1 (3, 6, 10A)
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [493 x 403] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|3MV|6MV|
|db|db|
|iE|+|i|100|100|
|B|90|90|
|80|80|
|70|70|
|60|60|
|[3|50|50|Ere|rt|
|D|4030|4030|
|C|E|20|20|
|10|10|
|A|0|0.1 1 10 30|0|0.1 1 10 30|
|Frequency in MHz|Frequency in MHz|
|10MV|20MV|
||db|db|
|||||||100|100|
|||||||90|90|
|||||80|80|
|70|70|
|60|60|
|20MV1|4050|4050|
|30|30|
|20|20|
|10|10|
|0|0.1 1 10 30|0|0.1 1 10 30|ae|
|:|Frequency in MHz|Frequency in MHz|
|-|Common Mode / Asymmetrical (L-G)|
|E|D|B|f|
|Differential Mode / Symmetrical (L-L)|
|tI|TL|
|Minimum Insertion Loss|
|Measured in closed 50 Ohm system|
|2.00|
|50.8|Common Mode / Asymmetrical (Line to Ground)|
|ia_}|A|a|C|Sy|are|
|||
||
||||||||||||||||
|||||||
||||||||||||||
||||||||||
|Dimensions|Case Dimensionsase Dimensionsse Dimensionse Dimensions Dimensionsimensionsmensionsensionsnsionssionsionsonsnss||||||||||
|Case|
|A|B|C|D|E||||||||||
**----- End of picture text -----**<br>
## ~~Dimensions~~ Case Dimensionsase Dimensionsse Dimensionse Dimensions Dimensionsimensionsmensionsensionsnsionssionsionsonsnss ~~Case~~
**==> picture [488 x 131] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|A|B|C|D|E||||||||||
|Part No.||
||||||
||||||Differential Mode / Symmetrical (Line to Line)|
|3MV1|
||||||||
|||||||||||||||
|6MV1|
||||||
||||||||||
||||||
|10MV1||||||||||
||||||
|||||||||||||||
|20MV1|
||||||
||||||||||
**----- End of picture text -----**<br>
55
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **High Performance RFI Filters for Switching Power Supplies**
## N Series
UL Recognized CSA Certified VDE Approved
**==> picture [139 x 45] intentionally omitted <==**
**----- Start of picture text -----**<br>
6VN1<br>10VN1<br>**----- End of picture text -----**<br>
## N N S Series eries
- Superior attenuation for most digital electronic equipment over the frequency range of 10kHz to 30MHz
- Provides excellent common mode and differential mode performance
- Cost-effective solution to very noisy equipment that must meet conducted emission limits
## O Ordering rdering I Information nformation
## S Specifications pecifications
Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: 1.2 mA @250 VAC 50 Hz: 2.0 mA Hipot rating (one minute): Line to Ground: 2250 VDC Line to Line: 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 6 to 10A Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
## 10 V N 1
- I Input nput / Output / Output S Style tyle 1 – .250 [6.3] spade terminals
- N N S Series eries L Leakage eakage c current urrent d designation esignation V – Standard
- C Current urrent R Rating ating 6 or 10A
## Electrical Schematics Electrical Schematics
## 3VN
**==> picture [184 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>**----- End of picture text -----**<br>
## 10VN
## A Available vailable P Part art N Numbers umbers
LINE LOAD
6VN1 10VN1
56
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **High Performance RFI Filters for Switching Power Supplies** _(continued)_
## N Series
## C Case ase S Styles tyles
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [241 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>— =<br>| a= ‘|<br>r D e ee C<br>E<br>A<br><br> <br> <br> <br>**----- End of picture text -----**<br>
**==> picture [240 x 143] intentionally omitted <==**
**----- Start of picture text -----**<br>
6VN 10VN<br>db db<br>100 100<br>90 90<br>80 80<br>Cn<br>70 i a 70 Hl gt i<br>60 60<br>50 mali 50 tN” 00<br>40 40<br>30 2dL——™ 30 ON)(A<br>2010 |ae| ee 2010<br>0 0.01 0.1 1 10 30 0NN| 0 0.01 0.1 1 10 30 D, eae<br>Frequency in MHz Frequency in MHz<br>Common Mode / Asymmetrical (L-G)<br>Differential Mode / Symmetrical (L-L)<br>**----- End of picture text -----**<br>
## C Case ase D Dimensions imensions
|Part No.|Part No.|A<br>|B<br>|C<br>|D<br><br>__|E<br>|
|---|---|---|---|---|---|---|
|6VN1||****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|10VN1||****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
|****||||****|****|****|****|||
|---|---|---|---|---|---|---|---|---|---|
|****|****||****|****|****|****|****|****|****|
|||||||||||
|||||||||||
Differential Mode / Symmetrical (Line to Line)
|****||||****|****|****|****|||
|---|---|---|---|---|---|---|---|---|---|
|****|****||****|****|****|****|****|****|****|
|||||||||||
|||||||||||
57
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Highest Performance RFI Filters for Switching Power Supplies**
## Q Series
UL Recognized CSA Certified VDE Approved
**==> picture [113 x 82] intentionally omitted <==**
**----- Start of picture text -----**<br>
Q8<br>| ~<br>Q1<br>Q3<br>**----- End of picture text -----**<br>
## Q @ S Series eries
- Specifically developed for switching power supplies
- High attenuation for common and differential mode interference
- Effective from 10kHz to 30MHz
- Optimized for attenuation and size
- 3 or 6A versions available with IEC inlet
## O Ordering rdering I Information nformation 6 E Q 8 M
## L Suffix Suffix
M – Metric inserts _(style 8 only)_ Omit for standard or none
> I Input nput / / O Output utput S Style tyle 1 – .250 [6.3] spade terminals 3 – Wire leads
8 – IEC inlet* _(line side)_ Wire leads _(load side)_
> Q Q S Series eries
> L Leakage eakage c current urrent d designation esignation E – Low leakage _(<0.5 mA)_ V – Standard
> C Current urrent R Rating ating 3, 6 or 20A
## S Specifications pecifications
Maximum leakage current each Line to Ground:
|3<br>&<br>2<br>0<br>A<br>3 &20A|VQ Models|EQ Models|
|---|---|---|
|@120 VAC 60 Hz:|.73 mA|.22 mA|
|@250 VAC 50 Hz:|1.27 mA|.38 mA|
|6<br>A<br>@120 VAC 60 Hz:<br>@250 VAC 50 Hz:<br>~~6A~~|—<br>—|.29 mA<br>.51 mA|
|Hipot rating (one minute):|||
|Line to Ground:||2250 VDC|
|Line to Line:||1450 VDC|
|Rated Voltage (max):||250 VAC|
|Operating Frequency:||50/60 Hz|
|Rated Current:||3 to 20A|
|Operating Ambient Temperature Range<br>(at rated current Ir):<br>-10°C to +40°C|||
|In an ambient temperature (Ta) higher than +40°C<br>the maximum operating current (Io) is calculated as<br>follows: Io = Ir (85-Ta)/45|||
## A Available vailable P Part art N Numbers umbers
|3EQ1<br>3EQ3<br>3EQ8<br>3EQ8M<br>6EQ1<br>6EQ3<br>6EQ8|6EQ8M<br>20EQ1<br>3VQ1<br>3VQ3<br>3VQ8<br>3VQ8M<br>20VQ1|
|---|---|
## A Accessories ccessories
> G GAZOG A400: NEMA 5-15P to IEC 60320-1 C-13 line cord
_*IEC 60320-1 C14 inlet mates with C13 connector_
58
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Highest Performance RFI Filters for Switching Power Supplies** _(continued)_
## Q Series
## E Electrical lectrical S Schematics chematics
**==> picture [218 x 97] intentionally omitted <==**
**----- Start of picture text -----**<br>
3A<br>LINE LOAD<br>6, 20A<br>LINE LOAD<br>**----- End of picture text -----**<br>
**==> picture [204 x 170] intentionally omitted <==**
**----- Start of picture text -----**<br>
Q8, Q8M (3A)<br>Tapped insert<br>Brown<br>Grn/Yel<br>Blue D B<br>= A ) E<br>C<br><br> <br> <br> <br> <br>**----- End of picture text -----**<br>
## Q8, Q8M (6A)
## C Case ase S Styles tyles
**==> picture [206 x 204] intentionally omitted <==**
**----- Start of picture text -----**<br>
Q1<br>3, 20A Models<br>|<br>alll IF f<br>B<br>D C<br>E<br>A 6A Models<br>B<br>2 3),<br>C<br><br> ee <br> <br> <br>Q3<br>**----- End of picture text -----**<br>
**==> picture [241 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
Tapped insert<br>- _ —<br>Grn/Yel C<br>.<br>Blue Brown 016.0.63 Ref<br>.313 Ref<br>7.95<br>B E D<br>A<br><br> <br> <br> <br> <br>**----- End of picture text -----**<br>
## Caseasesee Dimensions ~~Case~~
**==> picture [493 x 222] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
||Caseasesee Dimensions|
|||||||Dimensions|
|||||||A|B|C|D|E|
|||||Part No.||
||||||
|Q3|
||||||
|3A Models|3VQ1, 3EQ1|
||||||
|Blue|Blue|
|Grn/Yel|BlueGrn/Yel|B|3VQ3, 3EQ3||||||
|Brown|Brown||||||
|Brown|
|3VQ8/8M,||||||[]|
|A|C|3EQ8/8M||||||[]|
|D|
|a|E|6A Models|6EQ1||||||
||||||
|Blue|B||||||
|Grn/Yel|Brown|6EQ3||||||
|a)|,|BC|
||||||
|C|e|ff|||6EQ8/8M|
|||||||
|||||20EQ1,||||||[]|
|||
|20VQ1||||||[]|
**----- End of picture text -----**<br>
__
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
59
For email, phone or live chat, please go to **te.com/help**
**corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Highest Performance RFI Filters for Switching Power Supplies** _(continued)_
## Q Series
## R Recommended ecommended P Panel anel C Cutout utout
**==> picture [94 x 92] intentionally omitted <==**
**----- Start of picture text -----**<br>
.235 .157<br>5.96 R 3.98 Dia. (2)<br>.910<br>23.11<br>1.295<br>32.89<br>1.575<br>40.01<br><br>**----- End of picture text -----**<br>
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [493 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
3VQ 3EQ 6EQ 20VQ<br>db db db db<br>100 100 100 100<br>90 90 90 90<br>8070 COZ 8070 COI 8070 ATTAIN 8070<br>60 OL ——— 60 PE 60 ‘AGG 60 a .<br>50 CA oI 50 Aston 50 OO Caos 50 iC<br>40 >”CO6Co |oi 40 I Co 40 Hee| | i 2 40 CoCon<br>30 30 30 30<br>20 ColCIE CoHU 20 yyCA CnCIae 20 2 nel 20 SieCOI COI |<br>10 10 10 10<br>0 FEET tH 0 EET eer 0 EE 0 RHI<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## 20EQ
**==> picture [114 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
db<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>0.01 0.1 1 10 30<br>Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|****|||****|****|****|****|||||****|||****|****|****|****||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****|****||****|****|****|****|****|****|****|****|****|****|
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
60
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Two-stage General Purpose RFI Power Line Filter**
## R Series
## UL Recognized WE CSA Certified VDE Approved
**==> picture [179 x 114] intentionally omitted <==**
**----- Start of picture text -----**<br>
VR7/7M<br>VR3/ER3 —- —,<br>aie, “ta<br>10VR6<br>VR1/ER1<br>**----- End of picture text -----**<br>
## R Seriesriesiesess R Seriesriesiesess Series eriesriesiesess
## R Seriesriesiesess
- Dual T section RFI filter provides premium performance
- Well suited for low impedance loads where noisy RFI environments are present
- Controls pulsed, continuous and/or intermittent interference
- ER models offer low leakage current without deterioration of insertion loss
## O Ordering rdering I Information nformation
10E R 7 M
- L Suffix Suffix M – Metric inserts _(style 8 only)_ Omit for standard or none C – Ground choke _(select models)_
- I Input nput / / O Output utput S Style tyle 1 – .250 [6.3] spade terminals 3 – Wire leads
- 6 – Threaded bolt
- 7 – IEC inlet* _(line side)_
- .250 [6.3] spade terminals
_(load side)_
- R R S Series eries
> L Leakage eakage c current urrent d designation esignation E – Low leakage _(<0.5 mA)_ V – Standard
C Current urrent R Rating ating 1, 2, 3, 5, 10 or 20A
- _*IEC 60320-1 C14 inlet mates with C13 connector_
## S Specifications pecifications
Maximum leakage current each Line to Ground:
||VR Models|ER Models|
|---|---|---|
|@120 VAC 60 Hz:<br>@250 VAC 50 Hz:|.4 mA<br>.7 mA|.21 mA<br>.36 mA|
|Hipot rating (one minute):<br>Line to Ground:<br>Line to Line:||2250 VDC<br>1450 VDC|
|Rated Voltage (max):||250 VAC|
|Operating Frequency:||50/60 Hz|
|Rated Current:||1 to 20A|
Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
## A Available vailable P Part art N Numbers umbers
|1VR1<br>1VR3<br>2VR1<br>2VR3<br>3VR1<br>3VR3<br>3VR7<br>3VR7M<br>5VR1<br>5VR3<br>5VR7<br>5VR7M<br>10VR1<br>10VR3<br>10VR6<br>10VR7<br>10VR7M<br>20VR1<br>20VR6|1ER1<br>1ER3<br>2ER1<br>2ER3<br>3ER1<br>3ER3<br>3ER7<br>3ER7M<br>5ER1<br>5ER3<br>5ER7<br>5ER7M<br>10ER1<br>10ER3<br>10ER7<br>10ER7M<br>20ER1|
|---|---|
61
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Two-stage General Purpose RFI Power Line Filter** _(continued)_
## R Series
## E Electrical lectrical S Schematic chematic
**==> picture [228 x 348] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>a<br>C Case ase S Styles tyles<br>R1 (1, 2, 3, 5, 10A)(1, 2, 3, 5, 10A)<br>B<br>4] | F- S a<br>D<br>E<br>A C<br><br> <br> <br> <br>**----- End of picture text -----**<br>
R1 (1, 2, 3, 5, 10A)(1, 2, 3, 5, 10A)
**==> picture [235 x 184] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles (continued)<br>R3<br>Blue Blue<br>B<br>Brown Brown<br>— — f<br>—<br>| "<br>A Green/<br>D Yellow<br>E C<br>=! " T<br><br> <br> <br>**----- End of picture text -----**<br>
## 10VR6
**==> picture [237 x 110] intentionally omitted <==**
**----- Start of picture text -----**<br>
oft | Ruin | B<br>D<br>C<br>E<br>A<br><br> <br> <br>**----- End of picture text -----**<br>
**==> picture [48 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
R1 (20A)<br>**----- End of picture text -----**<br>
**==> picture [208 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
E D B me<br>| FL<br>2.00<br>50.8<br>A C<br><br> <br> <br> <br>**----- End of picture text -----**<br>
**==> picture [230 x 168] intentionally omitted <==**
**----- Start of picture text -----**<br>
20VR6<br>—— — F e<br>th e<br>E D B<br>ile ©<br>| | t l Hus<br>2.00<br>50.8<br>A C<br><br> <br> <br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
62
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Two-stage General Purpose RFI Power Line Filter** _(continued)_
## R Series
> C Case ase S Styles tyles _(continued)_ R7 & R7M Tapped insert ~~wail~~ D B f ~~e)~~ A E ~~ae~~ C G| ~~]~~ = __ __ __ __
## R Recommended ecommended P Panel anel C Cutout utout
**==> picture [78 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
.235 .157<br>5.96 R 3.98 Dia. (2)<br>.910<br>23.11<br>1.295<br>32.89<br>1.575<br>40.01<br>**----- End of picture text -----**<br>
**==> picture [68 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
<br>**----- End of picture text -----**<br>
**==> picture [241 x 353] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|C|Case|ase D|Dimensions|imensions|
|A|B|C|D|E|
|Part No.||
||||||
|1VR1, 1ER1,||||||
|2VR1, 2ER1||||||
|1VR3, 1ER1,||||||
|2VR3, 2ER3||||||
|OS|
|3VR1, 3ER1,||||||
|5VR1, 5ER1||||||
|3VR3, 3ER3,||||||
|5VR3|a|, 5ER3||||||
|3VR7/7M,||||||[]|
|3ER7/7M||||||[]|
|5VR7/7M,||||||[]|
|5ER7/7M||||||[]|
|10VR1,||||||
|10ER1||||||
|10VR3,||||||
|10ER3||||||
|OO|
||||||
|10VR6|
||||||
|10VR7/7M,||||||[]|
|10ER7/7M||||||[]|
|20VR1,||||||
|20ER1||||||
||||||
|20VR6|
||||||
**----- End of picture text -----**<br>
__
## A Accessories ccessories
> G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord
63
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Two-stage General Purpose RFI Power Line Filter** _(continued)_
## R Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
## 1ER
## 3ER
## 5ER
## 2ER, 10ER & 20ER
**==> picture [493 x 208] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db db db<br>10090 a 10090 | || 10090 | 10090 |<br>80 aCa 80 a) || 80 LT 7S 80 |ee<br>70 70 70 70<br>60 tl —— a 60 may. — 60 ee) 60 en) pee<br>50 0 50 | TAA TT 50 ae) | 50 |_| | Ue =—<br>40 a 40 LAAVAR ALUMAnti a || 40 aey2)2A|| 40 LT| Aa AA<br>30 v i 30 CAL 30 | PAA TTT 30 LAME Tr<br>2010 aa 2010 || || 2010 LALAA |Ti 2010 AACZ|<br>0 a 0 | | 0 Ee 0 ee|<br>0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>1VR 2VR 3VR 5VR<br>db db db db<br>1009080 1009080 a | 1009080 -_ 1009080<br>70 70 70 70<br>60 60 60 60<br>50 50 oa 50 ; 50<br>40 40 40 40<br>30 30 30 30<br>20 20 VA 20 EE 20 |<br>100 100 || 100 eeee 100 ee|<br>0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## 10VR 20VR
**==> picture [240 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db<br>100 100<br>90 mani | 90<br>80 mani ———~ 80<br>70 eer | LN 70 ———<br>60 60<br>50 50<br>40 40<br>30 30<br>20 20<br>i<br>100 a 100 ee |<br>0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|****||****|****|****|****|||****||****|****|****|****||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****||****|****|****|****|****|****|****|
|****|||||||****||||||||
||||||||||||||||
||||||||||||||||
|****|||||||****||||||||
||||||||||||||||
||||||||||||||||
64
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **High Performance Compact Power Line Filter**
## RK Series
UL Recognized CSA Certified VDE Approved
## R RK K S Series eries
- Compact
- Single stage
- Chassis mount
- Significant differential mode performance
- Suitable for industrial machinery
- Low input leakage current makes it suitable for portable equipment
## O Ordering rdering I Information nformation
10 E RK 1 L Input Input / / O Output utput Style Style 1 – .250 [6.3] spade terminals R RK K S Series eries L Leakage eakage c current urrent d designation esignation E – Low leakage _(<0.5 mA)_ Current Rating Current Rating 3, 6, 10, 15 or 20A
## S Specifications pecifications
Maximum leakage current each Line to Ground:
|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:|
|---|---|
|@ 120 VAC 60 Hz:<br>@250 VAC 50 Hz:|0.16 mA<br>0.26 mA|
|Hipot rating (one minute):<br>Line to Ground:|2250 VDC|
|Line to Line:|1450 VDC|
|Rated Voltage (max):|250 VAC|
|Operating Frequency:|50/60 Hz|
|Rated Current:|3 to 20A|
|Operating Ambient Temperature Range||
|(at rated current Ir):|-10°C to +40°C|
|In an ambient temperature (Ta) higher than +40°C<br>the maximum operating current (Io) is calculated as<br>follows: Io = Ir (85-Ta)/45||
## E Electrical lectrical S Schematic chematic
LINE LOAD
## A Available vailable P Part art N Numbers umbers
|3ERK1|6ERK1|
|---|---|
|10ERK1|15ERK1|
|20ERK1||
65
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **High Performance Compact Power Line Filter** _(continued)_
## RK Series
## C Case ase S Styles tyles
## R RK K1 (3 & 6A)
**==> picture [151 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>E<br>D<br>ian C<br>| “Wl<br>B<br>**----- End of picture text -----**<br>
|C<br>a<br>s<br>e<br>D<br>i<br>m<br>e<br>n<br>s<br>i<br>o<br>n<br>s<br>Case Dimensions|||||
|---|---|---|---|---|
|Part No.<br>A<br>|B<br>|C<br>|D<br><br>__<br>~~a~~|E<br>|
|3ERK1<br>****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|6ERK1<br>****|****|****|****|****|
|__<br>~~BO~~|__<br>~~BO~~|__<br>~~BO~~|__<br>~~BO~~|__<br>~~BO~~|
|10ERK1, 15ERK1,<br>****|****|****|****|****|
|20ERK1<br>__|__|__|__|__|
## R RI K1 (10, 15 & 20A)
- A E
- rT C D :
- °@ = _k || Tl B
- _ 4 | \/
- __ __ __ __ __
66
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **High Performance Compact Power Line Filter** _(continued)_
## RK Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [493 x 220] intentionally omitted <==**
**----- Start of picture text -----**<br>
3RK 6RK 10RK 15RK<br>db db db db<br>100 100 100 100<br>90 90 90 90<br>80 80 80 80<br>70 HEC H 70 ass H 70 CHIE CHS 70 i m ai<br>60 60 60 60<br>50 50 50 50<br>40 40 40 40<br>30 30 30 30<br>20 20 20 20<br>10 10 10 10<br>0 0 0 0<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>20RK<br>db<br>100<br>90<br>80<br>70<br>60 Common Mode / Asymmetrical (L-G)<br>50 Differential Mode / Symmetrical (L-L)<br>40<br>30<br>20<br>10<br>0<br>0.01 0.1 1 10 30<br>Frequency in MHz<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|****||||****|****|****|****|||||****||||****|****|****|****||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|||****|****|****|****|****|****|****||****|****|||****|****|****|****|****|****|****|
||||||||||||||||||||||||
||||||||||||||||||||||||
||||||||||||||||||||||||
||||||||||||||||||||||||
||||||||||||||||||||||||
67
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Multipurpose Power Line RFI Filter for Emission Control**
## S Series UL Recognized CSA Certified WES VDE Approved
**==> picture [132 x 20] intentionally omitted <==**
**----- Start of picture text -----**<br>
20VS1<br>3VS1<br>**----- End of picture text -----**<br>
## S Seriesriesiesess S Seriesriesiesess Series eriesriesiesess
## S Seriesriesiesess
- Combines Line to Ground interference rejection filters with additional circuitry to reduce Line to Line noise and transients
- Designed for use when equipment impedance at RF frequencies is high
- Effective for use with switch-mode power supplies
- Effective when used to control emissions in equipment using SCR and T2L circuits for compliance with FCC Part 15, Subpart J and EN55022, Level A, down to 150kHz
## O Ordering rdering I Information nformation
- 20 V S 6 ~~L~~ Input Input / / O Output utput S Style tyle 1 – .250 [6.3] spade terminals 6 – Threaded bolt
S S S Series eries L Leakage eakage current designation current designation V – Standard C Current urrent R Rating ating 3, 6, 10, 20 or 60A
## S Specifications pecifications
|S<br>pecifications<br>ecifications<br>cifications<br>ifications<br>fications<br>cations<br>ations<br>tions<br>ions<br>ons<br>ns<br>s<br>Specifications||
|---|---|
|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:|
||3 & 20A<br>60A|
|@120 VAC 60 Hz:|.4 mA<br>.75 mA|
|@250 VAC 50 Hz:|.7 mA<br>1.25 mA|
|Hipot rating (one minute):||
|Line to Ground:<br>Line to Line:|2250 VDC<br>1450 VDC|
|Rated Voltage (max):|250 VAC|
|Operating Frequency:|50/60 Hz|
|Rated Current:|3 to 60A|
|Operating Ambient Temperature Range||
|(at rated current Ir):|-10°C to +40°C|
|In an ambient temperature (Ta) higher than +40°C<br>the maximum operating current (Io) is calculated as<br>follows: Io = Ir (85-Ta)/45||
## E Electrical lectrical S Schematics chematics 3, 6, 10VS
**==> picture [194 x 89] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>SS<br>L a C con<br>LINE LOAD<br>**----- End of picture text -----**<br>
## 20VS
## A Available vailable P Part art N Numbers umbers
|3VS1|20VS1|
|---|---|
|6VS1|20VS6|
|10VS1|60VS6|
## 60VS
LINE LOAD
68
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Multipurpose Power Line RFI Filter for Emission Control** _(continued)_
## S Series
## C Case ase S Styles tyles
**==> picture [228 x 161] intentionally omitted <==**
**----- Start of picture text -----**<br>
S1 (3, 6, 10A)<br>B<br>s il IF |<br>i Ht "I!<br>—<—_—_ D Set<br>E<br>A =a C<br><br> <br> <br> <br>**----- End of picture text -----**<br>
**==> picture [241 x 168] intentionally omitted <==**
**----- Start of picture text -----**<br>
60VS6<br>A<br>E<br>C D<br>a<br>.415 [ 10.54 ] ref.<br>I l e ey 12]<br>_ B ait i. fo 57.15 2.25 ± .25± .01<br>ml at | ie| Ae 28.5 1.12 ref.<br><br> <br> <br>**----- End of picture text -----**<br>
~~Dimensions~~ Case Dimensions ~~Case~~ A B C D E Part No. ~~re~~ __ ** ** 3VS1 _ _ ~~Oe~~ ** ** 6VS1 ~~re~~ _ _ ** ** 10VS1 _ _ ** ** 20VS1 _ _ ** ** 20VS6 _ _ ** ** 60VS6 _ _
**==> picture [288 x 162] intentionally omitted <==**
**----- Start of picture text -----**<br>
20VS1<br>— a)<br>, 3VS1<br>E D B Ls} te)<br>6VS1<br>= rL<br>10VS1<br>2.00<br>50.8<br>A _ C 20VS1<br><br> <br> 20VS6<br> <br>**----- End of picture text -----**<br>
## 20VS6
**==> picture [231 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
B D E<br>a<br>2.00<br>50.8<br>.| C L E A =<br><br> <br> <br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
69
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Multipurpose Power Line RFI Filter for Emission Control** _(continued)_
## S Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [493 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
3VS 6VS 10VS 20VS<br>db db db db<br>100 100 100 100<br>90 90 90 90<br>80 80 80 80<br>6070 Hit 6070 a 6070 Hl 6070 a<br>50 4 |een 50 eS 50 ee 50 | | ey,<br>40 40 40 40<br>30 Pet| 30 etTe | 30 A 30 eeAl)<br>20 a | 20 LL > alll 20 see rr 20 ee ee<br>100 0.1 1 10 30 aa 100 0.1 1 10 30 ee|ea ee 100 0.1 1 10 30 ATTEhee 100 0.1 1 10 30 A|eeeeTT<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## 60VS
**==> picture [114 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
db<br>10090608070 EATA|LEAT TATTATE HtTONITE |<br>50 PT AT AN<br>40 LT ATleer1<br>30 ee<br>20 AA<br>10 AA<br>0 oe a Ty<br>0.01 0.1 1 10 30<br>Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|****|||****|****|****|****||||****||||****|****|****|****|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****||****|****|****|****|****|****|****|****|****|****|
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
70
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **High Performance B Series RFI Line Filters**
## SB Series
UL Recognized CSA Certified VDE Approved
**==> picture [197 x 37] intentionally omitted <==**
**----- Start of picture text -----**<br>
20VSB1<br>30ESB6<br>6VSB1<br>**----- End of picture text -----**<br>
## S SB B S Series eries
- Enhanced performance version of our popular B Series of RFI line filters
- Small size with enhanced performance
- 30A version half the size of other 30A filters
- Low leakage version available that meets current requirements of VDE portable equipment and non-patient care medical equipment
## O Ordering rdering I Information nformation
- 20 E SB 6 L Input Input / Output / Output Style Style 1 – .250 [6.3] spade terminals 6 – Threaded bolt
- S SB B S Series eries L Leakage eakage c current urrent d designation esignation E – Low leakage _(<0.5 mA)_ V – Standard
- C Current urrent R Rating ating 6, 10, 20 or 30A
## S Specifications pecifications
Maximum leakage current each Line to Ground:
||VSB Models|ESB Models|
|---|---|---|
|@ 120 VAC 60 Hz:<br>@250 VAC 50 Hz:|.75 mA<br>1.25 mA|.22 mA<br>.36 mA|
|Hipot rating (one minute):<br>Line to Ground:||2250 VDC|
|Line to Line:||1450 VDC|
|Rated Voltage (max):||250 VAC|
|||250 VDC|
|Operating Frequency:||50/60 Hz|
|Rated Current:||6 to 30A|
Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
## A Available vailable P Part art N Numbers umbers
|6ESB1<br>10ESB1<br>10ESB6<br>20ESB1<br>20ESB6<br>30ESB6|6VSB1<br>10VSB1<br>10VSB6<br>20VSB1<br>20VSB6<br>30VSB6|
|---|---|
## E Electrical lectrical S Schematic chematic
**==> picture [185 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>**----- End of picture text -----**<br>
71
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **High Performance B Series RFI Line Filters** _(continued)_
**==> picture [231 x 612] intentionally omitted <==**
**----- Start of picture text -----**<br>
SB Series<br>Case Styles<br>Case Styles<br>6ESB1 & 6VSB1<br>le) YL<br>B<br>| ijft<br>C D<br>E<br>ee A<br><br> <br> <br> <br>10ESB1, 10VSB1, 20ESB1 & 20VSB1<br>| Tf<br>B<br>.|<br>| fh© 9)<br>C D<br>E<br>-— = A —<br><br> <br> <br> <br>ESB6 & VSB6<br>SS<br>| amt{<br>B<br>d<br>am<br>| - IN<br>— C D<br>E<br>A<br><br> <br> <br>**----- End of picture text -----**<br>
|C<br>a<br>s<br>e<br>D<br>i<br>m<br>e<br>n<br>s<br>i<br>o<br>n<br>s<br>~~CaseDimensions~~|C<br>a<br>s<br>e<br>D<br>i<br>m<br>e<br>n<br>s<br>i<br>o<br>n<br>s<br>~~CaseDimensions~~|C<br>a<br>s<br>e<br>D<br>i<br>m<br>e<br>n<br>s<br>i<br>o<br>n<br>s<br>~~CaseDimensions~~||||
|---|---|---|---|---|---|
|Part No.|A<br>|B<br>|C<br>|D<br><br>__|E<br>|
|6ESB1,|****|****|****|****|****|
|6VSB1|__|__|__|__|__|
|10ESB1,|****|****|****|****|****|
|10VSB1|__|__|__|__|__|
|10ESB6,|****|****|****|****|****|
|10VSB6|__|__|__|__|__|
|20ESB1,|****|****|****|****|****|
|20VSB1|__|__|__|__|__|
|20ESB6,|****|****|****|****|****|
|20VSB6|__|__|__|__|__|
|30ESB6,|****|****|****|****|****|
|30VSB6|__|__|__|__|__|
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
72
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **High Performance B Series RFI Line Filters** _(continued)_
## SB Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
## ESB Models
**==> picture [163 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
6ESB1 10ESB1<br>**----- End of picture text -----**<br>
**==> picture [493 x 217] intentionally omitted <==**
**----- Start of picture text -----**<br>
6ESB1 10ESB1 10ESB6 20ESB1<br>db db db db<br>100 100 100 100<br>90 a 90 EL 90 Ee 90 _ LOM CO Loo<br>80 | 80 | | 80 a 80 CACC CIA<br>70 COTA CTI TILA 70 COTM TTT TTT Ag 70 COI CEI 70 |<br>60 OE 60 ET /\ 60 a /\ 60 CAC 1<br>50 EL aT 50 LEAT TA See 50 CCIE UT ZS * 50 CCCI Cl JN<br>4030 LTH0 ee 4030 OE 4030 COI Aen 4030 anil —'<br>20 OP PodPee | 20 LeTrlATE TTITTT TT| 20 CUT| ALO(ee 20 CUnail AAni<br>10 P26" ae | 10 ae a | 10 [ wei LI 10 WAC<br>0 0.01 0.1 1 10 30 eeri | LEI TTI 0 0.01 0.1 1 10 30 eve | CEI TAIT 0 0.01 0.1 1 10 30 Tio LI 0 0.01 0.1 1 10 30 ern<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>20ESB6 30ESB6<br>db db<br>10090 LOTTITI, A 10090 EE<br>8070 TETTn TIAN 8070 EENVA<br>60 | CN 60 EE J<br>50 CCTM FAN 50 Et WF)<br>4030 CIOTH werett| 4030 LOLCTAgaret| |<br>20 Lor Ati TT 20 a "i aTI<br>10 LAA IETE 10 20 A<br>0 0.01 0.1 1 10 30 mer | LTTE FTI 0 0.01 0.1 1 10 30 elFLT TTI<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## VSB Models
**==> picture [493 x 219] intentionally omitted <==**
**----- Start of picture text -----**<br>
6VSB1 10VSB1 10VSB6 20VSB1<br>db db db db<br>100 100 100 100<br>90 nF 90 | 90 a 90 LOM COL Loo<br>80 En 80 TAT TT 80 CUM CCT Ceri 80 CCCI CCI<br>70 THI TA 70 | DI 70 CUI ne 70 CCC 3<br>60 a 60 a ae 60 COLI JA\ 60 eT<br>4050 aTE 4050 TEoe 4050 eS 4050 CCCI CIey Aeeti NT<br>30 TIL ATT| 30 OP2 a 2 30 CIA| 30 _I Cee" iS<br>20 | 20 20 20 Caio<br>10 OP er ACL IIE NN 10 Loa A i TT Ty 10 | Ai Co 10 TT ACI<br>0 0.01 0.1 1 10 30 err rill a| TI ETE CI 0 0.01 0.1 1 10 30 PeeTE Qe| CET TTI 0 0.01 0.1 1 10 30 [ Ti0Co Lo 0 0.01 0.1 1 10 30 eriACCLI<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>20VSB6 30VSB6<br>db db<br>1009080 a a 1009080 eTEL<br>70 A | iy, 70 TL<br>60 TE TIE AAA 60 LEI TI rr a AL |<br>4050 CUeeFT cleNY 4050 e ell<br>30 LOTIL AvTI 30 LL aA TTT<br>20 ee AAT 20 LAATTTT<br>10 20 10 LATA I TE<br>0 etl | | 0 =a<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
73
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**High Performance B Series RFI Line Filters** _(continued)_
## SB Series
## P Performance erformance D Data ata _(continued)_
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|||||****|****|****|****|****|||||||||****|****|****|****|****|****||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****||****|****|****|****|****|****|****|****|****||****|****|||****|****|****|****|****|****|****|****|****|
|****|||||||||||||****|||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|****|||||||||||||****|||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
74
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **High Performance K Series RFI Line Filters for SMPS Emission Control**
## SK Series
UL Recognized CSA Certified VDE Approved
**==> picture [168 x 80] intentionally omitted <==**
**----- Start of picture text -----**<br>
SK7/7M<br>SK1<br>SK3<br>**----- End of picture text -----**<br>
## SK S Seriesriesiesess SK K S Seriesriesiesess Series eriesriesiesess
## SK S Seriesriesiesess
- Designed to reduce conducted noise to acceptable limits for equipment that must comply with FCC / EN specifications
- Utilizes significantly higher element values than the general purpose K Series which makes them better suited for equipment with Line to Ground and Line to Line conducted emissions including those with switching power supplies
- ESK6C and VSK6C incorporate separate ground circuit inductor to isolate the equipment chassis from power line ground at RF frequencies
## O Ordering rdering I Information nformation
## 10 E SK 7 M
## Suffix
M – Metric inserts _(style 7 only)_ Omit for standard or none C – Ground choke _(30ESK/VSK only)_
> I Input nput / Output / Output S Style tyle 1 – .250 [6.3] spade terminals 3 – Wire leads
6 – Threaded bolt
- 7 – IEC inlet* _(line side)_
.250 [6.3] spade terminals
_(load side)_
> S SK K S Series eries
> L Leakage eakage c current urrent d designation esignation E – Low leakage _(<0.5 mA)_ V – Standard
## S Specifications pecifications
Maximum leakage current each Line to Ground:
|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:|
|---|---|---|---|
|3<br>,<br>6<br>&<br>1<br>0<br>A<br>VSK Models<br>ESK Models<br>@120 VAC 60 Hz:<br>.4 mA<br>.21 mA<br>@250 VAC 50 Hz:<br>.7 mA<br>.36 mA<br>2<br>0<br>,<br>3<br>0<br>&<br>4<br>0<br>A<br>@120 VAC 60 Hz:<br>.75 mA<br>.3 mA<br>@250 VAC 50 Hz:<br>1.25 mA<br>.5 mA<br>Hipot rating (one minute):<br>~~3.6 &10A~~<br>~~a~~<br>~~20, 30 & 40A~~||||
|Line to Ground:|||2250 VDC|
|Line to Line:|||1450 VDC|
|Rated Voltage (max):|||250 VAC|
|Operating Frequency:|||50/60 Hz|
|Rated Current:|||3 to 40A|
|Operating Ambient Temperature Range||||
|(at rated current Ir):||-10°C to +40°C||
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
|A<br>v<br>a<br>i<br>l<br>a<br>b<br>l<br>e<br>P<br>3VSK1<br>3VSK3<br>~~Available ~~|P<br>a<br>r<br>t<br>N<br> ~~Part ~~|P<br>a<br>r<br>t<br>N<br> ~~Part ~~|N<br>u<br>m<br>b<br>e<br>r<br>s<br>3ESK1<br>3ESK3<br> ~~Numbers~~|20ESK6<br>20VSK6|
|---|---|---|---|---|
|3VSK7|||3ESK7|30ESK6|
|3VSK7M|||3ESK7M|30ESK6C|
|6VSK1|||6ESK1|30VSK6|
|6VSK3|||6ESK3|30VSK6C|
|6VSK7|||6ESK7|40VSK6|
|6VSK7M|||6ESK7M||
|10VSK1|||10ESK1||
|10VSK3|||10ESK3||
|10VSK7|||10ESK7||
|10VSK7M|||10ESK7M||
C Current urrent R Rating ating 3, 6, 10, 20, 30 or 40A
_*IEC 60320-1 C14 inlet mates with C13 connector_
75
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **High Performance K Series Filters for SMPS Emission Control** _(continued)_
## SK Series
**==> picture [123 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
E Electrical lectrical S Schematic chematic<br>**----- End of picture text -----**<br>
**==> picture [193 x 78] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>1<br>STSRE<br>= B<br>**----- End of picture text -----**<br>
**==> picture [227 x 22] intentionally omitted <==**
**----- Start of picture text -----**<br>
A AcEessories ccessories<br>G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord<br>**----- End of picture text -----**<br>
**==> picture [240 x 178] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles<br>SK1<br>B<br>fA ft [eal<br>4 IL | @al |<br>D<br>E<br>ae A C<br><br> <br> <br> <br>**----- End of picture text -----**<br>
**==> picture [50 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
SK3 (3A)<br>**----- End of picture text -----**<br>
**==> picture [400 x 338] intentionally omitted <==**
**----- Start of picture text -----**<br>
Blue Blue<br>B<br>Brown Brown<br>A Green/<br>D Yellow<br>ES E C<br><br> <br> <br>SK3 (6 & 10A)<br>Blue Blue<br>Grn/Yel<br>B<br>Brown Brown<br>ESK6 / VSK6 /<br>Ld A _ C<br>D<br>E<br><br> <br> <br>**----- End of picture text -----**<br>
76
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **High Performance K Series Filters for SMPS Emission Control** _(continued)_
## SK Series
## Case Styles _(continued)_
**==> picture [59 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
SK6 (20A)<br>**----- End of picture text -----**<br>
## SK6 (40A)
**==> picture [493 x 351] intentionally omitted <==**
**----- Start of picture text -----**<br>
D<br>E D B<br>B<br>a * ) A E<br>E 2.00<br>A 50.5<br>C A C<br> —— _ _<br> <br> <br>SK6 (30A) SK7 & SK7M<br>Tapped insert<br>D B<br>E D B<br>Te) O A n E<br>C<br>i a is ee<br>1.50<br>38.1<br>A _ C | gt<br> <br> <br> <br> <br> <br> <br>**----- End of picture text -----**<br>
## SK6C (30A)
## Recommended Panel Cutout
**==> picture [241 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
E D B<br>1.50<br>38.1<br>yp A C<br><br> <br> <br>**----- End of picture text -----**<br>
**==> picture [121 x 157] intentionally omitted <==**
**----- Start of picture text -----**<br>
.235 .157<br>R Dia. (2)<br>5.96 3.98<br>.910<br>23.11<br>1.295<br>32.89<br>1.575<br>40.01<br><br> <br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
77
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**High Performance K Series Filters for SMPS Emission Control** _(continued)_
## SK Series
## Case Dimensions ~~Case Dimensions~~
## Performance Data Performance Data
||Part No.|A<br>|B<br>|C<br>|D<br><br>__|E<br>|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss|Typical Insertion Loss||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||3VSK1,|****|****|****|****|****|Measured in closed 50 Ohm system|||||||||Measured in closed 50 Ohm system||||||||||||||||||||||||||||||
||3ESK1|__|__|__|__|__|3 & 6VSK|3 & 6VSK||||||||||||||||||3 & 6ESK|3 & 6ESK|||||||||||||||||||
|3VSK3,<br>3ESK3<br>3VSK7/7M,<br>3ESK7/7M<br>6VSK1,<br>6ESK1<br>6VSK3,||****<br>__<br>****<br>__<br>****<br>__<br>****|****<br>__<br>****<br>__<br>****<br>__<br>****|****<br>__<br>****<br>__<br>****<br>__<br>****|****<br>__<br>****<br>__<br>****<br>__<br>****|****<br>__<br>****<br>__<br>****<br>__<br>****|db<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30||db<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>0.01 0.1 1 10 30<br>0.01 0.1 1 10 30<br>Frequency in MHz<br>i?|||||||||||||0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30||0.01 0.1 1 10 30<br>Frequency in MHz<br>age|||||||||||||
|6ESK3||__|__|__|__|__||||||||||||||||||||||||||||||||||||||||
|6VSK7/7M,||****|****|****|****|****|10 & 20VSK||10 & 20VSK|||||||||||||||||10 & 20ESK||10 & 20ESK||||||||||||||||||
|6ESK7/7M||__|__|__|__|__|db<br>100|||||||||||||||||||db<br>100||||||||||||||||||||
|10VSK1,<br>10ESK1<br>10VSK3,<br>10ESK3||****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|90<br>80<br>70<br>60<br>50<br>40<br>30|||||||||||||||||||90<br>80<br>70<br>60<br>50<br>40<br>30||||||||||||||||||||
||10VSK7/7M,<br>10ESK7/7M|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|20<br>10<br>0<br>0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30||0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30||20<br>10<br>0<br>0.01 0.1 1 10 30<br>0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30||0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30||0.01 0.1 1 10 30|
||20VSK6,|****|****|****|****|****|||||||||||||Frequency in MHz|||||||||||||||||||Frequency in MHz||||||||
||20ESK6|__|__|__|__|__|30VSK|||||||||||||||||||30ESK||||||||||||||||||||
||Part No.|A<br>|B<br>|C<br>|D<br><br>__|E<br>|db<br>100<br>90<br>80|||||||||||||||||||db<br>100<br>90<br>80||||||||||||||||||||
||30VSK6,<br>30ESK6<br>30VSK6C,<br>30ESK6C|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|70<br>60<br>50<br>40<br>30<br>20<br>10|||||||||||||||||||70<br>60<br>50<br>40<br>30<br>20<br>10||||||||||||||||||||
||40VSK6|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|0<br>0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30||0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0<br>0.01 0.1 1 10 30<br>0.01 0.1 1 10 30<br>Frequency in MHz||||||||0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30||0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30<br>Frequency in MHz||||||||
|||||||__|40VSK|||||||||||||||||||||||||||||||||||||||
||||||||db|||||||||||||||||||||||||||||||||||||||
||||||||100<br>90<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0|||||||||||||||||||||||||||||||||||||||
||||||||0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30||0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30|0.01 0.1 1 10 30||0.01 0.1 1 10 30||||||||||||||||||||
||||||||||||||||||||Frequency in MHz|||||||||||||||||||||||||||
|||||||||||||||Common Mode / Asymmetrical (L-G)|||||||||||||||||||||||Common Mode / Asymmetrical (L-G)|||||||||
||||||||||||||Differential Mode / Symmetrical (L-L)|||||||||||||||||||||||||||||||||
78
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **High Performance K Series Filters for SMPS Emission Control** _(continued)_
## SK Series
## P Performance erformance D Data ata _(continued)_
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
|****|||****|****|****|****|****|||
|---|---|---|---|---|---|---|---|---|---|
|****|****||****|****|****|****|****|****|****|
|****||||||||||
|||||||||||
|||||||||||
|||||||||||
|||||||||||
|||||||||||
|****||||||||||
|||||||||||
|||||||||||
|||||||||||
|||||||||||
## Differential Mode / Symmetrical (Line to Line)
|****|||****|****|****|****|****|||
|---|---|---|---|---|---|---|---|---|---|
|****|****||****|****|****|****|****|****|****|
|****||||||||||
|||||||||||
|||||||||||
|||||||||||
|||||||||||
|||||||||||
|****||||||||||
|||||||||||
|||||||||||
|||||||||||
|||||||||||
79
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **High Performance RFI Power Line Filters for Switching Power Supplies**
## T Series
UL Recognized CSA Certified VDE Approved
## T T S Series eries
- Superior common-mode and premium differential-mode attenuation
- Smaller package sizes than the EP Series
- Size and cost-effective
- ET models can help meet very low leakage current requirements
## O Ordering rdering I Information nformation 10 E T 1
~~L~~ Input Input / / O Output utput Style Style
## S Specifications pecifications
Maximum leakage current each Line to Ground:
|3<br>,<br>6<br>&<br>1<br>0<br>A<br>~~5.6 &10A~~|ET Models|ET Models|VT Models|
|---|---|---|---|
|@120 VAC 60 Hz:|.30 mA||.75 mA|
|@250 VAC 50 Hz:|.50 mA||1.2 mA|
|1<br>5<br>&<br>2<br>0<br>A<br>@120 VAC 60 Hz:<br>@250 VAC 50 Hz:<br>15 &20A|.30 mA<br>.50 mA||1.2 mA<br>2.0 mA|
|Hipot rating (one minute):||||
|Line to Ground:|||2250 VDC|
|Line to Line:|||1450 VDC|
|Rated Voltage (max):|||250 VAC|
|Operating Frequency:|||50/60 Hz|
|Rated Current:|||3 to 20A|
|Operating Ambient Temperature Range||||
|(at rated current Ir):||-10°C to +40°C||
|In an ambient temperature (Ta) higher than +40°C<br>the maximum operating current (Io) is calculated as<br>follows: Io = Ir (85-Ta)/45||||
1 – .250 [6.3] spade terminals 3 – Wire leads
- 6 – Threaded bolt
- 7 – IEC inlet* _(line side)_ .250 [6.3] spade terminals _(load side)_
T T S Series eries
> L Leakage eakage c current urrent d designation esignation E – Low leakage _(<0.5 mA)_ V – Standard
## A Available vailable P Part art N Numbers umbers
|3ET1<br>3ET3<br>3ET7<br>6ET1<br>6ET3<br>6ET7|10ET1<br>10ET3<br>15ET1<br>15ET6<br>20ET1<br>20ET6|10VT1<br>10VT3<br>15VT1<br>15VT6<br>20VT1<br>20VT6|
|---|---|---|
C Current urrent R Rating ating 3, 6, 10, 15 or 20A
_*IEC 60320-1 C14 inlet mates with C13 connector_
80
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **High Performance RFI Filters for Switching Power Supplies** _(continued)_
## T Series
**==> picture [232 x 228] intentionally omitted <==**
**----- Start of picture text -----**<br>
E Electrical lectrical S Schematics chematics<br>3 & 6A<br>LINE LOAD<br>apCai<br>10A<br>LINE LOAD<br>Ce : a |<br>15 & 20A<br>LINE LOAD<br>**----- End of picture text -----**<br>
## C Case ase S Styles tyles
**==> picture [229 x 161] intentionally omitted <==**
**----- Start of picture text -----**<br>
T1 (3, 6, 10A)<br>B<br>1<br>B feel<br>D<br>C<br>= E ) =o<br>A<br><br> <br> <br> <br>**----- End of picture text -----**<br>
## T1 (15 & 20A)
Accessories G AccessoriesGA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord
**==> picture [241 x 306] intentionally omitted <==**
**----- Start of picture text -----**<br>
E D B<br>| — iE<br>2.00± .01<br>50.8± .25<br>T=a i <— C — |<br><br> <br> <br> <br>T3<br>Blue Blue<br>—, — Grn/Yel |<br>B<br>Brown Brown<br>A C<br>= D / i]<br>=I pl<br>E<br><br> <br> <br>A<br>**----- End of picture text -----**<br>
81
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help**
**corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **High Performance RFI Filters for Switching Power Supplies** _(continued)_
## T Series
## C Case ase S Styles tyles _(continued)_
## C Case ase D Dimensions imensions
A B C D E T6 Part No. __ ** ** 3ET1, 6ET1 | o ~~f]~~ | ~~F~~ eO | E ~~m Oo~~ _ _ ** ** E D B 3ET3, 6ET3 _ _ a ~~fl~~ | di ~~: ne~~ ** []** 3ET7, 6ET7 ~~Oe~~ _ []_ ** ** ~ 2.00 ± .01 _50.8 ± .25_ 10ET1, 10VT1 _ _ C ** ** 10ET3, 10VT3 _ _ __ __ 15ET1, 15VT1, ** ** __ T7 20ET1, 20VT1 _ _ 15ET6, 15VT6, ** ** 20ET6, 20VT6 _ _ Tapped insert ~~|~~ t __ D B ©) ~~a~~ | E A ~~—~~ C __ __ __ __
__
## Recommended Panel Cutout
**==> picture [141 x 147] intentionally omitted <==**
**----- Start of picture text -----**<br>
.235<br>R .157<br>5.96 Dia.<br>3.98<br>.910<br>23.1<br>1.295<br>32.89<br>1.575<br>40.01<br><br>**----- End of picture text -----**<br>
82
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
**High Performance RFI Filters for Switching Power Supplies** _(continued)_
## T Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
Measured in closed 50 Ohm system
**==> picture [493 x 233] intentionally omitted <==**
**----- Start of picture text -----**<br>
3ET 6ET 10ET 15ET<br>db db db db<br>100 100 100 100<br>90 90 90 90<br>80 CO] Co 80 80 COICIC 80<br>70 70 70 70<br>60 PHI IE Na 60 Teh 60 nw aati, 60<br>50 Co-SO 50 pert 50 con Co 50<br>40 2D” A en, 40 acc 40 tt 40<br>30 30 30 30<br>20 CA Ho 20 CHE 20 AEH 20<br>10 CAA AI Ce 10 IEC 10 STi ce Coo 10<br>0 0.01 0.1 1 10 30 0 0.01 0.1 1 10 30 0 0.01 0.1 1 10 30 0 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>20ET 10VT 15VT 20VT<br>db db db db<br>100 100 100 100<br>90 90 90 90<br>80 80 80 80<br>70 70 70 70<br>60 60 60 60<br>50 50 50 50<br>40 40 40 40<br>30 30 30 30<br>20 20 20 20<br>10 10 10 10<br>0 0.01 0.1 1 10 30 0 0.01 0.1 1 10 30 0 0.01 0.1 1 10 30 0 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
||****||||****|****|****|****|****|||||****||||****|****|****|****|****||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||****|****||||****|****|****|****|****|****|****||****|****||||****|****|****|****|****|****|****|
||****|||||||||||||****||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|****|||||||||||||****|||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
83
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **RFI Filter for Power Factor Corrected Power Supplies**
## U Series
UL Recognized CSA Certified VDE Approved
**==> picture [128 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
6EU1 6EUP<br>**----- End of picture text -----**<br>
## U U S Series eries
- Designed for equipment using power factor corrected power supplies
- Offers high impedance circuit to mismatch the power supply’s impedance characteristics
- Available in PC board mountable version
- All models meet low leakage current requirements
## O Ordering rdering I Information nformation
- 6 E U 1 LL Input Input / Output / Output Style Style 1 – .250 [6.3] spade terminals P – PC board pins
## S Specifications pecifications
|S<br>pecifications<br>ecifications<br>cifications<br>ifications<br>fications<br>cations<br>ations<br>tions<br>ions<br>ons<br>ns<br>s<br>Specifications||
|---|---|
|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:|
|@ 120 VAC 60 Hz:|.30 mA|
|@250 VAC 50 Hz:|.50 mA|
|Hipot rating (one minute):||
|Line to Ground:<br>Line to Line:|2250 VAC<br>1450 VDC|
|Rated Voltage (max):|250 VAC|
|Operating Frequency:|50/60 Hz|
|Rated Current:|6A|
|Operating Ambient Temperature Range||
|(at rated current Ir):|-10°C to +40°C|
|In an ambient temperature (Ta) higher than +40°C||
|the maximum operating current (Io) is calculated as|the maximum operating current (Io) is calculated as<br>follows: Io = Ir (85-Ta)/45<br>~~———.~~|
## E Electrical lectrical S Schematic chematic
LINE LOAD
U U S Series eries Leakage current designation E – Low leakage _(<0.5 mA)_ Leakage current designation C Current urrent R Rating ating 6A
## A Available vailable P Part art N Numbers umbers
6EUP 6EU1
84
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **RFI Filter for Power Factor Corrected Power Supplies** _(continued)_
## U Series
**==> picture [241 x 406] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles<br>6EU1<br>~<br>B<br>a<br>4 |2 @) |<br>D<br>— E<br>A OO a C i m<br><br> <br> <br> <br>6EUP<br>[| © ©<br>B<br>Threaded Ground pin (2)<br>.14 Inserts (3)<br>3.56<br>__ 4 .39<br>9.91<br>C<br>T i d<br>J A<br><br> <br> <br>**----- End of picture text -----**<br>
## C Case ase D Dimensions imensions
**==> picture [240 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
A B C D E<br>Part No. _ <br> <br>6EU1<br> <br>6EUP <br>suman <br>Performance Data<br>Performance Data<br>**----- End of picture text -----**<br>
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [115 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
6EU<br>db<br>100<br>90<br>oa<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>an 0.01 0.1 1 10 30<br>Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
## R Recommended ecommended P PC C B Board oard L Layout ayout
**==> picture [197 x 150] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>.157 Dia. (3) .075 Dia. (6)<br>.26<br>6.60<br>1.50 .52<br>38.1 13.21<br>.75<br>19.05<br>1.50 .79<br>38.1 20.07<br>2.10<br>53.34<br>2.99<br>75.95<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (Line to Ground)
|****|||****|****|||
|---|---|---|---|---|---|---|
|****|****|****|****<br>****|****<br>****|****|****|
||||<br>|<br>|||
|Differential Mode / Symmetrical (Line to Line)|Differential Mode / Symmetrical (Line to Line)|Differential Mode / Symmetrical (Line to Line)||Differential Mode / Symmetrical (Line to Line)|||
|****|||****||||
|****|****|****|****<br>****|****<br>****|****|****|
||||<br>|<br>|||
85
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Multipurpose Power Line RFI Filter for Emission Control**
## V and W Series
UL Recognized CSA Certified VDE Approved1
**==> picture [171 x 52] intentionally omitted <==**
**----- Start of picture text -----**<br>
VV1 / VW1<br>VV6 / VW6<br>**----- End of picture text -----**<br>
Both the V and W series are effective to control emissions in equipment using SCR and T[2] L circuits for compliance with FCC Part 15, Subpart J and EN55022, Level A, down to 150kHz
## V V S Series eriesriesiesess
## V V S Series eriesriesiesess
- Offers an N = 3 (“T”) Line to Ground impedance to common mode and an N = 5 “Dbl. Pi”) impedance for Line to Line differential mode interference
- Designed for susceptibility use when equipment impedance at RF frequencies is low
## W W S Series eriesriesiesess
## W W S Series eriesriesiesess
- Offers an N = 4 (“Dbl. L”) Line to Ground impedance for common mode and an N=5 (“Dbl. Pi”) impedance for Line to Line differential mode interference
- Designed for use when equipment impedance at RF frequencies is high
## • Two stage construction provides excellent suppression at high frequencies Ordering Information Ordering Information 20 V V 6
~~L~~ Input Input / Output / Output Style Style 1 – .250 [6.3] spade terminals 6 – Threaded bolt 7 – IEC inlet* _(line side)_ .250 [6.3] spade terminals _(load side)_ V V o or r W W S Series eries Leakage current designation Leakage current designation V – Standard C Current urrent R Rating ating 3, 6, 10 or 20A
- _*IEC 60320-1 C20 inlet mates with C19 connector_
## S Specifications pecifications
|S<br>pecifications<br>ecifications<br>cifications<br>ifications<br>fications<br>cations<br>ations<br>tions<br>ions<br>ons<br>ns<br>s<br>Specifications||
|---|---|
|Maximum leakage current each Line to Ground:<br>@ 120 VAC 60 Hz:<br>@250 VAC 50 Hz:|Maximum leakage current each Line to Ground:<br>.5 mA<br>.82 mA|
|Hipot rating (one minute):||
|Line to Ground:|2250 VDC|
|Line to Line:|1450 VDC|
|Rated Voltage (max):|250 VAC|
|Operating Frequency:|50/60 Hz|
|Rated Current:|3 to 20A*|
|Operating Ambient Temperature Range||
|(at rated current Ir):|-10°C to +40°C|
|In an ambient temperature (Ta) higher than +40°C<br>the maximum operating current (Io) is calculated as<br>follows: Io = Ir (85-Ta)/45||
## E Electrical lectrical S Schematics chematics V Series
**==> picture [218 x 143] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>~ L C Hy —_<br>W Series (3, 6 & 10A)<br>LINE LOAD<br>DAK<br>- C oe = a<br>W Series (20A)<br>LINE LOAD<br>**----- End of picture text -----**<br>
_120VW7, 20A model tested by Underwriters Laboratories to US and Canadian requirements and is VDE approved at 16A, 250VAC_
86
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Multipurpose Power Line RFI Filter for Emission Control** _(continued)_
## V and W Series
## C Case ase S Styles tyles _(continued)_ VW7
**==> picture [34 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
Threaded inserts<br>**----- End of picture text -----**<br>
## A ~~Available~~ vailable P ~~Part~~ art ~~Numbers~~ Numbers
|3VV1<br>6VV1<br>10VV1<br>20VV1<br>~~Available Part Numbers~~|~~Numbers~~|3VW1<br>3VW1<br>10VW1<br>20VW1|
|---|---|---|
|20VV6||20VW6|
|||20VW7*|
## C Case ase S Styles tyles
V1 / W1 (3, 6 & 10A)
**==> picture [139 x 89] intentionally omitted <==**
**----- Start of picture text -----**<br>
IP<br>~ q<br>B<br>D ex) |<br>E<br>A C<br>**----- End of picture text -----**<br>
**==> picture [206 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
<br> <br> <br> <br>**----- End of picture text -----**<br>
## V1 / W1 (20A)
**==> picture [231 x 253] intentionally omitted <==**
**----- Start of picture text -----**<br>
E D B<br>| Lh<br>2.00<br>50.8<br>A C<br><br> <br> <br> <br>V6 / W6<br>——— _ fFe |<br>E D B<br>2.00<br>._ 50.8 +<br>A C<br><br> <br> <br>**----- End of picture text -----**<br>
**==> picture [227 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.25<br>57.15 B<br>3 if<br>| fu ) | Lo y |<br>.047 ± .010<br>1.19 ± .25<br>5.33 ± .025<br>135.38 ± .635<br>A _ C<br><br> <br> <br> <br> <br>R Recommended ecommended Panel Panel Cutout Cutout<br>**----- End of picture text -----**<br>
**==> picture [120 x 90] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.98 .157 [Dia.] 2.30<br>58.42<br>a<br>30.99 1.22 CL 40.46 1.60<br>.75<br>19.05<br>5.56 .219 R Mounting Plane<br>2.12<br>53.85<br>**----- End of picture text -----**<br>
## C ~~Case~~ ase D ~~Dimensions~~ imensions
||Part No.|A<br>|B<br>|C<br>|D<br><br>__<br>~~—~~|E<br>|
|---|---|---|---|---|---|---|
|3VV1, 3VW1<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>~~OO~~<br>~~a~~|||||||
||6VV1, 6VW1|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
||10VV1, 10VW1|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
||20VV1, 20VW1|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
||20VV6, 20VW6<br>~~Ce~~|****<br>__<br>~~Ce~~|****<br>__<br>~~Ce~~|****<br>__<br>~~Ce~~|****<br>__<br>~~Ce~~|****<br>__<br>~~Ce~~|
||20VW7|****<br>__|****<br>__|****<br>__|****|****|
- _*20VW7, 20A model tested by Underwriters Laboratories to US and Canadian requirements and is VDE approved at 16A, 250VAC_
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
87
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Multipurpose Power Line RFI Filter for Emission Control** _(continued)_
## V and W Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [241 x 243] intentionally omitted <==**
**----- Start of picture text -----**<br>
3VV 6VV<br>db db<br>100 100<br>90 90<br>80 80<br>70 a 70<br>60 [PAH 2 60 | O——<br>50 | A 50 EE) ae<br>4030 aAU al 4030 |<br>20 20<br>10 dill 10 a 0 | ll<br>0 HAE 0 aEEE ttt<br>0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>3VW 6VW<br>db db<br>100 100<br>90 90<br>80 80<br>70 70<br>60 oir 7 60 alla NS<br>50 L TALAT 50 AC TN<br>40 | OY All 40 PP” al ll<br>30 rN) A 30 LAA Eh<br>20 20<br>10 10<br>0 CHE 0 EEE ttt<br>0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## 10VV
## 20VV
**==> picture [240 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db<br>10090 a 10090<br>80 80<br>6070 THEihn... 6070 0Tm<br>50 ee Pe 50 ea e~TNLSN<br>40 a Aae 40 ee ee<br>30 30 |<br>20 20<br>10 Loli | Cir _| 10 aril CIE<br>0 TMCFHMC 0 ACCCe<br>0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## 10VW
## 20VW
**==> picture [240 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db<br>1009080 a|ee 1009080<br>70 70<br>60 COPS 60 sui<br>50 [CP AAT 50 COA CUTa \<br>40 ne ee eell 40 pa a<br>30 erriii Con _| 30 0<br>20 20<br>10 10<br>0 HHMI 0 CH<br>0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|****|||****|****|****|****||||****|||****|****|****|****|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****||****|****|****|****|****|****|****|****|****|
|****||||||||||****|||||||||
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
|****||||||||||****|||||||||
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
88
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **High Performance, Low Cost Filter Ideal for Appliance Equipment**
## WG Series
UL Recognized CSA Certified VDE Approved
**==> picture [40 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
WG_1 Style<br>**----- End of picture text -----**<br>
## W WG G S Series eries
- Cost-effective
- Tubular design
- WGA, WGB and WGC versions designed to comply with leakage current for fixed appliances not easily moved from one place to another
- WGD, WGE and WGF versions designed to comply with leakage current requirements for appliances which may be easily moved from one place to another
- Available in a variety of styles
## O Ordering rdering I Information nformation 16 WG A 1
> I Input nput / Output / Output S Style tyle 1 – .250 [6.3] spade terminals 3 – Wire Leads 7 – RAST 5 connection
> L Leakage eakage C Current urrent & & P Performance erformance A, B & C: for fixed appliances A = Standard
B = Enhanced
C = High performance
D, E & F: for mobile appliances
D = Standard
## S Specifications pecifications
## Maximum leakage current each Line to Ground:
|A, B & C Models<br>@ 120 VAC 60 Hz:<br>.76 mA|D, E & F Models<br>.10 mA|
|---|---|
|@250 VAC 50 Hz:<br>1.27 mA|.20 mA|
|Hipot rating (one minute):<br>Line to Ground:|2250 VDC|
|Line to Line:|1450 VDC|
|Rated Voltage (max):|250 VAC|
|Operating Frequency:|50/60 Hz|
|Rated Current:|16A|
|Operating Ambient Temperature Range||
|(at rated current Ir):|-10°C to +40°C|
|In an ambient temperature (Ta) higher than +40°C<br>the maximum operating current (Io) is calculated as<br>follows: Io = Ir (85-Ta)/45||
## Electrical Schematics Electrical Schematics
L (2) U (1) GND N(4) U (3)
## With RAST 5 Connector (style 7)
L GND N
E = Enhanced
F = High performance
> W WG G S Series eries C Current urrent R Rating ating 16A
## A Available vailable P Part art N Numbers umbers
|16WGA1<br>16WGB1<br>16WGC1<br>16WGD1<br>16WGE1<br>16WGF1|16WGA3<br>16WGB3<br>16WGC3<br>16WGD3<br>16WGE3<br>16WGF3|16WGA7<br>16WGB7<br>16WGC7<br>16WGD7<br>16WGE7<br>16WGF7|
|---|---|---|
89
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **High Performance, Low Cost Filter for Appliance Equipment** _(continued)_
## WG Series
**==> picture [494 x 321] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles<br>WG_1 WG_3<br>9.80 .386 62.5 2.46 max.<br>.46 .386 2.0 max. 4.0<br>11.7 max . 9.80 50.8 101.6 [min.]<br>1.49 Dia.<br>37.8 1.49 Dia.<br>37.8<br>Est it<br>W b E-} C a | 7 ——= aE<br>P=}Ee | ON] M7 v =—<—o Con © e OO<br>a: ey ===<br><br> <br> <br> <br>WG_7 <br>9.80 .386 60.96 2.4 max. <br>8.94 .352 min. <br>1.49 Dia. <br>37.8 <br> <br>- +) (f i n<br>HA fe] (/fi*<br>== N ey<br><br> <br> []<br> <br><br><br>**----- End of picture text -----**<br>
**==> picture [41 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
WG_7 Style<br>**----- End of picture text -----**<br>
90
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **High Performance, Low Cost Filter for Appliance Equipment** _(continued)_
## WG Series
## Performance Data
## Typical Insertion Loss
Measured in closed 50 Ohm system
## All Case Styles
**==> picture [493 x 216] intentionally omitted <==**
**----- Start of picture text -----**<br>
16WGA 16WGB 16WGC 16WGD<br>db db db db<br>100 100 100 100<br>90 90 90 90<br>80 80 80 80<br>70 70 70 70<br>60 60 60 60<br>50 50 50 50<br>40 40 40 40<br>30 30 30 30<br>20 20 20 20<br>10 10 10 10<br>0 0.01 0.1 1 10 30 0 0.01 0.1 1 10 30 0 0.01 0.1 1 10 30 0 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>16WGE 16WGF<br>db db<br>100 100<br>90 90<br>80 80<br>70 70 Common Mode / Asymmetrical (L-G)<br>6050 6050 Differential Mode / Symmetrical (L-L)<br>40 40<br>30 30<br>20 20<br>10 10<br>0 0<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|||||****|****|****|****|||||||||****|****|****|****||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****|****|****||****|****|****|****|****|****|****|****|****|****|****|
|****||||||||||||****|||||||||||
||||||||||||||||||||||||
||||||||||||||||||||||||
||||||||||||||||||||||||
||||||||||||||||||||||||
||||||||||||||||||||||||
||||||||||||||||||||||||
91
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Chassis or PC Board Mountable Power Line Filters for Emission Control**
## X, Y, Z Series
UL Recognized CSA Certified VDE Approved
**==> picture [206 x 57] intentionally omitted <==**
**----- Start of picture text -----**<br>
XP / YP / ZP<br>3EX1 / 3EZ1<br>**----- End of picture text -----**<br>
## X xX, , Y Y, , Z Z S Series eries
- Compact chassis or PC board mountable
- Three levels of performance
- Complete filtering solution in minimal size
## X X S Series eriesriesiesess
## X X S Series eriesriesiesess
- Designed to bring most digital equipment (including those with switching power supplies) into compliance with FCC Part 15J, Class B conducted emission limits
## Y Y S S Series eriesriesiesess
## Y Y S S Series eriesriesiesess
- Designed to bring most digital equipment (including those with switching power supplies) into compliance with EN55022, Level A and FCC Part 15J, Class B conducted emission limits
.
## Z Z S Series eri . es
## S Specifications pecificationsecificationscificationsificationsficationscationsationstionsionsonsnss
## S Specifications pecificationsecificationscificationsificationsficationscationsationstionsionsonsnss
|S<br>pecificationsecificationscificationsificationsficationscationsationstionsionsonsnss<br>ecificationscificationsificationsficationscationsationstionsionsonsnss<br>cificationsificationsficationscationsationstionsionsonsnss<br>ificationsficationscationsationstionsionsonsnss<br>ficationscationsationstionsionsonsnss<br>cationsationstionsionsonsnss<br>ationstionsionsonsnss<br>tionsionsonsnss<br>ionsonsnss<br>onsnss<br>nss<br>s<br>Specifications||
|---|---|
|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:|
|@ 120 VAC 60 Hz:|.30 mA|
|@250 VAC 50 Hz:|.50 mA|
|Hipot rating (one minute):||
|Line to Ground:|2250 VDC|
|Line to Line:|1450 VDC|
|Rated Voltage (max):|250 VAC|
|Operating Frequency:|50/60 Hz|
|Rated Current:|1 to 6A|
|Operating Ambient Temperature Range||
|(at rated current Ir):|-10°C to +40°C|
|In an ambient temperature (Ta) higher than +40°C||
|the maximum operating current (Io) is calculated as|the maximum operating current (Io) is calculated as<br>follows: Io = Ir (85-Ta)/45|
## E Electrical lectrical S Schematic chematic
**==> picture [172 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>**----- End of picture text -----**<br>
- Designed to bring most digital equipment (including those with switching power supplies) into compliance with EN55022, Level B and FCC Part 15J, Class B conducted emission limits
## O Ordering rdering I Information nformation
3 E X 1 L I Input nput / Output / Output S Style tyle 1 – .250 [6.3] spade terminals P – PC board pins X x, , Y Y o or r Z Z S Series eries L Leakage eakage c current urrent d designation esignation E – Low leakage _(<0.5 mA)_ C Current urrent R Rating ating 1, 2, 3, 4 or 6A
|3EXP<br>3EX1<br>4EXP<br>6EXP<br>2EYP<br>3EYP<br>Available Part ~~Numbers~~|4EYP<br>1EZP<br>2EZP<br>3EZP<br>3EZ1<br>~~Numbers~~|
|---|---|
## Available Part Numbers
92
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Chassis & PC Board Mountable RFI Filters for Emission Control** _(continued)_
## X, Y, Z Series
**==> picture [494 x 495] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles C Case ase D Dimensions imensions<br>X1 & Z1 A B C D E<br>Part No. <br> <br>7 7 7 3EXP ee <br> <br>B<br> <br>3EX1<br> <br>eal,<br>4EXP <br>D C <br>E<br>| A 6EXP <br> <br><br> 2EYP <br> <br>3EYP, 4EYP <br> <br>XP, YP & ZP 1EZP <br> <br>A<br>| 2EZP, 3EZP re <br> <br> <br>3EZ1<br> <br>i<br>C<br>Recommended PC Board Layout<br>2.660<br>67.56<br>0.123 .605 1.850<br>3.12 [Min.] 15.37 46.99<br>1.050<br>26.67<br>Grounds<br>B Line Load<br>side side .350<br>8.89<br>1.190 .700<br>30.23 17.78<br>Tos) [meet<br> .245<br> 6.22<br>.150<br>3.81<br> <br>**----- End of picture text -----**<br>
93
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Chassis & PC Board Mountable RFI Filters for Emission Control** _(continued)_
## X, Y, Z Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [404 x 461] intentionally omitted <==**
**----- Start of picture text -----**<br>
3EX 4EX 6EX<br>db db db<br>10090 a 10090 | 10090 [LOL<br>80 PR 80 80 LO Le<br>70 ee 70 0 | 70 I TT<br>60 A, 60 LT ATT | | 60 ee<br>50 a) 50 PEALE SS 50 LAI CIC IN<br>40 ay ee 40 e n)e aPr 40 C CA TAI<br>30 4a | 30 | 30 IZA ane<br>20 Py 20 20 I<br>10 LAA 10 ee | a 10 pe a<br>0 0.01 0.1 1 10 30 A | 0 0.01 0.1 1 10 30 era | IL EE 0 0.01 0.1 1 10 30 CLECttlCI CI<br>Frequency in MHz Frequency in MHz Frequency in MHz<br>2EY 3EY 4EY<br>db db db<br>10090 a 10090 ee ee 10090 nn<br>80 a 80 || 80 a|<br>70 CLT C7 70 PTE | VAT | 70 a<br>60 LP ZT PTT 60 PTT ATI TAN 60 CAAA CN<br>50 Aco, 50 TEI Zettel lI 50 ae<br>40 |) 4 40 LEAT I | 40 Ann<br>30 a 30 | 30 enA<br>20 Pe | 20 a 20 A<br>10 10 10<br>0 0.01 0.1 1 10 30 0aa 0 0.01 0.1 1 10 30 L LMA | TELM TE| CI 0 0.01 0.1 1 10 30 4ati<br>Frequency in MHz Frequency in MHz Frequency in MHz<br>1EZ 2EZ 3EZ<br>db db db<br>100 100 100<br>90 a 90 a | 90 | LOL LoLd<br>80 inp. ——-...| ae 80 a 80 nN<br>70 CLT 7M TIN 70 LTA TST 70 CI<br>60 LTA 60 EE) Nw 60 COZeAAT<br>50 RT 50 50 eS<br>40 ey eeA iea 40 aEY Aee 40 aee Ag<br>30 A 30 Oe 30 |<br>20 7 20 20 AC<br>10 77 10 7 10 AC<br>0 0.01 0.1 1 10 30 4 a 0 0.01 0.1 1 10 30 aEMEee| EI FCI 0 0.01 0.1 1 10 30 aCVE COI Ci<br>Frequency in MHz Frequency in MHz Frequency in MHz<br>Common Mode / Asymmetrical (L-G)<br>Differential Mode / Symmetrical (L-L)<br>**----- End of picture text -----**<br>
94
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**1**
## **Chassis & PC Board Mountable RFI Filters for Emission Control** _(continued)_
## P Performance erformance D Data ata _(Continued)_
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
||||****|****|****|****||||||||****|****|****|****||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****||****|****|||||****|****|****|****|****|
|****||||||||||****|||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
|****||||||||||****|||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
|****||||||||||****|||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
95
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Engineering Notes**
96
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**2**
## **2. Three Phase Filters — Table of Contents**
|T<br>h<br>r<br>e<br>e<br>P<br>Three|T<br>h<br>r<br>e<br>e<br>P<br>Three|P<br>h<br>a<br>s<br>e<br>S<br>e<br>l<br>e<br>c<br>t<br>o<br>r<br>C<br>h<br>a<br>r<br>t<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>9<br>7<br> Phase Selector Chart ........c0ccccccccccceccescsvcesscessss:O/|
|---|---|---|
||A Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98||
||ADT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101|ADT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101|
||AYA Series|AYA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104|
||AYC Series|AYC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108|
||AYO Series|AYO Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111|
||BCF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113|BCF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113|
||CFN Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116|CFN Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116|
||FCD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118|FCD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118|
## **Three Phase Selector Chart**
**==> picture [218 x 252] intentionally omitted <==**
**----- Start of picture text -----**<br>
Delta Delta WYEor<br>Wiring or Delta<br>ONLY WYE Wiring<br>Try The Try The<br>CFN All Series AYO<br>Series Are Listed in Series<br>300-600A Ascending 3-20A<br>Page 116 Performance Page 111<br>from<br>BCF AYA<br>Series Good Series<br>7-180A to 16-100A<br>Page 113 Page 104<br>FCD | AYC<br>Series Series<br>Better<br>6-230A 16-200A<br>Page 118 to Page 108<br>SeriesADT | SeriesA<br>3-200A Best 20-60A<br>Page 101 Page 98<br>NEW<br>NEW<br>Now to 230A<br>**----- End of picture text -----**<br>
97
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **High Performance 3-phase RFI Filters for WYE Applications**
## A Series
UL Recognized CSA Certified VDE Approved
## A A S Series eries
- For 3-phase, four wire, WYE Applications
- Filters each of the three lines plus the neutral and ground line
- Both common mode and differential mode suppression from 50kHz to 30MHz
- Effective for both balanced and unbalanced loads
- Ground choke included
- Optional end bell kits available to shield input and output terminals
- AYP single stage for lower noise environments
- AYT dual stage provides highest performance
## O Ordering rdering I Information nformation
45 AYT 6 C ~~L~~ S Suffix uffix C – Ground Choke I Input nput / / O Output utput S Style tyle 6 – Threaded 1/4 – 20 bolt Series designation AYP – Single Stage Series designation AYT – Dual Stage Current Rating Current Rating 20, 30, 45 or 60A
## S Specifications pecifications
|S<br>pecifications<br>ecifications<br>cifications<br>ifications<br>fications<br>cations<br>ations<br>tions<br>ions<br>ons<br>ns<br>s<br>Specifications||
|---|---|
|Maximum leakage current, each Line to Ground:|Maximum leakage current, each Line to Ground:|
|@ 120 VAC 60 Hz:<br>@ 250 VAC 50 Hz:|1.4 mA<br>3.4 mA|
|Hipot rating (one minute):<br>Line to Ground:<br>Neutral to Ground:|1500 VAC<br>1500 VAC|
|Line to Neutral:|1450 VDC|
|Rated Voltage (max):||
|Phase to Phase:<br>Phase to Neutral / Ground:|440 VAC<br>250 VAC|
|Operating Frequency:|50/60 Hz|
|Rated Current:|20 to 60A|
|Operating Ambient Temperature Range||
|(at rated current Ir):<br>-10°C to +40°C||
|In an ambient temperature (Ta) higher than +40°C||
|the maximum operating current (Io) is calculated as<br>follows: Io = Ir (85-Ta)/45||
## E Electrical lectrical Schematics Schematics AYP6C Models
**==> picture [236 x 136] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>A A<br>CNB F L T L LEE CELCE NCB<br>LINE LOAD<br>GND GND<br>**----- End of picture text -----**<br>
98
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**2**
## **High Performance 3-phase RFI Filters for WYE Applications** _(continued)_
## A Series
## E Electrical lectrical S Schematics chematics _(continued)_
## C Case ase S Style tyle
## AYT6C Models
**==> picture [241 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>A A<br>B B<br>C C<br>N N<br>LINE LOAD<br>GND GND<br>**----- End of picture text -----**<br>
## A Available vailable P Part art N Numbers umbers
|20AYP6C<br>30AYP6C<br>45AYP6C<br>60AYP6C|20AYT6C<br>30AYT6C<br>45AYT6C<br>60AYT6C|
|---|---|
**==> picture [168 x 165] intentionally omitted <==**
**----- Start of picture text -----**<br>
C A<br>E<br>D B 4<br>E S J /<br>Terminals: Mounting studs:<br>1/4 x 20 (10) No. 8-32 (8)<br>Torque: 6.33 [56 lbf] N-m ± [-][in ± 2] .23<br>**----- End of picture text -----**<br>
## A Accessories ccessories
Mounting bracket kit with captive nuts: A AAZO9 A400: 20A & 30A versions A AA405 A405: 45A & 60A versions
**==> picture [73 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
AA406A<br>~ AA400<br>**----- End of picture text -----**<br>
**==> picture [32 x 51] intentionally omitted <==**
**----- Start of picture text -----**<br>
AA407A<br>AA405<br>**----- End of picture text -----**<br>
Protective cover for use with mounting bracket: ( _For Europe only. Limited availability in other regions)_ A AA406A A406A: 20A & 30A versions A AA407A A407A: 45A & 60A versions
End bell kit (bracket and cover) with captive nuts: A AA406 A406: 20A & 30A versions A AA407 A407: 45A & 60A versions
**==> picture [63 x 28] intentionally omitted <==**
**----- Start of picture text -----**<br>
AA406 / AA407<br>Kits includes both<br>bracket and cover<br>**----- End of picture text -----**<br>
## Additional captive nuts:
## C Case ase D Dimensions imensions
||Part No.|A*<br>|B<br>|C<br>|D<br><br>__|E<br><br>__|
|---|---|---|---|---|---|---|
|||****|****|****|****|****|
||20AYP6C|__|__|__|__|__|
|||****|****|****|****|****|
||30AYP6C|__|__|__|__|__|
||45AYP6C|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
||60AYP6C|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|||****|****|****|****|****|
||20AYT6C|__|__|__|__|__|
|****<br>****<br>****<br>****<br>****<br>~~SH~~|||||||
||30AYT6C|__|__|__|__|__|
||45AYT6C|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|||****|****|****|****|****|
||60AYT6C|__|__|__|__|__|
__ __
A AA4O1 A401: 10 nuts
99
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**High Performance 3-phase RFI Filters for WYE Applications** _(continued)_
## A Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
## 20AYP6C 30AYP6C
## 45AYP6C
## 60AYP6C
**==> picture [494 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db db db<br>100 100 100 100<br>90 90 90 90<br>80 80 80 80<br>70 ee 70 HH 70 EE EH 70 HEE HH<br>60 60 60 60<br>50 50 50 50<br>40 40 40 40<br>30 30 30 30<br>20 PC ate 20 : foes 20 fer ae 20 Spate<br>10 10 10 10<br>0 PESTER) 0.01 0.1 0.15 1 10 30 0 0.01 0.1 0.15 1 10 30 TRESS 0 DIESE 0.01 0.1 0.15 1 10 30 STP) 0 0 CUTER 0.01 0.1 0.15 1 10 30 ST<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## 20AYT6C
## 30AYT6C
## 45AYT6C
## 60AYT6C
**==> picture [494 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db db db<br>100 100 100 100<br>90 90 90 90<br>80 oe a 80 2 80 Hamma 80 oo<br>70 70 70 70<br>60 60 60 60<br>50 ea mate 50 | aa 50 st ea an 50<br>40 40 40 40<br>30 eC 30 Cr 30 | iat 30 Ht<br>20 20 20 20<br>10 10 10 10<br>0 0.01 0.1 0.15 1 10 30 0 0.01 0.1 0.15 1 10 30 0 0.01 0.1 0.15 1 10 30 0 0.01 0.1 0.15 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Measured in closed 50 Ohm system
## AYP6C
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|****|||****|****|****|****||||****|||****|****|****|****|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****||****|****|****|****|****|****|****|****|****|
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
## AYT6C
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|****|||****|****|****|****||||****|||****|****|****|****|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****||****|****|****|****|****|****|****|****|****|
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
100
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**2**
## **High Performance High Current 3-phase Delta RFI Filters**
## ADT Series
## UL Recognized
## A ADT DT S Series eries
- Designed for very high insertion loss for Delta three phase, three wire applications
- Available with common or differential mode coils
## O Ordering rdering I Information nformation
100 ADT 6 S L Suffix Suffix S – Differential mode coils Omit if none I Input nput / / O Output utput S Style tyle 6 – Threaded bolt A ADT DT S Series eries C Current urrent R Rating ating 63, 100, 160 or 200A
## A ~~Available~~ vailable P ~~Part~~ art ~~Numbers~~ Numbers
|63ADT6|63ADT6S|
|---|---|
|100ADT6|100ADT6S|
|160ADT6|160ADT6S|
|200ADT6|200ADT6S|
## S Specifications pecifications
Maximum leakage current at 277 VAC 60 Hz, each Line to Ground:
ADT6: 1.3 A 63ADT6S: 2.6 A 100, 160, 200ADT6S 4.6 A
Hipot rating (one minute): Line to Ground: 2210 VDC Line to Line: 2158 VDC Rated Voltage (max): Phase to Phase: 480 VAC Phase to Ground: 277 VAC Operating Frequency: 50/60 Hz Rated Current: 63 to 200A Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
## E Electrical lectrical S Schematics chematics
## 63ADT6
**==> picture [217 x 105] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>—<br>A A<br>f C yy<br>B i B<br>C C<br>**----- End of picture text -----**<br>
101
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **High Performance High Current 3-phase Delta RFI Filters** _(continued)_
## ADT Series
## E Electrical lectrical S Schematics chematics _(continued)_
## 100, 160 & 200 ADT6
**==> picture [242 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>A A<br>B B<br>C C<br>**----- End of picture text -----**<br>
## ADT6S
**==> picture [242 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>A A<br>B B<br>C C<br>**----- End of picture text -----**<br>
**==> picture [240 x 339] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Style tyle<br>A<br>2.00<br>F<br>1.00<br>| _ ]<br>ta ea,<br>mal |F im e |<br>G G<br>7 t if y| ip 't<br>1.18 x 0.56 Slot E 0.75 x 0.44 Slot<br>(2x) 2.0 Max. (6x) 0.69 Typ. (2x)<br>—fa _ba : 3/8-16 Thread<br>fu n] Fi fa C (7x)<br>See Note y Mounting<br>ff fo 4 Bracket<br>H<br>0.75 0.75 J<br>(2x) 0.75<br>K<br>(2x) CL CL B<br>D<br>(2x)<br>CL CL<br>Line Load<br> <br> <br> <br>**----- End of picture text -----**<br>
## C Case ase D Dimensions imensions
|Part No.|A<br>|B<br>|C<br>|D<br><br>__|E<br>|F<br><br>__|G<br><br>__|H<br><br>__|J<br><br>__|K<br>|
|---|---|---|---|---|---|---|---|---|---|---|
||****|****|****|****|****|****|****|****|****|****|
|63ADT6|__|__|__|__|__|__|__|__|__|__|
||****|****|****|****|****|****|****|****|****|****|
|63ADT6S|__|__|__|__|__|__|__|__|__|__|
||****|****|****|****|****|****|****|****|****|****|
|100ADT6|__|__|__|__|__|__|__|__|__|__|
||****|****|****|****|****|****|****|****|****|****|
|100ADT6S|__|__|__|__|__|__|__|__|__|__|
||****|****|****|****|****|****|****|****|****|****|
|160/200ADT6|__|__|__|__|__|__|__|__|__|__|
||****|****|****|****|****|****|****|****|****|****|
|160/200ADT6S|__|__|__|__|__|__|__|__|__|__|
102
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**2**
**High Performance High Current 3-phase Delta RFI Filters** _(continued)_
## ADT Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [428 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
63ADT6 100ADT6 160ADT6 200ADT6<br>**----- End of picture text -----**<br>
**==> picture [493 x 185] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db db db<br>100 100 100 100<br>90 90 90 90<br>80 80 80 80<br>70 70 70 70<br>60 60 60 60<br>4050 Te 4050 4050 ee 4050 ee<br>30 30 30 30<br>20 20 20 20<br>10 10 10 10<br>0 0.01 0.1 1 10 100Frequency in MHz 300 0 0.01 0.1 1 10 100Frequency in MHz 300 0 0.01 0.1 1 10 100Frequency in MHz 300 0 0.01 0.1 1 10 100Frequency in MHz 300<br>63ADT6S 100ADT6S 160ADT6S 200ADT6S<br>db db db db<br>100 100 100 100<br>90 90 90 90<br>80 80 80 80<br>70 70 70 70<br>60 60 60 60<br>50 50 50 50<br>4030 ATS 4030 ASS 4030 A 4030 A<br>20 20 20 20<br>10 10 10 10<br>0 0.01 0.1 1 10 100Frequency in MHz 300 0 0.01 0.1 1 10 100Frequency in MHz 300 0 0.01 0.1 1 10 100Frequency in MHz 300 0 0.01 0.1 1 10 100Frequency in MHz 300<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
||||****|****|****|||||||****|****|****|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****||****|****|****|****|****|****|****|****|
| ||||||||| ||||||||
| ||||||||| ||||||||
| ||||||||| ||||||||
| ||||||||| ||||||||
| ||||||||| ||||||||
| ||||||||| ||||||||
| ||||||||| ||||||||
| ||||||||| ||||||||
103
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **3-phase WYE RFI Power Line Filters**
## AYA Series
## UL Recognized*
**==> picture [110 x 30] intentionally omitted <==**
**----- Start of picture text -----**<br>
—_ 25AYA6A<br>**----- End of picture text -----**<br>
## AYA SA S Seriesriesiesess AYA YA SA S Seriesriesiesess Series eriesriesiesess
## AYA SA S Seriesriesiesess
- For 3-phase, four wire, WYE applications
- Cost-effective, universal 3-phase filters
- Good attenuation over the complete frequency range of 10kHz to 30MHz
- Two different mounting styles available
## O Ordering rdering I Information nformation
## S Specifications pecifications
Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: 1.62 mA @ 250 VAC 50 Hz: 2.82 mA Hipot rating (one minute): Line to Ground: 1500 VAC Line to Line: 1450 VDC Rated Voltage (max): Phase to Phase: 440 VAC Phase to Ground: 250 VAC Operating Frequency: 50/60 Hz Rated Current: 16 to 100A* Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as follows: Io = Ir ~~~~ (85-Ta)/45
## 36 AYA 6 A
**==> picture [150 x 182] intentionally omitted <==**
**----- Start of picture text -----**<br>
S Suffix uffix<br>A – Flange Mounted<br>(for threaded bolt style only)<br>Omit for bulkhead mount<br>or for Terminal Blocks<br>(flange mount only)<br>I Input nput / / O Output utput S Style tyle<br>6 – Threaded bolt<br>10 – Terminal block<br>(flange mount only)<br>A AYA YA S Series eries<br>C Current urrent R Rating ating<br>16, 25, 36, 50, 63 or 100A<br>**----- End of picture text -----**<br>
## A ~~Available~~ vailable P ~~Part~~ art ~~Numbers~~ Numbers
|Flange Mount<br>~~Available Part Numbers~~|Bulkhead Mount<br>~~Numbers~~|
|---|---|
|16AYA6A<br>16AYA10<br>25AYA6A<br>36AYA6A<br>36AYA10<br>50AYA6A<br>63AYA6A<br>63AYA10<br>100AYA6A|16AYA6<br>25AYA6<br>36AYA6<br>50AYA6|
_*UL Approvals for all models except: 16AYA10, 36AYA10, 63AYA10, 63AYA6, 63AYA6A and 100AYA6A_
104
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**2**
## **3-phase WYE RFI Power Line Filters** _(continued)_
## AYA Series
## E Electrical lectrical S Schematic chematic
**==> picture [241 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>A A<br>B B<br>C C<br>N N<br>GND GND<br>:<br>**----- End of picture text -----**<br>
**==> picture [236 x 223] intentionally omitted <==**
**----- Start of picture text -----**<br>
AYA6 (Bulkhead mount with screw terminals)<br>A<br>D<br>2.95 ± 0.01<br>B 75.0 ± 0.3<br>I E: —— :<br>C 1.73 ± 0.01<br>44.0 ± 0.3<br>ok | __| —_<br> <br> <br> <br> <br> <br>**----- End of picture text -----**<br>
## C Case ase S Style tyle
**==> picture [191 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
AYA6A (Flange mount with screw terminals)<br>**----- End of picture text -----**<br>
**==> picture [233 x 184] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>D<br>4.92 ± 0.02 E B<br>125.0 ± 0.5<br>C<br>2.76 ± 0.012<br>70.0 ± 0.3<br> <br> <br> <br> <br> <br>**----- End of picture text -----**<br>
**==> picture [214 x 283] intentionally omitted <==**
**----- Start of picture text -----**<br>
16AYA10<br>C<br>+i f<br>B E<br>2.76 ± 0.012<br>70.0 ± 0.3<br>D<br>A<br>E<br> <br> <br> <br> <br>**----- End of picture text -----**<br>
105
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **3-phase WYE RFI Power Line Filters** _(continued)_
## AYA Series
36AYA10 C
## Case Dimensions
**==> picture [493 x 195] intentionally omitted <==**
**----- Start of picture text -----**<br>
A B C D E*<br>Part No.<br> <br>16AYA6 /A <br>25AYA6 /A <br>OO<br>B E 36AYA6 /A <br>50AYA6 /A <br>63AYA6 /A <br>= 100AYA6A <br>2.76 ± 0.012 <br>70.0 ± 0.3 16AYA10 <br>D<br> <br>A 36AYA10<br>= —— <br> <br> <br> 63AYA10<br> <br>**----- End of picture text -----**<br>
63AYA10
**==> picture [240 x 251] intentionally omitted <==**
**----- Start of picture text -----**<br>
C<br>c s<br>B E<br>4.53 ± 0.012<br>115.0 ± 0.3<br>D<br>A<br>==<br> <br> <br> <br> <br>**----- End of picture text -----**<br>
106
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**2**
## **3-phase WYE RFI Power Line Filters** _(continued)_
## AYA Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
**==> picture [493 x 228] intentionally omitted <==**
**----- Start of picture text -----**<br>
16AYA 25AYA 36AYA 50AYA<br>db db db db<br>100 100 100 100<br>90 90 90 90<br>80 80 80 80<br>70 70 70 70<br>60 60 60 60<br>4050 aLT AILALAiLL 4050 A | AAW ES 4050 LULT AAUA| UTI 4050 A7 | |<br>30 2 | 30 AAT 30 TAA 30 WA<br>20 20 20 20<br>10 10 10 10<br>0 TECHIE 0 a 0 Pai 0 aati IE<br>0.01 0.1 1 10 30 Fal 0.01 0.1 1 10 30 HAP} 0.01 0.1 1 10 30 Dee eet 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>63AYA 100AYA<br>db db<br>100 100<br>90 90<br>80 80<br>70 70<br>60 60<br>50 50<br>40 40<br>30 30<br>20 20<br>10 10<br>0 0<br> 0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|****|||****|****|****|****||||****|||****|****|****|****|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****||****|****|****|****|****|****|****|****|****|
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
107
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **3-phase WYE RFI Power Line Filters for High Noise Applications**
## AYC Series
## UL Recognized*
**==> picture [39 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
150AYC10B<br>**----- End of picture text -----**<br>
## S Specifications pecifications
## AYC SC S Seriesriesiesess AYE YC SC S Seriesriesiesess Series eriesriesiesess
## AYC SC S Seriesriesiesess
- For 3-phase, four wire, WYE applications
Maximum leakage current each Line to Ground:
|• Very high attenuation|120 VAC 60Hz<br>16A<br>62 mA||277 VAC 50Hz<br>106 mA|
|---|---|---|---|
|• Low leakage current|25 & 36A<br>68 mA||118 mA|
|• Ideal for EMC troubleshooting and refurbishing in|63A<br>74 mA||128 mA|
|• Touch safe terminals provide easy connections|80, 100 & 150A<br>74 mA<br>180, 200A<br>111 mA||129 mA<br>192 mA|
|and prevent inadvertent contact for safety in the|Hipot rating (one minute):|||
|most demanding applications|Line to Ground:<br>Line to Line:||1850 VDC<br>1850 VDC|
|m<br>a<br>t<br>i<br>o<br>n<br>Information|Line to Neutral:||1450 VDC|
|150 AYC 10 B -95|Rated Voltage (max):<br>Phase to Phase:||480 VAC|
||Phase to Ground:||277 VAC|
|T<br>e<br>r<br>m<br>i<br>n<br>a<br>l<br>B<br>l<br>o<br>c<br>k<br>O<br>p<br>t<br>i<br>o<br>n<br>Terminal Block Option|Operating Frequency:||50/60 Hz|
|-95 – 95mm terminal block<br>_available on 150A only_|Rated Current:||16 to 200A|
|Omit for standard terminals|Operating Ambient Temperature Range||Operating Ambient Temperature Range|
||(at rated current Ir):|-10°C to +40°C||
|F<br>i<br>l<br>t<br>e<br>r<br>T<br>y<br>p<br>e<br>B – Single stage<br>Filter Type|In an ambient temperature (Ta) higher than +40°C<br>the maximum operating current (Io) is calculated as<br>follows: Io = Ir ~~~~(85-Ta)/45|||
|I<br>n<br>p<br>u<br>t<br>/<br>O<br>u<br>t<br>p<br>u<br>t<br>S<br>t<br>y<br>l<br>e<br>10 – Terminal block<br>Input /Output<br>Styl<br>nput /<br>Output<br>Style|E<br>l<br>e<br>c<br>t<br>r<br>i<br>c<br>a<br>l<br>S<br>c<br>h<br>e<br>m<br>a<br>t<br>i<br>c<br>;<br>.<br>Electrical Schematic|||
|A<br>Y<br>C<br>S<br>e<br>r<br>i<br>e<br>s<br>AYCSeries||||
- Very high attenuation
- Low leakage current
- Ideal for EMC troubleshooting and refurbishing in the field
- Touch safe terminals provide easy connections and prevent inadvertent contact for safety in the most demanding applications
## O Ordering rdering I Information nformation
## 150 AYC 10 B -95
**==> picture [493 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>C Current urrent R Rating ating A A<br>16, 25, 36, 63, 80, 110,<br>150, 180 or 200A B B<br>C C<br>Available Part Numbersvailable Part Numbersailable Part Numbersilable Part Numberslable Part Numbersable Part Numbersble Part Numbersle Part Numberse Part Numbers Part Numbersart Numbersrt Numberst Numbers Numbersumbersmbersbersersrss<br>N N<br>16AYC10B 110AYC10B<br>Available 25AYC10B Part Numbers 150AYC10B GND “iit GND<br>36AYC10B 150AYC10B-95<br>63AYC10B 180AYC10B<br>80AYC10B 200AYC10B<br>*All except 200AYC10B<br>**----- End of picture text -----**<br>
## Available Part Numbersvailable Part Numbersailable Part Numbersilable Part Numberslable Part Numbersable Part Numbersble Part Numbersle Part Numberse Part Numbers Part Numbersart Numbersrt Numberst Numbers Numbersumbersmbersbersersrss
108
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**2**
## **3-phase WYE RFI Filters for High Noise Applications** _(continued)_
## AYC Series
## C Case ase S Styles tyles 16, 25, 36, 63AYC10B
**==> picture [96 x 290] intentionally omitted <==**
**----- Start of picture text -----**<br>
ol B D<br>E<br>A<br>C<br>ASI B D<br>AS<br>o8<br>E<br>A<br>C<br>**----- End of picture text -----**<br>
## 80, 110, 150AYC10B / -95
## 180, 200AYC10B
**==> picture [155 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
ESS B D<br>SI<br>a<br>es E E<br>A<br>|<br>C<br>**----- End of picture text -----**<br>
## C Case ase D Dimensions imensions
|Part No.<br>A<br>B<br>C<br>D<br>E<br><br><br><br><br><br>__<br>16AYC10B<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>25AYC10B<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>~~_~~<br>~~——_——~~<br>~~a~~|
|---|
|36AYC10B<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__|
|63AYC10B<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__|
|80, 110 &<br>150AYC10B<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>150AYC10B-95<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>180AYC10B<br>200AYC10B<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>~~——____—_—~~|
## Terminals
|Part No.<br>Terminal<br>Size<br>Torque max.<br>lbf-in [N-m]<br>Ground<br>M5<br>26.58 [_3.0_]<br>~~—_—~~<br>~~a~~|Part No.<br>Terminal<br>Size<br>Torque max.<br>lbf-in [N-m]<br>Ground<br>M5<br>26.58 [_3.0_]<br>~~—_—~~<br>~~a~~|Part No.<br>Terminal<br>Size<br>Torque max.<br>lbf-in [N-m]<br>Ground<br>M5<br>26.58 [_3.0_]<br>~~—_—~~<br>~~a~~|Part No.<br>Terminal<br>Size<br>Torque max.<br>lbf-in [N-m]<br>Ground<br>M5<br>26.58 [_3.0_]<br>~~—_—~~<br>~~a~~|
|---|---|---|---|
|16AYC10B|Line / Load|4mm²<br>terminal block|7.08 [_0.8_]|
|25AYC10B|Ground<br>Line / Load|M5<br>6mm²<br>terminal block|26.58 [_3.0_]<br>15.93 [_1.8_]|
||Ground|M5|26.58 [_3.0_]|
|36AYC10B<br>63AYC10B<br>80, 110,|Line / Load<br>Ground<br>Line / Load<br>Ground|10mm²<br>terminal block<br>M6<br>16mm²<br>terminal block<br>M10|15.93 [_1.8_]<br>53.1 [_6.0_]<br>20.35 [_2.3_]<br>177.0 [_20.0_]|
|150AYC10B<br>150AYC10B-95<br>180AYC10B<br>200AYC10B|Line / Load<br>Ground<br>Line / Load|50mm²<br>terminal block<br>M10<br>95mm²<br>terminal block|70.80 [_8.0_]<br>177.0 [_20.0_]<br>177.0 [_20.0_]|
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
109
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **3-phase WYE RFI Filters for High Noise Applications** _(continued)_
## AYC Series
## Performance Data
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [493 x 260] intentionally omitted <==**
**----- Start of picture text -----**<br>
16AYC10B 25AYC10B 36AYC10B 63AYC10B<br>db db db db<br>100 100 100 100<br>90 90 90 90<br>80 80 80 80<br>70 70 70 70<br>60 60 60 60<br>50 50 50 50<br>40 40 40 40<br>30 30 30 30<br>20 20 20 20<br>10 10 10 10<br>0 0 0 0<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>80AYC10B 110AYC10B 150AYC10B 180, 200AYC10B<br>db db db db<br>100 100 100 100<br>90 90 90 90<br>80 80 80 80<br>70 70 70 70<br>60 60 60 60<br>50 50 50 50<br>40 AT 40 40 40<br>30 30 30 30<br>20 20 20 20<br>10 10 10 10<br>0 ByRR 0 0 0<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz I a Frequency in MHz GE SEB Frequency in MHz ait Frequency in MHz<br>Common Mode / Asymmetrical (L-G)<br>Differential Mode / Symmetrical (L-L)<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
||||****|****|****|****|||||||****|****|****|****|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****||****|****|****|****|****|****|****|****|****|
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
||||||||||||||||||||
110
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**2**
## **Compact Low Current 3-phase WYE RFI Filters**
## AYO Series
## UL Recognized CSA Certified VDE Approved
## S Specifications pecifications
## AYO SO S Seriesriesiesess AYO YO SO S Seriesriesiesess Series eriesriesiesess
## AYO SO S Seriesriesiesess
- For 3-phase, four wire, WYE applications
Maximum leakage current each Line to Ground:
|@ 120 VAC 60 Hz:<br>@ 250 VAC 50 Hz:<br>Hipot rating (one minute):<br>Line to Ground:<br>Line to Line:<br>Rated Voltage (max):<br>Phase to Phase:<br>Phase to Neutral / Ground:<br>Operating Frequency:<br>Rated Current:|3, 6, 10A<br>2.0 mA<br>3.0 mA|20A<br>3.5 mA<br>5.5 mA<br>1500 VAC<br>1450 VDC<br>440 VAC<br>250 VAC<br>50/60 Hz<br>3 to 20A|
|---|---|---|
- Filters each of the three lines plus neutral
- Good for attenuation beginning at 100kHz
- Space saving design
- Low leakage current
- Easy to connect terminals
## O Ordering rdering I Information nformation
10 AYO 1 Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C LL I Input nput / / O Output utput Style Style In an ambient temperature (Ta) higher than +40°C 1 – 0.25 [6.3] spade terminals the maximum operating current (Io) is calculated as follows: Io = Ir ~~~~ (85-Ta)/45 A AYO YO S Series eries C Current urrent Rrrent Rrent Rent Rnt Rt R R Rating atingtingingngg E Electrical lectrical Sectrical Sctrical Strical Srical Sical Scal Sal Sl S S Schematic chematichematicematicmaticaticticicc 3, 6, 10 or 20A
> C Current urrent Rrrent Rrent Rent Rnt Rt R R Rating atingtingingngg E Electrical lectrical Sectrical Sctrical Strical Srical Sical Scal Sal Sl S S Schematic chematichematicematicmaticaticticicc 3, 6, 10 or 20A LINE LOAD oO
> A ~~Available~~ vailable P ~~Part~~ art ~~Numbers~~ Numbers C ~~4~~ 3AYO1 6AYO1 N N 10AYO1 20AYO1 ~~———— htt~~
111
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Compact Low Current 3-phase WYE RFI Filters** _(continued)_
## AYO Series
> C Case ase S Style tyle A D et] \ic (els) | B e| 5B |(@s)| ~~|~~ C _——s E __ __ __ __ __
## C Case ase D Dimensions imensions
|Part No.<br>AYO Series<br>~~_———$.2~~|A<br><br>****<br>__|B<br>C<br>D<br><br><br><br>__<br>****<br>****<br>****<br>__<br>__<br>__<br>~~ee~~|E<br><br>****<br>__|
|---|---|---|---|
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [493 x 138] intentionally omitted <==**
**----- Start of picture text -----**<br>
3AYO1 6AYO1 10AY01 20AYO1<br>db db db db<br>100 100 100 100<br>90608070 ||| 90608070 aa| 90608070 CeFEEE otot 90608070 |||<br>50 50 50 50<br>40 40 40 40<br>30 30 30 30<br>20 oT Ce | 20 eer I 20 Leger Till 20 errr<br>10 a 10 10 tt Cl 10 POi<br>0 0.1 1 10 30 Hilee:a / AMGat SEIS 0 0.1 1 10 30 LeLei irmn F 0 0.1 1 10 30 EuAoni aot StH 0 0.1 1 10 30 nlLei aularoe7 |<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>Common Mode / Asymmetrical (L-G)<br>Differential Mode / Symmetrical (L-L)<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
|****|||****|****|****|||****|||****|****|****||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****||****|****|****|****|****|****|****|
||||||||||||||||
||||||||||||||||
||||||||||||||||
||||||||||||||||
112
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**2**
## **Compact 3-phase Delta RFI Filters for Universal Applications**
## BCF Series
## UL Recognized VDE Approved
## B BCF CF S Series eries
- Designed for universal applications
- Compact book-form design
- Low weight
- Insulated, high quality safety terminals for input and output
- Cost-effective design
- Good common and differential mode performance below 100kHz
- Applications include; 3-phase inverters, converters, variable speed motor drives and process automation equipment
- Touch safe terminals provide easy connections and prevent inadvertent contact for safety in the most demanding applications
## O Ordering rdering I Information nformation
## S Specifications pecifications
Maximum leakage current each Line to Ground*: @ 277 VAC 50 Hz: 30 mA
- _*If 2 phases are interrupted, this leakage current may rise to a significantly higher level_
Hipot rating (one minute): Line to Ground: 1850 VAC Line to Line: 1850 VDC
Rated Voltage (max): Phase to Phase: 480 VAC Phase to Ground: 277 VAC Operating Frequency: 50/60 Hz Rated Current: 7 to 180A Operating Ambient Temperature Range (at rated current Ir): -10°C to +50°C In an ambient temperature (Ta) higher than +50°C
the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/35
## 55 BCF 10
L_ Input Input / / O Output utput Style Style 10 – Terminal block
## Electrical Schematic Electrical Schematic
LINE LOAD
> B BCF CF S Series eries
C Current urrent R Rating ating 7, 16, 30, 42, 55, 75, 100, 130 or 180A
## Available Pailable Pilable Plable Pable Pble Ple Pe P Partrtt Numbersumbersmbersbersersrss Available vailable Pailable Pilable Plable Pable Pble Ple Pe P Partrtt Numbersumbersmbersbersersrss Part artrtt Numbersumbersmbersbersersrss Numbers Numbersumbersmbersbersersrss
## Available Pailable Pilable Plable Pable Pble Ple Pe P Partrtt Numbersumbersmbersbersersrss
|7BCF10|16BCF10|
|---|---|
|30BCF10|42BCF10|
|55BCF10|75BCF10|
|100BCF10|130BCF10|
|180BCF10||
113
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**Compact 3-phase Delta Filters for Universal Applications** _(continued)_
## BCF Series
## C Case ase S Style tyle
## Terminals
**==> picture [228 x 177] intentionally omitted <==**
**----- Start of picture text -----**<br>
H<br>F<br>D<br>A<br>C<br>E<br>B<br>L1 L1<br>Ic) oR<br>L2 L2<br>L3 L3<br>G<br>**----- End of picture text -----**<br>
|Terminals|||
|---|---|---|
||Ground|Line/Load|
|PartNo.|Terminals|Terminals|
|7BCF10, 16BCF10|M5|4mm²|
|30BCF10|M5|10mm²|
|42BCF10|M6|10mm²|
|55BCF10|M6|16mm²|
|75BCF10|M6|25mm²|
|100BCF10, 130BCF10|M10|50mm²|
|180BCF10|M10|95mm²|
## C Case ase D Dimensions imensions
|Part No.|A|B|C|D|E|F|G|H|
|---|---|---|---|---|---|---|---|---|
||||||||||
||****|****|****|****|****|****|****|****|
|7BCF10|__|__|__|__|__|__|__|__|
||****|****|****|****|****|****|****|****|
|16BCF10|__|__|__|__|__|__|__|__|
||****|****|****|****|****|****|****|****|
|30BCF10|__|__|__|__|__|__|__|__|
||****|****|****|****|****|****|****|****|
|42BCF10|__|__|__|__|__|__|__|__|
||****|****|****|****|****|****|****|****|
|55BCF10|__|__|__|__|__|__|__|__|
||****|****|****|****|****|****|****|****|
|75BCF10|__|__|__|__|__|__|__|__|
||****|****|****|****|****|****|****|****|
|100BCF10|__|__|__|__|__|__|__|__|
||****|****|****|****|****|****|****|****|
|130BCF10|__|__|__|__|__|__|__|__|
||****|****|****|****|****|****|****|****|
|180BCF10|__|__|__|__|__|__|__|__|
114
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**2**
**Compact 3-phase Delta Filters for Universal Applications** _(continued)_
## BCF Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [493 x 221] intentionally omitted <==**
**----- Start of picture text -----**<br>
7BCF10 16BCF10 30BCF10 42BCF10<br>db db db db<br>100 100 100 100<br>90 LTT TAN TTI 7 90 eo | 90 LETTE TA | TI 90 ll LT<br>80 ININ UTIE| 80 80 80<br>70 70 70 70<br>60 60 60 60<br>50 Ht 50 50 50 1<br>40 T 40 Yh NITE 40 i EE 40 “Hl NTE<br>30 30 30 30<br>20 TTI TUTTE Ng 20 a 20 A Tv TTT NY 20 Zi TTTUTTI<br>10 a 10 LEAT ET TTI TI 10 LEAT TT TTI 1 10 ATTET PE<br>0 0 0 0<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>55BCF10 75BCF10 100BCF10 130BCF10<br>db db db db<br>100 100 100 100<br>90 90 90 90<br>80 80 80 80<br>70 70 70 70<br>60 60 60 60<br>50 i Nal 1 50 tH Al EH 50 i a 50<br>4030 [ 4030 Legenw TT 4030 4030<br>20 20 A TE TTTT TINATING | 20 ffYELTI TTTTINTING 20<br>10 10 10 10<br>0 0 0 0<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## 180BCF10
**==> picture [168 x 21] intentionally omitted <==**
**----- Start of picture text -----**<br>
Common Mode / Asymmetrical (L-G)<br>Differential Mode / Symmetrical (L-L)<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
**==> picture [114 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>0.01 0.1 1 10 30<br>Frequency in MHz<br>**----- End of picture text -----**<br>
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
|****||||****|****|****|****||||||****||||****|****|****|****|||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****||||||****|****|****|****|****|||****||||||****|****|****|****|****||
||<br>|||||||||||||<br>|||||||||||
||||||||||||||||||||||||||
||<br>|||||||||||||<br>|||||||||||
||||||||||||||||||||||||||
||<br>|||||||||||||<br>|||||||||||
||||||||||||||||||||||||||
||<br>|||||||||||||<br>|||||||||||
||||||||||||||||||||||||||
||<br>|||||||||||||<br>|||||||||||
115
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3-phase Delta Power Line Filter for High Voltage Applications**
## CFN Series
## UL Recognized*
## C CFN FN S Series eries
- Universal high current filter
- Suitable for industrial applications including; motor drives, inverters, converters, uninterruptible power supplies and mining equipment
## S Specifications pecifications
Maximum leakage current at 10% unsymmetrical mains Line to Ground (3 Phase WYE Center tapped)*:
- @ 120 VAC 60 Hz: 5.0 mA
- @ 277 VAC 50 Hz: 9.6 mA
- _*If 2 phases are interrupted, this leakage current may rise to a significantly higher level_
Hipot rating (one minute): Line to Ground: 2210 VDC Line to Line: 2158 VDC
Rated Voltage (max): Phase to Phase: 480 VAC Phase to Ground: 277 VAC Operating Frequency: 50/60 Hz Rated Current: 300 to 600A
## O Ordering rdering I Information nformation
400 CFN 12 Rated Current: 300 to 600A LL Input Input / / O Output utput Style Style Operating Ambient Temperature Range 12 – Copper bus bar (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C C CFN FN S Series eries the maximum operating current (Io) is calculated as ~~a~~ follows: Io = Ir ~~~~ (85-Ta)/45 C Current urrent R Rating ating 300, 400, 500, 600A
## E Electrical lectrical S Schematic chematic
## A Available vailable P Part art N Numbers umbers
|300CFN12|400CFN12|
|---|---|
|500CFN12|600CFN12|
**==> picture [241 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 L1<br>L2 C CT L2<br>L3 i Cc |p C |e de L3<br>| i = Leth<br>PE PE<br>**----- End of picture text -----**<br>
_*400CFN12 only_
116
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**2**
## **3-phase Delta Power Filter for High Voltage Applications** _(continued)_
## CFN Series
## C Case ase S Style tyle
**==> picture [450 x 257] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>D1<br>8.27 8.27<br>PE<br>L1 L1<br>_| L |i L a i —_ 3.94<br>E CL L2 NI OA L2 F G 4.72 B<br>E | D<br>L3 L3<br>J OO _ | ae<br>PE<br>CL ae 5.0<br>M5 Insert (4 places)<br>C <br> <br>2.52 <br> <br> <br>D2<br>**----- End of picture text -----**<br>
## C Case ase D Dimensions imensions
**==> picture [482 x 51] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|A|B|C|D1|D2|E|F|G|H|
|Part No.|||
||||||||||
||||||||||
|300-600CFN12|
||||||||||
**----- End of picture text -----**<br>
## P Performance erformance D Data ata
## Typical Insertion Loss
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Measured in closed 50 Ohm system
## 300-600CFN12
Common Mode / Asymmetrical (Line to Ground)
**==> picture [451 x 123] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|db|
|100|
|90|||
|8070||||||||||
|60||||||||||||
|50|
|40|
|30|
|2010|Differential Mode / Symmetrical (Line to Line)|
|0|
|0.01 0.1 1 10 30|
|Frequency in MHz|||
||||||||||
|Common Mode / Asymmetrical (L-G)|
||||||||||||
**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
117
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **3-phase Delta External Power Line Filter for Frequency Converters**
## FCD Series
## UL Recognized
**==> picture [28 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
6FCD10<br>**----- End of picture text -----**<br>
## F FCD CD S Series eries
- Suitable to meet the latest EMC standards
- Insulated safety terminals
- Suitable for EMC troubleshooting in the field
- Very high attenuation
- High insertion loss
- BS models optimized for very high insertion loss
- BS models suitable for infeed/regenerative (ER) applications
- Touch safe terminals provide easy connections and prevent inadvertent contact for safety in the most demanding applications
## O Ordering rdering I Information nformation
## 150 FCD 10 BS -95
T Terminal erminal B Block lock O Option ption -95 – 95mm terminal block _available on 150A only_ omit for standard terminals
F Filter ilter T Type ype B – Single stage BS – High performance Single stage. Omit for dual stage
## S Specifications pecifications
Maximum leakage current voltage drop to virtual N to PE/V:
|Maximum leakage current<br>voltage drop to virtual N to PE/V:||
|---|---|
|6FCD10:|.26 mA/V|
|12 & 16FCD10:|.45 mA/V|
|25, 36 & 50FCD10:|.52 mA/V|
|12 & 16FCD10B:|.46 mA/V|
|25& 36FCD10B:|.52 mA/V|
|50FCD10B:|.57 mA/V|
|80 & 110FCD10B:|.62 mA/V|
|150FCD10B:|.63 mA/V|
|180 & 230FCD10B:|.92 mA/V|
|FCD10BS:|3.25 mA/V|
|Hipot rating (one minute):||
|Line to Ground:|2250 VDC|
|Line to Line:|1450 VDC|
|Rated Voltage (max):||
|Phase to Phase:|480 VAC|
|Phase to Neutral / Ground:|277 VAC|
|Operating Frequency:|50/60 Hz|
|Rated Current:|6 to 230A|
|Operating Ambient Temperature Range||
|(at rated current Ir):|-10°C to +40°C|
|In an ambient temperature (Ta) higher than +40°C||
|the maximum operating current (Io) is calculated as<br>follows: Io = Ir (85-Ta)/45||
## E Electrical lectrical S Schematics chematics
## 6FCD10
I Input nput / / O Output utput S Style tyle 10 – Terminal Block
FCD Series Current Rating 6, 12, 16, 25, 36, 50, 80, 110, Current Rating 150, 180 or 230A
**==> picture [186 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power line __ Device<br>C _<br>al a / |<br>PE PE<br>**----- End of picture text -----**<br>
118
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**2**
## **3-phase Delta External Filter for Frequency Converters** _(continued)_
## FCD Series
## E Electrical lectrical S Schematics chematics _(continued)_
## 12 to 50A FCD10
**==> picture [202 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power line Device<br>L1 L1<br>L2 L2<br>L3 g reta JW L3<br>PE PE<br>**----- End of picture text -----**<br>
## A Available vailable P Part art N Numbers umbers
|6FCD10<br>12FCD10<br>16FCD10<br>25FCD10<br>36FCD10<br>50FCD10|12FCD10B<br>16FCD10B<br>25FCD10B<br>36FCD10B<br>50FCD10B<br>80FCD10B<br>110FCD10B<br>150FCD10B<br>150FCD10B-95<br>180FCD10B<br>230FCD10B|50FCD10BS<br>80FCD10BS<br>110FCD10BS<br>150FCD10BS<br>150FCD10BS-95<br>180FCD10BS<br>230FCD10BS|
|---|---|---|
## 12 to 50A FCD10B
**==> picture [202 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power line Device<br>L1 L1<br>L2 L2<br>C<br>L3 L3<br>fi t t t<br>PE t t PE<br>**----- End of picture text -----**<br>
## 80 to 230A FCD10B
**==> picture [204 x 102] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power line Device<br>L1 L1<br>L2 L2<br>L3 r ete L3<br>E T U A L<br>PE PE<br>**----- End of picture text -----**<br>
## FCD10BS
**==> picture [202 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power line Device<br>L1 L1<br>L2 L2<br>L3 L3<br>T ol<br>PE PE<br>**----- End of picture text -----**<br>
**==> picture [202 x 410] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles<br>6 to 50A FCD10 & FCD10B<br>Slots: .260<br>6.61<br>ae<br>as<br>B D P| [al<br>i fa<br>u f f Hf<br>F<br>E<br>C<br>i<br>A<br>——4<br>80 to 150A FCD10B<br>50 to 150A FCD10BS<br>Slots: .260<br>6.61<br>ar<br>B D He Gt<br>q s o£<br>F<br>E<br>a 150FCD10B-95Terminal Block<br>C<br>A<br>**----- End of picture text -----**<br>
119
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **3-phase Delta External Filter for Frequency Converters** _(continued)_
## FCD Series
## C Case ase S Styles tyles _(continued)_ 180 to 230FCD10B\BS
## C Case ase D Dimensions imensions
|Part No.<br>6FCD10<br>—|A<br>B<br>C<br><br><br><br>****<br>****<br>****<br>__<br>__<br>__|A<br>B<br>C<br><br><br><br>****<br>****<br>****<br>__<br>__<br>__|A<br>B<br>C<br><br><br><br>****<br>****<br>****<br>__<br>__<br>__|D<br>E<br>F<br><br>__<br><br><br>__<br>****<br>****<br>****<br>__<br>__<br>__|D<br>E<br>F<br><br>__<br><br><br>__<br>****<br>****<br>****<br>__<br>__<br>__|D<br>E<br>F<br><br>__<br><br><br>__<br>****<br>****<br>****<br>__<br>__<br>__|
|---|---|---|---|---|---|---|
|12FCD10/10B<br>16FCD10/10B<br>25FCD10/10B<br>36FCD10/10B<br>50FCD10/10B<br>~~|~~<br>~~)—~~|****<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>__<br>****<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>__<br>~~a~~||||||
||****<br>****||****|****|****|****|
|50FCD10BS<br>__<br>__<br>__<br>__<br>__<br>__<br>80FCD10B/BS<br>110FCD10B/BS<br>150FCD10B/BS<br>****<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>__<br>~~SS~~|||||||
|150FCD10B-95|****|****|****|****|****|****|
|150FCD10BS-95|__<br>__<br>__<br>__<br>__<br>__||||||
|180FCD10B/BS|****<br>****||****|****<br>****<br>****|||
|230FCD10B/BS|__<br>__<br>__<br>__<br>__<br>__||||||
**==> picture [251 x 235] intentionally omitted <==**
**----- Start of picture text -----**<br>
.260<br>Slots:<br>6.61 Center slot on<br> 180 & 230A only<br>“WT a —<br>ca|e<br>ics fy |<br>B D<br>ic Pel<br>‘lo ff oj)<br>arm Le A y<br>Ly | (HY<br>a 9 9 OT<br>F<br>= |<br>E<br>F nl U<br>C CH] a8,<br>1<br>U a<br>A<br>**----- End of picture text -----**<br>
## Terminals
|Terminals||||
|---|---|---|---|
||||Torque max.|
|Part No.|Terminal|Size|lbf-in[N-m]|
||Ground|8-32|20.7 [_2.34_]|
|6FCD10|Line/Load|4mm²<br>terminal block|7.08 [_0.8_]|
|12FCD10/10B|Ground|M5|26.58 [_3.0_]|
|16FCD10/10B|Line/Load|4mm²<br>terminal block|7.08 [_0.8_]|
|25FCD10/10B|Ground|M5|26.58 [_3.0_]|
|36FCD10/10B|Line/Load|6mm²<br>terminal block|15.93 [_1.8_]|
||Ground|M5|26.58 [_3.0_]|
|50FCD10/10B<br>50FCD10BS<br>80 to 150FCD10B|Line/Load<br>Ground<br>Line/Load<br>Ground|10mm²<br>terminal block<br>M10<br>16mm²<br>terminal block<br>M10|15.93 [_1.8_]<br>88.5 [_10.0_]<br>20.36 [_2.3_]<br>88.5 [_10.0_]|
|80 to 150FCD10BS|Line/Load|50mm²<br>terminal block|70.80 [_8.0_]|
|150FCD10B/BS-95|Ground|M10|88.5 [_10.0_]|
|180FCD10B/BS<br>230FCD10B/BS|Line/Load|95mm²<br>terminal block|177.0 [_20.0_]|
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
## 6FCD10 12FCD10
**==> picture [240 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db<br>100 100<br>90 90<br>80 80<br>70 70<br>60 60<br>50 50<br>40 40<br>30 30<br>20 eee 20 Ts<br>10 10<br>0 0.01 0.1 1 10 30 0 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
120
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**2**
## **3-phase Delta External Filter for Frequency Converters** _(continued)_
## FCD Series P Performance erformance D Data ata _(continued)_ Typical Insertion Loss _(continued)_ Measured in closed 50 Ohm system
**==> picture [493 x 553] intentionally omitted <==**
**----- Start of picture text -----**<br>
16FCD10 25FCD10 36FCD10 50FCD10<br>db db db db<br>100 100 100 100<br>9080 iCO aaN 9080 |Ot AO,——=—SeS 9080 hhhOh _—iS>—STATAO, 9080 TallaCOAT |<br>70 70 70 70<br>60 SUSE TESS 60 PIN 60 PN 60 ET TTTSeTINTS<br>50 Hae 50 7 50 50<br>40 CA 40 AES = 40 EES 40 ecm<br>30 Pi Ci 30 7 AN | | || 30 7 AN || | 30 AAI CI]<br>20 7 | 20 ZA ne 20 ZA ne 20 40<br>10 COO CO I E C OIe 7 10 CIC7 Ce CI ]| 10 |7 CI 10 PI4<br>0 0.01 0.1 1 10 30 COO CAI Co 0 0.01 0.1 1 10 30 CCCI Eni IF 0 0.01 0.1 1 10 30 | 0 0.01 0.1 1 10 30 CCCIFan CI7<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>12FCD10B 16FCD10B 25FCD10B 36FCD10B<br>db db db db<br>100 100 100 100<br>90 |) 90 | eee 90 hh == 90 Cn eS<br>80 0 0 an 80 RY 2001 | 80 SE a AE, 80 COALS<br>70 70 70 70<br>60 ay Al ARa> 60 a A 60 HOHE 60 ee<br>4050 AEA)Access) 4050 GATE = 4050 AAI IES 4050 AEEIS<br>3020 AGG)CT [(R001] COI|CI 3020 AFAZA CIneI 3020 CCISeriVOU) Ce CICI 3020 7FoonAY 7<br>10 COO 10 10 10 |<br>0 0.01 0.1 1 10 30 COO CAICOI CooCOI 0 0.01 0.1 1 10 30 |CIC CIC] 0 0.01 0.1 1 10 30 CCCI|Een IF 0 0.01 0.1 1 10 30 CCCI|Fen 7<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>50FCD10B 80FCD10B 110FCD10B 150FCD10B<br>db db db db<br>100 100 100 100<br>90 CO Ae 90 COO APS 90 TO AT 90 =...<br>80 CO 80 80 80 S|<br>70 COA ZI7 Ciea 70 OTeOCT STTIETING N 70 B72OE TTIauntieSSMNG 70 APTSCAT<br>60 COA ACI CI 60 EY A) A 60 COZZI CIS 60 CVI7 SSN<br>50 All 50 50 50 ZC CoS<br>40 00) A7 A|| 40 0OP AYA) 40 eyCAAll |Cn 40 CZi)CoC]<br>30 AON 30 ANAT TIE CIE 30 oo AB! | 30 NAT<br>20 7A ||| REE | 20 AI I 20 7 A | 20 VAR||CI<br>10 | 10 fC Cee CI 10 AI Ce CI] 10 CI CC<br>0 0 0 0<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>180FCD10B 230FCD10B 50/80/110FCD10BS 150FCD10BS<br>db db db db<br>100 100 100 100<br>90 CO A CO 90 TI A 90 PT 90 ee<br>80 CON TINS 80 B72 any, SE 80 07a 80 EY’ 6 |<br>70 70 70 70<br>60 Of foe NE 60 HHS 60 9 All A 60 ANI<br>50 HAs «=| 50 eeai 50 50<br>40 VA 40 SS 40 AI I 40 ZEA<br>30 ABA 30 LACY CIEI 30 |A | 30 LCIAO CECINCI<br>20 AT | 20 V7 I 20 | 20 I<br>10 COO 10 10 10 Ce CI<br>0 0.01 0.1 1 10 30 COO CAIOIE COICo7 0 0.01 0.1 1 10 30 CCCIACI CeEni CI]IF 0 0.01 0.1 1 10 30 | 0 0.01 0.1 1 10 30 CCCIAFan 7<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>180FCD10BS 230FCD10BS<br>db db<br>100 100<br>9080 CLAT ese 9080 COLUYAA oo<br>6070 A ee 6070 HAHNA Common Mode / Asymmetrical (L-G)<br>50 JI, 50 ~ Differential Mode / Symmetrical (L-L)<br>40 77 IEC CIES | CAS 40 7 All|, _<br>302010 COO||COI COI 302010 7CCIICee CICIE<br>0 0.01 0.1 1 10 30 COO CAI Coo 0 0.01 0.1 1 10 30 |Cee CIC]<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
121
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **3-phase Delta External Filter for Frequency Converters** _(continued)_
## FCD Series
## P Performance erformance D Data ata _(continued)_
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|||||****|****|****|****||||||||****|****|****|****|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****||****|****|****|****|****|****|****||****|****||****|****|****|****|****|****|****|
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
122
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**2**
## **Engineering Notes**
123
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Engineering Notes**
124
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **3. Power Inlet Filters & Power Entry Modules — Table of Contents**
|I<br>n<br>t<br>r<br>o<br>d<br>u<br>c<br>t<br>i<br>o<br>n<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>INTPTOGUCTION<br>2... ccc cece|I<br>n<br>t<br>r<br>o<br>d<br>u<br>c<br>t<br>i<br>o<br>n<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>INTPTOGUCTION<br>2... ccc cece|I<br>n<br>t<br>r<br>o<br>d<br>u<br>c<br>t<br>i<br>o<br>n<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>INTPTOGUCTION<br>2... ccc cece|I<br>n<br>t<br>r<br>o<br>d<br>u<br>c<br>t<br>i<br>o<br>n<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>INTPTOGUCTION<br>2... ccc cece|I<br>n<br>t<br>r<br>o<br>d<br>u<br>c<br>t<br>i<br>o<br>n<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>INTPTOGUCTION<br>2... ccc cece|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br> rece cece|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br> rece cece|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br> rece cece|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br> rece cece|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br> rece cece|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br> rece cece|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>1<br>2<br>6<br> cece vvcecccccsssssevvvvceevesss<br>ILO|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>1<br>2<br>6<br> cece vvcecccccsssssevvvvceevesss<br>ILO|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>1<br>2<br>6<br> cece vvcecccccsssssevvvvceevesss<br>ILO|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>1<br>2<br>6<br> cece vvcecccccsssssevvvvceevesss<br>ILO|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>1<br>2<br>6<br> cece vvcecccccsssssevvvvceevesss<br>ILO|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>1<br>2<br>6<br> cece vvcecccccsssssevvvvceevesss<br>ILO|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>1<br>2<br>6<br> cece vvcecccccsssssevvvvceevesss<br>ILO|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>1<br>2<br>6<br> cece vvcecccccsssssevvvvceevesss<br>ILO|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|S<br>e<br>l<br>e<br>c<br>t<br>o<br>r<br>C<br>h<br>a<br>r<br>t<br>.<br>Selector Chart|||.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br> .....ccc cc||.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>1<br>2<br>8<br> ccc cccsssssvvvvvccscccescssvevessssssevee<br>12S||||||||||||||
|P<br>o<br>w<br>e<br>r<br>E<br>n<br>t<br>r<br>y<br>M<br>o<br>d<br>u<br>l<br>e<br>S<br>e<br>l<br>e<br>c<br>t<br>o<br>r<br>G<br>Power Entry Module Selector||||||G<br>u<br>i<br>d<br>e<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>1<br>2<br>9<br> Guide ........0ccc0ccececsecersseess<br>ld|||||||||||||
||C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130||C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130|C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130|C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130|C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130|||C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130||C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130|C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130||C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130||C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130||C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130|
||CU Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134||||||||
||EBF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138||EBF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138||EBF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138|EBF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138|EBF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138||EBF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138||EBF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138||||||||
||EC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141|||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141|
||ED Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144|||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144|
||EEA & EEB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148||||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|
||EAS & EBS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|||EAS & EBS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|EAS & EBS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|EAS & EBS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|||EAS & EBS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148||EAS & EBS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|EAS & EBS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148||||EAS & EBS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148||EAS & EBS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|
||EAH & EBH Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148||||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148|
||EEJ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||EEJ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||EEJ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153|EEJ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153|EEJ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||EEJ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||EEJ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||||||||
||EJH & EJHS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153|EJH & EJHS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153|EJH & EJHS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||EJH & EJHS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153|EJH & EJHS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153|EJH & EJHS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||EJH & EJHS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||EJH & EJHS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||||||||
||EJM & EJMS Models||EJM & EJMS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||||||||
||EJS Models|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153||||||||
||EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160||EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160|EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160|EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160||||EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160|EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160|EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160|EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160|EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160|EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160|EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160|EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160|EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160|EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160|
||EJT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163||EJT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163||EJT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163|EJT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163|EJT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163||EJT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163||EJT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163||||||||
||GG & HG Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166|||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166|||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166||||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166|
||H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169||H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169||H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169|H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169|H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169||H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169||H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169||||||||
||J Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172||||||||
||L Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175||||||||
||LA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180||LA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180|LA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180|LA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180|LA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180|||LA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180||LA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180|LA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180||LA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180||LA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180||LA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180|
||M Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183||M Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183||M Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183|M Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183|M Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183||M Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183||M Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183||||||||
||P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192||||||||
||SR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201||SR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201|SR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201|SR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201|SR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201|||SR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201||SR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201|SR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201||SR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201||SR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201||SR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201|
||SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203|SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203||SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203|||SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203|SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203||SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203||SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203|SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203|SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203|SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203|SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203|SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203|SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203|
125
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Introduction**
Power Inlet Filters feature power sockets integrated with EMI filters enclosed in RFI jackets. The AC power socket complies with IEC an standard to assure worldwide power cord compatibility. These filters are available in a wide variety of filtering, shielding, mounting and termination styles that provide the most compact and cost-effective inlet filtering available. For DC power inlet filters, see the DC section.
_Corcom EJS Series IEC Inlet RFI Filter_
Power Entry Modules incorporate power sockets with filtering, fuses, switching and voltage selection in a variety of configurations to reduce cost, space and labor. The power sockets comply with IEC standards to assure worldwide AC power cord compatibility. For DC power entry modules, see the DC section.
Equipment marketed worldwide, must operate with
- Multiple different wall plugs and sockets
_Corcom P Series CHAMELEON Power Entry Module_
- Different fuse standards in America and Europe
- Different voltages in different regions
- On/Off switching options
- Different EMI requirements in different regions
The combinations are endless. Your equipment needs a single solution.
TE Connectivity’s power entry modules can provide ONE mechanical solution for a variety of power entry needs. Each series supports several different configurations to suit the market requirements. Each starts with an international standard power cord connector, and includes options for fusing, voltage selection, switching, and filtering. Selecting one power entry module series simplifies the mechanical design, and each version within the series replaces the cost and labor of up to including up to five individual parts in the equipment bill of materials. With hundreds of different combinations of power entry functions, the modules in this catalog offer a cost-effective solution to the power entry needs of many systems. It is easy to select the module that best serves your needs.
126
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Introduction** _(continued)_
The selector guides on the next two pages help you configure the best power entry module for your application. Just select options from this menu of five categories.
I |EC60320 EC60320 ~~-1 -~~ 1 S Socket ocket – Common to all modules, the 60320-1 universal socket allows your equipment to be used in every country. Simply select a power cord with a mating IEC 60320-1 plug on one end, and a regionally appropriate plug on the other.
F Fusing using O Options ptions – North American (¼” x 1¼” 3AG) or Metric (5mm x 20mm) or both? One fuse or two?
> V Voltage oltage S Selection election O Options ptions – 4-voltage, 2-voltage, or 1-voltage? Multitap? Center-tap? Dual primary?
P Power ower S Switch witch – Yes or no? Double pole (DPST) or single (SPST)? These power entry module switches feature international on - off markings, current ratings up to 15A and high inrush current.
S Shielding hielding – reduce radiated emissions through the panel cut-out by selecting a module with a shield (optional on the C, CU, M and P).
F Filtering iltering o options ptions – Choice of six filter circuits (all with low leakage current to meet international standards) to fit specific filtering objectives:
- G General eneral p purpose urpose (C, CU, GG, J, LA, M and P) – most cost-effective, for susceptibility and for high-frequency “clean-up” when used with a boardlevel filter
- M Medical edical (in C, GG, L, M, and P series) – for medical equipment
- E Emissions/Linear missions/Linear (in L and P series) – capable of bringing most digital equipment with linear power supplies into FCC compliance
- E Emissions/SMP missions/SMPS ~~S-~~ F FCC CC (in P, LA and M series) – capable of bringing most digital equipment with switch-mode power supplies into FCC Class B compliance
- E Emissions/SMP missions/SMPS ~~S-~~ V VDE DE (in P, LA and M series) – capable of bringing most digital equipment with switch-mode power supplies into VDE level B (as well as FCC Class B) compliance
Want more filtering options? Select a general purpose or an unfiltered module (C, CU, J, L, M, P, or SR series) and wire it up connect it to the load through one of the many Corcom chassis-mounted filter of your choice from the choices found in this comprehensive catalog. TE’s Corcom product engineers can also design a custom filter for your specific applicaiton.
Available accessories expand your options even further. A Corcom product sales engineer can assist you with selecting the right filter for your application.
Having arrived at the best possible combination of power entry elements, TE’s worldwide agency approvals will help ease your product through the necessary safety agencies. File numbers and Safety Agency information is listed in Section 7.
127
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Selector Chart**
**==> picture [425 x 533] intentionally omitted <==**
**----- Start of picture text -----**<br>
Integrated IEC60320-1<br>Power Socket<br>4<br>Additional<br>No Features YES<br>Power inlet only Required? Requires switch,<br>with or without fuseholder and/or<br>filtering voltage selection<br>For Power Entry Module<br>Medical Integrated Functions<br>Application<br>Yes No Voltage<br>Switching Fuseholder<br>Select<br>Try The Try The C<br>Series<br>H SR 1-15A<br>Series Series Page 130<br>1-15A 15A<br>Page 169 Page 201 CU GG<br> Series* Series**<br>EJH SRB 1-15A 1-10A<br>Series Series Page 134 Page 166<br>1-20A 15A<br>Page 153 Page 203 L<br>Series<br>EJM EF 2-6A<br>Series Series Page 175<br>1-15A 1-15A<br>Page 153 Page 160 M<br>Series<br>EEJ / EJS 3-6A<br>Series Page 183<br>1-20A<br>Page 153 P<br>Series<br>EBF 3-10A<br>Series Page 192<br>1-10A<br>Page 138 Available with or without filtering**<br>ED for medical* and/or non-medical applications.<br>Series<br>1-15A<br>Page 144<br>EC *CU Series not available for Medical versions<br>Series **GG Series not available without filtering<br>1-10A<br>Page 141<br>EJT<br>Series<br>1-20A<br>Page 163<br>Unfiltered<br>NEW<br>New Styles<br>**----- End of picture text -----**<br>
128
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Power Entry Module Selector Guide**
**==> picture [492 x 628] intentionally omitted <==**
**----- Start of picture text -----**<br>
Unfiltered Filtered Options<br>Series<br>Product Max. Current Product Max. Current Filter On/Off Voltage Fuse<br>Photo Rating Photo Rating Type Switch Selections Holder<br>Eee<br>Medical &<br>Yes<br>C 15A 10A General N/A N/A<br>DPST<br>Purpose<br>NEW<br>jee<br>General Yes<br>CU 15A 15A N/A N/A<br>Purpose SPST<br>NEW<br>e e|<br>Medical &<br>Filtered<br>GG 10A General N/A N/A Metric<br>Only<br>Purpose<br>o eeee<br>Medical & Single North<br>L 6A 6A General OptionalDPST or4 Americanor<br>Purpose Metric<br>fe|<br>Medical,<br>General Single, North<br>M 6A 6A Switch ModePurpose & OptionalDPST 2 or4 AmericanMetricor<br>Power Supply<br>Be Medical,<br>General | North<br>P 10A 10A Switch ModePurpose & Optional Single Americanor<br>Power Supply DPST or Metric<br>2<br>pie New High Performance versions in PE and PM Mounting Styles | |<br>N/A = Not Available<br>Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to<br>are metric equivalents. Dimensions are shown for reference purposes only. te.com/help<br>Specifications subject to change. corcom.com<br>**----- End of picture text -----**<br>
129
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Power Entry Module with Switch**
## C Series
UL Recognized CSA Certified VDE Approved*
**==> picture [143 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
3CFS1 15CS1<br>**----- End of picture text -----**<br>
## C € S Series eries
- Two function power entry module combining a DPST switch and an IEC 60320-1 inlet
- Snap–in or flange mounting
- Available with or without a shielded general purpose or medical grade filter
- Two element circuit provides enhanced EMI attenuation
- Reduce OEM wiring time with optional pre–connected line and switch terminals
## O Ordering rdering I Information nformation
## 10 C F S 1
- ~~L~~ Output Output S Styles tyles 1 – Spade terminals _(size varies)_
- M Mounting ounting S Styles tyles E – Flange Mount S – Snap–in
F Filter ilter T Type ype o or r T Terminal erminal O Option ption F – General purpose H – Medical B – No filter, includes Pre–connected terminals Omit if none C C S Series eries C Current urrent R Rating ating 1, 3, 6, 10 or 15A _(Filtered versions up to 10A)_
## S Specifications pecifications
Maximum leakage current each Line to Ground:
|F Models|F Models|H & Unfiltered|
|---|---|---|
|@ 120 VAC 60 Hz:|.25 mA|2A|
|@250 VAC 50 Hz:|.40 mA|5A|
|Hipot rating (one minute):|||
|Line to Ground:<br>Line to Line:||2250 VDC<br>1450 VDC|
|Rated Voltage:<br>Operating Frequency:||250 VAC<br>50/60 Hz|
|Rated Current:||1 to 15A*|
|Switch:||DPST|
|10,000 operations at 51A max. inrush|||
|.250 Terminal Push–on Force:<br>.188 Terminal Push–on Force:|18 lb. / 80N (max.)<br>15 lb. / 67N (max.)||
## A ~~Available~~ vailable P ~~Part~~ art N ~~Numbers~~ umbers
|ailable P<br>ilable P<br>lable P<br>able P<br>ble P<br>le P<br>e P<br>P<br>art N<br>rt N<br>t N<br>N<br>umbers<br>mbers<br>bers<br>ers<br>rs<br>s<br>~~Available Part Numbers~~|ailable P<br>ilable P<br>lable P<br>able P<br>ble P<br>le P<br>e P<br>P<br>art N<br>rt N<br>t N<br>N<br>umbers<br>mbers<br>bers<br>ers<br>rs<br>s<br>~~Available Part Numbers~~|
|---|---|
|Filtered Versions||
|1CHE1|1CFE1|
|3CHE1|3CFE1|
|6CHE1|6CFE1|
|10CHE1|10CFE1|
|1CHS1|1CFS1|
|3CHS1|3CFS1|
|6CHS1|6CFS1|
|10CHS1|10CFS1|
|Non–filtered Versions||
|Standard Terminals|Pre-connected Terminals|
|10CS1<br>10CE1<br>15CS1|10CBS1<br>10CBE1<br>15CBS1|
|15CE1|15CBE1|
- _*15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC_
130
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Power Entry Module with Switch** _(continued)_
## C Series
## E Electrical lectrical Sectrical Sctrical Strical Srical Sical Scal Sal Sl S S Schematics chematicshematicsematicsmaticsaticsticsicscss
**==> picture [461 x 561] intentionally omitted <==**
**----- Start of picture text -----**<br>
E Electrical lectrical Sectrical Sctrical Strical Srical Sical Scal Sal Sl S S Schematics chematicshematicsematicsmaticsaticsticsicscss CE, CBE<br>A<br>F Models B .210 5.34 F<br>LINE LOAD Max.<br>C<br>“ 1 C ft fh4 ©/ =©<br>——as<br>H Models <br>LINE LOAD <br><br> <br> <br> <br>CFS, CHS<br>B Models<br>Power On/Off C<br>L L<br>Note 1 Note 2<br>G G<br>1 o > —<br>Note 1 Note 2 A .210 B<br>N Je ee N 5.34 U<br>Max.<br><br> <br> <br> <br>C Case ase S Styles tyles<br>CS, CBS CFE, CHE<br>B .210 5.34 [Max.] A<br>r Ex] C<br>C<br>.210<br>F 5.34 Max. B<br>A<br> <br> <br> <br> <br> <br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
131
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Power Entry Module with Switch** _(continued)_
## C Series
## C Case ase S Styles tyles _(continued)_
## C Case ase D Dimensions imensions
## CBS, CBE Pre-Connected Terminals
**==> picture [205 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
CBS, CBE Side View CBE Rear View CBS Rear View<br>**----- End of picture text -----**<br>
|Part No.|A<br>|B<br>|C<br>|D<br><br>__|E<br><br>__|F<br><br>__|
|---|---|---|---|---|---|---|
|CS, CBS|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__||
|CE, CBE|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|CFS, CHS|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__||
|CFE, CHE|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
__ __
## R Recommended ecommended P Panel anel C Cutout utout
A Accessories ccessories G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord
**==> picture [163 x 126] intentionally omitted <==**
**----- Start of picture text -----**<br>
.06<br>R max<br>D 1.52<br>-— n e e<br>E<br>oO ron<br>F<br>**----- End of picture text -----**<br>
- __ __
132
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Power Entry Module with Switch** _(continued)_
## C Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
## 1CF 3CF 6CF
## 10CF
**==> picture [492 x 250] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db db db<br>100 100 100 100<br>90 90 90 90<br>80 |Oo To 80 A 80 | 80 ||<br>70 0 70 a 70 | 70 C CIEet Ceri 1<br>60 As 60 a 60 | 60 |<br>50 F amelll 50 oe 50 | em 50 econ J<br>40 Co LT | 40 [To 40 [TTI 40 a<br>30 | 30 oe CE 30 = WE 30 Ie<br>2010 IE| ie 2010 — CO CCIEi 2010 = |CCE 2010 [errmerrii<br>0 0.1 1 10 30 CCoi Coir 0 0.1 1 10 30 [IEE 0 0.1 1 10 30 LConi Toir F] 0 0.1 1 10 30 A Ci I<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>1CH 3CH 6CH 10CH<br>db db db db<br>10090 CO on 10090 COL on 10090 COL Lo oi 10090 COO<br>80 COC 80 80 80 Con co<br>70 COC CIE Cee 70 ST 70 CO CCIE Cee 70 COE IC<br>60 COOCCIE Cia 60 CCIE COI I 60 CO CCIE Cee 60 COE IC<br>50 0 50 LO CI 50 CO CCIE Cee 50 COE CIE Co<br>40 40 40 40<br>30 COILDP a,S e er 30 Pt Pail { 30 COOCO FECIE CI 30 CO|<br>20 CAINS 20 At 20 CAI A 20 Et<br>10 10 10 10<br>0 0.01 0.1 1 10 30 LOLI COCreIE 7] 0 0.01 0.1 1 10 30 Pr anill|HT | nt | 0 0.01 0.1 1 10 30 mapa 0 __— 0.01 0.1 1 10 30 TTet<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>Common Mode / Asymmetrical (L-G)<br>Differential Mode / Symmetrical (L-L)<br>**----- End of picture text -----**<br>
## 1CH
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|** **|||** **|** **|** **||||** **|||** **|** **|** **|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****||****|****|****|****|****|****|****|****|
|** **|||||||||** **||||||||
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
|** **|||||||||** **||||||||
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
133
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Compact 1U Height Switched Power Entry Module**
## CU Series
UL Recognized CSA Certified VDE Approved*
**==> picture [123 x 28] intentionally omitted <==**
**----- Start of picture text -----**<br>
6CUFS1<br>15CUE1<br>**----- End of picture text -----**<br>
## C CU U S Series eries
- Designed for popular 1U (1 ¾”) height rack mounted equipment
- Two function power entry module combining a SPST switch and an IEC 60320-1 inlet
- Snap–in, flange and flush mounting
- Reduce OEM wiring time with optional pre–connected line and switch terminals
## O Ordering rdering I Information nformation
## 15 CU 10 B S 1
> O Output utput S Styles tyles 1 – .187 [ _4.8_ ] spade terminals
> M Mounting ounting S Styles tyles E – Flange Mount _(Horizontal)_ F – Flush Mount _(Filtered only)_ S – Snap–in F Filter ilter T Type ype o or r T Terminal erminal O Option ption F – General purpose B – No filter, includes pre–connected terminals Omit if none S Side ide S Snap nap ~~-i –~~ i n n O Option ption _Non-filtered versions only_ 10 – Side snaps _1.0mm max. panel_ 15 – Side snaps _1.5mm max. panel_ Omit for none or
## S Specifications pecifications
Maximum leakage current each Line to Ground:
||Filtered|Unfiltered|
|---|---|---|
|@ 120 VAC 60 Hz:|.25 mA|2A|
|@250 VAC 50 Hz:|.40 mA|5A|
|Hipot rating (one minute):|||
|Line to Ground:<br>Line to Line:||2250 VDC<br>1450 VDC|
|Operating Voltage:<br>Operating Frequency:||120/250 VAC<br>50/60 Hz|
|Rated Current:||1 to 15A*|
|Switch:|50A inrush capable SPST||
|Terminal Push–on Force:|15 lb. / 67N (max.)||
## A Available vailable P Part art N Numbers umbers
|ailable P<br>ilable P<br>lable P<br>able P<br>ble P<br>le P<br>e P<br>P<br>art N<br>rt N<br>t N<br>N<br>umbers<br>mbers<br>bers<br>ers<br>rs<br>s<br>Available Part Numbers|ailable P<br>ilable P<br>lable P<br>able P<br>ble P<br>le P<br>e P<br>P<br>art N<br>rt N<br>t N<br>N<br>umbers<br>mbers<br>bers<br>ers<br>rs<br>s<br>Available Part Numbers|
|---|---|
|Filtered Versions<br>1CUFE1<br>1CUFF1<br>1CUFS1||
|3CUFE1<br>6CUFE1<br>10CUFE1<br>15CUFE1|3CUFF1<br>3CUFS1<br>6CUFF1<br>6CUFS1<br>10CUFF1<br>10CUFS1<br>15CUFF1<br>15CUFS1|
|Non–filtered Versions||
|Standard Terminals<br>Pre-connected Terminals||
|15CUE1|15CUBE1|
|15CUS1|15CUBS1|
|15CU10S1<br>15CU10BS1||
|15CU15S1<br>15CU15BS1||
standard configuration
> C CU U S Series eries C Current urrent R Rating ating 1, 3, 6, 10 or 15A
- _*15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC_
134
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Compact 1U Height Switched Power Entry Module** _(continued)_
**==> picture [465 x 594] intentionally omitted <==**
**----- Start of picture text -----**<br>
CU Series<br>Electrical Schematic CUFS1<br>LINE LOAD<br>C<br>Case S EE tyles | EO. A B<br>CUFE1<br><br> <br> <br> <br> <br>C<br>CUE1<br>F B<br>‘=<br>A C<br><br> <br>R=) app<br> <br> F B<br> <br> <br>e A an<br>CUFF1 <br><br> <br><br> <br>C <br> <br>CUS1<br>B<br>aL F<br>A<br>C<br>ae a (h<br>A B<br>(| oR ) Ee<br> <br><br> <br> <br> <br>**----- End of picture text -----**<br>
__ __ __ __ __
135
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help**
**corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Compact 1U Height Switched Power Entry Module** _(continued)_
## CU Series
## C Case ase S Styles tyles _(continued)_
CU10S1 & CU15S1 ~~Todi~~ | C ~~(e~~ B A B ~~a~~ __ __ __ __
## CUBE1 Pre-Connected Terminals
## C Case ase D Dimensions imensions
|Part No.|A<br>|B<br>|C<br>|D<br><br>__|E<br><br>__|F<br><br>__|
|---|---|---|---|---|---|---|
|CUFE1<br>****<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>__<br>~~re~~|||||||
|CUFF1|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|CUFS1|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****|
|CUE1,|****|****|****|****|****|****|
|CUBE1|__|__|__|__|__|__|
|CUS1,|****|****|****|****|****|****|
|CUBS1|__|__|__|__|__||
|10CUS1,|****|****|****|****|****|****|
|10CUBS1|__|__|__|__|__||
|15CUS1,|****|****|****|****|****|****|
|15CUBS1|__|__|__|__|__||
**==> picture [67 x 83] intentionally omitted <==**
**----- Start of picture text -----**<br>
|, @ | °<br>**----- End of picture text -----**<br>
## CUBS1 Pre-Connected Terminals
## CU10BS1 & CU15BS1 Pre-Connected Terminals ~~ize~~
**==> picture [227 x 225] intentionally omitted <==**
**----- Start of picture text -----**<br>
Recommended Panel Cutout<br>F<br>Recommended Panel Cutout<br>R. Max D<br>= =<br>E<br>© |. ©<br> <br> <br> <br> On <br> <br> <br> <br>**----- End of picture text -----**<br>
Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord GA400 AccessoriesCED)
136
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Compact 1U Height Switched Power Entry Module** _(continued)_
## CU Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [493 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
1CUF 3CUF 6CUF 10CUF<br>db db db db<br>10090 COO on- o 10090 COL Cn oT 10090 COL Lo Co 10090 COO<br>80 COO CCIE Cee 80 80 COI OIE CO 80 COICon Oo<br>70 COI I CT 70 70 COE CIE Ce | 70 CCIE Cor 1<br>60 COI 60 60 60 OIE Cee<br>50 CO IE Cr 50 )\ 50 COE CIE Coe 2 50 CO CIE Co |<br>40 COI a 40 oF 40 COICO aA 40 CC COI<br>30 CT AAI 30 tefo HT 30 COTCOI Cea 30 OooCI y<br>20 20 20 20<br>100 aaPl 100 =Seil COMIetlCOI a 100 Pail 100 ae<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## 15CUF
**==> picture [114 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db<br>10090 COO oI-T<br>608070 COCCICOOCOO CIECIE CeeCee<br>40503020100 CO0COTOCOIACIEri|onaTI [err] CTTeeoii 1Ci||<br>0.01 0.1 1 10 30<br>Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|** **|||** **|** **|** **||||** **|||** **|** **|** **|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****||****|****|****|****|****|****|****|****|
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
137
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Accessory Outlet Filter**
## EBF Series
UL Recognized CSA Certified VDE Approved
## EBF SF S Seriesriesiesess EBF BF SF S Seriesriesiesess Series eriesriesiesess
## EBF SF S Seriesriesiesess
- Accessory IEC 60320-1 C13 filtered outlet
- Allows connection of accessories while filtering noise between a system and the accessory
- Enhanced performance across the frequency range
- Grounded connection
- Suitable for international usage
## O Ordering rdering I Information nformation
3 EBF 1 ~~L~~ O Output utput Styles Styles 1 – .250 [ _6.3_ ] spade terminals 4 – Wire leads _(bottom)_
E EBF BF S Series eries C Current urrent R Rating ating 1, 3, 6, or 10A
**==> picture [174 x 86] intentionally omitted <==**
**----- Start of picture text -----**<br>
EBF1<br>3 ¢<br>EBF4<br>**----- End of picture text -----**<br>
## S Specifications pecifications
|S<br>pecifications<br>ecifications<br>cifications<br>ifications<br>fications<br>cations<br>ations<br>tions<br>ions<br>ons<br>ns<br>s<br>Specifications||
|---|---|
|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:|
|@ 120 VAC 60 Hz:|.25 mA|
|@250 VAC 50 Hz:|.50 mA|
|Hipot rating (one minute):||
|Line to Ground:|2250 VDC|
|Line to Line:|1450 VDC|
|Rated Voltage (max.):|250 VAC|
|Operating Frequency:|50/60 Hz|
|Rated Current:|1 to 10A|
|Operating Ambient Temperature Range||
|(at rated current Ir):|-10°C to +40°C|
|In an ambient temperature (Ta) higher than +40°C||
|the maximum operating current (Io) is calculated as|the maximum operating current (Io) is calculated as<br>follows: Io = Ir ~~~~(85-Ta)/45|
## E Electrical lectrical S Schematic chematic
**==> picture [187 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
ACCESSORY<br>LINE OUTLET<br>**----- End of picture text -----**<br>
## A Available vailable P Part art N Numbers umbers
|1EBF1|1EBF4|
|---|---|
|3EBF1|3EBF4|
|6EBF1|6EBF4|
|10EBF1|10EBF4|
138
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Accessory Outlet Filter** _(continued)_
## EBF Series
## C Case ase S Styles tyles
## C Case ase D Dimensions imensions
## EBF1
**==> picture [231 x 74] intentionally omitted <==**
**----- Start of picture text -----**<br>
A B C D E<br>Part No. <br> <br> <br>EBF1<br> <br> <br>EBF4<br> <br>**----- End of picture text -----**<br>
**==> picture [468 x 349] intentionally omitted <==**
**----- Start of picture text -----**<br>
C <br>EBF1<br> <br>D <br>E = A B EBF4<br> <br><br> <br><br> <br> <br> <br>EBF4 Recommended Panel Cutout<br>E<br>A B<br>D<br>B\ S C fo A———l oc 1.01<br>25.7<br>.14 Dia.<br>1.40 3.6<br>35.6<br>Hl bo gee a<br>1.575 ± .004<br>a 40.0 ± 0.1 .20 R Typ.<br>5.1<br>©<br><br>©<br> <br>|<br><br> <br><br> <br> <br>**----- End of picture text -----**<br>
139
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Accessory Outlet Filter** _(continued)_
## EBF Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
## 1EBF 3EBF
## 6EBF 10EBF
**==> picture [494 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db db db<br>100 100 100 100<br>90 A 90 A 90 a 90 |<br>8070 A 8070 a 8070 a 8070 |<br>60 a |_| 60 Lt ET Tt _| 60 0 60 |<br>50 Ss 50 a P— 50 iil ue ~ 50 aie<br>40 atl 2 40 ee ae 40 LL 40 en<br>30 ot | 30 Pall 30 aa 30 Lr]<br>20 |_| a 20 — | | 20 a 20 |_| Lee<br>10 Ui TE 10 10 10 iz<br>0 0 0 0<br>0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|** **|||** **|** **|** **||||** **|||** **|** **|** **|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****||****|****|****|****|****|****|****|****|
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
||||||||||||||||||
140
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **High Performance EMI Power Inlet Filter**
## EC Series ®
UL Recognized CSA Certified VDE Approved
**==> picture [198 x 89] intentionally omitted <==**
**----- Start of picture text -----**<br>
EC8 /<br>/<br>EC2<br>EC4<br>EC1<br>**----- End of picture text -----**<br>
## E EC C S Series eries
- Three element differential mode circuit provides the highest attenuation of any available standard inlet filter
- High common mode inductance
- High differential mode capacitance
- Effective attenuation of Line to Ground and Line to Line noise across the frequency range
- Performance and application similar to the ED series but with higher differential mode performance
- Includes several termination options
## O Ordering rdering I Information nformation
3 EC 1 Output Styles L_ Output Styles 1 – .250 [ _6.3_ ] spade terminals _(back)_ 2 – .250 [ _6.3_ ] spade terminals _(bottom)_ 4 – Wire leads _(bottom)_ 8 – Wire leads _(back)_ E EC C S Series eries
## S Specifications pecifications
|S<br>pecifications<br>ecifications<br>cifications<br>ifications<br>fications<br>cations<br>ations<br>tions<br>ions<br>ons<br>ns<br>s<br>Specifications||
|---|---|
|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:|
|@ 120 VAC 60 Hz:|.25 mA|
|@250 VAC 50 Hz:|.50 mA|
|Hipot rating (one minute):||
|Line to Ground:<br>Line to Line:|2250 VDC<br>1450 VDC|
|Rated Voltage (max.):|250 VAC|
|Operating Frequency:|50/60 Hz|
|Rated Current:|1 to 10A|
|Operating Ambient Temperature Range<br>(at rated current Ir):<br>-10°C to +40°C||
|In an ambient temperature (Ta) higher than +40°C||
|the maximum operating current (Io) is calculated as|the maximum operating current (Io) is calculated as<br>follows: Io = Ir ~~~~(85-Ta)/45|
## E Electrical lectrical Schematic Schematic
**==> picture [211 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>**----- End of picture text -----**<br>
C Current urrent R Rating ating 1, 3, 6, or 10A
## A Available vailable P Part art N Numbers umbers
|1EC1<br>3EC1<br>6EC1<br>10EC1|1EC2<br>3EC2<br>6EC2|1EC4<br>3EC4<br>6EC4|1EC8<br>3EC8<br>6EC8|
|---|---|---|---|
141
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **High Performance EMI Power Inlet Filter** _(continued)_
## EC Series
**==> picture [477 x 587] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles C Case ase D Dimensions imensions<br>EC1<br>Part A B C D E<br>C No. <br> <br>EC1<br>(R D A T @ep| B <br>E<br> <br>EC2<br> <br> <br>EC2 EC4<br> <br> <br>C EC8<br> <br> .65 Max.<br>16.5<br>@ h e<br>D<br>E A B<br> —_a) ED R Recommended ecommended Pcommended Pommended Pmmended Pmended Pended Pnded Pded Ped Pd P P Panel anel Cnel Cel Cl C C Cutouts utoutstoutsoutsutstss<br> <br>Front Mount Back Mount<br> <br> <br>.820 .900<br>20.8 22.9<br>EC4<br>.140<br>1.200 3.56 1.200<br>30.48 30.48<br>an) C ICECEE ~~ 40.01 1.575 x.R:R: .062 R.Typ. ( | 40.01 1.575 CseReRR<br>1.58 Typ.<br>Tolerances ± .005 [ 0.13 ] unless otherwise noted<br>D<br> <br>— E =) (a A a <br>B<br>F<br>A Accessories ccessories<br>i G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord<br>F<br>EC8<br>ET<br>F<br>Blue<br>aa =" : SezASS<br>Green/Yellow<br>D E Brown B FA601: Insulating Shroud<br>° = = EE© F FA6O1 _ 10.5 .413.271 Dia.Dia.<br>6.9<br>A<br>.118<br>3.0<br>1.39<br>C 35.4<br>ff<br>= JF 1.17 .767<br> 29.7 19.5<br> <br> <br>Brown Blue<br>Green/Yellow<br>**----- End of picture text -----**<br>
**==> picture [233 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
Part A B C D E F<br>No. <br>EC1 <br> <br>EC2 <br> <br> <br>EC4<br> <br> <br>EC8<br> <br>**----- End of picture text -----**<br>
**==> picture [240 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
R Recommended ecommended Pcommended Pommended Pmmended Pmended Pended Pnded Pded Ped Pd P P Panel anel Cnel Cel Cl C C Cutouts utoutstoutsoutsutstss<br>Front Mount Back Mount<br>.820 .900<br>20.8 22.9<br>1.200 3.56 .140 1.200 3.56 .140 <br>30.48 30.48<br>~~ 1.575 | 1.575<br>ICECEE 40.01 x.R:R: .062 1.58 R.Typ. ( 40.01 CseReRR 5.94 .234 R.Typ.<br>Tolerances ± .005 [ 0.13 ] unless otherwise noted<br> <br> <br>**----- End of picture text -----**<br>
142
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **High Performance EMI Power Inlet Filter** _(continued)_
## EC Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [493 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
1EC 3EC 6EC 10EC<br>db db db<br>10090 | 10090 | a 10090 |<br>8070 EECom I 8070 |ll [7 [Ce 8070 |||<br>60 0AM 60 [IEA TTS ead [CIE 7S 60 |<br>4050 eerilyrn 4050 a) a COM [ares] _ 4050 [CEIPAC She<br>30 LOA tiCor 30 er”Pe ml [COZee 30 [CIE|) 7 een]<br>2010 eeCIE 2010 CCA ie er ie 2010 ery ii|<br>0 0.1 1 10 30 COCO CCIE 0 0.1 1 10 30 LOaCi CCT alCOM 0 0.1 1 10 30 ||<br>Frequency in MHz Frequency in MHz Frequency in MHz<br>db<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>0.1 1 10 30<br>Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
|** **|||** **|** **|** **|||** **|||** **|** **|** **|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****||****|****|****|****|****|****|****|****|
|||||||||****||||||||
|||||||||||||||||
|||||||||||||||||
|||||||||||||||||
|||||||||||||||||
|||||||||****||||||||
|||||||||||||||||
|||||||||||||||||
|||||||||||||||||
143
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Medium Performance Compact EMI Power Inlet Filter**
## ED Series
UL Recognized CSA Certified VDE Approved*
## E ED D S Series eries
- Two element circuit provides medium attenuation
- Available with an internal ground-circuit inductor (C versions) to isolate equipment chassis from power line ground at radio frequencies
- Versions up to 15A*
- Similar to EEJ Series with alternative termination options
- See the EC Series for better differential mode performance
## O Ordering rdering I Information nformation
3 ED 1 C Gr Pe ound Ci NE rcuit In NOT ductor Omit if none - O G utpu d t Circuit Styles Induct 1 – .250 [ _6.3_ ] spade terminals _(back)_ 2 – .250 [ _6.3_ ] spade terminals — (bottom)_ 4 – Wire leads _(bottom)_ 8 – Wire leads _(back)_
**==> picture [220 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
ED2<br>ED1 / ED1C<br>EC4 / ED4C<br>EC8 / ED8C<br>é&<br>**----- End of picture text -----**<br>
## S Specifications pecifications
|S<br>pecifications<br>ecifications<br>cifications<br>ifications<br>fications<br>cations<br>ations<br>tions<br>ions<br>ons<br>ns<br>s<br>Specifications||
|---|---|
|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:|
|@ 120 VAC 60 Hz:<br>@250 VAC 50 Hz:|.22 mA<br>.38 mA|
|Hipot rating (one minute):||
|Line to Ground:<br>Line to Line:|2250 VDC<br>1450 VDC|
|Rated Voltage (max.):|250 VAC|
|Operating Frequency:|50/60 Hz|
|Rated Current:|1 to 15A*|
|Operating Ambient Temperature Range||
|(at rated current Ir):|-10°C to +40°C|
|In an ambient temperature (Ta) higher than +40°C<br>the maximum operating current (Io) is calculated as<br>follows: Io = Ir ~~~~(85-Ta)/45||
|A<br>v<br>a<br>i<br>l<br>a<br>b<br>l<br>e<br>P<br>a<br>r<br>t<br>N<br>u<br>m<br>b<br>e<br>r<br>s<br>1ED1<br>1ED2<br>1ED4<br>3ED1<br>3ED2<br>3ED4<br>6ED1<br>6ED2<br>6ED4<br>10ED1<br>15ED1<br>Available Part Numbers<br>~~ff ~~|A<br>v<br>a<br>i<br>l<br>a<br>b<br>l<br>e<br>P<br>a<br>r<br>t<br>N<br>u<br>m<br>b<br>e<br>r<br>s<br>1ED1<br>1ED2<br>1ED4<br>3ED1<br>3ED2<br>3ED4<br>6ED1<br>6ED2<br>6ED4<br>10ED1<br>15ED1<br>Available Part Numbers<br>~~ff ~~|1ED8<br>3ED8<br>6ED8<br>15ED8<br> ~~fe~~|1ED8<br>3ED8<br>6ED8<br>15ED8<br> ~~fe~~|
|---|---|---|---|
||Ground Circuit Inductor Versions|||
||6ED1C<br>6ED4C||6ED8C|
||10ED1C|||
ED Series
> C Current urrent R Rating ating 1, 3, 6, 10 or 15A
## E Electrical lectrical S Schematic chematic
LINE LOAD 1
_*15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC Note 1: C versions only_
144
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Medium Performance Compact EMI Power Inlet Filter** _(continued)_
## ED Series
## C Case ase S Styles tyles
**==> picture [493 x 528] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|ED1 & ED1C|ED8 & ED8C|
|F|
|C|Blue|
|Green/Yellow|
|D|E|B|
|Brown|
|D|A|B|
|E|F|
|[64|
|a|=)||||po|[|]|
|A|
||
|||||||
||
|||C|
|||||||
|||||||=|=|
||
|||||||
||
|||
|ED2| ||| |
|Case Dimensions|
|C|
|A|B|C|D|E|F|
|Part No.||
|.65|Max.|||||||
|16.5|
|D|1ED1, 3ED1,|||||||
|iBeec|E|c|oZ|A|o|B|6ED1|ee|Case Dimensions|||||-||
||1ED2, 3ED2,|||||||
|||||||6ED2||||||
||
|||1ED4, 3ED4,|||||||
|||||||6ED4|||||||
|||||||
|1ED8, 3ED8,|||||||
|6ED8|||||||
|ED4 & ED4C|
|6ED1C|||||||
||||||
|C|||||||
|6ED4C|
|CCE|||||||||
|D|||||||
|6ED8C|
|ral|E|Lo|A|||||||
|B|
|F|10ED1 /1C,|||||||
|15ED1||||||
|15ED8|||||||
||||||
|F|
|z|
||
|||||||
||
|||
| ||| |
**----- End of picture text -----**<br>
145
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Medium Performance Compact EMI Power Inlet Filter** _(continued)_
## ED Series
## R Recommended ecommended P Panel anel C Cutouts utouts
## A Accessories ccessories
**==> picture [241 x 88] intentionally omitted <==**
**----- Start of picture text -----**<br>
Front Mount Back Mount<br>.820 .900<br>20.8 22.9<br>. i<br>1.200 i 3.56 .140 1.200 RG 3.56 .140 <br>30.48 30.48<br>1.575 1.575<br>i 40.01 E .062 : 1.58 R.Typ. Ee 40.01 5.94 .234 ; R.Typ.<br>Tolerances ± .005 [ 0.13 ] unless otherwise noted<br>**----- End of picture text -----**<br>
> G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord
**==> picture [211 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
F FA6O1 A601: Insulating Shroud<br>.413 Dia.<br>10.5<br>.271 Dia.<br>6.9<br>u -—<br>.118<br>3.0<br>1.39<br>35.4<br>i nn oe<br>1.17 .767<br>—-_| 29.7 —{— 19.5<br>**----- End of picture text -----**<br>
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [148 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
1ED 3ED<br>**----- End of picture text -----**<br>
## 6ED 6ED1C
**==> picture [492 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db db db<br>100 100 100 100<br>90 CoCo Coo 90 COC Coo 90 Coo Ct _] 90 a<br>80 80 80 80<br>70 HS 70 Er 70 oo 70 oe<br>406050 bet ZT |oS 406050 ! i| 406050 a[Con 406050 aO_o<br>30 a 30 HH et ean 30 ee 30 OIC<br>WAZA th Cll iI [ie | 6<br>20 20 20 20<br>10 10 10 10<br>0 atl CHI 0 | i | [CT 0 0 |<br>0.1 1 10 100 0.1 1 10 100 0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## 10ED1 & 10ED1C 15ED
**==> picture [241 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
db<br>10090db 1009080 CoCOI CIooonCIF<br>80 70<br>70 || 60 ne ,<br>60 EEE HH 50 a<br>50 | z 40 COUN FTI FA<br>40 30<br>30 20<br>20 Sen asia 10 te caciee<br>10 i 0 eH<br>0 0.1 1 10 30 0.01 0.1 1 10 30Frequency in MHz<br>i<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
146
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Medium Performance Compact EMI Power Inlet Filter** _(continued)_
## ED Series
## P Performance erformance D Data ata _(continued)_
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
|** **|||** **|** **|** **|||** **|||** **|** **|** **|** **||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****||****|****|****||****|****|****|****|
|****||||||||****||||||||
|||||||||||||||||
|||||||||||||||||
|||||||||||||||||
|||||||||||||||||
|||||||||||||||||
|****||||||||****||||||||
|||||||||||||||||
|||||||||||||||||
|****||||||||****||||||||
|||||||||||||||||
147
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Cost-effective EMI Power Inlet Filter**
## EEA & EEB Series
Including the EAS/EBS and EAH/EBH Models
## UL Recognized CSA Certified VDE Approved
**==> picture [122 x 28] intentionally omitted <==**
**----- Start of picture text -----**<br>
EEA1 / EEB1<br>EEA2 / EEB2<br>**----- End of picture text -----**<br>
_EEAP / EEBP_
## E EEA EA S Series eries
- Compact single stage EMI filter with IEC 60320-1 C14 inlet
- Two element circuit provides basic attenuation
- Same performance as the EF Series
- Available in three terminal configurations
- Supersedes EF Series
## E EEB EB SB S S Series eriesriesiesess
## E EEB EB SB S S Series eriesriesiesess
- Compact EMI filter with IEC 60320-1 C14 inlet
- Two element circuit provides extended attenuation
- Extended differential mode performance
- Available in three terminal configurations
## S Specifications pecifications
|S<br>pecifications<br>ecifications<br>cifications<br>ifications<br>fications<br>cations<br>ations<br>tions<br>ions<br>ons<br>ns<br>s<br>Specifications|||
|---|---|---|
|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:||
||EEA/EEB||
||EAS/EBS|EAH/EBH|
|@ 120 VAC 60 Hz:|.22 mA|2A|
|@ 250 VAC 50 Hz:|.38 mA|5A|
|Hipot rating (one minute):|||
|Line to Ground:||2250 VDC|
|Line to Line:||1450 VDC|
|Rated Voltage (max.):||250 VAC|
|Operating Frequency:||50/60 Hz|
|Rated Current:||1 to 10A|
|Operating Ambient Temperature Range|||
|(at rated current Ir):||-10°C to +40°C|
|In an ambient temperature (Ta) higher than +40°C|||
|the maximum operating current (Io) is calculated as|the maximum operating current (Io) is calculated as<br>follows: Io|the maximum operating current (Io) is calculated as<br> = Ir ~~~~(85-Ta)/45|
## EAS & EBS Models
- Same performance as EEA and EEB Series
- Snap–in mounting
## E Electrical lectrical S Schematic chematic
- Spade terminals
## EAH & EBH Models
- Same size as EEA and EEB
- Minimal leakage current suitable for medical applications
- Flange mounted
- Spade terminals
**==> picture [210 x 55] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>© 1<br>1<br>~ L C3 i + O<br>**----- End of picture text -----**<br>
_Note 1: Not present in EAH / EBH versions_
148
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Cost-effective EMI Power Inlet Filter** _(continued)_
## EEA & EEB Series
## O Ordering rdering I Information nformation
3 EEB 1 Loo O ueput utput Styles Styles 1 – .250 [ _6.3_ ] spade terminals _(back)_ 2 – .250 [ _6.3_ ] spade terminals _(bottom)_ P – PC board pins
S Series eries
EEA – Basic Inlet Filter
EAS – Snap–in EEA Filter EAH – Medical EEA Filter EEB – Extended EMI Performance EBS – Snap-in EEB Filter EBH – Medical EEB Filter
C Current urrent R Rating ating 1, 3, 6, or 10A
## A Accessories ccessories
## A Available vailable P Part art N Numbers umbers
|EEA Models<br>1EEA1|EEB Models<br>1EEB1|
|---|---|
|1EEA1<br>1EEA2<br>1EEAP<br>3EEA1<br>3EEA2<br>3EEAP<br>6EEA1<br>6EEA2<br>6EEAP<br>10EEA1<br>10EEA2<br>10EEAP|1EEB1<br>1EEB2<br>1EEBP<br>3EEB1<br>3EEB2<br>3EEBP<br>6EEB1<br>6EEB2<br>6EEBP<br>10EEB1<br>10EEB2<br>10EEBP|
|EAS Models|EBS Models|
|1EAS1<br>3EAS1<br>6EAS1<br>10EAS1|1EBS1<br>3EBS1<br>6EBS1<br>10EBS1|
|EAH Models|EBH Models|
|1EAH1<br>3EAH1<br>6EAH1<br>10EAH1|1EBH1<br>3EBH1<br>6EBH1<br>10EBH1|
> G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord
**==> picture [111 x 29] intentionally omitted <==**
**----- Start of picture text -----**<br>
FA601: Insulating Shroud<br>FA6O1<br>**----- End of picture text -----**<br>
**==> picture [106 x 83] intentionally omitted <==**
**----- Start of picture text -----**<br>
.413 Dia.<br>10.5<br>.271 Dia.<br>6.9<br>.118<br>3.0<br>1.39<br>35.4<br>os 29.7 1.17 |— .767 19.5<br>**----- End of picture text -----**<br>
**==> picture [36 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
EAS / EBS<br>**----- End of picture text -----**<br>
149
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Cost-effective EMI Power Inlet Filter** _(continued)_
## EEA & EEB Series
## C Case ase S Styles tyles EEA1, EEB1, EAH1 & EBH1
## C Case ase D Dimensions imensions
**==> picture [241 x 125] intentionally omitted <==**
**----- Start of picture text -----**<br>
A B C D E<br>Part No. <br> <br>EEA1, EEB1, <br>EAH1, EBH1, EBH1 EBH1 <br> <br>EEA2, EEB2<br> <br>re<br> <br>EEAP, EEBP<br> <br> <br>EAS1, EBS1<br> <br>**----- End of picture text -----**<br>
**==> picture [494 x 539] intentionally omitted <==**
**----- Start of picture text -----**<br>
EEA1, EEB1, <br>C EAH1, EBH1, EBH1 EBH1 <br> <br>D EEA2, EEB2<br>E A B <br>Ea! ale re<br> <br> EEAP, EEBP<br> <br> <br> EAS1, EBS1<br> <br> <br>EEA2 & EEB2 R Recommended ecommended P Panel anel C Cutouts utouts<br>EEA, EEB, EAH, EBH<br>C Front Mount Back Mount<br>.50 12.7 [Max][.] 20.8 .820 .900 22.9<br>| Oo | | — [0] — dg —<br>C} D LL A B Oe 1.14* 3.56 .140 w 1.200 oe 3.56 .140 <br>E 28.96* 30.48<br>1.575 1.575<br> 40.01 .12 R. 40.01 .234 R.<br> *± 0.02 [ 0.51 ] 3.05 Typ. 5.94 Typ.<br> Tolerances ± .005 [ 0.13 ] unless otherwise noted<br> <br> <br> <br>EEAP & EEBP<br>EAS, EBS<br>G <br>C<br>13.68 .537 [Ref.] <br>Cpay D CT ± .010 13.995 0.551 9.652 A .380 Max. S| 20.70 .815 <br>E A B<br> -er T T I = R 0.188 [(4X) 4.78 ] oo<br> <br><br> <br> <br>P PC C B Board oard L Layout ayout<br>EAS1 & EBS1 0.075<br>∅<br>1.91<br>C Max. 20.5 .81 0.520<br>13.21<br>D<br>E A B<br>0.551<br> .685* 13.99<br> 17.40*<br> *±.015 [ 0.38 ]<br>**----- End of picture text -----**<br>
150
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Cost-effective EMI Power Inlet Filter** _(continued)_
## EEA & EEB Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## EEA, EAS Models
**==> picture [492 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
1A 3A 6A 10A<br>db db db db<br>1009080 eeee 1009080 eea ee 1009080 aa 1009080 eei<br>70 ee 70 ee 70 | ee 70 |<br>60 60 60 60<br>|| SN I. A. a<br>50 | | | N 50 i ee 50 | ee a 50 | a\<br>40 Pant ee all 40 a) 40 Pe 40 ee<br>30 rot VA 30 Pet el 30 ee ai 30 Lt rr iTa<br>20 LIA 20 bet VAT 20 Lert i TAT 20 el<br>10 Pe a 10 ee 10 ee 10 P|<br>0 err TET 1 0 Lert | | iil 1 0 at 0 ee<br>0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
**==> picture [142 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
1A 3A<br>**----- End of picture text -----**<br>
## EEB, EBS Models
**==> picture [13 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
1A<br>**----- End of picture text -----**<br>
## 3A
## 6A 10A
**==> picture [492 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db db db<br>100908070 Peeeee 100908070 aeliee 100908070 aliePe 100908070 eeeeelli<br>60 | 60 PTT AT 60 IAA 60 AA<br>50 —__——_——"" 1 50 ee 50 | eee 50 | Pe<br>40 ert AT 40 Pn) ell 40 LT Aa 40 LI<br>30 el | 30 err ALT 30 a) 30 ed line<br>20 Pe) al 20 err | A TT 20 pe le 20 a ill<br>10 | 10 eet 10 ee ee 10 Leer TTI TT<br>0 0.1 1 10 30 ee 00 ee 0 bet 0.1 1 10 30 TM TEE TJ 0 0.1 1 10 30 ce 0 0.1 1 10 30 Seti TTT TI<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## EAH Models
## 6A 10A
## 1A
## 3A
**==> picture [363 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db db<br>100908070 eeelel 100908070 eeeeel 100908070908070807070 alealeaa el<br>60 | | 60 ee 60 a le<br>50 ee 50 a ee 50 le<br>40 Pe ee 40 | | 40 el<br>30 ath) 30 30<br>20 LIA 20 To 20 ee<br>10 a 10 Paella 10 ett | ee ee<br>0 ee ael 0 e nl =elieel 0 ee elilele<br>0.1 1 10 30 0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
**==> picture [240 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db<br>1009080 eeeeel<br>100908070908070807070 alealeaa el 70 ael<br>60 a le 60 ee<br>50 le 50 ee<br>40 el 40 |<br>30 30 ee<br>20 ee 20 a a<br>10 ett | ee ee 10<br>0 ee elilele 0 PPenanneeeis<br>0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## EBH Models
**==> picture [13 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
1A<br>**----- End of picture text -----**<br>
**==> picture [16 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
3A<br>**----- End of picture text -----**<br>
**==> picture [240 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db<br>10060908070 eeeeeeee 10090608070 eeeeeeee<br>50 a ee 50 ee<br>40 Pet ie 40 | a<br>30 ee an. 30 ee ae,<br>20 a al 20 a el<br>100 callee 100 antl2 eeel<br>0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
**==> picture [240 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
6A 10A<br>db db<br>10090608070 aleeeee 10090608070 eeaale<br>50 le 50 el<br>40 a 40 a<br>30 Le 30 a al<br>20 P=. ae 20 |tt<br>100 eseleTT TT 100 eera TI aTT<br>0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
151
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Cost-effective EMI Power Inlet Filter** _(continued)_
## EEA & EEB Series
## P Performance erformance D Data ata _(continued)_
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|** **||||** **|** **|** **|** **||||** **|** **|||** **|** **|** **|** **||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****||****|****|****|****|****|****|****||****||****|****|****|****|****|****|****|
|** **|||||||||||** **|||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||** **|** **|||||
|||||||||||||****|****|****|****|****|****|****|****|
|** **|||||||||||** **|||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||** **|** **|||
||||||||||||||||****|****|****|****|****|
|** **|||||||||||** **|** **||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
||||||||||||||||** **|** **||||
|||||||||||||||****|****|****|****|****|****|
|** **|||||||||||** **|** **||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
152
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Cost-effective Medium Performance Power Inlet Filter**
## EEJ Series
Including the EJH/EJHS, EJM/EJMS and EJS Models
## UL Recognized CSA Certified VDE Approved*
**==> picture [152 x 58] intentionally omitted <==**
**----- Start of picture text -----**<br>
— 20EJH1 LDP<br>3EEJ1<br>20EEJ8<br>**----- End of picture text -----**<br>
## E EEJ EJ S Series eries
- Compact EMI filter with IEC 60320-1 C14 Inlet
- Enhanced two element circuit provides medium attenuation to 30MHz
- Compact and cost-effective design
- Supersedes most ED Series versions
- Includes 20A version with standard IEC 60320-1 C20 inlet
- Several termination styles
- Flanged mounting
## EJS Models
- Same performance as the EEJ Series
- Snap-in mounting
- Several termination styles
## S Specifications pecifications
|S<br>pecifications<br>ecifications<br>cifications<br>ifications<br>fications<br>cations<br>ations<br>tions<br>ions<br>ons<br>ns<br>s<br>Specifications||
|---|---|
|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:|
|EEJ/EJS<br>EJH<br>EJM<br>@ 120 VAC 60 Hz:<br>.22 mA<br>2A<br>.01 mA<br>@250 VAC 50 Hz:<br>.38 mA<br>5A<br>.017 mA||
|Hipot rating (one minute):<br>Line to Ground:|2250 VDC|
|Line to Line:|1450 VDC|
|Rated Voltage (max.):|250 VAC|
|Operating Frequency:|50/60 Hz|
|Rated Current:|1 to 20A*|
|Operating Ambient Temperature Range||
|(at rated current Ir):<br>-10°C to +40°C<br>In an ambient temperature (Ta) higher than +40°C<br>the maximum operating current (Io) is calculated as<br>follows: Io = Ir ~~~~(85-Ta)/45||
- Includes 20A version with standard IEC 60320-1 C20 inlet
## EJH & EJHS Models
- Minimal leakage current suitable for patientcontact medical applications
- Flanged mounting the same as the EEJ Series
- Also available in snap-in versions (EJHS)
- Two element circuit provides modest EMI attenuation above 1MHz
- Capacitive input (refer to the H Series for capacitive output)
- EJHS models feature snap-in mounting
## E Electrical lectrical S Schematic chematic
**==> picture [225 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD<br>© 1<br>1<br>3 2 C oe<br>Note 1: Not present in EJH versions<br>**----- End of picture text -----**<br>
## EJM & EJMS Models
- Low leakage current, suitable for most medical applications
- Improved EMI attenuation up to 200MHz
- Mechanically the same as the EEJ Series with flange or snap-in mounting
- _*15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC_
- _20A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 16A, 250VAC_
- EJMS models feature snap-in mounting
153
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Cost-effective Medium Performance Power Inlet Filter** _(continued)_
EEJ Series Including the EJH/EJHS, EJM/EJMS and EJS Models
## O Ordering rdering I Information nformation
## A Available vailable P Part art N Numbers umbers
**==> picture [361 x 571] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|EEJ Models|EJH Models|
|1EEJ1|1EJH1|
|1EEJ2|1EJH2|
|1EEJP|1EJHP|
|tylesyleslesess|
|1EEJ8|1EJH8|
|6.3|] spade terminals|
|3EEJ1|3EJH1|
|3EEJ2|3EJH2|
|6.3|] spade terminals|
|3EEJP|3EJHP|
|3EEJ8|3EJH8|
|6EEJ1|6EJH1|
|6EEJ2|6EJH2|
|6EEJP|6EJHP|
|6EEJ8|6EJH8|
|10EEJ1|10EJH1|
|10EEJ2|10EJH2|
|10EEJP|10EJHP|
|10EEJ8|10EJH8|
|15EEJ1|15EJH1|
|Medical Inlet Filter|
|15EEJ2|15EJH2|
|15EEJP|15EJHP|
|15EEJ8|15EJH8|
|Rating|atingtingingngg|
|20EEJ1|20EJH1|
|20EEJ8|20EJH8|
|EJS Models|EJHS Models|
|1EJS1|1EJHS1|
|1EJS8|1EJHS8|
|3EJS1|3EJHS1|
|3EJS8|3EJHS8|
|6EJS1|6EJHS1|
|6EJS8|6EJHS8|
|me|
|10EJS1|10EJHS1|
|10EJS8|10EJHS8|
|15EJS1|15EJHS1|
|15EJS8|15EJHS8|
|20EJS1|
|20EJS8|
|.413|Dia.|EJM Models|EJMS Models|
|10.5|
|.271|6.9|Dia.|1EJM1|1EJMS1|
|1EJM8|1EJMS8|
|u|f|/|
|.118|3EJM1|3EJMS1|
|t|3.0|f|\|ft|
|35.4|1.39|3EJM8|3EJMS8|
|6EJM1|6EJMS1|
|a|29.7|1.17|.767|19.5|6EJM8|6EJMS8|
|10EJM1|10EJMS1|
|10EJM8|10EJMS8|
|15EJM1|15EJMS1|
|15EJM8|15EJMS8|
**----- End of picture text -----**<br>
3 EEJ 1 Looutput Output Styles Stylesyleslesess 1 – .250 [ _6.3_ ] spade terminals _(back)_ 2 – .250 [ _6.3_ ] spade terminals _(bottom)_ P – PC board pins 8 – Wire leads
## S Series eries
EEJ – Enhanced EMI Inlet Filter EJS – EEJ in Snap-in Mounting EJH – Enhanced Medical Inlet Filter EJHS – EJH in Snap–in Mounting EJM – Extended Performance Medical Inlet Filter EJMS – EJM in Snap-in Mounting C Current urrent R Rating atingtingingngg 1, 3, 6, 10, 15 or 20A
## A Accessories ccessories
**==> picture [224 x 100] intentionally omitted <==**
**----- Start of picture text -----**<br>
G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord<br>me<br>(Ces<br>F FA601 A601: Insulating Shroud<br>**----- End of picture text -----**<br>
154
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Cost-effective Medium Performance Power Inlet Filter** _(continued)_
EEJ Series Including the EJH/EJHS, EJM/EJMS and EJS Models
**==> picture [483 x 589] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles<br>EEJ1, EJH1 & EJM1 (1-15A) EEJ8, EJH8 & EJM8 (1-15A)<br>Blue<br>C<br>Green/Yellow<br>D E B<br>Brown<br>D B<br>E A<br> racJ9 [LF_ - ~ Ss! maas<br> <br><br> <br> max. 24.39 0.96 a n C<br>AL P [4]<br>EEJ2 & EJH2 (1-15A) <br> <br><br>C <br> <br>D T e. A B<br>E EJS8, EJHS8 & EJMS8 (1-15A)<br><br> Blue<br> Green/Yellow<br> D E Brown B<br> <br>L E:<br>EEJP & EJHP (1-15A)<br>C max. 24.39 0.96 C<br>C D a set<br>D as A at B ” ib F P [4]<br> <br>oH E | = be <br><br> <br><br> <br> <br>EJS1, EJHS1 & EJMS1 (1-15A) 20EEJ1 & 20EJH1<br>C<br>C<br>D<br>E =| BE A B C Ts D<br>J jy E t T A a B<br> <br> <br> <br> <br> <br> <br>A<br>A<br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
155
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Cost-effective Medium Performance Power Inlet Filter** _(continued)_
EEJ Series Including the EJH/EJHS, EJM/EJMS and EJS Models
**==> picture [494 x 595] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles (continued) R Recommended ecommended P Panel anel C Cutouts utouts<br>1 to 15A EEJ, EJH & EJM<br>20EJS1 Front Mount Back Mount<br>.820 .900<br>20.8 22.9<br>C F 1.200 3.56 .140 ∅ 1.200 3.56 .140 ∅<br>rae aN 30.48 Os 30.48<br>—— | — 1.575 4 — 1.575 —|<br>DE A B 40.01 3.05 .12 R.Typ. 40.01 5.94 .234 R.Typ.<br>= A] NS me N<br>Tolerances ± .005 [ 0.13 ] unless otherwise noted<br> <br> <br> <br> 20A EEJ & EJH<br>Front Mount Back Mount<br>1.055 .985<br>20EEJ8 & 20EJH8 26.8 25.02<br>C 1.370 .138 3.51 ∅ 1.300 .138 3.51 ∅<br>34.8 33.0<br>j Blue o _ 1.654 42.0 _ .118 3.0 R.Typ. 1.654 I 42.0 3.18 .125 R.Typ.<br>= Green/Yellow — | _ __ _<br>D E B F Tolerances ± .005 [ 0.13 ] unless otherwise noted<br>Brown<br>JI we Of <br>| 7<br>O71| F=| |@6<br>1 to 15A EJHS, EJMS & EJS<br>|-—— - A _ ——+| G R __ 4.775 0.188 Max.<br><br>0.815<br>[ EE = rh VA 20.70 <br> _ G E ST <br> <br> Tolerance ±.002 [.050]<br> <br> <br>20A EJS<br>1.450 0.125<br>20EJS8 36.83 R 3.175 Max.<br>pn<br>C<br><br>a n 4 1.053<br>Blue 26.75 <br>D E Green/YellowBrown B F <br>Tolerance ±.002 [.050]<br>(eI l,} Fezi(6||(CF ¢] P PC C Board Board Layout La —+ yout ———=<br>A 0.075<br>|-+——— —| 7 — 1.91 ∅<br>0.520<br> 13.21<br> <br> <br>0.551<br>.685* 13.99<br>17.40*<br>*±.015 [ 0.38 ]<br>**----- End of picture text -----**<br>
156
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Cost-effective Medium Performance Power Inlet Filter** _(continued)_
EEJ Series Including the EJH/EJHS, EJM/EJMS and EJS Models
## P Performance erformance D Data ata
## C Case ase D Dimensions imensions
## Typical Insertion Loss
**==> picture [493 x 460] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|A|B|C|D|E|F|
|Part No.||
|||||||Measured in closed 50 Ohm system|
||||||
|EEJ1, EJH1|
||||||
||
|EEJ & EJS Models|
||||||
|EJM1|
||||||
|1A|3A|
|15A1-10A EEJ2, EJH2|||||||||||||1009080db70||a||1009080db70|LTa|
|EEJ2, EJH2||||||60|EN|60|a|
|1-10A|I)|||||||4050|"<a|4050|,|
|30|A|_|30|Pall|Ci|
|EEJP15A|, EJHP||||||||||||20100|[TCO0|[IEi|20100|_—|1|COI_||
|EEJP, EJHP||||||0.1 1 10 30Frequency in MHz|0.1 1 10 30Frequency in MHz|
||||||
|EJS1, EJHS1|
||||||
|EJMS1|||||||||||6A100db|10A100db|
|EEE|90|||90|Co|TL|
||||||
|EEJ8, EJH8||||||8070|||8070|
|Oo||60|Ae|ie|a|60||Lae|
||||||50|ne|50|Air|
|EJM8|40|[AHI|40|[I|
||||||30|30|
|Oe|EJS8,||||||2010|__err;|0|nn|||2010|A|>|oe||eer|
|EJMS8EJHS8|||||||||||0|0.1 1 10 30|COI|Frequency in MHz|0|0.1 1 10 30|1)|COi|Frequency in MHz|
|||||
|20EEJ1,|||||||15A|20A|
|20EJH1||||||
|db|db|
|20EJS1|||||||10090|||10090|
||||||80|||80|
|ee|70|||70|||
|20EEJ8,|||||||60|||60|AE|
|20EJH8|||||||4050|en||4050|AELIC|vA||
|||||||30|ll|4|30|ll|—T|
|20EJS8|20|[I|ert|20|[||et|
|||||||10|60|10|Zeii||||
|Oo|0|0.1 1 10 30|et|i|I|0|0.1 1 10 30|Ce|iIe|
|Frequency in MHz|Frequency in MHz|
**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
**==> picture [162 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
20EJS1 3EJS1<br>**----- End of picture text -----**<br>
157
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Cost-effective Medium Performance Power Inlet Filter** _(continued)_
EEJ Series Including the EJH/EJHS, EJM/EJMS and EJS Models
## P Performance erformance D Data ata _(continued)_
## Typical Insertion Loss
Measured in closed 50 Ohm system
## EJH & EJHS Models
**==> picture [493 x 231] intentionally omitted <==**
**----- Start of picture text -----**<br>
1A 3A 6A 10A<br>db db db db<br>10090 | 10090 10090 10090 |<br>80 CI IP 80 eI IP 80 FEI | 80 CCIE oI<br>70 CI IP 70 II 70 FEI | 70 CCIE I<br>60 CCI IP 60 IIP 60 Fe I 60 CCIE I<br>50 CIC 50 Ie CI 50 Ce Ce) 50<br>40 ee 40 | | 40 a 40 |<br>30 30 30 30<br>Terre Cores CO ees Ces<br>20 fn 20 ee 20 20 |<br>10 CesT CI | 10 eI 10 eI 10 keer TT<br>0 0.1 1 10 30 CCI OCI 0 0.1 1 10 30 eI 0 0.1 1 10 30 er 0 0.1 1 10 30 TIF<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>15A 20A<br>db db<br>10060908070 CAICAI|AI I)I)I 10090608070 eeeeeeee<br>50 OI) 50<br>40 A, 40<br>30 CMI) = 30 Coe iiss<br>20 ar 20 ea<br>10 Padi 10 ee<br>0 ee 0 1<br>0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## EJM & EJMS Models
**==> picture [493 x 250] intentionally omitted <==**
**----- Start of picture text -----**<br>
1A 3A 6A 10A<br>db db db db<br>1009060805070 Cnn|||| 1009060805070 COCECICECICECICEI CIFCIFCIFCIFCI 1009060805070 TeoPENIPENIPENICIeI) 1009060805070 oooECTECTECTEINE<br>40 40 40 40<br>OE anti So COON -FI TITIES A CCT Cr CE TI ITE<br>30 ma 30 a ey, 30 ee 30 ti<br>20 Lai aes 20 Cert 20 20<br>100 CrtCem CCITIE 100 EeLee CT)I | 100 TICTI amrCIriess 100 OTeTTI aan aTTT<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>15A<br>db<br>1009060805070 nono|||CATE CTI Cer —- Common Mode / Asymmetrical (L-G)<br>40 CTI FoI TaN a Differential Mode / Symmetrical (L-L)<br>30 al<br>20 Ps<br>10 Car<br>0 0.01 0.1 1 10 30 Catteertti| in |<br>Frequency in MHz<br>**----- End of picture text -----**<br>
158
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Cost-effective Medium Performance Power Inlet Filter** _(continued)_
EEJ Series Including the EJH/EJHS, EJM/EJMS and EJS Models
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|** **|||** **|** **|** **|** **|** **||||** **||||** **|** **|** **|** **||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****|****||****|****||****|****|****|****|****|****|****||
|** **|||||||||||** **|||||||||||
|||||||||||||||||||||||
|||||||||||||||||||||||
|||||||||||||||||||||||
|||||||||||||||||||||||
|||||||||||||||||||||||
|||||||||||||||||||||||
|<br>** **|||||||||||<br>** **|||||||||||
|||||||||||||||||||||||
|<br><br><br><br>|<br><br><br><br>|<br><br><br><br>|<br><br><br><br>|<br><br><br><br>|<br><br><br><br>|<br><br><br><br>|<br><br><br><br>|<br><br><br><br>|<br><br><br><br>||<br><br><br><br>|<br><br><br><br>|<br><br><br><br>|<br><br><br><br>|<br><br><br><br>|<br><br><br><br>|<br><br><br><br>|<br><br><br><br>|<br><br><br><br>|<br><br><br><br>||
## EJM & EJMS Models
|** **<br>****<br><br><br><br><br>|****<br><br><br><br><br>|****<br><br><br><br><br>|** **<br>****<br>****<br><br><br><br><br><br><br><br><br><br>|** **<br>****<br>****<br><br><br><br><br><br><br><br><br><br>|** **<br>****<br>****<br>****<br><br><br><br><br><br><br><br><br><br><br><br><br><br><br>|****<br><br><br><br><br><br><br><br><br><br>||** **<br>****<br><br><br><br><br>|****<br><br><br><br><br>|****<br><br><br><br><br>|** **<br>****<br>****<br><br><br><br><br><br><br><br><br><br>|** **<br>****<br>****<br><br><br><br><br><br><br><br><br><br>|** **<br>****<br>****<br>****<br><br><br><br><br><br><br><br><br><br><br><br><br><br><br>|****<br><br><br><br><br><br><br><br><br><br>|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||j|j<br>pi {|||j|j|j|j|j|j|
|||||||||_EJM1_|||||||
||||||_EJMS1_||||||||||
159
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **EMI Power Inlet Filter**
## EF Series
UL Recognized CSA Certified VDE Approved*
## E EF F S Series eries
- Compact single stage EMI filter with IEC 60320-1 C14 inlet
- Two element circuit provides basic attenuation
- Available with an internal ground-circuit inductor (C suffix versions) to isolate equipment chassis from power line ground at radio frequencies
- Superseded by the EEA Series
## O Ordering rdering I Information nformation
## 3 EF 1F C
- L G Ground round C Circuit ircuit I Inductor nductor Omit if none
- O Output utput S Styles tyles 1F – .250 [ _6.3_ ] spade terminals _(back)_
**==> picture [208 x 90] intentionally omitted <==**
**----- Start of picture text -----**<br>
EF8<br>EF1F / EF1FC<br>EF4<br>EF2F<br>**----- End of picture text -----**<br>
## S Specifications pecifications
|S<br>pecifications<br>ecifications<br>cifications<br>ifications<br>fications<br>cations<br>ations<br>tions<br>ions<br>ons<br>ns<br>s<br>Specifications||
|---|---|
|Maximum leakage current each Line to Ground:|Maximum leakage current each Line to Ground:|
|@ 120 VAC 60 Hz:|.21 mA|
|@250 VAC 50 Hz:|.36 mA|
|Hipot rating (one minute):||
|Line to Ground:<br>Line to Line:|2250 VDC<br>1450 VDC|
|Rated Voltage (max.):|250 VAC|
|Operating Frequency:|50/60 Hz|
|Rated Current:|1 to 15A*|
|Operating Ambient Temperature Range||
|(at rated current Ir):<br>-10°C to +40°C<br>In an ambient temperature (Ta) higher than +40°C||
|the maximum operating current (Io) is ca|the maximum operating current (Io) is calculated as<br>follows: Io = Ir (85-Ta)/45|
## A Accessories ccessories
> G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord
- 2F – .250 [ _6.3_ ] spade terminals _(bottom)_
- 4 – Wire leads _(bottom)_
- 8 – Wire leads _(back)_
E EF F S Series eries
> C Current urrent R Rating ating 1, 3, 6, 10 or 15A
## Available Pailable Pilable Plable Pable Pble Ple Pe P Partrtt Numberumbermberbererrs Available vailable Pailable Pilable Plable Pable Pble Ple Pe P Partrtt Numberumbermberbererrs Part artrtt Numberumbermberbererrs Numbers Numberumbermberbererrs
## Available Pailable Pilable Plable Pable Pble Ple Pe P Partrtt Numberumbermberbererrs
||1EF1F|1EF2F|1EF4|1EF8|
|---|---|---|---|---|
||3EF1F|3EF2F|3EF4|3EF8|
||6EF1F<br>10EF1F|6EF2F|6EF4|6EF8|
||15EF1F||||
||Ground Circuit Inductor Versions||||
|10EF1FC<br>~~es~~||~~es~~|~~ee~~||
> F Paso! A601: Insulating Shroud
**==> picture [119 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
_ .413 Dia.<br>10.5<br>.271 Dia.<br>6.9<br>| F<br>.118<br>t 3.0 f \ of<br>1.39<br>35.4<br>a 29.7 1.17 ne .767 19.5<br>**----- End of picture text -----**<br>
_*15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC_
160
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **EMI Power Inlet Filter** _(continued)_
## EF Series
## E Electrical lectrical S Schematic chematic
**==> picture [494 x 569] intentionally omitted <==**
**----- Start of picture text -----**<br>
LINE LOAD EF8<br>1<br>F<br>Blue<br>2 7 aT D | E — Green/Yellow B er<br>= Brown<br>Z = ol<br>F<br> © ©<br>A<br>Case Styles<br>EF1F & EF1FC {Fa C<br>Case Styles =an<br>——- — — |<br>C <br> <br>D — | __ A ——" B<br>E<br>Dimensions Case Dimensions<br> Case<br> Part No. A B C D E F<br> <br>EF2F 1EF1F, 3EF1F,6EF1F <br>1EF2F, 3EF2F, <br>C 6EF2F <br>1EF4, 3EF4, <br>Lt To .6516.5 Max. LI 6EF4 <br>Ch EEG<br>D 1EF8, 3EF8, <br>al E OS A peep B I 6EF8 <br> 10EF1F,10EF1FC <br> <br> 15EF1F <br> <br>EF4<br>o @ } ' C Recommended Panel Cutouts<br>a c t | oy oO 2 | Recommended Panel Cutouts<br>Front Mount Back Mount<br>D<br>Pa E CW A F TOGM B me 1.200 ATNa 20.8 .820 3.56 .140 we 1.200 + .900 22.9 3.56 .140 <br>30.48 30.48<br>1 — 7<br>1.575 1.575<br>40.01 .062 1.58 _ R.Typ. 40.01 5.94 .234 _ R.Typ.<br>F Tolerances ± .005 [ 0.13 ] unless otherwise noted<br> <br> <br> <br>Brown Blue<br>Green/Yellow<br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
161
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **EMI Power Inlet Filter** _(continued)_
## EF Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [517 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
1EF 3EF 6EF 10EF<br>db db db db<br>10090 | 10090 || 10090 | 10090 |<br>80 CoE ie 80 || 80 CC 80 CIE<br>70 CCE ir 70 | 70 EC 70 CIE C ie<br>60 | 60 el 60 a 60 CCE<br>50 on —. 50 nl 50 en 50 Ii _<br>40 oP. 40 ae 40 [Cem oo 40 [CCI Loe<br>30 AT I 30 eer | 30 en) 30 LT ee<br>2010 a 2010 am 2010 _Pl 2010 _a<br>0 0.1 1 10 30 0 0.1 1 10 30 0 0.1 1 10 30 ef| 0 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
**==> picture [115 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
15EF<br>db<br>100409060805070 EYCOCOCCONCOCOC CIECIECeron-IEoCICeeCee CiiS<br>30 COT Fg<br>20100 COOeaenCorr<br> 0.01 0.1 1 10 30<br>Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
|** **|||** **|** **|** **||
|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|
|****|||||||
||||||||
||||||||
||||||||
||||||||
||||||||
|****|||||||
||||||||
||||||||
||||||||
|****|||||||
||||||||
162
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **High Performance Power Inlet Filter**
## EJT Series
UL Recognized CSA Certified VDE Approved*
**==> picture [138 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
EJT1 EJT8<br>**----- End of picture text -----**<br>
## S Specifications pecifications
## E EJT JT S Series eries
- Superior EMI filter with IEC 60320-1 inlet
Maximum leakage current each Line to Ground:
||1-15A|20A|
|---|---|---|
|@ 120 VAC 60 Hz:<br>@250 VAC 50 Hz:|.25 mA<br>.43 mA|.22 mA<br>.40 mA|
|Hipot rating (one minute):<br>Line to Ground:||2250 VDC|
|Line to Line:||1450 VDC|
|Rated Voltage (max.):||250 VAC|
|Operating Frequency:||50/60 Hz|
|Rated Current:||1 to 20A*|
- Double three element differential mode circuit attenuates noise up to 1GHz
- Up to 15A with IEC 60320-1 C14 inlet
- 20A rating with IEC 60320-1 C20 inlet
- Spade terminals or wire leads
## O Ordering rdering I Information nformation
6 EJT 1 ~~L~~ O Output utput Styles Styles 1 – .250 [ _6.3_ ] spade terminals 8 – Wire leads
Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
E EJT JT S Series eries C Current urrent R Rating ating 1, 3, 6, 10, 15 or 20A
A Accessories ccessories G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord
## Available Part Numbersvailable Part Numbersailable Part Numbersilable Part Numberslable Part Numbersable Part Numbersble Part Numbersle Part Numberse Part Numbers Part Numbersart Numbersrt Numberst Numbers Numbersumbersmbersbersersrss Available Part Numbers
## Available Part Numbersvailable Part Numbersailable Part Numbersilable Part Numberslable Part Numbersable Part Numbersble Part Numbersle Part Numberse Part Numbers Part Numbersart Numbersrt Numberst Numbers Numbersumbersmbersbersersrss
**==> picture [431 x 131] intentionally omitted <==**
**----- Start of picture text -----**<br>
1EJT1 1EJT8<br>3EJT1 3EJT8<br>6EJT1 6EJT8<br>10EJT1 10EJT8<br>F FA6O1 A601: Insulating Shroud (fits 1-15A only)<br>15EJT1 15EJT8 .413 Dia.<br>10.5<br>20EJT1 20EJT8 .271 Dia.<br>6.9<br>/ ft<br>T .118 T<br>3.0<br>1.39<br>*15A versions are tested by Underwriters Laboratories 35.4<br>to US and Canadian requirements and are inl a 29.7 1.17 |2 jb [| .767 19.5<br>**----- End of picture text -----**<br>
- _*15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC._
- _20A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 16A, 250VAC._
163
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **High Performance Power Inlet Filter** _(continued)_
## EJT Series
**==> picture [231 x 86] intentionally omitted <==**
**----- Start of picture text -----**<br>
E Electrical lectrical S Schematics chematics<br>LINE LOAD<br>1<br>1<br>ILS<br><br>**----- End of picture text -----**<br>
**==> picture [217 x 168] intentionally omitted <==**
**----- Start of picture text -----**<br>
20EJT8<br>Blue<br>D E Green/YellowBrown B<br>se<br>/+¥ — —|<br>C<br><br> <br><br> <br> <br>A<br>**----- End of picture text -----**<br>
**==> picture [494 x 486] intentionally omitted <==**
**----- Start of picture text -----**<br>
Case Styles C<br>EJT1<br><br> <br><br>C <br> <br>B<br>ee DE ee A ) Case Dimensions<br> A B C D E<br> Part No.<br> <br> <br> EJT1 <br> <br>20EJT1 <br>EJT8<br> <br>= = A C y 20EJT1 CO <br> <br>B <br>D 20EJT8<br>E A <br><br> <br><br> <br> R Recommended ecommended P Panel anel C Cutouts utouts<br> <br>EJT8 1 to 15A 20A<br>1.575 1.654<br>40.00 42.01<br>Blue<br>= “i Green/Yellow S|© p oa 30.48 1.20 — —a 34.80 1.370<br>D E B<br>Brown<br>= = | | 8}) jroo 7<br>.820 1.055<br>| a | © 20.83 i ft 26.80<br>H+ ° “4 ;<br>0.140 .062 0.138 .062<br>Dia. R Max. Dia. R Max.<br>3.56 1.57 3.51 1.57<br>_ [f] [o] Front Mount Only<br>Tolerance ±.005 [.13]<br>C<br>t| be<br><br> <br><br> <br> <br>A<br>**----- End of picture text -----**<br>
164
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **High Performance Power Inlet Filter** _(continued)_
## EJT Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [514 x 246] intentionally omitted <==**
**----- Start of picture text -----**<br>
1EJT 3EJT 6EJT 10EJT<br>db db db db<br>10090 COLL o_o 10090 COL oo 10090 COLO oo 10090 COIL o_o<br>80 a 80 CO Co CC 80 COO CAG Oil 80 COCOA Cal Oil<br>70 70 70 70<br>60 See ALi 60 en Mo 60 maa Vani 60 CO |an<br>50 50 50 50<br>40 40 40 40<br>302010 LuCTE CIE1 A 302010 MA 302010 — 302010 Cu<br>0 ¢ |Co ol 0 Lfi) 0 : 0 —<br> 0.1 1 10 100 1000 0.1 1 10 100 1000 0.1 1 10 100 1000 0.1 1 10 100 1000<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>15EJT 20EJT<br>db db<br>1009060805070 VYA|CCITT Zr |, II 1009060805070 COILaCIECOIo_oWALIANAL II Common Mode / Asymmetrical (L-G)<br>40 40 Differential Mode / Symmetrical (L-L)<br>30 Bn NY aiid, 30 Zl i —<br>20 20<br>10 10<br>0 0.1 1 10 100 1000 CICA CA COT 0 0.1 1 10 100 1000 2<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
|** **<br>****<br><br><br><br>|****<br><br><br><br>|****<br><br><br><br>|** **<br>****<br><br><br><br>|** **<br>****<br>****<br>****<br><br><br><br><br><br><br><br><br><br><br><br>|** **<br>****<br>****<br>****<br><br><br><br><br><br><br><br><br><br><br><br>|** **<br>****<br>****<br>****<br><br><br><br><br><br><br><br><br><br><br><br>|****<br><br><br><br><br><br><br><br>|****<br><br><br><br><br><br><br><br>||** **<br>****<br><br><br><br>|****<br><br><br><br>|****<br><br><br><br>|** **<br>****<br><br><br><br>|** **<br>****<br>****<br>****<br><br><br><br><br><br><br><br><br><br><br><br>|** **<br>****<br>****<br>****<br><br><br><br><br><br><br><br><br><br><br><br>|** **<br>****<br>****<br>****<br><br><br><br><br><br><br><br><br><br><br><br>|****<br><br><br><br><br><br><br><br>|****<br><br><br><br><br><br><br><br>|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||||||||||
||||||||||||||||||||
165
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Smallest Power Entry Module with Metric Fuse Holders**
## GG & HG Series
UL Recognized CSA Certified VDE Approved
**==> picture [125 x 13] intentionally omitted <==**
**----- Start of picture text -----**<br>
GG1<br>GG8<br>**----- End of picture text -----**<br>
## G GG G S Series eries
- Power entry module with enhanced EMI filter
- Single or dual fusing
- Two element circuit provides basic attenuation
- Available with an internal ground-circuit inductor (C versions) to isolate equipment chassis from power line ground at radio frequencies
- Multiple termination and mounting styles
## H HG G S Series eries
- Medical version of our GG Series
- Mechanically identical to GG Series
## S Specifications pecifications
**==> picture [243 x 145] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Maximum leakage current each Line to Ground:|
|HG Models|GG Models|
|@ 120 VAC 60 Hz:|2 A|.25 mA|
|@250 VAC 50 Hz:|5 A|.42 mA|
|Hipot rating (one minute):|
|Line to Ground:|2250 VDC|
|Line to Line:|1450 VDC|
|Rated Voltage (max.):|250 VAC|
|Operating Frequency:|50/60 Hz|
|Rated Current:|1 to 10A|
|Required Fuse(s):|5 x 20mm|
|(not included)|
**----- End of picture text -----**<br>
- Available only with dual fusing
> O Ordering rdering I Information nformation 3 E GG 1 C -2 ~~L~~ M Metric etric F Fuse use H Holders olders 1 – Single 2 – Double Ground Circuit Inductor Omit if none
> O Output_— utput S Styles tyles 1 – .250 [ _6.3_ ] spade terminals 8 – Wire leads
> G GG G o or r H HG G S Series eries _(Flange mount)_
> G GGS GS o or r H HGS GS S Series eries _(Snap-in mount)_ Leakage current designation E – Low leakage _(<0.5 mA)_ C Current— urrent R Rating ating 1, 3, 6 or 10A
**==> picture [241 x 232] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|A|Available|vailable P|Part|art|Numbers|Numbers|
|TT|Filtered modules|
|1EGG1-1|3EGG1-1|6EGG1-1|10EGG1-1|
|1EGG1-2|3EGG1-2|6EGG1-2|10EGG1-2|
|1EGG8-1|3EGG8-1|6EGG8-1|10EGG8-1|
|1EGG8-2|3EGG8-2|6EGG8-2|10EGG8-2|
|1EGS1-1|3EGS1-1|6EGS1-1|10EGS1-1|
|1EGS1-2|3EGS1-2|6EGS1-2|10EGS1-2|
|tid.|
|Filtered modules with ground circuit inductor|
|1EGG1C-1|3EGG1C-1|6EGG1C-1|
|1EGG1C-2|3EGG1C-2|6EGG1C-2|
|1EGG8C-1|3EGG8C-1|6EGG8C-1|
|1EGG8C-2|3EGG8C-2|6EGG8C-2|
|Medical filter modules|
|1EHG1-2|3EHG1-2|6EHG1-2|10EHG1-2|
|1EHG8-2|3EHG8-2|6EHG8-2|10EHG8-2|
|1EHGS1-2|3EHGS1-2|6EHGS1-2|10EHGS1-2|
|ee|
**----- End of picture text -----**<br>
166
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Smallest Power Entry Module with Metric Fuse Holders** _(continued)_
## GG & HG Series
**==> picture [492 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
E Electrical lectrical S Schematic chematic GG8 & HG8<br>LINE LOAD<br>1<br>Blue<br>2<br>3<br>ie) : O en| D E aa Green/Yellow a B<br>3 Brown<br>SOR Ey© E ELo<br> ~~ ——|<br><br><br> C<br>[ oe<br>A<br>**----- End of picture text -----**<br>
__ __ __
## A Accessories ccessories
> G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord
## Case Dimensionsase Dimensionsse Dimensionse Dimensions Dimensionsimensionsmensionsensionsnsionssionsionsonsnss ~~Case Dimensions~~
Case Dimensionsase Dimensionsse Dimensionse Dimensions Dimensionsimensionsmensionsensionsnsionssionsionsonsnss A B C D E Part No. __ ** ** GG1 & HG1 _ _ ~~ee~~ ** ** GG1C _ _ ** ** GS1, HGS1 __ ~~Ess~~ _ _ ** ** GG8, HG8 _ _
**==> picture [366 x 304] intentionally omitted <==**
**----- Start of picture text -----**<br>
Case Styles <br>Case Styles<br>GG1, GG1C & HG1 GG1C <br><br><br>GS1, HGS1<br><br>C<br><br>GG8, HG8<br><br>D<br>ot E | A ee B<br> R Recommended ecommended Pacommended Paommended Pammended Pamended Paended Panded Paded Paed Pad Pa Pa<br> GG / HG<br> <br> <br> 1.14<br>29.0<br>GS1 & HGS1<br>><br>1.30<br>33.0<br>D C<br>| |<br>1.417<br>E A B 36.0<br>- — IPE+ R S ) LSaa<br> Front or Back Mount<br> <br> <br> <br>**----- End of picture text -----**<br>
## R Recommended ecommended Pacommended Paommended Pammended Pamended Paended Panded Paded Paed Pad Pa Pa Panel anel C Cutouts utouts
**==> picture [213 x 172] intentionally omitted <==**
**----- Start of picture text -----**<br>
GG / HG GS / HGS<br>1.14 1.24<br>29.0 31.5<br>> + + 7<br>1.30 1.29<br>33.0 32.8<br>1.417<br>36.0<br>LSaa<br>Front or Back Mount Front Mount Only<br><br> <br> <br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
167
**te.com/help**
**corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Smallest Power Entry Module with Metric Fuse Holders** _(continued)_
## GG & HG Series
## P Performance erformance D Data ata
## Typical Insertion Loss Measured in closed 50 Ohm system GG & GS Models
**==> picture [493 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
1A 3A 6A 10A<br>db db db db<br>10090 10090 10090 10090 COCon Co<br>80 80 | 80 80 COIE Coie<br>70 70 | 70 70 COIE Coie<br>60 60 60 60 CO<br>50 > ame! 50 ——" 50 =, 50 IEIE Coie<br>40 LU LC _| 40 LT 40 [TTI ot 40 ED,CTT ae<br>30 | 30 _ 30 a atl 30 CO Caan<br>20 AIi 20 =— 20 = Ce 20 COI aA<br>10 CoE ie 10 10 a 10 CO ae<br>0 0.1 1 10 30 Co Coir 0 0.1 1 10 30 0 0.1 1 10 30 LConi Tiir F 0 0.01 0.1 1 10 30 eTTI 7<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## 3A GG1C 6A GG1C
**==> picture [240 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db<br>100 100<br>90 LOL To 90 | |||<br>80 CoE ie 80 ||<br>605070 Coe0| = 605070 en|||| -<br>40 = 40 CIE<br>30 ——— 30 n=<br>20 20 —<br>10 10<br>0 0<br>0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## HG Models
## 6A 10A
## 1A 3A
**==> picture [240 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db<br>10090 0 10090 ||<br>8070 0| 8070 ||<br>60 0 60 ||<br>50 CoE ie 50 |<br>40 heel | | 40 CPE<br>3020 AZTECLL 3020 Cu<br>10 | os 10 =<br>0 0.1 1 10 30 CCoi Coir 0 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
**==> picture [240 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db<br>10090 | 10090 a<br>8070 CCIE Ce 8070 CIEie<br>60 |a 60 CIE|Cie<br>50 | 50 |<br>40 le 40 [Ce _I LT<br>3020 nD a 3020 eal LOETI<br>10 P= CCE 10 I CC<br>0 0.1 1 10 30 L Coir|Tir 0 0.1 1 10 30 Cat66Cri 1<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|** **|||** **|** **|** **|** **|** **||||** **|||** **|** **|** **|** **|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****|****||****|****|****|****|****|****|****|****|****|
|** **|||||||||||** **|** **||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|** **|||||||||||** **|||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
168
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Power Inlet Line Filter for Medical Equipment**
## H Series
UL Recognized CSA Certified VDE Approved*
**==> picture [159 x 72] intentionally omitted <==**
**----- Start of picture text -----**<br>
EH8<br>EH9<br>EH4<br>EH1 EH5<br>**----- End of picture text -----**<br>
## H Seriesriesiesess FH Seriesriesiesess Series eriesriesiesess
## H Seriesriesiesess
- Minimal leakage current suitable for medical equipment
- Two element circuit provides basic EMI attenuation above 1 MHz
- Available with an internal ground circuit inductor (C suffix versions) to isolate equipment chassis from power line ground at radio frequencies
- Flanged mounting the same as the EC, ED and EF Series
- Capacitive output (see EAH, EBH and EJH Series for capacitive input)
## O Ordering rdering I Information nformation
## 3 E H 1 C
- ~~L~~ G Ground round C Circuit ircuit I Inductor nductor Omit if none
> O Output utput S Styles tyles Chassis Mount Style ~~oe~~ 1 – .250 [ _6.3_ ] spade terminals 3 – Wire leads
## S Specifications pecifications
Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz: 2 A @250 VAC 50 Hz: 5 A Hipot rating (one minute): Line to Ground: 2250 VDC Line to Line: 1450 VDC Rated Voltage (max.): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 to 15A* Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir ~~~~ (85-Ta)/45
## E Electrical lectri ; cal S Schematic chemati . c
LINE LOAD 1 ~~xe~~
Power Inlet Style *
- 4 – .250 [ _6.3_ ] spade terminals _(back)_
- 5 – Wire leads _(bottom)_
- 8 – Wire leads _(back)_
- 9 – .250 [ _6.3_ ] spade terminals _(bottom)_
H H S Series eries
> L Leakage eakage c current urrent d designation esignation E – Low Leakage _(<0.5 mA)_
C Current urrent R Rating ating 3, 6, 10 or 15A
## A Available vailable P Part art N Numbers umbers
|3EH1<br>3EH3<br>6EH1<br>6EH3|6EH8<br>6EH9<br>10EH1<br>10EH3|
|---|---|
|6EH4<br>6EH5|10EH4<br>15EH4|
|Ground Circuit Inductor Versions||
|10EH4C||
- _*15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC_
- _*IEC 60320-1 C14 inlet mates with C13 connector_
169
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Power Inlet Line Filter for Medical Equipment** _(continued)_
## H Series
**==> picture [494 x 587] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles H5<br>H1 (Chassis Mount)<br>C<br>a ( ay s -<br>D<br>E B D<br>E A<br>B<br>F<br>is A C 4 or<br> F<br> . z e<br> <br> <br> <br>H3 (Chassis Mount) H8<br>F<br>Blue<br>E D B Green/Yellow<br>D E B<br>Brown<br>i+ (0) eE a E al | (34 F<br>A<br>J SP A |OA C fell Ea<br><br> C<br> a<br>H4 & H4C <br> <br> <br>C<br>©)<br>D A B<br>c E =| —— = R Recommended ecommended Panel Panel Cutouts Cutouts<br><br> Front Mount Back Mount<br> <br> .820 .900<br>H9 C 1.200 it 20.8 3.56 .140 7 1.200 s 22.9 3.56 .140 <br>30.48 30.48<br>C e 40.01 1.575 an .062 1.58 R.Typ. 40.01 1.575 5.94 .234 R.Typ.<br> .65 Max. Tolerances ± .005 [ 0.13 ] unless otherwise noted<br>16.5<br>Been.<br>D <br>E A B <br> Be) SG<br> <br> <br> <br>Brown Blue<br>Green/Yellow<br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
170
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Power Inlet Line Filter for Medical Equipment** _(continued)_
## H Series
## P Performance erformance D Data ata
## C Case ase D Dimensions imensions
**==> picture [344 x 254] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|A|B|C|D|E|F|
|Part No.||
|||||||
|H1|||||||3EH|
||||||db|
|100|
|OO|H3|||||||908080|COCOECOE|CIEonI-onI-|
||||||70|
|ee|6070|COECOE|CIECIE CeeCee|
|6EH4|||||||40505030|COECOICOIi=CCIECIECIE|CCIECIECIE|
||||||30|i=CCIECIECIE|
|Oe|20|
|10EH4,10EH4C||||||||||||1000|DPACOACO|alerer =|
|15EH4|||||||
||||||10EH|
|H5|a|||||||||||||1009080db9080db80db|||||||||
|es|70|O00|||
|H8|||||||6070||||
|||||||50|||Ee|
|a|4050|Ee|
|H9|||||||302020|Oo|
||||||10|a|||
|Send|CAI|||
**----- End of picture text -----**<br>
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [240 x 133] intentionally omitted <==**
**----- Start of picture text -----**<br>
3EH 6EH<br>db db<br>100 100<br>908080 COCOECOE CIEonI-onI- Cee_ 9080 mirl mnCHTh<br>6070 COECOECOE CIECIECIE CeeCee 6070 ni CH<br>40505030 COECOICOIi=CCIECIECIE CAECee 405030 aIEie<br>20 20 DS<br>1000 CODPACOACO alerer = 100 arCoeeCri 7<br>0.01 0.1 1 10 30 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>10EH 15EH<br>**----- End of picture text -----**<br>
**==> picture [242 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db db<br>10090 COO<br>1009080db9080db80db ||||||| 80 COOConOI ToCoe<br>es 6070 O00|| 6070 COOCOOOI Coe<br>4050 ||Ee 4050 a|I Coe<br>30<br>302020 Oo 20 a<br>10 a | 10 Con<br>0 CAI|| 0 A— i<br>0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## A Accessories ccessories
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
> G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
F FA6OI A601: Insulating Shroud
**==> picture [147 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
.413 Dia.<br>10.5<br>.271 Dia.<br>6.9<br>| F<br>t .118 f<br>3.0 |<br>| 1.39<br>35.4<br>a 29.7 1.17 —|— .767 19.5<br>**----- End of picture text -----**<br>
**==> picture [209 x 89] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
| | |
||||||||
|a|
||||||||
||||||||
||||||||
||||||||
**----- End of picture text -----**<br>
171
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Power Entry Module with Voltage Selection and Fusing**
## J Series
UL Recognized CSA Certified
**==> picture [180 x 80] intentionally omitted <==**
**----- Start of picture text -----**<br>
Front View, all models<br>6J4<br>8<br>6HJ4<br>**----- End of picture text -----**<br>
## J J S Series eries
- Power entry module with North American style 3AG fuse holder
- 2 or 4 voltage selection
- Compact snap-in design
- Two element circuit provides basic EMI attenuation
- Available with minimal leakage current suitable for medical applications (HJ models)
- Also available without filter (VJ models)
## O Ordering rdering I Information nformation
## 6 H J 4 -4
L_ Available Available Voltage Voltage Selections Selections 1 - Four _(non–filtered versions)_ 2 – Two 4 or blank – Four _(filtered versions)_ F Filtered iltered I Indicator ndicator 1 – Non–filtered 4 – Filtered
J J S Series eries F Filter ilter T Type ype H – Medical V – Non-filtered Blank – general purpose Current Rating 6A current Neng
## S Specifications pecifications
Maximum leakage current each Line to Ground:
|||6HJ4 or|
|---|---|---|
|@250 VAC 50 Hz:|6J4 Models<br>500A|non–filtered<br>5A|
|Hipot rating (one minute):<br>Line to Ground:<br>Line to Line:||1550 VAC<br>1450 VDC|
|Operating Voltage:<br>suffix - 1 or - 4 models:|100, 120, 220 or 240VAC|100, 120, 220 or 240VAC|
|suffix - 2 models:||115 or 230 VAC|
|Operating Frequency:||50/60 Hz|
|Rated Current:<br>Required Fuse:||6A<br>.25 x 1.25|
|||_(not included)_|
## A Available vailable P Part art N Numbers umbers
Non–filtered models 6VJ1 ~~|~~ 6VJ1-2 General Purpose Filters 6J4 6J4-2 Medical Filters 6HJ4-4 6HJ4-2 ~~i~~
172
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Power Entry Module with Voltage Selection and Fusing** _(continued)_
## J Series
## E Electrical lectrical S Schematics chematics
## 6VJ1 & 6VJ1-2
**==> picture [228 x 365] intentionally omitted <==**
**----- Start of picture text -----**<br>
Note 3<br>120V 220V<br>Note 2 100V 240V<br>Hot A A<br>S R Power On/Off 20V<br>Off B B<br>100V<br>H<br>On J C<br>Ground Pilot<br>| : light D D<br>K E 120V<br>Note 2 M<br>L F<br>nen Neutral P N T Note 1 oe Transformerprimary<br>6J4 & 6J4-2<br>Note 3<br>120V 220V<br>100V 240V<br>A A<br>Power On-Off 20V<br>Hot Off B B 100V<br>C al C<br>Ground (° On Pilot LSak4+¢ 4<br>light D D<br>E E 120V<br>Neutral J<br>‘ leg H F e n! F<br>Note 1 Transformer<br>primary<br>6HJ4-4 & 6J4-2<br>Note 3<br>120V 220V<br>100V 240V<br>A A<br>20V<br>Power On-Off on<br>Hot Off [vara B B | 100V<br>C | C<br>Ground On Pilot<br>light D D<br>E E 120V<br>Neutral J<br>o r H Sra F F<br>Note 1 Transformer<br>primary<br> <br> <br> <br>**----- End of picture text -----**<br>
## V Voltage oltage S Selection election
## A Accessories ccessories
> G GA400 A400:NEMA 5-15P to IEC 60320-1 C-13 line cord
JA302: 2 Voltage Select Card JA302
Comes standard with 6VJ1-2, 6J4-2 and 6HJ4-2
> J JA304 A304: 4 Voltage Select Card
Comes standard with 6VJ1, 6J4 and 6HJ4-4
> JA A40 403: Mounting clips for .105 - .125” panels JA410 ~~-~~ 419: Equipment Rating Labels JA410 ~~-4~~ 19: Self-adhesive, available in multiples of 40 Specify part number
**==> picture [237 x 227] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.330<br>.210 Line V. + 5 - 10% Fuse 100/120V (115V) 220/240V (230V)<br>48-440 - 50 VA Max. 500mA 250mA<br>i | ——}+ —|<br>A B C<br>@<br> A B C<br>VA Fuse Fuse<br>Part No. max. 100/120 (115) 220/240 (230)<br> JA410 25 250 mA 125 mA<br> JA411 50 500 mA 250 mA<br> JA412 100 1A 500 mA<br> JA413 200 2A 1A<br> JA414 250 2.5A 1.25A<br> JA415 300 3A 1.5A<br> JA416 400 4 A 2A<br> JA417 500 5A 2.5A<br> JA418 600 6A 3A<br> JA419 Assortment<br> JA410-JA418: 40 labels of one part number<br> JA419: 5 each of JA410 - JA418 (45 labels)<br>**----- End of picture text -----**<br>
Open cover door and slide fuse-pull lever to left. Select operating voltage by orienting voltage selection card with the desired voltage on top left side. Push card firmly into module slot. Slide fuse-pull lever to right into normal position and re-insert fuse into holders.
J JASOO A500: Voltage Selector Card Extractor Tool
Use caution in selecting correct fuse value.
173
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Power Entry Module with Voltage Selection and Fusing** _(continued)_
## J Series
## C Case ase S Styles tyles
## Non-filtered Models
**==> picture [241 x 269] intentionally omitted <==**
**----- Start of picture text -----**<br>
C<br>D<br>a A<br>B<br><br> <br> <br>Filtered Models<br>————<br>: @e||<br>C<br>ULa |<br>——s (<br>— D<br>A<br> = B<br><br> <br> <br>**----- End of picture text -----**<br>
## Filtered Models
## C Case ase D Dimensions imensions
**==> picture [229 x 76] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|A|B|C|D|
|Part No.|
|||||
|||||
|6VJ1, 6VJ1-2|
|||||
|6J4, 6J4-2,|||||
|6HJ4-4, 6HJ4-2|||||
**----- End of picture text -----**<br>
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [240 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
6J4 6HJ4<br>db db<br>100 100<br>90 Et 90 ne<br>80 80<br>70 CCHS 70 Eo<br>60 60<br>50 Con 50 ee<br>40 40<br>30 a 30 =H<br>20 C4 20 ee<br>10 PF 10 |<br>0 0<br>0.1 1 10 30 aii co 0.1 1 10 30 __<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## R Recommended ecommended P Panel anel C Cutouts utouts
**==> picture [479 x 171] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Door Open Position|
|Minimum Insertion Loss|
|1.063*|1.17|Measured in closed 50 Ohm system|
|27.0|29.7|
|Common Mode / Asymmetrical (Line to Ground)|
|Bezel|2.60*| |
|Clearance||____|66.0|___|___,|*± .003 [|.076|]| ||||||||
|2.68|||||||||
|68.1|
|3.00|||||||||
|76.2|
||||
||
||
**----- End of picture text -----**<br>
174
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Dual Configuration Power Entry Module**
## L Series
UL Recognized CSA Certified VDE Approved
_EDL4C / EHL4C_
_EDL1S / EHL1S_
## L Seriesriesiesess L Seriesriesiesess Series eriesriesiesess
## L Seriesriesiesess
- Power entry module with switch or fuse
- For 10A capability and high performance filtering see the P Series on page 192
- Two element circuit provides extended EMI attenuation similar to EAB inlet filter
- North American or metric fuse holders
- Available with minimal leakage current for medical applications (HL models)
## O Ordering rdering I Information nformation
## 6 E D L 1 S C M
L Fuseholder Fuseholder Type Type _(pre-installed)_ M – Metric Omit for North American
> M Mounting ounting T Type ype C– Snap-In Omit for flange mount
## S Specifications pecifications
Maximum leakage current each Line to Ground:
|@ 120 VAC 60 Hz:<br>@ 250 VAC 50 Hz:|DL Models<br>.25 mA<br>.50 mA|HL Models<br>2A<br>5A|
|---|---|---|
|Hipot rating (one minute):|||
|Line to Ground:||2250 VDC|
|Line to Line:||1450 VDC|
Operating Voltage: 1S & 1SC models (fixed): 250 VAC max. 4 & 4C Suffix: 100, 120, 220 or 240 VAC. Operating Frequency: 50/60 Hz Rated Current: 2 to 6A Required Fuse(s): North American: one .25 x 1.25” _(not included)_ Metric: two 5 x 20mm _(not included)_ Switch: DPST 10,000 operations at 51A max. inrush
S Switch witch O Option ption S – DPST on/off switch Omit for none
> V Voltage oltage S Selection election P Positions ositions 1 or 4
L L S Series eries
F Filter ilter T Type ype D – General Purpose H – Medical omit for none
> L Leakage eakage c current urrent d designation esignation E – Low Leakage _(<0.5 mA)_
C Current urrent R Rating ating 2, 4 or 6A
175
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Dual Configuration Power Entry Module** _(continued)_
## L Series
|L Series|L Series|||||
|---|---|---|---|---|---|
|A<br>v<br>a<br>i<br>l<br>a<br>b<br>l<br>e<br>P<br>a<br>r<br>t<br>N<br>u<br>m<br>b<br>e<br>r<br>s<br>Available Part Numbers||North American Fusing||Metric Fusing||
|||Flange Mount|Snap-In|Flange Mount|Snap-In|
|Non-Filtered|Single Voltage,<br>Switched|6EL1S|6EL1SC|6EL1SM|6EL1SCM|
||4 Voltage Select,<br>No Switch|6EL4|6EL4C|6EL4M|6EL4CM|
|General<br>Purpose Filter|Single Voltage,<br>Switched|2EDL1S<br>4EDL1S<br>6EDL1S|2EDL1SC<br>4EDL1SC<br>6EDL1SC|2EDL1SM<br>4EDL1SM<br>6EDL1SM|2EDL1SCM<br>4EDL1SCM<br>6EDL1SCM|
||4 Voltage Select,<br>No Switch|2EDL4<br>4EDL4<br>6EDL4|2EDL4C<br>4EDL4C<br>6EDL4C|2EDL4M<br>4EDL4M<br>6EDL4M|2EDL4CM<br>4EDL4CM<br>6EDL4CM|
|Medical Filter|Single Voltage,<br>Switched|6EHL1S|6EHL1SC|6EHL1SM|6EHL1SCM|
||4 Voltage Select,<br>No Switch|6EHL4|6EHL4C|6EHL4M|6EHL4CM|
## V Voltage oltage S Selection election
To change selected voltage: disconnect the power cord; open cover using a small blade screwdriver or similar tool; insert the tool into the voltage selection slot and remove wheel from unit; select desired voltage; replace wheel into unit and close cover, making sure the selected voltage appears in connector window.
## R Recommended ecommended P Panel anel C Cutouts utouts
**==> picture [236 x 243] intentionally omitted <==**
**----- Start of picture text -----**<br>
.06<br>R<br>oN 1.52 ‘<br>2.201*<br>(1)<br>a 55.91<br>(3) (3)<br>2.213*<br>(2)<br>.020 56.21<br>(4) R<br>.508<br>1.122*<br>*+.008 -.00<br>28.50 +.203 -.00<br>1.575<br>(3)<br>40.00<br> <br> <br> <br> <br> <br><br>**----- End of picture text -----**<br>
176
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Dual Configuration Power Entry Module** _(continued)_
## L Series
## E Electrical lectrical S Schematics chematics
## DL Models
## A Accessories ccessories
> G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord
## Single Voltage, Switched (DL1S)
**==> picture [241 x 92] intentionally omitted <==**
**----- Start of picture text -----**<br>
Customer<br>Note 2 Transformer<br>Note 1 H On/Off Primaries<br>Neutral<br>2 1<br>Ground (1) (1a)<br>(2) (2a)<br>4 3 Device<br>Hot 2.<br>G<br>**----- End of picture text -----**<br>
> L LA303 A303: Voltage Select Wheel, 3 position Selection drum for use with L4 models. Marked with 110V, 220V and 240V
## 4 Voltage Select, No-Switch (DL4)
**==> picture [23 x 67] intentionally omitted <==**
**----- Start of picture text -----**<br>
Hot<br>Ground<br>Neutral<br>**----- End of picture text -----**<br>
**==> picture [149 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
Customer<br>120V 220V Transformer<br>100V 240V Primaries<br>Note 1 G On/OffNote 2 A A oO A 20V<br>B B B<br>; Oo 100V<br>C C C<br>D D D<br>E E E 120V<br>F F F<br>H<br>**----- End of picture text -----**<br>
> L LA304 A304: Voltage Select Wheel, 4 position
Selection drum for use with L4 models. Marked with 100V, 110V, 220V and 240V.
One LA304 comes standard with each L4 model.
## HL Models
## Single Voltage, Switched (HL1S)
**==> picture [241 x 89] intentionally omitted <==**
**----- Start of picture text -----**<br>
Customer<br>Note 2 Transformer<br>Note 1 H On/Off Primaries<br>Neutral<br>2 1<br>Ground (1) (1a)<br>(2) (2a)<br>4 3 Device<br>Hot<br>G<br>**----- End of picture text -----**<br>
## 4 Voltage Select, No-Switch (HL4)
**==> picture [239 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
Customer<br>120V 220V Transformer<br>100V 240V Primaries<br>Note 2 A A A<br>Hot Note 1 G On/Off 20V<br>B B B<br>: oO 100V<br>C C C<br>Ground<br>D D D<br>E E E 120V<br>F F F<br>Neutral<br>H<br> <br> <br>**----- End of picture text -----**<br>
## L LA400 A400: Blank insert
Blank to replace switch in single voltage models
## L LA6O1 A601: Insulating Boot
Plastic shroud to cover back of module to prevent inadvertent access
## R Replacement eplacement F Fuse use H Holders olders
L LA200 A200: North American Fuseholder
Accommodates one .25 x 1.25” fuse
## LA201: Metric Fuseholder LA201
Accommodates one 5 x 20mm metric fuse
177
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Dual Configuration Power Entry Module** _(continued)_
## L Series
**==> picture [490 x 377] intentionally omitted <==**
**----- Start of picture text -----**<br>
Case Styles<br>Flange Models, Non-filtered Snap-in Models, Non-filtered<br>3 4 A C E<br>1 2 B D F<br>G H<br>C D G H<br>C D<br>F<br>F<br>mb AB u .221 5.61 b E A UE .221 5.61 E<br>bay Bb) if B<br> <br> <br> <br> <br> <br>Flange Models, Filtered Snap-in Models, Filtered<br>3 4 A C E<br>1 2 B D F<br>C D G H G H<br>C D<br>F<br>F<br>AB .221 5.61 E A .221 5.61 E<br>te WFC es ee) LIC<br> <br>P SB Ese<br> <br> <br> <br> <br>**----- End of picture text -----**<br>
## Case Dimensions
||A|B|C|D|E|F|
|---|---|---|---|---|---|---|
|Model No.||<br>__|||||
|Flange|****|****|****|****|****|****|
|Unfiltered|__|__|__|__|__|__|
|Snap-in|****|__|****|****|****|****|
|Unfiltered|__||__|__|__|__|
|Flange|****|****|****|****|****|****|
|Filtered|__|__|__|__|__|__|
|Snap-in|****|__|****|****|****|****|
|Filtered|__||__|__|__|__|
178
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Dual Configuration Power Entry Module** _(continued)_
## L Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [28 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
6EDL<br>**----- End of picture text -----**<br>
**==> picture [417 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
2EDL 4EDL 6EDL<br>db db db<br>100908070 |eae|i 100908070 ||||||| 100908070 |ii<br>60 EE ie 60 || 60 CCIE<br>50 aa 50 a 50 CIE Cl<br>40 ee 40 oe, 40 |<br>30 [Ti IE 30 alll 30 alll —<br>20 _ = Ce 20 | oae anil 20 Ty<br>10 | 10 a 10 =<br>0 0.1 1 10 30 Cori Coir J 0 0.1 1 10 30 LOO Col 0 0.1 1 10 30 “<br>Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## 6EHL
**==> picture [115 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
db<br>1009080 |EE<br>70 IE i<br>6050 EEie<br>403020 Ceanl<br>10 _——<br>0<br>0.1 1 10 30<br>Frequency in MHz<br>**----- End of picture text -----**<br>
~~—~~ Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
|** **||** **|** **|** **|** **|||** **|||** **|** **|** **|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****||****|****||****|****|****|****|****|
|** **||||||||** **||||||||
|||||||||||||||||
|||||||||||||||||
|||||||||||||||||
|** **||||||||** **||||||||
|||||||||||||||||
179
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Power Entry Module with Enhanced EMI Filtering**
## LA Series
## UL Recognized CSA Certified
## L LA A S Series eries
- Power entry module with extended and enhanced low frequency filters
- North American or dual metric fuse holder options
- DPST on/off switch
- 120/240V voltage selection
- The F version provides basic performance two element circuit filter
- The X version provides a three element differential mode circuit with extended EMI attenuation, suitable for meeting FCC Part 15J, Class B conducted emissions limits
- The Z version provides a three element differential mode circuit with enhanced EMI low frequency attenuation, suitable for meeting EN55022 Level B as well as FCC Part 15J limits
## S Specifications pecifications
Maximum leakage current each Line to Ground:
|||XLA or|
|---|---|---|
|@120 VAC 60 Hz:<br>@250 VAC 50 Hz:|FLA Model<br>.25 mA<br>.50 mA|ZLA Model<br>.30 mA<br>.50 mA|
|Hipot rating (one minute):|||
|Line to Ground:||2250 VDC|
|Line to Line:||1450 VDC|
|Rated Voltage (max.):||250 VAC|
|Operating Frequency:||50/60 Hz|
|Rated Current:||3 to 5A|
|Required Fuse(s):|one .25 x 1.25”_(not included)_<br>or two 5 x 20mm_(not included)_||
|Switch:||DPST|
|10,000 operations at 51A max. inrush|10,000 operations at 51A max. inrush||
## O Ordering rdering I Information nformation
## 5 E F LA 2S
~~L~~ Case Case Style Style 2S - IEC inlet*, selectable fuse holder, DPST switch, spade terminals L LA A S Series eries F Filter ilter T Type ype F – General purpose X – High performance Z – Premium performance
## A Available vailable P Part art N Numbers umbers
~~Te~~ 5EFLA2S 3EXLA2S ~~I~~ 3EZLA2S
> L Leakage eakage c current urrent d designation esignation E – Low Leakage _(<0.5 mA)_ C Current urrent R Rating ating 3A or 5A
_*IEC 60320-1 C14 inlet mates with C13 connector_
180
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Power Entry Module with Enhanced EMI Filtering** _(continued)_
## LA Series
## V Voltage oltage S Selection election
To change selected voltage: remove the fuse cartridge using a small blade screwdriver or similar tool; select the desired voltage by matching the arrow on the fuse cartridge to the arrow located on the front of the unit (lower right corner); replace the fuse cartridge making sure the voltage selection arrow aligns with the arrow located on the front of the unit.
## C Changing hanging F Fuses uses
Remove the fuse cartridge using a small blade screwdriver or similar tool; for Metric fusing pull out the sliding fuse covers located at the top of each fuse compartment; insert desired fuses; push the sliding fuse covers back in place and insert the fuse cartridge back into the unit making sure the voltage selection arrow aligns with the arrow located on the front of the unit. (Note: Single North American or Metric fuse placement is always on the side of the desired voltage selection arrow behind the fuse symbol; the other compartment may be used as a spare or be left blank. Dual Metric fusing capability is available for 220/240 volts only.)
## E Electrical lectrical S Schematics chematics
## C Case ase S Styles tyles
**==> picture [240 x 154] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>F<br>B<br>° * C ° \° | D<br>Ct B oo C<br>A<br>D [E] F<br>I | / |<br>E<br><br> <br> <br> <br> <br>**----- End of picture text -----**<br>
## ~~CaseDimensions~~ Case Dimensions
|~~CaseDimensions~~|A|B|C|D|E|F|
|---|---|---|---|---|---|---|
|Part No.||<br>__|||||
|5EFLA2S<br>3EXLA2S|****<br>__<br>****|****<br>__<br>****|****<br>__<br>****|****<br>__<br>****|****<br>__<br>****|****<br>__<br>****|
||__|__|__|__|__|__|
|3EZLA2S|****|****|****|****|****|****|
||__|__|__|__|__|__|
## FLA Model
**==> picture [194 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
120V 240V A or D<br>Power on/off A A<br>120V<br>B B<br>Neutral ool Se can<br>C<br>Ground<br>- D a D<br>E E<br>120V<br>F F<br>Phase c oe f dd a<br>G<br>Customer<br>Transformer<br>Primaries<br>**----- End of picture text -----**<br>
## XLA & ZLA Model
**==> picture [200 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
120V 240V A or D<br>On/Off A A<br>120V<br>B B<br>Neutral<br>C<br>| }<br>D D<br>E E<br>120V<br>F F<br>Hot<br>G<br>c o Customer<br>Transformer<br>Primaries<br>**----- End of picture text -----**<br>
## Recommended Panel Cutout Recommended Panel Cutout
**==> picture [143 x 136] intentionally omitted <==**
**----- Start of picture text -----**<br>
.093<br>R<br>2.36<br>Ne —;<br>2.42*<br>61.47<br>.140 _ Dia.<br>3.56<br>al | | |<br>1.19*<br>~~ 30.23 * +.020 - .00<br>+ 0.5 - .00<br>1.57<br>39.88<br>**----- End of picture text -----**<br>
181
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Power Entry Module with Enhanced EMI Filtering** _(continued)_
## LA Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [417 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
5EFLA2S 3EXLA2S 3EZLA2S<br>db db db<br>100 100 100<br>90 CO Co 90 Satis 90 aT |<br>80 eIir 80 80<br>605070 |aa 605070 | 605070<br>40 El 40 | 40<br>30 30 30<br>20 20 20<br>10 10 10<br>0 Eeia HE 0 2Ett 0 |<br>0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
||||** **|** **|** **|** **||||||||** **|** **|** **|** **||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****||****|****|||||****|****|****|****|****|
| |||||||||| |||||||||||
| |||||||||| |||||||||||
| |||||||||| |||||||||||
182
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Slim Power Entry Module Family with Multiple Options**
## M Series
UL Recognized CSA Certified VDE Approved
**==> picture [139 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
XM / ZM<br>VM<br>**----- End of picture text -----**<br>
## O Ordering rdering I Information nformation
5 E F M 4 S C
Le M Mounting ounting Type Type C– Snap-In Omit for flange mount
> S Switch witch O Option ption S – DPST on/off switch Omit for none
V Voltage oltage S Selection election P Positions ositions 1 or 4
## M M S Series eries
## F Filter ilter T Type ype F – General purpose
H – Medical
X – High performance
Z – Premium performance V – Non-filtered
> L Leakage eakage c current urrent d designation esignation E – Low leakage _(<0.5 mA)_
_(Filtered models only)_
C Current urrent R Rating ating @ @120 120 V VAC AC 3, 5 or 6A
## M Seriesriesiesess M Seriesriesiesess Series eriesriesiesess
## M Seriesriesiesess
- Family of slim power entry modules that consume minimal depth behind panel
- Four compact modules each provide a different option combination
- Available non-filtered or with one of four filter circuits designed to meet a wide variety of applications
- Optional voltage selector configured for either 2 or 4 voltage selection
- Optional DPST on/off switch
- Included fuseholder accepts either single 3AG fuse or dual metric fuses
- Snap-in or flange mounting styles
## . F Filter ilter T Types ypes
H Models provide a basic performance dual element circuit EMI filter with minimal leakage current, suitable for medical applications, with attenuation similar to the EAH Series power inIet filter.
F Models provide a basic performance dual element circuit EMI filter, with attenuation similar to the EEA Series Power Inlet Filter.
X Models provide a high performance three element differential circuit filter, with extended EMI attenuation similar to the X Series chassis filter, suitable for bringing most digital equipment (including switching power supplies) into compliance with FCC Part 15J, Class B conducted emissions limits.
Z Models provide a premium performance three element differential circuit filter, with enhanced EMI low frequency attenuation similar to the P Series Z models, suitable for bringing most digital equipment (including switching power supplies) into compliance with EN55022 Level B as well as FCC Part 15J. For minimum panel footprint, see the P series on page 192.
183
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Slim Power Entry Module Family with Multiple Options** _(continued)_
## M Series
## S Specifications pecifications
Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: 2 ~~rr~~ HMA .25 mAFM XM/ZM.30 mA @250 VAC 50 Hz: 5 A .50 mA .50 mA Hipot rating (one minute): Line to Ground: 2250 VDC Line to Line: 1450 VDC Line to Load (switch off) non-filtered: 2500 VAC Rated Voltage (max.): 250VAC Operating Frequency: 50/60 Hz Rated Current @ 120 VAC: 3 to 6A Rated Current @ 250 VAC: 3A models: 2A 5A models: 4A 6A Switched models: 5A 6A non-switched models: 6A
Required Fuse(s): Reversible fuseholder accepts one .25 x 1.25” (not included) or two 5 x 20mm (not included)
Switch: DPST 100,000 operations at 70A max. inrush
## Accessories Accessories
> G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord
M MA100 A100: Power interconnect assembly For voltage select models. 8.5” wire leads
M MAIO1 A101: Plug only
M MAI02 A102: Strip of 100 pins for use with MA101 M MAI04 A104: Individual pins for use with MA101
> M MA302 A302: Two Voltage Selection Card
Marked 120V/240V. One card comes standard with every 2 voltage M series module
> M MA304 A304: Four Voltage Selection Card
Marked 100V/120V/230V/240V. One card comes standard with every 4 voltage M series module
## A Available vailable P Part art N Numbers umbers
**==> picture [414 x 241] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|Non-Filtered Models|(|
|SelectionsVoltage|Flange Mount|Snap-In|
|1|6VM1|6VM1S|6VM1C|6VM1SC|
|cs|A|
|2|6VM2|6VM2S|
|4|6VM4|6VM4S|6VM4C|6VM4SC|[1|1|0|0|O|
|General Purpose Filters|
|1|5EFM1|5EFM1S|5EFM1C|5EFM1SC|
|MA400: Medical safety bracket assemblyA400: Medical safety bracket assembly400: Medical safety bracket assembly00: Medical safety bracket assembly0: Medical safety bracket assembly: Medical safety bracket assembly|
|4|5EFM4|5EFM4S|5EFM4C|5EFM4SC|
|Prevents inadvertent removal of fuse(s)|
|Medical Filters|
|1|5EHM1|5EHM1S|
|4|5EHM4|5EHM4S|
|—f—}-—|Bee|
|High Performance - FCC-B|
|&//O|
|1|3EXM1S|
|4|3EXM4|3EXM4S|MA401: Bracket only|ee}|
|Premium Performance - EN55022-B|M|MA402|A402: Standoff only|
|1|3EZM1S|
|4|3EZM4|3EZM4S|
**----- End of picture text -----**<br>
MA400: Medical safety bracket assemblyA400: Medical safety bracket assembly400: Medical safety bracket assembly00: Medical safety bracket assembly0: Medical safety bracket assembly: Medical safety bracket assembly
Prevents inadvertent removal of fuse(s)
184
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Slim Power Entry Module Family with Multiple Options** _(continued)_
## M Series
A Accessories ccessories _(continued)_ MA601 ~~-~~ 604: Insulating Boot MA6O1 - 604 Plastic shroud for back of M series to prevent inadvertent access to connections
## F Fuse use I Installation nstallation I Instructions nstructions
1. Remove power cord
2. Insert a pocket screwdriver at point “X” as shown
MA601: Fits M4S versions MA6O1 MA602: Fits M1S versions MA603: Fits M4 versions **MA** G6O2603 MA604: First M1 versions MA604
## V Voltage oltage S Selection election
1. Open cover, using small blade screwdriver or similar tool _(see illustration on right)_
**==> picture [172 x 63] intentionally omitted <==**
**----- Start of picture text -----**<br>
— _ A —<br>USE ONLY WITH<br>250V FUSES<br>BEFORE REPLACING FUSESDISCONNECT POWER<br>ef ° GlceZ 2° Galam<br>“X”<br>A Section A-A<br>= ‘<br>**----- End of picture text -----**<br>
3. Gently lift the entire door UP approximately 1/4" _(minimum)_ Once lifted, the door will pivot on it’s hinges to expose the fuse holder
**==> picture [22 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lift Up<br>**----- End of picture text -----**<br>
2. Set aside cover/fuse block assembly
3. Pull voltage selector card straight out of housing, using indicator pin
4. When the fuse holder is installed in the single fuse position, apply the screwdriver as shown and gently lift up Use screwdriver as shown, do not use fingers
4. Orient selector card so that desired voltage is readable at the bottom
**==> picture [51 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
NOT here<br>Insert Here<br>**----- End of picture text -----**<br>
5. Orient indicator pin to point up when desired voltage is readable at bottom _(note that when indicator pin is fixed, successive voltages are selected by rotating the card 90° clockwise)_
6. Insert voltage selector card into housing, printed side of card facing forward toward IEC connector and edge containing the desired voltage first
_When the fuse holder is installed in the dual fuse position, it will normally release as soon as the door is opened_
7. Replace cover, and verify that indicator pin shows the desired voltage
5. Install one (1) AG fuse or two (2) metric fuses (see below)
6. Replace fuse holder into housing
7. Swing and push to snap door back in place
**==> picture [417 x 157] intentionally omitted <==**
**----- Start of picture text -----**<br>
Wiese 2 5 = P zs .<br>Fuse Options<br>[fp] Fuse Options<br>1 0 0 1 2 0<br>ri e n, [2]<br>Boa = |e= yeh e ee<br>100V 120V<br>oo \ U y a Vea \ c<br>0 0<br>North American Metric<br>“Rran D 4 Shr 0 RBe single fuse installation c o y dual fuse installation LAN<br>iN) =| = Pe<br>2 3 0 2 4 0 Install fuses on one side only, do not install<br>230V 240V both AG and metric fuses at the same time<br>2 0 1 0<br>4 2 0 3<br>0 1 0 2<br>1 0 2 0<br>2 4 3 0<br>0 2 0 1<br>3 2 4 2<br>1<br>**----- End of picture text -----**<br>
185
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Slim Power Entry Module Family with Multiple Options** _(continued)_
## M Series
## Electrical Schematics
## Non-Filtered Models
## VM1
**==> picture [229 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power On/Off<br>Note 3<br>Neutral<br>K K<br>Note 2<br>120V<br>L L<br>Hot G Customer<br>Transformer Primaries<br>**----- End of picture text -----**<br>
## Filtered Models
## FM1 & HM1
**==> picture [179 x 85] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power On/Off<br>Note 2<br>H B<br>Neutral<br>Note 1<br>Note 3<br>Phase J F<br>G<br>**----- End of picture text -----**<br>
## VM2
## FM4 & HM4
**==> picture [494 x 401] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power On/Off 120V 240V 120V 230V<br>Note 3 A 120V A 100V 240V<br>Neutral K H B B 120V Power On/Off A A 20V0VV<br>Note 2 Note 1 Neutral Note 2 K H B 100V<br>C C Note 1 Note 4<br>D D C C<br>120V Note 3<br>D D<br>E E 120V<br>Hot L Note 1 J FG F CustomerF Note 4 Phase L J EFF EFF 120V<br>Transformer Primaries Note 4 G Customer<br>Transformer Primaries<br>VM4 XM1 & ZM1<br>Power On/Off 100V120V 230V240V Power On/Off<br>Note 3 A A 20V Neutral Note 2 H B<br>100V Note 1<br>Neutral K H B<br>Note 2 Note 1<br>C C<br>D D<br>J F<br>E E 120V<br>Hot L J F F Phase<br>Note 1 G Customer G<br>j g Transformer Primaries Ap e D e<br>XM4 & ZM4<br> 120V 230V<br>100V 240V<br> Power On/Off A A 20V<br> Neutral Note 2 K Note 4 H B 100V<br> Note 1<br> C C<br> D D<br>E E<br>Phase L J F F 120V<br>Note 4<br>G Customer<br>Transformer Primaries<br> <br> <br> <br> <br> <br>**----- End of picture text -----**<br>
**==> picture [241 x 88] intentionally omitted <==**
**----- Start of picture text -----**<br>
120V 230V<br>100V 240V<br>Power On/Off A A 20V0VV<br>Neutral Note 2 K H B 100V<br>Note 1 Note 4<br>C C<br>Note 3<br>D D<br>Phase L J EFF EFF 120V<br>Note 4<br>G Customer<br>Transformer Primaries<br>**----- End of picture text -----**<br>
186
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Slim Power Entry Module Family with Multiple Options** _(continued)_
## M Series
**==> picture [492 x 589] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Ease ase S Styles tyles - - N Non- on f - fi iltered ltered M Models odels<br>6VM1 6VM2 & 6VM4<br>USE ONLY WITH250V FUSES C USE ONLY WITH250V FUSES 100V120V230V C<br>DISCONNECT POWER DISCONNECT POWER 240V<br>BEFORE REPLACING FUSES BEFORE REPLACING FUSES<br>(o e I LE | o y T ie<br>D E D E<br>B B<br>A A<br>ES ) -4 | ES]<br> <br> <br> <br> <br> <br>6VM1C 6VM4C<br>100V<br>BEFORE REPLACING FUSESUSE ONLY WITHDISCONNECT POWER250V FUSES C BEFORE REPLACING FUSESUSE ONLY WITHDISCONNECT POWER250V FUSES 240V120V230V C<br>D E D<br>E<br>i A s BEi i A BE<br> <br> <br> <br>6VM1S 6VM2S & 6VM4S<br>USE ONLY WITH250V FUSES C USE ONLY WITH250V FUSES 100V120V230V C<br>BEFORE REPLACING FUSESDISCONNECT POWER BEFORE REPLACING FUSESDISCONNECT POWER 240V<br>E<br>D D E<br>B<br>B<br>A<br>ial A<br> <br> <br> <br> <br> <br>6VM1SC 6VM4SC<br>100V<br>USE ONLY WITH USE ONLY WITH 120V<br>BEFORE REPLACING FUSESDISCONNECT POWER250V FUSES C BEFORE REPLACING FUSESDISCONNECT POWER250V FUSES 240V230V C<br>D E B E<br>-— A — Feh— | |asc) A —— i—e4<br> <br> <br> <br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
187
**te.com/help**
**corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Slim Power Entry Module Family with Multiple Options** _(continued)_
## M Series
**==> picture [493 x 529] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles - = F Filtered iltered M Models odels<br>3EXM1S & 3EZM1S 3EXM4S & 3EZM4S<br>G Threaded G Threaded<br>Insert Insert<br>-— — - -— —~ -<br>1.13* 1.17*<br>28.7 29.7<br>47.8 1.88* 78.49 3.09 Max. 47.8 1.88* 78.49 3.09 Max.<br>BEFORE REPLACING FUSESUSE ONLY WITHDISCONNECT POWER250V FUSES C BEFORE REPLACING FUSESUSE ONLY WITHDISCONNECT POWER250V FUSES 100V240V120V230V C<br>kL D E D E<br>B B<br>A *±.020 [ .508 ] A *±.020 [ .508 ]<br>—— an<br> <br> <br> <br> <br> <br> <br>3EXM4 & 3EZM4 5EHM1 & 5EFM1<br>G Threaded<br>Insert USE ONLY WITH250V FUSES C<br>1.13* BEFORE REPLACING FUSESDISCONNECT POWER<br>FA 28.7 7 | K F D E<br>r 47.8 1.88* = 78.49 3.09 Max. A B<br>BEFORE REPLACING FUSESUSE ONLY WITHDISCONNECT POWER250V FUSES 100V240V120V230V C<br>D<br>E<br>EE cL<br>B<br>A *±.020 [ .508 ]<br><br> <br> <br> <br><br>L_ d<br>**----- End of picture text -----**<br>
**==> picture [217 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
<br> <br> <br> <br> <br><br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
188
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Slim Power Entry Module Family with Multiple Options** _(continued)_
## M Series
**==> picture [483 x 598] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles - = F Filtered iltered M Models odels (continued)<br>5EFM1C 5EHM4 & 5EFM4<br>BEFORE REPLACING FUSESUSE ONLY WITHDISCONNECT POWER250V FUSES C BEFORE REPLACING FUSESUSE ONLY WITHDISCONNECT POWER250V FUSES 100V240V120V230V C<br>E<br>D E D<br>BE A ] ea B L<br>a, ee A t UP.<br> <br> <br> <br> <br><br>5EHM1S & 5EFM1S 5EFM4C<br>BEFORE REPLACING FUSESUSE ONLY WITHDISCONNECT POWER250V FUSES C BEFORE REPLACING FUSESUSE ONLY WITHDISCONNECT POWER250V FUSES 100V240V120V230V C<br>a D He E ‘ Ep<br>D E<br>B A<br>=e A — ae<br>a ° a |<br>iA<br><br> <br> <br> <br><br>5EFM1SC 5EHM4S & 5EFM4S<br>BEFORE REPLACING FUSESUSE ONLY WITHDISCONNECT POWER250V FUSES C BEFORE REPLACING FUSESUSE ONLY WITHDISCONNECT POWER250V FUSES 100V240V120V230V C<br>i e L<br>D E D E<br>A B<br>Ee, | f= “ Do<br>A<br><br> <br> <br> <br><br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
189
For email, phone or live chat, please go to **te.com/help**
**corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**Slim Power Entry Module Family with Multiple Options** _(continued)_
## M Series
**==> picture [224 x 200] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles - = F Filtered iltered M Models odels (continued)<br>5EFM4SC<br>— BEFORE REPLACING FUSESUSE ONLY WITHDISCONNECT POWER250V FUSESUSE ONLY WITHDISCONNECT POWER250V FUSESDISCONNECT POWER250V FUSES250V FUSES 100V240V120V230V240V120V230V120V230V230V =) C S<br>(ole<br>3] y|| FEII<br>D E<br>i AD i<br><br> <br> <br>**----- End of picture text -----**<br>
## C Case ase D Dimensions imensions
**==> picture [488 x 526] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|A|B|C|D|E|F|G|
|=)|S|Part No.||||—||||||
|—|BEFORE REPLACING FUSESUSE ONLY WITHDISCONNECT POWER250V FUSESUSE ONLY WITHDISCONNECT POWER250V FUSESDISCONNECT POWER250V FUSES250V FUSES|100V240V120V230V240V120V230V120V230V230V|C|6VM1||||||||
|(ole|||||||
|3]|y|||FEII|
|i|AD|i|E|6VM1C||||||||
||||||
|||||||
|6VM1S||
|||||||
||||||
|6VM1SC|||
||||||
|6VM2||||||||
|6VM4|||||||
||
|||6VM4C||||||||
||||||||||
|6VM2S||||||||
|6VM4S||||||
|6VM4SC||||||||
||||||
|R|Recommended|ecommended P|Panel|anel C|Cutouts|utouts|3EXM1S||||||||
|3EZM1S||||||||
|3EXM4||||||||
|3EZM4||||||||
|Insert on XM and ZM|.170|
|models only|Dia.|>|4.32|3EXM4S||||||||
|4S Models|1.17*|1.88*|3EZM4S|||||||
|1S & 4 models|29.7|1.13*|47.8|5EHM1||||||||
|28.7|5EFM1|||||||
|0.13|R|
|3.30|.570|14.5|5EFM1C||||||||
|1.145||||||
|.170|29.08|
|Dia.|4.32|5EHM1S||||||||
|5EFM1S|||||||
|4.45|.175|F|*± .020 [|.508|]|5EFM1SC||||||||
||||||
|B|
|5EHM4||||||||
|||5EFM4|||||||
||
||5EFM4C||||||||
||
||||||
||||
|5EHM4S||||||||
|5EFM4S||||||
|5EFM4SC||||||||
||||||
**----- End of picture text -----**<br>
190
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Slim Power Entry Module Family with Multiple Options** _(continued)_
## M Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [493 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
5EHM 5EFM 3EXM 3EZM<br>db db db db<br>10090 EE 10090 | 10090 | 10090<br>8070 CoECoE Cie 8070 || 8070 ||| 8070<br>60 | Cie 60 || 60 |Cy |a 60 CE<br>50 CoE 50 50 50 _|<br>40 CoE CieCie 40 |a 40 LAee: 40 ——on<br>30 30 30 30<br>20 oe 20 ete 20 Lert _ 20 6<br>10 10 10 10<br>0 0 0 0<br>0.1 1 10 30.15 0.1 1 10 30.15 0.1 1 10 30 0.1 1 10 30<br>eure Frequency in MHz «GRAFH Frequency in MHz © ERHRFHAREH Frequency in MHz © ERHISHIFH Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
||||** **|** **|** **|** **||||||||** **|** **|** **|** **||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****||****|****|||||****|****|****|****|****|
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
191
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Versatile Power Entry Module with Small Footprint**
## P Series
## ® UL Recognized CSA Certified VDE Approved WG
**==> picture [202 x 20] intentionally omitted <==**
**----- Start of picture text -----**<br>
PE filtered<br>PS non-filtered PS filtered<br>**----- End of picture text -----**<br>
## P P S Series eries
The P series CHAMELEON power entry module offers the most popular features in a small footprint design As the first 10A module to provide all five power entry functions in one compact design, the chameleon module readily adapts to its environment and the needs of international markets.
- Snap-in or flange mounting
- Standard IEC 60321-1 C14 power inlet
- Both North American and metric fusing capabilities
- Two voltage selection options (for 4-voltage selection, see the M, L or LA Series)
- Optional DPST on/off switch
- Filter options for general purpose, medical and high-performance EMI filtering
The CHAMELEON module’s compact design and modular construction allows selection of the required power entry feature — without altering the panel cutout. And the CHAMELEON module, with its optional adapters, will fit several common panel cutouts.
## . F Filter ilter T Types ypes
The CHAMELEON module has four filter and one non-filtered option:
S S m models odels provide an extended performance two element circuit EMI filter, with attenuation similar to the EEB Series power inlet filter. It offers protection for general purpose applications with stray Line to Ground and Line to Line noise that must be attenuated at the power inlet. These filters have limited leakage current and are available in current ratings of 3, 6 and 10A.
L L m models odels feature a high performance medical filter designed to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC part 15J, Class B) conducted emissions limits. They are available with current ratings of 6 and 10A. These high performance versions are only available with mounting ears, single voltage selection, in a complete RFI shield with options for switch, fuses and current ratings. Mounting extenders are not compatible with the L or Z models.
Z Z m models odels provide a high performance three element differential mode circuit filter, with extended EMI attenuation similar to the M Series Z models, to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emissions limits. They are available with current ratings of 6 and 10A. These high performance versions are only available with mounting ears, single voltage selection, in a complete RFI shield with options for switch, fuses and current ratings. Mounting extenders are not compatible with the L or Z models. For minimum depth behind the panel, see the M Series
> B m models odels are non-filtered and incorporate an interconnection block. The block connects the voltage selection terminals of an unfiltered CHAMELEON module with an IEC connector and an optional switch to reduce external wiring. Compatible with the A or B RFI shield options.
H H m models odels provide susceptibility protection with minimal leakage current, and are suitable for patient care and non-patient care medical equipment.
192
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Versatile Power Entry Module with Small Footprint** _(continued)_
## P Series
## O Ordering rdering I Information nformation
Part numbers are constructed by selecting the alphanumeric character which represents the desired feature. Note: For any option where shown as “0” use the digit ZERO (0) not the letter (O).
**==> picture [427 x 262] intentionally omitted <==**
**----- Start of picture text -----**<br>
Mounting Extender Switch Voltage Fuse Filter Filter Shield<br>Style Options1 Options* Select2 Options Type Current Options1<br>P S J 0 X S S 6 0<br>Mounting Style Switch Option Fuse Options Filter Current<br>E = Mounting ears 0 = Blank D = Dual fuse 0 = No filter<br>(Horizontal axis) S = Double pole S = Single fuse 3 = 3A<br>S = Snap-in single throw 6 = 6A<br>M = Mounting ears (DPST) X = 10A<br>(Vertical axis)<br>Extender Input Voltage Select Filter Type Shield Options<br>Option 0 = Single voltage 0 = No filter 0 = No shield<br>0 = None S = Dual voltage2 B = Interconnection A = Filter shield<br>C = FN260 select (SMPS) block3 B = Complete<br>J = J Series X = Dual voltage2 H = Medical Filter Shield<br>L = L Series1 select (series/parallel) L = High Performance C = Complete can<br> Medical [4] (for L & Z models)<br>S = General purpose<br>Z = High Performance [4]<br>**----- End of picture text -----**<br>
**==> picture [224 x 193] intentionally omitted <==**
**----- Start of picture text -----**<br>
Extender for<br>J-Series or others<br>Fuse holder<br>~ |<br>DS |<br>i=<br>Optional switch<br>—————— — P =<br>S e)<br>Optional filter<br>**----- End of picture text -----**<br>
## Notes:
- 1 L Series extender cannot be added to units with a shield. No style of extender can be added to units with B or C shields.
- 2 Dual voltage options are not available with L or Z Filter Types
- 3 When using the interconnection block, the last 3 digits of the part number are BX (0, A, or B)
- 4 High performance versions (L or Z filter types) are available with any switch or fuse option but only in 6 or 10A with horizontal (PE) or vertical (PM) mounting ears, single voltage (0), complete shield (C) and no extenders
- For alternative switch orientation options, please contact technical support or your Corcom product sales representative
The part number PS0SXSS6B would represent:
P Series (P) with a snap-in mount (S) with no extender (0) a switch (S) dual voltage select (X) single fusing (S) general purpose filter (S) for 6A (6) with a B shield (B)
193
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Versatile Power Entry Module with Small Footprint** _(continued)_
## P Series
## V Voltage oltage S Selection election
P series power entry modules include the voltage selector integral with the fuse holder. Three voltage selection options are each supported by one of three different fuse holders. The fifth digit of the part number specifies which of the three fuse holders is included to provide the desired voltage selection. The single voltage fuse holder (option “0”) has no voltage indication markings. The dual voltage options select 115V or 230V by removing the fuse holder, flipping it over, and reinstalling it. Voltage selection is indicated through a window in the P Series door. The “SMPS” fuse holder (option “S”) jumpers two independent P Series terminals to indicate 230V operation to a switching mode power supply. The “PRSR” parallel/serial fuse holder (option “X”) connects the windings of the equipment’s dual primary transformer (not included) to step down the voltage or double up the current. The markings on the voltage selection fuse holders also remind the user to install the appropriate fuse for the current at the selected voltage.
## S Shield hield Oield Oeld Old Od O O Options ptionstionsionsonsnss
## S Shield hield Oield Oeld Old Od O O Options ptionstionsionsonsnss
The P series offers several RF shield options. The metal shield, optional on S, H and B filtered models, provides shielding from radiated emissions and provides an RF ground for the filter to the panel. This shield is available in two versions; a shield of the filter components (designated by an A as the final digit) and a complete shield (designated by B as the final digit).
The A shield covers the filter portion of the module and increases performance of the filter by protecting the components from RFI coupling. This shield allows the use of the C or J extender.
The B shield covers the entire power entry module with metal, protecting the filter from RFI coupling, and covering the mounting cut-out to block RFI entering or leaving the equipment. The B shield cannot be used with any extender.
A complete metal enclosure is integral to both the high performance L and Z models, and must be specified by a C in the part number’s final digit. This option is only available with the L or Z models.
## I Input nput V Voltage oltage S Selection election S Schemes chemes
## S - “SPMS” Jumper Type
**==> picture [241 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
115V 230V<br>Power on/off<br>Hot G A Power<br>p Note 1 et Note 1 en e M B eg input 7 |<br>Ground Sel.<br>Note 1 Note 1 C Jumpers<br>Neutral H D<br>SMPS<br>Provision for<br>single fusing<br>**----- End of picture text -----**<br>
## X - “PRSR” Parallel / Serial Type for Dual Primary Transformer
**==> picture [241 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
115V 230V<br>Power on/off<br>Hot G A<br>P Note 1 H Note 2 B - on 115V |<br>Ground<br>C<br>Note 1 Note 2 115V<br>Neutral H D<br>py m a Transformer a 5<br>Provision for primary<br>single fusing<br>**----- End of picture text -----**<br>
**==> picture [162 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
“A” Shield<br>“B” Shield<br>**----- End of picture text -----**<br>
-
-
194
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Versatile Power Entry Module with Small Footprint** _(continued)_
## P Series
## F Fuseholder useholder
Another feature of the P series power entry module is the versatile fusing arrangement. The fuse holder can hold two 1/4” x 1-1/4” (3AG) or 5 x 20mm (metric) fuses. Single fusing is supported with a conversion clip that shorts one of the two fuse positions, and is designated by an S in the sixth part number digit. A module designated for a single fuse may be reconfigured by the manufacturer or the user to accept two fuses by simply removing the shorting clip. For applications intended for dual fusing, specify a D in the sixth part number digit.
**==> picture [55 x 20] intentionally omitted <==**
**----- Start of picture text -----**<br>
Conversion Clip for<br>Single Fuse<br>Applications<br>**----- End of picture text -----**<br>
## A Accessories ccessories
> G GA400 A400: NEMA 5-15P to IEC 60320-1 C-13 line cord
P PAI00 A100: Power interconnect assembly For voltage select models. Designed for use with either filtered or non-filtered units, 6” wire leads _—_—_eC
For voltage select models. Designed for use with
PA101: Plug only PAIOI PA102: Pins only for use with PA101 PAIO2 P PAIOS A105: Same as PA100 but with two wires for units with no voltage selection
## I Interconnection nterconnection B Block lock
Installation of the unfiltered versions of the P series requires wiring of the IEC socket terminals to the optional switch and the switch to the fuse holder. Labor can be eliminated by ordering the module with an interconnection block. This feature, designated by “BX” in the seventh and eighth digits, pre wires the module so that only connection to the equipment must be done during installation. The interconnection block includes a plastic case to prevent access to the internal connections.
The dimensions of this alternative are the same as the fi filtered ltered v versions. ersions. The dimensions of this alternative are the same as the
> P PA400 A400: J Extender
Extends P Series height to fit J panel cutout
P PA410 A410: L Extender
Extends P Series width to fit L panel cutout
> P PA420 A420: C Extender
Extends P Series height to fit C panel cutout
PA400
J Series Extender
_C & L Extenders can not be used with B Shields._
_L Extender can not be used with shields_
195
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Versatile Power Entry Module with Small Footprint** _(continued)_
## P Series
**==> picture [466 x 590] intentionally omitted <==**
**----- Start of picture text -----**<br>
S Specifications pecifications E Electrical lectrical S Schematics chematics<br>Maximum leakage current each Line to Ground: H Model<br>H & L Models S & Z Models LINE LOAD<br>@ 120 VAC 60 Hz: 2 A .25 mA<br>@ 250 VAC 50 Hz: 5 A .50 mA<br>Hipot rating (one minute):<br>Line to Ground: 2250 VDC<br>Line to Line: 1450 VDC<br>Rated Voltage(max.): 250VAC S Model<br>Operating Voltages: LINE LOAD<br>Selectable or Fixed 115/230 VAC<br>Operating Frequency: 50/60 Hz<br>Rated Current: Non-Filtered – 10A<br>Filtered – 3, 6 or 10A<br>L Model<br>Fuseholder: Accepts one or two fuses LINE LOAD<br>.25 x 1.25”(not included)<br>or 5 x 20mm (not included)<br>Switch: DPST<br>10,000 operations at 51A max. inrush<br>Z Model<br>LINE LOAD<br>C Case ase S Styles tyles<br>Front View<br>PM PE PS<br>High Performance<br>Version Only<br>| = \ ff<br>— 2.496 | 2.88 2.39 —= 2.29 |<br>63.4 73.15 60.71 58.16<br>—— o) —<br>1.58 1.22<br>40.13 30.98<br>1.22 1.95<br>30.98 49.53<br><br> <br> <br>**----- End of picture text -----**<br>
196
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Versatile Power Entry Module with Small Footprint** _(continued)_
## P Series
## C Case ase S Styles tyles _(continued)_ Extender Options
**==> picture [366 x 72] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Extender - FN260 J Extender - J Series<br>2.51 2.72<br>63.75 69.08<br>- = es /T Fl iPES<br>Bottom edge Bottom edge<br>**----- End of picture text -----**<br>
## Standard Models - Side and Rear View
**==> picture [308 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Non-Filtered Filtered<br>**----- End of picture text -----**<br>
**==> picture [466 x 428] intentionally omitted <==**
**----- Start of picture text -----**<br>
Tro CP<br>2.29<br>58.16<br>—te— te ||<br>.225 1.93 2.13<br>5.715 Li 49.02 | L 54.10 t<br><br> <br> <br>High Performance Models - Side and Rear View<br>PM PE<br>| ON ———.<br>P| (fee) | ‘ee<br>55.12 - 2.17 60.71 — 2.39<br>1.12<br>3.93 28.45<br>1.23<br>99.82<br>31.24<br>4.42<br>a 112.27 A<br><br> <br> <br>**----- End of picture text -----**<br>
197
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Versatile Power Entry Module with Small Footprint** _(continued)_
## P Series
## Case Styles _(continued)_
## Shield Options
**==> picture [299 x 377] intentionally omitted <==**
**----- Start of picture text -----**<br>
“A” Shield “B” Shield<br>WV<br>2.19 2.19<br>re 55.63 55.63<br>Shields can only be used with filtered models. B shield may not be used with J or C extender<br> Panel Cutoutanel Cutoutnel Cutoutel Cutoutl Cutout Cutoututouttoutoututt<br>Cutout PM PE<br>“A”<br>2.496<br>“B”<br>63.40<br>.06 1.575<br>R<br>1.524 40.00<br>.135<br>Mounting Hole Diameter 3.43<br>**----- End of picture text -----**<br>
## _Note: Shields can only be used with filtered models. B shield may not be used with J or C extender_
## Recommended Panel Cutoutanel Cutoutnel Cutoutel Cutoutl Cutout Cutoututouttoutoututt
_Note: For snap-in applications, the “A” sides must have a .020 [.508] radius on the installation side. Dimensions are for front mount applications. Rear mount dimensions should be determined based on customer’s application parameters. Snap-in models allow for front mounting only. Not recommended for use in plastic panels._
|Style|Dimension “A”<br>+.008 - .000|Dimension “A”<br>+.008 - .000|Dimension “A”<br>+.008 - .000|Dimension “B”<br>+.008 - .000|Dimension “B”<br>+.008 - .000|
|---|---|---|---|---|---|
||No Shield|Shielded|High Performance|Standard|High Performance|
|PM<br>PE<br>PS<br>PSC<br>PSJ<br>PSL|1.06 [_26.92_]<br>1.12 [_28.45_]<br>1.06 [_26.92_]<br>1.06 [_26.92_]<br>1.06 [_26.92_]<br>1.12 [_28.45_]|1.12 [_28.45_]<br>1.12 [_28.45_]<br>1.12 [_28.45_]<br>1.12 [_28.45_]<br>1.12 [_28.45_]<br>-|1.12 [_28.45_]<br>1.15 [_29.21_]<br>-<br>-<br>-<br>-|2.13 [_54.10_]<br>2.201 [_55.91_]*<br>2.201 [_55.91_]*<br>2.52 [_64.01_]<br>2.60 [_66.04_]<br>2.201 [_55.91_]*|2.201 [_55.91_]<br>2.201 [_55.91_]<br>-<br>-<br>-<br>-|
_*For panel thickness of 0.031 - 0.079 [0.787 - 2.01] only. Use 2.213 [56.21] for panel thickness of 0.083 - 0.114 [2.0 - 2.90]_
198
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
**Versatile Power Entry Module with Small Footprint** _(continued)_
## P Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
Measured in closed 50 Ohm system
## S Models
**==> picture [408 x 244] intentionally omitted <==**
**----- Start of picture text -----**<br>
3A 6A 10A<br>db db db<br>100908070 |Coenn ,i 100908070 |aCAE ir A 100908070 ||CIE<br>60 AA 60 60 I A<br>50 [CTI 50 IAL 50 AY<br>40 eT 40 Ee. 40 =<br>30 eer AI A 30 CoeTAOAT 30 a,[eri<br>2010 re,[erm 2010 [eet HI 2010 en— ili<br>0 P= 0.1 1 10 30 ie Fii 0 0.1 1 10 30 L rc Ler Li | Tn i TIT 0 Cerri 0.1 1 10 30 eetoni —<br>Frequency in MHz Frequency in MHz Frequency in MHz<br>3A 6A 10A<br>db db db<br>100908070 | Cee i 100908070 aa 100908070 |a<br>60 Coe i 60 Coie 60 Coie i<br>50 Cee Ei 50 Ce i 50 a<br>40 a 40 [I TE 40 a<br>30 ee et 30 Le 30 oer<br>20 Pel a 20 Pe. al 20 ea<br>10 Cerri ti I 10 Seri | ir TI 10 rrr<br>0 0.1 1 10 30 a 0 0.1 1 10 30 a 0 0.1 1 10 30 Coe| ii<br>Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
3A
## H Models
3A
## L Models
**==> picture [259 x 252] intentionally omitted <==**
**----- Start of picture text -----**<br>
6A 10A<br>db db<br>10090 OO oI 10090 COL<br>80 | 80 Co oo<br>70 CO | 70 NT<br>60 CCCI a 60 ee<br>50 CO OIEATI C OINSe 50 LSCO 7 Co<br>4030 CACCO Fn 4030 COEZAI Co<br>20 OP TI 20 A<br>10 ae |,IE Cs 10 eeLa<br>0 0<br>0.01 0.1 1 10 30 0.01 0.1 1 10 30<br>Frequency in MHz Frequency in MHz<br>6A 10A<br>db db<br>10090 | 10090 COL<br>80 CCT ATT SS 80 2AOAL oo<br>6070 CIEny AZI Coe 6070 COENyZI ey<br>50 COZ 50 A<br>40 "a To| 40 CerriPB<br>30 ae 30 CI<br>IE Ce Par M00<br>20 FE Ce 20 CAT CI Co<br>10 CI CIE Coie 10 CO COI Co<br>0 0.01 0.1 1 10 30 COO COI Cooiir 0 0.01 0.1 1 10 30 CoonOI Coir 0<br>Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
## Z Models
199
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Versatile Power Entry Module with Small Footprint** _(continued)_
## P Series
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
|** **|||** **|** **|** **|** **|** **||||** **|||** **|** **|** **|** **|** **|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****|****||****||****|****|****|****|****|****|****|****|
|** **|||||||||||** **||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
|** **|||||||||||** **||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
|** **|||** **||** **||||||** **|||** **||** **|||||
|****|****||****|****|****|****|****|****|****||****|****||****|****|****|****|****|****|****|
|** **|||||||||||** **||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
|** **|||||||||||** **||||||||||
||||||||||||||||||||||
||||||||||||||||||||||
200
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Power Inlet Connectors**
## SR Series
## UL Recognized CSA Certified VDE Approved*
**==> picture [223 x 71] intentionally omitted <==**
**----- Start of picture text -----**<br>
20ESRMC2<br>20ESRM-3<br>6ESRMC2<br>6ESRM-3<br>**----- End of picture text -----**<br>
## S Specifications pecifications
## SR S Seriesriesiesess SR R S Seriesriesiesess Series eriesriesiesess
## SR S Seriesriesiesess
- Full Line of popular AC receptacles
Rated Voltage (max.): 250 VAC
- Male and female power line connectors
Materials:
- Snap-in and flange mount versions
Insulator: Thermoplastic UL 94V-0 flame rating Prongs: Solid brass, nickel plated Terminals: Brass, tin plated Temperature Rating: For “cold” connections, 65°C
- IEC60320-1 C-13 & C14 inlets rated up to 15A
- IEC60320-1 C-19 & C-20 inlets rated up to 20A
## O Ordering rdering I Information nformation
- 6 E SR M - P ~~L~~ R Rear ear C Connector onnector S Styles tyles 2 – .187 [ _4.8_ ] spade terminals 3 – .250 [ _6.3_ ] spade terminals P – PC board pins
## A ~~Available~~ vailable P ~~Part~~ art ~~Numbers~~ Numbers
|Type<br>~~Available Part~~|Male Connector<br>~~Part Numbers~~|Female Connector|
|---|---|---|
|PC Pins<br>Snap-In<br>Flange Mount<br>Snap-In<br>Flange Mount|6ESRM-P<br>6ESRMC2<br>6ESRM-3<br>20ESRMC2<br>20ESRM-3|6ESRFC3<br>6ESRF-3|
Fits .063 [ _1.6_ ] hole
- M Mounting ounting S Style tyle C – Snap-In
- Flange
- F Front ront C Connector onnector S Styles tyles M – Male
## C Case ase Styles Styles
## 6ESRM-P
_15A = IEC 60320-1 C-14 20A = IEC 60320-1 C-20_
**==> picture [413 x 185] intentionally omitted <==**
**----- Start of picture text -----**<br>
20A = IEC 60320-1 C-20 .343* 15.06 .593* .380<br>F – Female a 8.71 9.65<br>15A = IEC 60320-1 C-13<br>4(N\ ro .360<br>SR Series A B 18.26 .719 D 40.00 1.575 .360 9.14<br>L SR eE – Low Leakage a Series kage current de (<0.5 mA) signation ‘4 | — fat . fo 1.63 064 9.14 Dia.<br>Leakage current designation | io Sy [ | i 7<br>Current Rating Indicator C .125 3.17 .094 2.39 * 3.45 .136 Dia.<br>Pin Layout<br>Current 6 = 15A max.* Rating Indicator L_ _ rh E _<br>20 = 20A max.* 3.40 .134 — Dia. +0<br>TN 30.25 1.190* Cutout yt 40.00 1.575 4.78 .188 .094 2.39 * *+.005 -.000<br>+.127 -.000<br>i me \ a 7 _<br>.232 5.9 R .885*<br>_ 1 22.48 = to of<br>**----- End of picture text -----**<br>
- _*15A versions are VDE approved at 10A, 250VAC max. 20A versions are VDE approved at 16A, 250VAC max._
201
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Power Inlet Connectors** _(continued)_
## SR Series
## C Case ase S Styles tyles _(continued)_
**==> picture [60 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
6ESRMC2<br>**----- End of picture text -----**<br>
**==> picture [68 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
20ESRMC2<br>**----- End of picture text -----**<br>
**==> picture [490 x 542] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.079<br>A 27.4 Cutout .956<br>C Cutout 24.30<br>t k e) IE IB T L .<br>C .1259 3.2 .197 5.0 R .779 19.8 A .1259 3.2 .177 4.5 R 1.27<br>E 32.30<br>B<br>SE A SoH E] EF Le<br> <br> <br> <br>6ESRFC3 20ESRM-3<br>.134 3.4 Dia. .137 3.4 Dia.<br>1.272<br>im A 32.26 Cutout \ Lo — _ =0<br>A B 32.30 1.27 Cutout<br>i a C .102 2.6 .157 4.0 n R i 24.77 .975 Tf a a<br>pa | E | | .205 M .177 4.5 S R<br>C 5.2 .956<br> f E e 24.30<br> <br> <br> <br> <br>6ESRM-3<br>.134 3.4 Dia. .134 3.4 Dia.<br>A B D G Cutout<br>Case Dimensions<br>Sh im a<br>R A B C D E<br>C i a E H Part No. <br> <br> 6ESRM-P<br> <br> <br> 6ESRMC2 <br> <br> <br>6ESRFC3 <br>6ESRF-3 BE <br>Oo .134 3.4 Dia. .134 — 3.4 Dia. +6 6ESRM-3 <br> <br>A B 32.26 1.272 Cutout 6ESRF-3 <br> <br>.102 .256 6.5 R 20ESRMC2 <br>~ C ] 2.6 ~a12x 24.77 .976 <br>an E 20ESRM-3 <br> <br> <br> <br>**----- End of picture text -----**<br>
202
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Minimum Depth, Cost-effective Shielded Power Inlet Filter**
## SRB Series
UL Recognized CSA Certified VDE Approved*
**==> picture [190 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
SRBP<br>SRBS8<br>SRB1 SRB2<br>**----- End of picture text -----**<br>
## S SRB RB S Series eries
- Smallest depth Corcom RFI filter available
- Complete shield
- Wide range of capacitor values
- Attenuates coupled EMI up to 300MHz
- Minimal to low leakage current versions are suitable for patient and non-patient contact medical equipment.
- Full range of mounting and termination options including unique vertical and horizontal orientation slide in mounts eliminate the need for mounting hardware
## O Ordering rdering I Information nformation
15 SRB S 1 - Q
L C capacitor apacitor I ID D See Chart Omit if none
## O Output utput S Styles tyles
1 – Spade terminals _(back)_
2 – Spade terminals _(bottom)_ 8 – Wire leads P – PC board pins
> M Mounting ounting S Style tyle S – Snap-in X – Slide-in ( _short edge / horizontal)_ Y – Slide-in ( _long edge / vertical)_ Omit for flange mount
> S SRB RB S Series eries
C Current urrent R Rating ating 15A
- _*15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC_
## S Specifications pecifications
Maximum leakage current each Line to Ground:
|Capacitor ID / Value<br>Blank / None<br>Q / 33 pF<br>R / 100 pF<br>S / 220 pF<br>T / 330 pF<br>W / 470 pF|@120 VAC<br>60 Hz<br>2A<br>2.1A<br>9.6A<br>19.2A<br>24.0A<br>0.04 mA|@250 VAC<br>50 Hz<br>5A<br>3.65A<br>16.6A<br>33.2A<br>41.5A<br>0.07 mA|
|---|---|---|
|X / 1000 pF<br>Y / 2200 pF<br>Z / 3300 pF<br>Hipot rating (one minute):<br>Line to Ground:<br>Line to Line:<br>Rated Voltage (max.):<br>Operating Frequency:<br>Rated Current:|0.07 mA<br>0.16 mA<br>0.24 mA|0.13 mA<br>0.28 mA<br>0.42 mA<br>2250 VDC<br>1450 VDC<br>250 VAC<br>50/60 Hz<br>15A*|
Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir ~~~~ (85-Ta)/45
## C Capacitor apacitor O Options ptions
|Capacitor ID<br>Q<br>R<br>S|Capacitor Value<br>33 pF<br>100 pF<br>220 pF|
|---|---|
|T|330 pF|
|W<br>X|470 pF<br>1000 pF|
|Y*|2200 pF|
|Z*|3300 pF|
- _*Not available in SRB8, SRBX or SRBY styles_
203
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Minimum Depth, Cost-effective Shielded Power Inlet Filter** _(continued)_
## SRB Series
## A Available vailable P Part art N Numbers umbers
|15SRB1<br>15SRB1-Q<br>15SRB1-R<br>15SRB1-S<br>15SRB1-T<br>15SRB1-W<br>15SRB1-X<br>15SRB1-Y<br>15SRB1-Z|15SRB2<br>15SRB2-Q<br>15SRB2-R<br>15SRB2-S<br>15SRB2-T<br>15SRB2-W<br>15SRB2-X<br>15SRB2-Y<br>15SRB2-Z|15SRB2<br>15SRBP<br>15SRB2-Q<br>15SRBP-Q<br>15SRB2-R<br>15SRBP-R<br>15SRB2-S<br>15SRBP-S<br>15SRB2-T<br>15SRBP-T<br>15SRB2-W<br>15SRBP-W<br>15SRB2-X<br>15SRBP-X<br>15SRB2-Y<br>15SRBP-Y<br>15SRB2-Z<br>15SRBP-Z|15SRB8<br>15SRB8-Q<br>15SRB8-R<br>15SRB8-S<br>15SRB8-T<br>15SRB8-W<br>15SRB8-X|
|---|---|---|---|
|Snap-In||Slide-In||
|15SRBS1<br>15SRBS1-Q<br>15SRBS1-R<br>15SRBS1-S<br>15SRBS1-T<br>15SRBS1-W<br>15SRBS1-X<br>15SRBS1-Y<br>15SRBS1-Z|15SRBS8<br>15SRBS8-Q<br>15SRBS8-R<br>15SRBS8-S<br>15SRBS8-T<br>15SRBS8-W<br>15SRBS8-X|15SRBS8<br>15SRBX8<br>15SRBS8-Q<br>15SRBX8-Q<br>15SRBS8-R<br>15SRBX8-R<br>15SRBS8-S<br>15SRBX8-S<br>15SRBS8-T<br>15SRBX8-T<br>15SRBS8-W<br>15SRBX8-W<br>15SRBS8-X<br>15SRBX8-X|15SRBY8<br>15SRBY8-Q<br>15SRBY8-R<br>15SRBY8-S<br>15SRBY8-T<br>15SRBY8-W<br>15SRBY8-X|
**==> picture [198 x 70] intentionally omitted <==**
**----- Start of picture text -----**<br>
E Electrical lectrical S Schematic chematic<br>LINE LOAD<br>+<br>**----- End of picture text -----**<br>
## C Case ase S Styles tyles
## SRB1
**==> picture [235 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
C<br>ee 9 [| B cea:<br>D a A B<br>E<br><br> <br><br> <br> <br> <br>**----- End of picture text -----**<br>
## SRB2
**==> picture [216 x 122] intentionally omitted <==**
**----- Start of picture text -----**<br>
C<br>ee; [L_]<br>SS —) L___ {rt<br>on D | f A oi r e B y<br>E<br><br> <br><br> <br> <br> <br>**----- End of picture text -----**<br>
**==> picture [224 x 129] intentionally omitted <==**
**----- Start of picture text -----**<br>
SRBP<br>C<br>[|@ pi lo<br>D A B<br>T IT T T TT<br>T T)<br>E<br><br> <br><br> <br> <br>**----- End of picture text -----**<br>
SRBS1
> A Accessories ccessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
**==> picture [212 x 100] intentionally omitted <==**
**----- Start of picture text -----**<br>
C<br>f Ihe Y(e]<br>D<br>E A B<br> nnn<br> <br> <br> <br>**----- End of picture text -----**<br>
204
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Minimum Depth, Cost-effective Shielded Power Inlet Filter** _(continued)_
## SRB Series
**==> picture [485 x 203] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Case ase S Styles tyles (continued)<br>SRB8 SRBY8<br>.045 A<br>ai Blue \ | Blue<br>D E BrownGreen/Yellow B D E Grn/Yel B<br>Brown<br>@) 0 ) G C E Engage panel edge here et @<br>max. 24.39 0.96 C<br>= [-<br>L r <br> <br> <br><br> <br> <br>A<br>**----- End of picture text -----**<br>
SRBS8 C Case ase D Dimensions imensions | Blue Part No. A B C D E D E Green/Yellow B __ Brown ** ** 15SRB1 Gu ~~EET BJ}~~ _ _ ** ** 15SRB2 _ _ ** ** max. _24.39_ 0.96 a ~~ot,~~ C 15SRBP ~~BS~~ _ _ E ~~P —____—~~ ** ** 15SRBS1 _ _ ** ** __ 15SRB8 _ _ ** ** 15SRBS8 _ _ SRBX8 ** ** Blue 15SRBX8 _ _ Grn/Yel D E Brown B 15SRBY8 **** _ _ **** __ **** __ **** _ _ **** ll L ~~E:~~ SJ} ~~Pe~~ A
Blue Grn/Yel D E B Brown ll L ~~E:~~ SJ} ~~Pe~~ .045 ~~a~~ A i” C _ L Engage panel edge here __
205
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Minimum Depth, Cost-effective Shielded Power Inlet Filter** _(continued)_
## SRB Series
## R Recommended ecommended P Panel anel C Cutouts utouts
## P PC C B Board oard L Layout ayout
**==> picture [130 x 110] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.075<br>∅<br>1.91<br>a cae a 0.520 13.21<br>0.551<br>.685** 13.99<br>jy 17.40*<br>**----- End of picture text -----**<br>
## SRB1, SRB2, SRBP & SRB8
**==> picture [344 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
Front Mount Back Mount<br>Q 20.8 .820 — .900 22.9 — a<br>1.200 3.56 .140 ∅ 1.200 3.56 .140 ∅<br>30.48 30.48<br>1.575 1.575<br>40.01 _ .12 R. 40.01 .234 R.<br>3.05 Typ. 5.94 Typ. .685**<br>Tolerances ± .005 [ 0.13 ] unless otherwise noted _ jy 17.40*<br> *±.015 [ 0.38 ]<br> <br>**----- End of picture text -----**<br>
SRBS
G R _4.775_ 0.188 Max. 0.815 __ _20.70_ __ __ ~~TE~~ __ Tolerance ±.002 _[.050]_ SRBX
**==> picture [25 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
SRBX8<br>**----- End of picture text -----**<br>
**==> picture [19 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cover<br>**----- End of picture text -----**<br>
**==> picture [241 x 235] intentionally omitted <==**
**----- Start of picture text -----**<br>
.722 .836<br>18.34 21.23<br>min. min.<br>Jacket<br>Flange<br>AL T R t<br>ae<br>R 0.15 max. 1.066<br>3.81 27.07 Panel<br>± .005 [ .127 ] Thickness .039 [1.0] ± .005 [.127]<br>SRBY<br>Cover<br>1.05 1.15<br>26.67 29.21<br>min. min.<br>Jacket<br>yy [et<br>Flange<br>—<br>R 0.15 max. .741<br>3.81 18.82 Panel<br>± .005 [ .127 ] Thickness .039 [1.0] ± .005 [.127]<br>**----- End of picture text -----**<br>
206
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**3**
## **Minimum Depth, Cost-effective Shielded Power Inlet Filter** _(continued)_
## SRB Series
## P Performance erformance D Data ata
## Typical Insertion Loss
Measured in closed 50 Ohm system
**==> picture [493 x 246] intentionally omitted <==**
**----- Start of picture text -----**<br>
Q R S T<br>db db db db<br>40 40 40 40<br>35 a 35 _ TU Ti 35 _ TU Ti 35 LTT Ti<br>30 ee 30 a 30 a 30 |<br>25 a 25 a 25 a 25 ee<br>20 a 20 LT Ty 20 LIE PAN 20 oN<br>15 a 15 |e 15 ee 15 nin im.<br>10 10 10 10<br>5 5 5 5<br>CHT” a eet Feat<br>0 0 0 0<br>1 10 100 300 1 10 100 300 1 10 100 300 1 10 100 300<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>W X Y Z<br>db db db db<br>40 40 40 40<br>35 L TU TT 35 _ TT Ti 35 LT TTT 35 a<br>30 a 30 a 30 | 30 LTT TN<br>25 | 25 ee) 25 LTE ANTE 25 a,<br>20 20 20 20<br>15 CHIC 15 TIE ZATTINGG 15 CWC 15 HEH<br>10 10 10 10<br>HAE EEA eISSN = TET<br>5 LTA 5 a 5 rnin 5 LA<br>0 1 10 100 300 ert | TTT | 0 1 10 100 300 ert FTTH TI 0 1 10 100 300 A THE FTTH 0 1 10 100 300 4<br>Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz<br>**----- End of picture text -----**<br>
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
|** **|||** **|** **|** **||
|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|
||||||||
||||||||
||||||||
||||||||
||||||||
||||||||
||||||||
||||||||
207
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Engineering Notes**
208
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**4**
## **4. DC Filters — Table of Contents**
|I<br>n<br>t<br>r<br>o<br>d<br>u<br>c<br>t<br>i<br>o<br>n<br>INTPOGUCTION|.<br>.<br>.<br>.<br>.<br>2...|.<br>.<br>.<br>.<br>.<br>2...|.<br>.<br>.<br>.<br>.<br>2...|.<br>.<br>.<br>.<br>.<br>2...|.<br>.<br>.<br>.<br>.<br>2...|.<br>.<br>.<br>.<br> ccc|.<br>.<br>.<br>.<br> ccc|.<br>.<br>.<br>.<br> ccc|.<br>.<br>.<br>.<br> ccc|.<br>.<br>.<br>.<br>.<br> cece|.<br>.<br>.<br>.<br>.<br> cece|.<br>.<br>.<br>.<br>.<br> cece|.<br>.<br>.<br>.<br>.<br> cece|.<br>.<br>.<br>.<br>.<br>.<br>.<br> cece vv|.<br>.<br>.<br>.<br>.<br>.<br>.<br> cece vv|.<br>.<br>.<br>.<br>.<br>.<br>.<br> cece vv|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br> cece esses|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br> cece esses|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br> cece esses|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br> cece esses|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>1<br>0<br> sevvvvssscesssesvvvves<br>DIO|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>1<br>0<br> sevvvvssscesssesvvvves<br>DIO|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>1<br>0<br> sevvvvssscesssesvvvves<br>DIO|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>1<br>0<br> sevvvvssscesssesvvvves<br>DIO|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>1<br>0<br> sevvvvssscesssesvvvves<br>DIO|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>1<br>0<br> sevvvvssscesssesvvvves<br>DIO|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>1<br>0<br> sevvvvssscesssesvvvves<br>DIO|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>1<br>0<br> sevvvvssscesssesvvvves<br>DIO|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|S<br>e<br>l<br>e<br>c<br>t<br>o<br>r<br>C<br>h<br>a<br>r<br>t<br>.<br>Selector Chart|||.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>1<br>1<br>......0cccccccccccccvvvvvesecccssssvevvvssasseevvcvcdLll||||||||||||||||||||||||||
|DA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212|DA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212|DA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212|||||DA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212|||DA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212|||DA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212|DA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212|||DA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212||||DA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212|||||DA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212|||
|DB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214||||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214|||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214|||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214||||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214||||||||
|DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217|DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217|DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217|||||DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217|||DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217|||DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217|DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217|||DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217||||DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217||DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217|||DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217|||
|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223||P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223||P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223||P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223||P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223||P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223|
209
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Introduction**
## STAY CONNECTED WITH CORCOM PRODUCTS
TE Connectivity (TE) is a world leader in EMI-RFI filtering technology. Since 1955, TE has been providing EMI-RFI solutions to leading computer, industrial and telecommunications companies worldwide. Whether you are meeting FCC and international EMC standards on EMI-RFI emissions or developing a newly designed piece of equipment from being disturbed by EMI-RFI in the environment, a power line filter will help your equipment with compliance.
T This his s section ection h highlights ighlights T TE’s E’s p product roduct o offering ffering o of f D DC C r rated ated p products. roducts. Whether the issues involve filtering noise on the data lines or on the power lines, TE can provide the needed solutions for both susceptibility and to help achieve system emissions and immunity compliance.
> A As s n new ew t technologies echnologies i in n t the he T Telecom elecom ~~-~~ D Datacom atacom i indus ndus ~~-~~ t try ry a are re d developed eveloped a and nd i introduced ntroduced, TE continues to design and develop new products to address the EMI-RFI filtering issues. TE’s design engineers are very actively working with telecom and datacom system engineers to solve EMI-RFI issues.
I In n w working orking w with ith t two wo o of f t the he l leading eading N North orth A American merican c communications ommunications e equipment quipment c companies ompanies, TE engineers solved the EMI-RFI issues present by applying 48 VDC filters at the primary input of the DC power supply. One of the applications was on network routing equipment and required a two-stage 48VDC filter on the input to the DC power supply. TE applied highfrequency attenuating 48VDC filters on the load side of the DC power supplies to solve high-frequency EMI-RFI issues.
**==> picture [188 x 182] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cooling Module<br>Ports<br>Trunk Modules<br>Control Modules<br>Protection<br>Modules<br>Alarm Module<br>48VDC Line Filters —| |<br>jU | *<br>Typical Piece of Communications<br>Equipment Utilizing 48VDC Filters<br>**----- End of picture text -----**<br>
> T TE E h has as p provided rovided s solutions olutions i in n b both oth p power ower l line ine fi filtering ltering
> a and nd s signal ignal l line ine fi filtering ltering a applications pplications for many leading communications companies. As data transmission speeds increase and EMI-RFI issues multiply, TE has developed products to better solve the newer challenges communications companies encounter.
## Corcom DC power line and signal line filters have been included in:
- Network routing equipment
- Servers
- Modems
- Switching equipment
- Wireless cabinets
- Ethernet hubs
- Base stations
- Repeater stations
- Power supplies for all types of communications equipment
## TE has developed DC filter products specifically for the communications industry including:
- DC power line clean-up filters
- Medium and multiple-stage high-performance DC power line filters
- High frequency DC power line filters (up to 3GHz)
- High current DC power line filters (up to 60A)
- Data-transmission signal line filters
C Corcom orcom D DC C fi filters lters a are re a available vailable i in n v versions ersions t that hat c can an s solve olve a a w wide ide v variety ariety o of f E EMI MI ~~-~~ RFI RFI i issues. ssues. TE has solved basic EMI-RFI issues with simple cleanup DC filters and has solved more complex EMI-RFI issues with mid-range and multiple-stage high performing DC filters. TE has also solved high-frequency noise problems (up to 3GHz) encountered with high-speed data transmission and switching power supplies.
210
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**4**
## **Selector Chart**
**==> picture [239 x 183] intentionally omitted <==**
**----- Start of picture text -----**<br>
Compact<br>DC Inlet<br>Connector<br>Yes No<br>Fuse<br>Required<br>Yes No<br>Try The Try The Try The<br>P DA DC<br>DC Series Series Series<br>3-10A 3-20A 15-125A<br>Page 223 Page 212 Page 217<br>DB<br>Series<br>60A<br>Page 214<br>NEW<br>**----- End of picture text -----**<br>
|Series|Input|Output|Mounting|Options|Current<br>Rating|
|---|---|---|---|---|---|
|P|2-pin Inlet|1/4” Terminal|Snap In Panel<br>_or_<br>Flange Panel|Fuse<br>~~a~~|3, 6, 10A|
|D<br>A<br>/<br>D<br>A<br>S<br>SETAE|3-pin Inlet|1/4” Terminal<br>_or_<br>PC Board|Snap In Panel<br>_or_<br>Flange Panel|—|3, 6, 10,<br>15A|
|D<br>B<br>DB<br>|2-pin<br>High Current<br>Inlet<br> 7|Wire Leads|Flange Panel<br>and<br>Rear Mount|Compact,<br>Standard,<br>Feedthrough<br>& Hi-Performance<br>Filters<br>and<br>Unfiltered Inlet &<br>Plug available<br>Separately|60A|
|D<br>C<br>DC|Redundant Stud<br>Terminal Block<br>|Redundant Stud<br>_or_<br>Terminal Block|Bulkhead<br>_or_<br>Flange Chassis|Circuit Breaker<br>_and/or_<br>High Frequency<br>Performance|15, 30, 60,<br>100, 125A|
211
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Compact RFI Line Filter with DC Inlet Connection**
## DA Series
**==> picture [18 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
EN<br>60 950<br>**----- End of picture text -----**<br>
UL Recognized CSA Certified TUV Certified
**==> picture [174 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
DAFP DAF1 DAS1<br>**----- End of picture text -----**<br>
## D DA A S Series eries
- General purpose line filters for DC applications up to 125VDC.
- Compact with a 3-pin inlet connector
- Available in 3, 6, 10 and 15A versions
- Flange mount with 1/4” or PCB terminals
- Mates with a standard MOLEX* connector (HCS Series)
## O Ordering rdering I Information nformation
**==> picture [223 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 DA F 1<br>L O Output utput S Styles tyles<br>1 – .250 [6.3] spade terminals<br>P – PC board mount pins<br>C Case ase S Style tyle<br>F – Flange mount<br>S – Snap-in<br>D DA A Series Series<br>Current Rating<br>3, 6, 10 or 15A<br>Current Rating<br>**----- End of picture text -----**<br>
## S Specifications pecifications
Hipot rating (one minute): Line to Ground: 2250 VDC LIne to Line: 1450 VDC Rated Voltage (max): 125 VDC Rated Current: 3 to 15A
Operating Ambient Temperature Range (at rated current Ir): -10°C to +55°C In an ambient temperature (Ta) higher than +55°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
**==> picture [215 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
E Electrical lectrical Schematic Schematic<br>LINE LOAD<br>a l Co rir<br>A Accessories ccessories<br>Red<br>Green/Yellow<br>Black<br>=<br>**----- End of picture text -----**<br>
## A Available vai ; lable P Part art N Numbers umbers
|3DAF1<br>3DAS1<br>3DAFP<br>6DAF1<br>6DAS1<br>6DAFP|10DAF1<br>10DAS1<br>10DAFP<br>15DAF1<br>15DAS1<br>15DAFP|
|---|---|
G GA310 A310 – (shown above) Pre-assembled connector housing and terminals with three 36” long 18 gauge wires to mate with DA Series filters
MOLEX* connector part numbers:
03-12-1036 Connector housing for DA Series 18-12-1222 Female terminals (3 per connector)
212
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**4**
## **Compact RFI Line Filter with DC Inlet Connection** _(continued)_
## DA Series
## C Case ase S Styles tyles
## C Case ase D Dimensions imensions
|Part No.|A<br>|B<br>|C<br>|D<br><br>__|E<br>|
|---|---|---|---|---|---|
|DAF1<br>DAS1|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|
|DAFP|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
**==> picture [494 x 540] intentionally omitted <==**
**----- Start of picture text -----**<br>
DAF1 Part No. <br> <br> <br>C DAF1 <br>[_ E: ep<br> <br>D A B DAS1<br>iB E < 1 ] — = <br> <br><br>DAFP<br> <br> <br> <br><br>R Recommended ecommended P Panel anel C Cutouts utouts<br>DAS1<br>DAF<br>A<br>0.23 max.<br>.820 .900<br>_ ae y 4 20.8 4 22.9<br>D C<br>1.200 .140 3.56 Dia. (2) 1.200 .140 3.56 Dia. (2)<br>30.48 30.48<br>ioa E r + _ 1.575 40.01 _ 3.05 7 .12 R —_ TI 1.575 40.01 NK .234 5.94 _ R<br>Back Mount Front Mount<br>B<br>DAS<br>"A"<br>Rear View <br> 0.815 <br> 20.70<br> R 0.188 <br>4.78<br>(Gla b B (4x) Oo<br>DAFP<br>“| .551 Foy P Performance erformance D Data ata<br>Aid + .380 Max. lI<br>.537 Ref. = C Minimum Insertion Loss<br>=| Cp Measured in closed 50 Ohm system<br>D —_ A B Common Mode / Asymmetrical (Line to Ground)<br>E<br> <br> <br> <br><br> <br>P PC C B Board oard L Layout ayout <br>Ground <br>0.104 2.64 (3 holes) Differential Mode / Symmetrical (Line to Line)<br>0.520 <br>13.21 <br> <br>0.551<br>Center pin to panel .685±.015 13.99 <br>— 17.40.38 ++<br>**----- End of picture text -----**<br>
|****||||****|****|****|****|****||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|****<br><br><br>|****<br><br><br><br><br><br>||****<br><br><br>|****<br><br><br>|****<br><br><br>|****<br><br><br>|****<br><br><br>|****<br><br><br>|****<br><br><br><br><br><br><br><br><br>|||
|||||||||||||
213
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Compact RFI High Current DC Inlet Connection**
## DB Series
EN 60 950 WEG > UL Recognized CSA Certified TUV Certified
**==> picture [33 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
60DB8<br>60DBJ8<br>**----- End of picture text -----**<br>
## DB S Seriesriesiesess DB B S Seriesriesiesess Series eriesriesiesess
## DB S Seriesriesiesess
- Compact connector for high-current DC applications
- Reliable performance in a compact assembly
- Polarized mating scheme
- Easy customer termination of power source
- Plug and receptacle available pre-terminated in standard wire lengths
- Available filtered or unfiltered
## O Ordering rdering I Information nformation
## S Specifications pecifications
Hipot rating (one minute):
||Filtered Models|DBR & DBP|
|---|---|---|
|Line to Ground:|2121 VDC|n/a|
|LIne to Line:|1768 VDC|1600 VAC|
|Rated Voltage (max):|150VDC*|300 VDC|
Rated Current: 60A _(all versions)_
Operating Ambient Temperature Range (at rated current Ir): -10°C to +55°C In an ambient temperature (Ta) higher than +55°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/30
In an ambient temperature (Ta) higher than +55°C
60 DB F 8 LL Output Output Styles Styles Filtered Models 8 – 6” Wire leads Connector Only L1 – 1’ Cable pair L3 – 3’ Cable pair L9 – 9’ Cable pair Omit for none T Type ype R – Receptacle with clips P – Plug with clips J – Compact filter F – Feedthrough capacitors X – High performance Blank – Standard filter D DB B S Series eries Current Rating 60A ——
## A Available vailable P Part art N Numbers umbers
|Filtered Models|
|---|
|60DB8<br>60DBJ8|
|60DBF8<br>60DBX8|
|Connectors Only|
|60DBR<br>60DBP|
|60DBRL1<br>60DBPL1|
|60DBRL3<br>60DBPL3|
|60DBPL9|
|**WARNING**<br>This is not approved for hot swap or current<br>interruption in DC applications. Doing so will<br>result in irreparable damage to contacts.<br>SO|
214
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Compact RFI High Current DC Inlet Filter** _(continued)_
## DB Series
## Electrical Schematics
## DB8 & DBJ8
**==> picture [202 x 50] intentionally omitted <==**
**----- Start of picture text -----**<br>
-VDC<br> (Black)<br>RTN<br> (Red)<br>Line Load<br>**----- End of picture text -----**<br>
**==> picture [242 x 403] intentionally omitted <==**
**----- Start of picture text -----**<br>
DBF8<br>-VDC<br> (Black)<br>RTN<br>SFE (Red)<br>DBX8<br>-VDC<br> (Black)<br>re C ora RTN<br> (Red)<br>ee 60DBPL 60DBRL<br>Available as connector only (shown)<br>or with pre-installed 6AWG 300V Extra Flexible wire<br>Line Load<br>Line Load<br>**----- End of picture text -----**<br>
## Case Styles
## DBJ8
**==> picture [229 x 79] intentionally omitted <==**
**----- Start of picture text -----**<br>
E<br>D A 6.0 Min. 2.087<br>F 0.375<br>0.591 (ref)<br>C 0.965 1.04 Max.<br>Wire #6 AWG, 300V<br>Extra Flexible<br>0.150 Connector Dia. IAW UL10198 B<br>0.140 Can Dia. (2 x)<br>| )<br>Red (RTN)<br>Label<br>Black (-VDC)<br>**----- End of picture text -----**<br>
**==> picture [241 x 346] intentionally omitted <==**
**----- Start of picture text -----**<br>
DB8 & DBF8<br>C A 6.0 Min.<br>E<br>0.277 0.375(ref)<br>0.297<br>ay a<br>0.423 Red (RTN)<br>B D F Label Black (-VDC)<br>fh oe Wire #6 AWG, 300V<br>Extra Flexible<br>#6-32 Thread #4-40 Thread IAW UL10198<br>(4x) (2x) | (2 x)<br>DBX8<br>C A 6.0 Min.<br>E<br>0.277 0.375(ref)<br>0.297 fl Ly Red (RTN) op<br>0.423<br>B D F Label<br>Black (-VDC)<br>Wire #6 AWG, 300V<br>Extra Flexible<br>#6-32 Thread #4-40 Thread IAW UL10198<br>(4x) (2x) (2 x)<br>ee<br>**----- End of picture text -----**<br>
**4**
215
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**Compact RFI High Current DC Inlet Filter** _(continued)_
## DB Series
## C Case ase S Styles tyles _(continued)_ DBPL
**==> picture [241 x 94] intentionally omitted <==**
**----- Start of picture text -----**<br>
C A<br>D E<br>B<br>F<br>Black (-VDC) Wire #6 AWG, 300V<br>Extra Flexible<br>IAW UL10198<br>(2 x)<br>Red (RTN)<br>**----- End of picture text -----**<br>
## DBRL
**==> picture [242 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
C A<br>D E<br>B<br>F<br>a —<br>"(ClO CO<br>0.150 Dia. a<br>2x Black (-VDC) Wire #6 AWG, 300V<br>Extra Flexible<br>IAW UL10198<br>(2 x)<br>Red (RTN)<br>|<br>**----- End of picture text -----**<br>
## C Case ase D Dimensions imensions
|||A|B|C|D|E|F|
|---|---|---|---|---|---|---|---|
|PartNo.||||<br>__|<br>__|<br>__|<br>__|
|60DBJ8||****<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>__||||||
|60DB8||****|****|****|****|****<br>****||
|60DBF8||__<br>__<br>__<br>__<br>__<br>__||||||
|60DBX||****<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>__||||||
|60DBRL||****<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>__||||||
|60DBPL||****<br>****<br>****<br>****<br>****<br>****<br>__<br>__<br>__<br>__<br>__<br>__||||||
|||||||__||
## P Performance erformance D Data ata
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
## Recommended Panel Cutout
**==> picture [241 x 128] intentionally omitted <==**
**----- Start of picture text -----**<br>
a 1.654 0.138 Dia. (2x) 3.50 1.654 0.138 Dia. (2x)<br>42.01 42.01 3.50<br>R 0.062 1.370 / OO R 0.125 a 1.3 / _<br>(4x) 1.57 34.79 (4x) 3.175 33.02<br>tf 1.055 — 0.985<br>26.79 0.528 ' 25.01 0.493<br>13.41 12.52<br>Front Mount Panel Cutout Rear Mount Panel Cutout<br>Tolerance ± .005 Tolerance ± .005<br><br> <br> <br> <br>**----- End of picture text -----**<br>
## A Accessories ccessories / / T Tooling ooling
|Insertion/Extraction Tool:|1643922-1*|
|---|---|
|Crimp per TE spec:|114-13206|
|Crimp tool:|M22520/23-01|
|Indenter head:|M22520/23-04|
|Locator:<br>Connector system locking kit¹:|M22520/23-11<br>ContactTE|
## ****
||****|
|---|---|
|****|****<br>****<br>****<br>****<br>****<br>****<br>****<br>****<br>****<br>****|
|<br><br><br><br><br><br><br><br><br><br><br>****<br>—————————_——_<br>0.00000 n—nwX—X—m—X=X=—ss.l_<a||
|****<br>****<br>****<br>****<br>****<br>****<br>****<br>****<br>****<br>****<br>****||
|<br>|<br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br>|
||<br><br><br><br><br><br><br><br><br>|
Differential Mode / Symmetrical (Line to Line)
|||||****||||
|---|---|---|---|---|---|---|---|
|****<br>****<br>****<br>****<br>****<br>****<br>****<br>****<br>****<br>****<br>****<br><br><br><br><br><br><br><br><br><br><br><br>~~a~~||||||||
|||||****||||
|****<br>****<br>****<br>****<br>****<br>****<br>****<br>****|||||****|****|****|
|||||<br><br><br>||||
|||||<br><br><br>||||
|||||<br><br><br>||||
216
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**4**
## **RFI Power Line Filters for DC Applications**
## DC Series
**==> picture [93 x 20] intentionally omitted <==**
**----- Start of picture text -----**<br>
EN<br>60 950<br>WG a)<br>**----- End of picture text -----**<br>
UL Recognized CSA Certified TUV Certified
**==> picture [137 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
60DCF6B 15DCF10<br>**----- End of picture text -----**<br>
## D DC C S Series eries
- General purpose line filters for DC applications up to 125VDC
- Available with or without a circuit breaker
- Available with feedthrough capacitors for added high frequency performance
- Available in both flange mound (DCF) and bulkhead mount (DCB) configuration
## S Specifications pecifications
Hipot rating (one minute): Line to Ground: 2250 VDC LIne to Line: 1450 VDC Rated Voltage (max): 80 VDC Rated Current: 15 to 125A Operating Ambient Temperature Range (at rated current Ir): -10°C to +55°C In an ambient temperature (Ta) higher than +55°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/30
## O Ordering rdering I Information nformation
## 60 DC B 6 B
O Options ptions B – Circuit breaker F – Feedthrough capacitors BF – Circuit breaker and feedthrough _F and BF available only in bulkhead (B) mounting style_ Omit for none I Input nput / / O Output utput S Styles tyles 6 – Redundant stud 10 – Phoenix terminal Mounting Style F = Flange B = Bulkhead and rack —— _Required for F or BF options_ D DC C S Series eries C Current urrent R Rating ating 15, 30, 60, 100 or 125A
## Electrical Schematics Electrical Schematics
## Standard Performance
**==> picture [241 x 211] intentionally omitted <==**
**----- Start of picture text -----**<br>
Note 2<br>Note 3<br>LINE LOAD<br>Note 1 Note 1<br>Note 4<br>High Frequency Performance (F & BF Styles)<br>Note 2<br>LINE LOAD<br>Note 3 Note 1<br>““HYE EB =<br>Note 4 ~<br> <br> <br> <br> <br>**----- End of picture text -----**<br>
## High Frequency Performance _(F & BF Styles)_
217
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **RFI Power Line Filters for DC Applications** _(continued)_
## DC Series
## A Available vailable P Part art N Numbers umbers
|Standard Performance|Standard Performance|High Performance|High Performance|
|---|---|---|---|
|15DCF6<br>30DCF6<br>60DCF6<br>100DCF6<br>125DCF6<br>15DCF6B<br>30DCF6B<br>60DCF6B<br>100DCF6B<br>125DCF6B<br>15DCB6<br>30DCB6<br>60DCB6<br>100DCB6<br>125DCB6<br>15DCB6B<br>30DCB6B<br>60DCB6B<br>100DCB6B<br>125DCB6B|15DCF10<br>30DCF10<br>60DCF10<br>100DCF10<br>125DCF10<br>15DCF10B<br>30DCF10B<br>60DCF10B<br>100DCF10B<br>125DCF10B<br>15DCB10<br>30DCB10<br>60DCB10<br>100DCB10<br>125DCB10<br>15DCB10B<br>30DCB10B<br>60DCB10B<br>100DCB10B<br>125DCB10B|15DCB10F<br>30DCB10F<br>60DCB10F<br>100DCB10F<br>125DCB10F<br>15DCB6BF<br>30DCB6BF<br>60DCB6BF<br>100DCB6BF<br>125DCB6BF<br>15DCB10BF<br>30DCB10BF<br>60DCB10BF<br>100DCB10BF<br>125DCB10BF|15DCB6F<br>30DCB6F<br>60DCB6F<br>100DCB6F<br>125DCB6F|
## T Termination ermination O Options ptions
## Style 6 (15, 30 & 60A)
- Supplied with #10-32 redundant studs
- 0.625 [ _15.88_ ] spacing like polarity
- 0.750 [ _19.05_ ] spacing opposing polarity
- Torque specification: 27 ±3 in-lb.
## Style 10 (15 & 30A)
- PHOENIX CONTACT* part number: VDFK4
- Accepts 12 AWG stranded wire
- Wire strip length: 0.315 [ _8.0_ ]
- Torque specification: 5.5 – 7.0 in-lb.
- Ground stud: 8-32
## Style 10 (100A)
- PHOENIX CONTACT* part number: HDFK 25-VP
- Accepts 4 AWG stranded wire
- Wire strip length: 0.748 [ _19.0_ ]
- Torque specification: 35.4 – 39.9 in-lb.
- Ground stud: 1/4-20
## Style 6 (100 & 125A)
- Supplied with 1/4-20 redundant studs
- 0.750 [ _19.05_ ] spacing like polarity
- 1.00 [ _25.4_ ] spacing opposing polarity
- Torque specification: 45 ±2 in-lb
## Style 10 (60A)
- PHOENIX CONTACT* part number: HDFK 16-VP
- Accepts 6 AWG stranded wire
- Wire strip length: 0.630 [ _16.0_ ]
- Torque specification: 17.7 – 21.2 in-lb.
- Ground stud: 10-32
## Style 10 (125A)
- PHOENIX CONTACT* part number: HDFK 50-VP
- Accepts 1 AWG stranded wire
- Wire strip length: 0.945 [ _24.0_ ]
- Torque specification: 35.4 – 39.9 in-lb.
- Ground stud: 1/4-20
218
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**4**
## **RFI Power Line Filters for DC Applications** _(continued)_
## DC Series
## R Recommended ecommended P Panel anel C Cutouts utouts
## C Cutout utout D Dimensions imensions
## DCB6(F) & DCB10(F)
**==> picture [241 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
Holes: .157 [ 3.99 ] Dia. (4)<br>C<br>See case dimensions for spacing<br>B<br>ani<br>Tolerance: ±.005 [ .13 ]<br>pm A<br>**----- End of picture text -----**<br>
## DCB6(F) & DCB10(F)
||P<br>a<br>r<br>t<br>N<br>o<br>.<br>Part No.|A<br>A|B|C<br>Cc|
|---|---|---|---|---|
||15DCB6(F)|****|****|****|
||30DCB6(F)|__|__|__|
|15DCB10(F)<br>30DCB10(F)<br>****<br>__<br>60DCB6(F)<br>****<br>__<br>60DCB10(F)<br>****<br>__<br>100DCB6(F)<br>125DCB6(F)<br>****<br>__<br>100DCB10(F)<br>****<br>__<br>~~OO~~|||****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__|****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__|
||125DCB10(F)|****<br>__|****<br>__|****<br>__|
## DCB6B(F) & DCB10B(F) 15 to 60A
**==> picture [241 x 93] intentionally omitted <==**
**----- Start of picture text -----**<br>
D<br>C Holes: .157 [ 3.99 ] Dia. (4)<br>See case dimensions for<br>i ss ee spacing.<br>B F<br>Tolerance: ±.005/ .13<br>A E<br>**----- End of picture text -----**<br>
## DCB6B(F) & DCB10B(F) 15 to 60A
||P<br>a<br>r<br>t<br>N<br>o<br>.<br>Part No.|A<br>A|B|C<br>(os|D<br>D|E<br>E|F<br>F|
|---|---|---|---|---|---|---|---|
||15DCB6B(F)|****|****|****|****|****|****|
||15DCF6B|__|__|__|__|__|__|
|15DCB10B(F)<br>15DCF10B<br>30DCB6B(F)<br>~~Ol~~||****<br>__<br>****|****<br>__<br>****|****<br>__<br>****|****<br>__<br>****|****<br>__<br>****|****<br>__<br>****|
||30DCF6B|__|__|__|__|__|__|
||30DCB10B(F)|****|****|****|****|****|****|
||30DCF10B<br>60DCB10B(F)|__<br>****|__<br>****|__<br>****|__<br>****|__<br>****|__<br>****|
||60DCF10B|__|__|__|__|__|__|
||60DCF6B(F)|****|****|****|****|****|****|
||60DCF6B|__|__|__|__|__|__|
## DCB6B(F) & DCB10B(F) 100 to 125A
**==> picture [241 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
Holes: .157 [ 3.99 ] Dia. (4)<br>C See case dimensions for<br>spacing.<br>1.250 B<br>31.75 .625<br>ae 15.88<br>Tolerance: ±.005/ .13<br>PEP .262 6.65 1.557 39.55 Vi A a<br>1.500 x 0.781<br>38.10 x 19.84<br>**----- End of picture text -----**<br>
## DCB6B(F) & DCB10B(F) 100 to 125A
|P<br>a<br>r<br>t<br>N<br>o<br>.<br>Part No.|P<br>a<br>r<br>t<br>N<br>o<br>.<br>Part No.|A<br>A|B|C<br>(oe|
|---|---|---|---|---|
|100DCB6B(F)||****|****|****|
|100DCF6B<br>125DCB6B(F)<br>125DCF6B<br>100DCB10B(F)<br>100DCF10B<br>125DCB10B(F)<br>125DCF10B||__<br>****<br>__<br>****<br>__<br>****<br>__|__<br>****<br>__<br>****<br>__<br>****<br>__|__<br>****<br>__<br>****<br>__<br>****<br>__|
219
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **RFI Power Line Filters for DC Applications** _(continued)_
## DC Series
## Case Styles
## DCB6 & DCB6B
## DCB10 & DCB10B (60 to 125A)
**==> picture [480 x 566] intentionally omitted <==**
**----- Start of picture text -----**<br>
C A C A<br>F E E<br>RTN<br>-VDC L L L L<br>B D NI OA D B NI OA<br>E D RTNVDC E D<br>-VDCRTN<br>\<br>Tapped insert: 6-32 (4) F Tapped insert: 6-32 (4)<br> <br>DCF6 DCF10 (15 & 30A)<br>C A C A<br>E E<br>RTN RTN<br>re L L L L<br>B D NI OA B D NI OA<br>E D E D<br>-VDC -VDC<br>F F<br> <br> <br> <br>DCF6B DCF10 (60 to 125A)<br>C A C A<br>E E<br>RTN<br>B D -VDC NELI ODAL RTN B D -VDCRTN NELI ODAL -VDCRTN<br>-VDC<br>Tapped insert: 6-32 (4) F F<br> <br> <br>DCB10 & DCB10B (15 to 30A) DCF10B (15 & 30A)<br>C A C A<br>E E<br>RTN RTN<br>_ aa -VDC L — L = -VDC L L<br>D B NI OA B D NI OA<br>E D RTN E D RTN<br>-VDC -VDC<br>= = | _ i | | P o d<br>Tapped insert: 6-32 (4)<br>F Tapped insert: 6-32 (4) F<br> <br> <br>VDC RTN<br>OFF OFF<br>ON ON RTN VDC<br>-VDC RTN RTN -VDC<br>OFF<br>ON<br>OFF OFF<br>ON ON<br>**----- End of picture text -----**<br>
220
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**4**
## **RFI Power Line Filters for DC Applications** _(continued)_
## DC Series
## C Case ase S Styles tyles _(continued)_
## C Case ase D Dimensions imensions _(continued)_
## DCF10B (60 TO 125A)
**==> picture [493 x 556] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|C|A|A|B|C|D|E|F|
|E|
|||
|Part No.|||||||
|©,|—|
|||||||
|B|r|k|i|D|a|NLILII|OALAL|©|60DCB6(F)||||oS||||
|E|D|||||||
|60DCB6B(F)|
|||||||
|eo|>|||||||
|||\|Tapped insert: 6-32 (4)|||F|B|60DCF6|——|||||||
||||||||
|||||60DCF6B|||||||
|C|Case|ase D|Dimensions|imensions|a|||||||
|60DCF10|
|||||||
|A|B|C|D|E|F|
|||||||
|Part No.|||||||||60DCF10B|||||||
|||||||||||||
|15DCB6(F)|100DCB6(F)|
|||||||||||||
|||||||||||||
|15DCB6B(F)|100DCB6B(F)|
|||||||||||||
|||||||||||||
|15DCB10(F)|100DCB10(F)|
|||||||||||||
|||||||||||||
|15DCB10B(F)|100DCB10B(F)|
|||||||||||||
|||||||||||||
|15DCF6|100DCF6|
|||||||||||||
|||||||||||||
|15DCF6B(F)|100DCF6B|
|||||||||||||
|||||||||||||
|15DCF10|100DCF10|
|||||||||||||
|||||||||||||
|15DCF10B(F)|100DCF10B|
|||||||||||||
|||||||||||||
|30DCB6(F)|125DCB6(F)|
|||||||||||||
|||||||||||||
|30DCB6B(F)|125DCB6B(F)|
|||||||||||||
|||||||||||||
|30DCB10(F)|125DCB10(F)|
|||||||||||||
|||||||||||||
|30DCB10B(F)|125DCB10B(F)|
|||||||||||||
|||||||||||||
|30DCF6|125DCF6|
|||||||||||||
|||||||||||||
|30DCF6B|125DCF6B|
|||||||||||||
|||||||||||||
|30DCF10|125DCF10|
|||||||||||||
|||||||||||||
|30DCF10B|125DCF10B|
|||||||||||||
**----- End of picture text -----**<br>
**==> picture [223 x 123] intentionally omitted <==**
**----- Start of picture text -----**<br>
C A<br>E<br>©,<br>r k i L<br>B D a NLILII OALAL ©<br>E D<br>eo ><br>| | B<br>\<br>Tapped insert: 6-32 (4) F<br><br> <br>VDC RTN<br>OFF<br>ON RTN VDC<br>**----- End of picture text -----**<br>
221
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **RFI Power Line Filters for DC Applications** _(continued)_
## DC Series
## P Performance erformance D Data ata _(continued)_
## Minimum Insertion Loss
Measured in closed 50 Ohm system
## Standard Performance
Common Mode / Asymmetrical (Line to Ground)
|****||||****|****|****|****||||
|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****|****|****|
||||||||||||
||||||||||||
||||||||||||
||||||||||||
||||||||||||
|Differential Mode / Symmetrical (Line to Line)|Differential Mode / Symmetrical (Line to Line)||||||Differential Mode / Symmetrical (Line to Line)||||
|****||||****|||||||
|****|****|****|****|****|****|****|****|****|****|****|
||||||||||||
||||||||||||
||||||||||||
||||||||||||
||||||||||||
## High Frequency Performance (F & BF Styles)
Common Mode / Asymmetrical (Line to Ground)
|****||||****|****|****|****||||****<br>****|****<br>****|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****|****|****|****|****|
||||||||||||||
||||||||||||||
||||||||||||||
||||||||||||||
||||||||||||||
## Differential Mode / Symmetrical (Line to Line)
|****||||****|****|****|****||||
|---|---|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****|****|****|
||||||||||||
||||||||||||
||||||||||||
||||||||||||
||||||||||||
222
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**4**
## **The CHAMELEON Adaptable Module for DC Applications**
## P Series
EN 60 950
UL Recognized CSA Certified TUV Certified
## P Seriesriesiesess P Seriesriesiesess Series eriesriesiesess
## P Seriesriesiesess
- Full flexibility of design in the most compact package
- General purpose designed for DC applications
- Mates with a standard MOLEX* connector (HCS Series) which prevents accidental connection to AC Power
## O Ordering rdering I Information nformation PS000DD3D
Shield Options D = Complete Shield _(DC Version)_ \ C Current urren Options t R Rating ating 3 = 3A 6 = 6A X = 10A Filter Type D = DC version Filter Type Fuse Options Fuse Options D = Dual fuse S = Single fuse
I Input nput V Voltage oltage S Select elect 0 = Single voltage S Switch witch O Options ptions 0 = No switch E Extender xtender O Options ptions 0 = None M Mounting ounting S Style tyle E = Mounting ears S = Snap-in
## S Specifications pecifications
Hipot rating (one minute): Line to Ground: 2250 VDC LIne to Line: 1450 VDC Rated Voltage (max): 80 VDC Rated Current: 3 to 10A Fuseholder*: .25 x 1.25” or 5 x 20 mm
Terminals: .187 x .032 [ _4.8 x .81_ ] terminal tabs Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 —___— E Electrical lectrical S Schematic chematic LINE Se ~~i=~~ LOAD
## A Available vailable P Part art N Numbers umbers
|PE000DD3D<br>PE000DD6D<br>PE000DDXD<br>PE000SD3D<br>PE000SD6D<br>PE000SDXD|PS000DD3D<br>PS000DD6D<br>PS000DDXD<br>PS000SD3D<br>PS000SD6D<br>PS000SDXD|
|---|---|
223
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **The CHAMELEON Adaptable Module for DC Applications** _(continued)_
## P Series
## C Case ase S Styles tyles
## C Case ase D Dimensions imensions
## PE
**==> picture [383 x 286] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|A|B|C|D|E|F|
|Part No.|
|—|||||||
|||||||
|PE|
|||||||
|y|[—|EEa|
||||||
|C|PS||
||||||
||||||
|Recommended Panel Cutouts|
|[||k|s|Recommended|Panel|Cutouts|
|B|1.52|.06|R Max.|
|_——|.07|_|
|1.78|min. Radius|
|Ground connection|
|E|
|——|
|External Edge|
|(1)|.020|R Min.|
|.508|
|C|L|_|
|D|
|Note: The external edges (installation side) on the "D" sides of the|
|iff|cutout should have a minimum .020" radius. For optimal retention|—|
**----- End of picture text -----**<br>
**==> picture [195 x 262] intentionally omitted <==**
**----- Start of picture text -----**<br>
C<br>[| k s<br>F B<br>A _—— .07<br>1.78 min. Radius<br>Ground connection<br>——<br>C L<br>iff<br>B<br>A J || bh= le—<br>**----- End of picture text -----**<br>
## PS
Note: The external edges (installation side) on the "D" sides of the cutout should have a minimum .020" radius. For optimal retention against extraction, the corresponding inner edge should be sharp, without paint or coatings. Edge coatings, including anodization are also discouraged for good shield contact.
## P Performance erformance D Data ata
## A Accessories ccessories
**==> picture [28 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
Red<br>Black<br>**----- End of picture text -----**<br>
G GA210 A210 – (shown above) Pre-assembled connector housing with two 36” long 18 gauge wires to mate with P Series DC filters
## Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
**==> picture [222 x 65] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|||
|||||||||||
|||||||||||
|||||||||||
|||||||||||
**----- End of picture text -----**<br>
Differential Mode / Symmetrical (Line to Line)
## MOLEX Part Numbers:
03-12-1026 DC Connector housing for P Series 18-12-1222 Female terminals (2 per connector)
**==> picture [222 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|||
||||||||||
||||||||||
||||||||||
||||||||||
**----- End of picture text -----**<br>
224
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **5. Feedthrough Filters and Capacitors — Table of Contents**
|F<br>e<br>e<br>d<br>t<br>h<br>r<br>o<br>u<br>g<br>h<br>A<br>Feedthrough|A<br>p<br>p<br>l<br>i<br>c<br>a<br>t<br>i<br>o<br>n<br>S<br>e<br>l<br>e<br>c<br>t<br>o<br>r<br>C<br> Application Selector|A<br>p<br>p<br>l<br>i<br>c<br>a<br>t<br>i<br>o<br>n<br>S<br>e<br>l<br>e<br>c<br>t<br>o<br>r<br>C<br> Application Selector|A<br>p<br>p<br>l<br>i<br>c<br>a<br>t<br>i<br>o<br>n<br>S<br>e<br>l<br>e<br>c<br>t<br>o<br>r<br>C<br> Application Selector|A<br>p<br>p<br>l<br>i<br>c<br>a<br>t<br>i<br>o<br>n<br>S<br>e<br>l<br>e<br>c<br>t<br>o<br>r<br>C<br> Application Selector|C<br>h<br>a<br>r<br>t<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>2<br>5<br> Chart .........cccecccccccevces<br>2 225|
|---|---|---|---|---|---|
|I<br>n<br>t<br>r<br>o<br>d<br>u<br>c<br>t<br>i<br>o<br>n<br>.<br>INCFOGMUCTION|.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2... cc ccc cece ccc||.<br>.<br>.<br>.<br> ccc||.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>2<br>6<br>c cas cccsssccasevcssevessecessess<br>DLO|
|FFA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228||. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228|
|FFD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231||||FFD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231||
|AFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234|AFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234|AFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234|AFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234||AFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234|
|DFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .237|DFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .237|DFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .237|DFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .237||DFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .237|
## **Feedthrough Application Selector Chart**
**==> picture [354 x 206] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type of<br>Filter Capacitor<br>Feedthrough<br>Application Application<br>AC DC AC DC<br>Try The Try The Try The Try The<br>FFA FFD AFC DFC<br>Series Series Series Series<br>Feedthrough Feedthrough Feedthrough Feedthrough<br>AC Filters DC Filters AC Capacitors DC Capacitors<br>Page 228 Page 231 Page 234 Page 237<br>**----- End of picture text -----**<br>
**5**
225
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Introduction – Corcom Feedthrough Filters and Capacitors**
## Installation, Background and Safety
Feedthrough capacitors and filters are designed for through-bulkhead mounting for offering high frequency filtering in line-to-ground applications. They should be mounted through a metal bulkhead or chassis. The bulkhead mounting surface should be clean and unpainted to offer a low impedance path from the capacitor or filter to the equipment chassis. Poor earth bonding will limit the available performance of the product and could compromise safety.
Conductive paint finishes should be avoided as they do not usually provide adequate conductivity. Two wrenches (or spanners) should be used when making electrical connections to the terminals and maximum tightening torque figures quoted should be observed.
Relevant safety standards have been adhered to in the design and manufacture of these products. However, all capacitors will store charge after power has been removed and must be treated with respect as this can be lethal when the voltage and charge are high enough. The filters and capacitors contained within this catalog do not contain internal discharge resistors. It is therefore recommended that they are fitted with external discharge resistors to discharge the capacitors after the power has been removed. Where necessary, terminals should be enclosed by the user to prevent any danger of electric shock or accidental shorting. In all cases, capacitors and filters should always be shorted to earth prior to touching to ensure they are fully discharged.
## Applications
Offers reliability and performance in high frequency applications such as:
- Servers
- Base stations
- Routers
- Main power supplies
- Telecom systems / racks
- MRI rooms
- High power microwave lines
- Military vehicles and equipment
- High current switch mode power supplies
- Power amplifier and generators
- Industrial controls
- Screened rooms
- High frequency welding equipment
- Secure communications
- Computer facilities
## Key Features
- Designed to meet EN133200 and EN132400 safety requirements
- Custom designs available where special packaging, mounting, terminations, or multiple lines are required.
- RoHS compliant
The user should ensure he/she is familiar with restrictions on capacitance value, earth leakage current, test voltage, and safety labeling requirements, which may be applicable to his/her particular installation. In particular, safety standards IEC950 and EN60950, which most electrical equipment needs to comply with, contain a number of specific requirements for capacitors, which may be applicable.
226
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**5**
## **Introduction – Corcom Feedthrough Filters and Capacitors**
## Feedthrough Capacitor Performance
- Normal two-terminal capacitors resonate with their lead inductance in the region of 1 to 10MHz
- This limits their use as suppression components above a few MHz
- Feedthrough capacitors have no major resonance as they have no lead inductance
- Performance continues to increase with frequency
- Feedthrough capacitors are essential for good high frequency performance
- Feedthrough filters incorporate feedthrough capacitors for the same benefits
Figure 1: Feedthrough Filters Performance
**==> picture [219 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
0<br>10 10<br>ROLL<br>PNT Two-Terminal 20<br>1 SO Capacitor 30<br>OTP ET 40<br>0.1 50<br>CONE Feedthrough<br>CSS ac Actual 60<br>0.01 FCoE Theoretical Gil 70<br>80<br>COE TI<br>0.001 1 90<br>100<br>10K FCA 100K eo 1M 10M Fri 100M<br>Frequency (Hz)<br>Ω)<br>IMPEDANCE (<br>INSERTION LOSS IN 50 OHM SYSTEM (dB)<br>**----- End of picture text -----**<br>
- As an example, the graph in Figure 1 compares the performance of a 1F feedthrough capacitor with a 1F two-terminal capacitor
227
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **AC Feedthrough Filters – Class Y2**
## FFA Series
Component Recognized by UL to US and Canadian Requirements
## F FFA FA S Series eries
- AC feedthrough filters
- Current Ratings from 10 to 300A
- Designed to meet the very stringent safety requirements of EN133200 class Y2 including the 5000V pulse test
- Custom versions available
## O Ordering rdering I Information nformation
## 10 FFA6 – BA
- ~~L~~ F Filter ilter I ID D See Table
F FFA FA S Series eries S Screw crew T Terminals erminals
C Current urrent R Rating ating _(in A)_
## F Filter ilter O Options ptions / / S Specifications pecifications
||||Max.<br>Leakage|DC|
|---|---|---|---|---|
|Filter||Inductance|Current|Resistance|
|ID<br>BA|Value (nF)<br>2 x 4.7|(nH)<br>70|(mA)*<br>0.9|(m)Max.<br>6|
|CA|2 x 10|70|1.9|4|
|CE|2 x 10|140|1.9|7|
|DG|2 x 22|170|4.2|4|
|DH|2 x 22|180|4.2|4|
|GB|2 x 47|80|8.9|3|
|GJ|2 x 47|210|8.9|9|
|HC|2 x 100|90|19|2|
|HD<br>HF<br>HN<br>JK|2 x 100<br>2 x 100<br>2 x 100<br>2 x 150|120<br>160<br>250<br>240|19<br>19<br>19<br>29|1<br>< 1<br>6<br>3|
|NP|2 x 470|330**|89|< 2|
|PP|2 x 1000|330|188|< 2|
|||| ||
|||| ||
## S Specifications pecifications
Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 10 to 300A Test Voltage (two seconds): 5000 VDC Capacitor Class (EN133200): Designed to meet Y2 Pulse Test (EN133200): 5000V Peak Insulation Resistance (within 1 minute):
For C < 0.33F, R> 15000M For C > 0.33F, RC(M*F)>5000s
Operating Ambient Temperature Range (at rated current Ir):
10 to 100A: -40°C to +60°C 200A: -40°C to +50°C 250 & 300A: -40°C to +40°C
Category Temperature Range: -40°C to +85°C Current Derating Above Ambient:
10-100A: For temperature, = R ~~a~~ (85-)/25 200A: For temperature, = R (85-)/35 250 & 300A: For temp., = R (85-)/45 Climatic Category: 40/85/21 MTBF: > 5 million hours typical Insulating Materials Flammability Rating: UL94V-0 Case & Terminal Material: Nickel Plated Brass
## E Electrical lectrical S Schematic chematic
228
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**5**
## **AC Feedthrough Filters – Class Y2** _(continued)_
## FFA Series
## C Case ase S Style tyle
## C Case ase D Dimensions imensions
**==> picture [232 x 92] intentionally omitted <==**
**----- Start of picture text -----**<br>
Resin Fill T2 (Mounting thread)<br>T1 (Terminal thread)<br>a | [<br>B C D E F<br>|) A | | i<br>**----- End of picture text -----**<br>
## T1 – Terminal Thread
|Part No.<br>10FFA6-BA/CE/CJ|Thread<br>M3|Torque<br>max. in.lb.<br>4|
|---|---|---|
|16FFA6-CA/DG/HN<br>32FFA6-CA/DH/HN|M4|11|
|63FFA6-GB/JK/NP<br>100FFA6-HC/NP/PP|M6<br>M8|22<br>44|
|200FFA6-HD/NP/PP|M10|70|
|250FFA6-HF/NP/PP|M12|97|
|300FFA6-HF/NP/PP|M16|177|
## T2 – Mounting Thread
|Part No.<br>10FFA6-BA/CE/CJ|Thread|Torque<br>max. in.lb.|
|---|---|---|
|16FFA6-CA|M12 x 1|35|
|32FFA6-CA<br>16FFA6-DG/HN<br>32FFA6-DH/HN<br>63FFA6-GB<br>63FFA6-JK<br>100FFA6-HC<br>100FFA6-NP<br>200FFA6-HD<br>63FFA6-NP<br>100FFA6-PP<br>200FFA6-NP/PP<br>250FFA6-HF/NP/PP<br>300FFA6-HF/NP/PP|M16 x 1<br>M20 x 1<br>M24 x 1<br>M27 x 1.5<br>M32 x 1.5|62<br>89<br>124<br>142<br>212|
|Part No.|A<br>B<br>C<br>D<br>E<br><br>__<br><br>__<br><br>__<br><br>__<br><br>__<br>~~oo~~|A<br>B<br>C<br>D<br>E<br><br>__<br><br>__<br><br>__<br><br>__<br><br>__<br>~~oo~~|A<br>B<br>C<br>D<br>E<br><br>__<br><br>__<br><br>__<br><br>__<br><br>__<br>~~oo~~|A<br>B<br>C<br>D<br>E<br><br>__<br><br>__<br><br>__<br><br>__<br><br>__<br>~~oo~~|A<br>B<br>C<br>D<br>E<br><br>__<br><br>__<br><br>__<br><br>__<br><br>__<br>~~oo~~|F<br>|
|---|---|---|---|---|---|---|
|10FFA6-BA<br>16FFA6-CA<br>32FFA6-CA|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|
|63FFA6-GB<br>100FFA6-HC|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|
|200FFA6-HD|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|300FFA6-HF|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|10FFA6-CE|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|16FFA6-DG|****|****|****|****|****|****|
|32FFA6-DH|__|__|__|__|__|__|
|63FFA6-JK|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|100FFA6-NP<br>200FFA6-NP|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|
|250FFA6-NP|****<br>****||****|****|****|****|
|300FFA6-HN<br>10FFA6-GJ<br>16FFA6-HN<br>32FFA6-HN<br>63FFA6-NP<br>100FFA6-PP<br>200FFA6-PP<br>250FFA6-PP<br>300FFA6-PP|__<br>__<br>****<br>****<br>__<br>__<br>****<br>****<br>__<br>__<br>****<br>****<br>__<br>__<br>****<br>****<br>__<br>__<br>****<br>****<br>__<br>__<br>****<br>****<br>__<br>__||__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__|__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__|__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__|__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__|
229
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **AC Feedthrough Filters – Class Y2** _(continued)_
## FFA Series
## A Available vailable P Part art N Numbers umbers
|Standard Performance|High Performance|Extended Performance|
|---|---|---|
|10FFA6-BA<br>16FFA6-CA<br>32FFA6-CA<br>63FFA6-GB<br>100FFA6-HC<br>200FFA6-HD<br>250FFA6-HF<br>300FFA6-HF|10FFA6-CE<br>16FFA6-DG<br>32FFA6-DH<br>63FFA6-JK<br>100FFA6-NP<br>200FFA6-NP<br>250FFA6-NP<br>300FFA6-NP|10FFA6-GJ<br>16FFA6-HN<br>32FFA6-HN<br>63FFA6-NP<br>100FFA6-PP<br>200FFA6-PP<br>250FFA6-PP<br>300FFA6-PP|
## P Performance erformance D Data ata
Typical Insertion Loss — Line to Ground in 50 Ohm circuit
|****||||****|****||||
|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****|
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
230
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**5**
## **DC Feedthrough Filters – Class Y4**
## FFD Series
## Component Recognized by UL to US and Canadian Requirements
## F FFD FD S Series eries
- DC feedthrough filters
- Current ratings from 10 to 200A
- Designed to meet the very stringent safety requirements of EN133200 class Y4 including the 2500V pulse test
- Custom versions available
## O Ordering rdering I Information nformation
## 10 FFD6 – CA
~~L~~ F Filter ilter I ID D See Table F FFD FD S Series eries S Screw crew T Terminals erminals C Current urrent R Rating ating _(in A)_
## F Filter ilter O Options ptions / / S Specifications pecifications
|Filter ID<br>CA<br>HB<br>HE<br>NC<br>ND<br>NH<br>PK<br>RP|Value (nF)<br>2 x 10<br>2 x 100<br>2 x 100<br>2 x 470<br>2 x 470<br>2 x 470<br>2 x 1000<br>2 x 4700|Inductance<br>(nH)<br>70<br>80<br>140<br>90<br>120<br>180<br>240<br>330|DC<br>Resistance<br>(m)Max.<br>6<br>3<br>8<br>2<br>1<br>3<br>2<br>2|
|---|---|---|---|
## S Specifications pecifications
Rated Voltage (max): 130 VDC Rated Current: 10 to 200A Test Voltage (two seconds): 2500 VDC Capacitor Class (EN133200): Designed to meet Y4 Pulse Test (EN133200): 2500V Peak Insulation Resistance (within 1 minute):
For C < 0.33F, R> 15000M For C > 0.33F, RC(M*F)>5000s
Operating Ambient Temperature Range (at rated current Ir):
10 to 100A: -40°C to +60°C 200A: -40°C to +50°C Category Temperature Range: -40°C to +85°C Current Derating Above Ambient: —— 10-100A: For temperature, = R (85-)/25 200A: For temperature, = R (85-)/35 Climatic Category: 40/85/21 MTBF: > 5 million hours typical Insulating Materials Flammability Rating: UL94V-0 Case & Terminal Material: Nickel Plated Brass
E Electrical lectrical S Schematic chematic
231
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**DC Feedthrough Filters – Class Y4** _(continued)_
## FFD Series
**==> picture [235 x 270] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|C|Case|ase S|Style|tyle|
|Resin Fill|T2 (Mounting thread)|
|T1 (Terminal thread)|
|B|C|D|E|F|
||||)|oo|A|||a|
|T1 – Terminal Thread|
|Torque|
|Part No.|Thread|
|max. in.lb.|
|10FFD6-CA/HE|M3|4|
|16FFD6-CA/HE|
|M4|11|
|32FFD6-CA/HE|
|63FFD6-HB/NH|M6|22|
|100FFD6-NC/PK|M8|44|
|200FFD6-ND/RP|M10|70|
**----- End of picture text -----**<br>
## T2 – Mounting Thread
**==> picture [234 x 155] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Torque|
|Part No.|Thread|
|max. in.lb.|
|10FFD6-CA/HE|
|16FFD6-CA/HE|M12 x 1|35|
|32FFD6-CA/HE|
|63FFD6-HB/NH|M20 x 1|89|
|100FFD6-NC/PK|M24 x 1|124|
|200FFD6-ND/RP|M27 x 1.5|142|
**----- End of picture text -----**<br>
## C Case ase D Dimensions imensions
**==> picture [235 x 307] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|A|B|C|D|E|F|
||||||
|Part No.|||||||
|||||||
|10FFD6-CA|
|||||||
|16FFD6-CA|||||||
|32FFD6-CA|||||||
|||||||
|63FFD6-HB|
|||||||
|||||||
|100FFD6-NC|
|||||||
|||||||
|200FFD6-ND|
|||||||
|||||||
|10FFD6-HE|
|||||||
|16FFD6-HE|||||||
|32FFD6-HE|||||||
|||||||
|63FFD6-NH|
|||||||
|||||||
|100FFD6-PK|
|||||||
|||||||
|200FFD6-RP|
|||||||
**----- End of picture text -----**<br>
232
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**5**
## **DC Feedthrough Filters – Class Y4** _(continued)_
## FFD Series
## A Available vailable P Part art N Numbers umbers
Standard Performance High Performance 10FFD6-CA 10FFD6-HE 16FFD6-CA 16FFD6-HE 32FFD6-CA 32FFD6-HE 63FFD6-HB 63FFD6-NH 100FFD6-NC 100FFD6-PK 200FFD6-ND 200FFD6-RP
## P Performance erformance D Data ata
Typical Insertion Loss — Line to Ground in 50 Ohm circuit
|****||||****|****||||
|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****|
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
233
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **AC Feedthrough Capacitors – Class Y2**
## AFC Series
Component Recognized by UL to US and Canadian Requirements
## A AFC FC S Series eries
- AC feedthrough capacitors
- Current ratings from 10 to 300A
- Designed to meet the very stringent safety requirements of EN132400 class Y2 including the 5000V pulse test
- Custom versions available
## O Ordering rdering I Information nformation
## 10 AFC6 – A
- ~~L~~ F Filter ilter I ID D See Table
- A AFC FC S Series eries S Screw crew T Terminals erminals C Current urrent R Rating ating _(in A)_
## F Filter ilter O Options ptions / / S Specifications pecifications
|||Max. Leakage|
|---|---|---|
|Filter ID<br>A|Value (nF)<br>2.2|Current (mA)*<br>0.21|
|B|4.7|0.44|
|C|10|0.94|
|F|33|3.1|
|G|47|4.4|
|H|100|9.4|
|K|220|21|
|N|470|44|
|P|1000|94|
||| |
## S Specifications pecifications
Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 10 to 300A Test Voltage (two seconds): 5000 VDC Capacitor Class (EN132400): Designed to meet Y2 Pulse Test (EN132400): 5000V Peak Insulation Resistance (within 1 minute):
For C < 0.33F, R> 15000M For C > 0.33F, RC(M*F)>5000s
Operating Ambient Temperature Range (at rated current Ir):
10 to 200A: -40°C to +60°C 250 & 300A: -40°C to +40°C Category Temperature Range: -40°C to +85°C Current Derating Above Ambient:
10-200A: For temperature, = R ~~_~~ (85-)/25 250 & 300A: For temp., = R (85-)/45 Climatic Category: 40/85/21 MTBF: > 10 million hours typical Insulating Materials Flammability Rating: UL94V-0 Case & Terminal Material: Nickel Plated Brass
234
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**5**
## **AC Feedthrough Capacitors – Class Y2** _(continued)_
## AFC Series
## C Case ase S Style tyle
## C Case ase D Dimensions imensions
**==> picture [203 x 94] intentionally omitted <==**
**----- Start of picture text -----**<br>
Resin Fill T2 (Mounting thread)<br>T1 (Terminal thread)<br>B C D E F<br>A<br>**----- End of picture text -----**<br>
## T1 – Terminal Thread
|Part No.<br>10AFC6-A/B|Thread<br>M3|Torque<br>max. in.lb.<br>4|
|---|---|---|
|16AFC6-B/C/G/H|||
|20AFC6-B|M4|11|
|32AFC6-B/C/F/G/H|||
|63AFC6-C/G/H|M6|22|
|100AFC6-G/H/K/N<br>200AFC6-H/K/N/P|M8<br>M10|44<br>71|
|250AFC6-H/K/N/P<br>300AFC6-H/K/N/P|M12<br>M16|97<br>177|
## T2 – Mounting Thread
|Part No.<br>10AFC6-A/B<br>16AFC6-B/C/G<br>20AFC6-B<br>32AFC6-B/C/G/F<br>16AFC6-H<br>32AFC6-H<br>63AFC6-C/G/H<br>100AFC6-G/H<br>100AFC6-K/N<br>200AFC6-H/K<br>200AFC6-N/P|Thread<br>M10 x 1<br>M12 x 1<br>M16 x 1<br>M20 x 1<br>M24 x 1<br>M27 x 1.5|Torque<br>max. in.lb.<br>27<br>35<br>62<br>89<br>124<br>142|
|---|---|---|
||A|B|C|D|E|F|
|---|---|---|---|---|---|---|
|Part No.|<br>__|<br>__|<br>__|<br>__|<br>__||
|10AFC6-A|****|****|****|****|****|****|
|10AFC6-B|__|__|__|__|__|__|
|16AFC6-B|****|****|****|****|****|****|
|16AFC6-C|__|__|__|__|__|__|
|16AFC6-G|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|16AFC6-H|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|20AFC6-B|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|32AFC6-B|****|****|****|****|****|****|
|32AFC6-C|__|__|__|__|__|__|
|32AFC6-F|****|****|****|****|****|****|
|32AFC6-G|__|__|__|__|__|__|
|32AFC6-H|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|63AFC6-C|****|****|****|****|****|****|
|63AFC6-G|__|__|__|__|__|__|
|63AFC6-H<br>100AFC6-G<br>100AFC6-H|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|****<br>__<br>****<br>__|
|100AFC6-K<br>200AFC6-H<br>200AFC6-K<br>200AFC6-N<br>200AFC6-P<br>250AFC6-H<br>250AFC6-K<br>250AFC6-N<br>250AFC6-P<br>300AFC6-H<br>300AFC6-K<br>300AFC6-N<br>300AFC6-P|****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__|****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__|****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__|****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__|****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__|****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__<br>****<br>__|
235
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **AC Feedthrough Capacitors – Class Y2** _(continued)_
## AFC Series
## A Available vailable P Part art N Numbers umbers
|10AFC6-A|32AFC6-H|200AFC6-P|
|---|---|---|
|10AFC6-B|63AFC6-C|250AFC6-H|
|16AFC6-B|63AFC6-G|250AFC6-K|
|16AFC6-C|63AFC6-H|250AFC6-N|
|16AFC6-G|100AFC6-H|250AFC6-P|
|16AFC6-H|100AFC6-H|300AFC6-H|
|20AFC6-B|100AFC6-K|300AFC6-K|
|32AFC6-B|100AFC6-N|300AFC6-N|
|32AFC6-C|200AFC6-H|300AFC6-P|
|32AFC6-F|200AFC6-K||
|32AFC6-G|200AFC6-N||
## P Performance erformance D Data ata
Typical Insertion Loss — Line to Ground in 50 Ohm circuit
|****||||****|****||||
|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****|
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
236
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**5**
## **DC Feedthrough Capacitors – Class Y4**
## DFC Series
## Component Recognized by UL to US and Canadian Requirements
## DFC SC S Seriesriesiesess DEC FC SC S Seriesriesiesess Series eriesriesiesess
## DFC SC S Seriesriesiesess
- DC feedthrough capacitors
- Current ratings from 10 to 300A
- Designed to meet the very stringent safety requirements of EN132400 class Y4 including the 2500V pulse test
- Custom versions available
## S Specifications pecifications
Rated Voltage (max): 130 VDC Rated Current: 10 to 300A Test Voltage (two seconds): 2500 VDC Capacitor Class (EN132400): Designed to meet Y4 Pulse Test (EN132400): 2500V Peak Insulation Resistance (within 1 minute):
For C < 0.33F, R> 15000M For C > 0.33F, RC(M*F)>5000s
## O Ordering rdering I Information nformation
10 DFC6 – C ~~L~~ F Filter ilter I ID D See Table D DFC FC S Series eries S Screw crew T Terminals erminals C Current urrent R Rating ating _(in A)_
## F Filter ilter O Options ptions / / S Specifications pecifications
Operating Ambient Temperature Range (at rated current Ir):
10 to 200A: -40°C to +60°C 250 & 300A: -40°C to +40°C Category Temperature Range: -40°C to +85°C Current Derating Above Ambient:
10-200A: For temperature, = R (85-)/25 ~~——_————~~ 250 & 300A: For temp., = R (85-)/45 Climatic Category: 40/85/21 MTBF: > 10 million hours typical Insulating Materials Flammability Rating: UL94V-0 Case & Terminal Material: Nickel Plated Brass
|Filter ID<br>C<br>G<br>H<br>N<br>P<br>Q<br>R<br>T|Value (nF)<br>10<br>47<br>100<br>470<br>1000<br>3300<br>4700<br>8000|
|---|---|
237
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **DC Feedthrough Capacitors – Class Y4** _(continued)_
## DFC Series
## C Case ase S Style tyle
## C Case ase D Dimensions imensions
**==> picture [203 x 94] intentionally omitted <==**
**----- Start of picture text -----**<br>
Resin Fill T2 (Mounting thread)<br>T1 (Terminal thread)<br>B C D E F<br>A<br>**----- End of picture text -----**<br>
## T1 – Terminal Thread
|Part No.|Thread|Torque<br>max. in.lb.|
|---|---|---|
|10DFC6-C|M3|4|
|16DFC6-C/G/H/N<br>32DFC6-C/G/H/N|M4|11|
|63DFC6-C/G/H/N|M6|22|
|100FDC6-G/H/N/P|M8|44|
|200DFC6-H/N/P/R|M10|71|
|250DFC6-P/Q/T|M12|97|
|300DFC6-P/Q/T|M16|177|
## T2 – Mounting Thread
|Part No.|Thread|Torque<br>max. in.lb.|
|---|---|---|
|10DFC6-C|M10 x 1|27|
|16DFC6-C/G/H<br>32DFC6-C/G/H|M12 x 1|35|
|63DFC6-C/G/H|M16 x 1|62|
|16DFC6-N|||
|32DFC6-N|M20 x 1|89|
|63DFC6-N|||
|100DFC6-G/H/N|||
|100DFC6-P<br>200DFC6-H/N/P|M24 x 1|124|
|200FFC6-R|M27 x 1.5|142|
||A|B|C|D|E|F|
|---|---|---|---|---|---|---|
|Part No.|<br>__|<br>__|<br>__|<br>__|<br>__||
|10DFC6-C|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|16DFC6-C|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|16DFC6-G|****|****|****|****|****|****|
|16DFC6-H|__|__|__|__|__|__|
|16DFC6-N|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|32DFC6-C|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|32DFC6-G|****|****|****|****|****|****|
|32DFC6-H|__|__|__|__|__|__|
|32DFC6-N|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|63DFC6-C<br>63DFC6-G<br>63DFC6-H|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|63DFC6-N|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|100DFC6-G<br>100DFC6-H<br>100DFC6-N|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|100DFC6-P|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|200DFC6-H|****|****|****|****|****|****|
|200DFC6-N|__|__|__|__|__|__|
|200DFC6-P|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|200DFC6-R|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|****<br>__|
|250DFC6-P|****|****|****|****|****|****|
|300DFC6-P|__|__|__|__|__|__|
|250DFC6-Q|****|****|****|****|****|****|
|300DFC6-Q|__|__|__|__|__|__|
|250DFC6-T|****|****|****|****|****|****|
|300DFC6-T|__|__|__|__|__|__|
238
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**5**
## **DC Feedthrough Capacitors – Class Y4** _(continued)_
## DFC Series
## A Available vailable P Part art N Numbers umbers
|10DFC6-C|32DFC6-H|100DFC6-H|250DFC6-P|
|---|---|---|---|
|16DFC6-C|32DFC6-N|100DFC6-N|250DFC6-Q|
|16DFC6-G|63DFC6-C|100DFC6-P|250DFC6-T|
|16DFC6-H|63DFC6-G|200DFC6-H|300DFC6-P|
|16DFC6-N|63DFC6-H|200DFC6-N|300DFC6-Q|
|32DFC6-C|63DFC6-N|200DFC6-P|300DFC6-T|
|32DFC6-G|100DFC6-G|200DFC6-R||
## P Performance erformance D Data ata
Typical Insertion Loss — Line to Ground in 50 Ohm circuit
|****||||****|****||||
|---|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|****|
||||||||||
||||||||||
||||||||||
||||||||||
|<br>|<br>|<br>|<br>|<br>|<br>|<br>|<br>|<br>|
||||||||||
||||||||||
239
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Engineering Notes**
240
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**6**
## **6. Signal Line Products — Table of Contents**
|I<br>n<br>t<br>r<br>o<br>d<br>u<br>c<br>t<br>i<br>o<br>n<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>4<br>2<br>INCFOCUCTION<br>2... ccc cece cece cece cee<br>r ccc ersecesececsrecsssecsrsess<br>d4d|
|---|
|S<br>i<br>g<br>n<br>a<br>l<br>S<br>e<br>n<br>t<br>r<br>y<br>F<br>i<br>l<br>t<br>e<br>r<br>e<br>d<br>M<br>o<br>d<br>u<br>l<br>a<br>r<br>J<br>a<br>c<br>k<br>s<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>4<br>3<br>SignalSentry Filtered Modular Jacks ........c0cccccccesccessevesss<br>D4S|
|S<br>i<br>g<br>n<br>a<br>l<br>S<br>e<br>n<br>t<br>r<br>y<br>P<br>r<br>o<br>d<br>u<br>c<br>t<br>P<br>a<br>r<br>t<br>N<br>u<br>m<br>b<br>e<br>r<br>M<br>a<br>t<br>r<br>i<br>x<br>/<br>O<br>r<br>d<br>e<br>r<br>i<br>n<br>g<br>I<br>n<br>f<br>o<br>r<br>m<br>a<br>t<br>i<br>o<br>n<br>.<br>.<br>.<br>.<br>2<br>4<br>4<br>SignalSentry Product Part NumberMatrix<br>/ Ordering Information ....244|
|S<br>i<br>g<br>n<br>a<br>l<br>S<br>e<br>n<br>t<br>r<br>y<br>P<br>r<br>o<br>d<br>u<br>c<br>t<br>S<br>e<br>l<br>e<br>c<br>t<br>o<br>r<br>C<br>h<br>a<br>r<br>t<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>4<br>5<br>SignalSen**t**ry<br>Product Selec or Chart ........0cceccccesccvssevcsss<br>245|
|L Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .247|
|L – Ganged Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248|
|LC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .249|
|LCT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250|
|N Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .251|
|X Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .252|
|Z Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253|
|M<br>o<br>d<br>e<br>l<br>D<br>i<br>m<br>e<br>n<br>s<br>i<br>o<br>n<br>s<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>.<br>2<br>5<br>5<br>Model DIMENSIONS ......00ccccccsccccccccescecscseccescecsssseess<br>DOD|
|L, LC, LCT and X Series RJ Jack Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255|
|N and Z Series RJ Jack Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .257|
241
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Introduction**
Corcom brand SignalSentry filtered modular jack series product combines different levels of filtering with RJ45 and RJ11 modular jacks to solve signal line noise problems and crosstalk.
Corcom brand SignalSentry filtered modular jack series product has expanded into 80 different products for filtering the signal line, including inductor and capacitor, shielded, ganged, low profile and surface mountable versions. Designs not only save valuable panel space, but also place the filtering elements where they can be most effective in eliminating RFI.
The L and N series RJ11 and RJ45 jacks offer filtering with inductance and optional shielding, while the LC and LCT series combine inductance with 82pF or 820pF capacitors. The X and Z series complete the offering with unfiltered versions of our standard profile and low profile jacks.
Use the selector chart to combine your filtering performance with the RJ11 or RJ45 jacks. Mechanical dimensions are listed following the series information.
For the latest information and additional technical articles, find Corcom products on the Internet at www.corcom.com.
242
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**6**
## **SignalSentry Filtered Modular Jacks**
Corcom brand SignalSentry filtered modular jacks are a space saving and cost-effective solution to RFI problems on signal lines. Its inductive and optional capacitive elements effectively strip common-mode noise from the incoming signal, and at the same time limit the signal line’s ability to radiate emissions like an antenna.
The SignalSentry filtered modular jack series has expanded into 80 different products for filtering the signal line, including inductor and capacitor, shielded, ganged, low profile and surface mountable versions. Filtered RJ jacks provide interference suppression at the optimal location by integrating the filtering into the RJ jack itself. Our new ganged jacks are the only RJ11 filtered ganged jacks available in the market.
SignalSentry filtered modular jack products are useful for any electronic equipment that sends or receives data on unshielded twisted pair or other multi-conductor cabling systems. Modems, PBX’s, LAN, ISDN, and local I/O interfaces that use RJ connectors are all candidates.
Jack design and component selection compatible with equipment registered under FCC part 68.
## Applications
A fax/modem board was being certified for FCC Class B emissions at an independent test laboratory. The board caused every computer it was tested in to exceed the radiated limits above 30 MHz, at multiples of each microprocessor’s clock frequency, on the telephone line. The test lab replaced the modem’s unfiltered RJ11 jack with a C Corcom orcom R RJTI J11 ~~i -~~ -4 4L ~~L-~~ B B filtered modular jack out of their sample kit, and the board/computer combinations passed with 4 dB margin worst case.
An RISC workstation designed to operate in a twisted-pair Local Area Network required two DIP package inductors and 12 chip capacitors to meet FCC radiated emissions limits. All 14 discrete components were eliminated by replacing the two RJ45 connectors with two Corcom { sdeol. i RJ45 ~~-~~ 8LC1 ~~-~~ B shielded and filtered Corcom 0 PS) ff | Rv45 ~~-s~~ ici ~~-~~ 8 ? jacks, and the margin of compliance ’ i actually improved.
UL Recognized
CSA Certified
A secure telephone set failed hardened application testing at a government facility, due to intelligible emanations radiated from the coiled handset cord. The unit passed after the handset connector in the desk set was replaced by a C Corcom orcom R RJH JH ~~-~~ 4 4L L ~~-~~ B B filtered handset jack.
A medical manufacturer was designing a heart monitor which aE x[&] ~~ would transfer data over a signal line to the nurses’ station so they could { | monitor patients. When the doctors used their modems, the data coming from the monitor became distorted. This occurred due to the close proximity of the modem card and monitor communication card placed next to each other. A C Corcom orcom l low ow p profile rofile R RJ45 J45 ~~-~~ 8 8N3 N3 ~~-~~ B B modular jack was designed in to filter out the unwanted noise.
243
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **SignalSentry Part Number Matrix / Ordering Information**
## WHAT TYPE OF CONNECTOR DO YOU NEED?
Handset jack four pin connector RJH **RJ11** RJ11 six pin connector RJ11 RJ45 eight pin connector RJ45 HOW MANY TERMINALS WILL BE LOADED? 4 on RJH ~~ee~~ **4** 2, 4 or 6 on RJ11 6 or 8 on RJ45 WHAT LEVEL OF FILTERING PERFORMANCE DO YOU NEED? No filter, standard profile X models Inductor (block or sleeve), standard profile L models Inductor plus capacitors with shield LC models iL’ **L** Inductor, 82 pF cap. and shield LCT model Inductor (block or sleeve), low profile N models No filter, low profile Z models
DO YOU WANT A SHIELDED JACK?
## WHAT TYPE OF GROUND?
1Panel and board ground (spring fingers on panel interface) 1 1Board ground pins only 2 2Panel, board and cable ground (low profile versions) 3 1- **1** 2Board ground and cable ground (low profile versions) 4
WHAT TYPE OF INDUCTORS DO YOU NEED? ~~Oe~~ Sleeve — Average performance S **B** Block — Higher performance B RJ11 Model Contact Loading Program RJ45 Model Contact Loading Program 1 2 3 4 5 6 1 2 3 4 5 6 7 8 ~~eo~~ ee Lead Frame Position Lead Frame Position Jack Designation Jack Designation 1 2 3 4 5 6 1 2 3 4 5 6 7 8 RJ11 – 2 ** ** RJ45 – 6 ** ** RJ11 – 4 ** ** RJ45 – 8 ** ** RJ11 – 6 ** **
244
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help**
**corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**6**
## **SignalSentry Selector Chart**
**==> picture [373 x 407] intentionally omitted <==**
**----- Start of picture text -----**<br>
Yes Filtered No<br>Try The<br>X<br>Series<br>Standard Profile<br>Level Modular Jack<br>Page 252<br>of Filtering<br>Z<br>Series<br>Inductor Inductor<br>Low Profile<br>and Capacitor Only Modular Jack<br>Page 253<br>ot<br>Ganged<br>Jacks<br>Try The<br>LC Yes No<br>Series<br>820pF<br>Modular Jack<br>Page 249 Try The Try The<br>LCT L (Ganged) L<br>Series Series Series<br>82pF Standard Profile Standard Profile<br>Modular Jack Modular Jack Modular Jack<br>Page 250 Page 248 Page 247<br>N<br>Series<br>Low Profile<br>Modular Jack<br>Page 251<br>**----- End of picture text -----**<br>
245
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Engineering Notes**
246
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**6**
## **Inductive Filtering Modular RJ Jacks**
## L Series
UL Recognized CSA Certified
**==> picture [185 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
RJ11 RJ11 with RJ45 with RJ45<br>Block Filter Sleeve Filter<br>**----- End of picture text -----**<br>
## L L S Series eries
- Inductive filtering in standard RJ11, RJ45, or handset jacks.
- Available with standard ferrite sleeve inductors or higher performance ferrite blocks
- Available unshielded or shielded with board grounded shield or spring fingered panel ground interface
## A Available vailable P Part art N Numbers umbers
|able P<br>ble P<br>le P<br>e P<br>P<br>art N<br>rt N<br>t N<br>N<br>umbers<br>mbers<br>bers<br>ers<br>rs<br>s<br>Available Part Numbers|able P<br>ble P<br>le P<br>e P<br>P<br>art N<br>rt N<br>t N<br>N<br>umbers<br>mbers<br>bers<br>ers<br>rs<br>s<br>Available Part Numbers|
|---|---|
|Inductor Filter||
|RJH-4L-B|RJ45-6L-S|
|RJ11-2L-S|RJ45-6L-B|
|RJ11-2L-B|RJ45-8L-S|
|RJ11-4L-S|RJ45-8L-B|
|RJ11-4L-B<br>RJ11-6L-S||
|RJ11-6L-B||
|Inductor Filter and Shield<br>RJ11-2L2-B<br>RJ45-6L1-S<br>RJ11-4L1-S<br>RJ45-6L1-B<br>RJ11-4L1-B<br>RJ45-6L2-S<br>RJ11-4L2-S<br>RJ45-6L2-B<br>RJ11-4L2-B<br>RJ45-8L1-S<br>RJ11-6L1-S<br>RJ45-8L1-B<br>RJ11-6L1-B<br>RJ45-8L2-S<br>RJ11-6L2-S<br>RJ45-8L2-B<br>RJ11-6L2-B||
## S Specifications pecifications
Contacts: Material: Phosphor Bronze Plating: 50 microinches gold Barrier underplating: 100 microinches nickel Resistance: Initial: 20 m max. After 500 mating cycles: 30 m max.
Ferrites: Type: High resistivity, nickel zinc ceramic Sleeves: Single-aperture cylinders Block: Multi-aperture rectangular prism Shield Material: Tin-plated copper alloy Housing Material: Glass-filled polyester (UL94V-0) Dielectric Withstanding Voltage: Line to Line and Line to Ground: 1000 VAC for 60 seconds
Printed Circuit Board Retention: Before soldering: 1 lb. minimum After soldering: 20 lb. minimum
## T Typical ypical I Impedance mpedance i in n O Ohms hms
**==> picture [144 x 150] intentionally omitted <==**
**----- Start of picture text -----**<br>
140150 [|<br>130 [| | 7 7<br>120 LC | 74[|1\ _<br>100 110 a[Iz<br>90 ry ee| |; \_]<br>80 [ye<br>70 CL 7 || mn| _\I\ 1<br>6050 aLZ|ra a<br>40 ey TV i<br>30 [7 7- aa | ee|<br>20 Z7 i, | | V<br>10 v7;| | |<br>0 ZY;| |<br>1 25 100 200 500<br>Frequency in MHz<br>Ferrite block<br>Ferrite sleeve<br>Impedance in Ohms<br>**----- End of picture text -----**<br>
**==> picture [196 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Shield 2 Shield 1<br>**----- End of picture text -----**<br>
Model dimensions and PC board layout on pages 255-259
247
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Inductive Filtering Ganged Modular RJ Jacks**
## L – Ganged Series
## UL Recognized CSA Certified
**==> picture [209 x 54] intentionally omitted <==**
**----- Start of picture text -----**<br>
4RJ11<br>6RJ11 |<br>‘ a?<br>ae 2RJ11 with Block Filter -<br>**----- End of picture text -----**<br>
## L L= ~~– -~~ G Ganged anged S Series eries
- Ganged version of our L Series filtered jacks
- Available in RJ11 models with block inductors
- Available in gangs of 2, 4 or 6
- Retrofits existing unfiltered ganged jack footprints
## D Dimensions imensions a and nd P PC C B Board oard L Layout ayout
**==> picture [243 x 331] intentionally omitted <==**
**----- Start of picture text -----**<br>
A .050<br>.470 1.27<br>11.94<br>T — ee<br>hog(<br>C r m w a ar inn’ — ton er<br>k e B<br>C<br>8.25 .325 .050 [ 1.27 ] 2.54 .100 .030 [+ .008] - .003 [Dia.]<br>.250 .350 [ 8.89 ]<br> [ 6.35 ]<br>.128 + .003 Dia.<br>f ) D aa<br>.810<br>20.57<br>— [<br>.590<br>14.99 —__ .040 1.02<br>.195<br>mm = TI 4<br>pf? .410 4 .165<br>10.41 — 4.19<br>a<br>Oe Ports A B C D<br> <br>2<br>oo <br> <br>4<br>OO sm <br>6<br> <br>**----- End of picture text -----**<br>
## S Specifications pecifications
Contacts:
Material: Phosphor Bronze Plating: 50 microinches gold Barrier underplating: 100 microinches nickel Resistance: Initial: 20 m max. After 500 mating cycles: 30 m max.
Ferrites: Type: High resistivity, nickel zinc ceramic Block: Multi-aperture rectangular prism Housing Material: Glass-filled polyester (UL94V-0)
Dielectric Withstanding Voltage:
Line to Line and Line to Ground: 1000 VAC for 60 seconds
Printed Circuit Board Retention:
Before soldering: 1 lb. minimum After soldering: 20 lb. minimum
Available Part Numbers 2RJ11-6L-B 4RJ11-6L-B Available Part ~~Numbers~~ 6RJ11-6L-B
**==> picture [193 x 156] intentionally omitted <==**
**----- Start of picture text -----**<br>
T Typical ypical I Impedance mpedance i in n O Olms hms<br>150<br>140 es ee a ae<br>130 es es ee<br>120 re ee ee<br> 110 ee ae ee<br>100<br>90 Aey ee ee<br>80 ey eeee<br>70 ey 6 ee ee<br>60<br>50 2oy ee en<br>4030 >>|se ee<br>20<br>10 r e e reee ee<br>0 |<br>1 25 100 200 500<br>Frequency in MHz<br>Impedance in Ohms<br>**----- End of picture text -----**<br>
248
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**6**
## **Filtered Modular Jacks with Enhanced Performance**
## LC Series
## WG UL Recognized CSA Certified
**==> picture [209 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
Shield 2 Shield 1 Shield 2 Shield 1<br>RJ11 RJ11 RJ45 RJ45<br>**----- End of picture text -----**<br>
## LC S Seriesriesiesess LC C S Seriesriesiesess Series eriesriesiesess
## LC S Seriesriesiesess
- Chip capacitors provide enhanced filtering performance on each line
- Available with block or sleeve inductance
- Available with board grounded shield or spring fingered panel ground interface
## S Specifications pecifications
Contacts:
Material: Phosphor Bronze Plating: 50 microinches gold Barrier underplating: 100 microinches nickel Resistance: Initial: 20 m max. After 500 mating cycles: 30 m max.
Capacitors:
## P Performance erformance D Data ata
## Typical Insertion Loss
##
||||****|****||
|---|---|---|---|---|---|
|****<br>**** |****<br>|****<br>|****<br>****<br>****<br><br><br>|****<br>|****<br>|
|**** |||<br><br>|||
|||||||
||||****|||
|****|****|****|****<br>****<br>****|****|****|
|**** <br><br><br><br><br><br><br><br>~~|~~||||||
|**** |||<br><br>|||
Model dimensions and PC board layout on pages 255-259
Type: Monolithic ceramic chip Standard Value: 820 pF Standard Tolerance: ± 20%
## Ferrites:
Type: High resistivity, nickel zinc ceramic Sleeves: Single-aperture cylinders Block: Multi-aperture rectangular prism Shield Material: Tin-plated copper alloy Housing Material: Glass-filled polyester (UL94V-0)
Dielectric Withstanding Voltage:
Line to Line and Line to Ground: 1000 VAC for 60 seconds Printed Circuit Board Retention: Before soldering: 1 lb. minimum After soldering: 20 lb. minimum
Printed Circuit Board Retention:
## A Available vailable P Part art N Numbers umbers
|RJ11-2LC1-S<br>RJ11-2LC1-B<br>RJ11-2LC2-S<br>RJ11-2LC2-B<br>RJ11-4LC1-S<br>RJ11-4LC1-B<br>RJ11-4LC2-S<br>RJ11-4LC2-B<br>RJ11-6LC1-S<br>RJ11-6LC1-B|RJ11-6LC2-S<br>RJ11-6LC2-B<br>RJ45-6LC1-S<br>RJ45-6LC1-B<br>RJ45-6LC2-S<br>RJ45-6LC2-B<br>RJ45-8LC1-S<br>RJ45-8LC1-B<br>RJ45-8LC2-S<br>RJ45-8LC2-B|
|---|---|
249
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Low Capacitance Modular RJ Jacks**
## LCT Series
UL Recognized CSA Certified
**==> picture [209 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
Shield 2 Shield 1 Shield 2 Shield 1<br>RJ11 RJ11 RJ45 RJ45<br>**----- End of picture text -----**<br>
## L LCT CT S Series eries
- Low capacitance model for improved performance.
- Particularly suited for ethernet applications
- Available with block or sleeve inductance
- Available with board grounded shield or spring fingered panel ground interface
## P Performance erformance D Data ata
## Typical Insertion Loss
##
||||****|****|****|||
|---|---|---|---|---|---|---|---|
|****<br>**** |****<br>|****<br>|****<br>|****<br>|****<br>|****<br>|****<br>|
|**** ||||||||
##
||||****|****|****|||
|---|---|---|---|---|---|---|---|
|****|****|****|****|****|****|****|****|
|**** ||||||||
|**** ||||||||
## S Specifications pecifications
Contacts:
Material: Phosphor Bronze Plating: 50 microinches gold Barrier underplating: 100 microinches nickel Resistance: Initial: 20 m max. After 500 mating cycles: 30 m max.
Capacitors:
Type: Monolithic ceramic chip Standard Value: 82 pF Standard Tolerance: ± 20%
## Ferrites:
Type: High resistivity, nickel zinc ceramic Sleeves: Single-aperture cylinders Block: Multi-aperture rectangular prism Shield Material: Tin-plated copper alloy Housing Material: Glass-filled polyester (UL94V-0)
Dielectric Withstanding Voltage:
Line to Line and Line to Ground: 1000 VAC for 60 seconds Printed Circuit Board Retention: Before soldering: 1 lb. minimum After soldering: 20 lb. minimum
Printed Circuit Board Retention:
## A Available vailable P Part art N Numbers umbers
|RJ11-6LCT1-S|RJ45-8LCT1-S|
|---|---|
|RJ11-6LCT1-B|RJ45-8LCT1-B|
|RJ11-6LCT2-S|RJ45-8LCT2-S|
|RJ11-6LCT2-B|RJ45-8LCT2-B|
Model dimensions and PC board layout on pages 255-259
250
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**6**
## **Low Profile Filtered Modular Jacks**
## N Series
## UL Recognized CSA Certified
**==> picture [117 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
Shield 3<br>RJ11<br>Shield 4<br>RJ45<br>**----- End of picture text -----**<br>
## N Seriesriesiesess N Seriesriesiesess Series eriesriesiesess
## N Seriesriesiesess
- Low profile SignalSentry filtered jack
- Available with sleeve or block inductors
- Available unshielded or shielded with board grounded shield or spring fingered panel ground interface
## S Specifications pecifications
Contacts:
Material: Phosphor Bronze Plating: 50 microinches gold Barrier underplating: 100 microinches nickel Resistance: Initial: 20 m max. After 500 mating cycles: 30 m max.
Ferrites:
## T Typical ypical I Impedance mpedance i in n O Ohms hms
**==> picture [165 x 125] intentionally omitted <==**
**----- Start of picture text -----**<br>
100<br>90<br>80 P| eeYlee ee eee<br>70 P| [ff [f] NS<br>60 ee<br>50 ff ftee ee ee<br>40 aeeee ee<br>30 S|<br>20 [Jf xm ][<br>10 a<br>0 7 | | ee| ee{| ee|<br>1 25 100 200 500 1000<br>Frequency in MHz<br>Ferrite block Ferrite sleeve<br>Impedance in Ohms<br>**----- End of picture text -----**<br>
Type: High resistivity, nickel zinc ceramic Sleeves: Single-aperture cylinders Block: Multi-aperture rectangular prism Shield Material: Tin-plated copper alloy
Housing Material: Black glass-filled polyamide (STANYL TE250F3)
## Dielectric Withstanding Voltage:
Line to Line and Line to Ground: 1000 VAC for 60 seconds
Printed Circuit Board Retention:
Before soldering: 1 lb. minimum After soldering: 20 lb. minimum
## A Available vailable P Part art N Numbers umbers
|RJ11-6N-B<br>RJ11-6N3-B<br>RJ11-6N4-B|RJ45-8N-B<br>RJ45-8N-S<br>RJ45-8N3-B<br>RJ45-8N3-S<br>RJ45-8N4-B<br>RJ45-8N4-S|
|---|---|
**==> picture [45 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
Unshielded<br>Ferrite Block<br>**----- End of picture text -----**<br>
Model dimensions and PC board layout on pages 255-259
251
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Unfiltered Modular Jacks**
## X Series
UL Recognized CSA Certified
**==> picture [93 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
RJ45 RJ11<br>**----- End of picture text -----**<br>
## X X S Series eries
- Unfiltered standard jack
- RJ11 or RJ45
- 2, 4, 6 or 8 loaded contacts
- Available unshielded or shielded with board grounded shield or spring fingered panel ground interface
## S Specifications pecifications
Contacts: Material: Phosphor Bronze Plating: 50 microinches gold Barrier underplating: 100 microinches nickel Resistance:
Initial: 20 m max. After 500 mating cycles: 30 m max.
Shield Material: Tin-plated copper alloy
Housing Material: Glass-filled polyester (UL94V-0)
Dielectric Withstanding Voltage: Line to Line and Line to Ground: 1000 VAC for 60 seconds
## Printed Circuit Board Retention:
Before soldering: 1 lb. minimum After soldering: 20 lb. minimum
_Shield 1 Shield 2_
## A Available vailable P Part art N Numbers umbers
|RJ11-2X<br>RJ11-4X<br>RJ11-6X|RJ45-6X<br>RJ45-8X<br>RJ45-8X1<br>RJ45-8X2|
|---|---|
Model dimensions and PC board layout on pages 255-259
252
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**6**
## **Low Profile Unfiltered Modular Jacks**
## Z Series
UL Recognized CSA Certified
**==> picture [110 x 18] intentionally omitted <==**
**----- Start of picture text -----**<br>
Shield 3 Shield 4<br>RJ11 RJ45<br>**----- End of picture text -----**<br>
## Z Z S Series eries
- Low profile
- Unfiltered
- Available unshielded or shielded with board grounded shield or spring fingered panel ground interface
## S Specifications pecifications
Contacts:
Material: Phosphor Bronze Plating: 50 microinches gold Barrier underplating: 100 microinches nickel Resistance: Initial: 20 m max. After 500 mating cycles: 30 m max.
Shield Material: Tin-plated copper alloy Housing Material: Black glass-filled polyester (VALOX 457)
## A Available vailable P Part art N Numbers umbers
|RJ11-6Z|RJ45-8Z|
|---|---|
|RJ11-6Z3|RJ45-8Z3|
|RJ11-6Z4|RJ45-8Z4|
Dielectric Withstanding Voltage: Line to Line and Line to Ground: 1000 VAC for 60 seconds
Printed Circuit Board Retention: Before soldering: 1 lb. minimum After soldering: 20 lb. minimum
Model dimensions and PC board layout on pages 255-259
253
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Engineering Notes**
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**6**
## **Model Dimensions**
## L L, , L LC, C, L LCT CT a and nd X X S Series eries R RJ J J Jack ack D Dimensions imensions
**==> picture [490 x 263] intentionally omitted <==**
**----- Start of picture text -----**<br>
RJ11 – No Shield RJ11 – Style 2 Shield<br>.900<br>.620 .810 22.86<br>15.75 20.57 .800<br>.520 20.32<br>13.21<br>— e e<br>14.99 .590 19.81 .780<br>.040 1.02 1.02 .04<br>e o L e<br>.195 4.95 .165 4.19 .195 4.95 .165 4.19 .165 4.19<br>i u m H y T cS Sh i n a [FE<br>.322 .395<br>8.19 10.03<br>.322 .485<br>YT hp 8.18 12.32<br>6<br>4 53 13.21 .520 64 5 .540<br>2 3 13.72<br>1 2<br>1<br>ee ] et<br>ol E=F h<br>Part No. Part No.<br>RJ11-2L-S RJ11-2L-B RJ11-2X RJ11-2LC2-S RJ11-2LC2-B RJ11-4L2-S RJ11-6L2-B<br>RJ11-4L-S RJ11-4L-B RJ11-4X RJ11-4LC2-S RJ11-4LC2-B RJ11-6L2-S RJ11-6LCT2-S<br>RJ11-6L-S RJ11-6L-B RJ11-6X RJ11-6LC2-S RJ11-6LC2-B RJ11-4L2-B RJ11-6LCT2-B<br>**----- End of picture text -----**<br>
RJ11 – Style 1 Shield
**==> picture [142 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
RJ11 – PC Board Layout<br>**----- End of picture text -----**<br>
**==> picture [493 x 254] intentionally omitted <==**
**----- Start of picture text -----**<br>
.900<br>21.34 .840 22.86 .860 With shield<br>21.84 .350<br>8.89<br>.322 .250<br>8.18 6.35 0.76 ± .003<br>1.93 ± .08<br>.780<br>19.81<br>0.030 +.008 / -.003<br>.04 .76 +.20 / - .08<br>a +3 1.02 oe | (6 places)<br>.195 .165 .165 1<br>fe= 4.95 4.19 |)1 4.19 .400 A ! 2 e _ 3<br>10.16 4<br>5<br>6<br>a n .322 .485 | 7 ° of —_} __}<br>8.18 12.32 .050<br>Sn ns -= .075 1.27 _<br>6 .075 1.91 (5 places)<br>5 1.91<br>4 .540<br>3 13.72<br>2 1 .128 ± .003 Dia.<br>.210 .345 3.25 ± .08<br>er y IN—<br>5.33 8.76 (2 holes)<br>|Raion Sie — | Ls ——<br>Part No. For all RJ11 L, LC, LCT and X Series Models<br>RJ11-2LC1-S RJ11-2LC1-B RJ11-4L1-S RJ11-6L1-B Shown from Component Side<br>RJ11-4LC1-S RJ11-4LC1-B RJ11-6L1-S RJ11-6LCT1-S<br>RJ11-6LC1-S RJ11-6LC1-B RJ11-4L1-B RJ11-6LCT1-B<br>Edge of Board<br>**----- End of picture text -----**<br>
__
255
255
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Model Dimensions** _(continued)_
## L L, , L LC, C, L LCT CT a and nd X X S Series eries R RJ J J Jack ack D Dimensions imensions _(continued)_
## RJ45 – No Shield
**==> picture [128 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
RJ45 – Style 2 Shield<br>**----- End of picture text -----**<br>
**==> picture [480 x 247] intentionally omitted <==**
**----- Start of picture text -----**<br>
.700 .900<br>17.78 .810 22.86<br>.600 20.57 .800<br>15.24 20.32<br>— ot ————<br>tT |non]non] | [<br>.540 .780<br>13.72 19.81<br>.04<br>1.02 .04<br>1.02<br>.195 4.95 .165 4.19 .195 4.95 .165 4.19 .165 4.19<br>Ug t a ) tar EL 1 E<br>.322 .395<br>8.18 10.03<br>.322 .485<br>8.18 12.32<br>rT nee<br>8<br>7 8<br>6 7<br>5 6<br>3 4 5 4 .620<br>2 3 2<br>1 1<br>a T°i l Jtaa ioanoan t<br>Part No. Part No.<br>RJ45-6L-S RJ45-8L-B RJ45-6LC2-S RJ45-8LC2-S RJ45-6LC2-B RJ45-8LC2-B<br>RJ45-8L-S RJ45-6X RJ45-6L2-S RJ45-8L2-S RJ45-6L2-B RJ45-8L2-B<br>RJ45-6L-B RJ45-8X RJ45-8LCT2-S RJ45-8LCT2-B<br>**----- End of picture text -----**<br>
**==> picture [236 x 247] intentionally omitted <==**
**----- Start of picture text -----**<br>
.900<br>22.86<br>.800<br>20.32<br>————<br>|non]non] | [<br>.780<br>19.81<br>.04<br>1.02<br>.195 .165 .165<br>4.95 4.19 4.19<br>tar EL 1 E<br>.322 .485<br>8.18 12.32<br>nee<br>8<br>7<br>6<br>5 .620<br>4 15.75<br>3<br>2<br>1<br>Jtaa ioanoan t re<br>Part No.<br>RJ45-6LC2-S RJ45-8LC2-S RJ45-6LC2-B RJ45-8LC2-B<br>RJ45-6L2-S RJ45-8L2-S RJ45-6L2-B RJ45-8L2-B<br>RJ45-8LCT2-S RJ45-8LCT2-B<br>**----- End of picture text -----**<br>
## RJ45 – Style 1 Shield
**==> picture [226 x 258] intentionally omitted <==**
**----- Start of picture text -----**<br>
.900<br>.920 22.86<br>23.37 .860<br>21.84<br>fo —_———<br>Gnnn x<br>.780<br>19.81<br>.04<br>1.02<br>cae | - |<br>.195 .165 .165<br>4.95 4.19 4.19<br>Trani —= .322 .485 =<br>8.18 12.32<br>8<br>7<br>6<br>5 .620<br>4 15.75<br>3<br>2<br>1<br>Part No.<br>RJ45-6LC1-S RJ45-8LC1-S RJ45-6LC1-B<br>RJ45-6L1-S RJ45-8L1-S RJ45-6L1-B<br>RJ45-8LCT1-S RJ45-8LCT1-B RJ45-8LC1-B<br>RJ45-8L1-B<br>**----- End of picture text -----**<br>
## RJ45 – PC Board Layout
**==> picture [194 x 152] intentionally omitted <==**
**----- Start of picture text -----**<br>
.322 .350 .076±.003 Dia.<br>8.18 8.89 1.93±.08<br>_ .250 6.35 _ a (4 PLACES)<br>.030 +.008/.003 [Dia.]<br>. 76 +.20/-.08<br>1 (8 PLACES)<br>2<br>i a 3 d<br>.450 4 .050<br>11.43 5 1.27<br>6 (7 SPACES)<br>7<br>7 . 8 ! _<br>.050 .090<br>.210 .345 1.27 2.29<br>5.33 8.76 .128±.003 Dia.<br>3.25±.08<br>(4 PLACES)<br>**----- End of picture text -----**<br>
For all RJ45 L, LC, LCT and X Series Models Shown from Component Side
__
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**6**
## **Model Dimensions** _(continued)_
## L L, , L LC, C, L LCT CT a and nd X X S Series eries R RJ J J Jack ack D Dimensions imensions _(continued)_
## RJH – No Shield
## RJH – PC Board Layout
**==> picture [477 x 227] intentionally omitted <==**
**----- Start of picture text -----**<br>
.540 .810<br>13.72 20.57<br>.440<br>a 11.18 rT<br>.322 .350<br>8.18 8.89<br>14.99 .590 .250 6.35 .030 +.008/ .76 +20/-.08 -.003 Dia.<br>1.02 .04 (4 holes)<br>.195 1<br>“ Ur n 4.95 l t .300 7 | 2<br>a TI 7.62 _ _ 3 ty<br>4<br>.322 .395<br>8.18 10.03 .050<br>a ~~] - S S a .075 1.27 __<br>1.91 (3 Spaces)<br>4<br>3 2 ~ .128±.003 : Dia.<br>1 ° 3.25±.08<br>(2 holes)<br>.250<br>a 6.35 .350 ee<br>8.89<br>Part No.<br>RJH-4-L-B<br>Edge of board<br>**----- End of picture text -----**<br>
## N N a and nd Z Z S Series eries R RJ J J Jack ack D Dimensions imensions
## RJ11 – Low Profile, No Shield
RJ11 Low Profile, Style 3 Shield
**==> picture [492 x 234] intentionally omitted <==**
**----- Start of picture text -----**<br>
15.75 .620.520 18.03 .710 23.11 .910 Max. 18.80 .740<br>13.21<br>— Po —<br>.515*<br>.485 13.08<br>12.32 .010<br>.010 .25<br>.25<br>.165 Ly 4 .135 tata ye .120 3.05 .135 3.43 .165 4.19<br>4.19 3.43 *to top of shield<br>| —<br>o t } H — F 4 i “ ” fo —<br>.217 .430<br>.217 .400 5.51 10.92<br>5.51 10.16<br>6<br>Ft th 5<br>6 4 .550<br>5 3 13.97<br>4 .520 2<br>3 13.21 1<br>2<br>O f 1 = : I<br>= n pa il<br>Part No. Part No.<br>0 RJ11-6N-B RJ11-6Z RJ11-6N3-B RJ11-6Z3<br>**----- End of picture text -----**<br>
**==> picture [152 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
<br>**----- End of picture text -----**<br>
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
257
257
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Model Dimensions** _(continued)_
## N N a and nd Z Z S Series eries R RJ J J Jack ack D Dimensions imensions _(continued)_
**==> picture [473 x 245] intentionally omitted <==**
**----- Start of picture text -----**<br>
RJ11 Low Profile, Style 4 Shield RJ45 – Low Profile, No Shield<br>.620 .740 .70 .710<br>15.75 18.80 17.78 18.03<br>.60<br>15.24<br>| .515* | eq .485<br>13.08 12.32 .010<br>.254<br>al .120 Ld .010 .135 .165 al l i e<br>3.05 .25 3.43 4.19 .135 .165<br>3.5 4.2<br>STMT — *to top of shield —/ET => re<br>.217 .430<br>5.51 10.92 .217 .40<br>5.51 10.16<br>oe Wo<br>6<br>5<br>4 .550<br>3 13.97<br>2<br>1<br>=eSe t| fae<br>Part No. Part No.<br>eS RJ11-6N4-B RJ11-6Z4 RJ45-8N-B RJ45-8N-S RJ45-8Z<br>**----- End of picture text -----**<br>
## RJ11 Low Profile, PC Board Layout
## RJ45 – Low Profile, Style 3 Shield
**==> picture [493 x 228] intentionally omitted <==**
**----- Start of picture text -----**<br>
25.15 .99 Max. ~ 18.80 .740<br>.076±.003 1.93±.08 .217 5.51 .350 8.89 13.08 .515*<br>Dia. .250<br>(2 PLACES) oe 6.35 .030 + .008/- .003 Dia. 1 a e —<br>.400 | wy 2 1 3 .050 1.27 .76 +.20/-.08 (6 PLACES) (5 SPACES) Aarti" 4 3.05 .120 *to top of shield a = 3.43 .135 .4.19 .165<br>10.16 4<br>7! 6 Sotom 5 _ tb | UW wv ro .217 5.51 F 10.92 .430 F<br>.075<br>.080 1.91 8<br>2.03 .120 3.05 (2 HOLES) .128±.003 3.25±.08 Dia. 75 64 16.00 .630<br>3<br>2<br>1<br>CPP TN E e<br>r et<br>For all RJ11 N and Z Series Models Part No.<br>Shown from Component Side es RJ45-8N3-B RJ45-8N3-S RJ45-8Z3<br>**----- End of picture text -----**<br>
__
258
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**6**
## **Model Dimensions** _(continued)_
## N N and Z and Z Series Series R RJ J e Ja ck ck D Dimensions imensions _(continued)_
## RJ45 Low Profile, Style 4 Shield
**==> picture [209 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
RJ45 Low Profile PC Board Layout<br>**----- End of picture text -----**<br>
**==> picture [462 x 217] intentionally omitted <==**
**----- Start of picture text -----**<br>
.700 .740<br>17.78 18.80<br>Po<br>13.08 .515* .010 .25 .076±.003 1.93±.08 Dia. .217 5.51 .250 6.35 .350 8.89<br>(2 Places) .030 +.008/-.003 Dia.<br>|ca rH —_ .76 +.20/-.08<br>.120 3.05 .135 3.43 .165 4.19 1 2 (8 Places)<br>itr Ugo .450 ef 3 4 .050 1.27 (7 Spaces)<br>*to top of shield 11.43 5<br>6<br>.217 5.51 TT 10.92 .430 H f 7 se 8 y<br>.095<br>2.41<br>.050<br>8 1.27<br>75 6 .630 .120 3.05 .128±.003 3.25±.08 Dia.<br>4 16.00 (2 Places)<br>3<br>2<br>1<br>e e) aS<br>re t’ |<br>For all RJ45 N and Z Series Models<br>Part No. Shown from Component Side<br>RJ45-8N4-B RJ45-8N4-S RJ45-8Z4<br>**----- End of picture text -----**<br>
__
259
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Engineering Notes**
260
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**7**
## **7. Technical Notes — Table of Contents**
**==> picture [367 x 136] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|I|INtrOGUCTION|ntroduction|.|2...|. . . . .|0.|. .|0c|. .|cece|. . . .|cc|. .|cece|. . . . .|cere|. . . .|ects|. . . .|eres|. . . .|ecsese|. . . . . .|scree|. . . . . .|esese|. . . . .|ss|. .|sDO2|262|
|U|Understanding|nderstanding R|RFI|FI P|Power|ower L|Line|ine F|Filters|ilters|.|........0cc0ceccccccecssecss|. . . . . . . . . . . . . . . . . . . . . . . . . . . .2|LOS|63|
|U|Understanding|nderstanding H|Hipot|ipot T|Testing|esting|.|.......ccccccccvccceccccevevvve|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|s|.|sss|2|LOG|66|
|U|Understanding|nderstanding L|Leakage|eakage C|Current|urrent (|(Touch|Touch C|Current)|urrent)|.|.......ccesceees50:20/7|. . . . . . . . . . . . . . . . . .267|
|U|Understanding|nderstanding I|Insertion|nsertion L|LOSS|oss .|.......0cccccceccccsscccsseccsses|. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|e|2|D08ss|68|
|A|Appe|ppendix A|A|n|-|-|C|Conducted|o|dix|nducted R|RFI|FI E|Emissions|missions T|Testing|esting|.|.......000cc0000eee|. . . . . . . . . . . . . . . . . . .2|209|69|
|A|Appe|ppendix B|B|n|-|-|C|Conducted|o|dix|nducted R|RFI|FI S|Susceptibility|usceptibility T|Testing|esting|.|..........0.02+.+-2/0|. . . . . . . . . . . . . . . .270|
|A|Ap|ppendix|p|C|C|-|-|H|endixHealth|ealth C|Care|are E|Equipment|quipment|.|......ccccc0ccvvceecesssssee|. . . . . . . . . . . . . . . . . . . . . . . . . . . .2|QIQ|70|
|A|Appendix|ppendix D|D|-|-|S|Safety|afety A|Agency|gency F|File|ile N|Numbers|umbers|.|........ccc0ec0eceeceesecdD/|. . . . . . . . . . . . . . . . . . . . . . . .27|I|1|
**----- End of picture text -----**<br>
261
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Introduction**
TE Connectivity (TE) has established itself as a world leader in RFI technology by introducing the first line of catalog filter products over 50 years ago. Today, TE continues to pursue the latest in RFI filter design through testing and evaluating power supplies and studying their effects.
Changing international standards obligate designers to constantly review and evaluate their filtering needs. The following section provides some basic information on RFI terminology and filter selection.
Additional information can be accessed through TE’s Corcom product internet pages at www.corcom.com
262
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Understanding RFI Power Line Filters**
## What Is Radio Frequency Interference (RFI)?
RFI is unwanted electromagnetic energy in the frequency range generally used for radio communications. The frequency ranges of interest are 10kHz to 30MHz for conducted phenomena and 30MHz to 1GHz for radiated phenomena.
## What are the modes of propagation of RFI?
RFI is propagated via radiation (electromagnetic waves in free space) and by conduction over signal lines and AC power systems.
R Radiated adiated - One of the most significant contributors to radiated RFI from electronic equipment is the AC power cord. The power cord is often an efficient antenna since its length approaches a quarter wave length for the RFI frequencies present in digital equipment and switching power supplies.
C Conducted onducted - RFI is conducted over the AC power system in two modes. Common mode (asymmetrical) RFI is present on both the line and neutral current paths with reference to the ground or earth path. Differential mode (symmetrical) RFI is present as a voltage between the line and neutral leads.
## Why Be Concerned with RFI?
The designers and manufacturers of digital equipment must concern themselves with RFI for two reasons. (1) Their equipment must operate properly in the application environment, often in the presence of significant levels of RFI. (2) Their equipment must not emit RFI that interferes with RF communications often vital to health and safety. The necessity for reliable RF communications has given rise to legal regulations ensuring RFI control for electronic equipment.
## What are the FCC requirements?
The U.S. Federal Communications Commission (FCC) has established regulations to reduce the interference potential of electronic computing devices (FCC Rules, Part 15, Subpart J). A computing device is defined as any electronic device or system that generates and uses timing signals or pulses at a rate in excess of 10,000 per second and that uses digital techniques. It is important to note that a switching power supply does not itself fall into this category, but that its emissions must still meet the limits when it is installed in a piece of equipment that is subject to the regulations.
The level of emissions the equipment must meet depends on whether it is marketed for use in a residential environment (Class B) or in a commercial, industrial, or business environment (Class A). The limits for Class B are more stringent than those for Class A (see Appendix A). Most Class B equipment must undergo certification, meaning that emissions
test data must be submitted to the FCC for type approval. Class A and all other Class B equipment must be verified—i.e. the manufacturer conducts his own emissions testing and verifies that he complies with the limits, but no forms need to be filed with the FCC.
Further details on FCC requirements can be obtained from the FCC, RF Devices Branch (Authorization and Standards Division), Washington, DC 20554, (301) 725-1585.
## What are CE markings and RFI filters?
As of January 1, 1996, electrical and electronic equipment shipped to Europe is required to be labeled with the CE marking. In order to apply the CE marking, equipment must meet the General Product Safety Directive and Electromagnetic Compatibility Directive.
RFI power line filters are components and therefore not covered by the CE requirements, but they are used in electronic systems to meet EMC specifications.
Two of the most common emission specifications are EN 55011 for industrial, science, and medical equipment, and EN 55022 for information technology equipment. The conducted emission limits for these specifications are the same and broken down to Class “A” and Class “B” limits. Electronic equipment that may be connected to a power main shared with a residential area must comply with the more stringent Class “B” limits. The measurement technique is done using quasi-peak and average detection, with different limits for each measure in dB above one microvolt.
There are several immunity tests to which electronic equipment must comply, one of which is the electrically fast transient (EFT), IEC 61000-4-4. The equipment must continue to operate during this test. The transient wave form is a 5ns rise time with a 50ns duration. A burst is induced onto the power line at 1kV with a repetition rate of 5kHz lasting 15ms and repeated every 300ms. The test simulates switching of inductive loads and contacts.
To pass the EFT test, it is important that the RFI filter’s enclosure have a good RF ground with the system’s chassis ground. This provides a lower impedance path from the safety ground to the system ground. The shielding effect of the RFI filter’s metal enclosure eliminates radiation into the system’s cabinet induced by the conducted EFT burst. Stray capacitance may occur from any of the three input power wires to chassis ground where voltage can build up from the EFT burst and cause system interrupts. The RFI filter’s inductor offers an impedance to the burst.
**7**
263
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Understanding RFI Power Line Filters** _(continued)_
In cases where the stray capacitances have caused multiple RF ground planes or where plastic enclosures are used, an inductive choke may be needed to provide isolation of the safety ground from the chassis ground.
## What Is a Power Line Interference Filter?
A power line interference filter is a primary tool available to the designer of electronic equipment to control conducted RFI both into the equipment (potential equipment malfunction) and out of the equipment (potential interference to other system elements or RF communication). By controlling the RFI conducted onto the power cord, a power line filter also contributes significantly to the amount of radiated RFI.
A power line filter is a multiple-port network of passive components arranged as a dual low-pass filter; one network for common mode attenuation, another network for differential mode attenuation. The network provides attenuation of RF energy in the stopband of the filter (typically above 10kHz), while passing the power current (50-60Hz) with little or no attenuation.
## How Does a Power Line Interference Filter Work?
Power line interference filters, as passive, bilateral networks, have complex transfer characteristics, which are extremely dependent upon source and load impedance. The magnitude of this transfer characteristic describes the attenuation performance of the filter. In the power line environment, however, the source and load impedances are not defined. Therefore the industry has standardized upon the practices of verifying filter uniformity through measurement of attenuation with 50 Ohm resistive source and load terminations. This measurement is defined to the Insertion Loss (I.L.) of the filter.
**==> picture [91 x 25] intentionally omitted <==**
where PL (Ref) is the power transferred from the source to the load without the filter, and PL is the power transferred when a filter is inserted between the source and load. The Insertion Loss may also be expressed in terms of voltage or current ratios as shown:
**==> picture [91 x 25] intentionally omitted <==**
**==> picture [87 x 25] intentionally omitted <==**
where VL (Ref) and IL are measured without a filter and VL and IL are measured with a filter.
It is important to note that Insertion Loss does not describe the RFI attenuation provided by a filter in the power line environment. In the power line environment the relative magnitudes of the source and load impedances must be estimated and the appropriate filter configuration selected such that the greatest possible impedance mismatch occurs at each termination.
This dependence of filter performance on terminated impedances is the basis for the concept of “mismatching networks.”
## What is the concept of power line filters as “Impedance Mismatching Networks”?
RFI power line filters can be thought of as “impedance mismatching networks” at higher frequencies in the attenuation band. Network analysis shows that the greater the mismatch of filter impedance to terminating impedance, the more effective the filter is in attenuating RF energies.
Common mode power line impedance is considered to be low (on the order of 50 Ohms). Thus, following the concept of an impedance mismatch, Corcom power line filters employ a high common mode impedance (series inductance) on the power line side of the filter.
For load (equipment) side common mode impedance mismatch, Corcom products are available with a high impedance (series inductance) or a low impedance (shunt capacitance).
High (common mode) impedance filters for use with low impedance equipment include the EP, H, 6A Q, R and V series. Low (common mode) impedance filters for use with high impedance equipment include the B, EC, ED, EF, G, K, N, 3A Q, S, SK, T, W, X, Y, and Z series.
Knowing the input impedance of your equipment, then, may be useful in initially selecting the filter series most likely to solve your RFI problems. However, since this impedance is almost certainly complex (having both resistive and reactive components), it may vary widely over the RFI frequency range. Hence a variety of series should be evaluated in your quest for the most effective filter in any one application.
## Do all filter networks with the same circuit and element values perform identically?
All filter networks with the same circuit and element values do not perform identically. Element values are specified and measured at a single frequency (usually 1kHz). Filter performance is required over the entire frequency spectrum, not just at the frequency of component measurement. The type of component construction and method of incorporation into a filter are extremely important to filter performance.
264
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Understanding RFI Power Line Filters** _(continued)_
Figure 1 illustrates the high-frequency performance difference between the three leaded capacitor construction employed by TE and a conventional method of construction. Both units would be specified by the same nominal 1kHz component value, approximately 5000pF.
## Figure 1: Insertion Loss
**==> picture [208 x 161] intentionally omitted <==**
**----- Start of picture text -----**<br>
db V Conventional<br>0 Construction<br>10<br>20<br>30<br>40 TE Connectivity<br>Construction<br>50<br>60<br>70<br>80<br>90<br>100<br>20.0 40.0 60.0<br>Frequency MHz<br>**----- End of picture text -----**<br>
## How Do You Select a Power Line Interference Filter?
The only way to select and qualify a power line interference filter is to test the unit in your equipment. As mentioned above, the performance is highly dependent on equipment load impedance. Filter performance cannot be derived from single impedance (50 Ohm) insertion loss data. Performance is a complex function of filter element impedances and equipment impedances which vary in magnitude and phase over the frequency spectrum of interest. Filter selection testing should be performed in your equipment to your required level of performance for both conducted emission control (FCC, VDE) and susceptibility control.
## How do you perform conducted emission tests?
Conducted emission testing requires a quiet RF environment—usually a shielded enclosure—a line impedance stabilization network, and an RF voltage instrument such as a tuned receiver or a spectrum analyzer. Additional testing information is given in Appendix A. The RF ambient of the test environment should be at least 20 dB below the desired compliance limit for accurate results. The line impedance stabilization network (LISN) is required to establish a desired source impedance for the power line input. This is an important part of the test procedure, since this impedance directly affects the measured emission levels. The correct bandwidth for the
## How do you perform susceptibility testing?
Susceptibility testing involves injection of noise onto the power input lines while monitoring the equipment for proper operation. Quantification of the noise levels to be found in the equipment environment is difficult at best. Through analysis of solutions to specific susceptibility problems, TE has developed recommended noise injection levels, which proved a high level of confidence for reliable equipment operation in the real world environment. The test methods and injection noise levels are found in Appendix B.
## Is installation important to filter performance?
Mounting and wiring of the filter are critical influences on its performances. A power line filter is best installed at the power line input point of your equipment. The filter is a barrier to high frequency signals. Its purpose must not be defeated by stray capacitance coupling the power input leads to the power output leads, or to any other conductors in the protected equipment.
Normally the case of the filter is bolted to the framework or chassis of the electronic equipment it protects. The line side leads should be kept short and well separated from the load side leads. The ideal isolation system is a bulkhead-mounted filter incorporating a line cord connector, such as the Corcom EC, ED, or EF power line filter series.
## How Do You Know Which Filter To Test?
A filter, or ordered group of filters, likely to solve your interference control problem can be obtained by using the selector chart at the front of each section. Every Corcom filter series is available in a range of current ratings and packages. Detailed specifications, including prices, are listed on the individual series’ catalog sheets referenced in the selector chart. Telephone numbers of distributors who stock all TE products are listed on the back cover of this catalog.
## Why Be Concerned with Safety Agency Requirements?
All components in the AC power system, including power line filters, must be safe from potential fire and shock hazard. The standards set by the various safety agencies, like UL, CSA, VDE, and SEV, provide guidelines to assist the designer in specifying safe and reliable components. Components which carry the compliance symbols from these agencies have been designed and manufactured to comply with these standards. A summary of safety agency requirements can be found in Appendix C.
**7**
measurement receiver is also a critical test parameter.
265
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Understanding RFI Power Line Filters** _(continued)_
## What are the significant requirements of UL and CSA?
UL and CSA are primarily concerned with high potential withstand capability, temperature rise, creepage distances, and material temperature capability at the time of manufacture.
## What are the additional aspects of VDE safety requirements?
In addition to the requirements of UL and CSA, VDE specifies limits of hipot, insulation resistance, and change of component values, at the conclusion of extreme environmental conditioning. The conditioning includes life tests at elevated temperatures, long term humidity, and temperature/humidity cycling. Components that bear the VDE symbol of safety have been designed and tested not only for initial safety but also for safety over the life of the product.
## How Do You Specify a Power Line Filter?
The filter you have selected through system testing can best be specified by the data parameters found on the appropriate catalog page. Combining the product family parameters listed under the “specifi-
cations” with the package style and dimensional data from your specific filter will adequately define your selection.
## Are there other parameters that need to be specified?
There are three additional requirements that are often specified. Below are our recommended values:
1. Insulation Resistance: 6000 M @ 100VDC
2. Current Overload: 6 X rated current for 8 seconds
3. Humidity: 21 days at 40°C 95% RH
## What are the test methods for verification of the important specification parameters?
Some filter specifications may be unfamiliar to you or may require slightly different measuring techniques than you have been using for other components. It is very important that supplier and customer use the same techniques for verification of electrical specifications, in order to assure an uninterrupted flow of quality components. Three specifications that must be clearly understood are hipot testing, leakage current, and insertion loss.
## **Understanding Hipot Testing**
The term “hipot” is an acronym for “high potential.” Hipot testing stresses the insulation and capacitors of a filter assembly by applying a voltage much higher than is usually experienced in normal operation. The purpose of hipot specifications is to assure safety and reliability.
All the major safety agencies require hipot testing for qualification of power line filters, and also require that each production unit undergo hipot testing to verify the integrity of the line-to-ground components and insulation. Every Corcom filter is hipot tested twice: once during assembly and again after completion. Applying hipot testing as an incoming inspection procedure requires a thorough understanding of its uses and limitations.
Hipot test voltages are applied from each line (both lines tied together for VDE) to ground and from lineto-line. The line-to-ground voltages are always higher. Test voltages may be specified as AC or DC, with the DC voltages at least 1.414 times the AC voltages.
For incoming inspection testing, TE recommends using the voltages given as “hipot rating” for each filter in the catalog. These DC voltages will always be equal to or higher than the peak AC voltage carried by any safety agency whose approval the filter carries. A DC hipot test is generally used.
A variety of hipot testers is available from a number of manufacturers. The tester chosen should have at
## least a 500VA rating.
The following precautions must be observed to insure the safety of the operator and the validity of the test:
1. THESE VOLTAGES CAN BE LETHAL—use the utmost safety precautions to protect the test operator.
2. The possibility of high surge currents and oscillatory overvoltage during sudden application of the test voltage requires some method of limiting the applied current or increasing the voltage comparatively slowly.
3. For AC hipot tests, use an oscillograph to monitor the applied voltage. The current limiting circuit may react with the filter circuit to distort the 60Hz waveform. This may produce a peak voltage that exceeds the expected peak value of a sinusoidal voltage having the specified rms value. The peak voltage should be 1.414 times the rms value. Higher voltages may cause unwarranted failures due to the peak currents exceeding the trip setting.
4. For line-to-line hipot testing, remember that most filters have a bleeder resistor (typical value 100k to 10M) to discharge the line-to-line capacitors. Be sure to set the trip point of the hipot tester above the current level that will flow through the bleeder resistor: 10mA is usually a safe value.
266
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Understanding Leakage Current (Touch Current)**
Leakage current (also referred to as “touch current”) is an important specification of power line filters. There has always been an undeserved negative connotation to this term. Leakage current is not a function of the quality of components, but is a direct function of the line-to-ground capacitance value. The larger the capacitance, the lower the impedance to common mode currents, and the greater the common mode interference rejection. Hence, leakage current is a measure of filter performance—the higher, the better.
Why, then, do safety agencies specify a maximum allowable leakage current? This is done in order to limit the magnitude of expected ground return currents. The line-to ground capacitors provide a path for 50/60Hz current to flow to the chassis. As long as the equipment is grounded, these currents will flow in the ground circuit and present no hazard. However, in the unlikely but always possible circumstance where the ground circuit is faulty, the earth connection may be established by the body of a person. If this should occur, the maximum leakage current specification limits the ground return current to a safe value, typically 0.5 to 5.0mA. The limits set by safety agencies are based on end user equipment specifications, such as those given below.
## Capacitive Current Limits
|Capacitive Current Limits|Capacitive Current Limits||
|---|---|---|
|L<br>C<br>o<br>u<br>n<br>t<br>r<br>y<br>~~Country~~|L<br>S<br>p<br>e<br>c<br>i<br>f<br>c<br>a<br>t<br>i<br>o<br>n<br> <br>~~Specification~~|L<br>i<br>m<br>i<br>t<br>s<br>f<br>o<br>r<br>C<br>l<br>a<br>s<br>s<br>I<br> G<br>r<br>o<br>u<br>n<br>d<br>e<br>d<br>E<br>q<br>u<br>i<br>p<br>m<br>e<br>n<br>t<br>Limits for Class<br>|<br>~~Grounded Equipment~~|
|U.S.A.|UL 60950 3.5 mA, 120V, 60Hz|UL 60950 3.5 mA, 120V, 60Hz|
|Canada|C22.2 No. 60950 3.5 mA, 120V, 60Hz||
|Europe|EN 60950 3.5 mA, 250V, 50Hz|EN 60950 3.5 mA, 250V, 50Hz|
Since the largest component of leakage current is usually from the power line filter, it is prudent to set a maximum leakage current limit for the filter itself. There has been a tendency in the industry to specify the minimum leakage current to comply with all agency requirements, usually 0.5mA. This specification decision should not be made arbitrarily, because often the size and cost of the filter can be reduced by allowing a greater maximum leakage current.
## Figure 2: Leakage Current Measurement
**==> picture [240 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
Filter<br>Variac Isolation Under Test<br>Transformer<br>60HzAC No Connection<br>Input To Load<br>Voltage Terminals<br>V<br>O yl O<br>120V, 60Hz<br>or 1500<br>250V, 60Hz<br>H N<br>0.15<br>**----- End of picture text -----**<br>
## _Note that filter case must be floating, not grounded._
The circuit of Figure 2 illustrates the measurement technique for leakage current. The leakage limits apply to each side of the line independently. The test circuit provides the correct value by shunting the line-to-ground path that is not being measured by the millimeter impedance. This test is realistic, because power to a system is provided by a hot line and a neutral line, with the neutral basically at ground potential, thus providing no addition to the leakage.
Note that the leakage current is directly proportional to line voltage and frequency. Hence, it is unwise to specify an operation frequency greater than 60Hz (e.g., 400Hz) when leakage current limits must also be met.
**7**
267
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Understanding Insertion Loss**
## What is insertion loss?
Insertion loss is the ratio (expressed in dB) of the signal voltage transferred from source to load without a filter, to the signal voltage transferred from source to load when the filter is inserted. As discussed above (“How Does a Power Line Interference Filter Work?”), insertion loss is not a measure of filter performance in the power line equipment environment.
## How is it measured?
If the terminating impedances are standardized, then it becomes meaningful to measure insertion loss, but the results so obtained can be applied only to an identical circuit. The most popular set-up is to make the source and load impedances each 50 Ohms, resistive.
The most important aspect of insertion loss measurement is consistency. It is particularly critical that supplier and user employ the same measurement techniques. The standard method of insertion loss measurement used by TE is as follows:
Insertion loss is easily measured with a spectrum analyzer or tuned receiver and a tracking generator. A zero dB reference is established without the filter. Then the filter is inserted, and the attenuation provided over the desired frequency range is recorded.
For a power line filter we are interested in signal attenuation in two different modes:
> C Common ommon M Mode ode ( (CM) CM) — signals present on both sides of the line (hot and neutral) referenced to ground.
D Differential ifferential M Mode ode ( (DM) DM) — signals present on one side of the line, referenced to the other.
Accordingly, we may deal with CM insertion loss or DM insertion loss or both.
For the common mode, the line and neutral terminals are at the same potential (same magnitude and phase) and may be considered as being in parallel. CM current circulates between this pair and the common (ground) lead. CM insertion loss is measured by strapping the line and neutral terminals together on both sides of the filter (Figure 3). All CM insertion loss data published in the Corcom product catalog are measured this way.For differential mode, the signals on the line and neutral terminals are of the same magnitude but opposite phase. Current circulates between the line and neutral leads only. DM insertion loss is tested with 50 Ohm 180° power splitters as shown in Figure 4. All DM insertion loss data published in the Corcom product catalog are measured this way.
Figure 3: CM Insertion Loss Measurement
**==> picture [190 x 151] intentionally omitted <==**
**----- Start of picture text -----**<br>
50 Om L L<br>N N<br>Tracking 50<br>Generator Spectrum<br>Analyzer<br>G G<br>L497 :<br>Test Connection<br>50 Om<br>Tracking 50<br>Generator Spectrum<br>Analyzer<br>, 4 :<br>**----- End of picture text -----**<br>
## _Reference Connection_
For differential mode, the signals on the line and neutral terminals are of the same magnitude but opposite phase. Current circulates between the line and neutral leads only. DM insertion loss is tested with 50 Ohm 180° power splitters as shown in Figure 4. All DM insertion loss data published in the Corcom product guide are measured this way.
Figure 4: DM Insertion Loss Measurement
**==> picture [189 x 167] intentionally omitted <==**
**----- Start of picture text -----**<br>
50 Splitter Om<br>50 Tay L L<br>180o FILTER 180o<br>L G N 50 a<br>Tracking Spectrum<br>Generator Analyzer<br>Test Connection<br>50 Splitter Om<br>I<br>50 ray ——— DM<br>180o 180o<br>I 50<br>Tracking DM Spectrum<br>ST Generator Analyzer<br>Reference Connection<br>**----- End of picture text -----**<br>
_Note that all signal leads in Figures 3 and 4 are 50 Ohm coaxial cables._
1. Make your 0dB reference measurement over the entire frequency range, not just at one or two points.
2. Make sure the filter case has a good RF ground connection.
3. Make sure the wiring to the load side of the filter is well separated from the wiring to the line side, to avoid RF coupling around the filter.
268
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**7**
## **Understanding Insertion Loss** _(continued)_
## What can it be used for?
Standardized insertion loss data will not accurately predict a filter’s performance in your equipment. However, it does serve as an important tool for verifying product consistency through incoming inspection.
The criterion for acceptance would be that the measured insertion loss must either meet or exceed the
published data when tested in the standardized manner.
Accordingly, “typical” insertion loss data is not meaningful. The data to which you test should be minimum values. Most of the insertion loss data published by TE are guaranteed minimums, and as such can be tested for a positive indication of component consistency.
## **Appendix A - Conducted RFI Emissions Testing**
## Conducted RFI Emissions Testing
Since conducted emissions testing is usually done to insure that your equipment will comply with the limits of FCC Part 15 or EN55022, the test methods used should conform to the specifications of these two agencies. You will need the following equipment:
1. Shielded room, to allow measurement with minimal background interference.
2. Two 50 Ohm line impedance stabilization networks (LISNs), fixing the line-side impedances as mandated by FCC and CISPR.
3. Spectrum analyzer or tuned receiver, with CISPR quasipeak detector, covering the range from 10kHz to 30MHz.
## Figure A2
**==> picture [146 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
FCC Part 15 and EN55022<br>**----- End of picture text -----**<br>
**==> picture [188 x 97] intentionally omitted <==**
**----- Start of picture text -----**<br>
80<br>QUASI-PEAK CLASS A<br>S<br>60 —= AVERAGE CLASS A<br>QUASI-PEAK CLASS B<br>Le<br>40 AVERAGE CLASS B ;<br>-----J------b---<br>.1 .15 .5 1 5 10 30<br>Frequency in MHz<br>**----- End of picture text -----**<br>
## Figure A1
**==> picture [241 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
ra| 250 U H 50 U H |<br>To | 1.2 UF 8 UF .25 | uF 0<br>Power | 10 fa 5 a 1000 la 50 m.<br>Source ||<br>|4<br>]<br>| 10 a 5 a 1000 me °<br>|<br>1.2 U - 8 +— .25 J 0<br>| UF | UF coH<br>eo 250 PLL H 50 PLL H |<br>50 Equipment<br>Line Impedence Spectrum<br>Stabalization Network Analyzer<br>**----- End of picture text -----**<br>
The limits for FCC Part 15 and EN55022 are shown in Figure A2. To which one or more of these limits you will test is determined by whether your equipment is marketed in the United States (FCC) or Europe (EN55022) and into which class of operation it falls at each agency.
269
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Appendix B - Conducted RFI Susceptibility Testing**
## Conducted RFI Susceptibility Testing
You can determine whether or not your equipment is susceptible to conducted RFI by subjecting it to predetermined levels of CM and DM interferences, and noting any malfunctions that occur. Such a test approximates real-world interference by standardized test conditions, according to previous experience. TE’s recommendation for conducted susceptibility testing follows. The equipment required will be:
1. Shielded room, to eliminate spurious signals.
2. Two 50 Ohm line impedance stabilization networks (LISNs).
3. 50 Ohm signal generator, 1 Watt output.
4. 50 Ohm (or less) pulse generator, 0 to 300 Volts output.
CW signals should be injected common-mode, using peak levels of:
- 7 Volts from 10kHz to 150kHz
- 2 Volts from 150kHz to 500kHz
- 1 Volt from 500kHz to 30MHz
Pulse waveforms should be injected common mode and differential mode, pulse width 10 microseconds, rise time 1 microsecond, repetition rate 60Hz and varied in phase 0 to 360 degrees on the 60Hz power waveform. CM pulses should have peak levels of 2 volts; DM pulses should have peak levels of twice the rated line voltage.
These levels are based on emission data gathered at TE and are considered typical of the levels encountered close to high noise sources.
**==> picture [81 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
A. Common Mode<br>**----- End of picture text -----**<br>
**==> picture [277 x 309] intentionally omitted <==**
**----- Start of picture text -----**<br>
L poe! 50 H<br>|<br>| 5 lay |<br>To<br>| [|]<br>Power | 8 Uv F 1000 }O 1 vy F<br>Source |<br>| | 50 fa<br>| 8 v F 1000 la 1 v F<br>| [l]<br>| 5 ray |<br>N ei 50 t___'!| F<br>Equipment<br>Line Impedence<br>Stabalization Network<br>B. Differential Mode<br>L ee 50 H ee<br>|<br>| 5 lay | 1 u F<br>To<br>| [|]<br>Power 8 u F | 50 a<br>|<br>Source |<br>| [|]<br>| 8 u F<br>| [|]<br>| 5 fey | 1 u F<br>N He 50 t___! F<br>Equipment<br>Line Impedence<br>Stabalization Network<br>**----- End of picture text -----**<br>
## Figure A3
## **Appendix C - Health Care Equipment**
## UL 60601-1 Medical Electrical Equipment
The major safety standard for electro-medical devices is the IEC 60601 series, with the IEC 60601-1 standard covering all generic requirements. This standard is the basis of the various harmonized equivalents, the European equivalent is EN 60601, the UL equivalent is UL60601-1 and the CSA equivalent is C22.2 No. 60601-1
Underwriters Laboratories’ medical electrical equipment specification is broken down into two basic categories.
- A A. . P Patient atient C Care are E Equipment: quipment: “Equipment that is intended to be used on or with, or likely to be contacted by, a patient in a health care facility in the course of his treatment.” This equipment can have a maximum leakage current of 100 A at 120VAC, 60Hz.
- B B. . N Non on ~~-p -~~ p atient atient E Equipment: quipment: “Equipment primarily for use in a health care facility that is intended for use where contact with a patient is unlikely.” This equipment can have a maximum leakage current of 300 A at 120VAC, 60Hz.
All filters starting with “H” and “M” are for medical equipment applications. They can be used in both patient care equipment and non-patient equipment. All other Corcom products with an “E” in the part number are suitable for use only in (120V) non-patient equipment.
270
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
**7**
## **Appendix D - Safety Agency File Numbers**
## Filters
## UL Recognition
Guide FOKY2, File E48570 _All except IK series_
Guide ECBT2, File E106884 _Non-filtered DB Series connectors only_
## Component Recognized by UL to Canadian Requirements
## Power Entry Modules
## UL Recognition
Guide FOKY2, File E48570 _All filtered power entry modules_
Guide AXUT2, File E61290
_All non-filtered fuseless modules and 15SRB with suffix 1, 2, 8, P, S1 or S8_
Guide AYVZ2, File E59193
_All non-filtered fused modules_
Guide ECBT8, File E106884
_Non-filtered DB Series connectors only_
## Component Recognized by UL to Canadian Requirements
UL Guide FOKY2, File E48570 CSA Guide FOKY8, File E48570
_AFC, FFA, FFD and DFC Series only_
## UL Listing
Guide FNFT, File E117533 _Model 3FL3 ballast filter_
## CSA Certification
Class 2221, File LR46870 _All except IK series_
VDE Approval
File 706400-4730 _All except IK series_
TUV Approval File E2173035 _DAF, DAS Series_ File E2173028.01 _DCB, DCF Series_ File T72091763.01 _Filtered DB Series_ File T72081913.01 _Non-filtered DB Series (Connectors)_
## Signal Sentry Modular Jacks
UL Recognition Guide DUXR2, File E136872 wl
## CSA Certification
## Component Recognized by UL to Canadian Requirements
Guide AXUT8, File E61290 _Models: 15CE1, 15CS1, 15CBE1, 15CBS1 and 15CU Series_
## CSA Certification
Class 2221, File LR46870 _Filtered modules_
Class 6221, File LR68190 _Non-filtered modules_
## TUV Approval
File T72051210.01
_Non-filtered DC rated P Series with VDE rating only_
## VDE Approval
File 706400-4730 _All filtered modules except J Series_
File 706400-1550 _All non-filtered modules except J Series_
## Accessories
UL Recognition
Guide ECBT2, File E106884
_MA100_
Guide XUHT2 File E106794 _TS Series_
## CSA Certification
Class 6233, File LR88865 _MA100_
Class 4872, File LR96220
271
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Engineering Notes**
272
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Part Number Index and Cross Reference**
|Catalog|TE|Page|Catalog|TE|Page|
|---|---|---|---|---|---|
|Number|Ordering Number|Number|Number|Ordering Number|Number|
|1CFE1|6609113-1|130|1EGG8C-2|6609115-9|166|
|1CFS1|6609113-2|130|1EGS1-1|6609117-1|166|
|1CHE1|6609114-1|130|1EGS1-2|6609117-2|166|
|1CHS1|6609114-2|130|1EHG1-2|6609116-1|166|
|1CUFE1|2-1609113-2|134|1EHG8-2|1-1609117-4|166|
|1CUFF1|2-1609114-2|134|1EHGS1-2|1609988-1|166|
|1CUFS1|2-1609113-7|134|1EJH1|6609008-1|154|
|1EAH1|6609002-1|149|1EJH2|6609008-6|154|
|1EAS1|6609005-6|149|1EJH8|2-6609008-8|154|
|1EB1|6609020-1|15|1EJHP|6609008-7|154|
|1EB3|6609020-2|15|1EJHS1|1-6609008-6|154|
|1EBF1|6609018-1|138|1EJHS8|2-6609008-2|154|
|1EBF4|6609018-2|138|1EJM1|6609985-1|154|
|1EBH1|6609003-1|149|1EJM8|1-6609985-3|154|
|1EBP|6609063-1|21|1EJMS1|6609985-7|154|
|1EBS1|1-6609005-1|149|1EJMS8|1-6609985-8|154|
|1EC1|6609017-1|141|1EJS1|6609006-4|154|
|1EC2|6609017-2|141|1EJS8|3-6609006-7|154|
|1EC4|6609017-3|141|1EJT1|2-6609006-1|163|
|1EC8|6609017-4|141|1EJT8|2-6609006-6|163|
|1ED1|6609016-1|144|1EK1|6609027-1|49|
|1ED2|6609016-2|144|1EK3|6609027-2|49|
|1ED4|6609016-3|144|1EOP|6609064-1|21|
|1ED8|6609016-4|144|1ER1|6609031-1|61|
|1EDK1|6609033-1|18|1ER3|6609031-2|61|
|1EDK3|6609033-2|18|1EZP|6609062-1|92|
|1EDP|6609065-1|21|1IK1C|1-6609085-1|46|
|1EEA1|6609000-1|149|1VB1|6609021-1|15|
|1EEA2|6609000-2|149|1VB3|6609021-2|15|
|1EEAP|6609000-3|149|1VDK1|6609034-1|18|
|1EEB1|6609001-1|149|1VDK3|6609034-2|18|
|1EEB2|6609001-2|149|1VK1|6609028-1|49|
|1EEBP|6609001-3|149|1VK3|6609028-2|49|
|1EEJ1|6609006-1|154|1VR1|6609032-1|61|
|1EEJ2|6609006-2|154|1VR3|6609032-2|61|
|1EEJ8|3-6609006-2|154|2EB1|6609020-3|15|
|1EEJP|6609006-3|154|2EB3|6609020-4|15|
|1EF1F|6609015-1|160|2EDL1S|6609122-1|176|
|1EF2F|6609015-2|160|2EDL1SC|6609122-2|176|
|1EF4|6609014-3|160|2EDL1SCM|6609122-3|176|
|1EF8|6609014-4|160|2EDL1SM|6609122-4|176|
|1EGG1-1|6609115-1|166|2EDL4|6609122-5|176|
|1EGG1-2|6609115-3|166|2EDL4C|6609122-7|176|
|1EGG1C-1|6609115-4|166|2EDL4CM|6609122-9|176|
|1EGG1C-2|6609115-5|166|2EDL4M|1-6609122-0|176|
|1EGG8-1|6609115-6|166|2EK1|6609027-3|49|
|1EGG8-2|6609115-7|166|2EK3|6609027-4|49|
|1EGG8C-1|6609115-8|166|2ER1|1609031-3|61|
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
273
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Part Number Index and Cross Reference**
|Catalog|TE|Page|Catalog|TE|Page|
|---|---|---|---|---|---|
|Number|OrderingNumber|Number|Number|OrderingNumber|Number|
|2ER3|6609031-4|61|3EEJ2|6609006-6|154|
|2EYP|6609061-2|92|3EEJ8|3-6609006-3|154|
|2EZP|6609062-2|92|3EEJP|6609006-7|154|
|2RJ11-6L-B|3-6609208-6|248|3EF1F|6609015-3|160|
|2VB1|6609021-3|15|3EF2F|6609015-4|160|
|2VB3|6609021-4|15|3EF4|6609014-7|160|
|2VK1|6609028-3|49|3EF8|6609014-8|160|
|2VK3|6609028-4|49|3EGG1-1|1-6609115-1|166|
|2VR1|6609032-3|61|3EGG1-2|1-6609115-2|166|
|2VR3|6609032-4|61|3EGG1C-1|1-6609115-3|166|
|3AYO1|6609066-1|111|3EGG1C-2|1-6609115-5|166|
|3CFE1|6609113-5|130|3EGG8-1|1-6609115-7|166|
|3CFS1|6609113-6|130|3EGG8-2|1-6609115-8|166|
|3CHE1|6609114-5|130|3EGG8C-1|1-6609115-9|166|
|3CHS1|6609114-6|130|3EGG8C-2|2-6609115-0|166|
|3CUFE1|2-1609113-3|134|3EGS1-1|6609117-3|166|
|3CUFF1|2-1609114-3|134|3EGS1-2|6609117-4|166|
|3CUFS1|2-1609113-8|134|3EH1|6609012-1|169|
|3DAF1|6609075-4|212|3EH3|6609012-2|169|
|3DAFP|6609075-3|212|3EHG1-2|6609116-2|166|
|3DAS1|1-6609075-7|212|3EHG8-2|1-1609117-5|166|
|3EAH1|6609002-2|149|3EHGS1-2|1609988-2|166|
|3EAS1|6609005-7|149|3EHQ1|6609054-1|37|
|3EB1|6609020-5|15|3EHQ3|6609054-2|37|
|3EB3|6609020-6|15|3EHQ8|6609054-3|37|
|3EBF1|6609018-3|138|3EHQ8M|6609054-4|37|
|3EBF4|6609018-4|138|3EHQ8M|6609054-4|37|
|3EBH1|6609003-2|149|3EHT1|6609053-1|40|
|3EBP|6609063-2|21|3EHT3|6609053-2|40|
|3EBS1|1-6609005-2|149|3EHT7|6609053-3|40|
|3EC1|6609017-5|141|3EHT7M|6609053-4|40|
|3EC2|6609017-6|141|3EHZ1|6609055-1|43|
|3EC4|6609017-7|141|3EJH1|6609008-2|154|
|3EC8|6609017-8|141|3EJH2|6609008-8|154|
|3ED1|6609016-5|144|3EJH8|2-6609008-9|154|
|3ED2|6609016-6|144|3EJHP|6609008-9|154|
|3ED4|6609016-7|144|3EJHS1|1-6609008-7|154|
|3ED8|6609016-8|144|3EJHS8|2-6609008-3|154|
|3EDK1|6609033-3|18|3EJM1|6609985-2|154|
|3EDK3|6609033-4|18|3EJM8|1-6609985-4|154|
|3EDP|6609065-2|21|3EJMS1|6609985-8|154|
|3EEA1|6609000-4|149|3EJMS8|1-6609985-9|154|
|3EEA2|6609000-5|149|3EJS1|6609006-8|154|
|3EEAP|6609000-6|149|3EJS8|3-6609006-8|154|
|3EEB1|6609001-4|149|3EJT1|2-6609006-2|163|
|3EEB2|6609001-5|149|3EJT8|2-6609006-7|163|
|3EEBP|6609001-6|149|3EK1|6609027-5|49|
|3EEJ1|6609006-5|154|3EK3|6609027-6|49|
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
274
For email, phone or live chat, please go to
**te.com/help**
**corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Part Number Index and Cross Reference**
|Catalog|TE|Page|Catalog|TE|Page|
|---|---|---|---|---|---|
|Number|Ordering Number|Number|Number|Ordering Number|Number|
|3EK7|6609027-7|49|3VK3|6609028-6|49|
|3EK7M|6609027-8|49|3VK7|6609028-7|49|
|3EMC1|1-6609037-1|24|3VK7M|6609028-8|49|
|3EMC3|1-6609037-8|24|3VQ1|6609049-1|58|
|3EOP|6609064-2|21|3VQ3|6609049-2|58|
|3EP1|6609037-1|27|3VQ8|6609049-3|58|
|3EP3|6609037-2|27|3VQ8M|6609049-4|58|
|3EP7|6609037-3|27|3VR1|6609032-5|61|
|3EP7M|6609037-4|27|3VR3|6609032-6|61|
|3EQ1|6609048-1|58|3VR7|6609032-7|61|
|3EQ3|6609048-2|58|3VR7M|6609032-8|61|
|3EQ8|6609048-3|58|3VS1|6609042-1|68|
|3EQ8M|6609048-4|58|3VSK1|6609036-1|75|
|3ER1|6609031-5|61|3VSK3|6609036-2|75|
|3ER3|6609031-6|61|3VSK7|6609036-3|75|
|3ER7|6609031-7|61|3VSK7M|6609036-4|75|
|3ER7M|6609031-8|61|3VV1|6609043-1|86|
|3ERK1|1-1609036-7|65|3VW1|6609044-1|86|
|3ESK1|6609035-1|75|3VW1|6609044-1|86|
|3ESK3|6609035-2|75|4EDL1S|1-6609122-1|176|
|3ESK7|6609035-3|75|4EDL1SC|1-6609122-2|176|
|3ESK7M|6609035-4|75|4EDL1SCM|1-6609122-3|176|
|3ET1|6609046-1|80|4EDL1SM|1-6609122-4|176|
|3ET3|6609046-2|80|4EDL4|1-6609122-5|176|
|3ET7|6609046-3|80|4EDL4C|1-6609122-6|176|
|3EX1|6609059-1|92|4EDL4CM|1-6609122-7|176|
|3EXLA2S|6609119-1|180|4EDL4M|1-6609122-8|176|
|3EXM1S|6609131-7|184|4EXP|6609060-4|92|
|3EXM4|6609131-8|184|4EYP|6609061-4|92|
|3EXM4S|6609131-9|184|4RJ11-6L-B|6609213-1|248|
|3EXP|6609060-3|92|5EB1|6609020-7|15|
|3EYP|6609061-3|92|5EB3|6609020-8|15|
|3EZ1|6609059-2|92|5EFLA2S|6609118-1|180|
|3EZLA2S|6609120-1|180|5EFM1|2-6609129-1|184|
|3EZM1S|6609132-8|184|5EFM1C|2-6609129-2|184|
|3EZM4|6609132-9|184|5EFM1S|2-6609129-3|184|
|3EZM4S|1-6609132-0|184|5EFM1SC|2-6609129-5|184|
|3EZP|6609062-3|92|5EFM4|2-6609129-6|184|
|3FL3|2-6609092-3|33|5EFM4C|2-6609129-7|184|
|3MV1|6609056-1|54|5EFM4S|2-6609129-8|184|
|3VAQ3|6609057-1|12|5EFM4SC|3-6609129-0|184|
|3VAQ8F|6609058-1|12|5EHM1|1-6609130-1|184|
|3VAQ8FS|6609058-2|12|5EHM1S|1-6609130-3|184|
|3VB1|6609021-5|15|5EHM4|1-6609130-4|184|
|3VB3|6609021-6|15|5EHM4S|1-6609130-5|184|
|3VDK1|6609034-3|18|5EK1|6609027-9|49|
|3VDK3|6609034-4|18|5EK3|1-6609027-0|49|
|3VK1|6609028-5|49|5EK7|1-6609027-1|49|
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
275
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Part Number Index and Cross Reference**
|Catalog|TE|Page|Catalog|TE|Page|
|---|---|---|---|---|---|
|Number|OrderingNumber|Number|Number|OrderingNumber|Number|
|5EK7M|1-6609027-2|49|6EDL1SM|2-6609122-2|176|
|5ER1|6609031-9|61|6EDL4|2-6609122-3|176|
|5ER3|1-6609031-0|61|6EDL4C|2-6609122-4|176|
|5ER7|1-6609031-1|61|6EDL4CM|2-6609122-5|176|
|5ER7M|1-6609031-2|61|6EDL4M|2-6609122-6|176|
|5VB1|6609021-7|15|6EDP|6609065-3|21|
|5VB3|6609021-8|15|6EEA1|6609000-7|149|
|5VK1|6609028-9|49|6EEA2|6609000-8|149|
|5VK3|1-6609028-0|49|6EEAP|6609000-9|149|
|5VK7|1-6609028-1|49|6EEB1|6609001-7|149|
|5VK7M|1-6609028-2|49|6EEB2|6609001-8|149|
|5VR1|6609032-9|61|6EEBP|6609001-9|149|
|5VR3|1-6609032-0|61|6EEJ1|6609006-9|154|
|5VR7|1-6609032-1|61|6EEJ2|1-6609006-0|154|
|5VR7M|1-6609032-2|61|6EEJ8|3-6609006-4|154|
|6AYO1|6609066-2|111|6EEJP|1-6609006-1|154|
|6CFE1|6609113-9|130|6EF1F|6609015-5|160|
|6CFS1|1-6609113-0|130|6EF2F|6609015-6|160|
|6CHE1|6609114-9|130|6EF4|1-6609014-1|160|
|6CHS1|1-6609114-0|130|6EF8|1-6609014-2|160|
|6CUFE1|2-1609113-4|134|6EG1|6609050-1|35|
|6CUFF1|2-1609114-4|134|6EGG1-1|2-6609115-2|166|
|6CUFS1|2-1609113-9|134|6EGG1-2|2-6609115-3|166|
|6DAF1|6609075-6|212|6EGG1C-1|2-6609115-4|166|
|6DAFP|6609075-5|212|6EGG1C-2|2-6609115-6|166|
|6DAS1|2-6609075-1|212|6EGG8-1|2-6609115-8|166|
|6EAH1|6609002-3|149|6EGG8-2|2-6609115-9|166|
|6EAS1|6609005-8|149|6EGG8C-1|3-6609115-0|166|
|6EBF1|6609018-5|138|6EGG8C-2|3-6609115-1|166|
|6EBF4|6609018-6|138|6EGS1-1|6609117-5|166|
|6EBH1|6609003-3|149|6EGS1-2|6609117-6|166|
|6EBS1|1-6609005-3|149|6EH1|6609012-3|169|
|6EC1|6609017-9|141|6EH3|6609012-4|169|
|6EC2|1-6609017-0|141|6EH4|6609013-1|169|
|6EC4|1-6609017-1|141|6EH5|6609013-4|169|
|6EC8|1-6609017-2|141|6EH8|6609013-3|169|
|6ED1|6609016-9|144|6EH9|6609013-2|169|
|6ED1C|1-6609016-1|144|6EHG1-2|6609116-3|166|
|6ED2|1-6609016-0|144|6EHG8-2|1-1609117-6|166|
|6ED4|1-6609016-2|144|6EHGS1-2|1609988-3|166|
|6ED4C|1-6609016-4|144|6EHL1S|6609123-1|176|
|6ED8|1-6609016-3|144|6EHL1SC|6609123-2|176|
|6ED8C|1-6609016-5|144|6EHL1SCM|6609123-3|176|
|6EDK1|6609033-5|18|6EHL1SM|6609123-4|176|
|6EDK3|6609033-6|18|6EHL4|6609123-5|176|
|6EDL1S|1-6609122-9|176|6EHL4C|6609123-6|176|
|6EDL1SC|2-6609122-0|176|6EHL4CM|6609123-7|176|
|6EDL1SCM|2-6609122-1|176|6EHL4M|6609123-8|176|
276
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Part Number Index and Cross Reference**
|Catalog|TE|Page|Catalog|TE|Page|
|---|---|---|---|---|---|
|Number|Ordering Number|Number|Number|Ordering Number|Number|
|6EHQ1|6609054-5|37|6ESRM-P|1609078-1|201|
|6EHQ3|6609054-6|37|6ET1|6609046-4|80|
|6EHQ8|6609054-7|37|6ET3|6609046-5|80|
|6EHT1|6609053-5|40|6ET7|6609046-6|80|
|6EHT3|6609053-6|40|6EU1|6609045-2|84|
|6EHT7|6609053-7|40|6EUP|6609045-1|84|
|6EHT7M|6609053-8|40|6EXP|6609060-6|92|
|6EJH1|6609008-3|154|6FC10|6609069-1|30|
|6EJH2|1-6609008-0|154|6FCD10|6609070-1|119|
|6EJH8|3-6609008-0|154|6HJ4-2|6609126-1|172|
|6EJHP|1-6609008-1|154|6HJ4-4|6609126-2|172|
|6EJHS1|1-6609008-8|154|6IK1|1609973-4|46|
|6EJHS8|2-6609008-4|154|6J4|6609125-1|172|
|6EJM1|6609985-3|154|6J4-2|6609125-2|172|
|6EJM8|1-6609985-5|154|6MV1|6609056-2|54|
|6EJMS1|6609985-9|154|6RJ11-6L-B|6609213-2|248|
|6EJMS8|2-6609985-0|154|6VAQ3|6609057-3|12|
|6EJS1|1-6609006-2|154|6VAQ8F|6609058-3|12|
|6EJS8|3-6609006-9|154|6VAQ8FS|6609058-4|12|
|6EJT1|2-6609006-3|163|6VDK1|6609034-5|18|
|6EJT8|2-6609006-8|163|6VDK3|6609034-6|18|
|6EL1S|6609121-1|176|6VG1|6609051-1|35|
|6EL1SC|6609121-2|176|6VJ1|6609124-1|172|
|6EL1SCM|6609121-3|176|6VJ1-2|6609124-2|172|
|6EL1SM|6609121-4|176|6VM1|2-6609128-6|184|
|6EL4|6609121-5|176|6VM1C|2-6609128-7|184|
|6EL4C|6609121-6|176|6VM1S|2-6609128-8|184|
|6EL4CM|6609121-7|176|6VM1SC|2-6609128-9|184|
|6EL4M|6609121-8|176|6VM2|3-6609128-0|184|
|6EMC1|1-6609037-2|24|6VM2S|3-6609128-1|184|
|6EMC3|1-6609037-9|24|6VM4|3-6609128-3|184|
|6EOP|6609064-3|21|6VM4C|3-6609128-4|184|
|6EP1|6609037-5|27|6VM4S|3-6609128-5|184|
|6EP3|6609037-6|27|6VM4SC|3-6609128-7|184|
|6EQ1|6609048-5|58|6VN1|6609052-1|56|
|6EQ3|6609048-6|58|6VS1|6609042-2|68|
|6EQ8|6609048-7|58|6VSB1|1-1609034-2|71|
|6EQ8M|6609048-8|58|6VSK1|6609036-5|75|
|6ERK1|1-1609036-8|65|6VSK3|6609036-6|75|
|6ESB1|1-1609034-1|71|6VSK7|6609036-7|75|
|6ESK1|6609035-5|75|6VSK7M|6609036-8|75|
|6ESK3|6609035-6|75|6VV1|6609043-2|86|
|6ESK7|6609035-7|75|7BCF10|1609989-1|113|
|6ESK7M|6609035-8|75|7EP1|2-6609037-4|27|
|6ESRF-3|1609133-1|201|7EP3|2-6609037-5|27|
|6ESRFC3|1609133-2|201|10AFC6-A|1609990-1|236|
|6ESRM-3|1609133-3|201|10AFC6-B|1609990-2|236|
|6ESRMC2|1609133-4|201|10AYO1|6609066-3|111|
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
277
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Part Number Index and Cross Reference**
|Catalog|TE|Page|Catalog|TE|Page|
|---|---|---|---|---|---|
|Number|OrderingNumber|Number|Number|OrderingNumber|Number|
|10CBE1|1609112-1|130|10EH1|6609012-5|169|
|10CBS1|1609112-2|130|10EH3|6609012-6|169|
|10CE1|1609112-3|130|10EH4|6609013-5|169|
|10CFE1|1-6609113-3|130|10EH4C|6609013-6|169|
|10CFS1|1-6609113-4|130|10EHG1-2|6609116-4|166|
|10CHE1|1-6609114-3|130|10EHG8-2|6609116-5|166|
|10CHS1|1-6609114-4|130|10EHGS1-2|1609116-6|166|
|10CS1|1609112-8|130|10EHT1|6609053-9|40|
|10CUFE1|2-1609113-5|134|10EHT3|1-6609053-0|40|
|10CUFF1|2-1609114-5|134|10EJH1|6609008-4|154|
|10CUFS1|2-1609114-0|134|10EJH2|1-6609008-2|154|
|10DAF1|6609075-8|212|10EJH8|3-6609008-1|154|
|10DAFP|6609075-7|212|10EJHP|1-6609008-3|154|
|10DAS1|2-6609075-5|212|10EJHS1|1-6609008-9|154|
|10DFC6-C|1609992-1|239|10EJHS8|2-6609008-5|154|
|10EAH1|6609002-5|149|10EJM1|6609985-4|154|
|10EAS1|6609005-9|149|10EJM8|1-6609985-6|154|
|10EB1|6609020-9|15|10EJMS1|1-6609985-0|154|
|10EB3|1-6609020-0|15|10EJMS8|2-6609985-1|154|
|10EBF1|6609018-7|138|10EJS1|1-6609006-6|154|
|10EBF4|6609018-8|138|10EJS8|4-6609006-0|154|
|10EBH1|6609003-4|149|10EJT1|2-6609006-4|163|
|10EBS1|1-6609005-4|149|10EJT8|2-6609006-9|163|
|10EC1|1-1609017-3|141|10EK1|1-6609027-3|49|
|10ED1|1-6609016-6|144|10EK3|1-6609027-4|49|
|10ED1C|1-6609016-7|144|10EK7|1-6609027-5|49|
|10EDK1|6609033-7|18|10EK7M|1-6609027-6|49|
|10EDK3|6609033-8|18|10EMC1|1-6609037-3|24|
|10EDP|6609065-4|21|10EMC3|2-6609037-0|24|
|10EEA1|1-6609000-0|149|10EMC6|2-6609037-1|24|
|10EEA2|1-6609000-1|149|10EOP|6609064-4|21|
|10EEAP|1-6609000-2|149|10EP1|6609037-7|27|
|10EEB1|1-6609001-0|149|10EP3|6609037-8|27|
|10EEB2|1-6609001-1|149|10ER1|1-6609031-3|61|
|10EEBP|1-6609001-2|149|10ER3|1-6609031-4|61|
|10EEJ1|1-6609006-3|154|10ER7|1-6609031-5|61|
|10EEJ2|1-6609006-4|154|10ER7M|1-6609031-6|61|
|10EEJ8|3-6609006-5|154|10ERK1|2-1609089-5|65|
|10EEJP|1-6609006-5|154|10ESB1|1-1609034-3|71|
|10EF1F|6609015-7|160|10ESB6|1-1609034-4|71|
|10EF1FC|6609015-8|160|10ESK1|6609035-9|75|
|10EG1|6609050-2|35|10ESK3|1-6609035-0|75|
|10EGG1-1|3-1609115-4|166|10ESK7|1-6609035-1|75|
|10EGG1-2|3-1609115-3|166|10ESK7M|1-6609035-2|75|
|10EGG8-1|3-1609115-5|166|10ET1|6609046-7|80|
|10EGG8-2|3-1609115-6|166|10ET3|6609046-8|80|
|10EGS1-1|1609117-7|166|10FFA6-BA|1609991-1|230|
|10EGS1-2|1609117-8|166|10FFA6-CE|1609991-9|230|
For email, phone or live chat, please go to
278
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Part Number Index and Cross Reference**
|Catalog|TE|Page|Catalog|TE|Page|
|---|---|---|---|---|---|
|Number|Ordering Number|Number|Number|Ordering Number|Number|
|10FFA6-GJ|1-1609991-8|230|15CUE1|2-1609114-7|134|
|10FFD6-CA|1609993-1|233|15CUFE1|2-1609113-6|134|
|10FFD6-HE|1609993-7|233|15CUFF1|2-1609114-6|134|
|10MV1|6609056-3|54|15CUFS1|2-1609114-1|134|
|10VB1|6609021-9|15|15CUS1|2-1609114-9|134|
|10VB3|1-6609021-0|15|15DAF1|1-6609075-0|212|
|10VB6|1-6609021-2|15|15DAFP|6609075-9|212|
|10VDK1|6609034-7|18|15DAS1|2-6609075-9|212|
|10VDK3|6609034-8|18|15DCB10|4-6609074-1|218|
|10VG1|6609051-2|35|15DCB10B|4-6609074-3|218|
|10VK1|1-6609028-3|49|15DCB10BF|4-6609074-4|218|
|10VK3|1-6609028-4|49|15DCB10F|4-6609074-2|218|
|10VK6|1-6609028-8|49|15DCB6|2-6609074-1|218|
|10VK7|1-6609028-5|49|15DCB6B|2-6609074-3|218|
|10VK7M|1-6609028-6|49|15DCB6BF|2-6609074-4|218|
|10VN1|6609052-2|56|15DCB6F|2-6609074-2|218|
|10VR1|1-6609032-3|61|15DCF10|1-6609074-1|218|
|10VR3|1-6609032-4|61|15DCF10B|1-6609074-2|218|
|10VR6|1-6609032-5|61|15DCF6|6609074-1|218|
|10VR7|1-6609032-6|61|15DCF6B|6609074-2|218|
|10VR7M|1-6609032-7|61|15ED1|1-6609016-8|144|
|10VS1|6609042-3|68|15ED8|1-6609016-9|144|
|10VSB1|1-1609034-5|71|15EEJ1|1-6609006-7|154|
|10VSB6|1-1609034-6|71|15EEJ2|1-6609006-9|154|
|10VSK1|6609036-9|75|15EEJ8|3-6609006-6|154|
|10VSK3|1-6609036-0|75|15EEJP|2-6609006-0|154|
|10VSK7|1-6609036-1|75|15EF1F|6609015-9|160|
|10VSK7M|1-6609036-2|75|15EH4|6609013-7|169|
|10VT1|6609047-1|80|15EHT1|1-6609053-1|40|
|10VT3|6609047-2|80|15EHT6|1-6609053-2|40|
|10VV1|6609043-3|86|15EJH1|6609008-5|154|
|10VW1|6609044-3|86|15EJH2|1-6609008-4|154|
|12EP1|2-6609037-6|27|15EJH8|3-6609008-2|154|
|12EP3|2-6609037-7|27|15EJHP|1-6609008-5|154|
|12FC10|6609069-2|30|15EJHS1|2-6609008-0|154|
|12FC10B|1609976-3|30|15EJHS8|2-6609008-6|154|
|12FCD10|6609070-2|119|15EJM1|6609985-5|154|
|12FCD10B|6609974-4|119|15EJM8|1-6609985-7|154|
|15CBE1|1-1609112-4|130|15EJMS1|1-6609985-1|154|
|15CBS1|1-1609112-3|130|15EJMS8|2-6609985-2|154|
|15CE1|1-1609112-2|130|15EJS1|1-6609006-8|154|
|15CS1|1-1609112-1|130|15EJS8|4-6609006-1|154|
|15CU10BS1|1-1609112-7|134|15EJT1|2-6609006-5|163|
|15CU10S1|1-1609112-6|134|15EJT8|3-6609006-0|163|
|15CU15BS1|1-1609112-9|134|15EMC1|1-6609037-4|24|
|15CU15S1|1-1609112-8|134|15EMC3|2-6609037-2|24|
|15CUBE1|2-1609114-8|134|15EMC6|2-6609037-3|24|
|15CUBS1|1-1609112-5|134|15ERK1|2-1609089-6|65|
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
279
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Part Number Index and Cross Reference**
|Catalog|TE|Page|Catalog|TE|Page|
|---|---|---|---|---|---|
|Number|OrderingNumber|Number|Number|OrderingNumber|Number|
|15ET1|6609046-9|80|15SRBS8-S|3-6609987-0|204|
|15ET6|1-6609046-0|80|15SRBS8-T|3-6609987-1|204|
|15SRB1|6609987-9|204|15SRBS8-W|3-6609987-2|204|
|15SRB1-Q|6609987-1|204|15SRBS8-X|3-6609987-3|204|
|15SRB1-R|6609987-2|204|15SRBX8|5-1609987-6|204|
|15SRB1-S|6609987-3|204|15SRBX8-Q|5-1609987-7|204|
|15SRB1-T|6609987-4|204|15SRBX8-R|5-1609987-8|204|
|15SRB1-W|6609987-5|204|15SRBX8-S|5-1609987-9|204|
|15SRB1-X|6609987-6|204|15SRBX8-T|6-1609987-0|204|
|15SRB1-Y|6609987-7|204|15SRBX8-W|6-1609987-1|204|
|15SRB1-Z|6609987-8|204|15SRBX8-X|6-1609987-2|204|
|15SRB2|5-6609987-4|204|15SRBY8|6-1609987-5|204|
|15SRB2-Q|4-6609987-6|204|15SRBY8-Q|6-1609987-6|204|
|15SRB2-R|4-6609987-7|204|15SRBY8-R|6-1609987-7|204|
|15SRB2-S|4-6609987-8|204|15SRBY8-S|6-1609987-8|204|
|15SRB2-T|4-6609987-9|204|15SRBY8-T|6-1609987-9|204|
|15SRB2-W|5-6609987-0|204|15SRBY8-W|7-1609987-0|204|
|15SRB2-X|5-6609987-1|204|15SRBY8-X|7-1609987-1|204|
|15SRB2-Y|5-6609987-2|204|15VT1|6609047-3|80|
|15SRB2-Z|5-6609987-3|204|15VT6|6609047-4|80|
|15SRB8|1-6609987-8|204|16AFC6-B|1609990-3|236|
|15SRB8-Q|1-6609987-0|204|16AFC6-C|1609990-4|236|
|15SRB8-R|1-6609987-1|204|16AFC6-G|1609990-5|236|
|15SRB8-S|1-6609987-2|204|16AFC6-H|1609990-6|236|
|15SRB8-T|1-6609987-3|204|16AYA10|6609977-1|104|
|15SRB8-W|1-6609987-4|204|16AYA6|6609068-1|104|
|15SRB8-X|1-6609987-5|204|16AYA6A|6609068-2|104|
|15SRBP|4-6609987-5|204|16AYC10B|6609067-1|108|
|15SRBP-Q|3-6609987-7|204|16BCF10|1609989-2|113|
|15SRBP-R|3-6609987-8|204|16DFC6-C|1609992-2|239|
|15SRBP-S|3-6609987-9|204|16DFC6-G|1609992-3|239|
|15SRBP-T|4-6609987-0|204|16DFC6-H|1609992-4|239|
|15SRBP-W|4-6609987-1|204|16DFC6-N|1609992-5|239|
|15SRBP-X|4-6609987-2|204|16FC10|6609069-3|30|
|15SRBP-Y|4-6609987-3|204|16FC10B|1609976-1|30|
|15SRBP-Z|4-6609987-4|204|16FCD10|6609070-3|119|
|15SRBS1|2-6609987-7|204|16FCD10B|6609974-5|119|
|15SRBS1-Q|1-6609987-9|204|16FFA6-CA|1609991-2|230|
|15SRBS1-R|2-6609987-0|204|16FFA6-DG|1-1609991-1|230|
|15SRBS1-S|2-6609987-1|204|16FFA6-HN|1-1609991-9|230|
|15SRBS1-T|2-6609987-2|204|16FFD6-CA|1609993-2|233|
|15SRBS1-W|2-6609987-3|204|16FFD6-HE|1609993-8|233|
|15SRBS1-X|2-6609987-4|204|16IK10|6609973-1|46|
|15SRBS1-Y|2-6609987-5|204|16WGA1|2-6609089-4|89|
|15SRBS1-Z|2-6609987-6|204|16WGA3|7-6609089-6|89|
|15SRBS8|3-6609987-6|204|16WGA7|3-1609090-8|89|
|15SRBS8-Q|2-6609987-8|204|16WGB1|4-6609089-0|89|
|15SRBS8-R|2-6609987-9|204|16WGB3|7-6609089-7|89|
280
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Part Number Index and Cross Reference**
|Catalog|TE|Page|Catalog|TE|Page|
|---|---|---|---|---|---|
|Number|Ordering Number|Number|Number|Ordering Number|Number|
|16WGB7|3-1609090-9|89|20VK6|1-6609028-9|49|
|16WGC1|4-6609089-1|89|20VP1|6609038-1|27|
|16WGC3|7-6609089-8|89|20VP6|6609038-2|27|
|16WGC7|4-1609090-0|89|20VQ1|6609049-5|58|
|16WGD1|4-6609089-6|89|20VR1|1-6609032-8|61|
|16WGD3|7-6609089-9|89|20VR6|1-6609032-9|61|
|16WGD7|4-1609090-1|89|20VS1|6609042-4|68|
|16WGE1|4-6609089-7|89|20VS6|6609042-5|68|
|16WGE3|8-6609089-0|89|20VSB1|1-1609034-9|71|
|16WGE7|4-1609090-2|89|20VSB6|2-1609034-0|71|
|16WGF1|4-6609089-8|89|20VSK6|1-6609036-3|75|
|16WGF3|8-6609089-1|89|20VT1|6609047-5|80|
|16WGF7|4-1609090-3|89|20VT6|6609047-6|80|
|20AFC6-B|1609990-7|236|20VV1|6609043-4|86|
|20AYO1|6609066-4|111|20VV6|6609043-5|86|
|20AYP6C|6609072-1|99|20VW1|6609044-4|86|
|20AYT6C|6609073-1|99|20VW6|6609044-5|86|
|20EB1|1-6609020-1|15|25AYA6|6609068-3|104|
|20EDK1|6609033-9|18|25AYA6A|6609977-2|104|
|20EEJ1|6609007-3|154|25AYC10B|6609068-4|108|
|20EEJ8|6609007-6|154|25FC10|6609069-4|30|
|20EJH1|6609009-4|154|25FC10B|6609976-2|30|
|20EJH8|6609009-5|154|25FCD10|6609070-4|119|
|20EJS1|6609007-5|154|25FCD10B|6609974-9|119|
|20EJS8|6609007-7|154|30AYP6C|6609072-2|99|
|20EJT1|6609007-8|163|30AYT6C|6609073-2|99|
|20EJT8|3-6609006-1|163|30BCF10|1609989-3|113|
|20EK1|1-6609027-7|49|30DCB10|4-6609074-5|218|
|20EMC1|1-6609037-5|24|30DCB10B|4-6609074-7|218|
|20EMC6|1-6609037-7|24|30DCB10BF|4-6609074-8|218|
|20EP1|6609037-9|27|30DCB10F|4-6609074-6|218|
|20EP6|1-6609037-0|27|30DCB6|2-6609074-5|218|
|20EQ1|6609048-9|58|30DCB6B|2-6609074-7|218|
|20ER1|1-6609031-7|61|30DCB6BF|2-6609074-8|218|
|20ERK1|2-1609089-7|65|30DCB6F|2-6609074-6|218|
|20ESB1|1-1609034-7|71|30DCF10|1-6609074-3|218|
|20ESB6|1-1609034-8|71|30DCF10B|1-6609074-4|218|
|20ESK6|1-6609035-3|75|30DCF6|6609074-3|218|
|20ESRM-3|4-1609134-7|201|30DCF6B|6609074-4|218|
|20ESRMC2|4-1609134-8|201|30EMC6|1-6609037-6|24|
|20ET1|1-6609046-1|80|30ESB6|2-1609034-1|71|
|20ET6|1-6609046-2|80|30ESK6|1-6609035-4|75|
|20MV1|6609056-4|54|30ESK6C|1-6609035-5|75|
|20VB1|1-6609021-1|15|30VB6|1-6609021-4|15|
|20VB6|1-6609021-3|15|30VK6|2-6609028-0|49|
|20VDK1|6609034-9|18|30VK6C|2-6609028-1|49|
|20VDK6|1-6609034-0|18|30VSB6|2-1609034-2|71|
|20VK1|1-6609028-7|49|30VSK6|1-6609036-4|75|
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
281
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Part Number Index and Cross Reference**
|Catalog|TE|Page|Catalog|TE|Page|
|---|---|---|---|---|---|
|Number|OrderingNumber|Number|Number|OrderingNumber|Number|
|30VSK6C|1-6609036-5|75|60DBPL9|5-1609075-1|214|
|32AFC6-B|1609990-8|236|60DBR|5-1609075-6|214|
|32AFC6-C|1609990-9|236|60DBRL1|6-1609075-4|214|
|32AFC6-F|1-1609990-1|236|60DBRL3|6-1609075-5|214|
|32AFC6-G|1-1609990-2|236|60DBX8|4-1609075-7|214|
|32AFC6-H|1-1609990-3|236|60DCB10|4-6609074-9|218|
|32DFC6-C|1609992-6|239|60DCB10B|5-6609074-1|218|
|32DFC6-G|1609992-7|239|60DCB10BF|5-6609074-2|218|
|32DFC6-H|1609992-8|239|60DCB10F|5-6609074-0|218|
|32DFC6-N|1609992-9|239|60DCB6|2-6609074-9|218|
|32FFA6-CA|1609991-3|230|60DCB6B|3-6609074-1|218|
|32FFA6-DH|1-1609991-2|230|60DCB6BF|3-6609074-2|218|
|32FFA6-HN|2-1609991-1|230|60DCB6F|3-6609074-0|218|
|32FFD6-CA|1609993-3|233|60DCF10|1-6609074-5|218|
|32FFD6-HE|1609993-9|233|60DCF10B|1-6609074-6|218|
|35IK10|6609973-2|46|60DCF6|6609074-5|218|
|36AYA10|6609068-6|104|60DCF6B|6609074-6|218|
|36AYA6|6609068-5|104|60VK6|2-6609028-5|49|
|36AYA6A|6609977-3|104|60VS6|1609042-6|68|
|36AYC10B|6609067-2|108|63ADT6|1609071-2|101|
|36FC10|6609069-5|30|63ADT6S|1609071-1|101|
|36FC10B|1609976-4|30|63AFC6-C|1-1609990-4|236|
|36FCD10|6609070-5|119|63AFC6-G|1-1609990-5|236|
|36FCD10B|1-6609974-1|119|63AFC6-H|1-1609990-6|236|
|40VK6|2-6609028-3|49|63AYA10|1609977-5|104|
|40VK6C|2-6609028-4|49|63AYA6A|6609977-8|104|
|40VSK6|1-6609036-6|75|63AYC10B|6609067-3|108|
|42BCF10|1609989-4|113|63DFC6-C|1-1609992-1|239|
|45AYP6C|6609072-3|99|63DFC6-G|1-1609992-2|239|
|45AYT6C|6609073-3|99|63DFC6-H|1-1609992-3|239|
|50AYA6|6609068-7|104|63DFC6-N|1-1609992-4|239|
|50AYA6A|6609068-8|104|63FFA6-GB|1609991-4|230|
|50FC10|6609069-6|30|63FFA6-JK|1-1609991-3|230|
|50FC10B|6609069-7|30|63FFA6-NP|2-1609991-2|230|
|50FCD10|6609070-6|119|63FFD6-HB|1609993-4|233|
|50FCD10B|1-6609974-3|119|63FFD6-NH|1-1609993-1|233|
|50FCD10BS|1-6609974-6|119|75BCF10|1609989-6|113|
|50FCD10BS|1-6609974-6|119|80AYC10B|6609067-4|108|
|50IK10|1609973-5|46|80FCD10B|6609070-7|119|
|55BCF10|1609989-5|113|80FCD10BS|1-6609974-7|119|
|60AYP6C|6609072-4|99|80IK10|6609973-3|46|
|60AYT6C|6609073-4|99|100ADT6|1609071-4|101|
|60DB8|4-1609075-4|214|100ADT6S|1609071-3|101|
|60DBF8|4-1609075-5|214|100AFC6-H|1-1609990-8|236|
|60DBJ8|4-1609075-6|214|100AFC6-H|1-1609990-8|236|
|60DBP|5-1609075-7|214|100AFC6-K|1-1609990-9|236|
|60DBPL1|4-1609075-9|214|100AFC6-N|2-1609990-1|236|
|60DBPL3|5-1609075-0|214|100AYA6A|6609977-7|104|
For email, phone or live chat, please go to
282
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Part Number Index and Cross Reference**
|Catalog|TE|Page|Catalog|TE|Page|
|---|---|---|---|---|---|
|Number|Ordering Number|Number|Number|Ordering Number|Number|
|100BCF10|1609989-7|113|180FCD10B|1-6609070-0|119|
|100DCB10|5-6609074-3|218|180FCD10BS|2-6609974-1|119|
|100DCB10B|5-6609074-5|218|200ADT6|1609071-8|101|
|100DCB10BF|5-6609074-6|218|200ADT6S|1609071-7|101|
|100DCB10F|5-6609074-4|218|200AFC6-H|2-1609990-2|236|
|100DCB6|3-6609074-3|218|200AFC6-K|2-1609990-3|236|
|100DCB6B|3-6609074-5|218|200AFC6-N|2-1609990-4|236|
|100DCB6BF|3-6609074-6|218|200AFC6-P|2-1609990-5|236|
|100DCB6F|3-6609074-4|218|200AYC10B|1609067-8|108|
|100DCF10|1-6609074-7|218|200DFC6-H|1-1609992-9|239|
|100DCF10B|1-6609074-8|218|200DFC6-N|2-1609992-1|239|
|100DCF6|6609074-7|218|200DFC6-P|2-1609992-2|239|
|100DCF6B|6609074-8|218|200DFC6-R|2-1609992-3|239|
|100DFC6-G|1-1609992-5|239|200FFA6-HD|1609991-6|230|
|100DFC6-H|1-1609992-6|239|200FFA6-NP|1-1609991-5|230|
|100DFC6-N|1-1609992-7|239|200FFA6-PP|2-1609991-4|230|
|100DFC6-P|1-1609992-8|239|200FFD6-ND|1609993-6|233|
|100FFA6-HC|1609991-5|230|200FFD6-RP|1-1609993-3|233|
|100FFA6-NP|1-1609991-4|230|230FCD10B|1-6609070-2|119|
|100FFA6-PP|2-1609991-3|230|230FCD10BS|3-6609974-6|119|
|100FFD6-NC|1609993-5|233|250AFC6-H|2-1609990-6|236|
|100FFD6-PK|1-1609993-2|233|250AFC6-K|2-1609990-7|236|
|110AYC10B|6609067-5|108|250AFC6-N|2-1609990-8|236|
|110FCD10B|6609070-8|119|250AFC6-P|2-1609990-9|236|
|110FCD10BS|1-6609974-8|119|250DFC6-P|2-1609992-4|239|
|125DCB10|5-6609074-7|218|250DFC6-Q|2-1609992-5|239|
|125DCB10B|5-6609074-9|218|250DFC6-T|2-1609992-6|239|
|125DCB10BF|6-6609074-0|218|250FFA6-HF|1609991-7|230|
|125DCB10F|5-6609074-8|218|250FFA6-NP|1-1609991-6|230|
|125DCB6|3-6609074-7|218|250FFA6-PP|2-1609991-5|230|
|125DCB6B|3-6609074-9|218|300AFC6-H|3-1609990-1|236|
|125DCB6BF|4-1609074-0|218|300AFC6-K|3-1609990-2|236|
|125DCB6F|3-6609074-8|218|300AFC6-N|3-1609990-3|236|
|125DCF10|1-6609074-9|218|300AFC6-P|3-1609990-4|236|
|125DCF10B|2-6609074-0|218|300CFN12|1609978-1|116|
|125DCF6|6609074-9|218|300DFC6-P|2-1609992-7|239|
|125DCF6B|1-6609074-0|218|300DFC6-Q|2-1609992-8|239|
|130BCF10|1609989-8|113|300DFC6-T|2-1609992-9|239|
|150AYC10B|6609067-6|108|300FFA6-HF|1609991-8|230|
|150AYC10B-95|1609067-7|108|300FFA6-NP|1-1609991-7|230|
|150FCD10B|6609070-9|119|300FFA6-PP|2-1609991-6|230|
|150FCD10B-95|3-6609974-3|119|400CFN12|1-1609979-7|116|
|150FCD10BS|2-6609974-0|119|500CFN12|6609978-3|116|
|150FCD10BS-95|1-6609974-9|119|600CFN12|6609978-4|116|
|160ADT6|1609071-6|101|PE000DD3D|6609110-1|223|
|160ADT6S|1609071-5|101|PE000DD6D|6609110-3|223|
|180AYC10B|6609977-6|108|PE000DDXD|6609110-5|223|
|180BCF10|1609989-9|113|PE000SD3D|6609110-2|223|
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
283
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Part Number Index and Cross Reference**
|Catalog|TE|Page|Catalog|TE|Page|
|---|---|---|---|---|---|
|Number|OrderingNumber|Number|Number|OrderingNumber|Number|
|PE000SD6D|6609110-4|223|RJ45-6L1-B|5-6609208-0|247|
|PE000SDXD|6609110-6|223|RJ45-6L1-S|4-6609208-9|247|
|PS000DD3D|6609111-3|223|RJ45-6L2-B|5-6609208-2|247|
|PS000DD6D|6609111-5|223|RJ45-6L2-S|5-6609208-1|247|
|PS000DDXD|6609111-7|223|RJ45-6L-B|4-6609208-8|247|
|PS000SD3D|6609111-4|223|RJ45-6LC1-B|2-6609209-7|249|
|PS000SD6D|6609111-6|223|RJ45-6LC1-S|2-6609209-6|249|
|PS000SDXD|6609111-8|223|RJ45-6LC2-B|2-6609209-9|249|
|RJ11-2L2-B|1-1609208-2|247|RJ45-6LC2-S|2-6609209-8|249|
|RJ11-2L-B|6609208-4|247|RJ45-6L-S|4-6609208-7|247|
|RJ11-2LC1-B|6609209-2|249|RJ45-6X|1-6609214-0|252|
|RJ11-2LC1-S|6609209-1|249|RJ45-8L1-B|5-6609208-7|247|
|RJ11-2LC2-B|6609209-4|249|RJ45-8L1-S|5-6609208-5|247|
|RJ11-2LC2-S|6609209-3|249|RJ45-8L2-B|6-6609208-0|247|
|RJ11-2L-S|6609208-1|247|RJ45-8L2-S|5-6609208-9|247|
|RJ11-2X|6609214-1|252|RJ45-8L-B|5-6609208-4|247|
|RJ11-4L1-B|2-1609208-2|247|RJ45-8LC1-B|3-6609209-3|249|
|RJ11-4L1-S|2-6609208-1|247|RJ45-8LC1-S|3-6609209-0|249|
|RJ11-4L2-B|2-6609208-7|247|RJ45-8LC2-B|4-6609209-1|249|
|RJ11-4L2-S|2-6609208-5|247|RJ45-8LC2-S|3-6609209-6|249|
|RJ11-4L-B|1-6609208-7|247|RJ45-8LCT1-B|1-6609211-1|250|
|RJ11-4LC1-B|6609209-8|249|RJ45-8LCT1-S|1-6609211-0|250|
|RJ11-4LC1-S|6609209-6|249|RJ45-8LCT2-B|1-6609211-3|250|
|RJ11-4LC2-B|1-6609209-3|249|RJ45-8LCT2-S|1-6609211-2|250|
|RJ11-4LC2-S|1-6609209-0|249|RJ45-8L-S|5-6609208-3|247|
|RJ11-4L-S|1-6609208-5|247|RJ45-8N3-B|1-6609212-3|251|
|RJ11-4X|6609214-3|252|RJ45-8N3-S|1-6609212-4|251|
|RJ11-6L1-B|4-6609208-0|247|RJ45-8N4-B|1-6609212-5|251|
|RJ11-6L1-S|3-6609208-8|247|RJ45-8N4-S|1-6609212-6|251|
|RJ11-6L2-B|4-6609208-5|247|RJ45-8N-B|1-6609212-0|251|
|RJ11-6L2-S|4-6609208-3|247|RJ45-8N-S|1-6609212-2|251|
|RJ11-6L-B|3-6609208-1|247|RJ45-8X|1-6609214-1|252|
|RJ11-6LC1-B|1-6609209-8|249|RJ45-8X1|1-6609210-4|252|
|RJ11-6LC1-S|1-6609209-6|249|RJ45-8X2|1-6609214-3|252|
|RJ11-6LC2-B|2-6609209-1|249|RJ45-8Z|6609215-4|253|
|RJ11-6LC2-S|2-6609209-0|249|RJ45-8Z3|6609215-5|253|
|RJ11-6LCT1-B|6609211-4|250|RJ45-8Z4|6609215-6|253|
|RJ11-6LCT1-S|6609211-1|250|RJH-4L-B|6-6609208-1|247|
|RJ11-6LCT2-B|6609211-8|250||||
|RJ11-6LCT2-S|6609211-6|250||||
|RJ11-6L-S|2-6609208-9|247||||
|RJ11-6N3-B|6609212-6|251||||
|RJ11-6N4-B|6609212-8|251||||
|RJ11-6N-B|6609212-4|251||||
|RJ11-6X|6609214-5|252||||
|RJ11-6Z|6609215-1|253||||
|RJ11-6Z3|6609215-2|253||||
|RJ11-6Z4|6609215-3|253||||
284
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Engineering Notes**
285
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **North American Sales Representatives**
|ALABAMA|||IDAHO|||
|---|---|---|---|---|---|
|CARTWRIGHT & BEAN, INC.|HUNTSVILLE, AL|800-242-5876|HALBAR-RTS, INC.|KIRKLAND, WA|425-893-8400|
|ALASKA|||INDIANA|||
|TE CONNECTIVITY|MUNDELEIN, IL|847-573-6504|RATHSBURG ASSOCIATES|CARMEL, IN|317-818-7055|
|ARIZONA|||IOWA|||
|LUSCOMBE ENGINEERING|PHOENIX, AZ|602-678-1955|RATHSBURG ASSOCIATES|BLOOMINGTON, MN|952-893-1400|
|ARKANSAS|||KANSAS|||
|ELECTRA REPS|PLANO, TX|972-599-2130|RATHSBURG ASSOCIATES|OLATHE, KS|913-829-2800|
|CALIFORNIA|||KENTUCKY|||
|LUSCOMBE ENGINEERING (SOUTH)|LUSCOMBE ENGINEERING (SOUTH)<br>CAMARILLO, CA|805-987-4880|RATHSBURG ASSOCIATES|EASTERN|248-615-4000|
|LUSCOMBE ENGINEERING (SOUTH)|LUSCOMBE ENGINEERING (SOUTH)<br>COSTA MESA, CA|714-546-4880|RATHSBURG ASSOCIATES|WESTERN|317-818-7055|
|LUSCOMBE ENGINEERING (SOUTH)<br>STRAUBE ASSOCIATES (NORTH)|LUSCOMBE ENGINEERING (SOUTH)<br>SAN DIEGO, CA<br>MOUNTAIN VIEW, CA|858-385-2655<br>650-969-6060|LOUISIANA|||
|CANADA|||ELECTRA REPS|PLANO, TX|972-599-2130|
|WEISS COMPANY|MONTREAL|514-337-6769|MAINE|||
|WEISS COMPANY|OTTAWA|613-599-8787|CONTI-YOUNGER ASSOCIATES|MARLBORO, MA|508-485-7204|
|WEISS COMPANY|TORONTO|905-238-9548||||
|WEISS COMPANY|VANCOUVER|604-276-8735|MARYLAND|||
|COLORADO|||ASTROREP MID-ATLANTIC, INC.|DOYLESTOWN, PA|267-880-6321|
|STRAUBE ASSOCIATES ROCKY|||MASSACHUSETTS|||
|MOUNTAINS, INC.|WESTMINSTER, CO|303-426-0890|CONTI-YOUNGER ASSOCIATES|MARLBORO, MA|508-485-7204|
|CONNECTICUT|||MEXICO|||
|CONTI-YOUNGER ASSOCIATES|MARLBORO, MA|508-485-7204|TE CONNECTIVITY|MUNDELEIN, IL|847-573-6504|
|DELAWARE|||MICHIGAN|||
|ASTROREP MID-ATLANTIC, INC.|DOYLESTOWN, PA|267-880-6321|RATHSBURG ASSOCIATES|NOVI, MI|248-615-4000|
|DISTRICT OF COLUMBIA|||MINNESOTA|||
|ASTROREP MID-ATLANTIC, INC.|DOYLESTOWN, PA|267-880-6321|RATHSBURG ASSOCIATES|BLOOMINGTON, MN|952-893-1400|
|FLORIDA|||MISSISSIPPI|||
|CBX ELECTRONICS|CASSELBERRY, FL|407-774-9100|CARTWRIGHT & BEAN, INC.|HUNTSVILLE, AL|800-242-5876|
|GEORGIA|||MISSOURI|||
|CARTWRIGHT & BEAN, INC.|NORCROSS, GA|800-242-5876|RATHSBURG ASSOCIATES|ST. LOUIS, MO|636-946-1001|
|ILLINOIS|||MONTANA|||
|RATHSBURG ASSOCIATES (NORTH)|ITASCA, IL|630-625-5100|HALBAR-RTS, INC.|KIRKLAND, WA|425-893-8400|
|RATHSBURG ASSOCIATES (SOUTH)|ST. LOUIS, MO|636-946-1001||||
286
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **North American Sales Representatives**
|NEBRASKA|||||SOUTH CAROLINA|||
|---|---|---|---|---|---|---|---|
|RATHSBURG ASSOCIATES|||OLATHE, KS|913-829-2800|CARTWRIGHT & BEAN, INC.|CHARLOTTE, NC|800-242-5876|
|NEVADA|||||SOUTH DAKOTA|||
|STRAUBE ASSOCIATES||MOUNTAIN VIEW, CA||650-969-6060|RATHSBURG ASSOCIATES|BLOOMINGTON, MN|952-893-1400|
|LUSCOMBE ENGINEERING (LAS VEGAS)<br>NEW HAMPSHIRE|||LUSCOMBE ENGINEERING (LAS VEGAS)<br>PHOENIX, AZ|602-678-1955|TENNESSEE<br>CARTWRIGHT & BEAN (EAST)|NORCROSS, GA|800-242-5876|
|CONTI-YOUNGER ASSOCIATES|||MARLBORO, MA|508-485-7204|CARTWRIGHT & BEAN (WEST)|HUNTSVILLE, AL|800-242-5876|
|NEW JERSEY|||||TEXAS|||
|ASTROREP MID-ATLANTIC, INC.|||||ELECTRA REPS|PLANO, TX|972-599-2130|
|(SOUTH)||DOYLESTOWN, PA||267-880-6321|ELECTRA REPS|AUSTIN|512-249-1101|
|ASTROREP, INC. (NORTH)|||BABYLON, NY|631-422-2500|ELECTRA REPS|HOUSTON|281-516-1122|
|NEW MEXICO|||||LUSCOMBE ENGINEERING (EL PASO)|LUSCOMBE ENGINEERING (EL PASO)<br>EL PASO, TX|602-678-1955|
|LUSCOMBE ENGINEERING|||PHOENIX, AZ|602-678-1955|UTAH<br>STRAUBE ASSOCIATES ROCKY|||
|NEW YORK|||||MOUNTAINS, INC.|WESTMINSTER, CO|303-426-0890|
|EMPIRE TECHNICAL ASSOCIATES||||||||
|(UPSTATE)||SKANEATELES, NY||315-685-5703|VERMONT|||
|ASTROREP INC.|||BABYLON, NY|631-422-2500|CONTI-YOUNGER ASSOCIATES|MARLBORO, MA|508-485-7204|
|NORTH CAROLINA|||||VIRGINIA|||
|CARTWRIGHT & BEAN, INC. (WEST)|||CHARLOTTE, NC|800-242-5876|ASTROREP MID-ATLANTIC, INC.|DOYLESTOWN, PA|267-880-6321|
|CARTWRIGHT & BEAN, INC. (EAST)<br>NORTH DAKOTA|||RALEIGH, NC|800-242-5876|WASHINGTON<br>HALBAR-RTS, INC.|KIRKLAND, WA|425-893-8400|
|RATHSBURG ASSOCIATES<br>OHIO||BLOOMINGTON, MN||952-893-1400|WEST VIRGINIA<br>RATHSBURG ASSOCIATES|COLUMBUS, OH|248-615-4000|
|RATHSBURG ASSOCIATES<br>OKLAHOMA|||COLUMBUS, OH|248-615-4000|WISCONSIN<br>RATHSBURG ASSOCIATES|MUSKEGO, WI|262-679-8250|
|ELECTRA REPS|||PLANO, TX|972-599-2130|RATHSBURG ASSOCIATES|HARTFORD, WI|262-670-6513|
|OREGON|||||WYOMING|||
|HALBAR-RTS, INC.|||BEAVERTON, OR|503-624-5741|STRAUBE ASSOCIATES ROCKY|||
|PENNSYLVANIA|||||MOUNTAINS, INC.|WESTMINSTER, CO|303-426-0890|
|ASTROREP MID-ATLANTIC, INC. (EAST) DOYLESTOWN, PA|ASTROREP MID-ATLANTIC, INC. (EAST) DOYLESTOWN, PA||ASTROREP MID-ATLANTIC, INC. (EAST) DOYLESTOWN, PA|267-880-6321||||
|RATHSBURG ASSOCIATES (WEST)|||PITTSBURGH, PA|248-615-4000||||
|PUERTO RICO||||||||
|CBX ELECTRONICS|ALTAMONTE SPRINGS, FL|||407-774-9100||||
|RHODE ISLAND||||||||
|CONTI-YOUNGER ASSOCIATES|||MARLBORO, MA|508-485-7204||||
287
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to
**te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## **Authorized Corcom Product Distributors and Resellers**
|All American<br>www.allamerican.com<br>1-800-573-ASAP|Hammond Electronics<br>www.hammondelec.com<br>1-800-929-2677|
|---|---|
|Allied Electronics, Inc.<br>www.alliedelec.com<br>1-800-433-5700|Heilind Electronics<br>www.heilind.com<br>1-800-400-7041|
|Arrow Electronics<br>www.arrow.com<br>1-800-777-2776|Marsh Electronics<br>www.marshelectronics.com<br>1-800-236-8327|
|Avnet<br>www.avnet.com<br>US: 1-800-332-8638|Master Distributors<br>www.masterdistributors.com<br>1-888-473-5297|
|Carlton Bates Company<br>www.carlton-bates.com<br>1-866-600-6040|Mouser Electronics<br>www.mouser.com<br>1-800-346-6873|
|Digi-Key Corporation<br>www.digikey.com<br>1-800-344-4539|Newark Electronics<br>www.newark.com<br>1-800-463-9275|
|Electro Sonic<br>www.e-sonic.com<br>1-800-567-6642|Norvell Electronics<br>www.norvell.com<br>1-800-893-0593|
|Future Electronics<br>www.futureelectronics.com<br>US & Canada: 1-800-FUTURE-1 (388-8731)|Sager Electronics<br>www.sager.com<br>1-800-SAGER-800|
|Genie Group<br>www.geniegroup.com<br>1-615-771-9412|Simcona Electronics<br>www.simcona.com<br>US: 1-800-274-6266<br>Canada: 1-519-652-1130|
|Gopher Electronics<br>www.gopherelectronics.com<br>1-800-592-9519|TTI Inc.<br>www.ttiinc.com<br>1-800-CALL-TTI|
288
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
Catalog: 1654001 Issue Date: 06.2011
Corcom Product Guide
## Global Contacts
## Americas
Argentina – Buenos Aires Phone: +54-11-4733-2200 Fax: +54-11-4733-2211
Brasil – São Paulo Phone: +55-11-2103-6000 Fax: +55-11-2103-6030
Chile – Santiago Phone: +56-2-345-0361 Fax: +56-2-223-1477
Canada – Toronto
Phone: +905-475-6222 Fax: +905-474-5520 Product Information Center: Phone: +905-470-4425 Fax: +905-474-5525
Colombia – Bogota Phone: +57-1-319-8959 Fax: +57-1-319-8960
Mexico – Mexico City Phone: +52-55-1106-0800 +01-800-733-8926 Fax: +52-55-1106-0901
For Latin/South American Countries not shown Phone: +54-11-4733-2015 Fax: +54-11-4733-2083
United States
Harrisburg, PA Phone: +1-717-564-0100 Fax: +1-717-986-7575 Product Information Center: Phone: +1-800-522-6752 Fax: +1-717-986-7575 Mundelein, IL Phone: +1-847-680-7400 Fax: +1-847-680-8169
## Asia/Pacific
Australia – Sydney Phone: +61-2-9554-2600 Fax: +61-2-9502-2556 Product Information Center: Phone: +61-2-9840-8200 Fax: +61-2-9634-6188
India – Bangalore Phone: +91-80-285-40800 Fax: +91-80-285-40820
Indonesia – Jakarta Phone: +65-6482-0311 Fax: +65-6482-1012
Japan – Kawasaki, Kanagawa Phone: +81-44-844-8111 Fax: +81-44-812-3207 Product Information Center: Phone: +81-44-844-8013 Fax: +81-44-812-3200
Korea – Seoul Phone: +82-2-3415-4500 Fax: +82-2-3486-3810
Malaysia – Selangor Phone: +60-3-7805-3055 Fax: +60-3-7805-3066
New Zealand – Auckland Phone: +64-9-634-4580 Fax: +64-9-634-4586
Philippines – Makati City Phone: +632-848-0171 Fax: +632-867-8661
People’s Republic of China Hong Kong Phone: +852-2735-1628 Fax: +852-2735-0243 Shanghai Phone: +86-21-2407-1588 Fax: +86-21-2407-1599
Singapore – Singapore Phone: +65-6482-0311 Fax: +65-6482-1012
Taiwan – Taipei Phone: +886-2-8768-2788 Fax: +886-2-8768-2268
Thailand – Bangkok Phone: +66-2-955-0500 Fax: +66-2-955-0505
Vietnam – Ho Chi Minh City Phone: +84-8-930-5546 Fax: +84-8-930-3443
## Europe/Middle East/Africa
Austria – Vienna Phone: +43-1-905-60-0 Fax: +43-1-905-60-1333 Product Information Center: Phone: +43-1-905-60-1228 Fax: +43-1-905-60-1333
Belarus – Minsk Phone: +375 17 237 47 94 Fax: +375 17 237 47 94
Belgium – Kessel-Lo Phone: +32-16-352-300 Fax: +32-16-352-355
Bulgaria – Sofia Phone: +359-2-971-2152 Fax: +359-2-971-2153
Czech Republic and Slovakia Czech Republic – Kurim Phone: +420-541-162-111 Fax: +420-541-162-223 Product Information Center: Phone: +420-541-162-113 Fax: +420-541-162-104
Denmark – Glostrup Phone: +45-43-48-04-00 Fax: +45-43-44-14-14
Egypt – Cairo Phone: +202-419-2334 Fax: +202-417-7647
Estonia – Tartu Phone: +372-5138-274 Fax: +372-7400-779
Finland – Helsinki Phone: +358-95-12-34-20 Fax: +358-95-12-34-250
Lithuania and Latvia
France - Cergy-Pontoise Cedex Phone: +33-1-3420-8888 Fax: +33-1-3420-8600 Product Information Center: Phone: +33-1-3420-8686 Fax: +33-1-3420-8623
Lithuania – Vilnius Phone: +370-5-213-1402 Fax: +370-5-213-1403 Product Information Center: Phone: +370-5-211-3016 Fax: +370-5-213-1403
– France Export Divisions Cergy-Pontoise Cedex Phone: +33-1-3420-8804 Fax: +33-1-3420-8699
Netherlands – ’s-Hertogenbosch Phone: +31-73-6246-246 Fax: +31-73-6212-365 Product Information Center: Phone: +31-73-6246-999 Fax: +31-73-6246-998
Germany – Bensheim Phone: +49-6251-133-0 Fax: +49-6251-133-1600 Product Information Center: Phone: +49-6251-133-1999 Fax: +49-6251-133-1988
Norway – Nesbru Phone: +47-66-77-88-50 Fax: +47-66-77-88-55
Greece – Athens Phone: +30-210-9370396/397 Fax: +30-210-9370-655
Poland – Warsaw Phone: +48-22-4576-700 Fax: +48-22-4576-720 Product Information Center: Phone: +48-22-4576-704 Fax: +48-22-4576-720
Hungary – Budapest Phone: +36-1-289-1000 Fax: +36-1-289-1010 Product Information Center: Phone: +36-1-289-1016 Fax: +36-1-289-1017
Romania – Bucharest Phone: +40-21-311-3479/3596 Fax: +40-21-312-0574 Russia – Moscow Phone: +7-495-790-7902 Fax: +7-495-721-1893 Product Information Center: Phone: +7-495-790-7902-404 Fax: +7-495-790-7902-401
Ireland – Dublin Phone: +353-1-866-5612 Fax: +353-1-866-5714
Israel – Petach-Tikva Phone: +972-3-929-0999 Fax: +972-3-919-1088
Russia – St. Petersburg Italy – Collegno (Torino) Phone: +7-812-718-8192 Phone: +39-011-4012-111 Fax: +7-812-718-8193 Fax: +39-011-4031-116 Product Information Center: Phone: +39-011-4012-632 Fax: +39-011-40-287-632
Slovenia – Ljubljana Phone: +386-1561-3270 Fax: +386-1561-3240
South Africa – Port Elizabeth Phone: +27-41-503-4500 Fax: +27-41-581-0440
Spain – Barcelona Phone: +34-93-291-0330 Fax: +34-93-201-7879
Sweden – Upplands Väsby Phone: +46-8-50-72-50-00 Fax: +46-8-50-72-50-01
Switzerland – Steinach Phone: +41-71-447-0447 Fax: +41-71-447-0444
Turkey – Istanbul Phone: +90-212-281-8181/2/3 +90-212-2825130/5430 Fax: +90-212-281-8184
Ukraine – Kiev
Phone: +380-44-206-2265 Fax: +380-44-206-2264 Product Information Center: Phone: +380-44-206-2265 Fax: +380-44-206-2264
– United Kingdom Stanmore, Middlesex Phone: +44-8706-080208 Fax: +44-208-954-6234 Product Information Center: Freephone (UK only): +0800-267-666 Phone: +44-8706-080208
Fax: +44-208-420-8095
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to **te.com/help corcom.com**
## **te.com**
## **corcom.com**
- © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company. All Rights Reserved.
1654001 CIS JG 06/2011
Corcom, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks. Other logos, product and/or company names might be trademarks of their respective owners.
-
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →