11-BG00-31-D-024
Safety Relay, 24 VDC, 3PST-NO, SPST-NC, DIN Rail, Panel, 10 A, Screw
- Manufacturer: BANNER ENGINEERING
- Product type: Safety Relays
- SVHC: No SVHC (15-Jan-2018)
- IP Rating: IP20
- Coil Voltage: 24VDC
- Product Range: -
- Relay Mounting: DIN Rail, Panel
- Contact Current: 10A
- Relay Terminals: Screw
- Contact Material: -
- Contact Configuration: 3PST-NO, SPST-NC
- Contact Voltage AC Nom: 690V
- Contact Voltage DC Nom: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 101.8 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Mechanically Linked Contactors** _Provide additional 10 or 18 amps carrying capability to any safety system_ ## ~~**Features**~~ - For use with a safety device (e.g. a safety light screen or safety module/controller) which has solid state or hard contact outputs - Provides three normally open safety contacts and one normally closed monitoring contact for any safety system - Auxiliary contact blocks, either three or four normally open depending on the model, are available - - - 24V dc or 120V ac coil voltage, depending on model - 10 amp or 18 amp contact rating - Generally used in pairs for safety function; normally closed contacts used for the monitoring function of a safety system (e.g. External Device Monitoring EDM) - - Standard DIN rail or flush-mounting ## ~~**Models**~~ |**Model**|**Coil Voltage***|**Safety Contacts**|**Monitoring Contacts**|**Contact Rating**| |---|---|---|---|---| |**11-BG00-31-A12060**|120V ac|3 normally open|1 normally closed|10 amps(thermal)| |**11-BG00-31-D024**|24V dc|||10 amps(thermal)| |**BF1801A-12060**|120V ac|||18 amps**(inductive)| |**BF1801L-024**|24V dc|||18 amps**(inductive)| * One Arc Suppressor is needed for each relay across the coil (see page 4) - ** NC contact is rated at 10 amps ## ~~**Overview**~~ Contactors can take many forms, thought the most common in a safety circuit are forced-guided, mechanically linked relays. The mechanical linkage between the contacts allows the device to be monitored by an external monitoring circuit for certain failures. Depending on the application, the use of contactors can facilitate controlling voltage and current that differs from the output signal switching device (OSSD) outputs of the safety devices. Contacts can also be used to control an additional number of hazards by creating multiple safety stop circuits. **WARNING . . . These contactors are not point-of-operation guarding devices, as defined by OSHA regulations.** It is necessary to install point-of-operation guarding devices, such as safety light screens and/or hard guards, to protect personnel from hazardous machinery. **Failure to install point-of-operation guards on hazardous machinery could lead to serious injury or death.** Printed in USA 02/09 P/N 111881 rev. A ## **Mechanically Linked Contactors** ## **Important... read this before proceeding!** **The user is responsible for satisfying all local, state, and national laws** , rules, codes, and regulations relating to the use of this product and its application. Banner Engineering Corp. has made very effort to provide complete application, installation, operation, and maintenance instructions. Please direct any questions regarding the use or installation of this product to the factory applications department at the telephone numbers or address shown on the back cover. **The user is responsible** for making sure that all machine operators, maintenance personnel, electricians, and supervisors are thoroughly familiar with and understand all instructions regarding the installation, maintenance, and use of this product, and with the machinery it controls. The user and any personnel involved with the installation and use of this product must be thoroughly familiar with all applicable standards, some of which are listed below. Banner Engineering Corp. makes no claim regarding a specific recommendation of any organization, the accuracy or effectiveness of any information provided, or the appropriateness of the provided information for a specific application. ## **Applicable U.S. Standards** ## **Applicable International Standards** **ANSI B11** Standards for Machine Tools **ISO 12100-1 (EN292-1)** Safety of Machinery – Basic Concepts, General Principles for Design, Part 1: Basic Terminology, Methodology Contact: Safety Director, AMT – The Associations for Manufacturing Technology, 7901 Westpark Drive, McLean, VA 22102, Tel: 703-893-2900 **ISO 12100-2 (EN 292-2)** Safety of Machinery – Basic Concepts, General Principles for Design, Part 2: Technical Principles and Specifications - **IEC/EN60204-1** Electrical Equipment of Machines: Part 1: General Requirements. (Also request a type “C” standard for specific machinery.) **NFPA79** Electrical Standard for Industrial Machinery Contact: National Fire Protection Association, 1 Batterymarch Park, P.O. Box 9101, Quincy, MA 02269-9101, Tel: 800-344-3555 **ISO 13849-1 (EN954-1)** Safety of Machinery – Related Parts of Control Systems: Part 1 General Principles for Design **ISO 13856-1 (EN1760-1)** Safety of Machinery – Pressure-Sensitive Protective Devices: General Principles for Design and Testing **ANSI/RIA R15.06** Safety Requirements for Industrial Robots and Robot Systems Contact: Robotic Industries Association, 900 Victors Way, P.O. Box 3724, Ann Arbor, MI 48106, Tel: 734-994-6088 Contact: Global Engineering Documents, 15 Inverness Way East, Englewood, CO 80112-5704, Tel: 800-854-7179 ## ~~**Mechanical Installation**~~ Flush-mount (clearance for M3 hardware) or mount to 35 mm DIN rail. Contactor must be mounted inside an enclosure rated NEMA3, IEC (IP54) or better. ## ~~**Electrical Installation**~~ As the Contactors can interface to a multitude of machine control configurations, it is not possible to give exact wiring instructions for the output contacts. The following guidelines are general in nature. Installation and wiring must be made by qualified personnel and must comply with the NEC (National Electrical Code), ANSI NFPA79 or IEC 60204-1, and all applicable local standards and codes. Since the Contactors can switch high levels of energy, the user must consider and prevent the possibility of arc flash hazards. Arc flash can release dangerous amounts of heat and blast energy. When using low-voltage equipment (240V or less) being fed by small transformers (125kVA or less) the potential hazard is small, but the risk increases with higher voltage or larger transformers. The Contactors may be required to be located in such a manner that minimizes arc flash hazards. Refer to ANSI NFPA70E for more information. To satisfy the requirements of Category 3 or 4 of ISO 13849-1 (EN 954-1) and Control Reliability (OSHA/ANSI), one normally closed mechanically linked (forced guided) contact from each Contactor must be monitored by the External Device Monitoring (EDM) function of the safety device. When redundant contactors are used, this will enable the detection of a failure, such as a welded contact, and prevent successive machine cycles. **It is the user’s responsibility to monitor the contactors’ normally closed contacts, to ensure that any single failure will not result in a hazardous condition and will prevent a successive machine cycle.** ## **WARNING . . . Shock Hazard** **Always disconnect all power before making any wire connections.** Electrical installation and wiring must be made by qualified personnel and must comply with the NEC (National Electrical Code) and ANSI NFPA70E, ANSI NFPA79 or IEC 60204-1, and all applicable local standards and codes. ## **WARNING . . . Not for Use As a Stand-Alone Safety Device** **1. DO NOT connect E-stop switches, 2-hand-control switches, safety interlock switches, or similar devices directly to an individual contactor.** **2. ALWAYS connect the NC contact of these contactors to the monitoring input of the EDM that controls it.** This Contactor does not have the circuitry required to perform a self-check. A single fault inside the unit or in external devices (like switches or E-stop buttons) can go undetected and create an unsafe condition. **Failure to properly connect these contactors to a Safety Device could result in serious injury or death.** ~~**Banner Engineering Corp.** • Minneapolis, MN U.S.A~~ www.bannerengineering.com • Tel: 763.544.3164 **2** P/N 111881 rev. A ## **Mechanically Linked Contactors** ## ~~**Electrical Installation**~~ **==> picture [158 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> 11-BG00-31-...Models<br>A1 13 21 33 43<br>A2 14 22 34 44<br>**----- End of picture text -----**<br> **==> picture [146 x 130] intentionally omitted <==** **----- Start of picture text -----**<br> BF1801-...Models<br>L1 L2 L3<br>A1 1 3 5 21<br>A2 2 4 6 22<br>T1 T2 T3<br>**----- End of picture text -----**<br> ## ~~**Specifcations**~~ **==> picture [525 x 471] intentionally omitted <==** **----- Start of picture text -----**<br> 11-BG00-31-D024 BF1801L-024 11-BG00-31-A12060 BF1801A-12060<br>Input Voltage and Current 24V dc 120V ac<br>Operating Voltage Limits<br> Pick-up: (0.8-1.10) x Un<br>Drop-out: (0.2-0.55) x Un<br>Average Coil In-Rush 3.2 W 9 W 25 VA 70 VA<br>Consumption<br>at 20 ° C 60 Hz Holding 3.2 W 9 W 3 VA 6.5 VA<br>Output Configuration Number of N.O. Contacts: 3<br>Number of N.C. Contacts: 1<br>Output Max. Voltage 690V<br>Ratings Max. Current 10 A (resistive) 18 A (≤ 440 V; 55°C) 10 A (resistive) 18 A (≤ 440 V; 55°C)<br>Mechanical Life 20,000,000 operations<br>Conventional Free Air<br>Thermal Current Ith (≤ 40 ° C) 10 A 25 A 10 A 25 A<br>Rated Insulation Voltage (Ui) 690V<br>Frequency Limit 25-40 Hz (derating for use at 61-400 Hz)<br>Terminal Tightening Torque 0.8-1 Nm (0.59-0.74 lb/ft)<br>Min./Max.<br>Max. Wire Gauge (for 1 or 2 18-12 AWG<br>Wires) Flexible w/o Ferrule: 0.75-2.5 mm [2]<br>Flexible w/ Ferrule: 2 x 1 or 1 x 2.5 mm [2]<br>Output Closing NO 18-25 42-58 12-21 8-24<br>Response Opening NO 2-3 7-13 9-18 10-20<br>Time (ms)<br>Closing NC 3-5 11-17 17-26 17-30<br>Opening NC 11-17 32-42 7-17 7-18<br>Environmental Rating Rated NEMA 1, IEC IP20<br>Contactors must be installed inside an enclosure rated NEMA 3 (IEC IP54) or better<br>Mounting Mounts to standard 35 mm DIN-rail track or flush mount (4 screws)<br>Operating Conditions Temperature: -40° to +60°C (-40° to +122°F) operating; -55° to +70°C (-40° to +122°F) storage<br>Max. Relative Humidity: 90% @ 50°C (non-condensing)<br>Certifications<br>US<br>LISTED 48D6<br>IND. COMT. EQ.<br>Application Notes There are no adjustments and no user-serviceable parts<br>**----- End of picture text -----**<br> ~~**Banner Engineering Corp.** • Minneapolis, MN U.S.A~~ www.bannerengineering.com • Tel: 763.544.3164 P/N 111881 rev. A **3** ## **Mechanically Linked Contactors** **==> picture [522 x 421] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal Wiring Diagrams Dimensions<br>11-BG00-31-...Models<br>11-BG00-31-...Models BF1801-...Models<br>57.0 [2.24"] 44.0 [1.73"]<br>13 21 33 43 A1 A2 34.9 [1.37"]<br>a n 7 oo<br>NO NC NO NO A1+<br>1NO 3NO 5NO 21NC<br>ooo L1 L2 L3 | " [sege9,<br>58.0 [2.28"] 50.0 [1.97"]<br>BG0031x<br>_) om 8888 BF1801x ~ i<br>Oo O 4.5 [0.18"] ee 5.5 [0.21"]<br>BF1801-...Models<br>45.0 [1.77"]<br>14 22 34 44 A2- 80.7 [3.18"] AC Coil 35.0 [1.38"]<br>98.5 [3.88"] DC Coil<br>NO NC NO NO<br>= Lt<br>ie I) Le | ©.<br>2NO 4NO 6NO 22NC : co |) 81.0 [3.19"] 71.0 [2.79"]<br>T1 T2 T3<br>A1 A2<br>TT ome)<br>Accessories and Replacement Parts<br>Auxiliary Contacts for Mechanically Linked Contactors<br>Adds contacts to mechanically linked contactors.<br>DQ Models Safety Contacts Mechanically Linked Used with<br>11-BGX10-40 No<br>4 normally open (N.O.) 11-BG Series<br>(not shown) (Aux. only)<br>11-G484-30<br>3 normally open (N.O.) Yes BF Series<br>(shown)<br>8 QO<br>**----- End of picture text -----**<br> ## **Suppressors for Mechanically Linked Contactors** Extends the life of the actuating device, such as a screen or control module, that uses a mechanically linked contactor. ~~ee~~ **Models Voltage Used with 11-BGX77-048** 48V dc 11-BG00-31-D024 **11-BGX77-240** 125-240V ac 11-BG00-31-A12060 ~~————~~ **11-G318-48** 48V dc BF1801L-024 ~~ep~~ **BFX77-240** 125-240V ac BF1801A-12060 ~~Mee~~ **WARRANTY:** Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. P/N 111881 rev. A Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →