131182300000
Power Relay, SPDT, 230 VAC, 12 A, 13 Series, DIN Rail, Panel
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: FINDER
- Product type: Power Relays
- Contact Configuration:SPDT; Coil Voltage:230VAC; Contact Current:12A; Product Range:13 Series; Relay Mounting:DIN Rail, Panel; Coil Type:-; Contact Voltage VAC:250V; Relay Termin
- SVHC: No SVHC (04-Feb-2026)
- Coil Type: -
- Coil Voltage: 230VAC
- Product Range: 13 Series
- Relay Mounting: DIN Rail, Panel
- Coil Resistance: -
- Contact Current: 12A
- Relay Terminals: Screw
- Contact Material: Silver Cadmium Oxide
- Contact Voltage VAC: 250V
- Contact Voltage VDC: -
- Contact Configuration: SPDT
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 49.66 € |
| Current stock | 10+ |
| Lead time | 30 days |
~~fi~~ nder SWITCH TO THE FUTURE Electronic step, call/reset y ® c and monostable relays GE @nnaer **W/C** Call and reset switches for bathrooms g& xox 4 ps Bathrooms lighting control Bedroom light control eL ~~es~~ eke iFY Lieew, — BS Vins3 eroet, Abode Ww | > rr Living room light control * @ J cm Y Office lighting Outerj : - : |Bi control **13 SЕRIES** FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products. **13 SERIES** **K** ## **13.81 - Electronic step relay - Rail mount - 1 Pole** **==> picture [139 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 13.81 13.91<br>**----- End of picture text -----**<br> ## **13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole** - Fixed time (10 minutes) timing function selectable (13.91) - Use with 3 or 4 wire connection, with automatic recognition by the relay - Control input can be continuously applied - Longer mechanical and electrical life, and much quieter than electromechanical step relays - “Zero crossing” load switching - Can be mounted behind blanking plates, as widely used in residential wiring systems such as; BTicino: Axolute, Matix, Living and Magic, Gewiss: GW24, Vimar: Plana and Idea … (13.91) - 35 mm rail (EN 60715) mount (13.81) - 1 NO (SPST-NO) - 35 mm rail (EN 60715) mount - 17.5 mm wide - 1 NO (SPST-NO) - Step relay and timing step relay (10 minutes) - For mounting within residential switch boxes - Cadmium free contact material ## 13.81/91 ## Screw terminals ||For outline drawing see page 12|| |---|---|---| ||**Contact specification**<br>Contact configuration|1 NO (SPST-NO)<br>1 NO (SPST-NO)| ||Rated current/Maximumpeak current<br>A<br>Rated voltage/<br>Maximum switchingvoltage<br>V AC|16/30 (120 - 5 ms)<br>10/20 (80 - 5 ms)<br>230/—<br>230/—<br>~~en~~| ||Rated load AC1<br>VA<br>Rated load AC15 (230 V AC)<br>VA<br>Nominal lamp rating:<br>230 V incandescent/halogen W|3700<br>2300<br>750<br>450<br>3000<br>1000<br>~~ee~~<br>~~ee~~| ||fluorescent tubes with<br>electronic ballast W|1500<br>500| ||fluorescent tubes with<br>electromechanical ballast W|1000<br>350| ||CFL W|600<br>300<br>~~en~~| ||230 V LED W|600<br>300<br>~~ee~~| ||LV halogen or LED with<br>electronic ballast W|600<br>300| ||LV halogen or LED with<br>electromechanical ballast W|1500<br>500| ||Minimum switchingload<br>mW (V/mA)<br>Standard contact material<br>**Supply specification**<br>Nominal voltage (UN)<br>V AC (50/60 Hz)|1000 (10/10)<br>1000 (10/10)<br>AgSnO2<br>AgSnO2<br>230<br>230<br>~~ee~~| ||V DC|—<br>—<br>~~ee~~| ||Ratedpower<br>V A (50 Hz)/W|3/1.2<br>2/1<br>~~ee~~| ||Operating range<br>AC (50 Hz)<br>DC<br>**Technical data**|(0.8…1.1)UN<br>(0.8…1.1)UN<br>—<br>—<br>~~es~~| ||Electrical life at rated load in AC1<br>cycles|100 · 103<br>100 · 103| |XI-2017, www.findernet.com|Maximum impulse duration<br>Dielectric strength between: open contacts V AC<br>supply- contacts V AC<br>Ambient temperature range<br>°C<br>Protection category<br>**Approvals**(according to type)|continuous<br>continuous<br>1000<br>1000<br>—<br>—<br>–10…+60<br>–10…+50<br>IP 20<br>IP 20<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~es~~<br>CE He @<br>C€ FAL~~©~~| **3** **13 SERIES** - **13.01 - Electronic step/monostable relay Rail mount - 1 Pole** ## **13.01** igh ## **13.61.0.024.0000 13.61.8.230.0000** | - **13.61 - Multifunction step/monostable relay with reset command - Rail mount 1 Pole** - Selectable Step or Monostable operation (13.01) - Multifunction (Step, Timing step, Monostable, Light ON) (13.61) - Reset feature, for centralized off command (13.61) - Set feature, for centralized on command (13.61.0.024) - Control input can be continuously applied - Longer mechanical and electrical life, and much quieter than electromechanical step relays - 12…24 V AC/DC and 110…240 V AC supply versions (13.61) - Suitable for SELV applications and available also for supply 12 and 24 V AC/DC (13.01) - “Zero-crossing” load switching (13.61) - 35 mm rail (EN 60715) mount - Cadmium free contact material ## 13.01/61 Screw terminals - 1 CO (SPDT) - Step or monostable relay - 35 mm rail (EN 60715) mount - 35 mm wide - 1 CO (SPDT) - Reset feature, for centralized off command - Set feature, for centralized on command - Multifunction: - step relay - timing step relay (30s…20min) - monostable relay - light on - 35 mm rail (EN 60715) mount - 1 NO (SPST-NO) - Reset feature, for centralized off command - Multifunction: - step relay - timing step relay (30s…20min) - monostable relay - light on - 35 mm rail (EN 60715) mount - 17.5 mm wide - 17.5 mm wide For outline drawing see page 12 ||**Contact specification**<br>Contact configuration|1 CO (SPDT)<br>1 CO<br>1 NO|| |---|---|---|---| ||Rated current/Maximumpeak current<br>A<br>Rated voltage/<br>Maximum switchingvoltage<br>V AC|16/30 (120 A - 5 ms)<br>16/30 (120 A - 5 ms)<br>16/30 (120 A - 5 ms)<br>250/400<br>250/400<br>250/400<br>~~es~~|| ||Rated load AC1<br>VA|4000<br>4000<br>4000<br>~~es~~|| ||Rated load AC15 (230 V AC)<br>VA|750<br>750<br>750<br>~~es~~|| ||Nominal lamp rating:<br>230 V incandescent/halogen W|2000<br>2000<br>3000|| ||fluorescent tubes with<br>electronic ballast W|1000<br>1000<br>1500|| ||fluorescent tubes with<br>electromechanical ballast W|750<br>750<br>1000|| ||CFL W|400<br>400<br>600<br>~~es~~|| ||230 V LED W|400<br>400<br>600<br>~~es~~|| ||LV halogen or LED with<br>electronic ballast W|400<br>400<br>600|| ||LV halogen or LED with<br>electromechanical ballast W|800<br>800<br>1500|| ||Minimum switchingload<br>mW (V/mA)|1000 (10/10)<br>1000 (10/10)<br>1000 (10/10)<br>~~es~~|| |**K**|Standard contact material<br>**Supply specification**|AgSnO2<br>AgSnO2<br>AgSnO2|| ||Nominal voltage (UN)<br>V AC (50/60 Hz)|110…125<br>230…240<br>—<br>110…240|| ||V DC/AC (50/60 Hz)<br>Ratedpower AC/DC<br>V A (50/60 Hz)/W<br>Operating range<br>V AC (50 Hz)<br>V DC/AC (50 Hz)<br>**Technical data**<br>Electrical life at rated load in AC1<br>cycles<br>Maximum impulse duration<br>Dielectric strength between: open contacts V AC<br>supply- contacts V AC<br>Ambient temperature range<br>°C<br>Protection category<br>**Approvals**(according to type)|12<br>24<br>12…24<br>—<br>2.5/2.5<br>1/0.5<br>3.2/1<br>90…130<br>184…253<br>—<br>90…264<br>10.8…13.2<br>20.6…33.6<br>10.2…26.4<br>—<br>100 · 103<br>100 · 103<br>100 · 103<br>continuous<br>continuous<br>continuous<br>1000<br>1000<br>1000<br>4000<br>2000<br>2000<br>–10…+60<br>–10…+60<br>–10…+60<br>IP 20<br>IP 20<br>IP 20<br>~~a~~<br>~~—ee~~<br>~~es~~<br>~~es~~<br>~~ee~~<br>~~es~~<br>~~es~~<br>~~ee~~<br>~~es~~<br>~~es~~<br>~~rs~~<br>~~rn~~<br>C€ Al|XI-2017, www.findernet.com| **4** **13 SERIES** - **13.11 - Call & Reset Relay - Rail mount - 1 Pole 13.12 - Call & Reset Relay - Rail mount - 2 Pole** - **13.31 - Electromechanical monostable relay Switch box mount - 1 Pole** - Call relay with reset command suitable for residential and commercial applications: public bathroom, hospital, hotel (type 13.11/13.12) - Can be mounted behind blanking plates, as widely used in residential wiring systems such as; BTicino: Axolute, Matix, Living e Magic, Gewiss: GW24, Vimar: Plana e Idea … (13.31) - 35 mm rail (EN 60715) or flange mount (13.11 and 13.12) - Cadmium free contact material (13.31) **==> picture [252 x 136] intentionally omitted <==** **----- Start of picture text -----**<br> 13.11 13.12 13.31<br>ag GE<br>AY,<br>om Sree<br>¢ eece<br>Ls @<br>• 1 CO (SPDT) + 1 NO (SPST-NO) • 1 NO (SPST-NO)<br>**----- End of picture text -----**<br> - 1 CO (SPDT) - Call relay with reset command - Call relay with reset command • Interposing monostable relay - 35 mm rail (EN 60715) mount - 35 mm rail (EN 60715) mount • For mounting within • 17.5 mm wide residential switch boxes - 17.5 mm wide ## 13.11/12/31 Screw terminals **==> picture [508 x 450] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||||| |---|---|---|---|---|---|---|---| |* During impulse only.| |For outline drawing see page 12| |Contact specification| |Contact configuration|1 CO (SPDT)|1 CO (SPDT) + 1 NO (SPST-NO)|1 NO (SPST-NO)| |Rated current/Maximum peak current|A|sd|12/30|8/15|12/20 (80 A - 5 ms)| |Rated voltage/| |Maximum switching voltage|V AC|250/400|250/400|250/400| |Rated load AC1|VA|3000|2000|3000| |a| |Rated load AC15 (230|V AC)|VA|750|400|450| |a| |Nominal lamp rating:| |230 V incandescent/halogen W|1200|800|800| |fluorescent tubes with| |electronic ballast W|500|300|400| |fluorescent tubes with| |electromechanical ballast W|400|250|300| |CFL W|300|150|200| |es| |230 V LED W|300|150|200| |a| |LV halogen or LED with| |electronic ballast W|300|150|200| |LV halogen or LED with| |electromechanical ballast W|500|300|400| |Minimum switching load|mW (V/mA)|a|500 (5/5)|300 (5/5)|1000 (10/10)| |Standard contact material|AgCdO|AgCdO|AgSnO2| |Supply specification| |Nominal voltage (UN)|V AC (50/60 Hz)|230…240|12 - 24|12 - 230| |V DC|—|12 - 24|24| |a| |Rated power AC/DC|V A (50 Hz)/W|a|1.7/0.7*|3/2.5*|1/0.4| |Operating range|AC (50 Hz)|a|(0.8…1.1)UN|(0.8…1.1)UN|(0.8…1.1)UN| |DC|—|(0.8…1.1)UN|(0.8…1.1)UN| |Technical data| |Electrical life at rated load in AC1|cycles|100 · 10|[3]|100 · 10|[3]|70 · 10|[3]| |Maximum impulse duration|ee|10 s (100 ms minimum)|10 s (100 ms minimum)|continuous| |Dielectric strength between: open contacts V AC|a|1000|1000|1000| |supply - contacts V AC|a|2000|2000|2000| |Ambient temperature range|°C|a|–10…+60|–10…+60|–10…+60| |Protection category|IP 20|IP 20|IP 20| |O™—OCC|TTTTTTCCSmOCOCSCSC“‘CSC*”| |Approvals|(according to type)|C€|EAL| **----- End of picture text -----**<br> **K** **5** **13 SERIES** ## **Ordering information** Example: 13 series, electronic step/monostable relay, 35 mm rail (EN 60715) mount, 1 CO (SPDT) 16 A contact, 230 V AC supply. ## **A B C D 1 3 . 0 1 . 8 . 2 3 0 . 0 0 0 0** ## **0 0 0** ## **Series** ## **Type** - 0 = Step/Monostable, 35 mm rail (EN 60715) mount, 35 mm wide - 1 = Call & Reset relay, 35 mm rail (EN 60715) mount, 17.5 mm wide - 3 = Monostable relay, switch box mounting - 6 = Multifunction relay, 35 mm rail (EN 60715) mount, 17.5 mm wide - 8 = Modular step relay, 35 mm rail (EN 60715) mount, 17.5 mm wide - 9 = Step relay and timing step relay, switch box mounting ## **No. of poles** - 1 = 1 pole - 2 = 1 pole CO (SPDT) + 1 NO (SPST-NO) ## **Supply version** 0 = AC (50/60 Hz)/DC 8 = AC (50/60 Hz) - 9 = DC **A: Contact material** 0 = Standard 4 = Standard AgSnO2 (only for 13.31) **B: Contact circuit** - 0 = Standard - 3 = Standard NO (only for 13.31) ## **Codes / Supply voltage** 13.01.0.012.0000 12 V AC/DC 13.01.0.024.0000 24 V AC/DC 13.01.8.125.0000 110…125 V AC 13.01.8.230.0000 230…240 V AC 13.11.8.230.0000 230…240 V AC 13.12.0.012.0000 12 V AC/DC 13.12.0.024.0000 24 V AC/DC 13.31.8.012.4300 12 V AC 13.31.9.024.4300 24 V DC 13.31.8.230.4300 230 V AC 13.61.8.230.0000 110…240 V AC 13.61.0.024.0000 12…24 V AC/DC 13.81.8.230.0000 230 V AC 13.91.8.230.0000 230 V AC ## **Supply voltage** 012 = 12 V AC/DC (13.01 and 13.12 only) 012 = 12 V AC (13.31 only) 024 = 24 V AC/DC (13.01 and 13.12 only) 024 = 24 V DC (13.31 only) 024 = 12…24 V AC/DC (13.61 only) 125 = (110…125)V AC (13.01 only) 230 = (230…240)V AC (13.01 and 13.11) 230 = 110…240 V AC (13.61 only) 230 = 230 V AC (13.31, 13.81 and 13.91) ## **Technical data** |**Insulation**<br>Dielectric strength<br>between control circuit and supply<br>V AC <br>between control circuit and contacts<br>V AC <br>between R-S-A2 and contacts<br>V AC <br>between supplyand contacts<br>V AC <br>between open contacts<br>V AC <br>**Other data**<br>Power lost to the environment<br>without contact current<br>W<br>with rated current<br>W<br>~~——=~~|**13.01.8**<br> 4000|**13.01.0**<br>—|**13.11 - 13.12**<br>—|**13.31 - 13.61**<br>—|**13.31 - 13.61**<br>—|**13.31 - 13.61**<br>—|**13.81 - 13.91**<br>—|**13.81 - 13.91**<br>—| |---|---|---|---|---|---|---|---|---| ||4000<br>~~——=~~|4000<br>~~——=~~|—<br>~~——=~~|—<br>~~——=~~|||—<br>~~——=~~|| ||—<br>~~——=~~|—<br>~~——=~~|2000<br>~~——=~~|—<br>~~——=~~|||—<br>~~——=~~|| ||4000<br>~~——=~~|4000<br>~~——=~~|—<br>~~——=~~|2000<br>~~——=~~|||—<br>~~——=~~|| ||1000<br>1000<br>**13.01**<br>2.2<br>3.5<br>~~——=~~||1000<br>**13.11 - 13.12**<br>—<br>~~——=~~|1000<br>**13.31**<br>**13.61**<br>0.4<br>1<br>~~——=~~|||1000<br>**13.81**<br>**13.91**<br>1.2<br>0.7<br>~~——=~~|| ||||1,5<br>~~——=~~|1.6<br>~~——=~~|1.8<br>~~——=~~||2<br>~~——=~~|1.8| |Max cable lenght forpush-button connection m<br>~~——=~~|100<br>~~——=~~||100<br>~~——=~~|—<br>~~——=~~|200<br>~~——=~~||200<br>~~——=~~|100| |Max. no. of illuminated push-button<br>(≤1mA)<br>**Terminals**<br>Max. wire size<br>mm2 <br>AWG|—<br>**13.01**<br>solid cable<br>stranded cable||—<br>—<br>10*<br>15<br>12<br>**13.11 - 13.12 - 13.31 - 13.61 - 13.81 - 13.91**<br>solid cable<br>stranded cable|||||| ||1 x 6 / 2 x 4|1 x 6 / 2 x 2.5|1 x 6 / 2 x 4|||1 x 4 / 2 x 2.5||| ||1 x 10 / 2 x 12<br>1 x 10 / 2 x 14<br> 0.8||1 x 10 / 2 x 12<br>1 x 12 / 2 x 14|||||| |Screw torque<br>Nm|||0.8|||||| **13 SERIES** **K** ## **Functions** **Type 13.01 Monostable** On closure of a switch between terminals (B2-B3) the output contact will close, and remain so, until the switch opens. **Step relay (bistable)** After every impulse (B1-B2), the output contact changes state - alternately switching from open to closed and vice versa. **13.11 Call and Reset relay 13.12** On momentary closure of the Set switch (S), the output contact closes. Only a momentary closure of the Reset switch (R) will open the output contact. (13.12 only) **13.81 (RI) Step relay** After every impulse, the output contact changes state - alternately switching from open to closed and vice versa. **13.91 (RI) Step relay** After every impulse, the output contact changes state - alternately switching from open to closed and vice versa. **(IT) Timing step relay** On initial impulse the output contact closes and timing starts for the pre-set duration (fixed 10 min); On expiry of the time delay, the output contact opens. During the timing period it is possible to immediately open the contact with a further impulse. ## **Operating mode setup for type 13.91** **RI** → **IT IT** → **RI** **==> picture [184 x 102] intentionally omitted <==** a) Remove the supply voltage b) Press the control button - c) Apply the supply to the relay, keeping the button closed. After 3 second, the light will flash twice to indicate the selection of the “IT” function, or flash once for “RI” function. **7** **13 SERIES** ## **Functions** **K** ## **Type** ## **13.61.8.230** ## **13.61.0.024** ## **Functions** **==> picture [198 x 143] intentionally omitted <==** **==> picture [198 x 518] intentionally omitted <==** ## **(RM) Monostable** On closure of a switch between terminal 3 and Line (or Neutral, in case of 3-wire connection) the output contact will close, and remain so, until the switch opens. ## **(IT) Timing step relay** On initial impulse the output contact closes and timing starts for the pre-set duration T; On expiry of the time delay, the output contact opens. During the timing period it is possible to immediately open the contact with a further impulse. Switch-off delay time: 30s…20min ## **(RI) Step relay** After every impulse, the output contact changes state - alternately switching from open to closed and vice versa. ## **Light ON** With this function set - the output contact stays permanently closed. ## **(RM) Monostable** On closure of a switch between terminal 3 and Line (or Neutral, in case of 3-wire connection) the output contact will close, and remain so, until the switch opens. ## **(IT) Timing step relay** On initial impulse the output contact closes and timing starts for the pre-set duration T; On expiry of the time delay, the output contact opens. During the timing period it is possible to immediately open the contact with a further impulse. Switch-off delay time: 30s…20min ## **(RI) Step relay** After every impulse, the output contact changes state - alternately switching from open to closed and vice versa. ## **Light ON** With this function set - the output contact stays permanently closed. **8** **13 SERIES** **K** ## **Wiring diagrams (13.01, 13.11, 13.12 and 13.31)** **==> picture [349 x 211] intentionally omitted <==** **----- Start of picture text -----**<br> Type 13.01 Type 13.01<br>Step wiring diagram Monostable wiring diagram<br>Red LED indication: Red LED indication:<br>Continuous = relay ON Continuous = relay ON<br>**----- End of picture text -----**<br> **==> picture [136 x 138] intentionally omitted <==** **==> picture [216 x 189] intentionally omitted <==** **----- Start of picture text -----**<br> Type 13.11<br>Call & reset relay<br>Reset<br>Set<br>**----- End of picture text -----**<br> **==> picture [56 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Type 13.12<br>Call & reset relay<br>**----- End of picture text -----**<br> **==> picture [182 x 179] intentionally omitted <==** **----- Start of picture text -----**<br> Reset<br>Set<br>**----- End of picture text -----**<br> **Type 13.31** Connection **==> picture [86 x 88] intentionally omitted <==** **9** **13 SERIES** ## **Wiring diagrams (13.61)** **Type 13.61.8.230** 3 wire connection Red LED indication: Continuous = relay ON Blinking = relay OFF **Type 13.61.8.230** 4 wire connection Red LED indication: Continuous = relay ON Blinking = relay OFF **==> picture [510 x 211] intentionally omitted <==** **----- Start of picture text -----**<br> Reset Reset<br>Max 10 (≤ 1 mA) Max 10 (≤ 1 mA)<br>illuminated push buttons illuminated push buttons<br>**----- End of picture text -----**<br> **==> picture [291 x 189] intentionally omitted <==** **----- Start of picture text -----**<br> Type 13.61.0.024 L (+)<br>4 wire connection 12…24 V AC/DC<br>Red LED indication: N (-)<br>Continuous = relay ON Reset<br>Blinking = relay OFF<br>Set<br>**----- End of picture text -----**<br> **Type 13.61.8.230 - Examples of multiple 4 wire connection with centralized reset pushbutton** **K** **==> picture [471 x 217] intentionally omitted <==** **10** **13 SERIES** **K** ## **Wiring diagrams (13.81 and 13.91)** **Type 13.81** 3 wire connection Red LED indication: Continuous = relay ON Blinking = relay OFF **==> picture [85 x 116] intentionally omitted <==** Max 15 (≤ 1 mA) illuminated push buttons **Type 13.91** 3 wire connection **==> picture [162 x 149] intentionally omitted <==** Max 12 (≤ 1 mA) illuminated push buttons **Type 13.81** 4 wire connection Red LED indication: Continuous = relay ON Blinking = relay OFF **==> picture [167 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> L<br>N<br>Max 15 (≤ 1 mA)<br>illuminated push buttons<br>**----- End of picture text -----**<br> **Type 13.91** 4 wire connection **==> picture [163 x 136] intentionally omitted <==** Max 12 (≤ 1 mA) illuminated push buttons **11** **13 SERIES** ## **Outline drawings** **K** 13.01 Screw terminal **==> picture [39 x 39] intentionally omitted <==** **==> picture [43 x 102] intentionally omitted <==** **==> picture [69 x 102] intentionally omitted <==** **==> picture [50 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> 13.12<br>Screw terminal<br>**----- End of picture text -----**<br> **==> picture [115 x 183] intentionally omitted <==** 13.61 Screw terminal **==> picture [106 x 178] intentionally omitted <==** 13.11 Screw terminal **==> picture [39 x 39] intentionally omitted <==** **==> picture [183 x 170] intentionally omitted <==** **----- Start of picture text -----**<br> 17.5 4.3 56.5<br>13.31/13.91<br>Screw terminal<br>33.8 45 84<br>88.8<br>30.5<br>**----- End of picture text -----**<br> **==> picture [39 x 39] intentionally omitted <==** **==> picture [128 x 87] intentionally omitted <==** **==> picture [52 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> 13.81<br> Screw terminal<br>**----- End of picture text -----**<br> **==> picture [175 x 178] intentionally omitted <==** **12** **13 SERIES** **K** |**Accessories**||| |---|---|---| ||**Adaptor for panel mounting,**for type 13.01, 35 mm wide|011.01| |**011.01**||| ||**Adaptor for panel mounting,**for type 13.11, 13.12, 13.61 and 13.81, 17.5 mm wide|020.01| |**020.01**||| |**Sheet of marker tags (CEMBRE Thermal transfer printers)**for relays types<br>13.11, 13.12, 13.61 and 13.81 (48 tags), 6 x 12 mm<br>a<br>-<br>t<br>-<br>-<br>t<br>es<br>es<br>+<br>te<br>a<br>-<br>-<br>t<br>-<br>+<br>&||060.48| |-<br>-<br>-||| |-<br>-||| |7<br>=<br>-||| |-<br>-<br>-<br>**t-**<br>| aa<br>|o<br>a||| |Pees||| |**060.48**||| Please see general technical information **13**
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →