060-T205-01
PRESS TRANSDUCER, 1000PSI, GAUGE, CURRENT
- Manufacturer: HONEYWELL
- Product type: Pressure Transducers
- Port Style: 1/4" - 18 MNPT
- Product Range: FP5000 Series
- Sensor Output: Current
- Operating Pressure Max: 5000psi
- Pressure Measurement Type: Gauge
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 635.56 € |
| Current stock | 10+ |
| Lead time | 7 days |
_008927 Issue 2_ ## MODEL FP5000 ## **Configurable Pressure Transducer** ## DESCRIPTION The Honeywell Model FP5000 Series is a media-isolated piezoresistive silicon pressure sensor offering multiple output options (0 V to 5 V, 0 V to 10 V or 4 mA to 20 mA) for reading pressure over the specified fullscale pressure span and temperature range. It is compensated for sensor offset, sensitivity, temperature effects and non-linearity to offer improved thermal stability and accuracy. Hastelloy® C276 and 316L stainless steel wetted parts provide durability with abrasive or corrosive media. ## DIFFERENTIATION - Offers improved accuracy and reliability - Configurable platform enables a sensor to be built to customer requirements. Simplified nomenclature and order codes makes ordering easier - Many pressure and operating temperature range options - Built from stocked components; most configurations are shipped within ten business days - Extensive history of pressure measurement know-how ## FEATURES - Pressure ranges from 10 in-H2O [0.36 psi] up to 5000 psi - Gage, absolute, vacuum, barometric and compound pressure types - Higher accuracy to 0.1 %FSS BFSL - Multiple output types: 0 Vdc to 5 Vdc, 0 Vdc to 10 Vdc, 4 mA to 20 mA - Multiple electrical and pressure connection options - Zero adjustment through potentiometer - Operating temperature ranges from -40°C to 125°C [-40°F to 250°F] - Multiple compensation temperature ranges - Faster response and higher resolution - Fully analog reduced-noise signal path provides continuous output resolution - Stainless steel construction - Ha C276 and 316L stainless steel wetted parts offer more enhanced durability with abrasive or corrosive media - CE approved - Intrinsically Safe: cFMus, ATEX, IEC Ex certified 2AR option (4 mA to 20 mA) ## APPLICATIONS - Test stands (Automotive, Aerospace, Industrial, and Medical) - R&D test labs - Hydraulic and pneumatic system monitoring - Leak detection - Manufacturing mold pressure control - Pump and compressor control - Liquid level measurement - Oil & gas process control PORTFOLIO Model FP5000 pressure transducers are part of a comprehensive line of Honeywell pressure sensors. ## VALUE TO CUSTOMERS - Built on the Honeywell history of - higher-quality pressure sensing technologies - Next-gen design of the popular FP2000 pressure sensor - Offers more repeatable, reliable, and accurate pressure measurements over time - Rugged, stainless steel pressure sensors are built and tested to perform and survive in many demanding environments - Configurable platform creates a wide range of standard configurations - Stocked components enable shipping within ten business days on most configurations CONFIGURABLE PRESSURE TRANSDUCER, MODEL FP5000 TABLE 1. PERFORMANCE SPECIFICATIONS **==> picture [258 x 183] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Measure<br>Operating pressure Gage: 10 in-H2O [0.36 psi] to 5000 psi<br>ranges Absolute: 5 psi to 5000 psi<br>Vacuum: 10 in-H2O [0.36 psi] to 15 psi<br>Barometric: 0 to 30 in-Hg,<br>16 to 32 in-Hg, 26 to 32 in-Hg<br>Compound ranges available consult<br>factory<br>Equivalent ranges are available in other<br>pressure units also: kPa, bar, mm-Hg,<br>in-Hg, mbar, torr, in-H2O<br>0.2 %FSS BFSL (Standard accuracy)<br>Accuracy [1,7]<br>0.1 %FSS BFSL (High accuracy)<br>0 Vdc to 5 Vdc, 0 Vdc to 10 Vdc, or<br>Output (selectable)<br>4 mA to 20 mA (two wire)<br>Resolution Continuous (Fully analog signal path)<br>**----- End of picture text -----**<br> TABLE 2. ENVIRONMENTAL SPECIFICATIONS **==> picture [258 x 93] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Measure<br>Operating temperature range See Table 3 (Electrical connectors)<br>Compensated temperature See Table 4 (Thermal effects error<br>range band)<br>Thermal effects error band See Table 4 (Thermal effects error<br>(TEB) [2,3] band)<br>Sealing See Table 3 (Electrical connectors)<br>**----- End of picture text -----**<br> Notes: 1. Accuracies stated are with respect to best fit straight line (BFSL) for all errors including linearity, hysteresis, and non-repeatability through zero. 2. Thermal Effects Error Band - The maximum deviation in output due to changes in temperature over the entire compensated temperature range, relative to output measured at reference temperature. Includes all errors due to: Thermal Effect on Offset and Thermal Effect on Span. 3. Thermal effects error band (TEB) increases pro-rata for pressure ranges below 5 psi [0.35 bar]. 4. True Zero Output: The voltage output versions have onboard circuitry that allows the output signal to swing all the way to ground (True Zero) and even a little below (~-0.2 V). This mitigates increased error at lower voltage measurements. 5. Over pressure: The absolute maximum rating for pressure which may be safely applied to the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure to higher pressure may cause permanent damage to the product. 6. Burst pressure: The maximum pressure that may be applied to the product without causing escape of the pressure media. The product should not be expected to function after exposure to any pressure beyond the rated burst pressure. TABLE 3. ELECTRICAL CONNECTORS **==> picture [257 x 102] intentionally omitted <==** **----- Start of picture text -----**<br> Connector Operating Temperature Range Sealing<br>PT-02A-10-6P -40°C to 125°C [-40°F to 250°F] IP67<br>DIN FORM A -40°C to 125°C [-40°F to 250°F] IP65<br>DIN FORM C -40°C to 90°C [-40°F to 194°F] IP65<br>Integral cable -40°C to 105°C [-40°F to 221°F] IP67<br>Conduit fitting -40°C to 105°C [-40°F to 221°F] IP67<br>M12 x 1, 4-pin -40°C to 85°C [-40°F to 185°F] IP67<br>**----- End of picture text -----**<br> TABLE 4. THERMAL EFFECTS ERROR BAND (TEB) **==> picture [257 x 119] intentionally omitted <==** **----- Start of picture text -----**<br> Compensated For Standard For High<br>Temperature Range Accuracy Accuracy<br>0° C to 60° C<br>< ±0.75 %FSS < ±0.5 %FSS<br>[40° F to 140° F]<br>-20° C to 80° C<br>< ±1.5 %FSS < ±1 %FSS<br>[0° F to 180° F]<br>-40° C to 85° C<br>< ±2.25 %FSS < ±1.5 %FSS<br>[-40° F to 185° F]<br>-40° C to 125° C<br>< ±2.25 %FSS < ±1.5 %FSS<br>[-40° F to 250° F]<br>**----- End of picture text -----**<br> ## TABLE 5. MECHANICAL SPECIFICATIONS **==> picture [257 x 280] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Measure<br>Media Gas, liquid<br>Over pressure [5]<br>Operating ranges<br>6X FS<br>≤ 15 psi (1 bar):<br>15 psi (1 bar)<br>< Operating ranges 4X FS<br>≤ 1000 psi (70 bar):<br>1000 psi (70 bar)<br>3X FS or 10000 psi (700 bar)<br>< Operating ranges<br>whichever is less<br>≤ 5000 psi (350 bar):<br>Burst pressure [6]<br>Operating ranges<br>10X FS<br>≤ 15 psi (1 bar):<br>15 psi (1 bar)<br>< Operating ranges 6X FS<br>≤ 1000 psi (70 bar):<br>1000 psi (70 bar)<br>4X FS or 10000 psi (700 bar)<br>< Operating ranges<br>whichever is less<br>≤ 5000 psi (350 bar):<br>Weight (approx.) 150 g [5.3 oz]<br>Wetted parts material Ha C276 and 316L stainless steel<br>Labels Laser engraved<br>**----- End of picture text -----**<br> 7. All specifications apply at 25°C [77°F] and under operating conditions unless otherwise noted. 8. Full Scale Span (FSS): The algebraic difference between output signal measured at the upper and lower limits of the operating pressure range. Also known as “span”. 9. Offset: The output signal obtained when the reference pressure is applied to all available pressure ports. Also known as “null” or “zero”. 10. Reference pressure: The pressure used as a reference (zero) in measuring product performance. Unless otherwise specified, this is vacuum (0 psia) for absolute pressure sensors and local ambient atmospheric pressure (0 psig) for gage/vacuum pressure sensors. 11. Minimum operating pressure: The lower limit of the operating pressure range. 2 sensing.honeywell.com CONFIGURABLE PRESSURE TRANSDUCER, MODEL FP5000 ## TABLE 6. ELECTRICAL SPECIFICATIONS[7] **==> picture [525 x 257] intentionally omitted <==** **----- Start of picture text -----**<br> Specifications 2AM, 2AR: 2AN: 2AP:<br>4 mA to 20 mA (2 wire) 0 V to 5 V (3 wire) [4] 0 V to 10 V (3 wire) [4]<br>Supply voltage 9 Vdc to 28 Vdc 9 Vdc to 28 Vdc 14 Vdc to 28 Vdc<br>Current consumption 4 mA to 24 mA < 6 mA < 6 mA<br>Output at reference pressure [10] -<br>(absolute, gage, vacuum)<br>Output at minimum operating 4 mA ±0.5 %FSS 0 V ±0.5 %FSS 0 V ±0.5 %FSS<br>pressure [11] - (compound,<br>barometric)<br>Full scale span (FSS) [8] 16 mA ±1 %FSS 5 V ±1 %FSS 10 V ±1 %FSS<br>Frequency response 3500 Hz 3500 Hz 3500 Hz<br>Reverse voltage protection Yes, 28 V Yes, 28 V Yes, 28 V<br>< 950 Ohm at 28 V decreasing<br>Load impedance > 10K Ohms > 10K Ohms<br>linearly to 0 Ohm at 9 V<br>Insulation resistance >500 MOhm to case GND at 33 V >500 MOhm to case GND at 33 V >500 MOhm to case GND at 33 V<br>Overvoltage protection >32 V >32 V >32 V<br>Power up time < 1 sec < 1 sec < 1 sec<br>Yes, > ±5 %FS adjustment, Yes, > ±5 %FS adjustment, Yes, > ±5 %FS adjustment,<br>Zero adjustment potentiometer accessible from top after accessible from top after accessible from top after<br>demounting connector demounting connector demounting connector<br>**----- End of picture text -----**<br> Sensing and Internet of Things 3 ## CONFIGURABLE PRESSURE TRANSDUCER, MODEL FP5000 ## TABLE 7. DIN FORM A (6M), DIN FORM C (6BO) WIRING **==> picture [525 x 112] intentionally omitted <==** **----- Start of picture text -----**<br> STANDARD ALTERNATIVE<br>4 mA to 20 mA 0 V to 5 V/0 V to 10 V 4 mA to 20 mA 0 V to 5 V/0 V to 10 V<br>PIN (2AM, 2AR) (2AN, 2AP) (2AM, 2AR) (2AN, 2AP)<br>Designation Designation Designation Designation<br>1 (+) Supply (+) Supply (+) Supply (+) Supply<br>2 (+) Output (+) Output (+) Output Supply return/ (-) Output<br>3 No connection Supply return/ (-) Output No connection (+) Output<br>E No connection No connection Case GND Case GND<br>**----- End of picture text -----**<br> ## TABLE 8. PT02A-10-6P, 6-PIN (6A) WIRING **==> picture [524 x 140] intentionally omitted <==** **----- Start of picture text -----**<br> STANDARD ALTERNATIVE<br>4 mA to 20 mA 0 V to 5 V/0 V to 10 V 4 mA to 20 mA 0 V to 5 V/0 V to 10 V<br>PIN (2AM, 2AR) (2AN, 2AP) (2AM, 2AR) (2AN, 2AP)<br>Designation Designation Designation Designation<br>A (+) Supply (+) Supply (+) Supply (+) Supply<br>B No connection Supply return (+) Output (+) Output<br>C No connection (-) Output No connection No connection<br>D (+) Output (+) Output No connection Supply return/ (-) Output<br>E No connection No connection No connection No connection<br>F No connection No connection No connection No connection<br>**----- End of picture text -----**<br> ## TABLE 9. INTEGRAL CABLE (6Q), CONDUIT FITTING (6R) WIRING **==> picture [524 x 113] intentionally omitted <==** **----- Start of picture text -----**<br> STANDARD ALTERNATIVE<br>4 mA to 20 mA 0 V to 5 V/0 V to 10 V 4 mA to 20 mA 0 V to 5 V/0 V to 10 V<br>PIN (2AM, 2AR) (2AN, 2AP) (2AM, 2AR) (2AN, 2AP)<br>Designation Designation Designation Designation<br>Red (+) Supply (+) Supply (+) Supply (+) Supply<br>Black (+) Output Supply return Not available Supply return/ (-) Output<br>Green Not available (-) Output Not available Not available<br>White Not available (+) Output (+) Output (+) Output<br>**----- End of picture text -----**<br> ## TABLE 10. M12 X 1, 4-PIN (6BJ) WIRING **==> picture [524 x 112] intentionally omitted <==** **----- Start of picture text -----**<br> STANDARD ALTERNATIVE<br>4 mA to 20 mA 0 V to 5 V/0 V to 10 V 4 mA to 20 mA 0 V to 5 V/0 V to 10 V<br>PIN (2AM, 2AR) (2AN, 2AP) (2AM, 2AR) (2AN, 2AP)<br>Designation Designation Designation Designation<br>1 (+) Supply (+) Supply (+) Supply (+) Supply<br>2 No connection (+) Output (+) Output No connection<br>3 (+) Output Supply return/ (-) Output No connection Supply return/ (-) Output<br>4 Case GND Case GND Case GND (+) Output<br>**----- End of picture text -----**<br> TABLE 11. INTRINSICALLY SAFE APPROVALS FOR OPTION 2AR (NOT AVAILABLE ON 2AM, 2AN, 2AP) **==> picture [522 x 99] intentionally omitted <==** **----- Start of picture text -----**<br> Agency Approvals<br>Class I, Div 1, Groups A, B, C, D<br>cFMus Class I, Zone 0, AEx/Ex ia IIC T4/T5 Ga<br>Ta= -40°C to 40°C (T5), -40°C to 85°C (T4)<br>II 1 G Ex ia IIC T4/T5 Ga<br>ATEX<br>Ta= -40°C to 40°C (T5), -40°C to 85°C (T4)<br>Ex ia IIC T4/T5 Ga<br>IEC Ex<br>Ta= -40°C to 40°C (T5), -40°C to 85°C (T4)<br>**----- End of picture text -----**<br> _See Honeywell’s website (http://sensing.honeywell.com) for up-to-date information regarding intrinsically safe approvals. Refer to Installation manual #008-0751-00 for installation/wiring instructions, cautions and warnings._ 4 sensing.honeywell.com ## CONFIGURABLE PRESSURE TRANSDUCER, MODEL FP5000 |Figure 1. Product Nomenclature| |---| |NF G 1 BR 1AK 2AM 5F 6M 7BA<br>,<br>,<br>,<br>,<br>,| |Product Series<br>Type<br>NF FP5000 pressure transducer<br>G Gage<br>A Absolute<br>V Vacuum<br>B Barometric (UG, UQ, UR only)<br>C Compound (consult factory)<br>_psi_<br>AN*<br>AP*<br>AT<br>AV<br>BJ<br>BL<br>BM<br>BN<br>BP<br>BR<br>CJ<br>CL<br>CN<br>CP<br>CQ<br>CR<br>CS<br>CT<br>CV<br>DJ<br>DL<br>DM<br>DN<br>DR<br>0.5 psi<br>1 psi<br>5 psi<br>10 psi<br>15 psi<br>25 psi<br>30 psi<br>50 psi<br>75 psi<br>100 psi<br>150 psi<br>200 psi<br>250 psi<br>300 psi<br>400 psi<br>500 psi<br>600 psi<br>750 psi<br>1000 psi<br>1500 psi<br>2000 psi<br>2500 psi<br>3000 psi<br>5000 psi<br>_bar_<br>ME<br>MF<br>NA<br>MG<br>NB<br>MH<br>MI<br>MJ<br>NC<br>MK<br>ND<br>ML<br>NE<br>MY<br>NG<br>1 bar<br>2 bar<br>3.5 bar<br>5 bar<br>7 bar<br>10 bar<br>20 bar<br>30 bar<br>35 bar<br>50 bar<br>70 bar<br>100 bar<br>135 bar<br>200 bar<br>350 bar<br>_kPa_<br>35 kPa<br>100 kPa<br>200 kPa<br>300 kPa<br>700 kPa<br>1000 kPa<br>1500 kPa<br>3000 kPa<br>5000 kPa<br>7000 kPa<br>10000 kPa<br>_in-Hg_<br>UG<br>UQ<br>UR<br>30 in-Hg<br>16-32 in-Hg<br>26-32 in-Hg<br>_in-H2O_<br>WA*<br>WC*<br>WE*<br>WG*<br>10 in-H2O<br>20 in-H2O<br>30 in-H2O<br>50 in-H2O<br>Range<br>Temperature Compensation<br>1AK 0°C to 60°C [40°F to 140°F]<br>1Y1<br>-20°C to 80°C [0°F to 180°F]<br>1AP1 -40°C to 85°C [-40°F to 185°F]<br>1BA2 -40°C to 125°C [-40°F to 250°F]<br>Output<br>2AM 4 mA to 20 mA<br>2AN 0 Vdc to 5 Vdc<br>2AP 0 Vdc to 10 Vdc<br>2AR 4 mA to 20 mA Intrinsically Safe<br>(see Table 11 for certifications)<br>Pressure Port<br>5A<br>1/4-18 NPT female<br>5B<br>1/4-18 NPT male<br>5D<br>7/16-20 UNF male<br>5F<br>G1/4 B female<br>5G<br>G1/4 B male<br>5P<br>M12 x 1.5 male<br>5AE 1/2-14 NPT male<br>5I<br>1/8-27 NPT male<br>Electrical Connection<br>6A<br>PT02A-10-6P, 6-pin<br>6M<br>DIN A 43650, 4-pin<br>6BO DIN C, 4-pin<br>6Q<br>Integral cable, 5 feet#<br>6R<br>Conduit fitting with 5 feet#cable<br>6BJ<br>M12 x 1 (IEC 61076-2-101 style AM), 4-pin<br>Wiring<br>7BA Standard<br>7BB Alternative<br>Calibration<br> <br>5-point calibration at 77°F<br>9A<br>9-point calibration at 77°F<br>_1 1Y and 1AP not available for pressure ranges below 5 psi [0.35 bar]_<br>_2 1BA not available for pressure ranges below 50 psi [3.5 bar]_<br>KD<br>KF<br>KG<br>KH<br>KJ<br>KL<br>KM<br>KQ<br>KR<br>KS<br>KT<br>Accuracy<br>1 0.10 %*<br>2 0.20 %<br>_More ranges are available._<br>_Please consult Honeywell for options._<br>_* Not available in absolute pressure type_<br>_Ranges with blue highlight (greater than 100 kPa, 15 psi, 1 bar)_<br>_are NOT available in Vacuum._<br>_#Consult factory for other cable lengths_<br>_*Not available in ranges < 2 psi_<br>SAMPLE CATALOG LISTINGS<br>Order Code<br>Description<br>NFA1BM,1AK,2AP,5A,6A,7BA<br>Model FP5000; 0.10% accuracy; 30 psi absolute;<br>compensated across 0°C to 60°C [40°F to 140°F];<br>0 Vdc to 10 Vdc output; 1/4-18 NPT female port;<br>PT02A-10-6P 6-pin electrical connector; standard wiring<br>NFG2DR,1Y,2AR, 5G,6Q,7BB<br>Model FP5000; 0.20% accuracy; 5000 psi gage;<br>compensated across -20°C to 80°C [0°F to 180°F];<br>Intrinsically Safe 4 mA to 20 mA output; G 1/4 B male port;<br>5 ft long integral cable; alternative wiring~~E~~| Sensing and Internet of Things 5 ## CONFIGURABLE PRESSURE TRANSDUCER, MODEL FP5000 Figure 2. Mounting Dimensions ## **ELECTRICAL TERMINATION** **==> picture [526 x 296] intentionally omitted <==** **----- Start of picture text -----**<br> Code 6BO: 4-pin, Code 6M: 4-pin, Code 6A: 6-pin, Code 6Q: 4-conductor, vented, Code 6R: 4-conductor, vented, Code 6BJ: 4-pin M12 x 1<br>Micro DIN Form C Standard DIN 43650 Form A Bendix connector Integral cable 1/2-14 NPT conduit exit with (IEC 61076-2-101) style AM<br>integral cable<br>Ø 31,8<br>[1.3] Ø 31,8 Ø 31,8 Ø 31,8<br>[1.3] [1.3] [1.3]<br>[1.1]26,0 [0.4]10,4 [0.3]7,9 [0.7]18,2 [0.3]8,8 [0.8]21,3 [0.4]10,4 [1.4]35,8 [1.6]41,1 [0.4]10,4 [1.1]27,2<br>Ø 25,0<br>[1.0]<br>Ø 31,8[1.3] Ø 25,0[1.0]<br>Ø 25,0 Choose from<br>[1.0] electrical termination code: 6BO, 6M, 6A, 6Q, 6BJ & 6R<br>8,8 [0.3]<br>37,1 37,1<br>[1.5] [1.5]<br>22,2 22,2<br>[0.9] [0.9]<br>Choose from<br>Choose from pressure ports: 16,8 pressure ports:<br>PRESSURE Codes 5F or 5A [0.7] Codes 5AE, 5G, 5P, 5B, 5D, or 5I<br>PORTS<br>Code 5F: G 1/4 B Code 5A: 1/4-18 NPT Code 5G: G 1/4 B male Code 5B: 1/4-18 NPT Code 5D: 7/16-20 UNF Code 5AE: 1/2-14 NPT Code 5P: M12 x 15 male Code 5I: 1/8-27 NPT<br>female female male male male male<br>[0.6]15,1 [0.7]18,4 [0.7]16,8 [0.7]18,0 [0.6]15,2 [0.5]13,2<br>22,2<br>[0.9] 22,2<br>[0.9]<br>**----- End of picture text -----**<br> 6 sensing.honeywell.com ## , CAUTION PRODUCT DAMAGE DUE TO MECHANICAL ISSUES - Ensure torque specifications are determined for the specific application. (Mating materials and thread sealants can result in significantly different torque values from one application to the next.) - When using mating parts made of stainless steel, use a thread sealant with anti-seize properties to prevent thread galling. Ensure the sealant is rated for the application. - Use appropriate tools (such as an open-ended wrench or deep-well socket) to install transducers. - Always hand-start transducers into the hole to prevent cross threading and damage. - Ensure that torque is not applied to the electrical connector. - Ensure that the proper mating electrical connector with a seal is used to connect the transducer. Improper or damaged seals can compromise ingress protection, leading to short circuits. - To ensure proper environmental sealing and electrical connections when using a connector, follow the connector manufacturer’s installation guidelines. - All terminal cavities must be sealed using the correct wire gauge and seal combination. - If only two leads are used, any additional terminal cavities should be sealed per the connector manufacturer’s installation guide. - Honeywell recommends using a crimping tool for crimping wires to the connector terminals. - Contact the individual connector manufacturer for connector wiring. Failure to comply with these instructions could result in product damage. ## , NOTICE Refer installation manual #008-0751-00 for installation/ wiring instructions, cautions and warnings related to Intrinsically Safe FP5000 (option 2AR). ## FOR MORE INFORMATION Honeywell Sensing and Internet of Things services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing, or the nearest Authorized Distributor, visit sensing.honeywell.com or call: ## m WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. ## m WARNING ## MISUSE OF DOCUMENTATION - The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. - Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. ## Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While Honeywell may provide application assistance personally, through our literature and the Honeywell website, it is buyer’s sole responsibility to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use. USA/Canada +302 327 8920 Latin America +1 305 805 8188 Europe +1 302 327 8920 Japan +81 (0) 3-6730-7152 Singapore +65 6355 2828 Greater China +86 4006396841 Honeywell Sensing and Internet of Things 830 East Arapaho Road Richardson, TX 75081 Hastelloy® is a registered trademark of Haynes International, Inc. 008927-2-EN | 2 | 06/20 © 2020 Honeywell International Inc.
Updated at February 9, 2023
Honeywell is a globally recognized leader in the design and manufacture of advanced sensing and switching solutions. Renowned for engineering components that deliver enhanced precision and ruggedness, Honeywell provides essential technologies for demanding applications across critical healthcare, aerospace, and industrial equipment. With a comprehensive portfolio built to address both basic and complex design challenges, the company stands at the forefront of reliable electronic component manufacturing. The core of our Honeywell offering is an extensive selection of high-performance sensors and transducers. This includes a robust lineup of pressure sensors and transducers engineered for accurate fluid and gas measurement in challenging environments. Furthermore, we provide a wide array of temperature sensors and specialized temperature sensing NTC thermistors designed for stable thermal management, alongside precision current sensors and load cells that deliver critical feedback for control systems. Beyond advanced sensing technology, Honeywell’s expertise extends to essential circuit protection and electromechanical components. Our selection encompasses power relays, thermal magnetic circuit breakers, and standard terminal blocks, ensuring safe and efficient power distribution. Whether integrating core components or sourcing specialized accessories, design engineers can rely on Honeywell for uncompromising quality and operational excellence.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →