1182P30
TRANSFORMER, TOROID, 60V, 300VA
- Manufacturer: HAMMOND
- Product type: Toroidal Power Transformers
- Power R; TRANSFORMER, TOROID, 60V, 300VA; Power Rating:300VA; Secondary Voltages:30V, 60V; Winding Type:Dual Primary, Dual Secondary; Toroid Center:Open; Transformer Mounting:Chassis Moun
- SVHC: No SVHC (25-Jun-2025)
- Height: 47.8mm
- Power Rating: 300VA
- Winding Type: Dual Primary, Dual Secondary
- Product Range: 1182 Series
- Toroid Centre: Open
- Outer Diameter: 124mm
- Primary Voltages: 117V, 234V
- Secondary Voltages: 30V, 60V
- Transformer Mounting: Chassis Mount
- Secondary Current Nom: 10A
- Transformer Terminals: Wire Leaded
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 68.5 € |
| Current stock | 10+ |
| Lead time | 7 days |
Quality Products. Service Excellence. ## **Toroid Power Transformers 1182 Series** ## **Features** Torodial transformer benefits: low profile - lightweight - cool running / high efficiency - due to the core shape - low stray magnetic flux leakage (low EMI) - Dual 117/234 VAC primary, 50/60 Hz. operation. Note: Units are designed to have all windings engaged (either series or parallel connected) or connected as an autotransformer. Connection sheet included with transformer. See Product Resources for Download. Supplied with two rubber insulating pads, one metal centering washer and all mounting hardware (except the 1,500 VA size). - 1,500 VA size - is supplied with a potted center for extra strength. Minimum 8" long flexible leads - Manufactured using Class B (130 degree C) materials. - Hi-Pot test of 4,000VAC RMS between primary & secondary - UL recognized to UL506 (XPTQ2.Guide) UL file #E207860 CSA certified to C22.2 #66 - CSA file #209651 - CE compliant to IEC 61558-2-4 - This series replaces our older **182 Toroid Series** . ## **Note about Inrush Current:** Due to the superior magnetic properties of Toroidal transformers they will be susceptible to high magnetizing current when initially energized, only limited by the low DC resistance of the primary winding. Depending on where you are in the AC cycle when the transformer is energized dictates the chances of overloading the supply circuit. This is why the transformer may sometimes energize without a problem and other times it will blow the fuse or trip the circuit breaker. The duration of this overload is rarely longe than a half of a cycle. Therefore, you should consider using a slow-blow fuse, time delayed circuit breaker or other form of soft start circuitry for the supply line when using these high efficient Toroidal transformers. ## **Gallery** |||**VAC Secondary (RMS)**|**VAC Secondary (RMS)**|**Dual or Single**|**% Voltage**|**Toroid**|**Dim.**| |---|---|---|---|---|---|---|---| |**Part No.**|**VA**|**Series**|**Parallel**|**Secondary**|**Regulation**|**Center**|**Ref**| |**1182L6**|30|12V C.T. @ 2.5A|6V @ 5A|Dual|11.70%|Open|B| |**1182N6**|50|12V C.T. @ 4.17A|6V @ 8.34A|Dual|12.60%|Open|C| |**1182Q6**|80|12V C.T. @ 6.67A|6V @ 13.34A|Dual|9.70%|Open|D| |**1182K9**|30|18V C.T. @ 1.67A|9V @ 3.34A|Dual|12.80%|Open|B| |**1182M9**|50|18V C.T. @ 2.78A|9V @ 5.56A|Dual|13.20%|Open|C| |**1182N9**|80|18V C.T. @ 4.44A|9V @ 8.88A|Dual|10.50%|Open|D| |**1182Q9**|120|18V C.T. @ 6.67A|9V @ 13.34A|Dual|9.00%|Open|E| |**1182K12**|30|24V C.T. @ 1.25A|12V @ 2.5A|Dual|11.70%|Open|B| |**1182L12**|50|24V C.T. @ 2.08A|12V @ 4.16A|Dual|12.60%|Open|C| |**1182M12**|80|24V C.T. @ 3.33A|12V @ 6.66A|Dual|9.70%|Open|D| |**1182P12**|120|24V C.T. @ 5A|12V @ 10A|Dual|7.70%|Open|E| |**1182Q12**|160|24V C.T. @ 6.67A|12V @ 13.34A|Dual|7.70%|Open|F| |**1182S12**|225|24V C.T. @ 9.38A|12V @ 18.76A|Dual|7.20%|Open|G| |**1182T12**|300|24V C.T. @ 12.5A|12V @ 25A|Dual|7.10%|Open|H| |**1182W12**|1000|24V C.T. @ 41.7A|12V @ 83.4A|Dual|2.20%|Open|L-1| |**1182J15**|30|30V C.T. @ 1A|15V @ 2A|Dual|12.30%|Open|B| |**1182K15**|50|30V C.T. @ 1.67A|15V @ 3.34A|Dual|13.00%|Open|C| |**1182M15**|80|30V C.T. @ 2.67A|15V @ 5.34A|Dual|10.20%|Open|D| |**1182N15**|120|30V C.T. @ 4A|15V @ 8A|Dual|8.50%|Open|E| |**1182P15**|160|30V C.T. @ 5.33A|15V @ 10.66A|Dual|7.00%|Open|F| |**1182H15**|225|30V C.T. @ 7.5A|15V @ 15A|Dual|7.20%|Open|G| |**1182S15**|300|30V C.T. @ 10A|15V @ 20A|Dual|5.00%|Open|H| |**1182H18**|30|36V C.T. @ 0.83A|18V @ 1.66A|Dual|12.20%|Open|B| |**1182J18**|50|36V C.T. @ 1.39A|18V @ 2.78A|Dual|13.80%|Open|C| |**1182L18**|80|36V C.T. @ 2.22A|18V @ 4.44A|Dual|10.50%|Open|D| |**1182M18**|120|36V C.T. @ 3.33A|18V @ 6.66A|Dual|7.70%|Open|E| |**1182N18**|160|36V C.T. @ 4.44A|18V @ 8.88A|Dual|7.70%|Open|F| |**1182G18**|225|36V C.T. @ 6.25A|18V @ 12.5A|Dual|7.30%|Open|G| |**1182G22**|30|44V C.T. @ 0.68A|22V @ 1.36A|Dual|12.60%|Open|B| |**1182J22**|50|44V C.T. @ 1.14A|22V @ 2.28A|Dual|14.20%|Open|C| |**1182L22**|80|44V C.T. @ 1.82A|22V @ 3.64A|Dual|10.40%|Open|D| |**1182M22**|120|44V C.T. @ 2.73A|22V @ 5.46A|Dual|8.40%|Open|E| |**Part No.**|**VA**<br>**VAC Secondary (RMS)**<br>**Dual or Single**<br>**% Voltage**<br>**Toroid**<br>**Dim.**<br>**Series**<br>**Parallel**<br>**Secondary**<br>**Regulation**<br>**Center**<br>**Ref**| |---|---| |**1182N22**|160<br>44V C.T. @ 3.64A<br>22V @ 7.28A<br>Dual<br>8.40%<br>Open<br>F| |**1182P22**|225<br>44V C.T. @ 5.11A<br>22V @ 10.22A<br>Dual<br>6.40%<br>Open<br>G| |**1182S24**|500<br>48V C.T. @ 10.42A<br>24V @ 20.82A<br>Dual<br>5.10%<br>Open<br>I| |**1182T24**|625<br>48V C.T. @ 13.02A<br>24V @ 26.04A<br>Dual<br>3.30%<br>Open<br>J| |**1182U24**|750<br>48V C.T. @ 15.63A<br>24V @ 31.26A<br>Dual<br>3.60%<br>Open<br>L| |**1182V24**|1000<br>48V C.T. @ 20.8A<br>24V @ 41.7A<br>Dual<br>2.20%<br>Open<br>L| |**1182K30**|80<br>60V C.T. @ 1.33A<br>30V @ 2.66A<br>Dual<br>9.70%<br>Open<br>D| |**1182L30**|120<br>60V C.T. @ 2A<br>30V @ 4A<br>Dual<br>7.70%<br>Open<br>E| |**1182M30**|160<br>60V C.T. @ 2.67A<br>30V @ 5.34A<br>Dual<br>7.70%<br>Open<br>F| |**1182F30**|225<br>60V C.T. @ 3.75A<br>30V @ 7.5A<br>Dual<br>6.30%<br>Open<br>G| |**1182P30**|300<br>60V C.T. @ 5A<br>30V @ 10A<br>Dual<br>6.10%<br>Open<br>H| |**1182R30**|500<br>60V C.T. @ 8.33A<br>30V @ 16.66A<br>Dual<br>4.80%<br>Open<br>I| |**1182S30**|625<br>60V C.T. @ 10.42A<br>30V @ 20.84A<br>Dual<br>4.10%<br>Open<br>J| |**1182T30**|750<br>60V C.T. @ 12.5A<br>30V @ 25A<br>Dual<br>3.10%<br>Open<br>K| |**1182U30**|1000<br>60V C.T. @ 16.7A<br>30V @ 33.3A<br>Dual<br>2.20%<br>Open<br>L| |**1182V40P**|1500<br>80V C.T. @ 18.8A<br>40V @ 37.5A<br>Dual<br>3.70%<br>Potted<br>M| |||**VAC Secondary (RMS)**|**VAC Secondary (RMS)**|**Dual or Single**|**% Voltage**|**Toroid**|**Dim.**| |---|---|---|---|---|---|---|---| |**Part No.**|**VA**|**Series**|**Parallel**|**Secondary**|**Regulation**|**Center**|**Ref**| |**1182L60**|300|120V C.T. @ 2.5A|60V @ 5A|Dual|6.10%|Open|H| |**1182N60**|500|120V C.T. @ 4.17A|60V @ 8.34A|Dual|4.80%|Open|I| |**1182P60**|625|120V C.T. @ 5.21A|60V @ 10.42A|Dual|4.10%|Open|J| |**1182Q60**|750|120V C.T. @ 6.25A|60V @ 12.5A|Dual|4.10%|Open|K| |**1182R60**|1000|120V C.T. @ 8.3A|60V @ 16.7A|Dual|2.80%|Open|L| |**1182T60P**|1500|120V C.T. @ 12.5A|60V @ 25A|Dual|3.00%|Potted|M| |**1182E110**|30|220V C.T. @ 136ma|110V @ 272ma|Dual|13.10%|Open|B| |**1182G110**|50|220V C.T. @ 227ma|110V @ 454ma|Dual|14.10%|Open|C| |**1182H110**|80|220V C.T. @ 364ma|110V @ 728ma|Dual|10.50%|Open|D| |**1182J110**|120|220V C.T. @ 545ma|110V @ 1.09A|Dual|8.40%|Open|E| |**1182K110**|160|220V C.T. @ 727ma|110V @ 1.45A|Dual|8.00%|Open|F| |**1182L110**|225|220V C.T. @ 1.02A|110V @ 2.04A|Dual|6.10%|Open|G| |**1182M110**|300|220V C.T. @ 1.36A|110V @ 2.72A|Dual|6.10%|Open|H| |**1182P110**|500|220V C.T. @ 2.27A|110V @ 4.54A|Dual|4.70%|Open|I| |**1182Q110**|625|220V C.T. @ 2.84A|110V @ 5.68A|Dual|3.70%|Open|J| |**1182R110**|750|220V C.T. @ 3.41A|110V @ 6.82A|Dual|3.10%|Open|K| |**1182S110**|1000|220V C.T. @ 4.5A|110V @ 9.1A|Dual|3.20%|Open|L| |**1182U110P**|1500|220V C.T. @ 6.8A|110V @ 13.6A|Dual|1.90%|Potted|M| |**1182E117**|30|234V C.T. @ 128ma|117V @ 256ma|Dual|12.40%|Open|B| |**1182G117**|50|234V C.T. @ 214ma|117V @ 428ma|Dual|13.40%|Open|C| |**1182H117**|80|234V C.T. @ 342ma|117V @ 684ma|Dual|10.00%|Open|D| |**1182J117**|120|234V C.T. @ 513ma|117V @ 1.02A|Dual|8.00%|Open|E| |**1182K117**|160|234V C.T. @ 684ma|117V @ 1.37A|Dual|7.60%|Open|F| |**1182L117**|225|234V C.T. @ 0.96A|117V @ 1.92A|Dual|6.00%|Open|G| |**1182M117**|300|234V C.T. @ 1.28A|117V @ 2.56A|Dual|5.80%|Open|H| |**1182N117**|500|234V C.T. @ 2.14A|117V @ 4.28A|Dual|4.70%|Open|I| |**1182P117**|625|234V C.T. @ 2.67A|117V @ 5.34A|Dual|3.80%|Open|J| |**1182Q117**|750|234V C.T. @ 3.21A|117V @ 6.42A|Dual|3.60%|Open|K| |**1182R117**|1000|234V C.T. @ 4.27A|117V @ 8.5A|Dual|3.00%|Open|L| |**1182T117P**|1500|234V C.T. @ 6.4A|117V @ 12.8A|Dual|2.10%|Potted|M| |**1182D240**|30|-|240V @ 125ma|Single|12.30%|Open|B| |**1182E240**|50|-|240V @ 208ma|Single|13.10%|Open|C| |**1182F240**|80|-|240V @ 333ma|Single|9.90%|Open|D| |**1182G240**|120|-|240V @ 0.5A|Single|7.90%|Open|E| |**Part No.**|**VA**<br>**VAC Secondary (RMS)**<br>**Dual or Single**<br>**% Voltage**<br>**Toroid**<br>**Dim.**<br>**Series**<br>**Parallel**<br>**Secondary**<br>**Regulation**<br>**Center**<br>**Ref**| |---|---| |**1182H240**|160<br>-<br>240V @ 667ma<br>Single<br>7.70%<br>Open<br>F| |**1182J240**|225<br>-<br>240V @ 0.94A<br>Single<br>5.80%<br>Open<br>G| |**1182K240**|300<br>-<br>240V @ 1.25A<br>Single<br>5.80%<br>Open<br>H| |**1182L240**|500<br>-<br>240V @ 2.08A<br>Single<br>4.80%<br>Open<br>I| |**1182M240**|625<br>-<br>240V @ 2.6A<br>Single<br>3.70%<br>Open<br>J| |**1182N240**|750<br>-<br>240V @ 3.13A<br>Single<br>3.60%<br>Open<br>K| |**1182P240**|1000<br>-<br>240V @ 4.17A<br>Single<br>2.80%<br>Open<br>L| |**1182Q240P**|1500<br>-<br>240V @ 6.3A<br>Single<br>2.30%<br>Potted<br>M| ## **Mechanical & Schematic Data** |**Dimension**<br>**VA**<br>**Outside**<br>**Height**<br>**Inside**<br>**Potted**<br>**Included Mounting**<br>**Weight**<br>**Reference Size Diameter**<br>**Diameter Center**<br>**Hardware**<br>**(lbs.) (kg.)**|**Dimension**<br>**VA**<br>**Outside**<br>**Height**<br>**Inside**<br>**Potted**<br>**Included Mounting**<br>**Weight**<br>**Reference Size Diameter**<br>**Diameter Center**<br>**Hardware**<br>**(lbs.) (kg.)**| |---|---| |B|30<br>3.00<br>1.25<br>1.50<br>No<br>10-24 x 1.75" bolt, with metal centering washer, nut, lockwasher & two<br>(2) rubber insulating pads<br>1.1<br>0.5| |C|50<br>3.25<br>1.50<br>1.25<br>No<br>10-24 x 2.00" bolt, with metal centering washer, nut, lockwasher & two<br>(2) rubber insulating pads<br>1.5<br>0.7| |D|80<br>3.50<br>1.50<br>1.60<br>No<br>10-24 x 2.00" bolt, with metal centering washer, nut, lockwasher & two<br>(2) rubber insulating pads<br>2.1<br>1| |E|120<br>3.75<br>1.63<br>1.45<br>No<br>10-24 x 2.00" bolt, with metal centering washer, nut, lockwasher & two<br>(2) rubber insulating pads<br>3<br>1.3| |F|160<br>4.25<br>1.75<br>1.70<br>No<br>1/4-20 x 2.50" bolt, with metal centering washer, nut, lockwasher &<br>two (2) rubber insulating pads<br>3.8<br>1.7| |G|225<br>4.50<br>1.88<br>1.62<br>No<br>1/4-20 x 2.50" bolt, with metal centering washer, nut, lockwasher &<br>two (2) rubber insulating pads<br>4.7<br>2.1| |H|300<br>4.88<br>1.88<br>1.85<br>No<br>1/4-20 x 2.50" bolt, with metal centering washer, nut, lockwasher &<br>two (2) rubber insulating pads<br>6<br>2.7| |I|500<br>5.50<br>2.25<br>2.30<br>No<br>1/4-20 x 3.00" bolt, with metal centering washer, nut, lockwasher &<br>two (2) rubber insulating pads<br>9<br>4.1| |J|625<br>5.88<br>2.38<br>2.45<br>No<br>1/4-20 x 3.00" bolt, with metal centering washer, nut, lockwasher &<br>two (2) rubber insulating pads<br>10.8<br>4.9| |K|750<br>5.88<br>2.88<br>2.45<br>No<br>3/8-16 x 3.50" bolt, with metal centering washer, nut, lockwasher &<br>two (2) rubber insulating pads<br>12.9<br>5.8| |L|1000<br>6.25<br>2.88<br>2.35<br>No<br>3/8-16 x 3.50" bolt, with metal centering washer, nut, lockwasher &<br>two (2) rubber insulating pads<br>16.3<br>7.4| |L-1|1000<br>6.85<br>3.40<br>2<br>No<br>3/8-16 x 3.50" bolt, with metal centering washer, nut, lockwasher &<br>two (2) rubber insulating pads<br>16.3<br>7.4| |M|1500<br>7.25<br>3.25<br>Potted<br>Yes<br>3/8-16 x 3.50" bolt, with nut, lockwasher & one (1) rubber bottom<br>insulating pad<br>23.2<br>10.5| ## **Additional Hardware Kits:** |||**Additional Hardware Kit**|**Metal Washer**|**Metal Washer**||| |---|---|---|---|---|---|---| |||**(included with transformers)**||**Steel**|**Rubber**|**Washer**| |**Part No.**||**For Use With**|**Diameter**|**Gauge **|**Diameter **|**Thickness**| |**1182KIT30**|30VA Models|10-24 x 1.75" bolt, with metal centering washer, nut,|2.37|18|2.50|0.06| |||lockwasher & two (2) rubber insulating pads||||| |**1182KIT50**|50VA, 80VA & 120VA|10-24 x 2.00" bolt, with metal centering washer, nut,|2.37|18|2.50|0.06| ||Models|lockwasher & two (2) rubber insulating pads||||| |**1182KIT160**|160VA, 225VA & 300VA|1/4-20 x 2.50" bolt, with metal centering washer, nut,|3.56|16|3.75|0.06| ||Models|lockwasher & two (2) rubber insulating pads||||| |**1182KIT500**|500VA & 625VA Models|1/4-20 x 3.00" bolt, with metal centering washer, nut,|4.30|16|4.75|0.09| |||lockwasher & two (2) rubber insulating pads||||| |**1182KIT750**|750VA & 1,000VA|3/8-16 x 3.50" bolt, with metal centering washer, nut,|4.30|16|4.75|0.09| ||Models|lockwasher & two (2) rubber insulating pads||||| |**1182KIT1500P**|1,500VA Models|3/8-16 x 4.00" bolt, nut & lockwasher|N/A||N/A|| ||||**Additional Hardware Kit**|**Metal Washer**|**Metal Washer**|||| |---|---|---|---|---|---|---|---|---| ||||**(included with transformers)**||**Steel**|**Rubber**|**Washer**|| ||**Part No.**||**For Use With**|**Diameter**|**Gauge **|**Diameter **|**Thickness**|| ||**1182KIT1500**|Heavy Duty - Upgrade|3/8-16 x 4.50" bolt, with metal centering washer, nut,|4.30|16|6.00|0.12|| |||Kit 1,500VA Models|lockwasher & two (2) rubber insulating pads|||||| Data subject to change without notice © 2016. Hammond Manufacturing Ltd. All rights reserved.
Updated at March 12, 2026
Hammond Manufacturing is a globally recognized producer of high-quality electronic components, widely respected for its robust enclosures, thermal management solutions, and power products. With a strong commitment to continuous improvement and high-performance manufacturing, the company delivers reliable solutions designed to meet the rigorous demands of original equipment manufacturers across the electrical and electronic industries. A significant focus of our Hammond portfolio centers on power conversion and delivery, featuring a dependable selection of toroidal power transformers. Engineered for high efficiency and low magnetic stray field emissions, these transformers are ideal for sensitive electronic equipment, audio applications, and demanding industrial power supplies. To complement their power delivery products, Hammond also excels in components that protect and maintain optimal operating conditions for electronic systems. Our offering includes essential cooling and thermal management solutions, specifically fan filter assemblies designed to safeguard equipment from dust while ensuring adequate airflow for fans and blowers. The range is further supported by durable battery holders, providing secure and dependable power integration for portable and hand-held devices.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →