- Manufacturer: FINDER
- Product type: Analogue Timers - DIN Rail
- Product Range:14 Series; Timer Functions:Multifunction; Time Min:30s; Time Max:20min; No. of Timing Ranges:-; Timer Output:1 Changeover Relay; Supply Voltage Max:230VAC; Current R
- SVHC: No SVHC (04-Feb-2026)
- Time Max: 20min
- Time Min: 30s
- Timer Output: 1 Changeover Relay
- Product Range: 14 Series
- Timer Functions: Multifunction
- Current Rating Nom: 500mA
- Supply Voltage Max: 230VAC
- No. of Timing Ranges: -
- Connection / Termination: Screw Terminals
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 39.83 € |
| Current stock | 10+ |
| Lead time | 30 days |
**14 SERIES** **I** - **Multi-function electronic staircase timers 1 NO 16 A 17.5 mm wide Type 14.01** -8 functions -Switch-off “early warning” options - **Type 14.71** -3 functions - • Time setting from 30 seconds to 20 minutes • “Zero crossing” load switching • “Switch-off early warning” - model 14.01 • Suitable for 3 or 4 wire systems, with automatic recognition - • Compatible with movement detectors (18 series) • LED status indicators • Cadmium free contact material • Can be used with illuminated push - buttons • “Blade + cross” - both flat blade and cross head screw drivers can be used to adjust the function selector, the timing trimmer, and to disengage the 35 mm rail mounting clip - • 35 mm rail (EN 60715) mount • European Patent |**Multi-function electronic staircase timers**<br>**1 NO 16 A 17.5 mm wide**<br>**Type 14.01**<br>-8 functions 8 functions<br>-Switch-off “early warning” options Switch-off “early warning” options<br>**Type 14.71**<br>-3 functions 3 functions<br>• Time setting from 30 seconds to 20 minutesTime setting from 30 seconds to 20 minutes<br>• “Zero crossing” load switching“Zero crossing” load switching<br>• “Switch-off early warning” - model 14.01“Switch-off early warning” - model 14.01<br>• Suitable for 3 or 4 wire systems, with automaticSuitable for 3 or 4 wire systems, with automatic<br>recognition<br>• Compatible with movement detectors (18 series)Compatible with movement detectors (18 series)<br>• LED status indicatorsLED status indicators<br>• Cadmium free contact materialCadmium free contact material<br>• Can be used with illuminated push - buttonsCan be used with illuminated push - buttons<br>• “Blade + cross” - both flat blade and cross“Blade + cross” - both flat blade and cross<br>head screw drivers can be used to adjust the<br>function selector, the timing trimmer, and to<br>disengage the 35 mm rail mounting clip<br>• 35 mm rail (EN 60715) mount35 mm rail (EN 60715) mount<br>• European PatentEuropean Patent<br>14.01/71<br>Screw terminal<br>For outline drawing see page 8<br>**Contact specification**<br>Contact configuration|**14.01**<br>•8 functions:<br>- Staircase timer<br>- Staircase timer +<br>maintenance function<br>- Staircase timer with early<br>warning<br>- Staircase timer with early<br>warning + maintenance<br>function<br>- Timing step relay<br>- Timing step relay with early<br>warning<br>- Step relay<br>- Light ON<br>1 NO (SPST-NO)<br>66<br>os|**14.01**<br>•8 functions:<br>- Staircase timer<br>- Staircase timer +<br>maintenance function<br>- Staircase timer with early<br>warning<br>- Staircase timer with early<br>warning + maintenance<br>function<br>- Timing step relay<br>- Timing step relay with early<br>warning<br>- Step relay<br>- Light ON<br>1 NO (SPST-NO)<br>66<br>os|**14.01**<br>•8 functions:<br>- Staircase timer<br>- Staircase timer +<br>maintenance function<br>- Staircase timer with early<br>warning<br>- Staircase timer with early<br>warning + maintenance<br>function<br>- Timing step relay<br>- Timing step relay with early<br>warning<br>- Step relay<br>- Light ON<br>1 NO (SPST-NO)<br>66<br>os|**14.71**<br>•3 functions:<br>- Staircase timer<br>- Staircase timer +<br>maintenance function<br>- Light ON<br>1 NO (SPST-NO)<br>66<br>“@ r| |---|---|---|---|---| |Rated current/Maximumpeak current<br>A|16/30 (120 A - 5 ms)<br>~~es~~|||16/30 (120 A - 5 ms)<br>~~es~~| |Rated voltage/<br>Maximum switchingvoltage<br>V AC|230/—|||230/—| |Rated load AC1<br>VA|3700<br>~~es~~|||3700<br>~~es~~| |Rated load AC15 (230 V AC)<br>VA|750<br>~~es~~|||750<br>~~es~~| |Nominal lamp rating:<br>230 V incandescent/halogen W<br>fluorescent tubes with<br>electronic ballast W<br>fluorescent tubes with<br>electromagnetic ballast W<br>CFL W<br>230 V LED W<br>LV halogen or LED with<br>electronic ballast W<br>LV halogen or LED with<br>electromagnetic ballast W|3000|||3000| ||1500|||1500| ||1000|||1000| ||600<br>~~es~~|||600<br>~~es~~| ||600<br>~~es~~<br>~~es~~|||600<br>~~es~~<br>~~es~~| ||600|||600| ||1500|||1500| |Minimum switchingload<br>mW (V/mA)|1000 (10/10)<br>~~ee~~|||1000(10/10)<br>~~ee~~| |Standard contact material<br>**Supply specification**<br>Nominal voltage (UN)<br>V AC (50/60 Hz)<br>V DC|AgSnO2<br>230<br>~~ee~~|||AgSnO2<br>230<br>~~ee~~| ||—<br>~~es~~|||—<br>~~es~~| |Ratedpower<br>VA (50 Hz)/W|3/1.2<br>~~es~~|||3/1.2<br>~~es~~| |Operating range<br>AC (50 Hz)<br>DC<br>**Technical data**<br>Electrical life at rated load in AC1<br>cycles|(0.8…1.1)UN<br>~~ee~~|||(0.8…1.1)UN<br>~~ee~~| ||—<br>100 · 103|||—<br>100 · 103| |Delaysetting<br>min|0.5…20<br>~~es~~|||0.5…20<br>~~es~~| |Max no. of illuminatedpush-button (≤1 mA)|30<br>~~es~~|||30<br>~~es~~| |Maximum impulse duration|continuous<br>~~ee~~|||continuous<br>~~ee~~| |Ambient temperature range<br>°C|–10…+60<br>~~ee~~|||–10…+60<br>~~ee~~| |Protection category|IP 20<br>~~pO~~|||IP 20<br>~~pO~~| |**Approvals**(according to type)|CeHH|HH|HH~~Se~~@|| **1** **14 SERIES** **Mono-function electronic staircase timers 1 NO 16 A 17.5 mm wide** ## **Type 14.81** -Staircase timer + maintenance function ## **Type 14.91** - -Signal ON pulse timer - Time setting from 30 seconds to 20 minutes - “Zero crossing” load switching - Wiring compatible with mechanical versions and with old type (low emission) illuminated pushbuttons - Suitable for 3 or 4 wire systems, via “pushbutton configuration” - 110…125 V AC supply version available (14.81) - Cadmium free contact material - Can be used with illuminated push - buttons - “Blade + cross” - both flat blade and cross head screw drivers can be used to adjust the function selector, the timing trimmer, and to disengage the 35 mm rail mounting clip - **14.81 14.91** - Mono-function: • Mono-function: -Staircase timer + -Signal ON pulse timer - Mono-function: - maintenance function • All 3 terminal on same side - All 4 terminal on same side - 35 mm rail (EN 60715) mount ## 14.81/91 Screw terminal For outline drawing see page 8 **I** - |For outline drawing see page 8|| |---|---| |**Contact specification**<br>Contact configuration|1 NO (SPST-NO)<br>1 NO (SPST-NO)| |Rated current/Maximum peak current<br>A|16/30 (120 A - 5 ms)<br>16/30 (120 A - 5 ms)<br>~~es~~| |Rated voltage/<br>Maximum switchingvoltage<br>V AC|230/—<br>230/—| |Rated load AC1<br>VA|3700<br>3700<br>~~ee~~| |Rated load AC15 (230 V AC)<br>VA|750<br>750<br>~~es~~| |Nominal lamp rating:<br>230 V incandescent/halogen W|3000<br>3000| |fluorescent tubes with<br>electronic ballast W|1500<br>1500| |fluorescent tubes with<br>electromagnetic ballast W<br>CFL W<br>230 V LED W<br>LV halogen or LED with<br>electronic ballast W|1000<br>1000<br>600<br>600<br>600<br>600<br>600<br>600<br>~~es~~<br>~~es~~| |LV halogen or LED with<br>electromagnetic ballast W|1500<br>1500| |Minimum switchingload<br>mW (V/mA)|1000 (10/10)<br>1000(10/10)<br>~~es~~| |Standard contact material<br>**Supply specification**<br>Nominal voltage (UN)<br>V AC (50/60 Hz)|AgSnO2<br>AgSnO2<br>110…125/230<br>230| |V DC|—<br>—<br>~~es~~| |Rated power<br>VA (50 Hz)/W<br>Operating range<br>AC (50 Hz)|3/1.2<br>3/1.2<br>(0.8…1.1)UN<br>(0.8…1.1)UN<br>~~ee~~<br>~~es~~| |DC<br>**Technical data**|—<br>—| |Electrical life at rated load in AC1<br>cycles|100 · 103<br>100 · 103| |Delaysetting<br>min|0.5…20<br>0.5…20<br>~~es~~| |Max no. of illuminated push-button (≤1 mA)|25<br>25<br>~~es~~| |Maximum impulse duration|continuous<br>continuous<br>~~ee~~| |Ambient temperature range<br>°C|–10…+60<br>–10…+60<br>~~es~~| |Protection category|IP 20<br>IP 20<br>~~es~~| |**Approvals**(according to type)|~~CHeOG~~<br>cemhe| **2** **14 SERIES** **I** ## **Ordering information** Example: 14 series multi-function timer, 1 NO (SPDT-NO) 16 A contact, supply rated at 230 V AC. **1 4 . 0 1 . 8 . 2 3 0 . 0 0 0 0 Series Supply voltage** 120 = 110…125 V AC (14.81 only) **Type** 230 = 230 V 0 = 35 mm rail (EN 60715) mount, 8 functions **Supply version** 7 = 35 mm rail (EN 60715) mount, 8 = AC (50/60 Hz) 3 functions 8 = 35 mm rail (EN 60715) mount mono-function, all terminals on same side 9 = 35 mm rail (EN 60715) mount, mono-function, 3 terminals ~~Te~~ **No. of poles** 1 = 1 NO 16 A contact ## **Technical data** |Dielectric strength between open contacts<br>V AC <br>**Other data**<br>Power lost to the environment<br>without contact current<br>W <br>with rated current<br>W|1000<br> 1.2|1000<br> 1.2| |---|---|---| ||2|| |Maximum cable length for push-button connection<br>m <br>Screw torque<br>Nm|200<br>0.8|| |Screw torque<br>Nm|0.8|| |Max. wire size<br>mm2 <br>AWG|solid cable|stranded cable| ||1 x 6 / 2 x 4|1 x 4 / 2 x 2.5| ||1 x 10 / 2 x 12|1 x 12 / 2 x 14| ## **Zero crossing switching** - **1 -** Lower inrush current protects and increases lamp life - **2 -** Lower inrush current reduces the possibility of contact welding - **3 -** The current at switch-off is also lower, reducing stress and wear on the contacts ## Note Using the type 14.91, the lamps are switched on directly by the push-button **Accessories** ~~_~~ **020.01 060.72** |**Adaptor for panel mounting,**17.5 mm wide<br>~~_~~|020.01| |---|---| |**Sheet of marker tags,**plastic, 72 tags, 6 x 12 mm|060.72| **Sheet of marker tags,** plastic, 72 tags, 6 x 12 mm **3** **14 SERIES** ## **Wiring diagrams** ## **Type 14.01** ## **14.71** Red LED indication: Continuous = relay ON Blinking = relay OFF **==> picture [172 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> L<br>N<br>3 wire connection<br>**----- End of picture text -----**<br> **==> picture [172 x 182] intentionally omitted <==** **----- Start of picture text -----**<br> L<br>N<br>4 wire connection<br>**----- End of picture text -----**<br> **Type 14.81** (push-button configuration procedure, as per the Installation manual) **I** **==> picture [512 x 198] intentionally omitted <==** **----- Start of picture text -----**<br> L<br>L<br>N<br>N<br>3 wire connection 4 wire connection<br>**----- End of picture text -----**<br> **Type 14.91** (the push-buttons must be rated for the load current) **==> picture [201 x 66] intentionally omitted <==** **----- Start of picture text -----**<br> L<br>N<br>**----- End of picture text -----**<br> **==> picture [148 x 99] intentionally omitted <==** **4** **14 SERIES** **I** **Wiring diagrams** - 14.01 or 14.71 without Staircase maintenance function, triggered by PIR movement detector (18 series). **==> picture [488 x 323] intentionally omitted <==** **----- Start of picture text -----**<br> 3 wire connection (with 18.21.8.230.0300 or 18.31.8.230.0300 only) 4 wire connection (with 18.21.8.230.0300 or 18.31.8.230.0300 only)<br>L L<br>N N<br>4 wire connection (with 18.01.8.230.0000 or 18.11.8.230.0000 only)<br>L<br>N<br>**----- End of picture text -----**<br> **5** **14 SERIES** ## **Functions** **Type 14.01** Functions selectable with front rotary selector **==> picture [196 x 72] intentionally omitted <==** **==> picture [13 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> BE<br>**----- End of picture text -----**<br> **==> picture [196 x 72] intentionally omitted <==** ## **(BE) Staircase timer** On initial impulse the output contact closes and timing starts for the pre-set duration; subsequent impulses during the timing period will extend the timing period by the full pre-set value. On expiry of the time delay, the output contact opens. **==> picture [194 x 58] intentionally omitted <==** ## **+** ## **(ME) Staircase timer + Staircase maintenance** In addition to the Staircase timer function (BE), an impulse of ≥ 5 seconds will close the output contact for 60 minutes, after which time the contact will open. Ideal for maintenance or cleaning activities. The 60 minute timing can be interrupted by a further impulse of ≥ 5 seconds, and the output contact then opens **==> picture [194 x 50] intentionally omitted <==** **==> picture [13 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> BP<br>**----- End of picture text -----**<br> **==> picture [194 x 50] intentionally omitted <==** ## **(BP) Staircase timer with early warning** On initial impulse the output contact closes and the timing starts for the pre-set duration. After the timing period, the output contact blinks off once; 10secs later the contact blinks off twice, and after a further 10secs the contact opens. During the pre-set and 20 second warning time, it is possible, by a further impulse, to extend the time by the full pre-set value. **==> picture [194 x 56] intentionally omitted <==** ## **+** ## **(MP) Staircase timer with early warning + Staircase maintenance** **I** **==> picture [194 x 101] intentionally omitted <==** In addition to the Staircase timer function (BP), an impulse of ≥ 5 seconds will close the output contact for 60 minutes, after which time the contact will open. Ideal for maintenance or cleaning activities. The 60 minute timing can be interrupted by a further impulse of ≥ 5 seconds, and the output contact then opens ## **(IT) Timing step relay** On initial impulse the output contact closes and timing starts for the pre-set duration; On expiry of the time delay, the output contact opens. During the timing period it is possible to immediately open the contact with a further impulse. ## **(IP) Timing step relay with early warning** On initial impulse the output contact closes and timing starts for the pre-set duration; After the timing period, the output contact blinks off once; 10 secs later the contact blinks off twice, and after a further 10 secs the contact opens. During the pre-set and 20 second warning time, it is possible to immediately open the output contact by a further impulse. ## **(RI) Step relay** After every impulse, the output contact changes state - alternately switching from open to closed and vice versa. ## **Light ON** With this function set - the output contact stays permanently closed. NOTE: The blinking within the Early Warning functions (BP and IP) could cause re-start problems for fluorescent lamps with electromagnetic chokes (both conventional and compact types); We consequently suggest not to use such lamps with these functions. **6** **14 SERIES** ## **Functions** **Type 14.71** Functions selectable with front selector ## **3-function front selector** **==> picture [511 x 64] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Staircase timer +|Staircase maintenance| |Light ON| |Staircase timer (compatible with 18 series movement detectors)| **----- End of picture text -----**<br> **==> picture [195 x 127] intentionally omitted <==** ## **Staircase timer** On initial impulse the output contact closes and timing starts for the pre-set duration; subsequent impulses during the timing period will extend the timing period by the full pre-set value. On expiry of the time delay, the output contact opens. ## **Staircase maintenance** An impulse of ≥ 5 seconds will close the output contact for 60 minutes, after which time the contact will open. Ideal for maintenance or cleaning activities. The 60’ timing can be interrupted by a further impulse of ≥ 5 seconds, the output contact opens. ## **Light ON** With this function set - the output contact stays permanently closed. ## **Type 14.81** **==> picture [195 x 129] intentionally omitted <==** ## **Staircase timer** On initial impulse the output contact closes and timing starts for the pre-set duration; subsequent impulses during the timing period will extend the timing period by the full pre-set value. On expiry of the time delay, the output contact opens. ## **“Staircase maintenance” function** An impulse of ≥ 5 seconds will close the output contact for 60 minutes, after which time the contact will open. Ideal for maintenance or cleaning activities. The 60’ timing can be interrupted by a further impulse of ≥ 5 seconds, which will re-establish the staircase timer function; so on expiry of the staircase time delay, the output contact opens. **I** ## **Type 14.91** **==> picture [194 x 44] intentionally omitted <==** ## **Signal ON pulse** On initial impulse the output contact closes, and remain so for the duration of the preset delay. On expiry of the time delay, the output contact opens. **7** **14 SERIES** ## **Outline drawings** **I** 14.01 Screw terminal **==> picture [194 x 149] intentionally omitted <==** **==> picture [44 x 15] intentionally omitted <==** **----- Start of picture text -----**<br> 14.81<br>Screw terminal<br>**----- End of picture text -----**<br> **==> picture [167 x 186] intentionally omitted <==** **==> picture [44 x 15] intentionally omitted <==** **----- Start of picture text -----**<br> 14.71<br>Screw terminal<br>**----- End of picture text -----**<br> **==> picture [193 x 163] intentionally omitted <==** **==> picture [44 x 15] intentionally omitted <==** **----- Start of picture text -----**<br> 14.91<br>Screw terminal<br>**----- End of picture text -----**<br> **==> picture [39 x 39] intentionally omitted <==** **==> picture [105 x 146] intentionally omitted <==** **8**
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →