093.16
Relay Accessory, Jumper, 93 Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: FINDER
- Product type: Other Relay Accessories
- Accessory Type:Jumper; For Use With:-; Product Range:39 Series; SVHC:No SVHC (15-Jan-2019)
- SVHC: No SVHC (04-Feb-2026)
- For Use With: -
- Product Range: 93 Series
- Accessory Type: Jumper
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 2.76 € |
| Current stock | 10+ |
| Lead time | 30 days |
39 SERIES
B
## _MasterINTERFACE_ 39 Series - Relay interface modules
## Common features
- Space saving 6.2 mm wide
- Connections for 16-way jumper link
- Integral coil indication and protection circuit • Secure retention and easy ejection by plastic clip
- • Dual screw head (blade+cross) terminals and Push-in terminals versions
EMR SSR Electromechanical Relays Solid State Relays
- 1 solid state output (options 0.1 A 48 V DC, 2 A 24 V DC, 2 A 240 V AC)
- 1 CO 6 A 250 V AC
- High switching capability
- Silent, high speed switching, long electrical life
- 35 mm rail mounting (EN 60715)
## _MasterBASIC_
## 39.11/39.01 39.10/39.00
- For general use in any type of system
- EMR: 6 to 24 and 125 V AC/DC, 230 V AC upply
- SSR: 6 to 24 V DC, 125 V AC/DC, 230 V AC supply
- Screw terminal and Push-in terminal
## _MasterPLUS_
Page 5
Page 4
39.31 - 39.31.3/39.61 - 39.61.3 39.30 - 39.30.3/39.60 - 39.60.3
• Accepts the output fuse module, for the easy and space efficient protection of output circuits
- EMR: 6 to 125 V AC/DC, 125 and 220 V DC, 230 V AC and 24...240 V AC/DC supply
- SSR: 24 - 125 V AC/DC, 6 to 220 V DC, 230 V AC and 24...240 V AC/DC supply
- Special 125 V AC/DC and 230 V AC leakage current suppression types (39.31.3, 39.61.3 EMR and 39.30.3, 39.60.3 SSR)
- Screw terminal and Push-in terminal
## _MasterINPUT_
Page 6 Page 7
## 39.41/39.71 39.40/39.70
- Jumper link option for the quick and easy distribution of supply voltage to proximity switches and similar input devices
- EMR: 6 to 24 V and 125 V AC/DC, 230 V AC supply
- SSR: 6 - 24 V DC, 24 - 125 V AC/DC, 230 V AC supply
- Screw terminal and Push-in terminal
## _MasterOUTPUT_
Page 8
39.21/39.51 39.20/39.50
Page 9
- Jumper link option for the quick and easy distribution of supply voltage to output side and its connection to electromagnetic valves and similar output devices
- EMR: 6 to 24 V and 125 V AC/DC, 230 V AC supply
- SSR: 6 to 24 V DC, 125 V AC/DC, 230 V AC supply
- Screw terminal and Push-in terminal
## _MasterTIMER_
Page 10
39.81/ 39.91 39.80/39.90
Page 11
- Timer adjustment via top mounted rotary knob accessible after assembly
- Control signal terminal
- DIP-switch for selection of 4 time scales and 8 functions
- Output with fuse module option
- EMR and SSR: 12 to 24 V AC/DC supply
- Screw terminal and Push-in terminal
Page 12
Page 13
39 SERIE S
## Typical Applications
B
## _MasterBASIC_
- 39.11 - 39.10 - 39.01 - 39.00 • For general interface use in any type of system and application.
- Can be used for input interface applications between auxiliary contacts, sensors etc. and controllers, PLCs’ or motors. Or for output interface between PLC’s controllers and relays, solenoids etc.
## _MasterPLUS_
39.31 - 39.30 - 39.31.3 - 39.30.3 - 39.61 - 39.60 - 39.61.3 - 39.60.3
- This special version provides extra protection for the output circuit thanks to the replaceable fuse module.
- For general interface use in any type of system and application.
- Can be used for input interface applications between auxiliary contacts, sensors etc. and controllers, PLCs’ or motors. Or for output interface between PLC’s controllers and relays, solenoids etc.
**==> picture [464 x 615] intentionally omitted <==**
**----- Start of picture text -----**<br>
Output devices Output devices<br>be be<br>®<br>TEED ® ghee<br>Fuse module<br>093.63<br>PaWd de Al A2 | FGUh ec Al A2 l<br>| Pd |<br>l |<br>ll<br>PLC - Output o PLC - Output<br>Ai<br>PLC - Input +) PLC - Input<br>Fuse module<br>11(13) 11(13)<br>093.63<br>lofofofo lofofofo<br>' my ° SG tty )<br>e e<br>e c= e<br>ll ° Wa e<br>: Sill :<br>Input devices Input devices I-2015, www.findernet.com<br>**----- End of picture text -----**<br>
2
39 SERIES
B
## Typical Applications
## _MasterINPUT_
39.41 - 39.40 - 39.71 - 39.70
- These models allow the full termination of input device to the interface without the need for additional terminals - saving component cost, time and panel space.
- Quick and easy distribution of supply voltage through the jumper link on the Bus-Bar (BB) connection.
- Ideal for interface applications between the auxiliary contacts, sensors, limit switches and Controllers or PLC’s.
## _MasterOUTPUT_
## _MasterTIMER_
39.21 - 39.20 - 39.51 - 39.50
39.81 - 39.80 - 39.91 - 39.90
- These models allow the full termination of • Slim and Multifunction Timed Interface output device to the interface without the modules. need for additional terminals - saving component cost, time and panel space.
- Quick and easy distribution of supply voltage through the jumper link on the Bus-Bar (BB) connection.
- Ideal for interface applications between the PLC’s or Controllers and output devices such as electomagnetic valves or motors etc..
**==> picture [438 x 366] intentionally omitted <==**
**----- Start of picture text -----**<br>
Output devices Output devices<br>al s aa<br>in a<br>| el<br>Fuse module<br>093.63<br>aaa AD add AT<br>aad A2 [[ aeiat oT A2 I|<br>I | qyo]I<br>So PLC - Output eS PLC - Output<br>Ono | On<br>hy) Ht)<br>PLC - Input PLC - Input<br>**----- End of picture text -----**<br>
**==> picture [46 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input devices<br>**----- End of picture text -----**<br>
**==> picture [46 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input devices<br>**----- End of picture text -----**<br>
3
39 SERIE S 39 Series - Relay interface modules 0.1 - 2 - 6 A
## _MasterBASIC_ - EMR
## 39.11/39.01
## Features
1 Pole interface module, 6.2 mm wide, ideal for PLC and electronic systems
B
- Common connection possible with optional jumper links (terminals A1, A2 and 11)
- UL Listing (certain relay/socket combinations)
- 6 A electromechanical relay
- • 6 to 24 and 125 V AC/DC and 230 V AC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
39.11 39.01 Screw terminal Push-in terminal
For outline drawing see page 20, 21
|Contact specification||||||
|---|---|---|---|---|---|
|Contact configuration||||1 CO (SPDT)||
|Rated current/Maximumpeak current|||A|6/10||
|Rated voltage/Maximum switchingvoltage||V AC|V AC|250/400||
|Rated load AC1|||VA|1,500||
|Rated load AC15 (230 V AC)|||VA|300||
|Singlephase motor rating(230 V AC)|||kW|0.185||
|Breaking capacity DC1: 30/110/220 V|||A|6/0.2/0.12||
|Minimum switching load|mW (V/mA)|mW (V/mA)||500 (12/10)||
|Standard contact material||||AgNi||
|Supply specification||||||
|Nominal voltage (UN)|V AC/DC|||6 - 12 - 24 - 110...125||
||V AC (50/60 Hz)||V AC (50/60 Hz)|220...240<br>V AC (50/60 Hz)||
|Rated power|VA (50 Hz)/W|VA (50 Hz)/W||See page 16||
|Operating range||||(0.8...1.1)UN||
|Holding voltage||||0.6 UN||
|Must drop-out voltage||||0.1 UN||
|Technical data||||(0.8...1.2)UN||
|Mechanical life AC/DC||cycles||10 · 10<br>6||
|Electrical life at rated load AC1||cycles||60 · 10<br>3||
|Operate/release time|||ms|5/6||
|Insulation between coil and contacts (1.2/50 μs)<br>Dielectric strength between open contacts<br>Ambient temperature range<br>Protection category<br>Approvals relay(according to type)<br>V AC|||kV<br>V AC<br>°C|6 (8 mm)<br>1,000<br>–40…+70<br>IP 20<br>C€@EAL&<br>Rina|Adis|
4
39 39 Series - Relay interface modules 0.1 - 2 - 6 A SERIES
B
## _MasterBASIC_ - SSR
## SS
## Features
1 Pole interface module, 6.2 mm wide, ideal for PLC and electronic systems
- Common connection possible with optional jumper links (terminals A1, A2 and 13+)
- UL Listing (certain relay/socket combinations)
- 0.1 or 2 A solid state relay
- 6 to 24 V DC, 125 V AC/DC and 230 V AC supply
- Screw terminal and push-in terminal
- • 35 mm rail (EN 60715) mounting
39.10 39.00 Screw terminal Push-in terminal
|For outline drawing see page 20, 21|For outline drawing see page 20, 21|||||||
|---|---|---|---|---|---|---|---|
|Output specification (SSR)|||39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240|39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240|39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240||39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240|
|Contact configuration|||1 NO (SPST-NO)|||||
|Rated current/Maximum peak current (10 ms)||A|2/20 DC 0.1/0.5 DC 2/40 AC<br>A|2/20 DC 0.1/0.5 DC 2/40 AC|2/20 DC 0.1/0.5 DC 2/40 AC|2/20 DC 0.1/0.5 DC 2/40 AC|2/20 DC 0.1/0.5 DC 2/40 AC|
|Rated voltage/Maximum blocking voltage|Rated voltage/Maximum blocking voltage|V|24/33 DC 48/60 DC 240/— AC|24/33 DC 48/60 DC 240/— AC|24/33 DC 48/60 DC 240/— AC|24/33 DC 48/60 DC 240/— AC|24/33 DC 48/60 DC 240/— AC|
|Switching voltage range||V|(1.5…24) DC (1.5…48) DC (12…275) AC|(1.5…24) DC (1.5…48) DC (12…275) AC|(1.5…24) DC (1.5…48) DC (12…275) AC||(1.5…24) DC (1.5…48) DC (12…275) AC|
|Repetitive peak off-state voltage||Vpk|— — 600|— — 600|— — 600|— — 600|— — 600|
|Minimum switching current||mA|1 0.05 22|1 0.05 22|1 0.05 22|1 0.05 22|1 0.05 22|
|Max. “OFF-state” leakage current||mA|0.001 0.001 1.5|0.001 0.001 1.5|0.001 0.001 1.5|0.001 0.001 1.5|0.001 0.001 1.5|
|Max. “ON-state” voltage drop||V|0.12 1 1.6|0.12 1 1.6|0.12 1 1.6|0.12 1 1.6|0.12 1 1.6|
|Supply specification||||||||
|Nominal voltage (UN)|V AC/DC|V AC/DC|||110...125|||
||V AC(50/60 Hz)||||220...240|||
|||V DC|||6 - 12 - 24|||
|Rated power|VA(50 Hz|50 Hz)/W|||See page 17|||
|Operating range|||||(0.8…1.1) UN|||
|Must drop-out voltage|||||0.1 UN|||
|Technical data||||||||
|Operate/release time||ms|0.2/0.6 0.04/0.11 12/12|0.2/0.6 0.04/0.11 12/12|0.2/0.6 0.04/0.11 12/12|0.2/0.6 0.04/0.11 12/12|0.2/0.6 0.04/0.11 12/12|
|Dielectric strength between input/output||V AC|2,500|2,500|2,500|||
|Ambient temperature range||°C|–20…+55|–20…+55|–20…+55|||
|Protection category|||IP20|IP20|IP20|||
|Approvals relay(according to type)|||CE|CE|ce<br>FAL|Ay<br>CALs|Ay<br>CALs|
5
39 SERIE S
39 Series - Relay interface modules 0.1 - 2 - 6 A
## _MasterPLUS_ - EMR
**==> picture [292 x 16] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.31/39.61 39.31.3/39.61.3 © ©<br>**----- End of picture text -----**<br>
## Features
1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems
- Accepts output fuse module 093.63 (for 5 x 20 mm fuses) for quick and easy load
- B protection, see page 24 • Common connection possible with optional jumper links (terminals A1, A2 and 11)
- UL Listing (certain relay/socket combinations)
- 6 A electromechanical relay
- 6 to 125 V AC/DC, 125 and 220 V DC, 230 V AC, 24...240 V AC/DC supply
- Screw terminal and push-in terminal
- 6 A electromechanical relay
- Leakage current suppression version, 125 V AC/DC and 230 V AC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
39.31 / 39.31.3 39.61 / 39.61.3 Screw terminal Push-in terminal
**==> picture [38 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse module<br>093.63<br>**----- End of picture text -----**<br>
For outline drawing see page 20, 21
|Contact specification|||||||
|---|---|---|---|---|---|---|
|Contact configuration||||1 CO (SPDT) 1 CO (SPDT)|1 CO (SPDT) 1 CO (SPDT)||
|Rated current/Maximumpeak current|||A|6/10 6/10|6/10 6/10||
|Rated voltage/Maximum switching voltage||V AC|V AC|250/400 250/400|250/400 250/400||
|Rated load AC1|||VA|1,500 1,500<br>VA|1,500 1,500||
|Rated load AC15 (230 V AC)|||VA|300 300|300 300||
|Single phase motor rating (230 V AC)|||kW|0.185 0.185|0.185 0.185||
|Breaking capacity DC1: 30/110/220 V|||A|6/0.2/0.12 6/0.2/0.12|6/0.2/0.12 6/0.2/0.12||
|Minimum switching load|mW (V/mA)|mW (V/mA)||500 (12/10) 500 (12/10)|500 (12/10) 500 (12/10)||
|Standard contact material||||AgNi AgNi|AgNi AgNi||
|Supply specification|||||||
|Nominal voltage (UN)|V AC/DC|||6 - 12 - 24 - 60 - 110…125 - 24...240 110…125|6 - 12 - 24 - 60 - 110…125 - 24...240 110…125||
||V AC (50/60 Hz)||V AC (50/60 Hz)|220...240 220…240<br>V AC (50/60 Hz)|220...240 220…240||
|||V DC|V DC|110…125 - 220 —|110…125 - 220 —||
|Rated power|VA (50 Hz)/W|VA (50 Hz)/W||See page 16 See page 16|See page 16 See page 16||
|Operating range||||(0.8…1.1) UN(0.8…1.1) U|(0.8…1.1) UN||
|Holding voltage||||0.6 UN0.6 U|0.6 UN||
|Must drop-out voltage||||0.1 UN0.3 U|0.3 UN||
|Technical data|||||||
|Mechanical life AC/DC||cycles||10 · 10<br>610 · 10|10 · 10<br>6||
|Electrical life at rated load AC1||cycles||60 · 10<br>360 · 10|60 · 10<br>3||
|Operate/release time|||ms|5/6 5/6|5/6 5/6||
|Insulation between coil and contacts(1.2/50μs)<br>Dielectric strength between open contacts<br>Ambient temperature range<br>Protection category<br>Approvals relay(according to type)<br>V AC|||kV<br>V AC<br>°C|6(8 mm)6(8 mm)<br>1,000 1,000<br>–40…+70 (+55 for 220 V DC) –40…+70<br>IP20 IP20<br>®<br>C€ @ FAL & RINAAs||I-2015, www.findernet.com|
6
39 SERIES
39 Series - Relay interface modules 0.1 - 2 - 6 A
B
## _MasterPLUS_ - SSR
## 39.30/39.60 39.30.3/39.60.3 wed
## Features
1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems
- Accepts output fuse module 093.63 (for 5 x 20 mm fuses) for quick and easy load protection, see page 24
- Common connection possible with optional jumper links (terminals A1, A2 and 13+)
- UL Listing (certain relay/socket combinations)
- 0.1 or 2 A solid state relay
- 24 - 125 V AC/DC, 6 to 220 V DC and 230 V AC, 24...240 V AC/DC supply
- Screw terminal and push-in terminal
- 0.1 or 2 A solid state relay
- Leakage current suppression version, 125 V AC/DC and 230 V AC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
39.30 / 39.30.3 39.60 / 39.60.3 Screw terminal Push-in terminal
**==> picture [148 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
i<br>[a] iiDA 1 [!] Fuse module<br>i a] i oa 093.63<br>**----- End of picture text -----**<br>
For outline drawing see page 20, 21
|Output specification (SSR)|||39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240 39.x0.3.xxx.9024 39.x0.3.xxx.7048 39.x0.3.xxx.8240|39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240 39.x0.3.xxx.9024 39.x0.3.xxx.7048 39.x0.3.xxx.8240|39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240 39.x0.3.xxx.9024 39.x0.3.xxx.7048 39.x0.3.xxx.8240|39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240 39.x0.3.xxx.9024 39.x0.3.xxx.7048 39.x0.3.xxx.8240|39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240 39.x0.3.xxx.9024 39.x0.3.xxx.7048 39.x0.3.xxx.8240|39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240 39.x0.3.xxx.9024 39.x0.3.xxx.7048 39.x0.3.xxx.8240|
|---|---|---|---|---|---|---|---|---|
|Contact configuration|||1 NO (SPST-NO) 1 NO (SPST-NO)|||1 NO (SPST-NO) 1 NO (SPST-NO)|||
|Rated current/Maximum peak current (10 ms)||A|2/20 DC 0.1/0.5 DC 2/40 AC 2/20 DC 0.1/0.5 DC 2/40 AC|2/20 DC 0.1/0.5 DC 2/40 AC 2/20 DC 0.1/0.5 DC 2/40 AC|2/20 DC 0.1/0.5 DC 2/40 AC 2/20 DC 0.1/0.5 DC 2/40 AC|2/20 DC 0.1/0.5 DC 2/40 AC 2/20 DC 0.1/0.5 DC 2/40 AC|2/20 DC 0.1/0.5 DC 2/40 AC 2/20 DC 0.1/0.5 DC 2/40 AC|2/20 DC 0.1/0.5 DC 2/40 AC 2/20 DC 0.1/0.5 DC 2/40 AC|
|Rated voltage/Maximum blocking voltage|Rated voltage/Maximum blocking voltage|V|24/33 DC 48/60 DC 240/— AC 24/33 DC 48/60 DC 240/— AC|24/33 DC 48/60 DC 240/— AC 24/33 DC 48/60 DC 240/— AC|24/33 DC 48/60 DC 240/— AC 24/33 DC 48/60 DC 240/— AC|24/33 DC 48/60 DC 240/— AC 24/33 DC 48/60 DC 240/— AC|24/33 DC 48/60 DC 240/— AC 24/33 DC 48/60 DC 240/— AC|24/33 DC 48/60 DC 240/— AC 24/33 DC 48/60 DC 240/— AC|
|Switching voltage range||V|(1.5…24) DC (1.5…48)DC (12…275) AC (1.5…24) DC (1.5…48)DC (12…275) AC|(1.5…24) DC (1.5…48)DC (12…275) AC (1.5…24) DC (1.5…48)DC (12…275) AC|(1.5…24) DC (1.5…48)DC (12…275) AC (1.5…24) DC (1.5…48)DC (12…275) AC|(1.5…24) DC (1.5…48)DC (12…275) AC (1.5…24) DC (1.5…48)DC (12…275) AC|(1.5…24) DC (1.5…48)DC (12…275) AC (1.5…24) DC (1.5…48)DC (12…275) AC|(1.5…24) DC (1.5…48)DC (12…275) AC (1.5…24) DC (1.5…48)DC (12…275) AC|
|Repetitive peak off-state voltage||Vpk|— — 600 — — 600|— — 600 — — 600|— — 600 — — 600|— — 600 — — 600|— — 600 — — 600|— — 600 — — 600|
|Minimum switching current||mA|1 0.05 22 1 0.05|1 0.05 22 1 0.05|1 0.05 22 1 0.05|1 0.05 22 1 0.05|1 0.05 22 1 0.05 22|22|
|Max. “OFF-state” leakage current||mA|0.001 0.001 1.5 0.001 0.001 1.5|0.001 0.001 1.5 0.001 0.001 1.5|0.001 0.001 1.5 0.001 0.001 1.5|0.001 0.001 1.5 0.001 0.001 1.5|0.001 0.001 1.5 0.001 0.001 1.5|0.001 0.001 1.5 0.001 0.001 1.5|
|Max. “ON-state” voltage drop||V|0.12 1 1.6 0.12 1|0.12 1 1.6 0.12 1|0.12 1 1.6 0.12 1|0.12 1 1.6 0.12 1|0.12 1 1.6 0.12 1 1.6|1.6|
|Supply specification|||||||||
|Nominal voltage (UN)|V AC/DC|V AC/DC|24 - 110…125 - 24...240 110…125|||24 - 110…125 - 24...240 110…125|24 - 110…125 - 24...240 110…125||
||V AC (50/60 Hz)||220...240 220…240|220...240 220…240|220...240 220…240|220...240 220…240|220...240 220…240||
|||V DC|6 - 12 - 24 - 60 - 110…125 - 220 —|6 - 12 - 24 - 60 - 110…125 - 220 —||6 - 12 - 24 - 60 - 110…125 - 220 —|6 - 12 - 24 - 60 - 110…125 - 220 —||
|Rated power|VA (50 Hz)/W|VA (50 Hz)/W|See page 17 See page 17|See page 17 See page 17|See page 17 See page 17|See page 17 See page 17|See page 17 See page 17||
|Operating range|||(0.8…1.1) U|(0.8…1.1) UN|(0.8…1.1) U|(0.8…1.1) U|(0.8…1.1) UN||
|Must drop-out voltage|||0.1 U|0.1 UN0.3 U|0.3 U|0.3 U|0.3 UN||
|Technical data|||||||||
|Operate/release time||ms|0.2/0.6 0.04/0.11 12/12 0.2/0.6 0.04/0.11 12/12|0.2/0.6 0.04/0.11 12/12 0.2/0.6 0.04/0.11 12/12|0.2/0.6 0.04/0.11 12/12 0.2/0.6 0.04/0.11 12/12|0.2/0.6 0.04/0.11 12/12 0.2/0.6 0.04/0.11 12/12|0.2/0.6 0.04/0.11 12/12 0.2/0.6 0.04/0.11 12/12|0.2/0.6 0.04/0.11 12/12 0.2/0.6 0.04/0.11 12/12|
|Dielectric strength between input/output||V AC|2,500 2,500|2,500 2,500|2,500 2,500|2,500 2,500|2,500 2,500||
|Ambient temperature range||°C|–20…+55 –20…+55|–20…+55 –20…+55|–20…+55 –20…+55|–20…+55 –20…+55|–20…+55 –20…+55||
|Protection category|||IP20 IP20|IP20 IP20|IP20 IP20|IP20 IP20|IP20 IP20||
|Approvals relay(according to type)|||||~~CEFL~~|~~&~~<br>~~A~~<br>&Ais|||
7
39 SERIE S 39 Series - Relay interface modules 0.1 - 2 - 6 A
## _MasterINPUT_ - EMR
## 39.41/39.71
## Features
1 Pole interface module, 6.2 mm wide, ideal for PLC and electronic systems
- Jumper link option for the quick and easy distribution of supply voltage to proximity
- B switches and similar input devices (Bus-bar connection BB)
- Gold plated output contact as standard, for better compatibility with low energy PLC inputs
- UL Listing (certain relay/socket combinations)
- 6 A electromechanical relay
- 6 - 12 - 24 - 125 V AC/DC and 230 V AC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
39.41 39.71 Screw terminal Push-in terminal
For outline drawing see page 20, 21
## Contact specification
|Contact specification||||1|
|---|---|---|---|---|
|Contact configuration||||1 CO (SPDT)|
|Rated current/Maximumpeak current||A||6/10|
|Rated voltage/Maximum switchingvoltage||V AC||250/400|
|Rated load AC1||VA||1,500|
|Rated load AC15 (230 V AC)||VA||300|
|Singlephase motor rating(230 V AC)||kW||0.185|
|BreakingcapacityDC1: 30/110/220 V||A||6/0.2/0.12|
|Minimum switching load|mW (V/mA)|||50 (5/2)|
|Standard contact material||||AgNi + Au|
|Supply specification|||||
|Nominal voltage (UN)|V AC/DC||6 - 12 - 24 - 110…125||
||V AC (50/60 Hz)|||220...240|
|Rated power|VA (50 Hz)/W|||See page 16|
|Operating range||||(0.8…1.1) UN|
|Holding voltage||||0.6 UN|
|Must drop-out voltage||||0.1 UN|
|Technical data|||||
|Mechanical life AC/DC||cycles||10 · 10<br>6|
|Electrical life at rated load AC1||cycles||60 · 10<br>3|
|Operate/release time||ms||5/6|
|Insulation between coil and contacts (1.2/50 μs)<br>Dielectric strength between open contacts<br>Ambient temperature range<br>Protection category<br>Approvals relay(according to type)||kV<br>V AC<br>°C|C€@FAL|6 (8 mm)<br>1,000<br>–40…+70<br>IP20<br>®<br>&RinaAdis|
8
39 SERIES
39 Series - Relay interface modules 0.1 - 2 - 6 A
B
## _MasterINPUT_ - SSR
##
## Features
1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems
- Jumper link option for the quick and easy distribution of supply voltage to proximity switches and similar input devices (Bus-bar connection BB)
- UL Listing (certain relay/socket combinations)
- 0.1 or 2 A solid state relay
- 6 - 12 - 24 V DC, 24 - 125 V AC/DC and 230 V AC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
39.40 39.70 Screw terminal Push-in terminal
For outline drawing see page 20, 21
|Output specification (SSR)|||39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240|39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240|
|---|---|---|---|---|
|Contact configuration|||1 NO (SPST-NO)||
|Rated current/Maximum peak current (10 ms)||A|2/20 DC 0.1/0.5 DC 2/40 AC|2/20 DC 0.1/0.5 DC 2/40 AC|
|Rated voltage/Maximum blocking voltage|Rated voltage/Maximum blocking voltage|V|24/33 DC 48/60 DC 240/— AC|24/33 DC 48/60 DC 240/— AC|
|Switching voltage range||V|(1.5…24) DC (1.5…48) DC (12…275) AC|(1.5…24) DC (1.5…48) DC (12…275) AC|
|Repetitive peak off-state voltage||Vpk|— — 600|— — 600|
|Minimum switching current||mA|1 0.05 22|1 0.05 22|
|Max. “OFF-state” leakage current||mA|0.001 0.001 1.5|0.001 0.001 1.5|
|Max. “ON-state” voltage drop||V|0.12 1 1.6|0.12 1 1.6|
|Supply specification|||||
|Nominal voltage (UN)|V AC/DC|V AC/DC|24 - 110...125||
||V AC (50/60 Hz)||220...240||
|||V DC|6 - 12 - 24||
|Rated power|VA (50 Hz)/W|VA (50 Hz)/W|Seepage 17||
|Operating range|||(0.8…1.1)UN||
|Must drop-out voltage|||0.1 UN||
|Technical data|||||
|Operate/release time||ms|0.2/0.6 0.04/0.11 12|0.11 12/12|
|Dielectric strength between input/output||V AC|2,500||
|Ambient temperature range||°C|–20…+55||
|Protection category|||IP20||
|Approvals relay(according to type)|||C€FAl<br>T<br>C&Ais|Y<br>Ais|
9
39 SERIE S 39 Series - Relay interface modules 0.1 - 2 - 6 A
## _MasterOUTPUT_ - EMR
## 39.21/39.51
## Features
1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems
- Jumper link option for the quick and easy distribution of supply voltage to output side
- B (Bus-bar connection BB) and its connection to electromagnetic valves and similar output devices
- UL Listing (certain relay/socket combinations)
- 6 A electromechanical relay
- 6 - 12 - 24 - 125 V AC/DC and 230 V AC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
39.21 39.51 Screw terminal Push-in terminal
For outline drawing see page 20, 21
|Contact specification||||1|
|---|---|---|---|---|
|Contact configuration|||1 NO (SPST-NO)||
|Rated current/Maximumpeak current||A||6/10|
|Rated voltage/Maximum switchingvoltage||V AC||250/400|
|Rated load AC1||VA||1,500|
|Rated load AC15 (230 V AC)||VA||300|
|Singlephase motor rating(230 V AC)||kW||0.185|
|Breaking capacityDC1: 30/110/220 V||A||6/0.2/0.12|
|Minimum switching load|mW (V/mA)|||500 (12/10)|
|Standard contact material||||AgNi|
|Supply specification|||||
|Nominal voltage (UN)|V AC/DC||6 - 12 - 24 - 110…125||
||V AC (50/60 Hz)||V AC (50/60 Hz)|220...240|
|Rated power|VA (50 Hz)/W|||See page 16|
|Operating range||||(0.8…1.1) UN|
|Holding voltage||||0.6 UN|
|Must drop-out voltage||||0.1 UN|
|Technical data|||||
|Mechanical life AC/DC||cycles||10 · 10<br>6|
|Electrical life at rated load AC1||cycles||60 · 10<br>3|
|Operate/release time||ms||5/6|
|Insulation between coil and contacts (1.2/50 μs)<br>Dielectric strength between open contacts<br>Ambient temperature range<br>Protection category<br>Approvals relay(according to type)||kV<br>V AC<br>°C|C€@EAL|6 (8 mm)<br>1,000<br>–40…+70<br>IP20<br>&<br>rinaWis|
10
39 SERIES
39 Series - Relay interface modules 0.1 - 2 - 6 A
B
## _MasterOUTPUT_ - SSR
## 39.20/39.50
## Features
1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems
- Jumper link option for the quick and easy distribution of supply voltage to output side (Bus-bar connection BB) and its connection to electromagnetic valves and similar output devices
- UL Listing (certain relay/socket combinations)
- 0.1 or 2 A solid state relay
- 6 to 24 V DC, 125 V AC/DC and 230 V AC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
**==> picture [114 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.20 39.50<br>Screw terminal Push-in terminal<br>**----- End of picture text -----**<br>
For outline drawing see page 20, 21
|Output specification (SSR)|||39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240|39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240|
|---|---|---|---|---|
|Contact configuration|||1 NO (SPST-NO)||
|Rated current/Maximum peak current (10 ms)||Rated current/Maximum peak current (10 ms)<br>A|2/20 DC 0.1/0.5 DC 2/40 AC|2/20 DC 0.1/0.5 DC 2/40 AC|
|Rated voltage/Maximum blocking voltage|Rated voltage/Maximum blocking voltage|V|24/33 DC 48/60 DC 240/— AC|24/33 DC 48/60 DC 240/— AC|
|Switching voltage range||V|(1.5…24) DC (1.5…48) DC (12…275) AC|(1.5…24) DC (1.5…48) DC (12…275) AC|
|Repetitive peak off-state voltage||Vpk|— — 600|— — 600|
|Minimum switching current||mA|1 0.05 22|1 0.05 22|
|Max. “OFF-state” leakage current||mA|0.001 0.001 1.5|0.001 0.001 1.5|
|Max. “ON-state” voltage drop||V|0.12 1 1.6|0.12 1 1.6|
|Supply specification|||||
|Nominal voltage (UN)|V AC/DC|V AC/DC|110...125||
||V AC (50/60 Hz)||220...240||
|||V DC|6 - 12 - 24||
|Rated power|VA (50 Hz)/W|VA (50 Hz)/W|Seepage 17||
|Operating range|||(0.8…1.1) UN||
|Must drop-out voltage|||0.1 UN||
|Technical data|||||
|Operate/release time||ms|0.2/0.6 0.04/0.11 12|0.11 12/12|
|Dielectric strength between input/output||V AC|2,500||
|Ambient temperature range||°C|–20…+55||
|Protection category|||IP20||
|Approvals relay(according to type)|||C€FAL<br>&Ais|®<br>Ais|
11
39 SERIE S 39 Series - Relay interface modules 0.1 - 2 - 6 A
## _MasterTIMER_ - EMR
## 39.81/39.91
## Features
Slim timed interface module, 6.2 mm wide, ideal for space-saving timing solutions in panels
B
- Timer adjustment via top mounted rotary knob, accessible after assembly
- Control signal terminal
- DIP-switch for selection of 4 time scales and 8 functions
- Accepts output fuse module 093.63 (for 5 x 20 mm fuses) for quick and easy load protection, see page 24
- Common connection possible with optional jumper links (terminals A1, A2 and 15)
- UL Listing (certain relay/socket combinations)
- 6 A electromechanical relay
- 12 - 24 V AC/DC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
AI: On-delay
DI: Interval
GI: Pulse (0.5 s) delayed
SW: Symmetrical flasher
(starting pulse on)
**==> picture [115 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.81 39.91<br>Screw terminal Push-in terminal<br>**----- End of picture text -----**<br>
Fuse module 093.63
BE: Off-delay with control signal
CE: On- and off-delay with control signal
DE: Interval with control signal on
EE: Interval with control signal off
For outline drawing see page 20, 21
|Contact specification|||||
|---|---|---|---|---|
|Contact configuration||||1 CO (SPDT)|
|Rated current/Maximumpeak current|||A|6/10|
|Rated voltage/Maximum switchingvoltage|||V AC|250/400|
|Rated load AC1|||VA|1,500<br>VA|
|Rated load AC15 (230 V AC)|||VA|300|
|Singlephase motor rating(230 V AC)|||kW|0.185|
|BreakingcapacityDC1: 30/110/220 V||DC1: 30/110/220 V|A|6/0.2/0.12|
|Minimum switchingload||mW (V/mA)||500 (12/10)|
|Standard contact material||||AgNi|
|Supply specification|||||
|Nominal voltage(UN)|||V AC/DC|12 - 24|
|Rated power AC/DC|VA (50 Hz)/W||VA (50 Hz)/W|See page 16|
|Operating range||||(0.8…1.1) UN|
|Holding voltage||||0.6 UN|
|Must drop-out voltage||||0.1 UN|
|Technical data|||||
|Specified time range||||(0.1...3)s, (3...60)s, (1...20)min, (0.3...6)h|
|Repeatability|||%|± 1|
|Recovery time|||ms|≤ 50|
|Minimum control impulse|Minimum control impulse|Minimum control impulse|Minimum control impulse<br>ms|50|
|Setting accuracy – full range<br>Electrical life at rated load AC1<br>Ambient temperature range<br>Protection category<br>Approvals relay(according to type)|||%<br>cycles<br>°C|5<br>60 · 10<br>3<br>–20...+50<br>IP20<br>CE@FAL&RINAAis|
12
39 SERIES
39 Series - Relay interface modules 0.1 - 2 - 6 A
B
## _MasterTIMER_ - SSR
39.80/39.90
## Features
Slim timed interface module, 6.2 mm wide, ideal for space-saving timing solutions in panels
- Timer adjustment via top mounted rotary knob; accessible after assembly
- Start terminal
- DIP-switch for selection of 4 time scales and 8 functions
- Accepts output fuse module 093.63 (for 5 x 20 mm fuses) for quick and easy load protection, see page 24
- Common connection possible with optional jumper links (terminals A1, A2 and 15+)
- UL Listing (certain relay/socket combinations)
- 0.1 or 2 A solid state relay
- 12 - 24 V AC/DC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
AI: On-delay
DI: Interval
GI: Pulse (0.5 s) delayed
SW: Symmetrical flasher (starting pulse on)
**==> picture [111 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.80 39.90<br>Screw terminal Push-in terminal<br>**----- End of picture text -----**<br>
**==> picture [38 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse module<br>093.63<br>**----- End of picture text -----**<br>
BE: Off-delay with control signal CE: On- and off-delay with control signal DE: Interval with control signal on
EE: Interval with control signal off
For outline drawing see page 20, 21
|Output specification (SSR)|||39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240|39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240|
|---|---|---|---|---|
|Contact configuration|||1 NO (SPST-NO)||
|Rated current/Maximum peak current (10 ms)|Rated current/Maximum peak current (10 ms)|Rated current/Maximum peak current (10 ms)<br>A|2/20 DC 0.1/0.5 DC 2/40 AC|2/20 DC 0.1/0.5 DC 2/40 AC|
|Rated voltage/Maximum blocking voltage||V|24/33 DC 48/60 DC 240/— AC|24/33 DC 48/60 DC 240/— AC|
|Switching voltage range||V|(1.5…24) DC (1.5…48) DC (12…275) AC|(1.5…24) DC (1.5…48) DC (12…275) AC|
|Repetitive peak off-state voltage|Repetitive peak off-state voltage|Repetitive peak off-state voltage<br>Vpk|— — 600|— — 600|
|Minimum switching current|Minimum switching current|Minimum switching current<br>mA|1 0.05 22|1 0.05 22|
|Max. “OFF-state” leakage current|Max. “OFF-state” leakage current|Max. “OFF-state” leakage current<br>mA|0.001 0.001 1.5|0.001 0.001 1.5|
|Max. “ON-state” voltage drop|Max. “ON-state” voltage drop|Max. “ON-state” voltage drop<br>V|0.12 1 1.6|0.12 1 1.6|
|Supply specification|||||
|Nominal voltage (UN)|)<br>V AC/DC|)<br>V AC/DC|12 - 24||
|Rated power|Rated power<br>VA (50 Hz)/W|Rated power<br>VA (50 Hz)/W|See page 17||
|Operating range|Operating range|Operating range|(0.8…1.1) UN||
|Holding voltage|||0.6 UN||
|Must drop-out voltage|Must drop-out voltage|Must drop-out voltage|0.1 UN||
|Technical data|||||
|Specified time range|||(0.1...3)s, (3...60)s, (1...20)min, (0.3...6)h||
|Repeatability|Repeatability|Repeatability<br>%|± 1||
|Recovery time||ms|≤ 50||
|Minimum control impulse||ms|50||
|Setting accuracy – full range||%|5||
|Ambient temperature range<br>Protection category<br>Approvals relay(according to type)|Ambient temperature range|Ambient temperature range<br>°C|–20...+50<br>IP20<br>C€FAL~~&~~Ais|Ais|
## 39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240
13
39 SERIE S 39 Series - Relay interface modules - Ordering information
## Ordering information
Example: _MasterPLUS_ 39 series screw terminal interface module, electromechanical relay output, 1 CO (SPDT), 24 V AC/DC coil.
A B C D 3 9 . 3 1 . 0 . 0 2 4 . 0 0 6 0
B
Series
Type
- 1 = _MasterBASIC_ , screw terminal
- 0 = _MasterBASIC_ , push-in terminal
- 3 = _MasterPLUS_ , screw terminal, fuse-protectable output
- 6 = _MasterPLUS_ , push-in terminal, fuse-protectable output
- 4 = _MasterINPUT_ , screw terminal
- 7 = _MasterINPUT_ , push-in terminal
- 2 = _MasterOUTPUT_ , screw terminal
D: Special Version, EMR 0 = Standard
C: Options, EMR
- 6 = Standard
B: Contact circuit, EMR
- 0 = CO (except 39.21/51, 1 NO)
A: Contact material, EMR
- 0 = AgNi Standard
- 4 = AgSnO2
- 5 = AgNi + Au
- 5 = _MasterOUTPUT_ , push-in terminal
- 8 = _MasterTIMER_ multifunction, screw terminal, fuse-protectable output
- 9 = _MasterTIMER_ multifunction, push-in terminal, fuse-protectable output
ABCD: Output version, SSR 7048 = 0.1 A - 48 V DC 8240 = 2 A - 230 V AC 9024 = 2 A - 24 V DC
No. of poles
- 1 = 1 CO (only EMR, except 39.21/51, 1 NO)
- 0 = 1 NO (only SSR)
Coil version, EMR / Input version, SSR
- 0 = AC (50/60 Hz)/DC
- 3 = Leakage current suppression AC (50/60 Hz)
- 7 = DC sensitive
- 8 = AC (50/60 Hz)
Coil voltage, EMR / Input voltage, SSR See page 16
EMR - Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold.
**==> picture [263 x 181] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type Coil version A B C D<br>0.006 - 0.012<br>39.11/01 0 - 4 - 5 0 6 0<br>0.024 - 0.125 - 8.230<br>0.006 - 0.012<br>0.024 - 0.060<br> 39.31/61 0.125 - 0.240 - 8.230 0 - 4 - 5 0 6 0<br>7.125 - 7.220<br>3.125 - 3.230<br>0.006 - 0.012<br>39.41/71 0.024 - 0.125 0 - 4 - 5 0 6 0<br>8.230<br>0.006 - 0.012<br>39.21/51 0.024 - 0.125 0 - 4 - 5 0 6 0<br>8.230<br>39.81/91 0.012 - 0.024 0 0 6 0<br>**----- End of picture text -----**<br>
SSR - Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold.
|Type|Input version|Output version, ABCD|
|---|---|---|
|39.10/00|7.006 - 7.012<br>7.024 - 0.125 -8.230|7048 - 8240 -**9024**|
||7.006 - 7.012||
||7.024 - 7.060||
||7.125 - 7.220||
|39.30/60|0.024 - 0.125 - 0.240|7048 - 8240 -**9024**|
||8.230||
||3.125 - 3.230||
|39.40/70<br>39.20/50<br>39.80/90|7.006 - 7.012<br>7.024 - 0.024 - 0.125<br>8.230<br>7.006 - 7.012<br>7.024 - 0.125<br>8.230<br>0.012 -0.024|7048 - 8240 -**9024**<br>7048 - 8240 -**9024**<br>7048 - 8240 -**9024**|
14
39 SERIES
39 Series - Relay interface modules - Technical data
## Technical data
|Insulation according to EN 61810-1|Insulation according to EN 61810-1|Insulation according to EN 61810-1|Insulation according to EN 61810-1|Insulation according to EN 61810-1|Insulation according to EN 61810-1|Insulation according to EN 61810-1|
|---|---|---|---|---|---|---|
|Nominal voltage of supplysystem<br>V AC|||230/400||||
|Rated insulation voltage<br>V AC|||250||400||
|Pollution degree|||3||2||
|Insulation between coil and contact set|||||||
|Type of Insulation|||Reinforced||||
|Overvoltage category|||III||||
|Rated impulse voltage<br>kV(1.2/50) μs|||6||||
|Dielectric strength<br>V AC|||4,000||||
|Insulation between open contacts(EMR)|||||||
|Type of disconnection|||Micro-disconnection||||
|Dielectric strength<br>V AC/kV(1.2/50) μs|||1,000/1.5||||
|Conducted disturbance immunity|||UN≤ 60 V|UN= 125 V||UN= 230 V|
|Fast transients (burst 5/50 ns, 5 kHz) according to EN 61000-4-4<br>at supplyterminals||kV|4|4||4|
|Voltage pulses (surge 1.2/50 μs) according to EN 61000-4-5 at<br>supplyterminals(differential mode)||kV|0.8|2||4|
|Other data|||||||
|Bounce time(EMR): NO/NC||ms|1/6||||
|Vibration resistance(EMR,10..55 Hz):|NO/NC|g|10/15||||
|Power lost to the environment|without contact current|W|0.2(24 V)– 0.4(230 V)||||
||with rated current|W|0.6(24 V)– 0.9(230 V)||||
|Terminals|||||||
||||Screw terminal||Push-in terminal||
|Wire striplength<br>S t||mm<br>N|10<br>05||8||
|crew orque||m|.<br>Solid and stranded cable||—<br>Solid and stranded cable||
|Max. wire size||mm2|1 x 2.5/2 x 1.5||1 x 2.5||
|||AWG|1 x 14/2 x 16||1 x 14||
|Min. wire size||mm2|1 x 0.2||1 x 0.2||
|||AWG|1 x 24||1 x 24||
B
## Contact specification (EMR)
F 39 - Electrical life (AC) v contact current
**==> picture [252 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
Resistive load - cosϕ = 1<br>Cycles Inductive load - cosϕ = 0.4<br>**----- End of picture text -----**<br>
## H 39 - Maximum DC1 breaking capacity
**==> picture [251 x 163] intentionally omitted <==**
**----- Start of picture text -----**<br>
DC voltage (V)<br>• When switching a resistive load (DC1) having voltage and current<br>values under the curve, an electrical life of ≥ 60·103 can be expected.<br>DC breaking current (A)<br>**----- End of picture text -----**<br>
- In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased.
15
39 SERIE S 39 Series - Relay interface modules - Technical data
## Coil specifications - Electromechnical Relay
## Coil data DC, type 39.31/61
**==> picture [318 x 90] intentionally omitted <==**
**----- Start of picture text -----**<br>
Nominal Must drop-out Rated input<br>Coil code Operating range Rated power<br>Voltage voltage current at UN<br>UN Umin Umax Ur IN at UN<br>V V V V mA W<br>B 125 7 .125 88 138 12.5 4.6 0.6<br>(110...125)<br>220 7 .220 176 242 22 3.0 0.6<br>**----- End of picture text -----**<br>
## Coil data AC/DC, type 39.11/21/31/41/01/51/61/71
|Nominal<br>Voltage|Coil code|Operating range|Operating range|Must drop-out<br>voltage|Rated input<br>current at UN|Rated power|
|---|---|---|---|---|---|---|
|UN||Umin|Umax|Ur|IN|at UN|
|V||V|V|V|mA|VA/W|
|6|**0**.006|4.8|6.6|0.6|35|0.2/0.2|
|12|**0**.012|9.6|13.2|1.5|15|0.2/0.2|
|24|**0**.024|19.2|26.4|2.4|11|0.25/0.25|
|60(1)|**0**.060|48|66|6.0|5.7|0.35/0.35|
|125<br>(110…125)|**0**.125|88|138|12.5|5.6|0.7/0.7|
|240<br>(24…240)(2)|**0**.240|20.4|264|2.4|19|1.5/0.3|
(1) 60 V AC/DC for type 39.31/61 only (2) 24...240 V AC/DC for type 39.31/61 only
## Coil data AC, type 39.11/21/31/41/01/51/61/71
|Nominal<br>Voltage|Coil code|Operating range|Operating range|Must drop-out<br>voltage|Rated input<br>current at UN|Rated power|
|---|---|---|---|---|---|---|
|UN||Umin|Umax|Ur|IN|at UN|
|V||V|V|V|mA|VA/W|
|230<br>(230...240)|**8**.230|184|264|23|4.3|1/0.4|
## Coil data leakage current suppression versions, type 39.31.3/61.3
|Nominal<br>Voltage|Coil code|Operating range|Operating range|Must drop-out<br>voltage|Rated input<br>current at UN|Rated power|
|---|---|---|---|---|---|---|
|UN||Umin|Umax|Ur|IN|at UN|
|V||V|V|V|mA|VA/W|
|125<br>(110...125)|**3**.125|88|138|44|8.4|1.1/1|
|230<br>(230...240)|**3**.230|184|264|72|5.9|1.4/0.5|
The 39 Series interface modules (supply version 3) have builtin leakage current suppression to address industry concerns of the contacts not dropping-out when there is residual current in the circuit; at (110...125)V AC/DC and (230...240)V AC. This problem can occur, for example, when connecting the interface modules to PLC‚s with triac outputs or when connecting via relatively long cables.
## Coil data AC/DC timer, type 39.81/91
|Nominal<br>Voltage|Coil code|Operating range<br>(AC/DC)|Operating range<br>(AC/DC)|Must drop-out<br>voltage|Rated input current at UN|Rated input current at UN|Rated power at UN|Rated power at UN|
|---|---|---|---|---|---|---|---|---|
|UN||Umin|Umax|Ur|DC|AC|DC|AC|
|V||V|V|V|mA|mA|W|VA/W|
|12|**0**.012|9.6|13.2|1.2|15|23|0.2|0.3/0.2|
|24|**0**.024|19.2|26.4|2.4|11|19|0.25|0.4/0.3|
16
39 SERIES
39 Series - Relay interface modules - Technical data
## Input specifications - Solid State Relay
## Input data DC, type 39.10/20/30/40/00/50/60/70
**==> picture [290 x 143] intentionally omitted <==**
**----- Start of picture text -----**<br>
Nominal Must drop-out Rated input Rated<br>Input code Operating range<br>Voltage voltage current at UN power<br>UN Umin Umax Ur IN at UN<br>V V V V mA W<br>6 7 .006 4.8 6.6 0.6 7.5 0.2<br>12 7 .012 9.6 13.2 1.2 20.7 0.25<br>24 7 .024 19.2 26.4 2.4 10.5 0.25<br>60 [(1)] 7 .060 48 66 6.0 6.4 0.4<br>125 [(1)]<br>7 .125 88 138 12.5 4.6 0.6<br>(110...125)<br>220 [(1)] 7 .220 176 242 22 3.0 0.6<br>**----- End of picture text -----**<br>
(1) 60 V DC, 125 V DC and 220 V DC for type 39.30/60 only
B
## Input data AC/DC, type 39.10/20/30/40/00/50/60/70
|Nominal<br>Voltage|Input code|Operating range|Operating range|Must drop-out<br>voltage|Rated input<br>current at UN|Rated<br>power|
|---|---|---|---|---|---|---|
|UN||Umin|Umax|Ur|IN|at UN|
|V||V|V|V|mA|VA/W|
|24 (2)|**0**.024|19.2|26.4|2.4|17.5|0.4/0.3|
|125<br>(110...125)|**0**.125|88|138|12.5|5.5|0.7/0.7|
|240<br>(24...240)(3)|**0**.240|20.4|264|2.4|17.5|1.5/0.3|
(2) 24 V AC/DC for type 39.30/40/60/70 only (3) 24...240 V AC/DC for type 39.30/60 only
## Input data AC, type 39.10/20/30/40/00/50/60/70
|Nominal<br>Voltage|Input code|Operating range|Operating range|Must drop-out<br>voltage|Rated input<br>current at UN|Rated<br>power|
|---|---|---|---|---|---|---|
|UN||Umin|Umax|Ur|IN|at UN|
|V||V|V|V|mA|VA/W|
|230<br>(230...240)|**8**.230|184|264|23|4.2|1/0.4|
## Input data leakage current suppression versions, type 39.30.3/60.3
|Nominal<br>Voltage|Input code|Operating range|Operating range|Must drop-out<br>voltage|Rated input<br>current at UN|Rated<br>power|
|---|---|---|---|---|---|---|
|UN||Umin|Umax|Ur|IN|at UN|
|V||V|V|V|mA|VA/W|
|125<br>(110...125)|**3**.125|88|138|44|8.4|1.1/1|
|230<br>(230...240)|**3**.230|184|264|72|5.9|1.4/0.5|
The 39 Series interface modules (supply version 3) have builtin leakage current suppression to address industry concerns of the contacts not dropping-out when there is residual current in the circuit; at (110...125)V AC/DC and (230...240)V AC. This problem can occur, for example, when connecting the interface modules to PLC‚s with triac outputs or when connecting via relatively long cables.
## Input data AC/DC timer, type 39.80/90
|Nominal<br>Voltage|Input code|Operating range<br>(AC/DC)|Operating range<br>(AC/DC)|Must drop-out<br>voltage|Rated input current at UN|Rated input current at UN|Rated power at UN|Rated power at UN|
|---|---|---|---|---|---|---|---|---|
|UN||Umin|Umax|Ur|DC|AC|DC|AC|
|V||V|V|V|mA|mA|W|VA/W|
|12|**0**.012|9.6|13.2|1.2|15|23|0.2|0.3/0.2|
|24|**0**.024|19.2|26.4|2.4|11|19|0.25|0.4/0.3|
17
39 SERIE S
39 Series - Timed interface modules
## Timer specifications
||Timer specifications|Timer specifications||||
|---|---|---|---|---|---|
||EMC specifications|||||
||Type of test|||Reference standard||
||Electrostatic discharge||contact discharge|EN 61000-4-2|4 kV|
||||air discharge|EN 61000-4-2|8 kV|
|B|Radio-frequency electromagnetic field||(80 ÷ 1,000 MHz)|EN 61000-4-3|10 V/m|
||||(1,400 ÷ 2,700 MHz)|EN 61000-4-3|10 V/m|
||Fast transients (burst) (5-50 ns, 5 and 100 kHz)||on Supplyterminals|EN 61000-4-4|4 kV|
||||on control signal terminals|EN 61000-4-4|4 kV|
||Surges (1.2/50 μs) on supply and control<br>signal terminals||common mode|EN 61000-4-5|2 kV|
|||||||
||||differential mode|EN 61000-4-5|0.8 kV|
||Radio-frequency common mode<br>(0.15 ÷ 80 MHz)||on Supplyterminals|EN 61000-4-6|10 V|
||||on control signal terminals|EN 61000-4-6|3 V|
||Radiated and conducted emission|||EN 55022|class B|
||Other data|||||
||Bounce time(EMR): NO/NC||ms|1/6||
||Vibration resistance(EMR,10..55 Hz):|NO/NC|<br>g|10/15||
||Power lost to the environment|without contact current<br>W||0.3||
|||with rated current<br>W||0.8||
||Terminals|||||
|||||Screw terminal|Push-in terminal|
||Wire striplength<br>S t|mm<br>N||10<br>05|8|
||crew orque|m||.<br>Solid and stranded cable|—<br>Solid and stranded cable|
||Max. wire size|mm2||1 x 2.5/2 x 1.5|1 x 2.5|
|||AWG||1 x 14/2 x 16|1 x 14|
||Min. wire size|mm2||1 x 0.2|1 x 0.2|
|||AWG||1 x 24|1 x 24|
Times scales
|1|2 3 4 5|1 2 3 4 5|1 2 3 4 5|1 2 3 4 5|
|---|---|---|---|---|
||(0.1...3)s|(3...60)s|(1...20)min|(0.3...6)h|
Functions
||LED|Supply voltage|NO contact/output|
|---|---|---|---|
|||OFF|Open|
|||ON|Open|
|||ON|Open (timing to close in progress)|
|||ON|Closed|
18
39 SERIES
39 Series - Timed interface modules
|Wiring diagram<br>U = Supply voltage|Wiring diagram<br>U = Supply voltage|||||||
|---|---|---|---|---|---|---|---|
|Without control signal|1 2 3 4 5<br>1 2 3 4 5<br>1 2 3 4 5<br>1 2 3 4 5||||||(AI)On-delay<br>Apply power to timer. Output contacts transfer after<br>preset time has elapsed. Reset occurs when power is<br>removed.<br>(DI)Interval<br>Apply power to timer. Output contacts transfer<br>immediately. After the preset time has elapsed, contacts<br>reset.<br>(GI)Pulse (0.5s) delayed<br>Apply power to timer. Output contacts transfer after<br>preset time has elapsed. Reset occurs after a fixed time<br>of 0.5s.<br>(SW)Symmetrical flasher (starting pulse on)<br>Apply power to timer. Output contacts transfer<br>immediately and cycle between ON and OFF for as<br>long as power is applied. The ratio is 1:1 (time on =<br>time off).|
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|*With DC supply,<br>positive polarity has to<br>be conneted to B1,<br>terminal (according to<br>EN 60204-1).<br>With control signal<br>*|1 2 3 4 5<br>1 2 3 4 5<br>1 2 3 4 5<br>1 2 3 4 5||||||(BE)Off-delay with control signal<br>Power is permenently applied to the timer. The<br>output contacts transfer immediately on closure of the<br>Signal Switch (S). Opening the Signal Switch<br>initiates the preset delay, after which time the output<br>contacts reset.<br>(DE)Interval with control signal on<br>Power is permenently applied to the timer. On momentary<br>or maintained closure of Signal Switch (S), the output<br>contacts transfer, and remain so for the duration of<br>the preset delay, after which they reset.<br>(EE)Interval with control signal off<br>Power is permenently applied to the timer. On opening<br>of the Signal Switch (S) the output contacts transfer,<br>and remain so for the duration of the preset delay,<br>after which they reset.<br>(CE)On- and off-delay with control signal<br>Power is permenently applied to the timer. Closing the<br>Signal Switch (S) initiates the preset delay, after which<br>time the output contacts transfer. Opening the Signal<br>switch initiates the same preset delay, after which time<br>the output contacts reset.|
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
|||||||||
**==> picture [55 x 39] intentionally omitted <==**
- Possible to control an external load, such as another relay coil or timer, connected to the control signal terminal B1.
** A voltage other than the supply voltage can be applied to the command Start (B1), example: A1 - A2 = 24 V AC B1 - A2 = 12 V DC
19
39 SERIE S 39 Series - Relay interface modules 0.1 - 2 - 6 A
Outline drawings - Screw terminal sockets
**==> picture [79 x 97] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.10 / 39.20<br>39.11 / 39.21<br>Screw terminal<br>B<br>**----- End of picture text -----**<br>
**==> picture [37 x 50] intentionally omitted <==**
**==> picture [46 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.40<br>39.41<br>Screw terminal<br>**----- End of picture text -----**<br>
**==> picture [83 x 52] intentionally omitted <==**
**==> picture [125 x 263] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.30 / 39.30.3<br>39.31 / 39.31.3<br>Screw terminal<br>39.80<br>39.81<br>Screw terminal<br>**----- End of picture text -----**<br>
**==> picture [87 x 52] intentionally omitted <==**
20
39 39 Series - Relay interface modules 0.1 - 2 - 6 A SERIES
B
## Outline drawings - Push-in terminal sockets
39.00 / 39.01 39.50 / 39.51 Push-in terminal
**==> picture [31 x 31] intentionally omitted <==**
**==> picture [56 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.60 / 39.60.3<br>39.61 / 39.61.3<br>Push-in terminal<br>**----- End of picture text -----**<br>
**==> picture [31 x 31] intentionally omitted <==**
**==> picture [48 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.70<br>39.71<br>Push-in terminal<br>**----- End of picture text -----**<br>
**==> picture [31 x 32] intentionally omitted <==**
**==> picture [48 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.90<br>39.91<br>Push-in terminal<br>**----- End of picture text -----**<br>
**==> picture [31 x 31] intentionally omitted <==**
## Main features
## Push-in terminals
The push-in terminals permit the quick connection of solid wires or ferrules by their simple insertion into the terminal (A). It is possible to open the terminal to extract the wire by first pushing down on the push-button using a screwdriver (C). For stranded cable it is necessary first to open the terminal using the push button, both for the extraction (C) and insertion (B). It is possible at any time to check the connection via the test aperture, using a 2mm diameter test probe (D).
**==> picture [439 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
A B C D<br>I-2015, www.findernet.com<br>**----- End of picture text -----**<br>
21
39 SERIE S 39 Series - Relay interface modules 0.1 - 2 - 6 A
B
Electromechanical Relay (1 Pole 6 A) & Screw Socket Combinations
|Example: .xxxx<br>.9024<br>.7048<br>.8240|Interface Module Code|Coil voltage|Relay|Socket|
|---|---|---|---|---|
||<br>_MasterBASIC_||||
||39.11.0.006.0060|6 V AC/DC|34.51.7.005.0010|93.61.7.024|
||39.11.0.012.0060|12 V AC/DC|34.51.7.012.0010|93.61.7.024|
||39.11.0.024.0060|24 V AC/DC|34.51.7.024.0010|93.61.7.024|
||39.11.0.125.0060|(110...125)V AC/DC|34.51.7.060.0010|93.61.0.125|
||<br>39.11.8.230.0060|<br>(230...240)V AC|<br>34.51.7.060.0010|<br>93.61.8.230|
||<br>_MasterPLUS_||||
||39.31.0.006.0060|6 V AC/DC|34.51.7.005.0010|93.63.7.024|
||39.31.0.012.0060|12 V AC/DC|34.51.7.012.0010|93.63.7.024|
||39.31.0.024.0060|24 V AC/DC|34.51.7.024.0010|93.63.7.024|
||39.31.0.060.0060|60 V AC/DC|34.51.7.060.0010|93.63.7.060|
||39.31.0.125.0060|(110...125)V AC/DC|34.51.7.060.0010|93.63.0.125|
||<br>39.31.0.240.0060|<br>(24...240)V AC/DC|<br>34.51.7.024.0010|<br>93.63.0.240|
||<br>39.31.8.230.0060|<br>(230...240)V AC|<br>34.51.7.060.0010|<br>93.63.8.230|
||<br>39.31.7.125.0060|<br>(110...125)V DC|<br>34.51.7.060.0010|<br>93.63.7.125|
||<br>39.31.7.220.0060|<br>220 V DC|<br>34.51.7.060.0010|<br>93.63.7.220|
||39.31.3.125.0060|(110...125)V AC/DC|34.51.7.060.0010|93.63.3.125|
||<br>39.31.3.230.0060|<br>(230...240)V AC|<br>34.51.7.060.0010|<br>93.63.3.230|
||<br>_MasterINPUT_||||
||39.41.0.006.5060|6 V AC/DC|34.51.7.005.5010|93.64.7.024|
||39.41.0.012.5060|12 V AC/DC|34.51.7.012.5010|93.64.7.024|
||39.41.0.024.5060|24 V AC/DC|34.51.7.024.5010|93.64.7.024|
||39.41.0.125.5060|(110…125) V AC/DC|34.51.7.060.5010|93.64.0.125|
||<br>39.41.8.230.5060|<br>(230...240)V AC|<br>34.51.7.060.5010|<br>93.64.8.230|
||<br>_MasterOUTPUT_1 NO, 6 A only||||
||<br>39.21.0.006.0060|<br>6 V AC/DC|34.51.7.005.0010|93.62.7.024|
||39.21.0.012.0060|12 V AC/DC|34.51.7.012.0010|93.62.7.024|
||39.21.0.024.0060|24 V AC/DC|34.51.7.024.0010|93.62.7.024|
||39.21.0.125.0060|(110…125) V AC/DC|34.51.7.060.0010|93.62.0.125|
||<br>39.21.8.230.0060|<br>(230...240)V AC|<br>34.51.7.060.0010|<br>93.62.8.230|
||<br>_MasterTIMER_||||
||39.81.0.012.0060|12 V AC/DC|34.51.7.012.0010|93.68.0.024|
||39.81.0.024.0060|24 V AC/DC|34.51.7.024.0010|93.68.0.024|
||Solid State Relay(1 Pole 0.1 or 2 A) & Screw Socket Combinations||||
||Interface Module Code|Input voltage|Relay|Socket|
||<br>_MasterBASIC_||||
||39.10.7.006.xxxx|6 V DC|34.81.7.005.xxxx|93.61.7.024|
||39.10.7.012.xxxx|12 V DC|34.81.7.012.xxxx|93.61.7.024|
||39.10.7.024.xxxx|24 V DC|34.81.7.024.xxxx|93.61.7.024|
||39.10.0.125.xxxx|(110...125)V AC/DC|34.81.7.060.xxxx|93.61.0.125|
||<br>39.10.8.230.xxxx|<br>(230...240)V AC|<br>34.81.7.060.xxxx|<br>93.61.8.230|
||<br>_MasterPLUS_||||
||39.30.7.006.xxxx|6 V DC|34.81.7.005.xxxx|93.63.7.024|
||39.30.7.012.xxxx|12 V DC|34.81.7.012.xxxx|93.63.7.024|
||39.30.7.024.xxxx|24 V DC|34.81.7.024.xxxx|93.63.7.024|
||39.30.7.060.xxxx|60 V DC|34.81.7.060.xxxx|93.63.7.060|
||39.30.7.125.xxxx|(110...125)V DC|34.81.7.060.xxxx|93.63.7.125|
||<br>39.30.7.220.xxxx|<br>220 V DC|<br>34.81.7.060.xxxx|<br>93.63.7.220|
||39.30.0.024.xxxx|24 V AC/DC|34.81.7.024.xxxx|93.63.0.024|
||39.30.0.125.xxxx|(110...125)V AC/DC|34.81.7.060.xxxx|93.63.0.125|
||<br>39.30.0.240.xxxx|<br>(24...240)V AC/DC|<br>34.81.7.024.xxxx|<br>93.63.0.240|
||<br>39.30.8.230.xxxx|<br>(230...240)V AC|<br>34.81.7.060.xxxx|<br>93.63.8.230|
||<br>39.30.3.125.xxxx|<br>(110...125)V AC/DC|<br>34.81.7.060.xxxx|<br>93.63.3.125|
||<br>39.30.3.230.xxxx|<br>(230...240)V AC|<br>34.81.7.060.xxxx|<br>93.63.3.230|
||<br>_MasterINPUT_||||
||39.40.7.006.xxxx|6 V DC|34.81.7.005.xxxx|93.64.7.024|
||39.40.7.012.xxxx|12 V DC|34.81.7.012.xxxx|93.64.7.024|
||39.40.7.024.xxxx|24 V DC|34.81.7.024.xxxx|93.64.7.024|
||39.40.0.024.xxxx|24 V AC/DC|34.81.7.024.xxxx|93.64.0.024|
||39.40.0.125.xxxx|(110…125) V AC/DC|34.81.7.060.xxxx|93.64.0.125|
||<br>39.40.8.230.xxxx|<br>(230...240)V AC|<br>34.81.7.060.xxxx|<br>93.64.8.230|
||<br>_MasterOUTPUT_||||
||39.20.7.006.xxxx|6 V DC|34.81.7.005.xxxx|93.62.7.024|
||39.20.7.012.xxxx|12 V DC|34.81.7.012.xxxx|93.62.7.024|
||39.20.7.024.xxxx|24 V DC|34.81.7.024.xxxx|93.62.7.024|
||39.20.0.125.xxxx|(110…125) V AC/DC|34.81.7.060.xxxx|93.62.0.125|
||<br>39.20.8.230.xxxx|<br>(230...240)V AC|<br>34.81.7.060.xxxx|<br>93.62.8.230|
||<br>_MasterTIMER_||||
||39.80.0.012.xxxx|12 V AC/DC|34.81.7.012.xxxx|93.68.0.024|
||39.80.0.024.xxxx|24 V AC/DC|34.81.7.024.xxxx|93.68.0.024|
22
39 39 Series - Relay interface modules 0.1 - 2 - 6 A SERIES
Electromechanical Relay (1 Pole 6 A) & Push-in Socket Combinations
|I-2015, www.findernet.com<br>Example: .xxxx<br>.9024<br>.7048<br>.8240|Interface Module Code|Coil voltage|Relay|Socket|
|---|---|---|---|---|
||39.90.0.012.xxxx|12 V AC/DC|34.81.7.012.xxxx|93.69.0.024|
||39.90.0.024.xxxx|24 V AC/DC|34.81.7.024.xxxx|93.69.0.024|
23
39 SERIE S 39 Series - Relay interface modules 0.1 - 2 - 6 A
## Accessories
Output fuse module for 39.31/30/81/80/61/60/91/90 types
093.63
- For 5 x 20 mm fuses up to 6 A, 250 V
- ad 093.63
- B Approvals (according to type): — ——|
- Easy visibility of the fuse condition through the window
- Quick connection to socket
## Notes
Safety: Because the output circuit can be reinstated (point 3 below), even with the fuse removed, it is important not to consider the removal of the fuse as a “safety disconnect”. Always isolate elsewhere before working on the circuit. UL: According to UL508A, the fuse module cannot be installed in power circuits (in which it is mandatory that a fuse certified according to UL category JDDZ be fitted). However, where the MasterInterface is connected as an output interface to a PLC no such restrictions apply, and the fuse module can be usefully employed.
## Multi-state fuse module
0. As delivered, the socket comes without a fuse module. However, the absent fuse is internally replaced with an electrical link - which allows the interface relay to be used without a fuse module. In this state, the peg/indicator is visually hidden and the connection is protected by a special cap.
1. With fuse module inserted after removing the cap, the fuse is positioned electrically in series with the common output terminal of the interface module (11 for EMR versions, 13+ for SSR versions, 15 for EMR timer, 15+ for SSR timer). This state is indicated by the peg/indicator.
2. If the fuse module is extracted (for example; because the fuse element has blown) the output circuit will be locked open, as this will generally be the “safe option”. This state is indicated by the peg/indicator.
3. In order to reinstate the output circuit it is necessary to either re-insert the fuse module (complete with functional fuse), or alternatively, return the peg/indicator to position 0 by gently applying pressure in the direction of the arrow.
24
39
39 Series - Relay interface modules 0.1 - 2 - 6 A SERIES
## Accessories
16-way jumper link 093.16 (blue) 093.16.0 (black) 093.16.1 (red) Rated values 6 A - 250 V 093.16 Possibility of multiple connection, side by side ‘PRSpyr rrer eeeRT" ~~ener~~ 93 ~~reer~~ 28 093.16.0 Seen = ~~LI 6 VUUUYUUUUUUUUUUUI~~ ~ 093.16.1 1.25 1.25 Approvals 4.95 4.95 (according to type): Cé€ FAL CAMs> 6.2’ 62’ 62 62% ‘62 | Dual-purpose plastic separator (1.8 mm or 6.2 mm separation) 093.60 | 1. By breaking off the protruding ribs (by hand), the separator becomes only 1.8 mm thick; useful for the visual separation of different groups of interfaces, or necessary for the protective separation of different voltages of neighbouring interfaces, or for the protection of cut ends of jumper links. _| | 093.60 1 ay 2! : ey a _ |== **|** A): Sj=—e 2. Leaving the ribs in place provides 6.2mm separation. Simply cutting (with scissors) the relevant segment(s) permits the interconnection across the separator of 2 different groups of interface relays, using the standard jumper link.
**==> picture [10 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>**----- End of picture text -----**<br>
Sheet of marker tags, plastic, 72 tags, 6x12 mm 060.72 |
**==> picture [24 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
060.72<br>**----- End of picture text -----**<br>
**==> picture [24 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
093.62<br>**----- End of picture text -----**<br>
|Terminal doubler (for socket Push-in only) 093.62<br>Total load 6 A - 300 V|(for socket Push-in only) 093.62<br>Total load 6 A - 300 V|
|---|---|
|<br>Max. wire size mm2 2 x 1<br>AWG 2 x 16|Solid and stranded cable|
||2 x 1.5|
||AWG 2 x 16|
25
39 SERIE S 39 Series - Relay interface modules 0.1 - 2 - 6 A
## Accessories
_MasterADAPTER_ 093.68.14.1
The _MasterADAPTER_ permits the easy connection of A1/A2 terminals of up to _MasterINTERFACE_ modules to PLC outputs via a 14-Pole ribbon cable, plus simple 2-wire power supply connection.
**==> picture [82 x 52] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>093.68.14.1<br>Approvals<br>(according to type):<br>**----- End of picture text -----**<br>
**==> picture [84 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Connected MasterADAPTER<br>**----- End of picture text -----**<br>
|Technical data||
|---|---|
|Rated current(per signalpath)A 1<br>Minimum required supply power W 3<br>Nominal voltage(UN) V DC 24<br>Operatingrange<br>Control logic<br>Power supplystatus indication Green LED<br>Ambient temperature range °C –40…+70<br>Terminals for 24 V control logic<br>Type of connector 14 pole, according to IEC 60603-13<br>Terminals for 24 V power supply<br>Wire striplength mm 9.5<br>Screw torque Nm 0.5<br>Max. wire size<br>solid wire mm2 <br>AWG 1 x 12/2 x 16<br>stranded wire mm2 <br>AWG 1 x 14/2 x 16|A 1|
||ower W 3|
||V DC 24|
||e(0.8...1.1)UN|
||icPositive switching (to A1)|
||status indication Green LED|
||Ambient temperature range °C –40…+70<br>Type of connector 14 pole, according to IEC 60603-13<br>th mm 9.5|
||ue Nm 0.5|
||ue Nm 0.5<br> 1 x 4/2 x 1.5|
||AWG 1 x 12/2 x 16|
||1 x 2.5/2 x 1.5|
||AWG 1 x 14/2 x 16|
## Wiring diagram
26
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →