Image not available
Illustrative purposes only
05626
Relay Accessory, Mounting Adapter, Finder 56.32 Miniature Power Relay, 56 Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: FINDER
- Product type: Other Relay Accessories
- Accessory Type:Mounting Adapter; For Use With:Finder 56.32 Miniature Power Relay; Product Range:56 Series; SVHC:No SVHC (15-Jan-2019)
- SVHC: No SVHC (04-Feb-2026)
- For Use With: Finder 56.32 Miniature Power Relay
- Product Range: 56 Series
- Accessory Type: Mounting Adapter
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 1.08 € |
| Current stock | 10+ |
| Lead time | 30 days |
**56 SЕRIES** ## Miniature power relays 12 A Industrial furnaces and ovens Control and management of electric power Industrial motors Circuit breakers and switches Panels for electrical distribution Control panels Carousel warehouses **==> picture [34 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Vending<br>machines<br>**----- End of picture text -----**<br> **56 SERIES** **A** ## **Plug-in - 12 A Power relay, 2 & 4 pole** ## **56.32/56.34** ## **56.32-0300** - Flange mount option - (Faston 187, 4.8 x 0.5 mm termination) - AC coils & DC coils - Lockable test button and mechanical flag indicator - Cadmium Free contacts (standard version) - Contact material options - 96 series sockets - Coil EMC suppression - Accessories - European Patent - 2 or 4 pole changeover contact - Plug-in/Faston 187 - 2 pole normally open contact (≥ 1.5 mm gap) - Plug-in/Faston 187 - For 4 CO (4PDT) only. _For UL ratings see:_ _“General technical information” page_ V **==> picture [487 x 402] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||||||| |---|---|---|---|---|---|---|---|---|---| |56.32|56.34|56.32-0300| |For outline drawing see page 8| |Contact specification| |Contact configuration|2 CO (DPDT)|4 CO (4PDT)|2NO (DPST-NO) - ≥ 1.5 mm gap| |Rated current/Maximum peak current|A|12/20|12/20| |Rated voltage/| |Maximum switching voltage|V AC|250/400|250/400| |Rated load AC1|VA|3000|3000| |Rated load AC15 (230|V AC)|VA|700|700| |Single phase motor rating (230|V AC)|kW|0.55|0.55| |Breaking capacity DC1: 30/110/220|V|A|12/0.5/0.25|12/1/0.5| |Minimum switching load|mW (V/mA)|500 (10/5)|500 (10/5)| |Standard contact material|AgNi|AgNi| |Coil specification| |Nominal voltage (UN)|V AC (50/60 Hz)|6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*| |V DC|6 - 12 - 24 - 48 - 60 - 110 - 125 - 220|—| |Rated power AC/DC|VA (50 Hz)/W|1.5/1|2/1.3|1.5/—| |Operating range|AC|(0.8…1.1)UN|(0.85…1.1)UN| |DC|(0.8…1.1)UN|(0.8…1.1)UN|—| |Holding voltage|AC/DC|0.8 UN / 0.6 UN|0.85 UN/—| |Must drop-out voltage|AC/DC|0.2 UN / 0.1 UN|0.2 UN/—| |Technical data| |Mechanical life AC/DC|cycles|20 · 10|[6]|/50 · 10|[6]|20 · 10|[6]|/—| |Electrical life at rated load AC1|cycles|100 · 10|[3]|100 · 10|[3]| |Operate/release time|ms|9/6|11/11|8/4| |Insulation between coil| |and contacts (1.2/50 μs)|kV|4|5|4| |Dielectric strength| |between open contacts|V AC|1000|2000| |Ambient temperature range|°C|–40…+70|–40…+70| |Environmental protection|RT I|RT I| |Approvals|(according to type)|C€|@|G|FAL K|B|RINA|As|®| **----- End of picture text -----**<br> **3** **56 SERIES** ## **Printed circuit mount 12 A Power relay** ## **56.42/56.44** ## **56.42-0300** - 2 & 4 pole **A** - AC coils & DC coils - Cadmium Free contacts (standard version) - Contact material option - RT III (wash tight) option available - 2 or 4 pole changeover contact - PCB mount - 2 pole normally open contact (≥ 1.5 mm gap) - PCB mount - For 4 CO (4PDT) only. _For UL ratings see:_ |* For 4 CO (4PDT) only.<br>_For UL ratingsor UL ratings UL ratingsratings see::_|* For 4 CO (4PDT) only.<br>_For UL ratingsor UL ratings UL ratingsratings see::_|Peper|eeceeeeeseteeeseseesseeeeed|eeceeeeeseteeeseseesseeeeed|eeceeeeeseteeeseseesseeeeed||| |---|---|---|---|---|---|---|---| |_“General technical information” page_V||56.42|||56.44||56.42-0300| |||Copper side view||Copper side view|||Copper side view| |For outline drawing see page 8|||||||| |**Contact specification**|||||||| |Contact configuration||2 CO (DPDT)|||4 CO (4PDT)||2NO (DPST-NO) - ≥ 1.5 mmgap| |Rated current/Maximumpeak current<br>A|||12/20||||12/20| |Rated voltage/<br>Maximum switchingvoltage|V AC||250/400||||250/400| |Rated load AC1|VA||3000||||3000| |Rated load AC15 (230 V AC)|VA||700||||700| |Singlephase motor rating(230 V AC)<br>kW|||0.55||||0.55| |BreakingcapacityDC1: 30/110/220 V<br>A||12/0.5/0.25|||||12/1/0.5| |Minimum switchingload|mW (V/mA)|500 (10/5)|||||500 (10/5)| |Standard contact material<br>**Coil specification**|||AgNi||||AgNi| |Nominal voltage (UN)|V AC (50/60 Hz)||6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*|||6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*|| ||V DC|6 - 12 - 24 - 48 - 60 - 110 - 125 - 220|||6 - 12 - 24 - 48 - 60 - 110 - 125 - 220||—| |Ratedpower AC/DC|VA (50 Hz)/W|1.5/1|||2/1.3||1.5/—| |Operating range|AC|(0.8…1.1)UN|||||(0.85…1.1)UN| ||DC|(0.8…1.1)UN|||(0.8…1.1)UN||—| |Holdingvoltage|AC/DC|0.8 UN/ 0.6 U||/ 0.6 UN|||0.85 UN/—| |Must drop-out voltage<br>**Technical data**|AC/DC|0.2 UN/ 0.1 U||/ 0.1 UN|||0.2 UN/—| |Mechanical life AC/DC|cycles|20 · 10|20 · 106/50 · 10|/50 · 106|||20 · 106/—| |Electrical life at rated load AC1|cycles|100 · 103|||||100 · 103| |Operate/release time|ms|9/6|||11/11||8/4| |Insulation between coil|||||||| |and contacts(1.2/50μs)<br>Dielectric strength<br>between open contacts<br>Ambient temperature range<br>Environmentalprotection<br>**Approvals**(according to type)|kV<br>V AC<br>°C|4<br>1000<br>–40…+70<br>RT I<br>@|||5<br>~~FAL &~~|~~B~~|4<br>2000<br>–40…+70<br>RT I<br>®<br>~~RINAcA\is~~| **4** **56 SERIES** **A** ## **Ordering information** Example: 56 series plug-in relay, 2 CO (DPDT), 12 V DC coil, lockable test button and mechanical indicator. **A B C D 5 6 . 3 2 . 9 . 0 1 2 . 0 0 4 0 Series A: Contact material D: Special versions** 0 = Standard AgNi 0 = Standard **Type** 2 = AgCdO 1 = Wash tight (RT III) for 56.42 and 3 = Plug-in 4 = AgSnO2 56.44 only 4 = PCB 6 = Rear flange mount (4 pole only) **B: Contact circuit** 8 = Rear 35 mm rail mount (4 pole **No. of poles** 0 = CO (nPDT) only) 2 = 2 pole, 12 A 3 = NO (nPST), ≥ 1.5 mm For other mounting options see page 9 4 = 4 pole, 12 A contact gap **C: Options Coil version** 0 = None 8 = AC (50/60 Hz) 2 = Mechanical indicator 9 = DC 3* = LED (AC) 4 = Lockable test button + **Coil voltage** mechanical indicator See coil specifications 5* = Lockable test button + LED (AC) - 5* = Lockable test button + LED (AC) 54* = Lockable test button + LED (AC) + mechanical indicator |**Coil voltage**<br>See coil specifications|mechanical indicator<br>5* = Lockable test button + LED (AC)<br>54* = Lockable test button + LED (AC) +<br>mechanical indicator| |---|---| |**Selecting features and options: only combinations in the same row are possible.**|6* = Double LED (DC non-polarized)| |7* = Lockable test button + double<br>LED (DC non-polarized)<br>74* = Lockable test button + double<br>Preferred selections for best availabilityare shown in**bold**.<br>**Type**<br>**Coil version**<br>**A**<br>**B**<br>**C**<br>**D**<br>~~a~~<br>~~a~~|| |LED (DC non-polarized) +<br>mechanical indicator<br>8* = LED + diode (DC, polarity positive<br>to pin 7) for 56.32 only<br>9* = Lockable test button + LED +<br>diode (DC, polarity positive to pin<br>7) for 56.32 only<br>56.32<br>AC<br>**0**- 2 - 4<br>**0**<br>0 - 2 - 3 -**4**- 5<br>**0**<br>AC<br>0 - 2 - 4<br>0<br>54<br>/<br>AC<br>0 - 2 - 4<br>3<br>0 - 3 - 5<br>0<br>DC<br>**0**- 2 - 4<br>**0**<br>0 - 2 -**4**- 6 - 7 - 8 - 9<br>**0**<br>DC<br>0 - 2 - 4<br>0<br>**74 - 94**<br>/<br>~~a~~<br>~~===>~~|| |AC<br>**0**- 2 - 4<br>**0**<br>**0**- 2 - 3 -**4**- 5<br>**0**- 6 - 8|94* = Lockable test button + LED +| |AC<br>0 - 2 - 4<br>0<br>54<br>/|diode (DC, polarity positive to| |56.34<br>DC<br>**0**- 2 - 4<br>**0**<br>**0**- 2 -**4**- 6 - 7<br>**0**- 6 - 8|pin 7) + mechanical indicator for<br>56.32 only| |DC<br>0 - 2 - 4<br>**0**<br>**74**<br>/<br>56.42<br>DC<br>**0**- 2 - 4<br>**0**<br>**0**<br>**0**- 1<br>AC<br>0 - 2 - 4<br>0 - 3<br>0<br>0 - 1<br>56.44<br>AC - DC<br>**0**- 2 - 4<br>**0**<br>**0**<br>**0**- 1<br>~~Co~~<br>~~—~~|* Options not available for 220 V DC and<br>400 V AC versions.| - 9* = Lockable test button + LED + diode (DC, polarity positive to pin 7) for 56.32 only - 94* = Lockable test button + LED + diode (DC, polarity positive to pin 7) + mechanical indicator for 56.32 only ## ~~LT~~ **Special versions for Rail Applications on request** ## **Descriptions: options and special versions** **C: Option 3, 5, 54 C: Option 6, 7, 74** LED (AC) Double LED (DC non-polarized) **C: Option 8, 9, 94** LED + diode (DC, polarity positive to pin 7) - (56.32 only) E **Lockable test button and mechanical flag indicator (0040, 0050, 0054, 0070, 0074, 0090, 3 0094) 1** The dual-purpose Finder test button can be used in two ways: Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state. iF ~~i~~ Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are **2** latched in the operating state, and remain so until the test button is rotated back to its former position. In both cases ensure that the test button actuation is swift and decisive. **5** **56 SERIES** **Technical data** * Only in applications where over voltage category II is permitted. In applications of over voltage category III: Micro-disconnection. **A** |**Insulation according to EN 61810-1**|**Insulation according to EN 61810-1**|**2 CO - 4 CO**|**2 CO - 4 CO**|**2 NO**|**2 NO**| |---|---|---|---|---|---| |Nominal voltage of supplysystem<br>V AC||230/400||230/400|| |Rated insulation voltage<br>V AC||250|400|250|400| |Pollution degree||3|2|3|2| |**Insulation between coil and contact set**|||||| |Type of Insulation||Basic||Basic|| |Overvoltage category||III||III|| |Rated impulse voltage<br>kV(1.2/50μs)||4||4|| |Dielectric strength<br>V AC||2500||2500|| |**Insulation between adjacent contacts**|||||| |Type of insulation||Basic||Basic|| |Overvoltage category||III||III|| |Rated impulse voltage<br>kV(1.2/50μs)||4||4|| |Dielectric strength<br>V AC||2500||2500|| |**Insulation between open contacts**|||||| |Type of disconnection||Micro-disconnection||Full-disconnection*|| |Overvoltage category||—||II|| |Rated impulse voltage<br>kV(1.2/50μs)||—||2.5|| |Dielectric strength<br>V AC/kV(1.2/50μs)||1000/1.5||2000/3|| |**Insulation between coil terminals**|||||| |Rated impulse voltage (surge) differential mode<br>(according to EN 61000-4-5)<br>kV(1.2/50 µs)||4|||| |**Other data**|||||| |Bounce time: NO/NC<br>ms||1/4(2 CO) ,1/7(4 CO)||3/—(normallyopen)|| |Vibration resistance(5…55)Hz: NO/NC<br>g||17/14|||| |Shock resistance|g|20/14|||| |Power lost to the environment|without contact current<br>W|1(56.32,56.42)||1.3(56.34,56.44)|| ||with rated current<br>W|3.8(56.32,56.42)||6.9(56.34,56.44)|| |Recommended distance between relays mounted on PCB<br>mm||≥ 5|||| ## **Contact specification** **F 56 - Electrical life (AC) v contact current** 2 - 4 pole relays **==> picture [514 x 308] intentionally omitted <==** **----- Start of picture text -----**<br> Resistive load - cosφ = 1<br>Inductive load - cosφ = 0.4<br>H 56 - Maximum DC1 breaking capacity H 56 - Maximum DC1 breaking capacity<br>Changeover version Normally open version<br>contacts in series contacts in series<br>DC voltage (V) DC voltage (V)<br>Cycles<br>DC breaking current (A) DC breaking current (A)<br>**----- End of picture text -----**<br> - When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100 · 10[3] can be expected. - In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time of the load will be increased. **6** **56 SERIES** ## **Coil specifications** **DC coil data,** 2 pole relay |Nominal<br>voltage<br>UN|Coil code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Resistance<br>R|Rated coil<br>consumption<br>Iat UN| |---|---|---|---|---|---| |V||V|V|Ω|mA| |6|**9**.006|4.8|6.6|40|150| |12|**9**.012|9.6|13.2|140|86| |24|**9**.024|19.2|26.4|600|40| |48|**9**.048|38.4|52.8|2400|20| |60|**9**.060|48|66|4000|15| |110|**9**.110|88|121|12500|8.8| |125|**9**.125|100|138|17300|7.2| |220|**9**.220|176|242|54000|4| |Nominal<br>voltage<br>UN|Coil code|Operating range<br>Umin*<br>Umax|Operating range<br>Umin*<br>Umax|Resistance<br>R|Rated coil<br>consumption<br>Iat UN(50 Hz)| |---|---|---|---|---|---| |V||V|V|Ω|mA| |6|**8**.006|4.8|6.6|12|200| |12|**8**.012|9.6|13.2|50|97| |24|**8**.024|19.2|26.4|190|53| |48|**8**.048|38.4|52.8|770|25| |60|**8**.060|48|66|1200|21| |110|**8**.110|88|121|3940|12.5| |120|**8**.120|96|132|4700|12| |230|**8**.230|184|253|17000|6| |240|**8**.240|192|264|19100|5.3| * Umin = 0.85 UN for normally open version. **DC coil data,** 4 pole relay |Nominal<br>voltage<br>UN|Coil code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Resistance<br>R|Rated coil<br>consumption<br>Iat UN| |---|---|---|---|---|---| |V||V|V|Ω|mA| |6|**9**.006|4.8|6.6|32.5|185| |12|**9**.012|9.6|13.2|123|97| |24|**9**.024|19.2|26.4|490|49| |48|**9**.048|38.4|52.8|1800|27| |60|**9**.060|48|66|3000|20| |110|**9**.110|88|121|10400|10.5| |125|**9**.125|100|138|14200|8.8| |220|**9**.220|176|242|44000|5| **R 56 - DC coil operating range v ambient temperature** 2 and 4 pole relay **==> picture [209 x 103] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>2<br>**----- End of picture text -----**<br> **1 -** Max. permitted coil voltage. **2 -** Min. pick-up voltage with coil at ambient temperature. **AC coil data,** 4 pole relay **==> picture [252 x 49] intentionally omitted <==** **----- Start of picture text -----**<br> Nominal Coil code Operating range Resistance Rated coil<br>voltage consumption<br>UN Umin Umax R I at UN (50 Hz)<br>V V V Ω mA<br>**----- End of picture text -----**<br> |Nominal<br>voltage<br>UN<br>V|Coil code|Operating range<br>Umin<br>Umax<br>V<br>V|Operating range<br>Umin<br>Umax<br>V<br>V|Resistance<br>R<br>Ω|Rated coil<br>consumption<br>Iat UN(50 Hz)<br>mA| |---|---|---|---|---|---| |6|**8**.006|4.8|6.6|5.7|300| |12|**8**.012|9.6|13.2|22|150| |24|**8**.024|19.2|26.4|81|90| |48|**8**.048|38.4|52.8|380|37| |60|**8**.060|48|66|600|30| |110|**8**.110|88|121|1900|16.5| |120|**8**.120|96|132|2560|13.4| |230|**8**.230|184|253|7700|9| |240|**8**.240|192|264|10000|7.5| |400|**8**.400|320|440|26000|4.9| **R 56 - AC coil operating range v ambient temperature** 2 pole relay **==> picture [210 x 102] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>normally open version<br>2<br>changeover version 2<br>**----- End of picture text -----**<br> **R 56 - AC coil operating range v ambient temperature** 4 pole relay **==> picture [209 x 102] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>changeover version 2<br>**----- End of picture text -----**<br> **1 -** Max. permitted coil voltage. **2 -** Min. pick-up voltage with coil at ambient temperature. **7** **56 SERIES** **A** ## **Outline drawings** Types 56.32/32-0300 **==> picture [44 x 67] intentionally omitted <==** **==> picture [91 x 46] intentionally omitted <==** Types 56.42/42-0300 **==> picture [151 x 81] intentionally omitted <==** Type 56.34 **==> picture [122 x 76] intentionally omitted <==** Type 56.44 **==> picture [105 x 77] intentionally omitted <==** **8** **56 SERIES** **==> picture [62 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> Accessories<br>**----- End of picture text -----**<br> **==> picture [451 x 727] intentionally omitted <==** **----- Start of picture text -----**<br> Top flange mount adaptor for 56.32 056.25<br>aS 22 . 7 3 . 6<br>T n, A |<br>: : 4 s t D N | 2 =| = j<br>v = | g Sn won)<br>056.25 056.25 with relay | —<br>PaL A s | 3.5 34 . 3 17 Ps| |<br>056.25 056.25 with relay<br>= Rear flange mount adaptor for 56.32 056.26<br>30.4 3 . 7 30 .<br>t+<br>ey<br>.<br>056.26 056.26 with relay<br>— |<br>ine H<br>oO<br>22 . 7 22 . 7<br>056.26 056.26 with relay<br>Top 35 mm rail (EN 60715) adaptor for 56.32 056.27<br>22 . 7 4 4<br>| =[r—T ~~r e= SD4<br>$5 8 a [==] 8<br>056.27 056.27 with relay /—\ 1 ®| |<br>oc} CT f<br>15 3 . 5 34 . 3 7 . 8 o ar ,<br>056.27 056.27 with relay<br>Top flange mount adaptor for 56.34 056.45<br>42 . 8 3 . 6<br>=|— &<br>— : m 2) FOISISIE<br>056.45 056.45 with relay * * "| fi © tf<br>28 3 . 5 34.3 1 . 7 28<br>056.45 056.45 with relay<br>Top 35 mm rail (EN 60715) adaptor for 56.34 056.47<br>15 4 1<br>© [ J ]<br>-<br>L<br>O o<br>=" OG 3 2 7] I N<br>f r ES=s] ,<br>N I N °<br>056.47 056.47 with relay | |<br>! i j SS t<br>ss | u s| 7 8 t+ N<br>056.47 056.47 with relay<br>aoe | 4 tf t4 Sheet of marker tags for relay type 56.34, plastic, 48 tags, 6 x 12 mm, for<br>ett4 be}tH best4 Pieste CEMBRE thermal transfer printers | 060.48<br>we tH ed te<br>et 4 4 ro<br>4 tH tf te<br>co co ce<br>es se es<br>060.48<br>I-2019, www.findernet.com<br>**----- End of picture text -----**<br> **==> picture [10 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> A<br>**----- End of picture text -----**<br> **9** **56 SERIES** **A** |**Screw terminal (Box clamp) socket**<br>panel or 35 mm rail mount (EN 60715)<br>For relay type<br>**Accessories**<br>Metal retaining clip<br>(supplied with socket -packagingcode SMA)|**96.02**<br>**Blue**<br>**96.02.0**<br>**Black**<br>**96.04**<br>**Blue**<br>**96.04.0**<br>**Black**<br>56.32<br>56.34<br>094.71<br>096.71|**96.02**<br>**Blue**<br>**96.02.0**<br>**Black**<br>**96.04**<br>**Blue**<br>**96.04.0**<br>**Black**<br>56.32<br>56.34<br>094.71<br>096.71|**96.02**<br>**Blue**<br>**96.02.0**<br>**Black**<br>**96.04**<br>**Blue**<br>**96.04.0**<br>**Black**<br>56.32<br>56.34<br>094.71<br>096.71|**96.02**<br>**Blue**<br>**96.02.0**<br>**Black**<br>**96.04**<br>**Blue**<br>**96.04.0**<br>**Black**<br>56.32<br>56.34<br>094.71<br>096.71| |---|---|---|---|---| |Plastic retaining and release clip<br>(supplied with socket -packagingcode SPA)|094.91.3|094.91.30<br>~~ee~~|094.91.30<br>—<br>~~ee~~<br>~~ee~~|—<br>~~ee~~| |6-way jumper link<br>~~ee~~<br>~~Po~~|094.06<br>~~ee~~<br>~~Po~~|094.06.0<br>~~ee~~<br>~~ee~~<br>~~Po~~|094.06.0<br>—<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~Po~~|—<br>~~ee~~| |Identification tag<br>~~ee~~<br>~~Po~~|095.00.4<br>~~ee~~<br>~~ee~~<br>~~Po~~||090.00.2<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~Po~~|| |Modules(see table below)|99.02|||| |Timer modules(see table below)|86.30||86.00,86.30|| |Sheet of marker tags for retaining and release clip<br>094.91.3, plastic, 48 tags, 6 x 12 mm, for CEMBRE<br>thermal transfer printers<br>**Technical data**<br>Rated values|060.48<br>—<br>12 A - 250 V|||| |Dielectric strength|2 kV AC|||| |Protection category|IP 20|||| |Ambient temperature<br>°C <br>~~Po~~|–40…+70(see diagram L96)<br>~~Po~~|||| |Screw torque<br>Nm <br>~~Po~~|0.8<br>~~Po~~|||| |Wire striplength<br>mm <br>~~Po~~|8<br>~~Po~~|||| |Max. wire size for 94.02/04 sockets<br>mm2 <br>AWG <br>~~Po~~<br>~~PO~~<br>~~|~~|solid wire<br>~~Po~~||stranded wire<br>~~Po~~|| ||1 x 6 / 2 x 2.5<br>~~Po~~<br>~~PO~~<br>~~|~~||1 x 4 / 2 x 2.5<br>~~Po~~<br>~~PO~~|| ||1 x 10 / 2 x 14<br>~~Po~~<br>~~|~~||1 x 12 / 2 x 14<br>~~Po~~|| ## **L 96 - Rated current v ambient temperature** a ~~es~~ io ~~a~~ aaai ~~OO~~ a 4] ['s 96.02 96.02 96.04 96.04 **6-way jumper link** for 96.02 socket 094.06 (blue) 094.06.0 (black) Rated values 10 A - 250 V ~~sT~~ yyy ~~e8Bs Qt F—c_~~ 0.75 26.3 27 27 27 26.3 **86 series timer modules** Multi-voltage: (12…240)V AC/DC; Multi-functions: AI, DI, SW, BE, CE, DE, EE, FE; (0.05 s…100 h) 86.00.0.240.0000 (12…24)V AC/DC; Bi-function: AI, DI; (0.05 s…100 h) 86.30.0.024.0000 (110…125 ~~pp tp~~ )V AC; Bi-function: AI ~~tt pt~~ , DI; (0.05 s…100 h) ~~8~~ 86.30.8.120.0000 (230…240)V AC; Bi-function: AI, DI; (0.05 s…100 h)0.05 s…100 h) 86.30.8.240.0000 Approvals (according to type): E **094.06** aL **86.00** =a **86.30** > , DI; ~~CE~~ DI;; (0.05 s…100 h)0.05 s…100 h) ~~EAL AYis~~ ) |Diode(+A1,standardpolarity)<br>(6…220)V DC <br>~~CEEALAYis~~|99.02.3.000.00| |---|---| |LED<br>(6…24)V DC/AC <br>~~CEEALAYis~~|99.02.0.024.59| |LED<br>(28…60)V DC/AC <br>~~CE EAL AYis~~|99.02.0.060.59| |LED<br>(110…240)V DC/AC|99.02.0.230.59| |LED + Diode(+A1,standardpolarity)<br>(6…24)V DC|99.02.9.024.99| |LED + Diode(+A1,standardpolarity)<br>(28…60)V DC|99.02.9.060.99| |LED + Diode(+A1,standardpolarity)<br>(110…220)V DC|99.02.9.220.99| |LED + Varistor<br>(6…24)V DC/AC|99.02.0.024.98| |LED + Varistor<br>(28…60)V DC/AC|I-2019, www.findernet.com<br> 99.02.0.060.98| |LED + Varistor<br>(110…240)V DC/AC|I-2019, www.findernet.com<br> 99.02.0.230.98| |RC circuit<br>(6…24)V DC/AC|I-2019, www.findernet.com<br> 99.02.0.024.09| |RC circuit<br>(28…60)V DC/AC|I-2019, www.findernet.com<br> 99.02.0.060.09| |RC circuit<br>(110…240)V DC/AC|I-2019, www.findernet.com<br> 99.02.0.230.09| |Residual current by-pass<br>(110…240)V AC|I-2019, www.findernet.com<br> 99.02.8.230.07| **99.02** Approvals (according to type): DC Modules with non-standard polarity (+A2) on request. **10** **56 SERIES** |**Screw terminal (Plate clamp) socket**<br>panel or 35 mm rail (EN 60715) mount<br>For relay type<br>**Accessories**<br>Metal retaining clip<br>supplied with socket -packagingcode SMA)|**96.72**<br>**Blue**<br>**96.72.0**<br>**Black**<br>**96.74**<br>**Blue**<br>**96.74.0**<br>**Black**<br>56.32<br>56.34<br>094.71<br>096.71|**96.72**<br>**Blue**<br>**96.72.0**<br>**Black**<br>**96.74**<br>**Blue**<br>**96.74.0**<br>**Black**<br>56.32<br>56.34<br>094.71<br>096.71| |---|---|---| |Modules (see table below)<br>**Technical data**<br>Rated values|99.01<br>12 A - 250 V|| |Dielectric strength|2 kV AC|| |Protection category|IP 20|| |Ambient temperature<br>Screw torque<br>©|°C –40…+70<br>Nm0.8|| |Screw torque<br>Wire striplength<br>©|Nm 0.8<br>mm 10|| |Max. wire size for 96.72 and 96.74 sockets|solid wire<br>mm2 1 x 4 / 2 x 4<br>~~Po~~<br>~~PO~~|stranded wire| |||1 x 4 / 2 x 2.5| ||AWG 1 x 12 / 2 x 12<br>~~PO~~|1 x 12 / 2 x 14| **A** 96.72 96.74 ## **99.01 coil indication and EMC suppression modules** for types 96.72 and 96.74 sockets ||||**Blue***| |---|---|---|---| ||Diode(+A1,standardpolarity)|(6…220)V DC|99.01.3.000.00| ||Diode(+A2,non-standardpolarity)|(6…220)V DC|99.01.2.000.00| ||LED|(6…24)V DC/AC|99.01.0.024.59| |**99.01**|LED|(28…60)V DC/AC|99.01.0.060.59| |Approvals<br>(according to type):|LED<br>LED + Diode(+A1,standardpolarity)|(110…240)V DC/AC <br>(6…24)V DC|99.01.0.230.59<br> 99.01.9.024.99| ||LED + Diode(+A1,standardpolarity)|(28…60)V DC|99.01.9.060.99| ||LED + Diode(+A1,standardpolarity)|(110…220)V DC|99.01.9.220.99| ||LED + Diode(+A2,non-standardpolarity)|(6…24)V DC|99.01.9.024.79| |* Modules in Black|LED + Diode(+A2,non-standardpolarity)|(28…60)V DC|99.01.9.060.79| |housing are available on|LED + Diode (+A2, non-standardpolarity)|(110…220)V DC|99.01.9.220.79| |request.|LED + Varistor|(6…24)V DC/AC|99.01.0.024.98| |Green LED is standard.|LED + Varistor|(28…60)V DC/AC|99.01.0.060.98| |Red LED available on|LED + Varistor|(110…240)V DC/AC|99.01.0.230.98| |request.|RC circuit|(6…24)V DC/AC|99.01.0.024.09| ||RC circuit|(28…60)V DC/AC|99.01.0.060.09| ||RC circuit|(110…240)V DC/AC|99.01.0.230.09| ||Residual current by-pass|(110…240)V AC|99.01.8.230.07| **11** **56 SERIES** **==> picture [10 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> A<br>**----- End of picture text -----**<br> **==> picture [486 x 341] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |PCB socket|96.12|96.12.0|96.14|96.14.0| |(blue)|(blue)|(blue)|(blue)| |For relay type|56.32|56.34| |96.12|Accessories| |Approvals|094.51| |(according to type):|Technical data| |®|Rated values|15 A - 250 V| |Dielectric strength|2 kV AC| |Protection category|IP 20| |Ambient temperature|°C|–40…+70| |P1021.5|,|21.5|45|4143| |--f--=b.|id)| |io|ot|o|og| |iQ|1+|+|te|1.|q|q|1| |121|222|a|e|'|¢|o|s|g)]|oO|Oo|~| |143,|244,|>|e+e|Ol|in| |115|216|1|16.6|||'|—_|igs| |Copper s|i|de view| |i|\*"| |96.12| |10,|4110|.|5,|10|||41.5|4.5|14.3| |popoccbeccie|a|ese|scse||=| |wt|&|&|6|Ot|Q|00|5| |ie)|1|oe|@|@|$4+—St|oO|0|4|oe| |1216]|||2224]|] 3236]|| 4244]|©|>|eo|@¢|et|2|%|&@|0|O|O|OO}|a| |14591|| 24601|||34791|||448,|>|ot|s|in||im| |119|2110|| 3414|| 4112|1|!|—| |ia|“y| |Copper side view| |96.14| **----- End of picture text -----**<br> ## **Packaging codes** ## **How to code and identify retaining clip and packaging options for sockets.** Example: **==> picture [335 x 132] intentionally omitted <==** **----- Start of picture text -----**<br> 9 6 . 7 4 S M A<br>A Standard packaging<br>SM Metal retaining clip<br>SP Plastic retaining clip<br>9 6 . 7 4 Without retaining clip<br>**----- End of picture text -----**<br> **9 6 . 7** Please see general technical information **12**
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →