1110-F112-P1M1-10A
Thermal Circuit Breaker, 1110, 10 A, 1 Pole, 28 V, 250 V, Panel
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: ETA
- Product type: Thermal Circuit Breakers
- Product Range:1110 Series; Current Rating:10A; No. of Poles:1 Pole; Voltage Rating V DC:28VDC; Voltage Rating VAC:250VAC; Circuit Breaker Mounting:Panel; SVHC:No SVHC (15-Jan-2018); Approval Bodies:
- No. of Poles: 1 Pole
- Product Range: 1110
- Current Rating: 10A
- Voltage Rating VAC: 250V
- Voltage Rating VDC: 28V
- Circuit Breaker Mounting: Panel
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 14.74 € |
| Current stock | 25+ |
| Lead time | 30 days |
**Thermal Overcurrent Circuit Breaker 1110-...** **1** ## **Description** Single pole switch/thermal circuit breaker (S-type TO CBE to EN 60934) with tease-free, trip-free, snap action mechanism. Designed for snapin panel mounting utilising round hole or industry standard fuseholder cut-out dimensions. Featuring an ergonomically styled two colour actuator with indicator band clearly showing the tripped/OFF position. Approved to CBE standard EN 60934 (IEC 60934). ## **Typical applications** Motors, transformers, solenoids, extra low voltage systems, household and office machines, instrumentation, marine applications, mobile homes. ## **1110-F1..** **Ordering information** 7, **Type No. 1110** snap in panel mounting Oo **Mounting F1** panel thickness 0.8...1.6 mm (.031 -.063 in) **F2** panel thickness 1.8...3 mm (.071-.118 in) Current rating **Number of poles** Typical life **1** 1 pole protected **Actuator style 2** black push button/white indicator ring, standard Ambient temp Other indicator ring colours are available to special order **Terminal design P1** blade terminals A6.3-0.8 (QC .250) **Characteristic curve M1** medium delay **Current ratings** Dielectric strength **0.05...16A** ## **Technical data** |**For further details please see chapter: Technical Information**<br>Voltage rating<br>Oo|**For further details please see chapter: Technical Information**<br>AC 250 V; DC 28 V<br>(UL: AC 250 V;DC 50 V)|**For further details please see chapter: Technical Information**<br>AC 250 V; DC 28 V<br>(UL: AC 250 V;DC 50 V)| |---|---|---| |Current ratingg|0.05...16 A|| |Typical life<br>AC + DC||| |0.05...10 A|10,000 operations at 1 x IN, inductive|| |12...16 A<br>Ambient tempperature|6,000 operations at 1 x IN,inductive<br>-20...+60 °C(-4...+140 °F)|| |Insulation co-ordination|rated impulse<br>pollution|| |(IEC 60664 and 60664 A)|withstand voltage<br>degree|| ||2.5 kV<br>2|| ||reinforced insulation in operatingarea|| |Dielectric strength||| |(IEC 60664 and 60664A)|test voltage|| |operatingarea|AC 3,000 V|| |Insulation resistance|> 100 MΩ(DC 500 V)|| |Interrupting capacity Icn|AC 250 V:<br>0.05...16 A|8 x IN| |~~—OCit—™~~|DC 28 V:<br>0.05...6 A<br>7...10 A<br>12...16 A<br>~~—OCit—™~~|10 x IN<br>200 A<br>300 A<br>~~—OCit—™~~| |Interrupting capacity|IN<br>UN|| |(UL 1077/EN60934 PC 1)|0.05...6 A<br>AC 250 V|1,000 A| |Degree of protection<br>(IEC 60529/DIN 40050)|7...16 A<br>AC 125 V<br>0.05...16 A<br>DC 50 V<br>operating area IP40<br>terminal area IP00|1,000 A<br>1,000 A| |Vibration 8 g (57-500 Hz)±0.61 mm (10-57 Hz),|Vibration 8 g (57-500 Hz)±0.61 mm (10-57 Hz),|| ||to IEC 60068-2-6, test Fc,|| ||10 frequencycycles/axis|| |Shock 30 g (11 ms)|Shock 30 g (11 ms)|| ||to IEC 60068-2-27,test Ea|| |Corrosion|96 hours at 5 % salt mist,<br>to IEC 60068-2-11,test Ka|| |Humidity|240 hours at 95 % RH|| ||to IEC 60068-2-3,test Ca|| |Mass a|Mass approx. 12g|| **1110 - F1 1 2 - P1 M1 - 0.05 A** = ordering example ## **Standard current ratings and typical internal resistance values** es |**Current**<br>**Internal**<br>**rating (A)**<br>**resistance(**Ω**)**|**Current**<br>**Internal**<br>**rating (A)**<br>**resistance(**Ω**)**| |---|---| |0.05<br>442|2<br>0.25| |0.08<br>173|2.5<br>0.19| |0.1<br>110|3<br>0.12| |0.2<br>27.8|3.5<br>0.09| |0.3<br>12.4|4<br>0.07| |0.4<br>7.0|5<br>0.05| |0.5<br>4.5|6<br>0.04| |0.6<br>3.1|7<br>≤0.02| |0.7<br>2.3|8<br>≤0.02| |0.8<br>1.7|10<br>≤0.02| |1.1|12<br>≤0.02| |1.2<br>0.71|15<br>≤0.02| |1.5<br>0.41|16<br>≤0.02| |1.8<br>0.38|| ## **Approvals** ~~EE~~ **Authority Voltage ratings Current ratings** BV AC 250 V; DC 28 V 0.05...16 A UL AC 250 V 0.05...6 A AC 125 V 7...16 A DC 50 V 0.05...16 A CSA AC 250 V; DC 50 V 0.05...16 A VDE AC 250 V 0.05...10 A 05/06(280405) **www.e-t-a.com** ~~LT~~ ## **Thermal Overcurrent Circuit Breaker 1110-...** **1** ## **Dimensions** ## **1110-F1.. / -F2..** **==> picture [235 x 319] intentionally omitted <==** **----- Start of picture text -----**<br> When installing the circuit breaker apply pressure on bezel only.<br>19 19<br>.748 .748<br>10 10<br>.394 .394 black<br>white<br>12.1<br>13.2<br>.476<br>15.6 .520<br>.61 blade terminals DIN 46244-A6.3-0.8<br>(QC .250)<br>Panel cut out<br>1110-F1..-P.M1-...A 1110-F2..-P.M1-...A<br>+0.2 +0.2<br>±0.05 - 0.4 ±0.05 - 0.4<br>±.002 +.008 ±.002 +.008<br>- .016 - .016<br>installation installation<br>side side<br>16 ±0.15 0.8 … 1.6 16 [±][0.15] 1.8 … 3<br>.630 [±][.006] .031 … .063 .630 [±][.006] .071 … .118<br>insertion force ≤ 20 N, removal force ≥ 120 N insertion force ≤ 40 N, removal force ≥ 120 N<br>OFF ON<br>2.4 .094<br>15 .591 9.5 .374<br>51 2.01 47.5 1.85<br>9<br>12.5 .492 .354<br>0.1± .004 ± 0.1± .004 ±<br>13.5 .531 13.5 .531<br>**----- End of picture text -----**<br> ## **Installation drawing** **==> picture [249 x 171] intentionally omitted <==** **----- Start of picture text -----**<br> When installing the circuit breaker apply pressure on bezel only.<br>operating area<br>3 3 25 25<br>.118 .118 .984 .984<br>mounting area<br>**----- End of picture text -----**<br> ## **Internal connection diagram** **==> picture [249 x 360] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>2<br>Typical time/current characteristics at +23°C/+73.4°F<br>10000 0.05 - 6 A<br>7 - 16 A<br>1000<br>100<br>10<br>1<br>0.1<br>0.6 0.8 1 2 4 6 8 10 20 40<br>… times rated current<br>Trip time in seconds<br>**----- End of picture text -----**<br> The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section 9 – Technical information. Ambient temperature °F -4 +14 +32 +73.4 +104 +122 +140 °C -20 -10 0 +23 +40 +50 +60 Derating factors 0.76 0.84 0.92 1 1.08 1.16 1.24 ## **Accessories - Water splash covers (transparent)** **==> picture [249 x 137] intentionally omitted <==** **----- Start of picture text -----**<br> Push button splash cover Terminal shroud<br>transparent Y 305 602 01 (IP64)<br>Y 304 745 01 (IP64) ø14.5 1.25<br>.571 .049<br>14<br>When using<br>splash cover .551<br>please note<br>that the max.<br>panel thickness<br>is reduced by0.5 mm/0.02 in. 20.5<br>.807<br>ø4<br>.157<br>17.8 .701 60 2.36<br>**----- End of picture text -----**<br> All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. This is a metric design and millimeter dimensions take precedence ~~(~~[mm ] inch ~~)~~ 05/06(280405) **www.e-t-a.com**
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →