Image not available
Illustrative purposes only
1-1393223-4
Power Relay, MSR V23061 Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TE CONNECTIVITY / PARTNER STOCK
- Product type: Power Relays
- SVHC: No SVHC (07-Nov-2024)
- Product Range: MSR V23061 Series
| Delivery and price | |
|---|---|
| Units per pack | 120 |
| Price | 3.65 € |
| Current stock | 200+ |
| Lead time | 30 days |
Miniature Power Relay MSR V23061 ## **PCB relay for DC voltage, neutral, monostable** ## **Features** - G Used as a switching element for electrical separation between low-power control circuits and power load circuits - G With 8 mm clearance and creepage distances up to 8 A continuous current (UL, CSA: 10 A) **==> picture [33 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> ECR0001-B<br>**----- End of picture text -----**<br> - G Low self-heating thanks to low power consumption - G High packing densities possible - G Suitable for fully automated processing **==> picture [47 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Approx. 1:1 scale<br>**----- End of picture text -----**<br> - G General-purpose relay for instrumentation and control - G Mechanical and electrical characteristics comply with the “Rules for electrical relays in power installations” (VDE 0435/9.72) - G Used for safe electrical insulation in the following applications - power installations (VDE 0160) - open and closed-loop control equipment for domestic use (VDE 0631) - electrical equipment for domestic use (VDE 0700) ## **Design** - Size I with 1 make contact or Size II with 1 changeover contact - For printed circuit assembling - Immersion cleanable or suitable for soldering lines - electronic equipment for domestic use (VDE 0860); on request ## **Approvals** ## **Typical applications** - G Interface technology - G Heating control systems - G Temperature controllers - G Timer switches - G Household equipment |VDE<br>LS|VDE<br>LS|VDE|Mark of conformity|**3919**<br>xs| |---|---|---|---|---| |8||SEV|89.1 02176.02|| |@||CSA|File LR 45064-7|| |‘A||UL|File E 48393|| |©||SEMKO|9049293|| |I)|I)|SETI|142344-01|| Siemens AG 2 Miniature Power Relay MSR ## **Dimensional drawing** (in mm) ## **Size II** with 1 changeover contact **==> picture [181 x 105] intentionally omitted <==** ## **Size I** with 1 make contact **==> picture [180 x 105] intentionally omitted <==** ## **Mounting hole layout** View on the terminals - 1 changeover contact **==> picture [130 x 81] intentionally omitted <==** ## 1 make contact **==> picture [126 x 81] intentionally omitted <==** **Terminal assignment** View on the terminals 1 changeover contact **==> picture [95 x 56] intentionally omitted <==** ## 1 make contact **==> picture [91 x 42] intentionally omitted <==** Siemens AG 3 ## Miniature Power Relay MSR |**Contact data**|**Contact data**|**Contact data**|**Contact data**|**Contact data**| |---|---|---|---|---| |Contact category III according to VDE 0435 Part 120/10.81, Appendix B||||| |Ordering code, block 3|A301/A302|A401/A402|A501/A502|A601/A602| |Number of contacts and type|1 changeover contact or 1 make contact|||| |Contact assembly|Single contacts|||| |Contact material|AgSnO2|AgCdO|AgNi 0,15<br>gold-flashed|AgCdO<br>gold-plated| |Max. continuous current at<br>max. ambient temperature|8 A|||| |Inrush current<br>(max. 4 s at 10% duty cycle)|15 A|||| |Maximum switching voltage|440 V~<br>300 V–|||| |Maximum switching capacity<br>AC voltage<br>DC voltage|2000 VA<br>See load limit curve|||| |Recommended for loads >|500 mA, 12 V~/V–|500 mA, 12 V~|1 mA, 6 V–|µW| |Contact resistance<br>(initial value)/measuring<br>current/driver voltage|≤100 mΩ/1 A/24 V<br>≤|100 mΩ/1 A/24 V<br>|≤100 mΩ/100 mA/6 V|≤30 mΩ/100 mA/6 V| **Note:** Inrush currents up to 80 A possible on request. ## **Load limit curve** **==> picture [314 x 213] intentionally omitted <==** I = switching current U = switching voltage Definition of the load limit curve: In 1000 operations there must be no arc with a burning time > 10 ms. Siemens AG 4 Miniature Power Relay MSR |**Coil data**|**Coil data**| |---|---| |Nominal voltages|From 3 V– to 60 V–<br>Special voltages on request| |Nominalpower consumption, typ., at 20 °C|210 ... 270 mW| |Pull-in power, at 20 °C|100 ... 120 mW| |Operating range/class of energizing voltage according to DIN IEC 255<br>Part 1-00 or VDE 0435 Part 201|<br>2/b| |Minimum release voltage|10 % of nominal voltage| |**Coil versions**|**Coil versions**|**Coil versions**|**Coil versions**|**Coil versions**|**Coil versions**|**Coil versions**|**Coil versions**|**Coil versions**|**Coil versions**|**Coil versions**|**Coil versions**| |---|---|---|---|---|---|---|---|---|---|---|---| |Nominal voltage<br>Unom<br>V–|Operate voltage<br>at 20 °C<br>Uop cold<br>V–|Operating voltage range<br>at 20 °C<br>Oper. voltage UI<br>V–<br>Max. voltage UII<br>V–||||Resistance<br>at 20 °C<br>Ω|||Number of coil,<br>ordering code,<br>block 2||| |3|2.1|2.1|7.5|||40 ±<br>4|||001||| |5|3.4|3.6|12.5|||118 ±<br>12|||002||| |6|4.1|4.3|15.0|||165 ±<br>17|||003||| |9|6.1|6.4|22.0|||365 ±<br>37|||004||| |12|8.2|8.5|30.0|||650 ±<br>65|||005||| |18|12.2|12.8|45.0|||1455 ±<br>145|||006||| |24|16.3|17.2|56.0|||2270 ±<br>230|||007||| |36|24.5|25.4|88.0|||5640 ±<br>565|||008||| |48|32.6|34.5|110.0|||8790 ±<br>880|||009||| |60|40.8|42.8|142.0|||15265 ±<br>2290|||010||| |Other coil versions available on request<br>Uop cold=<br>Operate voltage at 20 °C without pre-energizing<br>the coil<br>UI<br>=<br>Operate voltage at 20 °C after pre-energizing with<br>Unomwithout contact current<br>UII<br>=<br>Maximum continuous voltage at 20 °C for<br>Tc max= 115 °C without contact load<br>Operating voltage limits UIand UIIdepend on temperature and<br>can be calculated by:<br>UI tamb=<br>kI· UI 20 °Cand UII ta =<br>kII· UII 20 °C<br>tamb<br>=<br>Ambient temperature<br>UI tamb=<br>Minimum voltage at ambient temperature tamb<br>UII tamb=<br>Maximum voltage at ambient temperature tamb<br>kIa. kII=<br>Factors (dependent on temperature), see diagram<br>Tc max =<br>Maximum coil temperature|||||||||||| |||||~~k~~I<br>kII<br>Ambient temerature t|||||||| ||||||||||kII||| ||||||||||||| |||||pamb|||||||| Siemens AG 5 ## Miniature Power Relay MSR |**General data**|||||| |---|---|---|---|---|---| |Operate time at Unomand 20 °C, typ.|6 ms||||| |Release time without/with parallel diode, typ.|2.5 ms / 10 ms||||| |Bounce time, make/break contact typ.|0.5 ms / 4 ms||||| |Maximum switching rate without load|1200 min-1||||| |Maximum switching rate with rated load|30 min-1||||| |Ambient temperature range according to<br>DIN IEC 255 Part 1-00 or VDE 0435 Part 201|-40 °C ... 70 °C||||| |Thermal resistance|75 K/W||||| |Coil temp. rise due to rated contact current|Approx. 7 K||||| |Maximum permissible coil temperature|115 °C||||| |Protection class according to<br>DIN 40050/IEC 529|Immersion cleanable IP 67<br>Suitable for solderinglines IP 50||||| |Electrical endurance|Load||Contact<br>material|Contact|Endurance, typ.,<br>operations| ||Rated load 8 A, 230 V~||AgCdO|Make|1 x 105| ||Motor load 230 V~<br>Inrush current 18 A cosϕ0.5<br>Rated current 1.8 A cosϕ 0.5||AgCdO|Make|4 x 105| ||AC15 3A according to<br>VDE 660 / IEC 947, 230 V~||AgSnO2|Make|2 x 105| ||Valve load 0.1 A, 230 V~||AgCdO|Make|1 x 106| ||Hydraulic valves 2 A, 24 V–||AgNi 0,15|Make|1 x 10 6| ||Lamp load 6 A, 230 V~||AgSnO2|Make|1 x 104| |Mechanical endurance|Approx. 1 x 107operations||||| |Flammability according to UL 94|V-0||||| |Solder bath temperature/max. duration|260 °C / 5 s||||| |Mounting position|Any||||| |Processing information|Wherever possible, ultrasonic cleaning should not be used; if absolutely ne-<br>cessary, then only after consultation with the manufacturer.||||| |Weight|11g||||| ||||||| |**Insulation**|||||| |According to IEC 664/VDE 110 (1/89):<br>rated voltage<br>pollution severity<br>overvoltage category||250 V<br>3<br>III|||| |According to VDE 0110 (2/79):<br>insulationgroup/rated voltage||C/250<br>B/380|||| |Dielectric test voltage, contact – coil(1 min)||4000 V~rms|||| |Surge voltage, contact – coil (1.2 – 50 µs)||8000 V|||| |Dielectric test voltage between open contacts|(1 min)|1000 V~rms|||| |Clearance/creepage distances||8 mm / 8 mm|||| |Insulation resistance at 500 V (initial value)||> 105MΩ|||| |Tracking resistance of the fundamental frame|according to DIN IEC 112|CTI 250|||| Siemens AG 6 Miniature Power Relay MSR ## **Ordering code** |**Ordering code**|**Ordering code**|**Ordering code**|||||||||||||||||||||||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| ||||Data position|1||2<br>3<br>4<br>5<br>6<br>Block 1|||||||||||7<br>8<br>9<br>10 11<br>12 13 14 15<br>Block 2<br>Block 3||||||||||||||||||| |||||V||2||3||0||6||1||||||||||||||A|||||||| ||||||||||||||||||||||||||||||||||||| ||||||||||||||||||||||||||||||||||||| ||||||||||||||||||||||||||||||||||||| |Identifier for<br>Miniature Power Rel<br>Size<br>A = Size I, with 1 ma<br>B = Size II, with 1 ch<br>Version<br>1 = immersion clean<br>2 = suitable for sold<br>Coil number<br>001 = 3 V– nomina<br>002 = 5 V–<br>003 = 6 V–<br>004 = 9 V–<br>005 = 12 V–<br>006 = 18 V–<br>007 = 24 V–<br>008 = 36 V–<br>009 = 48 V–<br>010 = 60 V–<br>Contact pile-up<br>A = Standard<br>Contact material<br>3 = AgSnO2<br>4 = AgCdO<br>5 = AgNi 0,15, gold-<br>6 = AgCdO, hard go<br>Ctt|wer Rel|ay MSR|||||||||||||||||||||||||||||||||| ||||||||||||||||||||||||||||||||||||| ||th 1 ma<br>ith 1 ch<br>n clean<br>or sold|ke contact<br>angeover contact|||||||||||||||||||||||||||||||||| |||able<br>ering lines|||||||||||||||||||||||||||||||||| |||l voltage|||||||||||||||||||||||||||||||||| ||||||||||||||||||||||||||||||||||||| |||flashed<br>ld-plated<br>t|||||||||||||||||||||||||||||||||| Contact arrangement 01 = 1 changeover contact 02 = 1 make contact Ordering example: V23061-B1005-A401 MSR relay with 1 changeover contact (Size II), coil 12 V nominal voltage, contact material silver cadmium oxide (AgCdO) Siemens AG 7
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →