Image not available
Illustrative purposes only
1558737-8
Power Relay, 4PST-NO, DPST-NC, 24 VDC, 8 A, SR6 Series, Through Hole, Non Latching
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TE CONNECTIVITY - SCHRACK
- Product type: Power Relays
- SVHC: No SVHC (21-Jan-2025)
- Coil Type: Non Latching
- Coil Voltage: 24VDC
- Product Range: SR6 Series
- Relay Mounting: Through Hole
- Coil Resistance: 822ohm
- Contact Current: 8A
- Relay Terminals: PC Pin
- Contact Material: Silver Tin Oxide
- Contact Voltage VAC: 277V
- Contact Voltage VDC: -
- Contact Configuration: 4PST-NO, DPST-NC
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 16.29 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **SCHRACK FORCE GUIDED RELAYS SR6 NEXT GENERATION (SR6NG)** GENERAL PURPOSE RELAYS FORCE GUIDED RELAYS ## **INTRODUCTION** TE Connectivity (TE)’s SR6nG is a fully compatible successor of TE’s force guided relay series SR6A/B/C/V/D/M. With its force guided contacts the state of a contact can be monitored with a diagnostic coverage of 99% (IEC 61508-2) which makes the SR6nG ideal to design safety circuits. The Minimum contact load of 5V / 1mA allows direct monitoring through controller input. A more sensitive monostable magnetic coil system reduces heat generation. The relay height of 15.7mm fits best in 22.5mm DIN rail housings. ## FEATURES - Monostable relay with 6 (4) force guided contacts acc. to IEC 61810-3 - Circuits of up to 400V can be connected. Contacts can switch up to 8A or 2200VA. - Creepage and clearance distances allow reinforced isolation (IEC EN 62477) not just between coil and contacts but also between all contacts. - 6 pole version with 3 different contact sets (3NO/3NC; 4NO/2NC; 5NO/1NC) ## APPLICATIONS - Safety Relay modules, - Safety Controllers, PLC’s - Machines, Presses, Robots, - Emergency shut-off, Light barriers - Elevator and escalator safety control - • Railway Level crossings, Signaling ## APPROVALS - VDE CERT. NO. 40055844 - Sensitive coil of 700mW allows use at 85°C under IEC 61810 conditions - Special 4 pole version offers >15mm isolation between contacts and just 550mW coil power - TUV 968/FSP 2469.00/22 - UL E214025 VOL.9 SEC.6 - CCC 2022000303000046 **==> picture [67 x 15] intentionally omitted <==** **----- Start of picture text -----**<br> Z T rovpgpint BBproved<br>**----- End of picture text -----**<br> **SR6 NEXT GENERATION** FORCE GUIDED RELAYS ## **COIL DATA** ## **CONTACT DATA @ 25°C** |**CONTACT DATA @ 25°C**|| |---|---| |Contact arrangement|3 form A(NO) + 3 form B(NC)<br>4 form A(NO) + 2 form B(NC)<br>5 form A(NO) + 1 form B(NC)<br>2 form A(NO) + 2 form B(NC)<br>3 form A(NO) + 1 form B(NC)| |Rated voltage|277 VAC| |Max. switching voltage|400 VAC| |Rated current|8A| |Total continuous current<br>ITH2 = I21+I2<br>2*12<br>3… I2<br>N|131A2| |Max. Breaking capacity AC|2200VA| |Max. Breaking capacity DC|see DC Load breaking diagram| |Contact material|AgSnO2| |Contact style|Single contact, Force guided<br>type A according to EN61810-3| |Min. recommended<br>contact load (reference)|5VDC, 1mA| |Initial contact resistance|≤100mΩat 1A, 24VDC<br>≤20Ωat 10mA, 5VDC| |Frequency of operation,<br>with/without load|6/150min-1| |**COIL DATA**|| |---|---| |Coil voltage range|5 to 110VDC| |Coil power 6-pole relays<br>SR6-33x-Lxxx-xx;<br>SR6-42x-Lxxx-xx;<br>SR6-51x-Lxxx-xx|700mW| |Coil power 4-pole relays<br>SR6-22x-Uxxx-xx;<br>SR6-31x-Uxxx-xx;|550mW| |Operative range, IEC 61810|2| |Coil insulation system<br>according UL|Class F| **==> picture [185 x 157] intentionally omitted <==** **----- Start of picture text -----**<br> Max. DC load breaking capacity<br>1000<br>2xNO<br>1xNO<br>Recommended Area<br>100<br>10<br>0.1 1 10<br>DC current [A]<br>DC voltage [V]<br>**----- End of picture text -----**<br> ## **CONTACT RATINGS FOR SR6-II NEXT GEN** **==> picture [488 x 224] intentionally omitted <==** **----- Start of picture text -----**<br> 10<br>Load Cycles<br>0.1 1 10<br>DC current [A]<br>IEC61810-1<br>on 1 form A<br>(NO) contact 8A, 250VAC resistive, 85°C 100x10 [3]<br>1.6 Coil operating range DC<br>IEC60947-5-1 Maximum operating voltage UMax<br>on 1 form A 1.4<br>AC15 - 250V/5A<br>(NO) contact<br>1.2<br>on 1 form A<br>DC13 - 24V/6A<br>(NO) contact Recommended<br>1 Urtd voltage range<br>UL61810<br>0.8<br>8A, 277VAC, general<br>on 1 form A purpose, 85°C 0.6<br>-40 -20 0 20 40 60 80 100<br>(NO) contact B300 Ambient temperature [°C]<br>R300<br>)rtd<br>Coil voltage (U/U<br>**----- End of picture text -----**<br> INDUSTRIAL / **SR6 NEXT GENERATION** 2 FORCE GUIDED RELAYS ## **SR6 NEXT GENERATION** ## **LOW SENSITIVE L COIL VERSION (700mW), DC COIL 6-POLE RELAYS** **==> picture [257 x 54] intentionally omitted <==** **----- Start of picture text -----**<br> Rated Operate Release Coil<br>Coil Rated coil<br>voltage voltage voltage resistance<br>Code power mW<br>VDC VDC VDC Ω ± 10%<br>**----- End of picture text -----**<br> |**Coil**<br>**Code**|**Rated**<br>**voltage**<br>**VDC**|**Operate**<br>**voltage**<br>**VDC**|**Release**<br>**voltage**<br>**VDC**|**Coil**<br>**resistance**<br>Ω±**10%**|**Rated coil**<br>**power mW**| |---|---|---|---|---|---| ||||||| |L005|5|3.5|0.5|26|700| |L006|6|4.2|0.6|51|700| |L009|9|6.3|0.9|115|700| |L012|12|8.4|1.2|205|700| |L015|15|10.5|1.5|321|700| |L018|18|12.6|1.8|462|700| |L021|21|14.7|2.1|630|700| |L024|24|16.8|2.4|822|700| |L030|30|21|3|1285|700| |L036|36|25.2|3.6|1851|700| |L040|40|28|4|2285|700| |L048|48|33.6|4.8|3291|700| |L060|60|42|6|5142|700| |L085|85|59.5|8.5|10321|700| |L110|110|77|11|17286|700| **ULTRA LOW SENSITIVE U COIL VERSION (550mW), DC COIL 4-POLE RELAYS** **==> picture [257 x 54] intentionally omitted <==** **----- Start of picture text -----**<br> Rated Operate Release Coil<br>Coil Rated coil<br>voltage voltage voltage resistance<br>Code power mW<br>VDC VDC VDC Ω ± 10%<br>**----- End of picture text -----**<br> |**Coil**<br>**Code**|**Rated**<br>**voltage**<br>**VDC**|**Operate**<br>**voltage**<br>**VDC**|**Release**<br>**voltage**<br>**VDC**|**Coil**<br>**resistance**<br>Ω±**10%**|**Rated coil**<br>**power mW**| |---|---|---|---|---|---| ||||||| |U005|5|3.5|0.5|45|550| |U006|6|4.2|0.6|65|550| |U009|9|6.3|0.9|147|550| |U012|12|8.4|1.2|262|550| |U015|15|10.5|1.5|409|550| |U018|18|12.6|1.8|589|550| |U021|21|14.7|2.1|802|550| |U024|24|16.8|2.4|1047|550| |U030|30|21|3|1636|550| |U036|36|25.2|3.6|2356|550| |U040|40|28|4|2909|550| |U048|48|33.6|4.8|4189|550| |U060|60|42|6|6546|550| |U085|85|59.5|8.5|13136|550| |U110|110|77|11|22000|550| All figures are given for coil without pre-energization, at ambient temperature +23°C. **==> picture [164 x 318] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristically electrical endurance acc.<br>IEC60947-5-1 AC-15 Ue=250VAC 23°C<br>1000000<br>100000<br>10000<br>0 1 2 3 4 5<br>Rated current [A]<br>Characteristically electrical endurance acc.<br>IEC60947-5-1 DC-1 Ue=24VDC<br>10000000<br>1000000<br>100000<br>10000<br>0 1 2 3 4 5 6 7 8<br>Rated current [A]<br>Cycles<br>Cycles<br>**----- End of picture text -----**<br> **==> picture [155 x 320] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristically electrical endurance acc.<br>IEC60947-5-1 DC-13 Ue=24VDC 23°C<br>10000000<br>1000000<br>100000<br>10000<br>0 1 2 3 4 5<br>Rated current [A]<br>Characteristically electrical endurance acc.<br>IEC60947-5-1 AC-1 Ue=250VAC 85°C<br>10000000<br>1000000<br>100000<br>10000<br>0 1 2 3 4 5 6 7 8<br>Rated current [A]<br>Cycles<br>Cycles<br>**----- End of picture text -----**<br> INDUSTRIAL / **SR6 NEXT GENERATION** 3 **SR6 NEXT GENERATION** FORCE GUIDED RELAYS ## **INSULATION DATA** ## **OTHER DATA** |Initial dielectric strength|Initial dielectric strength|Initial dielectric strength||||||||||EU RoHS/ELV,|| |---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||||||||||||China RoHS,|| ||between open contacts||1500Vrms|||||||||REACH, Halogen|| ||between contact and coil<br>between adjacent contacts||4000Vrms<br>3000Vrms|||||Material compliance||||content refer to the<br>Product Compliance<br>Support Center at|<br>| ||4-pole types:|||||||||||www.te.com/|| |||between adjacent contacts<br>longitudinal direction|4000Vrms|||||Ambient temperature||||customersupport/<br>rohssupportcenter<br>-40 to 85°C|| ||||||||||||||| |Initial surge withstand voltage||||||||Category of environmental protection|||||| ||between contact and coil||6000Vrms||||||IEC 61810|||RTIII - wash tight|| ||||||||||||||| |Clearance/creepage||||||||Weight||||approx. 29.5g|| ||||||||||||||| ||between open contacts||microdisconnections|||||Vibration resistance (functional) 30 - 500Hz|||||| ||between contact and coil||≥5.56mm||||||IEC 60068-2-6 (half sine) NO closing|||min. 10g, 10 s|| ||between adjacent contacts||≥5.56mm||||||IEC 60068-2-6 (half sine) NO opening|||min. 20g, 10 s|| ||4-pole types:||||||||IEC 60068-2-6 (half sine) NC opening|||min. 2g, 10 s|| ||||||||||||||| |||between adjacent contacts|≥15mm||||||IEC 60068-2-6 (half sine) NC closing|||min. 3g, 10 s|| |||longitudinal direction||||||Shock resistance (functional)|||||| ||||||||||||||| |Insulation to IEC EN 62477 (former EN 50178), type of insulation|||||||||IEC 60068-2-27 (half sine) NO|||min. 20g, 11ms|| ||between contact and coil||reinforced||||||IEC 60068-2-27 (half sine) NC|||min. 2g, 11ms|| ||between adjacent contacts||reinforced|||||Shock resistance (destructive)||||min. 100g, 11ms|| |||||||||Terminal type||||PCB-THT|| |||||||||Resistance to soldering heat THT|||||| ||||||||||IEC 60068-2-20||260°C/5s||| ||||||||||||||| |||||||||Packaging/unit||||tube/10 pcs.|| ## **OUTLINE DIMENSIONS** **==> picture [512 x 157] intentionally omitted <==** **----- Start of picture text -----**<br> 55 16.5<br>15.7<br>3.3<br>**----- End of picture text -----**<br> INDUSTRIAL / **SR6 NEXT GENERATION** 4 **SR6 NEXT GENERATION** FORCE GUIDED RELAYS ## **OUTLINE DIMENSIONS** **==> picture [498 x 169] intentionally omitted <==** **----- Start of picture text -----**<br> 3of rm A + 3of rm B ,3 NO + 3N Cv eoisrn s 4of rm A + 2of rm B ,4 NO + 2N Cv eoisrns 5of rm A + 1of rm B ,5 NO + 1N Cv eoisrns<br>SR6 SR6 SR6<br>S0368-CA S0368-CA S0368-CE<br>S0368-CC S0368-CB S0368-CD<br>**----- End of picture text -----**<br> **==> picture [494 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> 4 form A + 2 form B, 4 NO + 2 NC versions SR6 2 form A + 2 form B, 2 NO + 2 NC versions 3 form A + 1 form B, 3 NO + 1 NC contacts<br>18<br>S0368-CU 18 S0368-CI 17 S0368-CK<br>S0368-CL<br>S0368-CJ<br>S0368-CV<br>**----- End of picture text -----**<br> The design of the SR6 Next Gen with crossed pin layout allows clearance/creepage of 5.56 mm on the PCB. INDUSTRIAL / **SR6 NEXT GENERATION** 5 **SR6 NEXT GENERATION** FORCE GUIDED RELAYS ## **PRODUCT CODE STRUCTURE** |**PRODUCT CODE STRUCTURE**|**PRODUCT CODE STRUCTURE**||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||**Part Number**<br>**SR 6 -4 2 3 -L 005 -0 0 0 ####**|||||||||||| |**Type**<br>**SR6**<br>Relay with force guided contacts<br>**Version**<br>**6**<br>6 pole<br>**Number of NO contact confgurations**<br>**5**<br>5 form A, NO sets<br>**4**<br>4 form A, NO sets<br>**3**<br>3 form A, NO sets<br>**2**<br>2 form A, NO sets (4-pole types<br>only)<br>**Number of NC contact confgurations**<br>**1**<br>1 form B, NC sets<br>**2**<br>2 form B, NC sets<br>**3**<br>3 form B, NC sets<br>**Contact Material**<br>**3**<br>AgSnO2<br>**6**<br>AgSnO2+ Au fush<br>**Coil version**<br>**L**<br>DC 700mW coil power (6-pole<br>types only)<br>**U**<br>DC 550mW coil power (4-pole<br>types only)||||**`**<br>**`**<br>**`**<br>**`**|**`**<br>**`**<br>**`**<br>**`**|**`**<br>**`**<br>**`**|**`**<br>**`**|**`**||**Additional manufacturer indications**|||| |||||||||||**####**|||May be followed by up to 4<br>numbers and/or letters only<br>for manufacturer internal<br>identifcation| |||||||||||**Mechanical features (Pin length)**|||| |||||||||||**0**||Standard (3,3mm)|| |||||||||||**1**||Short pin (2,5mm)|| |||||||||||**Electrical Features (Terminal allignment)**|||| |||||||||||**O**||Standard pin layout|| |||||||||||**V**||Crossed pin layout|| |||||||||||**Category of protection**|||| |||||||||||**0**||RTIII Wash tight|| |||||||||||**Coil**|||| |||||||||||Coil voltage code: please refer to coil<br>versions table (e.g. 005=5VDC)|||| ||||||||||||||| ||||||||||||||| |**L**|DC 700mW coil power (6-pole<br>types only)||||||||||||| ||||||||||||||| |**U**|DC 550mW coil power (4-pole<br>types only)||||||||||||| INDUSTRIAL / **SR6 NEXT GENERATION** 6 **SR6 NEXT GENERATION** FORCE GUIDED RELAYS ## **PRODUCT INFORMATION** **==> picture [526 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> Product code Type Contact arrangement Contact material Coil Coil power Part number<br>**----- End of picture text -----**<br> |**Product code**|**Type**|**Contact arrangement**|**Contact material**|**Coil**|**Coil power**|**Part number**| |---|---|---|---|---|---|---| |||||||| |SR6-333-L005-00|6-pole<br>relay with<br>force guided<br>contacts|3 form A + 3 form B,<br>3NO + 3NC contacts|AgSnO2|5VDC|700mW|1558736-1| |SR6-333-L012-00||||12VDC||1558736-4| |SR6-333-L021-00||||21VDC||1558736-7| |SR6-333-L024-00||||24VDC||1558736-8| |SR6-333-L048-00||||48VDC||1-1558736-2| |SR6-333-L060-00||||60VDC||1-1558736-3| |SR6-333-L110-00||||110VDC||1-1558736-5| |SR6-336-L005-00|||AgSnO2 + Au|5VDC||2-1558736-1| |SR6-336-L012-00||||12VDC||2-1558736-4| |SR6-336-L018-00||||18VDC||2-1558736-6| |SR6-336-L021-00||||21VDC||2-1558736-7| |SR6-336-L024-00||||24VDC||2-1558736-8| |SR6-336-L110-00||||110VDC||3-1558736-5| |SR6-423-L005-00||4 form A + 2 form B,<br>4NO + 2NC contacts|AgSnO2|5VDC||1558737-1| |SR6-423-L006-00||||6VDC||1558737-2| |SR6-423-L012-00||||12VDC||1558737-4| |SR6-423-L018-00||||18VDC||1558737-6| |SR6-423-L021-00||||21VDC||1558737-7| |SR6-423-L024-00||||24VDC||1558737-8| |SR6-423-L040-00||||40VDC||1-1558737-1| |SR6-423-L048-00||||48VDC||1-1558737-2| |SR6-423-L060-00||||60VDC||1-1558737-3| |SR6-423-L085-00||||85VDC||1-1558737-4| |SR6-423-L110-00||||110VDC||1-1558737-5| |SR6-426-L012-00|||AgSnO2 + Au|12VDC||2-1558737-4| |SR6-426-L015-00||||15VDC||2-1558737-5| |SR6-426-L018-00||||18VDC||2-1558737-6| |SR6-426-L021-00||||21VDC||2-1558737-7| |SR6-426-L024-00||||24VDC||2-1558737-8| |SR6-513-L012-00||5 form A + 1 form B,<br>5NO + 1NC<br>contacts|AgSnO2|12VDC||1558738-4| |SR6-513-L018-00||||18VDC||1558738-6| |SR6-513-L024-00||||24VDC||1558738-8| |SR6-513-L048-00||||48VDC||1-1558738-2| |SR6-513-L060-00||||60VDC||1-1558738-3| |SR6-513-L110-00||||110VDC||1-1558738-5| |SR6-516-L012-00|||AgSnO2 + Au|12VDC||2-1558738-4| |SR6-516-L024-00||||24VDC||2-1558738-8| Note. This list represents the most common types and does not show all variants covered by this datasheet. Other types on request. INDUSTRIAL / **SR6 NEXT GENERATION** 7 ## **PRODUCT INFORMATION CONTINUED..** **==> picture [526 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Product code Type Contact arrangement Contact material Coil Coil power Part number<br>**----- End of picture text -----**<br> |**Product code**|**Type**|**Contact arrangement**|**Contact material**|**Coil**|**Coil power**|**Part number**| |---|---|---|---|---|---|---| |||||||| |SR6-426-L012-0V||4 form A + 2 form B,<br>4NO + 2NC contacts<br>(crossed pin layout|AgSnO2 + Au|12VDC|700mW|2-1558739-4| |SR6-426-L015-0V||||15VDC||2-1558739-5| |SR6-426-L018-0V||||18VDC||2-1558739-6| |SR6-426-L021-0V||||21VDC||2-1558739-7| |SR6-426-L024-0V||||24VDC||2-1558739-8| |SR6-426-L040-0V||||40VDC||3-1558739-1| |SR6-426-L110-0V||||110VDC||3-1558739-5| |SR6-223-U012-00|4-pole<br>relay with<br>force guided<br>contacts|2 form A + 2 form B,<br>2NO + 2NC contacts|AgSnO2|12VDC|550mW|1558740-4| |SR6-223-U018-00||||18VDC||1558740-6| |SR6-223-U021-00||||21VDC||1558740-7| |SR6-223-U024-00||||24VDC||1558740-8| |SR6-223-U040-00||||40VDC||1-1558740-1| |SR6-223-U110-00||||110VDC||1-1558740-5| |SR6-313-U006-00||3 form A + 1 form B,<br>3NO + 1NC contacts||6VDC||1558741-2| |SR6-313-U012-00||||12VDC||1558741-4| |SR6-313-U018-00||||18VDC||1558741-6| |SR6-313-U021-00||||21VDC||1558741-7| |SR6-313-U024-00||||24VDC||1558741-8| |SR6-313-U048-00||||48VDC||1-1558741-2| |SR6-313-U110-00||||110VDC||1-1558741-5| Note. This list represents the most common types and does not show all variants covered by this datasheet. Other types on request. ## **Notes:** 1. Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. 2. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions. 3. Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. ## **te.com** ## ©2023 TE Connectivity. All Rights Reserved. TE Connectivity, TE connectivity (logo) and Every Connection Counts are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. 03/23 ED INDUSTRIAL / **SR6 NEXT GENERATION**
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →