Image not available
Illustrative purposes only
15DYS851-120416G-K
AC/DC Power Supply, ITE & Medical, 1 Output, 49.5 W, 12 V, 4.16 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: IDEAL POWER
- Product type: AC / DC External Plug In Adaptor Power Supplies
- SVHC: No SVHC (04-Feb-2026)
- Plug Type: AU, EU, NZ, UK, US
- Product Range: 15DYS851-xxxyyyG-K Series
- No. of Outputs: 1 Output
- Output Connector: Barrel Plug Center Positive 2.1mm x 5.5mm
- Output Power Max: 49.5W
- Input Voltage VAC: 100V AC to 240V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 4.16A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE & Medical
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 15.62 € |
| Current stock | 25+ |
| Lead time | 30 days |
**15DYS851-xxxyyyG-K Interchangeable Series Up to 50 Watt** ## Features - Universal input 100-240VAC - Interchangeable Power Supply - Approved to UKCA, CE, cULus, TUV, FCC, (C-Tick), RoHS, REACH - EN/IEC/ES 60601-1 Safety Approved - Meets Efficiency Level VI - EMC Class B Certified - Single Output 12-48V DC - OVP, OCP, OTP & Short Circuit Ideal Power's 15DYS851-xxxyyyG-K 50W AC/DC External Adapter Interchangeable Power Supply (PSU) Series are certified to UKCA, CE, cULus, TUV, FCC, (C-Tick), RoHS, REACH & EN 60601-1/IEC 60601-1/ES 60601-1 Standards and comply with (EU) 2019/1782, Level VI Efficiency Regulations. These are primarily used in Medical, ITE, Audio & Video Industries and customised solutions are available upon request. |Models|||| |---|---|---|---| |Model Number|Output Voltage|Output Current|Output Power| ||V DC|A|W| |15DYS851-120416G-K|12|4.16|49.5| |15DYS851-190265G-K|19|2.65|50.4| |15DYS851-240210G-K|24|2.10|50.4| |15DYS851-480105G-K|48|1.05|50.4| |Input Data||||||| |---|---|---|---|---|---|---| ||Min|Typical|Max|Units||Notes| |Input Voltage|90|--|264|V AC|100-240VAC +/- 10%|| |Input Frequency|47|--|63|Hz|50-60Hz +/- 5%|| |Input Current|--|--|1.3|A||| |Inrush Current|--|--|60|A|At cold start, 100 / 240V AC|At cold start, 100 / 240V AC| |Leakage Current|--|--|0.25|mA||| ## Output Data ||Min|Typical|Max|Units|Notes| |---|---|---|---|---|---| |Output Voltage|--|5|--|%|| |Ripple & Noise|150|--|240|mVp-p|Model dependant| |Over Current Protection|||||Over Current Point Limited >2.16A| |Short Circuit Protection|||||Continuous short circuit proof.| ||||||Will recover if fault condition is removed| |Over Voltage Protection|||||Will recover if fault condition is removed| ## Ideal Power Limited 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England, EX32 7NZ. www.idealpower.co.uk | +44 (0) 845 260 3400 Page 1 of 5 **15DYS851-xxxyyyG-K Interchangeable Series** **Up to 50 Watt** ## Environmental Data ||Min|Typical|Max|Units|Notes| |---|---|---|---|---|---| |Operating Temperature|0||+40|ºC|| |Storage Temperature|-20||+80|ºC|| |Operating Humidity|10||90|ºC|Operating 10% to 90%| |Storage Humidity|5||95|ºC|Storage 5% to 95%| ## Other Information |MTBF|50,000hrs At 25°C, Full load, and nominal| |---|---| |Isolation|Primary to Secondary: 4242VDC/5mAMax (3 seconds)| |Dimensions|Refer to mechanical drawings| ## EMC Emissions (2014/30/EU) ||Standard|Test Level|Criteria||Notes| |---|---|---|---|---|---| |Conducted|EN 55032|Pass|B|EMC Directive 2014/30/EU|| |Radiated|EN 55032|Pass|B||| |Harmonic Standard|EN 61000-3-2||Class D|P.F. shall >0.95 @100Vac input and >0.9|P.F. shall >0.95 @100Vac input and >0.9| |||||@240Vac input|ut| ## EMI/EMS Immunity (2014/30/EU) ||Standard|Test Level|Criteria|Notes| |---|---|---|---|---| |EMS<br>EMS<br>ESD<br>RS|IEC/EN 60601-1-2<br>EN 55035<br>IEC 61000-4-2<br>IEC 61000-4-3||B|Contact: +/- 4KV; Air: +/- 8KV<br>Frequency: 80-1000MHz;<br>Field Strength: 3V/M ' 80% AM(1KHz)| |EFT|IEC 61000-4-4||A/B|0.5/1.0KV on input ACpowerports| |Surge|IEC 61000-4-5||A|Line to Line: +/- 1KV (peak);<br>Line to F.G: +/- 2KV(peak)| ## Safety Approvals Safety Standards RoHS/REACH RoHS Directive (EU) 2015/863 & REACH (205 SVHC) CE LVD Directive 2014/35/EU Yes (UK/European) cULus Yes TUV Yes RCM & C-Tick Yes ## Ideal Power Limited 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England, EX32 7NZ. www.idealpower.co.uk | +44 (0) 845 260 3400 Page 2 of 5 **15DYS851-xxxyyyG-K Interchangeable Series Up to 50 Watt** Mechanical Drawing - | Ideal Power Limited 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England, EX32 7NZ. www.idealpower.co.uk | +44 (0) 845 260 3400 Page 3 of 5 **15DYS851-xxxyyyG-K Interchangeable Series Up to 50 Watt** Mechanical Drawing ## Ideal Power Limited 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England, EX32 7NZ. www.idealpower.co.uk | +44 (0) 845 260 3400 Page 4 of 5 **15DYS851-xxxyyyG-K Interchangeable Series Up to 50 Watt** Mechanical Drawing |Model Number|Output Cable| |---|---| |15DYS851-120416G-K|1.55m UL1185 18AWG| |15DYS851-190265G-K|1.55m UL1185 22AWG| |15DYS851-240210G-K|1.55m UL1185 22AWG| |15DYS851-480105G-K|1.55m UL1185 22AWG| ## Ideal Power Limited 14 Larks Way, Tree Beech Enterprise Park, Gunn, Barnstaple, Devon, England, EX32 7NZ. www.idealpower.co.uk | +44 (0) 845 260 3400 Page 5 of 5
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.