0258260000
END AND INTERMEDIATE PLATE
- Manufacturer: WEIDMULLER
- Product type: Terminal Block Accessories
- For Use With:Weidmuller Terminal Blocks; Accessory Type:End & Intermediate Plate; Product Range:- 14C0417
- For Use With: Weidmuller Terminal Blocks
- Product Range: -
- Accessory Type: End & Intermediate Plate
| Delivery and price | |
|---|---|
| Units per pack | 1000 |
| Price | 1.78 € |
| Current stock | 100+ |
| Lead time | 30 days |
**A**
**B**
**C**
**D**
**E**
**F**
**G**
**H**
**I**
**J**
## **SAK-Series**
**SAK-Series TS 35**
## SAK-Series
**==> picture [35 x 165] intentionally omitted <==**
**SAK-Series TS 32**
**SAK-Series combination foot TS 35 + TS 32**
## **SAK-Series for special applications**
**AKZ-Series TS 15**
**Multi-pole terminal strips**
**KLBÜ shielded connection**
**Busbars / Terminal rails**
**Accessories**
**Tools and ferrules**
**Marking systems**
## **Technical appendix**
## **Index**
Search according to type or order number, Addresses worldwide
**K**
**W**
**==> picture [36 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
X<br>**----- End of picture text -----**<br>
**Appendix**
**I**
**SAK – The Classic**
## “SAK – A real classic that became synonymous with connection technology”
## **Or**
## **“Once upon a time there was a company called Weidmüller that created the best terminals in the world using plastic and metal”.**
Weidmüller has an interesting story to tell about SAK terminals. SAK (German abbreviation for „side-by-side mountable terminals“) is the designation for a terminal that has proven itself on the market for more than 55 years. Using the side-by-side mounting principal, electrical terminals made of plastic replaced breakable porcelain constructions in switchgear cabinets.
One could as a result say: „SAK was the first family of terminals in the world that helped the electrical industry make a technological breakthrough”.
Further developments of the terminals and passive connection technology form the Weidmüller group‘s traditional core business.
## **SAK wire connections – synonymous with reliable connections and product variety.**
This long-term experience in the market enabled many improvements to be made. Nobody can claim that any other terminal on this earth has had as much know-how put into it as the SAK.
A great deal of know-how has been put into the inconspicuous insulating body with „clamping function” for electrical wires. This is because terminals have to withstand all kinds of unfavourable conditions. The connections system is chosen according to the respective application.
When looked at more closely, the demands made of an allegedly trivial component such as a terminal are considerable. Appropriately, the EN 60 947-7-1 defines terminals and cable connectors as equipment for connecting and joining electrical wires. Terminals can be mounted side-by-side or staggered, have two or several, independently functioning connection points, and are insulated both from one another and their mountings. They are mounted, for example, onto mounting rails.
As well as joining the wiring, terminals are also equipped with further functions:
when fitted with markers, terminals make it possible to clearly arrange „electrical installations”. Moreover, they create a defined connection point that can be extended as required. From this point, the wiring is routed to individual devices in the switchgear cabinet or from the switchgear cabinet to the devices. Terminal blocks increase serviceability, because electrical measurements can be carried out on them, targeted circuits can be opened or protected with appropriate protective elements.
Furthermore, cross-connections can be used to distribute potentials.
A clamping yoke system is used for securing the wiring in SAK terminals (see figure 1). The tension clamp system optimally combines the specific features of steel and copper. This system has proven itself millions of times over in electrical installations: in rough and aggressive industrial atmospheres, in power stations, ships and railway vehicles as well as in building automation.
The clamping yoke and the terminal screw used in Weidmüller’s clamping yoke system are made from case-hardened steel. The clamping yoke unit with a highstrength FZ terminal screw produces the required _ contact force and presses the con - ductor against the busbar, which is made either of copper or high-quality brass. The latter being tin coated.
**==> picture [25 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Figure 1<br>**----- End of picture text -----**<br>
**II**
**SAK – The Classic**
## High contact forces with the patented connection system
## **Plastics for terminals – thermoplastics**
## **and thermosetting plastics**
Thermal plastics are a polyamide (PA), and are one of the most frequently used technical plastics. The advantage of this material is its good electrical and mechanical characteristics, its flexibility and its lack of fracture susceptibility. In addition, this material offers good fire resistance due to its chemical structure without the need for added flameproofing substances. Engineers speak of a so-called „inherent flame protection”. The continuous operating temperature of the SAK range is 100 °C, and at the same time offering V2 fire resistance according to UL 94.
This ensures a „close fitting” and permanent contact with a low contact resistance. A gas-tight, vibration-resistant connection is created between the conductor and the busbar.
Because even a very good electrically conducting material is only as good as the contact force applied. Weidmüller’s patented connection system guarantees high contact forces. This means that it is predestined for use in corrosion-promoting environments; in addition, it is maintenance free. A further aspect is mounting and maintenance on an international scale, made possible by the world-renowned screw connection. One decisive factor for a perfect terminal is the insulating material.
Thermosetting plastics possess high dimensional stability, absorb a negligible amount of water, have a very high tracking resistance and excellent fire resistance. The continuous operating temperature is higher in comparison with that of thermoplastics. With increased thermal load, the dimensional stability of thermosetting plastics is better than that of thermoplastics. Their disadvantage: Thermosetting plastics have less flexibility in comparison with thermoplastics.
A further advantage of the SAK family is the large choice of different locking mechanisms. Its mounting rail designs (MR) offer the user the highest possible degree of convenience: TS 35 and TS 32 as well as a combi foot.
## **Technical background to the screw connection**
In order to meet the demands placed on terminals, it is necessary to use different insulating materials that are tailor-made for the application – thermoplastic or thermosetting plastic. All insulating materials used by Weidmüller are free from noxious substances and contain no paint pigments based on cadmium. The SAK family especially offers the option of specifically coordinating the terminals with material requirements in mind. In this case, Weidmüller offers the same construction with different insulation materials.
A spring element forms the basis for Weidmüller’s clamping yoke. Turning the terminal screw expands the upper flank of thread slightly, and in so doing locks itself in position. This construction efficiently compensates all expansions in the diameter of the wire (temperature fluctuations).
This has the following advantages:
of course the terminals age when in use; nevertheless, the terminal point does not yield. Consequently, it is not necessary to retighten the terminal screw at a later date nor does the wire become loose: it is resistant to vibration.
The voltage drop remains consistently low. Weidmüller’s technology is completely maintenance free.
Separating the electrical and mechanical functions means that we use steel for a high contact force, and the good electrical conducting properties of copper for a low voltage drop.
**III**
**SAK – The Classic**
**==> picture [250 x 214] intentionally omitted <==**
**----- Start of picture text -----**<br>
PS<br>STB<br>TSch<br>BS<br>BS<br>VL2<br>QL VH<br>VH Q BSK<br>AD4<br>DEK<br>AP<br>EW 35<br>TS 35 TW<br>**----- End of picture text -----**<br>
**Legend PS** Test plug **STB** Test socket screw **TSch** Small partition **BS** Fixing srew **QL** Cross-connection link **VH Q** Connection sleeve **EW 35** End brackets **TS 35** Mounting rail **VL** Connection link **BSK** Fixing srew **AD 4** Cover **DEK** Markers **AP** End plate **TW** Partition
## **A rundown on the SAK:**
The construction of the clamping yoke has been designed in such a manner to ensure that the connection between the wire and the busbar is gas-tight. The surface of the connection must make up at least 75 % of the surface as a whole. Electricity is conducted with 100 % efficiency at these points, because increased resistances due to soiling of the connection points do not arise. The SAK family is designed for wire cross-sections from 0.08 mm[2] to 240 mm[2] .
- PA 6.6, KrG
Two different materials that can be used, depending on the application, at 100 °C or 130 °C.
- Three different types of clip-on foot for mounting rail designs 32, 35 or a combination of both.
- Maintenance free and vibration-resistant There is no need to check the terminal point, because the patented clamping yoke construction ensures that the screws remain captive in the terminal.
Separating the tasks completed by the components offers the following advantages:
- Low voltage drop and gas-tight enclosed (electrical components). Perfect busbars in combination with a special surface treatment in conjunction with a high interference-fit at the terminal point.
- High contact forces, not reliant on the cross-section (mechanical components).
The clamping yoke is made of casehardened steel that, due to its design, can compensate any dimensional instability of the electrical wire.
**IV**
**SAK-Series**
## SAK-Series
## **The advantages of all SAK modular terminals:**
- Separation of electrical and mechanical functions: – steel clamping yoke for the mechanical function – copper busbar for the electrical function
- Maintenance-free and vibration-proof screw connection
- Low voltage drop and gas-tight contact point
- High contact forces, not reliant on the cross-section
- Three different clip-on foot designs available
- Various insulation materials
- Large selection of special terminals with diverse connection systems
- Large range of accessories available
Cross-sections from 0.5 mm[2] to 95 mm[2]
PA 6.6 material Cross-sections from 0.5 mm[2] to 35 mm[2]
Combination foot Special foot TS 32 and TS 35 rail in one for TS 35
Temperature ranges and materials 100 °C – PA 6.6 130 °C – KrG Special foot for TS 32
## **Product range**
|**Clamp type**<br>**Modular feed-through terminals**<br>PA 6.6 / TS 32|**Rated cross-section**<br>**2.5 mm2**<br>**4 mm2**<br>**•**<br>**•**|**Flat blade**<br>**connection**<br>**Push-on**<br>**connection**<br>**Spring**<br>**connection**<br>**Solder**<br>**connection**<br>**6 mm2**<br>**10 mm2**<br>**16 mm2**<br>**35 mm2**<br>•<br>•<br>•<br>•<br>•<br>•<br>•|
|---|---|---|
|KRG / TS 32|**•**<br>**•**|•<br>•<br>•<br>•<br>•<br>•<br>•<br>•|
|PA 6.6 / TS 35|**•**<br>**•**|•<br>•<br>•<br>•<br>•<br>•<br>•|
|KRG / TS 35|**•**<br>**•**|•<br>•<br>•<br>•<br>•|
|PA 6.6 / comb. foot|**•**<br>**•**|**•**<br>**•**<br>**•**<br>**•**|
|PA 6.6 / TS 15|**•**<br>**•**|**•**<br>**•**|
|Modular 2-tier terminals<br>**Modular PE terminals**<br>PA 6.6 / TS 32|**•**<br>**•**<br>**•**|**•**<br>**•**<br>**•**|
|PA 6.6 / TS 35|**•**<br>**•**|•<br>**•**<br>**•**<br>**•**|
|PA 6.6 / TS 15<br>**Modular fuse terminals**<br>PA 6.6 / TS 32|**•**<br>**•**|**•**|
|PA 6.6 / TS 35||**•**|
|KrG / TS 32||**•**<br>**•**|
|KrG / TS 35||**•**<br>**•**|
|PA 6.6 / TS 15|**•**||
|PA 6.6 / comb. foot<br>**Modular 2-tier fuse terminals**<br>PA 6.6 / TS 32|**•**<br>**•**||
|PA 6.6 / TS 35|**•**||
|PA 6.6 / comb. foot<br>**Modular disconnect terminals**|**•**||
|TS 35|**•**|**•**|
|PA 6.6 / TS 15|**•**||
|Modular 2-tier disconnect terminals|**•**|**•**|
|Modular ceramic terminals|**•**|•|
**V**
**VI**
**Contents**
**A**
## SAK-Series TS 35
## **SAK-Series TS 35**
|**Feed-through modular terminals**<br>TS 35 / PA|A.2|
|---|---|
|TS 35 / KrG|A.7|
|**Terminals with spring-loaded cable clamps**||
|TS 35 / PA|A.11|
|**Two-tier modular terminals**||
|TS 35 / PA|A.12|
|**Modular PE terminals**||
|TS 35 / PA|A.14|
|**Disconnect terminals**||
|TS 35 / PA|A.18|
|TS 35 / KrG|A.20|
|**Fuse terminals**||
|TS 35 / PA|A.22|
|TS 35 / KrG|A.24|
|Fuse inserts and gauge rings for Weidmüller fuse terminals|A.28|
|**Installation terminals**||
|TS 35 / PA|A.30|
|**Test-disconnect terminals**||
|TS 35 / KrG|A.32|
|**Terminals for temperature measuring circuits**||
|TS 35 / PA|A.34|
|**Terminals with screw-less connections**||
|With tab connection TS 35 / PA|A.36|
|With solder connection TS 35 / PA|A.40|
|**Special terminals – SAKG**||
|TS 35 / KrG|A.42|
|**Stud Terminal – KST**||
|TS 35 / PA|A.48|
|**Terminals with electronic components**||
|TS 35 / PA|A.50|
|**Earth conductor isolating terminals**|A.57|
**A.1**
**Feed-through modular terminals**
**SAKD 2.5/35**
**2.5 mm² SAK 2.5**
**2.5 mm²**
**A**
## **TS 35 / PA**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
**==> picture [507 x 249] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|5 x 44 x 38|6.1 x 44.5 x 40|
|max. current / max. cond. cross-section|A/mm²|30 / 4|41 / 6|
|Max. clamping range|mm²|0.33...4|0.13...6|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|Ex e II|T|II 2 G D|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|EN 60079-7|
|Rated voltage|V|500|300|300|800|600|600|550|
|Rated current|A|24|20|20|24|20|25|21|
|Rated cross-section|mm²|2.5|AWG 22...12|AWG 22...12|2.5|AWG 22...12|AWG 26...10|2.5|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A2 / V2|A3 / V2|
|Approvals|r|u|# a|?|r|u|# i ~ a|KEMA 97ATEX1798 U|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...4 / 0.5...4|0.5...6 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...2.5|0.5...4 / 0.5...4|
|Tightening torque range (clamping screw)|0.4...0.6 Nm (M 2.5)|0.4...0.6 Nm (M 2.5)|
|Stripping length / Blade size|mm/-|10 / 0.6 x 3.5 mm|10 / 0.6 x 3.5 mm|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|mm²|0.5...0.75|
|flexible / Stranded wire with end ferrules|mm²|0.5...0.75 / 0.5...0.75|
|Note|With twin ferrules ZH 0.5 to ZH 1.5, rated voltage is 690 V.|With twin ferrules ZH 0.5 to ZH 1.5, rated voltage is 690 V.|
|Ordering datag data data|
|Version|Typeypee|Qty.y..|Order No.|Typeypee|Qty.y..|Order No.|
|beigegee|SAKD 2.5/35|100|0268860000|SAK 2.5/35|100|0380460000|
|Blue|SAKD 2.5/35 BL|100|0268880000|SAK 2.5/35 BL|100|0380480000|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
**==> picture [331 x 321] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Typeypee|Qty.y..|Order No.|Typeypee|Qty.y..|Order No.|
|SAKD 2.5/35|100|0268860000|SAK 2.5/35|100|0380460000|
|SAKD 2.5/35 BL|100|0268880000|SAK 2.5/35 BL|100|0380480000|
|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|Q 2 SAKD2.5N|24 A|50|0367800000|Q 2 SAK2.5|41 A|50|0337000000|
|Q 3 SAKD2.5N|24 A|50|0367900000|Q 3 SAK2.5|41 A|50|0337100000|
|Q 4 SAKD2.5N|24 A|50|0368000000|Q 4 SAK2.5|41 A|50|0337200000|
|Q 10 SAKD2.5N|24 A|20|0368100000|Q 10 SAK2.5|41 A|20|0368700000|
|=|
|Width|Width|
|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/5/2.3/M3 SAK2.5|50|0280600000|
|AP SAKD2.5N|1.5 mm|20|0150960000|AP SAK2.5|1.5 mm|20|0279560000|
|AP SAKD2.5N BL|1.5 mm|20|0150980000|AP SAK2.5 BL|1.5 mm|20|0279580000|
|TW SAKD2.5N|1.5 mm|20|0191860000|TW SAK2.5|2.5 mm|20|0302860000|
|TW SAKD2.5N BL|1.5 mm|20|0191880000|TW SAK2.5 BL|1.5 mm|20|0302880000|
|TSCH 3 SAKD2.5 N|5 mm|100|0366860000|TSCH 1|2 mm|100|0319160000|
|AD 3 SAK2.5|50|0297900000|
|BFSC M3X22 PA/RT|100|0128900000|
|DEK 5/5 / SCHT 7|DEK 5/6 / SCHT 7|
**----- End of picture text -----**<br>
**Version Note**
**==> picture [159 x 328] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|beigegee|
|Blue|
|Note|
|Accessories|
|Screwable cross-connection|
|2-pole|
|3-pole|
|4-pole|
|10-pole|
|Connecting sleeve|
|Mounting screw|
|ttt|
|Lock washer|
|Switchable link|
|Switchable link|
|Connecting sleeve|
|Mounting screw|
|Testing / Checking|
|Test plug|
|Socket|
|End plate / Partition plate|
|beige|
|Blue|
|beige|
|Blue|
|Small partition|
|Small partition|
|Cover / warning label|
|Cover / warning label|
|Mounting screw (plastic)|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
## **Accessories**
**A.2**
**Feed-through modular terminals**
**SAK 4**
**4 mm² SAK 6**
**SAK 10**
**A**
## **6 mm²**
**10 mm²**
|6.5 x 45 x 44|6.5 x 45 x 44|||||||8 x 45 x 44||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**41 / 6**<br>**0.13...6**|||~~ob»~~|||||**57 / 10**<br>**0.33...10**||~~o_o~~||||
|IEC 60947-7-1||||Ex e IIT II 2 G D||||IEC 60947-7-1|||Ex e IIT II 2 G D|||
|**IEC**||**UL**||**CSA**||**EN 60079-7**||**IEC**||**UL**|**CSA**||**EN 60079-7**|
|800||600||600||550||800||600|600||550|
|32||30||36||28||41||40|47||36|
|4|AWG 22...12|||AWG 26...10||4||6|AWG 22...8||AWG 20...8||6|
||||8 / 3|||||||8 / 3||||
||||A4 / V2|||||||A5 / V2||||
|? r u #i ~ a||||KEMA 97ATEX1798 U|KEMA 97ATEX1798 U||? r u #i ~ a||||KEMA 97ATEX1798 U|KEMA 97ATEX1798 U||
|**Rated connection**||||||||**Rated connection**||||||
|0.5...6 / 0.5...4||||||||0.5...10 / 0.5...6||||||
|0.5...4 / 0.5...4||||||||0.5...10 / 0.5...6||||||
|0.5...1.0 Nm(M 3)||||||||0.8...1.6 Nm(M 3.5)||||||
|12 / 0.6 x 3.5 mm||||||||12 / 4.0 x 0.8 mm||||||
|||||||||||||||
|1.5...1.5||||||||||||||
|0.5...1.5||||||||||||||
|With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.|With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.|With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.|With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.|||||For AWG 8-7 and AWG 8-19, tightening torque is 1.21.4 Nm|For AWG 8-7 and AWG 8-19, tightening torque is 1.21.4 Nm|For AWG 8-7 and AWG 8-19, tightening torque is 1.21.4 Nm||||
|10 x 45 x 51.5|||||||
|---|---|---|---|---|---|---|
|**76 / 16**<br>**1.5...16**|~~ot»~~||||||
|IEC 60947-7-1|||Ex e IIT II 2 G D||||
|**IEC**<br>**UL**|||**CSA**|||**EN 60079-7**|
|800<br>600|||600|||550|
|57<br>60|||65|||50|
|10<br>AWG 14...6||AWG 16...6||||10|
|8 / 3|8 / 3||||||
|B6 / V2|||||||
|? r u #i ~ a|||KEMA 97ATEX1798 U|KEMA 97ATEX1798 U|KEMA 97ATEX1798 U||
|**Rated connection**|||||||
|1.5...10 / 1.5...16|||||||
|1.5...16 / 1.5...10|||||||
|2.0...4.0 Nm(M 4)|||||||
|12 / 1.0 x 5.5 mm|||||||
||||||||
||||||||
||||||||
|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.||When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|||
|**Type**|**Qty.**<br>**Order No.**||**Type**||**Qty.**|**Order No.**||**Type**|**Qty.**|**Order No.**|
|---|---|---|---|---|---|---|---|---|---|---|
|SAK 4/35|100<br>**0443660000**||SAK 6/35 PA||100|**0380560000**||SAK 10/35|100|**0443760000**|
|SAK 4/35 BL|100<br>**0443680000**||SAK 6/35 PA/BL||100|**0380580000**||SAK 10/35 BL|100|**0443780000**|
||||With AWG 6 and H07V-R10 conductors, an increased MD torque of 1.4|||||A higher torque of 2 to 2.4 Nm is necessary when using H07V-R16 and|A higher torque of 2 to 2.4 Nm is necessary when using H07V-R16 and||
||||to1.6 Nm should be used.|||||AWG 6 conductors.|||
||||||||||||
|**Type**|**current**<br>**Qty.**<br>**Order No.**||**Type**|**current**<br>**Qty.**||**Order No.**||**Type**|**current**<br>**Qty.**|**Order No.**|
|Q 2 SAK4|41 A<br>50<br>**0336700000**||Q 2 SAK6N|32 A|32 A<br>50|**0456700000**||Q 2 SAK10|57 A<br>50|**0457100000**|
|Q 3 SAK4|41 A<br>50<br>**0336800000**||Q 3 SAK6N|57 A|57 A<br>50|**0456800000**||Q 3 SAK10|57 A<br>50|**0457200000**|
|Q 4 SAK4|41 A<br>50<br>**0336900000**||Q 4 SAK6N|57 A|57 A<br>50|**0456900000**||Q 4 SAK10|57 A<br>50|**0457300000**|
|Q 10 SAK4|41 A<br>20<br>**0368800000**||Q 10 SAK6N|32 A|32 A<br>20|**0457000000**||Q 10 SAK10|57 A<br>20|**0457400000**|
||||||||||||
||||||||||||
||||||||||||
||||||||||||
|VL 2 SAK4|32 A<br>50<br>**0197000000**||VL 2 SAK6N/SAKT|32 A|32 A<br>50|**0194700000**||VL 2 SAK6/10/SAKB|32 A<br>50|**0135900000**|
|VH 19/5/3.5 SAK4-16|50<br>**0285100000**||VH 19/5/3.5 SAK4-16||50|**0285100000**||VH 19/5/3.5 SAK4-16|50|**0285100000**|
|BFSC M3X25|100<br>**0292500000**||BFSC M3X25||100|**0292500000**||BFSC M3X25|100|**0292500000**|
||**Width**|||**Width**|||||**Width**||
|PS 4 F.STB 4|7.6 mm<br>20<br>**0299600000**||PS 4 F.STB 4|7.6 mm<br>20||**0299600000**||PS 4 F.STB 4|7.6 mm<br>20|**0299600000**|
|STB 14/D5/2.3/M3 SAK2.5|50<br>**0168600000**||STB 14/D6/4/M3 SAK10||50|**0169900000**||STB 14/D6/4/M3 SAK10|50|**0169900000**|
||||||||||||
|AP SAK4-10|1.5 mm<br>20<br>**0117960000**||AP SAK4-10|1.5 mm<br>20||**0117960000**||AP SAK4-10|1.5 mm<br>20|**0117960000**|
|AP SAK4-10 BL|1.5 mm<br>20<br>**0117980000**||AP SAK4-10 BL|1.5 mm<br>20||**0117980000**||AP SAK4-10 BL|1.5 mm<br>20|**0117980000**|
|TW 4 SAK4-10|1.5 mm<br>20<br>**0130160000**||TW 4 SAK4-10|1.5 mm<br>20||**0130160000**||TW 4 SAK4-10|1.5 mm<br>20|**0130160000**|
|TW 4 SAK4-10 BL|1.5 mm<br>20<br>**0130180000**||TW 4 SAK4-10 BL|1.5 mm<br>20||**0130180000**||TW 4 SAK4-10 BL|1.5 mm<br>20|**0130180000**|
||||||||||||
|TSCH 1|2 mm<br>100<br>**0319160000**||TSCH 1|2 mm<br>100||**0319160000**||TSCH 1|2 mm<br>100|**0319160000**|
||||||||||||
|AD 4 SAK4|50<br>**0285300000**||AD 4 SAK6N||50|**0196600000**||AD 4 SAK10|50|**0178600000**|
|BFSC M3X22 PA/RT|100<br>**0128900000**||BFSC M3X22 PA/RT||100|**0128900000**||BFSC M3X22 PA/RT|100|**0128900000**|
|DEK 5/6,5 / SCHT 7|||DEK 5/8 / SCHT 7|||||DEK 5/5|||
||||When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.||||||
**A.3**
**Feed-through modular terminals**
**SAK 16**
**SAK 35/35**
**16 mm²**
**35 mm²**
**A**
## **TS 35 / PA**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
**==> picture [507 x 199] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|12 x 50 x 57.5|18 x 58 x 60|
|max. current / max. cond. cross-section|A/mm²|76 / 16|150 / 50|
|o——_4|0|o——__30|
|Max. clamping range|mm²|2.5...16|2.5...50|
|Technical data|IEC 60947-7-1|Ex e II|T|II 2 G D|IEC 60947-7-1|Ex e II|T|II 2 G D|
|Rated data|IEC|UL|CSA|EN 60079-7|IEC|UL|CSA|EN 60079-7|
|Rated voltage|V|1000|600|600|690|1000|600|600|550|
|Rated current|A|76|80|87|66|125|105|145|109|
|Rated cross-section|mm²|16|AWG 12...4|AWG 14...6|16|35|AWG 12...2|AWG 12...2|35|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|B6 / V2|B8 / V2|
|Approvals|?|r|u|# i ~ a|KEMA 97ATEX1798 U|r|u|# i ~ a|KEMA 97ATEX1798 U|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|2.5...16 / 4...16|2.5...16 / 4...50|
|flexible / Stranded wire with end ferrules|mm²|4...16 / 4...16|2.5...35 / 2.5...35|
|Tightening torque range (clamping screw)|2.0...4.0 Nm (M 4)|4.0...5.0 Nm (M 6)|
|Stripping length / Blade size|mm/-|15 / 1.0 x 5.5 mm|18 / 6.5 x 1.2 mm|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|mm²|2.5...10 / 10...16|
|flexible / Stranded wire with end ferrules|mm²|2.5...16 / 2.5...16|
|Note|Twin wire end ferrules ZH 2.5 - ZH 16 can be used.|The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-|
|ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering data**
**==> picture [508 x 338] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|beige|SAK 16/35 PA|50|0380660000|SAK 35/35|20|0380760000|
|Blue|SAK 16/35 PA/BL|50|0380680000|SAK 35/35 BL|20|0380780000|
|Note|If QIs are aligned side by side, then a TW/AP must be used.|It is possible to use twin ferrules with identical rated voltages (LAB 13090).|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|Q 2 SAK16|76 A|50|0457500000|QL 2 SAK35|110 A|20|0123600000|
|3-pole|Q 3 SAK16|76 A|50|0457600000|QL 3 SAK35|110 A|20|0123700000|
|4-pole|Q 4 SAK16|76 A|50|0457700000|QL 4 SAK35|110 A|20|0123800000|
|10-pole|Q 10 SAK16|76 A|20|0457800000|QL 10 SAK35|110 A|20|0338600000|
|Connecting sleeve|VH 17/8/5 SAK35|50|0267000000|
|Mounting screw|BFSC M4X30|50|0267100000|
|Lock washer|SS M4 D 128-A 4|100|0136400000|
|Switchable link|
|Switchable link|VL 2 SAK16/SAKA|57 A|50|0135800000|VL 2 SAK35|50|0124000000|
|Connecting sleeve|VH 19/5/3.5 SAK4-16|50|0285100000|VH 24.5/8/5 SAK35|50|0298700000|
|Mounting screw|BFSC M3X25|100|0292500000|BFSC M4X35|50|0298900000|
|Testing / Checking|Width|Width|
|Test plug|PS 4 F.STB 4|7.6 mm|20|0299600000|PS 4 F.STB 4|7.6 mm|20|0299600000|
|Socket|STB 14/D6/4/M3 SAK10|50|0169900000|STB 16/D7/4/M4 SAK35|50|0140200000|
|End plate / Partition plate|
|beige|AP SAK16|1.5 mm|20|0271160000|AP SAK35/TW SAK16|1.5 mm|10|0303660000|
|Blue|AP SAK16 BL|1.5 mm|20|0271180000|AP SAK35/TW SAK16 BL|1.5 mm|10|0303680000|
|beige|TW SAK35|1.5 mm|20|0304360000|
|Blue|
|Small partition|
|Small partition|TSCH 1|2 mm|100|0319160000|
|Cover / warning label|
|Cover / warning label|AD 4 SAK16|50|0518200000|AD 4 SAK35|50|0178700000|
|Mounting screw (plastic)|BFSC M3X22 PA/RT|100|0128900000|BFSC M4X32 PA/RT|100|0129100000|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/5|DEK 5/5 / SCHT 7|
|For detailed information on other accessories and ap-|If QIs are aligned side by side, then a TW/AP must be used.|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
## **Accessories**
**A.4**
**Feed-through modular terminals**
**SAK 35/35/IK 35 mm² SAK 35N/35**
**SAK 35N/35/IK**
**A**
## **Hexagon socket head screw**
## **35 mm²**
## **Hexagon socket head screw**
**35 mm²**
|18 x 58 x 60|18 x 58 x 60|||16 x 58 x 60|16 x 58 x 60|||||16 x 58 x 60|16 x 58 x 60||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**150 / 50**||||**150 / 50**||||||**150 / 50**|||||
|**2.5...50**||||**2.5...50**||||||**2.5...50**|||||
|IEC 60947-7-1||Ex e IIT II 2 G D||IEC 60947-7-1||||||IEC 60947-7-1|||||
|**IEC**|**UL**|**CSA**|**EN 60079-7**|**IEC**|**UL**|**CSA**||||**IEC**|**UL**|**CSA**|||
|1000|600|600|550|1000|600|600||||1000|600|600|||
|125|105|145|109|125|105|120||||125|105|120|||
|35|AWG 12...2|AWG 12...2|35|35|AWG 12...2|AWG 12...2||||35|AWG 12...2|AWG 12...2|||
||8 / 3||||8 / 3||||||8 / 3||||
||B8 / V2||||B8 / V2||||||B8 / V2||||
|r u #||KEMA 97ATEX1798 U|KEMA 97ATEX1798 U|r u #a||||||? r u #a|||||
|**Rated connection**||||**Rated connection**||||||**Rated connection**|||||
|2.5...16 / 4...50||||2.5...16 / 4...50||||||2.5...16 / 4...50|||||
|2.5...35 / 2.5...35||||2.5...35 / 1.5...35||||||2.5...35 / 1.5...35|||||
|4.0...6.0 Nm(M 6)||||4.0...5.0 Nm(M 6)||||||4.0...6.0 Nm(M 6)|||||
|18 / S4(DIN 6911)||||18 / 6.5 x 1.2 mm||||||18 / S4(DIN 6911)|||||
||||||||||||||||
|2.5...10 / 10...16||||2.5...10 / 10...16||||||2.5...10 / 10...16|||||
|2.5...16 / 2.5...16||||2.5...16 / 2.5...16||||||2.5...16 / 2.5...16|||||
|The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||||||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-|||||
|ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||||ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||||||ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.|||||
||||||||||||||||
|**Type**||**Qty.**|**Order No.**|**Type**||**Qty.**||**Order No.**||**Type**||**Qty.**||**Order No.**|
|SAK 35/35/IK||20|**0582460000**|SAK 35N/35||20||**0608260000**||SAK 35N/35/IK||20||**0608360000**|
||||||||||||||||
|It is possible to use twin ferrules with identical rated voltages (LAB 13090).||It is possible to use twin ferrules with identical rated voltages (LAB 13090).||It is possible to use twin ferrules with identical rated voltages (LAB 13090).||It is possible to use twin ferrules with identical rated voltages (LAB 13090).||||It is possible to use twin ferrules with identical rated voltages (LAB 13090).||It is possible to use twin ferrules with identical rated voltages (LAB 13090).|||
||||||||||||||||
|**Type**|**current**<br>**Qty.**||**Order No.**|**Type**|**current**<br>**Qty.**|||**Order No.**||**Type**|**current**<br>**Qty.**|||**Order No.**|
|QL 2 SAK35||99 A<br>20|**0123600000**|QL 2 SAK35N|110 A<br>50|||**0564900000**||QL 2 SAK35N||99 A<br>50||**0564900000**|
|QL 3 SAK35||99 A<br>20|**0123700000**|QL 3 SAK35N|110 A<br>50|||**0565000000**||QL 3 SAK35N||99 A<br>50||**0565000000**|
|QL 4 SAK35||99 A<br>20|**0123800000**|QL 4 SAK35N|110 A<br>50|||**0565100000**||QL 4 SAK35N||99 A<br>50||**0565100000**|
|QL 10 SAK35||99 A<br>20|**0338600000**|QL 10 SAK35N<br>110 A<br>20||||**0565200000**||QL 10 SAK35N||99 A<br>20||**0565200000**|
|VH 17/8/5 SAK35||50|**0267000000**|VH 17/8/5 SAK35||50||**0267000000**||VH 17/8/5 SAK35||50||**0267000000**|
|BFSC M4X30||50|**0267100000**|BFSC M4X30||50||**0267100000**||BFSC M4X30||50||**0267100000**|
|SS M4 D 128-A 4|SS M4 D 128-A 4|100|**0136400000**|SS M4 D 128-A 4|SS M4 D 128-A 4|100||**0136400000**||SS M4 D 128-A 4|SS M4 D 128-A 4|100||**0136400000**|
||||||||||||||||
|VL 2 SAK35|119 A<br>50||**0124000000**||||||||||||
|VH 24.5/8/5 SAK35||50|**0298700000**||||||||||||
|BFSC M4X35||50|**0298900000**||||||||||||
||**Width**||||**Width**||||||**Width**||||
|PS 4 F.STB 4|7.6 mm<br>20||**0299600000**|PS 4 F.STB 4|7.6 mm<br>20|||**0299600000**||PS 4 F.STB 4|7.6 mm<br>20|||**0299600000**|
|STB 16/D7/4/M4 SAK35||50|**0140200000**|STB 16/D7/4/M4 SAK35||50||**0140200000**||STB 16/D7/4/M4 SAK35||50||**0140200000**|
||||||||||||||||
|AP SAK35/TW SAK16|AP SAK35/TW SAK16<br>1.5 mm<br>10||**0303660000**|AP SAK35/TW SAK16|AP SAK35/TW SAK16<br>1.5 mm<br>10|||**0303660000**||AP SAK35/TW SAK16|AP SAK35/TW SAK16<br>1.5 mm<br>10|||**0303660000**|
|AP SAK35/TW SAK16 BL|AP SAK35/TW SAK16 BL<br>1.5 mm<br>10||**0303680000**|AP SAK35/TW SAK16 BL|AP SAK35/TW SAK16 BL<br>1.5 mm<br>10|||**0303680000**||AP SAK35/TW SAK16 BL|AP SAK35/TW SAK16 BL<br>1.5 mm<br>10|||**0303680000**|
|TW SAK35|1.5 mm<br>20||**0304360000**|TW SAK35|1.5 mm<br>20|||**0304360000**||TW SAK35|1.5 mm<br>20|||**0304360000**|
||||||||||||||||
||||||||||||||||
||||||||||||||||
||||||||||||||||
|AD 4 SAK35||50|**0178700000**|AD 4 SAK35N||50||**0576700000**||AD 4 SAK35N||50||**0576700000**|
|BFSC M4X32 PA/RT||100|**0129100000**|BFSC M4X32 PA/RT||100||**0129100000**||BFSC M4X32 PA/RT||100||**0129100000**|
|DEK 5/5||||DEK 5/5||||||DEK 5/5|||||
|If QIs are aligned side by side, then a TW/AP must be used.||||If QIs are aligned side by side, then a TW/AP must be used.||||||If QIs are aligned side by side, then a TW/AP must be used.|||||
**A.5**
**Feed-through modular terminals**
**SAK 70/35**
**70 mm²**
**A**
## **TS 35 / PA**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS35x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
## **Technical data**
**==> picture [159 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Rated data|
|Rated voltage|V|
|Rated current|A|
|Rated cross-section|mm²|
|Rated impulse voltage / Pollution severity|kV/-|
|Gauge to IEC 60947-1 / UL94 Flammability class|
|Approvals|
|Clamped conductors (H05V/H07V)|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Note|
**----- End of picture text -----**<br>
22 x 75 x 87 **192 / 70 16...70**
## IEC 60947-7-1
**==> picture [119 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|IEC|UL|CSA|
|1000|600|600|
|192|150|150|
|70|AWG 4...2/0|AWG 4...2/0|
|8 / 3|
|B11 / V2|
|r|u|# a|
|Rated connection|
|16...16 / 16...70|
|16...70 / 16...35|
|6.0...12 Nm (M 8)|
|24 / S6 (DIN 6911)|
**----- End of picture text -----**<br>
Tightening torque for 70 mm² stranded = 12 Nm.
## **Ordering data**
**==> picture [159 x 338] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Version|
|beige|
|Blue|
|Note|
|Accessories|
|Screwable cross-connection|
|2-pole|
|3-pole|
|4-pole|
|10-pole|
|Connecting sleeve|
|Mounting screw|
|Lock washer|
|Switchable link|
|Switchable link|
|Connecting sleeve|
|Mounting screw|
|Testing / Checking|
|Test plug|
|Socket|
|End plate / Partition plate|
|beige|
|Blue|
|beige|
|Blue|
|Small partition|
|Small partition|
|Cover / warning label|
|Cover / warning label|
|Mounting screw (plastic)|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
## **Accessories**
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|SAK 70/35|10|0139160000|
**----- End of picture text -----**<br>
**==> picture [155 x 256] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Type|current|Qty.|Order No.|
|QL 2 SAK70|192 A|20|0345300000|
|QL 3 SAK70|192 A|5|0167000000|
|VH 30.5/11/5.5 SAK70|20|0345500000|
|BFSC M5X45|20|0345600000|
|SS M5 D 128-A 5|50|0346100000|
|Width|
|PS 4 F.STB 4|7.6 mm|20|0299600000|
|STB 16/D7/4/M5 SAK70|50|0385400000|
|AP SAK70/35|2 mm|10|0340960000|
|AD 3 SAK70|10|0344300000|
|BFSC M5X45 PA/NA|50|0344400000|
|DEK 5/5|
**----- End of picture text -----**<br>
**A.6**
**Feed-through modular terminals**
**SAK 2.5**
**SAK 4**
**TS 35 / KrG**
**A**
## **2.5 mm²**
**4 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [507 x 169] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|6.1 x 49.5 x 40|6.5 x 45 x 44|
|max. current / max. cond. cross-section|A/mm²|32 / 6|41 / 6|
|o_o|ot»|
|Max. clamping range|mm²|0.13...6|0.13...6|
|Technical data|IEC 60947-7-1|Ex e II|T|II 2 G D|IEC 60947-7-1|Ex e II|T|II 2 G D|
|Rated data|IEC|UL|CSA|EN 60079-7|IEC|UL|CSA|EN 60079-7|
|Rated voltage|V|800|600|600|550|800|600|600|550|
|Rated current|A|24|20|25|21|32|30|36|28|
|Rated cross-section|mm²|2.5|AWG 22...12|AWG 26...10|2.5|4|AWG 22...12|AWG 26...10|4|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / 5VA|A4 / 5VA|
|Approvals|r|u|# i ~ a|KEMA 97ATEX1798 U|?|r|# i a|KEMA 97ATEX1798 U|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...6 / 0.5...4|0.5...6 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...2.5|0.5...4 / 0.5...4|
|Tightening torque range (clamping screw)|0.4...0.6 Nm (M 2.5)|0.5...1.0 Nm (M 3)|
|Stripping length / Blade size|mm/-|10 / 0.6 x 3.5 mm|12 / 0.6 x 3.5 mm|
|Note|With twin ferrules ZH 0.5 to ZH 1.5, rated voltage is 690 V.|With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering data**
**==> picture [155 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|SAK 2.5/35 KRG|100|0380420000|
|SAK 2.5/35 KRG/BL|100|0380470000|
**----- End of picture text -----**<br>
**==> picture [155 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|SAK 4/35 KRG|100|0443620000|
|SAK 4/35 KRG/BL|100|0443670000|
**----- End of picture text -----**<br>
**Version Note**
**==> picture [503 x 285] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Medium yellow|SAK 2.5/35 KRG|100|0380420000|SAK 4/35 KRG|100|0443620000|
|Blue|SAK 2.5/35 KRG/BL|100|0380470000|SAK 4/35 KRG/BL|100|0443670000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|Q 2 SAK2.5|41 A|50|0337000000|Q 2 SAK4|41 A|50|0336700000|
|3-pole|Q 3 SAK2.5|41 A|50|0337100000|Q 3 SAK4|41 A|50|0336800000|
|4-pole|Q 4 SAK2.5|41 A|50|0337200000|Q 4 SAK4|41 A|50|0336900000|
|10-pole|Q 10 SAK2.5|41 A|20|0368700000|Q 10 SAK4|41 A|20|0368800000|
|Connecting sleeve|
|Mounting screw|
|Lock washer|
|Switchable link|
|Switchable link|VL 2 SAK4|32 A|50|0197000000|
|Connecting sleeve|VH 19/5/3.5 SAK4-16|50|0285100000|
|Mounting screw|BFSC M3X25|100|0292500000|
|Testing / Checking|Width|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/5/2.3/M3 SAK2.5|50|0280600000|STB 14/D5/2.3/M3 SAK2.5|50|0168600000|
|End plate / Partition plate|
|Medium yellow|AP SAK2.5 KRG|1.5 mm|20|0279520000|AP SAK4-10 KRG|1.5 mm|20|0117920000|
|Blue|AP SAK2.5 KRG BL|1.5 mm|20|0279570000|AP SAK4-10 KRG/BL|1.5 mm|20|0117970000|
|Medium yellow|TW SAK2.5 KRG|2.5 mm|20|0302820000|TW SAK4-10 KRG|2.5 mm|20|0130120000|
|Blue|TW SAK2.5 KRG/BL|2.5 mm|20|0302870000|TW SAK4-10 KRG/BL|2.5 mm|20|0130170000|
|Small partition|
|Small partition|TSCH 1|2 mm|100|0319160000|TSCH 1|2 mm|100|0319160000|
|Cover / warning label|
|Cover / warning label|AD 4 AKZ4|50|0303400000|AD 4 SAK4|50|0285300000|
|Mounting screw (plastic)|BFSC M3X22 PA/RT|100|0128900000|BFSC M3X22 PA/RT|100|0128900000|
**----- End of picture text -----**<br>
## **Accessories**
**==> picture [159 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
DEK 5/6 / SCHT 7
DEK 5/6,5 / SCHT 7
**A.7**
**Feed-through modular terminals**
**A** 7
**SAK 6**
**SAK 10**
**6 mm²**
**10 mm²**
## **TS 35 / KrG**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
**==> picture [507 x 168] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|8 x 45 x 44|10 x 45 x 51.5|
|max. current / max. cond. cross-section|A/mm²|57 / 10|76 / 16|
|Max. clamping range|mm²|0.33...10|1.5...16|
|Technical data|IEC 60947-7-1|Ex e II|T|II 2 G D|IEC 60947-7-1|Ex e II|T|II 2 G D|
|Rated data|IEC|UL|CSA|EN 60079-7|IEC|UL|CSA|EN 60079-7|
|Rated voltage|V|800|600|600|550|800|600|600|550|
|Rated current|A|41|40|47|36|57|60|65|50|
|Rated cross-section|mm²|6|AWG 22...8|AWG 20...8|6|10|AWG 14...6|AWG 16...6|10|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A5 / 5VA|B6 / 5VA|
|Approvals|r|u|# i ~ a|KEMA 97ATEX1798 U|r|u|# i ~ a|KEMA 97ATEX1798 U|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...10 / 0.5...6|1.5...10 / 1.5...16|
|flexible / Stranded wire with end ferrules|mm²|0.5...10 / 0.5...6|1.5...16 / 1.5...10|
|Tightening torque range (clamping screw)|0.8...1.6 Nm (M 3.5)|2.0...4.0 Nm (M 4)|
|Stripping length / Blade size|mm/-|12 / 4.0 x 0.8 mm|12 / 1.0 x 5.5 mm|
|Note|For AWG 8-7 and AWG 8-19, tightening torque is 1.21.4 Nm|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering data**
**==> picture [157 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Typeypee|Qty.y..|Order No.|
|SAK 6/35 KRG|100|0380520000|
|SAK 6/35 KRG/BL|100|0380570000|
|With AWG 6 and H07V-R10 conductors, an increased MD torque of 1.4|
|to1.6 Nm should be used.|
**----- End of picture text -----**<br>
**==> picture [156 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Typeypee|Qty.y..|Order No.|
|SAK 10/35 KRG|100|0443720000|
|SAK 10/35 KRG/BL|100|0443770000|
|A higher torque of 2 to 2.4 Nm is necessary when using H07V-R16 and|
|AWG 6 conductors.|
**----- End of picture text -----**<br>
**==> picture [503 x 347] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Version|Typeypee|Qty.y..|Order No.|Typeypee|Qty.y..|Order No.|
|Medium yellow|SAK 6/35 KRG|100|0380520000|SAK 10/35 KRG|100|0443720000|
|Blue|SAK 6/35 KRG/BL|100|0380570000|SAK 10/35 KRG/BL|100|0443770000|
|Note|With AWG 6 and H07V-R10 conductors, an increased MD torque of 1.4|A higher torque of 2 to 2.4 Nm is necessary when using H07V-R16 and|
|to1.6 Nm should be used.|AWG 6 conductors.|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|Q 2 SAK6N|57 A|50|0456700000|Q 2 SAK10|57 A|50|0457100000|
|3-pole|Q 3 SAK6N|57 A|50|0456800000|Q 3 SAK10|57 A|50|0457200000|
|4-pole|Q 4 SAK6N|57 A|50|0456900000|Q 4 SAK10|57 A|50|0457300000|
|10-pole|Q 10 SAK6N|57 A|20|0457000000|Q 10 SAK10|57 A|20|0457400000|
|Connecting sleeve|
|Mounting screw|
|Lock washer|
|Switchable link|
|Switchable link|VL 2 SAK6N/SAKT|50|0194700000|VL 2 SAK6/10/SAKB|32 A|50|0135900000|
|Connecting sleeve|VH 19/5/3.5 SAK4-16|50|0285100000|VH 19/5/3.5 SAK4-16|50|0285100000|
|Mounting screw|BFSC M3X25|100|0292500000|BFSC M3X25|100|0292500000|
|Testing / Checking|Width|Width|
|Test plug|PS 4 F.STB 4|7.6 mm|20|0299600000|PS 4 F.STB 4|7.6 mm|20|0299600000|
|Socket|STB 14/D6/4/M3 SAK10|50|0169900000|STB 14/D6/4/M3 SAK10|50|0169900000|
|End plate / Partition plate|
|Medium yellow|AP SAK4-10 KRG|1.5 mm|20|0117920000|AP SAK4-10 KRG|1.5 mm|20|0117920000|
|Blue|AP SAK4-10 KRG/BL|1.5 mm|20|0117970000|AP SAK4-10 KRG/BL|1.5 mm|20|0117970000|
|Medium yellow|TW SAK4-10 KRG|2.5 mm|20|0130120000|TW SAK4-10 KRG|2.5 mm|20|0130120000|
|Blue|TW SAK4-10 KRG/BL|2.5 mm|20|0130170000|TW SAK4-10 KRG/BL|2.5 mm|20|0130170000|
|Small partition|
|Small partition|TSCH 1|2 mm|100|0319160000|TSCH 1|2 mm|100|0319160000|
|Cover / warning label|
|Cover / warning label|AD 4 SAK6N|50|0196600000|AD 4 SAK10|50|0178600000|
|Mounting screw (plastic)|BFSC M3X22 PA/RT|100|0128900000|BFSC M3X22 PA/RT|100|0128900000|
|Marking systems|(see assortment in catalogue 7)|
|DEK 5/8 / SCHT 7|DEK 5/5|
**----- End of picture text -----**<br>
## **Accessories**
**==> picture [159 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.
**A.8**
**Feed-through modular terminals**
**SAK 16**
**SAK 35N/35**
**SAK 35N/35/IK 35 mm²**
**A**
## **16 mm²**
## **35 mm²**
## **Hexagon socket head screw**
|12 x 50 x 57.5|12 x 50 x 57.5|||||16 x 58 x 60|16 x 58 x 60||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**76 / 16**||||||**125 / 50**|||||||
|**2.5...16**||||||**2.5...50**|||||||
|IEC 60947-7-1|||Ex e IIT II 2 G D|||IEC 60947-7-1|||||||
|**IEC**|**UL**||**CSA**|**EN 60079-7**||**IEC**||**UL**||**CSA**|||
|1000|600||600|690||1000||600||600|||
|76|80||87|66||125||105||120|||
|16|AWG 12...4||AWG 14...6|16||35|AWG 12...2||AWG 12...2||||
||8 / 3|||||||8 / 3|||||
||B6 / 5VA||B6 / 5VA|||||B8 / 5VA|B8 / 5VA||||
|r u #i a|||KEMA 97ATEX1798 U|KEMA 97ATEX1798 U|r u #a||||||||
|**Rated connection**||||||**Rated connection**|||||||
|2.5...16 / 4...16||||||2.5...16 / 4...50|||||||
|4...16 / 4...16||||||2.5...35 / 1.5...35|||||||
|2.0...4.0 Nm(M 4)||||||4.0...5.0 Nm(M 6)|||||||
|15 / 1.0 x 5.5 mm||||||18 / 6.5 x 1.2 mm|||||||
|Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-|||
|||||||ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||||ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.|||
|16 x 58 x 60|||||||
|---|---|---|---|---|---|---|
|**125 / 50**|||||||
|**2.5...50**|||||||
|IEC 60947-7-1|||||||
|**IEC**||**UL**||**CSA**|||
|1000||600||600|||
|125||105||120|||
|35|AWG 12...2||AWG 12...2||||
|||8 / 3|||||
|||B8 / 5VA|B8 / 5VA||||
|r u #a|||||||
|**Rated connection**|||||||
|2.5...16 / 4...50|||||||
|2.5...35 / 1.5...35|||||||
|4.0...6.0 Nm(M 6|M 6)||||||
|18 / S4(DIN 6911)|||||||
|The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-|||
|ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||||ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.|||
|**Type**|**Qty.**|**Order No.**|
|---|---|---|
|SAK 16/35 KRG|50|**0380620000**|
||||
|If QIs are aligned side by side, then a TW/AP must be used.|||
|**Type**|**Qty.**|**Order No.**|
|---|---|---|
|SAK 35N/35 KRG|20|**0608220000**|
||||
|It is possible to use twin ferrules with identical rated voltages (LAB 13090).||It is possible to use twin ferrules with identical rated voltages (LAB 13090).|
|**Type**|**Qty.**|**Order No.**|
|---|---|---|
|SAK 35N/35/IK KRG|20|**0608320000**|
|SAK 35N/35/IK KRG/BL|20|**0608370000**|
|It is possible to use twin ferrules with identical rated voltages (LAB 13090).||It is possible to use twin ferrules with identical rated voltages (LAB 13090).|
|**Type**|**current**<br>**Qty.**<br>**Order No.**||**Type**|**current**<br>**Qty.**|**Order No.**||**Type**|**current**<br>**Qty.**|**Order No.**|
|---|---|---|---|---|---|---|---|---|---|
|Q 2 SAK16|76 A<br>50<br>**0457500000**||QL 2 SAK35N|110 A<br>50|**0564900000**||QL 2 SAK35N|99 A<br>50|**0564900000**|
|Q 3 SAK16|76 A<br>50<br>**0457600000**||QL 3 SAK35N|110 A<br>50|**0565000000**||QL 3 SAK35N|99 A<br>50|**0565000000**|
|Q 4 SAK16|76 A<br>50<br>**0457700000**||QL 4 SAK35N|110 A<br>50|**0565100000**||QL 4 SAK35N|99 A<br>50|**0565100000**|
|Q 10 SAK16|76 A<br>20<br>**0457800000**||QL 10 SAK35N|110 A<br>20|**0565200000**||QL 10 SAK35N|99 A<br>20|**0565200000**|
||||VH 17/8/5 SAK35|50|**0267000000**||VH 17/8/5 SAK35|50|**0267000000**|
||||BFSC M4X30|50|**0267100000**||BFSC M4X30|50|**0267100000**|
||||SS M4 D 128-A 4|100|**0136400000**||SS M4 D 128-A 4|100|**0136400000**|
|||||||||||
|VL 2 SAK16/SAKA|57 A<br>50<br>**0135800000**|||||||||
|VH 19/5/3.5 SAK4-16|50<br>**0285100000**|||||||||
|BFSC M3X25|100<br>**0292500000**|||||||||
||**Width**|||**Width**||||**Width**||
|PS 4 F.STB 4|7.6 mm<br>20<br>**0299600000**||PS 4 F.STB 4|7.6 mm<br>20|**0299600000**||PS 4 F.STB 4|7.6 mm<br>20|**0299600000**|
|STB 14/D6/4/M3 SAK10|50<br>**0169900000**||STB 16/D7/4/M4 SAK35|50|**0140200000**||STB 16/D7/4/M4 SAK35|50|**0140200000**|
|||||||||||
|AP SAK16 KRG|3 mm<br>20<br>**0271120000**||AP SAK35 KRG|3 mm<br>10|**0303620000**||AP SAK35 KRG|3 mm<br>10|**0303620000**|
||||AP SAK35 KRG/BL|3 mm<br>10|**0303670000**||AP SAK35 KRG/BL|3 mm<br>10|**0303670000**|
|TW SAK16 KRG|3 mm<br>20<br>**0281120000**||TW SAK35 KRG|3 mm<br>20|**0304320000**||TW SAK35 KRG|3 mm<br>20|**0304320000**|
|||||||||||
|||||||||||
|TSCH 1|2 mm<br>100<br>**0319160000**|||||||||
|||||||||||
|AD 4 SAK16|50<br>**0518200000**||AD 4 SAK35|50|**0178700000**||AD 4 SAK35N|50|**0576700000**|
|BFSC M3X22 PA/RT|100<br>**0128900000**||BFSC M3X22 PA/RT|100|**0128900000**||BFSC M4X32 PA/RT|100|**0129100000**|
|DEK 5/5|||DEK 5/5||||DEK 5/5|||
||||If QIs are aligned side by side, then a TW/AP must be used.|If QIs are aligned side by side, then a TW/AP must be used.|||If QIs are aligned side by side, then a TW/AP must be used.|If QIs are aligned side by side, then a TW/AP must be used.||
**A.9**
**Feed-through modular terminals**
**SAK 95/35**
**95 mm²**
**A**
## **TS 35 / KrG**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
## **Technical data**
**==> picture [159 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Rated data|
|Rated voltage|V|
|Rated current|A|
|Rated cross-section|mm²|
|Rated impulse voltage / Pollution severity|kV/-|
|Gauge to IEC 60947-1 / UL94 Flammability class|
|Approvals|
|Clamped conductors (H05V/H07V)|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|Note|
**----- End of picture text -----**<br>
28 x 87.9 x 96.5 **269 / 120 16...120**
## IEC 60947-7-1
**==> picture [105 x 50] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|IEC|UL|CSA|
|1000|600|600|
|232|190|200|
|95|AWG 6...4/0|AWG 6...4/0|
|8 / 3|
|B12 / 5VA|
**----- End of picture text -----**<br>
**==> picture [163 x 69] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|r|# a|
|Rated connection|
|16...16 / 10...120|
|16...95 / 10...95|
|16...20 Nm (M 10)|
|30 / S8 (DIN 6911)|
|Ribbon cable (segmented ribbon) can be connected ranging from 3 to 6 segments|
|of 0.8x9 mm, up to 6 segments of 0.8x16 mm and up to 6 segments of 0.5x13 mm.|
**----- End of picture text -----**<br>
## **Ordering data**
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|SAK 95/35 KRG|10|0662220000|
**----- End of picture text -----**<br>
**Version Note**
**==> picture [335 x 355] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Medium yellow|SAK 95/35 KRG|10|0662220000|
|Blue|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAKG28|125 A|10|0551200000|
|3-pole|QL 3 SAKG28|232 A|5|0407600000|
|4-pole|QL 4 SAKG28|125 A|5|0407700000|
|10-pole|
|Connecting sleeve|—N—_|VH 35/11/5.5 SAK95|10|0551100000|
|Mounting screw|KISC M5X50/26 SAK95|20|0630200000|
|Lock washer|SS M5 D 128-A 5|50|0346100000|
|Switchable link|
|Switchable link|
|Connecting sleeve|
|Mounting screw|
|Testing / Checking|Width|
|Test plug|PS 4 F.STB 4|7.6 mm|20|0299600000|
|Socket|STB 16/D7/4/M5 SAK70|50|0385400000|
|End plate / Partition plate|
|Medium yellow|AP SAK95 KRG|3 mm|10|0550920000|
|Blue|AP SAK95 KRG/BL|3 mm|10|0550970000|
|Medium yellow|
|Blue|
|Small partition|
|Small partition|
|Cover / warning label|
|Cover / warning label|ADP 3/HP3 1M|20|0485400000|
|Mounting screw (plastic)|BFSC M5X45 PA/NA|50|0344400000|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/5 / SCHT 7|
|For detailed information on other accessories and ap-|Holder HP 3 0485760000 for the ADP 3-Profil.|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
## **Accessories**
**A.10**
**Terminals with spring-loaded cable clamps**
**RSF 3/35**
**A**
## **TS 35 / PA**
## **4 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
8 x 50 x 60 **32 / 4 0.33...4**
## **Technical data**
**==> picture [329 x 413] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|
|Rated voltage|V|690|600|600|
|Rated current|A|32|20|25|
|Rated cross-section|mm²|4|AWG 22...12|AWG 22...12|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|/ V2|
|Approvals|#|
|Clamped conductors (H05V/H07V)|Rated connection|
|solid / stranded|mm²|0.5...4 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...4|
|Tightening torque range (clamping screw)|0.5...1.0 Nm (M 3)|
|Stripping length / Blade size|mm/-|12 / 0.6 x 3.5 mm|
|Note|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|
|beige|RSF 3/35|50|9501160000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAK6N|57 A|50|0194300000|
|3-pole|QL 3 SAK6N|57 A|50|0194400000|
|4-pole|QL 4 SAK6N|57 A|50|0194500000|
|10-pole|QL 10 SAK6N|57 A|20|0338300000|
|Connecting sleeve|VH 13.5/4.9/3.3 SAK4|100|0248500000|
|Mounting screw|KISC M3X20.5/10 EK4|100|0303000000|
|Lock washer|SS M3 D 128-A 3|50|0164400000|
|Switchable link|
|Switchable link|VL 2 SAK6N/SAKT|50|0194700000|
|Connecting sleeve|VH 21/5/3.5 SAK16-35|50|0309600000|
|Mounting screw|BFSC M3X30|50|0296200000|
|Testing / Checking|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 14/D5/2.3/M3 SAK2.5|50|0168600000|
|End plate / Partition plate|
|beige|AP RSF3|3 mm|10|0270460000|
|beige|TW AST1/PA HP/DBR/0.5|0.5 mm|20|0474700000|
|Small partition|
|Small partition|TSCH 1|2 mm|100|0319160000|
|Cover / warning label|
|Cover / warning label|ADP 2/HP2 1M|36|0485300000|
**----- End of picture text -----**<br>
## **Ordering datag data data**
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
**A.11**
**Two-tier modular terminals**
**DK 4/35**
**DK 4 Q/35**
**4 mm²**
**A**
## **TS 35 / PA**
## **4 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
6 x 50 x 60.5
6 x 50 x 60.5 **41 / 6 0.13...6**
**41 / 6 0.13...6**
## **Technical data**
**==> picture [475 x 151] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|500|300|300|500|300|300|
|Rated current|A|32|27|10|32|27|10|
|Rated cross-section|mm²|4|AWG 22...12|AWG 26...12|4|AWG 22...12|AWG 26...12|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|6 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|A3 / V2|
|Approvals|r|u a|?|r|u ~ a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...6 / 0.5...4|0.5...6 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...2.5|0.5...4 / 0.5...2.5|
|Tightening torque range (clamping screw)|0.5...0.8 Nm (M 3)|0.5...0.8 Nm (M 3)|
|Stripping length / Blade size|mm/-|8 / 0.6 x 3.5 mm|8 / 0.6 x 3.5 mm|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|mm²|0.5...1.5|0.5...1.5|
|flexible / Stranded wire with end ferrules|mm²|0.5...1.5 / 0.5...1.5|0.5...1.5 / 0.5...1.5|
|Note|With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.|With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.|
**----- End of picture text -----**<br>
## **Ordering data**
**==> picture [503 x 220] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|beige|DK 4/35|100|0527660000|DK 4Q/35|100|0590160000|
|Blue|DK 4/35 BL|100|0527680000|DK 4Q/35 BL|100|0590180000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|Q 2 AKZ4|32 A|50|0336400000|Q 2 AKZ4|32 A|50|0336400000|
|3-pole|Q 3 AKZ4|32 A|50|0336500000|Q 3 AKZ4|32 A|50|0336500000|
|4-pole|Q 4 AKZ4|32 A|50|0336600000|Q 4 AKZ4|32 A|50|0336600000|
|10-pole|Q 10 AKZ4|32 A|20|0368600000|Q 10 AKZ4|32 A|20|0368600000|
|Testing / Checking|Width|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|End plate / Partition plate|
|beige|AP DK4|1.5 mm|20|0359260000|AP DK4Q|1.5 mm|20|1397160000|
|Blue|AP DK4 BL|1.5 mm|20|0359280000|AP DK4Q BL|1.5 mm|20|1397180000|
|Dark beige Wemid|WTW EN|3 mm|20|1058800000|WTW EN|3 mm|20|1058800000|
|Small partition|
|Small partition|TSCH 6 DKI S4|5 mm|100|0190260000|TSCH 6 DKI S4|5 mm|100|0190260000|
|Cover / warning label|
|Cover / warning label|AD 3 SAK2.5|50|0297900000|AD 3 SAK2.5|50|0297900000|
|Mounting screw (plastic)|BFSC M2.5X18 PA/RT|100|0303300000|BFSC M2.5X18 PA/RT|100|0303300000|
**----- End of picture text -----**<br>
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/6
DEK 5/6
**A.12**
**Two-tier modular terminals**
**DK 4 QV/35**
**A**
## **4 mm²**
6 x 54 x 40.5 **41 / 6 0.13...6**
**==> picture [117 x 59] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|IEC 60947-7-1|
|IEC|UL|CSA|
|500|300|300|
|32|27|10|
|4|AWG 22...12|AWG 26...12|
|6 / 3|
|A3 / V2|
**----- End of picture text -----**<br>
## ? r u ~ a
**Rated connection** 0.5...6 / 0.5...4 0.5...4 / 0.5...2.5 0.5...0.8 Nm (M 3) 8 / 0.6 x 3.5 mm 0.5...1.5 0.5...1.5 / 0.5...1.5 With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.
**==> picture [155 x 25] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|DK 4QV/35|100|0363660000|
|DK 4QV/35 BL|100|0363680000|
**----- End of picture text -----**<br>
**==> picture [155 x 154] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Type|current|Qty.|Order No.|
|Q 2 AKZ4|32 A|50|0336400000|
|Q 3 AKZ4|32 A|50|0336500000|
|Q 4 AKZ4|32 A|50|0336600000|
|Q 10 AKZ4|32 A|20|0368600000|
|Width|
|PS 2.3 RT|5.4 mm|20|0180400000|
|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|AP DK4Q|1.5 mm|20|1397160000|
|AP DK4Q BL|1.5 mm|20|1397180000|
|WTW EN|3 mm|20|1058800000|
|TSCH 6 DKI S4|5 mm|100|0190260000|
|AD 4 AKZ4|50|0303400000|
|BFSC M2.5X18 PA/RT|100|0303300000|
**----- End of picture text -----**<br>
DEK 5/6
**A.13**
**Modular PE terminals**
**EK 2.5/35**
**EK 4/35**
**4 mm²**
**A**
## **TS 35 / PA**
## **2.5 mm²**
|In hazardous area applications, the installation instructions|In hazardous area applications, the installation instructions||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|and the rated data specifications for accessories given in the|||||||||||||||
|technical appendix must be followed.|||||||||||||||
|**Technical data**<br>Width/Length/height with TS35x7.5<br>max. current / max. cond. cross-section<br>Max. clamping range|mm<br>A/mm²<br>mm²||6 x 56.5 x 40<br>**/ 6**<br>**0.33...6**<br>IEC 60947-7-2<br>~~re~~||||PE||6.5 x 56.5 x 44<br>**/ 6**<br>**0.33...6**<br>IEC 60947-7-2|6.5 x 56.5 x 44<br>PE<br>~~o—_ rT~~|||||
|**Rated data**|||**IEC**|**UL**|**CSA**||||**IEC**|**UL**|**CSA**||||
|Rated cross-section|mm²||2.5|AWG 22...12|AWG 26...10||||4|AWG 22...12|AWG 26...10||||
|Rated voltage to adjacent terminal|V||800||||||800||||||
|Rated impulse withstand voltage to adjacent terminal<br>kV|||8||||||8||||||
|Short-time withstand current||||480 A(4 mm²)||||||720 A(6 mm²)|||||
|Pollution severity||||3||||||3|||||
|Gauge to IEC 60947-1 / UL94 Flammabilityclass||||A3 / V2|A3 / V2|||||A4 / V2|A4 / V2||||
|Approvals|||r #i a||||||r #i a||||||
|**Clamped conductors(H05V/H07V)**|||**Rated connection**||||||**Rated connection**||||||
|solid / stranded|mm²||0.5...6 / 0.5...4||||||0.5...6 / 0.5...4||||||
|flexible / Stranded wire with end ferrules|mm²||0.5...4 / 0.5...2.5||||||0.5...4 / 0.5...4||||||
|Tighteningtorque range(clampingscrew)|||0.4...0.6 Nm(M 2.5|M 2.5)|||||0.5...1.0 Nm(M 3)||||||
|Tighteningtorque range(fixingscrew)|||0.4...0.6 Nm||||||0.5...1.0 Nm||||||
|Strippinglength / Blade size|mm/-||10 / 0.6 x 3.5 mm||||||12 / 0.6 x 3.5 mm||||||
|**Note**|||||||||||||||
|**Ordering data**|||||||||||||||
|**Version**|||**Type**||**Qty.**||**Order No.**||**Type**||**Qty.**|||**Order No.**|
|green/yellow|||EK 2.5/35||100||**0661060000**||EK 4/35||100|||**0661160000**|
|**Note**|||||||||||||||
|**Accessories**|||||||||||||||
|**Rail support**|||**Type**|**Width**<br>**Qty.**|||**Order No.**||**Type**|**Width**<br>**Qty.**||||**Order No.**|
||||SH 2|40 mm||10|**0494920000**||SH 2|40 mm||10||**0494920000**|
## **Technical data**
## **Ordering data**
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/6 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/6,5
**A.14**
**Modular PE terminals**
**A**
**==> picture [509 x 420] intentionally omitted <==**
**----- Start of picture text -----**<br>
EK 6/35 6 mm² EK 10 10 mm² EK 16 16 mm²<br>8 x 56.5 x 44 10 x 56 x 45 12 x 56 x 50<br> / 10 / 10 / 16<br>0.5...10 PE 0.5...10 PE 2.5...16 PE<br>IEC 60947-7-2 IEC 60947-7-2 IEC 60947-7-2<br>IEC UL CSA IEC UL CSA IEC UL CSA<br>6 AWG 22...8 AWG 20...8 10 AWG 14...6 AWG 14...6 16 AWG 10...6 AWG 10...4<br>800 800 800<br>8 8 8<br>720 A (6 mm²) 1200 A (10 mm²) 1920 A (16 mm²)<br>3 3 3<br>A5 / V2 B6 / V2 B6 / V2<br>r # a r # a r # a<br>Rated connection Rated connection Rated connection<br>0.5...10 / 1.5...6 0.5...10 / 1.5...6 2.5...16 / 2.5...16<br>0.5...10 / 0.5...6 0.5...10 / 0.5...10 2.5...16 / 4...16<br>0.8...1.6 Nm (M 3.5) 1.2...2.4 Nm (M 4) 2.0...4.0 Nm (M 4)<br>0.5...1.0 Nm 0.5...1.0 Nm 0.5...1.0 Nm<br>12 / 4.0 x 0.8 mm 12 / 1.0 x 5.5 mm 16 / 1.0 x 5.5 mm<br>For AWG 8-7 and AWG 8-19, tightening torque is 1.21.4 Nm<br>Type Qty. Order No. Type Qty. Order No. Type Qty. Order No.<br>EK 6/35 100 0661260000 EK 10/35 100 0661360000 EK 16/35 50 0190160000<br>Type Width Qty. Order No. Type Width Qty. Order No. Type Width Qty. Order No.<br>SH 2 40 mm 10 0494920000 SH 2 40 mm 10 0494920000 SH 2 40 mm 10 0494920000<br>**----- End of picture text -----**<br>
DEK 5/8
DEK 5/5 DEK 5/5
**A.15**
**Modular PE terminals**
**EK 35/35**
**EK 95/35**
**95 mm²**
**A**
## **TS 35 / PA**
## **35 mm²**
**==> picture [159 x 60] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|In hazardous area applications, the installation instructions|
|and the rated data specifications for accessories given in the|
|technical appendix must be followed.|
|Width/Length/height with TS35x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [508 x 287] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|16 x 58 x 60|25 x 76.5 x 90.5|
|max. current / max. cond. cross-section|A/mm²|/ 50|/ 120|
|Max. clamping range|mm²|6...50|—|PE|10...120|=|PE|
|Technical data|IEC 60947-7-2|IEC 60947-7-2|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated cross-section|mm²|35|AWG 6...2|AWG 12...2|95|
|Rated voltage to adjacent terminal|V|800|
|Rated impulse withstand voltage to adjacent terminal|kV|8|8|
|Short-time withstand current|4200 A (35 mm²)|11400 A (95 mm²)|
|Pollution severity|3|3|
|Gauge to IEC 60947-1 / UL94 Flammability class|B9 / V2|B12 / ---|
|Approvals|r|# a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|6...16 / 16...50|10...16 / 10...95|
|flexible / Stranded wire with end ferrules|mm²|10...35 / 10...35|16...95 / 10...95|
|Tightening torque range (clamping screw)|4.0...6.0 Nm (M 6)|10...20 Nm (M 10)|
|Tightening torque range (fixing screw)|1.2...2.4 Nm|1.2...2.4 Nm|
|Stripping length / Blade size|mm/-|20 / 6.5 x 1.2 mm|27 /|
|Note|Use the TS 35x15/2.3 for 35 - 50 mm² conductors. For AWG 2/7 and|Tightening torque for stranded conductors of 35 mm² and larger = 16 Nm|
|H07V-R50, torque is 6 Nm.|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|green/yellow|EK 35/35|20|0661460000|EK 95/35/1ZB BK|10|0535300000|
|Note|
|Accessories|
|Rail support|Type|Width|Qty.|Order No.|Type|Width|Qty.|Order No.|
|SH 2|40 mm|10|0494920000|SH 2|40 mm|10|0494920000|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
To fix the terminals use the copper rail TS35 order no. 0270100000.
**A.16**
**Modular PE terminals**
**SAKE 70/35**
**A**
## **70 mm²**
**==> picture [158 x 67] intentionally omitted <==**
**----- Start of picture text -----**<br>
18 x 94 x 59.5<br> / 70<br>10...70 o——_——° PE<br>IEC 60947-7-2<br>IEC UL CSA<br>70<br>**----- End of picture text -----**<br>
B10 / ---
## #
**Rated connection** 10...16 / 10...70 10...70 / 10...70 6.0...12 Nm (M 8) 2.0...4.0 Nm 25 /
When connecting with stranded conductors ≥ 50 mm² and 12 Nm tightening torque. Test current 8.4 kA to IK carried out via copper terminal rail
**==> picture [155 x 71] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type Qty. Order No.<br>EK 70/35/M.2ZB O.IK 10 1338300000<br>Type Width Qty. Order No.<br>SH 2 40 mm 10 0494920000<br>**----- End of picture text -----**<br>
Use the steel TS 35x15/2.3 for 35 - 50 mm² conductors. Use the TS 35x15/2.3 CU for 70 mm² conductors.
**A.17**
**Disconnect terminals**
**SAKR**
**SAKR-D**
**4 mm²**
**A**
## **TS 35 / PA**
## **4 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
**==> picture [465 x 168] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|6.5 x 42 x 40.5|6.5 x 46 x 38|
|max. current / max. cond. cross-section|A/mm²|10 / 4|OoO——1——|+#——_o|10 / 4|o——1—_|
|Max. clamping range|mm²|0.13...4|0.13...4|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|400|300|300|250|300|300|
|Rated current|A|10|10|10|10|10|10|
|Rated cross-section|mm²|4|AWG 22...12|AWG 22...12|4|AWG 26...12|AWG 22...12|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|6 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|A3 / V2|
|Approvals|#|r|#|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...4 / 1.5...4|0.5...4 / 1.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...2.5|0.5...4 / 0.5...2.5|
|Tightening torque range (clamping screw)|0.5...1.0 Nm (M 3)|0.5...1.0 Nm (M 3)|
|Stripping length / Blade size|mm/-|8 / 0.6 x 3.5 mm|8 / 0.6 x 3.5 mm|
|Note|Torque for SAKR with socket: 0.5 - 0.7 Nm.|Tightening torque via the sockets is 0.5 - 0.7 Nm.|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering data**
**==> picture [155 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|SAKR/35|100|0172160000|
|SAKR/35 BL|100|0172180000|
|SAKR/35 2 StB order no. 0183360000|
**----- End of picture text -----**<br>
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|SAKRD/35|50|0185760000|
**----- End of picture text -----**<br>
**Version Note**
**==> picture [503 x 145] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|beige|SAKR/35|100|0172160000|SAKRD/35|50|0185760000|
|Blue|SAKR/35 BL|100|0172180000|
|Note|SAKR/35 2 StB order no. 0183360000|
|Accessories|
|External cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QB 2 WI RA6 IS|27 A|50|0482700000|QB 2 WI RA6 IS|27 A|50|0482700000|
|3-pole|QB 3 WI RA6 IS|27 A|50|0482800000|QB 3 WI RA6 IS|27 A|50|0482800000|
|4-pole|QB 4 WI RA6 IS|27 A|50|0482900000|QB 4 WI RA6 IS|27 A|50|0482900000|
|Testing / Checking|Width|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 6/D3.7/2.3/M3 SAKR|100|0379400000|STB 6/D3.7/2.3/M3 SAKR|100|0379400000|
|End plate / Partition plate|
|beige|AP SAKR BE|1.5 mm|20|0211360000|AP SAKR BE|1.5 mm|20|0211360000|
|Blue|AP SAKR BL|1.5 mm|20|0211380000|AP SAKR BL|1.5 mm|20|0211380000|
**----- End of picture text -----**<br>
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/6,5 **For detailed information on other accessories and ap-** QB 25 blank, refer to „Accessories“ section. Note that max. conductor connection with QB = 2.5 mm². Twin wire-end ferrules ZH 0.5 - ZH 1.5
**For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/6,5
Twin wire-end ferrules ZH 0.5 - ZH 1.5 can be used.
**A.18**
**Disconnect terminals**
**A**
**==> picture [209 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
DKT 4 4 mm² DKT 4 V<br>**----- End of picture text -----**<br>
**==> picture [28 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
4 mm²<br>**----- End of picture text -----**<br>
## **Without separated busbar**
|6 x 65 x 56.5||||||6 x 65 x 56.5|||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**10 / 4**<br>**0.13...4**|**10 / 4**<br>**0.13...4**<br>Ooo||||||Ltt,|Ltt,|Ltt,|Ltt,|Ltt,|Ltt,|Ltt,|Ltt,|
|IEC 60947-7-1||||||IEC 60947-7-1|||||||||
|**IEC**|**UL**||**CSA**|||**IEC**|**UL**||**CSA**||||||
|400||||||400|||||||||
|10||||||10|||||||||
|4||||||4|||||||||
||6 / 3||||||6 / 3||||||||
||A3 / V2||||||A3 / V2||||||||
|r #a||||||#|||||||||
|**Rated connection**||||||**Rated connection**|||||||||
|0.2...4 / 1.5...4||||||0.5...4 / 1.5...4|||||||||
|0.2...4 / 0.5...2.5||||||0.5...4 / 0.5...2.5|||||||||
|0.5...1.0 Nm(M 3)||||||0.5...1.0 Nm(M 3)|||||||||
|9 / 0.6 x 3.5 mm||||||9 / 0.6 x 3.5 mm|||||||||
||||||||||||||||
||||||||||||||||
|**Type**|||**Qty.**||**Order No.**<br>**Type**||||**Qty.**|||**Order No.**|||
|DKT 4/35|||100||**0687460000**<br>DKT 4V/35 2STB||||100|||**1304960000**|||
||||||||||||||||
|DKT 4/35 2 StB Order No. 0327960000|||||||||||||||
|**Type**|**current**|**Qty.**|**Order No.**||**Type**|**current**|**Qty.**|**Order No.**|
|---|---|---|---|---|---|---|---|---|
|QB 2 WI RA6 IS|27 A|50|**0482700000**||QB 2 WI RA6 IS|27 A|50|**0482700000**|
|QB 3 WI RA6 IS|27 A|50|**0482800000**||QB 3 WI RA6 IS|27 A|50|**0482800000**|
|QB 4 WI RA6 IS|27 A|50|**0482900000**||QB 4 WI RA6 IS|27 A|50|**0482900000**|
||**Width**|||||**Width**|||
|PS 2.3 RT|5.4 mm|20|**0180400000**||PS 2.3 RT|5.4 mm|20|**0180400000**|
||||||||||
||||||||||
|AP DKT4 PA|1.5 mm|20|**0687560000**||AP DKT4 PA|1.5 mm|20|**0687560000**|
DEK 5/6
DEK 5/6
**A.19**
**Disconnect terminals**
**SAKC 4/35**
**SAKC 10/35**
**10 mm²**
**A**
## **TS 35 / KrG**
## **4 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
**==> picture [503 x 174] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|6.5 x 49.5 x 59.5|12 x 65 x 48.5|
|max. current / max. cond. cross-section|A/mm²|25 / 6|27 / 10|
|o—4—___+|0|ob4—__+4|
|Max. clamping range|mm²|0.33...6|0.5...10|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|400|300|300|500|300|600|
|Rated current|A|25|25|25|27|25|25|
|Rated cross-section|mm²|4|AWG 22...12|AWG 22...10|10|AWG 22...8|AWG 20...10|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|6 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A4 / 5VA|B6 / 5VA|
|Approvals|r|#|r|# a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...6 / 1.5...4|0.5...10 / 1.5...10|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...4|0.5...10 / 0.5...10|
|Tightening torque range (clamping screw)|0.5...1.0 Nm (M 3)|1.2...2.4 Nm (M 4)|
|Stripping length / Blade size|mm/-|12 / 0.6 x 3.5 mm|12 / 1.0 x 5.5 mm|
|Note|*UNDEFINED TEXT*|Connections for stranded conductors from 10 mm² require a tightening|
|torque of 2 Nm.|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering data**
**==> picture [503 x 237] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Medium yellow|SAKC 4/35|100|0357520000|SAKC 10/35 1STB4 KRG|50|1404520000|
|Note|SAKC 4/35 2 StB order no. 0340620000.|SAKC 10/35 2 StB4 Order No. 1404620000|
|Tightening torque via the sockets is 0.5 - 0.7 Nm.|Tightening torque via the sockets is 1.2 Nm.|
|Accessories|
|Screwable cross-connection|Type|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAKA10|47 A|50|0135500000|
|3-pole|QL 3 SAKA10|47 A|50|0135600000|
|4-pole|—§—_|QL 4 SAKA10|47 A|50|0135700000|
|Connecting sleeve|VH 13.6/7/4.2 SAKA10|50|0299700000|
|Mounting screw|a,|BFSC M4X20|100|0362800000|
|Lock washer|SS M4 D 128-A 4|100|0136400000|
|External cross-connection|current|
|2-pole|QB 2 WI RA6 IS|27 A|50|0482700000|
|3-pole|QB 3 WI RA6 IS|27 A|50|0482800000|
|4-pole|QB 4 WI RA6 IS|27 A|50|0482900000|
|Testing / Checking|Width|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 4 F.STB 4|7.6 mm|20|0299600000|
|Socket|STB 17/D6/4/M4 SAKC10|50|0147100000|
|End plate / Partition plate|
|Medium yellow|AP SAK4-10 KRG|1.5 mm|20|0117920000|AP SAKB/C/T KRG|3 mm|20|0146720000|
|Blue|AP SAK4-10 KRG/BL|1.5 mm|20|0117970000|
|beige|TW SAKB/C/T1|1.5 mm|20|0242960000|
|Medium yellow|TW SAK4-10 KRG|2.5 mm|20|0130120000|TW SAKB-C-T|3 mm|20|0242920000|
|Blue|TW SAK4-10 KRG/BL|2.5 mm|20|0130170000|
**----- End of picture text -----**<br>
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/6,5 Dummy plug and pull out tool see chapter accessories
DEK 5/6,5 Pull out force look under Accessories.
**A.20**
**A**
**A.21**
**Fuse terminals**
**KSKM 2**
**10 mm²**
**A**
## **TS 35 / PA**
## **KSKM 1**
## **5 x 20**
## **10 mm²**
**1“ x 1/4“**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
13 x 69 x 63
**6.3 / 16 0.13...16**
13 x 69 x 63 **13 / 16 0.13...16**
## **Technical data**
**==> picture [281 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Rated data|IEC|UL|CSA|
|Rated voltage|V|250|600|
|Rated current|A|6.3|10|
|Rated cross-section|mm²|10|AWG 26...8|
|Rated impulse voltage / Pollution severity|kV/-|
|Gauge to IEC 60947-1 / UL94 Flammability class|B6 / V-0|
|Approvals|# a|
|Clamped conductors (H05V/H07V)|Rated connection|
|solid / stranded|mm²|0.5...16|
|flexible / Stranded wire with end ferrules|mm²|0.5...10|
|Tightening torque range (clamping screw)|1.2...2.4 Nm (M 4)|
|Stripping length / Blade size|mm/-|12 / 1.0 x 5.5 mm|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|-|
|flexible / Stranded wire with end ferrules|-|
|Note|
**----- End of picture text -----**<br>
**==> picture [109 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|IEC|UL|CSA|
|250|600|
|13|15|
|10|AWG 26...8|
|B6 / V-0|
|# a|
|Rated connection|
|0.5...16|
|0.5...10|
|1.2...2.4 Nm (M 4)|
|12 / 1.0 x 5.5 mm|
**----- End of picture text -----**<br>
## **Ordering data**
**==> picture [329 x 238] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Type|Qty.|Order No.|Type|Qty.|Order No.|
|KSKM 1/35 G20|20|9509600000|KSKM 2/35 GZ 1X1/4|20|9509610000|
|Typeypee|Qty.|Order No.|Type|Width|Qty.|Order No.|
|G 20/0.10A/F|10|0430300000|
|G 20/0.20A/F|10|0430400000|
|G 20/0.25A/F|10|0430500000|
|G 20/0.50A/F|10|0430600000|
|G 20/0.63A/F|10|0439000000|
|G 20/1.00A/F|10|0430700000|
|G 20/1.60A/F|10|0430800000|
|G 20/2.00A/F|10|0430900000|
|G 20/2.50A/F|10|0431000000|
|G 20/3.15A/F|10|0431100000|
|G 20/4.00A/F|10|0431200000|
|G 20/5.00A/F|10|0431300000|
|G 20/6.30A/F|10|0431400000|
|SBL/1912|10|0446100000|SBL/2111|10|0446200000|
**----- End of picture text -----**<br>
**Version Note**
## **Accessories**
**==> picture [197 x 282] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|G-fuse cartridge, 5 x 20mm (IEC 60127-2)|Typeypee|
|0,10 A|
|0,20 A|
|0,25 A fast|
|0,50 A fast|
|0,63 A|
|1,00 A fast|
|1,60 A|
|2,00 A fast|
|2,50 A|
|3,15 A|
|4,00 A|
|5,00 A|
|6,30 A|
|G25 with indicator / imperial (inch) fuse|
|1,00 A|
|0,50 A medium slow / 2 A|
|1,00 A medium slow / 3 A|
|Contact sleeve|
|SBL/1912|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/5|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
DEK 5/5 Fuse 1“ x 1/4“ aren‘t available by Weidmüller.
**A.22**
**Fuse terminals**
**KDKS 1/35**
**A**
## **KSKM 3 10 mm²**
## **4 mm²**
## **1 1/4“ x 1/4“**
13 x 69 x 63.2 8 x 73.5 x 55.6 **10 / 160.33...16** OQ }+—_—o **6.3 / 40.33...4**
## IEC 60947-7-3
|**IEC**|**UL**|**CSA**|**IEC**|**UL**|**CSA**||
|---|---|---|---|---|---|---|
|440|600||500|300|||
|10|15||6.3|10|||
|10|AWG 22...8||4|AWG 22...12|||
|||||6 / 3|6 / 3||
||B6 / V-0|B6 / V-0||A3 / V2|A3 / V2||
|#a|||#a||||
|**Rated connection**|||**Rated connection**||||
|0.5...16|||0.5...4 / 1.5...4||||
|0.5...10|||0.5...4 / 0.5...4||||
|1.2...2.4 Nm(M 4)|||0.5...0.8 Nm(M 3)||||
|12 / 1.0 x 5.5 mm|||9 / 0.6 x 3.5 mm||||
||||||||
||||||||
||||||||
||||Note: max. conductor size = 2.5 mm² when using the cross-connection.||||
||||||||
|**Type**||**Qty.**|**Order No.**<br>**Type**||**Qty.**|**Order No.**|
|KSKM 3/35 GZ 1 1/4X1/4||20|**9509620000**<br>KDKS 1/35||50|**9503310000**|
||||Max. power loss (1.6 W) at the cartridge fuse limits the rated current.||||
||||||||
|**Type**||**Width**<br>**Qty.**|**Order No.**<br>**Type**||**Qty.**|**Order No.**|
||||G 20/0.10A/F||10|**0430300000**|
||||G 20/0.20A/F||10|**0430400000**|
||||G 20/0.25A/F||10|**0430500000**|
||||G 20/0.50A/F||10|**0430600000**|
||||||||
||||G 20/1.00A/F||10|**0430700000**|
||||G 20/1.60A/F||10|**0430800000**|
||||G 20/2.00A/F||10|**0430900000**|
||||G 20/2.50A/F||10|**0431000000**|
||||G 20/3.15A/F||10|**0431100000**|
||||G 20/4.00A/F||10|**0431200000**|
||||G 20/5.00A/F||10|**0431300000**|
||||||||
||||||||
|GZ 1.0A/F||10|**0525500000**||||
|GZ 2.0A||10|**0294500000**||||
|GZ 3.0A||10|**0295700000**||||
||||||**Width**||
|SBL/2489||10|**0446300000**||||
||||KOHUE ASK1||100|**0553300000**|
DEK 5/5
DEK 5/8
**A.23**
**Fuse terminals**
**SAKS 1/35 5x20**
**SAKS 1/35 5x20**
**10 mm²**
**A**
## **TS 35 / KrG**
## **10 mm²**
## **With LED or glow lamp**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
13 x 54 x 61 **10 / 16 0.13...16**
13 x 54 x 61 **6.3 / 16 0.5...16**
## **Technical data**
**==> picture [508 x 208] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|500|600|600|500|
|Rated current|A|10|6.3|10|6.3|
|Rated cross-section|mm²|10|AWG 22...10|AWG 26...10|10|AWG 22...8|AWG 26...10|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|4 /|
|Gauge to IEC 60947-1 / UL94 Flammability class|B6 / 5VA|B6 / 5VA|
|Approvals|?|r|u|# ~ a|#|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...16 / 1.5...10|0.5...16 / 1.5...10|
|flexible / Stranded wire with end ferrules|mm²|0.5...10 / 0.5...10|0.5...10 / 0.5...10|
|Tightening torque range (clamping screw)|1.2...2.4 Nm (M 4)|1.2...2.4 Nm (M 4)|
|Stripping length / Blade size|mm/-|12 / 1.0 x 5.5 mm|12 / 1.0 x 5.5 mm|
|Note|Connections for 10-mm² stranded conductors require a tightening torque|Connections for 10-mm² stranded conductors require a tightening torque|
|of 2 Nm.|of 2 Nm.|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|500 V AC/DC|SAKS 1/35/G20|20|0501620000|
|With GL 230 V AC/DC|SAKS 1/35 G20 GL 230VAC|10|0199920000|
|With GL 115 V AC/DC|SAKS 1/35 G20 GL 115VAC|10|8068330000|
|With LED 48 V AC|SAKS 1/35 G20 LD 48VAC|10|0214020000|
|With LED 24 V AC|SAKS 1/35 G20 LD 24VAC|10|1111320000|
|With LED +- 24 V DC|SAKS 1/35 G20 LD 24VDC|10|0225820000|
**----- End of picture text -----**<br>
## **Ordering datag data data**
**Version Note**
**==> picture [509 x 164] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|500 V AC/DC|SAKS 1/35/G20|20|0501620000|
|With GL 230 V AC/DC|SAKS 1/35 G20 GL 230VAC|10|0199920000|
|With GL 115 V AC/DC|SAKS 1/35 G20 GL 115VAC|10|8068330000|
|With LED 48 V AC|SAKS 1/35 G20 LD 48VAC|10|0214020000|
|With LED 24 V AC|SAKS 1/35 G20 LD 24VAC|10|1111320000|
|With LED +- 24 V DC|SAKS 1/35 G20 LD 24VDC|10|0225820000|
|500 V AC/DC|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|Qty.|Order No.|
|2-pole|QL 2 SAKS1|36 A|50|0191400000|
|3-pole|QL 3 SAKS1|36 A|50|0191500000|
|bi.|10-4-ppoleole|—§—VNVW—|QL 4 SAKS1QL 10 SAKS1|36 A36 A|2020|01916000000338800000|a ——_aa|
|End plate / Partition plate|Width|Width|
|Medium yellow|AP SAKS1+3 KRG|3 mm|20|0191320000|AP SAKS1+3 KRG|3 mm|20|0191320000|
**----- End of picture text -----**<br>
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags
**For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5 An M 3 x 6 mm screw, with order no. 0346200000, should be used for the cross-connection.
DEK 5/5
**A.24**
**Fuse terminals**
**A**
**==> picture [467 x 504] intentionally omitted <==**
**----- Start of picture text -----**<br>
SAKS 1/35 5x25 10 mm² SAKS 1/35 5x25 10 mm² SAKS 3/35<br>With glow lamp<br>13 x 54 x 61 13 x 54 x 61 13 x 54 x 61<br>10 / 16 6.3 / 16 10 / 16<br>0.13...16 0.5...16 0.33...16<br>IEC UL CSA IEC UL CSA IEC UL CSA<br>500 300 600 500 500 300 600<br>10 6.3 10 6.3 10 10 10<br>10 AWG 22...8 AWG 26...10 10 AWG 22...8 AWG 26...10 10 AWG 22...8 AWG 22...10<br>6 / 3 4 / 6 / 3<br>B6 / 5VA B6 / 5VA B6 / 5VA<br>? r u # ~ a # ? r u # ~ a<br>Rated connection Rated connection Rated connection<br>0.5...16 / 1.5...10 0.5...16 / 1.5...10 0.5...16 / 1.5...10<br>0.5...10 / 0.5...10 0.5...10 / 0.5...10 0.5...10 / 0.5...10<br>1.2...2.4 Nm (M 4) 1.2...2.4 Nm (M 4) 1.2...2.4 Nm (M 4)<br>12 / 1.0 x 5.5 mm 12 / 1.0 x 5.5 mm 12 / 1.0 x 5.5 mm<br>Connections for 10-mm² stranded conductors require a tightening torque Connections for 10-mm² stranded conductors require a tightening torque<br>of 2 Nm. of 2 Nm.<br>Type Qty. Order No. Type Qty. Order No. Type Qty.<br>SAKS 1/35/G25 20 0501520000 SAKS 3/35 G/5X30 500V 20<br>SAKS 1/35 G25 GL 230VAC 10 0198620000<br>SAKS 3/35 GZ/6.3X32 20<br>SAKS 3 1‘‘x1/4‘‘ with a red cap available under 0667420000.<br>Type current Qty. Order No. Type Qty. Order No. Type Qty.<br>QL 2 SAKS1 36 A 50 0191400000<br>QL 3 SAKS1 36 A 50 0191500000<br>QL 4 SAKS1 36 A 20 0191600000<br>QL 10 SAKS1 36 A 20 0338800000<br>Width Width Width<br>AP SAKS1+3 KRG 3 mm 20 0191320000 AP SAKS1+3 KRG 3 mm 20 0191320000 AP SAKS1+3 KRG 3 mm 20<br>**----- End of picture text -----**<br>
**==> picture [33 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
10 mm²<br>**----- End of picture text -----**<br>
|**Typeypee**||**Qty.y..**|**Order No.**|
|---|---|---|---|
|SAKS 3/35 G/5X30 500V||20|**0328920000**|
|||||
|||||
|||||
|||||
|||||
|SAKS 3/35 GZ/6.3X32||20|**0667520000**|
|SAKS 3 1‘‘x1/4‘‘ with a red cap available under 0667420000.||||
|||||
|**Typeypee**||**Qty.y..**|**Order No.**|
|||||
|||||
|||||
|||||
||**Width**|||
|AP SAKS1+3 KRG|3 mm|20|**0191320000**|
DEK 5/5 DEK 5/5 An M 3 x 6 mm screw, with order no. 0346200000, should be used for the cross-connection.
DEK 5/5
**A.25**
**Fuse terminals**
**SAKS 2/35**
**SAKS 4/35**
**10 mm²**
**A**
## **TS 35 / KrG**
## **10 mm²**
## **D 01-fuses**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
27.6 x 80 x 75 **10 / 16 0.33...16**
24 x 75 x 66 **16 / 16 0.33...16**
## **Technical data**
|**Technical data**|||||||||
|---|---|---|---|---|---|---|---|---|
|**Technical data**||IEC 60947-7-3||||IEC 60947-7-3|||
|**Rated data**||**IEC**<br>**UL**||**CSA**||**IEC**<br>**UL**||**CSA**|
|Rated voltage|V|500||600||400||600|
|Rated current|A|10||25||16||30|
|Rated cross-section|mm²|10|AWG 22...8|||10|AWG 22...8||
|Rated impulse voltage / Pollution severity|kV/-|6 / 3||||6 / 3|||
|Gauge to IEC 60947-1 / UL94 Flammabilityclass||B6 / 5VA|B6 / 5VA|||B6 / 5VA|B6 / 5VA||
|Approvals||? r u # m||||r u #~|||
|**Clamped conductors(H05V/H07V)**||**Rated connection**||||**Rated connection**|||
|solid / stranded|mm²|0.5...16 / 0.5...10||||0.5...16 / 1.5...10|||
|flexible / Stranded wire with end ferrules|mm²|0.5...10 / 0.5...10||||0.5...10 / 0.5...10|||
|Tighteningtorque range(clampingscrew)||1.2...2.4 Nm(M 4)||||1.2...2.4 Nm(M 4)|||
|Strippinglength / Blade size|mm/-|12 / 1.0 x 5.5 mm||||14 / 1.0 x 5.5 mm|||
|**Note**||Connections for stranded conductors from 10 mm² and 7-wire AWG con-||Connections for stranded conductors from 10 mm² and 7-wire AWG con-||Connections for stranded conductors from 10 mm² and 7-wire AWG con-||Connections for stranded conductors from 10 mm² and 7-wire AWG con-|
|||ductors require a tightening torque of 2 Nm.||||ductors require a tightening torque of 2 Nm.|||
## **Ordering data**
|**Version**||**Type**|**Qty.**|**Order No.**||**Type**|**Qty.**|**Order No.**|
|---|---|---|---|---|---|---|---|---|
|Without LED||SAKS 2/35|20|**1368720000**||SAKS 4/35|20|**0501820000**|
|**Note**|||||||||
|**Accessories**|||||||||
|**Screwable cross-connection**||**Type**|**current**<br>**Qty.**|**Order No.**||**Type**|**current**<br>**Qty.**|**Order No.**|
|2-pole||QL 2 SAKS2|47 A<br>20|**0207800000**||QL 2 SAKS4|36 A<br>20|**0328000000**|
|3-pole||QL 3 SAKS2|47 A<br>20|**0207900000**||QL 3 SAKS4|36 A<br>20|**0328100000**|
|4-pole||QL 4 SAKS2|47 A<br>20|**0208000000**||QL 4 SAKS4|36 A<br>20|**0328200000**|
|10-pole||QL 10 SAKS2|47 A<br>20|**0338900000**||QL 10 SAKS4|36 A<br>20|**0339000000**|
|Mountingscrew||BFSC M4X9T|100|**0103300000**||BFSC M4X9T|100|**0103300000**|
|Lock washer||SS M4 D 128-A 4|100|**0136400000**||SS M4 D 128-A 4|100|**0136400000**|
|**Screw cover cap**|||**Width**||||**Width**||
|SK||SK E16/SAKS2|25|**0284110000**||SK E14 SAKS4|20|**0339410000**|
|**Gauge rings**|||||||||
|||P 16/10 RT SAKS2|100|**0208900000**||P 14/2 D01 RS SAKS4|50|**0138000000**|
|||P 16/16 GR SAKS2|100|**0209000000**||P 14/4 D01 BR SAKS4|50|**0138100000**|
|||P 16/20 BL SAKS2|100|**0209100000**||P 14/10 D01 RT SAKS4|50|**0328700000**|
|||||||P 14/6 D01 GN SAKS4|50|**0328600000**|
|**Fuse cartridges**|||||||||
|||E 16/10A RT TNDZ|25|**0208500000**||E 14/2A RS|10|**0137400000**|
|||E 16/16A GR TNDZ|25|**0208600000**||E 14/4A BR|10|**0137500000**|
|||E 16/20A BL TNDZ|25|**0208700000**||E 14/6A GN|10|**0328300000**|
|||E 16/25A GE TNDZ|25|**0208800000**||E 14/10A RT|10|**0328400000**|
|||||||E 14/16A GR|10|**0328500000**|
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
**A.26**
**Fuse terminals**
**A**
## **SAKS 4/35 USA 10 mm² SAKS 5/35 1 1/4“ x 1/4“ D 02 - fuse**
**SAKS 5/35 16 mm²**
## **1 1/4“ x 1/4“**
24 x 75 x 73 28 x 80 x 66 **30 / 160.5...16** ol + **63 / 161.5...16**
## IEC 60947-7-3
|**IEC**|**UL**||**CSA**||**IEC**|**UL**||**CSA**||
|---|---|---|---|---|---|---|---|---|---|
|400|600||600||400|600||600||
|16|30||30||63|40||63||
|10|AWG 20...8||AWG 22...8||16|AWG 14...6||AWG 14...6||
||6 / 3|||||6 / 3||||
||B6 / 5VA|B6 / 5VA|B6 / 5VA|||B7 / 5VA|B7 / 5VA|B7 / 5VA||
|r #a|||||r u #~ a|||||
|**Rated connection**|||||**Rated connection**|||||
|0.5...16 / 1.5...10|||||1.5...16 / 1.5...16|||||
|0.5...10 / 0.5...10|||||1.5...16 / 1.5...16|||||
|1.2...2.4 Nm(M 4|M 4)||||1.2...2.4 Nm(M 4)|||||
|14 / 1.0 x 5.5 mm|||||13 / 1.0 x 5.5 mm|||||
|Connections for stranded conductors from 10 mm² and 7-wire AWG con-||||Connections for stranded conductors from 10 mm² and 7-wire AWG con-|Connections for stranded conductors from 10 mm² and 7-wire AWG con-||||Connections for stranded conductors from 10 mm² and 7-wire AWG con-|
|ductors require a tightening torque of 2 Nm.||ductors require a tightening torque of 2 Nm.|||ductors require a tightening torque of 2 Nm.||ductors require a tightening torque of 2 Nm.|||
|||||||||||
|**Type**|||**Qty.**|**Order No.**|**Type**|||**Qty.**|**Order No.**|
|SAKS 4/35 USA|||20|**0178220000**|SAKS 5/35|||20|**0502120000**|
|||||||||||
|||||||||||
|**Type**|**current**<br>**Qty.**|||**Order No.**|**Type**|**current**<br>**Qty.**|||**Order No.**|
|QL 2 SAKS4|||36 A<br>20|**0328000000**|QL 2 SAKS2|||47 A<br>20|**0207800000**|
|QL 3 SAKS4|||36 A<br>20|**0328100000**|QL 3 SAKS2|||47 A<br>20|**0207900000**|
|QL 4 SAKS4|||36 A<br>20|**0328200000**|QL 4 SAKS2|||47 A<br>20|**0208000000**|
|QL 10 SAKS4|||36 A<br>20|**0339000000**|QL 10 SAKS2|||47 A<br>20|**0338900000**|
|BFSC M4X9T|||100|**0103300000**|BFSC M4X9T|||100|**0103300000**|
|SS M4 D 128-A 4|||100|**0136400000**|SS M4 D 128-A 4|SS M4 D 128-A 4||100|**0136400000**|
|||**Width**|||||**Width**|||
|SK E14 SAKS4 USA|||1|**2012790000**|SK E18 SAKS5|||20|**0359310000**|
|||||||||||
||||||P 18/20 D02 BL SAKS5|||50|**0361800000**|
||||||P 18/25 D02 GE SAKS5|||50|**0361900000**|
||||||P 18/35 D02 SW SAKS5|||50|**0362000000**|
||||||P 18/50 D02 WS SAKS5|||50|**0362100000**|
|||||||||||
||||||E 18/20A BL|||10|**0361300000**|
||||||E 18/25A GE|||10|**0361400000**|
||||||E 18/50A WS|||10|**0361600000**|
||||||E 18/63A KU|||10|**0361700000**|
DEK 5/5
DEK 5/5
Partition wall TW HP (2.0) order no. 0607000000 only for TS 32
**A.27**
**Fuse inserts and gauge rings for Weidmüller fuse terminals**
**A**
## **Fuse inserts**
|**Technical data**<br>**for terminal type**<br>SAKS 1<br>SAKS 7<br>ASK 1||**Order data**<br>**G fuse inserts**5 x 20**without**indicator acc. to IEC 60127-2 (VDE 0820 T.2 Bl1)<br>**Qty.**<br>**Order No.**<br>**Size (mm)**<br>**Rated voltage (V)**<br>**Rated current (A)**<br>**Type**<br>0.1<br>(F)<br>G 20/0.10A/F<br>10<br>**0430300000**<br>5 x 20<br>0.2<br>(F)<br>G 20/0.20A/F<br>10<br>**0430400000**<br>Breaking capacity 1500 A<br>0.25<br>(F)<br>G 20/0.25A/F<br>10<br>**0430500000**|**Order data**<br>**G fuse inserts**5 x 20**without**indicator acc. to IEC 60127-2 (VDE 0820 T.2 Bl1)<br>**Qty.**<br>**Order No.**<br>**Size (mm)**<br>**Rated voltage (V)**<br>**Rated current (A)**<br>**Type**<br>0.1<br>(F)<br>G 20/0.10A/F<br>10<br>**0430300000**<br>5 x 20<br>0.2<br>(F)<br>G 20/0.20A/F<br>10<br>**0430400000**<br>Breaking capacity 1500 A<br>0.25<br>(F)<br>G 20/0.25A/F<br>10<br>**0430500000**|
|---|---|---|---|
|WSI 6||(at 250 V, 50 Hz, cos, cos:0.7)|0.5<br>(F)<br>G 20/0.50A/F<br>10<br>**0430600000**|
||||0.63<br>(F)<br>G 20/0.63A/F<br>10<br>**0439000000**|
|||250|1.0<br>(F)<br>G 20/1.00A/F<br>10<br>**0430700000**<br>1.6<br>(F)<br>G 20/1.60A/F<br>10<br>**0430800000**|
||||2.0<br>(F)<br>G 20/2.00A/F<br>10<br>**0430900000**|
||||2.5<br>(F)<br>G 20/2.50A/F<br>10<br>**0431000000**|
||||3.15<br>(F)<br>G 20/3.15A/F<br>10<br>**0431100000**|
||||4.0<br>(F)<br>G 20/4.00A/F<br>10<br>**0431200000**|
||||5.0<br>(F)<br>G 20/5.00A/F<br>10<br>**0431300000**|
||||6.3<br>(F)<br>G 20/6.30A/F<br>10<br>**0431400000**|
|||||
||||(M)= medium-delayed action(F)= fast|
|SAKS 1||**G fuse inserts**5 x 25**with**indicator acc. to DIN 415761)<br>5 x 25 m. K.1)<br>0.25<br>(M)<br>G 25/0.25A/M<br>10<br>**0546900000**||
|SAKS 7||Breaking capacity 80 A|0.5<br>(M)<br>G 25/0.50A/M<br>10<br>**0510300000**|
|WSI 6||(at 250 V, 50 Hz, cos:= 1)|0.8<br>(M)<br>G 25/0.80A/M<br>10<br>**0646400000**|
|||250|1<br>(M)<br>G 25/1.00A/M<br>10<br>**0265800000**|
||||10<br>(M)5)<br>G 25/10.0A/M<br>10<br>**0193100000**|
||||2<br>(F)<br>G 25/2.00A/F<br>10<br>**0192700000**|
||||4<br>(F)<br>G 25/4.00A/F<br>10<br>**0192800000**|
||||6.3<br>(F)<br>G 25/6.30A/F<br>10<br>**0192900000**|
|||||
||||M)= medium-delayed action(F)= fast|
|SAKS 32)||**Fuse inserts**1¼" x ¼"**without**indicator acc. to BS 88<br>33 kA Breaking capacity 33 kA fast<br>0.5<br>GZ 0.5A/F<br>10<br>**0533800000**||
|SAKS 6||E 0.5 A|1<br>GZ 1.0A/F<br>10<br>**0525500000**|
|||E 1<br>A<br>440|2<br>GZ 2.0A<br>10<br>**0294500000**|
|||E 2<br>A|3<br>GZ 3.0A<br>10<br>**0295700000**|
|||E 3<br>A|5<br>GZ 5.0A<br>10<br>**0294600000**|
|||E 5<br>A|7<br>GZ 7.0A<br>10<br>**0295800000**|
|||E 7<br>A|10<br>GZ 10.0A<br>10<br>**0293900000**|
|||E 10 A|12.5<br>GZ 12.5A/FF<br>10<br>**0245400000**|
|||||
||||(F)= fast(M)= miedium-delayed action|
|SAKS 2||**D fuse inserts**E 16**with**indicator acc. to DIN 49360 (diazed)<br>E 10 A<br>10<br>E 16/10A RT<br>25<br>**0208500000**||
|||E 16 A|16<br>E 16/16A GR<br>25<br>**0208600000**|
|i)||E 20 A<br>E 25 A<br>500|20<br>E 16/20A BL<br>25<br>**0208700000**<br>25<br>E 16/25A GE<br>25<br>**0208800000**<br>~~—8§—JuNVT—— aa~~|
||||F)= fast(M)= medium-delayed action|
|SAKS 44)||**D fuse inserts**E 14 Size D 01 and E 18 size D 02**with**indicator acc. to DIN 49522 (neozed)3)<br>E 14/2<br>2<br>E 14/2A RS<br>10<br>**0137400000**||
|||E 14/4|4<br>E 14/4A BR<br>10<br>**0137500000**|
|}||E 14/6<br>E 14/10<br>400<br>E 14/16|6<br>E 14/6A GN<br>10<br>**0328300000**<br>10<br>E 14/10A RT<br>10<br>**0328400000**<br>16<br>E 14/16A GR<br>10<br>**0328500000**<br>~~YN“_OO0,_7.—_~~|
|SAKS 5||E 18/20|20<br>E 18/20A BL<br>10<br>**0361300000**|
|||E 18/25|25<br>E 18/25A GE<br>10<br>**0361400000**|
|{2 8||E 18/35<br>E 18/50<br>400<br>E 18/63|35<br>E 18/35A SW<br>10<br>**0361500000**<br>50<br>E 18/50A WS<br>10<br>**0361600000**<br>63<br>E 18/63A KU<br>10<br>**0361700000**<br>~~________~~|
|||||
||||(F)= fast(M)= medium-delayed action|
- **Note:** 1) The SIBA company also supplies 5 x 25 G fuse inserts with indicators in a shipbuilding model for 450 V AC.
- 2) 5 x 30 (500 V AC) fuse inserts for SAKS 3 are available from the WICKMANN company
- 3) The LINDNER company also supplies neozed fuse cartridges in an additional shipbuilding mode for 440 V AC.
4) Fuse cartridges with the dimensions 1“x1/4“ c 25.4x6.35 mm and 13/32“x11/2“ c 10.3x38.1 mm are not included in product line. 5) Only for SAKS 1 and SAKS 7.
**A.28**
**Fuse inserts and gauge rings for Weidmüller fuse terminals**
**A**
## **Gauge rings**
|**Gauge rings**|||||||
|---|---|---|---|---|---|---|
|**Technical data**<br>**for terminal type**<br>SAKS 4 and 4/35||**Gauge ring type**<br>P 14/2<br>P 14/4<br>P 14/6||**Amp.**<br>**Colour**<br>**Type**<br>2<br>pink<br>P 14/2D01 RS<br>4<br>brown<br>P 14/4D01 BR<br>6<br>green<br>P 14/6D01 GN||**Order data**<br>**Qty.**<br>**Order No.**<br>50<br>**0138000000**<br>50<br>**0138100000**<br>50<br>**0328600000**|
|||P 14/1||10<br>red<br>P 14/10D01 RT||50<br>**0328700000**|
||||||||
||||||||
||||||||
||||||||
|SAKS 5 and 5/35||P 18/20||20<br>blue<br>P 18/20D02 BL||50<br>**0361800000**|
|||P 18/25||25<br>yellow<br>P 18/25D02 GE||50<br>**0361900000**|
|||P 18/35||35<br>black<br>P 18/35D02 SW||50<br>**0362000000**|
|||P 18/50||50<br>white<br>P 18/50D02 WS||50<br>**0362100000**|
||||||||
||||||||
||||||||
||||||||
|SAKS 2 and 2/35||P 16/10||10<br>red<br>P 16/10 RT||100<br>**0208900000**|
|||P 16/16||16<br>grey<br>P 16/16 GR||100<br>**0209000000**|
|||P 16/20||20<br>blue<br>P 16/20 BL||100<br>**0209100000**|
**A.29**
**Installation terminals**
**NT 2.5/35**
**2.5 mm² NT 6/35**
**6 mm²**
**A**
## **TS 35 / PA**
These NT modular terminals are prescribed for insulation measurements without detaching the conductors according to VDE standards for places of public assembly.
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
**==> picture [505 x 214] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|6 x 45 x 44|8 x 49 x 44|
|NT|NT|
|max. current / max. cond. cross-section|A/mm²|24 / 4|———€€££&@0|41 / 10|—K—o|
|Max. clamping range|mm²|0.33...4|0.5...10|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|400|300|300|400|300|300|
|Rated current|A|24|20|25|41|40|40|
|Rated cross-section|mm²|2.5|AWG 22...12|AWG 22...12|6|AWG 22...8|AWG 20...10|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|6 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|A5 / 5VA|
|Approvals|r # a|r # a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...4 / 0.5...4|0.5...10 / 0.5...10|
|flexible / Stranded wire with end ferrules|mm²|0.5...0.5 / 0.5...2.5|0.5...10 / 0.5...6|
|Tightening torque range (clamping screw)|0.5...0.8 Nm (M 2.5)|0.8...1.4 Nm (M 3.5)|
|Stripping length / Blade size|mm/-|10 / 0.6 x 3.5 mm|12 / 0.8 x 4 mm|
|Note|Tightening torque via disconnector is 0.5 ... 0.8 Nm.|Tightening torque via disconnector is 0.5 ... 0.8 Nm.|
|Ordering datag data data|
|Version|Typeypee|Qty.y..|Order No.|Typeypee|Qty.y..|Order No.|
|Blue|NT 2.5/35 10X3 BL|100|0471780000|NT 6/35 10X3 KRG/BL|100|0501470000|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
**==> picture [422 x 126] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Typeypee|Qty.y..|Order No.|Typeypee|Qty.y..|Order No.|
|Blue|NT 2.5/35 10X3 BL|100|0471780000|NT 6/35 10X3 KRG/BL|100|0501470000|
|quired every 20 cm)uired every 20 cm)y 20 cm) 20 cm))|Type|Width|Qty.|Order No.|Type|Width|Qty.|Order No.|
|Blue|HP NT2.5 BL|1.5 mm|20|0352080000|HP NT6/10 BL|1.5 mm|20|0352880000|
|p to OK, TS35 = 25,5 mm to OK, TS35 = 25,5 mm|SSCH 10X3X1000 CU/SN|10 mm|1|0348900000|SSCH 10X3X1000 CU/SN|10 mm|1|0348900000|
|pply to 10 x 3 busbarsly to 10 x 3 busbarsy to 10 x 3 busbars to 10 x 3 busbars|
|Rigid / flexible 0,5 - 6 / 4 mm²|ZB 4|5.6 mm|50|0316500000|ZB 4|5.6 mm|50|0316500000|
|rigid / flexible 6 - 16 mm²|ZB 16 ZKSC|10 mm|50|0316600000|ZB 16 ZKSC|10 mm|50|0316600000|
|Flexible 16 - 35 mm²|ZB 35/M6X16|14 mm|20|0266500000|ZB 35/M6X16|14 mm|20|0266500000|
**----- End of picture text -----**<br>
**Version Note**
## **Accessories**
**Support bracket for 10 x 3 (required every 20 cm)uired every 20 cm)y 20 cm) 20 cm))**
## **Busbar 10 x 3 (140 A)**
OK, Busbar up to OK, TS35 = 25,5 mm to OK, TS35 = 25,5 mm
## **Clamping yoke for power supply to 10 x 3 busbarsly to 10 x 3 busbarsy to 10 x 3 busbars to 10 x 3 busbars**
(see assortment in catalogue 7) Marking tags
**Marking systems**
**For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/6 Refer to the „Accessories“ section for PEN bridges and additional clamping-yoke versions. Use of twin wire-end ferrules on request.
DEK 5/6
Refer to the „Accessories“ section for PEN bridges and additional clamping-yoke versions. Use of twin wire-end ferrules on request.
**A.30**
**Installation terminals**
**NT 10/35**
**NT 16/35**
**10 mm²**
**A**
## **16 mm²**
|10 x 45 x 44|10 x 45 x 44|||||||12 x 59.5 x 58|12 x 59.5 x 58|12 x 59.5 x 58||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**57 / 16**||||NT<br>**76 / 16**<br>~~—-K—~~|||||||NT<br>~~———€€££&@0~~|||~~———€€££&@0~~|~~———€€££&@0~~|
|**0.5...16**||||||||**2.5...16**||||||||
|IEC 60947-7-1||||||||IEC 60947-7-1||||||||
|**IEC**||**UL**||**CSA**||||**IEC**||**UL**|**CSA**|||||
|400||300|||300|||400||300||300||||
|57||50|||50|||76||65||70||||
|10||AWG 14...8|AWG 14...8|||||16||AWG 16...6|AWG 12...6|||||
|||6 / 3||||||||6 / 3||||||
|||B6 / V2||||||||B6 / V2||||||
|r# a||||||||r# a||||||||
|**Rated connection**||||||||**Rated connection**||||||||
|0.5...16 / 0.5...10||||||||2.5...16 / 2.5...10||||||||
|0.5...10 / 0.5...10||||||||2.5...16 / 2.5...2.5||||||||
|1.2...1.6 Nm(M 4||M 4)||||||1.2...1.6 Nm(M 4||M 4)||||||
|12 / 1.0 x 5.5 mm||||||||12 / 1.0 x 5.5 mm||||||||
|Tightening torque via disconnector is 0.5 ... 0.8 Nm. Fix 10 mm² stranded|Tightening torque via disconnector is 0.5 ... 0.8 Nm. Fix 10 mm² stranded|||Tightening torque via disconnector is 0.5 ... 0.8 Nm. Fix 10 mm² stranded|Tightening torque via disconnector is 0.5 ... 0.8 Nm. Fix 10 mm² stranded|||Tightening torque via disconnector is 0.5 ... 0.8 Nm. Fix 10 mm² stranded<br>Isolator can accommodate 0.8..1.4 Nm. 10 and 16 mm² stranded and||||Isolator can accommodate 0.8..1.4 Nm. 10 and 16 mm² stranded and||||
|connection with 2 Nm tightening torque.|connection with 2 Nm tightening torque.|||||||AWG 8/7 connections are to be fixed with 2.4 Nm tightening torque.|||||||AWG 8/7 connections are to be fixed with 2.4 Nm tightening torque.|
|||||||||||||||||
|**Type**||||||**Qty.**||**Order No.**<br>**Type**|||||**Qty.**||**Order No.**|
|NT 10/35 10X3 BL||NT 10/35 10X3 BL|||||50|**0471880000**<br>NT 16/35 10X3 BL||NT 16/35 10X3 BL||||50|**0499280000**|
|||||||||||||||||
|||||||||||||||||
|**Type**|||**Width**||||**Qty.**|**Order No.**<br>**Type**|||**Width**|||**Qty.**<br>**Order No.**||
|HP NT6/10 BL|||1.5 mm||||20|**0352880000**<br>HP NT16/10X3|||2 mm|||20<br>**1266380000**||
|||||||||||||||||
|SSCH 10X3X1000 CU/SN|||10 mm||||1|**0348900000**<br>SSCH 10X3X1000 CU/SN|||10 mm||||1<br>**0348900000**|
|||||||||||||||||
|ZB 4|||5.6 mm||||50|**0316500000**<br>ZB 4|||5.6 mm|||50<br>**0316500000**||
|ZB 16 ZKSC|||10 mm||||50|**0316600000**<br>ZB 16 ZKSC|||10 mm|||50<br>**0316600000**||
|ZB 35/M6X16|||14 mm||||20|**0266500000**<br>ZB 35/M6X16|||14 mm|||20<br>**0266500000**||
DEK 5/6 Refer to the „Accessories“ section for PEN bridges and additional clamping-yoke versions. Use of twin wire-end ferrules on request.
DEK 5/5
Refer to the „Accessories“ section for PEN bridges and additional clamping-yoke versions. Use of twin wire-end ferrules on request.
**A.31**
**Test-disconnect terminals**
**SAKT 1/LT**
**SAKT 1/DU1**
**6 mm²**
**6 mm²**
**A**
## **TS 35 / KrG**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
|Width/Length/height with TS35x7.5|mm|8 x 65 x 52.5|8 x 65 x 52.5||||||||8 x 65 x 52.5|8 x 65 x 52.5|||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Technical data**<br>max. current / max. cond. cross-section<br>Max. clamping range|A/mm²<br>mm²|**57 / 10**<br>**0.13...10**<br>IEC 60947-7-1||~~o—t— ~~||||~~-$—»~~|||**57 / 10**<br>**0.13...10**<br>IEC 60947-7-1||~~o—t——__$5~~||||
|**Rated data**||**IEC**|**UL**||**CSA**||||||**IEC**|**UL**||**CSA**|||
|Rated voltage|V|400|300||300||||||400|300||300|||
|Rated current|A|41|25||25||||||41|25||25|||
|Rated cross-section|mm²|6|AWG 22...8||AWG 26...8||||||6|AWG 22...8||AWG 26...8|||
|Rated impulse voltage / Pollution severity|kV/-||6 / 3|||||||||6 / 3|6 / 3||||
|Gauge to IEC 60947-1 / UL94 Flammabilityclass|||A5 / 5VA|A5 / 5VA|A5 / 5VA|||||||A5 / 5VA|A5 / 5VA|A5 / 5VA|||
|Approvals|r# a||||||||||r# a||||||
|**Clamped conductors(H05V/H07V)**||**Rated connection**|||||||||**Rated connection**||||||
|solid / stranded|mm²|0.5...10 / 1.5...10|||||||||0.5...10 / 1.5...10||||||
|flexible / Stranded wire with end ferrules|mm²|0.5...6 / 0.5...6|||||||||0.5...6 / 0.5...6||||||
|Tighteningtorque range(clampingscrew)||0.8...1.6 Nm(M 3.5)|||||||||0.8...1.6 Nm(M 3.5)||||||
|Tighteningtorque range||0.5...0.8 Nm|||||||||||||||
|Strippinglength / Blade size|mm/-|12 / 4.0 x 0.8 mm|||||||||12 / 4.0 x 0.8 mm||||||
|**Note**||10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm|10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm||||||||10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm|10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm|||||
|||tightening torque.|||||||||tightening torque.||||||
## **Technical data**
## **Ordering data**
|**Type**||**Qty.**<br>**Order No.**|
|---|---|---|
|SAKT 1/35/LT|SAKT 1/35/LT|50<br>**0105420000**|
||||
|SAKT 1/35/LT STB|SAKT 1/35/LT STB|50<br>**0105620000**|
|**Type**||**Qty.**|**Order No.**|
|---|---|---|---|
|||||
|SAKT 1/35/DU1|SAKT 1/35/DU1|50|**0105820000**|
**Version**
|Without socket|SAKT 1/35/LT|50|**0105420000**|||||
|---|---|---|---|---|---|---|---|
|With open rear wall for cross-connection|||||SAKT 1/35/DU1|50|**0105820000**|
|With 2 sockets|SAKT 1/35/LT STB|50|**0105620000**|||||
|With 4 sockets||||||||
|**Note**||||||||
|**Accessories**||||||||
|**Screwable cross-connection**|**Type**|**current**<br>**Qty.**|**Order No.**||**Type**|**current**<br>**Qty.**|**Order No.**|
|2-pole|QL 2 SAK6N|57 A<br>50|**0194300000**||QL 2 SAK6N|32 A<br>50|**0194300000**|
|3-pole<br>4-pole<br>10-pole<br>Connectingsleeve<br>QL 3 SAK6N<br>57 A<br>50<br>**0194400000**<br>QL 4 SAK6N<br>57 A<br>50<br>**0194500000**<br>QL 10 SAK6N<br>57 A<br>20<br>**0338300000**<br>VH 12/4.9/3.3 SAK6N<br>100<br>**0249000000**<br>QL 3 SAK6N<br>57 A<br>50<br>**0194400000**<br>QL 4 SAK6N<br>57 A<br>50<br>**0194500000**<br>QL 10 SAK6N<br>32 A<br>20<br>**0338300000**<br>VH 12/4.9/3.3 SAK6N<br>100<br>**0249000000**<br>~~HH~~<br>~~OOO~~||||||||
|Mountingscrew|KISC M3X20 SAK10 CU5|100|**0377100000**||KISC M3X20 SAK10 CU5|100|**0377100000**|
|**Endplate / Partitionplate**||**Width**||||**Width**||
|Mediumyellow|AP SAKB/C/T KRG|3 mm<br>20|**0146720000**||AP SAKB/C/T KRG|3 mm<br>20|**0146720000**|
|beige|TW SAKB/C/T1|1.5 mm<br>20|**0242960000**||TW SAKB/C/T1|1.5 mm<br>20|**0242960000**|
|**Smallpartition**||||||||
|Smallpartition|TSCH 2|0.6 mm<br>100|**0353660000**||TSCH 2|0.6 mm<br>100|**0353660000**|
|**Cross-connection slider**||**current**||||**current**||
|2-pole|QVS 2 SAKT1+2|20|**0307300000**||QVS 2 SAKT1+2|41 A<br>20|**0307300000**|
|3-pole<br>4-pole<br>Connectingsleeve for QVS<br>Mountingscrew for QVS<br>QVS 3 SAKT1+2<br>20<br>**0329300000**<br>QVS 4 SAKT1+2<br>20<br>**0307400000**<br>VH 19/6/4.2 SAKT1<br>50<br>**0318000000**<br>BS 25 O.IH SAKT1<br>50<br>**0334700000**<br>QVS 3 SAKT1+2<br>41 A<br>20<br>**0329300000**<br>QVS 4 SAKT1+2<br>41 A<br>20<br>**0307400000**<br>VH 19/6/4.2 SAKT1<br>50<br>**0318000000**<br>BS 25 O.IH SAKT1<br>50<br>**0334700000**<br>~~att~~<br>~~OOO~~||||||||
|**Testing / Checking**||**Width**||||**Width**||
|Testplug|PS 4 F.STB 4|7.6 mm<br>20|**0299600000**||PS 4 F.STB 4|7.6 mm<br>20|**0299600000**|
|Socket|STB 14/D6/4/M3 SAK10|50|**0169900000**||STB 14/D6/4/M3 SAK10|50|**0169900000**|
|**Miscellaneous accessories**||||||||
|Lockout device|SSP 3 SAKT1|100|**0531760000**||SSP 3 SAKT1|100|**0531760000**|
|Short-circuitplug, 2-pole|QS 2/8/4|20|**0270960000**||QS 2/8/4|20|**0270960000**|
|**Marking systems**<br>(see assortment in catalogue 7)||||||||
|Marking tags|DEK 5/6,5||||DEK 5/6,5|||
|**For detailed information on other accessories and ap-**|To safe the test sockets use the SDIZ-blade (see chapter Tools) or bits||||To safe the test sockets use the SDIZ-blade (see chapter Tools) or bits|||
|**plications, refer to the „Accessories“ section**|with pilots!||||with pilots!|||
## **Accessories**
**A.32**
**Test-disconnect terminals**
**SAKT 1/QT**
**SAKT 2/LT**
**SAKT 4/35/LT**
**A**
## **6 mm²**
## **6 mm²**
**4 mm²**
|8 x 65 x 52.5<br>**57 / 10**|8 x 65 x 52.5<br>**57 / 10**|~~ok~~|~~ok~~|~~ok~~||8 x 82 x 52.5<br>**46 / 10**<br>~~n~~g|8 x 82 x 52.5<br>**46 / 10**<br>~~n~~g|~~a ~~|~~a ~~||~~oe~~||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**0.13...10**||||||**0.5...10**|||||||
|IEC 60947-7-1||||||IEC 60947-7-1|||||||
|**IEC**|**UL**||**CSA**|||**IEC**|**UL**||**CSA**||||
|400|300||300|||125|300||||||
|41|25||25|||41|25||||||
|6|AWG 22...8||AWG 26...8|||6|AWG 22...8||||||
||6 / 3|6 / 3|||||6 / 3|6 / 3|||||
||A5 / 5VA|A5 / 5VA|A5 / 5VA||||A5 / 5VA|A5 / 5VA|A5 / 5VA||||
|r# a||||||r# a|||||||
|**Rated connection**||||||**Rated connection**|||||||
|0.5...10 / 1.5...10||||||0.5...10 / 1.5...10|||||||
|0.5...6 / 0.5...6||||||0.5...6 / 0.5...6|||||||
|0.8...1.6 Nm(M 3.5)||||||1.2...1.6 Nm(M 3.5)|||||||
|0.5...0.8 Nm||||||0.5...0.8 Nm|||||||
|12 / 4.0 x 0.8 mm||||||12 / 4.0 x 0.8 mm|||||||
|10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm|10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm<br>10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm||||||10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm||||||
|tightening torque.||||||tightening torque.|||||||
|**Type**||**Qty.**|**Order No.**|
|---|---|---|---|
|SAKT 1/35/QT2|SAKT 1/35/QT2|50|**0124620000**|
|SAKT 1/35/QT1|SAKT 1/35/QT1|50|**0105720000**|
|**Type**||**Qty.**<br>**Order No.**|
|---|---|---|
||||
||||
|SAKT 2/35/LT/STB|SAKT 2/35/LT/STB|50<br>**0105920000**|
|SAKT 2/35/LT 4STB|SAKT 2/35/LT 4STB|50<br>**0106020000**|
|6 x 57.2 x 40<br>**41 / 6**|6 x 57.2 x 40<br>**41 / 6**|6 x 57.2 x 40<br>**41 / 6**|~~ob.~~|~~ob.~~|~~ob.~~|
|---|---|---|---|---|---|
||||~~ob.~~|~~ob.~~|~~ob.~~|
|**0.13...6**||||||
|IEC 60947-7-1|IEC 60947-7-1|||||
||**IEC**||**UL**|**CSA**||
||400||300|300||
||32||20|20||
||4|AWG 22...12||AWG 26...10||
||||6 / 3|||
||||A3 / 5VA|A3 / 5VA||
|#||||||
|**Rated connection**|||
|---|---|---|
|0.5...6 / 1.5...4|||
|0.5...4 / 0.5...4|||
|0.4...0.7 Nm(M 2.5)|||
|0.4...0.7 Nm|||
|10 / 0.6 x 3.5 mm|||
|Two conductors with the same cross-section can be accommodated. 1.5||Two conductors with the same cross-section can be accommodated. 1.5|
|mm² solid and 0.5...1.5 mm² flexible|||
||||
|**Type**|**Qty.**|**Order No.**|
|SAKT 4/35/LT O.STB|50|**1272420000**|
||||
|SAKT 4/35/LT STB2.0|50|**1272520000**|
|**Type**|**current**<br>**Qty.**<br>**Order No.**||**Type**|**current**<br>**Qty.**|**Order No.**||**Type**<br>**current**<br>**Qty.**<br>**Order No.**|
|---|---|---|---|---|---|---|---|
|QL 2 SAK6N|57 A<br>50<br>**0194300000**||QL 2 SAK6N|32 A<br>50|**0194300000**||QL 2 SAK2.5<br>41 A<br>100<br>**0155900000**|
|QL 3 SAK6N|57 A<br>50<br>**0194400000**||QL 3 SAK6N|57 A<br>50|**0194400000**||QL 3 SAK2.5<br>41 A<br>100<br>**0156000000**|
|QL 4 SAK6N|57 A<br>50<br>**0194500000**||QL 4 SAK6N|57 A<br>50|**0194500000**||QL 4 SAK2.5<br>41 A<br>50<br>**0156100000**|
|QL 10 SAK6N|57 A<br>20<br>**0338300000**||QL 10 SAK6N|32 A<br>20|**0338300000**||QL 10 SAK2.5<br>41 A<br>20<br>**0338100000**|
|VH 12/4.9/3.3 SAK6N|100<br>**0249000000**||VH 12/4.9/3.3 SAK6N|100|**0249000000**||VH 8/4.9/3.3 SAK2.5<br>100<br>**0266700000**|
|KISC M3X20 SAK10 CU5|100<br>**0377100000**||||||KISC M3X15/6 SAK2.5 CU5<br>100<br>**0377200000**|
||**Width**|||**Width**|||**Width**|
|AP SAKB/C/T KRG|3 mm<br>20<br>**0146720000**|||||||
|TW SAKB/C/T1|1.5 mm<br>20<br>**0242960000**||TW SAKT2|2.5 mm<br>20|**0351820000**||TW AST1/PA HP/DBR/0.5<br>0.5 mm<br>20<br>**0474700000**|
|||||||||
|TSCH 2|0.6 mm<br>100<br>**0353660000**||TSCH 2|0.6 mm<br>100|**0353660000**||TSCH 2<br>0.6 mm<br>100<br>**0353660000**|
||**current**|||**current**|||**current**|
|QVS 2 SAKT1+2|20<br>**0307300000**||QVS 2 SAKT1+2|41 A<br>20|**0307300000**||QVS 2/4 SAKT4<br>20<br>**1319260000**|
|QVS 3 SAKT1+2|20<br>**0329300000**||QVS 3 SAKT1+2|41 A<br>20|**0329300000**|||
|QVS 4 SAKT1+2|20<br>**0307400000**||QVS 4 SAKT1+2|41 A<br>20|**0307400000**|||
|VH 19/6/4.2 SAKT1|50<br>**0318000000**||VH 19/6/4.2 SAKT1|50|**0318000000**||VH 16/5/3.5 SAK10-35<br>50<br>**0309700000**|
|BS 25 O.IH SAKT1|50<br>**0334700000**||BS 25 O.IH SAKT1|50|**0334700000**||BFSC M3X22 SAKT4<br>50<br>**1319900000**|
||**Width**|||**Width**|||**Width**|
|PS 4 F.STB 4|7.6 mm<br>20<br>**0299600000**||PS 4 F.STB 4|7.6 mm<br>20|**0299600000**||PS 2.0 OR<br>5.4 mm<br>20<br>**0293800000**|
|STB 14/D6/4/M3 SAK10|50<br>**0169900000**||STB 14/D6/4/M3 SAK10|50|**0169900000**||STB 8.5/D4.5/2/M3 SAKT4<br>50<br>**0244600000**|
|||||||||
|SSP 3 SAKT1|100<br>**0531760000**||SSP 3 SAKT1|100|**0531760000**||SSP 4 SAKT4<br>20<br>**1319360000**|
|QS 2/8/4|20<br>**0270960000**||QS 2/8/4|20|**0270960000**|||
|DEK 5/6,5|DEK 5/6,5|
|---|---|
|To safe the test sockets use the SDIZ-blade (see chapter Tools) or bits|To safe the test sockets use the SDIZ-blade (see chapter Tools) or bits|
|with pilots!|with pilots!|
DEK 5/6,5 To safe the test sockets use the SD-blade or bits with pilots!
**A.33**
**Terminals for temperature measuring circuits**
**A** 7
## **TS 35 / PA**
## **DK 4 Q/TC**
## **4 mm²**
Busbars made from thermocouple materials according to DIN IEC 584
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
## **Technical data**
**==> picture [159 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Rated data|
|Rated voltage|V|
|Rated current|A|
|Rated cross-section|mm²|
|Rated impulse voltage / Pollution severity|kV/-|
|Gauge to IEC 60947-1 / UL94 Flammability class|
|Approvals|
|Clamped conductors (H05V/H07V)|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|Note|
**----- End of picture text -----**<br>
## **Ordering data**
**Version Note**
(NiCr - Ni) type K (Cu - CuNi) type T (Fe-CuNi) type J **Note Accessories End plate / Partition plate** beige beige Dark beige Wemid
## **Accessories**
6 x 54 x 59.5 **/ 4 ...4** IEC 60947-7-1 / IEC 60584 **IEC UL CSA** 4
A3 / V2 #
**Rated connection** 0.5...4 / 1.5...4 0.5...4 / 0.5...2.5 0.5...1.0 Nm (M 3) 9 / 0.6 x 3.5 mm
**==> picture [155 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Type|Qty.|Order No.|
|DK 4Q/35/TC TYP K|100|1284160000|
|DK 4Q/35/TC TYP T|100|1285660000|
|DK 4Q/35/TC TYP J|100|1284060000|
|Type|Width|Qty.|Order No.|
|AP DK4Q|1.5 mm|20|1397160000|
|TW SAKS2 HP/DBR/2|2 mm|20|0607000000|
|WTW EN|3 mm|20|1058800000|
**----- End of picture text -----**<br>
Weidmüller thermocouple terminals are specially designed for the transmission of very small voltages in temperature measuring circuits. Special current bars ensure that no false signals are transmitted within the terminal when temperature differences between the positive and negative paths exist. This high measuring precision is required, for example, in aircraft engine test rigs, complicated chemical processes, controllers, etc.
- Material of current bar corresponds to thermal and compensating conductors
- Clear thermocouple marking
- 2-pole blocks per thermocouple
- Modular width 10 mm
## **Configuration of a temperature measuring circuit**
**==> picture [160 x 72] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2 3 4 5 6<br>CH<br>AL<br>1 Thermocouple (sensor) 4 Reference junction<br>2 Thermocouple terminals 5 Supply and return conductors<br>3 Compensating conductor 6 Measuring instrument<br>**----- End of picture text -----**<br>
The thermocouple terminals shown in this measuring circuit are used for the thermoelectrical transmission of the thermoelectric voltage from the thermocouple to the reference junction and the indicator unit via the compensating conductor. Thermocouple terminals are required for constructing a temperature measuring circuit.
## **Technical data**
Thermocouples to IEC 584 (DIN 43 710)
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/6 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
**==> picture [158 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Busbar material|
|Terminal|trade name|
|a) Type J|
|Fe|Iron|
|(positive leg)|
|CuNi|Constantan|
|(negative leg)|
|b) Type T|
|Cu|Copper|
|(positive leg)|
|CuNi|Constantan|
|(negative leg)|
|c) Type K|
|NiCr|Chromel|
|(positive leg)|
|Ni|Alumel|
|(negative leg)|
**----- End of picture text -----**<br>
**A.34**
**A**
**A.35**
**Terminals with screw-less connections**
**AST 1 / 35**
**2.5 mm² AST 3/35**
**2.5 mm²**
**A**
## **With tab connection TS 35 / PA**
**==> picture [159 x 60] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|In hazardous area applications, the installation instructions|
|and the rated data specifications for accessories given in the|
|technical appendix must be followed.|
|Width/Length/height with TS35x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [506 x 474] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|6.5 x 58 x 46|6,3|6,3|6,3|6,3|6.5 x 40 x 40.1|6,3|6,3|
|max. current / max. cond. cross-section|A/mm²|20 / 2.5|2,8|2,8|2,8|2,8|20 / 2.5|2,8|2,8|
|Max. clamping range|mm²|0.5...2.5|...2.5|
|Technical data|IEC 60947-7-1 / IEC 61210|IEC 60947-7-1 / IEC 61210|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|500|600|300|500|300|300|
|Rated current|A|20|13|16|20|13|16|
|Rated cross-section|mm²|2.5|2.5|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|6 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|/ V2|/ V2|
|Approvals|r|u # a|r # a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|0.5...2.5|0.5...2.5|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|Note|The rated voltage is 800 V when using a cable-lug (flat) connector with IH|Cable-lug connections should be fitted with insulating sleeves. 20 A with|
|6.3 insulating sleeves.|F 6.3 or 2 x F 2.8|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Slotted|AST 1/35 6.3/2.8|50|0699660000|AST 3/35 6.3/2.8|100|0460360000|
|Not slit|AST 1/35 6.3|50|0664860000|AST 3/35 6.3|100|0479360000|
|Note|Cable-lug connections should be connected with insulating sleeves. 20 A|
|with F 6.3 or 2 x F 2.8|
|Accessories|
|Screwable cross-connection|Typeypee|current|Qty.y..|Order No.|Typeypee|current|Qty.y..|Order No.|
|2-polepoleole|Q 2 SAK4|41 A|50|0336700000|Q 2 SAK4|41 A|50|0336700000|
|3-polepoleole|Q 3 SAK4|41 A|50|0336800000|Q 3 SAK4|41 A|50|0336800000|
|4-polepoleole|Q 4 SAK4|41 A|50|0336900000|Q 4 SAK4|41 A|50|0336900000|
|10-polepoleole|Q 10 SAK4|41 A|20|0368800000|Q 10 SAK4|41 A|20|0368800000|
|Plug-in adapterg-in adapter-in adapterpterter|Width|
|2-polepoleole|STA 2.5/2|100|0165860000|
|3-polepoleole|STA 2.5/3|50|0165960000|
|4-polepoleole|STA 2.5/4|50|0190360000|
|5-polepoleole|STA 2.5/5|50|0166060000|
|8-polepoleole|STA 2.5/8|50|0166160000|
|End plate / Partition plateplate / Partition platelate / Partition plateplatelate|Width|
|beigegee|AP AST1+5 DB|1.5 mm|20|0266400000|
|Medium yellowyellowellow|AP AST3+4 KRG|3 mm|20|0298120000|
|beigegee|TW SAKS2 HP/DBR/2|2 mm|20|0607000000|TW 4 SAK4-10|1.5 mm|20|0130160000|
|Small partitionpartitionartition|
|Small partitionpartitionartition|TSCH 1|2 mm|100|0319160000|TSCH 1|2 mm|100|0319160000|
|Testing / Checkingg / Checking / Checkingg|
|Test plugpluglugg|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 14/D5/2.3/M3 SAK2.5|50|0168600000|STB 14/D5/2.3/M3 SAK2.5|50|0168600000|
|Insulating sleeveg sleeve sleeve|
|2,8|IH 2.8 DB|100|0386060000|IH 2.8 DB|100|0386060000|
|6,3|IH 6.3 WEM GE|100|0386260000|IH 6.3 WEM GE|100|0386260000|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
## **Accessories**
**==> picture [503 x 210] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Screwable cross-connection|Typeypee|current|Qty.y..|Order No.|Typeypee|current|Qty.y..|Order No.|
|2-polepoleole|Q 2 SAK4|41 A|50|0336700000|Q 2 SAK4|41 A|50|0336700000|
|3-polepoleole|Q 3 SAK4|41 A|50|0336800000|Q 3 SAK4|41 A|50|0336800000|
|4-polepoleole|Q 4 SAK4|41 A|50|0336900000|Q 4 SAK4|41 A|50|0336900000|
|10-polepoleole|Q 10 SAK4|41 A|20|0368800000|Q 10 SAK4|41 A|20|0368800000|
|Plug-in adapterg-in adapter-in adapterpterter|Width|
|2-polepoleole|STA 2.5/2|100|0165860000|
|3-polepoleole|STA 2.5/3|50|0165960000|
|4-polepoleole|STA 2.5/4|50|0190360000|
|5-polepoleole|STA 2.5/5|50|0166060000|
|8-polepoleole|STA 2.5/8|50|0166160000|
|End plate / Partition plateplate / Partition platelate / Partition plateplatelate|Width|
|beigegee|AP AST1+5 DB|1.5 mm|20|0266400000|
|Medium yellowyellowellow|AP AST3+4 KRG|3 mm|20|0298120000|
|beigegee|TW SAKS2 HP/DBR/2|2 mm|20|0607000000|TW 4 SAK4-10|1.5 mm|20|0130160000|
|Small partitionpartitionartition|
|Small partitionpartitionartition|TSCH 1|2 mm|100|0319160000|TSCH 1|2 mm|100|0319160000|
|Testing / Checkingg / Checking / Checkingg|
|Test plugpluglugg|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 14/D5/2.3/M3 SAK2.5|50|0168600000|STB 14/D5/2.3/M3 SAK2.5|50|0168600000|
|Insulating sleeveg sleeve sleeve|
|2,8|IH 2.8 DB|100|0386060000|IH 2.8 DB|100|0386060000|
|6,3|IH 6.3 WEM GE|100|0386260000|IH 6.3 WEM GE|100|0386260000|
**----- End of picture text -----**<br>
**==> picture [197 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/6|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
DEK 5/6 Pluggable adapter STA 2,5/2 - STA 2,5/8 only for PA - Version.
**A.36**
**Terminals with screw-less connections**
**AST 4/35**
**2.5 mm² AST 5/35**
**SAK 4 S/35**
**A**
**4 mm²**
**4 mm²**
**==> picture [510 x 474] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|6.2 x 40 x 40.1|6,3|6.5 x 58 x 46|6,3|6,3|6,3|6.5 x 40 x 49.5|6,3|
|20 / 4|2,8|20 / 6|2,8|2,8|2,8|20 / 6|2,8|
|6,3|
|0.2...4|0.2...6|0.13...6|2,8|
|IEC 60947-7-1 / IEC 61210|IEC 60947-7-1 / IEC 61210|IEC 60947-7-1 / IEC 61210|
|IEC|UL|CSA|IEC|UL|CSA|IEC|UL|CSA|
|500|300|300|500|300|300|500|600|300|
|20|13|16|20|13|16|20|13|13|
|2.5|AWG 22...12|AWG 24...12|4|AWG 22...12|AWG 24...12|4|AWG 26...12|AWG 26...12|
|6 / 3|6 / 3|6 / 3|
|A3 / V2|A4 / V2|A4 / V2|
|r|u # a|r|u # a|r|u # a|
|Rated connection|Rated connection|Rated connection|
|0.5...4 / 1.5...2.5|0.5...6 / 1.5...2.5|0.5...6 / 1.5...4|
|0.5...2.5 / 0.5...2.5|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|0.4...0.7 Nm (M 2.5)|0.5...1.0 Nm (M 3)|0.5...1.0 Nm (M 3)|
|9 / 0.6 x 3.5 mm|12 / 0.6 x 3.5 mm|12 / 0.6 x 3.5 mm|
|The rated voltage is 800 V when using a cable-lug (flat) connector with IH|The rated voltage is 800 V when using a cable-lug (flat) connector with IH|The rated voltage is 800 V when using a cable-lug (flat) connector with IH|
|6.3 insulating sleeves.|6.3 insulating sleeves.|6.3 insulating sleeves.|
|Type|Qty.|Order No.|Type|Qty.|Order No.|Type|Qty.|Order No.|
|AST 4/35 SF 6.3/2.8|100|0460460000|AST 5/35 SF 6.3/2.8|50|0664960000|SAK 4 S/35 6.3/2.8|100|0630360000|
|AST 4/35 SF 6.3|100|0479460000|
|Cable-lug connections should be connected with insulating sleeves. 20 A|Cable-lug connections should be connected with insulating sleeves. 20 A|Cable-lug connections should be connected with insulating sleeves. 20 A|
|with F 6.3 or 2 x F 2.8|with F 6.3 or 2 x F 2.8|with F 6.3 or 2 x F 2.8|
|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|Q 2 SAK4|41 A|50|0336700000|Q 2 SAK4|41 A|50|0336700000|QL 2 SAK4|32 A|100|0130600000|
|Q 3 SAK4|41 A|50|0336800000|Q 3 SAK4|41 A|50|0336800000|QL 3 SAK4|32 A|100|0130700000|
|Q 4 SAK4|41 A|50|0336900000|Q 4 SAK4|41 A|50|0336900000|QL 4 SAK4|32 A|50|0130800000|
|Q 10 SAK4|41 A|20|0368800000|Q 10 SAK4|41 A|20|0368800000|QL 10 SAK4|32 A|20|0338200000|
|Width|
|STA 2.5/2|100|0165860000|
|STA 2.5/3|50|0165960000|
|STA 2.5/4|50|0190360000|
|STA 2.5/5|50|0166060000|
|STA 2.5/8|50|0166160000|
|Width|Width|
|AP SAK2.5/35 + AST3+4|1.5 mm|20|0460560000|AP AST1+5 DB|1.5 mm|20|0266400000|AP SAK4-10|1.5 mm|20|0117960000|
|TW 4 SAK4-10|1.5 mm|20|0130160000|TW AST1/PA HP/DBR/0.5|0.5 mm|20|0474700000|TW 4 SAK4-10|1.5 mm|20|0130160000|
|TSCH 1|2 mm|100|0319160000|
|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|STB 14/D5/2.3/M3 SAK2.5|50|0168600000|STB 14/D5/2.3/M3 SAK2.5|50|0168600000|STB 14/D5/2.3/M3 SAK2.5|50|0168600000|
|IH 2.8 DB|100|0386060000|IH 2.8 DB|100|0386060000|IH 2.8 DB|100|0386060000|
|IH 6.3 WEM GE|100|0386260000|IH 6.3 WEM GE|100|0386260000|IH 6.3 WEM GE|100|0386260000|
**----- End of picture text -----**<br>
DEK 5/6 Pluggable adapter STA 2,5/2 - STA 2,5/8 only for PA - Version.
DEK 5/6,5
DEK 5/6,5
**A.37**
**Terminals with screw-less connections**
**SAK 4 SS/35**
**DK 4 SS/35**
**2.5 mm²**
**A**
## **With tab connection TS 35 / PA**
## **2.5 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5max. current / max. cond. cross-sectionMax. clamping range mm max. current / max. cond. cross-sectionMax. clamping range A/mm²mm²mm Max. clamping range mm²mm
**==> picture [506 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5max. current / max. cond. cross-sectionMax. clamping range|A/mm²mm²mm|6.5 x 40 x 49.5|20 / 2.50.5...2.5|6,32,86,32,8|TE|6,32,86,32,8|6 x 54 x 60.5|20 / 2.50.5...2.5|2,86,3|||en|2,86,3|or|2,86,3|2,86,3|
|Technical data|IEC 60947-7-1 / IEC 61210|IEC 60947-7-1 / IEC 61210|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|500|600|300|400|300|300|
|Rated current|A|20|13|13|20|10|10|
|Rated cross-section|mm²|2.5|AWG 26...12|AWG 26...12|2.5|AWG 22...12|AWG 22...12|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|4 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|/ V2|/ V2|
|Approvals|?|r|u # a|r|u # ~ a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|0.5...2.5|0.5...2.5|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|Note|The rated voltage is 800 V when using a cable-lug (flat) connector with IH|Cable-lug connections should be fitted with insulating sleeves. 20 A with|
|6.3 insulating sleeves.|F 6.3 and 2 x F 2.8|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering data**
**==> picture [160 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|SAK 4 SS/35 6.3/2.8|100|0630460000|
|Cable-lug connections should be connected with insulating sleeves. 20 A|
|with F 6.3 or 2 x F 2.8|
**----- End of picture text -----**<br>
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|DK 4SS/35 FF 4X6.3/2.8|100|0217160000|
**----- End of picture text -----**<br>
**Version Note**
Slotted Not slit 2-polepoleole 3-polepoleole 4-polepoleole 10-polepoleole 2-polepoleole 3-polepoleole 4-polepoleole 5-polepoleole 8-polepoleole beigegee Medium yellowyellowellow beigegee Small partitionpartitionartition Test plugpluglugg Socket 2,8 6,3
## **Accessories**
**==> picture [503 x 210] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-polepoleole|QL 2 SAK4|32 A|100|0130600000|Q 2 AKZ4|32 A|50|0336400000|
|3-polepoleole|QL 3 SAK4|32 A|100|0130700000|Q 3 AKZ4|32 A|50|0336500000|
|4-polepoleole|QL 4 SAK4|32 A|50|0130800000|Q 4 AKZ4|32 A|50|0336600000|
|10-polepoleole|QL 10 SAK4|32 A|20|0338200000|Q 10 AKZ4|32 A|20|0368600000|
|Plug-in adapter|
|2-polepoleole|
|3-polepoleole|
|4-polepoleole|
|5-polepoleole|
|8-polepoleole|
|End plate / Partition plate|Width|Width|
|beigegee|AP SAK4-10|1.5 mm|20|0117960000|AP DK4S|20|0631360000|
|Medium yellowyellowellow|
|beigegee|TW 4 SAK4-10|1.5 mm|20|0130160000|
|Small partition|
|Small partitionpartitionartition|TSCH 6 DKI S4|5 mm|100|0190260000|
|Testing / Checking|
|Test plugpluglugg|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|Insulating sleeve|
|2,8|IH 2.8 DB|100|0386060000|IH 2.8 DB|100|0386060000|
|6,3|IH 6.3 WEM GE|100|0386260000|IH 6.3 WEM GE|100|0386260000|
**----- End of picture text -----**<br>
**==> picture [202 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/6,5|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
DEK 5/6
**A.38**
**Terminals with screw-less connections**
**DK 4 S**
**A**
## **4 mm²**
**==> picture [158 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|6 x 54 x 59.5|6,3|
|2,8|
|20 / 4|6,32,8|
|0.33...4|
|IEC 60947-7-1 / IEC 61210|
|IEC|UL|CSA|
|400|300|300|
|10|10|10|
|4|AWG 22...12|AWG 22...12|
|6 / 3|
|A3 / V2|
|r|u # ~ a|
**----- End of picture text -----**<br>
## **Rated connection**
0.5...4 / 1.5...4 0.5...4 / 0.5...2.5 0.5...0.8 Nm (M 3) 8 / 0.6 x 3.5 mm Cable-lug connections should be fitted with insulating sleeves. 20 A supplied via F 6.3 or 2 x F 2.8.
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|DK 4S/35 SF 6.3/2.8|100|0686660000|
**----- End of picture text -----**<br>
**==> picture [155 x 210] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Type|current|Qty.|Order No.|
|Q 2 AKZ4|32 A|50|0336400000|
|Q 3 AKZ4|32 A|50|0336500000|
|Q 4 AKZ4|32 A|50|0336600000|
|Q 10 AKZ4|32 A|20|0368600000|
|Width|
|AP DK4S|20|0631360000|
|TSCH 6 DKI S4|5 mm|100|0190260000|
|PS 2.3 RT|5.4 mm|20|0180400000|
|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|IH 2.8 DB|100|0386060000|
|IH 6.3 WEM GE|100|0386260000|
**----- End of picture text -----**<br>
DEK 5/6
**A.39**
**Terminals with screw-less connections**
**A**
## **with solder connection TS 35 / PA**
## **SAK 2.5 LL**
## **1.5 mm²**
## **solder connection both sides**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
## **Technical data**
**==> picture [159 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Rated data|
|Rated voltage|V|
|Rated current|A|
|Rated cross-section|mm²|
|Rated impulse voltage / Pollution severity|kV/-|
|Gauge to IEC 60947-1 / UL94 Flammability class|
|Approvals|
|Clamped conductors (H05V/H07V)|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|Note|
**----- End of picture text -----**<br>
**==> picture [119 x 137] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|6 x 55 x 46.5|
|17.5 / 1.5|
|>__|
|0.13...1.5|
|IEC 60947-7-1 / IEC 60068-2-20|
|IEC|UL|CSA|
|250|300|
|17.5|10|
|1.5|AWG 26...12|
|4 / 3|
|/ V2|
|#|
|Rated connection|
|0.5...1.5|
|0.5...1.5|
**----- End of picture text -----**<br>
Solder connection both sides with max. 1.5 mm² conductor
## **Ordering data**
**Version Note**
beige **Note Accessories Screwable cross-connection** 10-pole 2-pole 3-pole 4-pole **Testing / Checking** Socket Test plug **End plate / Partition plate** beige Blue beige Tropical applications **Small partition** Small partition **Cover / warning label** Cover / warning label Mounting screw (plastic)
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags **For detailed information on other accessories and applications, refer to the „Accessories“ section**
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|SAK 2.5/35 LL|100|0567260000|
**----- End of picture text -----**<br>
**==> picture [155 x 164] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Type|current|Qty.|Order No.|
|Q 10 SAK2.5|41 A|20|0368700000|
|Q 2 SAK2.5|41 A|50|0337000000|
|Q 3 SAK2.5|41 A|50|0337100000|
|Q 4 SAK2.5|41 A|50|0337200000|
|Width|
|STB 8.5/5/2.3/M3 SAK2.5|50|0280600000|
|PS 2.3 RT|5.4 mm|20|0180400000|
|AP SAK2.5|1.5 mm|20|0279560000|
|AP SAK2.5 BL|1.5 mm|20|0279580000|
|TW SAK2.5|2.5 mm|20|0302860000|
|TW SAK2.5 HP/TF/GE/1|1 mm|20|0297100000|
|TSCH 1|2 mm|100|0319160000|
|AD 4 AKZ4|50|0303400000|
|BFSC M3X22 PA/RT|100|0128900000|
**----- End of picture text -----**<br>
DEK 5/6
**A.40**
**A**
**A.41**
**Special terminals - SAKG**
**SAKG 32 I**
**50 mm²**
**A**
## **TS 35 / KrG**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
## **Technical data**
**==> picture [159 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Rated data|
|Rated voltage|V|
|Rated current|A|
|Rated cross-section|mm²|
|Rated impulse voltage / Pollution severity|kV/-|
|Gauge to IEC 60947-1 / UL94 Flammability class|
|Approvals|
|Clamped conductors (H05V/H07V)|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|Note|
**----- End of picture text -----**<br>
32 x 87 x 84.5 **192 / 70 10...70**
**==> picture [117 x 59] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|IEC 60947-7-1|
|IEC|UL|CSA|
|1000|600|600|
|150|165|170|
|50|AWG 6...3/0|AWG 1...2/0|
|8 / 3|
|B11 / 5VA|
**----- End of picture text -----**<br>
**==> picture [54 x 50] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|?|r|u # a|
|Rated connection|
|10...16 / 10...70|
|10...70 / 10...70|
|6.0...12 Nm (M 8)|
|26 /|
**----- End of picture text -----**<br>
## **Ordering data**
**Version Note**
Medium yellow **Note Accessories Screwable cross-connection** 2-pole 3-pole 4-pole **End plate / Partition plate** dark brown Tropical applications dark brown Tropical applications **Cover / warning label** Cover / warning label
## **Accessories**
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|SAKG 32/35 I|10|0637120000|
**----- End of picture text -----**<br>
**==> picture [155 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Type|current|Qty.|Order No.|
|QL 2 SAKG32+70|150 A|5|0194000000|
|QL 3 SAKG32+70|150 A|5|0441500000|
|QL 4 SAKG32+70|150 A|5|0441600000|
|Width|
|EP 2 SAKG46/35 HP/DBR|2 mm|10|0180700000|
|EP 2 SAKG46/35 HP/TF/GE|2 mm|10|0180800000|
|TW SAKG46 HP/DBR/2|2 mm|10|0177100000|
|TW SAKG46 HP/TF/GE/2|2 mm|10|0179900000|
|AH 32 SAKG32|30 mm|5|0326760000|
**----- End of picture text -----**<br>
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
**A.42**
**Special terminals - SAKG**
**SAKG 32 II**
**SAKG 32 II G**
**50 mm²**
**A**
## **TS 35 / KrG**
**50 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS35x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [504 x 354] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|32 x 80 x 53|32 x 80 x 53|
|max. current / max. cond. cross-section|A/mm²|192 / 70|o————_o|192 / 70|o—————_o|
|Max. clamping range|mm²|10...70|10...70|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|1000|600|600|1000|600|600|
|Rated current|A|150|200|170|150|200|170|
|Rated cross-section|mm²|50|AWG 6...3/0|AWG 1...2/0|50|AWG 6...3/0|AWG 1...2/0|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|/ 5VA|/ 5VA|
|Approvals|?|r|u # a|?|r|u # a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Tightening torque range (clamping screw)|6.0...12 Nm (M 8)|6.0...12 Nm (M 8)|
|Stripping length / Blade size|mm/-|
|Note|Conductor connection with cable lugs according to DIN 46234 and DIN|Conductor connection with cable lugs according to DIN 46234 and DIN|
|46235, from 10 .. 70 mm²|46235, from 10 .. 70 mm²|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Medium yellow|SAKG 32/35 II|10|0637320000|SAKG 32/35 II/GW|10|0637420000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAKG32+70|150 A|5|0194000000|QL 2 SAKG32+70|150 A|5|0194000000|
|3-pole|QL 3 SAKG32+70|150 A|5|0441500000|QL 3 SAKG32+70|150 A|5|0441500000|
|4-pole|QL 4 SAKG32+70|150 A|5|0441600000|QL 4 SAKG32+70|150 A|5|0441600000|
|End plate / Partition plate|Width|Width|
|dark brown|EP 2 SAKG46/35 HP/DBR|2 mm|10|0180700000|EP 1 SAKG32/35 HP/DBR|2 mm|10|0180500000|
|Tropical applications|EP 2 SAKG46/35 HP/TF/GE|2 mm|10|0180800000|EP 1 SAKG32/35 HP/TF/GE|2 mm|10|0180600000|
|dark brown|TW SAKG46 HP/DBR/2|2 mm|10|0177100000|TW SAKG28 HP/DBR/2|2 mm|10|0151400000|
|Tropical applications|TW SAKG46 HP/TF/GE/2|2 mm|10|0179900000|TW SAKG28 HP/TF/GE/2|2 mm|10|0164600000|
|Cover / warning label|
|Cover / warning label|AH 32 SAKG32|30 mm|5|0326760000|AH 32 SAKG32|30 mm|5|0326760000|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5
**For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
**A.43**
**Special terminals - SAKG**
**SAKG 70 II G**
**70 mm²**
**A**
## **TS 35 / KrG**
## **SAKG 32 III**
## **50 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
**==> picture [496 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|32 x 94 x 84.5|32 x 84 x 51.4|
|max. current / max. cond. cross-section|A/mm²|192 / 70|o————_o|192 / 95|o—————_o|
|Max. clamping range|mm²|10...70|10...95|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|1000|600|600|1000|600|
|Rated current|A|150|165|185|192|200|
|Rated cross-section|mm²|50|AWG 6...3/0|AWG 1...2/0|70|AWG 6...3/0|AWG 2/0...4/0|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|B11 / 5VA|/ 5VA|
|Approvals|?|r # a|?|r|u # a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|10...16 / 10...70|10...16|
|flexible / Stranded wire with end ferrules|mm²|10...70 / 10...70|
|Tightening torque range (clamping screw)|6.0...12 Nm (M 8)|6.0...12 Nm (M 8)|
|Stripping length / Blade size|mm/-|26 /|
|Note|A tightening torque of 12 Nm must be applied to 50 - 70 mm² stranded|Conductor connection with cable lugs according to DIN 46234 with|
|and AWG 2 - 3/0 7-core connections.|16..95 mm² and DIN 46235 with 10 .. 50 mm²|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering data**
**==> picture [503 x 155] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Medium yellow|SAKG 32/35 III|10|0637220000|SAKG 70/35 II/GW|10|0636620000|
|Note|
|Accessories|
|Screwable cross-connection|Type|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAKG32+70|150 A|5|0194000000|
|3-pole|QL 3 SAKG32+70|150 A|5|0441500000|
|4-pole|QL 4 SAKG32+70|150 A|5|0441600000|
|End plate / Partition plate|Width|Width|
|dark brown|EP 2 SAKG46/35 HP/DBR|2 mm|10|0180700000|EP 1 SAKG32/35 HP/DBR|2 mm|10|0180500000|
|Tropical applications|EP 2 SAKG46/35 HP/TF/GE|2 mm|10|0180800000|EP 1 SAKG32/35 HP/TF/GE|2 mm|10|0180600000|
|dark brown|TW SAKG46 HP/DBR/2|2 mm|10|0177100000|TW SAKG28 HP/DBR/2|2 mm|10|0151400000|
|Tropical applications|TW SAKG46 HP/TF/GE/2|2 mm|10|0179900000|TW SAKG28 HP/TF/GE/2|2 mm|10|0164600000|
|Cover / warning label|
|Cover / warning label|AH 32 SAKG32|30 mm|5|0326760000|AH 32 SAKG32|30 mm|5|0326760000|
**----- End of picture text -----**<br>
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
**A.44**
**Special terminals - SAKG**
**A** |
**==> picture [44 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
SAKG 40 I<br>**----- End of picture text -----**<br>
**95 mm² SAKG 40 II**
**95 mm²**
**SAKG 40 II GW 95 mm²**
|40 x 94 x 84.5||||40 x 90 x 53|40 x 90 x 53|||||40 x 90 x 53|40 x 90 x 53||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**232 / 95**||**232 / 95**<br>o————_o||||o————_o||||**232 / 95**||o—————_o|||
|**10...95**||||**10...95**||||||**10...95**|||||
|IEC 60947-7-1||||IEC 60947-7-1||||||IEC 60947-7-1|||||
|**IEC**|**UL**|**CSA**||**IEC**|**UL**|**CSA**||||**IEC**|**UL**|**CSA**|||
|1000|600||600|1000|600||600|||1000|600||600||
|232|195||250|232|230||250|||232|230||250||
|95<br>AWG 2/0...4/0|AWG 2/0...4/0|AWG 2/0...4/0|AWG 2/0...4/0<br>95||AWG 1...4/0|AWG 2/0...4/0|AWG 2/0...4/0|||95|AWG 1...4/0|AWG 2/0...4/0|AWG 2/0...4/0||
||8 / 3||||8 / 3||||||8 / 3||||
||B12 / 5VA||||/ 5VA|/ 5VA|||||/ 5VA|/ 5VA|||
|? r u# a||||? r u# a||||||? r u# a|||||
|**Rated connection**||||**Rated connection**||||||**Rated connection**|||||
|10...16 / 10...95||||...16||||||...16|||||
|10...95 / 10...95|||||||||||||||
|10...20 Nm(M 10)||||10...20 Nm(M 10|M 10)|||||10...20 Nm(M 10|M 10)||||
|25 /|||||||||||||||
|Conductor connection with cable lugs acc. to DIN 46234 from 10 .. 95||||Conductor connection with cable lugs acc. to DIN 46234 from 10 .. 95<br>Conductor connection with cable lugs according to DIN 46234, from 10||||Conductor connection with cable lugs according to DIN 46234, from 10||Conductor connection with cable lugs according to DIN 46234, from 10||||Conductor connection with cable lugs according to DIN 46234, from 10|
|mm²||||.. 95 mm²||||||.. 95 mm²|||||
||||||||||||||||
|**Type**|||**Qty.**|**Order No.**<br>**Type**|||**Qty.**|**Order No.**||**Type**|||**Qty.**|**Order No.**|
|SAKG 40/35 I|||5|**0637520000**<br>SAKG 40/35 II|||5|**0637720000**||SAKG 40/35 II/GW|||5|**0637820000**|
||||||||||||||||
||||||||||||||||
|**Type**|**current**||**Qty.**<br>**Order No.**<br>**Type**||**current**||**Qty.**|**Order No.**||**Type**|**current**||**Qty.**|**Order No.**|
|QL 2 SAKG40/35|232 A|||5<br>**0211400000**<br>QL 2 SAKG40/35||232 A|5|**0211400000**||QL 2 SAKG40/35||232 A|5|**0211400000**|
|QL 3 SAKG40/35|232 A|||5<br>**0444900000**<br>QL 3 SAKG40/35||232 A|5|**0444900000**||QL 3 SAKG40/35||232 A|5|**0444900000**|
|QL 4 SAKG40/35|232 A|||5<br>**0445000000**<br>QL 4 SAKG40/35||232 A|5|**0445000000**||QL 4 SAKG40/35||232 A|5|**0445000000**|
||**Width**|||||**Width**||||||**Width**|||
|EP 2 SAKG46/35 HP/DBR||2 mm|10<br>**0180700000**<br>EP 2 SAKG46/35 HP/DBR|||2 mm|10|**0180700000**||EP 2 SAKG46/35 HP/DBR||2 mm|10|**0180700000**|
|EP 2 SAKG46/35 HP/TF/GE||2 mm|10<br>**0180800000**<br>EP 2 SAKG46/35 HP/TF/GE|||2 mm|10|**0180800000**||EP 2 SAKG46/35 HP/TF/GE||2 mm|10|**0180800000**|
|TW SAKG46 HP/DBR/2||2 mm|10<br>**0177100000**<br>TW SAKG46 HP/DBR/2|||2 mm|10|**0177100000**||TW SAKG46 HP/DBR/2||2 mm|10|**0177100000**|
|TW SAKG46 HP/TF/GE/2||2 mm|10<br>**0179900000**<br>TW SAKG46 HP/TF/GE/2|||2 mm|10|**0179900000**||TW SAKG46 HP/TF/GE/2||2 mm|10|**0179900000**|
||||||||||||||||
|AH 40 SAKG40|38 mm|||5<br>**0326860000**<br>AH 40 SAKG40||38 mm|5|**0326860000**||AH 40 SAKG40||38 mm|5|**0326860000**|
DEK 5/5
DEK 5/5
DEK 5/5
**A.45**
**Special terminals - SAKG**
**A** .
**SAKG 40 III 95 mm²**
**SAKG 46 II 150 mm²**
## **TS 35 / KrG**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS35x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [509 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|40 x 98 x 84.5|46 x 106 x 57|
|max. current / max. cond. cross-section|A/mm²|232 / 95|353 / 185|
|Max. clamping range|mm²|10...95|10...185|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|1000|600|600|1000|600|600|
|Rated current|A|232|195|230|309|285|365|
|Rated cross-section|mm²|95|AWG 1...4/0|AWG 2/0...4/0|150|AWG 4/0...300|AWG 4...300|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|B12 / 5VA|/ 5VA|
|Approvals|?|r|u # a|?|r|u # a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|10...16 / 10...95|10...16|
|flexible / Stranded wire with end ferrules|mm²|10...95 / 10...95|
|Tightening torque range (clamping screw)|16...20 Nm (M 10)|14...31 Nm M 12|
|Stripping length / Blade size|mm/-|25 /|
|Note|Conductor connection with cable lugs according to DIN 46234, from 10 ..|
|185 mm² and DIN 46235, from 25 .. 150 mm²|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering data**
**==> picture [505 x 155] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Medium yellow|SAKG 40/35 III|5|0637620000|SAKG 46/35 II|5|0637920000|
|Note|
|Accessories|
|Screwable cross-connection|Type|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAKG46|309 A|5|0247000000|
|3-pole|QL 3 SAKG46|309 A|5|0444400000|
|————<——_——|4-pole|QL 4 SAKG46|309 A|5|0444500000|
|End plate / Partition plate|Width|Width|
|dark brown|EP 2 SAKG46/35 HP/DBR|2 mm|10|0180700000|EP 2 SAKG46/35 HP/DBR|2 mm|10|0180700000|
|Tropical applications|EP 2 SAKG46/35 HP/TF/GE|2 mm|10|0180800000|EP 2 SAKG46/35 HP/TF/GE|2 mm|10|0180800000|
|dark brown|TW SAKG46 HP/DBR/2|2 mm|10|0177100000|TW SAKG46 HP/DBR/2|2 mm|10|0177100000|
|Tropical applications|TW SAKG46 HP/TF/GE/2|2 mm|10|0179900000|TW SAKG46 HP/TF/GE/2|2 mm|10|0179900000|
|Cover / warning label|
|Cover / warning label|AH 40 SAKG40|38 mm|5|0326860000|AH 46 SAKG46|46 mm|5|0326960000|
**----- End of picture text -----**<br>
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
**A.46**
**Special terminals - SAKG**
**SAKG 54 II GW**
**A**
## **SAKG 46 II GW**
## **150 mm² SAKG 54 II**
## **240 mm²**
**240 mm²**
|46 x 106 x 57|46 x 106 x 57||||||54 x 122 x 60.5|54 x 122 x 60.5|||||54 x 122 x 60.5|54 x 122 x 60.5||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**353 / 185**||||**415 / 240**<br>Oo—O|||||Oo——_O||||**415 / 240**||o——O|||
|**10...185**|||||||**10...240**||||||**10...240**|||||
|IEC 60947-7-1|||||||IEC 60947-7-1||||||IEC 60947-7-1|||||
|**IEC**|**UL**|||**CSA**|||**IEC**|**UL**|**CSA**||||**IEC**|**UL**|**CSA**|||
|1000|600||||600||1000|600||600|||1000|600||600||
|309|285||||365||415|380||600|||415|380||600||
|150|AWG 4/0...kcmil 300||AWG 1...300|||AWG 1...300|240|kcmil 300...kcmil 500|kcmil 300...kcmil 500||||240|kcmil 300...kcmil 500|kcmil 300...kcmil 500|||
||8 / 3|||||||8 / 3||||||8 / 3||||
||/ 5VA|||||||/ 5VA||||||/ 5VA||||
|? r u# a|||||||? r u# a||||||? r u# a|||||
|**Rated connection**|||||||**Rated connection**||||||**Rated connection**|||||
|10...16||||||||||||||||||
|||||||||||||||||||
|14...31 Nm M 12|14...31 Nm M 12||||||25...60 Nm M 16||||||25...60 Nm M 16|||||
|||||||||||||||||||
|Conductor connection with cable lugs according to DIN 46234, from 10 ..|||||||Conductor connection with cable lugs according to DIN 46234, from 10 ..<br>Conductor connection with cable lugs according to DIN 46234 and DIN||||Conductor connection with cable lugs according to DIN 46234 and DIN||Conductor connection with cable lugs according to DIN 46234 and DIN||||Conductor connection with cable lugs according to DIN 46234 and DIN|
|185 mm² and DIN 46235, from 25 .. 150 mm²||185 mm² and DIN 46235, from 25 .. 150 mm²|185 mm² and DIN 46235, from 25 .. 150 mm²|185 mm² and DIN 46235, from 25 .. 150 mm²|||46235, from 70 .. 240 mm²|46235, from 70 .. 240 mm²|||||46235, from 70 .. 240 mm²|46235, from 70 .. 240 mm²||||
|||||||||||||||||||
|**Type**||||||**Qty.**|**Order No.**<br>**Type**|||**Qty.**|**Order No.**||**Type**|||**Qty.**|**Order No.**|
|SAKG 46/35 II/GW||||||5|**0638020000**<br>SAKG 54/35 II|||5|**0638120000**||SAKG 54/35 II/GW|||5|**0638220000**|
|||||||||||||||||||
|||||||||||||||||||
|**Type**|**current**|||||**Qty.**|**Order No.**<br>**Type**|**current**||**Qty.**|**Order No.**||**Type**|**current**||**Qty.**|**Order No.**|
|QL 2 SAKG46||309 A||309 A||5|**0247000000**<br>QL 2 SAKG54|415 A||5|**0264400000**||QL 2 SAKG54|415 A||5|**0264400000**|
|QL 3 SAKG46||309 A||309 A||5|**0444400000**<br>QL 3 SAKG54|415 A||5|**0408000000**||QL 3 SAKG54|415 A||5|**0408000000**|
|QL 4 SAKG46||309 A||309 A||5|**0444500000**<br>QL 4 SAKG54|415 A||5|**0247400000**||QL 4 SAKG54|415 A||5|**0247400000**|
|||**Width**||||||**Width**||||||**Width**||||
|EP 2 SAKG46/35 HP/DBR|||2 mm|||10|**0180700000**<br>EP 2 SAKG46/35 HP/DBR||2 mm|10|**0180700000**||EP 2 SAKG46/35 HP/DBR||2 mm|10|**0180700000**|
|EP 2 SAKG46/35 HP/TF/GE|||2 mm|||10|**0180800000**<br>EP 2 SAKG46/35 HP/TF/GE||2 mm|10|**0180800000**||EP 2 SAKG46/35 HP/TF/GE||2 mm|10|**0180800000**|
|TW SAKG46 HP/DBR/2|||2 mm|||10|**0177100000**<br>TW SAKG46 HP/DBR/2||2 mm|10|**0177100000**||TW SAKG46 HP/DBR/2||2 mm|10|**0177100000**|
|TW SAKG46 HP/TF/GE/2|||2 mm|||10|**0179900000**<br>TW SAKG46 HP/TF/GE/2||2 mm|10|**0179900000**||TW SAKG46 HP/TF/GE/2||2 mm|10|**0179900000**|
|||||||||||||||||||
|AH 46 SAKG46||46 mm||||5|**0326960000**|||||||||||
DEK 5/5
DEK 5/5
DEK 5/5
**A.47**
**Stud Terminal - KST**
**KST 5/35**
**10 mm² KST 6/35**
**16 mm²**
**A**
## **TS 35 / PA**
|In hazardous area applications, the installation instructions|In hazardous area applications, the installation instructions|In hazardous area applications, the installation instructions||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|and the rated data specifications for accessories given in the|and the rated data specifications for accessories given in the|||||||||||||||||
|technical appendix must be followed.||||||||||||||||||
|Width/Length/height with TS35x7.5||mm|24 x 62.5 x 49.5|24 x 62.5 x 49.5|24 x 62.5 x 49.5||24 x 62.5 x 49.5||||24 x 60 x 54.5|24 x 60 x 54.5||||||
|max. current / max. cond. cross-section<br>Max. clamping range||A/mm²<br>mm²|**57 /**|**57 /**|**57 /**|||o—O|||**76 /**<br>**...**|**76 /**|||O°||O|
|**Technical data**||||||||||||||||||
|**Rated data**||||**IEC**|||**UL**|**CSA**|||**IEC**|||**UL**|**CSA**|||
|Rated voltage||V||1000|||600||600||1000|||600|600|||
|Rated current||A|||57||50||65|||76||65||80||
|Rated cross-section||mm²|||10||AWG 12...6|AWG 8...2||||16|AWG 12...6||AWG 12...6|||
|Rated impulse voltage / Pollution severity||kV/-|||||8 / 3|||||||8 / 3||||
|Gauge to IEC 60947-1 / UL94 Flammabilityclass|||||||/ V2|/ V2||||||/ V2|/ V2|||
|Approvals||#|||||||||r# a|# a||||||
||||**Rated connection**||||||||**Rated connection**|||||||
|Tighteningtorque range(clampingscrew)|||2.0...4.0 Nm|||2.0...4.0 Nm|||||3.0...6.0 Nm||3.0...6.0 Nm|||||
|**Note**||||||||||||||||||
|**Ordering data**||||||||||||||||||
|**Version**|||**Type**||||||**Qty.**<br>**Order No.**||**Type**|||||**Qty.**|**Order No.**|
||TS 35 x 7,5|TS 35 x 7,5|||||||||KST 6/35 M6X22|||||25|**9506940000**|
|TS 35 x 15/2,3|TS 35 x 15/2,3|TS 35 x 15/2,3|KST 5/35 M5X18||||||25<br>**9528300000**|||||||||
|**Note**||||||||||||||||||
|**Accessories**||||||||||||||||||
|**Screwable cross-connection**|||**Type**||||||**Qty.**<br>**Order No.**||**Type**|||**current**||**Qty.**|**Order No.**|
|||2-pole|||||||||QL 2 KST6|QL 2 KST6|||76 A|5|**9501350000**|
|**Partitionplate**||||||||**Width**|||||||**Width**|||
|||left|TW KST5-12 LI/NO 160/HM|TW KST5-12 LI/NO 160/HM|||||10<br>**1752800000**||TW KST5-12 LI/NO 160/HM||TW KST5-12 LI/NO 160/HM|TW KST5-12 LI/NO 160/HM||10|**1752800000**|
|||right|TW KST5-12 RE/NO 160/HM|||TW KST5-12 RE/NO 160/HM|||10<br>**1718530000**||TW KST5-12 RE/NO 160/HM||TW KST5-12 RE/NO 160/HM|TW KST5-12 RE/NO 160/HM||10|**1718530000**|
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
**A.48**
**Stud Terminal - KST**
**A**
|**KST 8/35**||}|}|||||**35 mm²**|**KST 10/35**|**KST 10/35**|**KST 10/35**||||||**70 mm²**||**KST 12/35**|**KST 12/35**||||**95 mm²**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||Wafaavline||3”||||||||oo|||||||||—|oS|||
|24 x 62.5 x 72|24 x 62.5 x 72||||||||34 x 60 x 82|34 x 60 x 82|||||||||34 x 60 x 74.5||||||
|**125 /**||||Oo—O|||||**192 /**|**192 /**|||Oo—O||||||**232 /**|||o—O|||
|**...**|||||||||**...**||||||||||**...**||||||
|**IEC**||**UL**||**CSA**|||||**IEC**|||**UL**|**CSA**||||||**IEC**||**UL**|**CSA**|||
|1000||600|||600||||1000|||600||600|||||1000||600||600||
|125||115|||130||||232|||175||200|||||232||200||250||
|35|AWG 12...2||AWG 12...2|||AWG 12...2||||70|AWG 12...2/0||AWG 12...2/0||AWG 12...2/0||||95|AWG 12...3||...0000|||
|||8 / 3||||||||||8 / 3|8 / 3||||||||8 / 3||||
|||/ V2|/ V2|||||||||/ V2|/ V2||||||||/ V2|/ V2|||
|r# a|||||||||r# a|# a|||||||||#||||||
|**Rated connection**|||||||||**Rated connection**||||||||||**Rated connection**||||||
|6.0...12 Nm|||||||||||||||||||14...31 Nm||||||
||||||||||||||||||||||||||
||||||||||||||||||||||||||
|**Type**|||||**Qty.**|||**Order No.**|**Type**||||||**Qty.**||**Order No.**||**Type**||||**Qty.**|**Order No.**|
|KST 8/35 M8X30||||||25||**9506950000**|KST 10/35 M10X39||||||20||**9506960000**||KST 12/35 M12X37||||20|**9506970000**|
|KST 8/35 M8X30||||||25||**9528320000**|KST 10/35 M10X39||||||20||**9528330000**||KST 12/35 M12X37||||20|**9528340000**|
||||||||||||||||||||||||||
||||||||||||||||||||||||||
|**Type**||**current**||||**Qty.**||**Order No.**|**Type**|||**current**|||**Qty.**||**Order No.**||**Type**||**current**||**Qty.**|**Order No.**|
|QL 2 KST8|||125 A|125 A||5||**9501360000**|QL 2 KST10|QL 2 KST10||||||5|**9501370000**||QL 2 KST12|||232 A|5|**9501380000**|
||||**Width**||||||||||**Width**|||||||||**Width**|||
|TW KST5-12 LI/NO 160/HM||TW KST5-12 LI/NO 160/HM||||10||**1752800000**|TW KST5-12 LI/NO 160/HM||||||10||**1752800000**||TW KST5-12 LI/NO 160/HM||||10|**1752800000**|
|TW KST5-12 RE/NO 160/HM||TW KST5-12 RE/NO 160/HM||||10||**1718530000**|TW KST5-12 RE/NO 160/HM|||TW KST5-12 RE/NO 160/HM|||10||**1718530000**||TW KST5-12 RE/NO 160/HM||TW KST5-12 RE/NO 160/HM||10|**1718530000**|
DEK 5/5
DEK 5/5
DEK 5/5
**A.49**
**Terminals with electronic components**
**DK 4 LD/2**
**A**
## **With electronic components TS 35 / PA**
## **DK 4 LD/1**
## **DC voltage indicator**
## **4 mm²**
## **DC voltage indicator**
## **4 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS35x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
6 x 50 x 52.5 **10 / 4 0.5...4** IEC 60947-7-1
6 x 50 x 52.5 **10 / 4 0.5...4** IEC 60947-7-1 **IEC UL CSA** 24 10 4 1 / 3 A3 / V2 r # 24 / 5 **Rated connection** 0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...1.0 Nm (M 3) 9 / 0.6 x 3.5 mm
## **Technical data**
**==> picture [281 x 216] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Rated data|IEC|UL|CSA|
|Rated voltage|V|24|
|Rated current|A|10|
|Rated cross-section|mm²|4|
|Rated impulse voltage / Pollution severity|kV/-|1 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|
|Approvals|r #|
|Electronic fixtures|
|Diode reverse voltage / Diode current|-|
|Operating voltage for display, min. / Current|V/mA|24 / 5|
|Clamped conductors (H05V/H07V)|Rated connection|
|solid / stranded|mm²|0.5...4 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...4|
|Tightening torque range (clamping screw)|0.5...1.0 Nm (M 3)|
|Stripping length / Blade size|mm/-|9 / 0.6 x 3.5 mm|
|Note|
|Ordering datag data data|
|Version|Typeypee|Qty.|
|Red LED|
|Green LED|DK 4/35 LD GR 24VDC|
|Neon lampp|
|Note|
**----- End of picture text -----**<br>
## **Ordering datag data data**
**==> picture [155 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Typeypee|Qty.|Order No.|
|DK 4/35 LD GR 24VDC|25|0395460000|
**----- End of picture text -----**<br>
**==> picture [155 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|DK 4/35 LD GR 24VDC|25|0395760000|
**----- End of picture text -----**<br>
Red LED Green LED Neon lampp 2-polepoleole 3-polepoleole 4-polepoleole 10-polepoleole 2-polepoleole 3-polepoleole 4-polepoleole Switchable link Connecting sleeveg sleeve sleeve Mounting screwg screw screw Test plugpluglugg Socket beigegee Small partitionpartitionartition
## **Accessories**
**==> picture [503 x 264] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-polepoleole|Q 2 AKZ4|32 A|50|0336400000|Q 2 AKZ4|32 A|50|0336400000|
|3-polepoleole|Q 3 AKZ4|32 A|50|0336500000|Q 3 AKZ4|32 A|50|0336500000|
|4-polepoleole|Q 4 AKZ4|32 A|50|0336600000|Q 4 AKZ4|32 A|50|0336600000|
|10-polepoleole|
|External cross-connection|
|2-polepoleole|QB 2 WI RA6 IS|27 A|50|0482700000|QB 2 WI RA6 IS|27 A|50|0482700000|
|3-polepoleole|QB 3 WI RA6 IS|27 A|50|0482800000|QB 3 WI RA6 IS|27 A|50|0482800000|
|4-polepoleole|QB 4 WI RA6 IS|27 A|50|0482900000|QB 4 WI RA6 IS|27 A|50|0482900000|
|Switchable link|
|Switchable link|VL 2 AKZ4/DK4|50|0446700000|VL 2 AKZ4/DK4|50|0446700000|
|Connecting sleeveg sleeve sleeve|VH 10/4/2.8 AKZ4|50|0446600000|VH 10/4/2.8 AKZ4|50|0446600000|
|Mounting screwg screw screw|BFSC M2.5X14 SAKD2.5N|100|0266800000|BFSC M2.5X14 SAKD2.5N|100|0266800000|
|Testing / Checking|Width|Width|
|Test plugpluglugg|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|End plate / Partition plate|
|beigegee|AP DK4|1.5 mm|20|0359260000|AP DK4|1.5 mm|20|0359260000|
|Small partition|
|Small partitionpartitionartition|TSCH 4 AKZ4|6 mm|100|0363360000|TSCH 4 AKZ4|6 mm|100|0363360000|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/6|DEK 5/6|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
**A.50**
**Terminals with electronic components**
**A**
**==> picture [509 x 373] intentionally omitted <==**
**----- Start of picture text -----**<br>
DK 4 LD/3 4 mm² DK 4 LD/4 4 mm² DK 4 LD/5 4 mm²<br>DC voltage indicator DC voltage indicator AC voltage indicator<br>6 x 50 x 52.5 6 x 50 x 52.5 6 x 50 x 52.5<br>10 / 4 10 / 4 10 / 4<br>0.5...4 0.5...4 0.5...4<br>IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1<br>IEC UL CSA IEC UL CSA IEC UL CSA<br>24 24 24<br>10 10 10<br>4 4 4<br>1 / 3 1 / 3 1 / 3<br>A3 / V2 A3 / V2 A3 / V2<br># # #<br>24 / 5 24 / 5 24 / 5<br>Rated connection Rated connection Rated connection<br>0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...4 / 0.5...4<br>0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...4 / 0.5...4<br>0.5...1.0 Nm (M 3) 0.5...1.0 Nm (M 3) 0.5...1.0 Nm (M 3)<br>9 / 0.6 x 3.5 mm 9 / 0.6 x 3.5 mm 9 / 0.6 x 3.5 mm<br>Type Qty. Order No. Type Qty. Order No. Type Qty. Order No.<br>DK 4/35 LD ROT 24VDC 25 0210260000 DK 4/35 LD 1D ROT 24VAC 25 0395960000<br>**----- End of picture text -----**<br>
|**Typeypee**|**Qty.y..**<br>**Order No.**||**Typeypee**|**Qty.y..**|**Order No.**|
|---|---|---|---|---|---|
|DK 4/35 LD ROT 24VDC|25<br>**0210260000**|||||
|DK 4/35 LD GR 24VDC|25<br>**0210460000**||DK 4/35 LD GR 24VDC|25|**0210060000**|
|||||||
|||||||
|||||||
|**Type**|**current**<br>**Qty.**<br>**Order No.**||**Type**|**current**<br>**Qty.**|**Order No.**|
|Q 2 AKZ4|32 A<br>50<br>**0336400000**||Q 2 AKZ4|32 A<br>50|**0336400000**|
|Q 3 AKZ4|32 A<br>50<br>**0336500000**||Q 3 AKZ4|32 A<br>50|**0336500000**|
|Q 4 AKZ4|32 A<br>50<br>**0336600000**||Q 4 AKZ4|32 A<br>50|**0336600000**|
|||||||
|||||||
|QB 2 WI RA6 IS|27 A<br>50<br>**0482700000**||QB 2 WI RA6 IS|27 A<br>50|**0482700000**|
|QB 3 WI RA6 IS|27 A<br>50<br>**0482800000**||QB 3 WI RA6 IS|27 A<br>50|**0482800000**|
|QB 4 WI RA6 IS|27 A<br>50<br>**0482900000**||QB 4 WI RA6 IS|27 A<br>50|**0482900000**|
|||||||
|VL 2 AKZ4/DK4|32 A<br>50<br>**0446700000**||VL 2 AKZ4/DK4|32 A<br>50|**0446700000**|
|VH 10/4/2.8 AKZ4|50<br>**0446600000**||VH 10/4/2.8 AKZ4|50|**0446600000**|
|BFSC M2.5X14 SAKD2.5N|100<br>**0266800000**||BFSC M2.5X14 SAKD2.5N|100|**0266800000**|
||**Width**|||**Width**||
|PS 2.3 RT|5.4 mm<br>20<br>**0180400000**||PS 2.3 RT|5.4 mm<br>20|**0180400000**|
|STB 8.5/D4/2.3/M2.5 AKZ|50<br>**0215700000**||STB 8.5/D4/2.3/M2.5 AKZ|50|**0215700000**|
|||||||
|AP DK4|1.5 mm<br>20<br>**0359260000**||AP DK4|1.5 mm<br>20|**0359260000**|
|||||||
|TSCH 4 AKZ4|6 mm<br>100<br>**0363360000**||TSCH 4 AKZ4|6 mm<br>100|**0363360000**|
|**Type**|**current**|**Qty.**|**Order No.**|
|---|---|---|---|
|Q 2 AKZ4|32 A|50|**0336400000**|
|Q 3 AKZ4|32 A|50|**0336500000**|
|Q 4 AKZ4|32 A|50|**0336600000**|
|||||
|||||
|QB 2 WI RA6 IS|27 A|50|**0482700000**|
|QB 3 WI RA6 IS|27 A|50|**0482800000**|
|QB 4 WI RA6 IS|27 A|50|**0482900000**|
|||||
|VL 2 AKZ4/DK4|32 A|50|**0446700000**|
|VH 10/4/2.8 AKZ4||50|**0446600000**|
|BFSC M2.5X14 SAKD2.5N||100|**0266800000**|
||**Width**|||
|PS 2.3 RT|5.4 mm|20|**0180400000**|
|STB 8.5/D4/2.3/M2.5 AKZ||50|**0215700000**|
|||||
|AP DK4|1.5 mm|20|**0359260000**|
|||||
|TSCH 4 AKZ4|6 mm|100|**0363360000**|
DEK 5/6
DEK 5/6
DEK 5/6
**A.51**
**Terminals with electronic components**
**A**
## **With electronic components TS 35 / PA**
**DK 4 GL I**
**4 mm²**
## **Current indicator**
**==> picture [159 x 60] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|In hazardous area applications, the installation instructions|
|and the rated data specifications for accessories given in the|
|technical appendix must be followed.|
|Width/Length/height with TS35x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [109 x 181] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|6 x 50 x 52.5|
|/ 4|
|0.33...4|
|IEC|UL|CSA|
|250|
|10|
|4|
|1 / 3|
|A3 / V2|
|#|
|3 / 1|
|Rated connection|
|0.5...4 / 0.5...4|
|0.5...4 / 0.5...4|
|0.5...1.0 Nm (M 3)(M 3)M 3))|
|9 / 0.6 x 3.5 mm|
**----- End of picture text -----**<br>
## **Technical data**
**==> picture [331 x 510] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Rated data|IEC|UL|CSA|
|Rated voltage|V|250|
|Rated current|A|10|
|Rated cross-section|mm²|4|
|Rated impulse voltage / Pollution severity|kV/-|1 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|
|Approvals|#|
|Electronic fixtures|
|Diode reverse voltage / Diode current|-|
|Operating voltage for display, min. / Current|V/A|3 / 1|
|Clamped conductors (H05V/H07V)|Rated connection|
|solid / stranded|mm²|0.5...4 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...4|
|Tightening torque range (clamping screw)|0.5...1.0 Nm (M 3)(M 3)M 3))|
|Stripping length / Blade size|mm/-|9 / 0.6 x 3.5 mm|
|Note|
|Ordering data|
|Version|Type|Qty.|Order No.|
|Red LED|
|Green LED|
|Neon lamp|DK 4/35 GL 1D I1,0A|25|1111160000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|
|2-pole|Q 2 AKZ4|32 A|50|0336400000|
|3-pole|Q 3 AKZ4|32 A|50|0336500000|
|4-pole|Q 4 AKZ4|32 A|50|0336600000|
|10-pole|Q 10 AKZ4|32 A|20|0368600000|
|External cross-connection|
|2-pole|QB 2 WI RA6 IS|27 A|50|0482700000|
|3-pole|QB 3 WI RA6 IS|27 A|50|0482800000|
|4-pole|QB 4 WI RA6 IS|27 A|50|0482900000|
|Switchable link|
|Switchable link|VL 2 AKZ4/DK4|32 A|50|0446700000|
|Connecting sleeve|VH 10/4/2.8 AKZ4|50|0446600000|
|Mounting screw|BFSC M2.5X14 SAKD2.5N|100|0266800000|
|Testing / Checking|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|End plate / Partition plate|
|beige|AP DK4|1.5 mm|20|0359260000|
|Small partition|
|Small partition|TSCH 4 AKZ4|6 mm|100|0363360000|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/6|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
**A.52**
**Terminals with electronic components**
**A** |
## **With electronic components TS 35 / PA**
## **DK 4 D/1**
## **4 mm²**
**Diode terminal, e.g. as reverse polarity protection**
**DK 4 D/2 4 mm²**
**Suppressor circuit for contactor and solenoid valve (DC voltage)**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
## **Technical data**
**==> picture [159 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Rated data|
|Rated voltage|V|
|Rated current|A|
|Rated cross-section|mm²|
|Rated impulse voltage / Pollution severity|kV/-|
|Gauge to IEC 60947-1 / UL94 Flammability class|
|Approvals|
|Electronic fixtures|
|Diode reverse voltage / Diode current|A|
|Operating voltage for display, min. / Current|-/A|
|Clamped conductors (H05V/H07V)|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|Note|
**----- End of picture text -----**<br>
**==> picture [293 x 194] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|6 x 50 x 52.5|6 x 50 x 52.5|
|10 / 4|10 / 4|
|0.33...4|O——_#—_|0.33...4|_|
|IEC|UL|CSA|IEC|UL|CSA|
|380|300|380|300|
|10|10|10|10|
|4|AWG 22...12|4|AWG 22...12|
|/ 3|/ 3|
|A3 / V2|A3 / V2|
|#|r #|
|1000 / 1|1000 / 1|
|Rated connection|Rated connection|
|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|0.5...0.8 Nm (M 3)|0.5...0.8 Nm (M 3)|
|9 / 0.6 x 3.5 mm|9 / 0.6 x 3.5 mm|
|Diode current: max 1A. (1 N 4007)|Diode current: max 1A. (1 N 4007)|
**----- End of picture text -----**<br>
## **Ordering data**
**==> picture [155 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|DK 4/35 1D GET.SCH.|25|0396360000|
**----- End of picture text -----**<br>
**==> picture [155 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|DK 4/35 1D A1|25|0538960000|
|DK 4/35 1D A1 BL|25|0538980000|
**----- End of picture text -----**<br>
**Version Note**
Red LED Green LED 2-polepoleole 3-polepoleole 4-polepoleole 2-polepoleole 3-polepoleole 4-polepoleole Switchable link Connecting sleeveg sleeve sleeve Mounting screwg screw screw Test plugpluglugg Socket beigegee Small partitionpartitionartition
## **Accessories**
**==> picture [503 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-polepoleole|Q 2 AKZ4|32 A|50|0336400000|Q 2 AKZ4|32 A|50|0336400000|
|3-polepoleole|Q 3 AKZ4|32 A|50|0336500000|Q 3 AKZ4|32 A|50|0336500000|
|4-polepoleole|Q 4 AKZ4|32 A|50|0336600000|Q 4 AKZ4|32 A|50|0336600000|
|External cross-connection|
|2-polepoleole|QB 2 WI RA6 IS|27 A|50|0482700000|QB 2 WI RA6 IS|27 A|50|0482700000|
|3-polepoleole|QB 3 WI RA6 IS|27 A|50|0482800000|QB 3 WI RA6 IS|27 A|50|0482800000|
|4-polepoleole|QB 4 WI RA6 IS|27 A|50|0482900000|QB 4 WI RA6 IS|27 A|50|0482900000|
|Switchable link|
|Switchable link|VL 2 AKZ4/DK4|32 A|50|0446700000|VL 2 AKZ4/DK4|50|0446700000|
|Connecting sleeveg sleeve sleeve|VH 10/4/2.8 AKZ4|50|0446600000|VH 10/4/2.8 AKZ4|50|0446600000|
|Mounting screwg screw screw|BFSC M2.5X14 SAKD2.5N|100|0266800000|BFSC M2.5X14 SAKD2.5N|100|0266800000|
|Testing / Checking|Width|Width|
|Test plugpluglugg|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|End plate / Partition plate|
|beigegee|AP DK4|1.5 mm|20|0359260000|AP DK4|1.5 mm|20|0359260000|
|Small partition|
|Small partitionpartitionartition|TSCH 4 AKZ4|6 mm|100|0363360000|TSCH 4 AKZ4|6 mm|100|0363360000|
**----- End of picture text -----**<br>
**==> picture [159 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
DEK 5/6
DEK 5/6
**A.53**
**Terminals with electronic components**
**DK 4 D/4 4 mm²**
**A**
## **With electronic components TS 35 / PA**
## **DK 4 D/3**
## **4 mm²**
**Suppressor circuit for contactor and solenoid valve (DC voltage)**
**Diode terminal for lamp test circuits**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
**==> picture [455 x 194] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|6 x 50 x 52.5|6 x 50 x 52.5|
|max. current / max. cond. cross-section|A/mm²|10 / 4|10 / 4|
|Max. clamping range|mm²|0.33...4|0.33...4|
|Technical data|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|380|300|380|300|
|Rated current|A|10|10|10|10|
|Rated cross-section|mm²|4|4|
|Rated impulse voltage / Pollution severity|kV/-|/ 3|/ 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|A3 / V2|
|Approvals|r #|#|
|Electronic fixtures|
|Diode reverse voltage / Diode current|A|1000 / 1|1000 / 1|
|Operating voltage for display, min. / Current|-/A|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|Tightening torque range (clamping screw)|0.5...0.8 Nm (M 3)|0.5...0.8 Nm (M 3)|
|Stripping length / Blade size|mm/-|9 / 0.6 x 3.5 mm|9 / 0.6 x 3.5 mm|
|Note|Diode current: max 1A. (1 N 4007)|Diode current: max 1A. (1 N 4007)|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering data**
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|DK 4/35 1D A2|25|0538860000|
**----- End of picture text -----**<br>
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|DK 4/35 2D GET.SCH. A1|25|0396660000|
**----- End of picture text -----**<br>
**Version Note**
Red LED Green LED 2-polepoleole 3-polepoleole 4-polepoleole 2-polepoleole 3-polepoleole 4-polepoleole Switchable link Connecting sleeveg sleeve sleeve Mounting screwg screw screw Test plugpluglugg Socket beigegee Small partitionpartitionartition
## **Accessories**
**==> picture [503 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-polepoleole|Q 2 AKZ4|32 A|50|0336400000|Q 2 AKZ4|32 A|50|0336400000|
|3-polepoleole|Q 3 AKZ4|32 A|50|0336500000|Q 3 AKZ4|32 A|50|0336500000|
|4-polepoleole|Q 4 AKZ4|32 A|50|0336600000|Q 4 AKZ4|32 A|50|0336600000|
|External cross-connection|
|2-polepoleole|QB 2 WI RA6 IS|27 A|50|0482700000|QB 2 WI RA6 IS|27 A|50|0482700000|
|3-polepoleole|QB 3 WI RA6 IS|27 A|50|0482800000|QB 3 WI RA6 IS|27 A|50|0482800000|
|4-polepoleole|QB 4 WI RA6 IS|27 A|50|0482900000|QB 4 WI RA6 IS|27 A|50|0482900000|
|Switchable link|
|Switchable link|VL 2 AKZ4/DK4|50|0446700000|VL 2 AKZ4/DK4|32 A|50|0446700000|
|Connecting sleeveg sleeve sleeve|VH 10/4/2.8 AKZ4|50|0446600000|VH 10/4/2.8 AKZ4|50|0446600000|
|Mounting screwg screw screw|BFSC M2.5X14 SAKD2.5N|100|0266800000|BFSC M2.5X14 SAKD2.5N|100|0266800000|
|Testing / Checking|Width|Width|
|Test plugpluglugg|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|End plate / Partition plate|
|beigegee|AP DK4|1.5 mm|20|0359260000|AP DK4|1.5 mm|20|0359260000|
|Small partition|
|Small partitionpartitionartition|TSCH 4 AKZ4|6 mm|100|0363360000|TSCH 4 AKZ4|6 mm|100|0363360000|
**----- End of picture text -----**<br>
**==> picture [159 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
DEK 5/6
DEK 5/6
**A.54**
**Terminals with electronic components**
**DK 4 D/5 4 mm²**
**A**
**Diode terminal for lamp test circuits**
**DK 4 D/6 4 mm²**
**Diode terminal for lamp test circuits**
**DK 4 D/7 4 mm² Diode terminal for lamp test circuits, with protective resistor**
**==> picture [283 x 194] intentionally omitted <==**
**----- Start of picture text -----**<br>
6 x 50 x 52.5 6 x 50 x 52.5<br>10 / 4 10 / 4<br>0.33...4 0.33...4<br>IEC UL CSA IEC UL CSA<br>380 300 380 300<br>10 10 10 10<br>4 4<br> / 3 / 3<br>A3 / V2 A3 / V2<br># #<br>1000 / 1 1000 / 1<br>Rated connection Rated connection<br>0.5...4 / 0.5...4 0.5...4 / 0.5...4<br>0.5...4 / 0.5...4 0.5...4 / 0.5...4<br>0.5...0.8 Nm (M 3) 0.5...0.8 Nm (M 3)<br>9 / 0.6 x 3.5 mm 9 / 0.6 x 3.5 mm<br>Diode current: max 1A. (1 N 4007) Diode current: max 1A. (1 N 4007)<br>**----- End of picture text -----**<br>
**==> picture [109 x 128] intentionally omitted <==**
**----- Start of picture text -----**<br>
6 x 50 x 52.5<br>10 / 4<br>0.33...4<br>IEC UL CSA<br>24 300<br>10 10<br>4<br> / 3<br>A3 / V2<br>#<br> / 1<br>**----- End of picture text -----**<br>
## **Rated connection**
**==> picture [155 x 91] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|0.5...4 / 0.5...4|
|0.5...4 / 0.5...4|
|0.5...0.8 Nm (M 3)|
|9 / 0.6 x 3.5 mm|
|Diode current: max 1A. (1 N 4007)|
|Typeypee|Qty.y..|Order No.|
|DK 4/35 1D 1K5 GET.SCH|25|0396960000|
**----- End of picture text -----**<br>
**==> picture [503 x 238] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|Type|Qty.|Order No.|Type|Qty.|Order No.|Typeypee|Qty.y..|Order No.|
|DK 4/35 2D GET.SCH. A2|25|0396860000|DK 4/35 2D GET.SCH. A1|25|0396760000|DK 4/35 1D 1K5 GET.SCH|25|0396960000|
|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|Q 2 AKZ4|32 A|50|0336400000|Q 2 AKZ4|32 A|50|0336400000|Q 2 AKZ4|32 A|50|0336400000|
|Q 3 AKZ4|32 A|50|0336500000|Q 3 AKZ4|32 A|50|0336500000|Q 3 AKZ4|32 A|50|0336500000|
|Q 4 AKZ4|32 A|50|0336600000|Q 4 AKZ4|32 A|50|0336600000|Q 4 AKZ4|32 A|50|0336600000|
|QB 2 WI RA6 IS|27 A|50|0482700000|QB 2 WI RA6 IS|27 A|50|0482700000|QB 2 WI RA6 IS|27 A|50|0482700000|
|QB 3 WI RA6 IS|27 A|50|0482800000|QB 3 WI RA6 IS|27 A|50|0482800000|QB 3 WI RA6 IS|27 A|50|0482800000|
|QB 4 WI RA6 IS|27 A|50|0482900000|QB 4 WI RA6 IS|27 A|50|0482900000|QB 4 WI RA6 IS|27 A|50|0482900000|
|VL 2 AKZ4/DK4|32 A|50|0446700000|VL 2 AKZ4/DK4|32 A|50|0446700000|VL 2 AKZ4/DK4|50|0446700000|
|VH 10/4/2.8 AKZ4|50|0446600000|VH 10/4/2.8 AKZ4|50|0446600000|VH 10/4/2.8 AKZ4|50|0446600000|
|BFSC M2.5X14 SAKD2.5N|100|0266800000|BFSC M2.5X14 SAKD2.5N|100|0266800000|BFSC M2.5X14 SAKD2.5N|100|0266800000|
|Width|Width|Width|
|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|AP DK4|1.5 mm|20|0359260000|AP DK4|1.5 mm|20|0359260000|AP DK4|1.5 mm|20|0359260000|
|TSCH 4 AKZ4|6 mm|100|0363360000|TSCH 4 AKZ4|6 mm|100|0363360000|TSCH 4 AKZ4|6 mm|100|0363360000|
**----- End of picture text -----**<br>
DEK 5/6
DEK 5/6
DEK 5/6
**A.55**
**Terminals with electronic components**
**A** :
**DK 4 PT 100**
## **With electronic components DK 4 RC 4 mm² TS 35 / PA Terminal with RC combination**
**4 mm²**
**Diode terminal for central control and com-**
**munication system**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
18 x 50 x 52.5 6 x 65 x 53.5 **/ 4 10 / 4** in **0.33...4 0.33...4 IEC UL CSA IEC UL CSA** 230 400 10 10 4 4 / 3 A3 / V2 # #
## **Technical data**
**==> picture [511 x 411] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|230|400|
|Rated current|A|10|10|
|Rated cross-section|mm²|4|4|
|Rated impulse voltage / Pollution severity|kV/-|/ 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|
|Approvals|#|#|
|Electronic fixtures|
|Diode reverse voltage / Diode current|-|
|Operating voltage for display, min. / Current|-/A|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...4|0.5...4 / 0.5...2.5|
|Tightening torque range (clamping screw)|0.5...0.8 Nm (M 3)|0.4...0.7 Nm (M 2.5)|
|Stripping length / Blade size|mm/-|9 / 0.6 x 3.5 mm|6 / 0.6 x 3.5 mm|
|Note|
|Ordering data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Red LED|DK 4/35 RC 220R/220N|5|0053160000|DKT 4/35 PT100|10|8014720000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|Q 2 AKZ4|32 A|50|0336400000|Q 2 AKZ4|32 A|50|0336400000|
|3-pole|Q 3 AKZ4|32 A|50|0336500000|Q 3 AKZ4|32 A|50|0336500000|
|4-pole|Q 4 AKZ4|32 A|50|0336600000|Q 4 AKZ4|32 A|50|0336600000|
|10-pole|Q 10 AKZ4|32 A|20|0368600000|
|External cross-connection|tt|St|=|==—h|
|2-pole|QB 2 WI RA6 IS|27 A|50|0482700000|
|3-pole|QB 3 WI RA6 IS|27 A|50|0482800000|
|4-pole|QB 4 WI RA6 IS|27 A|50|0482900000|
|Switchable link|
|Switchable link|VL 2 AKZ4/DK4|32 A|50|0446700000|
|Connecting sleeve|VH 10/4/2.8 AKZ4|50|0446600000|
|Mounting screw|BFSC M2.5X14 SAKD2.5N|100|0266800000|
|Testing / Checking|Width|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|End plate / Partition plate|
|beige|AP DK4|1.5 mm|20|0359260000|AP DKT4 PA|1.5 mm|20|0687560000|
|End bracket|
|Dark beige Wemid|EW 35|8.5 mm|50|0383560000|
**----- End of picture text -----**<br>
**==> picture [159 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
**==> picture [197 x 20] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|DEK 6|DEK 5/6|
|End plate|
|AP DK4: 0359260000|
**----- End of picture text -----**<br>
**A.56**
**Earth conductor isolating terminals**
**A**
## **SAKT E/35**
## **6 mm²**
## **neon lamp**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
|Width/Length/height with TS35x7.5|mm|16 x 65 x 52.5|||
|---|---|---|---|---|
|max. current / max. cond. cross-section|A/mm²|**27 / 10**|||
|Max. clamping range|mm²|**0.5...10**|||
|**Technical data**<br>~~et~~|~~et~~|~~et~~|~~et~~||
|**Rated data**<br>Rated voltage<br>Rated current<br>~~et~~|V<br>A<br>~~et~~|**IEC**<br>**UL**<br>**CSA**<br>115<br>27<br>~~et~~<br>~~SSS~~<br>~~=~~<br>~~as~~|||
|Rated cross-section|mm²|6|||
|Rated impulse voltage / Pollution severity|kV/-|/ 3|/ 3||
|Gauge to IEC 60947-1 / UL94 Flammabilityclass||A5 / 5VA|A5 / 5VA||
|Approvals<br>**Clamped conductors(H05V/H07V)**||**Rated connection**|||
|solid / stranded|mm²|0.5...10|||
|flexible / Stranded wire with end ferrules|mm²|0.5...6 / 0.5...6|||
|Tighteningtorque range(clampingscrew)||0.8...1.6 Nm(M 3.5)|||
|Strippinglength / Blade size|mm/-|12 / 4.0 x 0.8 mm|||
|**Note**|||||
## **Technical data**
## **Operating mode**
## **SAKT E**
- Slide link is closed
- Auxiliary circuit is **earthed**
- Display is illuminated green
## **Test position**
When measuring insulation resistance with voltages greater than UNom, the earth connection must first be disconnected.
## **Ordering data**
## **SAKT E**
|**Version**|**Type**<br>**Qty.**<br>**Order No.**<br>~~a~~|**Type**<br>**Qty.**<br>**Order No.**<br>~~a~~||
|---|---|---|---|
|20...30 V~<br>40...60V~<br>80...120 V~<br>115 V~<br>230 V~|SAKT E/35 2LD 30VAC<br>5<br>**1166820000**<br>SAKT E/35 2LD 60VAC<br>5<br>**0197920000**<br>SAKT E/35 2LD 120VAC<br>5<br>**0198220000**<br>SAKT E/35 2GL 115VAC<br>5<br>**0198020000**<br>SAKT E/35 2GL 230VAC<br>5<br>**0198120000**<br>~~_~~<br>~~si‘(i‘é;‘_‘a‘(aéalté‘i‘i‘<é“aell—lUR———__~~<br>~~—~~<br>~~a~~<br>~~ee~~<br>~~|~~<br>~~es~~<br>~~==—h ltl~~|||
|**Note**||||
|**Accessories**||||
|**End bracket**|**Type**<br>**Width**<br>**Qty.**|**Order No.**||
|Dark beige Wemid|EW 35<br>8.5 mm<br>50|**0383560000**||
## **Accessories**
- Slide link is opened
- Auxiliary circuit is **not earthed**
- **No** earth fault
- Display illuminated green and red with reduced intensity
- Disconnected earth connection -> When measuring insulation resistance with voltages greater than UNom, the earth connection must be disconnected.
## **Operational malfunction**
## **SAKT E**
- Slide link is opened
- Auxiliary circuit is **not earthed**
- **Earth fault**
(see assortment in catalogue 7)
**For detailed information on other accessories and applications, refer to the „Accessories“ section**
To safe the test sockets use the SD-blade or bits with pilots!
- Display is illuminated red
**A.57**
**A**
**A.58**
**Contents**
## SAK-Series TS 32
## **SAK-Series TS 32**
|**Feed-through terminal**||
|---|---|
|TS 32 / PA|B.2|
|TS 32 / KrG|B.6|
|**Two-tier modular terminals**||
|TS 32 / PA|B.10|
|**Modular PE terminals**||
|TS 32 / PA|B.12|
|TS 32|B.14|
|**Disconnect terminals**||
|TS 32 / PA|B.16|
|TS 32 / KrG|B.18|
|**Fuse terminals**||
|TS 32 / PA|B.20|
|TS 32 / KrG|B.22|
|Fuse inserts and gauge rings for Weidmüller fuse terminals|B.26|
|**Terminals with spring-loaded cable clamps**||
|TS 32|B.28|
|**Test-disconnect terminals**||
|TS 32 / KrG|B.30|
|**Terminals for temperature measuring circuits**||
|TS 32 / PA|B.34|
|**Terminals with screw-less connections**||
|With push-on connection TS 32 / PA|B.36|
|With Termi-Point / Wire-Wrap connection TS 32 / PA|B.38|
|With solder connection TS 32 / PA|B.39|
|With push-on connection TS 32 / KrG|B.42|
|With solder connection TS 32 / KrG|B.45|
|**Special terminals – SAKG**||
|TS 32 / KrG|B.46|
|**Stud terminal – KST**||
|TS 32 / PA|B.54|
|**Terminals with electronic components**||
|With indication|B.56|
|With diodes|B.58|
|With electronic components|B.61|
|**Earth conductor isolating terminals**|B.62|
**B**
**B.1**
**Feed-through terminal**
**SAKD 2.5N**
**SAK 2.5**
**2.5 mm²**
**B** __
## **TS 32 / PA**
## **2.5 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [507 x 563] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|5 x 32.5 x 43.5|6 x 36.5 x 46.5|
|max. current / max. cond. cross-section|A/mm²|30 / 4|41 / 6|
|Max. clamping range|mm²|0.08...4|0.13...6|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|Ex e II|T|II 2 G D|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|EN 60079-7|
|Rated voltage|V|500|300|300|800|600|600|550|
|Rated current|A|24|20|20|24|20|25|21|
|Rated cross-section|mm²|2.5|AWG 28...12|AWG 22...12|2.5|AWG 22...12|AWG 26...10|2.5|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A2 / V2|A3 / V2|
|Approvals|?|r|u|# ~ a|?|r|u|# i a|KEMA 97ATEX1798 U|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...4 / 0.5...2.5|0.5...6 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...2.5|0.5...4 / 0.5...4|
|Tightening torque range (clamping screw)|0.4...0.6 Nm (M 2.5)|0.4...0.6 Nm (M 2.5)|
|Stripping length / Blade size|mm/-|10 / 0.6 x 3.5 mm|10 / 0.6 x 3.5 mm|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|mm²|0.5...0.75|0.5...1.5|
|flexible / Stranded wire with end ferrules|mm²|0.5...0.75 / 0.5...0.75|0.5...1.5|
|Note|With twin ferrules ZH 0.5 to ZH 1.5, rated voltage is 690 V.|With twin ferrules ZH 0.5 to ZH 1.5, rated voltage is 690 V.|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|beige|SAKD 2.5N|100|0215560000|SAK 2.5|100|0279660000|
|Blue|SAKD 2.5N BL|100|0215580000|SAK 2.5 BL|100|0279680000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|Q 2 SAKD2.5N|24 A|50|0367800000|Q 2 SAK2.5|41 A|50|0337000000|
|3-pole|Q 3 SAKD2.5N|24 A|50|0367900000|Q 3 SAK2.5|41 A|50|0337100000|
|4-pole|Q 4 SAKD2.5N|24 A|50|0368000000|Q 4 SAK2.5|41 A|50|0337200000|
|10-pole|Q 10 SAKD2.5N|24 A|20|0368100000|Q 10 SAK2.5|41 A|20|0368700000|
|Connecting sleeve|
|Mounting screw|
|Lock washer|
|Switchable link|
|Switchable link|
|Connecting sleeve|
|Mounting screw|
|Testing / Checking|Width|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/5/2.3/M3 SAK2.5|50|0280600000|
|End plate / Partition plate|
|beige|AP SAKD2.5N|1.5 mm|20|0150960000|AP SAK2.5|1.5 mm|20|0279560000|
|Blue|AP SAKD2.5N BL|1.5 mm|20|0150980000|AP SAK2.5 BL|1.5 mm|20|0279580000|
|beige|TW SAKD2.5N|1.5 mm|20|0191860000|TW SAK2.5|2.5 mm|20|0302860000|
|Blue|TW SAKD2.5N BL|1.5 mm|20|0191880000|TW SAK2.5 BL|1.5 mm|20|0302880000|
|Small partition|
|Small partition|TSCH 3 SAKD2.5 N|5 mm|100|0366860000|TSCH 1|2 mm|100|0319160000|
|Cover / warning label|
|Cover / warning label|AD 3 SAK2.5|50|0297900000|
|Mounting screw (plastic)|BFSC M3X22 PA/RT|100|0128900000|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/5 / SCHT 7|DEK 5/6 / SCHT 7|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
## **Accessories**
**B.2**
**Feed-through terminal**
**SAK 4**
**4 mm² SAK 6 N**
**SAK 10**
**B**
## **6 mm²**
**10 mm²**
|6.5 x 40 x 51.5|6.5 x 40 x 51.5|||||||8 x 40 x 51.5|8 x 40 x 51.5|||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**41 / 6**||||||||**57 / 10**||||||
|**0.13...6**||||||||**0.33...10**||||||
|IEC 60947-7-1||||Ex e IIT II 2 G D||||IEC 60947-7-1|||Ex e IIT II 2 G D|||
|**IEC**||**UL**||**CSA**||**EN 60079-7**||**IEC**||**UL**|**CSA**||**EN 60079-7**|
|800||600||600||550||800||600|600||550|
|32||20||36||28||41||40|47||36|
|4|AWG 22...12|||AWG 26...10||4||6|AWG 22...8||AWG 20...8||6|
||||8 / 3|||||||8 / 3||||
||||A4 / V2|||||||A5 / V2||||
|? r u #i ~ a||||KEMA 97ATEX1798 U|KEMA 97ATEX1798 U||? r u #i ~ a||||KEMA 97ATEX1798 U|KEMA 97ATEX1798 U||
|**Rated connection**||||||||**Rated connection**||||||
|0.5...6 / 0.5...4||||||||0.5...10 / 0.5...6||||||
|0.5...4 / 0.5...4||||||||0.5...10 / 0.5...6||||||
|0.5...1.0 Nm(M 3)||||||||0.8...1.6 Nm(M 3.5)||||||
|12 / 0.6 x 3.5 mm||||||||12 / 4.0 x 0.8 mm||||||
|||||||||||||||
|1.5...1.5||||||||||||||
|0.5...1.5||||||||||||||
|With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.|With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.|With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.|With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.|||||For AWG 8-7 and AWG 8-19, tightening torque is 1.21.4 Nm|For AWG 8-7 and AWG 8-19, tightening torque is 1.21.4 Nm|For AWG 8-7 and AWG 8-19, tightening torque is 1.21.4 Nm||||
|10 x 40 x 51.5|10 x 40 x 51.5|||||||
|---|---|---|---|---|---|---|---|
|**76 / 16**||||||||
|**1.5...16**||||||||
|IEC 60947-7-1||||Ex e IIT II 2 G D||||
|**IEC**|**UL**|||**CSA**|||**EN 60079-7**|
|800|600|||600|||550|
|57|60|||65|||50|
|10|AWG 14...6||AWG 16...6||||10|
||8 / 3|8 / 3||||||
||B6 / V2|B6 / V2||||||
|? r u #i ~ a||||KEMA 97ATEX1798 U|KEMA 97ATEX1798 U|KEMA 97ATEX1798 U||
|**Rated connection**||||||||
|1.5...10 / 1.5...16||||||||
|1.5...16 / 1.5...10||||||||
|2.0...4.0 Nm(M 4)||||||||
|12 / 1.0 x 5.5 mm||||||||
|||||||||
|||||||||
|||||||||
|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|||When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|||
|**Type**|**Qty.**<br>**Order No.**||**Type**||**Qty.**|**Order No.**||**Type**|**Qty.**|**Order No.**|
|---|---|---|---|---|---|---|---|---|---|---|
|SAK 4|100<br>**1716240000**||SAK 6N||100|**0193260000**||SAK 10|100|**0110060000**|
|SAK 4 BL|100<br>**0128380000**||SAK 6N BL||100|**0193280000**||SAK 10 BL|100|**0110080000**|
||||With AWG 6 and H07V-R10 conductors, an increased MD torque of 1.4|||||A higher torque of 2 to 2.4 Nm is necessary when using H07V-R16 and|A higher torque of 2 to 2.4 Nm is necessary when using H07V-R16 and||
||||to1.6 Nm should be used.|||||AWG 6 conductors.|||
||||||||||||
|**Type**|**current**<br>**Qty.**<br>**Order No.**||**Type**|**current**<br>**Qty.**||**Order No.**||**Type**|**current**<br>**Qty.**|**Order No.**|
|Q 2 SAK4|41 A<br>50<br>**0336700000**||Q 2 SAK6N|32 A|32 A<br>50|**0456700000**||Q 2 SAK10|57 A<br>50|**0457100000**|
|Q 3 SAK4|41 A<br>50<br>**0336800000**||Q 3 SAK6N|57 A|57 A<br>50|**0456800000**||Q 3 SAK10|57 A<br>50|**0457200000**|
|Q 4 SAK4|41 A<br>50<br>**0336900000**||Q 4 SAK6N|57 A|57 A<br>50|**0456900000**||Q 4 SAK10|57 A<br>50|**0457300000**|
|Q 10 SAK4|41 A<br>20<br>**0368800000**||Q 10 SAK6N|32 A|32 A<br>20|**0457000000**||Q 10 SAK10|57 A<br>20|**0457400000**|
||||||||||||
||||||||||||
||||||||||||
||||||||||||
|VL 2 SAK4|32 A<br>50<br>**0197000000**||VL 2 SAK6/10/SAKB|32 A|32 A<br>50|**0135900000**||VL 2 SAK6/10/SAKB|50|**0135900000**|
|VH 19/5/3.5 SAK4-16|50<br>**0285100000**||VH 19/5/3.5 SAK4-16||50|**0285100000**||VH 19/5/3.5 SAK4-16|50|**0285100000**|
|BFSC M3X25|100<br>**0292500000**||BFSC M3X25||100|**0292500000**||BFSC M3X25|100|**0292500000**|
||**Width**|||**Width**|||||**Width**||
|PS 4 F.STB 4|7.6 mm<br>20<br>**0299600000**||PS 4 F.STB 4|7.6 mm<br>20||**0299600000**||PS 4 F.STB 4|7.6 mm<br>20|**0299600000**|
|STB 14/D5/2.3/M3 SAK2.5|50<br>**0168600000**||STB 14/D6/4/M3 SAK10||50|**0169900000**||STB 14/D6/4/M3 SAK10|50|**0169900000**|
||||||||||||
|AP SAK4-10|1.5 mm<br>20<br>**0117960000**||AP SAK4-10|1.5 mm<br>20||**0117960000**||AP SAK4-10|1.5 mm<br>20|**0117960000**|
|AP SAK4-10 BL|1.5 mm<br>20<br>**0117980000**||AP SAK4-10 BL|1.5 mm<br>20||**0117980000**||AP SAK4-10 BL|1.5 mm<br>20|**0117980000**|
|TW 4 SAK4-10|1.5 mm<br>20<br>**0130160000**||TW 4 SAK4-10|1.5 mm<br>20||**0130160000**||TW 4 SAK4-10|1.5 mm<br>20|**0130160000**|
|TW 4 SAK4-10 BL|1.5 mm<br>20<br>**0130180000**||TW 4 SAK4-10 BL|1.5 mm<br>20||**0130180000**||TW 4 SAK4-10 BL|1.5 mm<br>20|**0130180000**|
||||||||||||
|TSCH 1|2 mm<br>100<br>**0319160000**||TSCH 1|2 mm<br>100||**0319160000**||TSCH 1|2 mm<br>100|**0319160000**|
||||||||||||
|AD 4 SAK4|50<br>**0285300000**||AD 4 SAK6N||50|**0196600000**||AD 4 SAK10|50|**0178600000**|
|BFSC M3X22 PA/RT|100<br>**0128900000**||BFSC M3X22 PA/RT||100|**0128900000**||BFSC M3X22 PA/RT|100|**0128900000**|
|DEK 5/6,5|||DEK 5/8 / SCHT 7|||||DEK 5/5|||
||||When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.||||||
**B.3**
**Feed-through terminal**
**SAK 16**
**SAK 35**
**35 mm²**
**B** =
## **TS 32 / PA**
## **16 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [507 x 259] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|12 x 50 x 57.5|18 x 58 x 67.5|
|max. current / max. cond. cross-section|A/mm²|76 / 16|150 / 50|
|Max. clamping range|mm²|2.5...16|2.5...50|
|Technical data|IEC 60947-7-1|Ex e II|T|II 2 G D|IEC 60947-7-1|Ex e II|T|II 2 G D|
|Rated data|IEC|UL|CSA|EN 60079-7|IEC|UL|CSA|EN 60079-7|
|Rated voltage|V|1000|600|600|690|1000|600|600|550|
|Rated current|A|76|80|87|66|125|105|145|109|
|Rated cross-section|mm²|16|AWG 12...4|AWG 14...6|16|35|AWG 12...2|AWG 12...2|35|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|B6 / V2|B8 / V2|
|Approvals|?|r|u|# i ~ a|KEMA 97ATEX1798 U|?|r|u|# ~ a|KEMA 97ATEX1798 U|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|2.5...10 / 4...16|2.5...16 / 4...50|
|flexible / Stranded wire with end ferrules|mm²|4...16 / 4...16|2.5...35 / 2.5...35|
|Tightening torque range (clamping screw)|2.0...4.0 Nm (M 4)|4.0...5.0 Nm (M 6)|
|Stripping length / Blade size|mm/-|15 / 1.0 x 5.5 mm|18 / 6.5 x 1.2 mm|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|mm²|2.5...10 / 10...16|
|flexible / Stranded wire with end ferrules|mm²|2.5...16 / 2.5...16|
|Note|Twin wire end ferrules ZH 2.5 - ZH 16 can be used.|The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-|
|ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Typeypee|Qty.y..|Order No.|
|beigegee|SAK 16|50|0271060000|SAK 35|20|0303560000|
|Blue|SAK 16 BL|50|0271080000|SAK 35 BL|20|0303580000|
|Note|If QIs are aligned side by side, then a TW/AP must be used.|It is possible to use twin ferrules with identical rated voltages (LAB 13090).|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
**==> picture [160 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Typeypee|Qty.y..|Order No.|
|SAK 35|20|0303560000|
|SAK 35 BL|20|0303580000|
|It is possible to use twin ferrules with identical rated voltages (LAB 13090).|
**----- End of picture text -----**<br>
**==> picture [503 x 328] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|beigegee|SAK 16|50|0271060000|SAK 35|20|0303560000|
|Blue|SAK 16 BL|50|0271080000|SAK 35 BL|20|0303580000|
|Note|If QIs are aligned side by side, then a TW/AP must be used.|It is possible to use twin ferrules with identical rated voltages (LAB 13090).|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|Q 2 SAK16|76 A|50|0457500000|QL 2 SAK35|99 A|20|0123600000|
|3-pole|Q 3 SAK16|76 A|50|0457600000|QL 3 SAK35|99 A|20|0123700000|
|4-pole|Q 4 SAK16|76 A|50|0457700000|QL 4 SAK35|99 A|20|0123800000|
|10-pole|Q 10 SAK16|76 A|20|0457800000|QL 10 SAK35|99 A|20|0338600000|
|Connecting sleeve|VH 17/8/5 SAK35|50|0267000000|
|Tit|Mounting screw|—§—§€—_a.|BFSC M4X30|50|0267100000|
|Lock washer|SS M4 D 128-A 4|100|0136400000|
|Switchable link|
|Switchable link|VL 2 SAK16/SAKA|50|0135800000|VL 2 SAK35|119 A|50|0124000000|
|Connecting sleeve|VH 19/5/3.5 SAK4-16|50|0285100000|VH 24.5/8/5 SAK35|50|0298700000|
|Mounting screw|BFSC M3X25|100|0292500000|BFSC M4X35|50|0298900000|
|Testing / Checking|Width|Width|
|Test plug|PS 4 F.STB 4|7.6 mm|20|0299600000|PS 4 F.STB 4|7.6 mm|20|0299600000|
|Socket|STB 14/D6/4/M3 SAK10|50|0169900000|STB 16/D7/4/M4 SAK35|50|0140200000|
|End plate / Partition plate|
|beige|AP SAK16|1.5 mm|20|0271160000|AP SAK35/TW SAK16|1.5 mm|10|0303660000|
|Blue|AP SAK16 BL|1.5 mm|20|0271180000|AP SAK35/TW SAK16 BL|1.5 mm|10|0303680000|
|beige|TW SAK35|1.5 mm|20|0304360000|
|Blue|
|Small partition|
|Small partition|TSCH 1|2 mm|100|0319160000|
|Cover / warning label|
|Cover / warning label|AD 3 SAK16|50|0297800000|AD 3 SAK35|50|0273400000|
|Mounting screw (plastic)|BFSC M3X22 PA/RT|100|0128900000|BFSC M4X32 PA/RT|100|0129100000|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/5|DEK 5/5 / SCHT 7|
|For detailed information on other accessories and ap-|If QIs are aligned side by side, then a TW/AP must be used.|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
## **Accessories**
**B.4**
**Feed-through terminal**
**B**
**SAK 35/IK 35 mm² SAK 35 N**
**Hexagon socket head screw**
**35 mm²**
**SAK 35 N/IK 35 mm²**
## **Hexagon socket head screw**
|18 x 58 x 67.5|18 x 58 x 67.5||||||16 x 58 x 67.5|16 x 58 x 67.5|||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**150 / 50**|||||||**150 / 50**||||||
|**2.5...50**|||||||**2.5...50**||||||
|IEC 60947-7-1||||Ex e IIT II 2 G D|||IEC 60947-7-1||||||
|**IEC**||**UL**||**CSA**||**EN 60079-7**|**IEC**||**UL**||**CSA**||
|1000||600||600||550|1000||600||600||
|125||105||145||109|125||105||120||
|35|AWG 12...2||AWG 12...2|||35|35|AWG 12...2||AWG 12...2|||
|||8 / 3|||||||8 / 3||||
|||B8 / V2|||||||B8 / V2||||
|r #a||||KEMA 97ATEX1798 U||KEMA 97ATEX1798 U|r u #a||||||
|**Rated connection**|||||||**Rated connection**||||||
|2.5...16 / 4...50|||||||2.5...16 / 4...50||||||
|2.5...35 / 2.5...35|||||||2.5...35 / 1.5...35||||||
|4.0...5.0 Nm(M 6)|||||||4.0...5.0 Nm(M 6)||||||
|18 / S4(DIN 6911)|||||||18 / 6.5 x 1.2 mm||||||
||||||||||||||
|2.5...10 / 10...16|||||||2.5...10 / 10...16||||||
|2.5...16 / 2.5...16|||||||2.5...16 / 2.5...16||||||
|The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-|||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||
|ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||||ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.|||ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||||ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||
||||||||||||||
|**Type**||||**Qty.**||**Order No.**|**Type**||||**Qty.**|**Order No.**|
|SAK 35/IK||||20||**0476560000**|SAK 35N||||20|**0550660000**|
||||||||||||||
|It is possible to use twin ferrules with identical rated voltages (LAB 13090).||It is possible to use twin ferrules with identical rated voltages (LAB 13090).|It is possible to use twin ferrules with identical rated voltages (LAB 13090).||||It is possible to use twin ferrules with identical rated voltages (LAB 13090).||It is possible to use twin ferrules with identical rated voltages (LAB 13090).|It is possible to use twin ferrules with identical rated voltages (LAB 13090).|||
|18 x 58 x 67.5|18 x 58 x 67.5||||||16 x 58 x 67.5|16 x 58 x 67.5|||||||16 x 58 x 67.5|16 x 58 x 67.5||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**150 / 50**|||||||**150 / 50**||||||||**150 / 50**|||||
|**2.5...50**|||||||**2.5...50**||||||||**2.5...50**|||||
|IEC 60947-7-1||||Ex e IIT II 2 G D|||IEC 60947-7-1||||||||IEC 60947-7-1|||||
|**IEC**||**UL**||**CSA**||**EN 60079-7**|**IEC**||**UL**||**CSA**||||**IEC**|**UL**|**CSA**|||
|1000||600||600||550|1000||600||600||||1000|600|600|||
|125||105||145||109|125||105||120||||125|105|120|||
|35|AWG 12...2||AWG 12...2|||35|35|AWG 12...2||AWG 12...2|||||35|AWG 12...2|AWG 12...2|||
|||8 / 3|||||||8 / 3|||||||8 / 3||||
|||B8 / V2|||||||B8 / V2|||||||B8 / V2||||
|r #a||||KEMA 97ATEX1798 U|KEMA 97ATEX1798 U|KEMA 97ATEX1798 U|r u #a||||||||r u #a|||||
|**Rated connection**|||||||**Rated connection**||||||||**Rated connection**|||||
|2.5...16 / 4...50|||||||2.5...16 / 4...50||||||||2.5...16 / 4...50|||||
|2.5...35 / 2.5...35|||||||2.5...35 / 1.5...35||||||||2.5...35 / 1.5...35|||||
|4.0...5.0 Nm(M 6)|||||||4.0...5.0 Nm(M 6)||||||||4.0...6.0 Nm(M 6)|||||
|18 / S4(DIN 6911)|||||||18 / 6.5 x 1.2 mm||||||||18 / S4(DIN 6911)|||||
|||||||||||||||||||||
|2.5...10 / 10...16|||||||2.5...10 / 10...16||||||||2.5...10 / 10...16|||||
|2.5...16 / 2.5...16|||||||2.5...16 / 2.5...16||||||||2.5...16 / 2.5...16|||||
|The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-|||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-|||||
|ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||||ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.|ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||||ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||||ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.|||||
|||||||||||||||||||||
|**Type**||||**Qty.**||**Order No.**|**Type**||||**Qty.**||**Order No.**||**Type**||**Qty.**||**Order No.**|
|SAK 35/IK||||20||**0476560000**|SAK 35N||||20||**0550660000**||SAK 35N/IK||20||**0555760000**|
|||||||||||||||||||||
|It is possible to use twin ferrules with identical rated voltages (LAB 13090).||It is possible to use twin ferrules with identical rated voltages (LAB 13090).|It is possible to use twin ferrules with identical rated voltages (LAB 13090).||||It is possible to use twin ferrules with identical rated voltages (LAB 13090).||It is possible to use twin ferrules with identical rated voltages (LAB 13090).|It is possible to use twin ferrules with identical rated voltages (LAB 13090).|||||It is possible to use twin ferrules with identical rated voltages (LAB 13090).||It is possible to use twin ferrules with identical rated voltages (LAB 13090).|||
|||||||||||||||||||||
|**Type**||**current**<br>**Qty.**||||**Order No.**|**Type**||**current**<br>**Qty.**||||**Order No.**||**Type**|**current**<br>**Qty.**|||**Order No.**|
|QL 2 SAK35|||99 A<br>20|||**0123600000**|QL 2 SAK35N|||99 A<br>50|||**0564900000**||QL 2 SAK35N||99 A<br>50||**0564900000**|
|QL 3 SAK35|||99 A<br>20|||**0123700000**|QL 3 SAK35N|||99 A<br>50|||**0565000000**||QL 3 SAK35N||99 A<br>50||**0565000000**|
|QL 4 SAK35|||99 A<br>20|||**0123800000**|QL 4 SAK35N|||99 A<br>50|||**0565100000**||QL 4 SAK35N||99 A<br>50||**0565100000**|
|QL 10 SAK35|||99 A<br>20|||**0338600000**|QL 10 SAK35N|||99 A<br>20|||**0565200000**||QL 10 SAK35N||99 A<br>20||**0565200000**|
|VH 17/8/5 SAK35||||50||**0267000000**|VH 17/8/5 SAK35||||50||**0267000000**||VH 17/8/5 SAK35||50||**0267000000**|
|BFSC M4X30||||50||**0267100000**|BFSC M4X30||||50||**0267100000**||BFSC M4X30||50||**0267100000**|
|SS M4 D 128-A 4|SS M4 D 128-A 4|||100||**0136400000**|SS M4 D 128-A 4|SS M4 D 128-A 4|||100||**0136400000**||SS M4 D 128-A 4|SS M4 D 128-A 4|100||**0136400000**|
|||||||||||||||||||||
|VL 2 SAK35||119 A<br>50||||**0124000000**||||||||||||||
|VH 24.5/8/5 SAK35||||50||**0298700000**||||||||||||||
|BFSC M4X35||||50||**0298900000**||||||||||||||
|||**Width**|||||||**Width**|||||||**Width**||||
|PS 4 F.STB 4||7.6 mm<br>20||||**0299600000**|PS 4 F.STB 4||7.6 mm<br>20||||**0299600000**||PS 4 F.STB 4|7.6 mm<br>20|||**0299600000**|
|STB 16/D7/4/M4 SAK35||||50||**0140200000**|STB 16/D7/4/M4 SAK35||||50||**0140200000**||STB 16/D7/4/M4 SAK35||50||**0140200000**|
|||||||||||||||||||||
|AP SAK35/TW SAK16|AP SAK35/TW SAK16<br>1.5 mm<br>10|||||**0303660000**|AP SAK35/TW SAK16|AP SAK35/TW SAK16<br>1.5 mm<br>10|||||**0303660000**||AP SAK35/TW SAK16|AP SAK35/TW SAK16<br>1.5 mm<br>10|||**0303660000**|
||||||||AP SAK35/TW SAK16 BL|AP SAK35/TW SAK16 BL<br>1.5 mm<br>10|||||**0303680000**|||||||
|TW SAK35||1.5 mm<br>20||||**0304360000**|TW SAK35||1.5 mm<br>20||||**0304360000**||TW SAK35|1.5 mm<br>20|||**0304360000**|
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|||||||||||||||||||||
|AD 4 SAK35||||50||**0178700000**|AD 4 SAK35N||||50||**0576700000**||AD 4 SAK35N||50||**0576700000**|
|BFSC M4X32 PA/RT||||100||**0129100000**|BFSC M4X32 PA/RT||||100||**0129100000**||BFSC M4X32 PA/RT||100||**0129100000**|
|DEK 5/5|||||||DEK 5/5||||||||DEK 5/5|||||
|If QIs are aligned side by side, then a TW/AP must be used.|||||||If QIs are aligned side by side, then a TW/AP must be used.||||||||If QIs are aligned side by side, then a TW/AP must be used.|||||
**B.5**
**Feed-through terminal**
**SAK 2.5**
**SAK 4**
**2.5 mm²**
**4 mm²**
**B** __
## **TS 32 / KrG**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [507 x 563] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|6 x 36.5 x 46.5|6.5 x 40 x 51.5|
|max. current / max. cond. cross-section|A/mm²|32 / 6|41 / 6|
|Max. clamping range|mm²|0.13...6|0.13...6|
|Technical data|IEC 60947-7-1|Ex e II|T|II 2 G D|IEC 60947-7-1|Ex e II|T|II 2 G D|
|Rated data|IEC|UL|CSA|EN 60079-7|IEC|UL|CSA|EN 60079-7|
|Rated voltage|V|800|600|600|550|800|600|600|550|
|Rated current|A|24|20|25|21|32|20|36|28|
|Rated cross-section|mm²|2.5|AWG 22...12|AWG 26...10|2.5|4|AWG 22...12|AWG 26...10|4|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / 5VA|A4 / 5VA|
|Approvals|?|r|u|# i ~ a|KEMA 97ATEX1798 U|?|r|u|# i ~ a|KEMA 97ATEX1798 U|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...6 / 0.5...4|0.5...6 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...2.5|0.5...4 / 0.5...4|
|Tightening torque range (clamping screw)|0.4...0.6 Nm (M 2.5)|0.5...1.0 Nm (M 3)|
|Stripping length / Blade size|mm/-|10 / 0.6 x 3.5 mm|12 / 0.6 x 3.5 mm|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|mm²|...1.5|0.5...1.5|
|flexible / Stranded wire with end ferrules|mm²|0.5...1.5|0.5...1 / 0.5...1|
|Note|With twin ferrules ZH 0.5 to ZH 1.5, rated voltage is 690 V.|With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Medium yellow|SAK 2.5 KRG|100|0279620000|SAK 4 KRG|100|0128320000|
|Blue|SAK 2.5 KRG/BL|100|0279670000|SAK 4 KRG BL|100|0128370000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|Q 2 SAK2.5|41 A|50|0337000000|Q 2 SAK4|41 A|50|0336700000|
|3-pole|Q 3 SAK2.5|41 A|50|0337100000|Q 3 SAK4|41 A|50|0336800000|
|4-pole|Q 4 SAK2.5|41 A|50|0337200000|Q 4 SAK4|41 A|50|0336900000|
|10-pole|Q 10 SAK2.5|41 A|20|0368700000|Q 10 SAK4|41 A|20|0368800000|
|Connecting sleeve|
|Mounting screw|
|Lock washer|
|Switchable link|
|Switchable link|VL 2 SAK4|32 A|50|0197000000|
|Connecting sleeve|VH 19/5/3.5 SAK4-16|50|0285100000|
|Mounting screw|BFSC M3X25|100|0292500000|
|Testing / Checking|Width|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 6/D3.9/2.3/M2.5 ZB|50|0130200000|STB 14/D5/2.3/M3 SAK2.5|50|0168600000|
|End plate / Partition plate|
|Medium yellow|AP SAK2.5 KRG|1.5 mm|20|0279520000|AP SAK4-10 KRG|1.5 mm|20|0117920000|
|Blue|AP SAK2.5 KRG BL|1.5 mm|20|0279570000|AP SAK4-10 KRG/BL|1.5 mm|20|0117970000|
|Medium yellow|TW SAK2.5 KRG|2.5 mm|20|0302820000|TW SAK4-10 KRG|2.5 mm|20|0130120000|
|Blue|TW SAK2.5 KRG/BL|2.5 mm|20|0302870000|TW SAK4-10 KRG/BL|2.5 mm|20|0130170000|
|Small partition|
|Small partition|TSCH 1|2 mm|100|0319160000|TSCH 1|2 mm|100|0319160000|
|Cover / warning label|
|Cover / warning label|AD 4 AKZ4|50|0303400000|AD 4 SAK4|50|0285300000|
|Mounting screw (plastic)|BFSC M3X22 PA/RT|100|0128900000|BFSC M3X22 PA/RT|100|0128900000|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/6 / SCHT 7|DEK 5/6,5 / SCHT 7|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
## **Accessories**
**B.6**
**Feed-through terminal**
**SAK 6 N**
**6 mm² SAK 10**
**10 mm² SAK 16**
**B**
**16 mm²**
|8 x 40 x 51.5|||||||10 x 40 x 51.5|10 x 40 x 51.5|||||||12 x 50 x 57.5|12 x 50 x 57.5||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**57 / 10**<br>**0.33...10**|~~o_o~~||||||**76 / 16**<br>**1.5...16**|~~o——_4__o~~|||||||**76 / 16**<br>**2.5...16**|||~~o——}___o~~|~~o——}___o~~|~~o——}___o~~|~~o——}___o~~|
|IEC 60947-7-1|||Ex e IIT II 2 G D||||IEC 60947-7-1|||Ex e IIT II 2 G D|||||IEC 60947-7-1||||Ex e IIT II 2 G D|||
|**IEC**|**UL**||**CSA**|||**EN 60079-7**|**IEC**|**UL**||**CSA**|||**EN 60079-7**||**IEC**||**UL**||**CSA**||**EN 60079-7**|
|800|600||600|||550|800|600||600|||550||1000|600|||600||690|
|41|40||47|||36|57|60||65|||50||76||80||87||66|
|6|AWG 22...8|AWG 20...8||||6|10|AWG 14...6|AWG 16...6||||10||16|AWG 12...4|||AWG 14...6||16|
||8 / 3|||||||8 / 3|||||||||8 / 3|||||
||A5 / 5VA|A5 / 5VA||||||B6 / 5VA|B6 / 5VA||||||||B6 / 5VA||B6 / 5VA|||
|? r u #i ~ a|||KEMA 97ATEX1798 U|KEMA 97ATEX1798 U|KEMA 97ATEX1798 U||? r u #i ~ a|||KEMA 97ATEX1798 U||KEMA 97ATEX1798 U|||? r u #i ~ a||||KEMA 97ATEX1798 U||KEMA 97ATEX1798 U|
|**Rated connection**|||||||**Rated connection**||||||||**Rated connection**|||||||
|0.5...10 / 0.5...6|||||||1.5...10 / 1.5...16||||||||2.5...10 / 4...16|||||||
|0.5...10 / 0.5...6|||||||1.5...16 / 1.5...10||||||||4...16 / 4...16|||||||
|0.8...1.6 Nm(M 3.5)|||||||2.0...4.0 Nm(M 4)||||||||2.0...4.0 Nm(M 4)|||||||
|12 / 4.0 x 0.8 mm|||||||12 / 1.0 x 5.5 mm||||||||15 / 1.0 x 5.5 mm|||||||
|||||||||||||||||||||||
|||||||||||||||||||||||
|||||||||||||||||||||||
|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.||When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|||When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.||When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|||||Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||Twin wire end ferrules ZH 2.5 - ZH 16 can be used.|Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||||
|||||||||||||||||||||||
|**Type**|||**Qty.**|||**Order No.**|**Type**|||**Qty.**|||**Order No.**||**Type**||||**Qty.**||**Order No.**|
|SAK 6N KRG|||100|||**0193220000**|SAK 10 KRG|||100|||**0110020000**||SAK 16 KRG||||50||**0271020000**|
||||||||SAK 10 KRG/BL|||100|||**0110070000**|||||||||
|With AWG 6 and H07V-R10 conductors, an increased MD torque of 1.4||||With AWG 6 and H07V-R10 conductors, an increased MD torque of 1.4|With AWG 6 and H07V-R10 conductors, an increased MD torque of 1.4||A higher torque of 2 to 2.4 Nm is necessary when using H07V-R16 and|A higher torque of 2 to 2.4 Nm is necessary when using H07V-R16 and|||||||If QIs are aligned side by side, then a TW/AP must be used.|||||||
|to1.6 Nm should be used.|to1.6 Nm should be used.||||||AWG 6 conductors.|||||||||||||||
|||||||||||||||||||||||
|**Type**|**current**<br>**Qty.**|||||**Order No.**|**Type**|**current**<br>**Qty.**|||||**Order No.**||**Type**||**current**<br>**Qty.**||||**Order No.**|
|Q 2 SAK6N||32 A|32 A<br>50|||**0456700000**|Q 2 SAK10||57 A|57 A<br>50|||**0457100000**||Q 2 SAK16||||76 A<br>50||**0457500000**|
|Q 3 SAK6N||57 A|57 A<br>50|||**0456800000**|Q 3 SAK10||57 A|57 A<br>50|||**0457200000**||Q 3 SAK16||||76 A<br>50||**0457600000**|
|Q 4 SAK6N||57 A|57 A<br>50|||**0456900000**|Q 4 SAK10||57 A|57 A<br>50|||**0457300000**||Q 4 SAK16||||76 A<br>50||**0457700000**|
|Q 10 SAK6N||32 A|32 A<br>20|||**0457000000**|Q 10 SAK10||57 A|57 A<br>20|||**0457400000**||Q 10 SAK16||||76 A<br>20||**0457800000**|
|||||||||||||||||||||||
|||||||||||||||||||||||
|||||||||||||||||||||||
|||||||||||||||||||||||
|VL 2 SAK6N/SAKT||32 A|32 A<br>50|||**0194700000**|VL 2 SAK6/10/SAKB||32 A|32 A<br>50|||**0135900000**||VL 2 SAK16/SAKA||||57 A<br>50||**0135800000**|
|VH 19/5/3.5 SAK4-16|||50|||**0285100000**|VH 19/5/3.5 SAK4-16|||50|||**0285100000**||VH 19/5/3.5 SAK4-16||||50||**0285100000**|
|BFSC M3X25|||100|||**0292500000**|BFSC M3X25|||100|||**0292500000**||BFSC M3X25||||100||**0292500000**|
||**Width**|||||||**Width**||||||||||**Width**||||
|PS 4 F.STB 4|7.6 mm<br>20|||||**0299600000**|PS 4 F.STB 4|7.6 mm<br>20|||||**0299600000**||PS 4 F.STB 4|||7.6 mm<br>20|||**0299600000**|
||||||||STB 14/D6/4/M3 SAK10|||50|||**0169900000**||STB 14/D6/4/M3 SAK10||||50||**0169900000**|
|||||||||||||||||||||||
|AP SAK4-10 KRG<br>1.5 mm<br>20||||||**0117920000**|AP SAK4-10 KRG<br>1.5 mm<br>20||||||**0117920000**||AP SAK16 KRG||||3 mm<br>20||**0271120000**|
|AP SAK4-10 KRG/BL<br>1.5 mm<br>20||||||**0117970000**|AP SAK4-10 KRG/BL<br>1.5 mm<br>20||||||**0117970000**||AP SAK35/TW SAK16 BL|AP SAK35/TW SAK16 BL||1.5 mm<br>10|||**0303680000**|
|TW SAK4-10 KRG<br>2.5 mm<br>20||||||**0130120000**|TW SAK4-10 KRG<br>2.5 mm<br>20||||||**0130120000**||TW SAK16 KRG||||3 mm<br>20||**0281120000**|
|TW SAK4-10 KRG/BL<br>2.5 mm<br>20||||||**0130170000**|TW SAK4-10 KRG/BL<br>2.5 mm<br>20||||||**0130170000**|||||||||
|||||||||||||||||||||||
|TSCH 1||2 mm<br>100||||**0319160000**|TSCH 1||2 mm<br>100||||**0319160000**||TSCH 1||||2 mm<br>100||**0319160000**|
|||||||||||||||||||||||
|AD 4 SAK6N|||50|||**0196600000**|AD 4 SAK10|||50|||**0178600000**||AD 4 SAK16||||50||**0518200000**|
|BFSC M3X22 PA/RT|||100|||**0128900000**|BFSC M3X22 PA/RT|||100|||**0128900000**||BFSC M3X22 PA/RT||||100||**0128900000**|
|DEK 5/8 / SCHT 7|DEK 5/8 / SCHT 7||||||DEK 5/5||||||||DEK 5/5|||||||
|12 x 50 x 57.5|12 x 50 x 57.5|||||||
|---|---|---|---|---|---|---|---|
|**76 / 16**<br>**2.5...16**|||~~o——}___o~~|||||
|IEC 60947-7-1||||Ex e IIT II 2 G D|||II 2 G D|
|**IEC**||**UL**||**CSA**||**EN 60079-7**||
|1000|600|||600||690||
|76||80||87||66||
|16|AWG 12...4|||AWG 14...6||16||
|||8 / 3||8 / 3||||
|||B6 / 5VA|B6 / 5VA|B6 / 5VA||||
|? r u #i ~ a||||KEMA 97ATEX1798 U||KEMA 97ATEX1798 U|KEMA 97ATEX1798 U|
|**Rated connection**||||||||
|2.5...10 / 4...16||||||||
|4...16 / 4...16||||||||
|2.0...4.0 Nm(M 4)||||||||
|15 / 1.0 x 5.5 mm||||||||
|||||||||
|||||||||
|||||||||
|Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||Twin wire end ferrules ZH 2.5 - ZH 16 can be used.|Twin wire end ferrules ZH 2.5 - ZH 16 can be used.|||||
**B.7**
**Feed-through terminal**
**SAK 35**
**SAK 35/IK**
**35 mm²**
**B**
## **TS 32 / KrG**
## **35 mm²**
## **Hexagon socket head screw**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [507 x 194] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|18 x 58 x 67.5|18 x 58 x 67.5|
|max. current / max. cond. cross-section|A/mm²|125 / 50|125 / 50|
|o_o|o——_t___»|
|Max. clamping range|mm²|6...50|6...50|
|Technical data|IEC 60947-7-1|Ex e II|T|II 2 G D|IEC 60947-7-1|Ex e II|T|II 2 G D|
|Rated data|IEC|UL|CSA|EN 60079-7|IEC|UL|CSA|EN 60079-7|
|Rated voltage|V|1000|600|600|550|1000|600|600|550|
|Rated current|A|125|105|145|109|125|105|145|109|
|Rated cross-section|mm²|35|AWG 6...2|AWG 6...2|35|35|AWG 6...2|AWG 6...2|35|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|B9 / 5VA|B9 / 5VA|
|Approvals|?|r|u|# i ~ a|KEMA 97ATEX1798 U|r|# a|KEMA 97ATEX1798 U|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|6...16 / 16...50|6...16 / 16...50|
|flexible / Stranded wire with end ferrules|mm²|10...35 / 10...35|10...35 / 10...35|
|Tightening torque range (clamping screw)|5,0 Nm (M 6)|5,0 Nm (M 6)|
|Stripping length / Blade size|mm/-|20 / 6.5 x 1.2 mm|20 / S4 (DIN 6911)|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Note|The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-|The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-|
**----- End of picture text -----**<br>
## **Technical data**
The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stranded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.
The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stranded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.
## **Ordering data**
**==> picture [508 x 338] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Medium yellow|SAK 35 KRG|20|0303520000|SAK 35/IK KRG|20|0476520000|
|Blue|
|Note|It is possible to use twin ferrules with identical rated voltages (LAB 13090).|It is possible to use twin ferrules with identical rated voltages (LAB 13090).|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAK35|99 A|20|0123600000|QL 2 SAK35|99 A|20|0123600000|
|3-pole|QL 3 SAK35|99 A|20|0123700000|QL 3 SAK35|99 A|20|0123700000|
|4-pole|QL 4 SAK35|99 A|20|0123800000|QL 4 SAK35|99 A|20|0123800000|
|10-pole|QL 10 SAK35|99 A|20|0338600000|QL 10 SAK35|99 A|20|0338600000|
|Connecting sleeve|VH 17/8/5 SAK35|50|0267000000|VH 17/8/5 SAK35|50|0267000000|
|Mounting screw|BFSC M4X30|50|0267100000|BFSC M4X30|50|0267100000|
|Lock washer|SS M4 D 128-A 4|100|0136400000|SS M4 D 128-A 4|100|0136400000|
|Switchable link|
|Switchable link|VL 2 SAK35|119 A|50|0124000000|VL 2 SAK35|119 A|50|0124000000|
|Connecting sleeve|VH 24.5/8/5 SAK35|50|0298700000|VH 24.5/8/5 SAK35|50|0298700000|
|Mounting screw|BFSC M4X35|50|0298900000|BFSC M4X35|50|0298900000|
|Testing / Checking|Width|Width|
|Test plug|PS 4 F.STB 4|7.6 mm|20|0299600000|PS 4 F.STB 4|7.6 mm|20|0299600000|
|Socket|STB 16/D7/4/M4 SAK35|50|0140200000|STB 16/D7/4/M4 SAK35|50|0140200000|
|End plate / Partition plate|
|Medium yellow|AP SAK35 KRG|3 mm|10|0303620000|AP SAK35 KRG|3 mm|10|0303620000|
|Blue|AP SAK35 KRG/BL|3 mm|10|0303670000|
|Medium yellow|TW SAK35 KRG|3 mm|20|0304320000|TW SAK35 KRG|3 mm|20|0304320000|
|Blue|
|Small partition|
|Small partition|
|Cover / warning label|
|Cover / warning label|AD 4 SAK35|50|0178700000|AD 4 SAK35|50|0178700000|
|Mounting screw (plastic)|BFSC M4X32 PA/RT|100|0129100000|BFSC M4X32 PA/RT|100|0129100000|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/5 / SCHT 7|DEK 5/5|
|For detailed information on other accessories and ap-|If QIs are aligned side by side, then a TW/AP must be used.|If QIs are aligned side by side, then a TW/AP must be used.|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
## **Accessories**
**B.8**
**Feed-through terminal**
**SAK 35 N**
**SAK 70**
**SAK 95**
**B**
## **35 mm²**
## **70 mm²**
**95 mm²**
16 x 58 x 67.5 **125 / 50 2.5...50**
22 x 75 x 79.5 **192 / 70 16...70**
28 x 87.9 x 100.5 **232 / 120 16...120**
|IEC 60947-7-1|IEC 60947-7-1||||IEC 60947-7-1|IEC 60947-7-1|||
|---|---|---|---|---|---|---|---|---|
|**IEC**||**UL**||**CSA**|**IEC**|**UL**||**CSA**|
|1000||600||600|1000|600||600|
|125||105||120|192|150||150|
|35|AWG 12...2||AWG 12...2||70|AWG 4...2/0||AWG 4...2/0|
|||8 / 3|||||8 / 3||
|||B8 / 5VA|B8 / 5VA||||B11 / 5VA||
|r u #a|||||r u #~ a||||
|**Rated connection**|||||**Rated connection**||||
|2.5...16 / 4...50|||||16...16 / 16...70||||
|2.5...35 / 1.5...35|||||16...70 / 16...35||||
|4.0...5.0 Nm(M 6)|||||6.0...12 Nm(M 8)||||
|18 / 6.5 x 1.2 mm|||||24 / S6(DIN 6911)||||
||||||||||
||||||||||
||||||||||
|The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-<br>Connection torque H07V-R70 = 12 Nm|||Connection torque H07V-R70 = 12 Nm||
|ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||||ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.|||||
||||||||||
|**Type**||||**Qty.**|**Order No.**<br>**Type**|||**Qty.**<br>**Order No.**|
|SAK 35N KRG||||20|**0550620000**<br>SAK 70 KRG|||10<br>**0340820000**|
||||||SAK 70 KRG/BL|||10<br>**0340870000**|
|IEC 60947-7-1|IEC 60947-7-1|||IEC 60947-7-1|IEC 60947-7-1|||||IEC 60947-7-1|IEC 60947-7-1|||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**IEC**||**UL**||**CSA**<br>**IEC**|**UL**||**CSA**|||**IEC**|**UL**||**CSA**|||
|1000||600||600<br>1000|600||600|||1000|600||600|||
|125||105||120<br>192|150||150|||232|190||200|||
|35|AWG 12...2||AWG 12...2<br>70||AWG 4...2/0||AWG 4...2/0|||95|AWG 6...4/0||AWG 6...4/0|||
|||8 / 3||||8 / 3||||||8 / 3|8 / 3|||
|||B8 / 5VA|B8 / 5VA|||B11 / 5VA||||||B13 / 5VA|B13 / 5VA|||
|r u #a||||r u #~ a||||||ra||||||
|**Rated connection**||||**Rated connection**||||||**Rated connection**||||||
|2.5...16 / 4...50||||16...16 / 16...70||||||16...16 / 16...120||||||
|2.5...35 / 1.5...35||||16...70 / 16...35||||||16...95 / 10...95||||||
|4.0...5.0 Nm(M 6)||||6.0...12 Nm(M 8)||||||16...20 Nm(M 10|M 10)|||||
|18 / 6.5 x 1.2 mm||||24 / S6(DIN 6911)||||||30 / S8(DIN 6911)||||||
|||||||||||||||||
|||||||||||||||||
|||||||||||||||||
|The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-<br>Connection torque H07V-R70 = 12 Nm||Connection torque H07V-R70 = 12 Nm||||Ribbon cable (segmented ribbon) can be connected ranging from 3 to 6 segments|||Ribbon cable (segmented ribbon) can be connected ranging from 3 to 6 segments||Ribbon cable (segmented ribbon) can be connected ranging from 3 to 6 segments|
|ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||||ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||||||of 0.8x9 mm, up to 6 segments of 0.8x16 mm and up to 6 segments of 0.5x13 mm.||of 0.8x9 mm, up to 6 segments of 0.8x16 mm and up to 6 segments of 0.5x13 mm.||of 0.8x9 mm, up to 6 segments of 0.8x16 mm and up to 6 segments of 0.5x13 mm.||
|||||||||||||||||
|**Type**||||**Qty.**<br>**Order No.**<br>**Type**|||**Qty.**|**Order No.**||**Type**|||**Qty.**||**Order No.**|
|SAK 35N KRG||||20<br>**0550620000**<br>SAK 70 KRG|||10|**0340820000**||SAK 95 KRG|||10||**0550520000**|
|||||SAK 70 KRG/BL|||10|**0340870000**||||||||
|It is possible to use twin ferrules with identical rated voltages (LAB 13090).||It is possible to use twin ferrules with identical rated voltages (LAB 13090).|It is possible to use twin ferrules with identical rated voltages (LAB 13090).|||||||||||||
|||||||||||||||||
|**Type**||**current**<br>**Qty.**<br>**Order No.**<br>**Type**||||**current**<br>**Qty.**||**Order No.**||**Type**||**current**<br>**Qty.**|||**Order No.**|
|QL 2 SAK35N|||99 A<br>50<br>**0564900000**<br>QL 2 SAK70|||192 A<br>20||**0345300000**||QL 2 SAKG28|||10||**0551200000**|
|QL 3 SAK35N|||99 A<br>50<br>**0565000000**<br>QL 3 SAK70|||192 A<br>5||**0167000000**||QL 3 SAKG28||||5|**0407600000**|
|QL 4 SAK35N|||99 A<br>50<br>**0565100000**|||||||QL 4 SAKG28||||5|**0407700000**|
|QL 10 SAK35N|||99 A<br>20<br>**0565200000**|||||||||||||
|VH 17/8/5 SAK35||||50<br>**0267000000**<br>VH 30.5/11/5.5 SAK70|||20|**0345500000**||VH 35/11/5.5 SAK95|||10||**0551100000**|
|BFSC M4X30||||50<br>**0267100000**<br>BFSC M5X45|||20|**0345600000**||KISC M5X50/26 SAK95|||20||**0630200000**|
|SS M4 D 128-A 4|SS M4 D 128-A 4|||100<br>**0136400000**<br>SS M5 D 128-A 5|SS M5 D 128-A 5||50|**0346100000**||||||||
|||||||||||||||||
|||||||||||||||||
|||||||||||||||||
|||||||||||||||||
|||**Width**||||**Width**|||||||**Width**|||
|PS 4 F.STB 4||7.6 mm<br>20<br>**0299600000**<br>PS 4 F.STB 4||||7.6 mm<br>20||**0299600000**||PS 4 F.STB 4||7.6 mm<br>20|||**0299600000**|
|STB 16/D7/4/M4 SAK35||||50<br>**0140200000**<br>STB 16/D7/4/M5 SAK70|||50|**0385400000**||STB 16/D7/4/M5 SAK70|||50||**0385400000**|
|||||||||||||||||
|AP SAK35 KRG|||3 mm<br>10<br>**0303620000**<br>AP 70 SAK70 KRG||||4 mm<br>10|**0340920000**||AP SAK95 KRG|||3 mm<br>10||**0550920000**|
|AP SAK35 KRG/BL|||3 mm<br>10<br>**0303670000**|||||||||||||
|TW SAK35 KRG|||3 mm<br>20<br>**0304320000**|||||||||||||
|||||||||||||||||
|||||||||||||||||
|||||||||||||||||
|||||||||||||||||
|AD 4 SAK35N||||50<br>**0576700000**<br>AD 3 SAK70|||10|**0344300000**||||||||
|BFSC M4X32 PA/RT||||100<br>**0129100000**<br>BFSC M5X45 PA/NA|||50|**0344400000**||BFSC M5X45 PA/NA|||50||**0344400000**|
|DEK 5/5||||DEK 5/5||||||DEK 5/5||||||
|If QIs are aligned side by side, then a TW/AP must be used.||||||||||||||||
**B.9**
**Two-tier modular terminals**
**DK 4 Q**
**DK 4**
**4 mm²**
**B** _
## **TS 32 / PA**
## **4 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [507 x 249] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|6 x 50 x 59.5|6 x 50 x 59.5|
|max. current / max. cond. cross-section|A/mm²|41 / 6|41 / 6|
|Max. clamping range|mm²|0.13...6|0.13...6|
|Technical data|IEC 60947-7-1|Ex e II|T|II 2 G D|IEC 60947-7-1|Ex e II|T|II 2 G D|
|Rated data|IEC|UL|CSA|EN 60079-7|IEC|UL|CSA|EN 60079-7|
|Rated voltage|V|500|300|300|275|500|300|300|275|
|Rated current|A|32|27|10|28|32|27|10|28|
|Rated cross-section|mm²|4|AWG 22...12|AWG 26...10|4|4|AWG 22...12|AWG 26...10|4|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|6 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|A3 / V2|
|Approvals|r|u|# ~ a|SIRA 02ATEX3316U|r|# a|SIRA 02ATEX3316U|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...6 / 0.5...4|0.5...6 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...2.5|0.5...4 / 0.5...2.5|
|Tightening torque range (clamping screw)|0.5...0.8 Nm (M 3)|0.5...0.8 Nm (M 3)|
|Stripping length / Blade size|mm/-|9 / 0.6 x 3.5 mm|9 / 0.6 x 3.5 mm|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|mm²|0.5...1.5|0.5...1.5|
|flexible / Stranded wire with end ferrules|mm²|0.5...1.5 / 0.5...1.5|0.5...1.5 / 0.5...1.5|
|Note|With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.|With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.|
|Ordering datag data data|
|Version|Typeypee|Qty.y..|Order No.|Typeypee|Qty.y..|Order No.|
|beigegee|DK 4|100|0355460000|DK 4Q/32|100|0590060000|
|Blue|DK 4 BL|100|0355480000|DK 4Q/32 BL|100|0590080000|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
**==> picture [509 x 220] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Version|Typeypee|Qty.y..|Order No.|Typeypee|Qty.y..|Order No.|
|beigegee|DK 4|100|0355460000|DK 4Q/32|100|0590060000|
|Blue|DK 4 BL|100|0355480000|DK 4Q/32 BL|100|0590080000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|Q 2 AKZ4|32 A|50|0336400000|Q 2 AKZ4|32 A|50|0336400000|
|3-pole|Q 3 AKZ4|32 A|50|0336500000|Q 3 AKZ4|32 A|50|0336500000|
|4-pole|Q 4 AKZ4|32 A|50|0336600000|Q 4 AKZ4|32 A|50|0336600000|
|rtf|10-pole|—§——_|Q 10 AKZ4|32 A|20|0368600000|a|———_|Q 10 AKZ4|32 A|20|0368600000|ae|
|Testing / Checking|Width|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|End plate / Partition plate|
|beige|AP DK4|1.5 mm|20|0359260000|AP DK4Q|1.5 mm|20|1397160000|
|Blue|AP DK4 BL|1.5 mm|20|0359280000|AP DK4Q BL|1.5 mm|20|1397180000|
|Dark beige Wemid|WTW EN|3 mm|20|1058800000|WTW EN|3 mm|20|1058800000|
|Small partition|
|Small partition|TSCH 6 DKI S4|5 mm|100|0190260000|TSCH 6 DKI S4|5 mm|100|0190260000|
|Cover / warning label|
|Cover / warning label|
|Mounting screw (plastic)|
**----- End of picture text -----**<br>
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/6
DEK 5/6
**B.10**
**Two-tier modular terminals**
**DK 4 QV**
**B**
## **4 mm²**
|6 x 54 x 59.5|6 x 54 x 59.5|||||||
|---|---|---|---|---|---|---|---|
|**41 / 6**||||||||
|**0.13...6**||||||||
|IEC 60947-7-1||||Ex e IIT II 2 G D||||
|**IEC**||**UL**||**CSA**||**EN 60079-7**||
|500||300||300||275||
|32||27||10||28||
|4|AWG 22...12||AWG 26...12|||4||
|||6 / 3||||||
|||A3 / V2||||||
|r #a|||||SIRA 02ATEX3316U|SIRA 02ATEX3316U||
|**Rated connection**||||||||
|0.5...6 / 0.5...4||||||||
|0.5...4 / 0.5...2.5||||||||
|0.5...0.8 Nm(M 3)||||||||
|8 / 0.6 x 3.5 mm||||||||
|||||||||
|0.5...1.5||||||||
|0.5...1.5 / 0.5...1.5||||||||
With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.
|**Type**|**Qty.**|**Order No.**|
|---|---|---|
|DK 4QV/32|100|**0590260000**|
|DK 4QV/32 BL|100|**0590280000**|
|**Type**|**current**<br>**Qty.**<br>**Order No.**|
|---|---|
|Q 2 AKZ4|32 A<br>50<br>**0336400000**|
|Q 3 AKZ4|32 A<br>50<br>**0336500000**|
|Q 4 AKZ4|32 A<br>50<br>**0336600000**|
|Q 10 AKZ4|32 A<br>20<br>**0368600000**|
||**Width**|
|PS 2.3 RT|5.4 mm<br>20<br>**0180400000**|
|STB 8.5/D4/2.3/M2.5 AKZ|50<br>**0215700000**|
|||
|AP DK4Q|1.5 mm<br>20<br>**1397160000**|
|AP DK4Q BL|1.5 mm<br>20<br>**1397180000**|
|WTW EN|3 mm<br>20<br>**1058800000**|
|||
|TSCH 6 DKI S4|5 mm<br>100<br>**0190260000**|
|||
|AD 4 AKZ4|50<br>**0303400000**|
|BFSC M2.5X18 PA/RT|100<br>**0303300000**|
DEK 5/6
**B.11**
**Modular PE terminals**
**EK 2.5N**
**EK 4**
**4 mm²**
**B**
## **TS 32 / PA**
## **2.5 mm²**
|In hazardous area applications, the installation instructions|In hazardous area applications, the installation instructions||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|and the rated data specifications for accessories given in the|||||||||||||
|technical appendix must be followed.|||||||||||||
|Width/Length/height with TS32x7.5|mm<br>6 x 36.5 x 46.5|||||||8 x 40 x 51.5|||||
|**Technical data**<br>max. current / max. cond. cross-section<br>Max. clamping range|A/mm²<br>mm²<br>**/ 4**<br>**0.33...4**<br>IEC 60947-7-2|||PE<br>Ex e IIT II 2 G D||||**/ 6**<br>**0.33...6**<br>IEC 60947-7-2|||PE<br>Ex e IIT II 2 G D||
|**Rated data**|**IEC**|**UL**|**CSA**|||**EN 60079-7**||**IEC**|**UL**|**CSA**||**EN 60079-7**|
|Rated cross-section|mm²<br>2.5|AWG 22...12|AWG 26...10|AWG 26...10||AWG 26...10||4|AWG 22...12|AWG 26...10|AWG 26...10<br>AWG 26...10||
|Rated voltage to adjacent terminal|V<br>800|||||||800|||||
|Rated impulse withstand voltage to adjacent terminal<br>kV<br>8||||||||8|||||
|Short-time withstand current|300 A(2.5 mm²)|||||||480 A(4 mm²|4 mm²)||||
|Pollution severity||3|||||||3||||
|Gauge to IEC 60947-1 / UL94 Flammabilityclass||A3 / V2|A3 / V2||||||A4 / V2|A4 / V2|||
|Approvals|r #a|||KEMA 97ATEX1798 U||||r #i a|||KEMA 97ATEX1798 U||
|**Clamped conductors(H05V/H07V)**|**Rated connection**|||||||**Rated connection**|||||
|solid / stranded|mm²<br>0.5...4 / 0.5...2.5|||||||0.5...6 / 0.5...4|||||
|flexible / Stranded wire with end ferrules|mm²<br>0.5...4 / 0.5...2.5|||||||0.5...4 / 0.5...4|||||
|Tighteningtorque range(clampingscrew)|0.4...0.8 Nm(M 2.5|M 2.5)||||||0.5...1.0 Nm(M 3|M 3)||||
|Tighteningtorque range(fixingscrew)|0.5...0.8 Nm|||||||0.5...1.0 Nm|||||
|Strippinglength / Blade size|mm/-<br>10 / 0.6 x 3.5 mm|||||||12 / 0.6 x 3.5 mm|||||
|**Note**|||||||||||||
|**Ordering data**|||||||||||||
|**Version**|**Type**|||**Qty.**||**Order No.**||**Type**|||**Qty.**|**Order No.**|
|green/yellow<br>EK 2.5N||||100||**0474360000**||EK 4|||100|**0354560000**|
|**Note**|||||||||||||
|**Accessories**|||||||||||||
|**Rail support**|**Type**|**Width**||**Qty.**||**Order No.**||**Type**|**Width**||**Qty.**|**Order No.**|
||SH 2|40 mm||10||**0494920000**||SH 2|40 mm||10|**0494920000**|
## **Technical data**
## **Ordering data**
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/6 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/6,5
**B.12**
**Modular PE terminals**
**B**
**==> picture [509 x 419] intentionally omitted <==**
**----- Start of picture text -----**<br>
EK 10 10 mm² EK 16 16 mm² EK 35 35 mm²<br>10 x 40 x 51.5 12 x 50 x 57.5 16 x 58 x 67.5<br> / 10 / 16 / 50<br>0.5...10 PE 2.5...16 PE 6...50 PE<br>IEC 60947-7-2 Ex e II T II 2 G D IEC 60947-7-2 IEC 60947-7-2 Ex e II T II 2 G D<br>IEC UL CSA EN 60079-7 IEC UL CSA IEC UL CSA EN 60079-7<br>10 AWG 14...6 AWG 14...6 AWG 14...6 16 AWG 10...6 AWG 10...4 35 AWG 6...2 AWG 10...2 AWG 10...2<br>800 800 800<br>8 8 8<br>720 A (6 mm²) 1920 A (16 mm²) 4200 A (35 mm²)<br>3 3 3<br>B6 / V2 B6 / V2 B9 / V2<br>r # a KEMA 97ATEX1798 U r # a r # a KEMA 97ATEX1798 U<br>Rated connection Rated connection Rated connection<br>0.5...10 / 1.5...6 2.5...16 / 2.5...16 6...16 / 16...50<br>0.5...10 / 0.5...10 2.5...16 / 4...16 10...35 / 10...35<br>1.2...1.6 Nm (M 4) 2.0...4.0 Nm (M 4) 4.0...6.0 Nm (M 6)<br>0.5...1.0 Nm 0.8...1.6 Nm 0.8...1.6 Nm<br>12 / 1.0 x 5.5 mm 16 / 1.0 x 5.5 mm 20 / 6.5 x 1.0 mm<br>Type Qty. Order No. Type Qty. Order No. Type Qty. Order No.<br>EK 10 100 0354660000 EK 16 50 0374660000 EK 35 20 0354760000<br>*UNDEFINED TEXT*<br>Type Width Qty. Order No. Type Width Qty. Order No. Type Width Qty. Order No.<br>SH 2 40 mm 10 0494920000 SH 2 40 mm 10 0494920000 SH 2 40 mm 10 0494920000<br>**----- End of picture text -----**<br>
DEK 5/5
DEK 5/5
DEK 5/5 The TS 35/15 Cu must be used when connecting conductors of 50 mm².
**B.13**
**Modular PE terminals**
**10 mm² SAKE 35**
**EK 2**
**35 mm²**
**B**
## **TS 32**
|In hazardous area applications, the installation instructions|In hazardous area applications, the installation instructions|||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|and the rated data specifications for accessories given in the||||||||||||||||||
|technical appendix must be followed.||||||||||||||||||
|Width/Length/height with TS32x7.5|mm<br>10.2 x 52 x 38|10.2 x 52 x 38||||||||14 x 46 x 39|14 x 46 x 39|||||||
|**Technical data**<br>max. current / max. cond. cross-section<br>Max. clamping range|A/mm²<br>mm²<br>**/ 10**<br>**1.5...10**<br>IEC 60947-7-2||||~~J~~|||PE||**/ 35**<br>**6...35**<br>IEC 60947-7-2||||~~=~~|||PE|
|**Rated data**|**IEC**||**UL**|**CSA**||||||**IEC**<br>**UL**|||**CSA**|||||
|Rated cross-section|mm²<br>10||AWG 16...8|AWG 16...8||||||35<br>AWG 8...2|||AWG 8...2|||||
|Rated voltage to adjacent terminal|-|||||||||||||||||
|Rated impulse withstand voltage to adjacent terminal<br>-||||||||||||||||||
|Short-time withstand current|1200 A(10 mm²)||||||||||4200 A(35 mm²)|||||||
|Pollution severity||||||||||||||||||
|Gauge to IEC 60947-1 / UL94 Flammabilityclass|||B6 / ---||||||||B8 / V-0|B8 / V-0||||||
|Approvals|r #|||||||||r #||||||||
|**Clamped conductors(H05V/H07V)**|**Rated connection**|||||||||**Rated connection**||||||||
|solid / stranded|mm²<br>1.5...10 / 1.5...10|||||||||6...35 / 6...35|6...35 / 6...35|||||||
|flexible / Stranded wire with end ferrules|mm²<br>1.5...10 / 1.5...10|||||||||6...35 / 10...35|6...35 / 10...35|||||||
|Tighteningtorque range(clampingscrew)|1.2...1.6 Nm(M 4||M 4)|||||||4.0...5.0 Nm(M 6)||||||||
|Tighteningtorque range(fixingscrew)|2.0...4.0 Nm|||||||||2.0...4.0 Nm||||||||
|Strippinglength / Blade size|mm/-<br>14 / 1.0 x 5.5 mm|||||||||16 / 6.5 x 1.2 mm||||||||
|**Note**||||||||||||||||||
|**Ordering data**||||||||||||||||||
|**Version**|**Type**||||**Qty.**|||**Order No.**||**Type**||||**Qty.**|||**Order No.**|
||EK 2||||20||**0323100000**|||SAKE 35|SAKE 35|||20||**0144400000**||
|**Note**||||||||||||||||||
|**Accessories**||||||||||||||||||
|**Rail support**|**Type**||**Width**||**Qty.**|||**Order No.**||**Type**||**Width**||**Qty.**|||**Order No.**|
||SH 2||40 mm||10||**0494920000**|||SH 2||40 mm||10||**0494920000**||
## **Technical data**
## **Ordering data**
## **Accessories**
(see assortment in catalogue 7)
**For detailed information on other accessories and applications, refer to the „Accessories“ section**
**B.14**
**Modular PE terminals**
**B**
## **SAKE 70**
## **70 mm²**
**==> picture [128 x 94] intentionally omitted <==**
**----- Start of picture text -----**<br>
18 x 94 x 59.5<br> / 70<br>10...70 =o PE<br>IEC 60947-7-2<br>IEC UL CSA<br>70 AWG 1...2/0<br>8400 A (70 mm²)<br>**----- End of picture text -----**<br>
B10 / V-0
## r #
## **Rated connection**
10...16 / 10...70 10...70 / 10...70 6.0...12 Nm (M 8) 2.0...4.0 Nm 25 /
When connecting with stranded conductors ≥ 50 mm² and 12 Nm tightening torque. Test current 8.4 kA to IK carried out via copper terminal rail
**==> picture [155 x 71] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type Qty. Order No.<br>SAKE 70/32 10 0213200000<br>Type Width Qty. Order No.<br>SH 2 40 mm 10 0494920000<br>**----- End of picture text -----**<br>
A copper TS 32 rail must be used for connecting conductors >= 50 mm².
**B.15**
**Disconnect terminals**
**SAKR**
**SAKR StB**
**4 mm²**
**B**
## **TS 32 / PA**
## **4 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [503 x 399] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|6.5 x 42 x 40.5|6.5 x 42 x 40.5|
|max. current / max. cond. cross-section|A/mm²|10 / 4|——+|—|a|10 / 4|——|+—|
|Max. clamping range|mm²|0.13...4|0.13...4|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|400|300|300|400|300|300|
|Rated current|A|10|10|10|10|10|10|
|Rated cross-section|mm²|4|AWG 22...12|AWG 22...12|4|AWG 22...12|AWG 22...12|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|6 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|A3 / V2|
|Approvals|?|# a|# a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...4 / 1.5...4|0.5...4 / 1.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...2.5|0.5...4 / 0.5...2.5|
|Tightening torque range (clamping screw)|0.5...1.0 Nm (M 3)|0.5...1.0 Nm (M 3)|
|Stripping length / Blade size|mm/-|8 / 0.6 x 3.5 mm|8 / 0.6 x 3.5 mm|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|-|
|flexible / Stranded wire with end ferrules|-|
|Note|Torque for SAKR with socket: 0.5 - 0.7 Nm.|Tightening torque via the sockets is 0.5 - 0.7 Nm.|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|beige|SAKR|100|0412160000|SAKR 2STB|100|0412260000|
|Blue|SAKR BL|100|0412180000|SAKR 2STB BL|100|0412280000|
|Note|
|Accessories|
|External cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QB 2 WI RA6 IS|27 A|50|0482700000|QB 2 WI RA6 IS|27 A|50|0482700000|
|3-pole|QB 3 WI RA6 IS|27 A|50|0482800000|QB 3 WI RA6 IS|27 A|50|0482800000|
|4-pole|QB 4 WI RA6 IS|27 A|50|0482900000|QB 4 WI RA6 IS|27 A|50|0482900000|
|Testing / Checking|Width|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 6/D3.7/2.3/M3 SAKR|100|0379400000|STB 6/D3.7/2.3/M3 SAKR|100|0379400000|
|End plate / Partition plate|
|beige|AP SAKR BE|1.5 mm|20|0211360000|AP SAKR BE|1.5 mm|20|0211360000|
|Blue|AP SAKR BL|1.5 mm|20|0211380000|AP SAKR BL|1.5 mm|20|0211380000|
|beige|
|Tropical applications|TW SAK2.5 HP/TF/GE/1|1 mm|20|0297100000|TW SAK2.5 HP/TF/GE/1|1 mm|20|0297100000|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/6,5 / SCHT 7 **For detailed information on other accessories and ap-** QB 25 blank, refer to „Accessories“ section. Note that max. conductor connec- **plications, refer to the „Accessories“ section** tion with QB = 2.5 mm². Twin wire-end ferrules ZH 0.5 - ZH 1.5 can be used.
DEK 5/6,5 / SCHT 7 QB 25 blank, refer to „Accessories“ section. Note that max. conductor connection with QB = 2.5 mm². Twin wire-end ferrules ZH 0.5 - ZH 1.5 can be used.
**B.16**
**Disconnect terminals**
**DKT 4**
**4 mm² DKT 4 V**
## **4 mm²**
**==> picture [331 x 388] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|6 x 65 x 56.5|6 x 65 x 56.5|
|10 / 4|10 / 4|
|0.13...4|0.13...4|
|IEC 60947-7-1|IEC 60947-7-1|
|IEC|UL|CSA|IEC|UL|CSA|
|400|300|300|400|
|10|10|10|10|
|4|AWG 22...12|AWG 26...12|4|
|6 / 3|6 / 3|
|A3 / V2|A3 / V2|
|r|# a|#|
|Rated connection|Rated connection|
|0.5...4 / 1.5...4|0.5...4 / 1.5...4|
|0.5...4 / 0.5...2.5|0.5...4 / 0.5...2.5|
|0.5...1.0 Nm (M 3)|0.5...1.0 Nm (M 3)|
|9 / 0.6 x 3.5 mm|9 / 0.6 x 3.5 mm|
|Type|Qty.|Order No.|Type|Qty.|Order No.|
|DKT 4|100|0687360000|DKT 4V 2STB|50|1304860000|
|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|QB 2 WI RA6 IS|27 A|50|0482700000|QB 2 WI RA6 IS|27 A|50|0482700000|
|QB 3 WI RA6 IS|27 A|50|0482800000|QB 3 WI RA6 IS|27 A|50|0482800000|
|QB 4 WI RA6 IS|27 A|50|0482900000|QB 4 WI RA6 IS|27 A|50|0482900000|
|Width|Width|
|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|AP DKT4 PA|1.5 mm|20|0687560000|AP DKT4 PA|1.5 mm|20|0687560000|
|TW SAKS2 HP/DBR/2|2 mm|20|0607000000|TW SAKS2 HP/DBR/2|2 mm|20|0607000000|
**----- End of picture text -----**<br>
**B**
DEK 5/6
DEK 5/6
**B.17**
**Disconnect terminals**
**SAKR**
**SAKR StB**
**4 mm²**
**B** a
## **TS 32 / KrG**
## **4 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
6.5 x 42 x 40.5 **10 / 4 0.13...4**
6.5 x 42 x 40.5 **10 / 4 0.13...4**
**==> picture [505 x 396] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|400|300|300|400|300|300|
|Rated current|A|10|10|10|10|10|10|
|Rated cross-section|mm²|4|AWG 22...12|AWG 22...12|4|AWG 22...12|AWG 22...12|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|6 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / 5VA|A3 / 5VA|
|Approvals|# a|r|# a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...4 / 1.5...4|0.5...4 / 1.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...2.5|0.5...4 / 0.5...2.5|
|Tightening torque range (clamping screw)|0.5...1.0 Nm (M 3)|0.5...1.0 Nm (M 3)|
|Stripping length / Blade size|mm/-|8 / 0.6 x 3.5 mm|8 / 0.6 x 3.5 mm|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|-|
|flexible / Stranded wire with end ferrules|-|
|Note|Torque for SAKR with socket: 0.5 - 0.7 Nm.|Tightening torque via the sockets is 0.5 - 0.7 Nm.|
|Ordering data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Medium yellow|SAKR KRG|100|0412120000|SAKR 2STB KRG|100|0412220000|
|Note|
|Accessories|
|Screwable cross-connection|Type|Qty.|Order No.|Type|Qty.|Order No.|
|2-pole|
|3-pole|
|4-pole|
|10-pole|
|Connecting sleeve|
|Mounting screw|
|Lock washer|
|Testing / Checking|Width|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 6/D3.7/2.3/M3 SAKR|100|0379400000|STB 6/D3.7/2.3/M3 SAKR|100|0379400000|
|End plate / Partition plate|
|Medium yellow|AP SAKR KRG|1.5 mm|20|0211320000|AP SAKR KRG|1.5 mm|20|0211320000|
|Blue|
|Medium yellow|
|Blue|
|Tropical applications|TW SAK2.5 HP/TF/GE/1|1 mm|20|0297100000|TW SAK2.5 HP/TF/GE/1|1 mm|20|0297100000|
**----- End of picture text -----**<br>
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/6,5 / SCHT 7 **For detailed information on other accessories and ap-** QB 25 blank, refer to „Accessories“ section. Note that max. conductor connec- **plications, refer to the „Accessories“ section** tion with QB = 2.5 mm². Twin wire-end ferrules ZH 0.5 - ZH 1.5 can be used.
DEK 5/6,5 / SCHT 7 QB 25 blank, refer to „Accessories“ section. Note that max. conductor connection with QB = 2.5 mm². Twin wire-end ferrules ZH 0.5 - ZH 1.5 can be used.
**B.18**
**Disconnect terminals**
**SAKC 4**
**SAKC 10**
**4 mm²**
## **10 mm²**
**==> picture [333 x 426] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|6.5 x 40 x 51.5|12 x 65 x 52.5|
|25 / 6|27 / 10|
|0.33...6|0.33...10|
|IEC 60947-7-1|IEC 60947-7-1|
|IEC|UL|CSA|IEC|UL|CSA|
|400|300|300|500|600|600|
|25|25|25|26|25|25|
|4|AWG 22...12|AWG 22...10|10|AWG 22...8|AWG 20...10|
|6 / 3|6 / 3|
|A4 / 5VA|B6 / 5VA|
|r|# a|r|# a|
|Rated connection|Rated connection|
|0.5...6 / 1.5...4|0.5...10 / 1.5...10|
|0.5...4 / 0.5...4|0.5...10 / 0.5...10|
|0.5...1.0 Nm (M 3)|1.2...2.4 Nm (M 4)|
|12 / 0.6 x 3.5 mm|12 / 1.0 x 5.5 mm|
|Tightening torque via the sockets is 0.5 - 0.7 Nm.|Tightening torque for socket is 1.2 Nm. Tightening torque is 2 Nm when|
|connecting 10-mm² stranded conductor|
|Type|Qty.|Order No.|Type|Qty.|Order No.|
|SAKC 4 KRG|100|0340720000|SAKC 10 2STB|50|0324120000|
|SAKC 4 2STB 7 order no. 0340620000|Version with socket (right), Art.no.: 0324020000 SAKC 10 STB/RE|
|Type|Qty.|Order No.|Type|current|Qty.|Order No.|
|QL 2 SAKA10|36 A|50|0135500000|
|QL 3 SAKA10|36 A|50|0135600000|
|QL 4 SAKA10|36 A|50|0135700000|
|QL 10 SAKA10|36 A|20|0338500000|
|VH 13.6/7/4.2 SAKA10|50|0299700000|
|BFSC M4X20|100|0362800000|
|SS M4 D 128-A 4|100|0136400000|
|Width|Width|
|PS 2.3 RT|5.4 mm|20|0180400000|PS 4 F.STB 4|7.6 mm|20|0299600000|
|STB 7/D4/2.3/M3 ZB/SAKC|100|0358500000|STB 17/D6/4/M4 SAKC10|50|0147100000|
|AP SAK4-10 KRG|1.5 mm|20|0117920000|AP SAKB-C-T I|3 mm|20|0146710000|
|AP SAK4-10 KRG/BL|1.5 mm|20|0117970000|
|TW SAK4-10 KRG|2.5 mm|20|0130120000|TW SAKB-C-T|3 mm|20|0242920000|
|TW SAK4-10 KRG/BL|2.5 mm|20|0130170000|
**----- End of picture text -----**<br>
DEK 5/6,5 Dummy plug and pull out tool see chapter accessories
DEK 5/6,5 Pull out force look under Accessories.
**B**
**B.19**
**Fuse terminals**
**KSKM 1**
**KSKM 2**
**10 mm²**
**B** _
## **TS 32 / PA**
**5 x 20**
## **10 mm²**
**1“ x 1/4“**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
13 x 69 x 63 **6.3 / 16** e+) **0.13...16**
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
## **Technical data**
**==> picture [281 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Rated data|IEC|UL|CSA|
|Rated voltage|V|250|600|
|Rated current|A|6.3|10|
|Rated cross-section|mm²|10|AWG 26...8|
|Rated impulse voltage / Pollution severity|kV/-|
|Gauge to IEC 60947-1 / UL94 Flammability class|B6 / V-0|
|Approvals|# a|
|Clamped conductors (H05V/H07V)|Rated connection|
|solid / stranded|mm²|0.5...16|
|flexible / Stranded wire with end ferrules|mm²|0.5...10|
|Tightening torque range (clamping screw)|1.2...2.4 Nm (M 4)|
|Stripping length / Blade size|mm/-|12 / 1.0 x 5.5 mm|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Note|
**----- End of picture text -----**<br>
**==> picture [129 x 181] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|13 x 69 x 63|
|13 / 16|a|)|a|
|0.13...16|o|t|
|IEC|UL|CSA|
|250|600|
|13|15|
|10|AWG 26...8|
|B6 / V-0|
|# a|
|Rated connection|
|0.5...16|
|0.5...10|
|1.2...2.4 Nm (M 4)|
|12 / 1.0 x 5.5 mm|
**----- End of picture text -----**<br>
## **Ordering data**
**==> picture [503 x 238] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|KSKM 1/32 G20|20|9509570000|KSKM 2/32 GZ 1X1/4|20|9509580000|
|Note|
|Accessories|
|Screwable cross-connection|Type|Qty.|Order No.|Type|Qty.|Order No.|
|2-pole|
|3-pole|
|4-pole|
|G-fuse cartridge, 5 x 20mm (IEC 60127-2)|
|0,10 A|G 20/0.10A/F|10|0430300000|
|0,20 A|G 20/0.20A/F|10|0430400000|
|0,25 A fast|G 20/0.25A/F|10|0430500000|
|0,50 A fast|G 20/0.50A/F|10|0430600000|
|0,63 A|G 20/0.63A/F|10|0439000000|
|1,00 A fast|G 20/1.00A/F|10|0430700000|
|1,60 A|G 20/1.60A/F|10|0430800000|
|2,00 A fast|G 20/2.00A/F|10|0430900000|
|2,50 A|G 20/2.50A/F|10|0431000000|
|3,15 A|G 20/3.15A/F|10|0431100000|
|4,00 A|G 20/4.00A/F|10|0431200000|
|5,00 A|G 20/5.00A/F|10|0431300000|
|6,30 A|G 20/6.30A/F|10|0431400000|
|Contact sleeve|
|SBL/1912|10|0446100000|SBL/2111|10|0446200000|
**----- End of picture text -----**<br>
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
DEK 5/5 Fuse 1“ x 1/4“ aren‘t available by Weidmüller.
**B.20**
**Fuse terminals**
**KDKS 1**
**B**
## **4 mm²**
8 x 73.5 x 55.6 **6.3 / 4 0.33...4**
**==> picture [109 x 69] intentionally omitted <==**
**----- Start of picture text -----**<br>
IEC 60947-7-3<br>IEC UL CSA<br>500 300<br>6.3 10<br>4 AWG 22...12<br>6 / 3<br>A3 / V2<br># a<br>**----- End of picture text -----**<br>
**Rated connection**
0.5...4 / 1.5...4 0.5...4 / 0.5...4 0.5...0.8 Nm (M 3) 8 / 0.6 x 3.5 mm 0.5...1.5 0.5...1.5 / 0.5...1.5
Note: max. conductor size = 2.5 mm² when using the cross-connection.
**==> picture [155 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|KDKS 1/32|50|9503300000|
|Max. power loss (1.6 W) at the cartridge fuse limits the rated current.|
**----- End of picture text -----**<br>
**==> picture [155 x 163] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Type|current|Qty.|Order No.|
|QB 2 WI RA8 IS|27 A|50|0461100000|
|QB 3 WI RA8 IS|27 A|50|0461200000|
|QB 4 WI RA8 IS|27 A|50|0461300000|
|G 20/0.10A/F|10|0430300000|
|G 20/0.20A/F|10|0430400000|
|G 20/0.25A/F|10|0430500000|
|G 20/0.50A/F|10|0430600000|
|G 20/1.00A/F|10|0430700000|
|G 20/1.60A/F|10|0430800000|
|G 20/2.00A/F|10|0430900000|
|G 20/2.50A/F|10|0431000000|
|G 20/3.15A/F|10|0431100000|
|G 20/4.00A/F|10|0431200000|
|G 20/5.00A/F|10|0431300000|
|G 20/6.30A/F|10|0431400000|
**----- End of picture text -----**<br>
DEK 5/8
**B.21**
**Fuse terminals**
**SAKS 1 5x20**
**SAKS 1 5x20**
**10 mm²**
**B** »
## **TS 32 / KrG**
## **10 mm²**
## **With LED or glow lamp**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS32x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
|Width/Length/height with TS32x7.5<br>max. current / max. cond. cross-section<br>Max. clamping range|mm<br>A/mm²<br>mm²<br>13 x 54 x 61<br>**10 / 16**<br>**0.13...16**|(<br>ob|(<br>ob|(<br>ob|(<br>ob|(<br>ob|a|a|a||13 x 54 x 61<br>**10 / 16**<br>**0.5...16**|‘|‘<br>bel.|‘<br>bel.|‘<br>bel.|‘<br>bel.|‘<br>bel.|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Technical data**||||||||||||||||||
|**Rated data**|**IEC**|**UL**|**CSA**||||||||**IEC**|**UL**||**CSA**||||
|Rated voltage|V<br>500|600|600||||||||500|||||||
|Rated current|A<br>10|6.3|10||||||||6.3|||||||
|Rated cross-section|mm²<br>10|AWG 22...10|AWG 26...10|AWG 26...10|||||||10|AWG 22...8||AWG 26...10|AWG 26...10|||
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|||||||||||4 /|4 /||||
|Gauge to IEC 60947-1 / UL94 Flammabilityclass||B6 / 5VA|B6 / 5VA|||||||||B6 / 5VA|B6 / 5VA|B6 / 5VA||||
|Approvals|? r u #i ~ a||||||||||#|||||||
|**Clamped conductors(H05V/H07V)**|**Rated connection**||||||||||**Rated connection**|||||||
|solid / stranded|mm²<br>0.5...16 / 1.5...10||||||||||0.5...16 / 1.5...10|||||||
|flexible / Stranded wire with end ferrules|mm²<br>0.5...10 / 0.5...10||||||||||0.5...10 / 0.5...10|||||||
|Tighteningtorque range(clampingscrew)|1.2...2.4 Nm(M 4|M 4)|||||||||1.2...2.4 Nm(M 4|M 4)||||||
|Strippinglength / Blade size|mm/-<br>12 / 1.0 x 5.5 mm||||||||||12 / 1.0 x 5.5 mm|||||||
|**Note**|Connections for 10-mm² stranded conductors require a tightening torque||||||||||Connections for 10-mm² stranded conductors require a tightening torque||Connections for 10-mm² stranded conductors require a tightening torque|||||
||of 2 Nm.||||||||||of 2 Nm.|||||||
|**Ordering data**||||||||||||||||||
|**Version**|**Type**|||**Qty.**|||**Order No.**||||**Type**||||**Qty.**|**Order No.**||
|500 V AC/DC<br>SAKS 1/G20||||20|||**0191220000**|||||||||||
|With GL 230 V AC/DC|||||||||||SAKS 1/32 G20 GL 230VAC|SAKS 1/32 G20 GL 230VAC|||10|**0306120000**||
|With GL 115 V AC/DC|||||||||||SAKS 1/32 G20 GL 115VAC|SAKS 1/32 G20 GL 115VAC|||10|**0385320000**||
|With LED +- 24 V DC|With LED +- 24 V DC||||||||||SAKS 1/32 G20 LD 24VDC|SAKS 1/32 G20 LD 24VDC|||10|**0371420000**||
|500 V AC/DC||||||||||||||||||
|**Note**||||||||||||||||||
|**Accessories**||||||||||||||||||
|**Screwable cross-connection**|**Type**|**current**||**Qty.**|||**Order No.**||||**Type**||||**Qty.**|**Order No.**||
||2-pole<br>QL 2 SAKS1||36 A|||50|**0191400000**|||||||||||
||3-pole<br>QL 3 SAKS1||36 A|||50|**0191500000**|||||||||||
||4-pole<br>QL 4 SAKS1||36 A|||20|**0191600000**|||||||||||
||10-pole|||||||||||||||||
|**Endplate / Partitionplate**||**Width**|||||||||||**Width**|||||
|Mediumyellow<br>AP SAKS1+3 KRG|||3 mm|||20|**0191320000**||||AP SAKS1+3 KRG|||3 mm|20|**0191320000**||
## **Technical data**
## **Ordering data**
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and ap-** Refer to „Accessories“ Chapter for cross-connection accessories **plications, refer to the „Accessories“ section**
DEK 5/5
**B.22**
**Fuse terminals**
**SAKS 1 5x25**
**B**
**10 mm² SAKS 1 5x25 10 mm² SAKS 3**
**10 mm²**
## **With glow lamp**
**==> picture [467 x 353] intentionally omitted <==**
**----- Start of picture text -----**<br>
13 x 54 x 61 13 x 54 x 61 13 x 54 x 61<br>10 / 16 6.3 / 16 10 / 16<br>0.13...16 0.5...16 0.33...16<br>IEC UL CSA IEC UL CSA IEC UL CSA<br>500 300 600 500 500 300 600<br>10 6.3 10 6.3 10 10 10<br>10 AWG 22...8 AWG 26...10 10 AWG 22...8 AWG 26...10 10 AWG 22...8 AWG 22...10<br>6 / 3 4 / 6 / 3<br>B6 / 5VA B6 / 5VA B6 / 5VA<br>? r u # i ~ a # ? # a<br>Rated connection Rated connection Rated connection<br>0.5...16 / 1.5...10 0.5...16 / 1.5...10 0.5...16 / 1.5...10<br>0.5...10 / 0.5...10 0.5...10 / 0.5...10 0.5...10 / 0.5...10<br>1.2...2.4 Nm (M 4) 1.2...2.4 Nm (M 4) 1.2...2.4 Nm (M 4)<br>12 / 1.0 x 5.5 mm 12 / 1.0 x 5.5 mm 12 / 1.0 x 5.5 mm<br>Connections for 10-mm² stranded conductors require a tightening torque Connections for 10-mm² stranded conductors require a tightening torque<br>of 2 Nm. of 2 Nm.<br>Type Qty. Order No. Type Qty. Order No. Type Qty.<br>SAKS 1/G25 20 0191120000 SAKS 3 G/5X30 500V 20<br>SAKS 1/32 G25 GL 230VAC 10 0309320000<br>SAKS 3 GZ/6.3X32 20<br>SAKS 3 1‘‘x1/4‘‘ with a red cap available under 0211120000.<br>Type current Qty. Order No. Type Qty. Order No. Type current Qty.<br>QL 2 SAKS1 36 A 50 0191400000 QL 2 SAKS1 36 A 50<br>QL 3 SAKS1 36 A 50 0191500000 QL 3 SAKS1 36 A 50<br>QL 4 SAKS1 36 A 20 0191600000 QL 4 SAKS1 36 A 20<br>QL 10 SAKS1 36 A 20 0338800000 QL 10 SAKS1 36 A 20<br>Width Width Width<br>AP SAKS1+3 KRG 3 mm 20 0191320000 AP SAKS1+3 KRG 3 mm 20 0191320000 AP SAKS1+3 KRG 3 mm 20<br>**----- End of picture text -----**<br>
|**Typeypee**|**Qty.y..**|**Order No.**|
|---|---|---|
|SAKS 3 G/5X30 500V|20|**0297520000**|
||||
||||
||||
|SAKS 3 GZ/6.3X32|20|**0248920000**|
|SAKS 3 1‘‘x1/4‘‘ with a red cap available under 0211120000.|||
||||
|**Typeypee**|**current**<br>**Qty.y..**|**Order No.**|
|QL 2 SAKS1|36 A<br>50|**0191400000**|
|QL 3 SAKS1|36 A<br>50|**0191500000**|
|QL 4 SAKS1|36 A<br>20|**0191600000**|
|QL 10 SAKS1|36 A<br>20|**0338800000**|
||**Width**||
|AP SAKS1+3 KRG|3 mm<br>20|**0191320000**|
DEK 5/5
Refer to „Accessories“ Chapter for cross-connection accessories
DEK 5/5 Refer to „Accessories“ Chapter for cross-connection accessories
DEK 5/5
**B.23**
**Fuse terminals**
**SAKS 2**
**SAKS 4**
**10 mm²**
**10 mm²**
**D 01-fuses**
**B**
## **TS 32 / KrG**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [508 x 436] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|27.6 x 80 x 75|24 x 75 x 66|
|max. current / max. cond. cross-section|A/mm²|10 / 16|16 / 16|
|Max. clamping range|mm²|0.33...16|0.33...16|
|Technical data|IEC 60947-7-3|IEC 60947-7-3|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|500|600|400|600|
|Rated current|A|10|25|16|30|
|Rated cross-section|mm²|10|AWG 22...8|10|AWG 22...8|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|6 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|B6 / 5VA|B6 / 5VA|
|Approvals|?|r|u|# i m|r|u|# ~|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...16 / 0.5...10|0.5...16 / 1.5...10|
|flexible / Stranded wire with end ferrules|mm²|0.5...10 / 0.5...10|0.5...10 / 0.5...10|
|Tightening torque range (clamping screw)|1.2...2.4 Nm (M 4)|1.2...2.4 Nm (M 4)|
|Stripping length / Blade size|mm/-|12 / 1.0 x 5.5 mm|14 / 1.0 x 5.5 mm|
|Note|Connections for stranded conductors from 10 mm² and 7-wire AWG con-|Connections for stranded conductors from 10 mm² and 7-wire AWG con-|
|ductors require a tightening torque of 2 Nm.|ductors require a tightening torque of 2 Nm.|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Without LED|SAKS 2|20|0206820000|SAKS 4|20|0321320000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAKS2|36 A|20|0207800000|QL 2 SAKS4|36 A|20|0328000000|
|3-pole|QL 3 SAKS2|36 A|20|0207900000|QL 3 SAKS4|36 A|20|0328100000|
|4-pole|QL 4 SAKS2|36 A|20|0208000000|QL 4 SAKS4|36 A|20|0328200000|
|10-pole|QL 10 SAKS2|36 A|20|0338900000|QL 10 SAKS4|36 A|20|0339000000|
|THT|Mounting screw|BFSC M4X9T|100|0103300000|BFSC M4X9T|100|0103300000|
|Lock washer|SS M4 D 128-A 4|100|0136400000|SS M4 D 128-A 4|100|0136400000|
|Screw cover cap|Width|Width|
|SK|SK E16/SAKS2|25|0284110000|SK E14 SAKS4|20|0339410000|
|Gauge rings|
|P 16/10 RT SAKS2|100|0208900000|P 14/2 D01 RS SAKS4|50|0138000000|
|P 16/16 GR SAKS2|100|0209000000|P 14/4 D01 BR SAKS4|50|0138100000|
|P 16/20 BL SAKS2|100|0209100000|P 14/10 D01 RT SAKS4|50|0328700000|
|P 14/6 D01 GN SAKS4|50|0328600000|
|Fuse cartridges|
|E 16/10A RT TNDZ|25|0208500000|E 14/2A RS|10|0137400000|
|E 16/16A GR TNDZ|25|0208600000|E 14/4A BR|10|0137500000|
|E 16/20A BL TNDZ|25|0208700000|E 14/6A GN|10|0328300000|
|E 16/25A GE TNDZ|25|0208800000|E 14/10A RT|10|0328400000|
|E 14/16A GR|10|0328500000|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 / SCHT 7 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
**B.24**
**Fuse terminals**
|**SAKS 4 USA**|**SAKS 4 USA**||||**10 mm²**|**10 mm²**|**10 mm²**|**SAKS 5**|||||**16 mm²**|**16 mm²**|**16 mm²**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**1 1/4“ x 1/4“**||||||||**D 02 - fuse**||||||||
|24 x 75 x 73||||||||28 x 80 x 66||||||||
|**30 / 16**<br>**0.5...16**||ol|||+|||**63 / 16**<br>**1.5...16**||ol<br>4} 5||||||
|||||||||IEC 60947-7-3||||||||
|**IEC**|**UL**||**CSA**|||||**IEC**|**UL**||**CSA**|||||
|400|600||600|||||400|600||600|||||
|16|30||30|||||63|40||63|||||
|10|AWG 20...8||AWG 22...8|||||16|AWG 14...6||AWG 14...6|||||
||6 / 3||||||||6 / 3|||||||
||B6 / 5VA|B6 / 5VA|B6 / 5VA||||||B7 / 5VA|B7 / 5VA|B7 / 5VA|||||
|r #a||||||||r u #~ a||||||||
|**Rated connection**||||||||**Rated connection**||||||||
|0.5...16 / 1.5...10||||||||1.5...16 / 1.5...16||||||||
|0.5...10 / 0.5...10||||||||1.5...16 / 1.5...16||||||||
|1.2...2.4 Nm(M 4|M 4)|||||||1.2...2.4 Nm(M 4)||||||||
|14 / 1.0 x 5.5 mm||||||||13 / 1.0 x 5.5 mm||||||||
|Connections for stranded conductors from 10 mm² and 7-wire AWG con-|||||||Connections for stranded conductors from 10 mm² and 7-wire AWG con-|Connections for stranded conductors from 10 mm² and 7-wire AWG con-|||||||Connections for stranded conductors from 10 mm² and 7-wire AWG con-|
|ductors require a tightening torque of 2 Nm.||ductors require a tightening torque of 2 Nm.||||||ductors require a tightening torque of 2 Nm.||ductors require a tightening torque of 2 Nm.||||||
|||||||||||||||||
|**Type**|||**Qty.**||**Order No.**|||**Type**|||**Qty.**||**Order No.**|||
|SAKS 4 USA|||20||**0162220000**|||SAKS 5 380AC|||20||**0359420000**|||
|||||||||||||||||
|||||||||||||||||
|**Type**|**current**<br>**Qty.**<br>**Order No.**|||||||**Type**|**current**<br>**Qty.**||||**Order No.**|||
|QL 2 SAKS4|||36 A|20<br>**0328000000**||||QL 2 SAKS2|||36 A|20|**0207800000**|||
|QL 3 SAKS4|||36 A|20<br>**0328100000**||||QL 3 SAKS2|||36 A|20|**0207900000**|||
|QL 4 SAKS4|||36 A|20<br>**0328200000**||||QL 4 SAKS2|||36 A|20|**0208000000**|||
|QL 10 SAKS4|||36 A|20<br>**0339000000**||||QL 10 SAKS2|||36 A|20|**0338900000**|||
|BFSC M4X9T|||100<br>**0103300000**|||||BFSC M4X9T|||100||**0103300000**|||
|SS M4 D 128-A 4|||100<br>**0136400000**|||||SS M4 D 128-A 4|SS M4 D 128-A 4||100||**0136400000**|||
|||**Width**||||||||**Width**||||||
|SK E14 SAKS4 USA|SK E14 SAKS4 USA||||1<br>**2012790000**|||SK E18 SAKS5||||20|**0359310000**|||
|||||||||||||||||
|||||||||P 18/20 D02 BL SAKS5||||50|**0361800000**|||
|||||||||P 18/25 D02 GE SAKS5||||50|**0361900000**|||
|||||||||P 18/35 D02 SW SAKS5||||50|**0362000000**|||
|||||||||P 18/50 D02 WS SAKS5||||50|**0362100000**|||
|||||||||||||||||
|||||||||E 18/20A BL||||10|**0361300000**|||
|||||||||E 18/25A GE||||10|**0361400000**|||
|||||||||E 18/50A WS||||10|**0361600000**|||
|||||||||E 18/63A KU||||10|**0361700000**|||
DEK 5/5
DEK 5/5 Partition wall TW HP (2.0) order no. 0607000000 only for TS 32
**B**
**B.25**
**Fuse inserts and gauge rings for Weidmüller fuse terminals**
**B**
## **Fuse inserts**
|**Technical data**<br>**for terminal type**<br>SAKS 1<br>SAKS 7<br>ASK 1||**Order data**<br>**G fuse inserts**5 x 20**without**indicator acc. to IEC 60127-2 (VDE 0820 T.2 Bl1)<br>**Qty.**<br>**Order No.**<br>**Size (mm)**<br>**Rated voltage (V)**<br>**Rated current (A)**<br>**Type**<br>0.1<br>(F)<br>G 20/0.10A/F<br>10<br>**0430300000**<br>5 x 20<br>0.2<br>(F)<br>G 20/0.20A/F<br>10<br>**0430400000**<br>Breaking capacity 1500 A<br>0.25<br>(F)<br>G 20/0.25A/F<br>10<br>**0430500000**|**Order data**<br>**G fuse inserts**5 x 20**without**indicator acc. to IEC 60127-2 (VDE 0820 T.2 Bl1)<br>**Qty.**<br>**Order No.**<br>**Size (mm)**<br>**Rated voltage (V)**<br>**Rated current (A)**<br>**Type**<br>0.1<br>(F)<br>G 20/0.10A/F<br>10<br>**0430300000**<br>5 x 20<br>0.2<br>(F)<br>G 20/0.20A/F<br>10<br>**0430400000**<br>Breaking capacity 1500 A<br>0.25<br>(F)<br>G 20/0.25A/F<br>10<br>**0430500000**|
|---|---|---|---|
|WSI 6||(at 250 V, 50 Hz, cos, cos:0.7)|0.5<br>(F)<br>G 20/0.50A/F<br>10<br>**0430600000**|
||||0.63<br>(F)<br>G 20/0.63A/F<br>10<br>**0439000000**|
||||1.0<br>(F)<br>G 20/1.00A/F<br>10<br>**0430700000**|
|||250|1.6<br>(F)<br>G 20/1.60A/F<br>10<br>**0430800000**|
||||2.0<br>(F)<br>G 20/2.00A/F<br>10<br>**0430900000**|
||||2.5<br>(F)<br>G 20/2.50A/F<br>10<br>**0431000000**|
||||3.15<br>(F)<br>G 20/3.15A/F<br>10<br>**0431100000**|
||||4.0<br>(F)<br>G 20/4.00A/F<br>10<br>**0431200000**|
||||5.0<br>(F)<br>G 20/5.00A/F<br>10<br>**0431300000**|
||||6.3<br>(F)<br>G 20/6.30A/F<br>10<br>**0431400000**|
|||||
||||(M)= medium-delayed action(F)= fast|
|SAKS 1||**G fuse inserts**5 x 25**with**indicator acc. to DIN 415761)<br>5 x 25 m. K.1)<br>0.25<br>(M)<br>G 25/0.25A/M<br>10<br>**0546900000**||
|SAKS 7||Breaking capacity 80 A|0.5<br>(M)<br>G 25/0.50A/M<br>10<br>**0510300000**|
|WSI 6||(at 250 V, 50 Hz, cos:= 1)|0.8<br>(M)<br>G 25/0.80A/M<br>10<br>**0646400000**|
|||250|1<br>(M)<br>G 25/1.00A/M<br>10<br>**0265800000**|
||||10<br>(M)5)<br>G 25/10.0A/M<br>10<br>**0193100000**|
||||2<br>(F)<br>G 25/2.00A/F<br>10<br>**0192700000**|
||||4<br>(F)<br>G 25/4.00A/F<br>10<br>**0192800000**|
||||6.3<br>(F)<br>G 25/6.30A/F<br>10<br>**0192900000**|
|||||
||||M)= medium-delayed action(F)= fast|
|SAKS 32)||**Fuse inserts**1¼" x ¼"**without**indicator acc. to BS 88<br>33 kA Breaking capacity 33 kA fast<br>0.5<br>GZ 0.5A/F<br>10<br>**0533800000**||
|SAKS 6||E 0.5 A|1<br>GZ 1.0A/F<br>10<br>**0525500000**|
|ce|||E 1<br>A<br>E 2<br>A<br>E 3<br>A<br>440|2<br>GZ 2.0A<br>10<br>**0294500000**<br>3<br>GZ 3.0A<br>10<br>**0295700000**<br>5<br>GZ 5.0A<br>10<br>**0294600000**<br>~~—§€N —~~|
|||E 5<br>A|7<br>GZ 7.0A<br>10<br>**0295800000**|
|||E 7<br>A|10<br>GZ 10.0A<br>10<br>**0293900000**|
|||E 10 A|12.5<br>GZ 12.5A/FF<br>10<br>**0245400000**|
|||||
||||(F)= fast(M)= miedium-delayed action|
|SAKS 2||**D fuse inserts**E 16**with**indicator acc. to DIN 49360 (diazed)<br>E 10 A<br>10<br>E 16/10A RT<br>25<br>**0208500000**||
|||E 16 A|16<br>E 16/16A GR<br>25<br>**0208600000**|
|||E 20 A<br>500|20<br>E 16/20A BL<br>25<br>**0208700000**|
|||E 25 A|25<br>E 16/25A GE<br>25<br>**0208800000**|
|||||
||||F)= fast(M)= medium-delayed action|
|SAKS 44)||**D fuse inserts**E 14 Size D 01 and E 18 size D 02**with**indicator acc. to DIN 49522 (neozed)3)<br>E 14/2<br>2<br>E 14/2A RS<br>10<br>**0137400000**||
|||E 14/4|4<br>E 14/4A BR<br>10<br>**0137500000**|
|Goo m||E 14/6<br>E 14/10<br>400<br>E 14/16|6<br>E 14/6A GN<br>10<br>**0328300000**<br>10<br>E 14/10A RT<br>10<br>**0328400000**<br>16<br>E 14/16A GR<br>10<br>**0328500000**<br>~~—&—_— [a~~|
|SAKS 5||E 18/20|20<br>E 18/20A BL<br>10<br>**0361300000**|
|||E 18/25|25<br>E 18/25A GE<br>10<br>**0361400000**|
|ie||E 18/35<br>E 18/50<br>400<br>E 18/63|35<br>E 18/35A SW<br>10<br>**0361500000**<br>50<br>E 18/50A WS<br>10<br>**0361600000**<br>63<br>E 18/63A KU<br>10<br>**0361700000**<br>~~S[€—!"—m9m9 "~~<br>~~VwX~~|
||||(F)= fast(M)= medium-delayed action|
**Note:** 1) The SIBA company also supplies 5 x 25 G fuse inserts with indicators in a shipbuilding model for 450 V AC.
- 2) 5 x 30 (500 V AC) fuse inserts for SAKS 3 are available from the WICKMANN company
3) The LINDNER company also supplies neozed fuse cartridges in an additional shipbuilding mode for 440 V AC.
> 4) Fuse cartridges with the dimensions 1“x1/4“ c 25.4x6.35 mm and 13/32“x11/2“ c 10.3x38.1 mm are not included in product line. 5) Only for SAKS 1 and SAKS 7.
**B.26**
**Fuse inserts and gauge rings for Weidmüller fuse terminals**
**B**
## **Gauge rings**
|**Gauge rings**|||||||
|---|---|---|---|---|---|---|
|**Technical data**<br>**for terminal type**<br>SAKS 4 and 4/35||**Gauge ring type**<br>P 14/2<br>P 14/4<br>P 14/6||**Amp.**<br>**Colour**<br>**Type**<br>2<br>pink<br>P 14/2D01 RS<br>4<br>brown<br>P 14/4D01 BR<br>6<br>green<br>P 14/6D01 GN||**Order data**<br>**Qty.**<br>**Order No.**<br>50<br>**0138000000**<br>50<br>**0138100000**<br>50<br>**0328600000**|
|||P 14/1||10<br>red<br>P 14/10D01 RT||50<br>**0328700000**|
||||||||
||||||||
||||||||
||||||||
|SAKS 5 and 5/35||P 18/20||20<br>blue<br>P 18/20D02 BL||50<br>**0361800000**|
|||P 18/25||25<br>yellow<br>P 18/25D02 GE||50<br>**0361900000**|
|||P 18/35||35<br>black<br>P 18/35D02 SW||50<br>**0362000000**|
|||P 18/50||50<br>white<br>P 18/50D02 WS||50<br>**0362100000**|
||||||||
||||||||
||||||||
||||||||
|SAKS 2 and 2/35||P 16/10||10<br>red<br>P 16/10 RT||100<br>**0208900000**|
|||P 16/16||16<br>grey<br>P 16/16 GR||100<br>**0209000000**|
|||P 16/20||20<br>blue<br>P 16/20 BL||100<br>**0209100000**|
**B.27**
**Terminals with spring-loaded cable clamps**
**RSF 1**
**10 mm²**
**B** |
## **TS 32**
## **RSF 3**
## **Material PA 6.6**
## **4 mm²**
## **Material KrG**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
## **Technical data**
**==> picture [159 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Rated data|
|Rated voltage|V|
|Rated current|A|
|Rated cross-section|mm²|
|Rated impulse voltage / Pollution severity|kV/-|
|Gauge to IEC 60947-1 / UL94 Flammability class|
|Approvals|
|Clamped conductors (H05V/H07V)|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|Note|
**----- End of picture text -----**<br>
8 x 50 x 60 **32 / 4 0.33...4**
**==> picture [119 x 68] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|IEC 60947-7-1|
|IEC|UL|CSA|
|630|600|600|
|32|20|25|
|4|AWG 22...12|AWG 22...12|
|6 / 3|
|/ V2|
|#|
**----- End of picture text -----**<br>
**Rated connection** 0.5...4 / 0.75...4 0.5...4 / 0.5...4 0.5...1.0 Nm (M 3) 12 / 0.6 x 3.5 mm
11 x 50 x 60 **57 / 10 0.5...10**
**==> picture [116 x 59] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|IEC 60947-7-1|
|IEC|UL|CSA|
|500|300|
|57|50|
|10|AWG 14...8|
|6 / 3|
|A5 / 5VA|
**----- End of picture text -----**<br>
#
**Rated connection** 0.5...10 / 0.5...10 1.5...4 / 0.5...6 1.2...1.6 Nm (M 4) 15 / 1.0 x 5.5 mm When used with an AWG 8/7 conductor, the tightening torque is 1.6 Nm.
## **Ordering data**
**==> picture [503 x 238] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|RSF 3 PA|50|0497560000|RSF 1 KRG|50|0270320000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAK6N|32 A|50|0194300000|QL 2 RSF1+2|57 A|50|0267400000|
|3-pole|QL 3 SAK6N|57 A|50|0194400000|QL 3 RSF1+2|57 A|50|0267500000|
|4-pole|QL 4 SAK6N|57 A|50|0194500000|QL 4 RSF1+2|41 A|50|0267600000|
|10-pole|QL 10 SAK6N|32 A|20|0338300000|QL 10 RSF1+2|41 A|20|0341700000|
|Connecting sleeve|VH 13.5/4.9/3.3 SAK4|100|0248500000|
|Mounting screw|KISC M3X20.5/10 EK4|100|0303000000|
|Lock washer|SS M3 D 128-A 3|50|0164400000|SS M3 D 128-A 3|50|0164400000|
|Switchable link|
|Switchable link|VL 2 SAK6N/SAKT|32 A|50|0194700000|VL 2 RSF 1+2|32 A|50|0528400000|
|Connecting sleeve|VH 21/5/3.5 SAK16-35|50|0309600000|VH 27/5/3.5 SAK10-35|50|0309400000|
|Mounting screw|BFSC M3X30|50|0296200000|BFSC M3X35|50|0309800000|
|Testing / Checking|Width|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 4 F.STB 4|7.6 mm|20|0299600000|
|Socket|STB 14/D5/2.3/M3 SAK2.5|50|0168600000|STB 14/D6/4/M3 SAK10|50|0169900000|
|End plate / Partition plate|
|beige|AP RSF3|3 mm|10|0270460000|
|beige|TW AST1/PA HP/DBR/0.5|0.5 mm|20|0474700000|TW AST1/PA HP/DBR/0.5|0.5 mm|20|0474700000|
|Small partition|
|Small partition|TSCH 1|2 mm|100|0319160000|
**----- End of picture text -----**<br>
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
**B.28**
**Terminals with spring-loaded cable clamps**
**RSF 2**
**B**
**6 mm²**
## **Material KrG**
11 x 77 x 73 **41 / 16 0.75...16**
|IEC 60947-7-1|IEC 60947-7-1||
|---|---|---|
||**IEC**<br>**UL**|**CSA**|
||500|300|
||41|30|
||6|AWG 14...8|
||6 / 3|6 / 3|
||/ 5VA|/ 5VA|
#
**Rated connection**
0.75...16 / 0.5...10 1.5...10 / 0.5...4 1.2...2.4 Nm (M 4) 12 / 1.0 x 5.5 mm
|**Type**|**Qty.**|**Order No.**|
|---|---|---|
|RSF 2|20|**0623320000**|
|**Type**<br>**current**<br>**Qty.**|**Order No.**|
|---|---|
|QL 2 RSF1+2<br>32 A<br>50|**0267400000**|
|QL 3 RSF1+2<br>32 A<br>50|**0267500000**|
|QL 4 RSF1+2<br>32 A<br>50|**0267600000**|
|QL 10 RSF1+2<br>32 A<br>20|**0341700000**|
|||
|||
|||
|||
|||
|||
|||
|**Width**||
|PS 4 F.STB 4<br>7.6 mm<br>20|**0299600000**|
|STB 17/D6/4/M4 SAKC10<br>50|**0147100000**|
DEK 5/5
**B.29**
**Test-disconnect terminals**
**SAKA 10**
**SAKB 10**
**10 mm²**
**10 mm²**
**B**
## **TS 32 / KrG**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS32x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
12 x 82 x 55.5 **47 / 10 0.5...10**
## **Technical data**
|**Technical data**|||||
|---|---|---|---|---|
|**Technical data**||IEC 60947-7-1|||
|**Rated data**||**IEC**<br>**UL**||**CSA**|
|Rated voltage|V|500||600|
|Rated current|A|47||35|
|Rated cross-section|mm²|10|AWG 18...8||
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|||
|Gauge to IEC 60947-1 / UL94 Flammabilityclass||B6 / 5VA|B6 / 5VA||
|Approvals||r#|||
|**Clamped conductors(H05V/H07V)**||**Rated connection**|||
|solid / stranded|mm²|0.5...10 / 1.5...10|||
|flexible / Stranded wire with end ferrules|mm²|0.5...10 / 0.5...10|||
|Tighteningtorque range(clampingscrew)||1.2...2.4 Nm(M 4)|||
|Strippinglength / Blade size|mm/-|12 / 1.0 x 5.5 mm|||
|**Note**||10 mm² stranded can be connected with 2 Nm tightening torque.|10 mm² stranded can be connected with 2 Nm tightening torque.|10 mm² stranded can be connected with 2 Nm tightening torque.|
|10 x 65 x 52.5|10 x 65 x 52.5|||
|---|---|---|---|
|**57 / 10**||||
|**0.5...10**||||
|IEC 60947-7-1||||
|**IEC**|**UL**|**CSA**||
|500||600||
|57||45||
|10||AWG 18...8||
||6 / 3|||
||B6 / 5VA|B6 / 5VA||
r # **Rated connection** 0.5...10 / 1.5...10 0.5...10 / 0.5...10 1.2...2.4 Nm (M 4) 12 / 1.0 x 5.5 mm 10 mm² stranded can be connected with 2 Nm tightening torque.
## **Ordering data**
|**Version**||**Type**|**Qty.**|**Order No.**||**Type**|**Qty.**|**Order No.**|
|---|---|---|---|---|---|---|---|---|
|Without socket||SAKA 10|25|**0134120000**||SAKB 10|50|**0134920000**|
|With open rear wall for cross-connection|||||||||
|With 2 sockets|||||||||
|With 4 sockets|||||||||
|**Note**|||||||||
|**Accessories**|||||||||
|**Screwable cross-connection**||**Type**|**current**<br>**Qty.**|**Order No.**||**Type**|**current**<br>**Qty.**|**Order No.**|
|2-pole||QL 2 SAKA10|36 A<br>50|**0135500000**||QL 2 SAKB10|47 A<br>100|**0114100000**|
|3-pole||QL 3 SAKA10|36 A<br>50|**0135600000**||QL 3 SAKB10|47 A<br>50|**0114300000**|
|4-pole||QL 4 SAKA10|36 A<br>50|**0135700000**||QL 4 SAKB10|47 A<br>50|**0114500000**|
|10-pole||QL 10 SAKA10|36 A<br>20|**0338500000**||QL 10 SAKB10|47 A<br>20|**0338400000**|
|Connectingsleeve||VH 23/6/4.2 SAKA10|50|**0348700000**|||||
|Mountingscrew||BFSC M4X30|50|**0267100000**||BFSC M4X9T|100|**0103300000**|
|**Endplate / Partitionplate**|||**Width**||||**Width**||
|Mediumyellow||AP SAKA KRG|3 mm<br>20|**0134220000**||AP SAKB/C/T KRG|3 mm<br>20|**0146720000**|
|beige|||||||||
|Mediumyellow||TW SAK2.5-35/32 KRG|3 mm<br>10|**0257120000**||TW SAKB-C-T|3 mm<br>20|**0242920000**|
|**Smallpartition**|||||||||
|Smallpartition|||||||||
|**Cross-connection slider**|||||||||
|2-pole|||||||||
|3-pole|||||||||
|4-pole|||||||||
|Connectingsleeve for QVS|||||||||
|Mountingscrew for QVS|||||||||
|**Testing / Checking**|||||||||
|Testplug||PS 4 F.STB 4|7.6 mm<br>20|**0299600000**||PS 4 F.STB 4|7.6 mm<br>20|**0299600000**|
|Socket||STB 13.5/D6/4/M4 SAKA10|50|**0135200000**||STB 16/D7/4/M4 SAK35|50|**0140200000**|
|**Miscellaneous accessories**|||||||||
|Lockout device|||||||||
|Short-circuitplug, 2-pole|||||||||
|**Marking systems**<br>(see assortment in catalogue 7)|||||||||
|Marking tags||DEK 5/5||||DEK 5/5|||
|**For detailed information on other accessories and ap-**|||||||||
|**plications, refer to the „Accessories“ section**|||||||||
## **Accessories**
**B.30**
**Test-disconnect terminals**
**SAKT 1/LT**
**SAKT 1/DU1**
**SAKT 1/QT**
**6 mm²**
**6 mm²**
**6 mm²**
8 x 65 x 52.5 **57 / 10 0.13...10**
8 x 65 x 52.5 **57 / 10 0.13...10**
8 x 65 x 52.5 **57 / 10 0.13...10**
**B** ~~o $3} 5~~ 7
|IEC 60947-7-1|IEC 60947-7-1||IEC 60947-7-1|IEC 60947-7-1||
|---|---|---|---|---|---|
|**IEC**|**UL**|**CSA**|**IEC**|**UL**|**CSA**|
|400|300|300|400|300|300|
|41|25|25|41|25|25|
|6|AWG 22...8|AWG 26...8|6|AWG 22...8|AWG 26...8|
||6 / 3|||6 / 3||
||A5 / 5VA|A5 / 5VA||A5 / 5VA|A5 / 5VA|
|r#|||#|||
|**Rated connection**|||**Rated connection**|||
|0.5...10 / 1.5...10|||0.5...10 / 1.5...10|||
|0.5...6 / 0.5...6|||0.5...6 / 0.5...6|||
|0.8...1.6 Nm(M 3.5)|||0.8...1.6 Nm(M 3.5)|||
|12 / 4.0 x 0.8 mm|||12 / 4.0 x 0.8 mm|||
|10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm|10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm||10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm|10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm||
|tightening torque.|||tightening torque.|||
|IEC 60947-7-1|IEC 60947-7-1||
|---|---|---|
|**IEC**|**UL**|**CSA**|
|400|300|300|
|41|25|25|
|6|AWG 22...8|AWG 26...8|
||6 / 3||
||A5 / 5VA|A5 / 5VA|
|r#|||
|**Rated connection**|||
|0.5...10 / 1.5...10|||
|0.5...6 / 0.5...6|||
|0.8...1.6 Nm(M 3.5)|||
|12 / 4.0 x 0.8 mm|||
|10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm|10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm||
|tightening torque.|||
|**Type**||**Qty.**|**Order No.**|
|---|---|---|---|
|SAKT 1/LT|SAKT 1/LT|50|**0269120000**|
|||||
|SAKT 1/LT STB14/4|SAKT 1/LT STB14/4|50|**0437920000**|
|**Type**||**Qty.**<br>**Order No.**|
|---|---|---|
|SAKT 1/DU2|SAKT 1/DU2|50<br>**0550420000**|
|SAKT 1/DU1|SAKT 1/DU1|50<br>**0195620000**|
|**Type**||**Qty.**|**Order No.**|
|---|---|---|---|
|SAKT 1/QT2|SAKT 1/QT2|50|**0494820000**|
|SAKT 1/QT1|SAKT 1/QT1|50|**0269320000**|
|**Type**|**current**<br>**Qty.**<br>**Order No.**||**Type**|**current**<br>**Qty.**|**Order No.**||**Type**|**current**<br>**Qty.**|**Order No.**|
|---|---|---|---|---|---|---|---|---|---|
|QL 2 SAK6N|57 A<br>50<br>**0194300000**||QL 2 SAK6N|57 A<br>50|**0194300000**||QL 2 SAK6N|32 A<br>50|**0194300000**|
|QL 3 SAK6N|57 A<br>50<br>**0194400000**||QL 3 SAK6N|57 A<br>50|**0194400000**||QL 3 SAK6N|57 A<br>50|**0194400000**|
|QL 4 SAK6N|57 A<br>50<br>**0194500000**||QL 4 SAK6N|57 A<br>50|**0194500000**||QL 4 SAK6N|57 A<br>50|**0194500000**|
|QL 10 SAK6N|57 A<br>20<br>**0338300000**||QL 10 SAK6N|57 A<br>20|**0338300000**||QL 10 SAK6N|32 A<br>20|**0338300000**|
|VH 12/4.9/3.3 SAK6N|100<br>**0249000000**||VH 12/4.9/3.3 SAK6N|100|**0249000000**||VH 12/4.9/3.3 SAK6N|100|**0249000000**|
|KISC M3X20 SAK10 CU5|100<br>**0377100000**||KISC M3X20 SAK10 CU5|100|**0377100000**||KISC M3X20 SAK10 CU5|100|**0377100000**|
||**Width**|||**Width**||||**Width**||
|AP SAKB/C/T KRG|3 mm<br>20<br>**0146720000**||AP SAKB/C/T KRG|3 mm<br>20|**0146720000**||AP SAKB/C/T KRG|3 mm<br>20|**0146720000**|
|TW SAKB/C/T1|1.5 mm<br>20<br>**0242960000**||TW SAKB/C/T1|1.5 mm<br>20|**0242960000**||TW SAKB/C/T1|1.5 mm<br>20|**0242960000**|
|||||||||||
|||||||||||
|TSCH 2|0.6 mm<br>100<br>**0353660000**||TSCH 2|0.6 mm<br>100|**0353660000**||TSCH 2|0.6 mm<br>100|**0353660000**|
||**current**|||**current**||||**current**||
|QVS 2 SAKT1+2|20<br>**0307300000**||QVS 2 SAKT1+2|20|**0307300000**||QVS 2 SAKT1+2|41 A<br>20|**0307300000**|
|QVS 3 SAKT1+2|20<br>**0329300000**||QVS 3 SAKT1+2|20|**0329300000**||QVS 3 SAKT1+2|41 A<br>20|**0329300000**|
|QVS 4 SAKT1+2|20<br>**0307400000**||QVS 4 SAKT1+2|20|**0307400000**||QVS 4 SAKT1+2|41 A<br>20|**0307400000**|
|VH 19/6/4.2 SAKT1|50<br>**0318000000**||VH 19/6/4.2 SAKT1|50|**0318000000**||VH 19/6/4.2 SAKT1|50|**0318000000**|
|BS 25 O.IH SAKT1|50<br>**0334700000**||BS 25 O.IH SAKT1|50|**0334700000**||BS 25 O.IH SAKT1|50|**0334700000**|
||**Width**|||**Width**||||**Width**||
|PS 4 F.STB 4|7.6 mm<br>20<br>**0299600000**||PS 4 F.STB 4|7.6 mm<br>20|**0299600000**||PS 4 F.STB 4|7.6 mm<br>20|**0299600000**|
|STB 14/D6/4/M3 SAK10|50<br>**0169900000**||STB 14/D6/4/M3 SAK10|50|**0169900000**||STB 14/D6/4/M3 SAK10|50|**0169900000**|
|||||||||||
|SSP 3 SAKT1|100<br>**0531760000**||SSP 3 SAKT1|100|**0531760000**||SSP 3 SAKT1|100|**0531760000**|
|QS 2/8/4|20<br>**0270960000**||QS 2/8/4|20|**0270960000**||QS 2/8/4|20|**0270960000**|
DEK 5/6,5 DEK 5/6,5 To safe the test sockets use the SDIZ-blade (see chapter Tools) or bits To safe the test sockets use the SDIZ-blade (see chapter Tools) or bits with pilots! with pilots!
DEK 5/6,5 To safe the test sockets use the SDIZ-blade (see chapter Tools) or bits with pilots!
**B.31**
**Test-disconnect terminals**
**SAKT 2/LT**
**SAKT 4/LT**
**6 mm²**
**4 mm²**
**B** _
## **TS 32 / KrG**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [509 x 174] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|8 x 82 x 52.5|8 x 57.2 x 42.5|
|max. current / max. cond. cross-section|A/mm²|46 / 10|41 / 6|
|Max. clamping range|mm²|0.5...10|0.13...6|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|125|300|400|300|300|
|Rated current|A|41|25|32|20|20|
|Rated cross-section|mm²|6|AWG 22...8|4|AWG 22...12|AWG 26...10|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|6 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A5 / 5VA|A3 / 5VA|
|Approvals|# a|r # a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...10 / 1.5...10|0.5...6 / 1.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...6 / 0.5...6|0.5...4 / 0.5...4|
|Tightening torque range (clamping screw)|1.2...1.6 Nm (M 3.5)|0.4...0.7 Nm (M 2.5)|
|Stripping length / Blade size|mm/-|12 / 4.0 x 0.8 mm|10 / 0.6 x 3.5 mm|
|Note|10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm|Two conductors with the same cross-section can be accommodated. 1.5|
|tightening torque.|mm² solid and 0.5...1.5 mm² flexible|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering data**
**==> picture [509 x 364] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Without socket|SAKT 2/LT O.STB|50|0445420000|SAKT 4/LT O.STB|50|0254120000|
|With open rear wall for cross-connection|
|With 2 sockets|SAKT 2/LT STB|50|0330620000|SAKT 4/LT STB2.0|50|0310320000|
|With 4 sockets|SAKT 2/LT 4STB|50|0437720000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAK6N|32 A|50|0194300000|QL 2 SAK2.5|41 A|100|0155900000|
|3-pole|QL 3 SAK6N|57 A|50|0194400000|QL 3 SAK2.5|41 A|100|0156000000|
|4-pole|QL 4 SAK6N|57 A|50|0194500000|QL 4 SAK2.5|41 A|50|0156100000|
|10-pole|QL 10 SAK6N|32 A|20|0338300000|QL 10 SAK2.5|41 A|20|0338100000|
|Connecting sleeve|VH 12/4.9/3.3 SAK6N|100|0249000000|VH 8/4.9/3.3 SAK2.5|100|0266700000|
|ttt|rr|
|Mounting screw|KISC M3X20 SAK10 CU5|100|0377100000|KISC M3X15/6 SAK2.5 CU5|100|0377200000|
|End plate / Partition plate|Width|Width|
|Medium yellow|AP SAKB/C/T KRG|3 mm|20|0146720000|
|beige|TW SAKB/C/T1|1.5 mm|20|0242960000|TW AST1/PA HP/DBR/0.5|0.5 mm|20|0474700000|
|Medium yellow|
|Small partition|
|Small partition|TSCH 2|0.6 mm|100|0353660000|
|Cross-connection slider|current|current|
|2-pole|QVS 2 SAKT1+2|41 A|20|0307300000|QVS 2/4 SAKT4|32 A|20|1319260000|
|3-pole|QVS 3 SAKT1+2|41 A|20|0329300000|
|4-pole|QVS 4 SAKT1+2|41 A|20|0307400000|
|Connecting sleeve for QVS|VH 19/6/4.2 SAKT1|50|0318000000|VH 16/5/3.5 SAK10-35|50|0309700000|
|ut|—§—N_|
|Mounting screw for QVS|BS 25 O.IH SAKT1|50|0334700000|ao oe|BFSC M3X22 SAKT4|50|1319900000|
|Testing / Checking|Width|Width|
|Test plug|PS 4 F.STB 4|7.6 mm|20|0299600000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 14/D6/4/M3 SAK10|50|0169900000|STB 8.5/5/2.3/M3 SAK2.5|50|0280600000|
|Miscellaneous accessories|
|Lockout device|SSP 3 SAKT1|100|0531760000|SSP 4 SAKT4|20|1319360000|
|Short-circuit plug, 2-pole|QS 2/8/4|20|0270960000|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/6,5|DEK 5/6,5|
|For detailed information on other accessories and ap-|To safe the test sockets use the SDIZ-blade (see chapter Tools) or bits|To safe the test sockets use the SDIZ-blade (see chapter Tools) or bits|
|plications, refer to the „Accessories“ section|with pilots!|with pilots!|
**----- End of picture text -----**<br>
## **Accessories**
**B.32**
**B**
**B.33**
**Terminals for temperature measuring circuits**
**2.5 mm² DK 4 TC**
**B** 7
## **TS 32 / PA**
**SAK 2.5/TC**
**4 mm²**
Busbars from thermocouple materials, according to DIN IEC 584.
**==> picture [503 x 309] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|In hazardous area applications, the installation instructions|
|and the rated data specifications for accessories given in the|
|technical appendix must be followed.|
|Width/Length/height with TS32x7.5|mm|6 x 36.5 x 46.5|6 x 54 x 59.5|
|max. current / max. cond. cross-section|A/mm²|/ 2.5|:|:|/ 4|||
|Max. clamping range|mm²|...2.5|...4|
|Technical data|IEC 60947-7-1 / IEC 60584|IEC 60947-7-1 / IEC 60584|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|
|Rated current|A|
|Rated cross-section|mm²|2.5|4|
|Rated impulse voltage / Pollution severity|kV/-|/ 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|/ V2|A3 / V2|
|Approvals|#|#|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...2.5|0.5...4 / 1.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...2.5|
|Tightening torque range (clamping screw)|0.4...0.6 Nm (M 2.5)|0.5...1.0 Nm (M 3)|
|Stripping length / Blade size|mm/-|10 / 0.6 x 3.5 mm|9 / 0.6 x 3.5 mm|
|Note|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|NiCr|SAK 2.5/TC CH|100|0107260000|
|Ni|SAK 2.5/TC AL|100|0107160000|
|CuNi|SAK 2.5/TC CO|100|0189860000|
|Fe|SAK 2.5/TC FE|100|0190060000|
|Cu|SAK 2.5/TC CU|100|0189960000|
|(NiCr - Ni) type KNiCr - Ni) type K) type K type Kype Ke K|DK 4Q/TC TYP K|100|1338260000|
|(Cu - CuNi) type TCu - CuNi) type T) type T type Type Te T|DK 4Q/TC TYP T|100|1338160000|
|(Fe-CuNi) tFe-CuNi) t) t type J|e J|DK 4Q/TC TYP J|100|1338060000|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
NiCr Ni CuNi Fe Cu (NiCr - Ni) type KNiCr - Ni) type K) type K type Kype Ke K (Cu - CuNi) type TCu - CuNi) type T) type T type Type Te T (Fe-CuNi) tFe-CuNi) t) t type J
**Note**
## **Accessories**
**==> picture [329 x 35] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|End plate / Partition plate|Type|Width|Qty.|Order No.|
|beige|AP SAK2.5|1.5 mm|20|0279560000|
|beige|TW SAK2.5|2.5 mm|20|0302860000|
|Dark beige Wemid|
**----- End of picture text -----**<br>
**==> picture [155 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Type|Width|Qty.|Order No.|
|AP DK4Q|1.5 mm|20|1397160000|
|TW SAKS2 HP/DBR/2|2 mm|20|0607000000|
|WTW EN|3 mm|20|1058800000|
**----- End of picture text -----**<br>
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/6 / SCHT 7 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/6
**B.34**
**Terminals for temperature measuring circuits**
**SAK 2.5/TC / DK 4 TC**
**B**
Weidmüller thermocouple terminals are specially designed for the transmission of very small voltages in temperature measuring circuits. Special current bars ensure that no false signals are transmitted within the terminal when temperature differences between the positive and negative paths exist. This high measuring precision is required, for example, in aircraft engine test rigs, complicated chemical processes, controllers, etc.
- Material of current bar corresponds to thermal and compensating conductors
- Clear thermocouple marking
- 2-pole blocks per thermocouple
- Modular width 10 mm
## **Configuration of a temperature measuring circuit**
**==> picture [161 x 72] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2 3 4 5 6<br>CH<br>AL<br>1 Thermocouple (sensor) 4 Reference junction<br>2 Thermocouple terminals 5 Supply and return conductors<br>3 Compensating conductor 6 Measuring instrument<br>**----- End of picture text -----**<br>
The thermocouple terminals shown in this measuring circuit are used for the thermoelectrical transmission of the thermoelectric voltage from the thermocouple to the reference junction and the indicator unit via the compensating conductor. Thermocouple terminals are required for constructing a temperature measuring circuit.
## **Technical data**
Thermocouples to IEC 584 (DIN 43 710)
|||Busbar material|
|---|---|---|
||Terminal|trade name|
|**a) Type J**|||
|**Fe**||Iron|
|(positive leg)|||
|**CuNi**||Constantan|
|(negative leg)|||
|**b) Type T**|||
|**Cu**||Copper|
|(positive leg)|||
|**CuNi**||Constantan|
|(negative leg)|||
|**c) Type K**|||
|**NiCr**||Chromel|
|(positive leg)|||
|**Ni**||Alumel|
|(negative leg)|||
**B.35**
**Terminals with screw-less connections**
**AST 3**
**2.5 mm²**
**2.5 mm²**
**B**
## **with push-on connection TS 32 / PA**
## **AST 1**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-sectionMax. clamping range|A/mm²mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [508 x 174] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|6.5 x 58 x 46|F6,3|F6,3|F6,3|F6,3|6.5 x 40 x 46|6,3|6,3|
|max. current / max. cond. cross-sectionMax. clamping range|A/mm²mm²|20 / 2.50.5...2.5|F2,8|Lr|F2,8|fe|yy|F2,8|F2,8|20 / 2.50.5...2.5|2,8|L|ay|2,8|
|Technical data|IEC 60947-7-1 / IEC 61210|IEC 60947-7-1 / IEC 61210|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|500|600|300|500|300|300|
|Rated current|A|20|13|16|20|13|16|
|Rated cross-section|mm²|2.5|2.5|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|6 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|/ V2|/ 5VA|
|Approvals|r|u # a|#|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|0.5...2.5|0.5...2.5|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|Note|Cable-lug connections should be fitted with insulating sleeves. 20 A with|The rated voltage is 800 V when using a cable-lug (flat) connector with IH|
|F 6.3 or 2 x F 2.8|6.3 insulating sleeves.|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering data**
**==> picture [155 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|AST 1 6.3/2.8|50|0478260000|
|AST 1 6.3|50|0266360000|
**----- End of picture text -----**<br>
**==> picture [160 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|AST 3 6.3|100|0236760000|
|Cable-lug connections should be connected with insulating sleeves. 20 A|
|with F 6.3 or 2 x F 2.8|
**----- End of picture text -----**<br>
**Version Note**
**==> picture [503 x 257] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Slotted|AST 1 6.3/2.8|50|0478260000|
|Not slit|AST 1 6.3|50|0266360000|AST 3 6.3|100|0236760000|
|Note|Cable-lug connections should be connected with insulating sleeves. 20 A|
|with F 6.3 or 2 x F 2.8|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|Q 2 SAK4|41 A|50|0336700000|Q 2 SAK4|41 A|50|0336700000|
|3-pole|Q 3 SAK4|41 A|50|0336800000|Q 3 SAK4|41 A|50|0336800000|
|4-pole|Q 4 SAK4|41 A|50|0336900000|Q 4 SAK4|41 A|50|0336900000|
|10-pole|Q 10 SAK4|41 A|20|0368800000|Q 10 SAK4|41 A|20|0368800000|
|Plug-in adapter|Width|Width|
|2-pole|STA 2.5/2|100|0165860000|STA 2.5/2|100|0165860000|
|3-pole|STA 2.5/3|50|0165960000|STA 2.5/3|50|0165960000|
|4-pole|STA 2.5/4|50|0190360000|STA 2.5/4|50|0190360000|
|5-pole|STA 2.5/5|50|0166060000|STA 2.5/5|50|0166060000|
|8-pole|STA 2.5/8|50|0166160000|STA 2.5/8|50|0166160000|
|End plate / Partition plate|
|beige|AP AST1+5 DB|1.5 mm|20|0266400000|AP SAK2.5/35 + AST3+4|1.5 mm|20|0460560000|
|beige|TW AST1/PA HP/DBR/0.5|0.5 mm|20|0474700000|TW SAKS2 HP/DBR/2|2 mm|20|0607000000|
|Small partition|
|Small partition|TSCH 1|2 mm|100|0319160000|TSCH 1|2 mm|100|0319160000|
|Testing / Checking|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 14/D5/2.3/M3 SAK2.5|50|0168600000|STB 14/D5/2.3/M3 SAK2.5|50|0168600000|
|Insulating sleeve|
|2,8|IH 2.8 DB|100|0386060000|IH 2.8 DB|100|0386060000|
|6,3|IH 6.3 WEM GE|100|0386260000|IH 6.3 WEM GE|100|0386260000|
**----- End of picture text -----**<br>
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/6,5
DEK 5/6
**B.36**
**Terminals with screw-less connections**
**SAK 4 S**
**4 mm² SAK 4 SS**
**2.5 mm² DK 4 S**
**B**
**4 mm²**
**==> picture [505 x 472] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|6.5 x 40 x 51.5|20 / 6|6,32,8|6.5 x 40 x 51.5|20 / 2.5|6,32,8|6,32,8|6 x 54 x 59.5|20 / 4|6,32,8|6,32,8|
|6,3|6,3|6,3|
|0.13...6|2,8|0.5...2.5|2,8|2,8|0.33...4|
|—t.|2|ay|
|IEC 60947-7-1 / IEC 61210|IEC 60947-7-1 / IEC 61210|IEC 60947-7-1 / IEC 61210|
|IEC|UL|CSA|IEC|UL|CSA|IEC|UL|CSA|
|500|300|300|500|600|300|400|300|300|
|20|13|13|20|13|13|10|10|10|
|4|AWG 26...12|AWG 26...12|2.5|AWG 18...14|AWG 18...14|4|AWG 22...12|AWG 22...12|
|6 / 3|6 / 3|6 / 3|
|A4 / V2|/ V2|A3 / V2|
|u # a # a|r|u # a # a|r|u # a|
|Rated connection|Rated connection|Rated connection|
|0.33...6 / 1.5...4|0.5...4 / 1.5...4|
|0.5...4 / 0.5...4|0.5...2.5|0.5...4 / 0.5...2.5|
|0.5...1.0 Nm (M 3)(M 3)M 3))|0.5...0.8 Nm (M 3)|
|12 / 0.6 x 3.5 mm|8 / 0.6 x 3.5 mm|
|Cable-lug connections should be fitted with insulating sleeves. 20 A with|Cable-lug connections should be fitted with insulating sleeves. 20 A with|Cable-lug connections should be fitted with insulating sleeves. 20 A sup-|
|F 6.3 or 2 x F 2.8|F 6.3 or 2 x F 2.8|plied via F 6.3 or 2 x F 2.8.|
|Typeypee|Qty.y..|Order No.|Typeypee|Qty.y..|Order No.|Type|Qty.|Order No.|
|SAK 4 S 6.3/2.8|100|0401260000|SAK 4 SS 6.3/2.8|100|0479660000|DK 4S SF 6.3/2.8|100|0631260000|
|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|QL 2 SAK4|32 A|100|0130600000|QL 2 SAK4|32 A|100|0130600000|Q 2 AKZ4|32 A|50|0336400000|
|QL 3 SAK4|32 A|100|0130700000|QL 3 SAK4|32 A|100|0130700000|Q 3 AKZ4|32 A|50|0336500000|
|QL 4 SAK4|32 A|50|0130800000|QL 4 SAK4|32 A|50|0130800000|Q 4 AKZ4|32 A|50|0336600000|
|QL 10 SAK4|32 A|20|0338200000|QL 10 SAK4|32 A|20|0338200000|Q 10 AKZ4|32 A|20|0368600000|
|Width|Width|Width|
|AP SAK4-10|1.5 mm|20|0117960000|AP SAK4-10|1.5 mm|20|0117960000|AP DK4S|20|0631360000|
|TW 4 SAK4-10|1.5 mm|20|0130160000|TW 4 SAK4-10|1.5 mm|20|0130160000|
|TSCH 6 DKI S4|5 mm|100|0190260000|
|PS 2.3 RT|5.4 mm|20|0180400000|
|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|IH 2.8 DB|100|0386060000|IH 2.8 DB|100|0386060000|IH 2.8 DB|100|0386060000|
|IH 6.3 WEM GE|100|0386260000|IH 6.3 WEM GE|100|0386260000|IH 6.3 WEM GE|100|0386260000|
**----- End of picture text -----**<br>
**==> picture [334 x 214] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|6.5 x 40 x 51.5|6.5 x 40 x 51.5|
|20 / 6|2,86,32,8|20 / 2.5|2,86,32,8|2,86,32,8|
|6,3|6,3|6,3|
|0.13...6|2,8|0.5...2.5|2,8|2,8|
|—t.|2|
|IEC 60947-7-1 / IEC 61210|IEC 60947-7-1 / IEC 61210|
|IEC|UL|CSA|IEC|UL|CSA|
|500|300|300|500|600|300|
|20|13|13|20|13|13|
|4|AWG 26...12|AWG 26...12|2.5|AWG 18...14|AWG 18...14|
|6 / 3|6 / 3|
|A4 / V2|/ V2|
|r|u # a # a|r|u # a # a|
|Rated connection|Rated connection|
|0.33...6 / 1.5...4|
|0.5...4 / 0.5...4|0.5...2.5|
|0.5...1.0 Nm (M 3)(M 3)M 3))|
|12 / 0.6 x 3.5 mm|
|Cable-lug connections should be fitted with insulating sleeves. 20 A with|Cable-lug connections should be fitted with insulating sleeves. 20 A with|
|F 6.3 or 2 x F 2.8|F 6.3 or 2 x F 2.8|
|Typeypee|Qty.y..|Order No.|Typeypee|Qty.y..|Order No.|
|SAK 4 S 6.3/2.8|100|0401260000|SAK 4 SS 6.3/2.8|100|0479660000|
**----- End of picture text -----**<br>
DEK 5/6,5
DEK 5/6
DEK 5/6,5
**B.37**
**Terminals with screw-less connections**
**SAK 2.5 T 1x1**
**DK 4 T**
**B**
## **with Termi-Point / Wire-Wrap connection TS 32 / PA**
## **2.5 mm²**
**4 mm²**
|In hazardous area applications, the installation instructions|In hazardous area applications, the installation instructions||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|and the rated data specifications for accessories given in the|||||||||||||||
|technical appendix must be followed.|||||||||||||||
|Width/Length/height with TS32x7.5|mm<br>6 x 36.5 x 67||||||6 x 50 x 77.5|||||||1x1|
|max. current / max. cond. cross-section<br>A/mm²<br>Max. clamping range<br>mm²<br>**8 / 6**<br>**0.33...6**|||||||**10 / 6**<br>**0.5...6**|||1x1<br>~~Oo~~|||||
|**Technical data**|IEC 60947-7-1||||||IEC 60947-7-1 / IEC 61210||IEC 60947-7-1 / IEC 61210||||||
|**Rated data**|**IEC**|**UL**|**CSA**||||**IEC**||**UL**|||**CSA**|||
|Rated voltage|V<br>250||300||||250||300|||300|||
|Rated current|A<br>8||10||||10||10|||10|||
|Rated cross-section|mm²<br>2.5|AWG 22...12||AWG 22...12|||4|AWG 22...12|||AWG 22...12||AWG 22...12||
|Rated impulse voltage / Pollution severity|kV/-|4 / 3|||||||4 / 3|4 / 3|||||
|Gauge to IEC 60947-1 / UL94 Flammabilityclass||A3 / V2|||||||A3 / V2|A3 / V2|||||
|Approvals|#||||||r# a||||||||
|**Clamped conductors(H05V/H07V)**|**Rated connection**||||||**Rated connection**||||||||
|solid / stranded|mm²<br>0.5...6 / 0.5...2.5||||||0.5...6 / 1.5...4||||||||
|flexible / Stranded wire with end ferrules|mm²<br>0.5...4 / 0.5...2.5||||||0.5...4 / 0.5...2.5||||||||
|Tighteningtorque range(clampingscrew)|0.4...0.7 Nm(M 2.5)||||||0.5...0.8 Nm(M 3|M 3)|||||||
|Strippinglength / Blade size|mm/-<br>10 / 0.6 x 3.5 mm||||||8 / 0.6 x 3.5 mm||||||||
|**Note**|||||||||||||||
|**Ordering data**|||||||||||||||
|**Version**|**Type**|||**Qty.**|**Order No.**||**Type**||||||**Qty.**|**Order No.**|
||right<br>SAK 2.5 SW 1X1|||100|**0108560000**||DK 4 SW 1X1||||||50|**0536560000**|
|**Note**|||||||||||||||
|**Accessories**|||||||||||||||
|**Screwable cross-connection**|**Type**|**current**||**Qty.**|**Order No.**||**Type**||**current**||||**Qty.**|**Order No.**|
||2-pole<br>Q 2 SAK2.5|41 A|41 A|50|**0337000000**||Q 2 AKZ4||||32 A|32 A|50|**0336400000**|
||3-pole<br>Q 3 SAK2.5|41 A|41 A|50|**0337100000**||Q 3 AKZ4||||32 A|32 A|50|**0336500000**|
||4-pole<br>Q 4 SAK2.5|41 A|41 A|50|**0337200000**||Q 4 AKZ4||||32 A|32 A|50|**0336600000**|
||10-pole<br>Q 10 SAK2.5|41 A|41 A|20|**0368700000**||Q 10 AKZ4||||32 A|32 A|20|**0368600000**|
|**Endplate / Partitionplate**||**Width**||||||||**Width**|||||
||beige<br>AP SAK2.5|1.5 mm||20|**0279560000**||AP DK4||1.5 mm||||20|**0359260000**|
||Blue||||||AP DK4 BL||1.5 mm||||20|**0359280000**|
||beige<br>TW SAK2.5|2.5 mm||20|**0302860000**||TW SAKS2 HP/DBR/2||||2 mm||20|**0607000000**|
|**Smallpartition**|||||||||||||||
||Smallpartition<br>TSCH 1|2 mm||100|**0319160000**||TSCH 4 AKZ4||||6 mm||100|**0363360000**|
|**External cross-connection**|||||||||**current**||||||
||2-pole||||||QB 2 WI RA6 IS||||27 A|27 A|50|**0482700000**|
||3-pole||||||QB 3 WI RA6 IS||||27 A|27 A|50|**0482800000**|
||4-pole||||||QB 4 WI RA6 IS||||27 A|27 A|50|**0482900000**|
|**Testing / Checking**||||||||||**Width**|||||
||Testplug<br>PS 2.3 RT|5.4 mm||20|**0180400000**||PS 2.3 RT||5.4 mm||||20|**0180400000**|
||Socket<br>STB 8.5/5/2.3/M3 SAK2.5|||50|**0280600000**||STB 8.5/D4/2.3/M2.5 AKZ||||||50|**0215700000**|
## **Technical data**
## **Ordering data**
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/6 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/6
**B.38**
**Terminals with screw-less connections**
**B** |
## **with solder connection TS 32 / PA**
**SAKRT**
**4 mm² SAK 2.5 L**
## **2.5 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
6.5 x 42 x 40.5 **8 / 4 0.5...4**
6 x 44.5 x 46.5 **17.5 / 6 0.33...6**
## **Technical data**
**==> picture [505 x 520] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|IEC 60947-7-1|IEC 60947-7-1 / IEC 60068-2-20|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|250|300|250|300|
|Rated current|A|8|10|17.5|10|
|Rated cross-section|mm²|4|AWG 22...12|2.5|AWG 22...12|
|Rated impulse voltage / Pollution severity|kV/-|4 / 3|4 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|A3 / V2|
|Approvals|r #|#|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...4 / 1.5...4|0.5...6 / 0.5...2.5|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...2.5|0.5...4 / 0.5...2.5|
|Tightening torque range (clamping screw)|0.5...1.0 Nm (M 3)|0.4...0.7 Nm (M 2.5)|
|Stripping length / Blade size|mm/-|8 / 0.6 x 3.5 mm|10 / 0.6 x 3.5 mm|
|Note|QB 25 blank, refer to „Accessories“ section. Note that max. conductor connec-|max 1.5 mm² conductor via solder connection|
|tion with QB = 2.5 mm². Twin wire-end ferrules ZH 0.5 - ZH 1.5 can be used.|
|Ordering data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|beige|
|right|SAK 2.5 SL|100|0351460000|
|left|SAKR TS SE 1.6|100|0469360000|
|Note|
|Accessories|
|Screwable cross-connection|Type|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|Q 2 SAK2.5|41 A|50|0337000000|
|3-pole|Q 3 SAK2.5|41 A|50|0337100000|
|4-pole|Q 4 SAK2.5|41 A|50|0337200000|
|10-pole|Q 10 SAK2.5|41 A|20|0368700000|
|External cross-connection|current|
|2-pole|QB 2 WI RA6 IS|27 A|50|0482700000|
|3-pole|QB 3 WI RA6 IS|27 A|50|0482800000|
|4-pole|QB 4 WI RA6 IS|27 A|50|0482900000|
|End plate / Partition plate|Width|Width|
|beige|AP SAKR BE|1.5 mm|20|0211360000|AP SAK2.5|1.5 mm|20|0279560000|
|Blue|AP SAK2.5 BL|1.5 mm|20|0279580000|
|beige|TW SAKS2 HP/DBR/2|2 mm|20|0607000000|TW SAK2.5|2.5 mm|20|0302860000|
|Blue|TW SAK2.5 BL|1.5 mm|20|0302880000|
|Small partition|
|Small partition|TSCH 1|2 mm|100|0319160000|
|Cover / warning label|
|Cover / warning label|AD 4 AKZ4|50|0303400000|
|Mounting screw (plastic)|BFSC M3X22 PA/RT|100|0128900000|
|Testing / Checking|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/5/2.3/M3 SAK2.5|50|0280600000|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/6,5|DEK 5/6|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
**B.39**
**Terminals with screw-less connections**
**SAKR L STB 6**
**SAKR LL**
**1.5 mm²**
**B** a
## **with solder connection TS 32 / PA**
## **4 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [503 x 563] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|6.5 x 50 x 40.5|6.5 x 58 x 40.5|
|max. current / max. cond. cross-section|A/mm²|10 / 4|10 / 1.5|
|Max. clamping range|mm²|0.5...4|0.5...1.5|
|Technical data|IEC 60947-7-1 / IEC 60068-2-20|IEC 60947-7-1 / IEC 60068-2-20|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|250|250|300|
|Rated current|A|10|10|10|
|Rated cross-section|mm²|4|1.5|AWG 22...12|
|Rated impulse voltage / Pollution severity|kV/-|4 / 3|4 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|/ V2|
|Approvals|#|r #|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...4 / 1.5...4|0.5...1.5|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...2.5|0.5...1.5|
|Tightening torque range (clamping screw)|0.5...1.0 Nm (M 3)|
|Stripping length / Blade size|mm/-|8 / 0.6 x 3.5 mm|
|Note|When using disconnect terminals with sockets, the tightening torque is|
|0.5 -0.7 Nm.|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|beige|SAKR LS 2STB|100|0518160000|SAKR LL|100|0464460000|
|right|
|left|
|Note|
|Accessories|
|Screwable cross-connection|Type|Qty.|Order No.|Type|Qty.|Order No.|
|2-pole|
|3-pole|
|4-pole|
|10-pole|
|External cross-connection|current|
|2-pole|QB 2 WI RA6 IS|27 A|50|0482700000|
|3-pole|QB 3 WI RA6 IS|27 A|50|0482800000|
|4-pole|QB 4 WI RA6 IS|27 A|50|0482900000|
|End plate / Partition plate|Width|Width|
|beige|AP SAKR BE|1.5 mm|20|0211360000|AP SAKR BE|1.5 mm|20|0211360000|
|Blue|AP SAKR BL|1.5 mm|20|0211380000|AP SAKR BL|1.5 mm|20|0211380000|
|beige|TW SAKS2 HP/DBR/2|2 mm|20|0607000000|TW SAKS2 HP/DBR/2|2 mm|20|0607000000|
|Blue|
|Small partition|
|Small partition|
|Cover / warning label|
|Cover / warning label|
|Mounting screw (plastic)|
|Testing / Checking|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 6/D3.7/2.3/M3 SAKR|100|0379400000|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/6,5|DEK 5/6,5|
|For detailed information on other accessories and ap-|QB 25 blank, refer to „Accessories“ section. Note that max. conductor connec-|
|plications, refer to the „Accessories“ section|tion with QB = 2.5 mm². Twin wire-end ferrules ZH 0.5 - ZH 1.5 can be used.|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
## **Accessories**
**B.40**
**Terminals with screw-less connections**
**SAKR LL mit STB 6**
**B**
## **1.5 mm²**
6.5 x 58 x 40.5 **10 / 1.5 0.33...1.5**
|IEC 60947-7-1 / IEC 60068-2-20|IEC 60947-7-1 / IEC 60068-2-20|IEC 60947-7-1 / IEC 60068-2-20|IEC 60947-7-1 / IEC 60068-2-20|
|---|---|---|---|
||**IEC**||**UL**<br>**CSA**|
||250||300|
||10||10|
||1.5||AWG 22...12|
||||4 / 3|
||||/ V2|
r # **Rated connection** 0.5...1.5
0.5...1.5 / 0.6 x 3.5 mm Tightening torque via the socket is 0.5 - 0.7 Nm.
|**Type**|**Qty.**<br>**Order No.**|
|---|---|
|SAKR LL 2STB|100<br>**0294260000**|
|||
|||
|||
|||
|**Type**|**Qty.**<br>**Order No.**|
|||
|||
|||
|||
|||
|||
|||
|||
||**Width**|
|AP SAKR BE|1.5 mm<br>20<br>**0211360000**|
|AP SAKR BL|1.5 mm<br>20<br>**0211380000**|
|TW AST1/PA HP/DBR/0.5|0.5 mm<br>20<br>**0474700000**|
|||
|||
|||
|||
|||
|||
|||
|PS 2.3 RT|5.4 mm<br>20<br>**0180400000**|
DEK 5/6,5
**B.41**
**Terminals with screw-less connections**
**AST 1**
**AST 3**
**2.5 mm²**
**B** »
## **with push-on connection TS 32 / KrG**
## **2.5 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
|technical appendix must be followed.<br>Width/Length/height with TS32x7.5<br>max. current / max. cond. cross-section<br>Max. clamping range|mm<br>A/mm²<br>mm²|6.5 x 58 x 46<br>**20 / 2.5**<br>**0.5...2.5**|6.5 x 58 x 46<br>**20 / 2.5**<br>**0.5...2.5**|2,8<br>2,8<br>2,8<br>2,8<br>6,3<br>6,3<br>6,3<br>6,3<br>Ly ~~3 yy~~|2,8<br>2,8<br>2,8<br>2,8<br>6,3<br>6,3<br>6,3<br>6,3<br>Ly ~~3 yy~~|2,8<br>2,8<br>2,8<br>2,8<br>6,3<br>6,3<br>6,3<br>6,3<br>Ly ~~3 yy~~|2,8<br>2,8<br>2,8<br>2,8<br>6,3<br>6,3<br>6,3<br>6,3<br>Ly ~~3 yy~~|2,8<br>2,8<br>2,8<br>2,8<br>6,3<br>6,3<br>6,3<br>6,3<br>Ly ~~3 yy~~|2,8<br>2,8<br>2,8<br>2,8<br>6,3<br>6,3<br>6,3<br>6,3<br>Ly ~~3 yy~~|2,8<br>2,8<br>2,8<br>2,8<br>6,3<br>6,3<br>6,3<br>6,3<br>Ly ~~3 yy~~||6.5 x 40 x 46<br>**20 / 2.5**<br>**0.5...2.5**|6,3<br>6,3<br>2,8<br>2,8<br>L~~ey~~|6,3<br>6,3<br>2,8<br>2,8<br>L~~ey~~|6,3<br>6,3<br>2,8<br>2,8<br>L~~ey~~|6,3<br>6,3<br>2,8<br>2,8<br>L~~ey~~|6,3<br>6,3<br>2,8<br>2,8<br>L~~ey~~|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Technical data**||IEC 60947-7-1 / IEC 61210||||||||||IEC 60947-7-1 / IEC 61210|IEC 60947-7-1 / IEC 61210|||||
|**Rated data**||**IEC**|**UL**|||**CSA**||||||**IEC**|**UL**|**CSA**||||
|Rated voltage|V|500|600|||300||||||500|300|300||||
|Rated current|A|20|13|||16||||||20|13|16||||
|Rated cross-section|mm²|2.5||||||||||2.5||||||
|Rated impulse voltage / Pollution severity|kV/-|||6 / 3|6 / 3||||||||6 / 3|||||
|Gauge to IEC 60947-1 / UL94 Flammabilityclass|||/ 5VA|/ 5VA|||||||||/ 5VA|||||
|Approvals|r u# a|||||||||||r# a||||||
|**Clamped conductors(H05V/H07V)**||**Rated connection**||||||||||**Rated connection**||||||
|solid / stranded|mm²|||||||||||||||||
|flexible / Stranded wire with end ferrules|mm²|0.5...2.5||||||||||0.5...2.5||||||
|Tighteningtorque range(clampingscrew)||||||||||||||||||
|Strippinglength / Blade size|mm/-|||||||||||||||||
|**Note**||Cable-lug connections should be fitted with insulating sleeves. 20 A with||Cable-lug connections should be fitted with insulating sleeves. 20 A with|||Cable-lug connections should be fitted with insulating sleeves. 20 A with||Cable-lug connections should be fitted with insulating sleeves. 20 A with|||The rated voltage is 800 V when using a cable-lug (flat) connector with IH|The rated voltage is 800 V when using a cable-lug (flat) connector with IH|||||
|||F 6.3 or 2 x F 2.8||||||||||6.3 insulating sleeves.||||||
## **Technical data**
## **Ordering data**
|**Version**||**Type**|**Qty.**|**Order No.**||**Type**|**Qty.**|**Order No.**|
|---|---|---|---|---|---|---|---|---|
|Slotted||AST 1 6.3/2.8 KRG|50|**0478220000**||AST 3 6.3/2.8 KRG|100|**0442420000**|
|Not slit||AST 1 6.3 KRG|50|**0266320000**||AST 3 6.3 KRG|100|**0298020000**|
|**Note**||||||Cable-lug connections should be connected with insulating sleeves. 20 A|Cable-lug connections should be connected with insulating sleeves. 20 A||
|||||||with F 6.3 or 2 x F 2.8|||
|**Accessories**|||||||||
|**Screwable cross-connection**||**Type**|**current**<br>**Qty.**|**Order No.**||**Type**|**current**<br>**Qty.**|**Order No.**|
|2-pole||Q 2 SAK4|41 A<br>50|**0336700000**||Q 2 SAK4|41 A<br>50|**0336700000**|
|3-pole||Q 3 SAK4|41 A<br>50|**0336800000**||Q 3 SAK4|41 A<br>50|**0336800000**|
|4-pole||Q 4 SAK4|41 A<br>50|**0336900000**||Q 4 SAK4|41 A<br>50|**0336900000**|
|10-pole||Q 10 SAK4|41 A<br>20|**0368800000**||Q 10 SAK4|41 A<br>20|**0368800000**|
|**Plug-in adapter**|||**Width**||||||
|2-pole||STA 2.5/2|100|**0165860000**|||||
|3-pole||STA 2.5/3|50|**0165960000**|||||
|4-pole||STA 2.5/4|50|**0190360000**|||||
|5-pole||STA 2.5/5|50|**0166060000**|||||
|8-pole||STA 2.5/8|50|**0166160000**|||||
|**Endplate / Partitionplate**|||||||**Width**||
|beige|||||||||
|Mediumyellow||AP AST1+5 KRG|3 mm<br>20|**0266420000**||AP AST3+4 KRG|3 mm<br>20|**0298120000**|
|Blue|||||||||
|beige||TW SAKS2 HP/DBR/2|2 mm<br>20|**0607000000**||TW SAKS2 HP/DBR/2|2 mm<br>20|**0607000000**|
|Mediumyellow|||||||||
|Blue|||||||||
|**Smallpartition**|||||||||
|Smallpartition||TSCH 1|2 mm<br>100|**0319160000**||TSCH 1|2 mm<br>100|**0319160000**|
|**Testing / Checking**|||||||||
|Testplug||PS 2.3 RT|5.4 mm<br>20|**0180400000**||PS 2.3 RT|5.4 mm<br>20|**0180400000**|
|Socket||STB 14/D5/2.3/M3 SAK2.5|50|**0168600000**||STB 14/D5/2.3/M3 SAK2.5|50|**0168600000**|
|**Insulating sleeve**|||||||||
|2,8||IH 2.8 DB|100|**0386060000**||IH 2.8 DB|100|**0386060000**|
|6,3||IH 6.3 WEM GE|100|**0386260000**||IH 6.3 WEM GE|100|**0386260000**|
|**Marking systems**<br>(see assortment in catalogue 7)|||||||||
|Marking tags||DEK 5/6,5||||DEK 5/6|||
|**For detailed information on other accessories and ap-**|||||||||
|**plications, refer to the „Accessories“ section**|||||||||
## **Accessories**
**B.42**
**Terminals with screw-less connections**
**AST 4**
**2.5 mm² AST 5**
## **4 mm²**
|6.2 x 40 x 46|6.2 x 40 x 46||||||6,3<br>6.5 x 58 x 46|6,3<br>6.5 x 58 x 46|||6,3||6,3<br>6,3|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**20 / 4**|||||||2,8<br>**20 / 6**||||2,8||2,8<br>2,8|
|**0.2...4**|||||||**0.2...6**|||||||
|IEC 60947-7-1 / IEC 61210|||||||IEC 60947-7-1 / IEC 61210|||||||
|**IEC**|**UL**|||**CSA**|||**IEC**|**UL**||**CSA**||||
|500|300|||300|||500|300||300||||
|20|13|||16|||20|13||16||||
|2.5|AWG 22...12|||AWG 24...12|AWG 24...12||4|AWG 22...12||AWG 24...12|AWG 24...12|||
||6 / 3||6 / 3|||||6 / 3|6 / 3|||||
||A3 / 5VA||A3 / 5VA|A3 / 5VA||||A4 / 5VA|A4 / 5VA|A4 / 5VA||||
|r# a|||||||r u# a|||||||
|**Rated connection**|||||||**Rated connection**|||||||
|0.5...4 / 1.5...2.5|||||||0.5...6 / 1.5...2.5|||||||
|0.5...2.5 / 0.5...2.5|||||||0.5...4 / 0.5...4|||||||
|0.4...0.7 Nm(M 2.5|M 2.5)||||||0.5...1.0 Nm(M 3|M 3)||||||
|9 / 0.6 x 3.5 mm|||||||12 / 0.6 x 3.5 mm|||||||
|Cable-lug connections should be fitted with insulating sleeves. 20 A with F<br>Cable-lug connections should be fitted with insulating sleeves. 20 A with||||||||||||||
|6.3 or 2 x F 2.8 When used with F 2.8, the rated voltage is 500 V||6.3 or 2 x F 2.8 When used with F 2.8, the rated voltage is 500 V<br>F 6.3 or 2 x F 2.8||||||||||||
|||||||||||||||
|**Type**|||||**Qty.**||**Order No.**<br>**Type**||||**Qty.**||**Order No.**|
|AST 4 SF 6.3/2.8 KRG|||||100||**0439120000**<br>AST 5 SF 6.3/2.8 KRG||||50||**0479220000**|
||||||||AST 5 SF 6.3 KRG||||50||**0334520000**|
|||||||||||||||
|||||||||||||||
|**Type**|**current**||||**Qty.**||**Order No.**<br>**Type**|**current**|||**Qty.**||**Order No.**|
|Q 2 SAK4||||41 A|50||**0336700000**<br>Q 2 SAK4|||41 A|50||**0336700000**|
|Q 3 SAK4||||41 A|50||**0336800000**<br>Q 3 SAK4|||41 A|50||**0336800000**|
|Q 4 SAK4||||41 A|50||**0336900000**<br>Q 4 SAK4|||41 A|50||**0336900000**|
|Q 10 SAK4||||41 A|20||**0368800000**<br>Q 10 SAK4|||41 A|20||**0368800000**|
||||**Width**|||||||||||
|STA 2.5/2|||||100||**0165860000**|||||||
|STA 2.5/3|||||50||**0165960000**|||||||
|STA 2.5/4|||||50||**0190360000**|||||||
|STA 2.5/5|||||50||**0166060000**|||||||
|STA 2.5/8|||||50||**0166160000**|||||||
||||||||||**Width**|||||
|||||||||||||||
|AP AST3+4 KRG||||3 mm|20||**0298120000**<br>AP AST1+5 KRG|||3 mm|20||**0266420000**|
|||||||||||||||
|TW SAKS2 HP/DBR/2||||2 mm|20||**0607000000**<br>TW SAKS2 HP/DBR/2|||2 mm|20||**0607000000**|
|||||||||||||||
|||||||||||||||
|||||||||||||||
|TSCH 1||||2 mm|100||**0319160000**<br>TSCH 1|||2 mm|100||**0319160000**|
|||||||||||||||
|PS 2.3 RT|5.4 mm||||20||**0180400000**<br>PS 2.3 RT|5.4 mm|||20||**0180400000**|
|STB 14/D5/2.3/M3 SAK2.5|||||50||**0168600000**<br>STB 14/D5/2.3/M3 SAK2.5||||50||**0168600000**|
|||||||||||||||
|IH 2.8 DB|||||100||**0386060000**<br>IH 2.8 DB||||100||**0386060000**|
|IH 6.3 WEM GE|||||100||**0386260000**<br>IH 6.3 WEM GE||||100||**0386260000**|
|DEK 5/6|||||||DEK 5/6,5|||||||
**B**
**B.43**
**Terminals with screw-less connections**
**SAK 4 S**
**SAK 4 SS**
**2.5 mm²**
**B**
## **with push-on connection TS 32 / KrG**
## **4 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
## **Technical data**
**==> picture [159 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Rated data|
|Rated voltage|V|
|Rated current|A|
|Rated cross-section|mm²|
|Rated impulse voltage / Pollution severity|kV/-|
|Gauge to IEC 60947-1 / UL94 Flammability class|
|Approvals|
|Clamped conductors (H05V/H07V)|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|Note|
**----- End of picture text -----**<br>
**==> picture [334 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|6.5 x 40 x 51.5|6,3|6.5 x 40 x 51.5|6,3|6,3|
|20 / 6|2,8|20 / 2.5|2,8|2,8|
|6,3|6,3|6,3|
|0.13...6|2,8|0.5...2.5|2,8|2,8|
|IEC 60947-7-1 / IEC 61210|IEC 60947-7-1 / IEC 61210|
|IEC|UL|CSA|IEC|UL|CSA|
|500|300|300|500|600|300|
|20|13|13|20|13|13|
|4|AWG 26...12|AWG 26...12|2.5|AWG 18...14|AWG 18...14|
|6 / 3|6 / 3|
|A4 / 5VA|/ 5VA|
|r|u # a|?|r|u # a|
|Rated connection|Rated connection|
|0.33...6 / 1.5...4|
|0.5...4 / 0.5...4|0.5...2.5|
|0.5...1.0 Nm (M 3)|
|12 / 0.6 x 3.5 mm|
|Cable-lug connections should be fitted with insulating sleeves. 20 A with|Cable-lug connections should be fitted with insulating sleeves. 20 A with|
|F 6.3 or 2 x F 2.8|F 6.3 or 2 x F 2.8|
**----- End of picture text -----**<br>
## **Ordering data**
**==> picture [503 x 364] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Slotted|SAK 4 S 6.3/2.8/KRG|100|0401220000|SAK 4 SS 6.3/2.8 KRG|100|0479620000|
|Not slit|SAK 4 SS 6.3/KRG|100|0352920000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAK4|32 A|100|0130600000|QL 2 SAK4|32 A|100|0130600000|
|3-pole|QL 3 SAK4|32 A|100|0130700000|QL 3 SAK4|32 A|100|0130700000|
|4-pole|QL 4 SAK4|32 A|50|0130800000|QL 4 SAK4|32 A|50|0130800000|
|10-pole|QL 10 SAK4|32 A|20|0338200000|QL 10 SAK4|32 A|20|0338200000|
|Plug-in adapter|
|2-pole|
|3-pole|
|4-pole|
|5-pole|
|8-pole|
|End plate / Partition plate|Width|Width|
|beige|AP SAK4-10|1.5 mm|20|0117960000|
|Medium yellow|AP SAK4-10 KRG|1.5 mm|20|0117920000|
|Blue|AP SAK4-10 KRG/BL|1.5 mm|20|0117970000|
|beige|TW 4 SAK4-10|1.5 mm|20|0130160000|
|Medium yellow|TW SAK4-10 KRG|2.5 mm|20|0130120000|
|Blue|TW SAK4-10 KRG/BL|2.5 mm|20|0130170000|
|Small partition|
|Small partition|
|Testing / Checking|
|Test plug|
|Socket|
|Insulating sleeve|
|2,8|IH 2.8 DB|100|0386060000|IH 2.8 DB|100|0386060000|
|6,3|IH 6.3 WEM GE|100|0386260000|IH 6.3 WEM GE|100|0386260000|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/6,5|DEK 5/6,5|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
## **Accessories**
**B.44**
**Terminals with screw-less connections**
**SAK 2.5 L**
**B** L
## **with solder connection TS 32 / KrG**
## **2.5 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
## **Technical data**
6 x 44.5 x 46.5 **17.5 / 6 0.33...6**
## IEC 60947-7-1 / IEC 60068-2-20
**==> picture [291 x 116] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Rated data|IEC|UL|CSA|
|Rated voltage|V|250|300|
|Rated current|A|17.5|10|
|Rated cross-section|mm²|2.5|AWG 22...12|
|Rated impulse voltage / Pollution severity|kV/-|4 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / 5VA|
|Approvals|r|
|Clamped conductors (H05V/H07V)|Rated connection|
|solid / stranded|mm²|0.5...6 / 0.5...2.5|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...2.5|
|Tightening torque range (clamping screw)|0.4...0.7 Nm (M 2.5)|
|Stripping length / Blade size|mm/-|10 / 0.6 x 3.5 mm|
|Note|max 1.5 mm² conductor via solder connection|
**----- End of picture text -----**<br>
## **Ordering data**
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|SAK 2.5 LS KRG|100|0544120000|
**----- End of picture text -----**<br>
**Version Note**
**==> picture [335 x 211] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Medium yellow|SAK 2.5 LS KRG|100|0544120000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|
|2-pole|Q 2 SAK2.5|41 A|50|0337000000|
|3-pole|Q 3 SAK2.5|41 A|50|0337100000|
|4-pole|Q 4 SAK2.5|41 A|50|0337200000|
|TT|10-pole|_|Q 10 SAK2.5|Oe|41 A|20|0368700000|
|Testing / Checking|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/5/2.3/M3 SAK2.5|50|0280600000|
|End plate|
|Medium yellow|AP SAK2.5L KRG|1.5 mm|20|0309220000|
|Blue|AP SAK2.5L KRG BL|1.5 mm|20|0309270000|
|End plate / Partition plate|
|beige|TW SAKS2 HP/DBR/2|2 mm|20|0607000000|
|Small partition|
|Small partition|TSCH 1|2 mm|100|0319160000|
|Cover / warning label|
|Cover / warning label|AD 4 AKZ4|50|0303400000|
|Mounting screw (plastic)|BFSC M3X22 PA/RT|100|0128900000|
**----- End of picture text -----**<br>
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/6 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
**B.45**
**Special terminals - SAKG**
**B** -
## **SAKG 28 I 35 mm²**
## **TS 32 / KrG**
28 x 70 x 63.5 **150 / 50** ‘es **6...50**
The Weidmüller SAKG range offers the following connection variants:
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
- Clamping yoke/flat lug as a combination, Version I.
- Flat lug, Version II. Two types of threading are provided here. a) screw set with lock nut
Width/Length/height with TS32x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
- b) with thread in busbar
## **Technical data**
- Clamping yoke connection, Version III. The stripped conductor can be connected without further preparation.
|**Technical data**|||||
|---|---|---|---|---|
|**Technical data**||IEC 60947-7-1|||
|**Rated data**||**IEC**|**UL**|**CSA**|
|Rated voltage|V|1000|600|600|
|Rated current|A|125|95|110|
|Rated cross-section|mm²|35|AWG 6...2|AWG 6...1|
|Rated impulse voltage / Pollution severity|kV/-||8 / 3||
|Gauge to IEC 60947-1 / UL94 Flammabilityclass|||B9 / 5VA|B9 / 5VA|
|Approvals||? r u# a|||
|**Clamped conductors(H05V/H07V)**||**Rated connection**|||
|solid / stranded<br>flexible / Stranded wire with end ferrules<br>Tighteningtorque range(clampingscrew)<br>Strippinglength / Blade size|mm²<br>mm²<br>mm/-|6...16 / 6...50<br>10...35 / 6...35<br>4.0...6.0 Nm(M 6<br>15 /|M 6)||
|**Note**||Conductor connection with cable lugs according to DIN 46234 and DIN||Conductor connection with cable lugs according to DIN 46234 and DIN|
## **Versions**
**Rated connection** 6...16 / 6...50 10...35 / 6...35 4.0...6.0 Nm (M 6) 15 / Conductor connection with cable lugs according to DIN 46234 and DIN 46235, from 6 .. 50 mm²
**==> picture [138 x 85] intentionally omitted <==**
**----- Start of picture text -----**<br>
Version I Version II<br>without thread<br>—<br>Version IIG Version III<br>with thread<br>**----- End of picture text -----**<br>
**Ordering data Version Type Qty. Order No.** ~~——————————~~ — Medium yellow SAKG 28 I 10 **0170020000 Version IIG Note**
Cables with cable lugs are connected to SAKG terminals of Version I and to SS stud terminals.
## **Accessories**
|**Screwable cross-connection**||**Type**|**current**|**Qty.**|**Order No.**|
|---|---|---|---|---|---|
|2-pole||QL 2 SAKG28||10|**0551200000**|
|3-pole||QL 3 SAKG28||5|**0407600000**|
|4-pole<br>**Endplate**<br>dark brown<br>Tropical applications<br>**Endplate / Partitionplate**||QL 4 SAKG28<br>**Width**<br>EP 1 SAKG28/32 HP/DBR<br>2 mm<br>EP 1 SAKG28/32 HP/TF/GE<br>2 mm||5<br>10<br>10|**0407700000**<br>**0205100000**<br>**0205200000**|
|dark brown||TW SAKG28 HP/DBR/2|2 mm|10|**0151400000**|
|Tropical applications||TW SAKG28 HP/TF/GE/2|2 mm|10|**0164600000**|
|**Cover / warning label**||||||
|Cover / warninglabel||AH 28 SAKG28|26 mm|5|**0326660000**|
## **Fitting instructions for SAKG terminals**
When tightening the clamping screw, it is recommended that the conductor be held against the direction of tightening to prevent deformation of the mounting rail and so as not to place the terminal foot under undue torsional forces.
## **Cover**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
To ensure shock protection following connections of **conductors, AH** covers can be clipped onto the terminal.
**B.46**
**Special terminals - SAKG**
**SAKG 28 II**
**SAKG 28 II G**
**B**
## **TS 32 / KrG**
**35 mm²**
**35 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [462 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|28 x 70 x 53|28 x 70 x 51.4|
|max. current / max. cond. cross-section|A/mm²|150 / 50|150 / 50|
|Max. clamping range|mm²|6...50|6...50|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|1000|600|600|1000|600|600|
|Rated current|A|125|115|110|125|95|110|
|Rated cross-section|mm²|35|AWG 8...2|AWG 6...1|35|AWG 8...2|AWG 6...1|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 /|
|Gauge to IEC 60947-1 / UL94 Flammability class|/ 5VA|/ 5VA|
|Approvals|?|r|u # a|?|r|u #|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Tightening torque range (clamping screw)|3.0...6.0 Nm (M 6)|3.0...6.0 Nm (M 6)|
|Stripping length / Blade size|mm/-|
|Note|Conductor connection with cable lugs according to DIN 46234 and DIN|
|46235, from 6 .. 50 mm²|46235, from 6 .. 50 mm²|
**----- End of picture text -----**<br>
## **Technical data**
**==> picture [504 x 220] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Note|Conductor connection with cable lugs according to DIN 46234 and DIN|Conductor connection with cable lugs according to DIN 46234 and DIN|
|46235, from 6 .. 50 mm²|46235, from 6 .. 50 mm²|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Medium yellow|SAKG 28 II|10|0170320000|SAKG 28 II/GW|10|0185020000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAKG28|125 A|10|0551200000|QL 2 SAKG28|125 A|10|0551200000|
|3-pole|QL 3 SAKG28|232 A|5|0407600000|QL 3 SAKG28|232 A|5|0407600000|
|4-pole|QL 4 SAKG28|125 A|5|0407700000|QL 4 SAKG28|125 A|5|0407700000|
|End plate|Width|Width|
|dark brown|EP 1 SAKG28/32 HP/DBR|2 mm|10|0205100000|EP 1 SAKG28/32 HP/DBR|2 mm|10|0205100000|
|Tropical applications|EP 1 SAKG28/32 HP/TF/GE|2 mm|10|0205200000|EP 1 SAKG28/32 HP/TF/GE|2 mm|10|0205200000|
|End plate / Partition plate|
|dark brown|
|Tropical applications|
|dark brown|TW SAKG28 HP/DBR/2|2 mm|10|0151400000|TW SAKG28 HP/DBR/2|2 mm|10|0151400000|
|Tropical applications|TW SAKG28 HP/TF/GE/2|2 mm|10|0164600000|TW SAKG28 HP/TF/GE/2|2 mm|10|0164600000|
|Cover / warning label|
|Cover / warning label|AH 28 SAKG28|26 mm|5|0326660000|AH 28 SAKG28|26 mm|5|0326660000|
**----- End of picture text -----**<br>
## **Ordering datag data data**
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
**B.47**
**Special terminals - SAKG**
**SAKG 28 III**
**SAKG 32 I**
**35 mm²**
**50 mm²**
**B** Zz
## **TS 32 / KrG**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS32x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
**==> picture [503 x 382] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|28 x 70 x 63.5|32 x 87.3 x 84|
|max. current / max. cond. cross-section|A/mm²|150 / 50|192 / 70|
|Max. clamping range|mm²|6...50|10...70|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|1000|600|600|1000|600|600|
|Rated current|A|125|95|135|150|165|170|
|Rated cross-section|mm²|35|AWG 8...2|AWG 8...2|50|AWG 6...3/0|AWG 1...2/0|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|B9 / 5VA|B11 / 5VA|
|Approvals|r|u # a|?|r|u # a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|6...16 / 6...50|10...16 / 10...70|
|flexible / Stranded wire with end ferrules|mm²|10...35 / 6...35|10...70 / 10...70|
|Tightening torque range (clamping screw)|4.0...6.0 Nm (M 6)|6.0...12 Nm (M 8)|
|Stripping length / Blade size|mm/-|15 /|26 /|
|Note|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Medium yellow|SAKG 28 III|10|0170820000|SAKG 32 I|10|0286620000|
|Note|
|Accessories|
|Screwable cross-connection|Type|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAKG32+70|150 A|5|0194000000|
|3-pole|QL 3 SAKG32+70|150 A|5|0441500000|
|4-pole|QL 4 SAKG32+70|150 A|5|0441600000|
|End plate|Width|Width|
|dark brown|EP 1 SAKG28/32 HP/DBR|2 mm|10|0205100000|EP 2 SAKG46/32 HP/DBR|2 mm|10|0205300000|
|Tropical applications|EP 1 SAKG28/32 HP/TF/GE|2 mm|10|0205200000|EP 2 SAKG46/32 HP/TF/GE|2 mm|10|0205400000|
|End plate / Partition plate|
|dark brown|
|Tropical applications|
|dark brown|TW SAKG28 HP/DBR/2|2 mm|10|0151400000|TW SAKG46 HP/DBR/2|2 mm|10|0177100000|
|Tropical applications|TW SAKG28 HP/TF/GE/2|2 mm|10|0164600000|TW SAKG46 HP/TF/GE/2|2 mm|10|0179900000|
|Cover / warning label|
|Cover / warning label|AH 28 SAKG28|26 mm|5|0326660000|AH 32 SAKG32|30 mm|5|0326760000|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
**B.48**
**Special terminals - SAKG**
**SAKG 32 II**
**50 mm² SAKG 32 II G**
**SAKG 32 III**
**B**
**==> picture [33 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
50 mm²<br>**----- End of picture text -----**<br>
**50 mm²**
|32 x 80 x 53<br>**192 / 70**|32 x 80 x 53<br>**192 / 70**|o————_o|o————_o|32 x 80 x 53<br>**192 / 70**<br>o————_o|32 x 80 x 53<br>**192 / 70**<br>o————_o|o————_o|o————_o|o————_o||32 x 94 x 84.5<br>**192 / 70**|32 x 94 x 84.5<br>**192 / 70**|32 x 94 x 84.5<br>**192 / 70**|o—————_o|o—————_o|o—————_o|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||o————_o|o————_o|o————_o||o————_o|o————_o|o————_o|||||o—————_o|o—————_o|o—————_o|
|**10...70**||||**10...70**||||||**10...70**||||||
|IEC 60947-7-1||||IEC 60947-7-1||||||IEC 60947-7-1|IEC 60947-7-1|||||
|**IEC**|**UL**|**CSA**||**IEC**||**UL**<br>**CSA**|||||**IEC**|**UL**|**CSA**|||
|1000|600||600|1000|||600||||1000|600||600||
|150|200||170|150|||170||||150|165||185||
|50|AWG 6...3/0|AWG 1...2/0||50||AWG 1...2/0|||||50|AWG 6...3/0|AWG 1...2/0|||
||8 / 3|||||8 / 3||||||8 / 3||||
||/ 5VA|/ 5VA||||/ 5VA||||||B11 / 5VA||||
|? r u# a||||? r u#||||||r u# a||||||
|**Rated connection**||||**Rated connection**||||||**Rated connection**||||||
|||||||||||10...16 / 10...70||||||
|||||||||||10...70 / 10...70||||||
|6.0...12 Nm(M 8)||||6.0...12 Nm(M 8)||||||6.0...12 Nm(M 8)||||||
|||||||||||26 /|26 /|||||
|Conductor connection with cable lugs according to DIN 46234 and DIN||||Conductor connection with cable lugs according to DIN 46234 and DIN<br>Conductor connection with cable lugs according to DIN 46234 and DIN||||Conductor connection with cable lugs according to DIN 46234 and DIN||||||||
|46235, from 10 .. 70 mm²|46235, from 10 .. 70 mm²|||46235, from 10 .. 70 mm²|46235, from 10 .. 70 mm²|||||||||||
|||||||||||||||||
|**Type**|||**Qty.**|**Order No.**<br>**Type**|||**Qty.**|**Order No.**||**Type**||||**Qty.**|**Order No.**|
|SAKG 32 II|||10|**0170420000**<br>SAKG 32 II/GW|||10|**0185120000**||SAKG 32 III||||10|**0286720000**|
|||||||||||||||||
|||||||||||||||||
|**Type**|**current**||**Qty.**|**Order No.**<br>**Type**||**current**|**Qty.**|**Order No.**||**Type**||||**Qty.**|**Order No.**|
|QL 2 SAKG32+70||150 A|5|**0194000000**<br>QL 2 SAKG32+70||150 A|5|**0194000000**||||||||
|QL 3 SAKG32+70||150 A|5|**0441500000**<br>QL 3 SAKG32+70||150 A|5|**0441500000**||||||||
|QL 4 SAKG32+70||150 A|5|**0441600000**<br>QL 4 SAKG32+70||150 A|5|**0441600000**||||||||
|||**Width**|||||||||||**Width**|||
|EP 1 SAKG28/32 HP/DBR||2 mm|10|**0205100000**||||||EP 2 SAKG46/32 HP/DBR|||2 mm|10|**0205300000**|
|EP 1 SAKG28/32 HP/TF/GE||2 mm|10|**0205200000**||||||EP 2 SAKG46/32 HP/TF/GE|||2 mm|10|**0205400000**|
|||||||**Width**||||||||||
|||||EP 1 SAKG32/35 HP/DBR<br>2 mm|||10|**0180500000**||||||||
|||||EP 1 SAKG32/35 HP/TF/GE<br>2 mm|||10|**0180600000**||||||||
|TW SAKG46 HP/DBR/2||2 mm|10|**0177100000**<br>TW SAKG28 HP/DBR/2<br>2 mm|||10|**0151400000**||TW SAKG46 HP/DBR/2|TW SAKG46 HP/DBR/2||2 mm|10|**0177100000**|
|TW SAKG46 HP/TF/GE/2||2 mm|10|**0179900000**<br>TW SAKG28 HP/TF/GE/2<br>2 mm|||10|**0164600000**||TW SAKG46 HP/TF/GE/2|TW SAKG46 HP/TF/GE/2||2 mm|10|**0179900000**|
|||||||||||||||||
|AH 32 SAKG32||30 mm|5|**0326760000**<br>AH 32 SAKG32||30 mm|5|**0326760000**||AH 32 SAKG32|||30 mm|5|**0326760000**|
DEK 5/5
DEK 5/5
DEK 5/5
**B.49**
**Special terminals - SAKG**
**SAKG 70 II G**
**SAKG 40 I**
**70 mm²**
**95 mm²**
**B**
## **TS 32 / KrG**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [502 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|32 x 84 x 51.4|40 x 94 x 84.5|
|max. current / max. cond. cross-section|A/mm²|192 / 95|232 / 95|
|Max. clamping range|mm²|10...95|10...95|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|1000|600|1000|600|600|
|Rated current|A|192|200|232|195|250|
|Rated cross-section|mm²|70|AWG 6...3/0|AWG 2/0...4/0|95|AWG 2/0...4/0|AWG 2/0...4/0|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|/ 5VA|B12 / 5VA|
|Approvals|r|u #|?|r|u # a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|10...16|10...16 / 10...95|
|flexible / Stranded wire with end ferrules|mm²|10...95 / 10...95|
|Tightening torque range (clamping screw)|6.0...12 Nm (M 8)|10...20 Nm (M 10)|
|Stripping length / Blade size|mm/-|25 /|
|Note|Conductor connection with cable lugs according to DIN 46234 with|Conductor connection with cable lugs acc. to DIN 46234 from 10 .. 95|
|16..95 mm² and DIN 46235 with 10 .. 50 mm²|mm²|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering data**
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|SAKG 70 II/GW|10|0150420000|
**----- End of picture text -----**<br>
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|SAKG 40 I|10|0286820000|
**----- End of picture text -----**<br>
**Version Note**
**==> picture [503 x 174] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Medium yellow|SAKG 70 II/GW|10|0150420000|SAKG 40 I|10|0286820000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAKG32+70|150 A|5|0194000000|QL 2 SAKG40|232 A|5|0194100000|
|3-pole|QL 3 SAKG32+70|150 A|5|0441500000|QL 3 SAKG40|232 A|5|0263500000|
|4-pole|QL 4 SAKG32+70|150 A|5|0441600000|QL 4 SAKG40|232 A|5|0409800000|
|End plate|Width|Width|
|dark brown|EP 1 SAKG28/32 HP/DBR|2 mm|10|0205100000|EP 2 SAKG46/32 HP/DBR|2 mm|10|0205300000|
|Tropical applications|EP 1 SAKG28/32 HP/TF/GE|2 mm|10|0205200000|EP 2 SAKG46/32 HP/TF/GE|2 mm|10|0205400000|
|End plate / Partition plate|
|dark brown|
|Tropical applications|
|dark brown|TW SAKG28 HP/DBR/2|2 mm|10|0151400000|TW SAKG46 HP/DBR/2|2 mm|10|0177100000|
|Tropical applications|TW SAKG28 HP/TF/GE/2|2 mm|10|0164600000|TW SAKG46 HP/TF/GE/2|2 mm|10|0179900000|
|Cover / warning label|
|Cover / warning label|AH 32 SAKG32|30 mm|5|0326760000|AH 40 SAKG40|38 mm|5|0326860000|
**----- End of picture text -----**<br>
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
**B.50**
**Special terminals - SAKG**
**SAKG 40 II**
**95 mm² SAKG 40 II GW**
**SAKG 40 III**
**95 mm²**
**95 mm²**
**B** (os) a
|40 x 90 x 53<br>**232 / 95**<br>**10...95**|40 x 90 x 53<br>**232 / 95**<br>**10...95**|O09|O09|40 x 90 x 53<br>**232 / 95**<br>**10...95**<br>O09|40 x 90 x 53<br>**232 / 95**<br>**10...95**<br>O09|o————_o|o————_o|o————_o||40 x 98 x 84.5<br>**232 / 95**<br>**10...95**|40 x 98 x 84.5<br>**232 / 95**<br>**10...95**|(os)|(os)|(os)|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|IEC 60947-7-1||||IEC 60947-7-1||||||IEC 60947-7-1|||||
|**IEC**|**UL**|**CSA**||**IEC**|**UL**|**CSA**||||**IEC**|**UL**|**CSA**|||
|1000|600||600|1000|600||600|||1000|600||600||
|232|230||250|232|230||250|||232|195||230||
|95|AWG 1...4/0|AWG 2/0...4/0|AWG 2/0...4/0|95|AWG 1...4/0|AWG 2/0...4/0|AWG 2/0...4/0|||95|AWG 1...4/0|AWG 2/0...4/0|AWG 2/0...4/0||
||8 / 3||||8 / 3||||||8 / 3||||
||/ 5VA|/ 5VA|||/ 5VA|/ 5VA|||||B12 / 5VA||||
|? r u# a||||? r u#||||||r u# a|||||
|**Rated connection**||||**Rated connection**||||||**Rated connection**|||||
|...16||||...16||||||10...16 / 10...95|||||
|||||||||||10...95 / 10...95|||||
|10...20 Nm(M 10|M 10)|||10...20 Nm(M 10|M 10)|||||16...20 Nm(M 10|M 10)||||
|||||||||||25 /|||||
|Conductor connection with cable lugs according to DIN 46234, from 10||||Conductor connection with cable lugs according to DIN 46234, from 10<br>Conductor connection with cable lugs according to DIN 46234, from 10||||Conductor connection with cable lugs according to DIN 46234, from 10|||||||
|.. 95 mm²||||.. 95 mm²|||||||||||
||||||||||||||||
|**Type**|||**Qty.**|**Order No.**<br>**Type**|||**Qty.**|**Order No.**||**Type**|||**Qty.**|**Order No.**|
|SAKG 40 II|||10|**0170520000**<br>SAKG 40 II/GW|||10|**0185220000**||SAKG 40 III|||10|**0286920000**|
||||||||||||||||
||||||||||||||||
|**Type**|**current**||**Qty.**|**Order No.**<br>**Type**|**current**||**Qty.**|**Order No.**||**Type**|||**Qty.**|**Order No.**|
|QL 2 SAKG40||232 A|5|**0194100000**<br>QL 2 SAKG40||232 A|5|**0194100000**|||||||
|QL 3 SAKG40||232 A|5|**0263500000**<br>QL 3 SAKG40||232 A|5|**0263500000**|||||||
|QL 4 SAKG40||232 A|5|**0409800000**<br>QL 4 SAKG40||232 A|5|**0409800000**|||||||
|||**Width**||||**Width**||||||**Width**|||
|EP 2 SAKG46/32 HP/DBR||2 mm|10|**0205300000**<br>EP 2 SAKG46/32 HP/DBR||2 mm|10|**0205300000**||EP 2 SAKG46/32 HP/DBR||2 mm|10|**0205300000**|
|EP 2 SAKG46/32 HP/TF/GE||2 mm|10|**0205400000**<br>EP 2 SAKG46/32 HP/TF/GE||2 mm|10|**0205400000**||EP 2 SAKG46/32 HP/TF/GE||2 mm|10|**0205400000**|
||||||||||||||||
||||||||||||||||
||||||||||||||||
|TW SAKG46 HP/DBR/2||2 mm|10|**0177100000**<br>TW SAKG46 HP/DBR/2||2 mm|10|**0177100000**||TW SAKG46 HP/DBR/2||2 mm|10|**0177100000**|
|TW SAKG46 HP/TF/GE/2||2 mm|10|**0179900000**<br>TW SAKG46 HP/TF/GE/2||2 mm|10|**0179900000**||TW SAKG46 HP/TF/GE/2||2 mm|10|**0179900000**|
||||||||||||||||
|AH 40 SAKG40||38 mm|5|**0326860000**<br>AH 40 SAKG40||38 mm|5|**0326860000**||AH 40 SAKG40||38 mm|5|**0326860000**|
DEK 5/5
DEK 5/5
DEK 5/5
**B.51**
**Special terminals - SAKG**
**SAKG 46 II**
**SAKG 46 II GW**
**150 mm²**
**150 mm²**
**B**
## **TS 32 / KrG**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [509 x 382] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|46 x 106 x 57|46 x 106 x 57|
|max. current / max. cond. cross-section|A/mm²|353 / 185|353 / 185|
|Max. clamping range|mm²|10...185|10...185|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|1000|600|600|1000|600|600|
|Rated current|A|309|285|365|309|285|365|
|Rated cross-section|mm²|150|AWG 4/0...300|AWG 4...300|150|AWG 4/0...kcmil 300|AWG 1...300|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|/ 5VA|/ 5VA|
|Approvals|?|r|u # a|?|r|u #|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|10...16|10...16|
|flexible / Stranded wire with end ferrules|mm²|
|Tightening torque range (clamping screw)|14...31 Nm M 12|14...31 Nm M 12|
|Stripping length / Blade size|mm/-|
|Note|Conductor connection with cable lugs according to DIN 46234, from 10 ..|Conductor connection with cable lugs according to DIN 46234, from 10 ..|
|185 mm² and DIN 46235, from 25 .. 150 mm²|185 mm² and DIN 46235, from 25 .. 150 mm²|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Medium yellow|SAKG 46 II|5|0170620000|SAKG 46 II/GW|5|0185320000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAKG46|309 A|5|0247000000|QL 2 SAKG46|309 A|5|0247000000|
|3-pole|QL 3 SAKG46|309 A|5|0444400000|QL 3 SAKG46|309 A|5|0444400000|
|4-pole|QL 4 SAKG46|309 A|5|0444500000|QL 4 SAKG46|309 A|5|0444500000|
|End plate|Width|Width|
|dark brown|EP 2 SAKG46/32 HP/DBR|2 mm|10|0205300000|EP 2 SAKG46/32 HP/DBR|2 mm|10|0205300000|
|Tropical applications|EP 2 SAKG46/32 HP/TF/GE|2 mm|10|0205400000|EP 2 SAKG46/32 HP/TF/GE|2 mm|10|0205400000|
|End plate / Partition plate|
|dark brown|
|Tropical applications|
|dark brown|TW SAKG46 HP/DBR/2|2 mm|10|0177100000|TW SAKG46 HP/DBR/2|2 mm|10|0177100000|
|Tropical applications|TW SAKG46 HP/TF/GE/2|2 mm|10|0179900000|TW SAKG46 HP/TF/GE/2|2 mm|10|0179900000|
|Cover / warning label|
|Cover / warning label|AH 46 SAKG46|46 mm|5|0326960000|AH 46 SAKG46|46 mm|5|0326960000|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
**B.52**
**Special terminals - SAKG**
**240 mm² SAKG 54 II GW**
## **SAKG 54 II**
## **240 mm²**
|54 x 122 x 60.5|54 x 122 x 60.5|||54 x 122 x 60.5|54 x 122 x 60.5||||
|---|---|---|---|---|---|---|---|---|
|**415 / 240**||||**415 / 240**|||||
|**10...240**||||**10...240**|||||
|IEC 60947-7-1||||IEC 60947-7-1|||||
|**IEC**|**UL**|**CSA**||**IEC**|**UL**|**CSA**|||
|1000|600||600|1000|600||600||
|415|380||600|415|380||600||
|240|kcmil 300...kcmil 500|kcmil 300...kcmil 500||240|kcmil 300...kcmil 500|kcmil 300...kcmil 500|||
||8 / 3||||8 / 3||||
||/ 5VA||||/ 5VA||||
|? r u# a||||? r u#|||||
|**Rated connection**||||**Rated connection**|||||
||||||||||
||||||||||
|25...60 Nm M 16||||25...60 Nm M 16|||||
||||||||||
|Conductor connection with cable lugs according to DIN 46234 and DIN||||Conductor connection with cable lugs according to DIN 46234 and DIN<br>Conductor connection with cable lugs according to DIN 46234 and DIN||||Conductor connection with cable lugs according to DIN 46234 and DIN|
|46235, from 70 .. 240 mm²|46235, from 70 .. 240 mm²|||46235, from 70 .. 240 mm²|46235, from 70 .. 240 mm²||||
||||||||||
|**Type**|||**Qty.**|**Order No.**<br>**Type**|||**Qty.**|**Order No.**|
|SAKG 54 II|||5|**0170720000**<br>SAKG 54 II/GW|||5|**0185420000**|
||||||||||
||||||||||
|**Type**|**current**||**Qty.**|**Order No.**<br>**Type**|**current**||**Qty.**|**Order No.**|
|QL 2 SAKG54|415 A||5|**0264400000**<br>QL 2 SAKG54|415 A||5|**0264400000**|
|QL 3 SAKG54|415 A||5|**0408000000**<br>QL 3 SAKG54|415 A||5|**0408000000**|
|QL 4 SAKG54|415 A||5|**0247400000**<br>QL 4 SAKG54|415 A||5|**0247400000**|
||**Width**||||**Width**||||
|EP 2 SAKG46/32 HP/DBR||2 mm|10|**0205300000**<br>EP 2 SAKG46/32 HP/DBR||2 mm|10|**0205300000**|
|EP 2 SAKG46/32 HP/TF/GE||2 mm|10|**0205400000**<br>EP 2 SAKG46/32 HP/TF/GE||2 mm|10|**0205400000**|
||||||||||
||||||||||
||||||||||
|TW SAKG46 HP/DBR/2||2 mm|10|**0177100000**<br>TW SAKG46 HP/DBR/2||2 mm|10|**0177100000**|
|TW SAKG46 HP/TF/GE/2||2 mm|10|**0179900000**<br>TW SAKG46 HP/TF/GE/2||2 mm|10|**0179900000**|
DEK 5/5
DEK 5/5
**B**
**B.53**
**Stud terminal - KST**
**10 mm² KST 6**
**16 mm²**
**B**
## **TS 32 / PA**
**KST 5**
|In hazardous area applications, the installation instructions|In hazardous area applications, the installation instructions||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|and the rated data specifications for accessories given in the|||||||||||||||||
|technical appendix must be followed.|||||||||||||||||
|Width/Length/height with TS32x7.5|mm|24 x 60 x 55|24 x 60 x 55|||||||22 x 60 x 60|22 x 60 x 60||||||
|max. current / max. cond. cross-section|A/mm²|**57 /**|**57 /**|||||||**76 /**|**76 /**||||||
|Max. clamping range|mm²|||||||||**...**|||||||
|**Technical data**|||||||||||||||||
|**Rated data**||**IEC**|||**UL**|**CSA**||||**IEC**|||**UL**|**CSA**|||
|Rated voltage|V|1000|||600||600|||1000|||600||600||
|Rated current|A||57||50||65||||76||65||80||
|Rated cross-section|mm²||10|AWG 12...6||AWG 8...2|||||16|AWG 12...6||AWG 12...6|||
|Rated impulse voltage / Pollution severity|kV/-||||8 / 3||||||||8 / 3||||
|Gauge to IEC 60947-1 / UL94 Flammabilityclass|||||/ V2|/ V2|||||||/ V2|/ V2|||
|Approvals|r# a||# a|||||||r# a|# a||||||
|||**Rated connection**||||||||**Rated connection**|||||||
|Tighteningtorque range(clampingscrew)||2.0...4.0 Nm||||||||3.0...6.0 Nm|||||||
|**Note**|||||||||||||||||
|**Ordering data**|||||||||||||||||
|**Version**||**Type**|||||**Qty.**|**Order No.**||**Type**|||||**Qty.**|**Order No.**|
|TS 35 x 7,5|TS 35 x 7,5|KST 5|||||25|**9503370000**||KST 6|||||25|**9501310000**|
|**Note**|||||||||||||||||
|**Accessories**|||||||||||||||||
|**Screwable cross-connection**||**Type**|||||**Qty.**|**Order No.**||**Type**|||**current**||**Qty.**|**Order No.**|
||2-pole|||||||||QL 2 KST6|QL 2 KST6||||5|**9501350000**|
|**Partitionplate**||||||**Width**||||||||**Width**|||
||left|TW KST5-12 LI/NO 160/HM|||TW KST5-12 LI/NO 160/HM||10|**1752800000**||TW KST5-12 LI/NO 160/HM|||TW KST5-12 LI/NO 160/HM||10|**1752800000**|
||right|TW KST5-12 RE/NO 160/HM|||TW KST5-12 RE/NO 160/HM||10|**1718530000**||TW KST5-12 RE/NO 160/HM|||TW KST5-12 RE/NO 160/HM||10|**1718530000**|
## **Technical data**
**Ordering data Version Note**
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
**B.54**
**Stud terminal - KST**
||||||||||||||||||||||||||**SAK-Series TS 32**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**KST 8**|||||||**35 mm²**|**KST 10**|||||||**70 mm²**||**KST 12**|||||||**95 mm²**|**SAK-Series TS 32**|
|24 x 60 x 72<br>**125 /**||‘Com.<br>o—0O||||||34 x 60 x 82<br>**192 /**||val||2<br>o————_o|||||34 x 60 x 82<br>**232 /**|al||o_o|||||**B**<br>~|
|**...**||||||||**...**|||||||||**...**|||||||||
|**IEC**||**UL**|**CSA**|||||**IEC**||**UL**||**CSA**|||||**IEC**||**UL**|**CSA**||||||
|1000||600||600||||1000||600|||600||||1000||600||600|||||
|125||115||130||||192||175|||200||||232||200||250|||||
|35|AWG 12...2||AWG 12...2||AWG 12...2|||70|AWG 12...2/0||AWG 12...2/0|||AWG 12...2/0|||95|AWG 12...3||AWG 12...3/0||AWG 12...3/0||||
|||8 / 3||||||||8 / 3|8 / 3||||||||8 / 3|8 / 3||||||
|||/ V2|/ V2|||||||/ V2|/ V2||||||||/ V2|||||||
|r# a||||||||r# a|||||||||r# a|||||||||
|**Rated connection**||||||||**Rated connection**|||||||||**Rated connection**|||||||||
|6.0...12 Nm||||||||10...20 Nm|||||||||14...31 Nm|||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|**Type**||||**Qty.**|||**Order No.**|**Type**||||||**Qty.**|**Order No.**||**Type**|||||**Qty.**||**Order No.**||
|KST 8|||||25||**9501320000**|KST 10||||||20|**9501330000**||KST 12|||||20||**9501340000**||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|**Type**||**current**|||**Qty.**||**Order No.**|**Type**||**current**||||**Qty.**|**Order No.**||**Type**||**current**|||**Qty.**||**Order No.**||
|QL 2 KST8|||||5||**9501360000**|QL 2 KST10||||||5|**9501370000**||QL 2 KST12||232 A|||5||**9501380000**||
||||**Width**||||||||**Width**||||||||**Width**|||||||
|TW KST5-12 LI/NO 160/HM||TW KST5-12 LI/NO 160/HM|||10||**1752800000**|TW KST5-12 LI/NO 160/HM||TW KST5-12 LI/NO 160/HM||||10|**1752800000**||TW KST5-12 LI/NO 160/HM||TW KST5-12 LI/NO 160/HM|||10||**1752800000**||
|TW KST5-12 RE/NO 160/HM||TW KST5-12 RE/NO 160/HM|||10||**1718530000**|TW KST5-12 RE/NO 160/HM||TW KST5-12 RE/NO 160/HM||||10|**1718530000**||TW KST5-12 RE/NO 160/HM||TW KST5-12 RE/NO 160/HM|||10||**1718530000**||
DEK 5/5
DEK 5/5
DEK 5/5
**B.55**
**Terminals with electronic components**
**DK 4 LD/2**
**B**
## **with indication**
## **DK 4 LD/1**
## **DC voltage indicator**
## **4 mm²**
## **DC voltage indicator**
## **4 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [503 x 546] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|6 x 50 x 56.5|6 x 50 x 56.5|
|max. current / max. cond. cross-section|A/mm²|10 / 4|10 / 4|
|Max. clamping range|mm²|0.5...4|FF.|0.5...4|Ff.|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|24|24|
|Rated current|A|10|10|
|Rated cross-section|mm²|4|4|
|Rated impulse voltage / Pollution severity|kV/-|1 / 3|1 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|A3 / V2|
|Approvals|r #|r #|
|Electronic fixtures|
|Diode reverse voltage / Diode current|-|
|Operating voltage for display, min. / Current|V/mA|24 / 5|24 / 5|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|Tightening torque range (clamping screw)|0.5...1.0 Nm (M 3)|0.5...1.0 Nm (M 3)|
|Stripping length / Blade size|mm/-|9 / 0.6 x 3.5 mm|9 / 0.6 x 3.5 mm|
|Note|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Red LED|DK 4/32 LD ROT 24VDC A1|25|0495360000|DK 4/32 LD ROT 24VDC A2|25|0474460000|
|Green LED|DK 4/32 LD GR 24VDC A2|25|0646560000|
|Neon lamp|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|Q 2 AKZ4|32 A|50|0336400000|Q 2 AKZ4|32 A|50|0336400000|
|3-pole|Q 3 AKZ4|32 A|50|0336500000|Q 3 AKZ4|32 A|50|0336500000|
|4-pole|Q 4 AKZ4|32 A|50|0336600000|Q 4 AKZ4|32 A|50|0336600000|
|External cross-connection|
|2-pole|QB 2 WI RA6 IS|27 A|50|0482700000|QB 2 WI RA6 IS|27 A|50|0482700000|
|3-pole|QB 3 WI RA6 IS|27 A|50|0482800000|QB 3 WI RA6 IS|27 A|50|0482800000|
|4-pole|QB 4 WI RA6 IS|27 A|50|0482900000|QB 4 WI RA6 IS|27 A|50|0482900000|
|Switchable link|
|Mounting screw|BFSC M2.5X14 SAKD2.5N|100|0266800000|BFSC M2.5X14 SAKD2.5N|100|0266800000|
|Switchable link|VL 2 AKZ4/DK4|50|0446700000|VL 2 AKZ4/DK4|50|0446700000|
|Connecting sleeve|VH 10/4/2.8 AKZ4|50|0446600000|VH 10/4/2.8 AKZ4|50|0446600000|
|Testing / Checking|Width|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|End plate / Partition plate|
|beige|AP DK4|1.5 mm|20|0359260000|AP DK4|1.5 mm|20|0359260000|
|Small partition|
|Small partition|TSCH 4 AKZ4|6 mm|100|0363360000|TSCH 4 AKZ4|6 mm|100|0363360000|
|Marking systems|(see assortment in catalogue 7)|
|DEK 5/6|DEK 5/6|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
## **Accessories**
**==> picture [159 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
**B.56**
**Terminals with electronic components**
**DK 4 LD/3 4 mm² DK 4 GL 4 mm² DC voltage indicator AC voltage indicator**
**==> picture [331 x 589] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|DC voltage indicator|AC voltage indicator|
|te|crs|||a=|ore|
|6 x 50 x 56.5|6 x 50 x 56.5|
|10 / 4|10 / 4|
|0.5...4|0.33...4|
|IEC 60947-7-1|IEC 60947-7-1|
|IEC|UL|CSA|IEC|UL|CSA|
|24|115|
|10|10|
|4|4|
|1 / 3|1 / 3|
|A3 / V2|A3 / V2|
|#|r #|
|24 / 5|24 / 5|
|Rated connection|Rated connection|
|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|0.5...1.0 Nm (M 3)|0.5...1.0 Nm (M 3)|
|9 / 0.6 x 3.5 mm|9 / 0.6 x 3.5 mm|
|Type|Qty.|Order No.|Type|Qty.|Order No.|
|DK 4/32 LD ROT 24VDC|25|0210160000|
|DK 4/32 GL 100K 115VAC|25|0569560000|
|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|Q 2 AKZ4|32 A|50|0336400000|Q 2 AKZ4|32 A|50|0336400000|
|Q 3 AKZ4|32 A|50|0336500000|Q 3 AKZ4|32 A|50|0336500000|
|Q 4 AKZ4|32 A|50|0336600000|Q 4 AKZ4|32 A|50|0336600000|
|QB 2 WI RA6 IS|27 A|50|0482700000|QB 2 WI RA6 IS|27 A|50|0482700000|
|QB 3 WI RA6 IS|27 A|50|0482800000|QB 3 WI RA6 IS|27 A|50|0482800000|
|QB 4 WI RA6 IS|27 A|50|0482900000|QB 4 WI RA6 IS|27 A|50|0482900000|
|BFSC M2.5X14 SAKD2.5N|100|0266800000|BFSC M2.5X14 SAKD2.5N|100|0266800000|
|VL 2 AKZ4/DK4|50|0446700000|VL 2 AKZ4/DK4|32 A|50|0446700000|
|VH 10/4/2.8 AKZ4|50|0446600000|VH 10/4/2.8 AKZ4|50|0446600000|
|Width|Width|
|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|AP DK4|1.5 mm|20|0359260000|AP DK4|1.5 mm|20|0359260000|
|TSCH 4 AKZ4|6 mm|100|0363360000|TSCH 4 AKZ4|6 mm|100|0363360000|
**----- End of picture text -----**<br>
DEK 5/6
DEK 5/6
**B**
**B.57**
**Terminals with electronic components**
**DK 4 D/2 4 mm²**
**B** »
## **with diodes**
## **DK 4 D/1**
## **4 mm²**
**Diode terminal, e.g. as reverse polarity protection**
**Suppressor circuit for contactor and solenoid valve (DC voltage)**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [465 x 194] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|6 x 50 x 56.5|6 x 50 x 56.5|
|max. current / max. cond. cross-section|A/mm²|10 / 4|10 / 4|
|Max. clamping range|mm²|0.33...4|o———_|0|0.33...4|
|Technical data|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|380|300|380|300|
|Rated current|A|10|10|10|10|
|Rated cross-section|mm²|4|AWG 22...12|4|AWG 22...12|
|Rated impulse voltage / Pollution severity|kV/-|/ 3|/ 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|A3 / V2|
|Approvals|r #|r #|
|Electronic fixtures|
|Diode reverse voltage / Diode current|A|1000 / 1|1000 / 1|
|Operating voltage for display, min. / Current|-/A|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|Tightening torque range (clamping screw)|0.5...0.8 Nm (M 3)|0.5...0.8 Nm (M 3)|
|Stripping length / Blade size|mm/-|9 / 0.6 x 3.5 mm|9 / 0.6 x 3.5 mm|
|Note|Diode current: max 1A. (1 N 4007)|Diode current: max 1A. (1 N 4007)|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering data**
**==> picture [503 x 228] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Red LED|DK 4/32 1D CSA GET.SCH.|25|0544660000|DK 4/32 1D CSA A1|25|0484060000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-polepoleole|Q 2 AKZ4|32 A|50|0336400000|Q 2 AKZ4|32 A|50|0336400000|
|3-polepoleole|Q 3 AKZ4|32 A|50|0336500000|Q 3 AKZ4|32 A|50|0336500000|
|4-polepoleole|Q 4 AKZ4|32 A|50|0336600000|Q 4 AKZ4|32 A|50|0336600000|
|External cross-connection|
|2-polepoleole|QB 2 WI RA6 IS|27 A|50|0482700000|QB 2 WI RA6 IS|27 A|50|0482700000|
|3-polepoleole|QB 3 WI RA6 IS|27 A|50|0482800000|QB 3 WI RA6 IS|27 A|50|0482800000|
|4-polepoleole|QB 4 WI RA6 IS|27 A|50|0482900000|QB 4 WI RA6 IS|27 A|50|0482900000|
|Switchable link|
|Mounting screwg screw screw|BFSC M2.5X14 SAKD2.5N|100|0266800000|BFSC M2.5X14 SAKD2.5N|100|0266800000|
|Switchable link|VL 2 AKZ4/DK4|32 A|50|0446700000|VL 2 AKZ4/DK4|32 A|50|0446700000|
|Connecting sleeveg sleeve sleeve|VH 10/4/2.8 AKZ4|50|0446600000|VH 10/4/2.8 AKZ4|50|0446600000|
|Testing / Checking|Width|Width|
|Test plugpluglugg|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|End plate / Partition plate|
|beigegee|AP DK4|1.5 mm|20|0359260000|AP DK4|1.5 mm|20|0359260000|
|Small partition|
|Small partition|artition|TSCH 4 AKZ4|6 mm|100|0363360000|TSCH 4 AKZ4|6 mm|100|0363360000|
**----- End of picture text -----**<br>
Red LED 2-polepoleole 3-polepoleole 4-polepoleole 2-polepoleole 3-polepoleole 4-polepoleole Mounting screwg screw screw Switchable link Connecting sleeveg sleeve sleeve Test plugpluglugg Socket beigegee Small partition
## **Accessories**
**==> picture [159 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
DEK 5/6
DEK 5/6
**B.58**
**Terminals with electronic components**
**B**
**==> picture [335 x 327] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|DK 4 D/3|4 mm²|DK 4 D/4|4 mm²|
|Suppressor circuit for contactor and soleno-|Diode terminal for lamp test circuits|
|id valve (DC voltage)|
|ivi|Oo|
|6 x 50 x 56.5|6 x 50 x 56.5|
|10 / 4|10 / 4|
|0.33...4|0.33...4|
|IEC|UL|CSA|IEC|UL|CSA|
|380|300|380|300|
|10|10|10|10|
|4|4|
|/ 3|/ 3|
|A3 / V2|A3 / V2|
|r #|r #|
|1000 / 1|1000 / 1|
|Rated connection|Rated connection|
|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|0.5...0.8 Nm (M 3)|0.5...0.8 Nm (M 3)|
|9 / 0.6 x 3.5 mm|9 / 0.6 x 3.5 mm|
|Diode current: max 1A. (1 N 4007)|Diode current: max 1A. (1 N 4007)|
**----- End of picture text -----**<br>
**==> picture [329 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|Type|Qty.|Order No.|Type|Qty.|Order No.|
|DK 4/32 1D CSA A2|25|0467960000|DK 4/32 2D CSA GET.SCH.|25|0642760000|
**----- End of picture text -----**<br>
**DK 4 D/5 4 mm²**
**Diode terminal for lamp test circuits**
**==> picture [157 x 240] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|6 x 50 x 56.5|
|10 / 4|
|0.33...4|
|IEC|UL|CSA|
|380|300|
|10|10|
|4|
|/ 3|
|A3 / V2|
|r #|
|1000 / 1|
|Rated connection|
|0.5...4 / 0.5...4|
|0.5...4 / 0.5...4|
|0.5...0.8 Nm (M 3)|
|9 / 0.6 x 3.5 mm|
|Diode current: max 1A. (1 N 4007)|
|Type|Qty.|Order No.|
|DK 4/32 2D CSA A2|25|0523760000|
**----- End of picture text -----**<br>
**==> picture [503 x 172] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|Q 2 AKZ4|32 A|50|0336400000|Q 2 AKZ4|32 A|50|0336400000|Q 2 AKZ4|32 A|50|0336400000|
|Q 3 AKZ4|32 A|50|0336500000|Q 3 AKZ4|32 A|50|0336500000|Q 3 AKZ4|32 A|50|0336500000|
|Q 4 AKZ4|32 A|50|0336600000|Q 4 AKZ4|32 A|50|0336600000|Q 4 AKZ4|32 A|50|0336600000|
|QB 2 WI RA6 IS|27 A|50|0482700000|QB 2 WI RA6 IS|27 A|50|0482700000|QB 2 WI RA6 IS|27 A|50|0482700000|
|QB 3 WI RA6 IS|27 A|50|0482800000|QB 3 WI RA6 IS|27 A|50|0482800000|QB 3 WI RA6 IS|27 A|50|0482800000|
|QB 4 WI RA6 IS|27 A|50|0482900000|QB 4 WI RA6 IS|27 A|50|0482900000|QB 4 WI RA6 IS|27 A|50|0482900000|
|BFSC M2.5X14 SAKD2.5N|100|0266800000|BFSC M2.5X14 SAKD2.5N|100|0266800000|BFSC M2.5X14 SAKD2.5N|100|0266800000|
|VL 2 AKZ4/DK4|50|0446700000|VL 2 AKZ4/DK4|50|0446700000|VL 2 AKZ4/DK4|32 A|50|0446700000|
|VH 10/4/2.8 AKZ4|50|0446600000|VH 10/4/2.8 AKZ4|50|0446600000|VH 10/4/2.8 AKZ4|50|0446600000|
|Width|Width|Width|
|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|AP DK4|1.5 mm|20|0359260000|AP DK4|1.5 mm|20|0359260000|AP DK4|1.5 mm|20|0359260000|
|TSCH 4 AKZ4|6 mm|100|0363360000|TSCH 4 AKZ4|6 mm|100|0363360000|TSCH 4 AKZ4|6 mm|100|0363360000|
**----- End of picture text -----**<br>
DEK 5/6
DEK 5/6
DEK 5/6
**B.59**
**Terminals with electronic components**
**DK 4 D/7**
**B**
## **with diodes**
## **DK 4 D/6**
**Diode terminal for lamp test circuits**
## **4 mm²**
**4 mm²**
**Diode terminal for lamp test circuits, with protective resistor**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [503 x 240] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|6 x 50 x 56.5|6 x 50 x 56.5|
|max. current / max. cond. cross-section|A/mm²|10 / 4|10 / 4|
|Max. clamping range|mm²|0.33...4|0.33...4|
|Technical data|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|380|300|24|300|
|Rated current|A|10|10|10|10|
|Rated cross-section|mm²|4|4|
|Rated impulse voltage / Pollution severity|kV/-|/ 3|/ 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|A3 / V2|
|Approvals|r #|r #|
|Electronic fixtures|
|Diode reverse voltage / Diode current|A|1000 / 1|/ 1|
|Operating voltage for display, min. / Current|-/A|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|Tightening torque range (clamping screw)|0.5...0.8 Nm (M 3)|0.5...0.8 Nm (M 3)|
|Stripping length / Blade size|mm/-|9 / 0.6 x 3.5 mm|9 / 0.6 x 3.5 mm|
|Note|Diode current: max 1A. (1 N 4007)|Diode current: max 1A. (1 N 4007)|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|Red LED|DK 4/32 2D A1|25|0663960000|DK 4/32 1D 1K5|25|0685260000|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
**Version Note**
Red LED 2-polepoleole 3-polepoleole 4-polepoleole 2-polepoleole 3-polepoleole 4-polepoleole Mounting screwg screw screw Switchable link Connecting sleeveg sleeve sleeve Test plugpluglugg Socket beigegee Small partitionpartitionartition
## **Accessories**
**==> picture [503 x 172] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-polepoleole|Q 2 AKZ4|32 A|50|0336400000|Q 2 AKZ4|32 A|50|0336400000|
|3-polepoleole|Q 3 AKZ4|32 A|50|0336500000|Q 3 AKZ4|32 A|50|0336500000|
|4-polepoleole|Q 4 AKZ4|32 A|50|0336600000|Q 4 AKZ4|32 A|50|0336600000|
|External cross-connection|
|2-polepoleole|QB 2 WI RA6 IS|27 A|50|0482700000|QB 2 WI RA6 IS|27 A|50|0482700000|
|3-polepoleole|QB 3 WI RA6 IS|27 A|50|0482800000|QB 3 WI RA6 IS|27 A|50|0482800000|
|4-polepoleole|QB 4 WI RA6 IS|27 A|50|0482900000|QB 4 WI RA6 IS|27 A|50|0482900000|
|Switchable link|
|Mounting screwg screw screw|BFSC M2.5X14 SAKD2.5N|100|0266800000|BFSC M2.5X14 SAKD2.5N|100|0266800000|
|Switchable link|VL 2 AKZ4/DK4|50|0446700000|VL 2 AKZ4/DK4|50|0446700000|
|Connecting sleeveg sleeve sleeve|VH 10/4/2.8 AKZ4|50|0446600000|VH 10/4/2.8 AKZ4|50|0446600000|
|Testing / Checking|Width|Width|
|Test plugpluglugg|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|End plate / Partition plate|
|beigegee|AP DK4|1.5 mm|20|0359260000|AP DK4|1.5 mm|20|0359260000|
|Small partition|
|Small partitionpartitionartition|TSCH 4 AKZ4|6 mm|100|0363360000|TSCH 4 AKZ4|6 mm|100|0363360000|
**----- End of picture text -----**<br>
**==> picture [159 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
DEK 5/6
DEK 5/6
**B.60**
**Terminals with electronic components**
**DK 4 RC**
**B**
## **with electronic components**
## **4 mm²**
**DKT 4 PT 100 4 mm² Diode terminal for central control and communication system**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS32x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [281 x 168] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Width/Length/height with TS32x7.5|mm|18 x 50 x 56.5|
|max. current / max. cond. cross-section|A/mm²|10 / 4|
|Max. clamping range|mm²|0.33...4|
|Technical data|
|Rated data|IEC|UL|CSA|
|Rated voltage|V|230|
|Rated current|A|10|
|Rated cross-section|mm²|4|
|Rated impulse voltage / Pollution severity|kV/-|/ 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|
|Approvals|#|
|Clamped conductors (H05V/H07V)|Rated connection|
|solid / stranded|mm²|0.5...4 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...4|
|Tightening torque range (clamping screw)|0.5...0.8 Nm (M 3)|
|Stripping length / Blade size|mm/-|9 / 0.6 x 3.5 mm|
|Note|
**----- End of picture text -----**<br>
## **Technical data**
6 x 65 x 56.5 **10 / 4 0.33...4 IEC UL CSA** 250 10 4 / 3 A3 / V2 # **Rated connection** 0.5...4 / 0.5...4 0.5...4 / 0.5...2.5 0.4...0.7 Nm (M 2.5) 6 / 0.6 x 3.5 mm
## **Ordering data**
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|DK 4/32 RC 220R/220NF|5|0692160000|
**----- End of picture text -----**<br>
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|DKT 4/32 PT100|10|8014730000|
**----- End of picture text -----**<br>
**Version Note**
**==> picture [503 x 183] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Red LED|DK 4/32 RC 220R/220NF|5|0692160000|DKT 4/32 PT100|10|8014730000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|Q 2 AKZ4|32 A|50|0336400000|Q 2 AKZ4|32 A|50|0336400000|
|3-pole|Q 3 AKZ4|32 A|50|0336500000|Q 3 AKZ4|32 A|50|0336500000|
|4-pole|Q 4 AKZ4|32 A|50|0336600000|Q 4 AKZ4|32 A|50|0336600000|
|External cross-connection|
|2-pole|QB 2 WI RA6 IS|27 A|50|0482700000|QB 2 WI RA6 IS|27 A|50|0482700000|
|3-pole|QB 3 WI RA6 IS|27 A|50|0482800000|QB 3 WI RA6 IS|27 A|50|0482800000|
|4-pole|QB 4 WI RA6 IS|27 A|50|0482900000|QB 4 WI RA6 IS|27 A|50|0482900000|
|End plate / Partition plate|Width|Width|
|beige|AP DK4|1.5 mm|20|0359260000|AP DKT4 PA|1.5 mm|20|0687560000|
|Testing / Checking|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|Small partition|
|Small partition|TSCH 4 AKZ4|6 mm|100|0363360000|TSCH 4 AKZ4|6 mm|100|0363360000|
**----- End of picture text -----**<br>
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/6 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/6
**B.61**
**Earth conductor isolating terminals**
**B**
**==> picture [33 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
SAKT E<br>**----- End of picture text -----**<br>
## **6 mm²**
## **green LED**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
**==> picture [336 x 168] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|19 x 65 x 53.5|
|max. current / max. cond. cross-section|A/mm²|27 / 10|
|Max. clamping range|mm²|0.5...10|
|Technical data|
|et|
|Rated data|IEC|UL|CSA|
|Rated voltaRated currentge|AV|as|6027|Ess|
|Rated cross-section|mm²|6|
|Rated impulse voltage / Pollution severity|kV/-|/ 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A5 / 5VA|
|Approvals|
|Clamped conductors (H05V/H07V)|Rated connection|
|solid / stranded|mm²|0.5...10|
|flexible / Stranded wire with end ferrules|mm²|0.5...6 / 0.5...6|
|Tightening torque range (clamping screw)|0.8...1.6 Nm (M 3.5)|
|Stripping length / Blade size|mm/-|/ 4.0 x 0.8 mm|
|Note|
**----- End of picture text -----**<br>
## **Technical data**
## **Operating mode**
**==> picture [22 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
SAKT E<br>**----- End of picture text -----**<br>
- Slide link is closed
- Auxiliary circuit is **earthed**
- Display is illuminated green
## **Test position**
When measuring insulation resistance with voltages greater than UNom, the earth connection must first be disconnected.
## **Ordering data**
## **SAKT E**
~~OOa~~ **T** SAKT E/32 2LD 60VAC **ype Qty** 5 **. 0699020000Order No.** ~~hl~~
**Version Note**
40...60V~
## **Accessories**
~~TS TS~~ **End bracket Type Width Qty. Order No.** Dark beige Wemid EWK 1 9 mm 50 **0206160000**
- Slide link is opened
- Auxiliary circuit is **not earthed**
- **No** earth fault
- Display illuminated green and red with reduced intensity
- Disconnected earth connection -> When measuring insulation resistance with voltages greater than UNom, the earth connection must be disconnected.
## **Operational malfunction**
## **SAKT E**
- Slide link is opened
- Auxiliary circuit is **not earthed**
- **Earth fault**
(see assortment in catalogue 7)
**For detailed information on other accessories and applications, refer to the „Accessories“ section**
To safe the test sockets use the SD-blade or bits with pilots!
- Display is illuminated red
**B.62**
**Contents**
**C**
## SAK-Series combination foot TS 35 + TS 32
|**SAK-Series combination foot**<br>**TS 35 + TS 32**|**Feed-through modular terminals**<br>TS 35 + TS 32 / PA<br>C.2|
|---|---|
||**Stud terminals**<br>C.6|
||**Fuse terminals**<br>TS 35 + TS 32 / PA<br>C.7|
||**Earth conductor isolating terminals**<br>C.8|
**C.1**
**Feed-through modular terminals**
**SAK 2.5/EN**
**SAK 4/EN**
**4 mm²**
**C**
## **TS 35 + TS 32 / PA**
## **2.5 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS35x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [507 x 563] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|6.1 x 44.5 x 42.5|6.5 x 42 x 47.5|
|max. current / max. cond. cross-section|A/mm²|41 / 6|41 / 6|
|Max. clamping range|mm²|0.13...6|0.13...6|
|Technical data|IEC 60947-7-1|Ex e II|T|II 2 G D|IEC 60947-7-1|Ex e II|T|II 2 G D|
|Rated data|IEC|UL|CSA|EN 60079-7|IEC|UL|CSA|EN 60079-7|
|Rated voltage|V|800|600|600|550|800|600|600|690|
|Rated current|A|24|25|25|21|32|30|36|28|
|Rated cross-section|mm²|2.5|AWG 22...12|AWG 26...10|2.5|4|AWG 22...12|AWG 26...10|4|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|A4 / V2|
|Approvals|r|# i a|KEMA 97ATEX1798 U|r|# i a|KEMA 97ATEX1798 U|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...6 / 0.5...4|0.5...6 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|Tightening torque range (clamping screw)|0.4...0.6 Nm (M 2.5)|0.5...1.0 Nm (M 3)|
|Stripping length / Blade size|mm/-|10 / 0.6 x 3.5 mm|12 / 0.6 x 3.5 mm|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|mm²|...1.5|1.5...1.5|
|flexible / Stranded wire with end ferrules|mm²|0.5...1.5|
|Note|With twin ferrules ZH 0.5 to ZH 1.5, rated voltage is 690 V.|With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|beige|SAK 2.5/EN|100|0218660000|SAK 4/EN|100|0467460000|
|Blue|SAK 2.5/EN BL|100|0218680000|SAK 4/EN BL|100|0467480000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|Q 2 SAK2.5|41 A|50|0337000000|Q 2 SAK4|41 A|50|0336700000|
|3-pole|Q 3 SAK2.5|41 A|50|0337100000|Q 3 SAK4|41 A|50|0336800000|
|4-pole|Q 4 SAK2.5|41 A|50|0337200000|Q 4 SAK4|41 A|50|0336900000|
|10-pole|Q 10 SAK2.5|41 A|20|0368700000|Q 10 SAK4|41 A|20|0368800000|
|Connecting sleeve|
|Mounting screw|
|Lock washer|
|Switchable link|
|Switchable link|VL 2 SAK4|32 A|50|0197000000|
|Connecting sleeve|VH 19/5/3.5 SAK4-16|50|0285100000|
|Mounting screw|BFSC M3X25|100|0292500000|
|Testing / Checking|Width|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/5/2.3/M3 SAK2.5|50|0280600000|STB 14/D5/2.3/M3 SAK2.5|50|0168600000|
|End plate / Partition plate|
|beige|AP SAK2.5/35 + AST3+4|1.5 mm|20|0460560000|AP SAK4-10|1.5 mm|20|0117960000|
|Blue|AP SAK4-10 BL|1.5 mm|20|0117980000|
|beige|TW SAK2.5|2.5 mm|20|0302860000|TW 4 SAK4-10|1.5 mm|20|0130160000|
|Blue|TW SAK2.5 BL|1.5 mm|20|0302880000|TW 4 SAK4-10 BL|1.5 mm|20|0130180000|
|Small partition|
|Small partition|TSCH 1|2 mm|100|0319160000|TSCH 1|2 mm|100|0319160000|
|Cover / warning label|
|Cover / warning label|AD 3 SAK2.5|50|0297900000|AD 4 SAK4|50|0285300000|
|Mounting screw (plastic)|BFSC M3X22 PA/RT|100|0128900000|BFSC M3X22 PA/RT|100|0128900000|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/6|DEK 5/6|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
## **Accessories**
**C.2**
**Feed-through modular terminals**
**SAK 6/EN**
**6 mm² SAK 10/EN**
**SAK 16/EN**
**C**
## **10 mm²**
**16 mm²**
|8 x 40 x 47.5|8 x 40 x 47.5||||||10 x 41.5 x 47.5|10 x 41.5 x 47.5|||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**57 / 10**|||||||**76 / 16**||||||||
|**0.33...10**|||||||**1.5...16**||||||||
|IEC 60947-7-1|||Ex e IIT II 2 G D||||IEC 60947-7-1||||Ex e IIT II 2 G D||||
|**IEC**||**UL**|**CSA**||**EN 60079-7**||**IEC**|**UL**|||**CSA**|||**EN 60079-7**|
|800||600|600||690||800|600|||600|||550|
|41||40|47||36||57|60|||65|||50|
|6|AWG 22...8||AWG 26...6||6||10|AWG 14...6||AWG 16...6||||10|
|||8 / 3||||||8 / 3|8 / 3||||||
|||A5 / V2||||||B6 / V2|B6 / V2||||||
|r #i a|||KEMA 97ATEX1798 U|KEMA 97ATEX1798 U||r #a|||||KEMA 97ATEX1798 U|KEMA 97ATEX1798 U|KEMA 97ATEX1798 U||
|**Rated connection**|||||||**Rated connection**||||||||
|0.5...10 / 0.5...6|||||||1.5...10 / 1.5...16||||||||
|0.5...10 / 0.5...6|||||||1.5...16 / 1.5...10||||||||
|0.8...1.6 Nm(M 3.5)|||||||2.0...4.0 Nm(M 4)||||||||
|12 / 4.0 x 0.8 mm|||||||12 / 1.0 x 5.5 mm||||||||
||||||||||||||||
||||||||||||||||
||||||||||||||||
|For AWG 8-7 and AWG 8-19, tightening torque is 1.21.4 Nm|For AWG 8-7 and AWG 8-19, tightening torque is 1.21.4 Nm|For AWG 8-7 and AWG 8-19, tightening torque is 1.21.4 Nm|||||When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|||When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|||
|12 x 50 x 53.5|12 x 50 x 53.5||||
|---|---|---|---|---|
|**76 / 16**|||||
|**2.5...16**|||||
|IEC 60947-7-1|||Ex e IIT II 2 G D||
|**IEC**|**UL**||**CSA**|**EN 60079-7**|
|1000|600||600|690|
|76|80||87|66|
|16|AWG 12...4||AWG 14...6|16|
||8 / 3||||
||B6 / V2||||
|r #a|||KEMA 97ATEX1798 U|KEMA 97ATEX1798 U|
|**Rated connection**|||||
|2.5...16 / 4...16|||||
|4...16 / 4...16|||||
|2.0...4.0 Nm(M 4)|||||
|15 / 1.0 x 5.5 mm|||||
||||||
||||||
||||||
|Twin wire end ferrules ZH 2.5 - ZH 16 can be used.||Twin wire end ferrules ZH 2.5 - ZH 16 can be used.|||
|**Type**||**Qty.**<br>**Order No.**||**Type**|**Qty.**|**Order No.**||**Type**|**Qty.**|**Order No.**|
|---|---|---|---|---|---|---|---|---|---|---|
|SAK 6/EN||100<br>**0212860000**||SAK 10/EN|100|**0337660000**||SAK 16/EN|50|**0339760000**|
|SAK 6/EN BL||100<br>**0212880000**||SAK 10/EN BL|100|**1784410000**||SAK 16/EN BL|50|**1784390000**|
|With AWG 6 and H07V-R10 conductors, an increased MD torque of 1.4||||A higher torque of 2 to 2.4 Nm is necessary when using H07V-R16 and|A higher torque of 2 to 2.4 Nm is necessary when using H07V-R16 and|||If QIs are aligned side by side, then a TW/AP must be used.|||
|to1.6 Nm should be used.||||AWG 6 conductors.|||||||
||||||||||||
|**Type**|**current**<br>**Qty.**<br>**Order No.**|||**Type**|**current**<br>**Qty.**|**Order No.**||**Type**|**current**<br>**Qty.**|**Order No.**|
|Q 2 SAK6N|32 A|32 A<br>50<br>**0456700000**||Q 2 SAK10|57 A<br>50|**0457100000**||Q 2 SAK16|76 A<br>50|**0457500000**|
|Q 3 SAK6N|57 A|57 A<br>50<br>**0456800000**||Q 3 SAK10|57 A<br>50|**0457200000**||Q 3 SAK16|76 A<br>50|**0457600000**|
|Q 4 SAK6N|57 A|57 A<br>50<br>**0456900000**||Q 4 SAK10|57 A<br>50|**0457300000**||Q 4 SAK16|76 A<br>50|**0457700000**|
|Q 10 SAK6N|32 A|32 A<br>20<br>**0457000000**||Q 10 SAK10|57 A<br>20|**0457400000**||Q 10 SAK16|76 A<br>20|**0457800000**|
||||||||||||
||||||||||||
||||||||||||
||||||||||||
|VL 2 SAK6N/SAKT|32 A|32 A<br>50<br>**0194700000**||VL 2 SAK6N/SAKT|32 A<br>50|**0194700000**||VL 2 SAK16/SAKA|57 A<br>50|**0135800000**|
|VH 19/5/3.5 SAK4-16||50<br>**0285100000**||VH 19/5/3.5 SAK4-16|50|**0285100000**||VH 19/5/3.5 SAK4-16|50|**0285100000**|
|BFSC M3X25||100<br>**0292500000**||BFSC M3X25|100|**0292500000**||BFSC M3X25|100|**0292500000**|
||**Width**||||**Width**||||**Width**||
|PS 4 F.STB 4|7.6 mm<br>20<br>**0299600000**|||PS 4 F.STB 4|7.6 mm<br>20|**0299600000**||PS 4 F.STB 4|7.6 mm<br>20|**0299600000**|
|STB 14/D6/4/M3 SAK10||50<br>**0169900000**||STB 14/D6/4/M3 SAK10|50|**0169900000**||STB 14/D6/4/M3 SAK10|50|**0169900000**|
||||||||||||
|AP SAK4-10|1.5 mm<br>20<br>**0117960000**|||AP SAK4-10|1.5 mm<br>20|**0117960000**||AP SAK16|1.5 mm<br>20|**0271160000**|
|AP SAK4-10 BL|1.5 mm<br>20<br>**0117980000**|||AP SAK4-10 BL|1.5 mm<br>20|**0117980000**||AP SAK16 BL|1.5 mm<br>20|**0271180000**|
|TW 4 SAK4-10|1.5 mm<br>20<br>**0130160000**|||TW 4 SAK4-10|1.5 mm<br>20|**0130160000**|||||
|TW 4 SAK4-10 BL|1.5 mm<br>20<br>**0130180000**|||TW 4 SAK4-10 BL|1.5 mm<br>20|**0130180000**|||||
||||||||||||
|TSCH 1|2 mm<br>100<br>**0319160000**|||TSCH 1|2 mm<br>100|**0319160000**||TSCH 1|2 mm<br>100|**0319160000**|
||||||||||||
|AD 4 SAK6N||50<br>**0196600000**||AD 4 SAK10|50|**0178600000**||AD 4 SAK16|50|**0518200000**|
|BFSC M3X22 PA/RT||100<br>**0128900000**||BFSC M3X22 PA/RT|100|**0128900000**||BFSC M3X22 PA/RT|100|**0128900000**|
|DEK 5/8||||DEK 5/5||||DEK 5/5|||
|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V.|||||||||
**C.3**
**Feed-through modular terminals**
**DK 4 Q/EN**
**35 mm²**
**4 mm²**
**C** =
## **TS 35 + TS 32 / PA**
## **SAK 35/EN**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS35x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [507 x 563] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|18 x 58 x 63.5|6.5 x 54 x 47.5|
|max. current / max. cond. cross-section|A/mm²|150 / 50|41 / 6|
|Max. clamping range|mm²|2.5...50|0.13...6|
|Technical data|IEC 60947-7-1|Ex e II|T|II 2 G D|IEC 60947-7-1|Ex e II|T|II 2 G D|
|Rated data|IEC|UL|CSA|EN 60079-7|IEC|UL|CSA|EN 60079-7|
|Rated voltage|V|1000|600|600|690|500|600|600|690|
|Rated current|A|125|115|145|109|32|30|36|28|
|Rated cross-section|mm²|35|AWG 12...2|AWG 12...2|35|4|AWG 22...12|AWG 26...10|4|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|B8 / V2|A4 / V2|
|Approvals|r|# i|KEMA 97ATEX1798 U|KEMA 97ATEX1798 U|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|2.5...16 / 4...50|0.5...6 / 0.5...4|
|flexible / Stranded wire with end ferrules|mm²|2.5...35 / 2.5...35|0.5...4 / 0.5...2.5|
|Tightening torque range (clamping screw)|4.0...5.0 Nm (M 6)|0.5...1.0 Nm (M 3)|
|Stripping length / Blade size|mm/-|18 / 6.5 x 1.2 mm|12 / 0.6 x 3.5 mm|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|mm²|2.5...16 16|1.5...1.5|
|flexible / Stranded wire with end ferrules|mm²|2.5...16 / 2.5...16|0.5...1.5|
|Note|The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-|With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.|
|ded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used.|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|beige|SAK 35/EN|20|0339860000|DK 4 Q/EN|100|1907040000|
|Blue|SAK 35/EN BL|20|1784400000|DK 4 Q/EN BL|100|1907030000|
|Note|It is possible to use twin ferrules with identical rated voltages (LAB 13090).|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAK35|99 A|20|0123600000|Q 2 SAK4|41 A|50|0336700000|
|3-pole|QL 3 SAK35|99 A|20|0123700000|Q 3 SAK4|41 A|50|0336800000|
|4-pole|QL 4 SAK35|99 A|20|0123800000|Q 4 SAK4|41 A|50|0336900000|
|10-pole|QL 10 SAK35|99 A|20|0338600000|Q 10 SAK4|41 A|20|0368800000|
|Connecting sleeve|VH 17/8/5 SAK35|50|0267000000|
|Mounting screw|BFSC M4X30|50|0267100000|
|Lock washer|SS M4 D 128-A 4|100|0136400000|
|Switchable link|
|Switchable link|VL 2 SAK4|32 A|50|0197000000|
|Connecting sleeve|VH 19/5/3.5 SAK4-16|50|0285100000|
|Mounting screw|BFSC M3X25|100|0292500000|
|Testing / Checking|Width|Width|
|Test plug|PS 4 F.STB 4|7.6 mm|20|0299600000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 16/D7/4/M4 SAK35|50|0140200000|STB 14/D5/2.3/M3 SAK2.5|50|0168600000|
|End plate / Partition plate|
|beige|AP SAK35/TW SAK16|1.5 mm|10|0303660000|AP SAK4-10|1.5 mm|20|0117960000|
|Blue|AP SAK35/TW SAK16 BL|1.5 mm|10|0303680000|AP SAK4-10 BL|1.5 mm|20|0117980000|
|beige|TW SAK35|1.5 mm|20|0304360000|TW 4 SAK4-10|1.5 mm|20|0130160000|
|Blue|TW 4 SAK4-10 BL|1.5 mm|20|0130180000|
|Small partition|
|Small partition|TSCH 1|2 mm|100|0319160000|
|Cover / warning label|
|Cover / warning label|AD 4 SAK35|50|0178700000|AD 4 SAK4|50|0285300000|
|Mounting screw (plastic)|BFSC M4X32 PA/RT|100|0129100000|BFSC M3X22 PA/RT|100|0128900000|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|DEK 5/5 / SCHT 7|DEK 5/6|
|For detailed information on other accessories and ap-|If QIs are aligned side by side, then a TW/AP must be used.|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
## **Accessories**
**C.4**
**Feed-through modular terminals**
**DK 4 QV/EN**
**C**
## **4 mm²**
6.5 x 54 x 47.5 **41 / 6 0.13...6**
|IEC 60947-7-1|IEC 60947-7-1|IEC 60947-7-1|Ex e IIT II 2 G D|Ex e IIT II 2 G D|
|---|---|---|---|---|
||**IEC**|**UL**|**CSA**|**EN 60079-7**|
||500|600|600|690|
||32|30|36|28|
||4|AWG 22...12|AWG 26...10|4|
|||8 / 3|||
|||A4 / V2|||
||||KEMA 97ATEX1798 U|KEMA 97ATEX1798 U|
**Rated connection**
0.5...6 / 0.5...4 0.5...4 / 0.5...2.5 0.5...1.0 Nm (M 3) 12 / 0.6 x 3.5 mm 1.5...1.5 0.5...1.5
With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V.
|**Type**|**Qty.**|**Order No.**|
|---|---|---|
|DK 4 QV/EN|100|**1907020000**|
|**Type**|**current**<br>**Qty.**<br>**Order No.**|
|---|---|
|Q 2 SAK4|41 A<br>50<br>**0336700000**|
|Q 3 SAK4|41 A<br>50<br>**0336800000**|
|Q 4 SAK4|41 A<br>50<br>**0336900000**|
|Q 10 SAK4|41 A<br>20<br>**0368800000**|
|||
|||
|||
|||
|VL 2 SAK4|50<br>**0197000000**|
|VH 19/5/3.5 SAK4-16|50<br>**0285100000**|
|BFSC M3X25|100<br>**0292500000**|
||**Width**|
|PS 2.3 RT|5.4 mm<br>20<br>**0180400000**|
|STB 14/D5/2.3/M3 SAK2.5|50<br>**0168600000**|
|||
|AP SAK4-10|1.5 mm<br>20<br>**0117960000**|
|AP SAK4-10 BL|1.5 mm<br>20<br>**0117980000**|
|TW 4 SAK4-10|1.5 mm<br>20<br>**0130160000**|
|TW 4 SAK4-10 BL|1.5 mm<br>20<br>**0130180000**|
|||
|TSCH 1|2 mm<br>100<br>**0319160000**|
|||
|AD 4 SAK4|50<br>**0285300000**|
|BFSC M3X22 PA/RT|100<br>**0128900000**|
|DEK 5/6||
**C.5**
**Stud terminals**
**STL 5**
**16 mm²**
**C**
**ST 5**
**Screw thread M5**
## **16 mm²**
## **Screw thread M5**
**==> picture [455 x 224] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|In hazardous area applications, the installation instructions|
|and the rated data specifications for accessories given in the|
|technical appendix must be followed.|Le \®|Lee|
|Width/Length/height with TS35x7.5|mm|16.4 x 54.22 x 47.1|16.4 x 54.22 x 47.1|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
|Technical data|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|800|600|800|600|
|Rated current|A|76|65|76|65|
|Rated cross-section|mm²|16|AWG 12...10|16|AWG 12...10|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|/ V-0|/ V-0|
|Approvals|a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|-|
|flexible / Stranded wire with end ferrules|-|
|Note|
**----- End of picture text -----**<br>
## **Technical data**
**Ordering data Version Note**
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|ST 5 PA/BE|20|0448360000|
**----- End of picture text -----**<br>
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|STL 5|20|0448460000|
**----- End of picture text -----**<br>
## **Accessories**
**==> picture [329 x 25] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|End plate / Partition plate|Type|Width|Qty.|Order No.|
|beige|AP ST5 PPO/SW|10|0447240000|
|beige|TW ST5 PA/BE|10|0477660000|
**----- End of picture text -----**<br>
**==> picture [155 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Type|Width|Qty.|Order No.|
|AP ST5 PPO/SW|10|0447240000|
|TW ST5 PA/BE|10|0477660000|
**----- End of picture text -----**<br>
(see assortment in catalogue 7)
**For detailed information on other accessories and applications, refer to the „Accessories“ section**
**C.6**
**Fuse terminals**
**KDKS 1 m. LED**
**C**
## **TS 35 + TS 32 / PA**
**ASK 1**
**4 mm²**
**4 mm²**
## **With or without LED**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
8.1 x 58 x 43 **6.3 / 4 0.13...4**
8 x 62.75 x 55.5 **6.3 / 4 0.5...4**
## **Technical data**
**==> picture [159 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Rated data|
|Rated voltage|V|
|Rated current|A|
|Rated cross-section|mm²|
|Rated impulse voltage / Pollution severity|kV/-|
|Gauge to IEC 60947-1 / UL94 Flammability class|
|Approvals|
|Clamped conductors (H05V/H07V)|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|Note|
**----- End of picture text -----**<br>
**IEC UL CSA** 500 6.3 4 AWG 22...12 AWG 26...12 6 / 3 A3 / V2 r # a **Rated connection** 0.5...4 0.5...4 / 0.5...4 0.6...0.8 Nm (M 3) 9 / 0.6 x 3.5 mm Note: max. conductor size = 2.5 mm² when using the cross-connection. Twin wire-end ferrules ZH 0.5 - ZH 2.5 can be used.
**IEC UL CSA** 500 6.3 4 / 3 A3 / V2
# **Rated connection** 0.5...4 0.5...4 / 0.5...4 0.5...0.8 Nm (M 3) 9 / 0.6 x 3.5 mm Note: max. conductor size = 2.5 mm² when using the cross-connection.
## **Ordering data**
**==> picture [155 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|ASK 1/EN|100|0474560000|
|ASK 1/EN LD 1D 230VAC|25|0225760000|
|ASK 1/EN LD 120K 230VDC|25|0225660000|
|ASK 1/EN LD 1D 115VAC|25|0225560000|
|ASK 1/EN LD 56K 115VDC|25|0225460000|
|ASK 1/EN LD 33K 60VDC|25|0226460000|
|ASK 1/EN LD 1D 48VAC|25|0225360000|
|ASK 1/EN LD 27K 48VDC|25|0225260000|
|ASK 1/EN LD 1D 24VAC|25|0222860000|
|ASK 1/EN LD 15K 24VDC|25|0222760000|
**----- End of picture text -----**<br>
**Version**
**==> picture [329 x 182] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|500 V AC/DC|ASK 1/EN|100|0474560000|
|With LED 230 V AC|ASK 1/EN LD 1D 230VAC|25|0225760000|
|With LED 230 V DC|ASK 1/EN LD 120K 230VDC|25|0225660000|
|With LED 115 V AC|ASK 1/EN LD 1D 115VAC|25|0225560000|
|With LED 115 V DC|ASK 1/EN LD 56K 115VDC|25|0225460000|
|With LED 60 V DC|ASK 1/EN LD 33K 60VDC|25|0226460000|
|With LED 48 V AC|ASK 1/EN LD 1D 48VAC|25|0225360000|
|With LED 48 V DC|ASK 1/EN LD 27K 48VDC|25|0225260000|
|With LED 24 V AC|ASK 1/EN LD 1D 24VAC|25|0222860000|
|With LED +- 24 V DC|ASK 1/EN LD 15K 24VDC|25|0222760000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|
|2-pole|QB 2 WI RA8 IS|27 A|50|0461100000|
|3-pole|QB 3 WI RA8 IS|27 A|50|0461200000|
|4-pole|QB 4 WI RA8 IS|27 A|50|0461300000|
|End plate / Partition plate|Width|
|AP ASK1|1.5 mm|20|0380360000|
**----- End of picture text -----**<br>
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/8 / SCHT 7 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
**==> picture [155 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|KDKS1/EN LD 230VAC|25|8148910000|
|KDKS1/EN LD 115VAC|25|8142840000|
|KDKS1/EN LD 48 VAC|25|8148920000|
|KDKS1/EN LD 24 VAC|25|8148930000|
|KDKS1/EN LD 24VDC|25|8146450000|
**----- End of picture text -----**<br>
**==> picture [155 x 52] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Type|current|Qty.|Order No.|
|QB 2 WI RA8 IS|27 A|50|0461100000|
|QB 3 WI RA8 IS|27 A|50|0461200000|
|QB 4 WI RA8 IS|27 A|50|0461300000|
|Width|
|AP KDKS1 EN|20|9503340000|
**----- End of picture text -----**<br>
DEK 5/8
**C.7**
**Earth conductor isolating terminals**
**C**
## **SAKA 10/EN**
## **10 mm²**
## **Neon lamp**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
## **Technical data**
|**Rated data**<br>Rated voltage|V|
|---|---|
|Rated current|A|
|Rated cross-section|mm²|
|Rated impulse voltage / Pollution severity|kV/-|
|Gauge to IEC 60947-1 / UL94 Flammabilityclass||
|Approvals<br>**Clamped conductors(H05V/H07V)**||
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Tighteningtorque range(clampingscrew)||
|Strippinglength / Blade size|mm/-|
|**Note**||
## 24 x 82 x 61.5
**47 / 10 0.5...10**
> ~~po e".LLL_'"7'}~~ **IEC UL CSA** 24 47 10 / 5VA # **Rated connection** 0.5...10 0.5...10 / 0.5...10 1.2...2.2 Nm 12 /
Tightening torque 1.6 Nm for 10 mm² stranded wire.
## **Operating mode**
**SAKA 10** er oa it ' ~~e~~ y' ' ' 'o309 | 9 0 '
- Slide link is closed
- Auxiliary circuit is **earthed**
- Display is illuminated green
## **Test position**
When measuring insulation resistance with voltages greater than UNom, the earth connection must first be disconnected.
## **Ordering data**
## **SAKA 10**
**Version** 24 V~ **T** SAKA 10/EN 2GL 24VUC ~~a~~ **ype Qty** 5 **. 8150150000Order No.** ~~|~~ 230 V~ ~~__OODDOO|>DO.-_~~ SAKA 10/EN 2GL 230VAC 5 **8109130000**
**Note**
| Pot|g! 0
**Accessories End bracket**
**Type Width Qty. Order No.** Dark beige Wemid EWK 1 9 mm 50 **0206160000** Dark beige Wemid EW 35 8.5 mm 50 **0383560000**
- Slide link is opened
- Auxiliary circuit is **not earthed**
- **No** earth fault
- Display illuminated green and red with reduced intensity
- Disconnected earth connection -> When measuring insulation resistance with voltages greater than UNom, the earth connection must be disconnected.
## **Operational malfunction**
**==> picture [26 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
SAKA 10<br>**----- End of picture text -----**<br>
**==> picture [31 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
| Got 0<br>**----- End of picture text -----**<br>
- Slide link is opened
- Auxiliary circuit is **not earthed**
- **Earth fault**
(see assortment in catalogue 7)
**For detailed information on other accessories and applications, refer to the „Accessories“ section**
Width with AP = 27 mm
- Display is illuminated red
**C.8**
**Contents**
**D**
## SAK-Series for special applications
|**SAK-Series for special applications**|**Modular terminals for high-temperature applications**<br>TS 32 / Ceramic<br>D.2|
|---|---|
||**Modular terminals for nuclear power stations**<br>Overview<br>D.4<br>TS 32 / EP<br>D.6|
**D.1**
**Modular terminals for high-temperature applications**
**D**
## **TS 32 / Ceramic**
## **SAKK 4 Sn**
## **SAKK 4 Ni 4 mm²**
**4 mm² SAKK 4 Ni 4 mm² Nickel coating for high-temperature applications - max. 750°C for 3 hours**
**Tin Plated for high continuous temperatures - max. 250 °C**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS35x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [507 x 240] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|8 x 40 x 53|8 x 40 x 53|
|max. current / max. cond. cross-section|A/mm²|41 / 6|41 / 6|
|a|a)|o——__4__|
|Max. clamping range|mm²|0.33...6|0.33...6|
|Technical data|IEC 60947-7-1|Ex e II|T|II 2 G D|IEC 60947-7-1|Ex e II|T|II 2 G D|
|Rated data|IEC|UL|CSA|EN 60079-7|IEC|UL|CSA|EN 60079-7|
|Rated voltage|V|800|600|275|800|600|275|
|Rated current|A|32|30|28|32|30|28|
|Rated cross-section|mm²|4|4|4|4|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A4 / 5VB|A4 / 5VB|
|Approvals|# a|SIRA 03ATEX3425 U|# a|SIRA 03ATEX3425 U|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...6|0.5...6|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...4|0.5...4 / 0.5...4|
|Tightening torque range (clamping screw)|0.5...1.0 Nm (M 3)|0.5...1.0 Nm (M 3)|
|Stripping length / Blade size|mm/-|10 / 0.6 x 3.5 mm|10 / 0.6 x 3.5 mm|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|mm²|0.5...1.5|
|flexible / Stranded wire with end ferrules|mm²|0.5...1.5 / 0.5...1.5|
|Note|Do not use mechanical or electrical torque screwdrivers for fastening the|Do not use mechanical or electrical torque screwdrivers for fastening the|
|conductor.|conductor.|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|white|SAKK 4 KER/WS|25|1598080000|SAKK 4|25|9502600000|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
**Version Note**
**==> picture [503 x 126] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|white|SAKK 4 KER/WS|25|1598080000|SAKK 4|25|9502600000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|QL 2 SAKK 4 TIN|32 A|100|9509420000|QL 2 SAKK 4|32 A|100|9502540000|
|3-pole|QL 3 SAKK 4 TIN|32 A|100|9509430000|QL 3 SAKK 4|32 A|100|9502550000|
|4-pole|QL 4 SAKK 4 TIN|57 A|50|9509440000|QL 4 SAKK 4|32 A|50|9502560000|
|10-pole|QL 10 SAKK 4 TIN|41 A|20|9509450000|QL 10 SAKK 4|41 A|20|9502570000|
|Connecting sleeve|VH 13.5 SAKK4|100|9509460000|VH 13.5 SAKK 4|100|9502580000|
|Mounting screw|KISC M3X20.5/10 EK4|100|0303000000|KISC M3X20.5/10 EK4|100|0303000000|
|End plate / Partition plate|Width|Width|
|white|AP SAKK4/10 KER/WS|3 mm|10|9502630000|AP SAKK4/10 KER/WS|3 mm|10|9502630000|
**----- End of picture text -----**<br>
## **Accessories**
(see assortment in catalogue 7)
**For detailed information on other accessories and applications, refer to the „Accessories“ section**
Twin wire-end ferrules ZH 0.5 - ZH 2.5 can be used. End bracket MEW 1/32 order no. 0445600000; locking pin SST3 order no. 0152700000
End Barrier MEW 1/32 order no. 0445600000; Locking pin SST3 order no. 0152700000
**D.2**
**Modular terminals for high-temperature applications**
|**Tin Plated for high continuous temperatures**<br>**- max. 250 °C**<br>**SAKK 10 Sn**<br>**10 mm²**|**Tin Plated for high continuous temperatures**<br>**- max. 250 °C**<br>**SAKK 10 Sn**<br>**10 mm²**|**Tin Plated for high continuous temperatures**<br>**- max. 250 °C**<br>**SAKK 10 Sn**<br>**10 mm²**|**Tin Plated for high continuous temperatures**<br>**- max. 250 °C**<br>**SAKK 10 Sn**<br>**10 mm²**|**Tin Plated for high continuous temperatures**<br>**- max. 250 °C**<br>**SAKK 10 Sn**<br>**10 mm²**|**Nickel coating for high-temperature applica-**<br>**tions - max. 750°C for 3 hours**<br>**SAKK 10 Ni**<br>**10 mm²**|**Nickel coating for high-temperature applica-**<br>**tions - max. 750°C for 3 hours**<br>**SAKK 10 Ni**<br>**10 mm²**|**Nickel coating for high-temperature applica-**<br>**tions - max. 750°C for 3 hours**<br>**SAKK 10 Ni**<br>**10 mm²**|**Nickel coating for high-temperature applica-**<br>**tions - max. 750°C for 3 hours**<br>**SAKK 10 Ni**<br>**10 mm²**|**Nickel coating for high-temperature applica-**<br>**tions - max. 750°C for 3 hours**<br>**SAKK 10 Ni**<br>**10 mm²**|
|---|---|---|---|---|---|---|---|---|---|
||ii|ii|ii|ii|ii|ii|ii|ii|ii|
|11.5 x 40 x 53|11.5 x 40 x 53||||11.5 x 40 x 53|11.5 x 40 x 53||||
|**76 / 16**<br>**1.5...16**|**76 / 16**<br>**1.5...16**<br>~~o~~<br>~~$5~~<br>~~o_o~~|||||||||
|IEC 60947-7-1|||Ex e IIT II 2 G D||IEC 60947-7-1|||Ex e IIT II 2 G D||
|**IEC**|**UL**|**CSA**||**EN 60079-7**|**IEC**|**UL**|**CSA**||**EN 60079-7**|
|800<br>57|600<br>55|||275<br>50|800<br>57|600<br>55|||275<br>50|
|10||||10|10||||10|
||8 / 3|||||8 / 3||||
||B6 / 5VB|B6 / 5VB||||B6 / 5VB|B6 / 5VB|||
|#a|||SIRA 03ATEX3425 U|SIRA 03ATEX3425 U|#a|||SIRA 03ATEX3425 U|SIRA 03ATEX3425 U|
|**Rated connection**|||||**Rated connection**|||||
|1.5...16 / 1.5...16|||||1.5...16 / 1.5...16|||||
|1.5...16 / 1.5...10|||||1.5...16 / 1.5...10|||||
|2.0...4.0 Nm(M 4)|||||2.0...4.0 Nm(M 4)|||||
|12 / 1.0 x 5.5 mm|||||12 / 1.0 x 5.5 mm|||||
|||||||||||
|||||||||||
|||||||||||
|Do not use mechanical or electrical torque screwdrivers for fastening the|||||Do not use mechanical or electrical torque screwdrivers for fastening the|||||
|conductor.|||||conductor.|||||
|||||||||||
|**Type**|||**Qty.**|**Order No.**|**Type**|||**Qty.**|**Order No.**|
|SAKK 10 KER/WS|||25|**1598090000**|SAKK 10|||25|**9502610000**|
|||||||||||
|||||||||||
|**Type**|**current**||**Qty.**|**Order No.**|**Type**|**current**||**Qty.**|**Order No.**|
|QL 2 SAKK 10 TIN|QL 2 SAKK 10 TIN||100|**9509470000**|QL 2 SAKK 10||57 A|100|**9502650000**|
|QL 3 SAKK 10 TIN|QL 3 SAKK 10 TIN||50|**9509480000**|QL 3 SAKK 10||57 A|50|**9502660000**|
|QL 4 SAKK 10 TIN|QL 4 SAKK 10 TIN||50|**9509490000**|QL 4 SAKK 10||57 A|50|**9502670000**|
|QL 10 SAKK 10 TIN|||20|**9509500000**|QL 10 SAKK 10||57 A|20|**9502680000**|
|VH 12.5 SAKK10|||50|**9509510000**|VH 12.5 SAKK10|||50|**9502690000**|
|KISC M3X20.5/10 EK4|||100|**0303000000**|KISC M3X20.5/10 EK4|||100|**0303000000**|
||**Width**|||||**Width**||||
|AP SAKK4/10 KER/WS||3 mm|10|**9502630000**|AP SAKK4/10 KER/WS||3 mm|10|**9502630000**|
End barrier MEW 1/32 order no. 0445600000; Locking pin SST3 order no. 0152700000
End barrier MEW 1/32 order no. 0445600000; Locking pin SST3 order no. 0152700000
**D**
**D.3**
**Modular terminals for nuclear power stations**
**D**
## Terminal Blocks for the Containment Areas of Nuclear Power Generating Stations
**D.4**
**Modular terminals for nuclear power stations**
**D**
High standards are set for products used in containment areas of nuclear power generating stations. Years of radioactive radiation must not lead to failure. Signals must be transmitted faultlessly in the case of accidents, for example, steam escaping after a coolant pipe burst.
In particular, steam enveloping the terminal blocks could lead to problems. Unsuitable terminal blocks cause leakage currents, which lead to signal distortions. That is why only products which have been approved in accordance with IEEE Class 1 E are allowed to be installed in containment areas.
The special feature of the tests carried out using Weidmüller‘s terminal blocks is that not only was the insulation resistance measured following an accident simulation, but that the leakage current was recorded during the LOCA test (Loss of Coolant Accident).
Weidmüller also offers for these applications a choice of products made from the special epoxy resin material EP with inorganic filler, which meets the demands for high standards.
The comprehensive test results produced by the Wyle Laboratories enable the regulatory body to judge Weidmüller‘s products for containment areas Class 1 E (accident simulation test profile 4) and for general use (accident simulation test profile 1) in nuclear generating stations.
## **Basis: IEEE 323 – 1983**
“Qualifying class 1 E Equipment for Nuclear Power Generating Stations”
**IEE 344 – 1987**
“Recommended Practices for Seismic Qualification of Class 1 E Equipment for Nuclear Power Generating Stations”
**Agency:** Wyle Laboratories, Huntsville, Alabama, USA
**Period:** 1992 – 1993
## **6. Functional Test/Final Values**
The basis for the qualification statement are the standards laid down in the IEEE that comprise the following product cycles:
- Volume resistance
- Optical inspection
## **1. Functional Test/Initial Values**
As well as the special terminal blocks for the containment areas, which correspond to the standards according to Class 1 E, Weidmüller has subjected a range of standard terminal blocks to intensive tests in accordance with test profile 1. They all fully meet the demands set for terminal blocks for outside of restricted areas.
- Insulation resistance
- Volume resistances
## **2. Radioactive Aging**
- Total dose: 220 Mrad • Dose rate: 1 Mrad/h
- Volume resistance after contamination
## **3. Thermal aging equivelant to**
## **Accident Simulation Test Profile 1 Typical PWR Outside Containment Simulation**
## **40 years of operation at ambient temperature**
- 32 °C = 90 °F outside of
- containment area
During the 4-hour test, saturated steam is fed to the temperature control. This simulation is carried out at atmospheric pressure.
- 65 °C = 150 °F within the
- containment area
- Accelerated aging
## **Accident Simulation Test Profile 4 Typical PWR Inside Containment Simulation**
- Insulation resistance after contamination
## **4. Earthquake Simulation**
- 5 OBE, 1 SSE test in 3 axses
- Monitoring of the electrical functions
During the 29-hour test, saturated steam is fed to the temperature control. In the period from the 3rd to 24th hour, the test circuit that is coated with a chemical spray is alternatively coated with a deminaralizing spray. This simulation is carried out at an increased pressure of a maximum of 4500 hPa (4.5 bar).
## **5. Accident Simulation**
- Inside and outside of the
containment area
- Monitoring of leakage currents for different applications during the accident simulation
- Insulation resistance after contamination
**==> picture [319 x 259] intentionally omitted <==**
**----- Start of picture text -----**<br>
°C<br>Accident Simulation Test Profile 1<br>93<br>(Outside Containment Simulation)<br>66<br>°C 1 2 3 4 h<br>180 Accident Simulation Test Profile 4<br>(Inside Containment Simulation)<br>150<br>140<br>h<br>hPa<br>4500<br>3600<br>2400<br>Spray<br>3 11 24 29 h<br>**----- End of picture text -----**<br>
**D.5**
**Modular terminals for nuclear power stations**
**4 mm² SAKH 6**
**10 mm²**
**D**
## **TS 32 / EP**
**SAKH 4**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS35x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [455 x 168] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|6.5 x 40 x 51.5|14 x 57 x 76.5|
|max. current / max. cond. cross-section|A/mm²|41 / 6|76 / 16|
|o——__4|0|
|Max. clamping range|mm²|0.13...6|0.5...16|
|Technical data|IEC 60947-7-1|Ex e II|T|II 2 G D|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|EN 60079-7|IEC|UL|CSA|
|Rated voltage|V|800|550|1000|
|Rated current|A|32|28|57|
|Rated cross-section|mm²|4|4|10|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A4 / V-0|B6 / V-0|
|Approvals|#|KEMA 97ATEX1798 U|#|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...6 / 0.5...4|0.5...16 / 10...16|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...4|0.5...10 / 0.5...10|
|Tightening torque range (clamping screw)|0.5...1.0 Nm (M 3)|1.2...2.4 Nm (M 4)(M 4)M 4))|
|Stripping length / Blade size|mm/-|12 / 0.6 x 3.5 mm|12 / 1.0 x 5.5 mm|
|Note|When using the twin wire-end ferrules ZH 0.5 - ZH 2.5 without a partition|Twin wire-end ferrules ZH 75 - ZH 6 can be used.|
**----- End of picture text -----**<br>
## **Technical data**
**Rated connection** 0.5...16 / 10...16 0.5...10 / 0.5...10 1.2...2.4 Nm (M 4)(M 4)M 4)) 12 / 1.0 x 5.5 mm Twin wire-end ferrules ZH 75 - ZH 6 can be used.
When using the twin wire-end ferrules ZH 0.5 - ZH 2.5 without a partition wall, the rated voltage is 690 V.
## **Ordering data**
**==> picture [155 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|SAK 4 EP/SW|100|0128300000|
|SAK 4 CUN/EP/SW|100|0168800000|
**----- End of picture text -----**<br>
**Version Note**
**==> picture [329 x 145] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|black|SAK 4 EP/SW|100|0128300000|
|Black|SAK 4 CUN/EP/SW|100|0168800000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|
|2-pole|Q 2 SAK4|41 A|50|0336700000|
|3-pole|Q 3 SAK4|41 A|50|0336800000|
|4-pole|Q 4 SAK4|41 A|50|0336900000|
|10-pole|Q 10 SAK4|41 A|20|0368800000|
|Testing / Checking|Width|
|Test plug|PS 4 F.STB 4|7.6 mm|20|0299600000|
|Socket|STB 14/D5/2.3/M3 SAK2.5|50|0168600000|
|End plate / Partition plate|
|black|TW SAK4-10 EP/SW|2.5 mm|20|0130100000|
**----- End of picture text -----**<br>
## **Accessories**
**==> picture [155 x 154] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Type|Qty.|Order No.|
|SAKH 6 EP/SW|50|0126600000|
|Type|Qty.|Order No.|
|Width|
|AP SAKH6/10 EP/SW|4 mm|20|0131700000|
**----- End of picture text -----**<br>
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and ap-** End bracket from EP: 0693060000 EWK 1PPS/SW. **plications, refer to the „Accessories“ section**
DEK 5/5
End bracket from EP: 0693060000 EWK 1PPS/SW.
**D.6**
**Modular terminals for nuclear power stations**
**SAKH 10**
**10 mm² SAKH 35**
**35 mm²**
|14 x 57 x 76.5|||||18 x 125 x 90|||||
|---|---|---|---|---|---|---|---|---|---|
|**57 / 16**|**150 / 50**<br>o————_o|||||o————_o||||
|**1.5...16**|||||**4...50**|||||
|IEC 60947-7-1|||||IEC 60947-7-1|||||
|**IEC**|**UL**<br>**CSA**||||**IEC**|**UL**<br>**CSA**||||
|1000|||||1000|||||
|57|||||125|||||
|10|||||35|||||
||8 / 3|||||8 / 3||||
||B6 / V-0|||||B8 / V-0||||
|#|||||#|||||
|**Rated connection**|||||**Rated connection**|||||
|1.5...16 16|||||4...16 / 16...50|||||
|2.5...10 / 1...10|||||4...35 / 4...35|||||
|2.0...4.0 Nm(M 4)|||||4.0...5.0 Nm(M 6)|||||
|12 / 1.0 x 5.5 mm|||||18 / 6.5 x 1.2 mm|||||
|The tightening torque is 2 Nm when connecting AWG 6/7 conductors.|The tightening torque is 2 Nm when connecting AWG 6/7 conductors.|||The tightening torque is 2 Nm when connecting AWG 6/7 conductors.<br>The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stran-||
||||||ded conductors.|||||
|||||||||||
|**Type**||**Qty.**|||**Order No.**<br>**Type**||**Qty.**||**Order No.**|
|SAKH 10 EP/SW||50|||**0126700000**<br>SAKH 35 EP/SW||20||**1596240000**|
|SAKH 10 CUN/EP/SW||50|||**1104700000**|||||
|||||||||||
|||||||||||
|**Type**||**Qty.**|||**Order No.**<br>**Type**||**Qty.**||**Order No.**|
|**Type**||**Qty.**<br>**Order No.**|
|---|---|---|
|SAKH 10 EP/SW|SAKH 10 EP/SW|50<br>**0126700000**|
|SAKH 10 CUN/EP/SW|SAKH 10 CUN/EP/SW|50<br>**1104700000**|
||||
||||
|**Type**||**Qty.**<br>**Order No.**|
||||
||||
||||
||||
||||
||||
||||
|||**Width**|
|AP SAKH6/10 EP/SW||4 mm<br>20<br>**0131700000**|
**D**
DEK 5/5 DEK 5/6,5 End bracket from EP: 0693060000 EWK 1PPS/SW. End bracket from EP: 0693060000 EWK 1PPS/SW.
**D.7**
**Modular terminals for nuclear power stations**
**KMVF RE 6.3 EP/SW**
**2.5 mm²**
**D**
## **TS 32 / EP**
## **KMVF LI 6.3 EP/SW**
## **2.5 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS35x7.5|mm|
|max. current / max. cond. cross-sectionMax. clamping range|A/mm²mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [504 x 174] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|6 x 70 x 54|6 x 70 x 54|
|6,3|6,3|6,3|6,3|
|max. current / max. cond. cross-sectionMax. clamping range|A/mm²mm²|20 /|LJ|20 / ...|LJ|
|Technical data|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|800|800|
|Rated current|A|16|16|
|Rated cross-section|mm²|2.5|2.5|
|Rated impulse voltage / Pollution severity|kV/-|8 / 3|8 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|/ V-0|/ V-0|
|Approvals|#|#|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...2.5|0.5...2.5|
|flexible / Stranded wire with end ferrules|mm²|0.5...2.5 / 0.5...2.5|0.5...2.5 / 0.5...2.5|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|Note|250 V rated voltage for standard straight alignment and 800 V rated vol-|250 V rated voltage for standard straight alignment and 800 V rated vol-|
|tage for staggered alignment with alternating KMVF LI and KMVF RE.|tage for staggered alignment with alternating KMVF LI and KMVF RE.|
**----- End of picture text -----**<br>
## **Technical data**
**==> picture [156 x 52] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|250 V rated voltage for standard straight alignment and 800 V rated vol-|
|tage for staggered alignment with alternating KMVF LI and KMVF RE.|
|Type|Qty.|Order No.|
|KMVF LI 6.3 EP/SW|50|0249100000|
**----- End of picture text -----**<br>
## **Ordering data**
**==> picture [155 x 71] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|KMVF RE 6.3 EP/SW|50|0249200000|
|Type|Qty.|Order No.|
**----- End of picture text -----**<br>
**Version Note**
**==> picture [159 x 145] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|black|
|Black|
|Note|
|Accessories|
|Screwable cross-connection|
|2-pole|
|(ans|3-pole|
|Bag|
|Ban|4-pole|
|10-pole|
|Testing / Checking|
|Test plug|
|Socket|
|End plate / Partition plate|
|black|
**----- End of picture text -----**<br>
## **Accessories**
**Type Qty. Order No.**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
**D.8**
**Modular terminals for nuclear power stations**
**D**
**==> picture [505 x 486] intentionally omitted <==**
**----- Start of picture text -----**<br>
KMVT LI 2.4 EP/SW 0.5 mm² KMVT RE 2.4 EP/SW 0.5 mm² PPT/35 6 mm²<br>6 x 70 x 62 6 x 70 x 62 15 x 138 x 77<br>2,4 2,4 2,4 2,4<br> / LJ / LJ 30 / 10 o——43——_ [—o] +#<br>... ... 0.5...10<br>IEC 60947-7-1<br>IEC UL CSA IEC UL CSA IEC UL CSA<br>800 800 1500<br>12 12 30<br>0.5 0.5 6<br>8 / 3 8 / 3 15 / 3<br> / V-0 / V-0 / V-0<br># # #<br>Rated connection Rated connection Rated connection<br>0.5...2.5 0.5...2.5 0.5...10 / 0.5...10<br>0.5...2.5 / 0.5...2.5 0.5...2.5 / 0.5...2.5 1.5...6 / 1.5...4<br>12 /<br>250 V rated voltage for standard straight alignment and 800 V rated vol- 250 V rated voltage for standard straight alignment and 800 V rated vol-<br>tage for staggered alignment with alternating KMVT LI and KMVT RE. tage for staggered alignment with alternating KMVT LI and KMVT RE.<br>Type Qty. Order No. Type Qty. Order No. Type Qty. Order No.<br>KMVT LI 2.4 EP/SW 50 0249300000 KMVT RE 2.4 EP/SW 50 0249400000 PPT/35 10 3835020000<br>Type Qty. Order No. Type Qty. Order No. Type Qty. Order No.<br>Width<br>PS 4 F.STB 4 7.6 mm 20 0299600000<br>STB 17/D6/4/M4 SAKC10 50 0147100000<br>AP PPT/35 3 mm 10 3835120000<br>**----- End of picture text -----**<br>
**6 mm²**
DEK 5/5
DEK 5/5
DEK 5/5 The isolating plug (3835360000) may only be pulled out with the removal tool (3835260000). Insulated mounting rail (0514300000).
**D.9**
**D**
**D.10**
**Contents**
## AKZ-Series TS 15
## **AKZ-Series TS 15**
## **Mini Modular Terminals**
|**Mini Modular Terminals**||
|---|---|
|Feed-through terminal / Disconnect-test terminal TS 15 / PA|E.2|
|Modular PE terminals TS 15 / PA|E.4|
|Fuse terminals TS 15 / PA|E.6|
|With push-on connection TS 15 / PA|E.8|
|With solder connection TS 15 / PA|E.10|
|With solder connection TS 15 / KrG|E.12|
|With Termi-Point / Wire-Wrap connection TS 15 / PA|E.13|
**E**
**E.1**
**Mini modular terminals**
**AKZ 2.5**
**Feed-through terminal**
**E**
## **Feed-through terminal Disconnect-test terminal TS 15 / PA**
## **AKZ 1.5**
## **1.5 mm²**
## **Feed-through terminal**
## **2.5 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS35x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [335 x 181] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|5.1 x 24.8 x 25|5.1 x 25.5 x 26.5|
|24 / 2.5|32 / 4|
|o—__|Is|ob4|
|0.21...2.5|0.13...4|
|IEC 60947-7-1|Ex e II|T|II 2 G D|IEC 60947-7-1|Ex e II|T|II 2 G D|
|IEC|UL|CSA|EN 60079-7|IEC|UL|CSA|EN 60079-7|
|250|150|300|176|250|300|300|176|
|17.5|15|10|10|24|10|10|15|
|1.5|AWG 22...14|AWG 24...16|1.5|2.5|AWG 22...12|AWG 26...10|2.5|
|4 / 3|4 / 3|
|A1 / V2|A3 / V2|
|r # a|SIRA 02ATEX3001 U|r # a|SIRA 02ATEX3001 U|
|Rated connection|Rated connection|
|0.5...2.5 / 1.5...1.5|0.5...4 / 1.5...2.5|
|0.5...1.5 / 0.5...1.5|0.5...2.5 / 0.5...2.5|
|0.4...0.6 Nm (M 2.5)|0.4...0.6 Nm (M 2.5)|
|7 / 3.0 x 0.5 mm|7 / 3.0 x 0.5 mm|
|0.5...1|0.5...1.5|
|0.5...1 / 0.5...0.75|0.5...1.5 / 0.5...1.5|
**----- End of picture text -----**<br>
## **Technical data**
**==> picture [159 x 178] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Rated data|
|Rated voltage|V|
|Rated current|A|
|Rated cross-section|mm²|
|Rated impulse voltage / Pollution severity|kV/-|
|Gauge to IEC 60947-1 / UL94 Flammability class|
|Approvals|
|Clamped conductors (H05V/H07V)|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Note|
|Ordering datag data data|
|Version|
**----- End of picture text -----**<br>
## **Ordering datag data data**
**==> picture [160 x 58] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|AKZ 1.5|100|0340460000|
|AKZ 1.5 BL|100|0340480000|
|AKZ 1.5 order Nos 0340460000 and 0340480000 made from PA with V2|
|flammability rating to UL 94|
**----- End of picture text -----**<br>
**==> picture [160 x 58] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|AKZ 2.5|100|0697160000|
|AKZ 2.5 BL|100|0697180000|
|AKZ 2.5 order Nos 0697160000 and 0697180000 made from PA with V2|
|flammability rating to UL 94|
**----- End of picture text -----**<br>
Dark beige Wemid (PA) Blue Wemid (PA) beige (PA) Blue (PA) 2-polepoleole 3-polepoleole 4-polepoleole 10-polepoleole beigegee Dark beige Wemidge Wemide Wemid Blue Wemid Dark beige Wemidge Wemide Wemid Blue Wemid Small partitionpartitionartition Dark beige Wemidge Wemide Wemid Test plugpluglugg Socket
**==> picture [503 x 200] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Note|AKZ 1.5 order Nos 0340460000 and 0340480000 made from PA with V2|AKZ 2.5 order Nos 0697160000 and 0697180000 made from PA with V2|
|flammability rating to UL 94|flammability rating to UL 94|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-polepoleole|Q 2 AKZ1.5|24 A|50|0368200000|Q 2 AKZ1.5|24 A|50|0368200000|
|3-polepoleole|Q 3 AKZ1.5|24 A|50|0368300000|Q 3 AKZ1.5|24 A|50|0368300000|
|4-polepoleole|Q 4 AKZ1.5|24 A|50|0368400000|Q 4 AKZ1.5|24 A|50|0368400000|
|10-polepoleole|Q 10 AKZ1.5|24 A|20|0368500000|Q 10 AKZ1.5|24 A|20|0368500000|
|End plate / Partition plate|Width|Width|
|beigegee|
|Dark beige Wemidge Wemide Wemid|AP AKZ1.5|1.5 mm|50|0340560000|AP AKZ2.5|2.5 mm|50|0697360000|
|Blue Wemid|AP AKZ1.5 BL|1.5 mm|50|0340580000|AP AKZ2.5 BL|2.5 mm|50|0697380000|
|Dark beige Wemidge Wemide Wemid|TW AKZ2.5|0.5 mm|20|0318560000|
|Blue Wemid|TW AKZ2.5 BL|0.5 mm|20|0318580000|
|Small partition|
|Small partitionpartitionartition|
|End bracket|
|Dark beige Wemidge Wemide Wemid|EW 15|10 mm|50|0382860000|EW 15|10 mm|50|0382860000|
|Testing / Checking|
|Test plugpluglugg|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
**----- End of picture text -----**<br>
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
DEK 5/5
**E.2**
**Mini modular terminals**
**4 mm² SAKR 15**
**AKZ 4**
## **4 mm²**
**==> picture [331 x 472] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|6.1 x 27 x 30.5|6.5 x 42 x 31|
|41 / 6|/ 4|
|0.13...6|0.13...4|
|IEC 60947-7-1|Ex e II|T|II 2 G D|IEC 60947-7-1|
|IEC|UL|CSA|EN 60079-7|IEC|UL|CSA|
|400|300|300|275|400|300|300|
|32|27|10|21|10|10|10|
|4|AWG 22...12|AWG 24...12|4|4|AWG 22...12|AWG 26...12|
|6 / 3|6 / 3|
|A3 / V2|A3 / V2|
|r # i a|SIRA 02ATEX3001 U|# a|
|Rated connection|Rated connection|
|0.5...6 / 1.5...4|0.5...4 / 1.5...4|
|0.5...4 / 0.5...2.5|0.5...4 / 0.5...2.5|
|0.6...0.8 Nm (M 3)|0.5...1.0 Nm (M 3)|
|8 / 0.6 x 3.5 mm|8 / 0.6 x 3.5 mm|
|0.5...1.5|
|0.5...1.5 / 0.5...1.5|
|Tightening torque via the sockets is 0.5 - 0.7 Nm.|
|Type|Qty.|Order No.|Type|Qty.|Order No.|
|SAKR 15|100|0412760000|
|SAKR 15 2STB|100|0412860000|
|AKZ 4|100|0294360000|
|AKZ 4 BL|100|0294380000|
|AKZ 4 order no. 0294360000 and 0294380000 made of PA with flamma-|The ZH 0.5 - ZH 1.5 twin ferrules can be used.|
|bility class acc. to UL 94/V-2|
|Type|current|Qty.|Order No.|Type|Qty.|Order No.|
|Q 2 AKZ4|32 A|50|0336400000|
|Q 3 AKZ4|32 A|50|0336500000|
|Q 4 AKZ4|32 A|50|0336600000|
|Q 10 AKZ4|32 A|20|0368600000|
|Width|Width|
|AP SAKR BE|1.5 mm|20|0211360000|
|AP AKZ4|1.5 mm|20|0294460000|
|AP AKZ4 BL|1.5 mm|20|0294480000|
|TW AKZ4|0.5 mm|50|0348260000|
|TW AKZ4 BL|0.5 mm|50|0348280000|
|TSCH 4 AKZ4|6 mm|100|0363360000|
|EW 15|10 mm|50|0382860000|EW 15|10 mm|50|0382860000|
|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
**----- End of picture text -----**<br>
DEK 5/6
DEK 5/6,5 QB 25 blank, refer to „Accessories“ section. Note that max. conductor connection with QB = 2.5 mm².
**E**
**E.3**
**Mini modular terminals**
**2.5 mm² AKE 4 MS**
## **Modular PE terminals TS 15 / PA**
**AKE 2.5**
## **PE terminal**
## **PE terminal**
**4 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**E**
**==> picture [505 x 241] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|5.1 x 28 x 28|7 x 32 x 30|
|max. current / max. cond. cross-section|A/mm²|/ 4|/ 4|
|Max. clamping range|mm²|0.13...4|o————|PE|0.5...4|PE|
|Technical data|IEC 60947-7-2|Ex e II|T|II 2 G D|IEC 60947-7-2|
|Rated data|IEC|UL|CSA|EN 60079-7|IEC|UL|CSA|
|Rated cross-section|mm²|2.5|AWG 22...12|AWG 26...12|AWG 26...12|4|
|Rated voltage to adjacent terminal|V|250|
|Rated impulse withstand voltage to adjacent terminal|kV|4|
|Short-time withstand current|300 A (2.5 mm²)|480 A (4 mm²)|
|Pollution severity|3|3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|A3 / V2|
|Approvals|r # a|SIRA 02ATEX3001 U|#|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...4 / 1.5...2.5|0.5...4 / 1.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...2.5 / 0.5...2.5|0.5...4 / 0.5...4|
|Tightening torque range (clamping screw)|0.4...0.6 Nm (M 2.5)|0.8...1.6 Nm (M 3.5)|
|Tightening torque range (fixing screw)|0.4...0.6 Nm|0.8...1.6 Nm|
|Stripping length / Blade size|mm/-|7 / 3.0 x 0.5 mm|9 / 0.6 x 3.5 mm|
|Note|
|Ordering data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|green/yellow (PA)|AKE 2.5|100|1303360000|AKE 4 MS|50|0211200000|
|Note|
**----- End of picture text -----**<br>
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/5 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
**E.4**
**Mini modular terminals**
**E**
## **AKE 4 4 mm² PE terminal**
7 x 32 x 34.5 **/ 4 0.13...4** ~~2~~ PE IEC 60947-7-2 Ex e II T II 2 G D **IEC UL CSA EN 60079-7** 4 AWG 22...12 AWG 26...12 AWG 26...12 500 6 480 A (4 mm²) 3 A3 / V2 r # a SIRA 02ATEX3001 U **Rated connection** 0.5...4 / 1.5...4 0.5...4 / 0.5...2.5 0.5...1.0 Nm (M 3) 0.5...1.0 Nm 9 / 0.6 x 3.5 mm **Type Qty. Order No.** AKE 4 100 **0380260000**
DEK 5/6,5
**E.5**
**Mini modular terminals**
**ASK 1/15**
**4 mm²**
**E**
## **Fuse terminals TS 15 / PA**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS35x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
## **Technical data**
**==> picture [159 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Rated data|
|Rated voltage|V|
|Rated current|A|
|Rated cross-section|mm²|
|Rated impulse voltage / Pollution severity|kV/-|
|Gauge to IEC 60947-1 / UL94 Flammability class|
|Approvals|
|Clamped conductors (H05V/H07V)|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|2 conductors with same cross-section (H05V/H07V)|
|solid / stranded|-|
|flexible / Stranded wire with end ferrules|-|
|Note|
**----- End of picture text -----**<br>
## **Ordering data**
**Version Note**
Without LED **Note Accessories Screwable cross-connection** 2-pole 3-pole 4-pole
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags **For detailed information on other accessories and applications, refer to the „Accessories“ section**
**==> picture [119 x 155] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|8 x 58 x 34|
|6.3 / 4|
|0.13...4|
|IEC|UL|CSA|
|500|300|300|
|6.3|10|6.3|
|4|AWG 22...12|AWG 26...12|
|6 / 3|
|A3 / V2|
|r # a|
|Rated connection|
|0.5...4 / 1.5...4|
|0.5...4 / 0.5...4|
|0.5...1.0 Nm (M 3)|
|9 / 0.6 x 3.5 mm|
**----- End of picture text -----**<br>
**==> picture [158 x 125] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Note: max. conductor size = 2.5 mm² when using the cross-connection.|
|Twin wire-end ferrules ZH 0.5 - ZH 1.5 can be used.|
|Type|Qty.|Order No.|
|ASK 1/15|100|0376860000|
|Type|current|Qty.|Order No.|
|QB 2 WI RA8 IS|27 A|50|0461100000|
|QB 3 WI RA8 IS|27 A|50|0461200000|
|QB 4 WI RA8 IS|27 A|50|0461300000|
**----- End of picture text -----**<br>
DEK 5/6,5 Contact Sleeve order no. 0553300000; AP ASK 1 order no. 0380360000.
**E.6**
**E**
**E.7**
**Mini modular terminals**
**AKZ 4 SS SE 6.3/2.8**
**AKZ 4 SS WA 2*2.8**
**2.5 mm²**
**1 mm²**
**E**
## **with push-on connection TS 15 / PA**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm²
|Width/Length/height with TS35x7.5|mm|6 x 28.45 x 30.5|6 x 28.45 x 30.5|6 x 28.45 x 30.5||||||||6 x 28.45 x 30.5|6 x 28.45 x 30.5|||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|max. current / max. cond. cross-section<br>Max. clamping range|A/mm²<br>mm²|**16 /**||||6,3<br>2,8||||6,3<br>2,8||**8 / 1**<br>**0.2...1**|||2,8||2,8|
|**Technical data**||IEC 60947-7-1 / IEC 61210|||IEC 60947-7-1 / IEC 61210|||||||IEC 60947-7-1 / IEC 61210||IEC 60947-7-1 / IEC 61210||||
|**Rated data**|||**IEC**||**UL**||**CSA**|||||**IEC**||**UL**||**CSA**||
|Rated voltage|V||400||150||300|||||400||150||300||
|Rated current|A||8||10||10|||||8||10||10||
|Rated cross-section|mm²||2.5|AWG 22...12||AWG 24...12||||||1|AWG 22...12||AWG 24...12|||
|Rated impulse voltage / Pollution severity|kV/-||||6 / 3|||||||||6 / 3||||
|Gauge to IEC 60947-1 / UL94 Flammabilityclass|||||/ V2|||||||||/ V2||||
|Approvals|r# a|||||||||||r# a||||||
|**Clamped conductors(H05V/H07V)**||**Rated connection**||||||||||**Rated connection**||||||
|solid / stranded|mm²|||||||||||||||||
|flexible / Stranded wire with end ferrules|mm²|...4||||||||||||||||
|Tighteningtorque range(clampingscrew)||||||||||||||||||
|Strippinglength / Blade size|mm/-|||||||||||||||||
|**2 conductors with same cross-section(H05V/H07V)**||||||||||||||||||
|solid / stranded|-|||||||||||||||||
|flexible / Stranded wire with end ferrules|-|||||||||||||||||
|**Note**||Rated voltage is 400 V when insulation sleeves are used I max 20 A valid||||||||||||||||
## **Technical data**
Rated voltage is 400 V when insulation sleeves are used I max 20 A valid when used with 2 x F 6.3 or 4 x F 2.8.
## **Ordering data**
|**Version**||**Type**|**Qty.**<br>**Order No.**||**Type**|**Qty.**|**Order No.**|
|---|---|---|---|---|---|---|---|
|Slotted||AKZ 4 SS SE 6.3/2.8|100<br>**0324560000**|||||
|Not slit|||||AKZ 4 SS WA 2X2.8|100|**0362460000**|
|**Note**||||||||
|**Accessories**||||||||
|**Screwable cross-connection**||**Type**|**current**<br>**Qty.**<br>**Order No.**||**Type**|**current**<br>**Qty.**|**Order No.**|
|2-pole||Q 2 AKZ4SS|20 A<br>50<br>**0369000000**||Q 2 AKZ4SS|20 A<br>50|**0369000000**|
|3-pole||Q 3 AKZ4SS|20 A<br>50<br>**0369100000**||Q 3 AKZ4SS|20 A<br>50|**0369100000**|
|4-pole||Q 4 AKZ4SS|20 A<br>50<br>**0369200000**||Q 4 AKZ4SS|20 A<br>50|**0369200000**|
|10-pole||Q 10 AKZ4SS|20 A<br>20<br>**0369300000**||Q 10 AKZ4SS|20 A<br>20|**0369300000**|
|**Endplate / Partitionplate**|||**Width**|||**Width**||
|Dark beige Wemid||AP AKZ4|1.5 mm<br>20<br>**0294460000**||AP AKZ4|1.5 mm<br>20|**0294460000**|
|Dark beige Wemid||TW AKZ4|0.5 mm<br>50<br>**0348260000**||TW AKZ4|0.5 mm<br>50|**0348260000**|
|**Testing / Checking**||||||||
|Testplug||PS 2.3 RT|5.4 mm<br>20<br>**0180400000**||PS 2.3 RT|5.4 mm<br>20|**0180400000**|
|Socket||STB 8.5/D4/2.3/M2.5 AKZ|50<br>**0215700000**||STB 8.5/D4/2.3/M2.5 AKZ|50|**0215700000**|
|**Insulating sleeve**||||||||
|2,8||IH 2.8 DB|100<br>**0386060000**||IH 2.8 DB|100|**0386060000**|
|6,3||IH 6.3 WEM GE|100<br>**0386260000**|||||
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/6 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/6
**E.8**
**Mini modular terminals**
**AKZ 4 S WA 2*2.8**
**AKZ 4 SF SE 6.3/2.8**
**4 mm²**
## **4 mm²**
|6 x 27 x 30|||||2,8<br>2,8<br>6 x 27 x 30|2,8<br>2,8<br>6 x 27 x 30||||
|---|---|---|---|---|---|---|---|---|---|
|**8 /**||||||**8 / 4**|||6,3|
|**...**||||||**0.2...4**|||2,8|
|IEC 60947-7-1 / IEC 61210||IEC 60947-7-1 / IEC 61210||||IEC 60947-7-1 / IEC 61210|IEC 60947-7-1 / IEC 61210|||
|**IEC**||**UL**||**CSA**||**IEC**|**UL**|**CSA**||
|400||150||300||400||300||
|8||20||10||8||10||
|4|AWG 22...12||AWG 24...12|||4|AWG 24...12|||
|||6 / 3|||||6 / 3|||
|||A3 / V2|||||A3 / V2|||
|r# a||||||r#||||
|**Rated connection**||||||**Rated connection**||||
|0.5...4 / 1.5...4||||||0.5...4 / 1.5...4||||
|0.5...4 / 0.5...1||||||0.5...4 / 0.5...2.5||||
|0.6...0.8 Nm(M 3)||||||0.6...0.8 Nm(M 3)||||
|8 / 0.6 x 3.5 mm||||||8 / 0.6 x 3.5 mm||||
|**Type**|**Qty.**<br>**Order No.**||**Type**|**Qty.**<br>**Order No.**|
|---|---|---|---|---|
||||AKZ 4 SF SE 6.3/2.8|100<br>**0158760000**|
|AKZ 4 S WA 2X2.8|100<br>**0324460000**||||
||||||
||||||
|**Type**|**current**<br>**Qty.**<br>**Order No.**||**Type**|**current**<br>**Qty.**<br>**Order No.**|
|Q 2 AKZ4|32 A<br>50<br>**0336400000**||Q 2 AKZ4|32 A<br>50<br>**0336400000**|
|Q 3 AKZ4|32 A<br>50<br>**0336500000**||Q 3 AKZ4|32 A<br>50<br>**0336500000**|
|Q 4 AKZ4|32 A<br>50<br>**0336600000**||Q 4 AKZ4|32 A<br>50<br>**0336600000**|
|Q 10 AKZ4|32 A<br>20<br>**0368600000**||Q 10 AKZ4|32 A<br>20<br>**0368600000**|
||**Width**|||**Width**|
|AP AKZ4|1.5 mm<br>20<br>**0294460000**||AP AKZ4|1.5 mm<br>20<br>**0294460000**|
|TW AKZ4|0.5 mm<br>50<br>**0348260000**||TW AKZ4|0.5 mm<br>50<br>**0348260000**|
||||||
|PS 2.3 RT|5.4 mm<br>20<br>**0180400000**||PS 2.3 RT|5.4 mm<br>20<br>**0180400000**|
|STB 8.5/D4/2.3/M2.5 AKZ|50<br>**0215700000**||STB 8.5/D4/2.3/M2.5 AKZ|50<br>**0215700000**|
||||||
|IH 2.8 DB|100<br>**0386060000**||IH 2.8 DB|100<br>**0386060000**|
|**Type**|**current**<br>**Qty.**|**Order No.**|
|---|---|---|
|Q 2 AKZ4|32 A<br>50|**0336400000**|
|Q 3 AKZ4|32 A<br>50|**0336500000**|
|Q 4 AKZ4|32 A<br>50|**0336600000**|
|Q 10 AKZ4|32 A<br>20|**0368600000**|
||**Width**||
|AP AKZ4|1.5 mm<br>20|**0294460000**|
|TW AKZ4|0.5 mm<br>50|**0348260000**|
||||
|PS 2.3 RT|5.4 mm<br>20|**0180400000**|
|STB 8.5/D4/2.3/M2.5 AKZ|50|**0215700000**|
||||
|IH 2.8 DB|100|**0386060000**|
|IH 6.3 WEM GE|100|**0386260000**|
DEK 5/6
DEK 5/6
**E**
**E.9**
**Mini modular terminals**
**AKZ 1.5L VS**
**1.5 mm² AKZ 4 L**
**4 mm²**
**E**
## **with solder connection TS 15 / PA**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS35x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [503 x 438] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Width/Length/height with TS35x7.5|mm|5 x 34.4 x 25.5|6 x 35.6 x 30|
|max. current / max. cond. cross-section|A/mm²|16 / 2.5|17.5 / 4|
|>__ 3g|o——_4.__;|
|Max. clamping range|mm²|0.2...2.5|0.2...4|
|Technical data|IEC 60947-7-1 / IEC 60068-2-20|IEC 60947-7-1 / IEC 60068-2-20|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|250|150|250|300|300|
|Rated current|A|16|10|17.5|20|10|
|Rated cross-section|mm²|1.5|AWG 24...16|4|AWG 22...12|AWG 24...12|
|Rated impulse voltage / Pollution severity|kV/-|4 / 3|4 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A1 / V2|A3 / V2|
|Approvals|#|r # a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...2.5 / 0.5...1.5|0.5...4 / 1.5...4|
|flexible / Stranded wire with end ferrules|mm²|0.5...1.5 / 0.5...1.5|0.5...4 / 0.5...2.5|
|Tightening torque range (clamping screw)|0.4...0.6 Nm (M 2.5)|0.6...0.8 Nm (M 3)|
|Stripping length / Blade size|mm/-|7 / 3.0 x 0.5 mm|8 / 0.6 x 3.5 mm|
|Note|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|beige|AKZ 1.5L VS|100|0340160000|AKZ 4L SL VS|100|0334860000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|current|Qty.|Order No.|
|2-pole|Q 2 AKZ1.5|24 A|50|0368200000|Q 2 AKZ4|32 A|50|0336400000|
|3-pole|Q 3 AKZ1.5|24 A|50|0368300000|Q 3 AKZ4|32 A|50|0336500000|
|4-pole|Q 4 AKZ1.5|24 A|50|0368400000|Q 4 AKZ4|32 A|50|0336600000|
|10-pole|Q 10 AKZ1.5|24 A|20|0368500000|Q 10 AKZ4|32 A|20|0368600000|
|Switchable link|
|Switchable link|VL 2 AKZ4/DK4|50|0446700000|
|Connecting sleeve|VH 10/4/2.8 AKZ4|50|0446600000|
|Mounting screw|BFSC M2.5X14 SAKD2.5N|100|0266800000|
|Testing / Checking|Width|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|End plate / Partition plate|
|Dark beige Wemid|AP AKZ1.5W|1.5 mm|20|0329660000|AP AKZ4|1.5 mm|20|0294460000|
|Dark beige Wemid|TW AKZ4 HP/DBR/0.5|0.5 mm|50|0166800000|TW AKZ4|0.5 mm|50|0348260000|
|Small partition|
|Small partition|TSCH 4 AKZ4|6 mm|100|0363360000|
|Cover / warning label|
|Cover / warning label|AD 4 AKZ4|50|0303400000|
|Mounting screw (plastic)|BFSC M2.5X18 PA/RT|100|0303300000|
**----- End of picture text -----**<br>
## **Technical data**
## **Ordering datag data data**
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
DEK 5/6
**E.10**
**Mini modular terminals**
**1.5 mm² ADK 1**
## **AKZ 4 LL VS**
## **4 mm²**
|6 x 45.5 x 30|||6 x 22 x 36.5|
|---|---|---|---|
|**17.5 / 1.5**|~~a~~||**16 / 4**|
|**0.2...1.5**|||**0.13...4**|
|IEC 60947-7-1 / IEC 60068-2-20|IEC 60947-7-1 / IEC 60068-2-20|IEC 60947-7-1 / IEC 60068-2-20|||||||
|---|---|---|---|---|---|---|---|---|
|**IEC**|**UL**|**CSA**|||**IEC**|**UL**|**CSA**||
|250|300|300|||400|300|300||
|17.5|20|10|||16|10|15||
|1.5|AWG 22...12|AWG 24...12|AWG 24...12||4|AWG 26...12|AWG 26...12|AWG 26...12|
||4 / 3|4 / 3||||6 / 3|6 / 3||
||/ V2|/ V2||||A3 / V2|A3 / V2||
|r# a||||#|||||
|**Rated connection**||||**Rated connection**|||||
|0.5...1.5 / 0.5...1.5||||0.5...4 / 1.5...2.5|||||
|0.5...1.5 / 0.5...1.5||||0.5...4 / 0.5...2.5|||||
|||||0.5...0.8 Nm(M 3)|||||
|||||9 / 0.6 x 3.5 mm|9 / 0.6 x 3.5 mm||||
||||||||||
||||||||||
|**Type**|||**Qty.**<br>**Order No.**|**Type**||||**Qty.**<br>**Order No.**|
|AKZ 4 LL VS|||100<br>**0346460000**|ADK 1/1.5||||100<br>**0303860000**|
||||||||||
||||||||||
|**Type**|**current**||**Qty.**<br>**Order No.**|**Type**||||**Qty.**<br>**Order No.**|
|Q 2 AKZ4||32 A|50<br>**0336400000**||||||
|Q 3 AKZ4||32 A|50<br>**0336500000**||||||
|Q 4 AKZ4||32 A|50<br>**0336600000**||||||
|Q 10 AKZ4||32 A|20<br>**0368600000**||||||
||||||||||
|VL 2 AKZ4/DK4||32 A|50<br>**0446700000**||||||
|VH 10/4/2.8 AKZ4|||50<br>**0446600000**||||||
|BFSC M2.5X14 SAKD2.5N|BFSC M2.5X14 SAKD2.5N||100<br>**0266800000**||||||
|||**Width**|||||**Width**||
|PS 2.3 RT|5.4 mm||20<br>**0180400000**|PS 2.3 RT|PS 2.3 RT|5.4 mm||20<br>**0180400000**|
|STB 8.5/D4/2.3/M2.5 AKZ|||50<br>**0215700000**||||||
||||||||||
|AP AKZ4|1.5 mm||20<br>**0294460000**|AP ADK1|AP ADK1|||50<br>**0476260000**|
|TW AKZ4|0.5 mm||50<br>**0348260000**|TW ADK1 HP/DBR/0.5<br>0.5 mm||||50<br>**0442300000**|
||||||||||
|TSCH 4 AKZ4||6 mm|100<br>**0363360000**||||||
||||||||||
|AD 4 AKZ4|||50<br>**0303400000**||||||
|BFSC M2.5X18 PA/RT|BFSC M2.5X18 PA/RT||100<br>**0303300000**||||||
**E**
DEK 5/6
DEK 5/6
**E.11**
/
**Mini modular terminals**
**2.5 mm²**
**E**
## ; € nis
**with solder connection TS 15 / KrG**
## **AKZ 4 L KRG 4 mm² AKA 2.5**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [218 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Width/Length/height with TS35x7.5|mm|6 x 35.5 x 30|
|max. current / max. cond. cross-section|A/mm²|16 / 4|
|Max. clamping range|mm²|0.2...4|
**----- End of picture text -----**<br>
6 x 20 x 31 **20 / 2.5 0.13...2.5**
## **Technical data**
## IEC 60947-7-1 / IEC 60068-2-20
**==> picture [293 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|IEC|UL|CSA|IEC|UL|CSA|
|250|300|300|400|300|300|
|16|20|10|20|20|10|
|4|AWG 22...12|AWG 24...12|2.5|AWG 20...12|AWG 24...12|
|4 / 3|6 / 3|
|A3 / 5VA|A3 / V-0|
|r # a|r # a|
|Rated connection|Rated connection|
|0.5...4 / 1.5...4|0.5...2.5 / 1.5...2.5|
|0.5...4 / 0.5...2.5|0.5...2.5 / 0.5...1.5|
|0.6...0.8 Nm (M 3)|0.4...0.45 Nm (M 2.5)|
|8 / 0.6 x 3.5 mm|9 / 0.6 x 3.5 mm|
**----- End of picture text -----**<br>
**==> picture [159 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Rated data|
|Rated voltage|V|
|Rated current|A|
|Rated cross-section|mm²|
|Rated impulse voltage / Pollution severity|kV/-|
|Gauge to IEC 60947-1 / UL94 Flammability class|
|Approvals|
|Clamped conductors (H05V/H07V)|
|solid / stranded|mm²|
|flexible / Stranded wire with end ferrules|mm²|
|Tightening torque range (clamping screw)|
|Stripping length / Blade size|mm/-|
|Note|
**----- End of picture text -----**<br>
## **Ordering data**
**==> picture [155 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|AKZ 4L SL VS KRG|100|0334820000|
**----- End of picture text -----**<br>
**==> picture [155 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|AKA 2.5|100|0300720000|
|AKA 2.5 BL|100|0300770000|
**----- End of picture text -----**<br>
**Version Note**
**==> picture [503 x 257] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Medium yellow|AKZ 4L SL VS KRG|100|0334820000|AKA 2.5|100|0300720000|
|Blue|AKA 2.5 BL|100|0300770000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|Qty.|Order No.|
|2-pole|Q 2 AKZ4|32 A|50|0336400000|
|3-pole|Q 3 AKZ4|32 A|50|0336500000|
|4-pole|Q 4 AKZ4|32 A|50|0336600000|
|TH|10-pole|Q 10 AKZ4|32 A|20|0368600000|
|Switchable link|
|Switchable link|VL 2 AKZ4/DK4|50|0446700000|
|Connecting sleeve|VH 10/4/2.8 AKZ4|50|0446600000|
|Mounting screw|BFSC M2.5X14 SAKD2.5N|100|0266800000|
|Testing / Checking|Width|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
|End plate / Partition plate|Width|
|Medium yellow|AP AKA2.5|100|0162520000|
|Blue|AP AKA2.5 KRG/BL|50|0162570000|
|Dark beige Wemid|AP AKZ4|1.5 mm|20|0294460000|
|Dark beige Wemid|TW AKZ4|0.5 mm|50|0348260000|
|Small partition|
|Small partition|TSCH 4 AKZ4|6 mm|100|0363360000|
|Cover / warning label|
|Cover / warning label|AD 4 AKZ4|50|0303400000|
|Mounting screw (plastic)|BFSC M2.5X18 PA/RT|100|0303300000|
**----- End of picture text -----**<br>
## **Accessories**
**==> picture [159 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Marking systems|(see assortment in catalogue 7)|
|Marking tags|
|For detailed information on other accessories and ap-|
|plications, refer to the „Accessories“ section|
**----- End of picture text -----**<br>
DEK 5/6
DEK 5/6
**E.12**
**Mini modular terminals**
**AKZ 4 T**
**4 mm² AKZ 2.5K**
**E**
## **with Termi-Point / Wire-Wrap connection TS 15 / PA**
## **2.5 mm²**
In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed.
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Length/height with TS35x7.5|mm|
|max. current / max. cond. cross-section|A/mm²|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [332 x 28] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|6 x 27 x|5 x 29 x 46|
|1x1|
|10 / 4|8 / 5.26|
|0.2...4|o—_t__~|0.13...5.26|o—|_$_}|
**----- End of picture text -----**<br>
o— ~~_$_}~~
## **Technical data**
## IEC 60947-7-1
**==> picture [503 x 171] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|250|300|300|250|300|300|
|Rated current|A|10|10|10|8|10|10|
|Rated cross-section|mm²|4|AWG 26...14|AWG 24...12|2.5|AWG 22...12|AWG 26...10|
|Rated impulse voltage / Pollution severity|kV/-|4 / 3|4 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / V2|A2 / V2|
|Approvals|r # a|r # a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|solid / stranded|mm²|0.5...4 / 1.5...4|0.5...2.5 / 1.5...2.5|
|flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...2.5|0.5...2.5 / 0.5...2.5|
|Tightening torque range (clamping screw)|0.6...0.8 Nm (M 3)|0.4...0.6 Nm (M 2.5)|
|Stripping length / Blade size|mm/-|8 / 0.6 x 3.5 mm|7 / 3.0 x 0.5 mm|
|Note|
|Ordering datag data data|
|Version|Type|Qty.|Order No.|Type|Qty.|Order No.|
|rightghtht|AKZ 4 SW 1X1|100|0445860000|
|Vertical right|ht|AKZ 2.5 K SW U/V 1X1|100|0108960000|
**----- End of picture text -----**<br>
## **Ordering datag data data**
**Version Note**
**==> picture [503 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|rightghtht|AKZ 4 SW 1X1|100|0445860000|
|Vertical right|AKZ 2.5 K SW U/V 1X1|100|0108960000|
|Note|
|Accessories|
|Screwable cross-connection|Type|current|Qty.|Order No.|Type|Qty.|Order No.|
|2-pole|Q 2 AKZ4|32 A|50|0336400000|
|3-pole|Q 3 AKZ4|32 A|50|0336500000|
|4-pole|Q 4 AKZ4|32 A|50|0336600000|
|10-pole|Q 10 AKZ4|32 A|20|0368600000|
|End plate / Partition plate|Width|Width|
|Dark beige Wemid|AP AKZ4|1.5 mm|20|0294460000|AP AKZ2.5K|3 mm|50|0697260000|
|Dark beige Wemid|TW AKZ4|0.5 mm|50|0348260000|TW AKZ2.5|0.5 mm|20|0318560000|
|Small partition|
|Small partition|TSCH 4 AKZ4|6 mm|100|0363360000|
|Testing / Checking|
|Test plug|PS 2.3 RT|5.4 mm|20|0180400000|PS 2.3 RT|5.4 mm|20|0180400000|
|Socket|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|50|0215700000|
**----- End of picture text -----**<br>
## **Accessories**
**Marking systems** (see assortment in catalogue 7) Marking tags DEK 5/6 **For detailed information on other accessories and applications, refer to the „Accessories“ section**
DEK 5/5
**E.13**
**E**
**E.14**
**Contents**
**F**
## Multi-pole terminal strips
**Multi-pole terminal strips for direct mounting**
Screw connection F.2 Screw connection ATEX approval F.6
**F.1**
**Multi-pole terminal strips for direct mounting**
**MK 3/2...12**
**2.5 mm²**
**F**
**MK 2/12**
## **2.5 mm²**
## **Screw connection**
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Height/ø mounting hole|mm|
|Length / mounting dimensions|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
## **15 x 15 / 3.2** Refer to order data **0.2...4**
## **15 x 16.1 / 3.45**
**==> picture [465 x 419] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|Length / mounting dimensions|Refer to order data|Refer to order data|
|Max. clamping range|mm²|0.2...4|0.33...4|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|125|300|300|400|300|300|
|Rated current|A|24|10|10|24|25|25|
|Rated cross-section|mm²|2.5|AWG 24...12|AWG 24...12|2.5|AWG 22...12|AWG 22...12|
|Rated impulse voltage / Pollution severity|kV/-|3 / 3|6 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A2 / 5VA|A2 / 5VA|
|Approvals|r # a|r # i a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|Solid / Stranded|mm²|0.5...4 / 1.5...2.5|0.5...4 / 1.5...2.5|
|Flexible / Stranded wire with end ferrules|mm²|0.5...2.5 / 0.5...1.5|0.5...2.5 / 0.5...1.5|
|Tightening torque range (clamping screw)|0.4 Nm (M 2.5)|0.4...0.45 Nm (M 2.5)|
|Stripping length / Blade size|mm/-|5 / 0.6 x 3.5 mm|5 / 0.6 x 3.5 mm|
|Note|
|Ordering datag data data|
|Version|Type|Length|Mounting dimensions|Qty.|Order No.|Typeypee|Lengthgthth|Mounting dimensions|Qty.y..|
|2-pole|MK 3/2|17.4 mm|18.5 mm|100|
|3-pole|MK 3/3|26.5 mm|18.5 mm|50|
|4-pole|MK 3/4|35.75 mm|18.5 mm|50|
|5-pole|MK 3/5|45 mm|18.5 mm|50|
|6-pole|MK 3/6|54.25 mm|37.0 mm|50|
|7-pole|MK 3/7|63.5 mm|37.0 mm|50|
|8-pole|MK 3/8|72.75 mm|55.5 mm|25|
|9-pole|MK 3/9|82 mm|55.5 mm|25|
|10-pole|MK 3/10|91.25 mm|74.0 mm|20|
|12-pole|MK 2/12|86 mm|80.0 mm|50|0241260000|MK 3/12|110 mm|92.5 mm|20|
|14-pole|
|16-pole|
|Note|
|Accessories|
|Solder strip|Type|Width|Qty.|Order No.|Typeypee|Qty.y..|
|MF 2/12 1X2.8/1.6|75 mm|100|0241760000|
|Marking strips, printed|
|Printed|BSTB 28/12/6.35 U 1-12|50|0245700000|BSTB 28/12 MK U 1-12|50|
|BSTB 28/12/6.35 O 1-12|50|0278500000|BSTB 28/8 MK U 1-8|50|
|BSTB 28/6 MK U 1-6|50|
|Marking strips, unprinted|
|Unprinted|BSTO 28/12/6.35|50|0245600000|BSTO 28/12 MK|50|
**----- End of picture text -----**<br>
## **Technical data**
**Ordering datag data data Version**
**==> picture [155 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Typeypee|Lengthgthth|Mounting dimensions|Qty.y..|Order No.|
|MK 3/2|17.4 mm|18.5 mm|100|0273820000|
|MK 3/3|26.5 mm|18.5 mm|50|0273920000|
|MK 3/4|35.75 mm|18.5 mm|50|0274020000|
|MK 3/5|45 mm|18.5 mm|50|0274120000|
|MK 3/6|54.25 mm|37.0 mm|50|0274220000|
|MK 3/7|63.5 mm|37.0 mm|50|0274320000|
|MK 3/8|72.75 mm|55.5 mm|25|0274420000|
|MK 3/9|82 mm|55.5 mm|25|0274520000|
|MK 3/10|91.25 mm|74.0 mm|20|0274620000|
|MK 3/12|110 mm|92.5 mm|20|0243520000|
**----- End of picture text -----**<br>
## **Accessories**
**==> picture [155 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Typeypee|Qty.y..|Order No.|
|BSTB 28/12 MK U 1-12|50|0245900000|
|BSTB 28/8 MK U 1-8|50|0290200000|
|BSTB 28/6 MK U 1-6|50|0290000000|
|BSTO 28/12 MK|50|0245800000|
|BSTO 28/8 MK3/8|50|0284700000|
|BSTO 28/6 MK|50|0289500000|
|BSTO 28/4 MK3/4|50|0289300000|
**----- End of picture text -----**<br>
(see assortment in catalogue 7)
**For detailed information on other accessories and applications, refer to the „Accessories“ section.**
**F.2**
**Multi-pole terminal strips for direct mounting**
**F**
**MK 4/16**
**2.5 mm² MK 6/2...6/6**
**6 mm² MK 10/14**
**2.5 mm²**
**17 x 16 / 3.4 23 x 22 / 3.4** Refer to order data Refer to order data **0.2...4 0.33...6**
## **13.5 x 12 / 3.1** Refer to order data **0.21...4**
**==> picture [505 x 386] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|IEC 60947-7-1|IEC 60947-7-1|IEC 60947-7-1|
|IEC|UL|CSA|IEC|UL|CSA|IEC|UL|CSA|
|400|150|150|690|300|300|125|150|300|
|24|20|15|41|30|40|24|25|10|
|2.5|AWG 22...12|AWG 22...12|6|AWG 22...10|AWG 22...10|2.5|AWG 22...12|AWG 24...12|
|6 / 3|8 / 3|3 / 3|
|A2 / 5VA|A3 / 5VA|A2 / V2|
|?|r # a|r # i a|r # a|
|Rated connection|Rated connection|Rated connection|
|0.5...4 / 1.5...2.5|0.5...6 / 1.5...6|0.5...4 / 1.5...2.5|
|0.5...2.5 / 0.5...1.5|0.5...6 / 0.5...4|0.5...2.5 / 0.5...1.5|
|0.4...0.45 Nm (M 2.5)|1.2...2.0 Nm (M 4)|0.4...0.45 Nm (M 2.5)|
|5 / 0.6 x 3.5 mm|9 / 4.0 x 0.8 mm|6 / 0.6 x 3.5 mm|
|Type|Length|Mounting dimensions|Qty.|Order No.|Type|Length|Mounting dimensions|Qty.|Order No.|Type|Length|Mounting dimensions|Qty.|Order No.|
|MK 6/2|23.5 mm|50|0620420000|
|MK 6/3|36.5 mm|13.0 mm|50|0620320000|
|MK 6/4|49.5 mm|26.0 mm|20|0620220000|
|MK 6/6|75.5 mm|52.0 mm|20|0620120000|
|MK 10/14|88.5 mm|20|0370160000|
|MK 4/16|103 mm|85.5 mm|20|0244220000|
|Type|Breite|Qty.|Order No.|Type|Breite|Qty.|Order No.|Type|Breite|Qty.|Order No.|
|BSTB 28/16 MK U 1-16|50|0262200000|
|BSTB 28/16 MK O 1-16|50|0278700000|
|BSTO 28/16 MK 4/16|50|0262100000|
**----- End of picture text -----**<br>
**F.3**
**Multi-pole terminal strips for direct mounting**
**2.5 mm² KS 2...10**
**2.5 mm²**
**F**
## **Screw connection**
**MK 5/2 0.DE**
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Height/ø mounting hole|mm|
|Length / mounting dimensions|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**18 x 14 / 4.2** Refer to order data **0.2...4**
## **25 x 17.5 / 4.2** Refer to order data **0.2...4**
## **Technical data**
**==> picture [503 x 405] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|500|500|300|300|
|Rated current|A|24|24|20|25|
|Rated cross-section|mm²|2.5|2.5|AWG 22...12|AWG 24...12|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|6 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A2 / 5VA|A2 / 5VA|
|Approvals|r #|r # a|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|Solid / Stranded|mm²|0.5...4 / 1.5...2.5|0.5...4 / 1.5...2.5|
|Flexible / Stranded wire with end ferrules|mm²|0.5...2.5 / 0.5...1.5|0.5...2.5 / 0.5...1.5|
|Tightening torque range (clamping screw)|0.4 Nm (M 2.5)|0.5...0.7 Nm (M 3)|
|Stripping length / Blade size|mm/-|5 / 0.6 x 3.5 mm|8 / 4.0 x 0.8 mm|
|Note|
|Ordering datag data data|
|Version|Type|Length|Mounting dimensions|Qty.|Order No.|Type|Length|Mounting dimensions|Qty.|Order No.|
|2-pole|MK 5/2 O.DE|40 mm|32.0 mm|100|0243820000|KS 2 O.D2|42 mm|32.0 mm|100|0134420000|
|3-pole|
|4-pole|KS 4 O.D4|66 mm|56.0 mm|50|0140320000|
|6-pole|KS 6 O.D6|90 mm|80.0 mm|50|0140620000|
|10-pole|KS 10 O.D10|138 mm|128.0 mm|20|0141620000|
|12-pole|
|Note|
|Accessories|
|Lid / cover|Type|Width|Qty.|Order No.|Type|Width|Qty.|Order No.|
|D 2 MK5/2 PA/NA|18 mm|50|0244060000|D2 KS2 TP|25 mm|100|0134500000|
|D4 KS4 TP|48 mm|50|0140500000|
|D6 KS6 TP|72 mm|50|0140800000|
|D10 KS10 TP|120 mm|20|0141800000|
|Marking strips, printedg strips, printed strips, printedps, printeds, printedprintedrinted|
|Printed|ELSB 2 BEZ. 1-2|50|0143200000|
|ELSB 4 BEZ. 1-4|50|0143300000|
|ELSB 6 BEZ. 1-6|50|0143400000|
|ELSB 10 BEZ. 1-10|50|0143500000|
|Marking strips, unprintedg strips, unprinted strips, unprintedps, unprinteds, unprintedprintedrinted|
|Unprintedprintedrinted|ELSO 2 F.KS 2|50|0142800000|
|ELSO 4 F.KS 4|50|0142900000|
|ELSO 6 F.KS 6|50|0143000000|
|ELSO 10 F.KS 10|50|0143100000|
**----- End of picture text -----**<br>
## **Ordering datag data data**
**Note Accessories Lid / cover Marking strips, printedg strips, printed strips, printedps, printeds, printedprintedrinted** Printed **Marking strips, unprintedg strips, unprinted strips, unprintedps, unprinteds, unprintedprintedrinted** Unprintedprintedrinted (see assortment in catalogue 7) **For detailed information on other accessories and applications, refer to the „Accessories“ section.**
**F.4**
**Multi-pole terminal strips for direct mounting**
**BK 2...12**
**F**
## **4 mm²**
**22 x 20 / 3.4** Refer to order data
**0.33...4**
## IEC 60947-7-1
|**IEC**|**UL**|**CSA**|
|---|---|---|
|400|300|300|
|32|10|10|
|4|AWG 22...12|AWG 22...12|
||6 / 3||
||A3 / 5VA|A3 / 5VA|
# a
**Rated connection** 0.5...4 / 1.5...4 0.5...4 / 0.5...4 0.5...0.6 Nm (M 3) 8 / 4.0 x 0.8 mm
2 single-wire conductors with same cross-section (0.5...1.5 mm²) can be connected.
|**Type**|**Length **|**Mounting dimensions **|**Qty.**|**Order No.**|
|---|---|---|---|---|
|BK 2 CRN|20 mm||100|**0624720000**|
|BK 3 CRN|31 mm|11.0 mm|100|**0624920000**|
|BK 4 CRN|38 mm|18.0 mm|100|**0625120000**|
|BK 6 CRN|52 mm|32.0 mm|50|**0625220000**|
||||||
|BK 12 CRN|92 mm|72.5 mm|25|**0625320000**|
|**Type**|**Width**<br>**Qty.**<br>**Order No.**|
|---|---|
|||
|||
|||
|||
|||
|BSTB 28/2 BK U 1-2|50<br>**0203600000**|
|HASUE SAKR15LS|n.a.<br>**2038000000**|
|BSTB 28/4 BK U 1-4|50<br>**0197300000**|
|BSTB 28/6 BK U 1-6|50<br>**0197500000**|
|BSTB 28/12 BK U 1-12|50<br>**0198800000**|
|||
|BSTO 28/2 BK|50<br>**0203500000**|
|BSTO 28/3 BK|50<br>**0203700000**|
|BSTO 28/4 BK|50<br>**0197200000**|
|BSTO 28/6 BK|50<br>**0197400000**|
|BSTO 28/12 BK|50<br>**0198700000**|
**F.5**
**Multi-pole terminal strips for direct mounting**
**BK 2...12/E 4 mm² MK 3/2...12/E**
**F**
## **Screw connection ATEX approval**
**2.5 mm²**
**==> picture [159 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Width/Height/ø mounting hole|mm|
|Length / mounting dimensions|
|Max. clamping range|mm²|
**----- End of picture text -----**<br>
**==> picture [465 x 421] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|Width/Height/ø mounting hole|mm|22 x 20 / 3.4|15 x 16.1 / 3.45|
|Length / mounting dimensions|Refer to order data|Refer to order data|
|Max. clamping range|mm²|0.33...4|0.33...4|
|Technical data|IEC 60947-7-1|IEC 60947-7-1|
|Rated data|IEC|UL|CSA|IEC|UL|CSA|
|Rated voltage|V|400|400|
|Rated current|A|32|24|
|Rated cross-section|mm²|4|AWG 22...12|AWG 22...12|2.5|AWG 22...12|AWG 22...12|
|Rated impulse voltage / Pollution severity|kV/-|6 / 3|6 / 3|
|Gauge to IEC 60947-1 / UL94 Flammability class|A3 / 5VA|A2 / 5VA|
|Approvals|# a|#|
|Clamped conductors (H05V/H07V)|Rated connection|Rated connection|
|Solid / Stranded|mm²|0.5...4 / 1.5...4|0.5...4 / 1.5...2.5|
|Flexible / Stranded wire with end ferrules|mm²|0.5...4 / 0.5...4|0.5...2.5 / 0.5...1.5|
|Tightening torque range (clamping screw)|0.5...0.6 Nm (M 3)|0.4...0.45 Nm (M 2.5)|
|Stripping length / Blade size|mm/-|8 / 4.0 x 0.8 mm|5 / 0.6 x 3.5 mm|
|Note|2 single-wire conductors with same cross-section (0.5...1.5 mm²) can be|
|connected.|
|Ordering datag data data|
|Version|Typeypee|Lengthgthth|Mounting dimensions|Qty.y..|Order No.|Typeypee|Lengthgthth|Mounting dimensions|Qty.y..|
|2-pole|BK 2/E|20 mm|100|7906040000|MK 3/2/E|17.4 mm|18.5 mm|100|
|3-pole|BK 3/E|31 mm|11.0 mm|100|7906060000|MK 3/3/E|26.5 mm|18.5 mm|100|
|4-pole|BK 4/E|38 mm|18.0 mm|100|7906080000|MK 3/4/E|35.75 mm|18.5 mm|50|
|5-pole|MK 3/5/E|45 mm|18.5 mm|50|
|6-pole|BK 6/E|52 mm|32.0 mm|50|7906090000|MK 3/6/E|54.25 mm|37.0 mm|50|
|7-pole|MK 3/7/E|63.5 mm|37.0 mm|25|
|8-pole|MK 3/8/E|72.75 mm|55.5 mm|25|
|9-pole|MK 3/9/E|82 mm|55.5 mm|25|
|10-pole|MK 3/10/E|91.25 mm|74.0 mm|25|
|11-pole|MK 3/11/E|100.5 mm|74.0 mm|20|
|12-pole|BK 12/E|92 mm|72.5 mm|25|7906100000|MK 3/12/E|110 mm|92.5 mm|25|
|Note|
|Accessories|
|Marking strips, printed|Typeypee|Qty.y..|Order No.|Typeypee|Qty.y..|
|Printed|BSTB 28/2 BK U 1-2|50|0203600000|BSTB 28/12 MK U 1-12|50|
|HASUE SAKR15LS|n.a.|2038000000|BSTB 28/8 MK U 1-8|50|
|BSTB 28/4 BK U 1-4|50|0197300000|BSTB 28/6 MK U 1-6|50|
|BSTB 28/6 BK U 1-6|50|0197500000|
|BSTB 28/12 BK U 1-12|50|0198800000|
|Marking strips, unprinted|
|Unprinted|BSTO 28/2 BK|50|0203500000|BSTO 28/12 MK|50|
**----- End of picture text -----**<br>
## **Technical data**
**Ordering datag data data Version**
**==> picture [155 x 256] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Typeypee|Lengthgthth|Mounting dimensions|Qty.y..|Order No.|
|BK 2/E|20 mm|100|7906040000|
|BK 3/E|31 mm|11.0 mm|100|7906060000|
|BK 4/E|38 mm|18.0 mm|100|7906080000|
|BK 6/E|52 mm|32.0 mm|50|7906090000|
|BK 12/E|92 mm|72.5 mm|25|7906100000|
|Typeypee|Qty.y..|Order No.|
|BSTB 28/2 BK U 1-2|50|0203600000|
|HASUE SAKR15LS|n.a.|2038000000|
|BSTB 28/4 BK U 1-4|50|0197300000|
|BSTB 28/6 BK U 1-6|50|0197500000|
|BSTB 28/12 BK U 1-12|50|0198800000|
|BSTO 28/2 BK|50|0203500000|
|BSTO 28/3 BK|50|0203700000|
|BSTO 28/4 BK|50|0197200000|
|BSTO 28/6 BK|50|0197400000|
|BSTO 28/12 BK|50|0198700000|
**----- End of picture text -----**<br>
**==> picture [155 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Typeypee|Lengthgthth|Mounting dimensions|Qty.y..|Order No.|
|MK 3/2/E|17.4 mm|18.5 mm|100|7906110000|
|MK 3/3/E|26.5 mm|18.5 mm|100|7906120000|
|MK 3/4/E|35.75 mm|18.5 mm|50|7906130000|
|MK 3/5/E|45 mm|18.5 mm|50|7906140000|
|MK 3/6/E|54.25 mm|37.0 mm|50|7906150000|
|MK 3/7/E|63.5 mm|37.0 mm|25|7906160000|
|MK 3/8/E|72.75 mm|55.5 mm|25|7906170000|
|MK 3/9/E|82 mm|55.5 mm|25|7906180000|
|MK 3/10/E|91.25 mm|74.0 mm|25|7906190000|
|MK 3/11/E|100.5 mm|74.0 mm|20|7906200000|
|MK 3/12/E|110 mm|92.5 mm|25|7906210000|
**----- End of picture text -----**<br>
## **Accessories**
**==> picture [155 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Typeypee|Qty.y..|Order No.|
|BSTB 28/12 MK U 1-12|50|0245900000|
|BSTB 28/8 MK U 1-8|50|0290200000|
|BSTB 28/6 MK U 1-6|50|0290000000|
|BSTO 28/12 MK|50|0245800000|
|BSTO 28/8 MK3/8|50|0284700000|
|BSTO 28/6 MK|50|0289500000|
|BSTO 28/4 MK3/4|50|0289300000|
**----- End of picture text -----**<br>
(see assortment in catalogue 7) **For detailed information on other accessories and applications, refer to the „Accessories“ section**
**F.6**
**Multi-pole terminal strips for direct mounting**
**MK 6/2...6/E**
**F**
## **6 mm²**
**23 x 22 / 3.4** Refer to order data **0.33...6**
IEC 60947-7-1 **IEC UL CSA** 690 41 6 AWG 22...10 AWG 22...10 8 / 3 A3 / 5VA
#
**Rated connection**
0.5...6 / 1.5...6 0.5...6 / 0.5...4 1.2...2.0 Nm (M 4) 9 / 4.0 x 0.8 mm
**==> picture [155 x 52] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Type|Length|Mounting dimensions|Qty.|Order No.|
|MK 6/2/E|23.5 mm|50|7906220000|
|MK 6/3/E|36.5 mm|13.0 mm|50|7906230000|
|MK 6/4/E|49.5 mm|26.0 mm|20|7906240000|
|MK 6/5/E|62.5 mm|26.0 mm|20|7906250000|
|MK 6/6/E|75.5 mm|52.0 mm|20|7906260000|
**----- End of picture text -----**<br>
**Type Width Qty. Order No.**
**F.7**
**F**
**F.8**
**Contents**
## KLBÜ shielded connection
|**KLBÜ shielded connection**|**Overview shield connection terminals KLBÜ**<br>G.2|
|---|---|
||**Shield connection terminals KLBÜ for 10 x 3 mm busbars**<br>Clamping yoke<br>G.4<br>Busbar holders<br>G.6|
||**Shield connection terminals KLBÜ – Mounting directly on metal plate**<br>Clamping yoke<br>G.8<br>Busbar holder / Spacer<br>G.9|
||**Shield connection terminals KLBÜ – Mounting on TS 35**<br>FM 4-foot / Clamping yoke holder<br>G.10|
||**Shield connection terminals KLBÜ for the C profile**<br>Clamping yoke<br>G.11|
**G**
**G.1**
**Overview shield connection terminals KLBÜ**
## The theoretical concept
Part 1 of the VDE 0133 standard specifies the required equipotential bonding for the electrical components of a machine. The aim is to prevent any undesirable consequences occurring as a result of electrostatic, electromagnetic and net-work bound interference.
The following measures serve this purpose:
- Using filters and time delay devices.
- Dividing earth (PE) into “dirty” and “clean”.
- Neutral grounding using large earth cables for bonding.
- Keeping all bonding leads as short as possible.
- Routing all connections parallel to the bonding surface.
- Separation and shielding of switching devices and interference sensitive equipment, shielded at one end only.
- Shielded lines are used for all motor and all signal connection. These shielded cables for signals are grounded at one end.
- **G** Drives to Motors should be grounded at both ends.
- The mass current is neutral grounded
**==> picture [239 x 258] intentionally omitted <==**
**----- Start of picture text -----**<br>
Control<br>Control signals<br>Digital Analogue CNC – GND CNC – GND Position signals<br>KLBÜ<br>SW +<br>SW -<br>AGND<br>NSTOPPSTOP X5<br>DGND<br>| © ENABLEI/O : : |<br>BTB<br>BTB<br>SHIELD<br>X2 X6<br>Resolver Booster ComputerPersonal-<br>O RS ) RESOLVER PC EO<br>Cog altenttondtonts (©) attention —<br>WPE : | Power supply unit = Mains filter KLBÜ BRAKEXGND+25 V -1 X1 m ® ||*<br>PE<br>i U2V2 ia KLBÜ 3<br>KLBÜ W2<br>WPE Mains filter SSS L1 L L32 a a _i KLBÜ H a)<br>~ © +DC lo, To further<br>–DC servo-amplifiers<br>**----- End of picture text -----**<br>
## Overview of KLBÜ fittings available
For busbars 10 x 3
For direct mounting
For C-profiles
For TS 35 Clip-on for insulating/conducting 10 x 3 busbar
**G.2**
**Overview shield connection terminals KLBÜ**
## In detail
## **Compression spring**
## **No extra tools necessary**
- To ensure both simple handling and • Simply **swivel onto the busbar by** proper connection with permanent **hand** – retrospectively if necessary contact pressure as a result of the spring effect
## **Full range**
- For conductors from 2 to 37 mm
**==> picture [34 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
diameter<br>**----- End of picture text -----**<br>
**G**
## **Reliable contact**
- Changes in diameter (flow) of the conductor compensated for by the elastic behaviour of the clamping yoke for flexible adjustment to the cable diameter
## **Many options available**
- Weidmüller offers a wide range of different fastenings for mounting shield connection terminals
**G.3**
**Shield connection terminals KLBÜ for 10 x 3 mm busbars**
## **Clamping yoke**
Cable fastened against the busbar from below
**G** -
## **KLBÜ**
**==> picture [163 x 209] intentionally omitted <==**
**----- Start of picture text -----**<br>
a b<br>Marking on the product: T<br>Marking EN 50019: T Ex e II<br>Marking EX-RL 94/9/EC: II 2 G D<br>EC type testing certificate: DMT 02 ATEX E 024 U<br>c<br>**----- End of picture text -----**<br>
**==> picture [223 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
KLBÜ 2 x 2-6 KLBÜ 3-8 KLBÜ 4-13.5 KLBÜ 10-20<br>**----- End of picture text -----**<br>
**KLBÜ 15-32**
|**1**||**2**|||**3**|||**4**|
|---|---|---|---|---|---|---|---|---|
|**!**<br>✓<br>~~—~~s||**!**|✓||**T**<br>**b + 4 mm**||||
|✗|||✓||||||
|**Ordering data**|||||||||
|**Type**<br>KLBÜ 2 x 2-6|||**For cable diameter**<br>2.0 ... 6.0 mm||**Dimensions (a x b x c) mm**<br>15.0 x 18.0 x 24.0|||**Qty.**<br>**Order No.**<br>10<br>**1675350000**|
|KLBÜ 3-8|||3.0 ... 8.0 mm||13.0 x 18.0 x 26.0|||10<br>**1600480000**|
|KLBÜ 4 x 13.5|||4.0 ... 13.5 mm||20.0 x 20.5 x 31.5|||10<br>**1592810000**|
|KLBÜ 10-20|||10.0 ... 20.0 mm||25.0 x 26.0 x 40.0|||10<br>**1600490000**|
|KLBÜ 15-32|||15.0 ... 32.0 mm||36.0 x 32.0 x 63.9|||10<br>**1716300000**|
## **Ordering data**
|**10 x 3 mm busbars**|**Length**|**Material**|**Qty.**|**Order No.**|
|---|---|---|---|---|
|SSch 10 x 3 x 1000 Cu,Sn,Pb|1000.0 mm|Cu,Sn,Pb|1|**0348900000**|
|SSch 10 x 3 x 1000 Fe, Zn, 8B|1000.0 mm|Fe, Zn, 8B|1|**1746130000**|
**G.4**
**==> picture [540 x 321] intentionally omitted <==**
**----- Start of picture text -----**<br>
Shield connection terminals KLBÜ for 10 x 3 mm busbars<br>Clamping yoke<br>Cable fastened onto the<br>busbar from above<br>E one a!<br>KLBÜ CO 1 KLBÜ CO 2 KLBÜ CO 3 KLBÜ CO 4 KLBÜ CO 5<br>1 2 " 3<br>KLBÜ shielded connection<br>**----- End of picture text -----**<br>
**! !** ✓ ✓ ~~|~~ -o= ✗ ✓
||||||||||||||||||**!**<br>✗<br>~~|~~|✓<br>~~|~~||**!**<br>✓<br>✓<br> -o=o=||**T**<br>**a + 4 mm**||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**KLBÜ CO**|||||||||||||||||**Ordering data**|||||||||
|||a<br>a||||||b<br>c<br>d<br>A|||||||||**Type**<br>**For cable diameter**<br>**Dimensions (a x b x c x d) mm**<br>**Qty.**<br>**Order No.**<br>KLBÜ CO 1<br>3.0 ... 10.0 mm<br>18.0 x 12.0 x 13.2 x 32.0<br>10<br>**1753311001**<br>KLBÜ CO 2<br>4.0 ... 15.0 mm<br>18.0 x 20.0 x 21.1 x 41.6<br>10<br>**1752131001**<br>KLBÜ CO 3<br>10.0 ... 20.0 mm<br>25.0 x 23.0 x 24.0 x 45.0<br>10<br>**1749151001**<br>KLBÜ CO 4<br>15.0 ... 28.0 mm<br>25.0 x 31.0 x 32.0 x 56.0<br>10<br>**1749161001**<br>KLBÜ CO 5<br>20.0 ... 37.0 mm<br>32.0 x 40.0 x 42.7 x 64.5<br>10<br>**1755081001**<br>~~ee~~|||||||||
||||||||||||||||||**10 x 3 mm busbars**|||**Length**||**Material**||**Qty.**|**Order No.**|
||||||||||||||||||SSch 10 x 3 x 1000 Cu,Sn,Pb|||1000.0 mm||Cu,Sn,Pb||1|**0348900000**|
||||||||||||||||||SSch 10 x 3 x 1000 Fe, Zn, 8B|SSch 10 x 3 x 1000 Fe, Zn, 8B|SSch 10 x 3 x 1000 Fe, Zn, 8B|1000.0 mm||Fe, Zn, 8B||1|**1746130000**|
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|||||||||||||||||||||||||||
|Marking on the product:||||||||Marking on the product:||||||||T||||||||||
|Marking EN 50019:||||||||||||||TEx e II||||||||||||
|Marking EX-RL 94/9/EC:||||||||Marking EX-RL 94/9/EC:||||||II 2 G D||||||||||||
|EC type testing certificate: DMT 02 ATEX E 024 U||||||EC type testing certificate: DMT 02 ATEX E 024 U|||EC type testing certificate: DMT 02 ATEX E 024 U||EC type testing certificate: DMT 02 ATEX E 024 U|||||||||||||||
**G**
**G.5**
**Shield connection terminals KLBÜ for 10 x 3 mm busbars**
## **Busbar holders**
Insulated mounting on TS 35
**==> picture [10 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
G<br>**----- End of picture text -----**<br>
**==> picture [169 x 198] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type WSH 1<br>FULL®<br>aod<br>Horizontal mounting only<br>**----- End of picture text -----**<br>
## **Type WSH 5**
## **Type WSH 3/H/N**
## **Type WSH 6**
## **WSH Ordering data**
EC type testing certificate: DMT 02 ATEX E 024 U
|**Ordering datag data data**|||||
|---|---|---|---|---|
|**Type**<br>WSH 1||**Width**<br>8.0 mm|**Qty.**<br>10|**Order No.**<br>**1068700000**|
|WSH 3/H/N||8.0 mm|10|**1715970000**|
|WSH 5||8.0 mm|10|**1080100000**|
|WSH 6<br>**10 x 3 mm busbars**|**Length**|8.0 mm<br>**Material**|10<br>**Qty.**|**1080200000**<br>**Order No.**|
|SSch 10 x 3 x 1000 Cu, Sn, Pb|1000.0 mm|Cu, Sn, Pb|1|**0348900000**|
**G.6**
**Shield connection terminals KLBÜ for 10 x 3 mm busbars**
## **Busbar holders**
Conductive mounting on TS 35
**==> picture [410 x 16] intentionally omitted <==**
**----- Start of picture text -----**<br>
TS 35-Clip Busbar connector Angled rail<br>BS 35/WSH 2 BFEH 1/WSH SMSE WSH U1MT<br>**----- End of picture text -----**<br>
**==> picture [340 x 37] intentionally omitted <==**
**----- Start of picture text -----**<br>
Installation example 1 Installation example 2<br>• One busbar • Two busbars<br>• 2 x WSH 19 MT • 2 x WSH 18 MT<br>busbar holder set<br>busbar holder set<br>**----- End of picture text -----**<br>
**G**
**==> picture [234 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
WSH Ordering data<br>**----- End of picture text -----**<br>
EC type testing certificate: DMT 02 ATEX E 024 U
|**TS 35-Clip**<br>BS 35/WSH 2<br>**Busbar connector**<br>BFEH 1/WSH<br>**Angled rail**<br>SMSE WSH U1MT<br>**Busbar holder sets**<br>WSH 18 MT|**Dimensions (L x B x H) mm**<br>52.0 x 37.0 x 13.0<br>**Dimensions (L x B x H) mm**<br>20.0 x 31.0 x 13.5<br>**Dimensions (L x B x H) mm**<br>134.0 x 13.0 x 134.0<br>Contents (parts loose in plastic bag)<br>BS 35/WSH 2<br>BFEH 1/WSH<br>1 ea.<br>2 ea.|Contents (parts loose in plastic bag)<br>SMSE WSH U1MT<br>2 ea.|**Qty.**<br>10<br>**Qty.**<br>10<br>**Qty.**<br>10<br>**Qty.**<br>10|**Order No.**<br>**1760720000**<br>**Order No.**<br>**1082400000**<br>**Order No.**<br>**1083900000**<br>**Order No.**<br>**1083100000**|
|---|---|---|---|---|
|WSH 19 MT|1 ea.<br>1 ea.|1 ea.|10|**1083200000**|
|WSH 20 MT<br>**10 x 3 mm busbars**|1 ea.<br>1 ea.<br>**Length**|1 ea. (straight)<br>**Material**|10<br>**Qty.**|**1752950000**<br>**Order No.**|
|SSch 10 x 3 x 1000 Cu,Sn,Pb|1000.0 mm|Cu,Sn,Pb|1|**0348900000**|
|SSch 10 x 3 x 1000 Fe, Zn, 8B|1000.0 mm|Fe, Zn, 8B|1|**1746130000**|
**G.7**
**Shield connection terminals KLBÜ – Mounting directly on metal plate**
## **Clamping yoke**
**==> picture [10 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
G<br>**----- End of picture text -----**<br>
**==> picture [86 x 90] intentionally omitted <==**
**----- Start of picture text -----**<br>
Drilling template KLBÜ 15-32 SC<br>ø 4.2 mm<br>M4<br>+.<br>oOo<br>10 mm<br>**----- End of picture text -----**<br>
## **KLBÜ SC**
**==> picture [98 x 97] intentionally omitted <==**
**----- Start of picture text -----**<br>
a<br>c<br>b<br>Ss<br>——<br>| LS<br>|sco<br>d<br>e<br>**----- End of picture text -----**<br>
**KLBÜ 3-8 SC**
**KLBÜ 4-13.5 SC**
**KLBÜ 10-20 SC**
**KLBÜ 15-32 SC**
**2**
**==> picture [6 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
3<br>**----- End of picture text -----**<br>
**==> picture [6 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>**----- End of picture text -----**<br>
**==> picture [328 x 205] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|!|a > b = a < b =|✓✗|!|✗|✓|!|✓|T|c + 4 mm|
|A|F|o)|Fo)|ee|
|✓|
|Ordering datag data data|
|Type|For cable diameter|Thread length|Dimensions (a x b x c) mm|Qty.|Order No.|
|KLBÜ 3-8 SC|3.0 ... 8.0 mm|5.65 mm|13.5 x 11.5 x 18.0 x 26.0|10|1692261001|
|KLBÜ 4-13.5 SC|4.0 ... 13.5 mm|5.30 mm|20.0 x 17.8 x 20.3 x 31.4|10|1712311001|
|KLBÜ 10-20 SC|10.0 ... 20.0 mm|5.30 mm|24.8 x 23.0 x 26.0 x 40.0|10|1712321001|
|KLBÜ 15-32 SC|15.0 ... 32.0 mm|4.80 mm|36.0 x 33.3 x 32.0 x 64.0|10|1718341001|
|Operating tool|Qty.|Order No.|
|BTWZ KLBÜ|1|1742630000|
**----- End of picture text -----**<br>
## **Ordering datag data data**
**==> picture [163 x 47] intentionally omitted <==**
**----- Start of picture text -----**<br>
Marking on the product: T<br>Marking EN 50019: T Ex e II<br>Marking EX-RL 94/9/EC: II 2 G D<br>EC type testing certificate: DMT 02 ATEX E 024 U<br>**----- End of picture text -----**<br>
**G.8**
**Shield connection terminals KLBÜ – Mounting directly on metal plate**
## **Busbar holder / Spacer**
**==> picture [500 x 198] intentionally omitted <==**
**----- Start of picture text -----**<br>
Busbar holder 28<br>Set (WSH 4 MT) consisting of:<br>– 1 busbar holder 10 x 3<br>– 1 busbar connector (BFEH 1/WSH)<br>12<br>Mounting plate<br>40.5<br>ø Du for M 5<br>ø = 5.2 mm<br>Spacer<br>M6 outer and inner thread<br>(15 mm, 20 mm and 30 mm long)<br>70<br>**----- End of picture text -----**<br>
**G**
## **WSH 4 MT / SP**
## **Ordering data**
EC type testing certificate: DMT 02 ATEX E 024 U **Busbar holder Qty. Order No.** WSH 4 MT 10 **1079900000**
|**Type**|**Length**|**Qty.**|**Order No.**|
|---|---|---|---|
|SP 15,set of 2|15 mm|1|**3896100000**|
|SP 20,set of 2|20 mm|1|**3896200000**|
|SP 30, set of 2|30 mm|1|**3896300000**|
**G.9**
**Shield connection terminals KLBÜ – Mounting on TS 35**
## **FM 4 foot / Clamping yoke holder**
**==> picture [35 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
FM 4 foot<br>**----- End of picture text -----**<br>
**==> picture [106 x 28] intentionally omitted <==**
**----- Start of picture text -----**<br>
The KLBÜ SC clamping yokes<br>(see page G.8)<br>are screwed onto the FM 4 foot.<br>**----- End of picture text -----**<br>
**==> picture [81 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Clamping yoke holder<br>**----- End of picture text -----**<br>
**G**
**==> picture [63 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
FM 4 / BS 35 II<br>**----- End of picture text -----**<br>
**==> picture [274 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
BS 35 II BS 35 II / KLBÜ 3-8 BS 35 II / KLBÜ 3-8 / 2 x 2-6<br>(without KLBÜ)<br>**----- End of picture text -----**<br>
|**Ordering data**||||
|---|---|---|---|
|**FM 4 foot**<br>FM 4<br>**Clamping yoke holder**|**For cable diameter**|**Qty.**<br>40<br>**Qty.**|**Order No.**<br>**0687900000**<br>**Order No.**|
|BS 35 II|without KLBÜ|10|**1723800000**|
|BS 35 II / KLBÜ 3-8|3.0 ... 8.0 mm|10|**1723810000**|
|BS 35 II / KLBÜ 4-13.5|4.0 ... 13.5 mm|10|**1723820000**|
|BS 35 II / KLBÜ 3-8/2 x 2-6|3.0 ... 8.0 mm / 2.0 ... 6.0 mm|10|**1749430000**|
|BS 35 II / KLBÜ 2 x 3-8/2 x 2-6|3.0 ... 8.0 mm / 2.0 ...6.0 mm|10|**1768020000**|
Marking on the product: T Marking EN 50019: T Ex e II Marking EX-RL 94/9/EC: II 2 G D EC type testing certificate: DMT 02 ATEX E 024 U
**G.10**
**KLBÜ shielded connection terminals for the C profile**
## **Clamping yoke**
**KLBÜ 3-8 CPF**
**KLBÜ 4-13.5 CPF**
**KLBÜ 10-20 CPF**
**KLBÜ 15-32 CPF**
**G**
|**KLBÜ CPF**|**KLBÜ CPF**|**KLBÜ CPF**|**KLBÜ CPF**|**KLBÜ CPF**|**KLBÜ CPF**|||||||||||||||||**Ordering data**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||b<br>a|||||||||c||||||||**Type**<br>**For cable diameter**<br>**Dimensions (a x b x c x d) mm**<br>**Qty.**<br>**Order No.**<br>KLBÜ 3-8 CPF<br>3.0 ... 8.0 mm<br>13.5 x 11.5 x 18.0 x 26.0<br>10<br>**1752681001**<br>KLBÜ 4-13.5 CPF<br>4.0 ... 13.5 mm<br>20.0 x 17.8 x 20.3 x 31.4<br>10<br>**1752691001**|
|||||||||||||||||||||||KLBÜ 10-20 CPF<br>10.0 ... 20.0 mm<br>24.8 x 23.0 x 26.0 x 40.0<br>10<br>**1752701001**|
||S|<br>_**—**—<br>=>|||||||||||se<br><=T<br>><br><=T||||||||d||KLBÜ 15-32 CPF<br>15.0 ... 32.0 mm<br>36.0 x 33.3 x 32.0 x 64.0<br>10<br>**1752711001**|
||||||||||||||||||||||||
|||||||||||||||||||||e|||
||||||||||||||||||||||||
||||||||||||||||||||||||
||||||||||||||||||||||||
||||||||||||||||||||||||
||||||||||||||||||||||||
||||||||||||||||||||||||
|||||||||||||||||||||||**C-rail**<br>**Qty.**<br>**Order No.**|
|||||||||||||||||||||||TS 27 x 12.5M / ST / F.ZN<br>10 m<br>**1802690000**|
**==> picture [163 x 47] intentionally omitted <==**
**----- Start of picture text -----**<br>
Marking on the product: T<br>Marking EN 50019: T Ex e II<br>Marking EX-RL 94/9/EC: II 2 G D<br>EC type testing certificate: DMT 02 ATEX E 024 U<br>**----- End of picture text -----**<br>
**G.11**
**G**
**G.12**
**Contents**
## Busbars / Terminal rails
## **Busbars / Terminal rails**
||**Busbar systems**||
|---|---|---|
||Busbar overview|H.2|
||Busbars|H.3|
||Cable clamp, uninsulated|H.6|
||Cable clamp, insulated|H.7|
||**Terminal rail systems**||
||Overview Terminal rails|H.8|
||Terminal rails TS 15, TS 32, TS 35|H.10|
||End brackets|H.13|
||Terminal rail supports / Mounting feet|H.14|
**H**
**H.1**
**Busbar overview**
**H**
## Busbars
In switchgears and controls, it may be necessary to bring the neutral conductor and the protective conductor together at a central point. Busbars are available for this purpose and can be used for connecting a large number of conductors in a confined space (up to 70 conductors on a 1 m busbar). The conductors are connected by means of a screw clamp or tension clamp. usbars are held in position by pressure clamps or screw clamps onto the busbar holders. The cable clamps can be pushed on the busbar and adjusted to the entire wiring in the system. The busbars can be used unperforated in any lengths. They are fixed using the SH busbar holder which can, for longer busbars, also be positioned between the clamps.
in the system. The cable clamp serves as the protective conductor connection and can be supplied with green/yellow insulating caps. These caps indicate the protective function and marking tags allow clear identification of each conductor. If the cable clamps are used to connect neutral conductors, they can be marked with a blue insulating cap.
ZBE 6 can also be swivelled onto the busbar retrospectively
In order to bring together neutral conductors and protective conductors at a central point, it is advantageous to use ZB cable clamps together with 10 x 3 or 6 x 6 busbars. The cable clamps can be pushed onto the busbar and adjusted to the entire wiring
## **Cable clamps**
**H.2**
**Busbars**
**H**
## **Busbars, unperforated**
## **Busbars, perforated**
## **SSch**
**==> picture [331 x 266] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Type|Material|Cross-section|Length|Current carrying capacity|Qty.|Order No.|
|SSch 10 x 3|Copper, tin-plated|10 x 3 mm|1 m|140 A|1|0348900000|
|SSch 10 x 3|Steel,|galvanised|10 x 3 mm|1 m|1|0438000000|
|SSch 10 x 3|Brass, blank|10 x 3 mm|1 m|100 A|1|0259800000|
|SSch 6 x 6|Copper, tin-plated|6 x 6 mm|1 m|140 A|1|0571300000|
|SSch 6 x 6|Brass, blank|6 x 6 mm|1 m|100 A|1|0571200000|
|SSch 15 x 6|Copper, tin-plated|15 x 6 mm|1 m|265 A|1|0357400000|
|NSch / ESch|
|Type|Material|Cross-section|Length|Current carrying capacity|Qty.|Order No.|
|NSch 15 x 2|Copper, blank|15 x 2 mm|1 m|80 A|1|0280200000|
|ESch 12 x 2|Steel,|galvanised|12 x 2 mm|1 m|1|0280300000|
|Pressure piece|Qty.|Order No.|
|DKSUE|100|0280100000|
|Clamping screw|Qty.|Order No.|
|BFSC M5 x 8|100|0296700000|
**----- End of picture text -----**<br>
## **Connection data NSch / ESch**
**==> picture [159 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Screw connection solid|0.5 ... 2.5 mm|[2]|
|Stripping length|9 mm|
|Cable lug connection|max. 16 mm|[2]|
|Max. current per connection|27 A|
**----- End of picture text -----**<br>
**H.3**
**==> picture [37 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Busbars<br>**----- End of picture text -----**<br>
##
**==> picture [542 x 668] intentionally omitted <==**
**----- Start of picture text -----**<br>
Busbar holders SH<br>With clip and base Type Figure For busbar cross-section Qty. Order No.<br>SH 1 TS 15 complete 1. 10 x 3, 6 x 6, 15 x 2, 12 x 2 20 0299860000<br>2. 15 x 2, 15 x 6<br>Se<br>26.5<br>24.5<br>1. 12.510.56.5 2. 24.515<br>2<br>1<br>Individual parts SH1<br>SH 1 Base 20 0401460000<br>hed 0 eee<br>SH 1 Clip 500 0635960000<br>*<br>Fixing screw for SH1<br>BFSC M4x9 for 1 SH1 100 0103300000<br>a =8=8=—h—<br>BFSC M4x30 for 2 SH1 stacked 50 0267100000<br>With metal bridge Type For busbar cross-section Qty. Order No.<br>% fo 26 SH 2S 10 x 3, 6 x 6, 15 x 6, 10 x 5 10 0641720000<br>40<br>H<br>.<br>5.7<br>Type Qty. Order No.<br>SH 2 The arrangement of mounting rails in totally 10 0494920000<br>insulated facilities<br>40<br>So<br>5.7<br>With metal bridge Type For busbar cross-section Qty. Order No.<br>15 SH 3 10 x 3, 6 x 6, 10 x 5 10 0556660000<br>65<br>4.5<br>20.6 24<br>35.5 32<br>22.2 21<br>40<br>2<br>15 6.5<br>22.2 21<br>40<br>2<br>15 6.5<br>32.5<br>4.5<br>65 55 4.5<br>45<br>10<br>**----- End of picture text -----**<br>
**H.4**
**Busbars**
## **Busbar holders**
## **WEW**
**==> picture [512 x 396] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type For busbar cross-section Qty. Order No.<br>WEW 35/1 10 x 3, 6 x 6 50 1059000000<br>ee ea ; | WEW 35/2 10 x 3, 6 x 6 100 1061200000<br>WEW 35/1 and WEW35/2 as<br>busbar holder together with<br>the ZB 4 G tension clamp<br>Connection element AK 95<br>Type For busbar cross-section Qty. Order No.<br>AK 95 15 x 6 mm 10 0364200000<br>The AK 95 connection element is used as a tension clamp for 15 x 6 busbars Connection<br>cross-sections: e = 6…16 mm [2]<br>f = 6…50 mm [2]<br>m = 16…50 mm [2]<br>Sa 36<br>SS ae<br>M6<br>36 10<br>**----- End of picture text -----**<br>
**H**
**H.5**
**Busbars**
## **Cable clamp, uninsulated**
**H**
## **For 10 x 3 mm busbars**
Connection cross-section: Solid 0.5 ... 6.0 mm[2] Flexible 0.5 ... 4.0 mm[2] Stranded - Clamping screw M 3 Stripping length 16 mm **For retrofitting** Connection cross-section: Solid 1.0 ... 10 mm[2] Flexible 1.5 ... 10 mm[2] Stranded - Clamping screw M 4 rr Stripping length 19 mm **Also for 10 x 5 mm busbar** Connection cross-section: Solid 1.5 ... 10 mm[2] Flexible 2.5 ... 10 mm[2] Stranded - Clamping screw M 4 Stripping length 19 mm Connection cross-section: Solid 2.5 ... 16 mm[2] Flexible 2.5 ... 16 mm[2] Stranded 16 ... 25 mm[2] Clamping screw M 4 Stripping length 16 mm Connection cross-section: Solid - Flexible 16 ... 35 mm[2] Stranded 16 ... 50 mm[2] Clamping screw M 6 Stripping length 19 mm
## **For 6 x 6 mm busbar**
Connection cross-section: Solid 0.5 ... 6,0 mm[2] Flexible 0.5 ... 4,0 mm[2] Stranded - Clamping screw M 3 Stripping length 16 mm Connection cross-section: Solid 2.5 ... 16 mm[2] Flexible 2.5 ... 16 mm[2] Stranded 16 ... 25 mm[2] Clamping screw M 4 Stripping length 12 mm
## **ZB / ZBE**
||**Type**<br>**Colour**<br>**Dimensions [mm]**<br>**Qty.**<br>**Order No.**<br>**a**<br>**width**<br>**c**<br>**h1**<br>ZB 4,blank<br>-<br>11.7<br>5.6<br>16.0<br>10.0<br>50<br>**0316500000**|
|---|---|
||Insulatingcap<br>blue<br>50<br>**0475480000**|
||Insulatingcap<br>green /yellow<br>50<br>**0475460000**|
|ZBE 6,blank<br>-<br>19.5<br>8.2<br>19.5<br>19.0<br>50<br>**0459500000**<br>Insulatingcap<br>blue<br>50<br>**0526080000**<br>Insulatingcap<br>green /yellow<br>50<br>**0526060000**<br>ZB 10,blank<br>-<br>19.5<br>8.2<br>19.5<br>19.0<br>50<br>**1261300000**<br>—————_——<==@&2£6w0U~“=7OI||
||ZB 16,blank<br>-<br>17.0<br>10.0<br>16.0<br>17.0<br>50<br>**0316600000**|
||Insulatingcap<br>blue<br>50<br>**0502980000**|
||Insulatingcap<br>green /yellow<br>50<br>**0502960000**|
||ZB 35,blank<br>-<br>21.0<br>14.4<br>18.4<br>20.5<br>20<br>**0266500000**|
||Insulatingcap<br>blue<br>50<br>**0502780000**|
|||
||**ZB**|
||**Type**<br>**Colour**<br>**Dimensions [mm]**<br>**Qty.**<br>**Order No.**<br>**a**<br>**b**<br>**c**<br>**h1**<br>ZB 4/6,blank<br>14.7<br>5.6<br>12.5<br>10.0<br>50<br>**0556700000**|
||ZB 16/6,blank<br>19.0<br>10.0<br>12.5<br>17.0<br>50<br>**0556800000**|
**H.6**
**Busbars**
**H**
## **Cable clamp, insulated**
## **For 10 x 3 mm busbars**
**==> picture [159 x 331] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Connection cross-section:|
|Solid|0.5 ... 6.0 mm|[2]|
|Flexible|0.5 ... 4.0 mm|[2]|
|Stranded|-|
|Clamping screw|M 3|
|Stripping length|16 mm|
|For retrofitting|
|Connection cross-section:|
|Solid|1.0 ... 10 mm|[2]|
|Flexible|1.5 ... 10 mm|[2]|
|Stranded|-|
|Clamping screw|M 4|
|Stripping length|19 mm|
|Connection cross-section:|
|Solid|2.5 ... 16 mm|[2]|
|Flexible|2.5 ... 16 mm|[2]|
|Stranded|16 ... 25 mm|[2]|
|Clamping screw|M 4|
|Stripping length|16 mm|
|Connection cross-section:|
|Solid|-|
|Flexible|16 ... 35 mm|[2]|
|Stranded|16 ... 50 mm|[2]|
|Clamping screw|M 6|
|Stripping length|19 mm|
|Tension clamp connection|
|Connection cross-section:|
|Solid|0.5 ... 4.0 mm|[2]|
|Flexible|0.5 ... 2.5 mm|[2]|
|Stranded|-|
|Stripping length|10 mm|
**----- End of picture text -----**<br>
## **For 6 x 6 mm busbar**
**==> picture [86 x 133] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Connection cross-section:|
|Solid|0.5 ... 6.0 mm|[2]|
|Flexible|0.5 ... 4.0 mm|[2]|
|Stranded|-|
|Clamping screw|M 3|
|Stripping length|16 mm|
|Connection cross-section:|
|Solid|2.5 ... 16 mm|[2]|
|Flexible|2.5 ... 16 mm|[2]|
|Stranded|16 ... 25 mm|[2]|
|Clamping screw|M 4|
|Stripping length|12 mm|
**----- End of picture text -----**<br>
## **ZB / ZBE /ZF**
**==> picture [328 x 322] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Type|Colour|Dimensions [mm]|Qty.|Order No.|
|a2|width|d|h2|
|ZB 4 G GN/GE|green/yellow|27.0|7.6|19.7|15.5|50|0322160000|
|ZB 4 G BL|blue|27.0|7.6|19.7|15.5|50|0322180000|
|ZB 4 G SW|black|27.0|7.6|19.7|15.5|50|0322110000|
|ZB 4K GN/GE|grün/gelb|18.5|6.0|19.0|13.0|50|0475360000|
|ZB 4K BL|blue|18.5|6.0|19.0|13.0|50|0475380000|
|ZBE 6K GN/GE|green/yellow|27.0|8.0|22.5|23.0|50|0525960000|
|ZBE 6K BL|blue|27.0|8.0|22.5|23.0|50|0525980000|
|ZBE 6K SW|black|27.0|8.0|22.5|23.0|50|0525910000|
|ZB 16K GN/GE|green/yellow|24.0|10.0|19.2|20.0|50|0502860000|
|ZB 16K BL|blue|24.0|10.0|19.2|20.0|50|0502880000|
|ZB 35K GN/GE|green/yellow|25.0|14.4|32.0|20.5|20|0502660000|
|ZB 35K BL|blue|25.0|14.4|32.0|20.5|20|0502680000|
|ZB 35K SW|black|25.0|14.4|32.0|20.5|20|0502610000|
|ZF 4 S|beige|22.0|6.1|24.5|-|50|1814680000|
|ZF 4 S BL|blue|22.0|6.1|24.5|-|50|1814660000|
|ZF 4 S GN/GE|green/yellow|22.0|6.1|24.5|-|50|1814670000|
**----- End of picture text -----**<br>
**==> picture [331 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|ZB|
|Type|Colour|Dimensions [mm]|Qty.|Order No.|
|a2|b|d|h2|
|ZB 4/6K GN/GE|green/yellow|21.2|6.0|25.0|14.0|50|0565460000|
|ZB 4/6K BL|blue|21.2|6.0|25.0|14.0|50|0565480000|
|ZB 16/6K GN/GE|green/yellow|26.0|9.7|25.0|20.0|50|0569660000|
**----- End of picture text -----**<br>
**H.7**
**Overview Terminal rails**
## Terminal rail systems
Both active and passive components and intelligent modules are mounted on terminal rails – a method which has proven its orth over the years. But it is only after the use of certain consumables – which are frequently not taken into consideration – that electrical installation is finally completed. In this chapter, users will find a range of terminal rails and profile rails for component installation together with end brackets for holding and isolating the components. This guarantees firm installation and isolation. Weidmüller supplies components which show perfect functional compatibility.
Terminal rails are made of either steel, stainless steel, aluminium, copper or plastic, depending on the area of application.
## **Stainless steel**
Stainless steel is a collective noun for all kinds of steel (alloys) which are smelted in a special process and have a high degree **H** of purity. Stainless steel has much-enhanced resistance to corrosion. Weidmüller’s stainless steel terminal rails have the following composition: X5 CrNi 18-10 stainless steel (i.e. ~ 18 % chromium, ~ 10 % nickel).
## **Steel**
Weidmüller started developing RoHS-compliant surfaces at a very early stage to meet the requirements of EU directives. This commitment is now paying off because Weidmüller products comply with the statutory instruments at an early date and provide you, the customer, with the customary, high Weidmüller quality. All the yellow-passivated surfaces so well known to users will in future be replaced by terminal rails with the new **WIN-Q** surface finish. This name stands for the Weidmüller quality, in other words excellent surface protection and, at the same time, excellent electrical properties.
A terminal rail can also be used as a protective conductor busbar. Weidmüller PE / earth terminals in the W-Series, Z-Series, I-Series, SAK- and AKZ-Series comply with requirements stipulated in IEC 60 947-7-2. According to VDE 0100 part 540, for conductors with cross-sectional areas exceeding 10 mm[2] , both protective and neutral conductors may be grouped together as a single category of conductors designated PEN.
If a terminal rail is used as a PEN busbar, the following criteria must be observed:
## **Aluminium**
- Only E-Cu or aluminium profiles are allowed
Aluminium is second only to copper in its electrical conductivity. One advantage is its light weight. Aluminium oxidises quickly in air; thus passivated, it offers excellent corrosion protection.
- Short-circuit currents and thermal rated currents must be taken into account
- The terminal rails are to be insulated as a contribution to protective insulation
## **Copper**
Copper, a heavy metal, has the best electrical conductivity of all metals used. As it is a soft metal, Weidmüller’s terminal rails are 2.3 mm thick.
## **Plastic**
The plastic terminal rail scores on two counts: firstly, its insulating properties, and secondly, its low weight. This leads to its use in special applications where, for example, clearance and creepage distances with respect to the mounting plate cannot be achieved with the standard terminal rails.
**H.8**
**Overview Terminal rails**
All unperforated terminal rails can be provided with fixing holes (state dimensions h and l2). Possible diameters are 3.5 / 5.6 / 5.5 / 7 mm.
**==> picture [41 x 42] intentionally omitted <==**
**----- Start of picture text -----**<br>
TS 15<br>U<br>15 mm<br>5,5 mm<br>**----- End of picture text -----**<br>
All unperforated steel rails can also be supplied with welded on steel studs (state dimension a and required studs).
**==> picture [66 x 97] intentionally omitted <==**
**----- Start of picture text -----**<br>
I1<br>I1 I2<br>I2<br>35 h<br>35 h<br>**----- End of picture text -----**<br>
**==> picture [45 x 51] intentionally omitted <==**
**----- Start of picture text -----**<br>
TS 32<br>Y<br>- 32 mm 5,5 mm<br>**----- End of picture text -----**<br>
**==> picture [10 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
H<br>**----- End of picture text -----**<br>
**==> picture [459 x 164] intentionally omitted <==**
**----- Start of picture text -----**<br>
a<br>TS 35<br>M 5x8<br>_<br>Stud M 6x12 TS 35 x 7.5<br>a<br>TS 32<br>W<br>M 5x8 35 mm<br>Stud M 6x12<br>TS 15 a TS 35 x 15<br>M 5x6<br>—+ Stud<br>V<br>¥ —_ 35 mm<br>Soap 4 fA<br>7,5 mm<br>15 mm<br>**----- End of picture text -----**<br>
**H.9**
**Terminal rails**
**==> picture [214 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
TS 15 terminal rail U<br>15 mm<br>TS 15 x 5<br>5,5 mm<br>**----- End of picture text -----**<br>
**==> picture [39 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Unperforated<br>**----- End of picture text -----**<br>
## **With slotted hole**
**==> picture [337 x 205] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|Aluminium|Short-circuit strength|Material thickness|Length|Qty.|Order No.|
|TS 15x5 2M/AL/BK|16 mm|[2]|1 mm|2 m|10 m|0134700000|
|(max. permissible rated current for PEN function = 76 A)|
|Steel, galvanised and passivated|
|TS 15x5 2M/ST/ZN|10 mm|[2]|1 mm|2 m|2 m|0514200000|
|Aluminium|Short-circuit strength|Material thickness|Length|Qty.|Order No.|
|TS 15x5/LL 2M/AL/BK|16 mm|[2]|1 mm|2 m|2 m|0217900000|
|(max. permissible rated current for PEN function = 76 A)|
|Steel, galvanised and passivated|
|TS 15x5/LL 2M/ST/ZN|10 mm|[2]|1 mm|2 m|2 m|0117500000|
|iis|TS 15x5/LL 1M/ST/ZN|10 mm|[2]|A|TATA|1 mm|TN|1 m|10 m|0117510000|
**----- End of picture text -----**<br>
**H**
**==> picture [511 x 187] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|TS 32 terminal rail|Y|
|32 mm|
|TS 32 x 15|
|Unperforated|Aluminium|Short-circuit strength|Material thickness|Length|Qty.|Order No.|
|TS 32X15 2M/AL/BK|70 mm|[2]|1.5 mm|2 m|2 m|0169300000|
|(max. permissible rated current for PEN function = 192 A)|
|Steel, galvanised and passivated|
|TS 32X15 2M/ST/ZN|35 mm|[2]|1.5 mm|2 m|2 m|0122800000|
|Copper|
|TS 32X16.2 2M/CU/BK|120 mm|[2]|2.1 mm|2 m|2 m|0364300000|
|(max. permissible rated current for PEN function = 269 A)|
|f|y|ss|
|Stainless steel|
|TS 32X15 2M/CRN|35 mm|[2]|1.5 mm|2 m|2 m|0293220000|
|With slotted hole|Steel, galvanised and passivated|Short-circuit strength|Material thickness|Length|Qty.|Order No.|
|TS 32X15/LL 2M/ST/ZN|35 mm|[2]|1.5 mm|2 m|2 m|0514400000|
**----- End of picture text -----**<br>
**H.10**
**Terminal rails**
**==> picture [161 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
TS 35 x 7,5 terminal rail W<br>35 mm<br>7,5 mm<br>**----- End of picture text -----**<br>
## **TS 35 x 7.5**
**==> picture [386 x 152] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Aluminium|Short-circuit strength|Material thickness|Length|Qty.|Order No.|
|TS 35X7.5 2M/AL/BK|35 mm|[2]|1 mm|2 m|2 m|0330800000|
|(max. permissible rated current for PEN function = 125 A)|
|Steel, galvanised and passivated|
|TS 35X7.5 2M/ST/ZN|16 mm|[2]|1 mm|2 m|2 m|0383400000|
|TS 35X7.5 1M/ST/ZN|16 mm|[2]|1 mm|1 m|10 m|0383410000|
|Stainless steel|
|TS 35X7.5 2M/CRN|16 mm|[2]|1 mm|2 m|2 m|1747350000|
|Steel, galvanised and passivated|Short-circuit strength|Material thickness|Length|Qty.|Order No.|
|TS 35X7.5/LL 2M/ST/ZN|16 mm|[2]|1 mm|2 m|2 m|0514500000|
|TS 35X7.5/LL 1M/ST/ZN|16 mm|[2]|1 mm|1 m|10 m|0514510000|
|titlI;|Ts|8|—|||
**----- End of picture text -----**<br>
**==> picture [49 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
Unperforated<br>With slotted hole<br>**----- End of picture text -----**<br>
**==> picture [525 x 434] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|TS 35X7.5/LL/6 2M/ST/ZN|16 mm|[2]|1 mm|2 m|2 m|0514570000|
|hii|Ts|8|—|||
|oh|
|in||6.2|
|TS 35 x 15 terminal rail|V|
|35 mm|TS 35 x 15|
|Unperforated|Copper|Short-circuit strength|Material thickness|Length|Qty.|Order No.|
|TS 35X15/2.3 2M/CU/BK|150 mm|[2]|2.3 mm|2 m|2 m|0270100000|
|(max. permissible rated current for PEN function = 309 A)|
|Steel, galvanised and passivated|
|TS 35X15/2.3 2M/ST/ZN|50 mm|[2]|2.3 mm|2 m|2 m|0498000000|
|Aluminium|
|TS 35X15/2.3 2M/AL/BK|70 mm|[2]|2.3 mm|2 m|2 m|1848290000|
|—|(max. permissible rated current for PEN function = 192 A)|
|Unperforated|Steel, galvanised and passivated|Short-circuit strength|Material thickness|Length|Qty.|Order No.|
|TS 35X15 2M/ST/ZN|25 mm|[2]|1.5 mm|2 m|2 m|0236400000|
|With slotted hole|Steel, galvanised and passivated|Short-circuit strength|Material thickness|Length|Qty.|Order No.|
|TS 35X15/LL 2M/ST/ZN|25 mm|[2]|1.5 mm|2 m|2 m|0236500000|
|TS 35X15/LL 1M/ST/ZN|25 mm|[2]|1.5 mm|1 m|10 m|0236510000|
|TS 35X15LL/5 2M/ST/ZN|25 mm|[2]|1.5 mm|2 m|2 m|1837380000|
|i|5.2|
|TS 35X15/LL/6x18 2M/ST/ZN|25 mm|[2]|1.5 mm|2 m|2 m|1805980000|
|-|
|va|
|6.3|
|TS 35X15/LL/6x25 2M/ST/ZN|25 mm|[2]|1.5 mm|2 m|2 m|1866290000|
**----- End of picture text -----**<br>
**==> picture [159 x 21] intentionally omitted <==**
**----- Start of picture text -----**<br>
TS 35 x 15 terminal rail V<br>35 mm<br>15 mm<br>**----- End of picture text -----**<br>
**H**
**==> picture [20 x 35] intentionally omitted <==**
**----- Start of picture text -----**<br>
rr<br>il<br>6.3<br>11<br>25<br>**----- End of picture text -----**<br>
**H.11**
**Terminal rails**
**H**
|**TS 35 x 15 terminal rail**<br>**Unperforated**|V<br>35 mm|15 mm||**TSK 35 x 15**<br>**Plastic PVC RAL 7035**<br>**Length**<br>**Qty.**<br>**Order No.**<br>TSK 35X15 2M PVC/GR<br>2 m<br>2 m<br>**0514300000**|
|---|---|---|---|---|
**H.12**
**Terminal rails**
**H**
## **End brackets**
## **For TS 15 terminal rail**
**==> picture [241 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Polyamide 66, screw-in|Colour|Torque|Qty.|Order No.|
|EWK AKA 2.5|beige|0.4 Nm|50|0348660000|
|EW 15|beige|0.4 Nm|50|0382860000|
|Polyamide with fibreglass, screw-in|
|EW 15/2|dark beige|0.4 Nm|50|1071900000|
|Polyamide 66, screwless|
|ZEW 15|beige|20|7920340000|
**----- End of picture text -----**<br>
**==> picture [206 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
EW 15<br>EW 15/2<br>ZEW 15<br>**----- End of picture text -----**<br>
## **For terminal rail TS 32**
**==> picture [241 x 60] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Polyamide 66, screw-in|Colour|Torque|Qty.|Order No.|
|EWK 2|beige|1.2 Nm|50|0199360000|
|EWK 1 TS 32 M4X18|beige|1.2 Nm|50|0206160000|
|EWK 1 ALT|beige|0.6 Nm|50|0495160000|
|Polyamide with fibreglass, screw-in|
|WEW 32/1|dark beige|0.5 Nm|50|1067600000|
**----- End of picture text -----**<br>
**==> picture [217 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
EWK 1<br>EWK 1 ALT<br>=) EWK 2<br>**----- End of picture text -----**<br>
## **For terminal rail TS 35**
**==> picture [241 x 97] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Polyamide 66, screw-in|Colour|Torque|Qty.|Order No.|
|EW 35|beige|0.5 Nm|50|0383560000|
|EW 35 GR|grey|0.5 Nm|50|0383530000|
|Polyamide with fibreglass, screw-in|
|WEW 35/1|dark beige|1.2 Nm|50|1071900000|
|WEW-35/2|dark beige|0.5 Nm|100|1061200000|
|Polyamide 66, screwless|
|ZEW (6 mm)|beige|20|9540000000|
|ZEW 35/2 (8 mm)|beige|20|8630740000|
**----- End of picture text -----**<br>
**==> picture [218 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
EW 35<br>WEW 35/1<br>WEW 35/2 ZEW 35/2<br>**----- End of picture text -----**<br>
**H.13**
**Terminal rails**
## **Terminal rail supports / Mounting feet**
## **Terminal rail supports**
**H**
**TSTW 6/M6 TSTW D 4.3**
**==> picture [15 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
TST<br>**----- End of picture text -----**<br>
**==> picture [251 x 363] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|Thread|Qty.|Order No.|
|TSTW 5/M5|M5|10|0178100000|
|es|TSTW 5/M5 galvanised|M6|10|1779100000|==—|
|TSTW 6/M6|M5|10|0164000000|
|_Ci‘(‘$UCOCtstststsi(‘(‘(‘(‘ia<“|TSTW D 4.3|Hole ø 4.3 mm|10|1610110000|me|
|Terminal rail supports of type|TSTW|are used for|
|angled fixing of terminal rails at an angle of 35°.|
|TST 2/M5|M5|10|1286600000|
|TST 2/M6|M6|10|0101700000|
|The|TST|terminal rail support is used for assembly|
|of terminal rails in a frame or over a cut-out|
|Fixing screws|
|FKSC M5x8 Ø9|50|0295900000|
|FKSC M6x8 Ø9|50|0642600000|
|FKSC M6x12 Ø9|50|0353500000|
|Weidmüller supplies fixing screws with hexagonal sockets and a very low|
|head for the terminal rail supports so that the terminals can also be fitted|
|over the screw.|
**----- End of picture text -----**<br>
**H.14**
**Terminal rails**
**H**
## **Terminal rail supports / Mounting feet**
## **Mounting feet**
|**FM**|**Clip-on foot, steel for TS 35 Thread**<br>**Qty.**<br>**Order No.**<br>FM 4<br>M4<br>40<br>**0687900000**<br>FM 5<br>M5<br>40<br>**0636800000**<br>FM 6<br>M6<br>40<br>**0636900000**||
|---|---|---|
||FM 4.2<br>Hole ø 4.2 mm<br>40<br>**1724580000**||
|**MOFU 35/LO/1**<br>**MOFU 35**<br>**MB**<br>4s Aehiss <br>s0<br>6—},! <br>_<br>5.5<br>BY<br>a 58I<br>Y=)|**Mounting foot, PA orange for TS 35**<br>MOFU 35/LO/1<br>with holes<br>20<br>**0646260000**<br>MOFU 35<br>20<br>**0495660000**<br>**Sliding nut for TS 32**<br>**Colour**<br>MB M3/M5<br>M3 und M5<br>creme<br>20<br>**0503500000**<br> ~~a~~<br>~~==——l|~~<br> ~~a~~<br>~~==~~||
||MB M5/M3<br>M5 und M3<br>black<br>20<br>**0553400000**||
||MB M6/M4<br>M6 und M4<br>grey<br>20<br>**0334900000**||
|_<br>ef<br>SSS<br>|) LESClll<br>32<br>a|The sliding nut for the RS 32 terminal rail has<br>two threaded holes for screws M3 + M5 / M6 + M4 / M5 + M3.<br>It is used to fasten components which cannot be slotted<br>directly onto the TS 32, in particular the smaller TS 15 top hat rail.<br>This enables, for example, mini-terminals to be snapped<br>onto the TS 15 first, and this rail is then fastened together<br>with the terminals to the TS 32 using the sliding nut.||
**H.15**
**H**
**H.16**
**Contents**
## Accessories
## **Accessories**
|**Accessories**||
|---|---|
|Overview|I.2|
|Visual separation – side covers|I.4|
|Colour coding options|I.6|
|Potential distribution|I.8|
|Testing/Checking|I.14|
|Protective covers|I.16|
|Accessories for modular disconnect test terminals|I.20|
**I**
**I.1**
**Overview**
**I**
## The extra functions
Weidmüller can supply an extensive range of accessories for users of the SAK series of modular terminals. These help to provide the right solution for all manner of tasks, even those outside the scope of standard functions. And of course, the accessories have to satisfy the same high standards of quality as the modular terminals themselves.
**I.2**
**Overview**
**Visual separation – side covers** Page I.4
To guarantee protection against fingers coming into contact with live parts when working with modular terminals, open sides are blocked off with end cover plates and partition plates. But in addition, end cover plates and partition plates are available in various colours and so can be used to create a visual distinction between different circuits.
## **Testing / Checking**
Page I.14
Weidmüller test plugs and sockets guarantee that the necessary tests can be carried out on the installation.
**Colour coding options**
**==> picture [27 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Page I.6<br>**----- End of picture text -----**<br>
Another helpful feature of the accessories for modular terminals with screw connections are the different colours available.
**Protective covers**
Page I.16
Electrical installations must be safe at all times. Therefore, Weidmüller can supply a large range of protective cover strips and plates, plus labelling systems.
**Potential distribution**
Page I.8
Some 60% of all modular terminals are cross connected. Weidmüller can supply a wide range of solutions.
## **Accessories for modular**
**disconnect test terminals** Page I.20
Special applications call for special solutions.
**I**
**I.3**
**Visual separation – side covers**
## **End cover plates**
Apart from a few exceptions, the last terminal of a terminal strip must be covered with an AP end cover plate. And end cover plates are also required within a terminal strip containing terminals of different sizes.
The overall dimensions of the end cover plates match the sizes of the associated terminals. The end cover plate is held in place by an end bracket.
## **AP end cover plates**
|**AP end cover plates**||
|---|---|
|**Type**<br>**Order No.**<br>AP<br>**0150960000**<br>AP 2.5<br>KrG<br>**0279520000**<br>AP 2.5<br>KrS<br>**0279530000**<br>AP<br>KrG<br>**0117920000**<br>AP 16<br>KrG<br>**0271120000**<br>AP 16<br>PA<br>**0271160000**|**for terminal type:**<br>SAKD 2.5 N<br>SAK 2.5 and TT<br>SAK 2.5 L and LL<br>SAK 4, 6 N, 10, SAKC 4, NT 2, SLK 1, SAK 4 S and SS<br>SAK 16|
|AP 35<br>KrG<br>**0303620000**|SAK 35, 35 N|
|AP 35<br>PA<br>**0303660000**||
|AP 70<br>KrG<br>**0340920000**<br>AP 70<br>PA<br>**0340960000**<br>AP 95<br>KrG<br>**0550920000**<br>AP 2.5<br>KrG<br>**0309220000**<br>AP<br>PA<br>**0438560000**<br>AP<br>KrG<br>**0266420000**<br>AP<br>KrG<br>**0298120000**<br>AP<br>PA<br>**0582560000**<br>AP<br>PA<br>**0483460000**|SAK 70<br>SAK 95<br>SAK 2.5 L<br>DK 4/380 Q<br>AST 1, 5 and 5 T<br>AST 3 and 4<br>AST 6, TOP 2.5<br>TOP 4 SF / FF|
|AP<br>KrG<br>**0294420000**|AKZ 4|
|AP<br>PA<br>**0294460000**|AKZ 4 S and SS, AKZ 4, AKZ 4 L and LL, AKZ 4 T|
|AP<br>KrG<br>**0146720000**|SAKT 1, SAKC 10, SAKB 10, SAKS 7|
|AP<br>KrG<br>**0329120000**|SAKT 2|
|AP<br>PA<br>**0211360000**|SAKR, SAKRL, SAKRD|
|AP<br>KrG<br>**0134220000**|SAKA 10|
|AP<br>KrG<br>**0191320000**|SAKS 1 and 3|
|AP<br>PA<br>**0340560000**|AKZ 1.5, AKZ 1.5 T|
|AP<br>PA<br>**0329660000**|AKZ 1.5 W|
|AP<br>KrS<br>**0131730000**|SAKH 6 10|
**I**
**End clamp plates**
**EP end clamp plates for SAKG**
|**End clamp plates**|**End clamp plates**|**End clamp plates**|**EP end clamp plates for SAKG**||
|---|---|---|---|---|
|Dimensions (mm)<br>~~a~~<br>b<br>~~So ~~<br>~~_~~|||**Material**<br>**Thickness**<br>**a**<br>**b**<br>**Order No.**<br>for mounting on TS 32<br>HP<br>2<br>120<br>75.5<br>**0205100000**<br>HP T*<br>2<br>120<br>75.5<br>**0205200000**<br>HP<br>2<br>160<br>90.5<br>**0205300000**<br>HP T*<br>2<br>160<br>90.5<br>**0205400000**<br>for mounting on TS 35<br>HP<br>2<br>120<br>75.5<br>**0180500000**<br>HP T*<br>2<br>120<br>75.5<br>**0180600000**<br>HP<br>2<br>160<br>90.5<br>**0180700000**<br> ~~——~~|**for terminal type:**<br>SAKG 28, 32 II, 70<br>SAKG 32 I + III,<br>40, 46, 54<br>SAKG 32 II, 70<br>SAKG 32 I + III,|
||||HP T*<br>2<br>160<br>90.5<br>**0180800000**|40, 46, 54|
||||T* = suitable for tropical applications||
**I.4**
**Visual separation – side covers**
## **End clamp plates EP end clamp plates**
**End clamp plate with mounting bracket EP ... /32**
**==> picture [407 x 120] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|End clamp plate with mounting|Type|a|b|Order No.|for terminal type:|
|bracket EP ... /32|EP 1|120|75.5|0271800000|SAKG 28 and SAKG 70|
|EP 2|160|90.5|0271900000|SAKG 32, 40, 46 and 54|
|EP 1/35|120|76.5|1381600000|SAKG 32 and SAKG 70|
|EP 2/35|160|91.5|0182000000|SAKG 32, 40, 46 and 54|
|+|
|]|
|||
|joie|
|End clamp plate with mounting|
|bracket EP ... /35|
**----- End of picture text -----**<br>
## **Strain relief clip**
**==> picture [157 x 28] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|ZU 1|
|Material|Qty.|Order No.|
|ZU 1|2|0240600000|
**----- End of picture text -----**<br>
**I**
Strain relief clip for gripping cables up to 30 mm dia. Attach the strain relief clip between TS and mounting surface using the TS fixing screw. Fit the spacer to suit with the second fixing screw.
**I.5**
**Colour coding options**
**I**
## **End cover plates**
## **Visual separation – side covers**
||**Type**<br>**Colour**<br>**Qty.**<br>**Order No.**<br>AP SAK410 DB<br>dark beige<br>20<br>**0105100000**<br>AP SAK410 OR<br>orange<br>20<br>**0105160000**<br>AP ASK1 OR<br>orange<br>20<br>**0105360000**<br>AP DKT4 PA<br>beige<br>20<br>**0687560000**<br>AP AKZ2.5K<br>beige<br>50<br>**0697260000**<br>AP AKZ2.5<br>beige<br>50<br>**0697360000**|**Type**<br>**Colour**<br>**Qty.**<br>**Order No.**<br>AP SAK35 KRG<br>dark beige<br>10<br>**0303620000**<br>AP AKZ2.5 BL<br>blue<br>50<br>**0697380000**<br>AP RSF2 KRG<br>dark beige<br>10<br>**0301420000**<br>AP SAK2.5<br>beige<br>20<br>**0279560000**<br>AP SAK2.5 KRG<br>dark beige<br>20<br>**0279520000**<br>AP DLD2.5 BL<br>blue<br>20<br>**1317680000**|
|---|---|---|
||AP DKIT4<br>beige<br>20<br>**0635060000**|AP AKZ1.5W<br>beige<br>20<br>**0329660000**|
||AP SAK410 RT<br>red<br>20<br>**0117900000**|AP SAKT2 KRG<br>dark beige<br>20<br>**0329120000**|
||AP SAK410 KRG/BL<br>blue<br>20<br>**0117970000**|AP AST3+4 KRG<br>dark beige<br>20<br>**0298120000**|
||AP SAK410 BL<br>blue<br>20<br>**0117980000**|AP DK4Q BL<br>blue<br>20<br>**1397180000**|
||AP SAKH 4EX<br>black<br>20<br>**0408730000**|AP SAK2.5L KRG<br>dark beige<br>20<br>**0309220000**|
||AP SAKH610 EP/SW<br>black<br>20<br>**0131700000**|AP RSF3<br>beige<br>10<br>**0270460000**|
||AP DUSA4/35<br>beige<br>20<br>**0401360000**|AP RSF1 KRG<br>dark beige<br>10<br>**0270420000**|
||AP SAKB/C/T BE<br>beige<br>20<br>**0146760000**|AP AST1+5 KRG<br>dark beige<br>20<br>**0266420000**|
|**Protection against contact with live parts**<br>Apart from a few exceptions, the last terminal<br>of a terminal strip must be covered with an AP<br>end cover plate. And end cover plates are also<br>required within a terminal strip containing<br>terminals of different sizes.<br>This guarantees protection against contact with<br>live parts. The modular terminals are fingertouch|AP SAKD2.5N BL<br>blue<br>20<br>**0150980000**<br>AP AKA2.5 KRG/BL<br>blue<br>50<br>**0162570000**<br>AP SAK410 KRG/DB<br>dark beige<br>20<br>**0177600000**<br>AP SAKS1+3 KRG/DB<br>dark beige<br>20<br>**0191300000**<br>AP SAKR BE<br>beige<br>20<br>**0211360000**<br>AP 70 SAK70 KRG<br>dark beige<br>10<br>**0340920000**<br>AP SAKR BL<br>blue<br>20<br>**0211380000**<br>AP AKZ1.5<br>beige<br>50<br>**0340560000**|AP AST1+5<br>beige<br>20<br>**0266460000**<br>AP SAK16 KRG<br>dark beige<br>20<br>**0271120000**<br>AP SAKT4 KRG<br>dark beige<br>20<br>**0244920000**<br>AP SAK16<br>beige<br>20<br>**0271160000**<br>AP SAK410<br>beige<br>20<br>**0117960000**<br>AP SAK410 KRG<br>dark beige<br>20<br>**0117920000**<br>AP SAK410 I<br>beige<br>20<br>**0117910000**<br>AP ASK1 DB<br>dark beige<br>20<br>**1753320000**|
|safe (to DIN VDE 0106100).|AP SAK70/35<br>beige<br>10<br>**0340960000**|AP 100 GR<br>grey<br>20<br>**1773410000**|
||AP AST1+5 DB<br>dark beige<br>20<br>**0266400000**|AP DLI2.5 DB<br>dark beige<br>20<br>**1783550000**|
|**Visual separation**|AP ASK1<br>beige<br>20<br>**0380360000**|AP DLD2.5/PE DB<br>dark beige<br>20<br>**1783800000**|
|Coloured end cover plates are frequently used|AP SAK16 BL<br>blue<br>20<br>**0271180000**|AP VLI1.5 DB<br>dark beige<br>20<br>**1784150000**|
|to create a visual distinction between different|AP DK4<br>beige<br>20<br>**0359260000**|AP VLI1.5/PE DB<br>dark beige<br>20<br>**1784160000**|
|circuits|AP SAK2.5 GE<br>yellow<br>20<br>**0279500000**|AP DLD2.5 DB<br>dark beige<br>20<br>**1784210000**|
||AP SAK2.5 OR<br>orange<br>20<br>**0279540000**|AP 110 GR<br>grey<br>10<br>**1790080000**|
|**Guaranteeing the operating voltage**<br>End cover plates can also be used to maintain<br>the necessary clearance and creepage values<br>and thus guarantee the operating voltage for the<br>application. For example, if crossconnection sets<br>are positioned directly adjacent one another.<br>**Matching profiles**|AP SAK2.5 KRG BL<br>blue<br>20<br>**0279570000**<br>AP SAK2.5 BL<br>blue<br>20<br>**0279580000**<br>AP AKZ4 BL<br>blue<br>20<br>**0294480000**<br>AP SAK95 KRG<br>blue<br>10<br>**0550920000**<br>AP DSK1.5<br>beige<br>20<br>**0532960000**<br>AP SAK35 KRG/BL<br>blue<br>10<br>**0303670000**<br>AP DK4S<br>beige<br>20<br>**0631360000**<br>AP SAK35/TW SAK16 BL blue<br>10<br>**0303680000**|AP SAKR BE RSSET<br>beige<br>5<br>**1820200000**<br>AP SAK410 GR 7042<br>grey<br>20<br>**1853970000**<br>AP 2 DSG1.5T<br>beige<br>1<br>**2119490000**<br>AP PPT/35<br>black<br>10<br>**3835120000**<br>AP RV<br>beige<br>1<br>**4145220000**<br>AP OSC 10/16<br>beige<br>10<br>**9154850000**<br>AP OSC 4<br>beige<br>10<br>**9154860000**<br>AP STA2.5 0.5MM<br>beige<br>1<br>**2012770000**|
|The overall dimensions of the end cover plates|AP SAK2.5L KRG BL<br>blue<br>20<br>**0309270000**|AP KDKS1 1.5<br>beige<br>20<br>**9503330000**|
|match the sizes of the associated terminals.|AP ADK1<br>beige<br>50<br>**0476260000**|AP KDKS1 EN<br>beige<br>20<br>**9503340000**|
||AP AKZ1.5 BL<br>blue<br>50<br>**0340580000**|AP KSKM<br>beige<br>20<br>**9509630000**|
|**Installation**<br>Spigots on the end cover plate enable it to be<br>simply clipped into the corresponding modular<br>terminal. The matching holes in the modular<br>terminal ensure that the end cover plate is<br>positioned exactly to match the profile of the|AP SAK2.5/35 + AST3+4 beige<br>20<br>**0460560000**<br>AP TOP4SFFF<br>beige<br>20<br>**0483460000**<br>AP DK4 BL<br>blue<br>20<br>**0359280000**<br>AP ASK1 RT<br>red<br>20<br>**0380350000**<br>AP ASK1 BL<br>blue<br>20<br>**0380380000**<br>AP DLD2.5/PE<br>beige<br>20<br>**1595960000**|AP SAK410 GE<br>yellow<br>1<br>**2076890000**<br>AP SAK16 GE<br>yellow<br>1<br>**2076900000**<br>AP SAK35/TW SAK16 GE yellow<br>1<br>**2076910000**<br>AP AST3+4/35 GE<br>yellow<br>1<br>**2077060000**<br>AP AKZ4 GE<br>yellow<br>50<br>**2077070000**<br>AP SAK2.5/35<br>beige<br>1<br>**2144900000**|
|terminal.|AP VLI1.5/PE<br>beige<br>20<br>**1633320000**|AP ATA1<br>beige<br>1<br>**2093550000**|
||AP VLI1.5<br>beige<br>20<br>**1633260000**|AP SAK4 KRG M.FU<br>dark beige<br>20<br>**0460020000**|
||AP MAK2.5<br>beige<br>20<br>**1615280000**|AP DK4/380 Q<br>beige<br>20<br>**0438560000**|
|| <br>4<br>im|AP DK4Q<br>beige<br>20<br>**1397160000**<br>AP DLI2.5<br>beige<br>20<br>**1313260000**<br>AP DLD2.5<br>beige<br>20<br>**1317660000**<br>AP ST5 PPO/SW<br>black<br>10<br>**0447240000**<br>AP ST5 PA/BE<br>beige<br>10<br>**0447260000**<br>AP SAK2.5/35 DB<br>dark beige<br>20<br>**0460490000**<br>AP TW/SS.../35<br>beige<br>10<br>**1333200000**<br>AP SAK2.5/35 BL<br>blue<br>20<br>**0460580000**<br>AP SAKS1+3 KRG<br>dark beige<br>20<br>**0191320000**<br>AP SAKD2.5N<br>beige<br>20<br>**0150960000**<br>AP SAKR KRG<br>dark beige<br>20<br>**0211320000**<br>AP TAL<br>beige<br>20<br>**0212260000**<br>AP SAKA KRG<br>dark beige<br>20<br>**0134220000**<br>AP SAK95 KRG/BL<br>blue<br>10<br>**0550970000**<br>AP SAKH610 KRG<br>dark beige<br>20<br>**0131720000**<br>AP SAKB/C/T BE<br>beige<br>1<br>**4140450000**<br>AP SAKB/C/T1 DB<br>dark beige<br>1<br>**4173520000**<br>AP MAK2.5 DB<br>dark beige<br>20<br>**7917000000**<br>AP SAKK4/10 KER/WS<br>white<br>10<br>**9502630000**<br>AP KDKS1 1.5 DB<br>dark beige<br>20<br>**9532470000**<br> ~~llas~~<br>~~==—~~<br>~~es |~~<br>~~—F~~||
||AP SAKB/C/T KRG<br>dark beige<br>20<br>**0146720000**||
||AP AKA2.5<br>beige<br>100<br>**0162520000**||
||AP DK4Q DB<br>dark beige<br>20<br>**0631300000**||
||AP DK4S BL<br>blue<br>20<br>**0631380000**||
||AP AKZ4<br>blue<br>20<br>**0294460000**||
||AP AKZ4 KRG<br>dark beige<br>20<br>**0294420000**||
||AP SAK35/TW SAK16<br>beige<br>10<br>**0303660000**||
**I.6**
**Colour coding options**
## **Colour coding options**
The colours listed here are available as standard. Other types of terminals in custom colours can be supplied on request, provided a minimum quantity is ordered.
|**Type**<br>**Colour**<br>**Qty.**<br>**Order No.**<br>SAK 2.5 AL BLUE(E)<br>blue<br>100<br>**6253140000**<br>SAK 2.5 BL<br>blue<br>100<br>**0279680000**<br>SAK 2.5 BL RSSET blue<br>10<br>**1817860000**<br>SAK 2.5 KRG/BL<br>blue<br>100<br>**0279670000**<br>SAK 2.5 OR<br>orange<br>100<br>**1326360000**<br>SAK 2.5 SW 1X1<br>black<br>100<br>**0108560000**<br>**Type**<br>**Colour**<br>**Qty.**<br>**Order No.**<br>SAKH 10 EP/SW<br>black<br>50<br>**0126700000**<br>SAKH 35 EP/SW<br>black<br>20<br>**1596240000**<br>SAKR 2STB BL<br>blue<br>100<br>**0412280000**<br>SAKR BL<br>blue<br>100<br>**0412180000**<br>SAKR OR<br>orange<br>100<br>**1461960000**<br>SAKR/35 2STB BL<br>blue<br>100<br>**0183380000**<br>~~_~~<br>~~--_—=s—r—=—i—_Urd “ds's‘(‘(asé‘_adc~~~c~~=_~~<br>~~.~~<br>~~&»&»:»:»&«O~~<br>~~O~~<br>~~#£«©;,z|,}24=~~|**Type**<br>**Colour**<br>**Qty.**<br>**Order No.**<br>SAK 2.5 AL BLUE(E)<br>blue<br>100<br>**6253140000**<br>SAK 2.5 BL<br>blue<br>100<br>**0279680000**<br>SAK 2.5 BL RSSET blue<br>10<br>**1817860000**<br>SAK 2.5 KRG/BL<br>blue<br>100<br>**0279670000**<br>SAK 2.5 OR<br>orange<br>100<br>**1326360000**<br>SAK 2.5 SW 1X1<br>black<br>100<br>**0108560000**<br>**Type**<br>**Colour**<br>**Qty.**<br>**Order No.**<br>SAKH 10 EP/SW<br>black<br>50<br>**0126700000**<br>SAKH 35 EP/SW<br>black<br>20<br>**1596240000**<br>SAKR 2STB BL<br>blue<br>100<br>**0412280000**<br>SAKR BL<br>blue<br>100<br>**0412180000**<br>SAKR OR<br>orange<br>100<br>**1461960000**<br>SAKR/35 2STB BL<br>blue<br>100<br>**0183380000**<br>~~_~~<br>~~--_—=s—r—=—i—_Urd “ds's‘(‘(asé‘_adc~~~c~~=_~~<br>~~.~~<br>~~&»&»:»:»&«O~~<br>~~O~~<br>~~#£«©;,z|,}24=~~|**Type**<br>**Colour**<br>**Qty.**<br>**Order No.**<br>SAK 2.5 AL BLUE(E)<br>blue<br>100<br>**6253140000**<br>SAK 2.5 BL<br>blue<br>100<br>**0279680000**<br>SAK 2.5 BL RSSET blue<br>10<br>**1817860000**<br>SAK 2.5 KRG/BL<br>blue<br>100<br>**0279670000**<br>SAK 2.5 OR<br>orange<br>100<br>**1326360000**<br>SAK 2.5 SW 1X1<br>black<br>100<br>**0108560000**<br>**Type**<br>**Colour**<br>**Qty.**<br>**Order No.**<br>SAKH 10 EP/SW<br>black<br>50<br>**0126700000**<br>SAKH 35 EP/SW<br>black<br>20<br>**1596240000**<br>SAKR 2STB BL<br>blue<br>100<br>**0412280000**<br>SAKR BL<br>blue<br>100<br>**0412180000**<br>SAKR OR<br>orange<br>100<br>**1461960000**<br>SAKR/35 2STB BL<br>blue<br>100<br>**0183380000**<br>~~_~~<br>~~--_—=s—r—=—i—_Urd “ds's‘(‘(asé‘_adc~~~c~~=_~~<br>~~.~~<br>~~&»&»:»:»&«O~~<br>~~O~~<br>~~#£«©;,z|,}24=~~|
|---|---|---|
||SAK 2.5 SW 1X1/KRG<br>black<br>100<br>**0108520000**|SAKR/35 BL<br>blue<br>100<br>**0172180000**|
||SAK 2.5/35 BL<br>blue<br>100<br>**0380480000**|SAKR/35 WS<br>white<br>100<br>**0172190000**|
||SAK 2.5/35 DBL<br>blue<br>100<br>**1799920000**||
||SAK 2.5/35 GE<br>yellow<br>100<br>**1821480000**||
||SAK 2.5/35 KRG/BL<br>blue<br>100<br>**0380470000**||
||SAK 2.5/35 OR<br>orange<br>100<br>**0380440000**||
||SAK 2.5/35 RT<br>red<br>100<br>**1799910000**||
||SAK 2.5/35 SW<br>black<br>100<br>**1799900000**||
||SAK 2.5/35 SW 1X1<br>black<br>100<br>**0514060000**||
||SAK 2.5/EN BL<br>blue<br>100<br>**0218680000**||
||SAK 2.5/EN BR<br>brown<br>100<br>**1858450000**||
||SAK 2.5/EN SW<br>black<br>100<br>**1858440000**<br>SAK 2.5/EN WS<br>white<br>100<br>**1858460000**<br>SAK 2.5/TC AL BL<br>blue<br>100<br>**0107180000**<br>SAK 2.5/TC CH BL<br>blue<br>100<br>**0107280000**<br>SAK 35/35 BL<br>blue<br>20<br>**0380780000**||
||SAK 35/EN BL<br>blue<br>20<br>**1784400000**||
||SAK 4 BL<br>blue<br>100<br>**0128380000**||
||SAK 4 BL RSSET<br>blue<br>10<br>**1817780000**||
||SAK 4 EP/SW<br>black<br>100<br>**0128300000**||
||SAK 4 KRG BL<br>blue<br>100<br>**0128370000**||
||SAK 4 OR<br>orange<br>100<br>**0105060000**||
||SAK 4 SS/35 6.3 GR<br>grey<br>100<br>**0646930000**||
||SAK 4/35 BL<br>blue<br>100<br>**0443680000**||
||SAK 4/35 KRG/BL<br>blue<br>100<br>**0443670000**||
||SAK 4/35 OR<br>orange<br>100<br>**1323660000**||
||SAK 4/35/AP GG<br>green/yellow<br>100<br>**0443650000**||
||SAK 4/EN BL<br>blue<br>100<br>**0467480000**||
||SAK 4/EN BR<br>brown<br>100<br>**9130990000**||
||SAK 4/EN GE<br>yellow<br>100<br>**9129930000**||
||SAK 4/EN GN<br>green<br>100<br>**9129950000**||
||SAK 4/EN GR<br>grey<br>100<br>**9129960000**||
||SAK 4/EN GR 7042<br>grey<br>100<br>**1853950000**||
||SAK 4/EN OR<br>orange<br>100<br>**0467400000**||
||SAK 4/EN RT<br>red<br>100<br>**9129920000**||
||SAK 4/EN SW<br>black<br>100<br>**9130980000**||
||SAK 4/EN WS<br>white<br>100<br>**1773340000**||
||SAK 6/35 BL<br>blue<br>100<br>**0380580000**||
||SAK 6/35 GN/GE<br>yellow<br>100<br>**1866850000**||
||SAK 6/35 KRG/BL<br>blue<br>100<br>**0380570000**||
||SAK 6/EN BL<br>blue<br>100<br>**0212880000**||
||SAK 6/EN GE<br>yellow<br>100<br>**1772820000**||
||SAK 6/EN OR<br>orange<br>100<br>**1772810000**||
||SAK 6/EN RT<br>red<br>100<br>**0212840000**||
||SAK 6/EN SW<br>black<br>100<br>**0212810000**||
||SAK 6/EN WS<br>white<br>100<br>**1773350000**||
||SAK 6N BL<br>blue<br>100<br>**0193280000**||
||SAK 10 BL<br>blue<br>100<br>**0110080000**||
||SAK 10 KRG/BL<br>blue<br>100<br>**0110070000**||
||SAK 10 OR<br>orange<br>100<br>**0110040000**||
||SAK 10/35 BL<br>blue<br>100<br>**0443780000**||
||SAK 10/35 KRG/BL<br>blue<br>100<br>**0443770000**||
||SAK 10/EN BL<br>blue<br>100<br>**1784410000**||
||SAK 10/EN GR RAL 7042 grey<br>100<br>**1853960000**||
||SAK 10/EN OR<br>orange<br>100<br>**1772830000**||
||SAK 10/EN SW<br>black<br>100<br>**1773900000**||
||SAK 16 BL<br>blue<br>50<br>**0271080000**||
||SAK 16/35 BL<br>blue<br>50<br>**0380680000**||
||SAK 16/EN BL<br>blue<br>50<br>**1784390000**||
||SAK 70 KRG/BL<br>blue<br>10<br>**0340870000**||
||SAK 95/35 KRG/BL<br>blue<br>10<br>**0662270000**||
||SAKC 4/2STB7 BL<br>blue<br>100<br>**0340670000**||
||SAKD 2.5/35 BL<br>blue<br>100<br>**0268880000**||
||SAKD 2.5N BL<br>blue<br>100<br>**0215580000**||
||SAKH 6 EP/SW<br>black<br>50<br>**0126600000**||
**I**
**I.7**
**Potential distribution**
## Cross-connection systems
**I**
## **Cross-connections across more than 10 modular terminals**
The SAKD 2.5 N, SAK 2.5, SAK 4 and SAK 6 N terminals include the option of setting up a crossconnection with more than 10 poles, e.g. 20pole: 2 No. Q 10 + 1 No. QL 2.
The end fixing screws are removed from the Q 10 links by unscrewing them from the VH sleeves. The QL 2 is positioned between these and the two fixing screws screwed into their VH sleeves again. This arrangement allows 20 poles to be crossconnected.
## **Q pre-assembled cross-connectors**
The preassembled crossconnector has the appropriate number of cross connection links, crossconnection sleeves and fixing screws to match the number of poles required already installed in a captive arrangement. Such pre assembled crossconnectors merely have to be inserted into the appropriate terminals during installation. These cross connectors can be supplied in 2, 3, 4 and 10pole versions.
## **QL cross-connection links**
Crossconnection links are used to provide crossconnections with equal potential across several modular terminals. The crossconnection links are made from copper or brass with an electroplated tin coating, and can be supplied in lengths to suit 2, 3, 4 and 10 poles, to match the respective terminal width. The electrical connection between the crossconnection link and the busbar of the modular terminal is by way of a connecting sleeve.
## **BS fixing screws**
A steel fixing screw is used to connect the crossconnection link to the connecting sleeve on the busbar under a modular terminal. It is the purpose of the steel screw to provide a secure mechanical fixing between the cross connection and the busbar. Two types of screw are used: form A has a full length thread, and form B has a plain shaft below the head with a captive washer.
## **VH connecting sleeves**
The length of the connecting sleeve is matched to the size of the terminal. The sleeves are made from tincoated copper or brass. One connecting sleeve must be used for every terminal to be cross connected.
**I.8**
**Potential distribution**
**I**
## **Cross-connection systems**
||Form||
|---|---|---|
|**A B**|**A B**|**A B**|
|SAK 2.5|24 A|Q 2<br>**0370000000**<br>QL 2<br>**0155900000**<br>6<br>0.6<br>6<br>3.4<br>2.4|32 A|VH 8<br>**0266700000**<br>8<br>4.9<br>3.2|**0359000000**<br>B<br>3 x15|
|---|---|---|---|---|---|
|||Q 3<br>**3710000000**<br>QL 3<br>**0156000000**|32 A|||
|||Q 4<br>**3720000000**<br>QL 4<br>**0156100000**|32 A|||
|||Q 10<br>**0368700000**<br>QL 10<br>**0338100000**|32 A|||
|SAK 4|32 A|Q 2<br>**0336700000**<br>QL 2<br>**0130600000**<br>6<br>0.6<br>6.5<br>3.4<br>2.5|41 A|VH 13.5 **0248500000**<br>13.5<br>5<br>3.2|**0303000000**<br>B<br>3x20|
|||Q 3<br>**0336800000**<br>QL 3<br>**0130700000**|41 A|||
|||Q 4<br>**0336900000**<br>QL 4<br>**0130800000**|41 A|||
|||Q 10<br>**0368800000**<br>QL 10<br>**0338200000**|36 A|||
|SAK 6 N|41 A|Q 2<br>**0456700000**<br>QL 2<br>**0194300000**<br>6<br>1<br>8<br>3.4<br>3|41 A|VH 12<br>**0249000000**<br>12<br>5<br>3.2|**0303000000**<br>B<br>3x20|
|||Q 3<br>**0456800000**<br>QL 3<br>**0194400000**|41 A|||
|||Q 4<br>**0456900000**<br>QL 4<br>**0194500000**|41 A|||
|||Q 10<br>**0457000000**<br>QL 10<br>**0338300000**|41 A|||
|SAK 10|57 A|Q 2<br>**0457100000**<br>QL 2<br>**0470300000**<br>6<br>2<br>10<br>3.4<br>3.5|57 A|VH 12<br>**0249000000**<br>12<br>5<br>3.2|**0303000000**<br>B<br>3x20|
|||Q 3<br>**0457200000**<br>QL 3<br>**0470400000**|57 A|||
|||Q 4<br>**0457300000**<br>QL 4<br>**0470500000**|57 A|||
|||Q 10<br>**0457400000**<br>QL 10<br>**0470600000**|57 A|||
|SAK 16|76 A|Q 2<br>**0457500000**<br>QL 2<br>**0470700000**<br>6<br>2<br>12<br>3.4<br>4|76 A|VH 12<br>**0249000000**12<br>5<br>3.2|**0303000000**<br>B<br>3x20|
|||Q 3<br>**0457600000**<br>QL 3<br>**0470800000**|76 A|||
|||Q 4<br>**0457700000**<br>QL 4<br>**0470900000**|76 A|||
|||Q 10<br>**0457800000**<br>QL 10<br>**0471000000**|76 A|||
|SAK 35 N|125 A|QL 2<br>**0564900000**<br>8<br>3<br>16<br>4.5<br>5|99 A|VH 17<br>**0267000000**17<br>8<br>5|**0267100000**<br>A<br>4x30|
|||QL 3<br>**0565000000**|99 A|||
|||QL 4<br>**0565100000**|99 A|||
|||QL 10<br>**0565200000**|99 A|||
|SAK 35|125 A|QL 2<br>**0123600000**<br>8<br>3<br>18<br>4.5<br>5|99 A|VH 17<br>**0267000000**17<br>8<br>5|**0267100000**<br>A<br>4x30|
|||QL 3<br>**0123700000**|99 A|||
|||QL 4<br>**0123800000**|99 A|||
|||QL 10<br>**0338600000**|99 A|||
|SAK 70|192 A|QL 2<br>**0345300000**<br>14<br>4<br>22<br>5.5<br>7|180 A|VH 30.5 **0345500000**<br>30.5<br>11<br>5.5|**0345600000**<br>A<br>5x45|
|||QL 3<br>**0167000000**|180 A|||
|SAK 95|232 A|QL 2<br>**0551200000**<br>14<br>4<br>28<br>6<br>7|180 A|VH 35<br>**0551100000**<br>35<br>11<br>5.5|**0630200000**<br>B<br>5x50|
|||QL 3<br>**0407600000**|180 A|||
|||QL 4<br>**0407700000**|180 A|||
|SAKS 1|6,3 A|QL 2<br>**0191400000**<br>6<br>2<br>12.9<br>3.4<br>3|47 A||**0346200000**B<br>3 x 6|
|SAKS 3|10 A|QL 3<br>**0191500000**|47 A|||
|SAKS 6|10 A|QL 4<br>**0191600000**|47 A|||
|SAKS 7|10 A|QL 10<br>**0338800000**|36 A|||
|SAKS 4|16 A|QL 2<br>**0328000000**<br>10<br>4<br>24<br>4.8<br>5|47 A||**0199700000**A<br>3 x 7|
|||QL 3<br>**0328100000**|47 A||**0103300000**A<br>4 x 9|
|||QL 4<br>**0328200000**|47 A|||
|||QL 10<br>**0339000000**|36 A|||
|SAKS 2|10 A|QL 2<br>**0207800000**<br>10<br>4<br>27.6<br>4.8<br>6.5|47 A||**0103300000**A<br>4 x 9|
|SAKS 5|63 A|QL 3<br>**0207900000**|47 A|||
|||QL 4<br>**0208000000**|47 A|||
|||QL 10<br>**0338900000**|36 A|||
|DK 4 Q|41 A|Q 2<br>**0336400000**<br>QL 2<br>**0297200000**<br>4<br>0.8<br>6.1<br>2.8<br>2.5|32 A|VH 5<br>**0296800000**<br>5<br>4<br>2.7|**0400100000**<br>B<br>2.5x11|
|DKB 4 Q/10|41 A|Q 3<br>**0336500000**<br>QL 3<br>**0297300000**|32 A|||
**I.9**
**Potential distribution**
## **Cross-connection systems**
**Cross-connections between terminals of different sizes to increase the cross-section**
**I**
**==> picture [147 x 143] intentionally omitted <==**
**----- Start of picture text -----**<br>
8 9 6 5 4<br>3<br>7<br>1<br>2<br>**----- End of picture text -----**<br>
**==> picture [185 x 135] intentionally omitted <==**
**----- Start of picture text -----**<br>
6 7 8 5 4<br>11 10 9 3<br>1<br>2<br>**----- End of picture text -----**<br>
**==> picture [513 x 470] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal Position Type Order No. Current Terminal Position Type Order No. Current<br>from SAK 16 – 1 – – – von SAK 35 – 1 – – –<br>sleeve 3 VH 12 0249000000 – sleeve 3 VH 17 0267000000 –<br>screw 4 BS M 3 x 20 0303000000 – screw 4 BS M 4 x 30 0267100000 –<br>to SAK 6 N – 2 – – – washer 5 SS M 4 0136400000 –<br>crossconnection link 5 QL 2 0470300000 – zu SAK 10 N – 2 – – –<br>sleeve 6 VH 4,5 0303200000 – crossconnection link 5 QL 2 0207400000 47 A<br>screw 7 BS M 3 x 25 0292500000 – sleeve 6 VH 4,5 0303200000 –<br>washer 8 SS M 3 0164400000 – screw 8 BS M 3 x 35 0309800000 –<br>screw 9 BS M 3 x 20 0303000000 – washer 9 SS M 3 0164400000 –<br>sleeve 10 VH 12 0249000000 – zu SAK 6 N – 2 – – –<br>crossconnection link 11 QL 2 0194300000 47 A crossconnection link 6 QL 2 0207400000 47 A<br>crossconnection link 11 QL 3 0194400000 47 A sleeve 7 VH 27 0309400000 –<br>crossconnection link 11 QL 4 0194500000 47 A screw 8 BS M 3 x 35 0309800000 –<br>crossconnection link 11 QL 10 0338300000 36 A retaining screw 9 SS M 3 0164400000 –<br>to SAK 2.5 – 2 – – – von SAK 35 N – 1 – – –<br>crossconnection link 5 QL 2 0470300000 – sleeve 3 VH 17 0267000000 –<br>sleeve 6 VH 12 0249000000 – screw 4 BS M 4 x 30 0267100000 –<br>screw 7 BS M 3 x 30 0296200000 – retaining screw 5 SS M 4 0136400000 –<br>retaining screw 8 SS M 3 0164400000 – zu SAK 10 – 2 – – –<br>screw 9 BS M 3 x 15 0359000000 – crossconnection link 6 QL 2 0207400000 47 A<br>sleeve 3 VH 12.5 0308000000 – sleeve 7 VH 27 0309400000 –<br>sleeve 3 VH 8 0266700000 – screw 8 BS M 3 x 35 0309800000 –<br>crossconnection link 11 QL 2 0155900000 27 A retaining screw 9 SS M 3 0164400000 –<br>crossconnection link 11 QL 3 0156000000 27 A zu SAK6 N – 2 – – –<br>crossconnection link 11 QL 4 0156100000 27 A crossconnection link 6 QL 2 0135500000 47 A<br>crossconnection link 11 QL 10 0338100000 27 A sleeve 7 VH 27 0309400000 –<br>from SAK 10 – 1 – – – screw 8 BS M 3 x 35 0309800000 –<br>screw 4 BS M 3 x 20 0303000000 – retaining screw 9 SS M 3 0164400000 –<br>to SAK 4 – 2 – – – von SAK 10 – 1 – – –<br>sleeve 3 VH 13.5 0248500000 – sleeve 3 VH 12.5 0300800000<br>crossconnection link 5 QL 2 1443000000 – screw 4 BS M 3 x 20 0303000000 –<br>screw 7 BS M 3 x 20 0303000000 – retaining screw 5 SS M 3 included –<br>screw 9 BS M 3 x 20 0303000000 – zu SAK 35 N – 1 – – –<br>sleeve 10 VH 13.5 0248500000 – sleeve 3 VH 13 0304000000 –<br>crossconnection link 11 QL 2 0130600000 36 A screw 4 BS M 3 x 20 0303000000 –<br>crossconnection link 11 QL 3 0130070000 36 A washer 5 SS M 3 included –<br>crossconnection link 11 QL 4 0130800000 36 A zu SAK 2.5 – 2 – – –<br>crossconnection link 11 QL 10 0338200000 36 A crossconnection link 6 QL 2 0130600000 27 A<br>to SAK 2.5 – 2 – – – sleeve 7 VH 16 0309700000 –<br>crossconnection link 5 QL 2 0193400000 36 A screw 8 BS M 3 x 20 0303000000 –<br>sleeve 1 VH 13 0304000000 – retaining screw 9 SS M 3 included –<br>screw 4 + 7 BS M 3 x 20 0303000000 –<br>screw 9 BS M 3 x 15 0359000000 –<br>sleeve 10 VH 8 0266700000 –<br>crossconnection link 11 QL 2 0155900000 27 A<br>crossconnection link 11 QL 3 0156000000 27 A<br>crossconnection link 11 QL 4 0156100000 27 A<br>crossconnection link 11 QL 10 0338100000 27 A<br>sleeve 3 VH 13 0304000000 –<br>sleeve 3 VH 6.5 0286400000<br>**----- End of picture text -----**<br>
**I.10**
**Potential distribution**
**I**
## **Screw-in cross-connectors (Q)**
In this type of crossconnection the crossconnection link, connecting sleeves and fixing screws are preassembled in a captive arrange ment. However, all the individual parts are also available separately on request. During installation, these preassembled crossconnectors are simply inserted into the cross connection slot in the middle of the terminal and screwed tight. Any number of poles can be achieved by linking two cross connections. For example, a 20pole crossconnection by joining together two 10pole crossconnections with the crossconnection link of a 2pole crossconnection (see figure below)..
## **Q ... AKZ 4SS**
**==> picture [241 x 122] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Technical specification|
|continuous current, 2pole/multipole|A|32 / 32|
|thread size|M 2.5|
|tightening torque|Nm|0.4 ... 0.6|
|Ordering data|Type|Qty.|Order No.|
|2pole|Q...2 AKZ 4SS|0369000000|
|3pole|Q...3 AKZ 4SS|0369100000|
|4pole|Q...4 AKZ 4SS|0369200000|
|10pole|Q...10 AKZ 4SS|0369300000|
|24pole|
|for terminal|
|AKZ 4SS|
**----- End of picture text -----**<br>
## **Q ... DLI 2.5**
**==> picture [111 x 132] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|24 / 24|
|M 2.5|
|0.4 ... 0.6|
|Type|Qty.|Order No.|
|Q...2 DLI 2..5|1312500000|
|Q...3 DLI 2..5|1312600000|
|Q...4 DLI 2.5|1312700000|
|Q...10 DLI 2.5|1313100000|
|for terminal|
|DLI 2.5|
|DLA 2.5|
|DLD 2.5|
**----- End of picture text -----**<br>
**Q ... AKZ 1.5 Q ... AKZ 4**
**==> picture [372 x 131] intentionally omitted <==**
**----- Start of picture text -----**<br>
Technical specification<br>continuous current, 2pole/multipole A 24 / 24 32 / 32<br>thread size M 2.5 M 2.5<br>tightening torque Nm 0.4 ... 0.6 0.4 ... 0.6<br>Ordering data Type Qty. Order No. Type Qty. Order No.<br>2pole Q...2 AKZ 1.5 50 0368200000 Q...2 AKZ 4 50 0336400000<br>3pole Q...3 AKZ 1.5 50 0368300000 Q...3 AKZ 4 50 0336500000<br>4pole Q...4 AKZ 1.5 50 0368400000 Q...4 AKZ 4 50 0336600000<br>10pole Q...10 AKZ 1.5 20 0368500000 Q...10 AKZ 4 20 0338600000<br>24pole<br>for terminal for terminal<br>AKZ 1.5 AKZ 4<br>AKZ 2.5<br>**----- End of picture text -----**<br>
**I.11**
**Potential distribution**
## **Removable crossconnection links**
Removable crossconnection links are intended for 2pole, easily disconnected crossconnections. They are fitted together with a VH connecting sleeve and a BS fixing screw.
## **VL 2**
Removable crossconnection links
## **VH**
Connecting sleeves
## **BS**
Fixing screws
**for terminal Type Qty. Order No. Type Qty. Order No. Type Qty. Order No.** SAK 4 VL 2 50 **0197000000** VH 19 50 **0285100000** BS M3x25 100 **0292500000** SAK 6 N VL 2 50 **0194700000** VH 19 50 **0285100000** BS M3x25 100 **0292500000** SAK 10 VL 2 50 **0135900000** VH 19 50 **0285100000** BS M3x25 100 **0292500000** SAK 16 ~~—_~~ VL 2 50 **0135800000** ~~En a~~ VH 19 50 **0285100000** BS M3x25 100 **0292500000** SAK 35 VL 2 50 **0124000000** VH 24,5 50 **0298700000** BS M4x35 50 **0298900000**
**I**
## **Spacer pillars**
## **Spacer pillars type DS**
## **EW 35**
## **EWK 2**
The DS spacer pillars are made from a tempered insulating material and are used so that individual current paths can be disconnected by removing the fixing screw. The current in the cross connection is fed via the fixing screw in this arrangement. Therefore, we prescribe the use of screws made from CuNi 60 (a coppernickel alloy). The use of an end bracket with a screw holder avoids losing fixing screws that have been removed.
End bracket for TS 35 with End bracket for TS 32 with screw holder for fixing screws screw holder for fixing screws that have been removed. that have been removed.
**==> picture [335 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|for terminal|Type|Qty.|Order No.|Type|Qty.|Order No.|Type|Qty.|Order No.|
|SAK 2.5|DS 9*|100|0330930000|EW35/TS 35|20|0258660000|EWK 2/TS 32|20|0258760000|
|BS M 3x15 CuNi|with screw holder|with screw holder|
|100|0377200000|
|TT|SAK 4|ummm|DS 14*|100|0207530000|
|BS M 3x20 CuNi|
|SAK 6 N|DS 12.5*|100100|03771000000207730000|OT|
|BS M 3x20 CuNi|
|100|0377100000|
|SAK 10|DS 12.5*|100|0207630000|
|and SAK 16|BS M 3x20 CuNi|
|100|0377100000|
|CO|
|* Height|
|in mm|
**----- End of picture text -----**<br>
**==> picture [219 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
100 0377100000<br>el CO<br>**----- End of picture text -----**<br>
## **SH 2**
## **Rail holder**
For an insulated terminal rail arrangement in fully insulated installations.
**==> picture [154 x 43] intentionally omitted <==**
**----- Start of picture text -----**<br>
for terminal Type Qty. Order No.<br>EK 2.5 N, EK 2.5/35, SH2 10 0494920000<br>EK 4, EK 4/35, EK 6/35,<br>EK 10, EK 10/35, EK 16,<br>EK 16/35, EK 35,<br>EK 35/35<br>**----- End of picture text -----**<br>
**I.12**
**Potential distribution**
## **Cross-connection combs**
Crossconnection combs are fitted externally and enable current splitting at modular terminals that do not have a crossconnection slot in the middle of the terminal or that those where two potentials have to be fed in parallel. Types QB 2, 3 and 4 are insulated crossconnection combs. Types QB 58 and 75 are supplied in 58 and 75pole versions respectively.
The poles are easily broken out/off manually. Pushon insulation for subsequent shock protection is available for both pitches. When using such external crossconnectors, the rated crosssection is reduced to the next smaller conductor size.
**==> picture [53 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
QB 2, 2pole<br>QB 3, 3pole<br>QB 4, 4pole<br>QB 58pole, straight<br>QB 58pole, angled<br>QB 75pole, straight<br>QB 75pole, angled<br>black insulation<br>blue insulation<br>red insulation<br>**----- End of picture text -----**<br>
## **QB 2-, 3- and 4-pole**
## **QB 58, QB 75**
angled
Poles are easily broken off manually for clamping points that do not need to be crossconnected.
**==> picture [332 x 176] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Crossconnection comb|Crossconnection comb|
|insulated|uninsulated|(available with insulation as shock protection|
|pitch mm|pitch mm|on request)|
|8.0|6.0 and 6.5|pitch mm|pitch mm|
|8.0|6.0|
|e.g. SAK 6|e.g. SAK 2.5|
|QB 58|QB 75|
|Qty.|Order No.|Qty.|Order No.|Qty.|Order No.|Qty.|Order No.|
|50|0461100000|[1)]|50|0482700000|[1)]|
|50|0461200000|[1)]|50|0482800000|[1)]|
|50|0461300000|[1)]|50|0482900000|[1)]|
|10|0545400000|[1)2)]|
|10|0545300000|[1)2)]|
|10|0535200000|[1)2)]|
|10|0526400000|[1)2) ]|
|10|0546000000|10|0526700000|
|10|0546080000|10|0526780000|
|10|0546040000|10|0526760000|
**----- End of picture text -----**<br>
1) Currentcarrying capacity 27 A
2) The mounting tolerances of the terminals must be taken into account.
**I**
## **Plug-in cross-connectors type QS and DQS**
## **DQS 2**
## **QS 2**
für Steckbuchsen 2.3 mm Ø für Steckbuchsen 2.3 mm Ø
## **QS 2**
für Steckbuchsen 4 mm Ø belastbar bis 44 A
QS and DQS plugin crossconnectors are used in conjunction with sockets to create easily disconnected crossconnections between modular terminals.
**==> picture [4 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
y<br>**----- End of picture text -----**<br>
**==> picture [330 x 132] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|Type|Qty.|Order No.|
|or|6|mm terminal width (e.g. SAK 2.5)|DQS 2 (2pole)|20|0471560000|
|with jumper/as test plug|for up to 20 A|
|with diode 1 N 4007|DQS 2 (2pole)|20|0471460000|
|max. 1 A|
|without diode|DQS 2 (2pole)|20|0471660000|
|installation space 9 x 9 x 4.5|
|for|6.5|mm terminal width|QS 2 (2pole)|20|0212700000|
|(e.g. SAK 4)|for up to 20 A|
|for|8|mm terminal width|
|(e.g SAK 6 N)|
|for|10|mm terminal width|
|(e.g SAK 10)|
|for|12|mm terminal width|
|(e.g SAK 16)|
**----- End of picture text -----**<br>
**Qty. Order No.**
**Type**
**==> picture [154 x 51] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|QS 2 (2pole)|20|0270960000|
|dim. x = 8 mm,|y = 16 mm|
|QS 2 (2pole)|20|0270860000|
|dim. x = 10 mm,|y = 20 mm|
|QS 2 (2pole)|20|0270760000|
|dim. x = 12 mm,|y = 20 mm|
**----- End of picture text -----**<br>
**I.13**
**Testing/Checking**
## **Test plugs/Sockets**
## **PS**
**==> picture [102 x 40] intentionally omitted <==**
**----- Start of picture text -----**<br>
Test plug<br>Insulation<br>available in<br>various colours<br>Socket<br>**----- End of picture text -----**<br>
**Test plugs (PS)** are used for measurement purposes or for the final checking of a finished terminal strip installation. Test plugs for sockets are available with 2.3 and 4 mm I.D.
The difference between these and a test adapter is that the test plug does not automatically clip into the terminal. This means that a secure connection to modular feedthrough terminals up to 35 mm[2] is only possible in conjunction with a socket.
## **PS 2 / PS 2 MC**
The **sockets (StB)** enable the PS test plug and the QS plugin crossconnectors to be plugged in. The sockets are screwed into the busbar in the crossconnection slot in the middle of the terminal or screwed into the modular terminal instead of the clamping screw.
If a crossconnection has to provide a test option as well, then an StB 28.5 or 30.5, which has an insulating sleeve and can accommodate the PS 4 test plug, is screwed in instead of the fixing screw.
**==> picture [331 x 69] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type Qty. Order No. Type Qty. Order No.<br>2.3 mm dia./rated current 17.5 A PS 2 for 2 mm dia. sockets 20 0293800000<br>PS 2.3 20 0180400000 for soldered conductor crosssection 1.5 mm [2]<br>4.0 mm dia./rated current 24 A PS 2 MC 20 0310000000<br>PS 4 20 0299600000 for soldered conductor crosssection<br>0.75 mm [2] , can also be plugged directly into<br>threaded hole in busbar for terminal types<br>AKZ 4, AKB 4, AKZ 2.5, AKZ 1.5<br>**----- End of picture text -----**<br>
**I**
## **ZS 2.3/4**
## **FZS 2/4 / FK 4**
## **TA 1**
**==> picture [121 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
FK 4<br>FZS 2/4<br>**----- End of picture text -----**<br>
|**Type**<br>**Qty.**<br>**Order No.**<br>ZS 2.3/4<br>20<br>**0249600000**<br>Adapter plug for connecting sockets with<br>2.3and 4 mm I.D. Can also be plugged||**Type**<br>**Qty.**<br>**Order No.**<br>FZS 2/4<br>20<br>**1276300000**<br>Flexible adapter plug for connecting<br>sockets with 2.3 and 4 mm I.D.||**Type**<br>**Qty.**<br>**Order No.**<br>TA 1<br>20<br>**0535860000**<br>The conductor is soldered on, or crimped<br>on with the HTG 58 crimping pliers.|
|---|---|---|---|---|
|directlyinto threaded hole in busbar for<br>terminal types SAK 2.5 and SAK 4.||FK 4<br>20<br>**1678650000**<br>Flexible coupling for connecting test||HTG 58<br>1<br>**9012000000**<br>conductor: max. 0.75 mm2|
|||plug to test adapter. The unconnected end<br>of the conductor is protected against||remove shoulder<br>strippinglength: 14 mm|
|||frayingbyawire end ferrule.|||
**I.14**
**Testing/Checking**
## **StB 5.5…17**
The SAKR modular disconnect terminals are available already fitted with sockets (see “Modular disconnect terminals”). These sockets are provided with a slot for actuating with a screw driver. Weidmüller can supply special screwdrivers with a shoulder for this purpose (chapter J).
**==> picture [44 x 143] intentionally omitted <==**
**----- Start of picture text -----**<br>
PS 4<br>BS M 3 x 20<br>STB 30.5<br>STB 25<br>| | VH 12QL<br>STB 14<br>AT<br>lal<br>BS 25<br>STB 35<br>BS 25<br>QVS<br>i<br>VH 19<br>**----- End of picture text -----**<br>
||**Type**<br>**for terminal type**<br>**L1**<br>**L2**<br>**d1**<br>**d2**<br>**M**<br>**Qty.**<br>**Order No.**<br>StB 5.5<br>SAKL 4/20 1)<br>5,5<br>11<br>2.3<br>3.7<br>3<br>100<br>**0122700000**|
|---|---|
||StB 6<br>AKZ 4,DK 4,SAKR 1)<br>6<br>11.5<br>2.3<br>3.9<br>3<br>100<br>**0379400000**|
||StB 6<br>SAK 2.5 1)<br>6<br>13<br>2.3<br>3.9<br>2.5<br>50<br>**0130200000**|
||StB 7<br>SAKC4,SAK4 1)<br>7<br>14.5<br>2.3<br>4<br>3<br>100<br>**0358500000**|
||StB 7.5<br>SAK 10,SAKB 10 1)<br>7.5<br>17<br>4<br>6<br>4<br>50<br>**0130000000**|
||StB 8.5<br>AKZ 4 / DK 4/ SAKD 2.5 N<br>8.5<br>11.5<br>2.3<br>4<br>2.5<br>50<br>**0215700000**<br>StB 8.5<br>SAK 2.5<br>8.5<br>12<br>2.3<br>5<br>3<br>50<br>**0280600000**<br>StB 8.5<br>SAKT 4<br>8.5<br>12<br>2<br>4.5<br>3<br>50<br>**0244600000**<br>StB 13.5<br>SAKA 10 / SAKC 10<br>13.5<br>18.5<br>4<br>6<br>4<br>50<br>**0135200000**<br>StB 14<br>SAK 4<br>14<br>17.5<br>2.3<br>5<br>3<br>50<br>**0168600000**<br>~~ee~~<br>=~~8=— |~~<br>~~ee~~<br>~~ltt~~<br>~~ee~~<br>~~— |~~|
|StB 14<br>SAK6N,10,16 / SAKT 1,SAKT 2<br>14<br>19<br>4<br>6<br>3<br>50<br>**0169900000**<br>StB 16<br>SAK70,SAK 95<br>16<br>28<br>4<br>7<br>5<br>50<br>**0385400000**<br>StB 16<br>SAK 35,SAKB 10<br>16<br>23<br>4<br>7<br>4<br>50<br>**0140200000**<br>~~oO~~<br>~~osé4™NoNuNtttN~~||
||StB 17<br>SAKC 10<br>17<br>22<br>4<br>6<br>4<br>50<br>**0147100000**|
## **StB 28.5 / 30.5**
## ~~a~~
## **StB for SAKT**
The type StB 25 socket accepts test plug PS 4 in type SAKT 1 and SAKT 2 disconnect terminals, or the QS plugin cross connector.
The type StB 35 socket is used when simultaneous testing is necessary with a QVS crossconnection slider.
Complete with insulating sleeve to prevent contact with live parts and colourcoded test plug and plugin crossconnection, 4 mm dia.
||Jl|
|---|---|
||**Type**<br>**Colour terminal type**<br>**L1**<br>**L2**<br>**L Qty. Order No.**<br>StB 30.5 black<br>SAK 4,SAK 6 N 30.5 31.7 7<br>50 **0341000000**|
||StB 30.5 grey<br>SAK 10,SAK 16<br>–<br>–<br>–<br>50 **0341100000**|
||StB 30.5 blue<br>–<br>–<br>–<br>50 **0341200000**|
||StB 30.5 red<br>–<br>–<br>–<br>50 **0341300000**|
||StB 30.5 green<br>–<br>–<br>–<br>50 **0341400000**|
|StB 30.5 yellow<br>–<br>–<br>–<br>50 **0341500000**<br>StB 30.5 violet<br>–<br>–<br>–<br>50 **0341600000**<br>~~_~~<br>~~eR~~<br>~~Ts~~<br>~~i~~ # i ~~'|~~||
||StB 28.5 black<br>SAK 2.5<br>28.5 29.7 9<br>50 **0133400000**|
## **StB 25**
## **StB 35**
**I**
|**Type**<br>**Colour**<br>**for terminal type**<br>**Qty.**<br>**Order No.**<br>StB 25 yellow<br>SAKT 1 and SAKT 2<br>50<br>**0267200000**||**Type**<br>**Colour**<br>**for terminal type**<br>**Qty.**<br>**Order No.**<br>StB 35 yellow<br>SAKT 1 and SAKT 2<br>50<br>**0389000000**|
|---|---|---|
|green<br>50<br>**0271200000**||green<br>50<br>**0388900000**|
|violet<br>50<br>**0271300000**||violet<br>50<br>**0389100000**|
|black<br>50<br>**0271500000**||black<br>50<br>**0388500000**|
|grey<br>50<br>**0271400000**||grey<br>50<br>**0388600000**|
|blue<br>50<br>**0343400000**||blue<br>50<br>**0388700000**|
|red<br>50<br>**0343300000**||red<br>50<br>**0388800000**|
1) used instead of the clamping screw
**I.15**
**Protective covers**
## **Protective covers**
Several safety regulations, e.g. the German accident prevention code covering electrical systems and equipment (VBG 4) or the standard VDE 0106 part 100 (March 1983), call for live parts of electrical systems to be protected against direct contact by any part of the body.
In the case of modular terminals this protection must always be provided in the form of additional covers when crossconnectors or test sockets are fitted. Therefore, Weidmüller can supply cover strips with associated retaining plates which can be used with the more common sizes of terminal. The retaining plates can be fitted at the ends or within the terminal strip, and can be fitted to TS 32, TS 35 or TS 15 terminal rails.
Spacing of retaining plates:
The length of the ADP 1, 2 and 3 between retaining plates should not exceed about 500 mm. The cover strip is clipped into tabs on the side. Additional security is provided by a spigot on the retaining plate, which can also be sealed with lead. On terminal type SAK 95 the ADP 3 cover strip can be clipped directly onto the terminal. Transparent cover strips enable the terminals with their accessories and labelling to remain visible at all times. Additional labelling, e.g. for groups, can be added.
## **ADP**
## **HP**
|Cover strips<br>Unplasticised PVC,<br>supplied in 1 m pieces,<br>max. temperature<br>70°C|Cover strips<br>Unplasticised PVC,<br>supplied in 1 m pieces,<br>max. temperature<br>70°C|Retaining plates<br>PA 66, 2 mm thick|Retaining plates<br>PA 66, 2 mm thick|Ne|
|---|---|---|---|---|
|||||**For fitting to TS 35 and**|
|||||**TS 32,**with spigot for lead seal|
||**transparent**||Spigot for lead seal||
|**Type**<br>**Order No.**<br>ADP 1<br>**0485200000**<br>ADP 2<br>**0485300000**<br>U<br>~~—_~~<br>~~ee~~<br>1<br>~~——~~<br>-}— 48 —+<br>~~SSS~~<br>f—\~~TO~~<br>!~~4~~<br>i<br>~~———~~<br>-}—615+<br>~~—~~<br>T||||**Type**<br>**Order No.**<br>HP 1<br>**0485560000**<br>HP 2<br>**0485660000**<br>~~—_~~<br>~~ee~~<br>~~__~~<br>~~=~~<br>~~**—**—_ ae~~|
|||ADP 3<br>**0485400000**<br>~~Too~~<br>3 ~~——_——~~<br>~~——~~<br>~~=~~|||pr|HP 3<br>**0485760000**<br>~~—_—~~<br>~~|~~<br>~~__~~<br>~~=~~|
||||||
||grey||||
|7,64|**Type**<br>**Order No.**<br>ADP 4<br>**1430760000**<br>(1000 mm)<br>ADP 4<br>**1378160000**|g<br>|||~~———~~<br>~~ee~~|
||(300 mm)||||
|||||HP 4<br>**0485860000**|
||TSK 31.5<br>**0347960000**||||
## **I**
|**Overall dimensions**<br>for mountingon terminal rail<br>ADP 1,HP 1<br>ADP 2,HP 2|**A**<br>**A**<br>TS 32<br>TS 35 x 7.5<br>61<br>56<br>77<br>72|**A**<br>**A**<br>**B**<br>TS 35 x 15<br>TS 15<br>63<br>49<br>79<br>62.5|**C**<br>6<br>6|
|---|---|---|---|
|ADP 3,HP 3<br>ADP 3,HP 4<br>ADP 1,HP 8<br>TSK 31.5, HP 7<br>**Labelling material**|94<br>89<br>73.5<br>68.5|86<br>92<br>75.5<br>92<br>45<br>49<br>35<br>31<br>**Qty.**|6<br>6<br>6<br>6<br>**Order No.**|
|“Lightningflash” symbol,selfadhesive,20 labels|20 labelsper card|5|**0566700000**|
|**For fitting to TS 15**<br>**Type**<br>**Order No.**|
|---|
|HP 7<br>**0258260000**|
|~~—~~<br>~~.~~<br>~~ele~~|
|HP 8<br>**0258360000**<br>~~—~~|
* only for PA 66 versions
|**Allocation to some terminal types**<br>SAKD 2.5 N,EK 2.5 N,SAK 2.5,SAK 2.5/35||**Type**<br>ADP 1|**ADP cover strips**|**ADP cover strips**|**Qty.**<br>36|**Order No.**<br>**0485200000**||**HP retaining plates**<br>**Type**<br>**Qty.**<br>**Order No.**<br>HP 1<br>20<br>**0485560000**|
|---|---|---|---|---|---|---|---|---|
|SAK 4,EK 4,SAK 4/35,EK 2.5/35,EK 4/35||ADP 2|||36|**0485300000**||HP 2<br>20<br>**0485660000**|
|SAK 6 N,EK 10,SAK 10,EK 6/35,SAK 6/35,EK 10/35|||||||||
|SAKR,SAKRD,DK 4|||||||||
|SAK 16,EK 16,EK 35,SAK 35,SAKC 4,SAK 16/35||ADP 3|||20|**0485400000**||HP 3<br>20<br>**0485760000**|
|SAKC 10,SAK 70,SAKS 1,SAKS 2,Sak 35/35,SAK 70/35|||||||||
|SAKS 3,SAKS 4,SAKS 5|||||||||
||||||||||
|SAK 95||ADP 3|||1|**0485400000**||not applicable|
|ASK 1,SAKA 10,SAKT 1,SAKB 10,SAKT 2,||ADP 3|||1|**0485400000**||HP 4<br>20<br>**0485860000**|
|AST*,SAK 2.5,SAK 4||ADP 4|||1|**1430760000**||not applicable|
|||ADP 1|||1|**0485200000**||HP 8<br>20<br>**0258360000**|
|1000 mm long|||||1|**1430760000**||not applicable|
|300 mm long||ADP 4|||10|**1378160000**|||
|||TSK 31.5|||1|**0347960000**||HP 7<br>20<br>**0258260000**|
**I.16**
**Protective covers**
Several German VDE standards, e.g. VDE 0106 part 100 (March 1983), specify that mains terminals must be covered. Weidmüller can supply a range of such covers printed with a warning “lightning flash” and the international warning symbol. The other side features a “lightning flash” symbol with the warning “Danger! Electricity”. Plastic screws are used to fix the cover plates to the terminal strips. The cover plates are intended for 3 or 4pole terminals. Type BSK plastic screws are used to fix the plates. BSK = PA 66
## **AD/WAD covers**
**==> picture [328 x 203] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|AD 3 (3-pole)|
|Terminal type|Terminal width (mm)|Qty.|Order No.|Screw|Qty.|Order No.|
|SAK 2.5|6|50|0297900000|M 3 x 22|100|0128900000|
|AKZ 4|6|50|0297900000|M 2.5 x 18|100|0303300000|
|DK 4 Q|6|50|0297900000|M 2.5 x 18|100|0303300000|
|SAK 4|6.5|50|0297600000|M 3 x 22|100|0128900000|
|SAK 6 N|8|50|0297700000|M 3 x 22|100|0128900000|
|SAK 10|10|50|0178500000|M 3 x 22|100|0128900000|
|SAK 16|12|50|0297800000|M 3 x 22|100|0128900000|
|SAK 35 N|18|50|0273400000|M 4 x 32|100|0129100000|
|SAK 70|22|10|0344300000|M 5 x 45|50|0344400000|
|Screw for lead seal|M 3 x 20|100|0451300000|
|AD 3 (4-pole)|
|SAK 2.5|6|50|0303400000|M 3 x 22|100|0128900000|
|AKZ 4|6|50|0303400000|M 2.5 x 18|100|0303300000|
|DK 4 Q|6|50|0303400000|M 2.5 x 18|100|0303300000|
|SAK 4|6.5|50|0285300000|M 3 x 22|100|0128900000|
|SAK 6 N|8|50|0196600000|M 3 x 22|100|0128900000|
|SAK 10|10|50|0178600000|M 3 x 22|100|0128900000|
|SAK 16|12|50|0518200000|M 3 x 22|100|0128900000|
|SAK 35|18|50|0178700000|M 4 x 32|100|0129100000|
|SAK 35 N|16|50|0576700000|M 4 x 32|100|0129100000|
|Screw for lead seal|M 3 x 20|100|0451300000|
**----- End of picture text -----**<br>
**I**
## **TBS 2 / BST 2**
for the SAK series
## **Protective covers**
## **Details**
- For covering uninsulated cross-connections on SAK 2.5...SAK 16 terminals.
- Identification of functional groups.
- Easily fitted by inserting the insulating plate into the existing insulating plate slot in the terminal.
## **AD**
for SAKG
## **Cover plates**
These can be assembled either with two end clamp plates or with one end clamp plate and one partition plate plus mounting bracket.
## **Cover plates with self-adhesive label**
**==> picture [79 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions of cover plates<br>**----- End of picture text -----**<br>
## **AH**
for SAKG
## **Shrouding covers**
For opentype terminals like type SAKG. Shrouding covers are used – instead of other cover types – to provide the necessary protection against contact (required by German standard VBG 4). Shrouding covers are simply placed over the terminals.
- Labelling strips are clipped into the insulating plates.
- Labelling of stable labelling strip with felt-tip pen for permanent labelling or pencil for temporary labelling.
2 mm thick
**==> picture [328 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Type|Order No.|Type|a|b|c|Order No.|
|Type|for SAKG 28|AD 3|89|120|74|–|
|TBS 2,|polyamide|for SAKG 28|AD 4|116|120|102|0263100000|
|BST 2, unplasticised PVC|for SAKG 32 and 70|AD 4|132|120|118|0283100000|
|Ordering data|for SAKG 40|AD 3|124|160|110|–|
|Type|for SAKG 40|AD 4|164|160|150|0263200000|
|TBS insulating|plate|1287860000|for SAKG 46|AD 4|188|160|174|0263300000|
|BST 2 labelling strip|(300 mm long)|1287700000|for SAKG 54|AD 3|166|160|152|0264900000|
|for SAKG 54|AD 4|220|160|206|0261100000|
**----- End of picture text -----**<br>
**==> picture [154 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|yw|||
|Type|a|a|b|c|d|Order No.|i|
|dimensions in mm|
|for SAKG 28|AH 28|156|26|74|94|0326660000|
|for SAKG 32/70|AH 32|156|30|74|94|0326760000|
|for SAKG 40|AH 40|186|38|78|94|0326860000|
|for SAKG 46|AH 46|196|46|78|94|0326960000|
**----- End of picture text -----**<br>
**I.17**
**Protective covers**
## **Cover strips for terminal strips**
To protect against contact, dust and moisture, Weidmüller can supply cover strips which, for example, are useful in signal or lighting mast distribution boards.
Weidmüller can supply fully assembled and labelled terminal strips to meet your specification.
## **ADL**
## **AD 250**
|**ADL**|**ADL**|**AD 250**|**AD 250**|**AD 250**|
|---|---|---|---|---|
|The ADL cover can be<br>clipped to a TS 32 terminal<br>rail.<br>**A selection of terminal types that can be fitted below**<br>**this cover strip:**<br>i)<br>64<br>| sal=i <br>|<br>|<br>|<br>eS<br>|<br>139<br>|<br>J||**HP**<br>retaining plate<br>suitable for TS 32 and<br>TS 35 x 7.5<br>height for TS 32: 64.5 mm<br>height for TS 35 x 7.5: 63 mm<br>**A selection of terminal types that can be fitted below**<br>**this cover strip:**<br>oop<br> 7<br>3<br>Np|||
|**TS 32**||**TS 32**||**TS 35**|
|SAKD 2.5 N ... SAK 10||SAKD 2.5 N ... SAK 10||WDU 2.5 to WDU 10|
|EK 2.5 N ... EK 10||EK 2.5 ... EK 10||WPE 2.5 to WPE 10|
|SAKR,ASK 1,SAKT 1,SAKT 4,SAKB 10||SAKR,ASK 1,SAKT 1,SAKB 10||WNT 2.5 to WNT 10|
|SAKS 1,SAKS 3||SAKS 1,SAKS 3||ASK 1,|
|||||SAKS 1/35,SAKS 3/35|
|**Type**<br>ADL|**Qty.**<br>**Order No.**<br>2<br>**0210800000**|**Type**<br>AD 250 L = 250 mm||**Qty.**<br>**Order No.**<br>1<br>**0634100000**|
||||||
|||HP EK1 32/2 AD 250||1<br>**0634300000**|
## **I**
**I.18**
**I**
**I.19**
**Accessories for modular disconnect test terminals**
## **QVS... cross-connection sliders**
VH 19 connecting sleeves and BS 25 fixing screws (or StB 35 sockets) are required for fixing the QVS crossconnections to the individual terminals.
The fixing screws include an insulating sleeve for colour coding purposes and a guide for the screwdriver. The crossconnection sliders are designed so that the test plug sockets in the terminals remain accessible in every position.
The type QVS 2S 2pole version is designed so that it can be slid even when a test plug has been inserted. If a test option is required when a QVS has been fitted, the fixing is best achieved with the StB 35 socket.
The clearance and creepage values required for the rated voltage of the terminal change when accessories are fitted.
StB sockets are screwed into the busbar for the modular terminals. They are used to accommodate PS 4 test plugs or QS 2 plugin crossconnectors.
**I**
**==> picture [171 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
QVSK 2 (167036) QVS 2 (030730)<br>: p<br>SAKT 2, SAKT 1 SAKT 1<br>**----- End of picture text -----**<br>
Note: QVS 2 units cannot be switched when installed like this.
## **STB**
## **STB**
## **Rated voltages**
|**Rated voltages**|||**STB**|**STB**|**STB**||**STB**|**STB**|||
|---|---|---|---|---|---|---|---|---|---|---|
|for adjacent<br>rated voltage<br>QVS<br>63 V<br>QL<br>250 V<br>~~Oo~~||for adjacent<br>rated voltage<br>StB 25<br>63 V<br>StB 35<br>63 V|Crossconnection sliders<br>QVS<br>QVS<br>QVSK 2<br>HeeS|||QVS 2S<br>eS|Sockets<br>;<br> i:<br>@<br>@<br>@|||| ||
|TW partition plates or TSch insulating plates<br>must be used to maintain the rated voltage.<br>The**SSP 3**and**SSP 4**prevent the un||**Type**<br>**Qty.**<br>**Order No.**<br>SSP 3<br>100<br>**0531760000**|**Type**<br>QVS 2|**No. of**<br>**poles**<br>2poles|**Qty.**<br>**Order No.**<br>20<br>**0307300000**|||**Type**<br>**Colour**<br>**STB 14**<br>STB 14|**Qty.**<br>50|**Order No.**<br>**0169900000**|
|intended making or breaking of circuits. They<br>lock the disconnection slider in its respective<br>position. The lockout device can be easily<br>pressed from above into the terminal and is<br>then only removable with a tool.||SSP 4<br>20<br>**1319360000**|QVSK 2<br>QVS 3<br>QVS 4<br>QVS 2S|2poles<br>3poles<br>4poles<br>2poles|20<br>**1670360000**<br>20<br>**0329300000**<br>20<br>**0307400000**<br>20<br>**0358460000**|||**STB 25**<br>STB 25<br>yellow<br>STB 25<br>green<br>STB 25<br>violet|50<br>50<br>50|**0267200000**<br>**0271200000**<br>**0271300000**|
|||||||||STB 25<br>black|50|**0271500000**|
|||||||||STB 25<br>grey|50|**0271400000**|
|||||||||STB 25<br>blue|50|**0343400000**|
|||||||||STB 25<br>red<br>**STB 30,5**<br>STB 30.5<br>yellow|50<br>50|**0343300000**<br>**0341500000**|
|||||||||STB 30.5<br>green|50|**0341400000**|
|||||||||STB 30.5<br>violet|50|**0341600000**|
|||||||||STB 30.5<br>black|50|**0341000000**|
|||||||||STB 30.5<br>grey|50|**0341100000**|
|||||||||STB 30.5<br>blue|50|**0341200000**|
|||||||||STB 30.5<br>red<br>**STB 35**<br>STB 35<br>yellow|50<br>50|**0341300000**<br>**0389000000**|
|||||||||STB 35<br>green|50|**0388900000**|
|||||||||STB 35<br>violet|50|**0389100000**|
|||||||||STB 35<br>black|50|**0388500000**|
|||||||||STB 35<br>grey|50|**0388600000**|
|||||||||STB 35<br>blue|50|**0388700000**|
|||||||||STB 35<br>red|50|**0388800000**|
**I.20**
**Accessories for modular disconnect test terminals**
## **BS fixing screws**
## **VH connecting sleeves**
## **QL cross-connections**
The QL crossconnections enable connections between adjacent modular terminals.
## **QL cross-connection links**
## **QB cross-connection comb**
The QB can be inserted from above on the SAKT1/QT1 crossconnect/ disconnect terminal. The connection or disconnection is then achieved by means of the integral disconnection slider.
## **QS 2 plug-in crossconnection**
For 4 mm dia. sockets, for up to 44 A.
QL crossconnection links are used as permanent, i.e. non switchable, crossconnections on SAKT disconnect terminals. VH 12 connecting sleeves and BS M3 x 20 fixing screws (or StB 30.5 sockets) are required for fixing these in position. The clearance and creepage values required for the rated voltage of the terminal can change when accessories are fitted. This is especially true with crossconnections between neighbouring terminals with different potentials.
## **BS / VH**
**==> picture [106 x 13] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fixing screw Connecting<br>sleeve<br>**----- End of picture text -----**<br>
## **QL / Q**
## **QB**
## **QS 2**
**I**
|Fixing screw|Fixing screw<br>°<br>Is|Connecting<br>sleeve||e@ @|e@ @|ie)|oy|||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||Is|||QL 2, QL 3, QL 4<br>Crossconnection link|||Q 3|||||||||||
|||||(BS and VH<br>also required)|||Preassembled<br>crossconnection||QB 2, QB 3, QB 4,|QB 2, QB 3, QB 4,|QB 2, QB 3, QB 4,|||iz.|||
|**Type**<br>**Colour**<br>**Fixing screws**<br>BS 25<br>yellow||**Qty.**<br>**Order No.**<br>50<br>**0335700000**||**Type**<br>QL 2|**No. of**<br>**poles**<br>2poles|**Qty.**<br>50|**Order No.**<br>**0194300000**||**Type**<br>QB 2|**No. of**<br>**poles**<br>2poles|**Qty.**<br>**Order No.**<br>50<br>**0205700000**||**Type**<br>**WQV**<br>QS 2|**No. of**<br>**poles**<br>2 poles|**Qty.**<br>20|**Order No.**<br>**0270960000**|
|BS 25|green|50<br>**0335600000**||QL 3|3poles|50|**0194400000**||QB 3|3poles|50<br>**0205800000**||x = 8 mm,|y= 16 mm|||
|BS 25|violet|50<br>**0335800000**||QL 4|4poles|50|**0194500000**||QB 4|4poles|50<br>**0205900000**||QS 2|2 poles|20|**0270860000**|
|BS 25|black|50<br>**0335200000**||QL 5|5poles|50|**0220500000**||QB 10|10poles|20<br>**0343800000**||x = 10 mm, y= 20 mm||||
|BS 25|grey|50<br>**0335300000**||QL 6|6poles|50|**0220600000**||||||QS 2|2 poles|20|**0270760000**|
|BS 25|blue|50<br>**0335400000**||QL 10|10poles|20|**0338300000**||||||x = 12 mm, y= 20 mm||||
|BS 25|red|50<br>**0335500000**||QL 15|15 poles|10|**0221200000**||||||||||
|BS 25|uninsulated 50<br>**0334700000**|||ECu 57|||||||||||||
|BS M 3 x 20||100<br>**0377100000**||(copper alloy)|||||||||||||
|CuNi 60|||||||||||||||||
|(copper alloy)||||Q2|2poles|50|**0456700000**||||||||||
|||||Q3|3poles|50|**0456800000**||||||||||
|**Connecting sleeves**||||Q4|4poles|50|**0456900000**||||||||||
|VH 12||100<br>**0249000000**||Q10|10poles|20|**0457000000**||||||||||
|ECu 57<br>(copper alloy)|||||||||||||||||
|VH 19<br>CuZn 39<br>(brass alloy)||50<br>**0318000000**|||||||||||||||
**I.21**
**I**
**I.22**
**Contents**
## Tools and ferrules
## **Tools and ferrules**
|**Tools and ferrules**||
|---|---|
|Cutting, stripping and crimping tools|J.2|
|Rechargeable and electric torque screwdriver|J.10|
|Screwdrivers|J.12|
|Wire end ferrules / Insulated cable lugs|J.21|
|Wire end ferrules with plastic collar|J.22|
|Twin-wire end ferrules with plastic collar|J.28|
|Wire end ferrules for short-circuit and earth-fault-proof cables|J.31|
|Wire end ferrules with plastic collar, spezial sizes|J.32|
|Wire end ferrules without plastik collar|J.33|
|Tools for insulated cable lugs and ferrules|J.35|
**J**
**J.1**
**Tools**
## **J**
## **Cutter**
- Cutting formation for different cable sizes increases the quality of the cuts for smaller cross-sections.
## **Technical data**
|**Max. cutting performance copper cable**||
|---|---|
|Solid (max. conductor cross-section)|mm2/ AWG|
|Stranded (max. conductor cross-section)|mm2/ AWG|
|Flexible (max. conductor cross-section)|mm2/ AWG|
|Flexible, Stranded (max. diameter)|mm|
|Sector line||
|**Max. cutting performance aluminium cable**<br>Stranded (max. conductor cross-section)<br>Stranded (max. diameter)<br>Solid<br>**Data-/ telephone-/ control cable**<br>O.D. max.<br>**Tool data**<br>Length / width / height<br>Weight<br>**Information**|mm2/ AWG<br>mm<br>mm2<br>mm<br>mm<br>g|
|**Ordering data**||
|**Version**||
## **Ordering data**
**Information**
## **Accessories**
## **KT 8**
## **KT 12**
## **Notching tool**
## **Notching tool**
Cutting tool that does not damage the conductor; for cutting copper and aluminium cables with a diameter of up to 8 mm.
Cutting tool that does not damage the conductor; for cutting copper and aluminium cables with a diameter of up to 12 mm.
- Not suitable for steel wires, steel-armoured cables, aluminium alloys and hard-drawn copper conductors!
- Not suitable for steel wires, steel-armoured cables, aluminium alloys and hard-drawn copper conductors!
|**KT8**||**KT12**|
|---|---|---|
|16 / 6||16 / 6|
|16 / 6||25 / 3|
|16 / 6||35 / 2|
|8||12|
|16 / 6||25 / 6|
|8||8|
|16<br>8<br>165 / 65 / 25||25<br>12<br>215 / 66 / 28|
|180<br>Tool closed||300<br>Tool closed|
||||
|**Type**<br>**Qty.**<br>**Order No.**<br>KT 8<br>1<br>**9002650000**||**Type**<br>**Qty.**<br>**Order No.**<br>KT 12<br>1<br>**9002660000**|
||||
||||
|**Type**<br>**Qty.**<br>**Order No.**||**Type**<br>**Qty.**<br>**Order No.**|
**Information**
**J.2**
**Tools**
## **WAW 1**
## **WAW 2**
## **Notching tool**
## **Notching tool**
Tool for trimming poles from WQV 2.5 to WQV 35 cross connections used in Weidmueller W-Series terminals.
Tool for punching out the cross-connection windows of the Weidmüller W-Series, Test-disconnect terminal WTR 2.5, Fuse terminal WSI 6.
## **Technical data**
## **Technical data**
**==> picture [156 x 16] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Length|167 mm|
|Weight|227 g|
**----- End of picture text -----**<br>
**==> picture [156 x 16] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Length|205 mm|
|Weight|338 g|
**----- End of picture text -----**<br>
## **Ordering data**
## **Ordering data**
**==> picture [328 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|Type|Qty.|Order No.|Type|Qty.|Order No.|
|WAW 1|1|9004500000|WAW 2|1|9004510000|
**----- End of picture text -----**<br>
## **KT ZQV**
**Cutter**
Cutter for non-pinch cutting of Weidmüller Z-series cross-connections.
## **Technical data**
**==> picture [156 x 16] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Length|215 mm|
|Weight|300 g|
**----- End of picture text -----**<br>
## **Ordering data**
**==> picture [154 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|KT ZQV|1|9002170000|
**----- End of picture text -----**<br>
**J**
**J.3**
**Tools**
## **Stripping and cutting tools**
## **stripax[®]**
## **stripax[®] 16**
- For flexible and massive conductors with PVCinsulation
- Stripping length adjustable with shoulder
- automatic opening of the clamping jaws after stripping
- no splicing of the single conductor
- adjustable to different insulation thicknesses
- cable with double insulation in two processing steps without special adjustment
- Blade-device free from float and self-adjustable
- long durability
- optimised ergonomically design
## **J**
## **Technical data**
**==> picture [160 x 177] intentionally omitted <==**
**----- Start of picture text -----**<br>
Max. stripping performance<br>Cable model<br>Conductor cross-section mm [2]<br>Conductor diameter mm<br>Max. stripping length mm<br>Adjustable depth of cut mm<br>Cutting performance<br>Max. cutting performance mm [2]<br>Tool data<br>Length mm<br>Weight g<br>Information<br>Ordering data<br>Version<br>**----- End of picture text -----**<br>
**==> picture [36 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
Information<br>Information<br>**----- End of picture text -----**<br>
## **Accessories**
Stripping and cutting tool for flexible conductors with PVC-insulation
Stripping and cutting tool for flexible and massive conductors with PVC-insulation
of 0.08...6 mm[2] (~AWG 28...10)
- of 6...16 mm[2] (~AWG 10... 6)
- Cutting of flexible and massive conductors up to 6 mm[2] (AWG 10)
- No damaging of the conductor due to special, self-adjustable stripping blades
- Processing of multi-conductors, with thin flat ribbon cables even multiple conductors in one operation
- No damaging of the conductor due to special blade forms
|**stripax®**||**stripax® 16**|
|---|---|---|
|flexible & solid conductors with PVC insulation||flexible & solid conductors with PVC insulation|
|0.08 … 6||6 … 16|
||||
|20||20|
|6||6|
|190||190|
|155||155|
||||
|**Type**<br>**Qty.**<br>**Order No.**<br>STRIPAX<br>1<br>**9005000000**||**Type**<br>**Qty.**<br>**Order No.**<br>STRIPAX 16<br>1<br>**9005610000**|
||||
||||
|**Type**<br>**Qty.**<br>**Order No.**<br>Cleaningbrush<br>5<br>**9005450000**||**Type**<br>**Qty.**<br>**Order No.**<br>Cleaningbrush<br>5<br>**9005450000**|
|Spare stripping blades<br>1<br>**9054030000**||Spare stripping blades<br>1<br>**9054080000**|
**J.4**
**Tools**
## **Crimping and cutting tool for wire end stripax[®] plus 2.5 ferrules**
**Cutting, stripping and crimping tool for wire end ferrules**
- Cutting
- Stripping
- Crimping
- Conductor entry sideways
- Wire end ferrules acoording to DIN 46228-4
- Ratchet for precise crimping
- Efficient operation: Change of tools not necessary, therefore significant saving of time
- automatic transport of wire end ferrules
- Only wire end ferrules in strips of 50 pieces may be used with this tool. The use of wire end ferrules on reels can lead to damage.
Cutting, stripping and crimping tool for linked wire end ferrules on strip with 0.5...2.5 mm[2]
(~AWG 20...14) from Weidmüller
- Easy handling of wire end ferrules
- Automatic feeding of wire end ferrules
**J**
## **Technical data**
|**Technical data**||
|---|---|
|**Description of contact**<br>Type of contact|**stripax® plus 2.5**<br>Stripof wire end ferrules|
|Crimping range<br>mm2|0.5 ... 2.5|
|Crimping range 1 (with multiple crimping positions)<br>mm2|0.5 ... 0.75|
|Crimping range 2 (with multiple crimping positions)<br>mm2|1 ... 1.5|
|Crimping range 3 (with multiple crimping positions)<br>mm2|2.5|
|Plug width<br>mm||
|**Tool data**<br>Length<br>mm||210|
|---|---|---|
|Weight<br>g<br>**Information**||260<br>Only Weidmüller wire end ferrules on strips à 50 pieces may be used.|
|**Ordering data**|||
|**Version**||**Type**<br> **Qty.**<br>**Order No.**<br>stripaxplus 2,5<br>1<br>**9020000000**|
||||
|**Information**||Spare cutter (order no.: 9050340000)|
|**Accessories**|||
|**Information**|||
## **Ordering data**
## **Accessories**
**J.5**
**Tools**
## **Crimping tools for wire end ferrules**
- Ratchet for precise crimping
- Release mechanism in case of incorrect operation
## **PZ 4**
**Crimping tool for wire end ferrules from 0.5...4 mm[2]**
## **PZ 6/5**
**Crimping tool for wire end ferrules from 0.25...6 mm[2]**
- Entry for wire end ferrule on the side
Crimping tool for wire end ferrules (to DIN 46228 part 1 and 4) with and without plastic collar and twin wire end ferrules of 0.5...2.5 mm[2]
- Only one crimping station for the whole crosssection
Crimping tool for wire end ferrules (to DIN 46228 pt. 1 and 4) with and without plastic collar of 0.25...6 mm[2] (~ AWG 24...10) and twin wire end ferrules of 0.5...4.0 mm[2]
- Crimp according to Euro-Norm EN 60947-1
- Five crimping stations corresponding to the conductor cross-section
- Approval according to VG 95211 (military designation VG 95 236 T 14 B 002)
**J**
## **Technical data**
**==> picture [160 x 159] intentionally omitted <==**
**----- Start of picture text -----**<br>
Description of contact<br>Type of contact<br>Crimping range mm [2]<br>Crimping range 1 (with multiple crimping positions) mm [2]<br>Crimping range 2 (with multiple crimping positions) mm [2]<br>Crimping range 3 (with multiple crimping positions) mm [2]<br>Crimping range 4 (with multiple crimping positions) mm [2]<br>Crimping range 5 (with multiple crimping positions) mm [2]<br>Tool data<br>Length mm<br>Weight g<br>Information<br>Ordering data<br>Version<br>**----- End of picture text -----**<br>
**==> picture [36 x 42] intentionally omitted <==**
**----- Start of picture text -----**<br>
Information<br>Information<br>**----- End of picture text -----**<br>
## **Accessories**
**PZ 4** Wire end ferrules with/without plastic collar 0.5 ... 4
**==> picture [154 x 68] intentionally omitted <==**
**----- Start of picture text -----**<br>
200<br>448<br>Type Qty. Order No.<br>PZ 4 1 9012500000<br>**----- End of picture text -----**<br>
## **PZ 6/5**
**==> picture [111 x 105] intentionally omitted <==**
**----- Start of picture text -----**<br>
Wire end ferrules with/without plastic collar<br>0.25 ... 6<br>0.25 ... 0.5<br>0.75 ... 1.5<br>2.5<br>4<br>6<br>200<br>423<br>**----- End of picture text -----**<br>
**==> picture [154 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type Qty. Order No.<br>PZ 6/5 1 9011460000<br>**----- End of picture text -----**<br>
**J.6**
**Tools**
**J**
## **Crimping tools for wire end ferrules**
- Ratchet for precise crimping
- Release mechanism in case of incorrect operation
## **PZ 3**
**Crimping tool for wire end ferrules from 0.5...6 mm[2]**
Crimping tool for wire end ferrules of 0.5...6 mm[2] with and without plastic collar according to DIN 46228 part 1 and 4 (~ AWG 20...10) and twin-wire end ferrules of 0.5...4 mm[2]
- Only one die for the whole cross-section
- Wire end ferrule insertion from the front
## **PZ 6 roto**
**Crimping tool for wire end ferrules from 0.14...6 mm[2]**
Crimping tool for wire end ferrules of 0.14...6 mm[2] with and without plastic collar to DIN 46228 part 1 and 4 (~ AWG 26...10) and twin-wire end ferrules of 0,5...4 mm[2]
- Only one die for the whole cross-section
- Pivoted die for wire end ferrule-insertion
- Wire end ferrule insertion from the front or from the side
## **Technical data**
**==> picture [157 x 61] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Description of contact|
|Type of contact|
|Crimping range|mm|[2]|
|Crimping range 1 (with multiple crimping positions)|mm|[2]|
|Crimping range 2 (with multiple crimping positions)|mm|[2]|
|Crimping range 3 (with multiple crimping positions)|mm|[2]|
|Plug width|mm|
**----- End of picture text -----**<br>
**PZ 3** Wire end ferrules with/without plastic collar 0.5 ... 6
## **PZ 6 roto**
Wire end ferrules with/without plastic collar 0.14 ... 6
## **Tool data**
**==> picture [160 x 60] intentionally omitted <==**
**----- Start of picture text -----**<br>
Length mm<br>Weight g<br>Information<br>Ordering data<br>Version<br>**----- End of picture text -----**<br>
**==> picture [154 x 68] intentionally omitted <==**
**----- Start of picture text -----**<br>
200<br>426<br>Type Qty. Order No.<br>PZ 3 1 0567300000<br>**----- End of picture text -----**<br>
**==> picture [154 x 68] intentionally omitted <==**
**----- Start of picture text -----**<br>
200<br>428<br>Type Qty. Order No.<br>PZ 6 roto 1 9014350000<br>**----- End of picture text -----**<br>
## **Information**
## **Accessories**
**Information**
**J.7**
**Tools**
## **Crimping tools for wire end ferrules**
- Ratchet for precise crimping
- Release mechanism in case of incorrect operation
## **PZ 16**
**Crimping tool for wire end ferrules from 6...16 mm[2]**
## **PZ ZH 16**
**Crimping tool for twin wire end ferrules, 6...16 mm[2]**
- Entry for wire end ferrule on the side
Crimping tool for wire end ferrules (to DIN 46228 part 1 and 4) with and without plastic collar from
- 6...16 mm[2] (~ AWG 10...6)
- Three crimping stations corresponding to the conductor cross-sections
Crimping tool for twin wire end ferrules (to DIN 46228 pt.4) with plastic collar from 6...16 mm[2]
- (~AWG 10...6)
- Three crimping stations corresponding to the conductor cross-sections
- Crimp according to Euro-Norm EN 60947-1
- Approval according to VG 95211 (military designation VG 95 236 T 14 B 002)
**J**
## **Technical data**
**Description of contact** Type of contact Crimping range mm[2] Crimping range 1 (with multiple crimping positions) mm[2] Crimping range 2 (with multiple crimping positions) mm[2] Crimping range 3 (with multiple crimping positions) mm[2] Plug width mm
**PZ 16** Wire end ferrules with/without plastic collar 6 ... 16 6 10 16
## **PZ ZH 16**
Twin wire end ferrules 6 ... 16 6 10 16
## **Tool data**
Length mm Weight g **Information Ordering datag data data Version**
## **Ordering datag data data**
|200||260|
|---|---|---|
|418||700|
||||
|**Type**<br> **Qty.**<br>**Order No.**<br>PZ 16<br>1<br>**9012600000**||**Type**<br> **Qty.**<br>**Order No.**<br>PZ ZH 16<br>1<br>**9013600000**|
## **Information**
## **Accessories**
**Information**
**J.8**
**Tools**
## **Crimping tools for wire end ferrules**
- Ratchet for precise crimping
- Release mechanism in case of incorrect operation
## **PZ 50**
**Crimping tool for wire end ferrules with 25, 35 and 50 mm[2]**
Crimping tool for wire end ferrules of 25, 35 and 50 mm[2] with and without plastic collar to DIN 46228 part 1 and 4(~ AWG 3...1)
- Three crimping stations corresponding to the conductor cross-sections
- Crimp according to Euro-Norm EN 60947-1
- Approval according to VG 95211 (military designation VG 95 236 T 14 B 002)
**J**
## **Technical data**
|**Technical data**||
|---|---|
|**Description of contact**<br>Type of contact|**PZ 50**<br>Wire end ferrules with/withoutplastic collar|
|Crimping range<br>mm2|25 ... 50|
|Crimping range 1 (with multiple crimping positions)<br>mm2|25|
|Crimping range 2 (with multiple crimping positions)<br>mm2|35|
|Crimping range 3 (with multiple crimping positions)<br>mm2|50|
|Plug width<br>mm||
|**Tool data**<br>Length<br>mm||260|
|---|---|---|
|Weight<br>g<br>**Information**||700|
|**Ordering data**|||
|**Version**||**Type**<br> **Qty.**<br>**Order No.**<br>PZ 50<br>1<br>**9006450000**|
## **Ordering data**
**Information Information**
## **Accessories**
**J.9**
**Tools**
## **Rechargeable torque screwdriver**
## **DMS 3**
## **DMS 3 Set**
## **DMS 3 rechargeable torque screwdriver**
- One-hand operation under all working conditions
- Switchable forward and reverse
- Two speeds: 200 and 400 rpm
- Precise torque settings from approx. 0.2 ... 3 Nm in 6 steps
- Consistent performance during battery discharge
- Grip swings easily from rod to pistol form
- Takes 1/4" bits held ball-bearing clamping mechanism (form E6.3)
- Safety lock prevents inadvertent operation
- Easy changeover from battery drive to manual operation up to 15 Nm
**J**
## **Technical data**
|**Technical data**||
|---|---|
|**Screwdriver**<br>Motor|2.4 V DC|
|Idling speed|200/400 min-1|
|Max. torque|3.0 Nm|
|Chuck|1/4" E 6.3 DIN 3126|
|Length|239 mm|
|Weight<br>**Battery**<br>Type|400 g<br>2 Ni-Cd batteries each 1.2 V|
|Weight<br>**Charger**<br>Input|122 g<br>230 V AC,50 Hz,50 mA|
|Output|2.9 V AC,1.4 A,4.1 VA|
|Charging time|1 hour|
|Weight|700 g|
## **Ordering data**
## **Accessories**
|**Type**<br> **Qty.**<br>**Order No.**<br>DMS 3<br>1<br>**9007440000**<br>Screwdriver incl. battery||**Type**<br> **Qty.**<br>**Order No.**<br>DMS 3 set 1 (screwdriver incl. battery, <br>1<br>**9007470000**<br>charger,bits, plastic carryingcase)*|
|---|---|---|
|||DMS 3 set 2 (as set1<br>1<br>**9007480000**<br>with 1 additional battery)|
|||*) refer to figure|
|**Type**<br> **Qty.**<br>**Order No.**<br>Spare battery<br>1<br>**9007450000**|||
|Charger<br>1<br>**9007460000**|||
**J.10**
**Tools**
## **Electric torque screwdriver**
## **DMS 2 Set**
- Torque adjustable in four steps for standard screws M2.5 to M4
- Selectable electric power cut-off upon reaching a preselected torque
- High repetition accuracy
- Start-up in low gear and switchover to operating rpm is controlled via the pressure on the screw head
- Switchable forward and reverse
- Fatigue-free working due to ergonomic design and low weight
- Ideal design for one-hand operation under all working conditions and at different working locations
- Low noise
- Low energy consumption
## **Technical data**
Rated voltage Frequency Rated power Current consumption rpm of spindle in search gear in working mode
**Torques** Level 1 (M 2.5) Level 2 (M 3) Level 3 (M 3.5) Level 4 (M4)
Weight incl. supply cable Weight Noise level to DIN 45 634
230 V 60 Hz 45 W 0.2 A 350 min[-1]
700 min[-1]
0.5 ± 0.1 Nm 0.7 ± 0.15 Nm 1.2 ± 0.2 Nm 1.7 ± 0.25 Nm 0.990 kg 0.820 kg 58 db (A)
**J**
Protection class II to DIN 57 740 DIN/VDE 0740 T.1 and T.2 EMC to EC directive 89/336/EWG CE mark
## **Ordering data**
**Standard equipment**
## **Accessories**
Balancer for hanging up the DMS 2
**==> picture [328 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|DMS 2 with 1/4" drive|1|0664600000|
|Form E 6.3 DIN 3126 with hang-up clip and 4 bits for slotted screws (Length: 50 mm)|
|Blade dimensions 0.5 x 3 / 0.6 x 3.5 / 0.8 x 4 / 1.0 x 5.5|
|Type|Qty.|Order No.|
|BAL 2 (balancer for hanging up the DMS 2)|1|0181800000|
**----- End of picture text -----**<br>
**J.11**
**Tools**
**J**
## Screwdrivers
## **Screwdrivers**
Weidmüller screwdrivers come in four different grip sizes, and are the result of a consistent grip concept which takes into account both the human hand and the different requirements when working
- Perfect handling with all grip sizes
- Maximum torques
- Optimum transmission of axial force
- Complete range including all commercial dimensions
## **SoftFinish-grip**
With the SoftFinish zone for use in dry conditions and for general applications, Weidmüller offers a complete range of screwdrivers that enables far higher torques and at the same time substantially more comfort due to the soft material of the grip.
## **Product benefits:**
## **SoftFinish electric**
**VDE-insulated screwdriver according to DIN EN 60900, IEC 900 for work on live equipment**
## **Product benefits:**
- The protective insulation directly injected onto the screwdriver blade ensures electrical safety, even in critical applications
- Safe for working at up to 1500 volts DC and 1000 volts AC
- Made of special soft material which is kind to the skin, the SoftFinish zone enables maximum torques
- Perfect ergonomic grip design for comfortable screw driving and optimum handling
- Version with solid steel tip can be used for chiselling
- You can choose from long-life extremely stressable blades in standard sizes
- Each screwdriver is individually tested in a water bath at 10,000 volts according to DIN EN 60900
- Perfect ergonomic grip design for comfortable screw driving and optimum handling
- Made of special soft material which is kind to the skin, the SoftFinish zone prevents slipping in critical situations and at the same time enables maximum torques
- ChromTop blade tip offers maximum corrosion protection and greatest possible dimensional accuracy of the blade geometry in the screw head over many years
**J.12**
**Tools**
## **Combined cutting and screw driving tool**
## **swifty[®]**
## **swifty[®] set**
that does not damage the edge; for cutting of copper cables with a diameter of up to 1.5 mm[2] solid and 2.5 mm[2] flexible.
## **swifty[®]**
- Cable cutting tool to mount on non-insulated screw drivers with a blade diameter of 3.5 mm
- Minimum manual force required
- Automatic opening of the cutter
- Ergonomically designed grip
## **swifty[®] set**
- Efficient operation:
- Only one tool for cable-processing in IDC-technology
- Suitable for screw and tension clamps
- Readily available pocket size
- For right-handed and left-handed use
- One-hand operation
**J**
## **Technical data**
**==> picture [157 x 61] intentionally omitted <==**
**----- Start of picture text -----**<br>
Maximum cutting capacity<br>Copper cable:<br>Solid cable (conductor cross-section) mm [2]<br>Flexible cable (conductor cross-section) mm [2]<br>Tool data<br>Length x width x height mm<br>Weight g<br>**----- End of picture text -----**<br>
## **Ordering data**
**==> picture [154 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|1.5|
|2.5|
|35 / 18 / 40|
|20|
|Type|Qty.|Order No.|
|swifty|[®]|(without screwdriver)|1|9006020000|
**----- End of picture text -----**<br>
**==> picture [154 x 33] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Type|Qty.|Order No.|
|swifty|[®]|set (with screwdriver)|1|9006060000|
|Screwdriver|1|9008330000|
|(SD 0.6 3.5x100)|
**----- End of picture text -----**<br>
**J.13**
**Tools**
## **VDE insulated screwdriver**
VDE insulated screwdriver sets, for working on live parts up to 1000 V AC and 1500 V DC, DIN EN 60900, IEC 900. safety tested GS, every one tested. Blade made from fully hardend, high-alloy chromium-vanadiummolybdenum steel, gunmetal finish.
**J**
## **SDI S**
**VDE insulated slot-head screwdriver, SDI DIN 7437, ISO 2380/2, output to DIN 5264, ISO 2380/1, SoftFinish grip**
**SDIK PH VDE insulated crosshead screwdriver, for Phillips screws, SDIK PH DIN 7438, ISO 8764/2-PH, output to ISO 8764-PH, SoftFinish grip**
## **SDIK PZ**
**VDE insulated crosshead screwdriver type Pozidriv SDIK PZ DIN 7438, ISO 8764/2-PZ, output to ISO 8764-PZ, SoftFinish grip**
## **SDIT**
**VDE insulated Torx[®] -screwdriver, SDIT SoftFinish grip**
**==> picture [241 x 438] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|Type|Size / SW|A|B|C|Order No.|
|SDI 0.4 x 2.5 x 75|0.4|2.5|80|9008370000|
|SDI 0.5 x 3.0 x 100|0.5|3.0|100|9008380000|
|SDI 0.6 x 3.5 x 100|0.6|3.5|100|9008390000|
|0.8 x 4.0 x 100|0.8|4.0|100|9008400000|
|SDI 1.0 x 4.5 x 125|1.0|4.5|125|9008910000|
|SDI 1.0 x 5.5 x 125|1.0|5.5|125|9008410000|
|SDI 1.2 x 6.5 x 150|1.2|6.5|125|9025870000|
|SDI 1.6 x 8.0 x 175|1.6|8.0|175|9008430000|
|SDI 0.4 x 2.0 x 60|0.4|2.0|60|9205690000|
|SDI 1.0 x 4.5 x 175|1.0|4.5|175|9205700000|
|SDI 1.0 x 5.5 x 175|1.0|5.5|175|9205710000|
|SDIK PH0|0|60|9008560000|
|SDIK PH1|1|80|9008570000|
|SDIK PH2|2|100|9008580000|
|SDIK PH3|3|150|9008590000|
|SDIK PZ1|1|80|9008900000|
|SDIK PZ2|2|100|9008890000|
|SDI T8|8|60|9201940000|
|SDI T10|10|80|9009640000|
|SDI T15|15|80|9009650000|
|SDI T20|20|80|9009660000|
|SDI T25|25|80|9009670000|
|SDI T30|30|100|9009680000|
|SDI T35|40|150|9009690000|
**----- End of picture text -----**<br>
## **SKI**
**VDE insulated hexagon socket wrench, SKI SoftFinish grip**
**==> picture [241 x 78] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|SKI 5.0 x 125|5|125|9009000000|
|SKI 5.5 x 125|5.5|125|9008990000|
|SKI 6.0 x 125|6|125|9008980000|
|SKI 7.0 x 125|7|125|9008970000|
|SKI 8.0 x 125|8|125|9008960000|
|SKI 9.0 x 125|9|125|9008950000|
|SKI 10.0 x 125|10|125|9008940000|
|SKI 11.0 x 125|11|125|9008930000|
|SKI 13.0 x 125|13|125|9008920000|
**----- End of picture text -----**<br>
**==> picture [34 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
Information<br>**----- End of picture text -----**<br>
**J.14**
**Tools**
**J**
## **Uninsulated screwdriver**
Weidmüller SoftFinish screwdriver for general uses, blade made from fully hardened, high-alloy chromium-vanadium-molybdenum steel, matt chrome finish.
## **SDI S**
**Slotted screwdriver with round blade SD DIN 5265, ISO 2380/2, output to DIN 5264, ISO 2380/1, ChromTop tip, SoftFinish grip**
## **SDK PH**
**Crosshead screwdriver, Phillips, SDK PH DIN 5262, ISO 8764/2-PH, ouput to ISO 8764-PH, ChromTop tip, SoftFinish grip**
**==> picture [250 x 177] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|Type|Size / SW|A|B|C|Order No.|
|SD 0.4 x 2.0 x 60|0.4|2.0|60|9037160000|
|SD 0.4 x 2.5 x 75|0.4|2.5|75|9009030000|
|SD 0.5 x 3.0 x 80|0.5|3.0|80|9008320000|
|SD 0.6 x 3.5 x 100|0.6|3.5|100|9008330000|
|SD 0.6 x 3.5 x 200|0.6|3.5|200|9010110000|
|SD 0.8 x 4.0 x 100|0.8|4.0|100|9008340000|
|4IINANNnNuJIjNIuN]—|SD 1.2 x 6.5 x 150|1.2|6.5|150|9009010000|
|SD 0.8 x 4.5 x 125|0.8|4.5|125|9009020000|
|SD 1.0 x 5.5 x 150|1.0|5.5|150|9008350000|
|SDK PH0|0|60|9008470000|
|SDK PH1|1|80|9008480000|
|SDK PH2|2|100|9008490000|
|SDK PH3|3|150|9008500000|
**----- End of picture text -----**<br>
## **SDK PZ**
**Crosshead screwdriver, Pozidriv, SDK PZ DIN 5262, ISO 8764/2-PZ, ouput to ISO 8764/1-PZ, ChromTop tip, SoftFinish grip**
**==> picture [241 x 33] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|SDK PZ0|0|60|9008520000|
|SDK PZ1|1|80|9008530000|
|SDK PZ2|2|100|9008540000|
|SDK PZ3|3|150|9008550000|
**----- End of picture text -----**<br>
## **SD TH**
**Torx[®] TH screwdriver with hole in tip of blade (tamper-tesistant), SD TH for screwing Torx[®] and Torx[®] -TH security screws (pin in centre of Torx recess), ChromTop tip, SoftFinish grip**
**==> picture [250 x 72] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|SD TH8|8|60|9009190000|
|SD TH10|10|80|9009180000|
|SD TH15|15|80|9009170000|
|SD TH20|20|100|9009160000|
|SD TH25|25|100|9009150000|
|SD TH30|30|115|9009140000|
|.|
|ySINMmNNNNINmIN]|
**----- End of picture text -----**<br>
## **SK**
**Hexagon socket wrench SK DIN 3125, ouput to DIN 3125, SoftFinish grip**
**==> picture [241 x 78] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|SK 5.5 x 125|5.5|125|9009120000|
|SK 6.0 x 125|6|125|9009110000|
|SK 7.0 x 125|7|125|9009100000|
|SK 8.0 x 125|8|125|9009090000|
|SK 9.0 x 125|9|125|9009080000|
|SK 10.0 x 125|10|125|9009070000|
|SK 11.0 x 125|11|125|9009060000|
|SK 12.0 x 125|12|125|9009050000|
|SK 13.0 x 125|13|125|9009040000|
**----- End of picture text -----**<br>
**==> picture [34 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
Information<br>**----- End of picture text -----**<br>
**J.15**
**Tools**
## **Wrench set Weidmüller**
Allen key made from fully hardened, high-alloy chromium-vanadiumsteel, to DIN ISO 2936 L (DIN 911), surface high-quality refined.
**Type Size / SW A B C Order No.** 1.5 : holds 2 2.5 3 4 5 a. ~~“<< i |~~ he ~~CC~~ 6 ~~Eee~~ 8 10 SK WSD-S 1.5-10.0 **9008850000** ~~—————~~
## **SK WSD S**
**9-piece offset screwdriver set in Prostar holder** , with **MagicRing** : holds standard screws (size 3 and larger) in any position thanks to spring steel ring, with **ball point** : for working at angles up to 25°.
## **SK S**
**J**
2 2.5 3 4 5 8 6 SKS 2.0-8.0 **9008860000** Ps ~~—_—<—=s~~ 2 : holds standard 2.5 3 4 5 6 8 SKS 2.0-8.0 MR **9008870000** 9 10 15 20 25 27 30 40 TH-S 9-40 **9008880000**
**7-piece Allen key set**
## **SK S**
**7-piece Allen key set with MagicRing and ball point** : holds standard screws (size 3 and larger) in any position thanks to spring steel ring, with ball point: for working at angles up to 25°.
## **TH S**
## **8-piece Torx®-TH screwdriver set**
with hole in the blade point (tamper-proof), for screwing Torx® and Torx®-TH tamper-proof screws (centre pin in profile)
**Information**
**J.16**
**Tools**
## DMS manual / DMSI manual
## **Torque screwdrivers with insulation up to 1000 V (VDE)**
## **• DMSI manual**
The “DMSI manual” with integral window torque scale combined with a Weidmüller 1000 V insulated (VDE) interchangeable blade ensures controlled tightening of screws plus reliability in electrical applications.
Every 1000 V insulated handle (VDE) and blade (VDE) is tested and provides the necessary safety up to 1000 V AC/1500 V DC.
## **Torque screwdrivers**
## **• DMS manual**
**==> picture [110 x 63] intentionally omitted <==**
**----- Start of picture text -----**<br>
/ N B 10009<br>Scale<br>**----- End of picture text -----**<br>
This is a versatile tool suitable for a variety of jobs, with integral scale for easy reading of the torque value plus a Weidmüller interchangeable blade.
**J**
## **Each model is available with two torque ranges:**
- 0.5 to 1.7 Nm
- 2.0 to 8.0 Nm
- setting tool included
## **Advantages:**
- Compact and especially lightweight design
Setting tool
- Torque set with special tool (included) to ensure the right setting
- Ergonomic handle size to match the torque range
- Every tool checked and given an ID No., 100% quality control with verification and product reference
- Audible, unmistakable click upon reaching the torque, no unnecessary effort
- Interchangeable blade made from high-quality wear-resistant tool steel
- All tools comply with the accuracy stipulations of: EN ISO 6798, BS EN 26789, ASME B107.14M
- Operating accuracy: ±6% of set scale value
**J.17**
**Tools**
## **Uninsulated torque screwdriver**
## **DMS manual**
**Torque-screwdriver EN ISO 6798, BS EN 26789, ASME B107.14M**
**Type Size / SW A B C Order No.** DMS MANUELL 0.5-1.7 0.5 - 1.7 Nm **9918370000** DMS MANUELL 2.0-8.0 2.0 - 8.0 Nm **9918380000**
## **WK K S**
**Interchangeable blades for torque-screwdriver output according to DIN 5264, ISO 2380/1**
**==> picture [241 x 42] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|WK S 0.4 x 2.5|max. 0.6 Nm|0.4|2.5|175|9918520000|
|WK S 0.5 x 3.0|max. 0.6 Nm|0.5|3.0|175|9918530000|
|WK S 0.6 x 3.5|max. 1.1 Nm|0.6|3.5|175|9918540000|
|WK S 0.8 x 4.0|max. 2.5 Nm|0.8|4.0|175|9918550000|
|WK S 1.0 x 5.5|max. 3.8 Nm|1.0|5.5|175|9918560000|
**----- End of picture text -----**<br>
## **WK K PZ**
**Interchangeable blades for torque-screwdriver output according to DIN 5260-PZ, ISO 8764/1-PZ**
**==> picture [241 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|WK K PZ0|max. 0.9 Nm|175|9918600000|
|WK K PZ1|max. 3.8 Nm|175|9918610000|
|WK K PZ2|max. 5.5 Nm|175|9918620000|
**----- End of picture text -----**<br>
**J**
## **WK K PH**
**Interchangeable blades for torque-screwdriver output according to DIN 5260-PH, ISO 8764/1-PH**
**==> picture [241 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|WK K PH0|max. 0.9 Nm|175|9918570000|
|WK K PH1|max. 3.8 Nm|175|9918580000|
|WK K PH2|max. 5.5 Nm|175|9918590000|
**----- End of picture text -----**<br>
**Information**
**J.18**
**Tools**
**J**
## **VDE insulated torque screwdriver**
VDE insulated torque screwdriver Weidmüller SoftFinish electric for work on live parts up to 1000 Vac and 1500 Vdc, DIN EN 60900, IEC 900. GS symbol, every one tested.
## **DMSI manual**
**VDE insulated torque-screwdriver EN ISO 6798, BS EN 26789, ASME B107.14M**
**==> picture [241 x 42] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|Type|Size / SW|A|B|C|Order No.|
|DMSI MANUELL 0.5-1.7|0.5 - 1.7 Nm|9918390000|
|DMSI MANUELL 2.0-8.0|2.0 - 8.0 Nm|9918400000|
**----- End of picture text -----**<br>
## **WK SI**
**VDE insulated interchangeable blades for VDE insulated torquescrewdriver output according to DIN 5264, ISO 2380/1**
**==> picture [241 x 42] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|WK SI 0.4 x 2.5|max. 0.6 Nm|0.4|2.5|175|9918410000|
|WK SI 0.5 x 3.0|max. 0.6 Nm|0.5|3.0|175|9918420000|
|WK SI 0.6 x 3.5|max. 1.1 Nm|0.6|3.5|175|9918430000|
|WK SI 0.8 x 4.0|max. 2.5 Nm|0.8|4.0|175|9918440000|
|WK SI 1.0 x 5.5|max. 3.8 Nm|1.0|5.5|175|9918450000|
**----- End of picture text -----**<br>
## **WK IK PH**
**VDE insulated interchangeable blades for VDE insulated torquescrewdriver output according to DIN 5260-PH, ISO 8764/1-PH**
**==> picture [241 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|WK IK PH0|max. 0.9 Nm|175|9918460000|
|WK IK PH1|max. 3.8 Nm|175|9918470000|
|WK IK PH2|max. 5.5 Nm|175|9918480000|
**----- End of picture text -----**<br>
## **WK IK PZ**
**==> picture [505 x 30] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|WK IK PZ0|max. 0.9 Nm|175|9918490000|
|VDE insulated interchangeable blades for VDE insulated torque-|WK IK PZ1|max. 3.8 Nm|175|9918500000|
|screwdriver|
|WK IK PZ2|max. 5.5 Nm|175|9918510000|
|output according to DIN 5260-PZ, ISO 8764/1-PZ|
**----- End of picture text -----**<br>
**Information**
**J.19**
**Tools**
##
## **IS 4, IS 6, IS 8**
## **Allen key**
## Allen key, with spigot
- Surface nickel-plated
- Made from hardened chromium-vanadium steel
- According to DIN 6911
- Designed for screws to DIN 6912
## **IS 2 KG; IS 3 KG; IS 4 KG**
## **Hexagon screwdriver**
Hexagon screwdriver with cross-grip made from high-quality plastics
- Surface nickel-plated
- Made from hardened chromium-vanadium steel
- According to DIN 6911
- Designed for screws to DIN 6912
## **BIT E6.3Z, SDIZ**
## **for fixing sockets**
Bits and screwdrivers with shouldered blades for fixing sockets to the Weidmüller range of modular terminals.
- No damage to walls around contacts
- Made from hardened chrome-vanadium steel
- Suitable for all Weidmüller sockets
- Bit holders available for E6.3
- DIN 3126 for bits and DIN EN 60900, IEC 900 for screwdrivers
## **Technical data**
## **Technical data**
## **Technical data**
## **J**
## **Ordering data**
**==> picture [154 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|Qty.|Order No.|
|IS 4|1|0485100000|
|IS 6|1|0407900000|
|IS 8|1|0235000000|
**----- End of picture text -----**<br>
## **Ordering data**
## **Ordering data**
**==> picture [328 x 50] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|Type|Qty.|Order No.|Type|Blade|Order No.|
|IS 2 KG|1|1806630000|BIT E6.3Z|0.8 x 4.0 x 39|9025590000|
|IS 3 KG|1|1806650000|BIT E6.3Z|0.6 x 3.5 x 39|9025570000|
|IS 4 KG|1|1806660000|
|SDIZ|0.8 x 4.0|9008460000|
|SDIZ|0.3 x 3.5|9008450000|
**----- End of picture text -----**<br>
**J.20**
**Wire end ferrules / Insulated cable lugs**
## Wire end ferrules / Insulated cable lugs
**Weidmüller stocks a comprehensive range of wire end ferrules and insulated cable lugs for immediate supply.**
## **Wire end ferrules**
Wire end ferrules ensure the long-term quality of electrical connections. Another advantage is their usefulness during installation. The wide range of products embraces wire end ferrules with or without plastic collars and twin wire end ferrules in all the colours normally required by users.
AS **Insulated cable lugs** Insulated cable lugs ensure the long-term quality of electrical connections. Most of the products in the range (apart from the butt connectors) have a conical inlet. This guarantees optimum entry of the conductor as the strands are automatically centred.
**J**
**J.21**
**Wire end ferrules with plastic collar**
## **J**
- Polypropylene conical cable entry
**==> picture [133 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
L2<br>L1<br>ø D1<br>ø D2<br>S1<br>S2<br>**----- End of picture text -----**<br>
- Heat-resistant up to 105 °C
- Cable entry made from a not readily flammable material on request
For conductors from 0.14 to 150 mm[2] (AWG 26-300MCM) Tin-plated copper Dimensional tolerances to DIN 46228 part 4
## **Ordering data**
**Weidmüller colour code packed loose**
**==> picture [368 x 372] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type ø mm [2] AWG L1 L2 D1 D2 S1 S2 Stripping length Colour Qty. Order No.<br>H0.25/10 0.25 24 10.0 6.0 0.8 1.8 0.15 0.25 8.0 l light blue 500 9025740000<br>H0.25/12 0.25 24 12.0 8.0 0.8 1.8 0.15 0.25 10.0 l light blue 500 9025760000<br>H0.34/10 0.34 22 10.0 6.0 0.8 2.0 0.15 0.25 8.0 l turquoise 500 9025750000<br>H0.34/12 0.34 22 12.0 8.0 0.8 2.0 0.15 0.25 10.0 l turquoise 500 9025770000<br>H0.5/12 0.50 20 12.0 6.0 1.0 2.6 0.15 0.25 8.0 l orange 500 0409500000<br>H0.5/14 0.50 20 14.0 8.0 1.0 2.6 0.15 0.25 10.0 l orange 500 0690700000<br>H0.5/16 0.50 20 16.0 10.0 1.0 2.6 0.15 0.25 12.0 l orange 500 9025870000<br>H0.75/12 0.75 18 12.0 6.0 1.2 2.8 0.15 0.25 8.0 m white 500 0409600000<br>H0.75/14 0.75 18 14.0 8.0 1.2 2.8 0.15 0.25 10.0 m white 500 0462900000<br>H0.75/16 0.75 18 16.0 10.0 1.2 2.8 0.15 0.25 12.0 m white 500 9025860000<br>H0.75/18 0.75 18 18.0 12.0 1.2 2.8 0.15 0.25 14.0 m white 500 9025910000<br>H1.0/12 1.00 17 12.0 6.0 1.4 3.0 0.15 0.25 8.0 l yellow 500 0409700000<br>H1.0/14 1.00 17 14.0 8.0 1.4 3.0 0.15 0.25 10.0 l yellow 500 0463000000<br>H1.0/16 1.00 17 16.0 10.0 1.4 3.0 0.15 0.25 12.0 l yellow 500 9025950000<br>H1.0/18 1.00 17 18.0 12.0 1.4 3.0 0.15 0.25 15.0 l yellow 500 9025930000<br>H1.5/14 1.50 16 14.0 8.0 1.7 3.5 0.15 0.25 10.0 l red 500 0463100000<br>H1.5/16 1.50 16 16.0 10.0 1.7 3.5 0.15 0.25 12.0 l red 500 0635100000<br>H1.5/24 1.50 16 24.0 18.0 1.7 3.5 0.15 0.25 20.0 l red 500 0565600000<br>H2.5/14D 2.50 14 14.0 8.0 2.2 4.2 0.15 0.25 10.0 l blue 500 9019160000<br>H2.5/18D 2.50 14 18.0 12.0 2.2 4.2 0.15 0.25 14.0 l blue 500 9019170000<br>H2.5/24D 2.50 14 24.0 18.0 2.2 4.2 0.15 0.25 20.0 l blue 500 9019180000<br>H4.0/17D 4.00 12 17.0 10.0 2.8 4.8 0.2 0.3 12.0 l grey 500 9019190000<br>H4.0/20D 4.00 12 20.0 12.0 2.8 4.8 0.2 0.3 14.0 l grey 500 9019200000<br>H4.0/26D 4.00 12 26.0 18.0 2.8 4.8 0.2 0.3 20.0 l grey 100 9019210000<br>H6.0/20 6.00 10 20.0 12.0 3.5 6.3 0.2 0.3 14.0 l black 100 0533500000<br>H6.0/26 6.00 10 26.0 18.0 3.5 6.3 0.2 0.3 20.0 l black 100 0565700000<br>H10.0/22 10.00 7 22.0 12.0 4.5 7.6 0.2 0.4 15.0 l ivory 100 0534200000<br>H10.0/28 10.00 7 28.0 18.0 4.5 7.6 0.2 0.4 21.0 l ivory 100 0565800000<br>H16.0/24 16.00 6 24.0 12.0 5.8 8.8 0.2 0.4 15.0 l green 100 0565900000<br>H16.0/28 16.00 6 28.0 18.0 5.8 8.8 0.2 0.4 21.0 l green 100 0566000000<br>H25.0/30 25.00 3 30.0 16.0 7.3 11.2 0.2 0.4 18.0 l brown 50 0317000000<br>H25.0/36 25.00 3 36.0 22.0 7.3 11.2 0.2 0.4 24.0 l brown 50 0317100000<br>H35.0/30 35.00 2 30.0 16.0 8.3 12.7 0.2 0.4 19.0 l beige 50 0317200000<br>H35.0/39 35.00 2 39.0 25.0 8.3 12.7 0.2 0.4 28.0 l beige 50 0317300000<br>H50.0/36 50.00 1 36.0 20.0 10.3 15.0 0.3 0.5 26.0 l olive green 50 0444200000<br>H70.0/40 70.00 2/0 37.0 20.0 12.7 16.0 0.35 0.6 26.0 l yellow 25 9028200000<br>H95.0/44 95.00 3/0 44.0 25.0 14.7 18.0 0.35 0.6 31.0 l red 25 9028210000<br>H120.0/50 120.00 4/0 50.0 30.0 16.5 21.0 0.5 0.7 36.0 l blue 25 9028220000<br>H150.0/54 150.00 300 MCM 54.0 32.0 18.5 23.5 0.5 0.75 38.0 l yellow 25 9028230000<br>**----- End of picture text -----**<br>
## **Ordering data**
## **Weidmüller colour code**
|**in multipack bag**|**Type**<br>**ø mm2**<br>**AWG**<br>**L1**<br>**L2**<br>**D1**<br>**D2**<br>**S1**<br>**S2**<br>**Stripping length Colour**<br>**Qty.**<br>**Order No.**|
|---|---|
||H0.14/10<br>0.14<br>26<br>10.0<br>6.0<br>0.6<br>1.5<br>0.15<br>0.25<br>8.0<br>l grey<br>500<br>**9005180000**|
||H0.14/12<br>0.14<br>26<br>12.0<br>8.0<br>0.6<br>1.5<br>0.15<br>0.25<br>10.0<br>l grey<br>500<br>**9028240000**|
||H0.25/10<br>0.25<br>24<br>10.0<br>6.0<br>0.8<br>1.8<br>0.15<br>0.25<br>8.0<br>llight blue<br>500<br>**9026050000**|
||H0.25/12<br>0.25<br>24<br>12.0<br>8.0<br>0.8<br>1.8<br>0.15<br>0.25<br>10.0<br>llight blue<br>500<br>**9025780000**|
||H0.34/10<br>0.34<br>22<br>10.0<br>6.0<br>0.8<br>2.0<br>0.15<br>0.25<br>8.0<br>l turquoise<br>500<br>**9026030000**|
||H0.34/12<br>0.34<br>22<br>12.0<br>8.0<br>0.8<br>2.0<br>0.15<br>0.25<br>10.0<br>l turquoise<br>500<br>**9025790000**|
||H0.5/10<br>0.50<br>20<br>10.0<br>6.0<br>1.0<br>2.6<br>0.15<br>0.25<br>8.0<br>l orange<br>500<br>**9028260000**|
||H0.5/14<br>0.50<br>20<br>14.0<br>8.0<br>1.0<br>2.6<br>0.15<br>0.25<br>10.0<br>l orange<br>500<br>**9026060000**|
||H0.5/16<br>0.50<br>20<br>16.0<br>10.0<br>1.0<br>2.6<br>0.15<br>0.25<br>12.0<br>l orange<br>500<br>**9028270000**|
||H0.75/12<br>0.75<br>18<br>12.0<br>6.0<br>1.2<br>2.8<br>0.15<br>0.25<br>8.0<br>mwhite<br>500<br>**9028280000**|
||H0.75/14<br>0.75<br>18<br>14.0<br>8.0<br>1.2<br>2.8<br>0.15<br>0.25<br>10.0<br>mwhite<br>500<br>**9026070000**|
||H0.75/16<br>0.75<br>18<br>16.0<br>10.0<br>1.2<br>2.8<br>0.15<br>0.25<br>12.0<br>mwhite<br>500<br>**9028290000**|
||H0.75/18<br>0.75<br>18<br>18.0<br>12.0<br>1.2<br>2.8<br>0.15<br>0.25<br>14.0<br>mwhite<br>500<br>**9028300000**|
||H1.0/12<br>1.00<br>17<br>12.0<br>6.0<br>1.4<br>3.0<br>0.15<br>0.25<br>8.0<br>l yellow<br>500<br>**9028310000**|
||H1.0/14<br>1.00<br>17<br>14.0<br>8.0<br>1.4<br>3.0<br>0.15<br>0.25<br>10.0<br>l yellow<br>500<br>**9026080000**|
||H1.0/16<br>1.00<br>17<br>16.0<br>10.0<br>1.4<br>3.0<br>0.15<br>0.25<br>12.0<br>l yellow<br>500<br>**9028320000**|
||H1.0/18<br>1.00<br>17<br>18.0<br>12.0<br>1.4<br>3.0<br>0.15<br>0.25<br>15.0<br>l yellow<br>500<br>**9028340000**|
||H1.5/14<br>1.50<br>16<br>14.0<br>8.0<br>1.7<br>3.5<br>0.15<br>0.25<br>10.0<br>l red<br>500<br>**9026090000**|
||H1.5/16<br>1.50<br>16<br>16.0<br>10.0<br>1.7<br>3.5<br>0.15<br>0.25<br>12.0<br>l red<br>500<br>**9028350000**|
||H2.5/14<br>2.50<br>14<br>14.0<br>8.0<br>2.2<br>4.2<br>0.15<br>0.25<br>10.0<br>l blue<br>500<br>**9026100000**|
||H4.0/17<br>4.00<br>12<br>17.0<br>10.0<br>2.8<br>4.8<br>0.2<br>0.3<br>12.0<br>l grey<br>250<br>**9026010000**|
|||
**J.22**
**Wire end ferrules with plastic collar**
• Polypropylene conical cable entry
**==> picture [133 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
L2<br>L1<br>ø D1<br>ø D2<br>S1<br>S2<br>**----- End of picture text -----**<br>
• Heat-resistant up to 105 °C
- Cable entry made from a not readily flammable material on request
For conductors from 0.5 to 2.5 mm[2] (AWG 22-14) Tin-plated copper Dimensional tolerances to DIN 46228 part 4
## **Ordering data**
**Weidmüller colour code Strip of wire end ferrules**
|**Weidmüller colour code**|**Ordering data**|
|---|---|
|**Strip of wire end ferrules**<br>**Weidmüller colour code**<br>**Reel of wire end ferrules**|**Type**<br>**ø mm2**<br>**AWG**<br>**L1**<br>**L2**<br>**D1**<br>**D2**<br>**S1**<br>**S2**<br>**Stripping length Colour**<br>**Qty.**<br>**Order No.**|
||H0.5/14<br>0.50<br>20<br>14.0<br>8.0<br>1.0<br>2.6<br>0.15<br>0.25<br>10.0<br>l orange<br>500<br>**9004270000**|
||H0.75/14<br>0.75<br>18<br>14.0<br>8.0<br>1.2<br>2.8<br>0.15<br>0.25<br>10.0<br>mwhite<br>500<br>**9004290000**|
||H1.0/14<br>1.00<br>17<br>14.0<br>8.0<br>1.4<br>3.0<br>0.15<br>0.25<br>10.0<br>l yellow<br>500<br>**9004320000**|
||H1.5/14<br>1.50<br>16<br>14.0<br>8.0<br>1.7<br>3.2<br>0.15<br>0.25<br>10.0<br>l red<br>500<br>**9004340000**|
||H2.5/14D<br>2.50<br>14<br>14.0<br>8.0<br>2.2<br>4.0<br>0.15<br>0.25<br>11.0<br>l blue<br>500<br>**9004360000**|
|||
||**Ordering data**|
||**Type**<br>**ø mm2**<br>**AWG**<br>**L1**<br>**L2**<br>**D1**<br>**D2**<br>**S1**<br>**S2**<br>**Stripping length Colour**<br>**Qty.**<br>**Order No.**|
||H0.34/12<br>0.34<br>22<br>12.0<br>8.0<br>0.8<br>2.0<br>0.15<br>0.25<br>10.0<br>l turquoise<br>5000<br>**9004390000**|
||H0.5/14<br>0.50<br>20<br>14.0<br>8.0<br>1.0<br>2.6<br>0.15<br>0.25<br>10.0<br>l orange<br>5000<br>**9005810000**|
||H0.75/14<br>0.75<br>18<br>14.0<br>8.0<br>1.2<br>2.8<br>0.15<br>0.25<br>10.0<br>mwhite<br>5000<br>**9005820000**|
||H1.0/14<br>1.00<br>17<br>14.0<br>8.0<br>1.4<br>3.0<br>0.15<br>0.25<br>11.0<br>l yellow<br>5000<br>**9005830000**|
||H1.5/14<br>1.50<br>16<br>14.0<br>8.0<br>1.7<br>3.2<br>0.15<br>0.25<br>10.0<br>l red<br>5000<br>**9005840000**|
||H2.5/14D<br>2.50<br>14<br>14.0<br>8.0<br>2.2<br>4.0<br>0.15<br>0.25<br>11.0<br>l blue<br>3000<br>**9005850000**|
|||
**J**
**J.23**
**Wire end ferrules with plastic collar**
## **J**
- Polypropylene conical cable entry
**==> picture [133 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
L2<br>L1<br>ø D1<br>ø D2<br>S1<br>S2<br>**----- End of picture text -----**<br>
- Heat-resistant up to 105 °C
- Cable entry made from a not readily flammable material on request
For conductors from 0.5 to 50 mm[2] (AWG 20-1) Tin-plated copper Dimensional tolerances to DIN 46228 part 4
## **Ordering data**
**DIN colour code packed loose**
|**packed loose**<br>**DIN colour code**<br>**in multipack bag**|**Type**<br>**ø mm2**<br>**AWG**<br>**L1**<br>**L2**<br>**D1**<br>**D2**<br>**S1**<br>**S2**<br>**Stripping length Colour**<br>**VG***<br>**Qty.**<br>**Order No.**|
|---|---|
||H0.5/12D<br>0.50<br>20<br>12.0<br>6.0<br>1.0<br>2.6<br>0.15<br>0.25<br>8.0<br>mwhite<br>T 20A 001 A 500<br>**9019000000**|
||H0.5/14D<br>0.50<br>20<br>14.0<br>8.0<br>1.0<br>2.6<br>0.15<br>0.25<br>10.0<br>mwhite<br>T 20A 002 A 500<br>**9019010000**|
||H0.5/16D<br>0.50<br>20<br>16.0<br>10.0<br>1.0<br>2.6<br>0.15<br>0.25<br>12.0<br>mwhite<br>T 20A 003 A 500<br>**9019020000**|
||H0.75/12D<br>0.75<br>18<br>12.0<br>6.0<br>1.2<br>2.8<br>0.15<br>0.25<br>8.0<br>l grey<br>T 20A 004 A 500<br>**9019030000**|
||H0.75/14D<br>0.75<br>18<br>14.0<br>8.0<br>1.2<br>2.8<br>0.15<br>0.25<br>10.0<br>l grey<br>T 20A 005 A 500<br>**9019040000**|
||H0.75/16D<br>0.75<br>18<br>16.0<br>10.0<br>1.2<br>2.8<br>0.15<br>0.25<br>12.0<br>l grey<br>T 20A 006 A 500<br>**9019050000**|
||H0.75/18D<br>0.75<br>18<br>18.0<br>12.0<br>1.2<br>2.8<br>0.15<br>0.25<br>14.0<br>l grey<br>T 20A 007 A 500<br>**9019060000**|
||H1.0/12D<br>1.00<br>17<br>12.0<br>6.0<br>1.4<br>3.0<br>0.15<br>0.25<br>8.0<br>l red<br>T 20A 008 A 500<br>**9019070000**|
||H1.0/14D<br>1.00<br>17<br>14.0<br>8.0<br>1.4<br>3.0<br>0.15<br>0.25<br>10.0<br>l red<br>T 20A 009 A 500<br>**9019080000**|
||H1.0/16D<br>1.00<br>17<br>16.0<br>10.0<br>1.4<br>3.0<br>0.15<br>0.25<br>12.0<br>l red<br>T 20A 010 A 500<br>**9019100000**|
||H1.0/18D<br>1.00<br>17<br>18.0<br>12.0<br>1.4<br>3.0<br>0.15<br>0.25<br>15.0<br>l red<br>T 20A 011 A 500<br>**9019110000**|
||H1.5/14D<br>1.50<br>16<br>14.0<br>8.0<br>1.7<br>3.5<br>0.15<br>0.25<br>10.0<br>lblack<br>T 20A 012 A 500<br>**9019120000**|
||H1.5/16D<br>1.50<br>16<br>16.0<br>10.0<br>1.7<br>3.5<br>0.15<br>0.25<br>12.0<br>lblack<br>T 20A 013 A 500<br>**9019130000**|
||H1.5/18D<br>1.50<br>16<br>18.0<br>12.0<br>1.7<br>3.5<br>0.15<br>0.25<br>15.0<br>lblack<br>T 20A 014 A 500<br>**9019140000**|
||H1.5/24D<br>1.50<br>16<br>24.0<br>18.0<br>1.7<br>3.5<br>0.15<br>0.25<br>20.0<br>lblack<br>T 20A 015 A 500<br>**9019150000**|
||H2.5/14D<br>2.50<br>14<br>14.0<br>8.0<br>2.2<br>4.2<br>0.15<br>0.25<br>10.0<br>l blue<br>T 20A 016 A 500<br>**9019160000**|
||H2.5/18D<br>2.50<br>14<br>18.0<br>12.0<br>2.2<br>4.2<br>0.15<br>0.25<br>14.0<br>l blue<br>T 20A 017 A 500<br>**9019170000**|
||H2.5/24D<br>2.50<br>14<br>24.0<br>18.0<br>2.2<br>4.2<br>0.15<br>0.25<br>20.0<br>l blue<br>T 20A 018 A 500<br>**9019180000**|
||H4.0/17D<br>4.00<br>12<br>17.0<br>10.0<br>2.8<br>4.8<br>0.2<br>0.3<br>12.0<br>l grey<br>T 20A 019 A 500<br>**9019190000**|
||H4.0/20D<br>4.00<br>12<br>20.0<br>12.0<br>2.8<br>4.8<br>0.2<br>0.3<br>14.0<br>l grey<br>T 20A 020 A 500<br>**9019200000**|
||H4.0/26D<br>4.00<br>12<br>26.0<br>18.0<br>2.8<br>4.8<br>0.2<br>0.3<br>20.0<br>l grey<br>T 20A 021 A 100<br>**9019210000**|
||H6.0/20D<br>6.00<br>10<br>20.0<br>12.0<br>3.5<br>6.3<br>0.2<br>0.3<br>14.0<br>l yellow<br>T 20A 022 A 100<br>**9019220000**|
||H6.0/26D<br>6.00<br>10<br>26.0<br>18.0<br>3.5<br>6.3<br>0.2<br>0.3<br>20.0<br>l yellow<br>T 20A 023 A 100<br>**9019230000**|
||H10.0/22D<br>10.00<br>7<br>22.0<br>12.0<br>4.5<br>7.6<br>0.2<br>0.4<br>15.0<br>l red<br>T 20A 024 A 100<br>**9019240000**|
||H10.0/28D<br>10.00<br>7<br>28.0<br>18.0<br>4.5<br>7.6<br>0.2<br>0.4<br>21.0<br>l red<br>T 20A 025 A 100<br>**9019250000**|
||H16.0/24D<br>16.00<br>6<br>24.0<br>12.0<br>5.8<br>8.8<br>0.2<br>0.4<br>15.0<br>l blue<br>T 20A 026 A 100<br>**9019260000**|
||H16.0/28D<br>16.00<br>6<br>28.0<br>18.0<br>5.8<br>8.8<br>0.2<br>0.4<br>21.0<br>l blue<br>T 20A 027 A 100<br>**9019270000**|
||H25.0/30D<br>25.00<br>3<br>30.0<br>16.0<br>7.3<br>11.2<br>0.2<br>0.4<br>18.0<br>l yellow<br>T 20A 028 A<br>50<br>**9019280000**|
||H25.0/36D<br>25.00<br>3<br>36.0<br>22.0<br>7.3<br>11.2<br>0.2<br>0.4<br>24.0<br>l yellow<br>T 20A 030 A<br>50<br>**9019300000**|
||H35.0/30D<br>35.00<br>2<br>30.0<br>18.0<br>8.3<br>12.7<br>0.2<br>0.4<br>21.0<br>l red<br>T 20A 032 A<br>50<br>**9019320000**|
||H35.0/30D<br>35.00<br>2<br>30.0<br>16.0<br>8.3<br>12.7<br>0.2<br>0.4<br>19.0<br>l red<br>T 20A 031 A<br>50<br>**9019310000**|
||H35.0/39D<br>35.00<br>2<br>39.0<br>25.0<br>8.3<br>12.7<br>0.2<br>0.4<br>28.0<br>l red<br>T 20A 033 A<br>50<br>**9019330000**|
||H50.0/36D<br>50.00<br>1<br>36.0<br>20.0<br>10.3<br>15.0<br>0.3<br>0.5<br>26.0<br>l blue<br>T 20A 034 A<br>50<br>**9019340000**|
||H50.0/40D<br>50.00<br>1<br>40.0<br>25.0<br>10.3<br>15.0<br>0.3<br>0.5<br>31.0<br>l blue<br>T 20A 035 A<br>50<br>**9019350000**|
|||
||**Ordering data**|
||**Type**<br>**ø mm2**<br>**AWG**<br>**L1**<br>**L2**<br>**D1**<br>**D2**<br>**S1**<br>**S2**<br>**Stripping length Colour**<br>**VG***<br>**Qty.**<br>**Order No.**|
||H0.5/14D<br>0.50<br>20<br>14.0<br>8.0<br>1.0<br>2.6<br>0.15<br>0.25<br>10.0<br>mwhite<br>T 20A 002 A 500<br>**9019400000**|
||H0.75/14D<br>0.75<br>18<br>14.0<br>8.0<br>1.2<br>2.8<br>0.15<br>0.25<br>10.0<br>l grey<br>T 20A 005 A 500<br>**9019410000**|
||H1.0/14D<br>1.00<br>17<br>14.0<br>8.0<br>1.4<br>3.0<br>0.15<br>0.25<br>10.0<br>l red<br>T 20A 009 A 500<br>**9019420000**|
||H1.5/14D<br>1.50<br>16<br>14.0<br>8.0<br>1.7<br>3.5<br>0.15<br>0.25<br>10.0<br>lblack<br>T 20A 012 A 500<br>**9019430000**|
||H1.5/24D<br>1.50<br>16<br>24.0<br>18.0<br>1.7<br>3.5<br>0.15<br>0.25<br>20.0<br>lblack<br>T 20A 015 A 500<br>**9004140000**|
||H2.5/14<br>2.50<br>14<br>14.0<br>8.0<br>2.2<br>4.2<br>0.15<br>0.25<br>10.0<br>l blue<br>500<br>**9026100000**|
||H4.0/17<br>4.00<br>12<br>17.0<br>10.0<br>2.8<br>4.8<br>0.2<br>0.3<br>12.0<br>l grey<br>250<br>**9026010000**|
|||
## **Ordering data**
|**DIN colour code**<br>**Strip of wire end ferrules**|**Ordering data**|
|---|---|
||**Type**<br>**ø mm2**<br>**AWG**<br>**L1**<br>**L2**<br>**D1**<br>**D2**<br>**S1**<br>**S2**<br>**Stripping length Colour**<br>**Qty.**<br>**Order No.**|
||H0.5/14D<br>0.50<br>20<br>14.0<br>8.0<br>1.0<br>2.6<br>0.15<br>0.25<br>10.0<br>mwhite<br>T 20A 002 A 500<br>**9004280000**|
||H0.75/14D<br>0.75<br>18<br>14.0<br>8.0<br>1.2<br>2.8<br>0.15<br>0.25<br>10.0<br>l grey<br>T 20A 005 A 500<br>**9004300000**|
||H1.0/14D<br>1.00<br>17<br>14.0<br>8.0<br>1.4<br>3.0<br>0.15<br>0.25<br>10.0<br>l red<br>T 20A 009 A 500<br>**9004330000**|
||H1.5/14D<br>1.50<br>16<br>14.0<br>8.0<br>1.7<br>3.2<br>0.15<br>0.25<br>10.0<br>lblack<br>T 20A 012 A 500<br>**9004350000**|
||H2.5/14D<br>2.50<br>14<br>14.0<br>8.0<br>2.2<br>4.0<br>0.15<br>0.25<br>11.0<br>l blue<br>T 20A 016 A 500<br>**9004360000**|
|||
**J.24**
**Wire end ferrules with plastic collar**
• Polypropylene conical cable entry
**==> picture [133 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
L2<br>L1<br>ø D1<br>ø D2<br>S1<br>S2<br>**----- End of picture text -----**<br>
- Heat-resistant up to 105 °C
- Cable entry made from a not readily flammable material on request
For conductors from 0.5 to 2.5 mm[2] (AWG 20-14) Tin-plated copper Dimensional tolerances to DIN 46228 part 4
**DIN colour code Ordering data Reel of wire end ferrules Type ø mm[[2]]**
**==> picture [368 x 56] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type ø mm [[2]] AWG L1 L2 D1 D2 S1 S2 Stripping length Colour VG* Qty. Order No.<br>H0.5/14D 0.50 20 14.0 8.0 1.0 2.6 0.15 0.25 10.0 m white 5000 9005860000<br>H0.75/14 0.75 18 14.0 8.0 1.2 2.8 0.15 0.25 10.0 l grey 5000 9005870000<br>H1.0/14D 1.00 17 14.0 8.0 1.4 3.0 0.15 0.25 11.0 l red 5000 9005880000<br>H1.5/14D 1.50 16 14.0 8.0 1.7 3.2 0.15 0.25 10.0 l black 5000 9005890000<br>H2.5/14D 2.50 14 14.0 8.0 2.2 4.0 0.15 0.25 11.0 l blue 3000 9005850000<br>**----- End of picture text -----**<br>
**J**
**J.25**
**Wire end ferrules with plastic collar**
## **J**
- Polypropylene conical cable entry
**==> picture [133 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
L2<br>L1<br>ø D1<br>ø D2<br>S1<br>S2<br>**----- End of picture text -----**<br>
- Heat-resistant up to 105 °C
- Cable entry made from a not readily flammable material on request
For conductors from 0.14 to 25 mm[2] (AWG 26-3) Tin-plated copper Dimensional tolerances to DIN 46228 part 4
## **Ordering data**
**other colour code packed loose**
**==> picture [368 x 300] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type ø mm [2] AWG L1 L2 D1 D2 S1 S2 Stripping length Colour Qty. Order No.<br>H0.25/10T 0.25 24 10.0 6.0 0.8 1.8 0.15 0.25 8.0 l yellow 500 9021010000<br>H0.25/12T 0.25 24 12.0 8.0 0.8 1.8 0.15 0.25 10.0 l yellow 500 9021020000<br>H0.5/12D 0.50 20 12.0 6.0 1.0 2.6 0.15 0.25 8.0 m white 500 9019000000<br>H0.5/14D 0.50 20 14.0 8.0 1.0 2.6 0.15 0.25 10.0 m white 500 9019010000<br>H0.5/16D 0.50 20 16.0 10.0 1.0 2.6 0.15 0.25 12.0 m white 500 9019020000<br>H0.75/12T 0.75 18 12.0 6.0 1.2 2.8 0.15 0.25 8.0 l light blue 500 9021030000<br>H0.75/14 0.75 18 14.0 8.0 1.2 2.8 0.15 0.25 10.0 l light blue 500 9021040000<br>H0.75/16T 0.75 18 16.0 10.0 1.2 2.8 0.15 0.25 12.0 l light blue 500 9021050000<br>H0.75/18T 0.75 18 18.0 12.0 1.2 2.8 0.15 0.25 14.0 l light blue 500 9021060000<br>H1.0/12D 1.00 17 12.0 6.0 1.4 3.0 0.15 0.25 8.0 l red 500 9019070000<br>H1.0/14D 1.00 17 14.0 8.0 1.4 3.0 0.15 0.25 10.0 l red 500 9019080000<br>H1.0/16D 1.00 17 16.0 10.0 1.4 3.0 0.15 0.25 12.0 l red 500 9019100000<br>H1.0/18D 1.00 17 18.0 12.0 1.4 3.0 0.15 0.25 15.0 l red 500 9019110000<br>H1.5/14D 1.50 16 14.0 8.0 1.7 3.5 0.15 0.25 10.0 l black 500 9019120000<br>H1.5/16D 1.50 16 16.0 10.0 1.7 3.5 0.15 0.25 12.0 l black 500 9019130000<br>H1.5/18D 1.50 16 18.0 12.0 1.7 3.5 0.15 0.25 15.0 l black 500 9019140000<br>H1.5/24D 1.50 16 24.0 18.0 1.7 3.5 0.15 0.25 20.0 l black 500 9019150000<br>H2.5/14T 2.50 14 14.0 8.0 2.2 4.2 0.15 0.25 10.0 l grey 500 9021070000<br>H2.5/18T 2.50 14 18.0 12.0 2.2 4.2 0.15 0.25 14.0 l grey 500 9021080000<br>H2.5/24T 2.50 14 24.0 18.0 2.2 4.2 0.15 0.25 20.0 l grey 500 9021090000<br>H4.0/17T 4.00 12 17.0 10.0 2.8 4.8 0.2 0.3 12.0 l orange 500 9021100000<br>H4.0/20T 4.00 12 20.0 12.0 2.8 4.8 0.2 0.3 14.0 l orange 500 9021110000<br>H4.0/26T 4.00 12 26.0 18.0 2.8 4.8 0.2 0.3 20.0 l orange 100 9021120000<br>H6.0/20T 6.00 10 20.0 12.0 3.5 6.3 0.2 0.3 14.0 l green 100 9021130000<br>H6.0/26T 6.00 10 26.0 18.0 3.5 6.3 0.2 0.3 20.0 l green 100 9021140000<br>H10.0/22T 10.00 7 22.0 12.0 4.5 7.6 0.2 0.4 15.0 l brown 100 9021150000<br>H10.0/28T 10.00 7 28.0 18.0 4.5 7.6 0.2 0.4 21.0 l brown 100 9021160000<br>H16.0/24T 16.00 6 24.0 12.0 5.8 8.8 0.2 0.4 15.0 m white 100 9021170000<br>H16.0/28T 16.00 6 28.0 18.0 5.8 8.8 0.2 0.4 21.0 m white 100 9021180000<br>H25.0/30T 25.00 3 30.0 16.0 7.3 11.2 0.2 0.4 18.0 l black 50 9021190000<br>H25.0/36T 25.00 3 36.0 22.0 7.3 11.2 0.2 0.4 24.0 l black 50 9021200000<br>**----- End of picture text -----**<br>
## **Ordering data**
**other colour code in multipack bag**
**==> picture [368 x 110] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type ø mm [2] AWG L1 L2 D1 D2 S1 S2 Stripping length Colour Qty. Order No.<br>H0.14/10T 0.14 26 10.0 6.0 0.6 1.5 0.15 0.25 8.0 l brown 500 9028250000<br>H0.25/10T 0.25 24 10.0 6.0 0.8 1.8 0.15 0.25 8.0 l yellow 500 9021210000<br>H0.25/12T 0.25 24 12.0 8.0 0.8 1.8 0.15 0.25 10.0 l yellow 500 9021220000<br>H0.5/14D 0.50 20 14.0 8.0 1.0 2.6 0.15 0.25 10.0 m white 500 9019400000<br>H0.75/14T 0.75 18 14.0 8.0 1.2 2.8 0.15 0.25 10.0 l light blue 500 9021230000<br>H1.0/14D 1.00 17 14.0 8.0 1.4 3.0 0.15 0.25 10.0 l red 500 9019420000<br>H1.5/14D 1.50 16 14.0 8.0 1.7 3.5 0.15 0.25 10.0 l black 500 9019430000<br>H1.5/24D 1.50 16 24.0 18.0 1.7 3.5 0.15 0.25 20.0 l black 500 9004140000<br>H2.5/14T 2.50 14 14.0 8.0 2.2 4.2 0.15 0.25 10.0 l grey 500 9021240000<br>H4.0/17T 4.00 12 17.0 10.0 2.8 4.8 0.2 0.3 12.0 l orange 250 9021250000<br>**----- End of picture text -----**<br>
## **Ordering data**
|**other colour code**<br>**Strip of wire end ferrules**|**Ordering data**<br>**Type**<br>**ø mm2**<br>**AWG**<br>**L1**<br>**L2**<br>**D1**<br>**D2**<br>**S1**<br>**S2**<br>**Stripping length Colour**<br>**Qty.**<br>**Order No.**<br>H0.5/14D<br>0.50<br>20<br>14.0<br>8.0<br>1.0<br>2.6<br>0.15<br>0.25<br>10.0<br>mwhite<br>500<br>**9004280000**<br>H0.75/14T<br>0.75<br>18<br>14.0<br>8.0<br>1.2<br>2.8<br>0.15<br>0.25<br>10.0<br>l light blue<br>500<br>**9004310000**<br>H1.0/14D<br>1.00<br>17<br>14.0<br>8.0<br>1.4<br>3.0<br>0.15<br>0.25<br>10.0<br>l red<br>500<br>**9004330000**<br>H1.5/14D<br>1.50<br>16<br>14.0<br>8.0<br>1.7<br>3.2<br>0.15<br>0.25<br>10.0<br>lblack<br>500<br>**9004350000**<br>H2.5/14T<br>2.50<br>14<br>14.0<br>8.0<br>2.2<br>4.0<br>0.15<br>0.25<br>11.0<br>l grey<br>500<br>**9004370000**|
|---|---|
**J.26**
**Wire end ferrules with plastic collar**
**==> picture [133 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
L2<br>L1<br>ø D1<br>ø D2<br>S1<br>S2<br>**----- End of picture text -----**<br>
**other colour code Reel of wire end ferrules**
• Polypropylene conical cable entry
- Heat-resistant up to 105 °C
- Cable entry made from a not readily flammable material on request
For conductors from 0.5 to 2.5 mm[2] (AWG 20-14) Tin-plated copper Dimensional tolerances to DIN 46228 part 4
## **Ordering data**
**==> picture [368 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type ø mm [2] AWG L1 L2 D1 D2 S1 S2 Stripping length Colour Qty. Order No.<br>H0.5/14D 0.50 20 14.0 8.0 1.0 2.6 0.15 0.25 10.0 m white 5000 9005860000<br>H0.75/14T 0.75 18 14.0 8.0 1.2 2.8 0.15 0.25 10.0 l light blue 5000 9005900000<br>H1.0/14D 1.00 17 14.0 8.0 1.4 3.0 0.15 0.25 11.0 l red 5000 9005880000<br>H1.5/14D 1.50 16 14.0 8.0 1.7 3.2 0.15 0.25 10.0 l black 5000 9005890000<br>H2.5/14T 2.50 14 14.0 8.0 2.2 4.0 0.15 0.25 11.0 l grey 3000 9005910000<br>**----- End of picture text -----**<br>
**J**
**J.27**
**Twin-wire end ferrules with plastic collar**
**J**
**==> picture [113 x 46] intentionally omitted <==**
**----- Start of picture text -----**<br>
B L1<br>L2<br>A<br>D1<br>S1<br>**----- End of picture text -----**<br>
**Weidmüller colour code packed loose**
## **Weidmüller colour code**
**in multipack bag**
**==> picture [8 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
S2<br>**----- End of picture text -----**<br>
- Polypropylene conical cable entry
- Heat-resistant up to 105 °C
- Cable entry made from a not readily flammable material on request
For conductors from 2 x 0,5-2 x 16 mm[2] (2 x AWG 20-2 x AWG 6) Tin-plated copper Dimensional tolerances to DIN 46228 part 4
## **Ordering data**
**==> picture [368 x 417] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type ø mm [2] AWG L1 L2 D1 D2 S1 S2 Stripping length Colour Qty. Order No.<br>H0.5/15 0.50 20 15.0 8.0 1.4 0.15 0.3 11.0 l orange 500 9037200000<br>H0.5/16.5 0.50 20 16.0 10.0 1.4 0.15 0.3 13.0 l orange 500 9037210000<br>H0.5/18.5 0.50 20 19.0 12.0 1.4 0.15 0.3 15.0 l orange 500 9037220000<br>H0.75/15 0.75 18 15.0 8.0 1.7 0.15 0.3 11.0 m white 500 9037230000<br>H0.75/17 0.75 18 17.0 10.0 1.7 0.15 0.3 13.0 m white 500 9037240000<br>H0.75/19S 0.75 18 19.0 12.0 1.4 0.15 0.3 21.0 m white 500 9202820000<br>H0.75/24.5 0.75 18 24.0 18.0 1.7 0.15 0.3 21.0 m white 500 9037250000<br>H1.0/15 1.00 17 15.0 8.0 2.0 0.15 0.3 12.0 l yellow 500 9037260000<br>H1.0/15S 1.00 17 16.0 8.0 2.2 0.15 0.3 12.0 l yellow 500 9018690000<br>H1.0/20 1.00 17 19.0 12.0 2.0 0.15 0.3 16.0 l yellow 500 9037270000<br>H1.0/25.6 1.00 17 25.0 18.0 2.0 0.15 0.3 22.0 l yellow 500 9037280000<br>H1.5/16 1.50 16 16.0 8.2 2.2 0.15 0.3 11.0 l red 500 9037290000<br>H1.5/20 1.50 16 20.0 12.0 2.2 0.15 0.3 15.0 l red 500 9037300000<br>H1.5/25.6 1.50 16 26.0 18.0 2.2 0.15 0.3 21.0 l red 100 9037310000<br>H2.5/18.5D 2.50 14 19.0 10.0 2.8 0.15 0.4 13.0 l blue 500 9037500000<br>H2.5/20.5D 2.50 14 21.0 12.0 2.8 0.15 0.4 15.0 l blue 100 9037510000<br>H2.5/26.5D 2.50 14 27.0 18.0 2.8 0.15 0.4 21.0 l blue 100 9037520000<br>H4.0/22D 4.00 12 22.0 12.0 3.5 0.2 0.5 15.0 l grey 100 9037530000<br>H4.0/28D 4.00 12 28.0 18.0 3.5 0.2 0.5 21.0 l grey 100 9037540000<br>H6.0/25 6.00 10 25.0 12.0 4.5 0.2 0.5 20.0 l black 100 9037320000<br>H6.0/29 6.00 10 29.0 18.0 4.5 0.2 0.5 24.0 l black 100 9037330000<br>H10.0/24S 10.00 7 24.0 12.0 6.5 0.2 0.5 17.0 l ivory 100 9018860000<br>H10.0/26 10.00 7 24.0 12.0 5.8 0.2 0.5 17.0 l ivory 100 9037340000<br>H10.0/30 10.00 7 30.0 18.0 5.8 0.2 0.5 23.0 l ivory 100 9037350000<br>H10.0/30S 10.00 7 30.0 18.0 6.5 0.2 0.5 23.0 l ivory 100 9018870000<br>H16.0/29 16.00 6 29.0 16.0 8.3 0.3 0.6 20.0 l green 50 9037360000<br>H16.0/38 16.00 6 38.0 25.0 8.3 0.3 0.6 29.0 l green 50 9037370000<br>Ordering data<br>Type ø mm [2] AWG L1 L2 D1 D2 S1 S2 Stripping length Colour Qty. Order No.<br>H0.5/15 0.50 20 15.0 8.0 1.4 0.15 0.3 11.0 l orange 500 9004440000<br>H0.75/15 0.75 18 15.0 8.0 1.7 0.15 0.3 11.0 m white 500 9018510000<br>H0.75/17 0.75 18 17.0 10.0 1.7 0.15 0.3 13.0 m white 500 9004900000<br>H1.0/15 1.00 17 15.0 8.0 2.0 0.15 0.3 12.0 l yellow 500 9018530000<br>H1.0/15S 1.00 17 16.0 8.0 2.2 0.15 0.3 12.0 l yellow 500 9018650000<br>H1.0/20 1.00 17 19.0 12.0 2.0 0.15 0.3 16.0 l yellow 500 9004910000<br>H1.5/16 1.50 16 16.0 8.2 2.2 0.15 0.3 11.0 l red 500 9004410000<br>H1.5/20 1.50 16 20.0 12.0 2.2 0.15 0.3 15.0 l red 500 9004920000<br>H2.5/18.5D 2.50 14 19.0 10.0 2.8 0.15 0.4 13.0 l blue 250 9004430000<br>H2.5/20.5D 2.50 14 21.0 12.0 2.8 0.15 0.4 15.0 l blue 250 9004740000<br>H4.0/22D 4.00 12 22.0 12.0 3.5 0.2 0.5 15.0 l grey 100 9004730000<br>H6.0/25 6.00 10 25.0 12.0 4.5 0.2 0.5 20.0 l black 100 9004930000<br>H10.0/26 10.00 7 24.0 12.0 5.8 0.2 0.5 17.0 l ivory 100 9004940000<br>**----- End of picture text -----**<br>
**J.28**
**Twin-wire end ferrules with plastic collar**
**J**
**==> picture [113 x 46] intentionally omitted <==**
**----- Start of picture text -----**<br>
B L1<br>L2<br>A<br>D1<br>S1<br>**----- End of picture text -----**<br>
- Polypropylene conical cable entry
- Heat-resistant up to 105 °C
- Cable entry made from a not readily flammable material on request
For conductors from 2 x 0,5-2 x 16 mm[2] (2 x AWG 20-2 x AWG 6) Tin-plated copper S2 Dimensional tolerances to DIN 46228 part 4
## **Ordering data**
**DIN colour code packed loose**
|**packed loose**<br>**DIN colour code**<br>**in multipack bag**|**Type**<br>**ø mm2**<br>**AWG**<br>**L1**<br>**L2**<br>**D1**<br>**D2**<br>**S1**<br>**S2**<br>**Stripping length Colour**<br>**Qty.**<br>**Order No.**|
|---|---|
||H0.5/15D<br>0.50<br>20<br>15.0<br>8.0<br>1.4<br>0.15<br>0.3<br>11.0<br>mwhite<br>500<br>**9037380000**|
||H0.5/16.5D<br>0.50<br>20<br>16.0<br>10.0<br>1.4<br>0.15<br>0.3<br>13.0<br>mwhite<br>500<br>**9037390000**|
||H0.5/18.4D<br>0.50<br>20<br>19.0<br>12.0<br>1.4<br>0.15<br>0.3<br>15.0<br>mwhite<br>500<br>**9037400000**|
||H0.75/15D<br>0.75<br>18<br>15.0<br>8.0<br>1.7<br>0.15<br>0.3<br>11.0<br>l grey<br>500<br>**9037410000**|
||H0.75/17D<br>0.75<br>18<br>17.0<br>10.0<br>1.7<br>0.15<br>0.3<br>13.0<br>l grey<br>500<br>**9037420000**|
||H0.75/19DS<br>0.75<br>18<br>19.0<br>12.0<br>1.4<br>0.15<br>0.3<br>21.0<br>l grey<br>500<br>**9202830000**|
||H0.75/24.5D<br>0.75<br>18<br>24.0<br>18.0<br>1.7<br>0.15<br>0.3<br>21.0<br>l grey<br>500<br>**9037430000**|
||H1.0/15D<br>1.00<br>17<br>16.0<br>8.0<br>2.2<br>0.15<br>0.3<br>12.0<br>l red<br>500<br>**9037440000**|
||H1.0/20D<br>1.00<br>17<br>19.0<br>12.0<br>2.0<br>0.15<br>0.3<br>16.0<br>l red<br>500<br>**9037450000**|
||H1.0/25.6D<br>1.00<br>17<br>25.0<br>18.0<br>2.0<br>0.15<br>0.3<br>22.0<br>l red<br>500<br>**9037460000**|
||H1.5/16D<br>1.50<br>16<br>16.0<br>8.0<br>2.2<br>0.15<br>0.3<br>11.0<br>lblack<br>500<br>**9037470000**|
||H1.5/20D<br>1.50<br>16<br>20.0<br>12.0<br>2.2<br>0.15<br>0.3<br>15.0<br>lblack<br>500<br>**9037480000**|
||H1.5/25.6D<br>1.50<br>16<br>26.0<br>18.0<br>2.2<br>0.15<br>0.3<br>21.0<br>lblack<br>100<br>**9037490000**|
||H2.5/18.5D<br>2.50<br>14<br>19.0<br>10.0<br>2.8<br>0.15<br>0.4<br>13.0<br>l blue<br>500<br>**9037500000**|
||H2.5/20.5D<br>2.50<br>14<br>21.0<br>12.0<br>2.8<br>0.15<br>0.4<br>15.0<br>l blue<br>100<br>**9037510000**|
||H2.5/26.5D<br>2.50<br>14<br>27.0<br>18.0<br>2.8<br>0.15<br>0.4<br>21.0<br>l blue<br>100<br>**9037520000**|
||H4.0/22D<br>4.00<br>12<br>22.0<br>12.0<br>3.5<br>0.2<br>0.5<br>15.0<br>l grey<br>100<br>**9037530000**|
||H4.0/28D<br>4.00<br>12<br>28.0<br>18.0<br>3.5<br>0.2<br>0.5<br>21.0<br>l grey<br>100<br>**9037540000**|
||H6.0/25D<br>6.00<br>10<br>25.0<br>12.0<br>4.5<br>0.2<br>0.5<br>20.0<br>l yellow<br>100<br>**9037550000**|
||H6.0/29D<br>6.00<br>10<br>29.0<br>18.0<br>4.5<br>0.2<br>0.5<br>24.0<br>l yellow<br>100<br>**9037560000**|
||H10.0/24DS<br>10.00<br>7<br>24.0<br>12.0<br>6.5<br>0.2<br>0.5<br>17.0<br>l red<br>100<br>**9018880000**|
||H10.0/26D<br>10.00<br>7<br>24.0<br>12.0<br>5.8<br>0.2<br>0.5<br>17.0<br>l red<br>100<br>**9037570000**|
||H10.0/30D<br>10.00<br>7<br>30.0<br>18.0<br>5.8<br>0.2<br>0.5<br>23.0<br>l red<br>100<br>**9037580000**|
||H10.0/30DS<br>10.00<br>7<br>30.0<br>18.0<br>6.5<br>0.2<br>0.5<br>23.0<br>l red<br>100<br>**9018890000**|
||H16.0/29D<br>16.00<br>6<br>29.0<br>16.0<br>8.3<br>0.3<br>0.6<br>20.0<br>l blue<br>50<br>**9037590000**|
||H16.0/38D<br>16.00<br>6<br>38.0<br>25.0<br>8.3<br>0.3<br>0.6<br>29.0<br>l blue<br>50<br>**9037600000**|
|||
||**Ordering data**|
||**Type**<br>**ø mm2**<br>**AWG**<br>**L1**<br>**L2**<br>**D1**<br>**D2**<br>**S1**<br>**S2**<br>**Stripping length Colour**<br>**Qty.**<br>**Order No.**|
||H0.5/15D<br>0.50<br>20<br>15.0<br>8.0<br>1.4<br>0.15<br>0.3<br>11.0<br>mwhite<br>500<br>**9004780000**|
||H0.75/15D<br>0.75<br>18<br>15.0<br>8.0<br>1.7<br>0.15<br>0.3<br>11.0<br>l grey<br>500<br>**9018520000**|
||H0.75/17D<br>0.75<br>18<br>17.0<br>10.0<br>1.7<br>0.15<br>0.3<br>13.0<br>l grey<br>500<br>**9004770000**|
||H1.0/15D<br>1.00<br>17<br>16.0<br>8.0<br>2.2<br>0.15<br>0.3<br>12.0<br>l red<br>500<br>**9018540000**|
||H1.0/20D<br>1.00<br>17<br>19.0<br>12.0<br>2.0<br>0.15<br>0.3<br>16.0<br>l red<br>500<br>**9004760000**|
||H1.5/16D<br>1.50<br>16<br>16.0<br>8.0<br>2.2<br>0.15<br>0.3<br>11.0<br>lblack<br>500<br>**9004420000**|
||H1.5/20D<br>1.50<br>16<br>20.0<br>12.0<br>2.2<br>0.15<br>0.3<br>15.0<br>lblack<br>500<br>**9004750000**|
||H2.5/18.5D<br>2.50<br>14<br>19.0<br>10.0<br>2.8<br>0.15<br>0.4<br>13.0<br>l blue<br>250<br>**9004430000**|
||H2.5/20.5D<br>2.50<br>14<br>21.0<br>12.0<br>2.8<br>0.15<br>0.4<br>15.0<br>l blue<br>250<br>**9004740000**|
||H4.0/22D<br>4.00<br>12<br>22.0<br>12.0<br>3.5<br>0.2<br>0.5<br>15.0<br>l grey<br>100<br>**9004730000**|
||H6.0/25D<br>6.00<br>10<br>25.0<br>12.0<br>4.5<br>0.2<br>0.5<br>20.0<br>l yellow<br>100<br>**9004720000**|
||H10.0/26D<br>10.00<br>7<br>24.0<br>12.0<br>5.8<br>0.2<br>0.5<br>17.0<br>l red<br>100<br>**9004710000**|
|||
**J.29**
**Twin-wire end ferrules with plastic collar**
**J**
**==> picture [113 x 46] intentionally omitted <==**
**----- Start of picture text -----**<br>
B L1<br>L2<br>A<br>D1<br>S1<br>**----- End of picture text -----**<br>
**other colour code packed loose**
## **other colour code**
**in multipack bag**
**==> picture [8 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
S2<br>**----- End of picture text -----**<br>
- Polypropylene conical cable entry
- Heat-resistant up to 105 °C
- Cable entry made from a not readily flammable material on request
For conductors from 2 x 0,5-2 x 16 mm[2] (2 x AWG 20-2 x AWG 6) Tin-plated copper Dimensional tolerances to DIN 46228 part 4
## **Ordering data**
**==> picture [368 x 237] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type ø mm [2] AWG L1 L2 D1 D2 S1 S2 Stripping length Colour Qty. Order No.<br>H0.5/15 0.50 20 15.0 8.0 1.4 0.15 0.3 11.0 l orange 500 9037200000<br>H0.5/16.5 0.50 20 16.0 10.0 1.4 0.15 0.3 13.0 l orange 500 9037210000<br>H0.5/18.5 0.50 20 19.0 12.0 1.4 0.15 0.3 15.0 l orange 500 9037220000<br>H0.75/15T 0.75 18 15.0 8.0 1.7 0.15 0.3 11.0 l light blue 500 9037610000<br>H0.75/17T 0.75 18 17.0 10.0 1.7 0.15 0.3 13.0 l light blue 500 9037620000<br>H0.75/19TS 0.75 18 19.0 12.0 1.4 0.15 0.3 21.0 l light blue 500 9202840000<br>H0.75/24.5T 0.75 18 24.0 18.0 1.7 0.15 0.3 21.0 l light blue 500 9037630000<br>H1.0/15D 1.00 17 16.0 8.0 2.2 0.15 0.3 12.0 l red 500 9037440000<br>H1.0/20D 1.00 17 19.0 12.0 2.0 0.15 0.3 16.0 l red 500 9037450000<br>H1.0/25.6D 1.00 17 25.0 18.0 2.0 0.15 0.3 22.0 l red 500 9037460000<br>H1.5/16D 1.50 16 16.0 8.0 2.2 0.15 0.3 11.0 l black 500 9037470000<br>H1.5/20D 1.50 16 20.0 12.0 2.2 0.15 0.3 15.0 l black 500 9037480000<br>H1.5/25.6D 1.50 16 26.0 18.0 2.2 0.15 0.3 21.0 l black 100 9037490000<br>H2.5/18.5T 2.50 14 19.0 10.0 2.8 0.15 0.4 13.0 l grey 500 9037640000<br>H2.5/20.5T 2.50 14 21.0 12.0 2.8 0.15 0.4 15.0 l grey 100 9037650000<br>H2.5/26.5T 2.50 14 27.0 18.0 2.8 0.15 0.4 21.0 l grey 100 9037660000<br>H4.0/22T 4.00 12 22.0 12.0 3.5 0.2 0.5 15.0 l orange 100 9037670000<br>H4.0/28T 4.00 12 28.0 18.0 3.5 0.2 0.5 21.0 l orange 100 9037680000<br>H6.0/25T 6.00 10 25.0 12.0 4.5 0.2 0.5 20.0 l green 100 9037690000<br>H6.0/29T 6.00 10 29.0 18.0 4.5 0.2 0.5 24.0 l green 100 9037700000<br>H10.0/26T 10.00 7 24.0 12.0 5.8 0.2 0.5 17.0 l brown 100 9037710000<br>H10.0/30T 10.00 7 30.0 18.0 5.8 0.2 0.5 23.0 l brown 100 9037720000<br>H16.0/19T 16.00 6 29.0 16.0 8.3 0.3 0.6 20.0 m white 50 9037730000<br>H16.0/38T 16.00 6 38.0 25.0 8.3 0.3 0.6 29.0 m white 50 9037740000<br>**----- End of picture text -----**<br>
## **Ordering data**
**==> picture [368 x 110] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type ø mm [2] AWG L1 L2 D1 D2 S1 S2 Stripping length Colour Qty. Order No.<br>H0.75/17T 0.75 18 17.0 10.0 1.7 0.15 0.3 13.0 l light blue 500 9005140000<br>H1.0/15D 1.00 17 16.0 8.0 2.2 0.15 0.3 12.0 l red 500 9018540000<br>H1.0/20D 1.00 17 19.0 12.0 2.0 0.15 0.3 16.0 l red 500 9004760000<br>H1.5/16D 1.50 16 16.0 8.0 2.2 0.15 0.3 11.0 l black 500 9004420000<br>H1.5/20D 1.50 16 20.0 12.0 2.2 0.15 0.3 15.0 l black 500 9004750000<br>H2.5/18.5T 2.50 14 19.0 10.0 2.8 0.15 0.4 13.0 l grey 250 9018580000<br>H2.5/20.5 2.50 14 21.0 12.0 2.8 0.15 0.4 15.0 l grey 250 9005150000<br>H4.0/22T 4.00 12 22.0 12.0 3.5 0.2 0.5 15.0 l orange 100 9018590000<br>H6.0/25T 6.00 10 25.0 12.0 4.5 0.2 0.5 20.0 l green 100 9005160000<br>H10.0/26T 10.00 7 24.0 12.0 5.8 0.2 0.5 17.0 l brown 100 9005170000<br>**----- End of picture text -----**<br>
**J.30**
**Wire end ferrules for short-circuit and earth-fault-proof cables**
- Polypropylene conical cable entry
**==> picture [297 x 58] intentionally omitted <==**
**----- Start of picture text -----**<br>
L2<br>• Heat-resistant up to 105 °C<br>For conductors from 1.5 to 16 mm [2] (AWG 16-6)<br>L1 Tin-plated copper<br>Dimensional tolerances to DIN 46228 part 4<br>ø D1<br>ø D2<br>S1<br>S2<br>**----- End of picture text -----**<br>
- Cable entry made from a not readily flammable material on request
## **Ordering data**
**Weidmüller colour code packed loose**
|**Weidmüller colour code**|**Ordering data**|
|---|---|
|**packed loose**<br>**Weidmüller colour code**<br>**in multipack bag**|**Type**<br>**ø mm2**<br>**AWG**<br>**L1**<br>**L2**<br>**D1**<br>**D2**<br>**S1**<br>**S2**<br>**Stripping length Colour**<br>**Qty.**<br>**Order No.**|
||H1.5/24 XS<br>1.50<br>16<br>24.0<br>18.0<br>1.8<br>6.8<br>0.15<br>0.3<br>20.0<br>lblack<br>100<br>**9202870000**|
||H2.5/24 XS<br>2.50<br>14<br>24.0<br>18.0<br>2.3<br>7.6<br>0.15<br>0.3<br>20.0<br>l blue<br>100<br>**9202880000**|
|||
||**Ordering data**|
||**Type**<br>**ø mm2**<br>**AWG**<br>**L1**<br>**L2**<br>**D1**<br>**D2**<br>**S1**<br>**S2**<br>**Stripping length Colour**<br>**Qty.**<br>**Order No.**|
||H1.5/17.5X<br>1.50<br>16<br>17.5<br>8.0<br>1.8<br>6.8<br>0.15<br>0.3<br>13.0<br>lblack<br>100<br>**9006590000**|
||H1.5/19.5X<br>1.50<br>16<br>19.5<br>10.0<br>1.8<br>6.8<br>0.15<br>0.3<br>15.0<br>lblack<br>100<br>**9006630000**|
||H2.5/17.5X<br>2.50<br>14<br>17.5<br>8.0<br>2.3<br>7.6<br>0.15<br>0.3<br>14.0<br>l blue<br>100<br>**9006670000**|
||H2.5/21.5X<br>2.50<br>14<br>21.5<br>12.0<br>2.3<br>7.6<br>0.15<br>0.3<br>17.0<br>l blue<br>100<br>**9006710000**|
||H4.0/19.5X<br>4.00<br>12<br>19.5<br>10.0<br>2.9<br>7.8<br>0.2<br>0.3<br>14.0<br>l grey<br>100<br>**9006750000**|
||H6.0/23.0X<br>6.00<br>10<br>23.0<br>12.0<br>3.6<br>8.1<br>0.2<br>0.3<br>17.0<br>l yellow<br>100<br>**9006790000**|
||H10.0/24.5X<br>10.00<br>7<br>24.0<br>12.0<br>4.6<br>9.6<br>0.2<br>0.3<br>17.0<br>l red<br>100<br>**9006830000**|
||H16.0/25.5X<br>16.00<br>6<br>25.5<br>12.0<br>6.0<br>11.9<br>0.2<br>0.3<br>26.0<br>l blue<br>100<br>**9006870000**|
|||
**J**
**J.31**
**Wire end ferrules with plastic collar, special sizes**
**==> picture [133 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
L2<br>L1<br>ø D1<br>ø D2<br>S1<br>S2<br>**----- End of picture text -----**<br>
- Polypropylene conical cable entry
- Heat-resistant up to 105 °C
- Cable entry made from a not readily flammable material on request
For conductors from 0.5 to 2.5 mm[2] (AWG 20-14) Tin-plated copper Dimensional tolerances to DIN 46228 part 4
|**Weidmüller colour code**<br>**packed loose**<br>**Weidmüller colour code**<br>**in multipack bag**|**Ordering data**|
|---|---|
||**Type**<br>**ø mm2**<br>**AWG**<br>**L1**<br>**L2**<br>**D1**<br>**D2**<br>**S1**<br>**S2**<br>**Stripping length Colour**<br>**Qty.**<br>**Order No.**|
||H0.5/14S<br>0.50<br>20<br>14.0<br>8.0<br>1.0<br>2.9<br>0.15<br>0.25<br>10.0<br>l orange<br>500<br>**9004560000**|
||H0.5/14S<br>0.50<br>20<br>14.0<br>8.0<br>1.0<br>2.9<br>0.15<br>0.25<br>10.0<br>mwhite<br>500<br>**9004590000**|
||H0.5/16DS<br>0.50<br>20<br>16.0<br>10.0<br>1.0<br>2.9<br>0.15<br>0.25<br>12.0<br>mwhite<br>500<br>**9202910000**|
||H0.5/16S<br>0.50<br>20<br>16.0<br>10.0<br>1.0<br>2.9<br>0.15<br>0.25<br>12.0<br>l orange<br>500<br>**9202900000**|
||H0.75/14S<br>0.75<br>18<br>14.0<br>8.0<br>1.2<br>3.4<br>0.15<br>0.25<br>10.0<br>mwhite<br>500<br>**9025960000**|
||H0.75/14TS<br>0.75<br>18<br>14.0<br>8.0<br>1.2<br>3.4<br>0.15<br>0.25<br>10.0<br>l light blue<br>500<br>**9018550000**|
||H1.0/14S<br>1.00<br>17<br>14.0<br>8.0<br>1.4<br>3.5<br>0.15<br>0.25<br>10.0<br>l yellow<br>500<br>**9025970000**|
||H1.0/14S<br>1.00<br>17<br>14.0<br>8.0<br>1.4<br>3.5<br>0.15<br>0.25<br>10.0<br>l red<br>500<br>**9018560000**|
||H1.5/12S<br>1.50<br>16<br>12.0<br>6.0<br>1.7<br>3.5<br>0.15<br>0.25<br>8.0<br>l red<br>500<br>**9025690000**|
||H1.5/14S<br>1.50<br>16<br>14.0<br>8.0<br>1.7<br>3.9<br>0.15<br>0.25<br>10.0<br>l red<br>500<br>**9025980000**|
||H1.5/14S<br>1.50<br>16<br>14.0<br>8.0<br>1.7<br>3.9<br>0.15<br>0.25<br>10.0<br>lblack<br>500<br>**9025240000**|
||H2.5/12DS<br>2.50<br>14<br>12.0<br>6.0<br>2.2<br>4.2<br>0.15<br>0.25<br>8.0<br>l blue<br>500<br>**9028490000**|
||H2.5/12TS<br>2.50<br>14<br>12.0<br>6.0<br>2.2<br>4.2<br>0.15<br>0.25<br>8.0<br>l grey<br>500<br>**9036200000**|
||H2.5/14S<br>2.50<br>14<br>14.0<br>8.0<br>2.2<br>4.0<br>0.15<br>0.25<br>10.0<br>l blue<br>500<br>**1333100000**|
||H2.5/14TS<br>2.50<br>14<br>14.0<br>8.0<br>2.2<br>4.0<br>0.15<br>0.25<br>10.0<br>l grey<br>500<br>**9426770000**|
||H2.5/16DS<br>2.50<br>14<br>16.0<br>10.0<br>2.2<br>4.2<br>0.15<br>0.25<br>13.0<br>l blue<br>500<br>**9036220000**|
|||
||**Ordering data**|
||**Type**<br>**ø mm2**<br>**AWG**<br>**L1**<br>**L2**<br>**D1**<br>**D2**<br>**S1**<br>**S2**<br>**Stripping length Colour**<br>**Qty.**<br>**Order No.**|
||H0.75/14S<br>0.75<br>18<br>14.0<br>8.0<br>1.2<br>3.4<br>0.15<br>0.25<br>10.0<br>mwhite<br>500<br>**9025700000**|
||H1.0/14S<br>1.00<br>17<br>14.0<br>8.0<br>1.4<br>3.5<br>0.15<br>0.25<br>10.0<br>l yellow<br>500<br>**9025710000**|
||H1.5/14DS<br>1.50<br>16<br>14.0<br>8.0<br>1.7<br>3.9<br>0.15<br>0.25<br>10.0<br>lblack<br>500<br>**9028360000**|
||H1.5/14S<br>1.50<br>16<br>14.0<br>8.0<br>1.7<br>3.9<br>0.15<br>0.25<br>10.0<br>l red<br>500<br>**9025720000**|
|||
**J**
**J.32**
**Wire end ferrules without plastic collar**
**J**
For conductors 0.25-185 mm[2] (AWG 24-350MCM) Material: tin-plated copper Dimensional tolerances to DIN 46228 part 1
**without plastic collar packed loose**
## **Ordering data**
**==> picture [358 x 446] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Type|ø mm|[2]|AWG|L1|L2|D1|D2|S1|S2|Stripping length|Colour|Qty.|Order No.|
|H0.25/5|0.25|24|5.0|0.7|1.6|5.0|1000|9018910000|
|H0.5/10|0.50|20|10.0|1.0|2.1|10.0|1000|9004050000|
|H0.5/6|0.50|20|6.0|1.0|2.1|6.0|1000|0282600000|
|H0.75/10|0.75|18|10.0|1.2|2.3|10.0|1000|0542500000|
|H0.75/6|0.75|18|6.0|1.2|2.3|6.0|1000|0282700000|
|H1.0/10|1.00|17|10.0|1.4|2.5|10.0|1000|0282800000|
|H1.0/6|1.00|17|6.0|1.4|2.5|6.0|1000|0372600000|
|H1.5/7|1.50|16|7.0|1.7|2.8|7.0|1000|0372700000|
|H1.5/10|1.50|16|10.0|1.7|2.8|10.0|1000|0186500000|
|H1.5/12|1.50|16|12.0|1.7|2.8|12.0|1000|9004060000|
|H1.5/18|1.50|16|18.0|1.7|2.8|18.0|1000|9004070000|
|H2.5/7|2.50|14|7.0|2.2|3.4|7.0|1000|0373000000|
|H2.5/10|2.50|14|10.0|2.2|3.4|10.0|1000|9004080000|
|H2.5/12|2.50|14|12.0|2.2|3.4|12.0|1000|0186100000|
|H2.5/18|2.50|14|18.0|2.2|3.4|18.0|1000|9004090000|
|H4.0/9|4.00|12|9.0|2.8|4.0|9.0|500|0373100000|
|H4.0/15|4.00|12|15.0|2.8|4.0|15.0|500|9004100000|
|H4.0/12|4.00|12|12.0|2.8|4.0|12.0|1000|0244100000|
|H4.0/18|4.00|12|18.0|2.8|4.0|18.0|500|9004110000|
|H6.0/10|6.00|10|10.0|3.5|4.7|10.0|500|9004120000|
|H6.0/12|6.00|10|12.0|3.5|4.7|12.0|500|0191900000|
|H6.0/15|6.00|10|15.0|3.5|4.7|15.0|500|0124700000|
|H6.0/18|6.00|10|18.0|3.5|4.7|18.0|500|9004130000|
|H10.0/12|10.00|7|12.0|4.5|5.8|12.0|500|0282900000|
|H10.0/15|10.00|7|15.0|4.5|5.8|15.0|500|0124800000|
|H10.0/18|10.00|7|18.0|4.5|5.8|18.0|500|0379300000|
|H16.0/12|16.00|6|12.0|5.8|7.5|12.0|500|0492500000|
|H16.0/15|16.00|6|15.0|5.8|7.5|15.0|500|0124300000|
|H16.0/18|16.00|6|18.0|5.8|7.5|18.0|100|0375200000|
|H16.0/25|16.00|6|25.0|5.8|7.5|25.0|100|9004150000|
|H16.0/32|16.00|6|32.0|5.8|7.5|32.0|100|9004160000|
|H25.0/15|25.00|3|15.0|7.3|9.5|15.0|250|0124400000|
|H25.0/18|25.00|3|18.0|7.3|9.5|18.0|100|0375300000|
|H25.0/25|25.00|3|25.0|7.3|9.5|25.0|250|9004170000|
|H25.0/32|25.00|3|32.0|7.3|9.5|32.0|100|9004180000|
|H35.0/18|35.00|2|18.0|8.3|11.0|18.0|100|0368900000|
|H35.0/25|35.00|2|25.0|8.3|11.0|25.0|100|9004190000|
|H35.0/30|35.00|2|30.0|8.3|11.0|30.0|100|9451000000|
|H35.0/32|35.00|2|32.0|8.3|11.0|32.0|100|9004200000|
|H50.0/18|50.00|1|18.0|10.3|13.0|18.0|100|9004210000|
|H50.0/25|50.00|1|25.0|10.3|13.0|25.0|100|9025880000|
|H50.0/32|50.00|1|32.0|10.3|13.0|32.0|100|9004220000|
|H70.0/25|70.00|2/0|25.0|12.5|15.0|25.0|50|9004230000|
|H70.0/32|70.00|2/0|32.0|12.5|15.0|32.0|50|9004240000|
|H95.0/25|95.00|3/0|25.0|14.5|17.0|25.0|50|9004250000|
|H95.0/32|95.00|3/0|32.0|14.5|17.0|32.0|50|9004260000|
|H120.0/32|120.00|4/0|32.0|16.5|19.0|32.0|25|9036240000|
|H150.0/32|150.00|300 MCM|32.0|18.5|21.0|32.0|25|9036250000|
|H185.0/32|185.00|350 MCM|32.0|20.0|23.5|32.0|25|9036260000|
**----- End of picture text -----**<br>
**J.33**
**J**
**J.34**
**Tools for insulated cable lugs and ferrules**
**J**
## **Tools**
## **Tools for insulated cable lugs**
**==> picture [512 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
Tool Type of contact<br>Order No. 0.5 - 1.5 1.5 - 2.5 4.0 - 6.0<br>CTI 6 9006120000 l l l<br>CTI 6 S 9006210000 l l l<br>HTI 15 9014400000 l l<br>Station red blue yellow<br>**----- End of picture text -----**<br>
## **Crimping tools for ferrules**
**==> picture [512 x 52] intentionally omitted <==**
**----- Start of picture text -----**<br>
PZ 1.5 stripax [®] PZ 3 PZ 4 PZ 6 PZ 6 HEX PZ 6/5 PZ 16 PZ 50<br>plus 2.5 roto<br>Order No.<br>9005990000 9020000000 0567300000 9012500000 9014350000 9013650000 9011460000 9012600000 9006450000<br>[2]<br>**----- End of picture text -----**<br>
||**9005990000**|**9020000000**|**0567300000**|**9012500000**|**9014350000**|**9013650000**|**9011460000**|**9012600000**|**9006450000**|
|---|---|---|---|---|---|---|---|---|---|
|**Ferrule mm2**||||||||||
|||||||||||
|H 0.25|l||||l|l|l|||
|H 0.34|l||||l|l|l|||
|H 0.5|l|l1|l|l|l|l|l|||
|H 0.75|l|l1|l|l|l|l|l|||
|H 1.0|l|l1|l|l|l|l|l|||
|H 1.5|l|l1|l|l|l|l|l|||
|H 2.5||l1|l|l|l|l|l|||
|H 4.0|||l|l|l|l|l|||
|H 6.0|||l||l|l|l|l||
|H 10.0||||||||l||
|H 16.0||||||||l||
|H 25.0|||||||||l|
|H 35.0|||||||||l|
|H 50.0|||||||||l|
|||||||||||
l[1] = ferrules in strip form only
## **Twin wire end ferrules are to be crimped according to the following table:**
**==> picture [513 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
Tool Ferrules<br>Order No. H 0.5 H 0.75 H 1.0 H 1.5 H 2.5 H 4.0 H 6.0 H 10.0 H 16.0<br>PZ 1.5 9005990000 l l<br>PZ 3 0567300000 l l l l l<br>PZ 4 9012500000 l l l l l<br>PZ 6 roto 9014350000 l l l l l l<br>PZ 6/5 9011460000 l l l l l<br>Station 1.5 mm [2] 1.5 mm [2] 2.5 mm [2] 2.5 mm [2] 4 mm [2] 6 mm [2]<br>PZ ZH 16 9013600000 l l l<br>**----- End of picture text -----**<br>
**J.35**
**J**
**J.36**
**Contents**
## Technical appendix
## **Technical appendix**
|**Certificates**|W.2|
|---|---|
|**Electrical data**||
|Insulating materials|W.4|
|Design of clearences and creepage distances in electrical equipment – influencing factors|W.6|
|**General technical information**||
|IP class of protection to DIN EN 60529|W.8|
|Conversion table for AWG to mm² conductors|W.9|
|**Installation instructions**||
|Connecting the terminals|W.10|
|The use of aluminium conductors|W.11|
|**Connection system**||
|Free choice of connection technology|W.12|
|**Terminals**||
|Regulations / definitions|W.14|
|The assembly of terminals rails|W.15|
|**Definitions of the various terminal types**|W.16|
|**ATEX**||
|ATEX terminals|W.18|
|ATEX directives|W.20|
|ATEX codes|W.21|
|ATEX cross-connection instructions|W.22|
**W**
**W.1**
**Materials**
## Insulating materials
In order to always deliver to you first-class products, quality control is of the utmost importance to us. Beginning with our product quality management under ISO 9000 ff., and extending to the continuous monitoring by independent institutes. These control our production facilities, our quality management and our own laboratory. And so we benefit from total reliability and longevity!
## **Accredited testing laboratories**
The reliability of the technical data is of the utmost importance to the user. Our lab has DIN EN ISO/IEC accreditations from an external independent institution (the German Accreditation Body for Technology GmbH). This enables our lab to carry out certified tests for terminal blocks, connectors, and electronic equipment – including EMC and environmental impact tests. And so you can be sure that our products can be used throughout the world.
**W** ~~7~~ .
**W.2**
**Materials**
**W**
## **Product approvals**
Approvals are proof of the quality of our products. The appro vals are granted following performance tests carried out by independent institutions, and are the prerequisite for product use in certain markets or fields of applications.
## **Certifications**
Quality management in the Weidmüller group of companies is based on ISO 9000 ff. Certified verification by accredited certification bodies makes it easier for you to judge suppliers.
## **ATEX**
**W.3**
**Electrical data**
## Insulating materials
**W**
In order to do justice to the most diverse requirements placed on our products, it is necessary to use different insulating materials tailored to the needs of the applications. None of the insulating materials used by Weidmüller contain any hazardous substances. Above all, the use of cadium-free materials is very high on our agenda. Furthermore, our insulating materials contain neither pigments based on heavy metals nor any substances that lead to the formation of dioxin or furan.
## ~~**Ceramics**~~
## ~~**Thermosetting plastics**~~
## ~~**Plastic Ceramics Abbreviation**~~
## ~~**Gemin Epoxy resin KrG EP**~~
Ceramics are excellent materials for electrical engineering because they fulfil all the requirements. Ceramics are resistant to heat, fluids and sparks, and are tested for leakage currents. Thanks to their high mechanical strength, low losses and good heat resistance, these materials have a very high chemical stability and are preferred because of their very low wear. Insulating material
Thermosetting plastics exhibit high dimensional stability, low water absorption, extremely good tracking resistance and excellent fire resistance.
The continuous operating temperatures are higher than those of thermoplastics. At higher thermal loads the deformation resistance of thermosetting plastics is better than that of thermoplastics.
The disadvantage in comparison with thermoplastics is the reduced flexibility of thermosetting plastics.
||~~**Colour**~~<br>~~**Description**~~<br>~~**Properties**~~<br>Specific volume resistance to IEC 60093<br>Ω x cm<br>Electric strength to IEC 60243-1<br>kV / mm<br>Trackingresistance(A)to IEC 60112<br>CTI<br>Upper max.permissible temperature<br>°C<br>Lower max.permissible temperature, static<br>°C<br>Flamabilityclass to UL 94<br>Fire behaviour to railwaystandard|Melamine resin moulding<br>compound, MF type 150<br>(DIN EN ISO 14 528)<br>inorganic filler<br>~~**medium yellow**~~<br>high continuous operating<br>temperature<br>high fire resistance<br>high tracking resistance<br>inherently flame-retardant<br>halogen-free<br>flame-retardant agent<br>1011<br>10<br>≥ 600<br>130<br>–60<br>V-0(5 V-A)<br>Epoxy resin with<br>inorganic filler<br>~~**black**~~<br>very good electrical<br>properties<br>very high continuous<br>operating temperature<br>resistant to high-energy<br>radiation<br>halogen- and phosphor-free<br>flame-retardant agent<br>1014<br>160<br>≥ 600<br>160<br>–60<br>V-0<br>Insulating material<br>~~**white**~~<br>highest continuous<br>operating temperature<br>high fire resistance<br>fluids-repellent<br>high tracking resistance<br>inherently flame-retardant<br>-<br>>10<br>≥ 600<br>250<br>–60<br>V-0(5 V-B)|
|---|---|---|
**W.4**
**Electrical data**
## ~~**Thermoplastics**~~
|~~**Wemid**~~<br>**Wemid**is a modified thermo-<br>plastic whose properties have<br>been specially devised to<br>suit the requirements of<br>Weidmüller connectors.<br>The advantages in compari-<br>son with PA are the better<br>fire protection and the higher<br>continuous operating tem-pe-<br>rature.<br>Wemid fulfils the strict<br>requirements placed on<br>applications for railway rolling<br>stock to NF F 16-101.<br>special Weidmüller<br>insulating material<br>~~**dark beige**~~<br>~~**Polyamide**~~<br>~~**PA**~~<br>**Polyamide (PA)**is one of the<br>most common commercial<br>plastics. The advantages of<br>this material are its very good<br>electrical and mechanical pro-<br>perties, its flexibility and resi-<br>stance to breakage.<br>Furthermore, owing to its<br>chemical structure PA achie-<br>ves good fire resistance even<br>without the use of flame-re-<br>tardant agents.<br>insulating material<br>~~**beige**~~|~~**Polyamide**~~<br>~~**PAGF**~~<br>**Glass fibre-reinforced**<br>**polyamide (PAGF)**<br>offers excellent dimensional<br>stability and very good<br>mechanical properties.<br>That makes this material ideal<br>for use in end brackets.<br>Compared with unreinforced<br>PA, this material can achieve<br>UL 94 flammability class HB.<br>insulating material<br>~~**beige**~~<br>excellent dimensional<br>stability<br>very good mechanical<br>properties<br>halogen-free<br>flame-retardant agent<br>1012<br>30<br>500<br>100<br>–50<br>HB<br>~~**Polybutylene-**~~<br>~~**terephthalate PBT**~~<br>**This thermoplastic**<br>**polyester (PBT)**<br>offers excellent dimensional<br>stability (and is therefore ideal<br>for plug-in connectors) and a<br>high continuous operation<br>temperature.<br>But the tracking resistance is<br>lower than other insulating<br>materials.<br>with or without glass fibre<br>reinforcement depending on<br>application<br>~~**orange**~~<br>high dimensional<br>stability<br>good electrical and<br>mechanical properties<br>flame-retardant substances<br>do not lead to the formation<br>of dioxin or furan<br>1013<br>28<br>200<br>115 / 130<br>–50<br>V-0<br>~~**Polycarbonate**~~<br>~~**PC**~~<br>with or without glass fibre<br>reinforcement depending on<br>application<br>~~**grey**~~<br>high dimensional<br>stability<br>high continuous<br>operating temperature<br>high electrical<br>insulation capacity<br>halogen-free<br>flame-retardant agent<br>1016<br>≥ 30<br>≥ 175<br>115 / 125<br>–50<br>V-2 / V-0<br>I2 / F2|
|---|---|
|||
|higher continuous operating<br>temperature<br>improved fire resistance<br>halogen- and phosphor-free<br>flame-retardant agent<br>flame-retardant agent low<br>smoke development in fire<br>certified for railway applica-<br>tions to NF F 16-101<br>1012<br>25<br>600<br>120<br>–50<br>V-0<br>I2 / F2 *)<br>~~*) also certified to~~<br>~~LUL E 1042~~<br>flexible, virtually unbreakable<br>good electrical and<br>mechanical properties<br>self-extinguishing<br>behaviour<br>halogen-free<br>flame-retardant agent<br>1012<br>30<br>600<br>100<br>–50<br>V-2||
**W**
**W.5**
**Electrical data**
## Design of clearances and creepage distances in electrical equipment – influencing factors
**W**
## **Rated impulse withstand voltage**
The rated impulse withstand voltage is derived from:
- **Voltage conductor – earth**
- (the rated voltage of the network, taking into account all networks)
- **Surge category**
**Table 1: Rated impulse withstand voltages for electrical equipment**
|Rated voltage of power<br>supplies system *) in V|Rated voltage of power<br>supplies system *) in V|Rated impulse withstand voltage in kV|Rated impulse withstand voltage in kV|Rated impulse withstand voltage in kV|Rated impulse withstand voltage in kV|
|---|---|---|---|---|---|
|Three-phase<br>systems|Single-phase<br>systems with<br>neutral point|Electrical equipment<br>at the supplies point<br>of the installation<br>**(Surge**<br>**category IV)**|Electrical equipment<br>as part of the<br>permanent<br>installation<br>**(Surge**<br>**category III)**|Electrical equipment<br>to be connected to<br>the permanent<br>installation<br>**(Surge**<br>**category II)**|Specially protected<br>electrical equipment<br>**(Surge**<br>**category I)**|
||120 to 240|4.00|2.50|1.50|0.80|
|230/400<br>277/480||6.00|4.00|2.50|1.50|
|400/690||8.00|6.00|4.00|2.50|
|1000||Values depend on the particular project of, if no values are available, the values of the<br>preceding line apply.||||
|*)to IEC 38||||||
## **Surge categories**
## **Surge category III**
are stipulated in accordance with the German standard DIN VDE 0110-1 (for electrical equipment fed directly from the low-voltage network).
- Equipment that is part of the permanent electrical installation and other equipment where a higher degree of availability is expected, e.g. distribution boards, circuit-breakers, wiring systems (including cables, busbars, junction boxes, switches, power sockets) in the permanent installation, and equipment for industrial use and some other equipment, e.g. stationary motors with permanent connections to the permanent installation.
## **Surge category I**
- Equipment that is intended to be connected to the permanent electrical installation of a building. Measures to limit transient surges to the specific level are taken outside the equipment, either in the permanent installation or between the permanent installation and the equipment.
## **Surge category VI**
- Equipment for use at or near the power supplies in the electrical installations of buildings, between the principal distribution and the mains, e.g. electricity meters, circuit-breakers and centralised ripple controllers.
## **Surge category II**
- Equipment to be connected to the permanent electrical installation of a building, e.g. household appliances, portable tools, etc.
## **Pollution severity categories**
## **Pollution severity category 1**
- No pollution, or only dry, nonconductive pollution that has no influence.
## **Pollution severity category 2**
- Non-conductive pollution only; occasional condensation may cause temporary conductivity.
## **Pollution severity category 3**
- Conductive pollution, or dry, nonconductive pollution that is liable to be rendered conductive through condensation.
## **Pollution severity category 4**
- Contamination results in constant conductivity, e.g. caused by conductive dust, rain or snow.
Unless explicitly stated otherwise, the dimensioning of clearance and creepage distances and the resulting rating data for electromechanical products (terminals, terminal strips, PCB connection terminals and plug-in connectors) is based on pollution severity 3 and surge category III, taking account of all network types.
**W.6**
**Electrical data**
## Design of clearances and creepage distances in electrical equipment – influencing factors
## **Rated voltage**
The rated voltage is derived from the nominal voltage of the power supply and the corresponding network type.
|**Single-phase**<br>**2- or 3-wire AC or**|**DC systems**<br>Voltages for table 4<br>For insulation<br>phase-to-phase1)<br>For insulation<br>phase-to-earth1)<br>All systems<br>3-wire systems<br>neutral pt. earthing<br>**V**<br>**V**<br>12.5<br>–<br>25<br>–<br>32<br>–<br>50<br>–<br>63<br>–<br>63<br>32<br>100<br>–<br>125<br>–<br>160<br>–<br>250<br>–<br>250<br>125<br>320<br>–<br>500<br>250<br>630<br>–<br>1000<br>500<br>1000<br>–|**DC systems**<br>Voltages for table 4<br>For insulation<br>phase-to-phase1)<br>For insulation<br>phase-to-earth1)<br>All systems<br>3-wire systems<br>neutral pt. earthing<br>**V**<br>**V**<br>12.5<br>–<br>25<br>–<br>32<br>–<br>50<br>–<br>63<br>–<br>63<br>32<br>100<br>–<br>125<br>–<br>160<br>–<br>250<br>–<br>250<br>125<br>320<br>–<br>500<br>250<br>630<br>–<br>1000<br>500<br>1000<br>–|**3-phase**<br>**3- or 4-wire AC**|**systems**|**systems**|**systems**|
|---|---|---|---|---|---|---|
|Rated voltage<br>of the power sup-<br>ply (mains)*)|Voltages for table 4||Rated voltage<br>of the power<br>supply (mains)*)|Voltages for table 4|||
||For insulation<br>phase-to-phase1)|For insulation<br>phase-to-earth1)||For insulation<br>phase-to-phase|For insulation<br>phase-to-earth||
||All systems|3-wire systems<br>neutral pt. earthing||All systems|3-phase<br>4-wire systems<br>with earthed<br>neutral wire2)|3-phase<br>3-wire systems<br>unearthed1)or<br>phase-earthed|
|**V**|**V**|**V**|**V**|**V**|**V**|**V**|
|12.5|12.5|–|60|63|32|63|
|24 / 25<br>30|25<br>32|–<br>–|110/120/127<br>150**)|125<br>160|80<br>–|125<br>160|
|42 / 48 / 50**)<br>60|50<br>63|–<br>–|208<br>220/230/240|200<br>250|125<br>160|200<br>250|
|30–60|63|32|300**)|320|–|320|
|100**)|100|–|380/400/415|400|250|400|
|110 / 120<br>150**)|125<br>160|–<br>–|440<br>480/500|500<br>500|250<br>320|500<br>500|
|220|250|–|575|630|400|630|
|110–220<br>120–240|250|125|600**)<br>660/690|630<br>630|–<br>400|630<br>630|
|300**)|320|–|720/830|800|500|800|
|220–440|500|250|960|1000|630|1000|
|600**)|630|–|1000**)|1000|–|1000|
|480–960|1000|500|1) Phase-to-earth in<br>systems are equ<br>voltage to earth<br>phase voltage. T<br>mined by the ins<br>phase to earth; t<br>one phase can e<br>voltage to earth.<br>2) For electrical equ<br>3-wire supplies,<br>systems only.<br>*) It is assumed tha<br>lower than the no<br>**) Because of the c<br>not been used in<br>distribution syste<br>while the higher v<br>value is indicated<br>the value phase-<br>The values given<br>and 3b by the **|sulation levels for unearthed or impedance-earthed<br>al to those of phase-to-phase because the operating<br>of any phase can, in practice, reach full phase-to-<br>his is because the actual voltage to earth is deter-<br>ulation resistance and capacitive reactance of each<br>hus, a low (but acceptable) insulation resistance of<br>arth it and raise the other two to full phase-to-phase<br>ipment for use in both 3-phase 4-wire and 3-phase<br>earthed and unearthed, use the values for 3-wire<br>t the rated voltage of the electrical equipment is not<br>minal voltage of the power supply.<br>ommon changes, the meaning of the ** symbol has<br>table 1; i.e. the / symbol indicates a 4-wire 3-phase<br>m. The lower value is the phase-to-neutral voltage,<br>alue is the phase-to-phase voltage. Where only one<br>, it refers to 3-wire 3-phase systems and specifies<br>to-phase.<br>in table 1 are still taken into account in tables 3a<br>symbol.|||
|1000**)|1000|–|||||
||||||||
## **Insulating material group**
The insulating materials are divided into four groups depending on the comparative figures for creepage distance (CTI = comparative tracking index):
## Insulating material group
||I|600|≤|CTI||
|---|---|---|---|---|---|
||II|400|≤|CTI <|600|
||III a<br>III b|175<br>100|≤<br>≤|CTI <<br>CTI <|400<br>175|
The comparative tracking index must be determined using special samples produced for this purpose with test solution A in compliance with IEC 60112 (DIN IEC 60112/DIN VDE 0303-1).
**W**
**W.7**
**General technical information**
## IP class of protection to DIN EN 60529
**W**
## **I P 6 5**
The ingress protection class or IP rating is indicated by a code consisting of the two letters IP and two digits representing the class of protection.
Example: 2nd digit: protection from liquids 1st digit: protection from solid bodies
## **Protection against intrusion of external particle matter**
## **Protection against penetration of liquids**
## **(1st digit)**
## **(2nd digit)**
## **ID number**
## **ID number**
**==> picture [512 x 506] intentionally omitted <==**
**----- Start of picture text -----**<br>
0 No protection 0 No protection<br>Protection against ingress of large solid bodies<br>1 with diameter > 50 mm. (Protection to prevent 1 Protection against drops of condensed water falling<br>dangerous parts being touched with the back of vertically.<br>the hand.)<br>Protection against ingress of large solid bodies with<br>Protection against drops of liquid falling at an angle<br>2 diameter > 12.5 mm. (Protection to prevent danger- 2<br>of 15° with respect to the vertical.<br>ous parts being touched with the fingers.)<br>Protection against ingress of large solid bodies<br>Protection against drops of liquid falling at an angle<br>3 with diameter > 2.5 mm. (Protection to prevent 3<br>of 60° with respect to the vertical.<br>dangerous parts being touched with a tool.)<br>2,5 mm<br>Protection against ingress of large solid bodies with<br>Protection against liquids splashed from any<br>4 diameter > 1 mm. (Protection to prevent dangerous 4 direction.<br>parts being touched with a piece of wire.)<br>1,0 mm<br>Protection against harmful deposits of dust, which<br>Protection against water jets projected by a nozzle<br>5 cannot enter in an amount sufficient to interfere with 5<br>from any direction.<br>satisfactory operation.<br>Protection against water from heavy sea on ships’<br>6 Complete protection against ingress of dust. 6 decks.<br>7 Protection against immersion in water under defined<br>conditions of pressure and time.<br>Protection against indefinite immersion in water<br>8 under defined conditions of pressure (which must be<br>agreed between manufacturer and user and must be<br>more adverse than number 7).<br>1 m<br>**----- End of picture text -----**<br>
**W.8**
**General technical information**
## Conversion table for AWG to mm[2] conductors
## **AWG**
**AWG** is the abbreviation for „ **A** merican **W** ire **G** auge“. This designation bears no resemblance to the actual cross-section of the conductor.
The relationship between AWG and mm[2] is shown in the following table.
## **Plug gauge to IEC 60947-1**
**Insertion of unprepared round conductors with the largest prescribed cross-section**
Test with defined gauge, insertion simply under self-weight
||**AWG**|**mm2**||**Conductor cross-section**|**Conductor cross-section**|**Conductor cross-section**|**Plug gauge**|**Plug gauge**|||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
||28<br>26|0.08<br>0.13|||||**Form A**|||**Form B**|||
||24|0.21|||||||||||
||22|0.22|||||||||||
|20<br>0.52<br>19<br>0.65<br>18<br>0.82<br>17<br>1.04<br>16<br>1.31<br>~~OO~~<br>~~es~~|||||||«|£4|||Bid<br>a||
||15|1.65|||||||||||
||14|2.08|||||||||||
||13|2.63||Flexible||Rigid conductor|Designa-|Diameter|Width|Designa-|Diameter|Permissible|
||12|3.31||conductor||(solid or stranded)|tion|a|b|tion|a|deviation for|
||11|4.17||mm2||mm2||mm|mm||mm|a and b mm|
||10|5.26||1.5||1.5|A 1|2.4|1.5|B 1|1.9||
||9|6.63||2.5||2.5|A 2|2.8|2.0|B 2|2.4|0 – 0.05|
||8|8.37||2.5||4|A 3|2.8|2.4|B 3|2.7||
||7|10.55||4||6|A 4|3.6|3.1|B 4|3.5||
||6|13.30||6||10|A 5|4.3|4.0|B 5|4.4|0 – 0.06|
||5|16.77||10||16|A 6|5.4|5.1|B 6|5.3||
||4|21.15||16||25|A 7|7.1|6.3|B 7|6.9||
||3|26.67||25||35|A 8|8.3|7.8|B 8|8.2|0 – 0.07|
||2|33.63||35||50|A 9|10.2|9.2|B 9|10.0||
||1|42.41||50||70|A 10|12.3|11.0|B 10|12.0||
||0|53.48||70||95|A 11|14.2|13.1|B 11|14.0|0 – 0.08|
|||||95||120|A 12|16.2|15.1|B 12|16.0||
|||||120||150|A 13|18.2|17.0|B 13|18.0||
**W**
**W.9**
**Installation instructions**
## Connecting the terminals
## **Cross-connections systems**
Weidmüller can supply the cross-connections WQV and ZQV – fully insulated against electric shock – with various numbers of poles (2- to 20-pole). Please note that the rated voltage is reduced when using cross-connections.
Protection against electric shock is not provided at the ends of shortened crossconnections.
Such cross-connections must be used with partition plates or end plates in order to maintain the rated voltage.
## **Leaf clamp conductor connection for large cross-sections**
It is no longer the case that conductors with large cross-sections have to be forced into the clamping point. Instead, they can now be easily laid in the modular terminal.
In addition to the individual form, every type of terminal can also be supplied in the form of 3-, 4- and 5-pole blocks. All the blocks are permanently screwed together and therefore guarantee additional rigidity.
Direct mounting is possible thanks to the elongated holes on the underside of the terminals. Terminal blocks can be screwed directly to mounting plates with a 25 mm pitch.
Open cover and remove screw assembly.
The other advantages are:
- Constant force transfer through selfadjusting connection system
- Mounting in any direction
Insert conductor and replace screw assembly.
- Electric shock protection (finger-proof) to German standard VBG 4, also with cross-connections
- Extremely resistant to distortion
Close cover and tighten screw with Allen key.
**W**
**W.10**
**Installation instructions**
## The use of aluminium conductors
Weidmüller modular terminals are suitable for the direct connection of **solid round and sector aluminium conductors** . In contrast to copper, aluminium exhibits certain characteristics that must be taken into account when using this material as a conductor in electrical engineering.
A thin, non-conductive layer of oxide forms immediately on the unprotected surface of the aluminium as soon as it is exposed to the air.
This layer increases the contact resistance between the aluminium conductor and the current bar of the modular terminal. And that, in unfavourable conditions, can lead to poor contact.
And in stranded conductors the contact resistances of the individual strands are added together. Despite these disadvantages, aluminium conductors can be connected to Weidmüller modular terminals, provided the reduced rated currents for aluminium conductors and the following installation conditions are adhered to.
**1.** Scrape the stripped end of the conductor carefully, eg. with a knife, to remove the layer of oxide.
**Caution:** Do not use brushes, files or emery paper because particles of aluminium can be deposited on other conductors.
**2.** After removing the layer of oxide, coat the end of the conductor immediately with a neutral grease, e.g. acid- and alkali-free Vaseline, and connect it to the terminal immediately.
**3.** Repeat the above procedure if at any time the conductor is disconnected and reconnected.
**4.** The above installation instructions are valid for solid round or sector aluminium conductors only.
|~~**Solid round and sector conductors**~~|~~**Solid round and sector conductors**~~||||
|---|---|---|---|---|
|Terminal type|Rated cross-section|Reduced rated|Clamping screw|Tightening torque|
|||current when<br>connecting an|thread size||
|||aluminium conductor|||
|**W-Series**|mm<br>2|„A“||Nm|
|WDU 2.5|2.5|20|M 2.5|0.5-0.8|
|WDU 4|4|27|M 3|0.6-1.0|
|WDU 6<br>WDU 10|6<br>10|35<br>48|M 3.5<br>M 4|1.2-1.6<br>2.0-2.4|
|WDU 16|16|64|M 5|3.0-4.0|
|WDU 35|35|105|M 6|4.0-6.0|
|WDU 70<br>WDU 120|70<br>120|163<br>230|M 8<br>M 10|10.0-12.0<br>15.0-20.0|
|WDU 240|240|–|M 10|12.0-20.0|
|**SAK-Series**<br>SAK 2.5|2.5|20|M 2.5|0.5-0.8|
|SAK 4|4|27|M 3|0.6-1.0|
|SAK 6|6|35|M 3.5|1.2-1.6|
|SAK 10|10|48|M 4|2.0-2.4|
|SAK 16|16|64|M 4|2.0-2.4|
|SAK 35|35|105|M 6|4.0-6.0|
||||||
|~~**Stranded conductors**~~|||||
|**W-Series**|||||
|WFF 35<br>WFF 70|35<br>70|105<br>163|M 6<br>M 8|3.0-6.0<br>6.0-12.0|
|WFF 120|120|230|M 10|10.0-20.0|
|WFF 185<br>WFF 300|185<br>300|300<br>409|M 12<br>M 16|15.5-31.0<br>30.0-60.0|
## **Installation advice when using flat cable lugs**
necessary to fit a copper-plated alu-minium washer between the aluminium cable lug and the copper current bar of the modular terminal. This is the only way of guaranteeing a reliable transition between the copper and the aluminium. Fit the washer in such a way that the copper side is in contact with the current bar, and the aluminium side in contact with the cable lug.
When tightening the terminal it is advisable to hold the conductor to prevent deformation of the terminal rail and to avoid twisting the foot of the terminal. When connecting **stranded aluminium conductors** to modular terminals, it is advisable to use an aluminium cable lug chosen to match the type of conductor and connected according to the instructions of the cable lug manufacturer. It is
**==> picture [309 x 126] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fixing screw<br>4<br>ey eee 2<br>i; | f; | .<br>1 BAA)FFFFAIfeMANA FAIS ASI IFS 3 @<br>1 Al side Current bar<br>5<br>2 Al conductor 4 Al cable lug<br>3 Cu-plated Al washer 5 Cu side<br>**----- End of picture text -----**<br>
**W**
**W.11**
**Connection systems**
## Free choice of connection technology
**==> picture [96 x 79] intentionally omitted <==**
## **Clamping yoke connection technology**
The **Weidmüller clamping yoke system** is an optimum combination of the specific properties of steel and copper. This clamping yoke system has proved its worth in billions of Weidmüller products over many decades. Both the clamping yoke and the clamping screw are made from hardened steel. This clamping yoke arrangement generates the necessary contact force. The clamping yoke presses the incoming conductor against a current bar made of copper or high-quality brass. The hardened Weidmüller clamping yoke ensures a gastight, vibration-resistant connection between conductor and current bar.
**==> picture [48 x 90] intentionally omitted <==**
## **TOP connection technology**
The Weidmüller **TOP connection system** ensures that the conductor can be inserted and the clamping screw tightened from the same direction. Such an arrangement eases the wiring work in certain installations, e.g. when there is little space at the sides in terminal boxes. The TOP connection system combines the specific properties of steel and copper. The hardened steel lever presses the conductor directly against **W** a current bar made of copper or highquality brass. The high contact force guarantees a gas-tight connection between conductor and current bar.
**==> picture [80 x 81] intentionally omitted <==**
**Leaf spring connection technology**
Weidmüller’s patented **leaf clamp connection system** is a screw connection system for large conductor cross-sections. The insertion of large conductors into the clamping point is made easier here by the fact that the clamping unit can be removed first. The conductor can then be placed directly on the current bar before re-inserting the clamping unit and tightening the screw to grip the conductor.
**==> picture [67 x 104] intentionally omitted <==**
**Tension clamp connection technology**
The **Weidmüller tension clamp system** functions similarly to the tried-and-tested clamping yoke. Here again, the mechanical and electrical functions are kept separate. The spring made from high-quality rustproof and acid-proof steel pulls the conductor against the tin-plated copper current bar. Treating the copper in this way ensures low contact resistance and high corrosion resistance. The compensating effect of the spring ensures a secure contact for the lifetime of the terminal.
**==> picture [48 x 81] intentionally omitted <==**
## **IDC connection technology**
The **IDC connection technology** (Insulation Displacement Connection) is a type of connection for copper conductors that does not require the conductor to be prepared in any way – so no stripping and no crimping.
When connecting the conductor, the insulation of the conductor is penetrated and an electrically conductive contact between conductor and current bar produced at the same time.
The Weidmüller IDC principle, like Weidmüller’s other types of connection, again keeps mechanical and electrical functions separate.
A spring made from rustproof stainless steel presses the current bar onto the conductor and therefore guarantees a low contact resistance and a gas-tight, vibration-resistant connection.
**W.12**
**Connection systems**
**==> picture [110 x 104] intentionally omitted <==**
## **Push In-Connection technology**
In the **Push In connection technology** the stripped solid conductor is simply inserted into the clamping point as far as it will go. And that completes the connection! No tools are required and the result is a reliable, vibration-resistant and gas-tight connection. Even flexible conductors with crimped wire end ferrules or ultrasonic-welded conductors can be connected without any problems. A stainless steel spring, which is fitted in a separate housing, guarantees a high contact force between the conductor and the current bar (tin-plated copper). The conductor pull-out force for this system is even higher than that for the tension clamp system. Spring stop plus conductor stop in a steel housing ensure optimum connection conditions and a guide for the screwdriver needed to detach the conductor.
## **The principle of vibration resistance**
## **Clamping yoke**
As the clamping screw is tightened, the ensuing force causes the upper threaded part to spring back and exert a locknut effect on the screw. The Weidmüller clamping yoke system is vibration-resistant. The relaxation of the conductor is compensated for by the elastic behaviour of the Weidmüller clamping yoke. It is therefore not necessary to retighten the clamping screw.
## **Leaf clamp**
The distance “d” between the shaft of the clamping screw and the leaf clamp causes elastic deformation of the spring as the screw is tightened. The vibration resistance depends on the magnitude of the spring force of the leaf clamp, and this force also compensates for relaxation phenomena in the conductor. It is therefore not necessary to retighten the clamping screw.
## **TOP**
Like with the clamping yoke, the force exerted by the steel lever as the screw is tightened forces apart the two threaded parts of the TOP connection. This exerts a locking effect on the screw and guarantees excellent vibration resistance.
**==> picture [52 x 116] intentionally omitted <==**
**==> picture [53 x 116] intentionally omitted <==**
**==> picture [129 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
d<br>**----- End of picture text -----**<br>
**==> picture [43 x 111] intentionally omitted <==**
**W**
**W.13**
**Terminals**
## Regulations / definitions
## **Terminals acc. to VDE 0611-1**
This standard was published in Germany in August 1992:
VDE 0611-1 Low-voltage switchgear part 7: Ancillary equipment section 1 – Terminal blocks for copper conductors.
The contents of this standard correspond to the international standard: IEC 60947-7-1:
1989 Low voltage switchgear and control gear part 7: Ancillary equipment section 1 – Terminal blocks for copper conductors
At the European level this standard has been ratified by CENELEC, making it valid in the following countries:
Austria, Belgium, Denmark, Finland, France, Germany, Greece, Holland, Iceland, Ireland, Italy, Luxembourg, Norway, Portugal, Spain, Sweden, Switzerland, United Kingdom
Combined application in order of priority: IEC 60947-1
Low-voltage switchgear and control gear part 1: General Rules EN 60947-1 VDE 0660 part 100 Low-voltage switchgear part 1: General Rule
## **Scope VDE 0611-1**
(EN 60947-7-1)
(IEC 60947-7-1)
This standard stipulates the requirements for terminals with screwed or screwless terminal strips intended primarily for industrial or similar use, with the terminals fastened to a carrier to produce both electrical and mechanical connections between copper conductors. It applies to terminals used for connecting round copper conduc- **W** tors with a cross-section between 0.2 mm[2 ] and 300 mm[2] (AWG 24/600 kcmil), and for electronic circuits up to 1000 V AC 1000 Hz or up to 1500 V DC.
## **Remarks:**
This standard is also used as guide for special kinds of terminals (e.g. isolating terminals) for which no special standards are available.
## **Terminals/**
## **feed-through terminals**
An insulating part which carries one or several mutually insulated terminal arrays intended for fastening to a carrier.
## **Rated cross-section**
The rated cross-section of a terminal is the cross-section of the conductor to be connected by the terminal as stated by the manufacturer. It is determined by certain thermal, mechanical and electrical requirements, and is one of the specifications marked on the terminal.
The rated cross-section is selected from the following standard cross-sections: 0.2 - 0.5 - 0.75 - 1.0 - 1.5 - 2.5 - 4.0 - 6.0 - 10 - 16 - 25 - 35 - 50 - 70 - 95 - 120 - 150 - 240 - 300 mm[2] .
The terminals have a rated connection capability, which is at least two stages smaller than the rated cross-section. The conductors may be solid, stranded or flexible and, if necessary, may have their ends pre-treated. The rated cross-section is verified using the gauges stipulated by VDE 0660 part 100 table 7 (see page W.14).
## **Rated current**
Each rated cross-section is assigned a particular test current stipulated by VDE 0611-1. At these rated currents, terminals are not subject to nonpermis sible increases in temperature:
**==> picture [163 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
mm [2] 1.5 2.5 4.0 6.0<br>A 17.5 24 32 41<br>mm [2] 10 16 25 35<br>A 57 76 101 125<br>mm [2] 50 70 95 120<br>A 150 192 232 269<br>mm [2] 150 185 240 300<br>A 309 353 415 520<br>**----- End of picture text -----**<br>
## **Rated voltage VDE 0611-1 / VDE 0660 part 100**
The rated voltage of a terminal is the rated insulation voltage to which the insulation tests and creepage distances refer. It is defined analogously to DIN VDE 0110-1, and is one of the specifications marked on the terminal.
## **Rated surge voltage DIN VDE 0110-1 / VDE 0660 part 100**
Peak values of a surge voltage which can be applied to the terminals and to which the clearance distances acc. to VDE 0660 part 100 or DIN VDE 0110-1 refer.
## **Degree of soilin DIN VDE 0110-1 / VDE 0660 part 100**
The degree of soiling stipulates the influence of solid, liquid or gaseous foreign particles, which may reduce the dielectric strength or specific surface resistance (see also page W.5).
Terminals for use in the industrial field of application are assigned degree of soiling 3: either conductive contamination may occur or, alternatively, dry, non-conductive contamination which becomes conductive in the likely event of condensation. The minimum clearance distance is stipulated in combination with the rated surge voltage in VDE 0660 part 100 or DIN VDE 0110-1.
**W.14**
**Terminals**
## The assembly of terminal rails
## **Operating conditions**
Terminals can be operated under the following normal conditions:
- Ambient temperature –5 °C … +40 °C, mean temperature 24 h + 35 °C
- Altitude up to 2000 m a.s.l.
- Relative humidity 50 % at + 40 °C, 90 % at 20 °C.
## **CE mark**
A EU directive stipulates that labelling with the CE mark is carried out by the manufacturer. The mark indicates to the state authorities that the item complies with the relevant directives. It thus guarantees free trade within Europe. Conductor connectors from ≥ 50 V ~ / 75 V- comply with the basic safety requirements stated in the low-voltage directive 73/23/EEC (amended by 93/68/EEC). CE marking acc. to the marking directive 93/68/EEC has been mandatory since 1 January 1997. It is affixed to the packaging. Declarations of conformity are kept available for inspection by the relevant national supervisory agencies as part of the technical documentation.
## **Combinations of different terminals**
- End plates or partition plates (WAP/TW, ZAP/TW and IAP) must be used when the contour changes.
- For adjacent terminals with differing rated voltages, end plates or partition plates (WAP/TW, ZAP/TW and IAP) must be used in order that the respective rated voltages are adhered to.
- When the PE terminal is positioned next to or between corresponding feedthrough terminals of the same series and size, this does not influence the rated voltage or rated surge voltage of the feed-through terminals.
## **Dimensions**
The overall dimensions of the terminals with fastening parts are stipulated, but without tolerances. A mounting tolerance of 0.2 mm must be added to the terminal width when planning projects.
## **Partition plate**
The partition plate is necessary for visual separation of circuits or for electrical separation of neighbouring crossconnections.
## **Working on electrical connection elements with non-insulated screwdrivers**
Work using non-insulated screwdrivers may only be carried out in disconnected systems.
The following five safety rules must be observed when disconnecting a system before beginning work and in order to ensure the system remains disconnected at the working site for the duration of this work:
- **Disconnect**
- **Secure to prevent the system from being switched on again**
- **Ascertain that the system is not live**
- **Earth and short circuit the system**
- **Cover or cordon off any neighbouring live parts**
These five rules constitute the safety precautions for working with electrical systems and equipment. The measures to be taken in accordance with operating and local conditions, e.g. for high- and low-voltage overhead lines, cables or switchgear, are stipulated in detail in VDE 0105 part 100.
## **Live terminals which are not in use**
## **Mounting and end brackets**
- Terminal strips mounted from left to right
- Closed side on the left, open side on the right
- Open side of the terminal always closed using end plates or partition plates (WAP/TW; ZAP/TW and IAP)
- End brackets placed at the beginning and end of the terminal strip
- End bracket not required next to PE terminals. Exceptions: WDK/PE and ZPE
## **Partition disc**
Any terminals which are not in use and which could carry live voltage are to be fitted with suitable covers (e.g. ADP 1...4) to prevent them from being inadvertently touched. The clamping screws of terminals, which are not in use, even those that are not live, are to be screwed tight.
Partition discs can be retrofitted between cross connectors or sockets in terminals up to a max. terminal width of 12 mm.
## **Compliance with the rated insulation voltage**
The required stripping length for every Weidmüller product is stated in mm. **VDE 0105 part 100** These lengths, such as < 6 mm ± 0.5 mm, **Operation of electrical installations:** > 10 mm ± 1 mm, must be adhered to. **Work** This also applies when using ferrules. The external dimensions of crimped Troubleshooting with two-pole voltage ferrules must comply with IE 60947-1 detectors including voltage tester acc. (1999 version). to IEC 61243-3.
**W**
**W.15**
**Definitions of the various terminal types**
## Definitions of the various terminal types
## **PE terminals**
## **Fuse terminals**
## **Multi-level distribution terminals**
**==> picture [8 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
PE<br>**----- End of picture text -----**<br>
A PE terminal is a component with one or several clamping points for connecting and/ or branching PE conductors (PE and PEN conductors) with a conductive connection to their mountings. Partly insulated PE terminals are insulated from adjacent live parts of terminals; the partial insulation is coloured green/yellow.
## **Applications** (IEC 60947-7-2)
This standard applies to PE terminals with PE function up to 120 mm[2] and to PE terminals with PEN function for sizes upwards of 10 mm[2] with clamping points with or without screws for connecting round copper conductors with a crosssection between 0.2 and 120 mm[2] (AWG 24/250 kcmil) for circuits up to 1000 Vac 1000 Hz or up to 1500 Vdc. PE terminals are used to produce the electrical and mechanical connections between copper conductors and the mounting.
Fuse terminals consist of a terminal base and a cartridge fuse holder. In the case of fuse terminals for low-voltage cartridge fuses (D-system), the technical data are defined by IEC 60947-7-3 in conjunction with VDE 0636 part 301.
In the case of fuse terminals for device protection cartridge fuses, the technical data are defined by IEC 60947-7-3, which covers the range of applications of such products.
Fuse terminals for protecting devices are rated for a certain maximum power loss on the basis of IEC 60127-2, which covers G-type cartridge fuses.
The product pages contain details of the maximum power loss for individual or group arrangements for short-circuit and/ or overload protection.
A multi-level distribution terminal is a unit with clamping points for connecting and/ or linking phase, neutral and PE conductors to their mountings with a conductive PE connection. They have several connection levels, all isolated from each other.
## **Applications IEC 60947-7-1 / IEC 60947-7-2 DIN VDE 0611-4 (partly)**
These standards apply to multi-level distribution terminals with clamping points with/without screws for connecting or linking solid, stranded or flexible copper conductors. In distribution terminals, phase conductor and/or N and PE conductor connections are all realised in a compact space.
The N-conductor can be disconnected for insulation measurements; it is not used for disconnecting or switching.
## **PEN function**
According to IEC 60947-7-2, only copper terminal rails may be used for the PEN function. Steel terminal rails may not be used.
## **Use of TS 35 x 15**
**W**
In order to comply with the current-carrying ability required by IEC 60947-7-2, the TS 35 x 15 terminal rail must be used for PE terminals with a rated cross-section of 16 mm[2] and upwards.
**W.16**
**Definitions of the various terminal types**
## **N-conductor disconnect terminals**
## **Test-disconnect terminals**
NT
A neutral-conductor disconnect terminal is a special type of test-disconnect terminal with lateral disconnection. It is connected to a neutral-conductor busbar. It will be covered in the scope of the IEC 60947-7-1 (2008 edition – Appendix D). The terminals are used for measuring the insulation resistance relative to the earth. They enable simple testing without the need to disconnect the neutral conductor.
## **Dimensioning of clearance and creepage distances:**
Test-disconnect terminals are used for the short-term separation of circuits in order to perform test and measurements in a no-voltage state. They will be covered in the scope of the IEC 60947-7-1 (2008 edition – Appendix D). The dimensions for the clearance and creepage distances of the opened disconnect points are not evaluated. However the rated surge voltage resistance (supplied by the manufacturer) must be verified at the opened disconnect point.
400 V applies to phase conductor–phase conductor 250 V applies to phase conductor–N-conductor phase conductor–PE conductor N-conductor–PE conductor
**W** a
**W.17**
**ATEX**
## ATEX terminals
## **Confirmed according to the new European Ex-Directive 94/9/EC – ATEX –**
## **Basic specifications**
IEC 60947-7-1 (EN 60 947-7-1/ VDE 0611P.1) and IEC 60 947-7-2 (EN 60 947-7-2/ VDE 0611P.3) are the basic specifications for terminals, and also protective conductor terminals. For use in potentially explosive atmospheres the following standards also apply: EN 50 014 (IEC 60 079-0/VDE 0170/0171 P.1) and for increased safety “e” EN 50 019 (IEC 60 079-7/ VDE 0170/0171 P. 6). Ex terminals are so-called Ex-components according to EN 50014.
Components means any item essential to the safe functioning of equipment and protective systems, but with no autonomous function.
Components according to the ATEX-directive 94/9/EC are not marked with CE.
Ex terminals are certified for the type of protection increased safety “e”.
According to the directive 94/9/EC, the European notified bodies have been issuing Ex-type examination certificates of the so-called ATEX-Generation in accordance with EN 50014 / 50019 and the Ex directive 94/9/EC.
KEMA, the authorized notified body and publisher of the Production Quality Assurance Notification, has confirmed with this publication that the manufacturer meets the requirements of the ATEX Directive according to the appendices IV and VII. Copies of the EC-type examination certificates, the notification documents and the declaration of conformity are available on the Internet. The clamping yoke, tension clamp, IDC, and Push-In terminal connection systems offer increased protection against accidental loosening. They are designed and shaped so that the end strands from flexible wires do not require any preparation.
## Marking
> **RL94/9EG:** T II 2 G-D
T Ex electrical equipment
II 2-G Equipment group II category 2 (zone 1 electrical equipment) II 2-D Equipment group II category 2 (zone 21 electrical equipment) **EN 60079-7:** Ex e II Ex Explosion protection e Increased safety II Equipment group **KEMA 97ATEX4677U** (Example)
**W**
KEMA Notified body ATEX Conformity with 94/9/EG U Component
**W.18**
**ATEX**
## **Confirmed according to the new European Ex-Directive 94/9/EC – ATEX –**
If the real ambient temperature is higher, the permitted operating current must be reduced accordingly. As defined in EN 50 014, the continuous operating temperature for Wemid and KrG is 100 °C, for PA material 80 ºC.
## **Electrical data**
The specified values of the current carrying capacity are related to an ambient temperature of 40 °C. At rated current load (+ 10%), the temperature of the currentbar of the terminal increases by a maximum of 40 K. Recognizing an additional factor of safety according to EN 50 014, gives the following results:
## **Accessories**
The accessories listed in the tables can be used, and are listed in the Ex certifications. To maintain the creepage and clearance distances for “e”, end plates or partitions should be used, as specified in the table.
|~~**Temperature class**~~|~~**Ambient temperature**~~|
|---|---|
|T6|-50 °C to +40 °C|
|T5 to T1|-50 °C to +55 °C|
## **Current carrying capacity of cables and conductors**
|||||
|---|---|---|---|
|1.5<br>2.5<br>4<br>6<br>10<br>16<br>25<br>35<br>50<br>70<br>90<br>120<br>150<br>185<br>240<br>300<br>Cross-section|VDE 0298 Part 4 (IEC364-5-523)<br>Current carrying capacity of conductors|||
||||EN 50019 2nd. edtition<br>Increased-safety type of pro-<br>tection connection terminals<br>Ambient temperature 40 °C<br>40 K rise<br>Current equivalent to<br>connect conductor<br>A|
|||||
||Ambient temperature 30 °C<br>Routing type C + 3<br>for PVC 70 °C conductors<br>A|Ambient temperature 40 °C<br>Factor 0.87<br>Routing type C + 3<br>for PVC 70 °C conduct<br>A||
||17.5<br>24<br>32<br>41<br>57<br>76<br>101<br>125<br>150<br>192<br>232<br>269<br>309<br>353<br>415<br>520|15.225<br>20.88<br>27.84<br>35.67<br>49.59<br>66.12<br>87.87<br>108.75<br>130.5<br>167.04<br>201.84<br>234.03<br>268.83<br>307.11<br>361.05<br>452.4|15<br>21<br>28<br>36<br>50<br>66<br>88<br>109<br>131<br>167<br>202<br>234<br>267<br>307<br>361<br>452|
The current carrying capacity of cables and conductors in the installation is normally specified at 30 °C ambient temperature according to VDE 0298 Part 4. At 40 °C, the operating current shall be reduced by a factor of 0.87.
## **Design for Ex i**
Terminals for “i” intrinsically-safe circuits are passive components. Therefore, there is no requirement for certification when being used in intrinsicallysafe circuits. The terminals are light blue to ensure clear identification and easy recognition. The construction type of these terminals must comply with EN 60079-11.
You may request additional information from Weidmüller concerning the use of our terminals in intrinsically-safe circuits.
## **Accessories**
The listed accessory can be used. It must comply with EN 60079-11.
## **Mounting**
The general statements also apply here for Ex i applications. Additionally, the Ex i requirements always apply to the complete circuit, therefore also for parts in nonpotentially explosive atmospheres.
## **Clampability of 2 conductors in Ex e**
With our W series of terminals, it is normally permitted to connect two wires per terminal point. It is, however, necessary to use the next size down from the rated wire cross-section.
**W**
**W.19**
**ATEX**
## ATEX directives
## **Class of protection**
Since July 1, 2003, all new facilities in explosion risk zones must be certified according to ATEX Directive 94/9/EG or ATEX 95 (ATEX: ATmosphère EXplosive = explosive atmosphere). This directive is one of the „New Approach“ directives. It is valid in all European Union countries, as well as Iceland, Lichtenstein and Norway. In these countries, the directive refers to the sale and commissioning of products which have been designed particularly for high explosion risk environments (where explosive atmospheres exist due to gases, vapours, mists, or dusts). It now also covers the mining sector and purely mechanical devices.
|||~~**Type of protection**~~|~~**Code**~~|~~**CENELEC EN**~~|~~**IEC**~~|~~**Product category**~~||
|---|---|---|---|---|---|---|---|
|||||||~~**explosion protect.**~~||
|||General requirements|–|60079-0|60079-0|–||
||<br> <br>|Oil immersion<br>Pressurised apparatus<br>Powder filling|o<br>p<br>q|60079-6<br>60079-2<br>60079-5|60079-6<br>60079-2<br>60079-5|2<br>2<br>2||
|||Flameproof enclosure|d|60079-1|60079-1|2||
|||Increased safety|e|60079-7|60079-7|2||
|||Intrinsic safety|ia|60079-11|60079-11|1||
|||Intrinsic safety|ib|60079-11|60079-11|2||
||<br>|Intrinsic safety<br>Type n(Ex n)|ic<br>n|60079-11<br>60079-15|60079-11<br>60079-15|3<br>3||
|||Encapsulation|m|60079-18|60079-18|2||
## **Classification for potentially explosive areas**
|**Classification for potentially explosive**|**areas**|
|---|---|
|<br>|~~**Product**~~<br>~~**US classifi-**~~<br>~~**Combustible**~~<br>~~**category**~~<br>~~**cation NEC 500 media**~~<br>1G<br>Class I, Div 1<br>gases, vapours<br>1D<br>Class II, Div 1<br>dust<br>2G<br>Class I, Div 1<br>gases, vapours<br>2D<br>Class II, Div 1<br>dust<br>3G<br>Class I, Div 2<br>gases, vapours<br>3D<br>Class II, Div 2<br>dust|
|~~**CENELEC**~~<br>~~**Presence of potentially**~~<br> <br>||
|~~**classification**~~<br>~~**explosive atmosphere**~~<br>||
|~~**IEC60079-10**~~<br>Zone 0<br>permanent, long-term<br>Zone 20<br>or frequently||
|Zone 1<br>occasionally<br>Zone 20||
|Zone 2<br>rarely and<br>Zone 22<br>briefly||
## **Explosion groups**
|~~**Gas (e.g.)**~~|~~**CENELEC**~~|~~**NEC 500**~~|
|---|---|---|
||||
|Propane|IIA|D|
|Ethylene|IIB|C|
|Hydrogen|IIC|B|
|Acetylene|IIC|A|
|Methane (mining)|I|mining (MSHA)|
## **Temperature classes**
**W**
||~~**Max. surface**~~|~~**Temperature class**~~|~~**Temperature class**~~||
|---|---|---|---|---|
||~~**temperature (°C)**~~|~~**CENELEC**~~|~~**NEC 500-3**~~||
||450|T1|T1||
||300|T2|T2||
||280|–|T2A||
||260|–|T2B||
||230|–|T2C||
||215|–|T2D||
||200|T3|T3||
||180|–|T3A||
||165|–|T3B||
||160|–|T3C||
||135|T4|T4||
||120|–|T4A||
||100|T5|T5||
||85|T6|T6||
**W.20**
**ATEX**
## ATEX codes
## **Example of marking – modular terminal WDK 4 N V**
- @ **1** • Rated voltage
- @ **2** • European symbol for explosion protection
- **3** • Certificate number
- @
- **4** • Rated conductor cross-section
- @
- **5** • CENELEC protection type “e”
- @ group II (gases, vapours, mists)
- Product category 2 – for use in zone 1 or 2
- Approved for use in gases “G” and dusts “D”
**Example of marking – enclosure fitted with components for enhanced safely**
- Type designation
- Serial number
- Approved for use in gases “G”
- e **4** • Product category 2 – for use in zone 1 or 2
- **5**
- e@
- **5** • Approved for use in dusts “D”
- CENELEC protection type “e” – increased safety
**13**
- Ambient temperature range deviating from the standard
- CENELEC protection type tD
- @ **9** • Temperature class, e.g. T6 (gas), and max. surface temperature (dust) (for example T6 T85 °C)
- **10** • Certificate number @
- ° **11** • Rated voltage
**==> picture [12 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
W<br>**----- End of picture text -----**<br>
**12** • Rated current @ **13** • Power loss @
**W.21**
**ATEX**
## ATEX cross-connection instructions
## **Arrangements of terminals and cross-connections**
**The maximum voltages for Ex e applications given below are determined on the basis of the terminals used, their cross-connections and which of the arrangements (A to J) is used.**
**W**
## **A Continuous**
## **C Adjacent (used with QV)**
## **D Bypassing**
**E Adjacent to a PE terminal** bridging one or several unconnected **(earth)** terminals (e.g. every third) **Without** partition
**separated** with a partition
**==> picture [92 x 53] intentionally omitted <==**
**==> picture [92 x 53] intentionally omitted <==**
**==> picture [92 x 53] intentionally omitted <==**
**==> picture [94 x 52] intentionally omitted <==**
**F Adjacent to a PE terminal G Bypassing a PE terminal (earth) (earth) with** partition
**H 2 parallel cross-connections**
**I 3 parallel cross-connections**
**==> picture [92 x 52] intentionally omitted <==**
**==> picture [92 x 52] intentionally omitted <==**
**==> picture [92 x 52] intentionally omitted <==**
**==> picture [94 x 52] intentionally omitted <==**
## **Maximum voltage**
**==> picture [513 x 300] intentionally omitted <==**
**----- Start of picture text -----**<br>
Range [1)] Certificate No. Rated Rated Rated current Nominal Maximum voltage (V)<br>voltage current with QV cross-section (letters refer to the above diagrams)<br>AKZ… / V / A / A / mm² A C D E F G H I<br>AKZ 1.5 SIRA 02ATEX3001 U 176 15 15 1.5 176 176 -- 176 176 -- -- --<br>AKZ 2.5 SIRA 02ATEX3001 U 176 21 21 2.5 176 176 -- 176 176 -- -- --<br>AKZ 4 SIRA 02ATEX3001 U 275 28 28 4 275 275 -- 275 275 -- -- --<br>BK…<br>BK 2/E ... BK 12/E SIRA 01ATEX3247 U 275 28 25 4 176 -- -- -- -- -- -- --<br>DK 4 …<br>DK 4 SIRA 02ATEX3316 U 275 28 21 4 275 275 -- 275 275 -- -- --<br>DK 4Q SIRA 02ATEX3316 U 275 28 21 4 275 275 -- 275 275 -- -- --<br>DK 4QV SIRA 02ATEX3316 U 275 28 21 4 275 275 -- 275 275 -- -- --<br>I ... Series<br>IDK 1.5N KEMA 02ATEX2241 U 275 15 15 1.5 275 275 275 -- -- -- -- --<br>IDK 1.5N/V KEMA 02ATEX2241 U 275 15 15 1.5 275 275 275 -- -- -- -- --<br>IDU 1.5N KEMA 02ATEX2241 U 275 15 15 1.5 275 275 275 275 275 275 275 --<br>IDU 1.5N/2X2AN KEMA 02ATEX2241 U 275 15 15 1.5 275 275 275 275 275 275 275<br>IDU 1.5N/ZF KEMA 02ATEX2241 U 275 15 15 1.5 275 275 275 275 275 275 275 --<br>IDU 1.5N/3AN/ZF KEMA 02ATEX2241 U 275 15 15 1.5 275 275 275 275 275 275 275<br>IDU 1.5N/ZB KEMA 02ATEX2241 U 275 15 15 1.5 275 275 275 275 275 275 275 --<br>IDU 1.5N/3AN/ZB KEMA 02ATEX2241 U 275 15 15 1.5 275 275 275 275 275 275 275<br>IDU 2.5N DEMKO 03ATEX134054 U 550 21 21 2.5 550 550 550 550 550 550 -- --<br>IDU 2.5N/3AN DEMKO 03ATEX134054 U 550 21 21 2.5 550 550 550 550 550 550 -- --<br>IDU 2.5N/4AN DEMKO 03ATEX134054 U 550 21 21 2.5 550 550 550 550 550 550 -- --<br>IDU 2.5N/2x2AN DEMKO 03ATEX134054 U 550 21 21 2.5 550 550 550 550 550 550 -- --<br>IDU 2.5N/ZF DEMKO 03ATEX134054 U 550 21 21 2.5 550 550 275 550 550 275 -- --<br>IDU 2.5N/ZB DEMKO 03ATEX134054 U 550 21 21 2.5 550 550 275 550 550 275 -- --<br>MK …<br>MK 3/…/E SIRA 01ATEX3248U 275 21 21 2.5 176 -- -- -- -- -- -- --<br>MK 6/…/E SIRA 01ATEX3249U 440 36 36 6 275 -- -- -- -- -- -- --<br>1) Please refer to the catalogue and the certificate for details of precisely which article is approved.<br>**----- End of picture text -----**<br>
**W.22**
**ATEX**
## **Maximum voltage**
**==> picture [513 x 588] intentionally omitted <==**
**----- Start of picture text -----**<br>
Range [1)] Certificate No. Rated Rated Rated current Nominal Maximum voltage (V)<br>voltage current with QV cross-section (letters refer to the above diagrams)<br>P … / V / A / A / mm² A C D E F G H I<br>PDU 2.5/4 KEMA 06ATEX0177U 550 29 25.5 4 275 550 176 275 275 176 176<br>PDU 2.5/4/3AN KEMA 06ATEX0177U 550 29 25.5 4 275 550 176 275 275 176 176<br>PDU 2.5/4/4AN KEMA 06ATEX0177U 550 29 26.5 4 275 550 176 275 275 176 176<br>PDU 6/10 KEMA 06ATEX0177U 550 37 26.5 6 550 550 275 550 550 -- 220<br>PDU 6/10/3AN KEMA 06ATEX0177U 550 36.5 29.5 6 550 550 275 550 550 -- 220<br>PDU 16 KEMA 06ATEX0177U 550 59 57.5 16 275 550 -- 275 275 -- 110<br>PEI 16 KEMA 06ATEX0177U 550 66.5 25 (37) [4)] 16 275 -- -- -- -- -- --<br>SAK …TS 32/TS 35<br>SAK 2.5 KEMA 97ATEX1798 U 550 21 21 2,5 550 550 176 550 550 -- -- --<br>SAK 4 KEMA 97ATEX1798 U 550 28 28 4 550 550 176 550 550 -- -- --<br>SAK 6N KEMA 97ATEX1798 U 550 36 36 6 550 550 176 550 550 -- -- --<br>SAK 10 KEMA 97ATEX1798 U 550 50 50 10 550 550 176 550 550 -- -- --<br>SAK 16 KEMA 97ATEX1798 U 690 66 66 16 550 550 176 690 690 -- -- --<br>SAK 35 KEMA 97ATEX1798 U 550 109 99 35 550 550 176 550 550 -- -- --<br>SAK … EN on TS32<br>SAK 2.5 EN KEMA 97ATEX1798 U 440 21 21 2.5 440 440 440 440 440 -- -- --<br>SAK 4 EN KEMA 97ATEX1798 U 440 28 28 4 440 440 440 440 440 -- -- --<br>SAK 6N EN KEMA 97ATEX1798 U 440 36 36 6 440 440 440 440 440 -- -- --<br>SAK 10 EN KEMA 97ATEX1798 U 440 50 50 10 440 440 440 440 440 -- -- --<br>SAK 16 EN KEMA 97ATEX1798 U 440 66 66 16 440 440 440 440 440 -- -- --<br>SAK 35 EN KEMA 97ATEX1798 U 440 109 109 35 440 440 440 440 440 -- -- --<br>SAK … EN on TS35<br>SAK 2.5 EN KEMA 97ATEX1798 U 690 21 21 2.5 690 690 440 690 690 -- -- --<br>SAK 4 EN KEMA 97ATEX1798 U 690 28 28 4 690 690 690 690 690 -- -- --<br>SAK 6N EN KEMA 97ATEX1798 U 690 36 36 6 690 690 690 690 690 -- -- --<br>SAK 10 EN KEMA 97ATEX1798 U 690 50 50 10 690 690 690 690 690 -- -- --<br>SAK 16 EN KEMA 97ATEX1798 U 690 66 66 16 690 690 690 690 690 -- -- --<br>SAK 35 EN KEMA 97ATEX1798 U 690 109 109 35 690 690 690 690 690 -- -- --<br>SAK 4 EP/SAKH 6-35 EP<br>SAK 4 EP/SW KEMA05ATEX2061U 550 32 32 4 550 550 176 550 550 --<br>SAKH 6 EP/SW KEMA05ATEX2061U 1100 57 57 10 1100 1100 176 1100 1100 --<br>SAKH 10 EP/SW KEMA05ATEX2061U 1100 57 57 10 1100 1100 176 1100 1100 --<br>SAKH 35 EP/SW KEMA05ATEX2061U 1100 125 125 35 1100 1100 440 1100 1100 --<br>SAKK …<br>SAKK 4 SIRA 03 ATEX3425 U 275 28 28 4 275 275 -- 275 275 --<br>SAKK 10 SIRA 03 ATEX3425 U 275 50 50 10 275 275 -- 275 275 --<br>W …<br>WDK 1.5/R3.5 KEMA 99ATEX6545 U 275 14 11 1.5 176 275 -- -- -- -- -- --<br>WDK 2.5 KEMA 98ATEX1687 U 275 21 21 2.5 275 275 60 275 275 60 -- --<br>WDK 2.5V KEMA 98ATEX1687 U 275 21 21 2.5 275 275 60 275 275 60 -- --<br>WDK 2.5DU-PE KEMA 98ATEX1687 U 275 21 21 2.5 275 275 60 275 275 60 -- --<br>WDK 2.5/EX KEMA 98ATEX1687 U 440 24 22 2.5 440 440 176 440 440 176 -- --<br>WDK 2.5N KEMA 00ATEX2061 U 550 21 21 2.5 550 550 275 550 550 275 -- --<br>WDK 2.5N V KEMA 00ATEX2061 U 550 21 21 2.5 550 550 275 550 550 275 -- --<br>WDK 4N KEMA 00ATEX2061 U 550 28 28 4 550 550 275 550 550 275 -- --<br>WDK 4N V KEMA 00ATEX2061 U 550 28 28 4 550 550 275 550 550 275 -- --<br>WDU 1.5/ZZ KEMA 98ATEX1685 U 550 15 15 1.5 550 550 110 550 550 110 110 --<br>WDU 2.5/1.5/ZR KEMA 98ATEX1685 U 550 15 15 1.5 550 550 110 550 550 110 110 --<br>WDU 1.5/R3.5 KEMA 99ATEX6545 U 275 15 11 1.5 176 275 -- -- -- -- -- --<br>WDU 2.5N KEMA 98ATEX1683 U 440 21 21 2.5 440 440 110 440 440 110 -- --<br>WDU 2.5 KEMA 98ATEX1683 U 550 21 21 2.5 550 550 110 440 550 110 110 [2)] 60 [3)]<br>WDU 4 KEMA 98ATEX1683 U 690 28 28 4 690 690 110 440 690 110 -- --<br>WDU 4N TÜV 04ATEX2630 U 440 27 27 4 440 275 69 440 440 69 69 --<br>WDU 6 KEMA 98ATEX1683 U 550 36 36 6 550 550 110 440 550 110 -- --<br>WDU 10 KEMA 98ATEX1683 U 550 50 50 10 550 550 110 440 550 110 -- --<br>WDU 16 KEMA 98ATEX1683 U 690 66 66 16 690 690 110 690 690 110 -- --<br>WDU 35 KEMA 98ATEX1683 U 690 109 109 35 690 690 110 690 690 110 -- --<br>WDU 50N KEMA 98ATEX1683 U 690 126 126 50 550 -- -- 550 550 -- -- --<br>WDU 70N KEMA 98ATEX1683 U 690 167 167 70 550 -- -- 550 550 -- -- --<br>WDU 70/95 KEMA 98ATEX1686 U 690 202 202 95 690 -- -- 690 690 -- -- --<br>1) Please refer to the catalogue and the certificate for details of precisely which article is approved. 2) The outer cross-connection openings must be used for type ZQV.<br>4) For PDU2.5/4 and ZQV 2.5 cross-connection: 25 A; For PDU 6/10 and ZQV 6N cross-connection: 37 A 3) Only possible with ZQV.<br>**----- End of picture text -----**<br>
**W**
**W.23**
**ATEX**
## **Maximum voltage**
**==> picture [513 x 453] intentionally omitted <==**
**----- Start of picture text -----**<br>
Range [1)] Certificate No. Rated Rated Rated current Nominal Maximum voltage (V)<br>voltage current with QV cross-section (letters refer to the above diagrams)<br>W … / V / A / A / mm² A C D E F G H I<br>WDU 95N/120N KEMA 98ATEX1683 U 880 243 243 120 880 -- 880 880 -- -- --<br>WDU 120/150 KEMA 98ATEX1686 U 1100 234 234 120 1100 -- -- 1100 1100 -- -- --<br>WDU 240 KEMA 01ATEX2186 U 1100 350 270 240 -- -- -- -- -- -- -- --<br>WDU 4 SL SIRA 02ATEX3242 U 275 28 28 4 275 275 176 275 275 176 176 --<br>WDU 6 SL SIRA 02ATEX3242 U 275 36 36 6 275 275 176 275 275 176 176 --<br>WDU 10 SL SIRA 02ATEX3242 U 275 50 50 10 275 275 176 275 275 176 176 --<br>Z …<br>ZDK 2.5/1.5 KEMA 97ATEX4677 U 275 18 18 2.5 275 275 275 275 275 275 -- --<br>ZDK 2.5/1.5V KEMA 97ATEX4677 U 420 20 19 2.5 275 275 275 275 275 275 -- --<br>ZDK 2.5/1.5NDU KEMA 97ATEX4677 U 275 20 20 2.5 275 275 275 275 275 275 -- --<br>ZDK 2.5/1.5NPE KEMA 97ATEX4677 U 275 20 20 2.5 275 275 275 275 275 275 -- --<br>ZDK 2.5/1.5DU-PE KEMA 97ATEX4677 U 275 20 20 2.5 275 275 275 275 275 275 -- --<br>ZDK 2.5-2 KEMA 97ATEX4677 U 550 20 18 2.5 440 440 275 440 440 275 -- --<br>ZDK 2.5-2V KEMA 97ATEX4677 U 550 22 18 2.5 440 440 275 440 440 275 -- --<br>ZDK 2.5-2DU-PE KEMA 97ATEX4677 U 550 20 18 2.5 440 440 275 440 440 275 -- --<br>ZDK 2.5/3AN KEMA 06ATEX0271U 550 21.5 21 2.5 275 275 275 275 275 -- -- --<br>ZDK 2.5/3AN V KEMA 06ATEX0271U 550 21 18.5 2.5 275 275 275 275 275 -- -- --<br>ZDK 2.5/3AN DU-PE KEMA 06ATEX0271U 550 21 21 2.5 275 275 275 275 275 -- -- --<br>ZDU 1.5 KEMA 01ATEX2106 U 550 15 15 1.5 275 275 176 275 275 176 176 --<br>ZDU 1.5/3AN KEMA 01ATEX2106 U 550 15 15 1.5 275 275 176 275 275 176 176 --<br>ZDU 1.5/4AN KEMA 01ATEX2106 U 550 15 15 1.5 275 275 176 275 275 176 176 --<br>ZDU 2.5 KEMA 97ATEX2521 U 550 21 21 2.5 275 275 275 275 275 275 60 --<br>ZDU 2.5/3AN KEMA 97ATEX2521 U 550 21 21 2.5 275 275 275 275 275 275 -- --<br>ZDU 2.5/4AN KEMA 97ATEX2521 U 550 21 21 2.5 275 275 275 275 275 275 -- --<br>ZDU 2.5N KEMA 06ATEX0271U 550 20.5 19 2.5 440 550 275 440 440 -- -- --<br>ZDU 2.5N/3AN KEMA 06ATEX0271U 550 21.5 21 2.5 440 550 275 440 440 -- -- --<br>ZDU 2.5N/4AN KEMA 06ATEX0271U 550 21 20 2.5 440 550 275 440 440 -- -- --<br>ZDU 4 KEMA 97ATEX2521 U 550 28 28 4 275 275 275 275 275 275 -- --<br>ZDU 4/3AN KEMA 00ATEX2107 U 550 28 28 4 550 550 275 -- -- -- -- --<br>ZDU 4/4AN KEMA 00ATEX2107 U 550 28 28 4 550 550 275 -- -- -- -- --<br>ZDU 6 KEMA 97ATEX2521 U 550 36 36 6 275 275 275 275 275 275 -- --<br>ZDU 6/3AN KEMA 00ATEX2107 U 550 36 36 6 550 550 275 -- -- -- -- --<br>ZDU 10 KEMA 99ATEX5514 U 550 50 50 10 550 -- -- -- -- -- -- --<br>ZDU 10/3AN KEMA 00ATEX2107 U 550 50 50 10 550 550 -- -- -- -- -- --<br>ZDU 16 KEMA 99ATEX5514 U 550 66 66 16 550 -- -- -- -- -- -- --<br>ZDU 35 KEMA 00ATEX2107 U 690 109 100 35 550 550 -- 550 550 -- -- --<br>ZDU 2.5-2/2AN KEMA 97ATEX4677 U 550 21 20 2.5 440 440 275 440 -- 275 176<br>ZDU 2.5-2/3AN KEMA 97ATEX4677 U 550 21 21 2.5 440 440 275 440 -- 275 176 --<br>ZDU 2.5-2/4AN KEMA 97ATEX4677 U 550 21 21 2.5 440 440 275 440 -- 275 176 --<br>ZDU 4-2/2AN KEMA 97ATEX4677 U 550 28 26 4 440 440 275 440 -- 275 110 --<br>ZDU 4-2/3AN KEMA 97ATEX4677 U 550 28 26 4 440 440 275 440 -- 275 110 --<br>ZDU 4-2/4AN KEMA 97ATEX4677 U 550 28 26 4 440 440 275 440 -- 275 110 --<br>ZDU 6-2/2AN KEMA 97ATEX4677 U 550 36 30 6 440 440 110 440 -- 110 -- --<br>ZDU 6-2/3AN KEMA 97ATEX4677 U 550 36 36 6 440 440 110 440 -- 110 -- --<br>ZDUA 2.5-2 KEMA 97ATEX4678 U 275 20 19 2.5 275 275 110 275 275 110 -- --<br> 1) Please refer to the catalogue and the certificate for details of precisely which article is approved.<br>**----- End of picture text -----**<br>
**W**
**W.24**
**Contents**
## Index
## **Index**
|Index Type / Index Order No.|X.2|
|---|---|
|Addresses worldwide|X.28|
**X**
**X.1**
**X**
|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|**A**|||AH 46 SAKG46<br>AH 46 SAKG46|0326960000<br>0326960000|I.17<br>A.46|AP DK4<br>AP DK4|0359260000<br>0359260000|A.54<br>B.10|AP SAK2.5/35 + AST3+4<br>AP SAK2.5/35 BL|0460560000<br>0460580000|I.6<br>I.6|
|AD 250|0634100000|I.18|AH 46 SAKG46|0326960000|A.47|AP DK4|0359260000|A.50|AP SAK2.5/35 DB|0460490000|I.6|
|AD 3 SAK10|0178500000|I.17|AK 95|0364200000|H.5|AP DK4|0359260000|B.56|AP SAK2.5L KRG|0309220000|I.4|
|AD 3 SAK16|0297800000|B.4|AKA 2.5|0300720000|E.12|AP DK4|0359260000|I.6|AP SAK2.5L KRG|0309220000|B.45|
|AD 3 SAK16|0297800000|I.17|AKA 2.5 BL|0300770000|E.12|AP DK4 BL|0359280000|A.12|AP SAK2.5L KRG|0309220000|I.6|
|AD 3 SAK2.5|0297900000|B.2|AKE 2.5|1303360000|E.4|AP DK4 BL|0359280000|B.38|AP SAK2.5L KRG BL|0309270000|I.6|
|AD 3 SAK2.5|0297900000|A.12|AKE 4|0380260000|E.5|AP DK4 BL|0359280000|I.6|AP SAK2.5L KRG BL|0309270000|B.45|
|AD 3 SAK2.5<br>AD 3 SAK2.5<br>AD 3 SAK2.5<br>AD 3 SAK35|0297900000<br>0297900000<br>0297900000<br>0273400000|C.2<br>I.17<br>A.2<br>B.4|AKE 4 MS<br>AKKU DMS 3<br>AKZ 1.5<br>AKZ 1.5 BL|0211200000<br>9007450000<br>0340460000<br>0340480000|E.4<br>J.10<br>E.2<br>E.2|AP DK4 BL<br>AP DK4/380 Q<br>AP DK4/380 Q<br>AP DK4Q|0359280000<br>0438560000<br>0438560000<br>1397160000|B.10<br>I.4<br>I.6<br>B.11|AP SAK35 KRG<br>AP SAK35 KRG<br>AP SAK35 KRG<br>AP SAK35 KRG|0303620000<br>0303620000<br>0303620000<br>0303620000|I.6<br>I.4<br>B.8<br>B.9|
|AD 3 SAK35|0273400000|I.17|AKZ 1.5L VS|0340160000|E.10|AP DK4Q|1397160000|A.12|AP SAK35 KRG|0303620000|A.9|
|AD 3 SAK4|0297600000|I.17|AKZ 2.5|0697160000|E.2|AP DK4Q|1397160000|A.13|AP SAK35 KRG/BL|0303670000|B.8|
|AD 3 SAK6N|0297700000|I.17|AKZ 2.5 BL|0697180000|E.2|AP DK4Q|1397160000|B.10|AP SAK35 KRG/BL|0303670000|B.9|
|AD 3 SAK70|0344300000|B.9|AKZ 2.5 K SW U/V 1X1|0108960000|E.13|AP DK4Q|1397160000|B.34|AP SAK35 KRG/BL|0303670000|A.9|
|AD 3 SAK70|0344300000|A.6|AKZ 4|0294360000|E.3|AP DK4Q|1397160000|I.6|AP SAK35 KRG/BL|0303670000|I.6|
|AD 3 SAK70|0344300000|I.17|AKZ 4 BL|0294380000|E.3|AP DK4Q|1397160000|A.34|AP SAK35/TW SAK16|0303660000|B.5|
|AD 3 WSD SAKG54 HP/DBR|0264900000|I.17|AKZ 4 LL VS|0346460000|E.11|AP DK4Q BL|1397180000|I.6|AP SAK35/TW SAK16|0303660000|I.6|
|AD 4 AKZ4|0303400000|E.10|AKZ 4 S WA 2X2.8|0324460000|E.9|AP DK4Q BL|1397180000|A.12|AP SAK35/TW SAK16|0303660000|C.4|
|AD 4 AKZ4|0303400000|B.39|AKZ 4 SF SE 6.3/2.8|0158760000|E.9|AP DK4Q BL|1397180000|B.10|AP SAK35/TW SAK16|0303660000|I.4|
|AD 4 AKZ4|0303400000|E.12|AKZ 4 SS SE 6.3/2.8|0324560000|E.8|AP DK4Q BL|1397180000|B.11|AP SAK35/TW SAK16|0303660000|A.4|
|AD 4 AKZ4|0303400000|E.11|AKZ 4 SS WA 2X2.8|0362460000|E.8|AP DK4Q BL|1397180000|A.13|AP SAK35/TW SAK16|0303660000|A.5|
|AD 4 AKZ4|0303400000|B.45|AKZ 4 SW 1X1|0445860000|E.13|AP DK4S|0631360000|I.6|AP SAK35/TW SAK16|0303660000|B.4|
|AD 4 AKZ4|0303400000|B.11|AKZ 4L SL VS|0334860000|E.10|AP DK4S|0631360000|A.38|AP SAK35/TW SAK16 BL|0303680000|B.7|
|AD 4 AKZ4|0303400000|A.7|AKZ 4L SL VS KRG|0334820000|E.12|AP DK4S|0631360000|B.37|AP SAK35/TW SAK16 BL|0303680000|C.4|
|AD 4 AKZ4|0303400000|A.40|AP DK4Q DB|0631300000|I.6|AP DK4S|0631360000|A.39|AP SAK35/TW SAK16 BL|0303680000|I.6|
|AD 4 AKZ4|0303400000|I.17|AP 100 GR|1773410000|I.6|AP DK4S BL|0631380000|I.6|AP SAK35/TW SAK16 BL|0303680000|B.5|
|AD 4 AKZ4|0303400000|A.13|AP 110 GR|1790080000|I.6|AP DKIT4|0635060000|I.6|AP SAK35/TW SAK16 BL|0303680000|A.5|
|AD 4 AKZ4|0303400000|B.6|AP 2 DSG1.5T|2119490000|I.6|AP DKT4 PA|0687560000|B.17|AP SAK35/TW SAK16 BL|0303680000|A.4|
|AD 4 SAK10|0178600000|C.3|AP 70 SAK70 KRG|0340920000|I.6|AP DKT4 PA|0687560000|B.61|AP SAK35/TW SAK16 BL|0303680000|B.4|
|AD 4 SAK10|0178600000|I.17|AP 70 SAK70 KRG|0340920000|B.9|AP DKT4 PA|0687560000|I.6|AP SAK35/TW SAK16 GE|2076910000|I.6|
|AD 4 SAK10|0178600000|B.7|AP 70 SAK70 KRG|0340920000|I.4|AP DKT4 PA|0687560000|A.19|AP SAK4 KRG M.FU|0460020000|I.6|
|AD 4 SAK10|0178600000|A.8|AP ADK1|0476260000|I.6|AP DKT4 PA|0687560000|A.56|AP SAK4-10|0117960000|A.38|
|AD 4 SAK10|0178600000|A.3|AP ADK1|0476260000|E.11|AP DLD2.5|1317660000|I.6|AP SAK4-10|0117960000|A.37|
|AD 4 SAK10|0178600000|B.3|AP AKA2.5|0162520000|I.6|AP DLD2.5 BL|1317680000|I.6|AP SAK4-10|0117960000|A.3|
|AD 4 SAK16|0518200000|B.7|AP AKA2.5|0162520000|E.12|AP DLD2.5 DB|1784210000|I.6|AP SAK4-10|0117960000|B.3|
|AD 4 SAK16|0518200000|I.17|AP AKA2.5 KRG/BL|0162570000|E.12|AP DLD2.5/PE|1595960000|I.6|AP SAK4-10|0117960000|B.37|
|AD 4 SAK16|0518200000|C.3|AP AKA2.5 KRG/BL|0162570000|I.6|AP DLD2.5/PE DB|1783800000|I.6|AP SAK4-10|0117960000|B.44|
|AD 4 SAK16|0518200000|A.4|AP AKZ1.5|0340560000|E.2|AP DLI2.5|1313260000|I.6|AP SAK4-10|0117960000|C.2|
|AD 4 SAK16|0518200000|A.9|AP AKZ1.5|0340560000|I.4|AP DLI2.5 DB|1783550000|I.6|AP SAK4-10|0117960000|C.3|
|AD 4 SAK35|0178700000|C.4|AP AKZ1.5|0340560000|I.6|AP DSK1.5|0532960000|I.6|AP SAK4-10|0117960000|C.4|
|AD 4 SAK35|0178700000|I.17|AP AKZ1.5 BL|0340580000|E.2|AP DUSA4/35|0401360000|I.6|AP SAK4-10|0117960000|C.5|
|AD 4 SAK35|0178700000|A.9|AP AKZ1.5 BL|0340580000|I.6|AP KDKS1 1.5|9503330000|I.6|AP SAK4-10|0117960000|I.6|
|AD 4 SAK35|0178700000|B.5|AP AKZ1.5W|0329660000|E.10|AP KDKS1 1.5 DB|9532470000|I.6|AP SAK4-10 BL|0117980000|C.3|
|AD 4 SAK35|0178700000|A.5|AP AKZ1.5W|0329660000|I.6|AP KDKS1 EN|9503340000|I.6|AP SAK4-10 BL|0117980000|C.5|
|AD 4 SAK35|0178700000|A.4|AP AKZ1.5W|0329660000|I.4|AP KDKS1 EN|9503340000|C.7|AP SAK4-10 BL|0117980000|C.4|
|AD 4 SAK35|0178700000|B.8|AP AKZ2.5|0697360000|I.6|AP KSKM|9509630000|I.6|AP SAK4-10 BL|0117980000|C.2|
|AD 4 SAK35N|0576700000|A.9|AP AKZ2.5|0697360000|E.2|AP MAK2.5|1615280000|I.6|AP SAK4-10 BL|0117980000|B.3|
|AD 4 SAK35N|0576700000|B.5|AP AKZ2.5 BL|0697380000|I.6|AP MAK2.5 DB|7917000000|I.6|AP SAK4-10 BL|0117980000|I.6|
|AD 4 SAK35N|0576700000|I.17|AP AKZ2.5 BL|0697380000|E.2|AP OSC 10/16|9154850000|I.6|AP SAK4-10 BL|0117980000|A.3|
|AD 4 SAK35N|0576700000|A.5|AP AKZ2.5K|0697260000|E.13|AP OSC 4|9154860000|I.6|AP SAK4-10 DB|0105100000|I.6|
|AD 4 SAK35N|0576700000|B.9|AP AKZ2.5K|0697260000|I.6|AP PPT/35|3835120000|I.6|AP SAK4-10 GE|2076890000|I.6|
|AD 4 SAK4|0285300000|C.4|AP AKZ4|0294460000|I.6|AP PPT/35|3835120000|D.9|AP SAK4-10 GR 7042|1853970000|I.6|
|AD 4 SAK4|0285300000|A.3|AP AKZ4|0294460000|E.8|AP RSF1 KRG|0270420000|I.6|AP SAK4-10 I|0117910000|I.6|
|AD 4 SAK4|0285300000|B.3|AP AKZ4|0294460000|E.9|AP RSF2 KRG|0301420000|I.6|AP SAK4-10 KRG|0117920000|I.4|
|AD 4 SAK4|0285300000|B.6|AP AKZ4|0294460000|I.4|AP RSF3|0270460000|I.6|AP SAK4-10 KRG|0117920000|I.6|
|AD 4 SAK4|0285300000|C.5|AP AKZ4|0294460000|E.11|AP RSF3|0270460000|A.11|AP SAK4-10 KRG|0117920000|A.7|
|AD 4 SAK4|0285300000|I.17|AP AKZ4|0294460000|E.13|AP RSF3|0270460000|B.28|AP SAK4-10 KRG|0117920000|A.20|
|AD 4 SAK4|0285300000|A.7|AP AKZ4|0294460000|E.12|AP RV|4145220000|I.6|AP SAK4-10 KRG|0117920000|B.44|
|AD 4 SAK4|0285300000|C.2|AP AKZ4|0294460000|E.10|AP SAK16|0271160000|I.4|AP SAK4-10 KRG|0117920000|B.7|
|AD 4 SAK6N|0196600000|A.8|AP AKZ4|0294460000|E.3|AP SAK16|0271160000|I.6|AP SAK4-10 KRG|0117920000|B.19|
|AD 4 SAK6N|0196600000|B.3|AP AKZ4 BL|0294480000|I.6|AP SAK16|0271160000|B.4|AP SAK4-10 KRG|0117920000|B.6|
|AD 4 SAK6N|0196600000|C.3|AP AKZ4 BL|0294480000|E.3|AP SAK16|0271160000|A.4|AP SAK4-10 KRG|0117920000|A.8|
|AD 4 SAK6N|0196600000|I.17|AP AKZ4 GE|2077070000|I.6|AP SAK16|0271160000|C.3|AP SAK4-10 KRG/BL|0117970000|B.19|
|AD 4 SAK6N|0196600000|A.3|AP AKZ4 KRG|0294420000|I.6|AP SAK16 BL|0271180000|C.3|AP SAK4-10 KRG/BL|0117970000|A.8|
|AD 4 SAK6N|0196600000|B.7|AP AKZ4 KRG|0294420000|I.4|AP SAK16 BL|0271180000|I.6|AP SAK4-10 KRG/BL|0117970000|A.7|
|AD 4 WSD SAKG28 HP/DBR|0263100000|I.17|AP ASK1|0380360000|C.7|AP SAK16 BL|0271180000|A.4|AP SAK4-10 KRG/BL|0117970000|B.44|
|AD 4 WSD SAKG32 HP/DBR|0283100000|I.17|AP ASK1|0380360000|I.6|AP SAK16 BL|0271180000|B.4|AP SAK4-10 KRG/BL|0117970000|B.7|
|AD 4 WSD SAKG40 HP/DBR|0263200000|I.17|AP ASK1 BL|0380380000|I.6|AP SAK16 GE|2076900000|I.6|AP SAK4-10 KRG/BL|0117970000|I.6|
|AD 4 WSD SAKG46 HP/DBR|0263300000|I.17|AP ASK1 DB|1753320000|I.6|AP SAK16 KRG|0271120000|I.6|AP SAK4-10 KRG/BL|0117970000|B.6|
|AD 4 WSD SAKG54 HP/DBR|0261100000|I.17|AP ASK1 OR|0105360000|I.6|AP SAK16 KRG|0271120000|B.7|AP SAK4-10 KRG/BL|0117970000|A.20|
|ADAPTER ALU STI-S|1762440000|K.25|AP ASK1 RT|0380350000|I.6|AP SAK16 KRG|0271120000|A.9|AP SAK4-10 KRG/DB|0177600000|I.6|
|ADAPTER ALU STI-S|1762440000|K.24|AP AST1+5|0266460000|I.6|AP SAK16 KRG|0271120000|I.4|AP SAK4-10 OR|0105160000|I.6|
|ADK 1/1.5|0303860000|E.11|AP AST1+5 DB|0266400000|B.36|AP SAK2.5|0279560000|A.2|AP SAK4-10 RT|0117900000|I.6|
|ADL|0210800000|I.18|AP AST1+5 DB|0266400000|A.37|AP SAK2.5|0279560000|B.38|AP SAK70/35|0340960000|A.6|
|ADP 1/HP1 1M|0485200000|I.16|AP AST1+5 DB|0266400000|A.36|AP SAK2.5|0279560000|B.39|AP SAK70/35|0340960000|I.6|
|ADP 2/HP2 1M|0485300000|I.16|AP AST1+5 DB|0266400000|I.6|AP SAK2.5|0279560000|A.40|AP SAK70/35|0340960000|I.4|
|ADP 2/HP2 1M|0485300000|A.11|AP AST1+5 KRG|0266420000|I.6|AP SAK2.5|0279560000|I.6|AP SAK95 KRG|0550920000|I.4|
|ADP 3/HP3 1M|0485400000|A.10|AP AST1+5 KRG|0266420000|I.4|AP SAK2.5|0279560000|B.34|AP SAK95 KRG|0550920000|I.6|
|ADP 3/HP3 1M|0485400000|I.16|AP AST1+5 KRG|0266420000|B.43|AP SAK2.5|0279560000|B.2|AP SAK95 KRG|0550920000|B.9|
|ADP 4/1000|1430760000|I.16|AP AST1+5 KRG|0266420000|B.42|AP SAK2.5 BL|0279580000|I.6|AP SAK95 KRG|0550920000|A.10|
|ADP 4/300|1378160000|I.16|AP AST3+4 KRG|0298120000|A.36|AP SAK2.5 BL|0279580000|B.39|AP SAK95 KRG/BL|0550970000|I.6|
|AH 28 SAKG28|0326660000|I.17|AP AST3+4 KRG|0298120000|B.43|AP SAK2.5 BL|0279580000|B.2|AP SAK95 KRG/BL|0550970000|A.10|
|AH 28 SAKG28|0326660000|B.48|AP AST3+4 KRG|0298120000|B.42|AP SAK2.5 BL|0279580000|A.2|AP SAKA KRG|0134220000|B.30|
|AH 28 SAKG28|0326660000|B.46|AP AST3+4 KRG|0298120000|I.4|AP SAK2.5 BL|0279580000|A.40|AP SAKA KRG|0134220000|I.6|
|AH 28 SAKG28|0326660000|B.47|AP AST3+4 KRG|0298120000|I.6|AP SAK2.5 GE|0279500000|I.6|AP SAKA KRG|0134220000|I.4|
|AH 32 SAKG32|0326760000|I.17|AP AST3+4/35 GE|2077060000|I.6|AP SAK2.5 KRG|0279520000|I.6|AP SAKB/C/T BE|0146760000|I.6|
|AH 32 SAKG32|0326760000|A.44|AP DK4|0359260000|A.12|AP SAK2.5 KRG|0279520000|B.6|AP SAKB/C/T BE|4140450000|I.6|
|AH 32 SAKG32|0326760000|A.42|AP DK4|0359260000|B.38|AP SAK2.5 KRG|0279520000|I.4|AP SAKB/C/T KRG|0146720000|I.6|
|AH 32 SAKG32|0326760000|A.43|AP DK4|0359260000|A.56|AP SAK2.5 KRG|0279520000|A.7|AP SAKB/C/T KRG|0146720000|B.32|
|AH 32 SAKG32|0326760000|B.48|AP DK4|0359260000|A.51|AP SAK2.5 KRG BL|0279570000|A.7|AP SAKB/C/T KRG|0146720000|I.4|
|AH 32 SAKG32|0326760000|B.50|AP DK4|0359260000|B.61|AP SAK2.5 KRG BL|0279570000|I.6|AP SAKB/C/T KRG|0146720000|A.20|
|AH 32 SAKG32|0326760000|B.49|AP DK4|0359260000|B.59|AP SAK2.5 KRG BL|0279570000|B.6|AP SAKB/C/T KRG|0146720000|B.31|
|AH 40 SAKG40|0326860000|A.45|AP DK4|0359260000|B.58|AP SAK2.5 KRS|0279530000|I.4|AP SAKB/C/T KRG|0146720000|A.32|
|AH 40 SAKG40|0326860000|B.51|AP DK4|0359260000|B.57|AP SAK2.5 OR|0279540000|I.6|AP SAKB/C/T KRG|0146720000|A.33|
|AH 40 SAKG40|0326860000|I.17|AP DK4|0359260000|A.53|AP SAK2.5/35|2144900000|I.6|AP SAKB/C/T KRG|0146720000|B.30|
|AH 40 SAKG40|0326860000|A.46|AP DK4|0359260000|A.52|AP SAK2.5/35 + AST3+4|0460560000|C.2|AP SAKB/C/T1 DB|4173520000|I.6|
|AH 40 SAKG40|0326860000|B.50|AP DK4|0359260000|A.55|AP SAK2.5/35 + AST3+4|0460560000|A.37|AP SAKB-C-T I|0146710000|B.19|
|AH 46 SAKG46|0326960000|B.52|AP DK4|0359260000|B.60|AP SAK2.5/35 + AST3+4|0460560000|B.36|AP SAKD2.5N|0150960000|A.2|
**X.2**
|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|AP SAKD2.5N|0150960000|I.6|BFSC M2.5X14 SAKD2.5N|0266800000|B.60|BK 2/E|7906040000|F.6|DEK 5 FS 701-750|0473560701|K.7|
|AP SAKD2.5N|0150960000|I.4|BFSC M2.5X14 SAKD2.5N|0266800000|A.54|BK 3 CRN|0624920000|F.5|DEK 5 FS 751-800|0473560751|K.7|
|AP SAKD2.5N|0150960000|B.2|BFSC M2.5X18 PA/RT|0303300000|E.11|BK 3/E|7906060000|F.6|DEK 5 FS 801-850|0473560801|K.7|
|AP SAKD2.5N BL|0150980000|I.6|BFSC M2.5X18 PA/RT|0303300000|B.11|BK 4 CRN|0625120000|F.5|DEK 5 FS 851-900|0473560851|K.7|
|AP SAKD2.5N BL|0150980000|A.2|BFSC M2.5X18 PA/RT|0303300000|I.17|BK 4/E|7906080000|F.6|DEK 5 FS 901-950|0473560901|K.7|
|AP SAKD2.5N BL|0150980000|B.2|BFSC M2.5X18 PA/RT|0303300000|A.12|BK 6 CRN|0625220000|F.5|DEK 5 FS 951-999|0473560951|K.7|
|AP SAKH 4EX|0408730000|I.6|BFSC M2.5X18 PA/RT|0303300000|E.12|BK 6/E|7906090000|F.6|DEK 5 FSZ 1-10|0460660001|K.7|
|AP SAKH6/10 EP/SW|0131700000|D.7|BFSC M2.5X18 PA/RT|0303300000|A.13|BS 25 IH/BL SAKT1|0335400000|I.21|DEK 5 FSZ 11-20|0460660011|K.7|
|AP SAKH6/10 EP/SW<br>AP SAKH6/10 EP/SW<br>AP SAKH6/10 KRG<br>AP SAKH6/10 KRS|0131700000<br>0131700000<br>0131720000<br>0131730000|I.6<br>D.6<br>I.6<br>I.4|BFSC M2.5X18 PA/RT<br>BFSC M3X22 PA/RT<br>BFSC M3X22 PA/RT<br>BFSC M3X22 PA/RT|0303300000<br>0128900000<br>0128900000<br>0128900000|E.10<br>A.7<br>I.17<br>A.8|BS 25 IH/GE SAKT1<br>BS 25 IH/GN SAKT1<br>BS 25 IH/GR SAKT1<br>BS 25 IH/RT SAKT1|0335700000<br>0335600000<br>0335300000<br>0335500000|I.21<br>I.21<br>I.21<br>I.21|DEK 5 FSZ 18,20,...32<br>DEK 5 FSZ 2,4,6...16<br>DEK 5 FSZ 21-30<br>DEK 5 FSZ 31-40|0582360018<br>0582360002<br>0460660021<br>0460660031|K.7<br>K.7<br>K.7<br>K.7|
|AP SAKK4/10 KER/WS|9502630000|I.6|BFSC M3X22 PA/RT|0128900000|C.5|BS 25 IH/SW SAKT1|0335200000|I.21|DEK 5 FSZ 41-50|0460660041|K.7|
|AP SAKK4/10 KER/WS|9502630000|D.3|BFSC M3X22 PA/RT|0128900000|A.9|BS 25 IH/VI SAKT1|0335800000|I.21|DEK 5 FSZ 51-60|0460660051|K.7|
|AP SAKK4/10 KER/WS|9502630000|D.2|BFSC M3X22 PA/RT|0128900000|A.3|BS 25 O.IH SAKT1|0334700000|B.32|DEK 5 FSZ 61-70|0460660061|K.7|
|AP SAKR BE|0211360000|A.18|BFSC M3X22 PA/RT|0128900000|B.2|BS 25 O.IH SAKT1|0334700000|A.32|DEK 5 FSZ 71-80|0460660071|K.7|
|AP SAKR BE|0211360000|B.16|BFSC M3X22 PA/RT|0128900000|A.40|BS 25 O.IH SAKT1|0334700000|I.21|DEK 5 FSZ 81-90|0460660081|K.7|
|AP SAKR BE|0211360000|I.4|BFSC M3X22 PA/RT|0128900000|C.4|BS 25 O.IH SAKT1|0334700000|B.31|DEK 5 FSZ 91-100|0460660091|K.7|
|AP SAKR BE|0211360000|I.6|BFSC M3X22 PA/RT|0128900000|B.45|BS 25 O.IH SAKT1|0334700000|A.33|DEK 5 FW 1,3,5,...99|1358460000|K.7|
|AP SAKR BE|0211360000|B.39|BFSC M3X22 PA/RT|0128900000|B.39|BS 35/WSH 2|1760720000|G.7|DEK 5 FW 101-150|0473460101|K.7|
|AP SAKR BE|0211360000|E.3|BFSC M3X22 PA/RT|0128900000|A.4|BS 35II KLBUE HOLDER|1723800000|G.10|DEK 5 FW 10-500|0132660010|K.7|
|AP SAKR BE|0211360000|B.41|BFSC M3X22 PA/RT|0128900000|B.4|BS 35II KLBUE2X3-8/2X2-6|1768020000|G.10|DEK 5 FW 1-50|0473460001|K.7|
|AP SAKR BE|0211360000|B.40|BFSC M3X22 PA/RT|0128900000|B.3|BS 35II KLBUE3-8|1723810000|G.10|DEK 5 FW 151-200|0473460151|K.7|
|AP SAKR BE RS-SET|1820200000|I.6|BFSC M3X22 PA/RT|0128900000|C.3|BS 35II KLBUE3-8/2X2-6|1749430000|G.10|DEK 5 FW 2,4,...100|1358560000|K.7|
|AP SAKR BL|0211380000|I.6|BFSC M3X22 PA/RT|0128900000|A.2|BS 35II/KLBUE 4-13.5|1723820000|G.10|DEK 5 FW 201-250|0473460201|K.7|
|AP SAKR BL|0211380000|B.40|BFSC M3X22 PA/RT|0128900000|C.2|BST 2 BEZEICHNUNGSSTR.|1287700000|I.17|DEK 5 FW 251-300|0473460251|K.7|
|AP SAKR BL|0211380000|B.41|BFSC M3X22 PA/RT|0128900000|B.7|BSTB 28/12 BK U 1-12|0198800000|F.5|DEK 5 FW 301-350|0473460301|K.7|
|AP SAKR BL|0211380000|B.16|BFSC M3X22 PA/RT|0128900000|B.6|BSTB 28/12 BK U 1-12|0198800000|F.6|DEK 5 FW 351-400|0473460351|K.7|
|AP SAKR BL|0211380000|A.18|BFSC M3X22 SAKT4|1319900000|A.33|BSTB 28/12 MK U 1-12|0245900000|F.6|DEK 5 FW 401-450|0473460401|K.7|
|AP SAKR KRG|0211320000|B.18|BFSC M3X22 SAKT4|1319900000|B.32|BSTB 28/12 MK U 1-12|0245900000|F.2|DEK 5 FW 451-500|0473460451|K.7|
|AP SAKR KRG|0211320000|I.6|BFSC M3X25|0292500000|A.3|BSTB 28/12/6,35 O 1-12|0278500000|F.2|DEK 5 FW 501-550|0473460501|K.7|
|AP SAKS1+3 KRG|0191320000|B.22|BFSC M3X25|0292500000|C.2|BSTB 28/12/6,35 U 1-12|0245700000|F.2|DEK 5 FW 51-100|0473460051|K.7|
|AP SAKS1+3 KRG|0191320000|I.4|BFSC M3X25|0292500000|C.3|BSTB 28/16 MK O 1-16|0278700000|F.3|DEK 5 FW 551-600|0473460551|K.7|
|AP SAKS1+3 KRG|0191320000|A.24|BFSC M3X25|0292500000|A.7|BSTB 28/16 MK U 1-16|0262200000|F.3|DEK 5 FW 601-650|0473460601|K.7|
|AP SAKS1+3 KRG|0191320000|B.23|BFSC M3X25|0292500000|I.12|BSTB 28/2 BK U 1-2|0203600000|F.5|DEK 5 FW 651-700|0473460651|K.7|
|AP SAKS1+3 KRG|0191320000|A.25|BFSC M3X25|0292500000|C.4|BSTB 28/2 BK U 1-2|0203600000|F.6|DEK 5 FW 701-750|0473460701|K.7|
|AP SAKS1+3 KRG|0191320000|I.6|BFSC M3X25|0292500000|A.8|BSTB 28/4 BK U 1-4|0197300000|F.6|DEK 5 FW 751-800|0473460751|K.7|
|AP SAKS1+3 KRG/DB|0191300000|I.6|BFSC M3X25|0292500000|A.9|BSTB 28/4 BK U 1-4|0197300000|F.5|DEK 5 FW 801-850|0473460801|K.7|
|AP SAKT2 KRG|0329120000|I.6|BFSC M3X25|0292500000|I.10|BSTB 28/6 BK U 1-6|0197500000|F.6|DEK 5 FW 851-900|0473460851|K.7|
|AP SAKT2 KRG|0329120000|I.4|BFSC M3X25|0292500000|C.5|BSTB 28/6 BK U 1-6|0197500000|F.5|DEK 5 FW 901-950|0473460901|K.7|
|AP SAKT4 KRG|0244920000|I.6|BFSC M3X25|0292500000|B.7|BSTB 28/6 MK U 1-6|0290000000|F.6|DEK 5 FW 951-999|0473460951|K.7|
|AP ST5 PA/BE|0447260000|I.6|BFSC M3X25|0292500000|A.4|BSTB 28/6 MK U 1-6|0290000000|F.2|DEK 5 FW U1-PE1|0133161114|K.7|
|AP ST5 PPO/SW|0447240000|I.6|BFSC M3X25|0292500000|B.6|BSTB 28/8 MK U 1-8|0290200000|F.2|DEK 5 FW U2-PE2|0133161115|K.7|
|AP ST5 PPO/SW|0447240000|C.6|BFSC M3X25|0292500000|B.3|BSTB 28/8 MK U 1-8|0290200000|F.6|DEK 5 FW U3-PE3|0133161116|K.7|
|AP STA2.5 0.5MM|2012770000|I.6|BFSC M3X25|0292500000|B.4|BSTO 28/12 BK|0198700000|F.5|DEK 5 FW U4-PE4|0133161117|K.7|
|AP TAL|0212260000|I.6|BFSC M3X30|0296200000|B.28|BSTO 28/12 BK|0198700000|F.6|DEK 5 FW U5-PE5|0133161118|K.7|
|AP TOP4SF-FF|0483460000|I.4|BFSC M3X30|0296200000|A.11|BSTO 28/12 MK|0245800000|F.2|DEK 5 FW U6-PE6|0133161119|K.7|
|AP TOP4SF-FF|0483460000|I.6|BFSC M3X30|0296200000|I.10|BSTO 28/12 MK|0245800000|F.6|DEK 5 FW U7-PE7|0133161120|K.7|
|AP TW/SS.../35|1333200000|I.6|BFSC M3X35|0309800000|B.28|BSTO 28/12/6,35|0245600000|F.2|DEK 5 FW U8-PE8|0133161121|K.7|
|AP VLI1.5|1633260000|I.6|BFSC M3X35|0309800000|I.10|BSTO 28/16 MK 4/16|0262100000|F.3|DEK 5 FW U9-PE9|0133161122|K.7|
|AP VLI1.5 DB|1784150000|I.6|BFSC M3X7 STV1/5|0199700000|<br>I.9|BSTO 28/2 BK|0203500000|F.5|DEK 5 FW X10-Z10|0133261159|K.7|
|AP VLI1.5/PE|1633320000|I.6|BFSC M4X20|0362800000|B.19|BSTO 28/2 BK|0203500000|F.6|DEK 5 FW X1-Z1|0133261150|K.7|
|AP VLI1.5/PE DB|1784160000|I.6|BFSC M4X20|0362800000|A.20|BSTO 28/3 BK|0203700000|F.6|DEK 5 FW X2-Z2|0133261151|K.7|
|ASK 1/15|0376860000|E.6|BFSC M4X30|0267100000|A.9|BSTO 28/3 BK|0203700000|F.5|DEK 5 FW X3-Z3|0133261152|K.7|
|ASK 1/EN|0474560000|C.7|BFSC M4X30|0267100000|C.4|BSTO 28/4 BK|0197200000|F.5|DEK 5 FW X4-Z4|0133261153|K.7|
|ASK 1/EN LD 120K 230VDC|0225660000|C.7|BFSC M4X30|0267100000|B.30|BSTO 28/4 BK|0197200000|F.6|DEK 5 FW X5-Z5|0133261154|K.7|
|ASK 1/EN LD 15K 24VDC|0222760000|C.7|BFSC M4X30|0267100000|I.9|BSTO 28/4 MK3/4|0289300000|F.6|DEK 5 FW X6-Z6|0133261155|K.7|
|ASK 1/EN LD 1D 115VAC|0225560000|C.7|BFSC M4X30|0267100000|B.8|BSTO 28/4 MK3/4|0289300000|F.2|DEK 5 FW X7-Z7|0133261156|K.7|
|ASK 1/EN LD 1D 230VAC|0225760000|C.7|BFSC M4X30|0267100000|A.5|BSTO 28/6 BK|0197400000|F.5|DEK 5 FW X8-Z8|0133261157|K.7|
|ASK 1/EN LD 1D 24VAC|0222860000|C.7|BFSC M4X30|0267100000|I.10|BSTO 28/6 BK|0197400000|F.6|DEK 5 FW X9-Z9|0133261158|K.7|
|ASK 1/EN LD 1D 48VAC|0225360000|C.7|BFSC M4X30|0267100000|H.4|BSTO 28/6 MK|0289500000|F.2|DEK 5 FWZ 1,3,5-19|0235860000|K.7|
|ASK 1/EN LD 27K 48VDC|0225260000|C.7|BFSC M4X30|0267100000|B.5|BSTO 28/6 MK|0289500000|F.6|DEK 5 FWZ 1-10|0523060001|K.7|
|ASK 1/EN LD 33K 60VDC|0226460000|C.7|BFSC M4X30|0267100000|A.4|BSTO 28/8 MK3/8|0284700000|F.6|DEK 5 FWZ 11-20|0523060011|K.7|
|ASK 1/EN LD 56K 115VDC|0225460000|C.7|BFSC M4X30|0267100000|B.9|BSTO 28/8 MK3/8|0284700000|F.2|DEK 5 FWZ 1-9|1572000000|K.7|
|AST 1 6.3|0266360000|B.36|BFSC M4X30|0267100000|B.4|BTWZ KLBUE|1742630000|G.8|DEK 5 FWZ 2,4,6-20|0236160000|K.7|
|AST 1 6.3 KRG|0266320000|B.42|BFSC M4X32 PA/RT|0129100000|B.5|BUE SPX|9005450000|J.4|DEK 5 FWZ 21,23,25-39|0235960000|K.7|
|AST 1 6.3/2.8|0478260000|B.36|BFSC M4X32 PA/RT|0129100000|A.5|BZT 1 WS 10/5|1805490000|K.16|DEK 5 FWZ 21-30|0523060021|K.7|
|AST 1 6.3/2.8 KRG|0478220000|B.42|BFSC M4X32 PA/RT|0129100000|B.4|BZT 1 ZA WS 10/5|1805520000|K.16|DEK 5 FWZ 22,24,26-40|0236260000|K.7|
|AST 1/35 6.3|0664860000|A.36|BFSC M4X32 PA/RT|0129100000|B.9|BZT 2 WS 10/5|1805480000|K.16|DEK 5 FWZ 31-40|0523060031|K.7|
|AST 1/35 6.3/2.8|0699660000|A.36|BFSC M4X32 PA/RT|0129100000|A.9|BZT 2 ZA WS 10/5|1805530000|K.16|DEK 5 FWZ 41,43,45-59|0236060000|K.7|
|AST 3 6.3|0236760000|B.36|BFSC M4X32 PA/RT|0129100000|C.4||||DEK 5 FWZ 41-50|0523060041|K.7|
|AST 3 6.3 KRG<br>AST 3 6.3/2.8 KRG|0298020000<br>0442420000|B.42<br>B.42|BFSC M4X32 PA/RT<br>BFSC M4X32 PA/RT|0129100000<br>0129100000|B.8<br>A.4|**C**|||DEK 5 FWZ 42,44,46-60<br>DEK 5 FWZ 51-60|0236360000<br>0523060051|K.7<br>K.7|
|AST 3/35 6.3|0479360000|A.36|BFSC M4X32 PA/RT|0129100000|I.17|CleanUnit PrintJet II|1858950000|K.22|DEK 5 FWZ 61-70|0523060061|K.7|
|AST 3/35 6.3/2.8|0460360000|A.36|BFSC M4X35|0298900000|A.4|CTI 6|9006120000|J.35|DEK 5 FWZ 71-80|0523060071|K.7|
|AST 4 SF 6.3/2.8 KRG|0439120000|B.43|BFSC M4X35|0298900000|B.5|CTI 6 S|9006210000|J.35|DEK 5 FWZ 81-90|0523060081|K.7|
|AST 4/35 SF 6.3|0479460000|A.37|BFSC M4X35|0298900000|B.4||||DEK 5 FWZ 91-100|0523060091|K.7|
|AST 4/35 SF 6.3/2.8<br>AST 5 SF 6.3 KRG|0460460000<br>0334520000|A.37<br>B.43|BFSC M4X35<br>BFSC M4X35|0298900000<br>0298900000|A.5<br>B.8|**D**|||DEK 5 FWZ L1-EIK<br>DEK 5 FWZ L1-PE|0354361203<br>0354361187|K.7<br>K.7|
|AST 5 SF 6.3/2.8 KRG|0479220000|B.43|BFSC M4X35|0298900000|I.12|D 2 MK5/2 PA/NA|0244060000|F.4|DEK 5 FWZ U,V,W,N,PE|0558360000|K.7|
|AST 5/35 SF 6.3/2.8|0664960000|A.37|BFSC M4X9T|0103300000|A.26|D10 KS10 TP|0141800000|F.4|DEK 5 GE NEUTRAL|0473391687|K.7|
||||BFSC M4X9T|0103300000|B.24|D2 KS2 TP|0134500000|F.4|DEK 5 GN NEUTRAL|0473391688|K.7|
|**B**|||BFSC M4X9T<br>BFSC M4X9T|0103300000<br>0103300000|B.25<br>A.27|D4 KS4 TP<br>D6 KS6 TP|0140500000<br>0140800000|F.4<br>F.4|DEK 5 GR NEUTRAL<br>DEK 5 GS A|0473391691<br>0132961021|K.7<br>K.7|
|BAL 2|0181800000|J.11|BFSC M4X9T|0103300000|B.30|DEK 5 BL NEUTRAL|0473391693|K.7|DEK 5 GS B|0132961022|K.7|
|BEZ.-KARTE ADP|0566700000|I.16|BFSC M4X9T|0103300000|H.4|DEK 5 BR NEUTRAL|0473391692|K.7|DEK 5 GS C|0132961023|K.7|
|BFEH 1/WSH|1082400000|G.7|BFSC M4X9T|0103300000|<br>I.9|DEK 5 FS 101-150|0473560101|K.7|DEK 5 GS D|0132961024|K.7|
|BFSC M2.5X14 SAKD2.5N|0266800000|E.12|BFSC M5X45|0345600000|A.6|DEK 5 FS 1-50|0473560001|K.7|DEK 5 GS E|0132961025|K.7|
|BFSC M2.5X14 SAKD2.5N|0266800000|A.56|BFSC M5X45|0345600000|B.9|DEK 5 FS 151-200|0473560151|K.7|DEK 5 GS ERDE|0157261202|K.7|
|BFSC M2.5X14 SAKD2.5N|0266800000|A.55|BFSC M5X45|0345600000|I.9|DEK 5 FS 201-250|0473560201|K.7|DEK 5 GS ERDE IM KREIS|0157261203|K.7|
|BFSC M2.5X14 SAKD2.5N|0266800000|E.11|BFSC M5X45 PA/NA|0344400000|A.10|DEK 5 FS 251-300|0473560251|K.7|DEK 5 GS F|0132961026|K.7|
|BFSC M2.5X14 SAKD2.5N|0266800000|E.10|BFSC M5X45 PA/NA|0344400000|A.6|DEK 5 FS 301-350|0473560301|K.7|DEK 5 GS G|0132961027|K.7|
|BFSC M2.5X14 SAKD2.5N|0266800000|A.53|BFSC M5X45 PA/NA|0344400000|I.17|DEK 5 FS 351-400|0473560351|K.7|DEK 5 GS H|0132961028|K.7|
|BFSC M2.5X14 SAKD2.5N|0266800000|B.56|BFSC M5X45 PA/NA|0344400000|B.9|DEK 5 FS 401-450|0473560401|K.7|DEK 5 GS I|0132961029|K.7|
|BFSC M2.5X14 SAKD2.5N|0266800000|B.59|BFSC M5X8 Schlitz|0296700000|H.3|DEK 5 FS 451-500|0473560451|K.7|DEK 5 GS J|0132961030|K.7|
|BFSC M2.5X14 SAKD2.5N|0266800000|B.58|BIT E6.3 Z 0.6X3.5X39|9025570000|J.20|DEK 5 FS 501-550|0473560501|K.7|DEK 5 GS K|0132961031|K.7|
|BFSC M2.5X14 SAKD2.5N|0266800000|A.52|BIT E6.3 Z 0.8X4.0X39|9025590000|J.20|DEK 5 FS 51-100|0473560051|K.7|DEK 5 GS L|0132961032|K.7|
|BFSC M2.5X14 SAKD2.5N|0266800000|A.51|BK 12 CRN|0625320000|F.5|DEK 5 FS 551-600|0473560551|K.7|DEK 5 GS M|0132961033|K.7|
|BFSC M2.5X14 SAKD2.5N|0266800000|A.50|BK 12/E|7906100000|F.6|DEK 5 FS 601-650|0473560601|K.7|DEK 5 GS N|0132961034|K.7|
|BFSC M2.5X14 SAKD2.5N|0266800000|B.57|BK 2 CRN|0624720000|F.5|DEK 5 FS 651-700|0473560651|K.7|DEK 5 GS O|0132961035|K.7|
**X**
**X.3**
**X**
|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|DEK 5 GS P|0132961036|K.7|DEK 5 GW 176|0522660176|K.8|DEK 5 GW 86|0522660086|K.7|DEK 5/3,5 MC GW 1|1755280001|K.8|
|DEK 5 GS PE|0157261187|K.7|DEK 5 GW 177|0522660177|K.8|DEK 5 GW 87|0522660087|K.7|DEK 5/3,5 MC GW 2|1755280002|K.8|
|DEK 5 GS Q|0132961037|K.7|DEK 5 GW 178|0522660178|K.8|DEK 5 GW 88|0522660088|K.7|DEK 5/3,5 MC GW 3|1755280003|K.8|
|DEK 5 GS R|0132961038|K.7|DEK 5 GW 179|0522660179|K.8|DEK 5 GW 89|0522660089|K.7|DEK 5/3,5 MC GW 4|1755280004|K.8|
|DEK 5 GS S|0132961039|K.7|DEK 5 GW 18|0522660018|K.7|DEK 5 GW 9|0522660009|K.7|DEK 5/3,5 MC GW 5|1755280005|K.8|
|DEK 5 GS T|0132961040|K.7|DEK 5 GW 180|0522660180|K.8|DEK 5 GW 90|0522660090|K.7|DEK 5/3,5 MC GW 6|1755280006|K.8|
|DEK 5 GS U|0132961041|K.7|DEK 5 GW 181|0522660181|K.8|DEK 5 GW 91|0522660091|K.7|DEK 5/3,5 MC GW 7|1755280007|K.8|
|DEK 5 GS V|0132961042|K.7|DEK 5 GW 182|0522660182|K.8|DEK 5 GW 92|0522660092|K.7|DEK 5/3,5 MC GW 8|1755280008|K.8|
|DEK 5 GS W<br>DEK 5 GS X<br>DEK 5 GS Y<br>DEK 5 GS Z|0132961043<br>0132961044<br>0132961045<br>0132961046|K.7<br>K.7<br>K.7<br>K.7|DEK 5 GW 183<br>DEK 5 GW 184<br>DEK 5 GW 185<br>DEK 5 GW 186|0522660183<br>0522660184<br>0522660185<br>0522660186|K.8<br>K.8<br>K.8<br>K.8|DEK 5 GW 93<br>DEK 5 GW 94<br>DEK 5 GW 95<br>DEK 5 GW 96|0522660093<br>0522660094<br>0522660095<br>0522660096|K.7<br>K.7<br>K.7<br>K.7|DEK 5/3,5 MC GW 9<br>DEK 5/3,5 MC NEUTRAL<br>DEK 5/30 MC NEUTRAL<br>DEK 5/30 MC NEUTRAL|1755280009<br>1755270000<br>1951920000<br>1951920000|K.8<br>K.11<br>K.18<br>K.11|
|DEK 5 GW|0576260000|K.7|DEK 5 GW 187|0522660187|K.8|DEK 5 GW 97|0522660097|K.7|DEK 5/30 MC SDR|1025680000|K.11|
|DEK 5 GW -|0576261199|K.8|DEK 5 GW 188|0522660188|K.8|DEK 5 GW 98|0522660098|K.7|DEK 5/5 MC BEDRUCKT|1609810000|K.11|
|DEK 5 GW +|0576261198|K.8|DEK 5 GW 189|0522660189|K.8|DEK 5 GW 99|0522660099|K.7|DEK 5/5 MC-10 NEUT. BL|1609801693|K.11|
|DEK 5 GW 1|0522660001|K.7|DEK 5 GW 19|0522660019|K.7|DEK 5 GW A|0522761021|K.8|DEK 5/5 MC-10 NEUT. GE|1609801687|K.11|
|DEK 5 GW 10|0522660010|K.7|DEK 5 GW 190|0522660190|K.8|DEK 5 GW A KLEIN|0522861047|K.8|DEK 5/5 MC-10 NEUT. GN|1609801688|K.11|
|DEK 5 GW 100|0522660100|K.7|DEK 5 GW 191|0522660191|K.8|DEK 5 GW B|0522761022|K.8|DEK 5/5 MC-10 NEUT. GR|1609801691|K.11|
|DEK 5 GW 101|0522660101|K.7|DEK 5 GW 192|0522660192|K.8|DEK 5 GW B KLEIN|0522861048|K.8|DEK 5/5 MC-10 NEUT. RT|1609801686|K.11|
|DEK 5 GW 102|0522660102|K.7|DEK 5 GW 193|0522660193|K.8|DEK 5 GW BL/SW -|0576291741|K.8|DEK 5/5 MC-10 NEUT. WS|1609801044|K.11|
|DEK 5 GW 103|0522660103|K.7|DEK 5 GW 194|0522660194|K.8|DEK 5 GW C|0522761023|K.8|DEK 5/5 MC-10 NEUT. WS|1609801044|K.19|
|DEK 5 GW 104|0522660104|K.7|DEK 5 GW 195|0522660195|K.8|DEK 5 GW C KLEIN|0522861049|K.8|DEK 5/5 MC-10 NEUT. WS|1609801044|K.18|
|DEK 5 GW 105|0522660105|K.7|DEK 5 GW 196|0522660196|K.8|DEK 5 GW D|0522761024|K.8|DEK 5/5 MC-10 NEUT. WS|1609801044|K.17|
|DEK 5 GW 106|0522660106|K.7|DEK 5 GW 197|0522660197|K.8|DEK 5 GW D KLEIN|0522861050|K.8|DEK 5/5 MC-10 NEUT. WS|1609801044|K.16|
|DEK 5 GW 107|0522660107|K.7|DEK 5 GW 198|0522660198|K.8|DEK 5 GW E|0522761025|K.8|DEK 5/5 PLUS MC GE|1907520000|K.11|
|DEK 5 GW 108|0522660108|K.7|DEK 5 GW 199|0522660199|K.8|DEK 5 GW E KLEIN|0522861051|K.8|DEK 5/5 PLUS MC NEUTRAL|1854490000|K.11|
|DEK 5 GW 109|0522660109|K.7|DEK 5 GW 2|0522660002|K.7|DEK 5 GW ERDE|0576261202|K.8|DEK 5/5 PLUS MC SONDERDR.|1854500000|K.11|
|DEK 5 GW 11|0522660011|K.7|DEK 5 GW 20|0522660020|K.7|DEK 5 GW ERDE I.KR.|0576261203|K.8|DEK 5/6 MC BEDRUCKT|1609830000|K.11|
|DEK 5 GW 110|0522660110|K.7|DEK 5 GW 200|0522660200|K.8|DEK 5 GW F|0522761026|K.8|DEK 5/6 MC NEUTRAL|1609820000|K.11|
|DEK 5 GW 111|0522660111|K.7|DEK 5 GW 21|0522660021|K.7|DEK 5 GW F KLEIN|0522861052|K.8|DEK 5/6 PLUS MC NE WS|1011320000|K.11|
|DEK 5 GW 112|0522660112|K.7|DEK 5 GW 22|0522660022|K.7|DEK 5 GW G|0522761027|K.8|DEK 5/6,5 MC BEDRUCKT|1609850000|K.11|
|DEK 5 GW 113|0522660113|K.7|DEK 5 GW 23|0522660023|K.7|DEK 5 GW G KLEIN|0522861053|K.8|DEK 5/6,5 MC NEUTRAL|1609840000|K.11|
|DEK 5 GW 114|0522660114|K.7|DEK 5 GW 24|0522660024|K.7|DEK 5 GW H|0522761028|K.8|DEK 5/7.5 MC NEUTRAL|1720620000|K.11|
|DEK 5 GW 115|0522660115|K.7|DEK 5 GW 25|0522660025|K.7|DEK 5 GW H KLEIN|0522861054|K.8|DEK 5/7.5 MC SONDERDR.|1770490000|K.11|
|DEK 5 GW 116|0522660116|K.7|DEK 5 GW 26|0522660026|K.7|DEK 5 GW I|0522761029|K.8|DEK 5/8 MC Neutral|1856740000|K.11|
|DEK 5 GW 117|0522660117|K.7|DEK 5 GW 27|0522660027|K.7|DEK 5 GW I KLEIN|0522861055|K.8|DEK 5/8 MC Sonderdruck|1856750000|K.11|
|DEK 5 GW 118|0522660118|K.7|DEK 5 GW 28|0522660028|K.7|DEK 5 GW J|0522761030|K.8|DEK 6 BL NEUTRAL|0468591693|K.8|
|DEK 5 GW 119|0522660119|K.7|DEK 5 GW 29|0522660029|K.7|DEK 5 GW J KLEIN|0522861056|K.8|DEK 6 BR NEUTRAL|0468591692|K.8|
|DEK 5 GW 12|0522660012|K.7|DEK 5 GW 3|0522660003|K.7|DEK 5 GW K|0522761031|K.8|DEK 6 FS 101-150|0468760101|K.8|
|DEK 5 GW 120|0522660120|K.7|DEK 5 GW 30|0522660030|K.7|DEK 5 GW K KLEIN|0522861057|K.8|DEK 6 FS 1-50|0468760001|K.8|
|DEK 5 GW 121|0522660121|K.7|DEK 5 GW 31|0522660031|K.7|DEK 5 GW L|0522761032|K.8|DEK 6 FS 151-200|0468760151|K.8|
|DEK 5 GW 122|0522660122|K.7|DEK 5 GW 32|0522660032|K.7|DEK 5 GW L KLEIN|0522861058|K.8|DEK 6 FS 201-250|0468760201|K.8|
|DEK 5 GW 123|0522660123|K.7|DEK 5 GW 33|0522660033|K.7|DEK 5 GW L1|0522361075|K.8|DEK 6 FS 251-300|0468760251|K.8|
|DEK 5 GW 124|0522660124|K.7|DEK 5 GW 34|0522660034|K.7|DEK 5 GW L2|0522361076|K.8|DEK 6 FS 301-350|0468760301|K.8|
|DEK 5 GW 125|0522660125|K.7|DEK 5 GW 35|0522660035|K.7|DEK 5 GW L3|0522361077|K.8|DEK 6 FS 351-400|0468760351|K.8|
|DEK 5 GW 126|0522660126|K.7|DEK 5 GW 36|0522660036|K.7|DEK 5 GW M|0522761033|K.8|DEK 6 FS 401-450|0468760401|K.8|
|DEK 5 GW 127|0522660127|K.7|DEK 5 GW 37|0522660037|K.7|DEK 5 GW M KLEIN|0522861059|K.8|DEK 6 FS 451-500|0468760451|K.8|
|DEK 5 GW 128|0522660128|K.7|DEK 5 GW 38|0522660038|K.7|DEK 5 GW Mp|0537261235|K.8|DEK 6 FS 501-550|0468760501|K.8|
|DEK 5 GW 129|0522660129|K.7|DEK 5 GW 39|0522660039|K.7|DEK 5 GW N|0522761034|K.8|DEK 6 FS 51-100|0468760051|K.8|
|DEK 5 GW 13|0522660013|K.7|DEK 5 GW 4|0522660004|K.7|DEK 5 GW N KLEIN|0522861060|K.8|DEK 6 FS 551-600|0468760551|K.8|
|DEK 5 GW 130|0522660130|K.7|DEK 5 GW 40|0522660040|K.7|DEK 5 GW O|0522761035|K.8|DEK 6 FS 601-650|0468760601|K.8|
|DEK 5 GW 131|0522660131|K.7|DEK 5 GW 41|0522660041|K.7|DEK 5 GW O KLEIN|0522861061|K.8|DEK 6 FS 651-700|0468760651|K.8|
|DEK 5 GW 132|0522660132|K.7|DEK 5 GW 42|0522660042|K.7|DEK 5 GW P|0522761036|K.8|DEK 6 FS 701-750|0468760701|K.8|
|DEK 5 GW 133|0522660133|K.7|DEK 5 GW 43|0522660043|K.7|DEK 5 GW P KLEIN|0522861062|K.8|DEK 6 FS 751-800|0468760751|K.8|
|DEK 5 GW 134|0522660134|K.7|DEK 5 GW 44|0522660044|K.7|DEK 5 GW PE|0537261187|K.8|DEK 6 FS 801-850|0468760801|K.8|
|DEK 5 GW 135|0522660135|K.7|DEK 5 GW 45|0522660045|K.7|DEK 5 GW PEN|0537261188|K.8|DEK 6 FS 851-900|0468760851|K.8|
|DEK 5 GW 136|0522660136|K.7|DEK 5 GW 46|0522660046|K.7|DEK 5 GW Q|0522761037|K.8|DEK 6 FS 901-950|0468760901|K.8|
|DEK 5 GW 137|0522660137|K.7|DEK 5 GW 47|0522660047|K.7|DEK 5 GW Q KLEIN|0522861063|K.8|DEK 6 FS 951-999|0468760951|K.8|
|DEK 5 GW 138|0522660138|K.7|DEK 5 GW 48|0522660048|K.7|DEK 5 GW R|0522761038|K.8|DEK 6 FSZ 1-10|0133360001|K.8|
|DEK 5 GW 139|0522660139|K.7|DEK 5 GW 49|0522660049|K.7|DEK 5 GW R KLEIN|0522861064|K.8|DEK 6 FSZ 11-20|0133360011|K.8|
|DEK 5 GW 14|0522660014|K.7|DEK 5 GW 5|0522660005|K.7|DEK 5 GW RT/SW +|0576291737|K.8|DEK 6 FSZ 21-30|0133360021|K.8|
|DEK 5 GW 140|0522660140|K.7|DEK 5 GW 50|0522660050|K.7|DEK 5 GW S|0522761039|K.8|DEK 6 FSZ 31-40|0133360031|K.8|
|DEK 5 GW 141|0522660141|K.7|DEK 5 GW 51|0522660051|K.7|DEK 5 GW S KLEIN|0522861065|K.8|DEK 6 FSZ 41-50|0133360041|K.8|
|DEK 5 GW 142|0522660142|K.7|DEK 5 GW 52|0522660052|K.7|DEK 5 GW T|0522761040|K.8|DEK 6 FSZ 51-60|0133360051|K.8|
|DEK 5 GW 143|0522660143|K.7|DEK 5 GW 53|0522660053|K.7|DEK 5 GW T KLEIN|0522861066|K.8|DEK 6 FSZ 61-70|0133360061|K.8|
|DEK 5 GW 144|0522660144|K.7|DEK 5 GW 54|0522660054|K.7|DEK 5 GW U|0522761041|K.8|DEK 6 FSZ 71-80|0133360071|K.8|
|DEK 5 GW 145|0522660145|K.7|DEK 5 GW 55|0522660055|K.7|DEK 5 GW U KLEIN|0522861067|K.8|DEK 6 FSZ 81-90|0133360081|K.8|
|DEK 5 GW 146|0522660146|K.7|DEK 5 GW 56|0522660056|K.7|DEK 5 GW V|0522761042|K.8|DEK 6 FSZ 91-100|0133360091|K.8|
|DEK 5 GW 147|0522660147|K.7|DEK 5 GW 57|0522660057|K.7|DEK 5 GW V KLEIN|0522861068|K.8|DEK 6 FW 1,3,5...99|1358660000|K.8|
|DEK 5 GW 148|0522660148|K.7|DEK 5 GW 58|0522660058|K.7|DEK 5 GW W|0522761043|K.8|DEK 6 FW 101-150|0468660101|K.8|
|DEK 5 GW 149|0522660149|K.7|DEK 5 GW 59|0522660059|K.7|DEK 5 GW W KLEIN|0522861069|K.8|DEK 6 FW 1-5 (10X)|0688660000|K.8|
|DEK 5 GW 15|0522660015|K.7|DEK 5 GW 6|0522660006|K.7|DEK 5 GW W-STROM|0576261215|K.8|DEK 6 FW 1-50|0468660001|K.8|
|DEK 5 GW 150|0522660150|K.7|DEK 5 GW 60|0522660060|K.7|DEK 5 GW X|0522761044|K.8|DEK 6 FW 151-200|0468660151|K.8|
|DEK 5 GW 151|0522660151|K.7|DEK 5 GW 61|0522660061|K.7|DEK 5 GW X KLEIN|0522861070|K.8|DEK 6 FW 2,4,...100|1358760000|K.8|
|DEK 5 GW 152|0522660152|K.7|DEK 5 GW 62|0522660062|K.7|DEK 5 GW Y|0522761045|K.8|DEK 6 FW 201-250|0468660201|K.8|
|DEK 5 GW 153|0522660153|K.7|DEK 5 GW 63|0522660063|K.7|DEK 5 GW Y KLEIN|0522861071|K.8|DEK 6 FW 251-300|0468660251|K.8|
|DEK 5 GW 154|0522660154|K.7|DEK 5 GW 64|0522660064|K.7|DEK 5 GW Z|0522761046|K.8|DEK 6 FW 301-350|0468660301|K.8|
|DEK 5 GW 155|0522660155|K.7|DEK 5 GW 65|0522660065|K.7|DEK 5 GW Z KLEIN|0522861072|K.8|DEK 6 FW 351-400|0468660351|K.8|
|DEK 5 GW 156|0522660156|K.7|DEK 5 GW 66|0522660066|K.7|DEK 5 NEUTRAL|0473360000|K.8|DEK 6 FW 401-450|0468660401|K.8|
|DEK 5 GW 157|0522660157|K.7|DEK 5 GW 67|0522660067|K.7|DEK 5 OR NEUTRAL|0473391690|K.8|DEK 6 FW 451-500|0468660451|K.8|
|DEK 5 GW 158|0522660158|K.7|DEK 5 GW 68|0522660068|K.7|DEK 5 RT NEUTRAL|0473391686|K.8|DEK 6 FW 501-550|0468660501|K.8|
|DEK 5 GW 159|0522660159|K.7|DEK 5 GW 69|0522660069|K.7|DEK 5 SW NEUTRAL|0473391694|K.8|DEK 6 FW 51-100|0468660051|K.8|
|DEK 5 GW 16|0522660016|K.7|DEK 5 GW 7|0522660007|K.7|DEK 5 VI NEUTRAL|0473391689|K.8|DEK 6 FW 551-600|0468660551|K.8|
|DEK 5 GW 160|0522660160|K.8|DEK 5 GW 70|0522660070|K.7|DEK 5/3,5 MC bedruckt|1767730000|K.11|DEK 6 FW 601-650|0468660601|K.8|
|DEK 5 GW 161|0522660161|K.8|DEK 5 GW 71|0522660071|K.7|DEK 5/3,5 MC FSZ 101-110|1762320101|K.8|DEK 6 FW 651-700|0468660651|K.8|
|DEK 5 GW 162|0522660162|K.8|DEK 5 GW 72|0522660072|K.7|DEK 5/3,5 MC FSZ 1-10|1762320001|K.8|DEK 6 FW 701-750|0468660701|K.8|
|DEK 5 GW 163|0522660163|K.8|DEK 5 GW 73|0522660073|K.7|DEK 5/3,5 MC FSZ 111-120|1762320111|K.8|DEK 6 FW 751-800|0468660751|K.8|
|DEK 5 GW 164|0522660164|K.8|DEK 5 GW 74|0522660074|K.7|DEK 5/3,5 MC FSZ 11-20|1762320011|K.8|DEK 6 FW 801-850|0468660801|K.8|
|DEK 5 GW 165|0522660165|K.8|DEK 5 GW 75|0522660075|K.7|DEK 5/3,5 MC FSZ 121-130|1762320121|K.8|DEK 6 FW 851-900|0468660851|K.8|
|DEK 5 GW 166|0522660166|K.8|DEK 5 GW 76|0522660076|K.7|DEK 5/3,5 MC FSZ 131-140|1762320131|K.8|DEK 6 FW 901-950|0468660901|K.8|
|DEK 5 GW 167|0522660167|K.8|DEK 5 GW 77|0522660077|K.7|DEK 5/3,5 MC FSZ 141-150|1762320141|K.8|DEK 6 FW 951-999|0468660951|K.8|
|DEK 5 GW 168|0522660168|K.8|DEK 5 GW 78|0522660078|K.7|DEK 5/3,5 MC FSZ 21-30|1762320021|K.8|DEK 6 FW L,N,PE|0632560000|K.8|
|DEK 5 GW 169|0522660169|K.8|DEK 5 GW 79|0522660079|K.7|DEK 5/3,5 MC FSZ 31-40|1762320031|K.8|DEK 6 FWZ 101-110|0518960101|K.8|
|DEK 5 GW 17|0522660017|K.7|DEK 5 GW 8|0522660008|K.7|DEK 5/3,5 MC FSZ 41-50|1762320041|K.8|DEK 6 FWZ 1-10|0518960001|K.8|
|DEK 5 GW 170|0522660170|K.8|DEK 5 GW 80|0522660080|K.7|DEK 5/3,5 MC FSZ 51-60|1762320051|K.8|DEK 6 FWZ 111-120|0518960111|K.8|
|DEK 5 GW 171|0522660171|K.8|DEK 5 GW 81|0522660081|K.7|DEK 5/3,5 MC FSZ 61-70|1762320061|K.8|DEK 6 FWZ 11-20|0518960011|K.8|
|DEK 5 GW 172|0522660172|K.8|DEK 5 GW 82|0522660082|K.7|DEK 5/3,5 MC FSZ 71-80|1762320071|K.8|DEK 6 FWZ 121-130|0518960121|K.8|
|DEK 5 GW 173|0522660173|K.8|DEK 5 GW 83|0522660083|K.7|DEK 5/3,5 MC FSZ 81-90|1762320081|K.8|DEK 6 FWZ 131-140|0518960131|K.8|
|DEK 5 GW 174|0522660174|K.8|DEK 5 GW 84|0522660084|K.7|DEK 5/3,5 MC FSZ 91-100|1762320091|K.8|DEK 6 FWZ 141-150|0518960141|K.8|
|DEK 5 GW 175|0522660175|K.8|DEK 5 GW 85|0522660085|K.7|DEK 5/3,5 MC GW 0|1755281000|K.8|DEK 6 FWZ 151-160|0518960151|K.8|
**X.4**
|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|DEK 6 FWZ 161-170|0518960161|K.8|DEK 6 GW 79|0526960079|K.9|DEK 6,5 NEUTRAL|0468060000|K.9|DKT 4/35|0687460000|A.19|
|DEK 6 FWZ 171-180|0518960171|K.8|DEK 6 GW 8|0526960008|K.8|DEK 6,5 OR NEUTRAL|0468091690|K.9|DKT 4/35 PT100|8014720000|A.56|
|DEK 6 FWZ 181-190|0518960181|K.8|DEK 6 GW 80|0526960080|K.9|DEK 6,5 RT NEUTRAL|0468091686|K.9|DKT 4V 2STB|1304860000|B.17|
|DEK 6 FWZ 191-200|0518960191|K.8|DEK 6 GW 81|0526960081|K.9|DEK 6,5 SW NEUTRAL|0468091694|K.9|DKT 4V/35 2STB|1304960000|A.19|
|DEK 6 FWZ 201-210|0518960201|K.8|DEK 6 GW 82|0526960082|K.9|DEK 6,5 VI NEUTRAL|0468091689|K.9|DMS 2 Set|0664600000|J.11|
|DEK 6 FWZ 21-30|0518960021|K.8|DEK 6 GW 83|0526960083|K.9|DEK 8 BEDR./FARBIG|1289690000|K.9|DMS 3|9007440000|J.10|
|DEK 6 FWZ 31-40|0518960031|K.8|DEK 6 GW 84|0526960084|K.9|DEK 8 FS 1-50 TAMPOPR.|1653350001|K.9|DMS 3 SET 1|9007470000|J.10|
|DEK 6 FWZ 41-50|0518960041|K.8|DEK 6 GW 85|0526960085|K.9|DEK 8 FS 51-100 TAMPOP.|1653350051|K.9|DMS 3 SET 2|9007480000|J.10|
|DEK 6 FWZ 51-60<br>DEK 6 FWZ 61-70<br>DEK 6 FWZ 71-80<br>DEK 6 FWZ 81-90|0518960051<br>0518960061<br>0518960071<br>0518960081|K.8<br>K.8<br>K.8<br>K.8|DEK 6 GW 86<br>DEK 6 GW 87<br>DEK 6 GW 88<br>DEK 6 GW 89|0526960086<br>0526960087<br>0526960088<br>0526960089|K.9<br>K.9<br>K.9<br>K.9|DEK 8 FSZ 1-10<br>DEK 8 FSZ 11-20<br>DEK 8 FSZ 21-30<br>DEK 8 FSZ 31-40|1289660001<br>1289660011<br>1289660021<br>1289660031|K.9<br>K.9<br>K.9<br>K.9|DMS MANUELL 0,5-1,7<br>DMS MANUELL 2,0-8,0<br>DMSI MANUELL 0,5-1,7<br>DMSI MANUELL 2,0-8,0|9918370000<br>9918380000<br>9918390000<br>9918400000|J.18<br>J.18<br>J.19<br>J.19|
|DEK 6 FWZ 91-100|0518960091|K.8|DEK 6 GW 9|0526960009|K.8|DEK 8 FSZ 41-50|1289660041|K.9|DQS 2 1D PS2,3 AG|0471460000|I.13|
|DEK 6 FWZ L1-ERDE I.KRE|0631961203|K.8|DEK 6 GW 90|0526960090|K.9|DEK 8 FSZ 51-60|1289660051|K.9|DQS 2 PS2,3 AG M.BRUECK|0471560000|<br>I.13|
|DEK 6 FWZ L1-PE|0631961187|K.8|DEK 6 GW 91|0526960091|K.9|DEK 8 FSZ 61-70|1289660061|K.9|DQS 2 PS2.3 O.BATE|0471660000|I.13|
|DEK 6 FWZ R,S,T,N,ERDE|0631860000|K.8|DEK 6 GW 92|0526960092|K.9|DEK 8 FSZ 71-80|1289660071|K.9|DS 12.5 SAK10|0207630000|<br>I.12|
|DEK 6 GE NEUTRAL|0468591687|K.8|DEK 6 GW 93|0526960093|K.9|DEK 8 FSZ 81-90|1289660081|K.9|DS 12.5 SAK6N|0207730000|<br>I.12|
|DEK 6 GN NEUTRAL|0468591688|K.8|DEK 6 GW 94|0526960094|K.9|DEK 8 FSZ 91-100|1289660091|K.9|DS 14 SAK4|0207530000|<br>I.12|
|DEK 6 GR NEUTRAL|0468591691|K.8|DEK 6 GW 95|0526960095|K.9|DEK 8 FW 1-50 TAMPOPR.|1653340001|K.9|DS 9 SAK2.5|0330930000|<br>I.12|
|DEK 6 GW -|1318061199|K.9|DEK 6 GW 96|0526960096|K.9|DEK 8 FW 51-100 TAMPOP.|1653340051|K.9|DSTV VH 6.5|0286400000|I.10|
|DEK 6 GW +|1318061198|K.9|DEK 6 GW 97|0526960097|K.9|DEK 8 FWZ 101-110|1276960101|K.9||||
|DEK 6 GW 0<br>DEK 6 GW 1|0526961000<br>0526960001|K.8<br>K.8|DEK 6 GW 98<br>DEK 6 GW 99|0526960098<br>0526960099|K.9<br>K.9|DEK 8 FWZ 1-10<br>DEK 8 FWZ 111-120|1276960001<br>1276960111|K.9<br>K.9|**E**|||
|DEK 6 GW 10|0526960010|K.8|DEK 6 GW BL/SW -|1318091741|K.9|DEK 8 FWZ 11-20|1276960011|K.9|E 14/10A RT|0328400000|B.24|
|DEK 6 GW 100|0526960100|K.9|DEK 6 GW ERDE|1318061202|K.9|DEK 8 FWZ 121-130|1276960121|K.9|E 14/10A RT|0328400000|A.26|
|DEK 6 GW 11|0526960011|K.8|DEK 6 GW ERDE I.KR.|1318061203|K.9|DEK 8 FWZ 131-140|1276960131|K.9|E 14/10A RT|0328400000|B.26|
|DEK 6 GW 12|0526960012|K.8|DEK 6 GW PE|1318061187|K.9|DEK 8 FWZ 141-150|1276960141|K.9|E 14/10A RT|0328400000|A.28|
|DEK 6 GW 13|0526960013|K.8|DEK 6 GW RT/SW +|1318091737|K.9|DEK 8 FWZ 21-30|1276960021|K.9|E 14/16A GR|0328500000|B.24|
|DEK 6 GW 14|0526960014|K.8|DEK 6 NEUTRAL|0468560000|K.8|DEK 8 FWZ 31-40|1276960031|K.9|E 14/16A GR|0328500000|B.26|
|DEK 6 GW 15|0526960015|K.8|DEK 6 NEUTRAL|0468560000|K.9|DEK 8 FWZ 41-50|1276960041|K.9|E 14/16A GR|0328500000|A.28|
|DEK 6 GW 16|0526960016|K.8|DEK 6 OR NEUTRAL|0468591690|K.9|DEK 8 FWZ 51-60|1276960051|K.9|E 14/16A GR|0328500000|A.26|
|DEK 6 GW 17|0526960017|K.8|DEK 6 RT NEUTRAL|0468591686|K.9|DEK 8 FWZ 61-70|1276960061|K.9|E 14/2A RS|0137400000|A.28|
|DEK 6 GW 18|0526960018|K.8|DEK 6 SW NEUTRAL|0468591694|K.9|DEK 8 FWZ 71-80|1276960071|K.9|E 14/2A RS|0137400000|A.26|
|DEK 6 GW 19|0526960019|K.8|DEK 6 VI NEUTRAL|0468591689|K.9|DEK 8 FWZ 81-90|1276960081|K.9|E 14/2A RS|0137400000|B.26|
|DEK 6 GW 2|0526960002|K.8|DEK 6,5 BL NEUTRAL|0468091693|K.9|DEK 8 FWZ 91-100|1276960091|K.9|E 14/2A RS|0137400000|B.24|
|DEK 6 GW 20|0526960020|K.8|DEK 6,5 FS 101-150|0468260101|K.9|DEK 8 GE NEUTRAL|1277091687|K.9|E 14/4A BR|0137500000|A.26|
|DEK 6 GW 200|0526960200|K.9|DEK 6,5 FS 1-50|0468260001|K.9|DEK 8 GN NEUTRAL|1277091688|K.9|E 14/4A BR|0137500000|B.24|
|DEK 6 GW 21|0526960021|K.8|DEK 6,5 FS 151-200|0468260151|K.9|DEK 8 NEUTRAL|1277060000|K.9|E 14/4A BR|0137500000|B.26|
|DEK 6 GW 22|0526960022|K.8|DEK 6,5 FS 201-250|0468260201|K.9|DEK 8 OR NEUTRAL|1277091690|K.9|E 14/4A BR|0137500000|A.28|
|DEK 6 GW 23|0526960023|K.8|DEK 6,5 FS 251-300|0468260251|K.9|DEK 8 RT NEUTRAL|1277091686|K.9|E 14/6A GN|0328300000|A.26|
|DEK 6 GW 24|0526960024|K.8|DEK 6,5 FS 301-350|0468260301|K.9|DEK 8 SONDERDR.FARBIG|1326690000|K.9|E 14/6A GN|0328300000|B.24|
|DEK 6 GW 25|0526960025|K.8|DEK 6,5 FS 351-400|0468260351|K.9|DEK 8 SONDERDR.WEISS|1326660000|K.9|E 14/6A GN|0328300000|A.28|
|DEK 6 GW 26|0526960026|K.8|DEK 6,5 FS 401-450|0468260401|K.9|DEK 8 VI NEUTRAL|1277091689|K.9|E 14/6A GN|0328300000|B.26|
|DEK 6 GW 27|0526960027|K.8|DEK 6,5 FS 451-500|0468260451|K.9|DK 4|0355460000|B.10|E 16/10A RT TNDZ|0208500000|A.26|
|DEK 6 GW 28|0526960028|K.8|DEK 6,5 FS 501-550|0468260501|K.9|DK 4 BL|0355480000|B.10|E 16/10A RT TNDZ|0208500000|B.24|
|DEK 6 GW 29|0526960029|K.8|DEK 6,5 FS 51-100|0468260051|K.9|DK 4 Q/EN|1907040000|C.4|E 16/10A RT TNDZ|0208500000|A.28|
|DEK 6 GW 3|0526960003|K.8|DEK 6,5 FS 551-600|0468260551|K.9|DK 4 Q/EN BL|1907030000|C.4|E 16/10A RT TNDZ|0208500000|B.26|
|DEK 6 GW 30|0526960030|K.8|DEK 6,5 FS 601-650|0468260601|K.9|DK 4 QV/EN|1907020000|C.5|E 16/16A GR TNDZ|0208600000|A.28|
|DEK 6 GW 31|0526960031|K.8|DEK 6,5 FS 651-700|0468260651|K.9|DK 4 SW 1X1|0536560000|B.38|E 16/16A GR TNDZ|0208600000|A.26|
|DEK 6 GW 32|0526960032|K.8|DEK 6,5 FS 701-750|0468260701|K.9|DK 4/32 1D 1K5|0685260000|B.60|E 16/16A GR TNDZ|0208600000|B.26|
|DEK 6 GW 33|0526960033|K.8|DEK 6,5 FS 751-800|0468260751|K.9|DK 4/32 1D CSA A1|0484060000|B.58|E 16/16A GR TNDZ|0208600000|B.24|
|DEK 6 GW 34|0526960034|K.8|DEK 6,5 FS 801-850|0468260801|K.9|DK 4/32 1D CSA A2|0467960000|B.59|E 16/20A BL TNDZ|0208700000|B.24|
|DEK 6 GW 35|0526960035|K.8|DEK 6,5 FS 851-900|0468260851|K.9|DK 4/32 1D CSA GET.SCH.|0544660000|B.58|E 16/20A BL TNDZ|0208700000|A.28|
|DEK 6 GW 36|0526960036|K.8|DEK 6,5 FS 901-950|0468260901|K.9|DK 4/32 2D A1|0663960000|B.60|E 16/20A BL TNDZ|0208700000|A.26|
|DEK 6 GW 37|0526960037|K.8|DEK 6,5 FS 951-999|0468260951|K.9|DK 4/32 2D CSA A2|0523760000|B.59|E 16/20A BL TNDZ|0208700000|B.26|
|DEK 6 GW 38|0526960038|K.8|DEK 6,5 FSZ 1-10|0407360001|K.9|DK 4/32 2D CSA GET.SCH.|0642760000|B.59|E 16/25A GE TNDZ|0208800000|B.24|
|DEK 6 GW 39|0526960039|K.8|DEK 6,5 FSZ 11-20|0407360011|K.9|DK 4/32 GL 100K 115VAC|0569560000|B.57|E 16/25A GE TNDZ|0208800000|A.26|
|DEK 6 GW 4|0526960004|K.8|DEK 6,5 FSZ 21-30|0407360021|K.9|DK 4/32 LD GR 24VDC A2|0646560000|B.56|E 16/25A GE TNDZ|0208800000|B.26|
|DEK 6 GW 40|0526960040|K.8|DEK 6,5 FSZ 31-40|0407360031|K.9|DK 4/32 LD ROT 24VDC|0210160000|B.57|E 16/25A GE TNDZ|0208800000|A.28|
|DEK 6 GW 41|0526960041|K.8|DEK 6,5 FSZ 41-50|0407360041|K.9|DK 4/32 LD ROT 24VDC A1|0495360000|B.56|E 18/20A BL|0361300000|A.28|
|DEK 6 GW 42|0526960042|K.8|DEK 6,5 FSZ 51-60|0407360051|K.9|DK 4/32 LD ROT 24VDC A2|0474460000|B.56|E 18/20A BL|0361300000|B.25|
|DEK 6 GW 43|0526960043|K.8|DEK 6,5 FSZ 61-70|0407360061|K.9|DK 4/32 RC 220R/220NF|0692160000|B.61|E 18/20A BL|0361300000|A.27|
|DEK 6 GW 44|0526960044|K.8|DEK 6,5 FSZ 71-80|0407360071|K.9|DK 4/35|0527660000|A.12|E 18/20A BL|0361300000|B.26|
|DEK 6 GW 45|0526960045|K.8|DEK 6,5 FSZ 81-90|0407360081|K.9|DK 4/35 1D 1K5 GET.SCH|0396960000|A.55|E 18/25A GE|0361400000|B.26|
|DEK 6 GW 46|0526960046|K.8|DEK 6,5 FSZ 91-100|0407360091|K.9|DK 4/35 1D A1|0538960000|A.53|E 18/25A GE|0361400000|B.25|
|DEK 6 GW 47|0526960047|K.8|DEK 6,5 FW 101-150|0468160101|K.9|DK 4/35 1D A1 BL|0538980000|A.53|E 18/25A GE|0361400000|A.28|
|DEK 6 GW 48|0526960048|K.8|DEK 6,5 FW 1-50|0468160001|K.9|DK 4/35 1D A2|0538860000|A.54|E 18/25A GE|0361400000|A.27|
|DEK 6 GW 49|0526960049|K.8|DEK 6,5 FW 151-200|0468160151|K.9|DK 4/35 1D GET.SCH.|0396360000|A.53|E 18/35A SW|0361500000|B.26|
|DEK 6 GW 5|0526960005|K.8|DEK 6,5 FW 201-250|0468160201|K.9|DK 4/35 2D GET.SCH. A1|0396660000|A.54|E 18/35A SW|0361500000|A.28|
|DEK 6 GW 50|0526960050|K.8|DEK 6,5 FW 251-300|0468160251|K.9|DK 4/35 2D GET.SCH. A1|0396760000|A.55|E 18/50A WS|0361600000|B.25|
|DEK 6 GW 51|0526960051|K.8|DEK 6,5 FW 301-350|0468160301|K.9|DK 4/35 2D GET.SCH. A2|0396860000|A.55|E 18/50A WS|0361600000|A.27|
|DEK 6 GW 52|0526960052|K.8|DEK 6,5 FW 351-400|0468160351|K.9|DK 4/35 BL|0527680000|A.12|E 18/50A WS|0361600000|A.28|
|DEK 6 GW 53|0526960053|K.8|DEK 6,5 FW 401-450|0468160401|K.9|DK 4/35 GL 1D I1,0A|1111160000|A.52|E 18/50A WS|0361600000|B.26|
|DEK 6 GW 54|0526960054|K.8|DEK 6,5 FW 451-500|0468160451|K.9|DK 4/35 LD 1D ROT 24VAC|0395960000|A.51|E 18/63A KU|0361700000|B.26|
|DEK 6 GW 55|0526960055|K.8|DEK 6,5 FW 501-550|0468160501|K.9|DK 4/35 LD GR 24VDC|0210060000|A.51|E 18/63A KU|0361700000|A.27|
|DEK 6 GW 56|0526960056|K.8|DEK 6,5 FW 51-100|0468160051|K.9|DK 4/35 LD GR 24VDC|0210460000|A.51|E 18/63A KU|0361700000|B.25|
|DEK 6 GW 57|0526960057|K.8|DEK 6,5 FW 551-600|0468160551|K.9|DK 4/35 LD GR 24VDC|0395460000|A.50|E 18/63A KU|0361700000|A.28|
|DEK 6 GW 58|0526960058|K.8|DEK 6,5 FW 601-650|0468160601|K.9|DK 4/35 LD GR 24VDC|0395760000|A.50|EK 10|0354660000|B.13|
|DEK 6 GW 59|0526960059|K.8|DEK 6,5 FW 651-700|0468160651|K.9|DK 4/35 LD ROT 24VDC|0210260000|A.51|EK 10/35|0661360000|A.15|
|DEK 6 GW 6|0526960006|K.8|DEK 6,5 FW 701-750|0468160701|K.9|DK 4/35 RC 220R/220N|0053160000|A.56|EK 16|0374660000|B.13|
|DEK 6 GW 60|0526960060|K.8|DEK 6,5 FW 751-800|0468160751|K.9|DK 4Q/32|0590060000|B.10|EK 16/35|0190160000|A.15|
|DEK 6 GW 61|0526960061|K.8|DEK 6,5 FW 801-850|0468160801|K.9|DK 4Q/32 BL|0590080000|B.10|EK 2|0323100000|B.14|
|DEK 6 GW 62|0526960062|K.8|DEK 6,5 FW 851-900|0468160851|K.9|DK 4Q/35|0590160000|A.12|EK 2.5/35|0661060000|A.14|
|DEK 6 GW 63|0526960063|K.8|DEK 6,5 FW 901-950|0468160901|K.9|DK 4Q/35 BL|0590180000|A.12|EK 2.5N|0474360000|B.12|
|DEK 6 GW 64|0526960064|K.8|DEK 6,5 FW 951-999|0468160951|K.9|DK 4Q/35/TC TYP J|1284060000|A.34|EK 35|0354760000|B.13|
|DEK 6 GW 65|0526960065|K.8|DEK 6,5 FW L1-ERDE I.KR|0632161203|K.9|DK 4Q/35/TC TYP K|1284160000|A.34|EK 35/35|0661460000|A.16|
|DEK 6 GW 66|0526960066|K.9|DEK 6,5 FW L1-PE|0632161187|K.9|DK 4Q/35/TC TYP T|1285660000|A.34|EK 4|0354560000|B.12|
|DEK 6 GW 67|0526960067|K.9|DEK 6,5 FWZ 1-10|0519060001|K.9|DK 4Q/TC TYP J|1338060000|B.34|EK 4/35|0661160000|A.14|
|DEK 6 GW 68|0526960068|K.9|DEK 6,5 FWZ 11-20|0519060011|K.9|DK 4Q/TC TYP K|1338260000|B.34|EK 6/35|0661260000|A.15|
|DEK 6 GW 69|0526960069|K.9|DEK 6,5 FWZ 21-30|0519060021|K.9|DK 4Q/TC TYP T|1338160000|B.34|EK 70/35/M.2ZB O.IK|1338300000|A.17|
|DEK 6 GW 7|0526960007|K.8|DEK 6,5 FWZ 31-40|0519060031|K.9|DK 4QV/32|0590260000|B.11|EK 95/35/1ZB BK|0535300000|A.16|
|DEK 6 GW 70|0526960070|K.9|DEK 6,5 FWZ 41-50|0519060041|K.9|DK 4QV/32 BL|0590280000|B.11|ELSB 10 BEZ. 1-10|0143500000|F.4|
|DEK 6 GW 71|0526960071|K.9|DEK 6,5 FWZ 51-60|0519060051|K.9|DK 4QV/35|0363660000|A.13|ELSB 2 BEZ. 1-2|0143200000|F.4|
|DEK 6 GW 72|0526960072|K.9|DEK 6,5 FWZ 61-70|0519060061|K.9|DK 4QV/35 BL|0363680000|A.13|ELSB 4 BEZ. 1-4|0143300000|F.4|
|DEK 6 GW 73|0526960073|K.9|DEK 6,5 FWZ 71-80|0519060071|K.9|DK 4S SF 6.3/2.8|0631260000|B.37|ELSB 6 BEZ. 1-6|0143400000|F.4|
|DEK 6 GW 74|0526960074|K.9|DEK 6,5 FWZ 81-90|0519060081|K.9|DK 4S/35 SF 6.3/2.8|0686660000|A.39|ELSO 10 F.KS 10|0143100000|F.4|
|DEK 6 GW 75|0526960075|K.9|DEK 6,5 FWZ 91-100|0519060091|K.9|DK 4SS/35 FF 4X6.3/2.8|0217160000|A.38|ELSO 2 F.KS 2|0142800000|F.4|
|DEK 6 GW 76|0526960076|K.9|DEK 6,5 FWZ R,S,T,N,ERD|0632060000|K.9|DKSUE NSCH/ESCH|0280100000|H.3|ELSO 4 F.KS 4|0142900000|F.4|
|DEK 6 GW 77|0526960077|K.9|DEK 6,5 GE NEUTRAL|0468091687|K.9|DKT 4|0687360000|B.17|ELSO 6 F.KS 6|0143000000|F.4|
|DEK 6 GW 78|0526960078|K.9|DEK 6,5 GN NEUTRAL|0468091688|K.9|DKT 4/32 PT100|8014730000|B.61|EM 8/30|1806120000|K.19|
**X**
**X.5**
|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|EP 1 SAKG28/32 HP/DBR<br>EP 1 SAKG28/32 HP/DBR|0205100000<br>0205100000|B.50<br>B.47|**G**|||GZ 12,5A/FF<br>GZ 12,5A/FF|0245400000<br>0245400000|B.26<br>A.28|H0,75/17 ZH W<br>H0,75/17 ZH W SV|9037240000<br>9004900000|J.28<br>J.28|
|EP 1 SAKG28/32 HP/DBR|0205100000|I.4|G 20/0.10A/F|0430300000|B.26|GZ 2.0A|0294500000|B.26|H0,75/17D ZH GR|9037420000|J.29|
|EP 1 SAKG28/32 HP/DBR|0205100000|B.48|G 20/0.10A/F|0430300000|A.23|GZ 2.0A|0294500000|A.28|H0,75/17D ZH GR SV|9004770000|J.29|
|EP 1 SAKG28/32 HP/DBR|0205100000|B.49|G 20/0.10A/F|0430300000|A.22|GZ 2.0A|0294500000|A.23|H0,75/17T ZH HBL|9037620000|J.30|
|EP 1 SAKG28/32 HP/DBR|0205100000|B.46|G 20/0.10A/F|0430300000|B.20|GZ 3.0A|0295700000|A.28|H0,75/17T ZH HBL SV|9005140000|J.30|
|EP 1 SAKG28/32 HP/TF/GE|0205200000|B.46|G 20/0.10A/F|0430300000|B.21|GZ 3.0A|0295700000|B.26|H0,75/18 W|9025910000|J.22|
|EP 1 SAKG28/32 HP/TF/GE|0205200000|B.47|G 20/0.10A/F|0430300000|A.28|GZ 3.0A|0295700000|A.23|H0,75/18 W SV|9028300000|J.22|
|EP 1 SAKG28/32 HP/TF/GE<br>EP 1 SAKG28/32 HP/TF/GE<br>EP 1 SAKG28/32 HP/TF/GE<br>EP 1 SAKG28/32 HP/TF/GE|0205200000<br>0205200000<br>0205200000<br>0205200000|B.48<br>B.49<br>B.50<br>I.4|G 20/0.20A/F<br>G 20/0.20A/F<br>G 20/0.20A/F<br>G 20/0.20A/F|0430400000<br>0430400000<br>0430400000<br>0430400000|A.28<br>A.23<br>B.26<br>A.22|GZ 5.0A<br>GZ 5.0A<br>GZ 7.0A<br>GZ 7.0A|0294600000<br>0294600000<br>0295800000<br>0295800000|B.26<br>A.28<br>A.28<br>B.26|H0,75/18D GR<br>H0,75/18T HBL<br>H0,75/19DS ZH GR<br>H0,75/19S ZH W|9019060000<br>9021060000<br>9202830000<br>9202820000|J.24<br>J.26<br>J.29<br>J.28|
|EP 1 SAKG32/35 HP/DBR<br>EP 1 SAKG32/35 HP/DBR<br>EP 1 SAKG32/35 HP/DBR|0180500000<br>0180500000<br>0180500000|A.44<br>B.49<br>A.43|G 20/0.20A/F<br>G 20/0.20A/F<br>G 20/0.25A/F|0430400000<br>0430400000<br>0430500000|B.20<br>B.21<br>B.26|**H**|||H0,75/19TS ZH HBL<br>H0,75/24,5 ZH W<br>H0,75/24,5D ZH GR|9202840000<br>9037250000<br>9037430000|J.30<br>J.28<br>J.29|
|EP 1 SAKG32/35 HP/DBR|0180500000|I.4|G 20/0.25A/F|0430500000|B.21|H 0,5/16 S OR|9202900000|J.32|H0,75/24,5T ZH HBL|9037630000|J.30|
|EP 1 SAKG32/35 HP/TF/GE|0180600000|I.4|G 20/0.25A/F|0430500000|A.22|H 1,5/24 XS SW|9202870000|J.31|H0,75/6|0282700000|J.33|
|EP 1 SAKG32/35 HP/TF/GE|0180600000|A.44|G 20/0.25A/F|0430500000|A.28|H 2,5/24 XS BL|9202880000|J.31|H0.75/14 HBL|9021040000|J.26|
|EP 1 SAKG32/35 HP/TF/GE|0180600000|A.43|G 20/0.25A/F|0430500000|B.20|H0,14/10 GR SV|9005180000|J.22|H1,0/10|0282800000|J.33|
|EP 1 SAKG32/35 HP/TF/GE|0180600000|B.49|G 20/0.25A/F|0430500000|A.23|H0,14/10T BR SV|9028250000|J.26|H1,0/12 GE|0409700000|J.22|
|EP 1/BW SAKG28/32 HP/DB|0271800000|I.5|G 20/0.50A/F|0430600000|A.28|H0,14/12 GR SV|9028240000|J.22|H1,0/12 GE SV|9028310000|J.22|
|EP 1/BW SAKG32/35 HP/DB|1381600000|I.5|G 20/0.50A/F|0430600000|B.21|H0,25/10 HBL|9025740000|J.22|H1,0/12D R|9019070000|J.24|
|EP 2 SAKG46/32 HP/DBR|0205300000|B.52|G 20/0.50A/F|0430600000|B.20|H0,25/10 HBL SV|9026050000|J.22|H1,0/12D R|9019070000|J.26|
|EP 2 SAKG46/32 HP/DBR|0205300000|B.51|G 20/0.50A/F|0430600000|A.23|H0,25/10T GE|9021010000|J.26|H1,0/14 GE|0463000000|J.22|
|EP 2 SAKG46/32 HP/DBR|0205300000|B.49|G 20/0.50A/F|0430600000|B.26|H0,25/10T GE SV|9021210000|J.26|H1,0/14 GE BD|9004320000|J.23|
|EP 2 SAKG46/32 HP/DBR|0205300000|B.48|G 20/0.50A/F|0430600000|A.22|H0,25/12 HBL|9025760000|J.22|H1,0/14 GE BD GSP|9005830000|J.23|
|EP 2 SAKG46/32 HP/DBR|0205300000|B.53|G 20/0.63A/F|0439000000|B.26|H0,25/12 HBL SV|9025780000|J.22|H1,0/14 GE SV|9026080000|J.22|
|EP 2 SAKG46/32 HP/DBR|0205300000|I.4|G 20/0.63A/F|0439000000|A.22|H0,25/12T GE|9021020000|J.26|H1,0/14D R|9019080000|J.26|
|EP 2 SAKG46/32 HP/DBR|0205300000|B.50|G 20/0.63A/F|0439000000|B.20|H0,25/12T GE SV|9021220000|J.26|H1,0/14D R|9019080000|J.24|
|EP 2 SAKG46/32 HP/TF/GE|0205400000|B.50|G 20/0.63A/F|0439000000|A.28|H0,25/5|9018910000|J.33|H1,0/14D R BD|9004330000|J.26|
|EP 2 SAKG46/32 HP/TF/GE|0205400000|B.49|G 20/1.00A/F|0430700000|B.20|H0,34/10 TK|9025750000|J.22|H1,0/14D R BD|9004330000|J.24|
|EP 2 SAKG46/32 HP/TF/GE|0205400000|B.51|G 20/1.00A/F|0430700000|A.28|H0,34/10 TK SV|9026030000|J.22|H1,0/14D R BD GSP|9005880000|J.27|
|EP 2 SAKG46/32 HP/TF/GE|0205400000|B.52|G 20/1.00A/F|0430700000|A.22|H0,34/12 TK|9025770000|J.22|H1,0/14D R BD GSP|9005880000|J.25|
|EP 2 SAKG46/32 HP/TF/GE|0205400000|B.48|G 20/1.00A/F|0430700000|B.26|H0,34/12 TK BD GSP|9004390000|J.23|H1,0/14D R SV|9019420000|J.26|
|EP 2 SAKG46/32 HP/TF/GE|0205400000|B.53|G 20/1.00A/F|0430700000|A.23|H0,34/12 TK SV|9025790000|J.22|H1,0/14D R SV|9019420000|J.24|
|EP 2 SAKG46/32 HP/TF/GE|0205400000|I.4|G 20/1.00A/F|0430700000|B.21|H0,5/10|9004050000|J.33|H1,0/14S GE|9025970000|J.32|
|EP 2 SAKG46/35 HP/DBR|0180700000|A.47|G 20/1.60A/F|0430800000|B.21|H0,5/10 OR SV|9028260000|J.22|H1,0/14S GE SV|9025710000|J.32|
|EP 2 SAKG46/35 HP/DBR|0180700000|A.46|G 20/1.60A/F|0430800000|B.20|H0,5/12 OR|0409500000|J.22|H1,0/14S R|9018560000|J.32|
|EP 2 SAKG46/35 HP/DBR|0180700000|A.45|G 20/1.60A/F|0430800000|A.23|H0,5/12D W|9019000000|J.24|H1,0/15 ZH GE|9037260000|J.28|
|EP 2 SAKG46/35 HP/DBR|0180700000|A.44|G 20/1.60A/F|0430800000|A.22|H0,5/12D W|9019000000|J.26|H1,0/15 ZH GE SV|9018530000|J.28|
|EP 2 SAKG46/35 HP/DBR|0180700000|I.4|G 20/1.60A/F|0430800000|A.28|H0,5/14 OR|0690700000|J.22|H1,0/15D ZH R|9037440000|J.29|
|EP 2 SAKG46/35 HP/DBR|0180700000|A.42|G 20/1.60A/F|0430800000|B.26|H0,5/14 OR BD|9004270000|J.23|H1,0/15D ZH R|9037440000|J.30|
|EP 2 SAKG46/35 HP/DBR|0180700000|A.43|G 20/2.00A/F|0430900000|A.28|H0,5/14 OR BD GSP|9005810000|J.23|H1,0/15D ZH R SV|9018540000|J.29|
|EP 2 SAKG46/35 HP/TF/GE|0180800000|A.44|G 20/2.00A/F|0430900000|B.21|H0,5/14 OR SV|9026060000|J.22|H1,0/15D ZH R SV|9018540000|J.30|
|EP 2 SAKG46/35 HP/TF/GE|0180800000|A.47|G 20/2.00A/F|0430900000|B.20|H0,5/14D W|9019010000|J.26|H1,0/15S ZH GE|9018690000|J.28|
|EP 2 SAKG46/35 HP/TF/GE|0180800000|A.45|G 20/2.00A/F|0430900000|A.23|H0,5/14D W|9019010000|J.24|H1,0/15S ZH GE SV|9018650000|J.28|
|EP 2 SAKG46/35 HP/TF/GE|0180800000|A.46|G 20/2.00A/F|0430900000|B.26|H0,5/14D W BD|9004280000|J.24|H1,0/16 GE|9025950000|J.22|
|EP 2 SAKG46/35 HP/TF/GE|0180800000|I.4|G 20/2.00A/F|0430900000|A.22|H0,5/14D W BD|9004280000|J.26|H1,0/16 GE SV|9028320000|J.22|
|EP 2 SAKG46/35 HP/TF/GE|0180800000|A.43|G 20/2.50A/F|0431000000|B.20|H0,5/14D W BD GSP|9005860000|J.27|H1,0/16D R|9019100000|J.24|
|EP 2 SAKG46/35 HP/TF/GE|0180800000|A.42|G 20/2.50A/F|0431000000|A.22|H0,5/14D W BD GSP|9005860000|J.25|H1,0/16D R|9019100000|J.26|
|EP 2/BW SAKG46/32 HP/DB|0271900000|I.5|G 20/2.50A/F|0431000000|B.26|H0,5/14D W SV|9019400000|J.24|H1,0/18 GE|9025930000|J.22|
|EP 2/BW SAKG46/35 HP/DBR|0182000000|I.5|G 20/2.50A/F|0431000000|A.28|H0,5/14D W SV|9019400000|J.26|H1,0/18 GE SV|9028340000|J.22|
|ESCH 1 M|0280300000|H.3|G 20/2.50A/F|0431000000|B.21|H0,5/14S OR|9004560000|J.32|H1,0/18D R|9019110000|J.26|
|ESO 15 BOGEN DIN A4|1636510000|K.19|G 20/2.50A/F|0431000000|A.23|H0,5/14S W|9004590000|J.32|H1,0/18D R|9019110000|J.24|
|ESO 5 DIN A4 GELB BOG.|1631350000|K.17|G 20/3.15A/F|0431100000|B.20|H0,5/15 ZH OR|9037200000|J.30|H1,0/20 ZH GE|9037270000|J.28|
|ESO 5 DIN A4 WEISS BOG.|1607710000|K.17|G 20/3.15A/F|0431100000|A.28|H0,5/15 ZH OR|9037200000|J.28|H1,0/20 ZH GE SV|9004910000|J.28|
|ESO 5 POLY.GELB A4-BOG.|1670380000|K.17|G 20/3.15A/F|0431100000|A.22|H0,5/15 ZH OR SV|9004440000|J.28|H1,0/20D R ZH SV|9004760000|J.30|
|ESO 5 POLY.WEISS A4-BOG.|1670370000|K.17|G 20/3.15A/F|0431100000|B.21|H0,5/15D ZH W|9037380000|J.29|H1,0/20D R ZH SV|9004760000|J.29|
|ESO 5 S DIN A4-BOGEN|1631920000|K.17|G 20/3.15A/F|0431100000|A.23|H0,5/15D ZH W SV|9004780000|J.29|H1,0/20D ZH R|9037450000|J.30|
|ESO 7 A4-BOGEN GELB|1634780000|K.17|G 20/3.15A/F|0431100000|B.26|H0,5/16 DS Weiß|9202910000|J.32|H1,0/20D ZH R|9037450000|J.29|
|ESO 7 A4-BOGEN GELB|1634780000|K.19|G 20/4.00A/F|0431200000|B.26|H0,5/16 OR|9025870000|J.22|H1,0/25,6 ZH GE|9037280000|J.28|
|ESO 7 A4-BOGEN WEISS|1607720000|K.17|G 20/4.00A/F|0431200000|B.20|H0,5/16 OR|9025870000|J.14|H1,0/25,6D ZH R|9037460000|J.29|
|ESO 7 A4-BOGEN WEISS|1607720000|K.19|G 20/4.00A/F|0431200000|A.22|H0,5/16 OR SV|9028270000|J.22|H1,0/25,6D ZH R|9037460000|J.30|
|ESO 7 POLY.GELB A4-BOG.|1670400000|K.17|G 20/4.00A/F|0431200000|A.28|H0,5/16,5 ZH OR|9037210000|J.30|H1,0/6|0372600000|J.33|
|ESO 7 POLY.GELB A4-BOG.|1670400000|K.19|G 20/4.00A/F|0431200000|A.23|H0,5/16,5 ZH OR|9037210000|J.28|H1,5/10|0186500000|J.33|
|ESO 7 POLY.WEISS A4-BOG.|1670390000|K.19|G 20/4.00A/F|0431200000|B.21|H0,5/16,5D ZH W|9037390000|J.29|H1,5/12|9004060000|J.33|
|ESO 7 POLY.WEISS A4-BOG.|1670390000|K.17|G 20/5.00A/F|0431300000|B.21|H0,5/16D W|9019020000|J.26|H1,5/12S R|9025690000|J.32|
|EW 15|0382860000|H.13|G 20/5.00A/F|0431300000|B.26|H0,5/16D W|9019020000|J.24|H1,5/14 R|0463100000|J.22|
|EW 15|0382860000|E.3|G 20/5.00A/F|0431300000|B.20|H0,5/18,4D ZH W|9037400000|J.29|H1,5/14 R BD|9004340000|J.23|
|EW 15|0382860000|E.2|G 20/5.00A/F|0431300000|A.28|H0,5/18,5 ZH OR|9037220000|J.28|H1,5/14 R BD GSP|9005840000|J.23|
|EW 15/2|1071900000|H.13|G 20/5.00A/F|0431300000|A.23|H0,5/18,5 ZH OR|9037220000|J.30|H1,5/14 R SV|9026090000|J.22|
|EW 35|0383560000|A.56|G 20/5.00A/F|0431300000|A.22|H0,5/6|0282600000|J.33|H1,5/14D SW|9019120000|J.26|
|EW 35|0383560000|C.8|G 20/6.30A/F|0431400000|A.28|H0,75/10|0542500000|J.33|H1,5/14D SW|9019120000|J.24|
|EW 35|0383560000|H.13|G 20/6.30A/F|0431400000|B.26|H0,75/12 W|0409600000|J.22|H1,5/14D SW BD|9004350000|J.24|
|EW 35|0383560000|A.57|G 20/6.30A/F|0431400000|B.20|H0,75/12 W SV|9028280000|J.22|H1,5/14D SW BD|9004350000|J.26|
|EW 35 GR 7032|0383530000|H.13|G 20/6.30A/F|0431400000|B.21|H0,75/12D GR|9019030000|J.24|H1,5/14D SW BD GSP|9005890000|J.25|
|EW 35/SCHA/M3|0258660000|I.12|G 20/6.30A/F|0431400000|A.22|H0,75/12T HBL|9021030000|J.26|H1,5/14D SW BD GSP|9005890000|J.27|
|EWK 1|0206160000|H.13|G 25/0.25A/M GE|0546900000|B.26|H0,75/14 GRAU BD GSP|9005870000|J.25|H1,5/14D SW SV|9019430000|J.24|
|EWK 1|0206160000|B.62|G 25/0.25A/M GE|0546900000|A.28|H0,75/14 W|0462900000|J.22|H1,5/14D SW SV|9019430000|J.26|
|EWK 1|0206160000|C.8|G 25/0.50A/M WS|0510300000|A.28|H0,75/14 W BD|9004290000|J.23|H1,5/14DS SW SV|9028360000|J.32|
|EWK 1 ALT|0495160000|H.13|G 25/0.50A/M WS|0510300000|B.26|H0,75/14 W BD GSP|9005820000|J.23|H1,5/14S R|9025980000|J.32|
|EWK 2|0199360000|H.13|G 25/0.80A/M GR|0646400000|A.28|H0,75/14 W SV|9026070000|J.22|H1,5/14S R SV|9025720000|J.32|
|EWK 2/SCHA/M3/L|0258760000|I.12|G 25/0.80A/M GR|0646400000|B.26|H0,75/14D GR|9019040000|J.24|H1,5/14S SW|9025240000|J.32|
|EWK AKA 2.5|0348660000|H.13|G 25/1.00A/M RT|0265800000|B.26|H0,75/14D GR BD|9004300000|J.24|H1,5/16 R|0635100000|J.22|
|**F**|||G 25/1.00A/M RT<br>G 25/10.0A/M RT<br>G 25/10.0A/M RT|0265800000<br>0193100000<br>0193100000|A.28<br>B.26<br>A.28|H0,75/14D GR SV<br>H0,75/14S W<br>H0,75/14S W SV|9019410000<br>9025960000<br>9025700000|J.24<br>J.32<br>J.32|H1,5/16 R SV<br>H1,5/16 ZH R<br>H1,5/16 ZH R SV|9028350000<br>9037290000<br>9004410000|J.22<br>J.28<br>J.28|
|FK 4|1678650000|I.14|G 25/2.00A/F BL|0192700000|A.28|H0,75/14T BL BD GSP|9005900000|J.27|H1,5/16D SW|9019130000|J.24|
|FKSC M5X8 D9/SW2.5|0295900000|H.14|G 25/2.00A/F BL|0192700000|B.26|H0,75/14T HBL BD|9004310000|J.26|H1,5/16D SW|9019130000|J.26|
|FKSC M6X12 D9/SW3|0353500000|H.14|G 25/4.00A/F BR|0192800000|A.28|H0,75/14T HBL SV|9021230000|J.26|H1,5/16D ZH SW|9037470000|J.30|
|FKSC M6X8 D9/SW3|0642600000|H.14|G 25/4.00A/F BR|0192800000|B.26|H0,75/14TS HBL|9018550000|J.32|H1,5/16D ZH SW|9037470000|J.29|
|FM 4.2/TS35|1724580000|H.15|G 25/6.30A/F GN|0192900000|A.28|H0,75/15 ZH W|9037230000|J.28|H1,5/16D ZH SW SV|9004420000|J.29|
|FM 4/TS35|0687900000|G.10|G 25/6.30A/F GN|0192900000|B.26|H0,75/15 ZH W SV|9018510000|J.28|H1,5/16D ZH SW SV|9004420000|J.30|
|FM 4/TS35|0687900000|H.15|GZ 0.5A/F|0533800000|A.28|H0,75/15D ZH GR|9037410000|J.29|H1,5/17,5X SW SV|9006590000|J.31|
|FM 5/TS35|0636800000|H.15|GZ 0.5A/F|0533800000|B.26|H0,75/15D ZH GR SV|9018520000|J.29|H1,5/18|9004070000|J.33|
|FM 6/TS35|0636900000|H.15|GZ 1.0A/F|0525500000|B.26|H0,75/15T ZH HBL|9037610000|J.30|H1,5/18D SW|9019140000|J.26|
|FZS 2/4 RT/80 SAKT4|1276300000|I.14|GZ 1.0A/F|0525500000|A.23|H0,75/16 W|9025860000|J.22|H1,5/18D SW|9019140000|J.24|
||||GZ 1.0A/F|0525500000|A.28|H0,75/16 W SV|9028290000|J.22|H1,5/19,5X SW SV|9006630000|J.31|
||||GZ 10.0A|0293900000|B.26|H0,75/16D GR|9019050000|J.24|H1,5/20 ZH R|9037300000|J.28|
||||GZ 10.0A|0293900000|A.28|H0,75/16T HBL|9021050000|J.26|H1,5/20 ZH R SV|9004920000|J.28|
**X**
**X.6**
|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|H1,5/20D SW ZH SV|9004750000|J.30|H2,5/26,5D ZH BL|9037520000|J.29|IH 2.8 DB|0386060000|B.42|KSKM 3/35 GZ 1 1/4X1/4|9509620000|A.23|
|H1,5/20D SW ZH SV|9004750000|J.29|H2,5/26,5T ZH GR|9037660000|J.30|IH 2.8 DB|0386060000|E.9|KST 10|9501330000|B.55|
|H1,5/20D ZH SW|9037480000|J.29|H2,5/7|0373000000|J.33|IH 2.8 DB|0386060000|B.43|KST 10/35 M10X39|9506960000|A.49|
|H1,5/20D ZH SW|9037480000|J.30|H25,0/15|0124400000|J.33|IH 2.8 DB|0386060000|B.44|KST 10/35 M10X39|9528330000|A.49|
|H1,5/24 R|0565600000|J.22|H25,0/18|0375300000|J.33|IH 2.8 DB|0386060000|B.36|KST 12|9501340000|B.55|
|H1,5/24D SW|9019150000|J.24|H25,0/25|9004170000|J.33|IH 2.8 DB|0386060000|A.38|KST 12/35 M12X37|9506970000|A.49|
|H1,5/24D SW|9019150000|J.26|H25,0/30 BR|0317000000|J.22|IH 2.8 DB|0386060000|A.39|KST 12/35 M12X37|9528340000|A.49|
|H1,5/24D SW SV|9004140000|J.26|H25,0/30D 16 GE|9019280000|J.24|IH 6.3 WEM GE|0386260000|B.37|KST 5|9503370000|B.54|
|H1,5/24D SW SV<br>H1,5/25,6 ZH R<br>H1,5/25,6D ZH SW<br>H1,5/25,6D ZH SW|9004140000<br>9037310000<br>9037490000<br>9037490000|J.24<br>J.28<br>J.29<br>J.30|H25,0/30T SW<br>H25,0/32<br>H25,0/36 BR<br>H25,0/36D GE|9021190000<br>9004180000<br>0317100000<br>9019300000|J.26<br>J.33<br>J.22<br>J.24|IH 6.3 WEM GE<br>IH 6.3 WEM GE<br>IH 6.3 WEM GE<br>IH 6.3 WEM GE|0386260000<br>0386260000<br>0386260000<br>0386260000|A.38<br>B.36<br>E.9<br>B.43|KST 5/35 M5X18<br>KST 6<br>KST 6/35 M6X22<br>KST 8|9528300000<br>9501310000<br>9506940000<br>9501320000|A.48<br>B.54<br>A.48<br>B.55|
|H1,5/7|0372700000|J.33|H25,0/36T SW|9021200000|J.26|IH 6.3 WEM GE|0386260000|A.36|KST 8/35 M8X30|9506950000|A.49|
|H10,0/12|0282900000|J.33|H35,0/18|0368900000|J.33|IH 6.3 WEM GE|0386260000|A.39|KST 8/35 M8X30|9528320000|A.49|
|H10,0/15|0124800000|J.33|H35,0/25|9004190000|J.33|IH 6.3 WEM GE|0386260000|B.44|KT 12|9002660000|J.2|
|H10,0/18|0379300000|J.33|H35,0/30 BE|0317200000|J.22|IH 6.3 WEM GE|0386260000|E.8|KT 8|9002650000|J.2|
|H10,0/22 EB|0534200000|J.22|H35,0/30D 16 R|9019310000|J.24|IH 6.3 WEM GE|0386260000|A.37|KT ZQV|9002170000|J.3|
|H10,0/22D R|9019240000|J.24|H35,0/30D R|9019320000|J.24|IH 6.3 WEM GE|0386260000|B.42||||
|H10,0/22T BR<br>H10,0/24,5X R SV|9021150000<br>9006830000|J.26<br>J.31|H35,0/30S<br>H35,0/32|9451000000<br>9004200000|J.33<br>J.33|IK 16/ZB16 BL<br>IK 16/ZB16 GG|0502980000<br>0502960000|H.6<br>H.6|**L**|||
|H10,0/24DS ZH R|9018880000|J.29|H35,0/39 BE|0317300000|J.22|IK 35/ZB35 BL|0502780000|H.6|LADEGERAET DMS 3|9007460000|J.10|
|H10,0/26 ZH EB|9037340000|J.28|H35,0/39D R|9019330000|J.24|IK 4 BL ZB4|0475480000|H.6||||
|H10,0/26 ZH EB SV<br>H10,0/26D R ZH SV|9004940000<br>9004710000|J.28<br>J.29|H4,0/12<br>H4,0/15|0244100000<br>9004100000|J.33<br>J.33|IK 4 GG ZB4<br>IK 6 BL ZBE6K|0475460000<br>0526080000|H.6<br>H.6|**M**|||
|H10,0/26D ZH R|9037570000|J.29|H4,0/17D GR|9019190000|J.24|IK 6 GG ZBE6K|0526060000|H.6|Magazin SMark Laser|1782880000|K.21|
|H10,0/26T ZH BR|9037710000|J.30|H4,0/17D GR|9019190000|J.22|IS 2 KG|1806630000|J.20|MB M3/M5 CRM|0503500000|H.15|
|H10,0/26T ZH BR SV|9005170000|J.30|H4,0/17T OR|9021100000|J.26|IS 3 KG|1806650000|J.20|MB M5/M3 SW|0553400000|H.15|
|H10,0/28 EB|0565800000|J.22|H4,0/18|9004110000|J.33|IS 4 DIN 6911|0485100000|J.20|MB M6/M4 GR|0334900000|H.15|
|H10,0/28D R|9019250000|J.24|H4,0/19,5X GR SV|9006750000|J.31|IS 4 KG|1806660000|J.20|MC-Mobilo 110V/220V|1741260001|K.25|
|H10,0/28T BR|9021160000|J.26|H4,0/20D GR|9019200000|J.22|IS 6 DIN 6911|0407900000|J.20|MC-MOBILO AUFN. SF 4-6|1802180000|K.25|
|H10,0/30 ZH EB|9037350000|J.28|H4,0/20D GR|9019200000|J.24|IS 8 DIN 6911|0235000000|J.20|MCP AP|1924360000|K.24|
|H10,0/30D ZH R|9037580000|J.29|H4,0/20T OR|9021110000|J.26|ISPF QB58 BL|0546080000|I.13|MCP AP LABLES|1924370000|K.24|
|H10,0/30T ZH BR|9037720000|J.30|H4,0/22D ZH GR|9037530000|J.29|ISPF QB58 RT|0546040000|<br>I.13|MCP AP SF4-6|1924310000|K.24|
|H10/24S ZH EB|9018860000|J.28|H4,0/22D ZH GR|9037530000|J.28|ISPF QB58 SW|0546000000|<br>I.13|MCP COVER|1924350000|K.24|
|H10/30DS ZH R|9018890000|J.29|H4,0/22T ZH OR|9037670000|J.30|ISPF QB75 BL|0526780000|I.13|MCP EP|1935130000|K.24|
|H10/30S ZH EB|9018870000|J.28|H4,0/22T ZH OR SV|9018590000|J.30|ISPF QB75 RT|0526760000|<br>I.13|MCP KLEBESTREIFEN|1924320000|K.24|
|H120,0/32|9036240000|J.33|H4,0/26D GR|9019210000|J.24|ISPF QB75 SW|0526700000|<br>I.13|MCP PLUS|1925000000|K.23|
|H120,0/50 BL|9028220000|J.22|H4,0/26D GR|9019210000|J.22||||MEHA OB/UN 16² SPX 3|9054080000|J.4|
|H150,0/32<br>H150,0/54 GE|9036250000<br>9028230000|J.33<br>J.22|H4,0/26T OR<br>H4,0/28D ZH GR|9021120000<br>9037540000|J.26<br>J.29|**K**|||MEHA OB/UN 6² SPX 3<br>MF 2/12 1X2.8/1.6|9054030000<br>0241760000|J.4<br>F.2|
|H16,0/12|0492500000|J.33|H4,0/28D ZH GR|9037540000|J.28|KDKS 1/32|9503300000|B.21|MK 10/14|0370160000|F.3|
|H16,0/15|0124300000|J.33|H4,0/28T ZH OR|9037680000|J.30|KDKS 1/35|9503310000|A.23|MK 2/12|0241260000|F.2|
|H16,0/18|0375200000|J.33|H4,0/9|0373100000|J.33|KDKS1/EN LD 115VAC|8142840000|C.7|MK 3/10|0274620000|F.2|
|H16,0/24 GN|0565900000|J.22|H4/17 GR SV|9026010000|J.22|KDKS1/EN LD 230VAC|8148910000|C.7|MK 3/10/E|7906190000|F.6|
|H16,0/24D BL|9019260000|J.24|H4/17 GR SV|9026010000|J.24|KDKS1/EN LD 24 VAC|8148930000|C.7|MK 3/11/E|7906200000|F.6|
|H16,0/24T W|9021170000|J.26|H4/17T OR SV|9021250000|J.26|KDKS1/EN LD 24VDC|8146450000|C.7|MK 3/12|0243520000|F.2|
|H16,0/25|9004150000|J.33|H4/22D ZH GR SV|9004730000|J.29|KDKS1/EN LD 48 VAC|8148920000|C.7|MK 3/12/E|7906210000|F.6|
|H16,0/25,5X BL SV|9006870000|J.31|H4/22D ZH GR SV|9004730000|J.28|KISC M2.5X11/4.5 AKZ1.5|0400100000|I.9|MK 3/2|0273820000|F.2|
|H16,0/28 GN|0566000000|J.22|H50,0/18|9004210000|J.33|KISC M3X15/6 SAK2.5|0359000000|I.9|MK 3/2/E|7906110000|F.6|
|H16,0/28D BL|9019270000|J.24|H50,0/25|9025880000|J.33|KISC M3X15/6 SAK2.5|0359000000|I.10|MK 3/3|0273920000|F.2|
|H16,0/28T W|9021180000|J.26|H50,0/32|9004220000|J.33|KISC M3X15/6 SAK2.5 CU5|0377200000|B.32|MK 3/3/E|7906120000|F.6|
|H16,0/29 ZH GN|9037360000|J.28|H50/36 OLIV|0444200000|J.22|KISC M3X15/6 SAK2.5 CU5|0377200000|I.12|MK 3/4|0274020000|F.2|
|H16,0/29D ZH BL|9037590000|J.29|H50/36D BL|9019340000|J.24|KISC M3X15/6 SAK2.5 CU5|0377200000|A.33|MK 3/4/E|7906130000|F.6|
|H16,0/29T ZH W|9037730000|J.30|H50/40D BL|9019350000|J.24|KISC M3X20 SAK10 CU5|0377100000|A.33|MK 3/5|0274120000|F.2|
|H16,0/32|9004160000|J.33|H6,0,0/20T GN|9021130000|J.26|KISC M3X20 SAK10 CU5|0377100000|I.12|MK 3/5/E|7906140000|F.6|
|H16,0/38 ZH GN|9037370000|J.28|H6,0/10|9004120000|J.33|KISC M3X20 SAK10 CU5|0377100000|A.32|MK 3/6|0274220000|F.2|
|H16,0/38D ZH BL|9037600000|J.29|H6,0/12|0191900000|J.33|KISC M3X20 SAK10 CU5|0377100000|B.31|MK 3/6/E|7906150000|F.6|
|H16,0/38T ZH W|9037740000|J.30|H6,0/15|0124700000|J.33|KISC M3X20 SAK10 CU5|0377100000|B.32|MK 3/7|0274320000|F.2|
|H185,0/32|9036260000|J.33|H6,0/18|9004130000|J.33|KISC M3X20 SAK10 CU5|0377100000|I.21|MK 3/7/E|7906160000|F.6|
|H2,5/10|9004080000|J.33|H6,0/20 SW|0533500000|J.22|KISC M3X20.5/10 EK4|0303000000|D.3|MK 3/8|0274420000|F.2|
|H2,5/12|0186100000|J.33|H6,0/20D GE|9019220000|J.24|KISC M3X20.5/10 EK4|0303000000|I.10|MK 3/8/E|7906170000|F.6|
|H2,5/12DS BL|9028490000|J.32|H6,0/23,0X GE SV|9006790000|J.31|KISC M3X20.5/10 EK4|0303000000|D.2|MK 3/9|0274520000|F.2|
|H2,5/12TS GR|9036200000|J.32|H6,0/25 ZH SW|9037320000|J.28|KISC M3X20.5/10 EK4|0303000000|B.28|MK 3/9/E|7906180000|F.6|
|H2,5/14 BL SV|9026100000|J.22|H6,0/25 ZH SW SV|9004930000|J.28|KISC M3X20.5/10 EK4|0303000000|I.9|MK 4/16|0244220000|F.3|
|H2,5/14 BL SV|9026100000|J.24|H6,0/25D ZH GE|9037550000|J.29|KISC M3X20.5/10 EK4|0303000000|A.11|MK 5/2 O.DE|0243820000|F.4|
|H2,5/14D BL|9019160000|J.22|H6,0/25T ZH GN|9037690000|J.30|KISC M3X6 SAKS1|0346200000|<br>I.9|MK 6/2|0620420000|F.3|
|H2,5/14D BL|9019160000|J.24|H6,0/25T ZH GN SV|9005160000|J.30|KISC M5X50/26 SAK95|0630200000|B.9|MK 6/2/E|7906220000|F.7|
|H2,5/14D BL BD|9004360000|J.23|H6,0/26 SW|0565700000|J.22|KISC M5X50/26 SAK95|0630200000|A.10|MK 6/3|0620320000|F.3|
|H2,5/14D BL BD|9004360000|J.24|H6,0/26D GE|9019230000|J.24|KISC M5X50/26 SAK95|0630200000|I.9|MK 6/3/E|7906230000|F.7|
|H2,5/14D BL BD GSP|9005850000|J.23|H6,0/29 ZH SW|9037330000|J.28|KLBUE 10-20|1600490000|G.4|MK 6/4|0620220000|F.3|
|H2,5/14D BL BD GSP|9005850000|J.25|H6,0/29D ZH GE|9037560000|J.29|KLBUE 10-20 CPF|1752701001|G.11|MK 6/4/E|7906240000|F.7|
|H2,5/14S BL|1333100000|J.32|H6,0/29T ZH GN|9037700000|J.30|KLBUE 10-20 SC|1712321001|G.8|MK 6/5/E|7906250000|F.7|
|H2,5/14T GR|9021070000|J.26|H6/25D ZH GE SV|9004720000|J.29|KLBUE 15-32|1716300000|G.4|MK 6/6|0620120000|F.3|
|H2,5/14T GR BD|9004370000|J.26|H6/26T GN|9021140000|J.26|KLBUE 15-32 CPF|1752711001|G.11|MK 6/6/E|7906260000|F.7|
|H2,5/14T GR BD GSP|9005910000|J.27|H70,0/25|9004230000|J.33|KLBUE 15-32 SC|1718341001|G.8|MOFU 35|0495660000|H.15|
|H2,5/14T GR SV|9021240000|J.26|H70,0/32|9004240000|J.33|KLBUE 3-8|1600480000|G.4|MOFU 35/LO/1|0646260000|H.15|
|H2,5/14TS GR|9426770000|J.32|H70,0/40 GE|9028200000|J.22|KLBUE 3-8 CPF SS|1752681001|G.11|M-PRINT PRO|1905490000|K.26|
|H2,5/16DS BL|9036220000|J.32|H95,0/25|9004250000|J.33|KLBUE 3-8 SC|1692261001|G.8|M-PRINT PRO|1905490000|K.24|
|H2,5/17,5X BL SV|9006670000|J.31|H95,0/32|9004260000|J.33|KLBUE 4-13.5|1592810000|G.4|M-PRINT PRO ADVANCED|1905500000|K.26|
|H2,5/18|9004090000|J.33|H95,0/44 R|9028210000|J.22|KLBUE 4-13.5 CPF|1752691001|G.11||||
|H2,5/18,5D ZH BL<br>H2,5/18,5D ZH BL|9037500000<br>9037500000|J.28<br>J.29|HP 1 ADP1<br>HP 2 ADP2|0485560000<br>0485660000|I.16<br>I.16|KLBUE 4-13.5 SC<br>KLBUE CO 1|1712311001<br>1753311001|G.8<br>G.5|**N**|||
|H2,5/18,5D ZH BL SV|9004430000|J.28|HP 3 ADP3|0485760000|I.16|KLBUE CO 2|1752131001|G.5|NSCH 1M|0280200000|H.3|
|H2,5/18,5D ZH BL SV|9004430000|J.29|HP 4 ADP3|0485860000|I.16|KLBUE CO 3|1749151001|G.5|NT 10/35 10X3 BL|0471880000|A.31|
|H2,5/18,5T ZH GR|9037640000|J.30|HP 7 TSK31.5|0258260000|I.16|KLBUE CO 4|1749161001|G.5|NT 16/35 10X3 BL|0499280000|A.31|
|H2,5/18.5T ZH GR SV|9018580000|J.30|HP 8 ADP 1|0258360000|I.16|KLBUE CO 5|1755081001|G.5|NT 2.5/35 10X3 BL|0471780000|A.30|
|H2,5/18D BL|9019170000|J.22|HP EK132/2 AD250|0634300000|I.18|KLBUE SH1|0635960000|H.4|NT 6/35 10X3 KRG/BL|0501470000|A.30|
|H2,5/18D BL|9019170000|J.24|HP NT16/10X3|1266380000|A.31|KMVF LI 6.3 EP/SW|0249100000|D.8||||
|H2,5/18T GR<br>H2,5/20,5 T ZH GR SV|9021080000<br>9005150000|J.26<br>J.30|HP NT2.5 BL<br>HP NT6/10 BL|0352080000<br>0352880000|A.30<br>A.31|KMVF RE 6.3 EP/SW<br>KMVT LI 2.4 EP/SW|0249200000<br>0249300000|D.8<br>D.9|**P**|||
|H2,5/20,5D BL ZH SV|9004740000|J.29|HP NT6/10 BL|0352880000|A.30|KMVT RE 2.4 EP/SW|0249400000|D.9|P 14/10 D01 RT SAKS4|0328700000|A.26|
|H2,5/20,5D BL ZH SV|9004740000|J.28|HTG 58|9012000000|I.14|KOHUE ASK1|0553300000|A.23|P 14/10 D01 RT SAKS4|0328700000|B.27|
|H2,5/20,5D ZH BL|9037510000|J.29|HTI 15|9014400000|J.35|KS 10 O.D10|0141620000|F.4|P 14/10 D01 RT SAKS4|0328700000|B.24|
|H2,5/20,5D ZH BL|9037510000|J.28||||KS 2 O.D2|0134420000|F.4|P 14/10 D01 RT SAKS4|0328700000|A.29|
|H2,5/20,5T ZH GR<br>H2,5/21,5X BL SV|9037650000<br>9006710000|J.30<br>J.31|**I**|||KS 4 O.D4<br>KS 6 O.D6|0140320000<br>0140620000|F.4<br>F.4|P 14/2 D01 RS SAKS4<br>P 14/2 D01 RS SAKS4|0138000000<br>0138000000|A.26<br>B.24|
|H2,5/24D BL|9019180000|J.22|IH 2.8 DB|0386060000|A.37|KSKM 1/32 G20|9509570000|B.20|P 14/2 D01 RS SAKS4|0138000000|A.29|
|H2,5/24D BL|9019180000|J.24|IH 2.8 DB|0386060000|A.36|KSKM 1/35 G20|9509600000|A.22|P 14/2 D01 RS SAKS4|0138000000|B.27|
|H2,5/24T GR|9021090000|J.26|IH 2.8 DB|0386060000|B.37|KSKM 2/32 GZ 1X1/4|9509580000|B.20|P 14/4 D01 BR SAKS4|0138100000|A.29|
|H2,5/26,5D ZH BL|9037520000|J.28|IH 2.8 DB|0386060000|E.8|KSKM 2/35 GZ 1X1/4|9509610000|A.22|P 14/4 D01 BR SAKS4|0138100000|B.24|
**X**
**X.7**
**X**
|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|P 14/4 D01 BR SAKS4|0138100000|A.26|PS 2.3 RT|0180400000|E.11|Q 10 SAK10|0457400000|A.8|Q 2 SAK4|0336700000|A.37|
|P 14/4 D01 BR SAKS4|0138100000|B.27|PS 2.3 RT|0180400000|B.59|Q 10 SAK10|0457400000|B.3|Q 2 SAK4|0336700000|B.3|
|P 14/6 D01 GN SAKS4|0328600000|B.27|PS 2.3 RT|0180400000|B.6|Q 10 SAK10|0457400000|B.7|Q 2 SAK4|0336700000|C.5|
|P 14/6 D01 GN SAKS4|0328600000|A.26|PS 2.3 RT|0180400000|A.40|Q 10 SAK16|0457800000|A.9|Q 2 SAK4|0336700000|I.9|
|P 14/6 D01 GN SAKS4|0328600000|B.24|PS 2.3 RT|0180400000|B.18|Q 10 SAK16|0457800000|I.9|Q 2 SAK4|0336700000|B.36|
|P 14/6 D01 GN SAKS4|0328600000|A.29|PS 2.3 RT|0180400000|A.39|Q 10 SAK16|0457800000|C.3|Q 2 SAK4|0336700000|A.36|
|P 16/10 RT SAKS2|0208900000|B.24|PS 2.3 RT|0180400000|B.58|Q 10 SAK16|0457800000|A.4|Q 2 SAK4|0336700000|A.3|
|P 16/10 RT SAKS2|0208900000|B.27|PS 2.3 RT|0180400000|B.60|Q 10 SAK16|0457800000|B.4|Q 2 SAK4|0336700000|D.6|
|P 16/10 RT SAKS2<br>P 16/10 RT SAKS2<br>P 16/16 GR SAKS2<br>P 16/16 GR SAKS2|0208900000<br>0208900000<br>0209000000<br>0209000000|A.29<br>A.26<br>A.26<br>A.29|PS 2.3 RT<br>PS 2.3 RT<br>PS 2.3 RT<br>PS 2.3 RT|0180400000<br>0180400000<br>0180400000<br>0180400000|A.36<br>A.37<br>B.39<br>B.38|Q 10 SAK16<br>Q 10 SAK2.5<br>Q 10 SAK2.5<br>Q 10 SAK2.5|0457800000<br>0368700000<br>0368700000<br>0368700000|B.7<br>I.9<br>A.2<br>A.7|Q 2 SAK4<br>Q 2 SAK4<br>Q 2 SAK4<br>Q 2 SAK4|0336700000<br>0336700000<br>0336700000<br>0336700000|A.7<br>B.6<br>B.42<br>B.43|
|P 16/16 GR SAKS2|0209000000|B.24|PS 2.3 RT|0180400000|B.37|Q 10 SAK2.5|0368700000|B.2|Q 2 SAK6N|0456700000|I.21|
|P 16/16 GR SAKS2|0209000000|B.27|PS 2.3 RT|0180400000|A.20|Q 10 SAK2.5|0368700000|B.45|Q 2 SAK6N|0456700000|I.9|
|P 16/20 BL SAKS2|0209100000|B.27|PS 2.3 RT|0180400000|B.36|Q 10 SAK2.5|0368700000|B.38|Q 2 SAK6N|0456700000|A.8|
|P 16/20 BL SAKS2|0209100000|B.24|PS 2.3 RT|0180400000|B.61|Q 10 SAK2.5|0368700000|B.39|Q 2 SAK6N|0456700000|B.3|
|P 16/20 BL SAKS2|0209100000|A.26|PS 2.3 RT|0180400000|A.12|Q 10 SAK2.5|0368700000|B.6|Q 2 SAK6N|0456700000|C.3|
|P 16/20 BL SAKS2|0209100000|A.29|PS 2.3 RT|0180400000|B.32|Q 10 SAK2.5|0368700000|A.40|Q 2 SAK6N|0456700000|A.3|
|P 18/20 D02 BL SAKS5|0361800000|A.29|PS 2.3 RT|0180400000|C.2|Q 10 SAK2.5|0368700000|C.2|Q 2 SAK6N|0456700000|B.7|
|P 18/20 D02 BL SAKS5|0361800000|B.25|PS 2.3 RT|0180400000|B.16|Q 10 SAK4|0368800000|B.3|Q 2 SAKD2.5N|0367800000|B.2|
|P 18/20 D02 BL SAKS5|0361800000|A.27|PS 2.3 RT|0180400000|B.10|Q 10 SAK4|0368800000|B.6|Q 2 SAKD2.5N|0367800000|A.2|
|P 18/20 D02 BL SAKS5|0361800000|B.27|PS 2.3 RT|0180400000|B.17|Q 10 SAK4|0368800000|B.36|Q 3 AKZ1.5|0368300000|I.11|
|P 18/25 D02 GE SAKS5|0361900000|B.25|PS 2.3 RT|0180400000|A.7|Q 10 SAK4|0368800000|C.2|Q 3 AKZ1.5|0368300000|E.10|
|P 18/25 D02 GE SAKS5|0361900000|B.27|PS 2.3 RT|0180400000|E.13|Q 10 SAK4|0368800000|A.3|Q 3 AKZ1.5|0368300000|E.2|
|P 18/25 D02 GE SAKS5|0361900000|A.29|PS 2.3 RT|0180400000|C.5|Q 10 SAK4|0368800000|B.42|Q 3 AKZ4|0336500000|A.50|
|P 18/25 D02 GE SAKS5|0361900000|A.27|PS 2.3 RT|0180400000|B.11|Q 10 SAK4|0368800000|C.5|Q 3 AKZ4|0336500000|B.10|
|P 18/35 D02 SW SAKS5|0362000000|B.27|PS 2.3 RT|0180400000|E.10|Q 10 SAK4|0368800000|B.43|Q 3 AKZ4|0336500000|B.60|
|P 18/35 D02 SW SAKS5|0362000000|B.25|PS 2.3 RT|0180400000|C.4|Q 10 SAK4|0368800000|I.9|Q 3 AKZ4|0336500000|B.61|
|P 18/35 D02 SW SAKS5|0362000000|A.29|PS 2.3 RT|0180400000|E.12|Q 10 SAK4|0368800000|D.6|Q 3 AKZ4|0336500000|E.10|
|P 18/35 D02 SW SAKS5|0362000000|A.27|PS 4 F.STB 4|0299600000|A.5|Q 10 SAK4|0368800000|A.36|Q 3 AKZ4|0336500000|A.51|
|P 18/50 D02 WS SAKS5|0362100000|B.27|PS 4 F.STB 4|0299600000|B.7|Q 10 SAK4|0368800000|A.37|Q 3 AKZ4|0336500000|E.9|
|P 18/50 D02 WS SAKS5|0362100000|B.25|PS 4 F.STB 4|0299600000|A.6|Q 10 SAK4|0368800000|C.4|Q 3 AKZ4|0336500000|A.13|
|P 18/50 D02 WS SAKS5|0362100000|A.29|PS 4 F.STB 4|0299600000|A.3|Q 10 SAK4|0368800000|A.7|Q 3 AKZ4|0336500000|B.58|
|P 18/50 D02 WS SAKS5|0362100000|A.27|PS 4 F.STB 4|0299600000|D.9|Q 10 SAK6N|0457000000|I.21|Q 3 AKZ4|0336500000|E.3|
|P-CLEANER|1924330000|K.25|PS 4 F.STB 4|0299600000|A.4|Q 10 SAK6N|0457000000|B.3|Q 3 AKZ4|0336500000|A.52|
|P-CLEANER|1924330000|K.24|PS 4 F.STB 4|0299600000|B.4|Q 10 SAK6N|0457000000|C.3|Q 3 AKZ4|0336500000|E.13|
|P-INK|1924340000|K.24|PS 4 F.STB 4|0299600000|A.20|Q 10 SAK6N|0457000000|A.3|Q 3 AKZ4|0336500000|B.59|
|P-INK|1924340000|K.25|PS 4 F.STB 4|0299600000|A.33|Q 10 SAK6N|0457000000|B.7|Q 3 AKZ4|0336500000|B.38|
|PJ PRO TNTK FL|1027080000|K.22|PS 4 F.STB 4|0299600000|B.5|Q 10 SAK6N|0457000000|I.9|Q 3 AKZ4|0336500000|A.12|
|PJ PRO TNTK INK C|1027050000|K.22|PS 4 F.STB 4|0299600000|C.3|Q 10 SAK6N|0457000000|A.8|Q 3 AKZ4|0336500000|E.12|
|PJ PRO TNTK INK K|1027040000|K.22|PS 4 F.STB 4|0299600000|B.19|Q 10 SAKD2.5N|0368100000|B.2|Q 3 AKZ4|0336500000|I.9|
|PJ PRO TNTK INK M|1027060000|K.22|PS 4 F.STB 4|0299600000|B.30|Q 10 SAKD2.5N|0368100000|A.2|Q 3 AKZ4|0336500000|A.39|
|PJ PRO TNTK INK SET BK|1027090000|K.22|PS 4 F.STB 4|0299600000|B.3|Q 2 AKZ1.5|0368200000|I.11|Q 3 AKZ4|0336500000|A.54|
|PJ PRO TNTK INK Y|1027070000|K.22|PS 4 F.STB 4|0299600000|I.14|Q 2 AKZ1.5|0368200000|E.2|Q 3 AKZ4|0336500000|B.11|
|PJ-Clean Unit|4062150000|K.22|PS 4 F.STB 4|0299600000|A.9|Q 2 AKZ1.5|0368200000|E.10|Q 3 AKZ4|0336500000|B.37|
|PJ-PRO TNTK INK SET COL|1027110000|K.22|PS 4 F.STB 4|0299600000|B.8|Q 2 AKZ4|0336400000|E.10|Q 3 AKZ4|0336500000|A.56|
|PLOTTER PEN 0.25 P-INK|1920640000|K.25|PS 4 F.STB 4|0299600000|B.31|Q 2 AKZ4|0336400000|A.39|Q 3 AKZ4|0336500000|A.38|
|PLOTTER PEN 0.25 P-INK|1920640000|K.24|PS 4 F.STB 4|0299600000|B.9|Q 2 AKZ4|0336400000|B.61|Q 3 AKZ4|0336500000|A.53|
|PLOTTER PEN 0.35 P-INK|1920650000|K.24|PS 4 F.STB 4|0299600000|B.32|Q 2 AKZ4|0336400000|A.55|Q 3 AKZ4|0336500000|B.57|
|PLOTTER PEN 0.35 P-INK|1920650000|K.25|PS 4 F.STB 4|0299600000|A.10|Q 2 AKZ4|0336400000|A.56|Q 3 AKZ4|0336500000|A.55|
|PLOTTER PEN 0.50 P-INK|1005710000|K.25|PS 4 F.STB 4|0299600000|D.6|Q 2 AKZ4|0336400000|B.37|Q 3 AKZ4|0336500000|E.11|
|PLOTTER PEN 0.50 P-INK|1005710000|K.24|PS 4 F.STB 4|0299600000|B.29|Q 2 AKZ4|0336400000|B.57|Q 3 AKZ4|0336500000|I.11|
|PLOTTER PEN 0.70 P-INK|1011450000|K.24|PS 4 F.STB 4|0299600000|B.28|Q 2 AKZ4|0336400000|E.11|Q 3 AKZ4|0336500000|B.56|
|PLOTTER PEN 0.70 P-INK|1011450000|K.25|PS 4 F.STB 4|0299600000|C.4|Q 2 AKZ4|0336400000|B.38|Q 3 AKZ4SS|0369100000|I.11|
|Plotterpen 0,18|1768570000|K.25|PS 4 F.STB 4|0299600000|A.32|Q 2 AKZ4|0336400000|E.13|Q 3 AKZ4SS|0369100000|E.8|
|Plotterpen 0,18|1768570000|K.24|PS 4 F.STB 4|0299600000|A.8|Q 2 AKZ4|0336400000|A.12|Q 3 DLI|1312600000|I.11|
|Plotterpen 0,25|1768540000|K.25|PZ 1.5|9005990000|J.35|Q 2 AKZ4|0336400000|B.60|Q 3 SAK10|0457200000|C.3|
|Plotterpen 0,25|1768540000|K.24|PZ 16|9012600000|J.8|Q 2 AKZ4|0336400000|B.10|Q 3 SAK10|0457200000|B.7|
|Plotterpen 0,35|1768550000|K.25|PZ 16|9012600000|J.35|Q 2 AKZ4|0336400000|B.11|Q 3 SAK10|0457200000|A.8|
|Plotterpen 0,35|1768550000|K.24|PZ 3|0567300000|J.7|Q 2 AKZ4|0336400000|E.12|Q 3 SAK10|0457200000|A.3|
|Plotterpen 0,5|1768560000|K.25|PZ 3|0567300000|J.35|Q 2 AKZ4|0336400000|E.9|Q 3 SAK10|0457200000|B.3|
|Plotterpen 0,5|1768560000|K.24|PZ 4|9012500000|J.35|Q 2 AKZ4|0336400000|E.3|Q 3 SAK10|0457200000|I.9|
|PLOTTERPEN 0,7|1011440000|K.25|PZ 4|9012500000|J.6|Q 2 AKZ4|0336400000|A.38|Q 3 SAK16|0457600000|B.4|
|PLOTTERPEN 0,7|1011440000|K.24|PZ 50|9006450000|J.35|Q 2 AKZ4|0336400000|A.50|Q 3 SAK16|0457600000|A.9|
|POSC M3X20 PA/NA|0451300000|I.17|PZ 50|9006450000|J.9|Q 2 AKZ4|0336400000|B.56|Q 3 SAK16|0457600000|C.3|
|PPT/35|3835020000|D.9|PZ 6 HEX|9013650000|J.35|Q 2 AKZ4|0336400000|I.11|Q 3 SAK16|0457600000|B.7|
|PRINT KIT|1686920000|K.25|PZ 6 Roto|9014350000|J.35|Q 2 AKZ4|0336400000|A.51|Q 3 SAK16|0457600000|I.9|
|PRINTJET PRO 115V|1024050000|K.22|PZ 6 Roto|9014350000|J.7|Q 2 AKZ4|0336400000|A.53|Q 3 SAK16|0457600000|A.4|
|PRINTJET PRO 230V|1001180001|K.22|PZ 6/5|9011460000|J.35|Q 2 AKZ4|0336400000|A.52|Q 3 SAK2.5|0337100000|B.6|
|PS 2.0 MC|0310000000|I.14|PZ 6/5|9011460000|J.6|Q 2 AKZ4|0336400000|A.13|Q 3 SAK2.5|0337100000|B.38|
|PS 2.0 OR|0293800000|I.14|PZ ZH 16|9013600000|J.8|Q 2 AKZ4|0336400000|I.9|Q 3 SAK2.5|0337100000|A.2|
|PS 2.0 OR|0293800000|A.33|PZ ZH 16|9013600000|J.35|Q 2 AKZ4|0336400000|B.58|Q 3 SAK2.5|0337100000|C.2|
|PS 2.3 RT|0180400000|E.3||||Q 2 AKZ4|0336400000|B.59|Q 3 SAK2.5|0337100000|B.39|
|PS 2.3 RT<br>PS 2.3 RT|0180400000<br>0180400000|A.2<br>E.9|**Q**|||Q 2 AKZ4<br>Q 2 AKZ4SS|0336400000<br>0369000000|A.54<br>I.11|Q 3 SAK2.5<br>Q 3 SAK2.5|0337100000<br>0337100000|B.45<br>A.7|
|PS 2.3 RT|0180400000|E.8|Q 10 AKZ1.5|0368500000|E.2|Q 2 AKZ4SS|0369000000|E.8|Q 3 SAK2.5|0337100000|B.2|
|PS 2.3 RT|0180400000|A.54|Q 10 AKZ1.5|0368500000|I.11|Q 2 DLI|1312500000|I.11|Q 3 SAK2.5|0337100000|A.40|
|PS 2.3 RT|0180400000|B.28|Q 10 AKZ1.5|0368500000|E.10|Q 2 SAK10|0457100000|A.8|Q 3 SAK4|0336800000|A.3|
|PS 2.3 RT|0180400000|A.19|Q 10 AKZ4|0368600000|E.3|Q 2 SAK10|0457100000|B.7|Q 3 SAK4|0336800000|A.37|
|PS 2.3 RT|0180400000|I.14|Q 10 AKZ4|0368600000|E.9|Q 2 SAK10|0457100000|B.3|Q 3 SAK4|0336800000|B.36|
|PS 2.3 RT|0180400000|A.50|Q 10 AKZ4|0368600000|B.38|Q 2 SAK10|0457100000|C.3|Q 3 SAK4|0336800000|C.4|
|PS 2.3 RT|0180400000|A.51|Q 10 AKZ4|0368600000|E.12|Q 2 SAK10|0457100000|A.3|Q 3 SAK4|0336800000|I.9|
|PS 2.3 RT|0180400000|A.52|Q 10 AKZ4|0368600000|A.56|Q 2 SAK10|0457100000|I.9|Q 3 SAK4|0336800000|B.6|
|PS 2.3 RT|0180400000|A.53|Q 10 AKZ4|0368600000|E.11|Q 2 SAK16|0457500000|B.4|Q 3 SAK4|0336800000|C.5|
|PS 2.3 RT|0180400000|A.11|Q 10 AKZ4|0368600000|E.13|Q 2 SAK16|0457500000|C.3|Q 3 SAK4|0336800000|D.6|
|PS 2.3 RT|0180400000|B.40|Q 10 AKZ4|0368600000|A.13|Q 2 SAK16|0457500000|A.9|Q 3 SAK4|0336800000|A.7|
|PS 2.3 RT|0180400000|A.55|Q 10 AKZ4|0368600000|B.37|Q 2 SAK16|0457500000|A.4|Q 3 SAK4|0336800000|B.42|
|PS 2.3 RT|0180400000|A.56|Q 10 AKZ4|0368600000|A.38|Q 2 SAK16|0457500000|B.7|Q 3 SAK4|0336800000|B.43|
|PS 2.3 RT|0180400000|B.45|Q 10 AKZ4|0368600000|B.11|Q 2 SAK16|0457500000|I.9|Q 3 SAK4|0336800000|B.3|
|PS 2.3 RT|0180400000|B.43|Q 10 AKZ4|0368600000|A.39|Q 2 SAK2.5|0337000000|B.39|Q 3 SAK4|0336800000|A.36|
|PS 2.3 RT|0180400000|B.42|Q 10 AKZ4|0368600000|A.52|Q 2 SAK2.5|0337000000|A.40|Q 3 SAK4|0336800000|C.2|
|PS 2.3 RT|0180400000|B.41|Q 10 AKZ4|0368600000|B.10|Q 2 SAK2.5|0337000000|B.38|Q 3 SAK6N|0456800000|B.3|
|PS 2.3 RT|0180400000|A.18|Q 10 AKZ4|0368600000|A.12|Q 2 SAK2.5|0337000000|A.2|Q 3 SAK6N|0456800000|I.9|
|PS 2.3 RT|0180400000|A.38|Q 10 AKZ4|0368600000|E.10|Q 2 SAK2.5|0337000000|A.7|Q 3 SAK6N|0456800000|A.3|
|PS 2.3 RT|0180400000|B.19|Q 10 AKZ4SS|0369300000|E.8|Q 2 SAK2.5|0337000000|B.2|Q 3 SAK6N|0456800000|A.8|
|PS 2.3 RT|0180400000|B.56|Q 10 AKZ4SS|0369300000|I.11|Q 2 SAK2.5|0337000000|B.6|Q 3 SAK6N|0456800000|B.7|
|PS 2.3 RT|0180400000|A.13|Q 10 DLI|1313100000|I.11|Q 2 SAK2.5|0337000000|B.45|Q 3 SAK6N|0456800000|I.21|
|PS 2.3 RT|0180400000|B.57|Q 10 SAK10|0457400000|I.9|Q 2 SAK2.5|0337000000|C.2|Q 3 SAK6N|0456800000|C.3|
|PS 2.3 RT|0180400000|E.2|Q 10 SAK10|0457400000|C.3|Q 2 SAK4|0336700000|C.2|Q 3 SAKD2.5N|0367900000|B.2|
|PS 2.3 RT|0180400000|B.2|Q 10 SAK10|0457400000|A.3|Q 2 SAK4|0336700000|C.4|Q 3 SAKD2.5N|0367900000|A.2|
**X.8**
|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|Q 4 AKZ1.5|0368400000|E.10|QB 2 WI RA6 IS|0482700000|A.50|QL 10 SAKS1|0338800000|A.24|QL 2 SAKS4|0328000000|I.9|
|Q 4 AKZ1.5|0368400000|I.11|QB 2 WI RA8 IS|0461100000|E.6|QL 10 SAKS2|0338900000|A.26|QL 2 SAKS4|0328000000|B.24|
|Q 4 AKZ1.5|0368400000|E.2|QB 2 WI RA8 IS|0461100000|C.7|QL 10 SAKS2|0338900000|A.27|QL 2 SAKS4|0328000000|A.27|
|Q 4 AKZ4|0336600000|B.58|QB 2 WI RA8 IS|0461100000|B.21|QL 10 SAKS2|0338900000|I.9|QL 2 SAKS4|0328000000|A.26|
|Q 4 AKZ4|0336600000|A.55|QB 3 SAKT1|0205800000|I.21|QL 10 SAKS2|0338900000|B.25|QL 3 DLI|0297300000|I.9|
|Q 4 AKZ4|0336600000|A.54|QB 3 WI RA6 IS|0482800000|A.19|QL 10 SAKS2|0338900000|B.24|QL 3 RSF1+2|0267500000|B.28|
|Q 4 AKZ4|0336600000|A.12|QB 3 WI RA6 IS|0482800000|B.57|QL 10 SAKS4|0339000000|A.27|QL 3 RSF1+2|0267500000|B.29|
|Q 4 AKZ4|0336600000|B.61|QB 3 WI RA6 IS|0482800000|B.61|QL 10 SAKS4|0339000000|I.9|QL 3 SAK10|0470400000|I.9|
|Q 4 AKZ4<br>Q 4 AKZ4<br>Q 4 AKZ4<br>Q 4 AKZ4|0336600000<br>0336600000<br>0336600000<br>0336600000|A.53<br>A.39<br>B.59<br>B.60|QB 3 WI RA6 IS<br>QB 3 WI RA6 IS<br>QB 3 WI RA6 IS<br>QB 3 WI RA6 IS|0482800000<br>0482800000<br>0482800000<br>0482800000|B.39<br>B.60<br>B.56<br>B.16|QL 10 SAKS4<br>QL 10 SAKS4<br>QL 10 SAKS4<br>QL 15 SAK6N|0339000000<br>0339000000<br>0339000000<br>0221200000|B.24<br>B.25<br>A.26<br>I.21|QL 3 SAK16<br>QL 3 SAK2.5<br>QL 3 SAK2.5<br>QL 3 SAK2.5|0470800000<br>0156000000<br>0156000000<br>0156000000|I.9<br>B.32<br>I.10<br>I.9|
|Q 4 AKZ4|0336600000|A.56|QB 3 WI RA6 IS|0482800000|B.38|QL 2 DLI|0297200000|I.9|QL 3 SAK2.5|0156000000|A.33|
|Q 4 AKZ4|0336600000|B.57|QB 3 WI RA6 IS|0482800000|B.17|QL 2 KST10|9501370000|B.55|QL 3 SAK35|0123700000|C.4|
|Q 4 AKZ4|0336600000|E.3|QB 3 WI RA6 IS|0482800000|A.55|QL 2 KST10|9501370000|A.49|QL 3 SAK35|0123700000|B.8|
|Q 4 AKZ4|0336600000|A.50|QB 3 WI RA6 IS|0482800000|A.20|QL 2 KST12|9501380000|A.49|QL 3 SAK35|0123700000|B.4|
|Q 4 AKZ4|0336600000|A.38|QB 3 WI RA6 IS|0482800000|B.40|QL 2 KST12|9501380000|B.55|QL 3 SAK35|0123700000|A.4|
|Q 4 AKZ4|0336600000|A.51|QB 3 WI RA6 IS|0482800000|B.59|QL 2 KST6|9501350000|B.54|QL 3 SAK35|0123700000|A.5|
|Q 4 AKZ4|0336600000|E.9|QB 3 WI RA6 IS|0482800000|A.50|QL 2 KST6|9501350000|A.48|QL 3 SAK35|0123700000|I.9|
|Q 4 AKZ4|0336600000|B.11|QB 3 WI RA6 IS|0482800000|A.18|QL 2 KST8|9501360000|B.55|QL 3 SAK35|0123700000|B.5|
|Q 4 AKZ4|0336600000|I.11|QB 3 WI RA6 IS|0482800000|A.56|QL 2 KST8|9501360000|A.49|QL 3 SAK35N|0565000000|B.9|
|Q 4 AKZ4|0336600000|A.52|QB 3 WI RA6 IS|0482800000|B.58|QL 2 RSF1+2|0267400000|B.29|QL 3 SAK35N|0565000000|A.5|
|Q 4 AKZ4|0336600000|A.13|QB 3 WI RA6 IS|0482800000|A.54|QL 2 RSF1+2|0267400000|B.28|QL 3 SAK35N|0565000000|I.9|
|Q 4 AKZ4|0336600000|B.37|QB 3 WI RA6 IS|0482800000|A.53|QL 2 SAK10|0470300000|I.10|QL 3 SAK35N|0565000000|B.5|
|Q 4 AKZ4|0336600000|E.12|QB 3 WI RA6 IS|0482800000|A.52|QL 2 SAK10|0470300000|I.9|QL 3 SAK35N|0565000000|A.9|
|Q 4 AKZ4|0336600000|B.10|QB 3 WI RA6 IS|0482800000|A.51|QL 2 SAK16|0470700000|I.9|QL 3 SAK4|0130700000|A.37|
|Q 4 AKZ4|0336600000|B.38|QB 3 WI RA8 IS|0461200000|E.6|QL 2 SAK2.5|0155900000|A.33|QL 3 SAK4|0130700000|I.9|
|Q 4 AKZ4|0336600000|E.13|QB 3 WI RA8 IS|0461200000|C.7|QL 2 SAK2.5|0155900000|I.9|QL 3 SAK4|0130700000|A.38|
|Q 4 AKZ4|0336600000|E.11|QB 3 WI RA8 IS|0461200000|B.21|QL 2 SAK2.5|0155900000|B.32|QL 3 SAK4|0130700000|B.44|
|Q 4 AKZ4|0336600000|E.10|QB 4 SAKT1|0205900000|I.21|QL 2 SAK2.5|0155900000|I.10|QL 3 SAK4|0130700000|B.37|
|Q 4 AKZ4|0336600000|B.56|QB 4 WI RA6 IS|0482900000|A.53|QL 2 SAK35|0123600000|B.8|QL 3 SAK6N|0194400000|I.10|
|Q 4 AKZ4SS|0369200000|I.11|QB 4 WI RA6 IS|0482900000|B.56|QL 2 SAK35|0123600000|I.9|QL 3 SAK6N|0194400000|B.28|
|Q 4 AKZ4SS|0369200000|E.8|QB 4 WI RA6 IS|0482900000|A.54|QL 2 SAK35|0123600000|C.4|QL 3 SAK6N|0194400000|A.32|
|Q 4 DLI|1312700000|I.11|QB 4 WI RA6 IS|0482900000|B.61|QL 2 SAK35|0123600000|B.5|QL 3 SAK6N|0194400000|I.21|
|Q 4 SAK10|0457300000|C.3|QB 4 WI RA6 IS|0482900000|B.58|QL 2 SAK35|0123600000|B.4|QL 3 SAK6N|0194400000|A.33|
|Q 4 SAK10|0457300000|B.7|QB 4 WI RA6 IS|0482900000|A.55|QL 2 SAK35|0123600000|A.4|QL 3 SAK6N|0194400000|B.32|
|Q 4 SAK10|0457300000|A.3|QB 4 WI RA6 IS|0482900000|B.59|QL 2 SAK35|0123600000|A.5|QL 3 SAK6N|0194400000|A.11|
|Q 4 SAK10|0457300000|I.9|QB 4 WI RA6 IS|0482900000|B.57|QL 2 SAK35N|0564900000|I.9|QL 3 SAK6N|0194400000|I.9|
|Q 4 SAK10|0457300000|B.3|QB 4 WI RA6 IS|0482900000|A.52|QL 2 SAK35N|0564900000|A.9|QL 3 SAK6N|0194400000|B.31|
|Q 4 SAK10|0457300000|A.8|QB 4 WI RA6 IS|0482900000|B.60|QL 2 SAK35N|0564900000|B.5|QL 3 SAK70|0167000000|I.9|
|Q 4 SAK16|0457700000|B.4|QB 4 WI RA6 IS|0482900000|A.50|QL 2 SAK35N|0564900000|B.9|QL 3 SAK70|0167000000|B.9|
|Q 4 SAK16|0457700000|I.9|QB 4 WI RA6 IS|0482900000|B.16|QL 2 SAK35N|0564900000|A.5|QL 3 SAK70|0167000000|A.6|
|Q 4 SAK16|0457700000|A.4|QB 4 WI RA6 IS|0482900000|B.40|QL 2 SAK4|0130600000|A.38|QL 3 SAKA10|0135600000|B.19|
|Q 4 SAK16|0457700000|C.3|QB 4 WI RA6 IS|0482900000|A.18|QL 2 SAK4|0130600000|B.44|QL 3 SAKA10|0135600000|A.20|
|Q 4 SAK16|0457700000|A.9|QB 4 WI RA6 IS|0482900000|A.51|QL 2 SAK4|0130600000|B.37|QL 3 SAKA10|0135600000|B.30|
|Q 4 SAK16|0457700000|B.7|QB 4 WI RA6 IS|0482900000|B.39|QL 2 SAK4|0130600000|A.37|QL 3 SAKB10|0114300000|B.30|
|Q 4 SAK2.5|0337200000|A.40|QB 4 WI RA6 IS|0482900000|B.38|QL 2 SAK4|0130600000|I.10|QL 3 SAKG28|0407600000|B.46|
|Q 4 SAK2.5|0337200000|A.2|QB 4 WI RA6 IS|0482900000|A.19|QL 2 SAK4|0130600000|I.9|QL 3 SAKG28|0407600000|I.9|
|Q 4 SAK2.5|0337200000|B.6|QB 4 WI RA6 IS|0482900000|B.17|QL 2 SAK6N|0194300000|A.32|QL 3 SAKG28|0407600000|B.47|
|Q 4 SAK2.5|0337200000|B.45|QB 4 WI RA6 IS|0482900000|A.56|QL 2 SAK6N|0194300000|I.9|QL 3 SAKG28|0407600000|A.10|
|Q 4 SAK2.5|0337200000|A.7|QB 4 WI RA6 IS|0482900000|A.20|QL 2 SAK6N|0194300000|I.10|QL 3 SAKG28|0407600000|B.9|
|Q 4 SAK2.5|0337200000|B.39|QB 4 WI RA8 IS|0461300000|E.6|QL 2 SAK6N|0194300000|A.11|QL 3 SAKG32+70|0441500000|A.43|
|Q 4 SAK2.5|0337200000|B.38|QB 4 WI RA8 IS|0461300000|C.7|QL 2 SAK6N|0194300000|A.33|QL 3 SAKG32+70|0441500000|A.42|
|Q 4 SAK2.5|0337200000|B.2|QB 4 WI RA8 IS|0461300000|B.21|QL 2 SAK6N|0194300000|B.32|QL 3 SAKG32+70|0441500000|A.44|
|Q 4 SAK2.5|0337200000|C.2|QL 10 RSF1+2|0341700000|B.29|QL 2 SAK6N|0194300000|B.28|QL 3 SAKG32+70|0441500000|B.48|
|Q 4 SAK4|0336900000|A.37|QL 10 RSF1+2|0341700000|B.28|QL 2 SAK6N|0194300000|I.21|QL 3 SAKG32+70|0441500000|B.49|
|Q 4 SAK4|0336900000|B.3|QL 10 SAK10|0470600000|I.9|QL 2 SAK6N|0194300000|B.31|QL 3 SAKG32+70|0441500000|B.50|
|Q 4 SAK4|0336900000|A.36|QL 10 SAK16|0471000000|I.9|QL 2 SAK6N-SAK35|0207400000|I.10|QL 3 SAKG40|0263500000|B.50|
|Q 4 SAK4|0336900000|C.4|QL 10 SAK2.5|0338100000|I.9|QL 2 SAK70|0345300000|A.6|QL 3 SAKG40|0263500000|B.51|
|Q 4 SAK4|0336900000|B.43|QL 10 SAK2.5|0338100000|A.33|QL 2 SAK70|0345300000|B.9|QL 3 SAKG40/35|0444900000|A.45|
|Q 4 SAK4|0336900000|C.2|QL 10 SAK2.5|0338100000|B.32|QL 2 SAK70|0345300000|I.9|QL 3 SAKG46|0444400000|A.46|
|Q 4 SAK4|0336900000|C.5|QL 10 SAK2.5|0338100000|I.10|QL 2 SAKA10|0135500000|I.10|QL 3 SAKG46|0444400000|B.52|
|Q 4 SAK4|0336900000|B.36|QL 10 SAK35|0338600000|C.4|QL 2 SAKA10|0135500000|B.19|QL 3 SAKG46|0444400000|A.47|
|Q 4 SAK4|0336900000|I.9|QL 10 SAK35|0338600000|B.8|QL 2 SAKA10|0135500000|A.20|QL 3 SAKG54|0408000000|B.53|
|Q 4 SAK4|0336900000|B.42|QL 10 SAK35|0338600000|A.5|QL 2 SAKA10|0135500000|B.30|QL 3 SAKG54|0408000000|A.47|
|Q 4 SAK4|0336900000|B.6|QL 10 SAK35|0338600000|A.4|QL 2 SAKB10|0114100000|B.30|QL 3 SAKK 10|9502660000|D.3|
|Q 4 SAK4|0336900000|A.7|QL 10 SAK35|0338600000|I.11|QL 2 SAKG28|0551200000|I.9|QL 3 SAKK 10 TIN|9509480000|D.3|
|Q 4 SAK4|0336900000|D.6|QL 10 SAK35|0338600000|I.9|QL 2 SAKG28|0551200000|A.10|QL 3 SAKK 4|9502550000|D.2|
|Q 4 SAK4|0336900000|A.3|QL 10 SAK35|0338600000|B.4|QL 2 SAKG28|0551200000|B.47|QL 3 SAKK 4 TIN|9509430000|D.2|
|Q 4 SAK6N|0456900000|A.8|QL 10 SAK35|0338600000|B.5|QL 2 SAKG28|0551200000|B.9|QL 3 SAKS1|0191500000|A.24|
|Q 4 SAK6N|0456900000|I.21|QL 10 SAK35N|0565200000|B.9|QL 2 SAKG28|0551200000|B.46|QL 3 SAKS1|0191500000|B.22|
|Q 4 SAK6N|0456900000|A.3|QL 10 SAK35N|0565200000|A.5|QL 2 SAKG32+70|0194000000|A.44|QL 3 SAKS1|0191500000|I.9|
|Q 4 SAK6N|0456900000|B.3|QL 10 SAK35N|0565200000|B.5|QL 2 SAKG32+70|0194000000|B.48|QL 3 SAKS1|0191500000|B.23|
|Q 4 SAK6N|0456900000|B.7|QL 10 SAK35N|0565200000|A.9|QL 2 SAKG32+70|0194000000|B.49|QL 3 SAKS1|0191500000|A.25|
|Q 4 SAK6N|0456900000|C.3|QL 10 SAK35N|0565200000|I.9|QL 2 SAKG32+70|0194000000|B.50|QL 3 SAKS2|0207900000|A.26|
|Q 4 SAK6N|0456900000|I.9|QL 10 SAK4|0338200000|B.37|QL 2 SAKG32+70|0194000000|A.43|QL 3 SAKS2|0207900000|B.24|
|Q 4 SAKD2.5N|0368000000|A.2|QL 10 SAK4|0338200000|A.38|QL 2 SAKG32+70|0194000000|A.42|QL 3 SAKS2|0207900000|A.27|
|Q 4 SAKD2.5N|0368000000|B.2|QL 10 SAK4|0338200000|A.37|QL 2 SAKG40|0194100000|B.50|QL 3 SAKS2|0207900000|B.25|
|QB 10 SAKT1|0343800000|I.21|QL 10 SAK4|0338200000|I.10|QL 2 SAKG40|0194100000|B.51|QL 3 SAKS2|0207900000|I.9|
|QB 2 SAKT1|0205700000|I.21|QL 10 SAK4|0338200000|I.9|QL 2 SAKG40/35|0211400000|A.45|QL 3 SAKS4|0328100000|B.25|
|QB 2 WI RA6 IS|0482700000|B.40|QL 10 SAK4|0338200000|B.44|QL 2 SAKG46|0247000000|A.47|QL 3 SAKS4|0328100000|B.24|
|QB 2 WI RA6 IS|0482700000|B.57|QL 10 SAK6N|0338300000|B.31|QL 2 SAKG46|0247000000|B.52|QL 3 SAKS4|0328100000|I.9|
|QB 2 WI RA6 IS|0482700000|B.58|QL 10 SAK6N|0338300000|A.11|QL 2 SAKG46|0247000000|A.46|QL 3 SAKS4|0328100000|A.27|
|QB 2 WI RA6 IS|0482700000|A.20|QL 10 SAK6N|0338300000|I.9|QL 2 SAKG54|0264400000|A.47|QL 3 SAKS4|0328100000|A.26|
|QB 2 WI RA6 IS|0482700000|A.53|QL 10 SAK6N|0338300000|I.10|QL 2 SAKG54|0264400000|B.53|QL 4 RSF1+2|0267600000|B.29|
|QB 2 WI RA6 IS|0482700000|B.60|QL 10 SAK6N|0338300000|I.21|QL 2 SAKK 10|9502650000|D.3|QL 4 RSF1+2|0267600000|B.28|
|QB 2 WI RA6 IS|0482700000|A.54|QL 10 SAK6N|0338300000|B.28|QL 2 SAKK 10 TIN|9509470000|D.3|QL 4 SAK10|0470500000|I.9|
|QB 2 WI RA6 IS|0482700000|B.61|QL 10 SAK6N|0338300000|B.32|QL 2 SAKK 4|9502540000|D.2|QL 4 SAK16|0470900000|I.9|
|QB 2 WI RA6 IS|0482700000|A.51|QL 10 SAK6N|0338300000|A.32|QL 2 SAKK 4 TIN|9509420000|D.2|QL 4 SAK2.5|0156100000|I.9|
|QB 2 WI RA6 IS|0482700000|B.16|QL 10 SAK6N|0338300000|A.33|QL 2 SAKS1|0191400000|A.24|QL 4 SAK2.5|0156100000|A.33|
|QB 2 WI RA6 IS|0482700000|B.39|QL 10 SAKA10|0338500000|B.19|QL 2 SAKS1|0191400000|I.9|QL 4 SAK2.5|0156100000|B.32|
|QB 2 WI RA6 IS|0482700000|B.38|QL 10 SAKA10|0338500000|B.30|QL 2 SAKS1|0191400000|A.25|QL 4 SAK2.5|0156100000|I.10|
|QB 2 WI RA6 IS|0482700000|B.56|QL 10 SAKB10|0338400000|B.30|QL 2 SAKS1|0191400000|B.23|QL 4 SAK35|0123800000|A.4|
|QB 2 WI RA6 IS|0482700000|A.56|QL 10 SAKK 10|9502680000|D.3|QL 2 SAKS1|0191400000|B.22|QL 4 SAK35|0123800000|I.9|
|QB 2 WI RA6 IS|0482700000|B.59|QL 10 SAKK 10 TIN|9509500000|D.3|QL 2 SAKS2|0207800000|A.26|QL 4 SAK35|0123800000|C.4|
|QB 2 WI RA6 IS|0482700000|A.52|QL 10 SAKK 4|9502570000|D.2|QL 2 SAKS2|0207800000|I.9|QL 4 SAK35|0123800000|B.5|
|QB 2 WI RA6 IS|0482700000|A.55|QL 10 SAKK 4 TIN|9509450000|D.2|QL 2 SAKS2|0207800000|B.25|QL 4 SAK35|0123800000|B.4|
|QB 2 WI RA6 IS|0482700000|A.19|QL 10 SAKS1|0338800000|I.9|QL 2 SAKS2|0207800000|A.27|QL 4 SAK35|0123800000|B.8|
|QB 2 WI RA6 IS|0482700000|B.17|QL 10 SAKS1|0338800000|B.23|QL 2 SAKS2|0207800000|B.24|QL 4 SAK35|0123800000|A.5|
|QB 2 WI RA6 IS|0482700000|A.18|QL 10 SAKS1|0338800000|A.25|QL 2 SAKS4|0328000000|B.25|QL 4 SAK35N|0565100000|B.5|
**X**
**X.9**
**X**
|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|QL 4 SAK35N|0565100000|B.9|RSF 2|0623320000|B.29|SAK 4 CUN/EP/SW|0168800000|D.6|SAKG 46/35 II|0637920000|A.46|
|QL 4 SAK35N|0565100000|A.9|RSF 3 PA|0497560000|B.28|SAK 4 EP/SW|0128300000|I.7|SAKG 46/35 II/GW|0638020000|A.47|
|QL 4 SAK35N|0565100000|A.5|RSF 3/35|9501160000|A.11|SAK 4 EP/SW|0128300000|D.6|SAKG 54 II|0170720000|B.53|
|QL 4 SAK35N|0565100000|I.9||||SAK 4 KRG|0128320000|B.6|SAKG 54 II/GW|0185420000|B.53|
|QL 4 SAK4<br>QL 4 SAK4|0130800000<br>0130800000|B.44<br>B.37|**S**|||SAK 4 KRG BL<br>SAK 4 KRG BL|0128370000<br>0128370000|I.7<br>B.6|SAKG 54/35 II<br>SAKG 54/35 II/GW|0638120000<br>0638220000|A.47<br>A.47|
|QL 4 SAK4|0130800000|A.38|SAK 10|0110060000|B.3|SAK 4 OR|0105060000|I.7|SAKG 70 II/GW|0150420000|B.50|
|QL 4 SAK4|0130800000|A.37|SAK 10 BL|0110080000|B.3|SAK 4 S 6.3/2.8|0401260000|B.37|SAKG 70/35 II/GW|0636620000|A.44|
|QL 4 SAK4<br>QL 4 SAK4<br>QL 4 SAK6N<br>QL 4 SAK6N|0130800000<br>0130800000<br>0194500000<br>0194500000|I.10<br>I.9<br>A.11<br>I.9|SAK 10 BL<br>SAK 10 KRG<br>SAK 10 KRG/BL<br>SAK 10 KRG/BL|0110080000<br>0110020000<br>0110070000<br>0110070000|I.7<br>B.7<br>I.7<br>B.7|SAK 4 S 6.3/2.8/KRG<br>SAK 4 S/35 6.3/2.8<br>SAK 4 SS 6.3/2.8<br>SAK 4 SS 6.3/2.8 KRG|0401220000<br>0630360000<br>0479660000<br>0479620000|B.44<br>A.37<br>B.37<br>B.44|SAKH 10 CUN/EP/SW<br>SAKH 10 EP/SW<br>SAKH 10 EP/SW<br>SAKH 35 EP/SW|1104700000<br>0126700000<br>0126700000<br>1596240000|D.7<br>I.7<br>D.7<br>D.7|
|QL 4 SAK6N|0194500000|A.33|SAK 10 OR|0110040000|I.7|SAK 4 SS 6.3/KRG|0352920000|B.44|SAKH 35 EP/SW|1596240000|I.7|
|QL 4 SAK6N|0194500000|B.28|SAK 10/35|0443760000|A.3|SAK 4 SS/35 6.3 GR|0646930000|I.7|SAKH 6 EP/SW|0126600000|I.7|
|QL 4 SAK6N|0194500000|B.32|SAK 10/35 BL|0443780000|A.3|SAK 4 SS/35 6.3/2.8|0630460000|A.38|SAKH 6 EP/SW|0126600000|D.6|
|QL 4 SAK6N|0194500000|I.21|SAK 10/35 BL|0443780000|I.7|SAK 4/35|0443660000|A.3|SAKK 10|9502610000|D.3|
|QL 4 SAK6N|0194500000|B.31|SAK 10/35 KRG|0443720000|A.8|SAK 4/35 BL|0443680000|A.3|SAKK 10 KER/WS|1598090000|D.3|
|QL 4 SAK6N|0194500000|A.32|SAK 10/35 KRG/BL|0443770000|A.8|SAK 4/35 BL|0443680000|I.7|SAKK 4|9502600000|D.2|
|QL 4 SAK6N|0194500000|I.10|SAK 10/35 KRG/BL|0443770000|I.7|SAK 4/35 KRG|0443620000|A.7|SAKK 4 KER/WS|1598080000|D.2|
|QL 4 SAKA10|0135700000|B.30|SAK 10/EN|0337660000|C.3|SAK 4/35 KRG/BL|0443670000|A.7|SAKR|0412160000|B.16|
|QL 4 SAKA10|0135700000|B.19|SAK 10/EN BL|1784410000|C.3|SAK 4/35 KRG/BL|0443670000|I.7|SAKR 15|0412760000|E.3|
|QL 4 SAKA10|0135700000|A.20|SAK 10/EN BL|1784410000|I.7|SAK 4/35 OR|1323660000|I.7|SAKR 15 2STB|0412860000|E.3|
|QL 4 SAKB10|0114500000|B.30|SAK 10/EN GR RAL 7042|1853960000|I.7|SAK 4/35/AP GG|0443650000|I.7|SAKR 2STB|0412260000|B.16|
|QL 4 SAKG28|0407700000|B.47|SAK 10/EN OR|1772830000|I.7|SAK 4/EN|0467460000|C.2|SAKR 2STB BL|0412280000|B.16|
|QL 4 SAKG28|0407700000|I.9|SAK 10/EN SW|1773900000|I.7|SAK 4/EN BL|0467480000|I.7|SAKR 2STB BL|0412280000|I.7|
|QL 4 SAKG28|0407700000|A.10|SAK 16|0271060000|B.4|SAK 4/EN BL|0467480000|C.2|SAKR 2STB KRG|0412220000|B.18|
|QL 4 SAKG28|0407700000|B.46|SAK 16 BL|0271080000|I.7|SAK 4/EN BR|9130990000|I.7|SAKR BL|0412180000|I.7|
|QL 4 SAKG28|0407700000|B.9|SAK 16 BL|0271080000|B.4|SAK 4/EN GE|9129930000|I.7|SAKR BL|0412180000|B.16|
|QL 4 SAKG32+70|0441600000|B.49|SAK 16 KRG|0271020000|B.7|SAK 4/EN GN|9129950000|I.7|SAKR KRG|0412120000|B.18|
|QL 4 SAKG32+70|0441600000|A.43|SAK 16/35 KRG|0380620000|A.9|SAK 4/EN GR|9129960000|I.7|SAKR LL|0464460000|B.40|
|QL 4 SAKG32+70|0441600000|A.42|SAK 16/35 PA|0380660000|A.4|SAK 4/EN GR 7042|1853950000|I.7|SAKR LL 2STB|0294260000|B.41|
|QL 4 SAKG32+70|0441600000|A.44|SAK 16/35 PA/BL|0380680000|I.7|SAK 4/EN OR|0467400000|I.7|SAKR LS 2STB|0518160000|B.40|
|QL 4 SAKG32+70|0441600000|B.48|SAK 16/35 PA/BL|0380680000|A.4|SAK 4/EN RT|9129920000|I.7|SAKR OR|1461960000|I.7|
|QL 4 SAKG32+70|0441600000|B.50|SAK 16/EN|0339760000|C.3|SAK 4/EN SW|9130980000|I.7|SAKR TS SE 1.6|0469360000|B.39|
|QL 4 SAKG40|0409800000|B.50|SAK 16/EN BL|1784390000|I.7|SAK 4/EN WS|1773340000|I.7|SAKR/35|0172160000|A.18|
|QL 4 SAKG40|0409800000|B.51|SAK 16/EN BL|1784390000|C.3|SAK 6/35 GN/GE|1866850000|I.7|SAKR/35 2STB BL|0183380000|I.7|
|QL 4 SAKG40/35|0445000000|A.45|SAK 2.5|0279660000|B.2|SAK 6/35 KRG|0380520000|A.8|SAKR/35 BL|0172180000|I.7|
|QL 4 SAKG46|0444500000|A.46|SAK 2.5 AL BLUE (E)|6253140000|I.7|SAK 6/35 KRG/BL|0380570000|A.8|SAKR/35 BL|0172180000|A.18|
|QL 4 SAKG46|0444500000|B.52|SAK 2.5 BL|0279680000|I.7|SAK 6/35 KRG/BL|0380570000|I.7|SAKR/35 WS|0172190000|I.7|
|QL 4 SAKG46|0444500000|A.47|SAK 2.5 BL|0279680000|B.2|SAK 6/35 PA|0380560000|A.3|SAKRD/35|0185760000|A.18|
|QL 4 SAKG54|0247400000|B.53|SAK 2.5 BL RS-SET|1817860000|I.7|SAK 6/35 PA/BL|0380580000|I.7|SAKS 1/32 G20 GL 115VAC|0385320000|B.22|
|QL 4 SAKG54|0247400000|A.47|SAK 2.5 KRG|0279620000|B.6|SAK 6/35 PA/BL|0380580000|A.3|SAKS 1/32 G20 GL 230VAC|0306120000|B.22|
|QL 4 SAKK 10|9502670000|D.3|SAK 2.5 KRG/BL|0279670000|I.7|SAK 6/EN|0212860000|C.3|SAKS 1/32 G20 LD 24VDC|0371420000|B.22|
|QL 4 SAKK 10 TIN|9509490000|D.3|SAK 2.5 KRG/BL|0279670000|B.6|SAK 6/EN BL|0212880000|I.7|SAKS 1/32 G25 GL 230VAC|0309320000|B.23|
|QL 4 SAKK 4|9502560000|D.2|SAK 2.5 LS KRG|0544120000|B.45|SAK 6/EN BL|0212880000|C.3|SAKS 1/35 G20 GL 115VAC|8068330000|A.24|
|QL 4 SAKK 4 TIN|9509440000|D.2|SAK 2.5 OR|1326360000|I.7|SAK 6/EN GE|1772820000|I.7|SAKS 1/35 G20 GL 230VAC|0199920000|A.24|
|QL 4 SAKS1|0191600000|A.25|SAK 2.5 SL|0351460000|B.39|SAK 6/EN OR|1772810000|I.7|SAKS 1/35 G20 LD 24VAC|1111320000|A.24|
|QL 4 SAKS1|0191600000|A.24|SAK 2.5 SW 1X1|0108560000|I.7|SAK 6/EN RT|0212840000|I.7|SAKS 1/35 G20 LD 24VDC|0225820000|A.24|
|QL 4 SAKS1|0191600000|B.23|SAK 2.5 SW 1X1|0108560000|B.38|SAK 6/EN SW|0212810000|I.7|SAKS 1/35 G20 LD 48VAC|0214020000|A.24|
|QL 4 SAKS1|0191600000|I.9|SAK 2.5 SW 1X1/KRG|0108520000|I.7|SAK 6/EN WS|1773350000|I.7|SAKS 1/35 G25 GL 230VAC|0198620000|A.25|
|QL 4 SAKS1|0191600000|B.22|SAK 2.5/35|0380460000|A.2|SAK 6N|0193260000|B.3|SAKS 1/35/G20|0501620000|A.24|
|QL 4 SAKS2|0208000000|A.27|SAK 2.5/35 BL|0380480000|A.2|SAK 6N BL|0193280000|I.7|SAKS 1/35/G25|0501520000|A.25|
|QL 4 SAKS2|0208000000|A.26|SAK 2.5/35 BL|0380480000|I.7|SAK 6N BL|0193280000|B.3|SAKS 1/G20|0191220000|B.22|
|QL 4 SAKS2|0208000000|I.9|SAK 2.5/35 DBL|1799920000|I.7|SAK 6N KRG|0193220000|B.7|SAKS 1/G25|0191120000|B.23|
|QL 4 SAKS2|0208000000|B.24|SAK 2.5/35 GE|1821480000|I.7|SAK 70 KRG|0340820000|B.9|SAKS 2|0206820000|B.24|
|QL 4 SAKS2|0208000000|B.25|SAK 2.5/35 KRG|0380420000|A.7|SAK 70 KRG/BL|0340870000|B.9|SAKS 2/35|1368720000|A.26|
|QL 4 SAKS4|0328200000|I.9|SAK 2.5/35 KRG/BL|0380470000|A.7|SAK 70 KRG/BL|0340870000|I.7|SAKS 3 G/5X30 500V|0297520000|B.23|
|QL 4 SAKS4|0328200000|A.26|SAK 2.5/35 KRG/BL|0380470000|I.7|SAK 70/35|0139160000|A.6|SAKS 3 GZ/6.3X32|0248920000|B.23|
|QL 4 SAKS4|0328200000|B.25|SAK 2.5/35 LL|0567260000|A.40|SAK 95 KRG|0550520000|B.9|SAKS 3/35 G/5X30 500V|0328920000|A.25|
|QL 4 SAKS4|0328200000|B.24|SAK 2.5/35 OR|0380440000|I.7|SAK 95/35 KRG|0662220000|A.10|SAKS 3/35 GZ/6.3X32|0667520000|A.25|
|QL 4 SAKS4|0328200000|A.27|SAK 2.5/35 RT|1799910000|I.7|SAK 95/35 KRG/BL|0662270000|I.7|SAKS 4|0321320000|B.24|
|QL 5 SAK6N|0220500000|I.21|SAK 2.5/35 SW|1799900000|I.7|SAKA 10|0134120000|B.30|SAKS 4 USA|0162220000|B.25|
|QL 6 SAK6N|0220600000|I.21|SAK 2.5/35 SW 1X1|0514060000|I.7|SAKA 10/EN 2GL 230VAC|8109130000|C.8|SAKS 4/35|0501820000|A.26|
|QS 2/10/4|0270860000|I.13|SAK 2.5/EN|0218660000|C.2|SAKA 10/EN 2GL 24VUC|8150150000|C.8|SAKS 4/35 USA|0178220000|A.27|
|QS 2/10/4|0270860000|<br>I.21|SAK 2.5/EN BL|0218680000|I.7|SAKB 10|0134920000|B.30|SAKS 5 380AC|0359420000|B.25|
|QS 2/12/4|0270760000|I.13|SAK 2.5/EN BL|0218680000|C.2|SAKC 10 2STB|0324120000|B.19|SAKS 5/35|0502120000|A.27|
|QS 2/12/4|0270760000|<br>I.21|SAK 2.5/EN BR|1858450000|I.7|SAKC 10/35 1STB4 KRG|1404520000|A.20|SAKT 1/35/DU1|0105820000|A.32|
|QS 2/6.5/2.3 SAK4|0212700000|I.13|SAK 2.5/EN SW|1858440000|I.7|SAKC 4 KRG|0340720000|B.19|SAKT 1/35/LT|0105420000|A.32|
|QS 2/8/4|0270960000|A.32|SAK 2.5/EN WS|1858460000|I.7|SAKC 4/2STB7 BL|0340670000|I.7|SAKT 1/35/LT STB|0105620000|A.32|
|QS 2/8/4|0270960000|A.33|SAK 2.5/TC AL|0107160000|B.34|SAKC 4/35|0357520000|A.20|SAKT 1/35/QT1|0105720000|A.33|
|QS 2/8/4|0270960000|I.13|SAK 2.5/TC AL BL|0107180000|I.7|SAKD 2.5/35|0268860000|A.2|SAKT 1/35/QT2|0124620000|A.33|
|QS 2/8/4|0270960000|B.32|SAK 2.5/TC CH|0107260000|B.34|SAKD 2.5/35 BL|0268880000|I.7|SAKT 1/DU1|0195620000|B.31|
|QS 2/8/4|0270960000|B.31|SAK 2.5/TC CH BL|0107280000|I.7|SAKD 2.5/35 BL|0268880000|A.2|SAKT 1/DU2|0550420000|B.31|
|QS 2/8/4|0270960000|I.21|SAK 2.5/TC CO|0189860000|B.34|SAKD 2.5N|0215560000|B.2|SAKT 1/LT|0269120000|B.31|
|QVS 2 SAKT1+2|0307300000|B.31|SAK 2.5/TC CU|0189960000|B.34|SAKD 2.5N BL|0215580000|B.2|SAKT 1/LT STB14/4|0437920000|B.31|
|QVS 2 SAKT1+2|0307300000|A.32|SAK 2.5/TC FE|0190060000|B.34|SAKD 2.5N BL|0215580000|I.7|SAKT 1/QT1|0269320000|B.31|
|QVS 2 SAKT1+2|0307300000|I.20|SAK 35|0303560000|B.4|SAKE 35|0144400000|B.14|SAKT 1/QT2|0494820000|B.31|
|QVS 2 SAKT1+2|0307300000|A.33|SAK 35 BL|0303580000|B.4|SAKE 70/32|0213200000|B.15|SAKT 2/35/LT 4STB|0106020000|A.33|
|QVS 2 SAKT1+2|0307300000|B.32|SAK 35 KRG|0303520000|B.8|SAKG 28 I|0170020000|B.46|SAKT 2/35/LT/STB|0105920000|A.33|
|QVS 2/4 SAKT4|1319260000|B.32|SAK 35/35|0380760000|A.4|SAKG 28 II|0170320000|B.47|SAKT 2/LT 4STB|0437720000|B.32|
|QVS 2/4 SAKT4|1319260000|A.33|SAK 35/35 BL|0380780000|A.4|SAKG 28 II/GW|0185020000|B.47|SAKT 2/LT O.STB|0445420000|B.32|
|QVS 2/S SAKT1+2|0358460000|I.20|SAK 35/35 BL|0380780000|I.7|SAKG 28 III|0170820000|B.48|SAKT 2/LT STB|0330620000|B.32|
|QVS 3 SAKT1+2|0329300000|I.20|SAK 35/35/IK|0582460000|A.5|SAKG 32 I|0286620000|B.48|SAKT 4/35/LT O.STB|1272420000|A.33|
|QVS 3 SAKT1+2|0329300000|A.33|SAK 35/EN|0339860000|C.4|SAKG 32 II|0170420000|B.49|SAKT 4/35/LT STB2.0|1272520000|A.33|
|QVS 3 SAKT1+2|0329300000|B.31|SAK 35/EN BL|1784400000|C.4|SAKG 32 II/GW|0185120000|B.49|SAKT 4/LT O.STB|0254120000|B.32|
|QVS 3 SAKT1+2|0329300000|B.32|SAK 35/EN BL|1784400000|I.7|SAKG 32 III|0286720000|B.49|SAKT 4/LT STB2.0|0310320000|B.32|
|QVS 3 SAKT1+2|0329300000|A.32|SAK 35/IK|0476560000|B.5|SAKG 32/35 I|0637120000|A.42|SAKT E/32 2LD 60VAC|0699020000|B.62|
|QVS 4 SAKT1+2|0307400000|B.32|SAK 35/IK KRG|0476520000|B.8|SAKG 32/35 II|0637320000|A.43|SAKT E/35 2GL 115VAC|0198020000|A.57|
|QVS 4 SAKT1+2|0307400000|B.31|SAK 35N|0550660000|B.5|SAKG 32/35 II/GW|0637420000|A.43|SAKT E/35 2GL 230VAC|0198120000|A.57|
|QVS 4 SAKT1+2|0307400000|A.32|SAK 35N KRG|0550620000|B.9|SAKG 32/35 III|0637220000|A.44|SAKT E/35 2LD 120VAC|0198220000|A.57|
|QVS 4 SAKT1+2|0307400000|A.33|SAK 35N/35|0608260000|A.5|SAKG 40 I|0286820000|B.50|SAKT E/35 2LD 30VAC|1166820000|A.57|
|QVS 4 SAKT1+2|0307400000|I.20|SAK 35N/35 KRG|0608220000|A.9|SAKG 40 II|0170520000|B.51|SAKT E/35 2LD 60VAC|0197920000|A.57|
|QVSK 2 SAKT1|1670360000|I.20|SAK 35N/35/IK|0608360000|A.5|SAKG 40 II/GW|0185220000|B.51|SBL/1912|0446100000|A.22|
||||SAK 35N/35/IK KRG|0608320000|A.9|SAKG 40 III|0286920000|B.51|SBL/1912|0446100000|B.20|
|**R**|||SAK 35N/35/IK KRG/BL<br>SAK 35N/IK|0608370000<br>0555760000|A.9<br>B.5|SAKG 40/35 I<br>SAKG 40/35 II|0637520000<br>0637720000|A.45<br>A.45|SBL/2111<br>SBL/2111|0446200000<br>0446200000|B.20<br>A.22|
|Reiniger 2000 25ml|1772130000|K.24|SAK 4|1716240000|B.3|SAKG 40/35 II/GW|0637820000|A.45|SBL/2489|0446300000|A.23|
|Reiniger 2000 25ml|1772130000|K.25|SAK 4 BL|0128380000|B.3|SAKG 40/35 III|0637620000|A.46|SCHT 14/6|1269060000|K.18|
|REINIGUNGSBECHER|1288300000|K.24|SAK 4 BL|0128380000|I.7|SAKG 46 II|0170620000|B.52|SCHT 5|0292460000|K.17|
|RSF 1 KRG|0270320000|B.28|SAK 4 BL RS-SET|1817780000|I.7|SAKG 46 II/GW|0185320000|B.52|SCHT 5 S|1631930000|K.17|
**X.10**
**X**
|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|SCHT 7|0517960000|K.17|SS M3 D 128-A 3|0164400000|B.28|STB 14/D6/4/M3 SAK10|0169900000|B.28|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|E.3|
|SCHT 9/4|1278460000|K.18|SS M3 D 128-A 3|0164400000|A.11|STB 14/D6/4/M3 SAK10|0169900000|I.15|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|A.39|
|SD 0,4x2,0x60|9037160000|J.15|SS M3 D 128-A 3|0164400000|I.10|STB 14/D6/4/M3 SAK10|0169900000|B.31|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|A.50|
|SD 0,4x2,5x75|9009030000|J.15|SS M4 D 128-A 4|0136400000|I.10|STB 16/D7/4/M4 SAK35|0140200000|B.5|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|A.51|
|SD 0,5x3,0x80|9008320000|J.15|SS M4 D 128-A 4|0136400000|A.20|STB 16/D7/4/M4 SAK35|0140200000|A.5|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|A.38|
|SD 0,6x3,5x100|9008330000|J.13|SS M4 D 128-A 4|0136400000|B.5|STB 16/D7/4/M4 SAK35|0140200000|I.15|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|E.11|
|SD 0,6x3,5x100|9008330000|J.15|SS M4 D 128-A 4|0136400000|A.26|STB 16/D7/4/M4 SAK35|0140200000|B.4|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|B.38|
|SD 0,6x3,5x200|9010110000|J.15|SS M4 D 128-A 4|0136400000|A.27|STB 16/D7/4/M4 SAK35|0140200000|A.9|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|B.37|
|SD 0,8x4,0x100<br>SD 0,8x4,5x125<br>SD 1,0x5,5x150<br>SD 1,2x6,5x150|9008340000<br>9009020000<br>9008350000<br>9009010000|J.15<br>J.15<br>J.15<br>J.15|SS M4 D 128-A 4<br>SS M4 D 128-A 4<br>SS M4 D 128-A 4<br>SS M4 D 128-A 4|0136400000<br>0136400000<br>0136400000<br>0136400000|C.4<br>B.9<br>B.8<br>B.4|STB 16/D7/4/M4 SAK35<br>STB 16/D7/4/M4 SAK35<br>STB 16/D7/4/M4 SAK35<br>STB 16/D7/4/M4 SAK35|0140200000<br>0140200000<br>0140200000<br>0140200000|A.4<br>C.4<br>B.9<br>B.8|STB 8.5/D4/2.3/M2.5 AKZ<br>STB 8.5/D4/2.3/M2.5 AKZ<br>STB 8.5/D4/2.3/M2.5 AKZ<br>STB 8.5/D4/2.3/M2.5 AKZ|0215700000<br>0215700000<br>0215700000<br>0215700000|A.54<br>E.12<br>A.56<br>E.2|
|SD TH10|9009180000|J.15|SS M4 D 128-A 4|0136400000|A.9|STB 16/D7/4/M4 SAK35|0140200000|B.30|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|E.8|
|SD TH15|9009170000|J.15|SS M4 D 128-A 4|0136400000|A.4|STB 16/D7/4/M5 SAK70|0385400000|A.10|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|E.13|
|SD TH20|9009160000|J.15|SS M4 D 128-A 4|0136400000|B.24|STB 16/D7/4/M5 SAK70|0385400000|I.15|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|B.61|
|SD TH25|9009150000|J.15|SS M4 D 128-A 4|0136400000|A.5|STB 16/D7/4/M5 SAK70|0385400000|B.9|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|B.56|
|SD TH30|9009140000|J.15|SS M4 D 128-A 4|0136400000|B.19|STB 16/D7/4/M5 SAK70|0385400000|A.6|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|B.57|
|SD TH8|9009190000|J.15|SS M4 D 128-A 4|0136400000|B.25|STB 17/D6/4/M4 SAKC10|0147100000|B.19|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|B.58|
|SDI 0,4x2,5x75|9008370000|J.14|SS M5 D 128-A 5|0346100000|A.10|STB 17/D6/4/M4 SAKC10|0147100000|A.20|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|A.12|
|SDI 0,5x3,0x100|9008380000|J.14|SS M5 D 128-A 5|0346100000|B.9|STB 17/D6/4/M4 SAKC10|0147100000|D.9|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|A.55|
|SDI 0,6x3,5x100|9008390000|J.14|SS M5 D 128-A 5|0346100000|A.6|STB 17/D6/4/M4 SAKC10|0147100000|B.29|STI Waterproof schwarz|0508401694|K.24|
|SDI 0,8x4,0x100|9008400000|J.14|SSCH 10X3X1000 CU/SN|0348900000|G.7|STB 17/D6/4/M4 SAKC10|0147100000|I.15|STI Waterproof schwarz|0508401694|K.25|
|SDI 0.4X2.0X60|9205690000|J.14|SSCH 10X3X1000 CU/SN|0348900000|G.6|STB 25 IH/BL|0343400000|I.15|STL 5|0448460000|C.6|
|SDI 1,0x4,5x125|9008910000|J.14|SSCH 10X3X1000 CU/SN|0348900000|G.5|STB 25 IH/BL|0343400000|I.20|STR 15 F. ZGB 15|1636520000|K.19|
|SDI 1,0x5,5x125|9008410000|J.14|SSCH 10X3X1000 CU/SN|0348900000|G.4|STB 25 IH/GE|0267200000|I.20|STR 5 F.SCHT 5|0294000000|K.17|
|SDI 1,6x8,0x175|9008430000|J.14|SSCH 10X3X1000 CU/SN|0348900000|H.3|STB 25 IH/GE|0267200000|I.15|STR 5 S F.SCHT 5 S|1631940000|K.17|
|SDI 1.0X4.5X175|9205700000|J.14|SSCH 10X3X1000 CU/SN|0348900000|A.31|STB 25 IH/GN|0271200000|I.20|STR 7 F.SCHT 7|0515300000|K.17|
|SDI 1.0X5.5X175|9205710000|J.14|SSCH 10X3X1000 CU/SN|0348900000|A.30|STB 25 IH/GN|0271200000|I.15|STR 7 F.SCHT 7|0515300000|K.19|
|SDI T10|9009640000|J.14|SSCH 10X3X1000 MS/BK|0259800000|H.3|STB 25 IH/GR|0271400000|I.15|STRIPAX|9005000000|J.4|
|SDI T15|9009650000|J.14|SSCH 10X3X1000 ST/ZN|0438000000|H.3|STB 25 IH/GR|0271400000|I.20|STRIPAX 16|9005610000|J.4|
|SDI T20|9009660000|J.14|SSCH 10X3X1000 ST/ZN|1746130000|G.5|STB 25 IH/RT|0343300000|I.15|STRIPAX PLUS 2.5|9020000000|J.5|
|SDI T25|9009670000|J.14|SSCH 10X3X1000 ST/ZN|1746130000|G.7|STB 25 IH/RT|0343300000|I.20|STRIPAX PLUS 2.5|9020000000|J.35|
|SDI T30|9009680000|J.14|SSCH 10X3X1000 ST/ZN|1746130000|G.4|STB 25 IH/SW|0271500000|I.15|SWIFTY|9006020000|J.13|
|SDI T40|9009690000|J.14|SSCH 15X6X1000 CU/SN|0357400000|H.3|STB 25 IH/SW|0271500000|I.20|SWIFTY SET|9006060000|J.13|
|SDI T8|9201940000|J.14|SSCH 6X6X1000 CU/SN|0571300000|H.3|STB 25 IH/VI|0271300000|I.20||||
|SDIK PH0<br>SDIK PH1|9008560000<br>9008570000|J.14<br>J.14|SSCH 6X6X1000 MS/BK<br>SSP 3 SAKT1|0571200000<br>0531760000|H.3<br>A.33|STB 25 IH/VI<br>STB 28.5 IH/SW SAK2.5|0271300000<br>0133400000|I.15<br>I.15|**T**|||
|SDIK PH2|9008580000|J.14|SSP 3 SAKT1|0531760000|B.31|STB 30.5 IH/BL|0341200000|I.20|TA 1|0535860000|I.14|
|SDIK PH3|9008590000|J.14|SSP 3 SAKT1|0531760000|A.32|STB 30.5 IH/BL|0341200000|I.15|TBS 2|1287860000|I.17|
|SDIK PZ1|9008900000|J.14|SSP 3 SAKT1|0531760000|I.20|STB 30.5 IH/GE|0341500000|I.15|TH-S 9-40|9008880000|J.16|
|SDIK PZ2|9008890000|J.14|SSP 3 SAKT1|0531760000|B.32|STB 30.5 IH/GE|0341500000|I.20|Tinte 2000 25ml|1772120000|K.25|
|SDIZ 0.6X3.5X100|9008450000|J.20|SSP 4 SAKT4|1319360000|I.20|STB 30.5 IH/GN|0341400000|I.20|Tinte 2000 25ml|1772120000|K.24|
|SDIZ 0.8X4.0X100|9008460000|J.20|SSP 4 SAKT4|1319360000|A.33|STB 30.5 IH/GN|0341400000|I.15|Tintenpatrone PrintJet|1797460000|K.22|
|SDK PH0|9008470000|J.15|SSP 4 SAKT4|1319360000|B.32|STB 30.5 IH/GR|0341100000|I.20|Tintentank PrintJet II|1858920000|K.22|
|SDK PH1|9008480000|J.15|ST 5 PA/BE|0448360000|C.6|STB 30.5 IH/GR|0341100000|I.15|TONER SMARK LASER|1770070000|K.21|
|SDK PH2|9008490000|J.15|STA 2.5/2|0165860000|B.43|STB 30.5 IH/RT|0341300000|I.20|TS 15X5 2M/AL/BK|0134700000|H.10|
|SDK PH3|9008500000|J.15|STA 2.5/2|0165860000|A.36|STB 30.5 IH/RT|0341300000|I.15|TS 15X5 2M/ST/ZN|0514200000|H.10|
|SDK PZ0|9008520000|J.15|STA 2.5/2|0165860000|A.37|STB 30.5 IH/SW|0341000000|I.20|TS 15X5/LL 1M/ST/ZN|0117510000|H.10|
|SDK PZ1|9008530000|J.15|STA 2.5/2|0165860000|B.42|STB 30.5 IH/SW|0341000000|I.15|TS 15X5/LL 2M/AL/BK|0217900000|H.10|
|SDK PZ2|9008540000|J.15|STA 2.5/2|0165860000|B.36|STB 30.5 IH/VI|0341600000|I.15|TS 15X5/LL 2M/ST/ZN|0117500000|H.10|
|SDK PZ3|9008550000|J.15|STA 2.5/3|0165960000|A.37|STB 30.5 IH/VI|0341600000|I.20|TS 27X12.5M/ST/F.ZN|1802690000|G.11|
|SH 1|0299860000|H.4|STA 2.5/3|0165960000|B.36|STB 35 IH/BL|0388700000|I.20|TS 32X15 2M/AL/BK|0169300000|H.10|
|SH 2|0494920000|A.14|STA 2.5/3|0165960000|B.42|STB 35 IH/BL|0388700000|I.15|TS 32X15 2M/CRN|0293220000|H.10|
|SH 2|0494920000|A.15|STA 2.5/3|0165960000|B.43|STB 35 IH/GE|0389000000|I.15|TS 32X15 2M/ST/ZN|0122800000|H.10|
|SH 2|0494920000|A.16|STA 2.5/3|0165960000|A.36|STB 35 IH/GE|0389000000|I.20|TS 32X15/LL 2M/ST/ZN|0514400000|H.10|
|SH 2|0494920000|A.17|STA 2.5/4|0190360000|B.42|STB 35 IH/GN|0388900000|I.20|TS 32X16.2 2M/CU/BK|0364300000|H.10|
|SH 2|0494920000|B.15|STA 2.5/4|0190360000|B.36|STB 35 IH/GN|0388900000|I.15|TS 35X15 2M/ST/ZN|0236400000|H.11|
|SH 2|0494920000|H.4|STA 2.5/4|0190360000|A.37|STB 35 IH/GR|0388600000|I.20|TS 35X15/2.3 2M/AL/BK|1848290000|H.11|
|SH 2|0494920000|B.14|STA 2.5/4|0190360000|A.36|STB 35 IH/GR|0388600000|I.15|TS 35X15/2.3 2M/CU/BK|0270100000|H.11|
|SH 2|0494920000|B.13|STA 2.5/4|0190360000|B.43|STB 35 IH/RT|0388800000|I.15|TS 35X15/2.3 2M/ST/ZN|0498000000|H.11|
|SH 2|0494920000|B.12|STA 2.5/5|0166060000|B.42|STB 35 IH/RT|0388800000|I.20|TS 35X15/6X18 2M/ST/ZN|1805980000|H.11|
|SH 2|0494920000|I.12|STA 2.5/5|0166060000|B.43|STB 35 IH/SW|0388500000|I.20|TS 35X15/6X25 2M/ST/ZN|1866290000|H.11|
|SH 2 S|0641720000|H.4|STA 2.5/5|0166060000|B.36|STB 35 IH/SW|0388500000|I.15|TS 35X15/LL 1M/ST/ZN|0236510000|H.11|
|SH 3|0556660000|H.4|STA 2.5/5|0166060000|A.36|STB 35 IH/VI|0389100000|I.20|TS 35X15/LL 2M/ST/ZN|0236500000|H.11|
|SK 10,0x125|9009070000|J.15|STA 2.5/5|0166060000|A.37|STB 35 IH/VI|0389100000|I.15|TS 35X15/LL/5 2M/ST/ZN|1837380000|H.11|
|SK 11,0x125|9009060000|J.15|STA 2.5/8|0166160000|B.42|STB 5.5/D3.7/2.3/M3 ZB|0122700000|I.15|TS 35X7.5 1M/ST/ZN|0383410000|H.11|
|SK 12,0x125|9009050000|J.15|STA 2.5/8|0166160000|A.36|STB 6/D3.7/2.3/M3 SAKR|0379400000|B.16|TS 35X7.5 2M/AL/BK|0330800000|H.11|
|SK 13,0x125|9009040000|J.15|STA 2.5/8|0166160000|B.36|STB 6/D3.7/2.3/M3 SAKR|0379400000|B.18|TS 35X7.5 2M/CRN|1747350000|H.11|
|SK 5,5x125|9009120000|J.15|STA 2.5/8|0166160000|B.43|STB 6/D3.7/2.3/M3 SAKR|0379400000|B.40|TS 35X7.5 2M/ST/ZN|0383400000|H.11|
|SK 6,0x125|9009110000|J.15|STA 2.5/8|0166160000|A.37|STB 6/D3.7/2.3/M3 SAKR|0379400000|A.18|TS 35X7.5/LL 1M/ST/ZN|0514510000|H.11|
|SK 7,0x125|9009100000|J.15|STB 13.5/D6/4/M4 SAKA10|0135200000|B.30|STB 6/D3.7/2.3/M3 SAKR|0379400000|I.15|TS 35X7.5/LL 2M/ST/ZN|0514500000|H.11|
|SK 8,0x125|9009090000|J.15|STB 13.5/D6/4/M4 SAKA10|0135200000|I.15|STB 6/D3.9/2.3/M2.5 ZB|0130200000|B.6|TS 35X7.5/LL/6 2M/ST/ZN|0514570000|H.11|
|SK 9,0x125|9009080000|J.15|STB 14/D5/2.3/M3 SAK2.5|0168600000|A.11|STB 6/D3.9/2.3/M2.5 ZB|0130200000|I.15|TSCH 1|0319160000|A.9|
|SK E14 SAKS4|0339410000|A.26|STB 14/D5/2.3/M3 SAK2.5|0168600000|B.3|STB 7.5/D6/4/M4 ZB/SAKB|0130000000|I.15|TSCH 1|0319160000|B.2|
|SK E14 SAKS4|0339410000|B.24|STB 14/D5/2.3/M3 SAK2.5|0168600000|B.28|STB 7/D4/2.3/M3 ZB/SAKC|0358500000|B.19|TSCH 1|0319160000|A.8|
|SK E14 SAKS4 USA|2012790000|B.25|STB 14/D5/2.3/M3 SAK2.5|0168600000|B.42|STB 7/D4/2.3/M3 ZB/SAKC|0358500000|I.15|TSCH 1|0319160000|A.37|
|SK E14 SAKS4 USA|2012790000|A.27|STB 14/D5/2.3/M3 SAK2.5|0168600000|B.43|STB 8.5/5/2.3/M3 SAK2.5|0280600000|B.32|TSCH 1|0319160000|A.7|
|SK E16/SAKS2|0284110000|A.26|STB 14/D5/2.3/M3 SAK2.5|0168600000|I.15|STB 8.5/5/2.3/M3 SAK2.5|0280600000|B.38|TSCH 1|0319160000|B.4|
|SK E16/SAKS2|0284110000|B.24|STB 14/D5/2.3/M3 SAK2.5|0168600000|B.6|STB 8.5/5/2.3/M3 SAK2.5|0280600000|B.39|TSCH 1|0319160000|B.39|
|SK E18 SAKS5|0359310000|B.25|STB 14/D5/2.3/M3 SAK2.5|0168600000|D.6|STB 8.5/5/2.3/M3 SAK2.5|0280600000|C.2|TSCH 1|0319160000|A.2|
|SK E18 SAKS5|0359310000|A.27|STB 14/D5/2.3/M3 SAK2.5|0168600000|C.5|STB 8.5/5/2.3/M3 SAK2.5|0280600000|A.2|TSCH 1|0319160000|B.3|
|SK WSD-S 1,5-10,0|9008850000|J.16|STB 14/D5/2.3/M3 SAK2.5|0168600000|A.36|STB 8.5/5/2.3/M3 SAK2.5|0280600000|I.15|TSCH 1|0319160000|C.3|
|SKI 10,0x125|9008940000|J.14|STB 14/D5/2.3/M3 SAK2.5|0168600000|A.37|STB 8.5/5/2.3/M3 SAK2.5|0280600000|B.2|TSCH 1|0319160000|A.11|
|SKI 11,0x125|9008930000|J.14|STB 14/D5/2.3/M3 SAK2.5|0168600000|B.36|STB 8.5/5/2.3/M3 SAK2.5|0280600000|B.45|TSCH 1|0319160000|A.36|
|SKI 13,0x125|9008920000|J.14|STB 14/D5/2.3/M3 SAK2.5|0168600000|A.7|STB 8.5/5/2.3/M3 SAK2.5|0280600000|A.40|TSCH 1|0319160000|B.28|
|SKI 5,0x125|9009000000|J.14|STB 14/D5/2.3/M3 SAK2.5|0168600000|A.3|STB 8.5/5/2.3/M3 SAK2.5|0280600000|A.7|TSCH 1|0319160000|C.2|
|SKI 5,5x125|9008990000|J.14|STB 14/D5/2.3/M3 SAK2.5|0168600000|C.4|STB 8.5/D4.5/2/M3 SAKT4|0244600000|I.15|TSCH 1|0319160000|C.4|
|SKI 6,0x125|9008980000|J.14|STB 14/D5/2.3/M3 SAK2.5|0168600000|C.2|STB 8.5/D4.5/2/M3 SAKT4|0244600000|A.33|TSCH 1|0319160000|B.7|
|SKI 7,0x125|9008970000|J.14|STB 14/D6/4/M3 SAK10|0169900000|B.32|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|A.2|TSCH 1|0319160000|C.5|
|SKI 8,0x125|9008960000|J.14|STB 14/D6/4/M3 SAK10|0169900000|A.3|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|B.2|TSCH 1|0319160000|B.38|
|SKI 9,0x125|9008950000|J.14|STB 14/D6/4/M3 SAK10|0169900000|A.9|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|A.13|TSCH 1|0319160000|B.36|
|SKS 2,0-8,0|9008860000|J.16|STB 14/D6/4/M3 SAK10|0169900000|B.3|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|B.11|TSCH 1|0319160000|A.3|
|SKS 2,0-8,0 MR|9008870000|J.16|STB 14/D6/4/M3 SAK10|0169900000|B.4|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|B.10|TSCH 1|0319160000|B.6|
|SMSE WSH U1|1083900000|G.7|STB 14/D6/4/M3 SAK10|0169900000|B.7|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|B.59|TSCH 1|0319160000|B.42|
|Snap Mark I|1805880000|K.16|STB 14/D6/4/M3 SAK10|0169900000|A.33|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|E.9|TSCH 1|0319160000|B.45|
|SO SH1|0401460000|H.4|STB 14/D6/4/M3 SAK10|0169900000|A.8|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|A.53|TSCH 1|0319160000|A.4|
|SP 15|3896100000|G.9|STB 14/D6/4/M3 SAK10|0169900000|I.20|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|E.10|TSCH 1|0319160000|B.43|
|SP 20|3896200000|G.9|STB 14/D6/4/M3 SAK10|0169900000|A.4|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|B.60|TSCH 1|0319160000|A.40|
|SP 30|3896300000|G.9|STB 14/D6/4/M3 SAK10|0169900000|A.32|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|I.15|TSCH 2|0353660000|A.33|
|SPEEDMARKING-LASER|1767090000|K.21|STB 14/D6/4/M3 SAK10|0169900000|C.3|STB 8.5/D4/2.3/M2.5 AKZ|0215700000|A.52|TSCH 2|0353660000|B.31|
**X.11**
**X**
|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|TSCH 2|0353660000|B.32|TW SAK2.5 KRG/BL|0302870000|B.6|VH 10/4/2.8 AKZ4|0446600000|A.56|VL 2 SAK16/SAKA|0135800000|A.9|
|TSCH 2|0353660000|A.32|TW SAK2.5 KRG/BL|0302870000|A.7|VH 10/4/2.8 AKZ4|0446600000|A.55|VL 2 SAK16/SAKA|0135800000|B.4|
|TSCH 3 SAKD2.5 N|0366860000|B.2|TW SAK2.5-35/32 KRG|0257120000|B.30|VH 10/4/2.8 AKZ4|0446600000|E.12|VL 2 SAK16/SAKA|0135800000|C.3|
|TSCH 3 SAKD2.5 N|0366860000|A.2|TW SAK35|0304360000|A.5|VH 10/4/2.8 AKZ4|0446600000|B.56|VL 2 SAK16/SAKA|0135800000|B.7|
|TSCH 4 AKZ4|0363360000|E.13|TW SAK35|0304360000|C.4|VH 10/4/2.8 AKZ4|0446600000|A.50|VL 2 SAK35|0124000000|A.4|
|TSCH 4 AKZ4|0363360000|A.55|TW SAK35|0304360000|B.4|VH 10/4/2.8 AKZ4|0446600000|A.54|VL 2 SAK35|0124000000|B.4|
|TSCH 4 AKZ4|0363360000|B.57|TW SAK35|0304360000|A.4|VH 10/4/2.8 AKZ4|0446600000|B.59|VL 2 SAK35|0124000000|B.5|
|TSCH 4 AKZ4|0363360000|A.51|TW SAK35|0304360000|B.5|VH 12.5 SAKK10|9502690000|D.3|VL 2 SAK35|0124000000|A.5|
|TSCH 4 AKZ4|0363360000|A.53|TW SAK35 KRG|0304320000|B.9|VH 12.5 SAKK10|9509510000|D.3|VL 2 SAK35|0124000000|I.12|
|TSCH 4 AKZ4<br>TSCH 4 AKZ4<br>TSCH 4 AKZ4|0363360000<br>0363360000<br>0363360000|E.3<br>A.54<br>A.52|TW SAK35 KRG<br>TW SAK35 KRG<br>TW SAK4-10 EP/SW|0304320000<br>0304320000<br>0130100000|A.9<br>B.8<br>D.6|VH 12.5/5/3.5 SAK10-2.5<br>VH 12/4.9/3.3 SAK6N<br>VH 12/4.9/3.3 SAK6N|0300800000<br>0249000000<br>0249000000|I.10<br>B.32<br>B.31|VL 2 SAK35<br>VL 2 SAK4<br>VL 2 SAK4|0124000000<br>0197000000<br>0197000000|B.8<br>I.12<br>C.4|
|TSCH 4 AKZ4|0363360000|E.12|TW SAK4-10 KRG|0130120000|A.8|VH 12/4.9/3.3 SAK6N|0249000000|I.10|VL 2 SAK4|0197000000|C.2|
|TSCH 4 AKZ4|0363360000|E.11|TW SAK4-10 KRG|0130120000|B.44|VH 12/4.9/3.3 SAK6N|0249000000|A.32|VL 2 SAK4|0197000000|B.6|
|TSCH 4 AKZ4|0363360000|B.60|TW SAK4-10 KRG|0130120000|A.20|VH 12/4.9/3.3 SAK6N|0249000000|I.21|VL 2 SAK4|0197000000|A.7|
|TSCH 4 AKZ4|0363360000|B.56|TW SAK4-10 KRG|0130120000|B.6|VH 12/4.9/3.3 SAK6N|0249000000|I.9|VL 2 SAK4|0197000000|C.5|
|TSCH 4 AKZ4|0363360000|B.59|TW SAK4-10 KRG|0130120000|A.7|VH 12/4.9/3.3 SAK6N|0249000000|A.33|VL 2 SAK4|0197000000|B.3|
|TSCH 4 AKZ4|0363360000|B.38|TW SAK4-10 KRG|0130120000|B.7|VH 12/4.9/3.3 SAK6N|0249000000|<br>I.9|VL 2 SAK4|0197000000|A.3|
|TSCH 4 AKZ4|0363360000|A.50|TW SAK4-10 KRG|0130120000|B.19|VH 13.5 SAKK 4|9502580000|D.2|VL 2 SAK6/10/SAKB|0135900000|B.7|
|TSCH 4 AKZ4|0363360000|B.61|TW SAK4-10 KRG/BL|0130170000|A.8|VH 13.5 SAKK4|9509460000|D.2|VL 2 SAK6/10/SAKB|0135900000|A.3|
|TSCH 4 AKZ4|0363360000|E.10|TW SAK4-10 KRG/BL|0130170000|A.7|VH 13.5/4.9/3.3 SAK4|0248500000|A.11|VL 2 SAK6/10/SAKB|0135900000|B.3|
|TSCH 4 AKZ4|0363360000|B.58|TW SAK4-10 KRG/BL|0130170000|A.20|VH 13.5/4.9/3.3 SAK4|0248500000|I.9|VL 2 SAK6/10/SAKB|0135900000|I.12|
|TSCH 6 DKI S4|0190260000|B.37|TW SAK4-10 KRG/BL|0130170000|B.19|VH 13.5/4.9/3.3 SAK4|0248500000|I.10|VL 2 SAK6/10/SAKB|0135900000|A.8|
|TSCH 6 DKI S4|0190260000|A.38|TW SAK4-10 KRG/BL|0130170000|B.7|VH 13.5/4.9/3.3 SAK4|0248500000|B.28|VL 2 SAK6N/SAKT|0194700000|A.8|
|TSCH 6 DKI S4|0190260000|A.39|TW SAK4-10 KRG/BL|0130170000|B.6|VH 13.6/7/4.2 SAKA10|0299700000|A.20|VL 2 SAK6N/SAKT|0194700000|A.3|
|TSCH 6 DKI S4|0190260000|B.10|TW SAK4-10 KRG/BL|0130170000|B.44|VH 13.6/7/4.2 SAKA10|0299700000|B.19|VL 2 SAK6N/SAKT|0194700000|C.3|
|TSCH 6 DKI S4|0190260000|A.12|TW SAKB/C/T1|0242960000|A.20|VH 13/5/3.5 SAK 10|0304000000|I.10|VL 2 SAK6N/SAKT|0194700000|B.7|
|TSCH 6 DKI S4|0190260000|B.11|TW SAKB/C/T1|0242960000|B.32|VH 16/5/3.5 SAK10-35|0309700000|I.10|VL 2 SAK6N/SAKT|0194700000|B.28|
|TSCH 6 DKI S4|0190260000|A.13|TW SAKB/C/T1|0242960000|A.32|VH 16/5/3.5 SAK10-35|0309700000|A.33|VL 2 SAK6N/SAKT|0194700000|I.12|
|TSK 31.5 GR|0347960000|I.16|TW SAKB/C/T1|0242960000|A.33|VH 16/5/3.5 SAK10-35|0309700000|B.32|VL 2 SAK6N/SAKT|0194700000|A.11|
|TSK 35X15 2M PVC/GR|0514300000|H.12|TW SAKB/C/T1|0242960000|B.31|VH 17/8/5 SAK35|0267000000|A.9||||
|TST 2/M5<br>TST 2/M6|1286600000<br>0101700000|H.14<br>H.14|TW SAKB-C-T<br>TW SAKB-C-T|0242920000<br>0242920000|B.30<br>A.20|VH 17/8/5 SAK35<br>VH 17/8/5 SAK35|0267000000<br>0267000000|B.4<br>I.10|**W**|||
|TSTW 5/M5|0178100000|H.14|TW SAKB-C-T|0242920000|B.19|VH 17/8/5 SAK35|0267000000|B.9|WAD 12 M. BL.|1055960000|K.18|
|TSTW 5/M5 ZN|1779100000|H.14|TW SAKD2.5N|0191860000|A.2|VH 17/8/5 SAK35|0267000000|A.5|WAD 12 NEUTRAL|1056260000|K.18|
|TSTW 6/M6|0164000000|H.14|TW SAKD2.5N|0191860000|B.2|VH 17/8/5 SAK35|0267000000|B.5|WAD 27 M. BL.|1062860000|K.18|
|TSTW D 4.3|1610110000|H.14|TW SAKD2.5N BL|0191880000|B.2|VH 17/8/5 SAK35|0267000000|A.4|WAD 27 NEUTRAL|1062960000|K.18|
|TW 4 SAK4-10|0130160000|C.4|TW SAKD2.5N BL|0191880000|A.2|VH 17/8/5 SAK35|0267000000|C.4|WAD 5 M. BL.|1053460000|K.18|
|TW 4 SAK4-10|0130160000|C.5|TW SAKG28 HP/DBR/2|0151400000|B.47|VH 17/8/5 SAK35|0267000000|B.8|WAD 5 NEUTRAL|1056060000|K.18|
|TW 4 SAK4-10|0130160000|B.3|TW SAKG28 HP/DBR/2|0151400000|B.46|VH 17/8/5 SAK35|0267000000|<br>I.9|WAD 5 Sonderdruck|1790060000|K.18|
|TW 4 SAK4-10|0130160000|B.37|TW SAKG28 HP/DBR/2|0151400000|B.48|VH 19/5/3.5 SAK4-16|0285100000|B.6|WAD 8 M. BL.|1053560000|K.18|
|TW 4 SAK4-10|0130160000|A.38|TW SAKG28 HP/DBR/2|0151400000|A.44|VH 19/5/3.5 SAK4-16|0285100000|B.3|WAD 8 NEUTRAL|1056160000|K.18|
|TW 4 SAK4-10|0130160000|C.2|TW SAKG28 HP/DBR/2|0151400000|B.49|VH 19/5/3.5 SAK4-16|0285100000|B.7|WAD 8 SONDERDRUCK|1667700000|K.18|
|TW 4 SAK4-10|0130160000|A.37|TW SAKG28 HP/DBR/2|0151400000|A.43|VH 19/5/3.5 SAK4-16|0285100000|A.4|WAW 1 NEUTRAL|9004500000|J.3|
|TW 4 SAK4-10|0130160000|A.36|TW SAKG28 HP/DBR/2|0151400000|B.50|VH 19/5/3.5 SAK4-16|0285100000|B.4|WAW 2|9004510000|J.3|
|TW 4 SAK4-10|0130160000|B.44|TW SAKG28 HP/TF/GE/2|0164600000|A.43|VH 19/5/3.5 SAK4-16|0285100000|A.3|WEW 32/1|1067600000|H.13|
|TW 4 SAK4-10|0130160000|A.3|TW SAKG28 HP/TF/GE/2|0164600000|A.44|VH 19/5/3.5 SAK4-16|0285100000|C.5|WEW 35/1|1059000000|H.5|
|TW 4 SAK4-10|0130160000|C.3|TW SAKG28 HP/TF/GE/2|0164600000|B.47|VH 19/5/3.5 SAK4-16|0285100000|A.8|WEW 35/2|1061200000|H.13|
|TW 4 SAK4-10 BL|0130180000|C.5|TW SAKG28 HP/TF/GE/2|0164600000|B.50|VH 19/5/3.5 SAK4-16|0285100000|C.2|WEW 35/2|1061200000|H.5|
|TW 4 SAK4-10 BL|0130180000|C.4|TW SAKG28 HP/TF/GE/2|0164600000|B.46|VH 19/5/3.5 SAK4-16|0285100000|I.12|WGB 5 ABDG.M.GRUPPENBEZ|1050760000|K.18|
|TW 4 SAK4-10 BL|0130180000|A.3|TW SAKG28 HP/TF/GE/2|0164600000|B.48|VH 19/5/3.5 SAK4-16|0285100000|C.3|WGB 8 ABDG.M.GRUPPENBEZ|1050960000|K.18|
|TW 4 SAK4-10 BL|0130180000|C.3|TW SAKG28 HP/TF/GE/2|0164600000|B.49|VH 19/5/3.5 SAK4-16|0285100000|A.7|WK IK PH0|9918460000|J.19|
|TW 4 SAK4-10 BL|0130180000|C.2|TW SAKG46 HP/DBR/2|0177100000|B.52|VH 19/5/3.5 SAK4-16|0285100000|C.4|WK IK PH1|9918470000|J.19|
|TW 4 SAK4-10 BL|0130180000|B.3|TW SAKG46 HP/DBR/2|0177100000|A.42|VH 19/5/3.5 SAK4-16|0285100000|A.9|WK IK PH2|9918480000|J.19|
|TW ADK1 HP/DBR/0.5|0442300000|E.11|TW SAKG46 HP/DBR/2|0177100000|B.49|VH 19/6/4.2 SAKT1|0318000000|B.32|WK IK PZ0|9918490000|J.19|
|TW AKZ2.5|0318560000|E.2|TW SAKG46 HP/DBR/2|0177100000|A.43|VH 19/6/4.2 SAKT1|0318000000|A.32|WK IK PZ1|9918500000|J.19|
|TW AKZ2.5|0318560000|E.13|TW SAKG46 HP/DBR/2|0177100000|A.47|VH 19/6/4.2 SAKT1|0318000000|A.33|WK IK PZ2|9918510000|J.19|
|TW AKZ2.5 BL|0318580000|E.2|TW SAKG46 HP/DBR/2|0177100000|B.53|VH 19/6/4.2 SAKT1|0318000000|B.31|WK K PH0|9918570000|J.18|
|TW AKZ4|0348260000|E.9|TW SAKG46 HP/DBR/2|0177100000|B.48|VH 19/6/4.2 SAKT1|0318000000|I.21|WK K PH1|9918580000|J.18|
|TW AKZ4|0348260000|E.13|TW SAKG46 HP/DBR/2|0177100000|A.44|VH 21/5/3.5 SAK16-35|0309600000|A.11|WK K PH2|9918590000|J.18|
|TW AKZ4|0348260000|E.12|TW SAKG46 HP/DBR/2|0177100000|B.50|VH 21/5/3.5 SAK16-35|0309600000|B.28|WK K PZ0|9918600000|J.18|
|TW AKZ4|0348260000|E.3|TW SAKG46 HP/DBR/2|0177100000|A.46|VH 23/6/4.2 SAKA10|0348700000|B.30|WK K PZ1|9918610000|J.18|
|TW AKZ4|0348260000|E.8|TW SAKG46 HP/DBR/2|0177100000|B.51|VH 24.5/8/5 SAK35|0298700000|A.5|WK K PZ2|9918620000|J.18|
|TW AKZ4|0348260000|E.11|TW SAKG46 HP/DBR/2|0177100000|A.45|VH 24.5/8/5 SAK35|0298700000|B.8|WK S 0,4x2,5|9918520000|J.18|
|TW AKZ4|0348260000|E.10|TW SAKG46 HP/TF/GE/2|0179900000|B.52|VH 24.5/8/5 SAK35|0298700000|A.4|WK S 0,5x3,0|9918530000|J.18|
|TW AKZ4 BL|0348280000|E.3|TW SAKG46 HP/TF/GE/2|0179900000|A.42|VH 24.5/8/5 SAK35|0298700000|B.5|WK S 0,6x3,5|9918540000|J.18|
|TW AKZ4 HP/DBR/0.5|0166800000|E.10|TW SAKG46 HP/TF/GE/2|0179900000|A.45|VH 24.5/8/5 SAK35|0298700000|I.12|WK S 0,8x4,0|9918550000|J.18|
|TW AST1/PA HP/DBR/0.5|0474700000|A.11|TW SAKG46 HP/TF/GE/2|0179900000|B.49|VH 24.5/8/5 SAK35|0298700000|B.4|WK S 1,0x5,5|9918560000|J.18|
|TW AST1/PA HP/DBR/0.5|0474700000|B.28|TW SAKG46 HP/TF/GE/2|0179900000|B.48|VH 27/5/3.5 SAK10-35|0309400000|I.10|WK SI 0,4x2,5|9918410000|J.19|
|TW AST1/PA HP/DBR/0.5|0474700000|A.37|TW SAKG46 HP/TF/GE/2|0179900000|A.44|VH 27/5/3.5 SAK10-35|0309400000|B.28|WK SI 0,5x3,0|9918420000|J.19|
|TW AST1/PA HP/DBR/0.5|0474700000|B.41|TW SAKG46 HP/TF/GE/2|0179900000|B.53|VH 30.5/11/5.5 SAK70|0345500000|I.9|WK SI 0,6x3,5|9918430000|J.19|
|TW AST1/PA HP/DBR/0.5|0474700000|B.32|TW SAKG46 HP/TF/GE/2|0179900000|B.50|VH 30.5/11/5.5 SAK70|0345500000|B.9|WK SI 0,8x4,0|9918440000|J.19|
|TW AST1/PA HP/DBR/0.5|0474700000|A.33|TW SAKG46 HP/TF/GE/2|0179900000|A.47|VH 30.5/11/5.5 SAK70|0345500000|A.6|WK SI 1,0x5,5|9918450000|J.19|
|TW AST1/PA HP/DBR/0.5|0474700000|B.36|TW SAKG46 HP/TF/GE/2|0179900000|B.51|VH 35/11/5.5 SAK95|0551100000|I.9|WS 10/12 MC NEUTRAL|1905970000|K.15|
|TW KST5-12 LI/NO 160/HM|1752800000|A.49|TW SAKG46 HP/TF/GE/2|0179900000|A.46|VH 35/11/5.5 SAK95|0551100000|B.9|WS 10/12 MC SONDERDRUCK|1906060000|K.15|
|TW KST5-12 LI/NO 160/HM|1752800000|A.48|TW SAKG46 HP/TF/GE/2|0179900000|A.43|VH 35/11/5.5 SAK95|0551100000|A.10|WS 10/15 MC Neutr.|1854090000|K.15|
|TW KST5-12 LI/NO 160/HM|1752800000|B.55|TW SAKS2 HP/DBR/2|0607000000|B.36|VH 4.5/5/3.5 SAK6N-16|0303200000|I.10|WS 10/15 MC Sonderdruck|1854100000|K.15|
|TW KST5-12 LI/NO 160/HM|1752800000|B.54|TW SAKS2 HP/DBR/2|0607000000|A.36|VH 5/4/2.8 AKZ4|0296800000|I.9|WS 10/5 MC BEDRUCKT|1635010000|K.14|
|TW KST5-12 RE/NO 160/HM|1718530000|B.55|TW SAKS2 HP/DBR/2|0607000000|B.40|VH 8/4.9/3.3 SAK2.5|0266700000|I.10|WS 10/5 MC Midd. Neutr.|1792000000|K.16|
|TW KST5-12 RE/NO 160/HM|1718530000|A.49|TW SAKS2 HP/DBR/2|0607000000|B.42|VH 8/4.9/3.3 SAK2.5|0266700000|B.32|WS 10/5 MC Midd. Neutr.|1792000000|K.14|
|TW KST5-12 RE/NO 160/HM|1718530000|B.54|TW SAKS2 HP/DBR/2|0607000000|B.34|VH 8/4.9/3.3 SAK2.5|0266700000|A.33|WS 10/5 MC Midd. Neutr.|1792000000|K.17|
|TW KST5-12 RE/NO 160/HM|1718530000|A.48|TW SAKS2 HP/DBR/2|0607000000|A.34|VH 8/4.9/3.3 SAK2.5|0266700000|I.9|WS 10/5 MC Midd. Sonder|1792010000|K.14|
|TW SAK16 KRG|0281120000|B.7|TW SAKS2 HP/DBR/2|0607000000|B.43|VL 2 AKZ4/DK4|0446700000|A.54|WS 10/5 MC NEUTRAL|1635000000|K.16|
|TW SAK16 KRG|0281120000|A.9|TW SAKS2 HP/DBR/2|0607000000|B.17|VL 2 AKZ4/DK4|0446700000|E.11|WS 10/5 MC NEUTRAL|1635000000|K.14|
|TW SAK2.5|0302860000|A.40|TW SAKS2 HP/DBR/2|0607000000|B.38|VL 2 AKZ4/DK4|0446700000|E.10|WS 10/5 MC neutral BL|1773531693|K.14|
|TW SAK2.5|0302860000|A.2|TW SAKS2 HP/DBR/2|0607000000|B.39|VL 2 AKZ4/DK4|0446700000|B.60|WS 10/5 MC neutral GE|1773531687|K.14|
|TW SAK2.5|0302860000|B.39|TW SAKS2 HP/DBR/2|0607000000|B.45|VL 2 AKZ4/DK4|0446700000|E.12|WS 10/5 MC neutral RT|1773531686|K.14|
|TW SAK2.5|0302860000|B.38|TW SAKT2|0351820000|A.33|VL 2 AKZ4/DK4|0446700000|A.56|WS 10/5 Sonderdr. Laser|1773370000|K.9|
|TW SAK2.5|0302860000|B.34|TW ST5 PA/BE|0477660000|C.6|VL 2 AKZ4/DK4|0446700000|A.55|WS 10/6 MC Midd. Neutr.|1818400000|K.14|
|TW SAK2.5|0302860000|B.2||||VL 2 AKZ4/DK4|0446700000|A.50|WS 10/6 MC Midd. Sonder|1818410000|K.15|
|TW SAK2.5<br>TW SAK2.5 BL|0302860000<br>0302880000|C.2<br>A.2|**V**|||VL 2 AKZ4/DK4<br>VL 2 AKZ4/DK4|0446700000<br>0446700000|B.59<br>B.56|WS 10/6 MC MIDDLE GE<br>WS 10/6 MC MIDDLE GN|1917430000<br>1917420000|K.14<br>K.14|
|TW SAK2.5 BL|0302880000|C.2|VH 10/4/2.8 AKZ4|0446600000|A.52|VL 2 AKZ4/DK4|0446700000|A.51|WS 10/6 MC MIDDLE OR|1917410000|K.14|
|TW SAK2.5 BL|0302880000|B.2|VH 10/4/2.8 AKZ4|0446600000|E.11|VL 2 AKZ4/DK4|0446700000|A.53|WS 10/6 MC MIDDLE RT|1917440000|K.14|
|TW SAK2.5 BL|0302880000|B.39|VH 10/4/2.8 AKZ4|0446600000|B.57|VL 2 AKZ4/DK4|0446700000|B.57|WS 10/6 MC NEUTRAL|1828450000|K.14|
|TW SAK2.5 HP/TF/GE/1|0297100000|B.16|VH 10/4/2.8 AKZ4|0446600000|B.60|VL 2 AKZ4/DK4|0446700000|B.58|WS 10/6 MC Sonderdruck|1828460000|K.15|
|TW SAK2.5 HP/TF/GE/1|0297100000|B.18|VH 10/4/2.8 AKZ4|0446600000|A.53|VL 2 AKZ4/DK4|0446700000|A.52|WS 10/8 MC NEUTRAL|1905950000|K.15|
|TW SAK2.5 HP/TF/GE/1|0297100000|A.40|VH 10/4/2.8 AKZ4|0446600000|B.58|VL 2 RSF 1+2|0528400000|B.28|WS 10/8 MC SONDERDRUCK|1906030000|K.15|
|TW SAK2.5 KRG|0302820000|A.7|VH 10/4/2.8 AKZ4|0446600000|A.51|VL 2 SAK16/SAKA|0135800000|A.4|WS 12/3,5 MC neutral|1778270000|K.14|
|TW SAK2.5 KRG|0302820000|B.6|VH 10/4/2.8 AKZ4|0446600000|E.10|VL 2 SAK16/SAKA|0135800000|I.12|WS 12/3,5 MC Sonderdr.|1778280000|K.14|
**X.12**
|**Type**|**Order No.**|**Page**|**Type**|**Order No.**|**Page**|
|---|---|---|---|---|---|
|WS 12/5 FSZ 1-10|1773430001|K.9|ZEW 35/2|8630740000|H.13|
|WS 12/5 FSZ 11-20|1773430011|K.9|ZF 4 S|1814680000|H.7|
|WS 12/5 FSZ 21-30|1773430021|K.9|ZF 4 S BL|1814660000|H.7|
|WS 12/5 FSZ 31-40|1773430031|K.9|ZF 4 S GN|1814670000|H.7|
|WS 12/5 FSZ 41-50|1773430041|K.9|ZGB 15|1636530000|K.19|
|WS 12/5 FWZ 1-10|1773330001|K.9|ZGB 30|1611930000|K.19|
|WS 12/5 FWZ 11-20|1773330011|K.9|ZS 10/5 MC BEDRUCKT|1610010000|K.15|
|WS 12/5 FWZ 21-30|1773330021|K.9|ZS 10/5 MC NEUTRAL|1610000000|K.15|
|WS 12/5 FWZ 31-40|1773330031|K.9|ZS 12/6 BEDRUCKT|1610030000|K.15|
|WS 12/5 FWZ 41-50<br>WS 12/5 MC BEDRUCKT<br>WS 12/5 MC NEUTRAL|1773330041<br>1609870000<br>1609860000|K.9<br>K.14<br>K.14|ZS 12/6 MC NEUTRAL<br>ZS 15/5 MC BEDRUCKT<br>ZS 15/5 MC NEUTRAL|1610020000<br>1646640000<br>1646630000|K.15<br>K.15<br>K.15|
|WS 12/5 MC NEUTRAL|1609860000|K.18|ZS 2.3/4|0249600000|I.14|
|WS 12/5 MC NEUTRAL|1609860000|K.19|ZU 1|0240600000|I.5|
|WS 12/5 MC neutral BL|1773541693|K.14||||
|WS 12/5 MC neutral GE|1773541687|K.14||||
|WS 12/5 MC neutral OR|1773541690|K.14||||
|WS 12/5 MC neutral RT|1773541686|K.14||||
|WS 12/5 PLUS MC NEUTRAL|1927510000|K.14||||
|WS 12/5 PLUS SONDERDRUCK|1927520000|K.14||||
|WS 12/5 Sonderdr. Laser|1773380000|K.9||||
|WS 12/6 MC BEDRUCKT|1609910000|K.15||||
|WS 12/6 MC NEUTRAL|1609900000|K.14||||
|WS 12/6 MC neutral BL|1773551693|K.14||||
|WS 12/6 MC neutral BR|1773551692|K.14||||
|WS 12/6 MC neutral GE|1773551687|K.14||||
|WS 12/6 MC neutral OR|1773551690|K.14||||
|WS 12/6 MC neutral RT|1773551686|K.14||||
|WS 12/6 MC neutral VI|1773551689|K.14||||
|WS 12/6 PLUS MC NEUTRAL|1927530000|K.14||||
|WS 12/6 PLUS SONDERDRUCK|1927540000|K.15||||
|WS 12/6,5 MC BEDRUCKT|1609930000|K.15||||
|WS 12/6,5 MC NEUTRAL|1609920000|K.15||||
|WS 12/6,5 MC neutral BL|1773561693|K.15||||
|WS 12/6,5 MC neutral GE|1773561687|K.15||||
|WS 12/6,5 MC neutral GN|1773561688|K.15||||
|WS 12/6,5 MC neutral RT|1773561686|K.15||||
|WS 12/8 MC NEUTRAL|1906000000|K.15||||
|WS 12/8 MC SONDERDRUCK|1906010000|K.15||||
|WS 14/5 MC NEUTRAL|1768090000|K.14||||
|WS 15/5 MC BEDRUCKT|1609890000|K.14||||
|WS 15/5 MC NEUTRAL|1609880000|K.14||||
|WS 15/5 MC neutral GE|1773571687|K.14||||
|WS 8/5 MC BEDRUCKT|1640750000|K.14||||
|WS 8/5 MC NEUTRAL|1640740000|K.14||||
|WS 8/5 MC neutral BL|1773521693|K.14||||
|WS 8/5 MC neutral GE|1773521687|K.14||||
|WS 8/5 MC neutral OR|1773521690|K.14||||
|WS 8/5 MC neutral RT|1773521686|K.14||||
|WS 8/5 PLUS MC NEUTRAL|1951870000|K.14||||
|WS 8/5 Sonderdr. Laser|1773360000|K.9||||
|WS 8/6 PLUS MC NEUTRAL|1951880000|K.14||||
|WSH 1|1068700000|G.6||||
|WSH 18 MT|1083100000|G.7||||
|WSH 19 MT|1083200000|G.7||||
|WSH 20 MT|1752950000|G.7||||
|WSH 3/H/N|1715970000|G.6||||
|WSH 4 MT|1079900000|G.9||||
|WSH 5|1080100000|G.6||||
|WSH 6|1080200000|G.6||||
|WTW EN|1058800000|A.12||||
|WTW EN|1058800000|B.10||||
|WTW EN|1058800000|A.13||||
|WTW EN|1058800000|A.34||||
|WTW EN|1058800000|B.11||||
|WTW EN|1058800000|B.34||||
|**Z**||||||
|ZB 10 F.10X3/10X5/10X10|1261300000|H.6||||
|ZB 16 ZKSC|0316600000|A.30||||
|ZB 16 ZKSC|0316600000|A.31||||
|ZB 16 ZKSC|0316600000|H.6||||
|ZB 16/6|0556800000|H.6||||
|ZB 16/6K GE/GN|0569660000|H.7||||
|ZB 16K BL|0502880000|H.7||||
|ZB 16K GE/GN|0502860000|H.7||||
|ZB 35/M6X16|0266500000|A.30||||
|ZB 35/M6X16|0266500000|A.31||||
|ZB 35/M6X16|0266500000|H.6||||
|ZB 35K BL M6X16|0502680000|H.7||||
|ZB 35K GE/GN M6X16|0502660000|H.7||||
|ZB 35K SW M6X16|0502610000|H.7||||
|ZB 4|0316500000|H.6||||
|ZB 4|0316500000|A.30||||
|ZB 4|0316500000|A.31||||
|ZB 4/6|0556700000|H.6||||
|ZB 4/6K BL|0565480000|H.7||||
|ZB 4/6K GE/GN|0565460000|H.7||||
|ZB 4G BL|0322180000|H.7||||
|ZB 4G GN/GE|0322160000|H.7||||
|ZB 4G SW|0322110000|H.7||||
|ZB 4K BL|0475380000|H.7||||
|ZB 4K GE/GN|0475360000|H.7||||
|ZBE 6|0459500000|H.6||||
|ZBE 6K BL|0525980000|H.7||||
|ZBE 6K GE/GN|0525960000|H.7||||
|ZBE 6K SW|0525910000|H.7||||
|ZEW 15|7920340000|H.13||||
|ZEW 35|9540000000|H.13||||
**Type**
**Order No. Page Type Order No. Page**
**X**
**X.13**
**X**
|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|**0050000000**|||0123700000<br>0123700000|QL 3 SAK35<br>QL 3 SAK35|A.5<br>I.9|0130600000<br>0130600000|QL 2 SAK4<br>QL 2 SAK4|B.44<br>B.37|0135800000<br>0135800000|VL 2 SAK16/SAKA<br>VL 2 SAK16/SAKA|A.9<br>B.4|
|0053160000|DK 4/35 RC 220R/220N|A.56|0123700000|QL 3 SAK35|B.5|0130600000|QL 2 SAK4|A.37|0135800000|VL 2 SAK16/SAKA|C.3|
||||0123800000|QL 4 SAK35|A.4|0130600000|QL 2 SAK4|I.10|0135800000|VL 2 SAK16/SAKA|B.7|
|**0100000000**|||0123800000<br>0123800000|QL 4 SAK35<br>QL 4 SAK35|I.9<br>C.4|0130600000<br>0130700000|QL 2 SAK4<br>QL 3 SAK4|I.9<br>A.37|0135900000<br>0135900000|VL 2 SAK6/10/SAKB<br>VL 2 SAK6/10/SAKB|B.7<br>A.3|
|0101700000|TST 2/M6|H.14|0123800000|QL 4 SAK35|B.5|0130700000|QL 3 SAK4|I.9|0135900000|VL 2 SAK6/10/SAKB|B.3|
|0103300000|BFSC M4X9T|A.26|0123800000|QL 4 SAK35|B.4|0130700000|QL 3 SAK4|A.38|0135900000|VL 2 SAK6/10/SAKB|I.12|
|0103300000<br>0103300000<br>0103300000<br>0103300000|BFSC M4X9T<br>BFSC M4X9T<br>BFSC M4X9T<br>BFSC M4X9T|B.24<br>B.25<br>A.27<br>B.30|0123800000<br>0123800000<br>0124000000<br>0124000000|QL 4 SAK35<br>QL 4 SAK35<br>VL 2 SAK35<br>VL 2 SAK35|B.8<br>A.5<br>A.4<br>B.4|0130700000<br>0130700000<br>0130800000<br>0130800000|QL 3 SAK4<br>QL 3 SAK4<br>QL 4 SAK4<br>QL 4 SAK4|B.44<br>B.37<br>B.44<br>B.37|0135900000<br>0136400000<br>0136400000<br>0136400000|VL 2 SAK6/10/SAKB<br>SS M4 D 128-A 4<br>SS M4 D 128-A 4<br>SS M4 D 128-A 4|A.8<br>I.10<br>A.20<br>B.5|
|0103300000|BFSC M4X9T|H.4|0124000000|VL 2 SAK35|B.5|0130800000|QL 4 SAK4|A.38|0136400000|SS M4 D 128-A 4|A.26|
|0103300000|BFSC M4X9T|I.9|0124000000|VL 2 SAK35|A.5|0130800000|QL 4 SAK4|A.37|0136400000|SS M4 D 128-A 4|A.27|
|0105060000|SAK 4 OR|I.7|0124000000|VL 2 SAK35|I.12|0130800000|QL 4 SAK4|I.10|0136400000|SS M4 D 128-A 4|C.4|
|0105100000|AP SAK4-10 DB|I.6|0124000000|VL 2 SAK35|B.8|0130800000|QL 4 SAK4|I.9|0136400000|SS M4 D 128-A 4|B.9|
|0105160000|AP SAK4-10 OR|I.6|0124300000|H16,0/15|J.33|0131700000|AP SAKH6/10 EP/SW|D.7|0136400000|SS M4 D 128-A 4|B.8|
|0105360000|AP ASK1 OR|I.6|0124400000|H25,0/15|J.33|0131700000|AP SAKH6/10 EP/SW|I.6|0136400000|SS M4 D 128-A 4|B.4|
|0105420000|SAKT 1/35/LT|A.32|0124620000|SAKT 1/35/QT2|A.33|0131700000|AP SAKH6/10 EP/SW|D.6|0136400000|SS M4 D 128-A 4|A.9|
|0105620000|SAKT 1/35/LT STB|A.32|0124700000|H6,0/15|J.33|0131720000|AP SAKH6/10 KRG|I.6|0136400000|SS M4 D 128-A 4|A.4|
|0105720000|SAKT 1/35/QT1|A.33|0124800000|H10,0/15|J.33|0131730000|AP SAKH6/10 KRS|I.4|0136400000|SS M4 D 128-A 4|B.24|
|0105820000|SAKT 1/35/DU1|A.32|0126600000|SAKH 6 EP/SW|I.7|0132660010|DEK 5 FW 10-500|K.7|0136400000|SS M4 D 128-A 4|A.5|
|0105920000|SAKT 2/35/LT/STB|A.33|0126600000|SAKH 6 EP/SW|D.6|0132961021|DEK 5 GS A|K.7|0136400000|SS M4 D 128-A 4|B.19|
|0106020000|SAKT 2/35/LT 4STB|A.33|0126700000|SAKH 10 EP/SW|I.7|0132961022|DEK 5 GS B|K.7|0136400000|SS M4 D 128-A 4|B.25|
|0107160000|SAK 2.5/TC AL|B.34|0126700000|SAKH 10 EP/SW|D.7|0132961023|DEK 5 GS C|K.7|0137400000|E 14/2A RS|A.28|
|0107180000|SAK 2.5/TC AL BL|I.7|0128300000|SAK 4 EP/SW|I.7|0132961024|DEK 5 GS D|K.7|0137400000|E 14/2A RS|A.26|
|0107260000|SAK 2.5/TC CH|B.34|0128300000|SAK 4 EP/SW|D.6|0132961025|DEK 5 GS E|K.7|0137400000|E 14/2A RS|B.26|
|0107280000|SAK 2.5/TC CH BL|I.7|0128320000|SAK 4 KRG|B.6|0132961026|DEK 5 GS F|K.7|0137400000|E 14/2A RS|B.24|
|0108520000|SAK 2.5 SW 1X1/KRG|I.7|0128370000|SAK 4 KRG BL|I.7|0132961027|DEK 5 GS G|K.7|0137500000|E 14/4A BR|A.26|
|0108560000|SAK 2.5 SW 1X1|I.7|0128370000|SAK 4 KRG BL|B.6|0132961028|DEK 5 GS H|K.7|0137500000|E 14/4A BR|B.24|
|0108560000|SAK 2.5 SW 1X1|B.38|0128380000|SAK 4 BL|B.3|0132961029|DEK 5 GS I|K.7|0137500000|E 14/4A BR|B.26|
|0108960000|AKZ 2.5 K SW U/V 1X1|E.13|0128380000|SAK 4 BL|I.7|0132961030|DEK 5 GS J|K.7|0137500000|E 14/4A BR|A.28|
||||0128900000|BFSC M3X22 PA/RT|A.7|0132961031|DEK 5 GS K|K.7|0138000000|P 14/2 D01 RS SAKS4|A.26|
|**0110000000**|||0128900000<br>0128900000|BFSC M3X22 PA/RT<br>BFSC M3X22 PA/RT|I.17<br>A.8|0132961032<br>0132961033|DEK 5 GS L<br>DEK 5 GS M|K.7<br>K.7|0138000000<br>0138000000|P 14/2 D01 RS SAKS4<br>P 14/2 D01 RS SAKS4|B.24<br>A.29|
|0110020000|SAK 10 KRG|B.7|0128900000|BFSC M3X22 PA/RT|C.5|0132961034|DEK 5 GS N|K.7|0138000000|P 14/2 D01 RS SAKS4|B.27|
|0110040000|SAK 10 OR|I.7|0128900000|BFSC M3X22 PA/RT|A.9|0132961035|DEK 5 GS O|K.7|0138100000|P 14/4 D01 BR SAKS4|A.29|
|0110060000|SAK 10|B.3|0128900000|BFSC M3X22 PA/RT|A.3|0132961036|DEK 5 GS P|K.7|0138100000|P 14/4 D01 BR SAKS4|B.24|
|0110070000|SAK 10 KRG/BL|I.7|0128900000|BFSC M3X22 PA/RT|B.2|0132961037|DEK 5 GS Q|K.7|0138100000|P 14/4 D01 BR SAKS4|A.26|
|0110070000|SAK 10 KRG/BL|B.7|0128900000|BFSC M3X22 PA/RT|A.40|0132961038|DEK 5 GS R|K.7|0138100000|P 14/4 D01 BR SAKS4|B.27|
|0110080000|SAK 10 BL|B.3|0128900000|BFSC M3X22 PA/RT|C.4|0132961039|DEK 5 GS S|K.7|0139160000|SAK 70/35|A.6|
|0110080000<br>0114100000<br>0114300000|SAK 10 BL<br>QL 2 SAKB10<br>QL 3 SAKB10|I.7<br>B.30<br>B.30|0128900000<br>0128900000<br>0128900000|BFSC M3X22 PA/RT<br>BFSC M3X22 PA/RT<br>BFSC M3X22 PA/RT|B.45<br>B.39<br>A.4|0132961040<br>0132961041<br>0132961042|DEK 5 GS T<br>DEK 5 GS U<br>DEK 5 GS V|K.7<br>K.7<br>K.7|**0140000000**|||
|0114500000|QL 4 SAKB10|B.30|0128900000|BFSC M3X22 PA/RT|B.4|0132961043|DEK 5 GS W|K.7|0140200000|STB 16/D7/4/M4 SAK35|B.5|
|0117500000|TS 15X5/LL 2M/ST/ZN|H.10|0128900000|BFSC M3X22 PA/RT|B.3|0132961044|DEK 5 GS X|K.7|0140200000|STB 16/D7/4/M4 SAK35|A.5|
|0117510000|TS 15X5/LL 1M/ST/ZN|H.10|0128900000|BFSC M3X22 PA/RT|C.3|0132961045|DEK 5 GS Y|K.7|0140200000|STB 16/D7/4/M4 SAK35|I.15|
|0117900000|AP SAK4-10 RT|I.6|0128900000|BFSC M3X22 PA/RT|A.2|0132961046|DEK 5 GS Z|K.7|0140200000|STB 16/D7/4/M4 SAK35|B.4|
|0117910000|AP SAK4-10 I|I.6|0128900000|BFSC M3X22 PA/RT|C.2|0133161114|DEK 5 FW U1-PE1|K.7|0140200000|STB 16/D7/4/M4 SAK35|A.9|
|0117920000|AP SAK4-10 KRG|I.4|0128900000|BFSC M3X22 PA/RT|B.7|0133161115|DEK 5 FW U2-PE2|K.7|0140200000|STB 16/D7/4/M4 SAK35|A.4|
|0117920000|AP SAK4-10 KRG|I.6|0128900000|BFSC M3X22 PA/RT|B.6|0133161116|DEK 5 FW U3-PE3|K.7|0140200000|STB 16/D7/4/M4 SAK35|C.4|
|0117920000|AP SAK4-10 KRG|A.7|0129100000|BFSC M4X32 PA/RT|B.5|0133161117|DEK 5 FW U4-PE4|K.7|0140200000|STB 16/D7/4/M4 SAK35|B.9|
|0117920000|AP SAK4-10 KRG|A.20|0129100000|BFSC M4X32 PA/RT|A.5|0133161118|DEK 5 FW U5-PE5|K.7|0140200000|STB 16/D7/4/M4 SAK35|B.8|
|0117920000|AP SAK4-10 KRG|B.44|0129100000|BFSC M4X32 PA/RT|B.4|0133161119|DEK 5 FW U6-PE6|K.7|0140200000|STB 16/D7/4/M4 SAK35|B.30|
|0117920000|AP SAK4-10 KRG|B.7|0129100000|BFSC M4X32 PA/RT|B.9|0133161120|DEK 5 FW U7-PE7|K.7|0140320000|KS 4 O.D4|F.4|
|0117920000|AP SAK4-10 KRG|B.19|0129100000|BFSC M4X32 PA/RT|A.9|0133161121|DEK 5 FW U8-PE8|K.7|0140500000|D4 KS4 TP|F.4|
|0117920000|AP SAK4-10 KRG|B.6|0129100000|BFSC M4X32 PA/RT|C.4|0133161122|DEK 5 FW U9-PE9|K.7|0140620000|KS 6 O.D6|F.4|
|0117920000|AP SAK4-10 KRG|A.8|0129100000|BFSC M4X32 PA/RT|B.8|0133261150|DEK 5 FW X1-Z1|K.7|0140800000|D6 KS6 TP|F.4|
|0117960000|AP SAK4-10|A.38|0129100000|BFSC M4X32 PA/RT|A.4|0133261151|DEK 5 FW X2-Z2|K.7|0141620000|KS 10 O.D10|F.4|
|0117960000|AP SAK4-10|A.37|0129100000|BFSC M4X32 PA/RT|I.17|0133261152|DEK 5 FW X3-Z3|K.7|0141800000|D10 KS10 TP|F.4|
|0117960000<br>0117960000<br>0117960000|AP SAK4-10<br>AP SAK4-10<br>AP SAK4-10|A.3<br>B.3<br>B.37|**0130000000**|||0133261153<br>0133261154<br>0133261155|DEK 5 FW X4-Z4<br>DEK 5 FW X5-Z5<br>DEK 5 FW X6-Z6|K.7<br>K.7<br>K.7|0142800000<br>0142900000<br>0143000000|ELSO 2 F.KS 2<br>ELSO 4 F.KS 4<br>ELSO 6 F.KS 6|F.4<br>F.4<br>F.4|
|0117960000|AP SAK4-10|B.44|0130000000|STB 7.5/D6/4/M4 ZB/SAKB|I.15|0133261156|DEK 5 FW X7-Z7|K.7|0143100000|ELSO 10 F.KS 10|F.4|
|0117960000|AP SAK4-10|C.2|0130070000||I.10|0133261157|DEK 5 FW X8-Z8|K.7|0143200000|ELSB 2 BEZ. 1-2|F.4|
|0117960000|AP SAK4-10|C.3|0130100000|TW SAK4-10 EP/SW|D.6|0133261158|DEK 5 FW X9-Z9|K.7|0143300000|ELSB 4 BEZ. 1-4|F.4|
|0117960000|AP SAK4-10|C.4|0130120000|TW SAK4-10 KRG|A.8|0133261159|DEK 5 FW X10-Z10|K.7|0143400000|ELSB 6 BEZ. 1-6|F.4|
|0117960000|AP SAK4-10|C.5|0130120000|TW SAK4-10 KRG|B.44|0133360001|DEK 6 FSZ 1-10|K.8|0143500000|ELSB 10 BEZ. 1-10|F.4|
|0117960000|AP SAK4-10|I.6|0130120000|TW SAK4-10 KRG|A.20|0133360011|DEK 6 FSZ 11-20|K.8|0144400000|SAKE 35|B.14|
|0117970000|AP SAK4-10 KRG/BL|B.19|0130120000|TW SAK4-10 KRG|B.6|0133360021|DEK 6 FSZ 21-30|K.8|0146710000|AP SAKB-C-T I|B.19|
|0117970000|AP SAK4-10 KRG/BL|A.8|0130120000|TW SAK4-10 KRG|A.7|0133360031|DEK 6 FSZ 31-40|K.8|0146720000|AP SAKB/C/T KRG|I.6|
|0117970000|AP SAK4-10 KRG/BL|A.7|0130120000|TW SAK4-10 KRG|B.7|0133360041|DEK 6 FSZ 41-50|K.8|0146720000|AP SAKB/C/T KRG|B.32|
|0117970000|AP SAK4-10 KRG/BL|B.44|0130120000|TW SAK4-10 KRG|B.19|0133360051|DEK 6 FSZ 51-60|K.8|0146720000|AP SAKB/C/T KRG|I.4|
|0117970000|AP SAK4-10 KRG/BL|B.7|0130160000|TW 4 SAK4-10|C.4|0133360061|DEK 6 FSZ 61-70|K.8|0146720000|AP SAKB/C/T KRG|A.20|
|0117970000|AP SAK4-10 KRG/BL|I.6|0130160000|TW 4 SAK4-10|C.5|0133360071|DEK 6 FSZ 71-80|K.8|0146720000|AP SAKB/C/T KRG|B.31|
|0117970000|AP SAK4-10 KRG/BL|B.6|0130160000|TW 4 SAK4-10|B.3|0133360081|DEK 6 FSZ 81-90|K.8|0146720000|AP SAKB/C/T KRG|A.32|
|0117970000|AP SAK4-10 KRG/BL|A.20|0130160000|TW 4 SAK4-10|B.37|0133360091|DEK 6 FSZ 91-100|K.8|0146720000|AP SAKB/C/T KRG|A.33|
|0117980000|AP SAK4-10 BL|C.3|0130160000|TW 4 SAK4-10|A.38|0133400000|STB 28.5 IH/SW SAK2.5|I.15|0146720000|AP SAKB/C/T KRG|B.30|
|0117980000|AP SAK4-10 BL|C.5|0130160000|TW 4 SAK4-10|C.2|0134120000|SAKA 10|B.30|0146760000|AP SAKB/C/T BE|I.6|
|0117980000|AP SAK4-10 BL|C.4|0130160000|TW 4 SAK4-10|A.37|0134220000|AP SAKA KRG|B.30|0147100000|STB 17/D6/4/M4 SAKC10|B.19|
|0117980000|AP SAK4-10 BL|C.2|0130160000|TW 4 SAK4-10|A.36|0134220000|AP SAKA KRG|I.6|0147100000|STB 17/D6/4/M4 SAKC10|A.20|
|0117980000|AP SAK4-10 BL|B.3|0130160000|TW 4 SAK4-10|B.44|0134220000|AP SAKA KRG|I.4|0147100000|STB 17/D6/4/M4 SAKC10|D.9|
|0117980000|AP SAK4-10 BL|I.6|0130160000|TW 4 SAK4-10|A.3|0134420000|KS 2 O.D2|F.4|0147100000|STB 17/D6/4/M4 SAKC10|B.29|
|0117980000|AP SAK4-10 BL|A.3|0130160000|TW 4 SAK4-10|C.3|0134500000|D2 KS2 TP|F.4|0147100000|STB 17/D6/4/M4 SAKC10|I.15|
||||0130170000|TW SAK4-10 KRG/BL|A.8|0134700000|TS 15X5 2M/AL/BK|H.10||||
|**0120000000**|||0130170000<br>0130170000|TW SAK4-10 KRG/BL<br>TW SAK4-10 KRG/BL|A.7<br>A.20|0134920000<br>0135200000|SAKB 10<br>STB 13.5/D6/4/M4 SAKA10|B.30<br>B.30|**0150000000**|||
|0122700000|STB 5.5/D3.7/2.3/M3 ZB|I.15|0130170000|TW SAK4-10 KRG/BL|B.19|0135200000|STB 13.5/D6/4/M4 SAKA10|I.15|0150420000|SAKG 70 II/GW|B.50|
|0122800000|TS 32X15 2M/ST/ZN|H.10|0130170000|TW SAK4-10 KRG/BL|B.7|0135500000|QL 2 SAKA10|I.10|0150960000|AP SAKD2.5N|A.2|
|0123600000|QL 2 SAK35|B.8|0130170000|TW SAK4-10 KRG/BL|B.6|0135500000|QL 2 SAKA10|B.19|0150960000|AP SAKD2.5N|I.6|
|0123600000|QL 2 SAK35|I.9|0130170000|TW SAK4-10 KRG/BL|B.44|0135500000|QL 2 SAKA10|A.20|0150960000|AP SAKD2.5N|I.4|
|0123600000|QL 2 SAK35|C.4|0130180000|TW 4 SAK4-10 BL|C.5|0135500000|QL 2 SAKA10|B.30|0150960000|AP SAKD2.5N|B.2|
|0123600000|QL 2 SAK35|B.5|0130180000|TW 4 SAK4-10 BL|C.4|0135600000|QL 3 SAKA10|B.19|0150980000|AP SAKD2.5N BL|I.6|
|0123600000|QL 2 SAK35|B.4|0130180000|TW 4 SAK4-10 BL|A.3|0135600000|QL 3 SAKA10|A.20|0150980000|AP SAKD2.5N BL|A.2|
|0123600000|QL 2 SAK35|A.4|0130180000|TW 4 SAK4-10 BL|C.3|0135600000|QL 3 SAKA10|B.30|0150980000|AP SAKD2.5N BL|B.2|
|0123600000|QL 2 SAK35|A.5|0130180000|TW 4 SAK4-10 BL|C.2|0135700000|QL 4 SAKA10|B.30|0151400000|TW SAKG28 HP/DBR/2|B.47|
|0123700000|QL 3 SAK35|C.4|0130180000|TW 4 SAK4-10 BL|B.3|0135700000|QL 4 SAKA10|B.19|0151400000|TW SAKG28 HP/DBR/2|B.46|
|0123700000|QL 3 SAK35|B.8|0130200000|STB 6/D3.9/2.3/M2.5 ZB|B.6|0135700000|QL 4 SAKA10|A.20|0151400000|TW SAKG28 HP/DBR/2|B.48|
|0123700000|QL 3 SAK35|B.4|0130200000|STB 6/D3.9/2.3/M2.5 ZB|I.15|0135800000|VL 2 SAK16/SAKA|A.4|0151400000|TW SAKG28 HP/DBR/2|A.44|
|0123700000|QL 3 SAK35|A.4|0130600000|QL 2 SAK4|A.38|0135800000|VL 2 SAK16/SAKA|I.12|0151400000|TW SAKG28 HP/DBR/2|B.49|
**X.14**
|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|0151400000|TW SAKG28 HP/DBR/2|A.43|0170520000|SAKG 40 II|B.51|0180400000|PS 2.3 RT|B.10|0193280000|SAK 6N BL|I.7|
|0151400000|TW SAKG28 HP/DBR/2|B.50|0170620000|SAKG 46 II|B.52|0180400000|PS 2.3 RT|B.17|0193280000|SAK 6N BL|B.3|
|0155900000|QL 2 SAK2.5|A.33|0170720000|SAKG 54 II|B.53|0180400000|PS 2.3 RT|A.7|0193400000||I.10|
|0155900000|QL 2 SAK2.5|I.9|0170820000|SAKG 28 III|B.48|0180400000|PS 2.3 RT|E.13|0194000000|QL 2 SAKG32+70|A.44|
|0155900000|QL 2 SAK2.5|B.32|0172160000|SAKR/35|A.18|0180400000|PS 2.3 RT|C.5|0194000000|QL 2 SAKG32+70|B.48|
|0155900000|QL 2 SAK2.5|I.10|0172180000|SAKR/35 BL|I.7|0180400000|PS 2.3 RT|B.11|0194000000|QL 2 SAKG32+70|B.49|
|0156000000|QL 3 SAK2.5|B.32|0172180000|SAKR/35 BL|A.18|0180400000|PS 2.3 RT|E.10|0194000000|QL 2 SAKG32+70|B.50|
|0156000000|QL 3 SAK2.5|I.10|0172190000|SAKR/35 WS|I.7|0180400000|PS 2.3 RT|C.4|0194000000|QL 2 SAKG32+70|A.43|
|0156000000<br>0156000000<br>0156100000<br>0156100000|QL 3 SAK2.5<br>QL 3 SAK2.5<br>QL 4 SAK2.5<br>QL 4 SAK2.5|I.9<br>A.33<br>I.9<br>A.33|0177100000<br>0177100000<br>0177100000<br>0177100000|TW SAKG46 HP/DBR/2<br>TW SAKG46 HP/DBR/2<br>TW SAKG46 HP/DBR/2<br>TW SAKG46 HP/DBR/2|B.52<br>A.42<br>B.49<br>A.43|0180400000<br>0180500000<br>0180500000<br>0180500000|PS 2.3 RT<br>EP 1 SAKG32/35 HP/DBR<br>EP 1 SAKG32/35 HP/DBR<br>EP 1 SAKG32/35 HP/DBR|E.12<br>A.44<br>B.49<br>A.43|0194000000<br>0194100000<br>0194100000<br>0194300000|QL 2 SAKG32+70<br>QL 2 SAKG40<br>QL 2 SAKG40<br>QL 2 SAK6N|A.42<br>B.50<br>B.51<br>A.32|
|0156100000|QL 4 SAK2.5|B.32|0177100000|TW SAKG46 HP/DBR/2|A.47|0180500000|EP 1 SAKG32/35 HP/DBR|I.4|0194300000|QL 2 SAK6N|I.9|
|0156100000|QL 4 SAK2.5|I.10|0177100000|TW SAKG46 HP/DBR/2|B.53|0180600000|EP 1 SAKG32/35 HP/TF/GE|I.4|0194300000|QL 2 SAK6N|I.10|
|0157261187|DEK 5 GS PE|K.7|0177100000|TW SAKG46 HP/DBR/2|B.48|0180600000|EP 1 SAKG32/35 HP/TF/GE|A.44|0194300000|QL 2 SAK6N|A.11|
|0157261202|DEK 5 GS ERDE|K.7|0177100000|TW SAKG46 HP/DBR/2|A.44|0180600000|EP 1 SAKG32/35 HP/TF/GE|A.43|0194300000|QL 2 SAK6N|A.33|
|0157261203|DEK 5 GS ERDE IM KREIS|K.7|0177100000|TW SAKG46 HP/DBR/2|B.50|0180600000|EP 1 SAKG32/35 HP/TF/GE|B.49|0194300000|QL 2 SAK6N|B.32|
|0158760000|AKZ 4 SF SE 6.3/2.8|E.9|0177100000|TW SAKG46 HP/DBR/2|A.46|0180700000|EP 2 SAKG46/35 HP/DBR|A.47|0194300000|QL 2 SAK6N|B.28|
||||0177100000|TW SAKG46 HP/DBR/2|B.51|0180700000|EP 2 SAKG46/35 HP/DBR|A.46|0194300000|QL 2 SAK6N|I.21|
|**0160000000**|||0177100000<br>0177600000|TW SAKG46 HP/DBR/2<br>AP SAK4-10 KRG/DB|A.45<br>I.6|0180700000<br>0180700000|EP 2 SAKG46/35 HP/DBR<br>EP 2 SAKG46/35 HP/DBR|A.45<br>A.44|0194300000<br>0194400000|QL 2 SAK6N<br>QL 3 SAK6N|B.31<br>I.10|
|0162220000|SAKS 4 USA|B.25|0178100000|TSTW 5/M5|H.14|0180700000|EP 2 SAKG46/35 HP/DBR|I.4|0194400000|QL 3 SAK6N|B.28|
|0162520000|AP AKA2.5|I.6|0178220000|SAKS 4/35 USA|A.27|0180700000|EP 2 SAKG46/35 HP/DBR|A.42|0194400000|QL 3 SAK6N|A.32|
|0162520000|AP AKA2.5|E.12|0178500000|AD 3 SAK10|I.17|0180700000|EP 2 SAKG46/35 HP/DBR|A.43|0194400000|QL 3 SAK6N|I.21|
|0162570000|AP AKA2.5 KRG/BL|E.12|0178600000|AD 4 SAK10|C.3|0180800000|EP 2 SAKG46/35 HP/TF/GE|A.44|0194400000|QL 3 SAK6N|A.33|
|0162570000|AP AKA2.5 KRG/BL|I.6|0178600000|AD 4 SAK10|I.17|0180800000|EP 2 SAKG46/35 HP/TF/GE|A.47|0194400000|QL 3 SAK6N|B.32|
|0164000000|TSTW 6/M6|H.14|0178600000|AD 4 SAK10|B.7|0180800000|EP 2 SAKG46/35 HP/TF/GE|A.45|0194400000|QL 3 SAK6N|A.11|
|0164400000|SS M3 D 128-A 3|B.28|0178600000|AD 4 SAK10|A.8|0180800000|EP 2 SAKG46/35 HP/TF/GE|A.46|0194400000|QL 3 SAK6N|I.9|
|0164400000|SS M3 D 128-A 3|A.11|0178600000|AD 4 SAK10|A.3|0180800000|EP 2 SAKG46/35 HP/TF/GE|I.4|0194400000|QL 3 SAK6N|B.31|
|0164400000|SS M3 D 128-A 3|I.10|0178600000|AD 4 SAK10|B.3|0180800000|EP 2 SAKG46/35 HP/TF/GE|A.43|0194500000|QL 4 SAK6N|A.11|
|0164600000|TW SAKG28 HP/TF/GE/2|A.43|0178700000|AD 4 SAK35|C.4|0180800000|EP 2 SAKG46/35 HP/TF/GE|A.42|0194500000|QL 4 SAK6N|I.9|
|0164600000|TW SAKG28 HP/TF/GE/2|A.44|0178700000|AD 4 SAK35|I.17|0181800000|BAL 2|J.11|0194500000|QL 4 SAK6N|A.33|
|0164600000|TW SAKG28 HP/TF/GE/2|B.47|0178700000|AD 4 SAK35|A.9|0182000000|EP 2/BW SAKG46/35 HP/DBR|I.5|0194500000|QL 4 SAK6N|B.28|
|0164600000|TW SAKG28 HP/TF/GE/2|B.50|0178700000|AD 4 SAK35|B.5|0183380000|SAKR/35 2STB BL|I.7|0194500000|QL 4 SAK6N|B.32|
|0164600000|TW SAKG28 HP/TF/GE/2|B.46|0178700000|AD 4 SAK35|A.5|0185020000|SAKG 28 II/GW|B.47|0194500000|QL 4 SAK6N|I.21|
|0164600000|TW SAKG28 HP/TF/GE/2|B.48|0178700000|AD 4 SAK35|A.4|0185120000|SAKG 32 II/GW|B.49|0194500000|QL 4 SAK6N|B.31|
|0164600000|TW SAKG28 HP/TF/GE/2|B.49|0178700000|AD 4 SAK35|B.8|0185220000|SAKG 40 II/GW|B.51|0194500000|QL 4 SAK6N|A.32|
|0165860000|STA 2.5/2|B.43|0179900000|TW SAKG46 HP/TF/GE/2|B.52|0185320000|SAKG 46 II/GW|B.52|0194500000|QL 4 SAK6N|I.10|
|0165860000|STA 2.5/2|A.36|0179900000|TW SAKG46 HP/TF/GE/2|A.42|0185420000|SAKG 54 II/GW|B.53|0194700000|VL 2 SAK6N/SAKT|A.8|
|0165860000|STA 2.5/2|A.37|0179900000|TW SAKG46 HP/TF/GE/2|A.45|0185760000|SAKRD/35|A.18|0194700000|VL 2 SAK6N/SAKT|A.3|
|0165860000|STA 2.5/2|B.42|0179900000|TW SAKG46 HP/TF/GE/2|B.49|0186100000|H2,5/12|J.33|0194700000|VL 2 SAK6N/SAKT|C.3|
|0165860000|STA 2.5/2|B.36|0179900000|TW SAKG46 HP/TF/GE/2|B.48|0186500000|H1,5/10|J.33|0194700000|VL 2 SAK6N/SAKT|B.7|
|0165960000|STA 2.5/3|A.37|0179900000|TW SAKG46 HP/TF/GE/2|A.44|0189860000|SAK 2.5/TC CO|B.34|0194700000|VL 2 SAK6N/SAKT|B.28|
|0165960000|STA 2.5/3|B.36|0179900000|TW SAKG46 HP/TF/GE/2|B.53|0189960000|SAK 2.5/TC CU|B.34|0194700000|VL 2 SAK6N/SAKT|I.12|
|0165960000|STA 2.5/3|B.42|0179900000|TW SAKG46 HP/TF/GE/2|B.50||||0194700000|VL 2 SAK6N/SAKT|A.11|
|0165960000<br>0165960000|STA 2.5/3<br>STA 2.5/3|B.43<br>A.36|0179900000<br>0179900000|TW SAKG46 HP/TF/GE/2<br>TW SAKG46 HP/TF/GE/2|A.47<br>B.51|**0190000000**|||0195620000<br>0196600000|SAKT 1/DU1<br>AD 4 SAK6N|B.31<br>A.8|
|0166060000|STA 2.5/5|B.42|0179900000|TW SAKG46 HP/TF/GE/2|A.46|0190060000|SAK 2.5/TC FE|B.34|0196600000|AD 4 SAK6N|B.3|
|0166060000|STA 2.5/5|B.43|0179900000|TW SAKG46 HP/TF/GE/2|A.43|0190160000|EK 16/35|A.15|0196600000|AD 4 SAK6N|C.3|
|0166060000|STA 2.5/5|B.36||||0190260000|TSCH 6 DKI S4|B.37|0196600000|AD 4 SAK6N|I.17|
|0166060000<br>0166060000|STA 2.5/5<br>STA 2.5/5|A.36<br>A.37|**0180000000**|||0190260000<br>0190260000|TSCH 6 DKI S4<br>TSCH 6 DKI S4|A.38<br>A.39|0196600000<br>0196600000|AD 4 SAK6N<br>AD 4 SAK6N|A.3<br>B.7|
|0166160000|STA 2.5/8|B.42|0180400000|PS 2.3 RT|E.3|0190260000|TSCH 6 DKI S4|B.10|0197000000|VL 2 SAK4|I.12|
|0166160000|STA 2.5/8|A.36|0180400000|PS 2.3 RT|A.2|0190260000|TSCH 6 DKI S4|A.12|0197000000|VL 2 SAK4|C.4|
|0166160000|STA 2.5/8|B.36|0180400000|PS 2.3 RT|E.9|0190260000|TSCH 6 DKI S4|B.11|0197000000|VL 2 SAK4|C.2|
|0166160000|STA 2.5/8|B.43|0180400000|PS 2.3 RT|E.8|0190260000|TSCH 6 DKI S4|A.13|0197000000|VL 2 SAK4|B.6|
|0166160000|STA 2.5/8|A.37|0180400000|PS 2.3 RT|A.54|0190360000|STA 2.5/4|B.42|0197000000|VL 2 SAK4|A.7|
|0166800000|TW AKZ4 HP/DBR/0.5|E.10|0180400000|PS 2.3 RT|B.28|0190360000|STA 2.5/4|B.36|0197000000|VL 2 SAK4|C.5|
|0167000000|QL 3 SAK70|I.9|0180400000|PS 2.3 RT|A.19|0190360000|STA 2.5/4|A.37|0197000000|VL 2 SAK4|B.3|
|0167000000|QL 3 SAK70|B.9|0180400000|PS 2.3 RT|I.14|0190360000|STA 2.5/4|A.36|0197000000|VL 2 SAK4|A.3|
|0167000000|QL 3 SAK70|A.6|0180400000|PS 2.3 RT|A.50|0190360000|STA 2.5/4|B.43|0197200000|BSTO 28/4 BK|F.5|
|0168600000|STB 14/D5/2.3/M3 SAK2.5|A.11|0180400000|PS 2.3 RT|A.51|0191120000|SAKS 1/G25|B.23|0197200000|BSTO 28/4 BK|F.6|
|0168600000|STB 14/D5/2.3/M3 SAK2.5|B.3|0180400000|PS 2.3 RT|A.52|0191220000|SAKS 1/G20|B.22|0197300000|BSTB 28/4 BK U 1-4|F.6|
|0168600000|STB 14/D5/2.3/M3 SAK2.5|B.28|0180400000|PS 2.3 RT|A.53|0191300000|AP SAKS1+3 KRG/DB|I.6|0197300000|BSTB 28/4 BK U 1-4|F.5|
|0168600000|STB 14/D5/2.3/M3 SAK2.5|B.42|0180400000|PS 2.3 RT|A.11|0191320000|AP SAKS1+3 KRG|B.22|0197400000|BSTO 28/6 BK|F.5|
|0168600000|STB 14/D5/2.3/M3 SAK2.5|B.43|0180400000|PS 2.3 RT|B.40|0191320000|AP SAKS1+3 KRG|I.4|0197400000|BSTO 28/6 BK|F.6|
|0168600000|STB 14/D5/2.3/M3 SAK2.5|I.15|0180400000|PS 2.3 RT|A.55|0191320000|AP SAKS1+3 KRG|A.24|0197500000|BSTB 28/6 BK U 1-6|F.6|
|0168600000|STB 14/D5/2.3/M3 SAK2.5|B.6|0180400000|PS 2.3 RT|A.56|0191320000|AP SAKS1+3 KRG|B.23|0197500000|BSTB 28/6 BK U 1-6|F.5|
|0168600000|STB 14/D5/2.3/M3 SAK2.5|D.6|0180400000|PS 2.3 RT|B.45|0191320000|AP SAKS1+3 KRG|A.25|0197920000|SAKT E/35 2LD 60VAC|A.57|
|0168600000|STB 14/D5/2.3/M3 SAK2.5|C.5|0180400000|PS 2.3 RT|B.43|0191320000|AP SAKS1+3 KRG|I.6|0198020000|SAKT E/35 2GL 115VAC|A.57|
|0168600000|STB 14/D5/2.3/M3 SAK2.5|A.36|0180400000|PS 2.3 RT|B.42|0191400000|QL 2 SAKS1|A.24|0198120000|SAKT E/35 2GL 230VAC|A.57|
|0168600000|STB 14/D5/2.3/M3 SAK2.5|A.37|0180400000|PS 2.3 RT|B.41|0191400000|QL 2 SAKS1|I.9|0198220000|SAKT E/35 2LD 120VAC|A.57|
|0168600000|STB 14/D5/2.3/M3 SAK2.5|B.36|0180400000|PS 2.3 RT|A.18|0191400000|QL 2 SAKS1|A.25|0198620000|SAKS 1/35 G25 GL 230VAC|A.25|
|0168600000|STB 14/D5/2.3/M3 SAK2.5|A.7|0180400000|PS 2.3 RT|A.38|0191400000|QL 2 SAKS1|B.23|0198700000|BSTO 28/12 BK|F.5|
|0168600000|STB 14/D5/2.3/M3 SAK2.5|A.3|0180400000|PS 2.3 RT|B.19|0191400000|QL 2 SAKS1|B.22|0198700000|BSTO 28/12 BK|F.6|
|0168600000|STB 14/D5/2.3/M3 SAK2.5|C.4|0180400000|PS 2.3 RT|B.56|0191500000|QL 3 SAKS1|A.24|0198800000|BSTB 28/12 BK U 1-12|F.5|
|0168600000|STB 14/D5/2.3/M3 SAK2.5|C.2|0180400000|PS 2.3 RT|A.13|0191500000|QL 3 SAKS1|B.22|0198800000|BSTB 28/12 BK U 1-12|F.6|
|0168800000|SAK 4 CUN/EP/SW|D.6|0180400000|PS 2.3 RT|B.57|0191500000|QL 3 SAKS1|I.9|0199360000|EWK 2|H.13|
|0169300000|TS 32X15 2M/AL/BK|H.10|0180400000|PS 2.3 RT|E.2|0191500000|QL 3 SAKS1|B.23|0199700000|BFSC M3X7 STV1/5|I.9|
|0169900000|STB 14/D6/4/M3 SAK10|B.32|0180400000|PS 2.3 RT|B.2|0191500000|QL 3 SAKS1|A.25|0199920000|SAKS 1/35 G20 GL 230VAC|A.24|
|0169900000|STB 14/D6/4/M3 SAK10|A.3|0180400000|PS 2.3 RT|E.11|0191600000|QL 4 SAKS1|A.25||||
|0169900000<br>0169900000|STB 14/D6/4/M3 SAK10<br>STB 14/D6/4/M3 SAK10|A.9<br>B.3|0180400000<br>0180400000|PS 2.3 RT<br>PS 2.3 RT|B.59<br>B.6|0191600000<br>0191600000|QL 4 SAKS1<br>QL 4 SAKS1|A.24<br>B.23|**0200000000**|||
|0169900000|STB 14/D6/4/M3 SAK10|B.4|0180400000|PS 2.3 RT|A.40|0191600000|QL 4 SAKS1|I.9|0203500000|BSTO 28/2 BK|F.5|
|0169900000|STB 14/D6/4/M3 SAK10|B.7|0180400000|PS 2.3 RT|B.18|0191600000|QL 4 SAKS1|B.22|0203500000|BSTO 28/2 BK|F.6|
|0169900000|STB 14/D6/4/M3 SAK10|A.33|0180400000|PS 2.3 RT|A.39|0191860000|TW SAKD2.5N|A.2|0203600000|BSTB 28/2 BK U 1-2|F.5|
|0169900000|STB 14/D6/4/M3 SAK10|A.8|0180400000|PS 2.3 RT|B.58|0191860000|TW SAKD2.5N|B.2|0203600000|BSTB 28/2 BK U 1-2|F.6|
|0169900000|STB 14/D6/4/M3 SAK10|I.20|0180400000|PS 2.3 RT|B.60|0191880000|TW SAKD2.5N BL|B.2|0203700000|BSTO 28/3 BK|F.6|
|0169900000|STB 14/D6/4/M3 SAK10|A.4|0180400000|PS 2.3 RT|A.36|0191880000|TW SAKD2.5N BL|A.2|0203700000|BSTO 28/3 BK|F.5|
|0169900000|STB 14/D6/4/M3 SAK10|A.32|0180400000|PS 2.3 RT|A.37|0191900000|H6,0/12|J.33|0205100000|EP 1 SAKG28/32 HP/DBR|B.50|
|0169900000|STB 14/D6/4/M3 SAK10|C.3|0180400000|PS 2.3 RT|B.39|0192700000|G 25/2.00A/F BL|A.28|0205100000|EP 1 SAKG28/32 HP/DBR|B.47|
|0169900000|STB 14/D6/4/M3 SAK10|B.28|0180400000|PS 2.3 RT|B.38|0192700000|G 25/2.00A/F BL|B.26|0205100000|EP 1 SAKG28/32 HP/DBR|I.4|
|0169900000|STB 14/D6/4/M3 SAK10|I.15|0180400000|PS 2.3 RT|B.37|0192800000|G 25/4.00A/F BR|A.28|0205100000|EP 1 SAKG28/32 HP/DBR|B.48|
|0169900000|STB 14/D6/4/M3 SAK10|B.31|0180400000|PS 2.3 RT|A.20|0192800000|G 25/4.00A/F BR|B.26|0205100000|EP 1 SAKG28/32 HP/DBR|B.49|
||||0180400000|PS 2.3 RT|B.36|0192900000|G 25/6.30A/F GN|A.28|0205100000|EP 1 SAKG28/32 HP/DBR|B.46|
|**0170000000**|||0180400000<br>0180400000|PS 2.3 RT<br>PS 2.3 RT|B.61<br>A.12|0192900000<br>0193100000|G 25/6.30A/F GN<br>G 25/10.0A/M RT|B.26<br>B.26|0205200000<br>0205200000|EP 1 SAKG28/32 HP/TF/GE<br>EP 1 SAKG28/32 HP/TF/GE|B.46<br>B.47|
|0170020000|SAKG 28 I|B.46|0180400000|PS 2.3 RT|B.32|0193100000|G 25/10.0A/M RT|A.28|0205200000|EP 1 SAKG28/32 HP/TF/GE|B.48|
|0170320000|SAKG 28 II|B.47|0180400000|PS 2.3 RT|C.2|0193220000|SAK 6N KRG|B.7|0205200000|EP 1 SAKG28/32 HP/TF/GE|B.49|
|0170420000|SAKG 32 II|B.49|0180400000|PS 2.3 RT|B.16|0193260000|SAK 6N|B.3|0205200000|EP 1 SAKG28/32 HP/TF/GE|B.50|
**X**
**X.15**
**X**
|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|0205200000|EP 1 SAKG28/32 HP/TF/GE|I.4|0212880000|SAK 6/EN BL|C.3|0245800000|BSTO 28/12 MK|F.6|0267100000|BFSC M4X30|A.5|
|0205300000|EP 2 SAKG46/32 HP/DBR|B.52|0213200000|SAKE 70/32|B.15|0245900000|BSTB 28/12 MK U 1-12|F.6|0267100000|BFSC M4X30|I.10|
|0205300000|EP 2 SAKG46/32 HP/DBR|B.51|0214020000|SAKS 1/35 G20 LD 48VAC|A.24|0245900000|BSTB 28/12 MK U 1-12|F.2|0267100000|BFSC M4X30|H.4|
|0205300000|EP 2 SAKG46/32 HP/DBR|B.49|0215560000|SAKD 2.5N|B.2|0247000000|QL 2 SAKG46|A.47|0267100000|BFSC M4X30|B.5|
|0205300000|EP 2 SAKG46/32 HP/DBR|B.48|0215580000|SAKD 2.5N BL|B.2|0247000000|QL 2 SAKG46|B.52|0267100000|BFSC M4X30|A.4|
|0205300000|EP 2 SAKG46/32 HP/DBR|B.53|0215580000|SAKD 2.5N BL|I.7|0247000000|QL 2 SAKG46|A.46|0267100000|BFSC M4X30|B.9|
|0205300000|EP 2 SAKG46/32 HP/DBR|I.4|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|A.2|0247400000|QL 4 SAKG54|B.53|0267100000|BFSC M4X30|B.4|
|0205300000|EP 2 SAKG46/32 HP/DBR|B.50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|B.2|0247400000|QL 4 SAKG54|A.47|0267200000|STB 25 IH/GE|I.20|
|0205400000|EP 2 SAKG46/32 HP/TF/GE|B.50|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|A.13|0248500000|VH 13.5/4.9/3.3 SAK4|A.11|0267200000|STB 25 IH/GE|I.15|
|0205400000<br>0205400000<br>0205400000|EP 2 SAKG46/32 HP/TF/GE<br>EP 2 SAKG46/32 HP/TF/GE<br>EP 2 SAKG46/32 HP/TF/GE|B.49<br>B.51<br>B.52|0215700000<br>0215700000<br>0215700000|STB 8.5/D4/2.3/M2.5 AKZ<br>STB 8.5/D4/2.3/M2.5 AKZ<br>STB 8.5/D4/2.3/M2.5 AKZ|B.11<br>B.10<br>B.59|0248500000<br>0248500000<br>0248500000|VH 13.5/4.9/3.3 SAK4<br>VH 13.5/4.9/3.3 SAK4<br>VH 13.5/4.9/3.3 SAK4|I.9<br>I.10<br>B.28|0267400000<br>0267400000<br>0267500000|QL 2 RSF1+2<br>QL 2 RSF1+2<br>QL 3 RSF1+2|B.29<br>B.28<br>B.28|
|0205400000|EP 2 SAKG46/32 HP/TF/GE|B.48|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|E.9|0248920000|SAKS 3 GZ/6.3X32|B.23|0267500000|QL 3 RSF1+2|B.29|
|0205400000|EP 2 SAKG46/32 HP/TF/GE|B.53|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|A.53|0249000000|VH 12/4.9/3.3 SAK6N|B.32|0267600000|QL 4 RSF1+2|B.29|
|0205400000|EP 2 SAKG46/32 HP/TF/GE|I.4|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|E.10|0249000000|VH 12/4.9/3.3 SAK6N|B.31|0267600000|QL 4 RSF1+2|B.28|
|0205700000|QB 2 SAKT1|I.21|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|B.60|0249000000|VH 12/4.9/3.3 SAK6N|I.10|0268860000|SAKD 2.5/35|A.2|
|0205800000|QB 3 SAKT1|I.21|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|I.15|0249000000|VH 12/4.9/3.3 SAK6N|A.32|0268880000|SAKD 2.5/35 BL|I.7|
|0205900000|QB 4 SAKT1|I.21|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|A.52|0249000000|VH 12/4.9/3.3 SAK6N|I.21|0268880000|SAKD 2.5/35 BL|A.2|
|0206160000|EWK 1|H.13|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|E.3|0249000000|VH 12/4.9/3.3 SAK6N|I.9|0269120000|SAKT 1/LT|B.31|
|0206160000|EWK 1|B.62|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|A.39|0249000000|VH 12/4.9/3.3 SAK6N|A.33|0269320000|SAKT 1/QT1|B.31|
|0206160000|EWK 1|C.8|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|A.50|0249000000|VH 12/4.9/3.3 SAK6N|I.9||||
|0206820000<br>0207400000|SAKS 2<br>QL 2 SAK6N-SAK35|B.24<br>I.10|0215700000<br>0215700000|STB 8.5/D4/2.3/M2.5 AKZ<br>STB 8.5/D4/2.3/M2.5 AKZ|A.51<br>A.38|0249100000<br>0249200000|KMVF LI 6.3 EP/SW<br>KMVF RE 6.3 EP/SW|D.8<br>D.8|**0270000000**|||
|0207530000|DS 14 SAK4|I.12|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|E.11|0249300000|KMVT LI 2.4 EP/SW|D.9|0270100000|TS 35X15/2.3 2M/CU/BK|H.11|
|0207630000|DS 12.5 SAK10|I.12|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|B.38|0249400000|KMVT RE 2.4 EP/SW|D.9|0270320000|RSF 1 KRG|B.28|
|0207730000|DS 12.5 SAK6N|I.12|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|B.37|0249600000|ZS 2.3/4|I.14|0270420000|AP RSF1 KRG|I.6|
|0207800000|QL 2 SAKS2|A.26|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|A.54||||0270460000|AP RSF3|I.6|
|0207800000<br>0207800000|QL 2 SAKS2<br>QL 2 SAKS2|I.9<br>B.25|0215700000<br>0215700000|STB 8.5/D4/2.3/M2.5 AKZ<br>STB 8.5/D4/2.3/M2.5 AKZ|E.12<br>A.56|**0250000000**|||0270460000<br>0270460000|AP RSF3<br>AP RSF3|A.11<br>B.28|
|0207800000|QL 2 SAKS2|A.27|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|E.2|0254120000|SAKT 4/LT O.STB|B.32|0270760000|QS 2/12/4|I.13|
|0207800000|QL 2 SAKS2|B.24|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|E.8|0257120000|TW SAK2.5-35/32 KRG|B.30|0270760000|QS 2/12/4|I.21|
|0207900000|QL 3 SAKS2|A.26|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|E.13|0258260000|HP 7 TSK31.5|I.16|0270860000|QS 2/10/4|I.13|
|0207900000|QL 3 SAKS2|B.24|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|B.61|0258360000|HP 8 ADP 1|I.16|0270860000|QS 2/10/4|I.21|
|0207900000|QL 3 SAKS2|A.27|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|B.56|0258660000|EW 35/SCHA/M3|I.12|0270960000|QS 2/8/4|A.32|
|0207900000|QL 3 SAKS2|B.25|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|B.57|0258760000|EWK 2/SCHA/M3/L|I.12|0270960000|QS 2/8/4|A.33|
|0207900000|QL 3 SAKS2|I.9|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|B.58|0259800000|SSCH 10X3X1000 MS/BK|H.3|0270960000|QS 2/8/4|I.13|
|0208000000|QL 4 SAKS2|A.27|0215700000|STB 8.5/D4/2.3/M2.5 AKZ|A.12||||0270960000|QS 2/8/4|B.32|
|0208000000<br>0208000000|QL 4 SAKS2<br>QL 4 SAKS2|A.26<br>I.9|0215700000<br>0217160000|STB 8.5/D4/2.3/M2.5 AKZ<br>DK 4SS/35 FF 4X6.3/2.8|A.55<br>A.38|**0260000000**|||0270960000<br>0270960000|QS 2/8/4<br>QS 2/8/4|B.31<br>I.21|
|0208000000|QL 4 SAKS2|B.24|0217900000|TS 15X5/LL 2M/AL/BK|H.10|0261100000|AD 4 WSD SAKG54 HP/DBR|I.17|0271020000|SAK 16 KRG|B.7|
|0208000000|QL 4 SAKS2|B.25|0218660000|SAK 2.5/EN|C.2|0262100000|BSTO 28/16 MK 4/16|F.3|0271060000|SAK 16|B.4|
|0208500000|E 16/10A RT TNDZ|A.26|0218680000|SAK 2.5/EN BL|I.7|0262200000|BSTB 28/16 MK U 1-16|F.3|0271080000|SAK 16 BL|I.7|
|0208500000|E 16/10A RT TNDZ|B.24|0218680000|SAK 2.5/EN BL|C.2|0263100000|AD 4 WSD SAKG28 HP/DBR|I.17|0271080000|SAK 16 BL|B.4|
|0208500000|E 16/10A RT TNDZ|A.28||||0263200000|AD 4 WSD SAKG40 HP/DBR|I.17|0271120000|AP SAK16 KRG|I.6|
|0208500000<br>0208600000|E 16/10A RT TNDZ<br>E 16/16A GR TNDZ|B.26<br>A.28|**0220000000**|||0263300000<br>0263500000|AD 4 WSD SAKG46 HP/DBR<br>QL 3 SAKG40|I.17<br>B.50|0271120000<br>0271120000|AP SAK16 KRG<br>AP SAK16 KRG|B.7<br>A.9|
|0208600000|E 16/16A GR TNDZ|A.26|0220500000|QL 5 SAK6N|I.21|0263500000|QL 3 SAKG40|B.51|0271120000|AP SAK16 KRG|I.4|
|0208600000|E 16/16A GR TNDZ|B.26|0220600000|QL 6 SAK6N|I.21|0264400000|QL 2 SAKG54|A.47|0271160000|AP SAK16|I.4|
|0208600000|E 16/16A GR TNDZ|B.24|0221200000|QL 15 SAK6N|I.21|0264400000|QL 2 SAKG54|B.53|0271160000|AP SAK16|I.6|
|0208700000|E 16/20A BL TNDZ|B.24|0222760000|ASK 1/EN LD 15K 24VDC|C.7|0264900000|AD 3 WSD SAKG54 HP/DBR|I.17|0271160000|AP SAK16|B.4|
|0208700000|E 16/20A BL TNDZ|A.28|0222860000|ASK 1/EN LD 1D 24VAC|C.7|0265800000|G 25/1.00A/M RT|B.26|0271160000|AP SAK16|A.4|
|0208700000|E 16/20A BL TNDZ|A.26|0225260000|ASK 1/EN LD 27K 48VDC|C.7|0265800000|G 25/1.00A/M RT|A.28|0271160000|AP SAK16|C.3|
|0208700000|E 16/20A BL TNDZ|B.26|0225360000|ASK 1/EN LD 1D 48VAC|C.7|0266320000|AST 1 6.3 KRG|B.42|0271180000|AP SAK16 BL|C.3|
|0208800000|E 16/25A GE TNDZ|B.24|0225460000|ASK 1/EN LD 56K 115VDC|C.7|0266360000|AST 1 6.3|B.36|0271180000|AP SAK16 BL|I.6|
|0208800000|E 16/25A GE TNDZ|A.26|0225560000|ASK 1/EN LD 1D 115VAC|C.7|0266400000|AP AST1+5 DB|B.36|0271180000|AP SAK16 BL|A.4|
|0208800000|E 16/25A GE TNDZ|B.26|0225660000|ASK 1/EN LD 120K 230VDC|C.7|0266400000|AP AST1+5 DB|A.37|0271180000|AP SAK16 BL|B.4|
|0208800000|E 16/25A GE TNDZ|A.28|0225760000|ASK 1/EN LD 1D 230VAC|C.7|0266400000|AP AST1+5 DB|A.36|0271200000|STB 25 IH/GN|I.20|
|0208900000|P 16/10 RT SAKS2|B.24|0225820000|SAKS 1/35 G20 LD 24VDC|A.24|0266400000|AP AST1+5 DB|I.6|0271200000|STB 25 IH/GN|I.15|
|0208900000|P 16/10 RT SAKS2|B.27|0226460000|ASK 1/EN LD 33K 60VDC|C.7|0266420000|AP AST1+5 KRG|I.6|0271300000|STB 25 IH/VI|I.20|
|0208900000|P 16/10 RT SAKS2|A.29||||0266420000|AP AST1+5 KRG|I.4|0271300000|STB 25 IH/VI|I.15|
|0208900000<br>0209000000|P 16/10 RT SAKS2<br>P 16/16 GR SAKS2|A.26<br>A.26|**0230000000**|||0266420000<br>0266420000|AP AST1+5 KRG<br>AP AST1+5 KRG|B.43<br>B.42|0271400000<br>0271400000|STB 25 IH/GR<br>STB 25 IH/GR|I.15<br>I.20|
|0209000000|P 16/16 GR SAKS2|A.29|0235000000|IS 8 DIN 6911|J.20|0266460000|AP AST1+5|I.6|0271500000|STB 25 IH/SW|I.15|
|0209000000|P 16/16 GR SAKS2|B.24|0235860000|DEK 5 FWZ 1,3,5-19|K.7|0266500000|ZB 35/M6X16|A.30|0271500000|STB 25 IH/SW|I.20|
|0209000000|P 16/16 GR SAKS2|B.27|0235960000|DEK 5 FWZ 21,23,25-39|K.7|0266500000|ZB 35/M6X16|A.31|0271800000|EP 1/BW SAKG28/32 HP/DB|I.5|
|0209100000|P 16/20 BL SAKS2|B.27|0236060000|DEK 5 FWZ 41,43,45-59|K.7|0266500000|ZB 35/M6X16|H.6|0271900000|EP 2/BW SAKG46/32 HP/DB|I.5|
|0209100000|P 16/20 BL SAKS2|B.24|0236160000|DEK 5 FWZ 2,4,6-20|K.7|0266700000|VH 8/4.9/3.3 SAK2.5|I.10|0273400000|AD 3 SAK35|B.4|
|0209100000|P 16/20 BL SAKS2|A.26|0236260000|DEK 5 FWZ 22,24,26-40|K.7|0266700000|VH 8/4.9/3.3 SAK2.5|B.32|0273400000|AD 3 SAK35|I.17|
|0209100000|P 16/20 BL SAKS2|A.29|0236360000|DEK 5 FWZ 42,44,46-60|K.7|0266700000|VH 8/4.9/3.3 SAK2.5|A.33|0273820000|MK 3/2|F.2|
||||0236400000|TS 35X15 2M/ST/ZN|H.11|0266700000|VH 8/4.9/3.3 SAK2.5|I.9|0273920000|MK 3/3|F.2|
|**0210000000**|||0236500000<br>0236510000|TS 35X15/LL 2M/ST/ZN<br>TS 35X15/LL 1M/ST/ZN|H.11<br>H.11|0266800000<br>0266800000|BFSC M2.5X14 SAKD2.5N<br>BFSC M2.5X14 SAKD2.5N|E.12<br>A.56|0274020000<br>0274120000|MK 3/4<br>MK 3/5|F.2<br>F.2|
|0210060000|DK 4/35 LD GR 24VDC|A.51|0236760000|AST 3 6.3|B.36|0266800000|BFSC M2.5X14 SAKD2.5N|A.55|0274220000|MK 3/6|F.2|
|0210160000|DK 4/32 LD ROT 24VDC|B.57||||0266800000|BFSC M2.5X14 SAKD2.5N|E.11|0274320000|MK 3/7|F.2|
|0210260000<br>0210460000|DK 4/35 LD ROT 24VDC<br>DK 4/35 LD GR 24VDC|A.51<br>A.51|**0240000000**|||0266800000<br>0266800000|BFSC M2.5X14 SAKD2.5N<br>BFSC M2.5X14 SAKD2.5N|E.10<br>A.53|0274420000<br>0274520000|MK 3/8<br>MK 3/9|F.2<br>F.2|
|0210800000|ADL|I.18|0240600000|ZU 1|I.5|0266800000|BFSC M2.5X14 SAKD2.5N|B.56|0274620000|MK 3/10|F.2|
|0211200000|AKE 4 MS|E.4|0241260000|MK 2/12|F.2|0266800000|BFSC M2.5X14 SAKD2.5N|B.59|0278500000|BSTB 28/12/6,35 O 1-12|F.2|
|0211320000|AP SAKR KRG|B.18|0241760000|MF 2/12 1X2.8/1.6|F.2|0266800000|BFSC M2.5X14 SAKD2.5N|B.58|0278700000|BSTB 28/16 MK O 1-16|F.3|
|0211320000|AP SAKR KRG|I.6|0242920000|TW SAKB-C-T|B.30|0266800000|BFSC M2.5X14 SAKD2.5N|A.52|0279500000|AP SAK2.5 GE|I.6|
|0211360000|AP SAKR BE|A.18|0242920000|TW SAKB-C-T|A.20|0266800000|BFSC M2.5X14 SAKD2.5N|A.51|0279520000|AP SAK2.5 KRG|I.6|
|0211360000|AP SAKR BE|B.16|0242920000|TW SAKB-C-T|B.19|0266800000|BFSC M2.5X14 SAKD2.5N|A.50|0279520000|AP SAK2.5 KRG|B.6|
|0211360000|AP SAKR BE|I.4|0242960000|TW SAKB/C/T1|A.20|0266800000|BFSC M2.5X14 SAKD2.5N|B.57|0279520000|AP SAK2.5 KRG|I.4|
|0211360000|AP SAKR BE|I.6|0242960000|TW SAKB/C/T1|B.32|0266800000|BFSC M2.5X14 SAKD2.5N|B.60|0279520000|AP SAK2.5 KRG|A.7|
|0211360000|AP SAKR BE|B.39|0242960000|TW SAKB/C/T1|A.32|0266800000|BFSC M2.5X14 SAKD2.5N|A.54|0279530000|AP SAK2.5 KRS|I.4|
|0211360000|AP SAKR BE|E.3|0242960000|TW SAKB/C/T1|A.33|0267000000|VH 17/8/5 SAK35|A.9|0279540000|AP SAK2.5 OR|I.6|
|0211360000|AP SAKR BE|B.41|0242960000|TW SAKB/C/T1|B.31|0267000000|VH 17/8/5 SAK35|B.4|0279560000|AP SAK2.5|A.2|
|0211360000|AP SAKR BE|B.40|0243520000|MK 3/12|F.2|0267000000|VH 17/8/5 SAK35|I.10|0279560000|AP SAK2.5|B.38|
|0211380000|AP SAKR BL|I.6|0243820000|MK 5/2 O.DE|F.4|0267000000|VH 17/8/5 SAK35|B.9|0279560000|AP SAK2.5|B.39|
|0211380000|AP SAKR BL|B.40|0244060000|D 2 MK5/2 PA/NA|F.4|0267000000|VH 17/8/5 SAK35|A.5|0279560000|AP SAK2.5|A.40|
|0211380000|AP SAKR BL|B.41|0244100000|H4,0/12|J.33|0267000000|VH 17/8/5 SAK35|B.5|0279560000|AP SAK2.5|I.6|
|0211380000|AP SAKR BL|B.16|0244220000|MK 4/16|F.3|0267000000|VH 17/8/5 SAK35|A.4|0279560000|AP SAK2.5|B.34|
|0211380000|AP SAKR BL|A.18|0244600000|STB 8.5/D4.5/2/M3 SAKT4|I.15|0267000000|VH 17/8/5 SAK35|C.4|0279560000|AP SAK2.5|B.2|
|0211400000|QL 2 SAKG40/35|A.45|0244600000|STB 8.5/D4.5/2/M3 SAKT4|A.33|0267000000|VH 17/8/5 SAK35|B.8|0279570000|AP SAK2.5 KRG BL|A.7|
|0212260000|AP TAL|I.6|0244920000|AP SAKT4 KRG|I.6|0267000000|VH 17/8/5 SAK35|I.9|0279570000|AP SAK2.5 KRG BL|I.6|
|0212700000|QS 2/6.5/2.3 SAK4|I.13|0245400000|GZ 12,5A/FF|B.26|0267100000|BFSC M4X30|A.9|0279570000|AP SAK2.5 KRG BL|B.6|
|0212810000|SAK 6/EN SW|I.7|0245400000|GZ 12,5A/FF|A.28|0267100000|BFSC M4X30|C.4|0279580000|AP SAK2.5 BL|I.6|
|0212840000|SAK 6/EN RT|I.7|0245600000|BSTO 28/12/6,35|F.2|0267100000|BFSC M4X30|B.30|0279580000|AP SAK2.5 BL|B.39|
|0212860000|SAK 6/EN|C.3|0245700000|BSTB 28/12/6,35 U 1-12|F.2|0267100000|BFSC M4X30|I.9|0279580000|AP SAK2.5 BL|B.2|
|0212880000|SAK 6/EN BL|I.7|0245800000|BSTO 28/12 MK|F.2|0267100000|BFSC M4X30|B.8|0279580000|AP SAK2.5 BL|A.2|
**X.16**
|**Order No.**<br>**Type**<br>**Page**<br>0279580000 AP SAK2.5 BL<br>A.40<br>0279620000 SAK 2.5 KRG<br>B.6<br>0279660000 SAK 2.5<br>B.2<br>0279670000 SAK 2.5 KRG/BL<br>I.7<br>0279670000 SAK 2.5 KRG/BL<br>B.6<br>0279680000 SAK 2.5 BL<br>I.7<br>0279680000 SAK 2.5 BL<br>B.2<br>**0280000000**<br>0280100000 DKSUE NSCH/ESCH<br>H.3<br>0280200000 NSCH 1M<br>H.3<br>0280300000 ESCH 1 M<br>H.3<br>0280600000 STB 8.5/5/2.3/M3 SAK2.5<br>B.32<br>0280600000 STB 8.5/5/2.3/M3 SAK2.5<br>B.38<br>0280600000 STB 8.5/5/2.3/M3 SAK2.5<br>B.39<br>0280600000 STB 8.5/5/2.3/M3 SAK2.5<br>C.2<br>0280600000 STB 8.5/5/2.3/M3 SAK2.5<br>A.2<br>0280600000 STB 8.5/5/2.3/M3 SAK2.5<br>I.15<br>0280600000 STB 8.5/5/2.3/M3 SAK2.5<br>B.2<br>0280600000 STB 8.5/5/2.3/M3 SAK2.5<br>B.45<br>0280600000 STB 8.5/5/2.3/M3 SAK2.5<br>A.40<br>0280600000 STB 8.5/5/2.3/M3 SAK2.5<br>A.7<br>0281120000 TW SAK16 KRG<br>B.7<br>0281120000 TW SAK16 KRG<br>A.9<br>0282600000 H0,5/6<br>J.33<br>0282700000 H0,75/6<br>J.33<br>0282800000 H1,0/10<br>J.33<br>0282900000 H10,0/12<br>J.33<br>0283100000 AD 4 WSD SAKG32 HP/DBR<br>I.17<br>0284110000 SK E16/SAKS2<br>A.26<br>0284110000 SK E16/SAKS2<br>B.24<br>0284700000 BSTO 28/8 MK3/8<br>F.6<br>0284700000 BSTO 28/8 MK3/8<br>F.2<br>0285100000 VH 19/5/3.5 SAK4-16<br>B.6<br>0285100000 VH 19/5/3.5 SAK4-16<br>B.3<br>0285100000 VH 19/5/3.5 SAK4-16<br>B.7<br>0285100000 VH 19/5/3.5 SAK4-16<br>A.4<br>0285100000 VH 19/5/3.5 SAK4-16<br>B.4<br>0285100000 VH 19/5/3.5 SAK4-16<br>A.3<br>0285100000 VH 19/5/3.5 SAK4-16<br>C.5<br>0285100000 VH 19/5/3.5 SAK4-16<br>A.8<br>0285100000 VH 19/5/3.5 SAK4-16<br>C.2<br>0285100000 VH 19/5/3.5 SAK4-16<br>I.12<br>0285100000 VH 19/5/3.5 SAK4-16<br>C.3<br>0285100000 VH 19/5/3.5 SAK4-16<br>A.7<br>0285100000 VH 19/5/3.5 SAK4-16<br>C.4<br>0285100000 VH 19/5/3.5 SAK4-16<br>A.9<br>0285300000 AD 4 SAK4<br>C.4<br>0285300000 AD 4 SAK4<br>A.3<br>0285300000 AD 4 SAK4<br>B.3<br>0285300000 AD 4 SAK4<br>B.6<br>0285300000 AD 4 SAK4<br>C.5<br>0285300000 AD 4 SAK4<br>I.17<br>0285300000 AD 4 SAK4<br>A.7<br>0285300000 AD 4 SAK4<br>C.2<br>0286400000 DSTV VH 6.5<br>I.10<br>0286620000 SAKG 32 I<br>B.48<br>0286720000 SAKG 32 III<br>B.49<br>0286820000 SAKG 40 I<br>B.50<br>0286920000 SAKG 40 III<br>B.51<br>0289300000 BSTO 28/4 MK3/4<br>F.6<br>0289300000 BSTO 28/4 MK3/4<br>F.2<br>0289500000 BSTO 28/6 MK<br>F.2<br>0289500000 BSTO 28/6 MK<br>F.6<br>**0290000000**<br>0290000000 BSTB 28/6 MK U 1-6<br>F.6<br>0290000000 BSTB 28/6 MK U 1-6<br>F.2<br>0290200000 BSTB 28/8 MK U 1-8<br>F.2<br>0290200000 BSTB 28/8 MK U 1-8<br>F.6<br>0292460000 SCHT 5<br>K.17<br>0292500000 BFSC M3X25<br>A.3<br>0292500000 BFSC M3X25<br>C.2<br>0292500000 BFSC M3X25<br>C.3<br>0292500000 BFSC M3X25<br>A.7<br>0292500000 BFSC M3X25<br>I.12<br>0292500000 BFSC M3X25<br>C.4<br>0292500000 BFSC M3X25<br>A.8<br>0292500000 BFSC M3X25<br>A.9<br>0292500000 BFSC M3X25<br>I.10<br>0292500000 BFSC M3X25<br>C.5<br>0292500000 BFSC M3X25<br>B.7<br>0292500000 BFSC M3X25<br>A.4<br>0292500000 BFSC M3X25<br>B.6<br>0292500000 BFSC M3X25<br>B.3<br>0292500000 BFSC M3X25<br>B.4<br>0293220000 TS 32X15 2M/CRN<br>H.10<br>0293800000 PS 2.0 OR<br>I.14<br>0293800000 PS 2.0 OR<br>A.33<br>0293900000 GZ 10.0A<br>B.26<br>0293900000 GZ 10.0A<br>A.28<br>0294000000 STR 5 F.SCHT 5<br>K.17<br>0294260000 SAKR LL 2STB<br>B.41<br>0294360000 AKZ 4<br>E.3<br>0294380000 AKZ 4 BL<br>E.3<br>0294420000 AP AKZ4 KRG<br>I.6<br>0294420000 AP AKZ4 KRG<br>I.4<br>0294460000 AP AKZ4<br>I.6|**Order No.**<br>**Type**<br>**Page**<br>0294460000 AP AKZ4<br>E.8<br>0294460000 AP AKZ4<br>E.9<br>0294460000 AP AKZ4<br>I.4<br>0294460000 AP AKZ4<br>E.11<br>0294460000 AP AKZ4<br>E.13<br>0294460000 AP AKZ4<br>E.12<br>0294460000 AP AKZ4<br>E.10<br>0294460000 AP AKZ4<br>E.3<br>0294480000 AP AKZ4 BL<br>I.6<br>0294480000 AP AKZ4 BL<br>E.3<br>0294500000 GZ 2.0A<br>B.26<br>0294500000 GZ 2.0A<br>A.28<br>0294500000 GZ 2.0A<br>A.23<br>0294600000 GZ 5.0A<br>B.26<br>0294600000 GZ 5.0A<br>A.28<br>0295700000 GZ 3.0A<br>A.28<br>0295700000 GZ 3.0A<br>B.26<br>0295700000 GZ 3.0A<br>A.23<br>0295800000 GZ 7.0A<br>A.28<br>0295800000 GZ 7.0A<br>B.26<br>0295900000 FKSC M5X8 D9/SW2.5<br>H.14<br>0296200000 BFSC M3X30<br>B.28<br>0296200000 BFSC M3X30<br>A.11<br>0296200000 BFSC M3X30<br>I.10<br>0296700000 BFSC M5X8 Schlitz<br>H.3<br>0296800000 VH 5/4/2.8 AKZ4<br>I.9<br>0297100000 TW SAK2.5 HP/TF/GE/1<br>B.16<br>0297100000 TW SAK2.5 HP/TF/GE/1<br>B.18<br>0297100000 TW SAK2.5 HP/TF/GE/1<br>A.40<br>0297200000 QL 2 DLI<br>I.9<br>0297300000 QL 3 DLI<br>I.9<br>0297520000 SAKS 3 G/5X30 500V<br>B.23<br>0297600000 AD 3 SAK4<br>I.17<br>0297700000 AD 3 SAK6N<br>I.17<br>0297800000 AD 3 SAK16<br>B.4<br>0297800000 AD 3 SAK16<br>I.17<br>0297900000 AD 3 SAK2.5<br>B.2<br>0297900000 AD 3 SAK2.5<br>A.12<br>0297900000 AD 3 SAK2.5<br>C.2<br>0297900000 AD 3 SAK2.5<br>I.17<br>0297900000 AD 3 SAK2.5<br>A.2<br>0298020000 AST 3 6.3 KRG<br>B.42<br>0298120000 AP AST3+4 KRG<br>A.36<br>0298120000 AP AST3+4 KRG<br>B.43<br>0298120000 AP AST3+4 KRG<br>B.42<br>0298120000 AP AST3+4 KRG<br>I.4<br>0298120000 AP AST3+4 KRG<br>I.6<br>0298700000 VH 24.5/8/5 SAK35<br>A.5<br>0298700000 VH 24.5/8/5 SAK35<br>B.8<br>0298700000 VH 24.5/8/5 SAK35<br>A.4<br>0298700000 VH 24.5/8/5 SAK35<br>B.5<br>0298700000 VH 24.5/8/5 SAK35<br>I.12<br>0298700000 VH 24.5/8/5 SAK35<br>B.4<br>0298900000 BFSC M4X35<br>A.4<br>0298900000 BFSC M4X35<br>B.5<br>0298900000 BFSC M4X35<br>B.4<br>0298900000 BFSC M4X35<br>A.5<br>0298900000 BFSC M4X35<br>B.8<br>0298900000 BFSC M4X35<br>I.12<br>0299600000 PS 4 F.STB 4<br>A.5<br>0299600000 PS 4 F.STB 4<br>B.7<br>0299600000 PS 4 F.STB 4<br>A.6<br>0299600000 PS 4 F.STB 4<br>A.3<br>0299600000 PS 4 F.STB 4<br>D.9<br>0299600000 PS 4 F.STB 4<br>A.4<br>0299600000 PS 4 F.STB 4<br>B.4<br>0299600000 PS 4 F.STB 4<br>A.20<br>0299600000 PS 4 F.STB 4<br>A.33<br>0299600000 PS 4 F.STB 4<br>B.5<br>0299600000 PS 4 F.STB 4<br>C.3<br>0299600000 PS 4 F.STB 4<br>B.19<br>0299600000 PS 4 F.STB 4<br>B.30<br>0299600000 PS 4 F.STB 4<br>B.3<br>0299600000 PS 4 F.STB 4<br>I.14<br>0299600000 PS 4 F.STB 4<br>A.9<br>0299600000 PS 4 F.STB 4<br>B.8<br>0299600000 PS 4 F.STB 4<br>B.31<br>0299600000 PS 4 F.STB 4<br>B.9<br>0299600000 PS 4 F.STB 4<br>B.32<br>0299600000 PS 4 F.STB 4<br>A.10<br>0299600000 PS 4 F.STB 4<br>D.6<br>0299600000 PS 4 F.STB 4<br>B.29<br>0299600000 PS 4 F.STB 4<br>B.28<br>0299600000 PS 4 F.STB 4<br>C.4<br>0299600000 PS 4 F.STB 4<br>A.32<br>0299600000 PS 4 F.STB 4<br>A.8<br>0299700000 VH 13.6/7/4.2 SAKA10<br>A.20<br>0299700000 VH 13.6/7/4.2 SAKA10<br>B.19<br>0299860000 SH 1<br>H.4<br>**0300000000**<br>0300720000 AKA 2.5<br>E.12<br>0300770000 AKA 2.5 BL<br>E.12<br>0300800000 VH 12.5/5/3.5 SAK10-2.5<br>I.10<br>0301420000 AP RSF2 KRG<br>I.6<br>0302820000 TW SAK2.5 KRG<br>A.7<br>0302820000 TW SAK2.5 KRG<br>B.6<br>0302860000 TW SAK2.5<br>A.40<br>0302860000 TW SAK2.5<br>A.2|**Order No.**<br>**Type**<br>**Page**<br>0302860000 TW SAK2.5<br>B.39<br>0302860000 TW SAK2.5<br>B.38<br>0302860000 TW SAK2.5<br>B.34<br>0302860000 TW SAK2.5<br>B.2<br>0302860000 TW SAK2.5<br>C.2<br>0302870000 TW SAK2.5 KRG/BL<br>B.6<br>0302870000 TW SAK2.5 KRG/BL<br>A.7<br>0302880000 TW SAK2.5 BL<br>A.2<br>0302880000 TW SAK2.5 BL<br>C.2<br>0302880000 TW SAK2.5 BL<br>B.2<br>0302880000 TW SAK2.5 BL<br>B.39<br>0303000000 KISC M3X20.5/10 EK4<br>D.3<br>0303000000 KISC M3X20.5/10 EK4<br>I.10<br>0303000000 KISC M3X20.5/10 EK4<br>D.2<br>0303000000 KISC M3X20.5/10 EK4<br>B.28<br>0303000000 KISC M3X20.5/10 EK4<br>I.9<br>0303000000 KISC M3X20.5/10 EK4<br>A.11<br>0303200000 VH 4.5/5/3.5 SAK6N-16<br>I.10<br>0303300000 BFSC M2.5X18 PA/RT<br>E.11<br>0303300000 BFSC M2.5X18 PA/RT<br>B.11<br>0303300000 BFSC M2.5X18 PA/RT<br>I.17<br>0303300000 BFSC M2.5X18 PA/RT<br>A.12<br>0303300000 BFSC M2.5X18 PA/RT<br>E.12<br>0303300000 BFSC M2.5X18 PA/RT<br>A.13<br>0303300000 BFSC M2.5X18 PA/RT<br>E.10<br>0303400000 AD 4 AKZ4<br>E.10<br>0303400000 AD 4 AKZ4<br>B.39<br>0303400000 AD 4 AKZ4<br>E.12<br>0303400000 AD 4 AKZ4<br>E.11<br>0303400000 AD 4 AKZ4<br>B.45<br>0303400000 AD 4 AKZ4<br>B.11<br>0303400000 AD 4 AKZ4<br>A.7<br>0303400000 AD 4 AKZ4<br>A.40<br>0303400000 AD 4 AKZ4<br>I.17<br>0303400000 AD 4 AKZ4<br>A.13<br>0303400000 AD 4 AKZ4<br>B.6<br>0303520000 SAK 35 KRG<br>B.8<br>0303560000 SAK 35<br>B.4<br>0303580000 SAK 35 BL<br>B.4<br>0303620000 AP SAK35 KRG<br>I.6<br>0303620000 AP SAK35 KRG<br>I.4<br>0303620000 AP SAK35 KRG<br>B.8<br>0303620000 AP SAK35 KRG<br>B.9<br>0303620000 AP SAK35 KRG<br>A.9<br>0303660000 AP SAK35/TW SAK16<br>B.5<br>0303660000 AP SAK35/TW SAK16<br>I.6<br>0303660000 AP SAK35/TW SAK16<br>C.4<br>0303660000 AP SAK35/TW SAK16<br>I.4<br>0303660000 AP SAK35/TW SAK16<br>A.4<br>0303660000 AP SAK35/TW SAK16<br>A.5<br>0303660000 AP SAK35/TW SAK16<br>B.4<br>0303670000 AP SAK35 KRG/BL<br>B.8<br>0303670000 AP SAK35 KRG/BL<br>B.9<br>0303670000 AP SAK35 KRG/BL<br>A.9<br>0303670000 AP SAK35 KRG/BL<br>I.6<br>0303680000 AP SAK35/TW SAK16 BL<br>B.7<br>0303680000 AP SAK35/TW SAK16 BL<br>C.4<br>0303680000 AP SAK35/TW SAK16 BL<br>I.6<br>0303680000 AP SAK35/TW SAK16 BL<br>B.5<br>0303680000 AP SAK35/TW SAK16 BL<br>A.5<br>0303680000 AP SAK35/TW SAK16 BL<br>A.4<br>0303680000 AP SAK35/TW SAK16 BL<br>B.4<br>0303860000 ADK 1/1.5<br>E.11<br>0304000000 VH 13/5/3.5 SAK 10<br>I.10<br>0304320000 TW SAK35 KRG<br>B.9<br>0304320000 TW SAK35 KRG<br>A.9<br>0304320000 TW SAK35 KRG<br>B.8<br>0304360000 TW SAK35<br>A.5<br>0304360000 TW SAK35<br>C.4<br>0304360000 TW SAK35<br>B.4<br>0304360000 TW SAK35<br>A.4<br>0304360000 TW SAK35<br>B.5<br>0306120000 SAKS 1/32 G20 GL 230VAC<br>B.22<br>0307300000 QVS 2 SAKT1+2<br>B.31<br>0307300000 QVS 2 SAKT1+2<br>A.32<br>0307300000 QVS 2 SAKT1+2<br>I.20<br>0307300000 QVS 2 SAKT1+2<br>A.33<br>0307300000 QVS 2 SAKT1+2<br>B.32<br>0307400000 QVS 4 SAKT1+2<br>B.32<br>0307400000 QVS 4 SAKT1+2<br>B.31<br>0307400000 QVS 4 SAKT1+2<br>A.32<br>0307400000 QVS 4 SAKT1+2<br>A.33<br>0307400000 QVS 4 SAKT1+2<br>I.20<br>0308000000<br>I.10<br>0309220000 AP SAK2.5L KRG<br>I.4<br>0309220000 AP SAK2.5L KRG<br>B.45<br>0309220000 AP SAK2.5L KRG<br>I.6<br>0309270000 AP SAK2.5L KRG BL<br>I.6<br>0309270000 AP SAK2.5L KRG BL<br>B.45<br>0309320000 SAKS 1/32 G25 GL 230VAC<br>B.23<br>0309400000 VH 27/5/3.5 SAK10-35<br>I.10<br>0309400000 VH 27/5/3.5 SAK10-35<br>B.28<br>0309600000 VH 21/5/3.5 SAK16-35<br>A.11<br>0309600000 VH 21/5/3.5 SAK16-35<br>B.28<br>0309700000 VH 16/5/3.5 SAK10-35<br>I.10<br>0309700000 VH 16/5/3.5 SAK10-35<br>A.33<br>0309700000 VH 16/5/3.5 SAK10-35<br>B.32<br>0309800000 BFSC M3X35<br>B.28<br>0309800000 BFSC M3X35<br>I.10|
|---|---|---|
**X.17**
**X**
|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|0328400000|E 14/10A RT|B.26|0336500000|Q 3 AKZ4|B.57|0337200000|Q 4 SAK2.5|B.2|0344400000|BFSC M5X45 PA/NA|B.9|
|0328400000|E 14/10A RT|A.28|0336500000|Q 3 AKZ4|A.55|0337200000|Q 4 SAK2.5|C.2|0345300000|QL 2 SAK70|A.6|
|0328500000|E 14/16A GR|B.24|0336500000|Q 3 AKZ4|E.11|0337660000|SAK 10/EN|C.3|0345300000|QL 2 SAK70|B.9|
|0328500000|E 14/16A GR|B.26|0336500000|Q 3 AKZ4|I.11|0338100000|QL 10 SAK2.5|I.9|0345300000|QL 2 SAK70|I.9|
|0328500000|E 14/16A GR|A.28|0336500000|Q 3 AKZ4|B.56|0338100000|QL 10 SAK2.5|A.33|0345500000|VH 30.5/11/5.5 SAK70|I.9|
|0328500000|E 14/16A GR|A.26|0336600000|Q 4 AKZ4|B.58|0338100000|QL 10 SAK2.5|B.32|0345500000|VH 30.5/11/5.5 SAK70|B.9|
|0328600000|P 14/6 D01 GN SAKS4|B.27|0336600000|Q 4 AKZ4|A.55|0338100000|QL 10 SAK2.5|I.10|0345500000|VH 30.5/11/5.5 SAK70|A.6|
|0328600000|P 14/6 D01 GN SAKS4|A.26|0336600000|Q 4 AKZ4|A.54|0338200000|QL 10 SAK4|B.37|0345600000|BFSC M5X45|A.6|
|0328600000<br>0328600000<br>0328700000<br>0328700000|P 14/6 D01 GN SAKS4<br>P 14/6 D01 GN SAKS4<br>P 14/10 D01 RT SAKS4<br>P 14/10 D01 RT SAKS4|B.24<br>A.29<br>A.26<br>B.27|0336600000<br>0336600000<br>0336600000<br>0336600000|Q 4 AKZ4<br>Q 4 AKZ4<br>Q 4 AKZ4<br>Q 4 AKZ4|A.12<br>B.61<br>A.53<br>A.39|0338200000<br>0338200000<br>0338200000<br>0338200000|QL 10 SAK4<br>QL 10 SAK4<br>QL 10 SAK4<br>QL 10 SAK4|A.38<br>A.37<br>I.10<br>I.9|0345600000<br>0345600000<br>0346100000<br>0346100000|BFSC M5X45<br>BFSC M5X45<br>SS M5 D 128-A 5<br>SS M5 D 128-A 5|B.9<br>I.9<br>A.10<br>B.9|
|0328700000|P 14/10 D01 RT SAKS4|B.24|0336600000|Q 4 AKZ4|B.59|0338200000|QL 10 SAK4|B.44|0346100000|SS M5 D 128-A 5|A.6|
|0328700000|P 14/10 D01 RT SAKS4|A.29|0336600000|Q 4 AKZ4|B.60|0338300000|QL 10 SAK6N|B.31|0346200000|KISC M3X6 SAKS1|I.9|
|0328920000|SAKS 3/35 G/5X30 500V|A.25|0336600000|Q 4 AKZ4|A.56|0338300000|QL 10 SAK6N|A.11|0346460000|AKZ 4 LL VS|E.11|
|0329120000|AP SAKT2 KRG|I.6|0336600000|Q 4 AKZ4|B.57|0338300000|QL 10 SAK6N|I.9|0347960000|TSK 31.5 GR|I.16|
|0329120000|AP SAKT2 KRG|I.4|0336600000|Q 4 AKZ4|E.3|0338300000|QL 10 SAK6N|I.10|0348260000|TW AKZ4|E.9|
|0329300000|QVS 3 SAKT1+2|I.20|0336600000|Q 4 AKZ4|A.50|0338300000|QL 10 SAK6N|I.21|0348260000|TW AKZ4|E.13|
|0329300000|QVS 3 SAKT1+2|A.33|0336600000|Q 4 AKZ4|A.38|0338300000|QL 10 SAK6N|B.28|0348260000|TW AKZ4|E.12|
|0329300000|QVS 3 SAKT1+2|B.31|0336600000|Q 4 AKZ4|A.51|0338300000|QL 10 SAK6N|B.32|0348260000|TW AKZ4|E.3|
|0329300000|QVS 3 SAKT1+2|B.32|0336600000|Q 4 AKZ4|E.9|0338300000|QL 10 SAK6N|A.32|0348260000|TW AKZ4|E.8|
|0329300000|QVS 3 SAKT1+2|A.32|0336600000|Q 4 AKZ4|B.11|0338300000|QL 10 SAK6N|A.33|0348260000|TW AKZ4|E.11|
|0329660000|AP AKZ1.5W|E.10|0336600000|Q 4 AKZ4|I.11|0338400000|QL 10 SAKB10|B.30|0348260000|TW AKZ4|E.10|
|0329660000|AP AKZ1.5W|I.6|0336600000|Q 4 AKZ4|A.52|0338500000|QL 10 SAKA10|B.19|0348280000|TW AKZ4 BL|E.3|
|0329660000|AP AKZ1.5W|I.4|0336600000|Q 4 AKZ4|A.13|0338500000|QL 10 SAKA10|B.30|0348660000|EWK AKA 2.5|H.13|
||||0336600000|Q 4 AKZ4|B.37|0338600000|QL 10 SAK35|C.4|0348700000|VH 23/6/4.2 SAKA10|B.30|
|**0330000000**|||0336600000<br>0336600000|Q 4 AKZ4<br>Q 4 AKZ4|E.12<br>B.10|0338600000<br>0338600000|QL 10 SAK35<br>QL 10 SAK35|B.8<br>A.5|0348900000<br>0348900000|SSCH 10X3X1000 CU/SN<br>SSCH 10X3X1000 CU/SN|G.7<br>G.6|
|0330620000|SAKT 2/LT STB|B.32|0336600000|Q 4 AKZ4|B.38|0338600000|QL 10 SAK35|A.4|0348900000|SSCH 10X3X1000 CU/SN|G.5|
|0330800000|TS 35X7.5 2M/AL/BK|H.11|0336600000|Q 4 AKZ4|E.13|0338600000|QL 10 SAK35|I.11|0348900000|SSCH 10X3X1000 CU/SN|G.4|
|0330930000|DS 9 SAK2.5|I.12|0336600000|Q 4 AKZ4|E.11|0338600000|QL 10 SAK35|I.9|0348900000|SSCH 10X3X1000 CU/SN|H.3|
|0334520000|AST 5 SF 6.3 KRG|B.43|0336600000|Q 4 AKZ4|E.10|0338600000|QL 10 SAK35|B.4|0348900000|SSCH 10X3X1000 CU/SN|A.31|
|0334700000|BS 25 O.IH SAKT1|B.32|0336600000|Q 4 AKZ4|B.56|0338600000|QL 10 SAK35|B.5|0348900000|SSCH 10X3X1000 CU/SN|A.30|
|0334700000|BS 25 O.IH SAKT1|A.32|0336700000|Q 2 SAK4|C.2|0338800000|QL 10 SAKS1|I.9||||
|0334700000<br>0334700000|BS 25 O.IH SAKT1<br>BS 25 O.IH SAKT1|I.21<br>B.31|0336700000<br>0336700000|Q 2 SAK4<br>Q 2 SAK4|C.4<br>A.37|0338800000<br>0338800000|QL 10 SAKS1<br>QL 10 SAKS1|B.23<br>A.25|**0350000000**|||
|0334700000|BS 25 O.IH SAKT1|A.33|0336700000|Q 2 SAK4|B.3|0338800000|QL 10 SAKS1|A.24|0351460000|SAK 2.5 SL|B.39|
|0334820000|AKZ 4L SL VS KRG|E.12|0336700000|Q 2 SAK4|C.5|0338900000|QL 10 SAKS2|A.26|0351820000|TW SAKT2|A.33|
|0334860000|AKZ 4L SL VS|E.10|0336700000|Q 2 SAK4|I.9|0338900000|QL 10 SAKS2|A.27|0352080000|HP NT2.5 BL|A.30|
|0334900000|MB M6/M4 GR|H.15|0336700000|Q 2 SAK4|B.36|0338900000|QL 10 SAKS2|I.9|0352880000|HP NT6/10 BL|A.31|
|0335200000|BS 25 IH/SW SAKT1|I.21|0336700000|Q 2 SAK4|A.36|0338900000|QL 10 SAKS2|B.25|0352880000|HP NT6/10 BL|A.30|
|0335300000|BS 25 IH/GR SAKT1|I.21|0336700000|Q 2 SAK4|A.3|0338900000|QL 10 SAKS2|B.24|0352920000|SAK 4 SS 6.3/KRG|B.44|
|0335400000|BS 25 IH/BL SAKT1|I.21|0336700000|Q 2 SAK4|D.6|0339000000|QL 10 SAKS4|A.27|0353500000|FKSC M6X12 D9/SW3|H.14|
|0335500000|BS 25 IH/RT SAKT1|I.21|0336700000|Q 2 SAK4|A.7|0339000000|QL 10 SAKS4|I.9|0353660000|TSCH 2|A.33|
|0335600000|BS 25 IH/GN SAKT1|I.21|0336700000|Q 2 SAK4|B.6|0339000000|QL 10 SAKS4|B.24|0353660000|TSCH 2|B.31|
|0335700000|BS 25 IH/GE SAKT1|I.21|0336700000|Q 2 SAK4|B.42|0339000000|QL 10 SAKS4|B.25|0353660000|TSCH 2|B.32|
|0335800000|BS 25 IH/VI SAKT1|I.21|0336700000|Q 2 SAK4|B.43|0339000000|QL 10 SAKS4|A.26|0353660000|TSCH 2|A.32|
|0336400000|Q 2 AKZ4|E.10|0336800000|Q 3 SAK4|A.3|0339410000|SK E14 SAKS4|A.26|0354361187|DEK 5 FWZ L1-PE|K.7|
|0336400000|Q 2 AKZ4|A.39|0336800000|Q 3 SAK4|A.37|0339410000|SK E14 SAKS4|B.24|0354361203|DEK 5 FWZ L1-EIK|K.7|
|0336400000|Q 2 AKZ4|B.61|0336800000|Q 3 SAK4|B.36|0339760000|SAK 16/EN|C.3|0354560000|EK 4|B.12|
|0336400000|Q 2 AKZ4|A.55|0336800000|Q 3 SAK4|C.4|0339860000|SAK 35/EN|C.4|0354660000|EK 10|B.13|
|0336400000|Q 2 AKZ4|A.56|0336800000|Q 3 SAK4|I.9||||0354760000|EK 35|B.13|
|0336400000<br>0336400000|Q 2 AKZ4<br>Q 2 AKZ4|B.37<br>B.57|0336800000<br>0336800000|Q 3 SAK4<br>Q 3 SAK4|B.6<br>C.5|**0340000000**|||0355460000<br>0355480000|DK 4<br>DK 4 BL|B.10<br>B.10|
|0336400000|Q 2 AKZ4|E.11|0336800000|Q 3 SAK4|D.6|0340160000|AKZ 1.5L VS|E.10|0357400000|SSCH 15X6X1000 CU/SN|H.3|
|0336400000|Q 2 AKZ4|B.38|0336800000|Q 3 SAK4|A.7|0340460000|AKZ 1.5|E.2|0357520000|SAKC 4/35|A.20|
|0336400000|Q 2 AKZ4|E.13|0336800000|Q 3 SAK4|B.42|0340480000|AKZ 1.5 BL|E.2|0358460000|QVS 2/S SAKT1+2|I.20|
|0336400000|Q 2 AKZ4|A.12|0336800000|Q 3 SAK4|B.43|0340560000|AP AKZ1.5|E.2|0358500000|STB 7/D4/2.3/M3 ZB/SAKC|B.19|
|0336400000|Q 2 AKZ4|B.60|0336800000|Q 3 SAK4|B.3|0340560000|AP AKZ1.5|I.4|0358500000|STB 7/D4/2.3/M3 ZB/SAKC|I.15|
|0336400000|Q 2 AKZ4|B.10|0336800000|Q 3 SAK4|A.36|0340560000|AP AKZ1.5|I.6|0359000000|KISC M3X15/6 SAK2.5|I.9|
|0336400000|Q 2 AKZ4|B.11|0336800000|Q 3 SAK4|C.2|0340580000|AP AKZ1.5 BL|E.2|0359000000|KISC M3X15/6 SAK2.5|I.10|
|0336400000|Q 2 AKZ4|E.12|0336900000|Q 4 SAK4|A.37|0340580000|AP AKZ1.5 BL|I.6|0359260000|AP DK4|A.12|
|0336400000|Q 2 AKZ4|E.9|0336900000|Q 4 SAK4|B.3|0340670000|SAKC 4/2STB7 BL|I.7|0359260000|AP DK4|B.38|
|0336400000|Q 2 AKZ4|E.3|0336900000|Q 4 SAK4|A.36|0340720000|SAKC 4 KRG|B.19|0359260000|AP DK4|A.56|
|0336400000|Q 2 AKZ4|A.38|0336900000|Q 4 SAK4|C.4|0340820000|SAK 70 KRG|B.9|0359260000|AP DK4|A.51|
|0336400000|Q 2 AKZ4|A.50|0336900000|Q 4 SAK4|B.43|0340870000|SAK 70 KRG/BL|B.9|0359260000|AP DK4|B.61|
|0336400000|Q 2 AKZ4|B.56|0336900000|Q 4 SAK4|C.2|0340870000|SAK 70 KRG/BL|I.7|0359260000|AP DK4|B.59|
|0336400000|Q 2 AKZ4|I.11|0336900000|Q 4 SAK4|C.5|0340920000|AP 70 SAK70 KRG|I.6|0359260000|AP DK4|B.58|
|0336400000|Q 2 AKZ4|A.51|0336900000|Q 4 SAK4|B.36|0340920000|AP 70 SAK70 KRG|B.9|0359260000|AP DK4|B.57|
|0336400000|Q 2 AKZ4|A.53|0336900000|Q 4 SAK4|I.9|0340920000|AP 70 SAK70 KRG|I.4|0359260000|AP DK4|A.53|
|0336400000|Q 2 AKZ4|A.52|0336900000|Q 4 SAK4|B.42|0340960000|AP SAK70/35|A.6|0359260000|AP DK4|A.52|
|0336400000|Q 2 AKZ4|A.13|0336900000|Q 4 SAK4|B.6|0340960000|AP SAK70/35|I.6|0359260000|AP DK4|A.55|
|0336400000|Q 2 AKZ4|I.9|0336900000|Q 4 SAK4|A.7|0340960000|AP SAK70/35|I.4|0359260000|AP DK4|B.60|
|0336400000|Q 2 AKZ4|B.58|0336900000|Q 4 SAK4|D.6|0341000000|STB 30.5 IH/SW|I.20|0359260000|AP DK4|A.54|
|0336400000|Q 2 AKZ4|B.59|0336900000|Q 4 SAK4|A.3|0341000000|STB 30.5 IH/SW|I.15|0359260000|AP DK4|B.10|
|0336400000|Q 2 AKZ4|A.54|0337000000|Q 2 SAK2.5|B.39|0341100000|STB 30.5 IH/GR|I.20|0359260000|AP DK4|A.50|
|0336500000|Q 3 AKZ4|A.50|0337000000|Q 2 SAK2.5|A.40|0341100000|STB 30.5 IH/GR|I.15|0359260000|AP DK4|B.56|
|0336500000|Q 3 AKZ4|B.10|0337000000|Q 2 SAK2.5|B.38|0341200000|STB 30.5 IH/BL|I.20|0359260000|AP DK4|I.6|
|0336500000|Q 3 AKZ4|B.60|0337000000|Q 2 SAK2.5|A.2|0341200000|STB 30.5 IH/BL|I.15|0359280000|AP DK4 BL|A.12|
|0336500000|Q 3 AKZ4|B.61|0337000000|Q 2 SAK2.5|A.7|0341300000|STB 30.5 IH/RT|I.20|0359280000|AP DK4 BL|B.38|
|0336500000|Q 3 AKZ4|E.10|0337000000|Q 2 SAK2.5|B.2|0341300000|STB 30.5 IH/RT|I.15|0359280000|AP DK4 BL|I.6|
|0336500000|Q 3 AKZ4|A.51|0337000000|Q 2 SAK2.5|B.6|0341400000|STB 30.5 IH/GN|I.20|0359280000|AP DK4 BL|B.10|
|0336500000|Q 3 AKZ4|E.9|0337000000|Q 2 SAK2.5|B.45|0341400000|STB 30.5 IH/GN|I.15|0359310000|SK E18 SAKS5|B.25|
|0336500000|Q 3 AKZ4|A.13|0337000000|Q 2 SAK2.5|C.2|0341500000|STB 30.5 IH/GE|I.15|0359310000|SK E18 SAKS5|A.27|
|0336500000|Q 3 AKZ4|B.58|0337100000|Q 3 SAK2.5|B.6|0341500000|STB 30.5 IH/GE|I.20|0359420000|SAKS 5 380AC|B.25|
|0336500000|Q 3 AKZ4|E.3|0337100000|Q 3 SAK2.5|B.38|0341600000|STB 30.5 IH/VI|I.15||||
|0336500000<br>0336500000|Q 3 AKZ4<br>Q 3 AKZ4|A.52<br>E.13|0337100000<br>0337100000|Q 3 SAK2.5<br>Q 3 SAK2.5|A.2<br>C.2|0341600000<br>0341700000|STB 30.5 IH/VI<br>QL 10 RSF1+2|I.20<br>B.29|**0360000000**|||
|0336500000|Q 3 AKZ4|B.59|0337100000|Q 3 SAK2.5|B.39|0341700000|QL 10 RSF1+2|B.28|0361300000|E 18/20A BL|A.28|
|0336500000|Q 3 AKZ4|B.38|0337100000|Q 3 SAK2.5|B.45|0343300000|STB 25 IH/RT|I.15|0361300000|E 18/20A BL|B.25|
|0336500000|Q 3 AKZ4|A.12|0337100000|Q 3 SAK2.5|A.7|0343300000|STB 25 IH/RT|I.20|0361300000|E 18/20A BL|A.27|
|0336500000|Q 3 AKZ4|E.12|0337100000|Q 3 SAK2.5|B.2|0343400000|STB 25 IH/BL|I.15|0361300000|E 18/20A BL|B.26|
|0336500000|Q 3 AKZ4|I.9|0337100000|Q 3 SAK2.5|A.40|0343400000|STB 25 IH/BL|I.20|0361400000|E 18/25A GE|B.26|
|0336500000|Q 3 AKZ4|A.39|0337200000|Q 4 SAK2.5|A.40|0343800000|QB 10 SAKT1|I.21|0361400000|E 18/25A GE|B.25|
|0336500000|Q 3 AKZ4|A.54|0337200000|Q 4 SAK2.5|A.2|0344300000|AD 3 SAK70|B.9|0361400000|E 18/25A GE|A.28|
|0336500000|Q 3 AKZ4|B.11|0337200000|Q 4 SAK2.5|B.6|0344300000|AD 3 SAK70|A.6|0361400000|E 18/25A GE|A.27|
|0336500000|Q 3 AKZ4|B.37|0337200000|Q 4 SAK2.5|B.45|0344300000|AD 3 SAK70|I.17|0361500000|E 18/35A SW|B.26|
|0336500000|Q 3 AKZ4|A.56|0337200000|Q 4 SAK2.5|A.7|0344400000|BFSC M5X45 PA/NA|A.10|0361500000|E 18/35A SW|A.28|
|0336500000|Q 3 AKZ4|A.38|0337200000|Q 4 SAK2.5|B.39|0344400000|BFSC M5X45 PA/NA|A.6|0361600000|E 18/50A WS|B.25|
|0336500000|Q 3 AKZ4|A.53|0337200000|Q 4 SAK2.5|B.38|0344400000|BFSC M5X45 PA/NA|I.17|0361600000|E 18/50A WS|A.27|
**X.18**
|**Order No.**<br>**Type**<br>**Page**<br>0361600000 E 18/50A WS<br>A.28<br>0361600000 E 18/50A WS<br>B.26<br>0361700000 E 18/63A KU<br>B.26<br>0361700000 E 18/63A KU<br>A.27<br>0361700000 E 18/63A KU<br>B.25<br>0361700000 E 18/63A KU<br>A.28<br>0361800000 P 18/20 D02 BL SAKS5<br>A.29<br>0361800000 P 18/20 D02 BL SAKS5<br>B.25<br>0361800000 P 18/20 D02 BL SAKS5<br>A.27<br>0361800000 P 18/20 D02 BL SAKS5<br>B.27<br>0361900000 P 18/25 D02 GE SAKS5<br>B.25<br>0361900000 P 18/25 D02 GE SAKS5<br>B.27<br>0361900000 P 18/25 D02 GE SAKS5<br>A.29<br>0361900000 P 18/25 D02 GE SAKS5<br>A.27<br>0362000000 P 18/35 D02 SW SAKS5<br>B.27<br>0362000000 P 18/35 D02 SW SAKS5<br>B.25<br>0362000000 P 18/35 D02 SW SAKS5<br>A.29<br>0362000000 P 18/35 D02 SW SAKS5<br>A.27<br>0362100000 P 18/50 D02 WS SAKS5<br>B.27<br>0362100000 P 18/50 D02 WS SAKS5<br>B.25<br>0362100000 P 18/50 D02 WS SAKS5<br>A.29<br>0362100000 P 18/50 D02 WS SAKS5<br>A.27<br>0362460000 AKZ 4 SS WA 2X2.8<br>E.8<br>0362800000 BFSC M4X20<br>B.19<br>0362800000 BFSC M4X20<br>A.20<br>0363360000 TSCH 4 AKZ4<br>E.13<br>0363360000 TSCH 4 AKZ4<br>A.55<br>0363360000 TSCH 4 AKZ4<br>B.57<br>0363360000 TSCH 4 AKZ4<br>A.51<br>0363360000 TSCH 4 AKZ4<br>A.53<br>0363360000 TSCH 4 AKZ4<br>E.3<br>0363360000 TSCH 4 AKZ4<br>A.54<br>0363360000 TSCH 4 AKZ4<br>A.52<br>0363360000 TSCH 4 AKZ4<br>E.12<br>0363360000 TSCH 4 AKZ4<br>E.11<br>0363360000 TSCH 4 AKZ4<br>B.60<br>0363360000 TSCH 4 AKZ4<br>B.56<br>0363360000 TSCH 4 AKZ4<br>B.59<br>0363360000 TSCH 4 AKZ4<br>B.38<br>0363360000 TSCH 4 AKZ4<br>A.50<br>0363360000 TSCH 4 AKZ4<br>B.61<br>0363360000 TSCH 4 AKZ4<br>E.10<br>0363360000 TSCH 4 AKZ4<br>B.58<br>0363660000 DK 4QV/35<br>A.13<br>0363680000 DK 4QV/35 BL<br>A.13<br>0364200000 AK 95<br>H.5<br>0364300000 TS 32X16.2 2M/CU/BK<br>H.10<br>0366860000 TSCH 3 SAKD2.5 N<br>B.2<br>0366860000 TSCH 3 SAKD2.5 N<br>A.2<br>0367800000 Q 2 SAKD2.5N<br>B.2<br>0367800000 Q 2 SAKD2.5N<br>A.2<br>0367900000 Q 3 SAKD2.5N<br>B.2<br>0367900000 Q 3 SAKD2.5N<br>A.2<br>0368000000 Q 4 SAKD2.5N<br>A.2<br>0368000000 Q 4 SAKD2.5N<br>B.2<br>0368100000 Q 10 SAKD2.5N<br>B.2<br>0368100000 Q 10 SAKD2.5N<br>A.2<br>0368200000 Q 2 AKZ1.5<br>I.11<br>0368200000 Q 2 AKZ1.5<br>E.2<br>0368200000 Q 2 AKZ1.5<br>E.10<br>0368300000 Q 3 AKZ1.5<br>I.11<br>0368300000 Q 3 AKZ1.5<br>E.10<br>0368300000 Q 3 AKZ1.5<br>E.2<br>0368400000 Q 4 AKZ1.5<br>E.10<br>0368400000 Q 4 AKZ1.5<br>I.11<br>0368400000 Q 4 AKZ1.5<br>E.2<br>0368500000 Q 10 AKZ1.5<br>E.2<br>0368500000 Q 10 AKZ1.5<br>I.11<br>0368500000 Q 10 AKZ1.5<br>E.10<br>0368600000 Q 10 AKZ4<br>E.3<br>0368600000 Q 10 AKZ4<br>E.9<br>0368600000 Q 10 AKZ4<br>B.38<br>0368600000 Q 10 AKZ4<br>E.12<br>0368600000 Q 10 AKZ4<br>A.56<br>0368600000 Q 10 AKZ4<br>E.11<br>0368600000 Q 10 AKZ4<br>E.13<br>0368600000 Q 10 AKZ4<br>A.13<br>0368600000 Q 10 AKZ4<br>B.37<br>0368600000 Q 10 AKZ4<br>A.38<br>0368600000 Q 10 AKZ4<br>B.11<br>0368600000 Q 10 AKZ4<br>A.39<br>0368600000 Q 10 AKZ4<br>A.52<br>0368600000 Q 10 AKZ4<br>B.10<br>0368600000 Q 10 AKZ4<br>A.12<br>0368600000 Q 10 AKZ4<br>E.10<br>0368700000 Q 10 SAK2.5<br>I.9<br>0368700000 Q 10 SAK2.5<br>A.2<br>0368700000 Q 10 SAK2.5<br>A.7<br>0368700000 Q 10 SAK2.5<br>B.2<br>0368700000 Q 10 SAK2.5<br>B.45<br>0368700000 Q 10 SAK2.5<br>B.38<br>0368700000 Q 10 SAK2.5<br>B.39<br>0368700000 Q 10 SAK2.5<br>B.6<br>0368700000 Q 10 SAK2.5<br>A.40<br>0368700000 Q 10 SAK2.5<br>C.2<br>0368800000 Q 10 SAK4<br>B.3<br>0368800000 Q 10 SAK4<br>B.6<br>0368800000 Q 10 SAK4<br>B.36<br>0368800000 Q 10 SAK4<br>C.2<br>0368800000 Q 10 SAK4<br>A.3|**Order No.**<br>**Type**<br>**Page**<br>0368800000 Q 10 SAK4<br>B.42<br>0368800000 Q 10 SAK4<br>C.5<br>0368800000 Q 10 SAK4<br>B.43<br>0368800000 Q 10 SAK4<br>I.9<br>0368800000 Q 10 SAK4<br>D.6<br>0368800000 Q 10 SAK4<br>A.36<br>0368800000 Q 10 SAK4<br>A.37<br>0368800000 Q 10 SAK4<br>C.4<br>0368800000 Q 10 SAK4<br>A.7<br>0368900000 H35,0/18<br>J.33<br>0369000000 Q 2 AKZ4SS<br>I.11<br>0369000000 Q 2 AKZ4SS<br>E.8<br>0369100000 Q 3 AKZ4SS<br>I.11<br>0369100000 Q 3 AKZ4SS<br>E.8<br>0369200000 Q 4 AKZ4SS<br>I.11<br>0369200000 Q 4 AKZ4SS<br>E.8<br>0369300000 Q 10 AKZ4SS<br>E.8<br>0369300000 Q 10 AKZ4SS<br>I.11<br>**0370000000**<br>0370000000<br>I.9<br>0370160000 MK 10/14<br>F.3<br>0371420000 SAKS 1/32 G20 LD 24VDC<br>B.22<br>0372600000 H1,0/6<br>J.33<br>0372700000 H1,5/7<br>J.33<br>0373000000 H2,5/7<br>J.33<br>0373100000 H4,0/9<br>J.33<br>0374660000 EK 16<br>B.13<br>0375200000 H16,0/18<br>J.33<br>0375300000 H25,0/18<br>J.33<br>0376860000 ASK 1/15<br>E.6<br>0377100000 KISC M3X20 SAK10 CU5<br>A.33<br>0377100000 KISC M3X20 SAK10 CU5<br>I.12<br>0377100000 KISC M3X20 SAK10 CU5<br>A.32<br>0377100000 KISC M3X20 SAK10 CU5<br>B.31<br>0377100000 KISC M3X20 SAK10 CU5<br>B.32<br>0377100000 KISC M3X20 SAK10 CU5<br>I.21<br>0377200000 KISC M3X15/6 SAK2.5 CU5<br>B.32<br>0377200000 KISC M3X15/6 SAK2.5 CU5<br>I.12<br>0377200000 KISC M3X15/6 SAK2.5 CU5<br>A.33<br>0379300000 H10,0/18<br>J.33<br>0379400000 STB 6/D3.7/2.3/M3 SAKR<br>B.16<br>0379400000 STB 6/D3.7/2.3/M3 SAKR<br>B.18<br>0379400000 STB 6/D3.7/2.3/M3 SAKR<br>B.40<br>0379400000 STB 6/D3.7/2.3/M3 SAKR<br>A.18<br>0379400000 STB 6/D3.7/2.3/M3 SAKR<br>I.15<br>**0380000000**<br>0380260000 AKE 4<br>E.5<br>0380350000 AP ASK1 RT<br>I.6<br>0380360000 AP ASK1<br>C.7<br>0380360000 AP ASK1<br>I.6<br>0380380000 AP ASK1 BL<br>I.6<br>0380420000 SAK 2.5/35 KRG<br>A.7<br>0380440000 SAK 2.5/35 OR<br>I.7<br>0380460000 SAK 2.5/35<br>A.2<br>0380470000 SAK 2.5/35 KRG/BL<br>A.7<br>0380470000 SAK 2.5/35 KRG/BL<br>I.7<br>0380480000 SAK 2.5/35 BL<br>A.2<br>0380480000 SAK 2.5/35 BL<br>I.7<br>0380520000 SAK 6/35 KRG<br>A.8<br>0380560000 SAK 6/35 PA<br>A.3<br>0380570000 SAK 6/35 KRG/BL<br>A.8<br>0380570000 SAK 6/35 KRG/BL<br>I.7<br>0380580000 SAK 6/35 PA/BL<br>I.7<br>0380580000 SAK 6/35 PA/BL<br>A.3<br>0380620000 SAK 16/35 KRG<br>A.9<br>0380660000 SAK 16/35 PA<br>A.4<br>0380680000 SAK 16/35 PA/BL<br>I.7<br>0380680000 SAK 16/35 PA/BL<br>A.4<br>0380760000 SAK 35/35<br>A.4<br>0380780000 SAK 35/35 BL<br>A.4<br>0380780000 SAK 35/35 BL<br>I.7<br>0382860000 EW 15<br>H.13<br>0382860000 EW 15<br>E.3<br>0382860000 EW 15<br>E.2<br>0383400000 TS 35X7.5 2M/ST/ZN<br>H.11<br>0383410000 TS 35X7.5 1M/ST/ZN<br>H.11<br>0383530000 EW 35 GR 7032<br>H.13<br>0383560000 EW 35<br>A.56<br>0383560000 EW 35<br>C.8<br>0383560000 EW 35<br>H.13<br>0383560000 EW 35<br>A.57<br>0385320000 SAKS 1/32 G20 GL 115VAC<br>B.22<br>0385400000 STB 16/D7/4/M5 SAK70<br>A.10<br>0385400000 STB 16/D7/4/M5 SAK70<br>I.15<br>0385400000 STB 16/D7/4/M5 SAK70<br>B.9<br>0385400000 STB 16/D7/4/M5 SAK70<br>A.6<br>0386060000 IH 2.8 DB<br>A.37<br>0386060000 IH 2.8 DB<br>A.36<br>0386060000 IH 2.8 DB<br>B.37<br>0386060000 IH 2.8 DB<br>E.8<br>0386060000 IH 2.8 DB<br>B.42<br>0386060000 IH 2.8 DB<br>E.9<br>0386060000 IH 2.8 DB<br>B.43<br>0386060000 IH 2.8 DB<br>B.44<br>0386060000 IH 2.8 DB<br>B.36<br>0386060000 IH 2.8 DB<br>A.38|**Order No.**<br>**Type**<br>**Page**<br>0386060000 IH 2.8 DB<br>A.39<br>0386260000 IH 6.3 WEM GE<br>B.37<br>0386260000 IH 6.3 WEM GE<br>A.38<br>0386260000 IH 6.3 WEM GE<br>B.36<br>0386260000 IH 6.3 WEM GE<br>E.9<br>0386260000 IH 6.3 WEM GE<br>B.43<br>0386260000 IH 6.3 WEM GE<br>A.36<br>0386260000 IH 6.3 WEM GE<br>A.39<br>0386260000 IH 6.3 WEM GE<br>B.44<br>0386260000 IH 6.3 WEM GE<br>E.8<br>0386260000 IH 6.3 WEM GE<br>A.37<br>0386260000 IH 6.3 WEM GE<br>B.42<br>0388500000 STB 35 IH/SW<br>I.20<br>0388500000 STB 35 IH/SW<br>I.15<br>0388600000 STB 35 IH/GR<br>I.20<br>0388600000 STB 35 IH/GR<br>I.15<br>0388700000 STB 35 IH/BL<br>I.20<br>0388700000 STB 35 IH/BL<br>I.15<br>0388800000 STB 35 IH/RT<br>I.15<br>0388800000 STB 35 IH/RT<br>I.20<br>0388900000 STB 35 IH/GN<br>I.20<br>0388900000 STB 35 IH/GN<br>I.15<br>0389000000 STB 35 IH/GE<br>I.15<br>0389000000 STB 35 IH/GE<br>I.20<br>0389100000 STB 35 IH/VI<br>I.20<br>0389100000 STB 35 IH/VI<br>I.15<br>**0390000000**<br>0395460000 DK 4/35 LD GR 24VDC<br>A.50<br>0395760000 DK 4/35 LD GR 24VDC<br>A.50<br>0395960000 DK 4/35 LD 1D ROT 24VAC<br>A.51<br>0396360000 DK 4/35 1D GET.SCH.<br>A.53<br>0396660000 DK 4/35 2D GET.SCH. A1<br>A.54<br>0396760000 DK 4/35 2D GET.SCH. A1<br>A.55<br>0396860000 DK 4/35 2D GET.SCH. A2<br>A.55<br>0396960000 DK 4/35 1D 1K5 GET.SCH<br>A.55<br>**0400000000**<br>0400100000 KISC M2.5X11/4.5 AKZ1.5<br>I.9<br>0401220000 SAK 4 S 6.3/2.8/KRG<br>B.44<br>0401260000 SAK 4 S 6.3/2.8<br>B.37<br>0401360000 AP DUSA4/35<br>I.6<br>0401460000 SO SH1<br>H.4<br>0407360001 DEK 6,5 FSZ 1-10<br>K.9<br>0407360011 DEK 6,5 FSZ 11-20<br>K.9<br>0407360021 DEK 6,5 FSZ 21-30<br>K.9<br>0407360031 DEK 6,5 FSZ 31-40<br>K.9<br>0407360041 DEK 6,5 FSZ 41-50<br>K.9<br>0407360051 DEK 6,5 FSZ 51-60<br>K.9<br>0407360061 DEK 6,5 FSZ 61-70<br>K.9<br>0407360071 DEK 6,5 FSZ 71-80<br>K.9<br>0407360081 DEK 6,5 FSZ 81-90<br>K.9<br>0407360091 DEK 6,5 FSZ 91-100<br>K.9<br>0407600000 QL 3 SAKG28<br>B.46<br>0407600000 QL 3 SAKG28<br>I.9<br>0407600000 QL 3 SAKG28<br>B.47<br>0407600000 QL 3 SAKG28<br>A.10<br>0407600000 QL 3 SAKG28<br>B.9<br>0407700000 QL 4 SAKG28<br>B.47<br>0407700000 QL 4 SAKG28<br>I.9<br>0407700000 QL 4 SAKG28<br>A.10<br>0407700000 QL 4 SAKG28<br>B.46<br>0407700000 QL 4 SAKG28<br>B.9<br>0407900000 IS 6 DIN 6911<br>J.20<br>0408000000 QL 3 SAKG54<br>B.53<br>0408000000 QL 3 SAKG54<br>A.47<br>0408730000 AP SAKH 4EX<br>I.6<br>0409500000 H0,5/12 OR<br>J.22<br>0409600000 H0,75/12 W<br>J.22<br>0409700000 H1,0/12 GE<br>J.22<br>0409800000 QL 4 SAKG40<br>B.50<br>0409800000 QL 4 SAKG40<br>B.51<br>**0410000000**<br>0412120000 SAKR KRG<br>B.18<br>0412160000 SAKR<br>B.16<br>0412180000 SAKR BL<br>I.7<br>0412180000 SAKR BL<br>B.16<br>0412220000 SAKR 2STB KRG<br>B.18<br>0412260000 SAKR 2STB<br>B.16<br>0412280000 SAKR 2STB BL<br>B.16<br>0412280000 SAKR 2STB BL<br>I.7<br>0412760000 SAKR 15<br>E.3<br>0412860000 SAKR 15 2STB<br>E.3<br>**0430000000**<br>0430300000 G 20/0.10A/F<br>B.26<br>0430300000 G 20/0.10A/F<br>A.23<br>0430300000 G 20/0.10A/F<br>A.22<br>0430300000 G 20/0.10A/F<br>B.20<br>0430300000 G 20/0.10A/F<br>B.21<br>0430300000 G 20/0.10A/F<br>A.28<br>0430400000 G 20/0.20A/F<br>A.28<br>0430400000 G 20/0.20A/F<br>A.23<br>0430400000 G 20/0.20A/F<br>B.26<br>0430400000 G 20/0.20A/F<br>A.22|
|---|---|---|
**X.19**
**X**
|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|0443780000|SAK 10/35 BL|I.7|0457300000|Q 4 SAK10|B.3|0468160801|DEK 6,5 FW 801-850|K.9|0473391692|DEK 5 BR NEUTRAL|K.7|
|0444200000|H50/36 OLIV|J.22|0457300000|Q 4 SAK10|A.8|0468160851|DEK 6,5 FW 851-900|K.9|0473391693|DEK 5 BL NEUTRAL|K.7|
|0444400000|QL 3 SAKG46|A.46|0457400000|Q 10 SAK10|I.9|0468160901|DEK 6,5 FW 901-950|K.9|0473391694|DEK 5 SW NEUTRAL|K.8|
|0444400000|QL 3 SAKG46|B.52|0457400000|Q 10 SAK10|C.3|0468160951|DEK 6,5 FW 951-999|K.9|0473460001|DEK 5 FW 1-50|K.7|
|0444400000|QL 3 SAKG46|A.47|0457400000|Q 10 SAK10|A.3|0468260001|DEK 6,5 FS 1-50|K.9|0473460051|DEK 5 FW 51-100|K.7|
|0444500000|QL 4 SAKG46|A.46|0457400000|Q 10 SAK10|A.8|0468260051|DEK 6,5 FS 51-100|K.9|0473460101|DEK 5 FW 101-150|K.7|
|0444500000|QL 4 SAKG46|B.52|0457400000|Q 10 SAK10|B.3|0468260101|DEK 6,5 FS 101-150|K.9|0473460151|DEK 5 FW 151-200|K.7|
|0444500000|QL 4 SAKG46|A.47|0457400000|Q 10 SAK10|B.7|0468260151|DEK 6,5 FS 151-200|K.9|0473460201|DEK 5 FW 201-250|K.7|
|0444900000<br>0445000000<br>0445420000<br>0445860000|QL 3 SAKG40/35<br>QL 4 SAKG40/35<br>SAKT 2/LT O.STB<br>AKZ 4 SW 1X1|A.45<br>A.45<br>B.32<br>E.13|0457500000<br>0457500000<br>0457500000<br>0457500000|Q 2 SAK16<br>Q 2 SAK16<br>Q 2 SAK16<br>Q 2 SAK16|B.4<br>C.3<br>A.9<br>A.4|0468260201<br>0468260251<br>0468260301<br>0468260351|DEK 6,5 FS 201-250<br>DEK 6,5 FS 251-300<br>DEK 6,5 FS 301-350<br>DEK 6,5 FS 351-400|K.9<br>K.9<br>K.9<br>K.9|0473460251<br>0473460301<br>0473460351<br>0473460401|DEK 5 FW 251-300<br>DEK 5 FW 301-350<br>DEK 5 FW 351-400<br>DEK 5 FW 401-450|K.7<br>K.7<br>K.7<br>K.7|
|0446100000|SBL/1912|A.22|0457500000|Q 2 SAK16|B.7|0468260401|DEK 6,5 FS 401-450|K.9|0473460451|DEK 5 FW 451-500|K.7|
|0446100000|SBL/1912|B.20|0457500000|Q 2 SAK16|I.9|0468260451|DEK 6,5 FS 451-500|K.9|0473460501|DEK 5 FW 501-550|K.7|
|0446200000|SBL/2111|B.20|0457600000|Q 3 SAK16|B.4|0468260501|DEK 6,5 FS 501-550|K.9|0473460551|DEK 5 FW 551-600|K.7|
|0446200000|SBL/2111|A.22|0457600000|Q 3 SAK16|A.9|0468260551|DEK 6,5 FS 551-600|K.9|0473460601|DEK 5 FW 601-650|K.7|
|0446300000|SBL/2489|A.23|0457600000|Q 3 SAK16|C.3|0468260601|DEK 6,5 FS 601-650|K.9|0473460651|DEK 5 FW 651-700|K.7|
|0446600000|VH 10/4/2.8 AKZ4|A.52|0457600000|Q 3 SAK16|B.7|0468260651|DEK 6,5 FS 651-700|K.9|0473460701|DEK 5 FW 701-750|K.7|
|0446600000|VH 10/4/2.8 AKZ4|E.11|0457600000|Q 3 SAK16|I.9|0468260701|DEK 6,5 FS 701-750|K.9|0473460751|DEK 5 FW 751-800|K.7|
|0446600000|VH 10/4/2.8 AKZ4|B.57|0457600000|Q 3 SAK16|A.4|0468260751|DEK 6,5 FS 751-800|K.9|0473460801|DEK 5 FW 801-850|K.7|
|0446600000|VH 10/4/2.8 AKZ4|B.60|0457700000|Q 4 SAK16|B.4|0468260801|DEK 6,5 FS 801-850|K.9|0473460851|DEK 5 FW 851-900|K.7|
|0446600000|VH 10/4/2.8 AKZ4|A.53|0457700000|Q 4 SAK16|I.9|0468260851|DEK 6,5 FS 851-900|K.9|0473460901|DEK 5 FW 901-950|K.7|
|0446600000|VH 10/4/2.8 AKZ4|B.58|0457700000|Q 4 SAK16|A.4|0468260901|DEK 6,5 FS 901-950|K.9|0473460951|DEK 5 FW 951-999|K.7|
|0446600000|VH 10/4/2.8 AKZ4|A.51|0457700000|Q 4 SAK16|C.3|0468260951|DEK 6,5 FS 951-999|K.9|0473560001|DEK 5 FS 1-50|K.7|
|0446600000|VH 10/4/2.8 AKZ4|E.10|0457700000|Q 4 SAK16|A.9|0468560000|DEK 6 NEUTRAL|K.8|0473560051|DEK 5 FS 51-100|K.7|
|0446600000|VH 10/4/2.8 AKZ4|A.56|0457700000|Q 4 SAK16|B.7|0468560000|DEK 6 NEUTRAL|K.9|0473560101|DEK 5 FS 101-150|K.7|
|0446600000|VH 10/4/2.8 AKZ4|A.55|0457800000|Q 10 SAK16|A.9|0468591686|DEK 6 RT NEUTRAL|K.9|0473560151|DEK 5 FS 151-200|K.7|
|0446600000|VH 10/4/2.8 AKZ4|E.12|0457800000|Q 10 SAK16|I.9|0468591687|DEK 6 GE NEUTRAL|K.8|0473560201|DEK 5 FS 201-250|K.7|
|0446600000|VH 10/4/2.8 AKZ4|B.56|0457800000|Q 10 SAK16|C.3|0468591688|DEK 6 GN NEUTRAL|K.8|0473560251|DEK 5 FS 251-300|K.7|
|0446600000|VH 10/4/2.8 AKZ4|A.50|0457800000|Q 10 SAK16|A.4|0468591689|DEK 6 VI NEUTRAL|K.9|0473560301|DEK 5 FS 301-350|K.7|
|0446600000|VH 10/4/2.8 AKZ4|A.54|0457800000|Q 10 SAK16|B.4|0468591690|DEK 6 OR NEUTRAL|K.9|0473560351|DEK 5 FS 351-400|K.7|
|0446600000|VH 10/4/2.8 AKZ4|B.59|0457800000|Q 10 SAK16|B.7|0468591691|DEK 6 GR NEUTRAL|K.8|0473560401|DEK 5 FS 401-450|K.7|
|0446700000|VL 2 AKZ4/DK4|A.54|0459500000|ZBE 6|H.6|0468591692|DEK 6 BR NEUTRAL|K.8|0473560451|DEK 5 FS 451-500|K.7|
|0446700000|VL 2 AKZ4/DK4|E.11||||0468591693|DEK 6 BL NEUTRAL|K.8|0473560501|DEK 5 FS 501-550|K.7|
|0446700000<br>0446700000|VL 2 AKZ4/DK4<br>VL 2 AKZ4/DK4|E.10<br>B.60|**0460000000**|||0468591694<br>0468660001|DEK 6 SW NEUTRAL<br>DEK 6 FW 1-50|K.9<br>K.8|0473560551<br>0473560601|DEK 5 FS 551-600<br>DEK 5 FS 601-650|K.7<br>K.7|
|0446700000|VL 2 AKZ4/DK4|E.12|0460020000|AP SAK4 KRG M.FU|I.6|0468660051|DEK 6 FW 51-100|K.8|0473560651|DEK 5 FS 651-700|K.7|
|0446700000|VL 2 AKZ4/DK4|A.56|0460360000|AST 3/35 6.3/2.8|A.36|0468660101|DEK 6 FW 101-150|K.8|0473560701|DEK 5 FS 701-750|K.7|
|0446700000|VL 2 AKZ4/DK4|A.55|0460460000|AST 4/35 SF 6.3/2.8|A.37|0468660151|DEK 6 FW 151-200|K.8|0473560751|DEK 5 FS 751-800|K.7|
|0446700000|VL 2 AKZ4/DK4|A.50|0460490000|AP SAK2.5/35 DB|I.6|0468660201|DEK 6 FW 201-250|K.8|0473560801|DEK 5 FS 801-850|K.7|
|0446700000|VL 2 AKZ4/DK4|B.59|0460560000|AP SAK2.5/35 + AST3+4|C.2|0468660251|DEK 6 FW 251-300|K.8|0473560851|DEK 5 FS 851-900|K.7|
|0446700000|VL 2 AKZ4/DK4|B.56|0460560000|AP SAK2.5/35 + AST3+4|A.37|0468660301|DEK 6 FW 301-350|K.8|0473560901|DEK 5 FS 901-950|K.7|
|0446700000|VL 2 AKZ4/DK4|A.51|0460560000|AP SAK2.5/35 + AST3+4|B.36|0468660351|DEK 6 FW 351-400|K.8|0473560951|DEK 5 FS 951-999|K.7|
|0446700000|VL 2 AKZ4/DK4|A.53|0460560000|AP SAK2.5/35 + AST3+4|I.6|0468660401|DEK 6 FW 401-450|K.8|0474360000|EK 2.5N|B.12|
|0446700000|VL 2 AKZ4/DK4|B.57|0460580000|AP SAK2.5/35 BL|I.6|0468660451|DEK 6 FW 451-500|K.8|0474460000|DK 4/32 LD ROT 24VDC A2|B.56|
|0446700000|VL 2 AKZ4/DK4|B.58|0460660001|DEK 5 FSZ 1-10|K.7|0468660501|DEK 6 FW 501-550|K.8|0474560000|ASK 1/EN|C.7|
|0446700000|VL 2 AKZ4/DK4|A.52|0460660011|DEK 5 FSZ 11-20|K.7|0468660551|DEK 6 FW 551-600|K.8|0474700000|TW AST1/PA HP/DBR/0.5|A.11|
|0447240000|AP ST5 PPO/SW|I.6|0460660021|DEK 5 FSZ 21-30|K.7|0468660601|DEK 6 FW 601-650|K.8|0474700000|TW AST1/PA HP/DBR/0.5|B.28|
|0447240000|AP ST5 PPO/SW|C.6|0460660031|DEK 5 FSZ 31-40|K.7|0468660651|DEK 6 FW 651-700|K.8|0474700000|TW AST1/PA HP/DBR/0.5|A.37|
|0447260000|AP ST5 PA/BE|I.6|0460660041|DEK 5 FSZ 41-50|K.7|0468660701|DEK 6 FW 701-750|K.8|0474700000|TW AST1/PA HP/DBR/0.5|B.41|
|0448360000|ST 5 PA/BE|C.6|0460660051|DEK 5 FSZ 51-60|K.7|0468660751|DEK 6 FW 751-800|K.8|0474700000|TW AST1/PA HP/DBR/0.5|B.32|
|0448460000|STL 5|C.6|0460660061|DEK 5 FSZ 61-70|K.7|0468660801|DEK 6 FW 801-850|K.8|0474700000|TW AST1/PA HP/DBR/0.5|A.33|
||||0460660071|DEK 5 FSZ 71-80|K.7|0468660851|DEK 6 FW 851-900|K.8|0474700000|TW AST1/PA HP/DBR/0.5|B.36|
|**0450000000**|||0460660081<br>0460660091|DEK 5 FSZ 81-90<br>DEK 5 FSZ 91-100|K.7<br>K.7|0468660901<br>0468660951|DEK 6 FW 901-950<br>DEK 6 FW 951-999|K.8<br>K.8|0475360000<br>0475380000|ZB 4K GE/GN<br>ZB 4K BL|H.7<br>H.7|
|0451300000|POSC M3X20 PA/NA|I.17|0461100000|QB 2 WI RA8 IS|E.6|0468760001|DEK 6 FS 1-50|K.8|0475460000|IK 4 GG ZB4|H.6|
|0456700000|Q 2 SAK6N|I.21|0461100000|QB 2 WI RA8 IS|C.7|0468760051|DEK 6 FS 51-100|K.8|0475480000|IK 4 BL ZB4|H.6|
|0456700000|Q 2 SAK6N|I.9|0461100000|QB 2 WI RA8 IS|B.21|0468760101|DEK 6 FS 101-150|K.8|0476260000|AP ADK1|I.6|
|0456700000|Q 2 SAK6N|A.8|0461100000||I.13|0468760151|DEK 6 FS 151-200|K.8|0476260000|AP ADK1|E.11|
|0456700000|Q 2 SAK6N|B.3|0461200000|QB 3 WI RA8 IS|E.6|0468760201|DEK 6 FS 201-250|K.8|0476520000|SAK 35/IK KRG|B.8|
|0456700000|Q 2 SAK6N|C.3|0461200000|QB 3 WI RA8 IS|C.7|0468760251|DEK 6 FS 251-300|K.8|0476560000|SAK 35/IK|B.5|
|0456700000|Q 2 SAK6N|A.3|0461200000|QB 3 WI RA8 IS|B.21|0468760301|DEK 6 FS 301-350|K.8|0477660000|TW ST5 PA/BE|C.6|
|0456700000|Q 2 SAK6N|B.7|0461200000||I.13|0468760351|DEK 6 FS 351-400|K.8|0478220000|AST 1 6.3/2.8 KRG|B.42|
|0456800000|Q 3 SAK6N|B.3|0461300000|QB 4 WI RA8 IS|E.6|0468760401|DEK 6 FS 401-450|K.8|0478260000|AST 1 6.3/2.8|B.36|
|0456800000|Q 3 SAK6N|I.9|0461300000|QB 4 WI RA8 IS|C.7|0468760451|DEK 6 FS 451-500|K.8|0479220000|AST 5 SF 6.3/2.8 KRG|B.43|
|0456800000|Q 3 SAK6N|A.3|0461300000|QB 4 WI RA8 IS|B.21|0468760501|DEK 6 FS 501-550|K.8|0479360000|AST 3/35 6.3|A.36|
|0456800000|Q 3 SAK6N|A.8|0461300000||I.13|0468760551|DEK 6 FS 551-600|K.8|0479460000|AST 4/35 SF 6.3|A.37|
|0456800000|Q 3 SAK6N|B.7|0462900000|H0,75/14 W|J.22|0468760601|DEK 6 FS 601-650|K.8|0479620000|SAK 4 SS 6.3/2.8 KRG|B.44|
|0456800000|Q 3 SAK6N|I.21|0463000000|H1,0/14 GE|J.22|0468760651|DEK 6 FS 651-700|K.8|0479660000|SAK 4 SS 6.3/2.8|B.37|
|0456800000|Q 3 SAK6N|C.3|0463100000|H1,5/14 R|J.22|0468760701|DEK 6 FS 701-750|K.8||||
|0456900000<br>0456900000|Q 4 SAK6N<br>Q 4 SAK6N|A.8<br>I.21|0464460000<br>0467400000|SAKR LL<br>SAK 4/EN OR|B.40<br>I.7|0468760751<br>0468760801|DEK 6 FS 751-800<br>DEK 6 FS 801-850|K.8<br>K.8|**0480000000**|||
|0456900000|Q 4 SAK6N|A.3|0467460000|SAK 4/EN|C.2|0468760851|DEK 6 FS 851-900|K.8|0482700000|QB 2 WI RA6 IS|B.40|
|0456900000|Q 4 SAK6N|B.3|0467480000|SAK 4/EN BL|I.7|0468760901|DEK 6 FS 901-950|K.8|0482700000|QB 2 WI RA6 IS|B.57|
|0456900000|Q 4 SAK6N|B.7|0467480000|SAK 4/EN BL|C.2|0468760951|DEK 6 FS 951-999|K.8|0482700000|QB 2 WI RA6 IS|B.58|
|0456900000|Q 4 SAK6N|C.3|0467960000|DK 4/32 1D CSA A2|B.59|0469360000|SAKR TS SE 1.6|B.39|0482700000|QB 2 WI RA6 IS|A.20|
|0456900000|Q 4 SAK6N|I.9|0468060000|DEK 6,5 NEUTRAL|K.9||||0482700000|QB 2 WI RA6 IS|A.53|
|0457000000<br>0457000000|Q 10 SAK6N<br>Q 10 SAK6N|I.21<br>B.3|0468091686<br>0468091687|DEK 6,5 RT NEUTRAL<br>DEK 6,5 GE NEUTRAL|K.9<br>K.9|**0470000000**|||0482700000<br>0482700000|QB 2 WI RA6 IS<br>QB 2 WI RA6 IS|B.60<br>A.54|
|0457000000|Q 10 SAK6N|C.3|0468091688|DEK 6,5 GN NEUTRAL|K.9|0470300000|QL 2 SAK10|I.10|0482700000|QB 2 WI RA6 IS|B.61|
|0457000000|Q 10 SAK6N|A.3|0468091689|DEK 6,5 VI NEUTRAL|K.9|0470300000|QL 2 SAK10|I.9|0482700000|QB 2 WI RA6 IS|A.51|
|0457000000|Q 10 SAK6N|B.7|0468091690|DEK 6,5 OR NEUTRAL|K.9|0470400000|QL 3 SAK10|I.9|0482700000|QB 2 WI RA6 IS|B.16|
|0457000000|Q 10 SAK6N|I.9|0468091693|DEK 6,5 BL NEUTRAL|K.9|0470500000|QL 4 SAK10|I.9|0482700000|QB 2 WI RA6 IS|B.39|
|0457000000|Q 10 SAK6N|A.8|0468091694|DEK 6,5 SW NEUTRAL|K.9|0470600000|QL 10 SAK10|I.9|0482700000|QB 2 WI RA6 IS|B.38|
|0457100000|Q 2 SAK10|A.8|0468160001|DEK 6,5 FW 1-50|K.9|0470700000|QL 2 SAK16|I.9|0482700000|QB 2 WI RA6 IS|B.56|
|0457100000|Q 2 SAK10|B.7|0468160051|DEK 6,5 FW 51-100|K.9|0470800000|QL 3 SAK16|I.9|0482700000|QB 2 WI RA6 IS|A.56|
|0457100000|Q 2 SAK10|B.3|0468160101|DEK 6,5 FW 101-150|K.9|0470900000|QL 4 SAK16|I.9|0482700000|QB 2 WI RA6 IS|B.59|
|0457100000|Q 2 SAK10|C.3|0468160151|DEK 6,5 FW 151-200|K.9|0471000000|QL 10 SAK16|I.9|0482700000|QB 2 WI RA6 IS|A.52|
|0457100000|Q 2 SAK10|A.3|0468160201|DEK 6,5 FW 201-250|K.9|0471460000|DQS 2 1D PS2,3 AG|I.13|0482700000|QB 2 WI RA6 IS|A.55|
|0457100000|Q 2 SAK10|I.9|0468160251|DEK 6,5 FW 251-300|K.9|0471560000|DQS 2 PS2,3 AG M.BRUECK|I.13|0482700000|QB 2 WI RA6 IS|A.19|
|0457200000|Q 3 SAK10|C.3|0468160301|DEK 6,5 FW 301-350|K.9|0471660000|DQS 2 PS2.3 O.BATE|I.13|0482700000|QB 2 WI RA6 IS|B.17|
|0457200000|Q 3 SAK10|B.7|0468160351|DEK 6,5 FW 351-400|K.9|0471780000|NT 2.5/35 10X3 BL|A.30|0482700000|QB 2 WI RA6 IS|A.18|
|0457200000|Q 3 SAK10|A.8|0468160401|DEK 6,5 FW 401-450|K.9|0471880000|NT 10/35 10X3 BL|A.31|0482700000|QB 2 WI RA6 IS|A.50|
|0457200000|Q 3 SAK10|A.3|0468160451|DEK 6,5 FW 451-500|K.9|0473360000|DEK 5 NEUTRAL|K.8|0482700000||I.13|
|0457200000|Q 3 SAK10|B.3|0468160501|DEK 6,5 FW 501-550|K.9|0473391686|DEK 5 RT NEUTRAL|K.8|0482800000|QB 3 WI RA6 IS|A.19|
|0457200000|Q 3 SAK10|I.9|0468160551|DEK 6,5 FW 551-600|K.9|0473391687|DEK 5 GE NEUTRAL|K.7|0482800000|QB 3 WI RA6 IS|B.57|
|0457300000|Q 4 SAK10|C.3|0468160601|DEK 6,5 FW 601-650|K.9|0473391688|DEK 5 GN NEUTRAL|K.7|0482800000|QB 3 WI RA6 IS|B.61|
|0457300000|Q 4 SAK10|B.7|0468160651|DEK 6,5 FW 651-700|K.9|0473391689|DEK 5 VI NEUTRAL|K.8|0482800000|QB 3 WI RA6 IS|B.39|
|0457300000|Q 4 SAK10|A.3|0468160701|DEK 6,5 FW 701-750|K.9|0473391690|DEK 5 OR NEUTRAL|K.8|0482800000|QB 3 WI RA6 IS|B.60|
|0457300000|Q 4 SAK10|I.9|0468160751|DEK 6,5 FW 751-800|K.9|0473391691|DEK 5 GR NEUTRAL|K.7|0482800000|QB 3 WI RA6 IS|B.56|
**X.20**
|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|0482800000|QB 3 WI RA6 IS|B.16|0514500000|TS 35X7.5/LL 2M/ST/ZN|H.11|0522660052|DEK 5 GW 52|K.7|0522660152|DEK 5 GW 152|K.7|
|0482800000|QB 3 WI RA6 IS|B.38|0514510000|TS 35X7.5/LL 1M/ST/ZN|H.11|0522660053|DEK 5 GW 53|K.7|0522660153|DEK 5 GW 153|K.7|
|0482800000|QB 3 WI RA6 IS|B.17|0514570000|TS 35X7.5/LL/6 2M/ST/ZN|H.11|0522660054|DEK 5 GW 54|K.7|0522660154|DEK 5 GW 154|K.7|
|0482800000|QB 3 WI RA6 IS|A.55|0515300000|STR 7 F.SCHT 7|K.17|0522660055|DEK 5 GW 55|K.7|0522660155|DEK 5 GW 155|K.7|
|0482800000|QB 3 WI RA6 IS|A.20|0515300000|STR 7 F.SCHT 7|K.19|0522660056|DEK 5 GW 56|K.7|0522660156|DEK 5 GW 156|K.7|
|0482800000|QB 3 WI RA6 IS|B.40|0517960000|SCHT 7|K.17|0522660057|DEK 5 GW 57|K.7|0522660157|DEK 5 GW 157|K.7|
|0482800000|QB 3 WI RA6 IS|B.59|0518160000|SAKR LS 2STB|B.40|0522660058|DEK 5 GW 58|K.7|0522660158|DEK 5 GW 158|K.7|
|0482800000|QB 3 WI RA6 IS|A.50|0518200000|AD 4 SAK16|B.7|0522660059|DEK 5 GW 59|K.7|0522660159|DEK 5 GW 159|K.7|
|0482800000<br>0482800000<br>0482800000<br>0482800000|QB 3 WI RA6 IS<br>QB 3 WI RA6 IS<br>QB 3 WI RA6 IS<br>QB 3 WI RA6 IS|A.18<br>A.56<br>B.58<br>A.54|0518200000<br>0518200000<br>0518200000<br>0518200000|AD 4 SAK16<br>AD 4 SAK16<br>AD 4 SAK16<br>AD 4 SAK16|I.17<br>C.3<br>A.4<br>A.9|0522660060<br>0522660061<br>0522660062<br>0522660063|DEK 5 GW 60<br>DEK 5 GW 61<br>DEK 5 GW 62<br>DEK 5 GW 63|K.7<br>K.7<br>K.7<br>K.7|0522660160<br>0522660161<br>0522660162<br>0522660163|DEK 5 GW 160<br>DEK 5 GW 161<br>DEK 5 GW 162<br>DEK 5 GW 163|K.8<br>K.8<br>K.8<br>K.8|
|0482800000|QB 3 WI RA6 IS|A.53|0518960001|DEK 6 FWZ 1-10|K.8|0522660064|DEK 5 GW 64|K.7|0522660164|DEK 5 GW 164|K.8|
|0482800000|QB 3 WI RA6 IS|A.52|0518960011|DEK 6 FWZ 11-20|K.8|0522660065|DEK 5 GW 65|K.7|0522660165|DEK 5 GW 165|K.8|
|0482800000|QB 3 WI RA6 IS|A.51|0518960021|DEK 6 FWZ 21-30|K.8|0522660066|DEK 5 GW 66|K.7|0522660166|DEK 5 GW 166|K.8|
|0482800000||I.13|0518960031|DEK 6 FWZ 31-40|K.8|0522660067|DEK 5 GW 67|K.7|0522660167|DEK 5 GW 167|K.8|
|0482900000|QB 4 WI RA6 IS|A.53|0518960041|DEK 6 FWZ 41-50|K.8|0522660068|DEK 5 GW 68|K.7|0522660168|DEK 5 GW 168|K.8|
|0482900000|QB 4 WI RA6 IS|B.56|0518960051|DEK 6 FWZ 51-60|K.8|0522660069|DEK 5 GW 69|K.7|0522660169|DEK 5 GW 169|K.8|
|0482900000|QB 4 WI RA6 IS|A.54|0518960061|DEK 6 FWZ 61-70|K.8|0522660070|DEK 5 GW 70|K.7|0522660170|DEK 5 GW 170|K.8|
|0482900000|QB 4 WI RA6 IS|B.61|0518960071|DEK 6 FWZ 71-80|K.8|0522660071|DEK 5 GW 71|K.7|0522660171|DEK 5 GW 171|K.8|
|0482900000|QB 4 WI RA6 IS|B.58|0518960081|DEK 6 FWZ 81-90|K.8|0522660072|DEK 5 GW 72|K.7|0522660172|DEK 5 GW 172|K.8|
|0482900000|QB 4 WI RA6 IS|A.55|0518960091|DEK 6 FWZ 91-100|K.8|0522660073|DEK 5 GW 73|K.7|0522660173|DEK 5 GW 173|K.8|
|0482900000|QB 4 WI RA6 IS|B.59|0518960101|DEK 6 FWZ 101-110|K.8|0522660074|DEK 5 GW 74|K.7|0522660174|DEK 5 GW 174|K.8|
|0482900000|QB 4 WI RA6 IS|B.57|0518960111|DEK 6 FWZ 111-120|K.8|0522660075|DEK 5 GW 75|K.7|0522660175|DEK 5 GW 175|K.8|
|0482900000|QB 4 WI RA6 IS|A.52|0518960121|DEK 6 FWZ 121-130|K.8|0522660076|DEK 5 GW 76|K.7|0522660176|DEK 5 GW 176|K.8|
|0482900000|QB 4 WI RA6 IS|B.60|0518960131|DEK 6 FWZ 131-140|K.8|0522660077|DEK 5 GW 77|K.7|0522660177|DEK 5 GW 177|K.8|
|0482900000|QB 4 WI RA6 IS|A.50|0518960141|DEK 6 FWZ 141-150|K.8|0522660078|DEK 5 GW 78|K.7|0522660178|DEK 5 GW 178|K.8|
|0482900000|QB 4 WI RA6 IS|B.16|0518960151|DEK 6 FWZ 151-160|K.8|0522660079|DEK 5 GW 79|K.7|0522660179|DEK 5 GW 179|K.8|
|0482900000|QB 4 WI RA6 IS|B.40|0518960161|DEK 6 FWZ 161-170|K.8|0522660080|DEK 5 GW 80|K.7|0522660180|DEK 5 GW 180|K.8|
|0482900000|QB 4 WI RA6 IS|A.18|0518960171|DEK 6 FWZ 171-180|K.8|0522660081|DEK 5 GW 81|K.7|0522660181|DEK 5 GW 181|K.8|
|0482900000|QB 4 WI RA6 IS|A.51|0518960181|DEK 6 FWZ 181-190|K.8|0522660082|DEK 5 GW 82|K.7|0522660182|DEK 5 GW 182|K.8|
|0482900000|QB 4 WI RA6 IS|B.39|0518960191|DEK 6 FWZ 191-200|K.8|0522660083|DEK 5 GW 83|K.7|0522660183|DEK 5 GW 183|K.8|
|0482900000|QB 4 WI RA6 IS|B.38|0518960201|DEK 6 FWZ 201-210|K.8|0522660084|DEK 5 GW 84|K.7|0522660184|DEK 5 GW 184|K.8|
|0482900000|QB 4 WI RA6 IS|A.19|0519060001|DEK 6,5 FWZ 1-10|K.9|0522660085|DEK 5 GW 85|K.7|0522660185|DEK 5 GW 185|K.8|
|0482900000|QB 4 WI RA6 IS|B.17|0519060011|DEK 6,5 FWZ 11-20|K.9|0522660086|DEK 5 GW 86|K.7|0522660186|DEK 5 GW 186|K.8|
|0482900000|QB 4 WI RA6 IS|A.56|0519060021|DEK 6,5 FWZ 21-30|K.9|0522660087|DEK 5 GW 87|K.7|0522660187|DEK 5 GW 187|K.8|
|0482900000|QB 4 WI RA6 IS|A.20|0519060031|DEK 6,5 FWZ 31-40|K.9|0522660088|DEK 5 GW 88|K.7|0522660188|DEK 5 GW 188|K.8|
|0482900000||I.13|0519060041|DEK 6,5 FWZ 41-50|K.9|0522660089|DEK 5 GW 89|K.7|0522660189|DEK 5 GW 189|K.8|
|0483460000|AP TOP4SF-FF|I.4|0519060051|DEK 6,5 FWZ 51-60|K.9|0522660090|DEK 5 GW 90|K.7|0522660190|DEK 5 GW 190|K.8|
|0483460000|AP TOP4SF-FF|I.6|0519060061|DEK 6,5 FWZ 61-70|K.9|0522660091|DEK 5 GW 91|K.7|0522660191|DEK 5 GW 191|K.8|
|0484060000|DK 4/32 1D CSA A1|B.58|0519060071|DEK 6,5 FWZ 71-80|K.9|0522660092|DEK 5 GW 92|K.7|0522660192|DEK 5 GW 192|K.8|
|0485100000|IS 4 DIN 6911|J.20|0519060081|DEK 6,5 FWZ 81-90|K.9|0522660093|DEK 5 GW 93|K.7|0522660193|DEK 5 GW 193|K.8|
|0485200000|ADP 1/HP1 1M|I.16|0519060091|DEK 6,5 FWZ 91-100|K.9|0522660094|DEK 5 GW 94|K.7|0522660194|DEK 5 GW 194|K.8|
|0485300000|ADP 2/HP2 1M|I.16||||0522660095|DEK 5 GW 95|K.7|0522660195|DEK 5 GW 195|K.8|
|0485300000<br>0485400000|ADP 2/HP2 1M<br>ADP 3/HP3 1M|A.11<br>A.10|**0520000000**|||0522660096<br>0522660097|DEK 5 GW 96<br>DEK 5 GW 97|K.7<br>K.7|0522660196<br>0522660197|DEK 5 GW 196<br>DEK 5 GW 197|K.8<br>K.8|
|0485400000|ADP 3/HP3 1M|I.16|0522361075|DEK 5 GW L1|K.8|0522660098|DEK 5 GW 98|K.7|0522660198|DEK 5 GW 198|K.8|
|0485560000|HP 1 ADP1|I.16|0522361076|DEK 5 GW L2|K.8|0522660099|DEK 5 GW 99|K.7|0522660199|DEK 5 GW 199|K.8|
|0485660000|HP 2 ADP2|I.16|0522361077|DEK 5 GW L3|K.8|0522660100|DEK 5 GW 100|K.7|0522660200|DEK 5 GW 200|K.8|
|0485760000|HP 3 ADP3|I.16|0522660001|DEK 5 GW 1|K.7|0522660101|DEK 5 GW 101|K.7|0522761021|DEK 5 GW A|K.8|
|0485860000|HP 4 ADP3|I.16|0522660002|DEK 5 GW 2|K.7|0522660102|DEK 5 GW 102|K.7|0522761022|DEK 5 GW B|K.8|
||||0522660003|DEK 5 GW 3|K.7|0522660103|DEK 5 GW 103|K.7|0522761023|DEK 5 GW C|K.8|
|**0490000000**|||0522660004<br>0522660005|DEK 5 GW 4<br>DEK 5 GW 5|K.7<br>K.7|0522660104<br>0522660105|DEK 5 GW 104<br>DEK 5 GW 105|K.7<br>K.7|0522761024<br>0522761025|DEK 5 GW D<br>DEK 5 GW E|K.8<br>K.8|
|0492500000|H16,0/12|J.33|0522660006|DEK 5 GW 6|K.7|0522660106|DEK 5 GW 106|K.7|0522761026|DEK 5 GW F|K.8|
|0494820000|SAKT 1/QT2|B.31|0522660007|DEK 5 GW 7|K.7|0522660107|DEK 5 GW 107|K.7|0522761027|DEK 5 GW G|K.8|
|0494920000|SH 2|A.14|0522660008|DEK 5 GW 8|K.7|0522660108|DEK 5 GW 108|K.7|0522761028|DEK 5 GW H|K.8|
|0494920000|SH 2|A.15|0522660009|DEK 5 GW 9|K.7|0522660109|DEK 5 GW 109|K.7|0522761029|DEK 5 GW I|K.8|
|0494920000|SH 2|A.16|0522660010|DEK 5 GW 10|K.7|0522660110|DEK 5 GW 110|K.7|0522761030|DEK 5 GW J|K.8|
|0494920000|SH 2|A.17|0522660011|DEK 5 GW 11|K.7|0522660111|DEK 5 GW 111|K.7|0522761031|DEK 5 GW K|K.8|
|0494920000|SH 2|B.15|0522660012|DEK 5 GW 12|K.7|0522660112|DEK 5 GW 112|K.7|0522761032|DEK 5 GW L|K.8|
|0494920000|SH 2|H.4|0522660013|DEK 5 GW 13|K.7|0522660113|DEK 5 GW 113|K.7|0522761033|DEK 5 GW M|K.8|
|0494920000|SH 2|B.14|0522660014|DEK 5 GW 14|K.7|0522660114|DEK 5 GW 114|K.7|0522761034|DEK 5 GW N|K.8|
|0494920000|SH 2|B.13|0522660015|DEK 5 GW 15|K.7|0522660115|DEK 5 GW 115|K.7|0522761035|DEK 5 GW O|K.8|
|0494920000|SH 2|B.12|0522660016|DEK 5 GW 16|K.7|0522660116|DEK 5 GW 116|K.7|0522761036|DEK 5 GW P|K.8|
|0494920000|SH 2|I.12|0522660017|DEK 5 GW 17|K.7|0522660117|DEK 5 GW 117|K.7|0522761037|DEK 5 GW Q|K.8|
|0495160000|EWK 1 ALT|H.13|0522660018|DEK 5 GW 18|K.7|0522660118|DEK 5 GW 118|K.7|0522761038|DEK 5 GW R|K.8|
|0495360000|DK 4/32 LD ROT 24VDC A1|B.56|0522660019|DEK 5 GW 19|K.7|0522660119|DEK 5 GW 119|K.7|0522761039|DEK 5 GW S|K.8|
|0495660000|MOFU 35|H.15|0522660020|DEK 5 GW 20|K.7|0522660120|DEK 5 GW 120|K.7|0522761040|DEK 5 GW T|K.8|
|0497560000|RSF 3 PA|B.28|0522660021|DEK 5 GW 21|K.7|0522660121|DEK 5 GW 121|K.7|0522761041|DEK 5 GW U|K.8|
|0498000000|TS 35X15/2.3 2M/ST/ZN|H.11|0522660022|DEK 5 GW 22|K.7|0522660122|DEK 5 GW 122|K.7|0522761042|DEK 5 GW V|K.8|
|0499280000|NT 16/35 10X3 BL|A.31|0522660023|DEK 5 GW 23|K.7|0522660123|DEK 5 GW 123|K.7|0522761043|DEK 5 GW W|K.8|
||||0522660024|DEK 5 GW 24|K.7|0522660124|DEK 5 GW 124|K.7|0522761044|DEK 5 GW X|K.8|
|**0500000000**|||0522660025<br>0522660026|DEK 5 GW 25<br>DEK 5 GW 26|K.7<br>K.7|0522660125<br>0522660126|DEK 5 GW 125<br>DEK 5 GW 126|K.7<br>K.7|0522761045<br>0522761046|DEK 5 GW Y<br>DEK 5 GW Z|K.8<br>K.8|
|0501470000|NT 6/35 10X3 KRG/BL|A.30|0522660027|DEK 5 GW 27|K.7|0522660127|DEK 5 GW 127|K.7|0522861047|DEK 5 GW A KLEIN|K.8|
|0501520000|SAKS 1/35/G25|A.25|0522660028|DEK 5 GW 28|K.7|0522660128|DEK 5 GW 128|K.7|0522861048|DEK 5 GW B KLEIN|K.8|
|0501620000|SAKS 1/35/G20|A.24|0522660029|DEK 5 GW 29|K.7|0522660129|DEK 5 GW 129|K.7|0522861049|DEK 5 GW C KLEIN|K.8|
|0501820000|SAKS 4/35|A.26|0522660030|DEK 5 GW 30|K.7|0522660130|DEK 5 GW 130|K.7|0522861050|DEK 5 GW D KLEIN|K.8|
|0502120000|SAKS 5/35|A.27|0522660031|DEK 5 GW 31|K.7|0522660131|DEK 5 GW 131|K.7|0522861051|DEK 5 GW E KLEIN|K.8|
|0502610000|ZB 35K SW M6X16|H.7|0522660032|DEK 5 GW 32|K.7|0522660132|DEK 5 GW 132|K.7|0522861052|DEK 5 GW F KLEIN|K.8|
|0502660000|ZB 35K GE/GN M6X16|H.7|0522660033|DEK 5 GW 33|K.7|0522660133|DEK 5 GW 133|K.7|0522861053|DEK 5 GW G KLEIN|K.8|
|0502680000|ZB 35K BL M6X16|H.7|0522660034|DEK 5 GW 34|K.7|0522660134|DEK 5 GW 134|K.7|0522861054|DEK 5 GW H KLEIN|K.8|
|0502780000|IK 35/ZB35 BL|H.6|0522660035|DEK 5 GW 35|K.7|0522660135|DEK 5 GW 135|K.7|0522861055|DEK 5 GW I KLEIN|K.8|
|0502860000|ZB 16K GE/GN|H.7|0522660036|DEK 5 GW 36|K.7|0522660136|DEK 5 GW 136|K.7|0522861056|DEK 5 GW J KLEIN|K.8|
|0502880000|ZB 16K BL|H.7|0522660037|DEK 5 GW 37|K.7|0522660137|DEK 5 GW 137|K.7|0522861057|DEK 5 GW K KLEIN|K.8|
|0502960000|IK 16/ZB16 GG|H.6|0522660038|DEK 5 GW 38|K.7|0522660138|DEK 5 GW 138|K.7|0522861058|DEK 5 GW L KLEIN|K.8|
|0502980000|IK 16/ZB16 BL|H.6|0522660039|DEK 5 GW 39|K.7|0522660139|DEK 5 GW 139|K.7|0522861059|DEK 5 GW M KLEIN|K.8|
|0503500000|MB M3/M5 CRM|H.15|0522660040|DEK 5 GW 40|K.7|0522660140|DEK 5 GW 140|K.7|0522861060|DEK 5 GW N KLEIN|K.8|
|0508401694|STI Waterproof schwarz|K.24|0522660041|DEK 5 GW 41|K.7|0522660141|DEK 5 GW 141|K.7|0522861061|DEK 5 GW O KLEIN|K.8|
|0508401694|STI Waterproof schwarz|K.25|0522660042|DEK 5 GW 42|K.7|0522660142|DEK 5 GW 142|K.7|0522861062|DEK 5 GW P KLEIN|K.8|
||||0522660043|DEK 5 GW 43|K.7|0522660143|DEK 5 GW 143|K.7|0522861063|DEK 5 GW Q KLEIN|K.8|
|**0510000000**|||0522660044<br>0522660045|DEK 5 GW 44<br>DEK 5 GW 45|K.7<br>K.7|0522660144<br>0522660145|DEK 5 GW 144<br>DEK 5 GW 145|K.7<br>K.7|0522861064<br>0522861065|DEK 5 GW R KLEIN<br>DEK 5 GW S KLEIN|K.8<br>K.8|
|0510300000|G 25/0.50A/M WS|A.28|0522660046|DEK 5 GW 46|K.7|0522660146|DEK 5 GW 146|K.7|0522861066|DEK 5 GW T KLEIN|K.8|
|0510300000|G 25/0.50A/M WS|B.26|0522660047|DEK 5 GW 47|K.7|0522660147|DEK 5 GW 147|K.7|0522861067|DEK 5 GW U KLEIN|K.8|
|0514060000|SAK 2.5/35 SW 1X1|I.7|0522660048|DEK 5 GW 48|K.7|0522660148|DEK 5 GW 148|K.7|0522861068|DEK 5 GW V KLEIN|K.8|
|0514200000|TS 15X5 2M/ST/ZN|H.10|0522660049|DEK 5 GW 49|K.7|0522660149|DEK 5 GW 149|K.7|0522861069|DEK 5 GW W KLEIN|K.8|
|0514300000|TSK 35X15 2M PVC/GR|H.12|0522660050|DEK 5 GW 50|K.7|0522660150|DEK 5 GW 150|K.7|0522861070|DEK 5 GW X KLEIN|K.8|
|0514400000|TS 32X15/LL 2M/ST/ZN|H.10|0522660051|DEK 5 GW 51|K.7|0522660151|DEK 5 GW 151|K.7|0522861071|DEK 5 GW Y KLEIN|K.8|
**X**
**X.21**
**X**
|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|0522861072|DEK 5 GW Z KLEIN|K.8|0526960077|DEK 6 GW 77|K.9|0564900000|QL 2 SAK35N|A.5|0630200000|KISC M5X50/26 SAK95|I.9|
|0523060001|DEK 5 FWZ 1-10|K.7|0526960078|DEK 6 GW 78|K.9|0565000000|QL 3 SAK35N|B.9|0630360000|SAK 4 S/35 6.3/2.8|A.37|
|0523060011|DEK 5 FWZ 11-20|K.7|0526960079|DEK 6 GW 79|K.9|0565000000|QL 3 SAK35N|A.5|0630460000|SAK 4 SS/35 6.3/2.8|A.38|
|0523060021|DEK 5 FWZ 21-30|K.7|0526960080|DEK 6 GW 80|K.9|0565000000|QL 3 SAK35N|I.9|0631260000|DK 4S SF 6.3/2.8|B.37|
|0523060031|DEK 5 FWZ 31-40|K.7|0526960081|DEK 6 GW 81|K.9|0565000000|QL 3 SAK35N|B.5|0631300000|AP DK4Q DB|I.6|
|0523060041|DEK 5 FWZ 41-50|K.7|0526960082|DEK 6 GW 82|K.9|0565000000|QL 3 SAK35N|A.9|0631360000|AP DK4S|I.6|
|0523060051|DEK 5 FWZ 51-60|K.7|0526960083|DEK 6 GW 83|K.9|0565100000|QL 4 SAK35N|B.5|0631360000|AP DK4S|A.38|
|0523060061|DEK 5 FWZ 61-70|K.7|0526960084|DEK 6 GW 84|K.9|0565100000|QL 4 SAK35N|B.9|0631360000|AP DK4S|B.37|
|0523060071<br>0523060081<br>0523060091<br>0523760000|DEK 5 FWZ 71-80<br>DEK 5 FWZ 81-90<br>DEK 5 FWZ 91-100<br>DK 4/32 2D CSA A2|K.7<br>K.7<br>K.7<br>B.59|0526960085<br>0526960086<br>0526960087<br>0526960088|DEK 6 GW 85<br>DEK 6 GW 86<br>DEK 6 GW 87<br>DEK 6 GW 88|K.9<br>K.9<br>K.9<br>K.9|0565100000<br>0565100000<br>0565100000<br>0565200000|QL 4 SAK35N<br>QL 4 SAK35N<br>QL 4 SAK35N<br>QL 10 SAK35N|A.9<br>A.5<br>I.9<br>B.9|0631360000<br>0631380000<br>0631860000<br>0631961187|AP DK4S<br>AP DK4S BL<br>DEK 6 FWZ R,S,T,N,ERDE<br>DEK 6 FWZ L1-PE|A.39<br>I.6<br>K.8<br>K.8|
|0525500000|GZ 1.0A/F|B.26|0526960089|DEK 6 GW 89|K.9|0565200000|QL 10 SAK35N|A.5|0631961203|DEK 6 FWZ L1-ERDE I.KRE|K.8|
|0525500000|GZ 1.0A/F|A.23|0526960090|DEK 6 GW 90|K.9|0565200000|QL 10 SAK35N|B.5|0632060000|DEK 6,5 FWZ R,S,T,N,ERD|K.9|
|0525500000|GZ 1.0A/F|A.28|0526960091|DEK 6 GW 91|K.9|0565200000|QL 10 SAK35N|A.9|0632161187|DEK 6,5 FW L1-PE|K.9|
|0525910000|ZBE 6K SW|H.7|0526960092|DEK 6 GW 92|K.9|0565200000|QL 10 SAK35N|I.9|0632161203|DEK 6,5 FW L1-ERDE I.KR|K.9|
|0525960000|ZBE 6K GE/GN|H.7|0526960093|DEK 6 GW 93|K.9|0565460000|ZB 4/6K GE/GN|H.7|0632560000|DEK 6 FW L,N,PE|K.8|
|0525980000|ZBE 6K BL|H.7|0526960094|DEK 6 GW 94|K.9|0565480000|ZB 4/6K BL|H.7|0634100000|AD 250|I.18|
|0526060000|IK 6 GG ZBE6K|H.6|0526960095|DEK 6 GW 95|K.9|0565600000|H1,5/24 R|J.22|0634300000|HP EK132/2 AD250|I.18|
|0526080000|IK 6 BL ZBE6K|H.6|0526960096|DEK 6 GW 96|K.9|0565700000|H6,0/26 SW|J.22|0635060000|AP DKIT4|I.6|
|0526400000||I.13|0526960097|DEK 6 GW 97|K.9|0565800000|H10,0/28 EB|J.22|0635100000|H1,5/16 R|J.22|
|0526700000|ISPF QB75 SW|I.13|0526960098|DEK 6 GW 98|K.9|0565900000|H16,0/24 GN|J.22|0635960000|KLBUE SH1|H.4|
|0526760000|ISPF QB75 RT|I.13|0526960099|DEK 6 GW 99|K.9|0566000000|H16,0/28 GN|J.22|0636620000|SAKG 70/35 II/GW|A.44|
|0526780000|ISPF QB75 BL|I.13|0526960100|DEK 6 GW 100|K.9|0566700000|BEZ.-KARTE ADP|I.16|0636800000|FM 5/TS35|H.15|
|0526960001|DEK 6 GW 1|K.8|0526960200|DEK 6 GW 200|K.9|0567260000|SAK 2.5/35 LL|A.40|0636900000|FM 6/TS35|H.15|
|0526960002|DEK 6 GW 2|K.8|0526961000|DEK 6 GW 0|K.8|0567300000|PZ 3|J.7|0637120000|SAKG 32/35 I|A.42|
|0526960003|DEK 6 GW 3|K.8|0527660000|DK 4/35|A.12|0567300000|PZ 3|J.35|0637220000|SAKG 32/35 III|A.44|
|0526960004|DEK 6 GW 4|K.8|0527680000|DK 4/35 BL|A.12|0569560000|DK 4/32 GL 100K 115VAC|B.57|0637320000|SAKG 32/35 II|A.43|
|0526960005|DEK 6 GW 5|K.8|0528400000|VL 2 RSF 1+2|B.28|0569660000|ZB 16/6K GE/GN|H.7|0637420000|SAKG 32/35 II/GW|A.43|
|0526960006|DEK 6 GW 6|K.8|||||||0637520000|SAKG 40/35 I|A.45|
|0526960007<br>0526960008|DEK 6 GW 7<br>DEK 6 GW 8|K.8<br>K.8|**0530000000**|||**0570000000**|||0637620000<br>0637720000|SAKG 40/35 III<br>SAKG 40/35 II|A.46<br>A.45|
|0526960009|DEK 6 GW 9|K.8|0531760000|SSP 3 SAKT1|A.33|0571200000|SSCH 6X6X1000 MS/BK|H.3|0637820000|SAKG 40/35 II/GW|A.45|
|0526960010|DEK 6 GW 10|K.8|0531760000|SSP 3 SAKT1|B.31|0571300000|SSCH 6X6X1000 CU/SN|H.3|0637920000|SAKG 46/35 II|A.46|
|0526960011|DEK 6 GW 11|K.8|0531760000|SSP 3 SAKT1|A.32|0576260000|DEK 5 GW|K.7|0638020000|SAKG 46/35 II/GW|A.47|
|0526960012|DEK 6 GW 12|K.8|0531760000|SSP 3 SAKT1|I.20|0576261198|DEK 5 GW +|K.8|0638120000|SAKG 54/35 II|A.47|
|0526960013|DEK 6 GW 13|K.8|0531760000|SSP 3 SAKT1|B.32|0576261199|DEK 5 GW -|K.8|0638220000|SAKG 54/35 II/GW|A.47|
|0526960014|DEK 6 GW 14|K.8|0532960000|AP DSK1.5|I.6|0576261202|DEK 5 GW ERDE|K.8||||
|0526960015<br>0526960016|DEK 6 GW 15<br>DEK 6 GW 16|K.8<br>K.8|0533500000<br>0533800000|H6,0/20 SW<br>GZ 0.5A/F|J.22<br>A.28|0576261203<br>0576261215|DEK 5 GW ERDE I.KR.<br>DEK 5 GW W-STROM|K.8<br>K.8|**0640000000**|||
|0526960017|DEK 6 GW 17|K.8|0533800000|GZ 0.5A/F|B.26|0576291737|DEK 5 GW RT/SW +|K.8|0641720000|SH 2 S|H.4|
|0526960018|DEK 6 GW 18|K.8|0534200000|H10,0/22 EB|J.22|0576291741|DEK 5 GW BL/SW -|K.8|0642600000|FKSC M6X8 D9/SW3|H.14|
|0526960019|DEK 6 GW 19|K.8|0535200000||I.13|0576700000|AD 4 SAK35N|A.9|0642760000|DK 4/32 2D CSA GET.SCH.|B.59|
|0526960020|DEK 6 GW 20|K.8|0535300000|EK 95/35/1ZB BK|A.16|0576700000|AD 4 SAK35N|B.5|0646260000|MOFU 35/LO/1|H.15|
|0526960021|DEK 6 GW 21|K.8|0535860000|TA 1|I.14|0576700000|AD 4 SAK35N|I.17|0646400000|G 25/0.80A/M GR|A.28|
|0526960022|DEK 6 GW 22|K.8|0536560000|DK 4 SW 1X1|B.38|0576700000|AD 4 SAK35N|A.5|0646400000|G 25/0.80A/M GR|B.26|
|0526960023|DEK 6 GW 23|K.8|0537261187|DEK 5 GW PE|K.8|0576700000|AD 4 SAK35N|B.9|0646560000|DK 4/32 LD GR 24VDC A2|B.56|
|0526960024|DEK 6 GW 24|K.8|0537261188|DEK 5 GW PEN|K.8||||0646930000|SAK 4 SS/35 6.3 GR|I.7|
|0526960025<br>0526960026<br>0526960027|DEK 6 GW 25<br>DEK 6 GW 26<br>DEK 6 GW 27|K.8<br>K.8<br>K.8|0537261235<br>0538860000<br>0538960000|DEK 5 GW Mp<br>DK 4/35 1D A2<br>DK 4/35 1D A1|K.8<br>A.54<br>A.53|**0580000000**<br>0582360002 DEK 5 FSZ 2,4,6...16||K.7|**0660000000**|||
|0526960028|DEK 6 GW 28|K.8|0538980000|DK 4/35 1D A1 BL|A.53|0582360018|DEK 5 FSZ 18,20,...32|K.7|0661060000|EK 2.5/35|A.14|
|0526960029|DEK 6 GW 29|K.8||||0582460000|SAK 35/35/IK|A.5|0661160000|EK 4/35|A.14|
|0526960030<br>0526960031|DEK 6 GW 30<br>DEK 6 GW 31|K.8<br>K.8|**0540000000**|||0582560000||I.4|0661260000<br>0661360000|EK 6/35<br>EK 10/35|A.15<br>A.15|
|0526960032<br>0526960033|DEK 6 GW 32<br>DEK 6 GW 33|K.8<br>K.8|0542500000<br>0544120000|H0,75/10<br>SAK 2.5 LS KRG|J.33<br>B.45|**0590000000**|||0661460000<br>0662220000|EK 35/35<br>SAK 95/35 KRG|A.16<br>A.10|
|0526960034|DEK 6 GW 34|K.8|0544660000|DK 4/32 1D CSA GET.SCH.|B.58|0590060000|DK 4Q/32|B.10|0662270000|SAK 95/35 KRG/BL|I.7|
|0526960035|DEK 6 GW 35|K.8|0545300000||I.13|0590080000|DK 4Q/32 BL|B.10|0663960000|DK 4/32 2D A1|B.60|
|0526960036|DEK 6 GW 36|K.8|0545400000||I.13|0590160000|DK 4Q/35|A.12|0664600000|DMS 2 Set|J.11|
|0526960037|DEK 6 GW 37|K.8|0546000000|ISPF QB58 SW|I.13|0590180000|DK 4Q/35 BL|A.12|0664860000|AST 1/35 6.3|A.36|
|0526960038|DEK 6 GW 38|K.8|0546040000|ISPF QB58 RT|I.13|0590260000|DK 4QV/32|B.11|0664960000|AST 5/35 SF 6.3/2.8|A.37|
|0526960039|DEK 6 GW 39|K.8|0546080000|ISPF QB58 BL|I.13|0590280000|DK 4QV/32 BL|B.11|0667520000|SAKS 3/35 GZ/6.3X32|A.25|
|0526960040|DEK 6 GW 40|K.8|0546900000|G 25/0.25A/M GE|B.26|||||||
|0526960041<br>0526960042|DEK 6 GW 41<br>DEK 6 GW 42|K.8<br>K.8|0546900000|G 25/0.25A/M GE|A.28|**0600000000**|||**0680000000**|||
|0526960043<br>0526960044|DEK 6 GW 43<br>DEK 6 GW 44|K.8<br>K.8|**0550000000**|||0607000000<br>0607000000|TW SAKS2 HP/DBR/2<br>TW SAKS2 HP/DBR/2|B.36<br>A.36|0685260000<br>0686660000|DK 4/32 1D 1K5<br>DK 4S/35 SF 6.3/2.8|B.60<br>A.39|
|0526960045|DEK 6 GW 45|K.8|0550420000|SAKT 1/DU2|B.31|0607000000|TW SAKS2 HP/DBR/2|B.40|0687360000|DKT 4|B.17|
|0526960046|DEK 6 GW 46|K.8|0550520000|SAK 95 KRG|B.9|0607000000|TW SAKS2 HP/DBR/2|B.42|0687460000|DKT 4/35|A.19|
|0526960047|DEK 6 GW 47|K.8|0550620000|SAK 35N KRG|B.9|0607000000|TW SAKS2 HP/DBR/2|B.34|0687560000|AP DKT4 PA|B.17|
|0526960048|DEK 6 GW 48|K.8|0550660000|SAK 35N|B.5|0607000000|TW SAKS2 HP/DBR/2|A.34|0687560000|AP DKT4 PA|B.61|
|0526960049|DEK 6 GW 49|K.8|0550920000|AP SAK95 KRG|I.4|0607000000|TW SAKS2 HP/DBR/2|B.43|0687560000|AP DKT4 PA|I.6|
|0526960050|DEK 6 GW 50|K.8|0550920000|AP SAK95 KRG|I.6|0607000000|TW SAKS2 HP/DBR/2|B.17|0687560000|AP DKT4 PA|A.19|
|0526960051|DEK 6 GW 51|K.8|0550920000|AP SAK95 KRG|B.9|0607000000|TW SAKS2 HP/DBR/2|B.38|0687560000|AP DKT4 PA|A.56|
|0526960052|DEK 6 GW 52|K.8|0550920000|AP SAK95 KRG|A.10|0607000000|TW SAKS2 HP/DBR/2|B.39|0687900000|FM 4/TS35|G.10|
|0526960053|DEK 6 GW 53|K.8|0550970000|AP SAK95 KRG/BL|I.6|0607000000|TW SAKS2 HP/DBR/2|B.45|0687900000|FM 4/TS35|H.15|
|0526960054|DEK 6 GW 54|K.8|0550970000|AP SAK95 KRG/BL|A.10|0608220000|SAK 35N/35 KRG|A.9|0688660000|DEK 6 FW 1-5 (10X)|K.8|
|0526960055|DEK 6 GW 55|K.8|0551100000|VH 35/11/5.5 SAK95|I.9|0608260000|SAK 35N/35|A.5||||
|0526960056<br>0526960057|DEK 6 GW 56<br>DEK 6 GW 57|K.8<br>K.8|0551100000<br>0551100000|VH 35/11/5.5 SAK95<br>VH 35/11/5.5 SAK95|B.9<br>A.10|0608320000<br>0608360000|SAK 35N/35/IK KRG<br>SAK 35N/35/IK|A.9<br>A.5|**0690000000**|||
|0526960058|DEK 6 GW 58|K.8|0551200000|QL 2 SAKG28|I.9|0608370000|SAK 35N/35/IK KRG/BL|A.9|0690700000|H0,5/14 OR|J.22|
|0526960059|DEK 6 GW 59|K.8|0551200000|QL 2 SAKG28|A.10||||0692160000|DK 4/32 RC 220R/220NF|B.61|
|0526960060<br>0526960061|DEK 6 GW 60<br>DEK 6 GW 61|K.8<br>K.8|0551200000<br>0551200000|QL 2 SAKG28<br>QL 2 SAKG28|B.47<br>B.9|**0620000000**|||0697160000<br>0697180000|AKZ 2.5<br>AKZ 2.5 BL|E.2<br>E.2|
|0526960062|DEK 6 GW 62|K.8|0551200000|QL 2 SAKG28|B.46|0620120000|MK 6/6|F.3|0697260000|AP AKZ2.5K|E.13|
|0526960063|DEK 6 GW 63|K.8|0553300000|KOHUE ASK1|A.23|0620220000|MK 6/4|F.3|0697260000|AP AKZ2.5K|I.6|
|0526960064|DEK 6 GW 64|K.8|0553400000|MB M5/M3 SW|H.15|0620320000|MK 6/3|F.3|0697360000|AP AKZ2.5|I.6|
|0526960065|DEK 6 GW 65|K.8|0555760000|SAK 35N/IK|B.5|0620420000|MK 6/2|F.3|0697360000|AP AKZ2.5|E.2|
|0526960066|DEK 6 GW 66|K.9|0556660000|SH 3|H.4|0623320000|RSF 2|B.29|0697380000|AP AKZ2.5 BL|I.6|
|0526960067|DEK 6 GW 67|K.9|0556700000|ZB 4/6|H.6|0624720000|BK 2 CRN|F.5|0697380000|AP AKZ2.5 BL|E.2|
|0526960068|DEK 6 GW 68|K.9|0556800000|ZB 16/6|H.6|0624920000|BK 3 CRN|F.5|0699020000|SAKT E/32 2LD 60VAC|B.62|
|0526960069|DEK 6 GW 69|K.9|0558360000|DEK 5 FWZ U,V,W,N,PE|K.7|0625120000|BK 4 CRN|F.5|0699660000|AST 1/35 6.3/2.8|A.36|
|0526960070|DEK 6 GW 70|K.9||||0625220000|BK 6 CRN|F.5||||
|0526960071<br>0526960072|DEK 6 GW 71<br>DEK 6 GW 72|K.9<br>K.9|**0560000000**|||0625320000|BK 12 CRN|F.5|**1000000000**|||
|0526960073<br>0526960074|DEK 6 GW 73<br>DEK 6 GW 74|K.9<br>K.9|0564900000<br>0564900000|QL 2 SAK35N<br>QL 2 SAK35N|I.9<br>A.9|**0630000000**|||1001180001<br>1005710000|PRINTJET PRO 230V<br>PLOTTER PEN 0.50 P-INK|K.22<br>K.25|
|0526960075|DEK 6 GW 75|K.9|0564900000|QL 2 SAK35N|B.5|0630200000|KISC M5X50/26 SAK95|B.9|1005710000|PLOTTER PEN 0.50 P-INK|K.24|
|0526960076|DEK 6 GW 76|K.9|0564900000|QL 2 SAK35N|B.9|0630200000|KISC M5X50/26 SAK95|A.10||||
**X.22**
|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|**1010000000**|||1277060000<br>1277091686|DEK 8 NEUTRAL<br>DEK 8 RT NEUTRAL|K.9<br>K.9|1397160000<br>1397160000|AP DK4Q<br>AP DK4Q|B.34<br>I.6|**1640000000**|||
|1011320000|DEK 5/6 PLUS MC NE WS|K.11|1277091687|DEK 8 GE NEUTRAL|K.9|1397160000|AP DK4Q|A.34|1640740000|WS 8/5 MC NEUTRAL|K.14|
|1011440000|PLOTTERPEN 0,7|K.25|1277091688|DEK 8 GN NEUTRAL|K.9|1397180000|AP DK4Q BL|I.6|1640750000|WS 8/5 MC BEDRUCKT|K.14|
|1011440000|PLOTTERPEN 0,7|K.24|1277091689|DEK 8 VI NEUTRAL|K.9|1397180000|AP DK4Q BL|A.12|1646630000|ZS 15/5 MC NEUTRAL|K.15|
|1011450000|PLOTTER PEN 0.70 P-INK|K.24|1277091690|DEK 8 OR NEUTRAL|K.9|1397180000|AP DK4Q BL|B.10|1646640000|ZS 15/5 MC BEDRUCKT|K.15|
|1011450000|PLOTTER PEN 0.70 P-INK|K.25|1278460000|SCHT 9/4|K.18|1397180000|AP DK4Q BL|B.11||||
|**1020000000**<br>1024050000 PRINTJET PRO 115V<br>1025680000 DEK 5/30 MC SDR||K.22<br>K.11|**1280000000**<br>1284060000 DK 4Q/35/TC TYP J<br>1284160000 DK 4Q/35/TC TYP K||A.34<br>A.34|1397180000 AP DK4Q BL<br>**1400000000**<br>1404520000 SAKC 10/35 1STB4 KRG||A.13<br>A.20|**1650000000**<br>1653340001 DEK 8 FW 1-50 TAMPOPR.<br>1653340051 DEK 8 FW 51-100 TAMPOP.<br>1653350001 DEK 8 FS 1-50 TAMPOPR.||K.9<br>K.9<br>K.9|
|1027040000<br>1027050000<br>1027060000<br>1027070000|PJ PRO TNTK INK K<br>PJ PRO TNTK INK C<br>PJ PRO TNTK INK M<br>PJ PRO TNTK INK Y|K.22<br>K.22<br>K.22<br>K.22|1285660000<br>1286600000<br>1287700000<br>1287860000|DK 4Q/35/TC TYP T<br>TST 2/M5<br>BST 2 BEZEICHNUNGSSTR.<br>TBS 2|A.34<br>H.14<br>I.17<br>I.17|**1430000000**<br>1430760000 ADP 4/1000||I.16|1653350051 DEK 8 FS 51-100 TAMPOP.<br>**1660000000**||K.9|
|1027080000<br>1027090000<br>1027110000|PJ PRO TNTK FL<br>PJ PRO TNTK INK SET BK<br>PJ-PRO TNTK INK SET COL|K.22<br>K.22<br>K.22|1288300000<br>1289660001<br>1289660011<br>1289660021|REINIGUNGSBECHER<br>DEK 8 FSZ 1-10<br>DEK 8 FSZ 11-20<br>DEK 8 FSZ 21-30|K.24<br>K.9<br>K.9<br>K.9|**1440000000**<br>1443000000||I.10|1667700000 WAD 8 SONDERDRUCK<br>**1670000000**||K.18|
|**1050000000**<br>1050760000 WGB 5 ABDG.M.GRUPPENBEZ||K.18|1289660031<br>1289660041<br>1289660051|DEK 8 FSZ 31-40<br>DEK 8 FSZ 41-50<br>DEK 8 FSZ 51-60|K.9<br>K.9<br>K.9|**1460000000**|||1670360000<br>1670370000<br>1670380000|QVSK 2 SAKT1<br>ESO 5 POLY.WEISS A4-BOG.<br>ESO 5 POLY.GELB A4-BOG.|I.20<br>K.17<br>K.17|
|1050960000|WGB 8 ABDG.M.GRUPPENBEZ|K.18|1289660061|DEK 8 FSZ 61-70|K.9|1461960000|SAKR OR|I.7|1670390000|ESO 7 POLY.WEISS A4-BOG.|K.19|
|1053460000<br>1053560000<br>1055960000|WAD 5 M. BL.<br>WAD 8 M. BL.<br>WAD 12 M. BL.|K.18<br>K.18<br>K.18|1289660071<br>1289660081<br>1289660091|DEK 8 FSZ 71-80<br>DEK 8 FSZ 81-90<br>DEK 8 FSZ 91-100|K.9<br>K.9<br>K.9|**1570000000**|||1670390000<br>1670400000<br>1670400000|ESO 7 POLY.WEISS A4-BOG.<br>ESO 7 POLY.GELB A4-BOG.<br>ESO 7 POLY.GELB A4-BOG.|K.17<br>K.17<br>K.19|
|1056060000|WAD 5 NEUTRAL|K.18|1289690000|DEK 8 BEDR./FARBIG|K.9|1572000000|DEK 5 FWZ 1-9|K.7|1678650000|FK 4|I.14|
|1056160000<br>1056260000<br>1058800000|WAD 8 NEUTRAL<br>WAD 12 NEUTRAL<br>WTW EN|K.18<br>K.18<br>A.12|**1300000000**|||**1590000000**|||**1680000000**|||
|1058800000|WTW EN|B.10|1303360000|AKE 2.5|E.4|1592810000|KLBUE 4-13.5|G.4|1686920000|PRINT KIT|K.25|
|1058800000|WTW EN|A.13|1304860000|DKT 4V 2STB|B.17|1595960000|AP DLD2.5/PE|I.6||||
|1058800000<br>1058800000<br>1058800000<br>1059000000|WTW EN<br>WTW EN<br>WTW EN<br>WEW 35/1|A.34<br>B.11<br>B.34<br>H.5|1304960000 DKT 4V/35 2STB<br>**1310000000**||A.19|1596240000<br>1596240000<br>1598080000<br>1598090000|SAKH 35 EP/SW<br>SAKH 35 EP/SW<br>SAKK 4 KER/WS<br>SAKK 10 KER/WS|D.7<br>I.7<br>D.2<br>D.3|**1690000000**<br>1692261001 KLBUE 3-8 SC||G.8|
|**1060000000**|||1312500000<br>1312600000<br>1312700000|Q 2 DLI<br>Q 3 DLI<br>Q 4 DLI|I.11<br>I.11<br>I.11|**1600000000**|||**1710000000**<br>1712311001 KLBUE 4-13.5 SC||G.8|
|1061200000|WEW 35/2|H.13|1313100000|Q 10 DLI|I.11|1600480000|KLBUE 3-8|G.4|1712321001|KLBUE 10-20 SC|G.8|
|1061200000|WEW 35/2|H.5|1313260000|AP DLI2.5|I.6|1600490000|KLBUE 10-20|G.4|1715970000|WSH 3/H/N|G.6|
|1062860000|WAD 27 M. BL.|K.18|1317660000|AP DLD2.5|I.6|1607710000|ESO 5 DIN A4 WEISS BOG.|K.17|1716240000|SAK 4|B.3|
|1062960000|WAD 27 NEUTRAL|K.18|1317680000|AP DLD2.5 BL|I.6|1607720000|ESO 7 A4-BOGEN WEISS|K.17|1716300000|KLBUE 15-32|G.4|
|1067600000|WEW 32/1|H.13|1318061187|DEK 6 GW PE|K.9|1607720000|ESO 7 A4-BOGEN WEISS|K.19|1718341001|KLBUE 15-32 SC|G.8|
|1068700000|WSH 1|G.6|1318061198|DEK 6 GW +|K.9|1609801044|DEK 5/5 MC-10 NEUT. WS|K.11|1718530000|TW KST5-12 RE/NO 160/HM|B.55|
||||1318061199|DEK 6 GW -|K.9|1609801044|DEK 5/5 MC-10 NEUT. WS|K.19|1718530000|TW KST5-12 RE/NO 160/HM|A.49|
|**1070000000**|||1318061202<br>1318061203|DEK 6 GW ERDE<br>DEK 6 GW ERDE I.KR.|K.9<br>K.9|1609801044<br>1609801044|DEK 5/5 MC-10 NEUT. WS<br>DEK 5/5 MC-10 NEUT. WS|K.18<br>K.17|1718530000<br>1718530000|TW KST5-12 RE/NO 160/HM<br>TW KST5-12 RE/NO 160/HM|B.54<br>A.48|
|1071900000|EW 15/2|H.13|1318091737|DEK 6 GW RT/SW +|K.9|1609801044|DEK 5/5 MC-10 NEUT. WS|K.16||||
|1079900000|WSH 4 MT|G.9|1318091741<br>1319260000|DEK 6 GW BL/SW -<br>QVS 2/4 SAKT4|K.9<br>B.32|1609801686<br>1609801687|DEK 5/5 MC-10 NEUT. RT<br>DEK 5/5 MC-10 NEUT. GE|K.11<br>K.11|**1720000000**|||
|**1080000000**|||1319260000<br>1319360000|QVS 2/4 SAKT4<br>SSP 4 SAKT4|A.33<br>I.20|1609801688<br>1609801691|DEK 5/5 MC-10 NEUT. GN<br>DEK 5/5 MC-10 NEUT. GR|K.11<br>K.11|1720620000<br>1723800000|DEK 5/7.5 MC NEUTRAL<br>BS 35II KLBUE HOLDER|K.11<br>G.10|
|1080100000|WSH 5|G.6|1319360000|SSP 4 SAKT4|A.33|1609801693|DEK 5/5 MC-10 NEUT. BL|K.11|1723810000|BS 35II KLBUE3-8|G.10|
|1080200000|WSH 6|G.6|1319360000|SSP 4 SAKT4|B.32|1609810000|DEK 5/5 MC BEDRUCKT|K.11|1723820000|BS 35II/KLBUE 4-13.5|G.10|
|1082400000|BFEH 1/WSH|G.7|1319900000|BFSC M3X22 SAKT4|A.33|1609820000|DEK 5/6 MC NEUTRAL|K.11|1724580000|FM 4.2/TS35|H.15|
|1083100000|WSH 18 MT|G.7|1319900000|BFSC M3X22 SAKT4|B.32|1609830000|DEK 5/6 MC BEDRUCKT|K.11||||
|1083200000<br>1083900000|WSH 19 MT<br>SMSE WSH U1|G.7<br>G.7|**1320000000**|||1609840000<br>1609850000<br>1609860000|DEK 5/6,5 MC NEUTRAL<br>DEK 5/6,5 MC BEDRUCKT<br>WS 12/5 MC NEUTRAL|K.11<br>K.11<br>K.14|**1740000000**<br>1741260001 MC-Mobilo 110V/220V||K.25|
|**1100000000**|||1323660000<br>1326360000|SAK 4/35 OR<br>SAK 2.5 OR|I.7<br>I.7|1609860000<br>1609860000|WS 12/5 MC NEUTRAL<br>WS 12/5 MC NEUTRAL|K.18<br>K.19|1742630000<br>1746130000|BTWZ KLBUE<br>SSCH 10X3X1000 ST/ZN|G.8<br>G.5|
|1104700000|SAKH 10 CUN/EP/SW|D.7|1326660000|DEK 8 SONDERDR.WEISS|K.9|1609870000|WS 12/5 MC BEDRUCKT|K.14|1746130000|SSCH 10X3X1000 ST/ZN|G.7|
||||1326690000|DEK 8 SONDERDR.FARBIG|K.9|1609880000|WS 15/5 MC NEUTRAL|K.14|1746130000|SSCH 10X3X1000 ST/ZN|G.4|
|**1110000000**<br>1111160000 DK 4/35 GL 1D I1,0A||A.52|**1330000000**|||1609890000<br>1609900000<br>1609910000|WS 15/5 MC BEDRUCKT<br>WS 12/6 MC NEUTRAL<br>WS 12/6 MC BEDRUCKT|K.14<br>K.14<br>K.15|1747350000<br>1749151001<br>1749161001|TS 35X7.5 2M/CRN<br>KLBUE CO 3<br>KLBUE CO 4|H.11<br>G.5<br>G.5|
|1111320000|SAKS 1/35 G20 LD 24VAC|A.24|1333100000|H2,5/14S BL|J.32|1609920000|WS 12/6,5 MC NEUTRAL|K.15|1749430000|BS 35II KLBUE3-8/2X2-6|G.10|
||||1333200000|AP TW/SS.../35|I.6|1609930000|WS 12/6,5 MC BEDRUCKT|K.15||||
|**1160000000**<br>1166820000 SAKT E/35 2LD 30VAC||A.57|1338060000<br>1338160000<br>1338260000|DK 4Q/TC TYP J<br>DK 4Q/TC TYP T<br>DK 4Q/TC TYP K|B.34<br>B.34<br>B.34|**1610000000**|||**1750000000**<br>1752131001 KLBUE CO 2||G.5|
||||1338300000|EK 70/35/M.2ZB O.IK|A.17|1610000000|ZS 10/5 MC NEUTRAL|K.15|1752681001|KLBUE 3-8 CPF SS|G.11|
|**1260000000**<br>1261300000 ZB 10 F.10X3/10X5/10X10||H.6|**1350000000**|||1610010000<br>1610020000<br>1610030000|ZS 10/5 MC BEDRUCKT<br>ZS 12/6 MC NEUTRAL<br>ZS 12/6 BEDRUCKT|K.15<br>K.15<br>K.15|1752691001<br>1752701001<br>1752711001|KLBUE 4-13.5 CPF<br>KLBUE 10-20 CPF<br>KLBUE 15-32 CPF|G.11<br>G.11<br>G.11|
|1266380000|HP NT16/10X3|A.31|1358460000|DEK 5 FW 1,3,5,...99|K.7|1610110000|TSTW D 4.3|H.14|1752800000|TW KST5-12 LI/NO 160/HM|A.49|
|1269060000|SCHT 14/6|K.18|1358560000|DEK 5 FW 2,4,...100|K.7|1611930000|ZGB 30|K.19|1752800000|TW KST5-12 LI/NO 160/HM|A.48|
||||1358660000|DEK 6 FW 1,3,5...99|K.8|1615280000|AP MAK2.5|I.6|1752800000|TW KST5-12 LI/NO 160/HM|B.55|
|**1270000000**<br>1272420000 SAKT 4/35/LT O.STB<br>1272520000 SAKT 4/35/LT STB2.0||A.33<br>A.33|1358760000 DEK 6 FW 2,4,...100<br>**1360000000**||K.8|**1630000000**<br>1631350000 ESO 5 DIN A4 GELB BOG.||K.17|1752800000<br>1752950000<br>1753311001<br>1753320000|TW KST5-12 LI/NO 160/HM<br>WSH 20 MT<br>KLBUE CO 1<br>AP ASK1 DB|B.54<br>G.7<br>G.5<br>I.6|
|1276300000|FZS 2/4 RT/80 SAKT4|I.14|1368720000|SAKS 2/35|A.26|1631920000|ESO 5 S DIN A4-BOGEN|K.17|1755081001|KLBUE CO 5|G.5|
|1276960001<br>1276960011<br>1276960021|DEK 8 FWZ 1-10<br>DEK 8 FWZ 11-20<br>DEK 8 FWZ 21-30|K.9<br>K.9<br>K.9|**1370000000**|||1631930000<br>1631940000<br>1633260000|SCHT 5 S<br>STR 5 S F.SCHT 5 S<br>AP VLI1.5|K.17<br>K.17<br>I.6|1755270000<br>1755280001<br>1755280002|DEK 5/3,5 MC NEUTRAL<br>DEK 5/3,5 MC GW 1<br>DEK 5/3,5 MC GW 2|K.11<br>K.8<br>K.8|
|1276960031|DEK 8 FWZ 31-40|K.9|1378160000|ADP 4/300|I.16|1633320000|AP VLI1.5/PE|I.6|1755280003|DEK 5/3,5 MC GW 3|K.8|
|1276960041<br>1276960051<br>1276960061|DEK 8 FWZ 41-50<br>DEK 8 FWZ 51-60<br>DEK 8 FWZ 61-70|K.9<br>K.9<br>K.9|**1380000000**|||1634780000<br>1634780000<br>1635000000|ESO 7 A4-BOGEN GELB<br>ESO 7 A4-BOGEN GELB<br>WS 10/5 MC NEUTRAL|K.17<br>K.19<br>K.16|1755280004<br>1755280005<br>1755280006|DEK 5/3,5 MC GW 4<br>DEK 5/3,5 MC GW 5<br>DEK 5/3,5 MC GW 6|K.8<br>K.8<br>K.8|
|1276960071|DEK 8 FWZ 71-80|K.9|1381600000|EP 1/BW SAKG32/35 HP/DB|I.5|1635000000|WS 10/5 MC NEUTRAL|K.14|1755280007|DEK 5/3,5 MC GW 7|K.8|
|1276960081<br>1276960091<br>1276960101|DEK 8 FWZ 81-90<br>DEK 8 FWZ 91-100<br>DEK 8 FWZ 101-110|K.9<br>K.9<br>K.9|**1390000000**|||1635010000<br>1636510000<br>1636520000|WS 10/5 MC BEDRUCKT<br>ESO 15 BOGEN DIN A4<br>STR 15 F. ZGB 15|K.14<br>K.19<br>K.19|1755280008<br>1755280009<br>1755281000|DEK 5/3,5 MC GW 8<br>DEK 5/3,5 MC GW 9<br>DEK 5/3,5 MC GW 0|K.8<br>K.8<br>K.8|
|1276960111|DEK 8 FWZ 111-120|K.9|1397160000|AP DK4Q|B.11|1636530000|ZGB 15|K.19||||
|1276960121<br>1276960131|DEK 8 FWZ 121-130<br>DEK 8 FWZ 131-140|K.9<br>K.9|1397160000<br>1397160000|AP DK4Q<br>AP DK4Q|A.12<br>A.13||||**1760000000**|||
|1276960141|DEK 8 FWZ 141-150|K.9|1397160000|AP DK4Q|B.10||||1760720000|BS 35/WSH 2|G.7|
**X**
**X.23**
**X**
|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|1762320001<br>1762320011|DEK 5/3,5 MC FSZ 1-10<br>DEK 5/3,5 MC FSZ 11-20|K.8<br>K.8|**1790000000**|||**1920000000**|||7906060000<br>7906080000|BK 3/E<br>BK 4/E|F.6<br>F.6|
|1762320021|DEK 5/3,5 MC FSZ 21-30|K.8|1790060000|WAD 5 Sonderdruck|K.18|1920640000|PLOTTER PEN 0.25 P-INK|K.25|7906090000|BK 6/E|F.6|
|1762320031|DEK 5/3,5 MC FSZ 31-40|K.8|1790080000|AP 110 GR|I.6|1920640000|PLOTTER PEN 0.25 P-INK|K.24|7906100000|BK 12/E|F.6|
|1762320041|DEK 5/3,5 MC FSZ 41-50|K.8|1792000000|WS 10/5 MC Midd. Neutr.|K.16|1920650000|PLOTTER PEN 0.35 P-INK|K.24|7906110000|MK 3/2/E|F.6|
|1762320051|DEK 5/3,5 MC FSZ 51-60|K.8|1792000000|WS 10/5 MC Midd. Neutr.|K.14|1920650000|PLOTTER PEN 0.35 P-INK|K.25|7906120000|MK 3/3/E|F.6|
|1762320061|DEK 5/3,5 MC FSZ 61-70|K.8|1792000000|WS 10/5 MC Midd. Neutr.|K.17|1924310000|MCP AP SF4-6|K.24|7906130000|MK 3/4/E|F.6|
|1762320071|DEK 5/3,5 MC FSZ 71-80|K.8|1792010000|WS 10/5 MC Midd. Sonder|K.14|1924320000|MCP KLEBESTREIFEN|K.24|7906140000|MK 3/5/E|F.6|
|1762320081<br>1762320091<br>1762320101<br>1762320111|DEK 5/3,5 MC FSZ 81-90<br>DEK 5/3,5 MC FSZ 91-100<br>DEK 5/3,5 MC FSZ 101-110<br>DEK 5/3,5 MC FSZ 111-120|K.8<br>K.8<br>K.8<br>K.8|1797460000<br>1799900000<br>1799910000<br>1799920000|Tintenpatrone PrintJet<br>SAK 2.5/35 SW<br>SAK 2.5/35 RT<br>SAK 2.5/35 DBL|K.22<br>I.7<br>I.7<br>I.7|1924330000<br>1924330000<br>1924340000<br>1924340000|P-CLEANER<br>P-CLEANER<br>P-INK<br>P-INK|K.25<br>K.24<br>K.24<br>K.25|7906150000<br>7906160000<br>7906170000<br>7906180000|MK 3/6/E<br>MK 3/7/E<br>MK 3/8/E<br>MK 3/9/E|F.6<br>F.6<br>F.6<br>F.6|
|1762320121|DEK 5/3,5 MC FSZ 121-130|K.8||||1924350000|MCP COVER|K.24|7906190000|MK 3/10/E|F.6|
|1762320131<br>1762320141|DEK 5/3,5 MC FSZ 131-140<br>DEK 5/3,5 MC FSZ 141-150|K.8<br>K.8|**1800000000**|||1924360000<br>1924370000|MCP AP<br>MCP AP LABLES|K.24<br>K.24|7906200000<br>7906210000|MK 3/11/E<br>MK 3/12/E|F.6<br>F.6|
|1762440000|ADAPTER ALU STI-S|K.25|1802180000|MC-MOBILO AUFN. SF 4-6|K.25|1925000000|MCP PLUS|K.23|7906220000|MK 6/2/E|F.7|
|1762440000|ADAPTER ALU STI-S|K.24|1802690000|TS 27X12.5M/ST/F.ZN|G.11|1927510000|WS 12/5 PLUS MC NEUTRAL|K.14|7906230000|MK 6/3/E|F.7|
|1767090000|SPEEDMARKING-LASER|K.21|1805480000|BZT 2 WS 10/5|K.16|1927520000|WS 12/5 PLUS SONDERDRUCK|K.14|7906240000|MK 6/4/E|F.7|
|1767730000|DEK 5/3,5 MC bedruckt|K.11|1805490000|BZT 1 WS 10/5|K.16|1927530000|WS 12/6 PLUS MC NEUTRAL|K.14|7906250000|MK 6/5/E|F.7|
|1768020000|BS 35II KLBUE2X3-8/2X2-6|G.10|1805520000|BZT 1 ZA WS 10/5|K.16|1927540000|WS 12/6 PLUS SONDERDRUCK|K.15|7906260000|MK 6/6/E|F.7|
|1768090000<br>1768540000<br>1768540000|WS 14/5 MC NEUTRAL<br>Plotterpen 0,25<br>Plotterpen 0,25|K.14<br>K.25<br>K.24|1805530000<br>1805880000<br>1805980000|BZT 2 ZA WS 10/5<br>Snap Mark I<br>TS 35X15/6X18 2M/ST/ZN|K.16<br>K.16<br>H.11|**1930000000**|||**7910000000**|||
|1768550000|Plotterpen 0,35|K.25|1806120000|EM 8/30|K.19|1935130000|MCP EP|K.24|7917000000|AP MAK2.5 DB|I.6|
|1768550000<br>1768560000<br>1768560000|Plotterpen 0,35<br>Plotterpen 0,5<br>Plotterpen 0,5|K.24<br>K.25<br>K.24|1806630000<br>1806650000<br>1806660000|IS 2 KG<br>IS 3 KG<br>IS 4 KG|J.20<br>J.20<br>J.20|**1950000000**|||**7920000000**|||
|1768570000|Plotterpen 0,18|K.25||||1951870000|WS 8/5 PLUS MC NEUTRAL|K.14|7920340000|ZEW 15|H.13|
|1768570000 Plotterpen 0,18<br>**1770000000**||K.24|**1810000000**<br>1814660000 ZF 4 S BL<br>1814670000 ZF 4 S GN||H.7<br>H.7|1951880000<br>1951920000<br>1951920000|WS 8/6 PLUS MC NEUTRAL<br>DEK 5/30 MC NEUTRAL<br>DEK 5/30 MC NEUTRAL|K.14<br>K.18<br>K.11|**8010000000**<br>8014720000 DKT 4/35 PT100||A.56|
|1770070000<br>1770490000<br>1772120000<br>1772120000|TONER SMARK LASER<br>DEK 5/7.5 MC SONDERDR.<br>Tinte 2000 25ml<br>Tinte 2000 25ml|K.21<br>K.11<br>K.25<br>K.24|1814680000<br>1817780000<br>1817860000<br>1818400000|ZF 4 S<br>SAK 4 BL RS-SET<br>SAK 2.5 BL RS-SET<br>WS 10/6 MC Midd. Neutr.|H.7<br>I.7<br>I.7<br>K.14|**2010000000**<br>2012770000 AP STA2.5 0.5MM<br>2012790000 SK E14 SAKS4 USA||I.6<br>B.25|8014730000 DKT 4/32 PT100<br>**8060000000**||B.61|
|1772130000|Reiniger 2000 25ml|K.24|1818410000|WS 10/6 MC Midd. Sonder|K.15|2012790000|SK E14 SAKS4 USA|A.27|8068330000|SAKS 1/35 G20 GL 115VAC|A.24|
|1772130000|Reiniger 2000 25ml|K.25||||||||||
|1772810000<br>1772820000|SAK 6/EN OR<br>SAK 6/EN GE|I.7<br>I.7|**1820000000**|||**2030000000**|||**8100000000**|||
|1772830000|SAK 10/EN OR|I.7|1820200000|AP SAKR BE RS-SET|I.6|2038000000||F.6|8109130000|SAKA 10/EN 2GL 230VAC|C.8|
|1773330001<br>1773330011<br>1773330021<br>1773330031|WS 12/5 FWZ 1-10<br>WS 12/5 FWZ 11-20<br>WS 12/5 FWZ 21-30<br>WS 12/5 FWZ 31-40|K.9<br>K.9<br>K.9<br>K.9|1821480000<br>1828450000<br>1828460000|SAK 2.5/35 GE<br>WS 10/6 MC NEUTRAL<br>WS 10/6 MC Sonderdruck|I.7<br>K.14<br>K.15|2038000000<br>**2070000000**||F.5|**8140000000**<br>8142840000 KDKS1/EN LD 115VAC||C.7|
|1773330041<br>1773340000|WS 12/5 FWZ 41-50<br>SAK 4/EN WS|K.9<br>I.7|**1830000000**|||2076890000<br>2076900000|AP SAK4-10 GE<br>AP SAK16 GE|I.6<br>I.6|8146450000<br>8148910000|KDKS1/EN LD 24VDC<br>KDKS1/EN LD 230VAC|C.7<br>C.7|
|1773350000|SAK 6/EN WS|I.7|1837380000|TS 35X15/LL/5 2M/ST/ZN|H.11|2076910000|AP SAK35/TW SAK16 GE|I.6|8148920000|KDKS1/EN LD 48 VAC|C.7|
|1773360000|WS 8/5 Sonderdr. Laser|K.9||||2077060000|AP AST3+4/35 GE|I.6|8148930000|KDKS1/EN LD 24 VAC|C.7|
|1773370000<br>1773380000<br>1773410000<br>1773430001|WS 10/5 Sonderdr. Laser<br>WS 12/5 Sonderdr. Laser<br>AP 100 GR<br>WS 12/5 FSZ 1-10|K.9<br>K.9<br>I.6<br>K.9|**1840000000**<br>1848290000 TS 35X15/2.3 2M/AL/BK||H.11|2077070000 AP AKZ4 GE<br>**2090000000**||I.6|**8150000000**<br>8150150000 SAKA 10/EN 2GL 24VUC||C.8|
|1773430011<br>1773430021<br>1773430031<br>1773430041|WS 12/5 FSZ 11-20<br>WS 12/5 FSZ 21-30<br>WS 12/5 FSZ 31-40<br>WS 12/5 FSZ 41-50|K.9<br>K.9<br>K.9<br>K.9|**1850000000**<br>1853950000 SAK 4/EN GR 7042<br>1853960000 SAK 10/EN GR RAL 7042||I.7<br>I.7|2093550000<br>**2110000000**||I.6|**8630000000**<br>8630740000 ZEW 35/2||H.13|
|1773521686<br>1773521687<br>1773521690|WS 8/5 MC neutral RT<br>WS 8/5 MC neutral GE<br>WS 8/5 MC neutral OR|K.14<br>K.14<br>K.14|1853970000<br>1854090000<br>1854100000|AP SAK4-10 GR 7042<br>WS 10/15 MC Neutr.<br>WS 10/15 MC Sonderdruck|I.6<br>K.15<br>K.15|2119490000<br>2144900000|AP 2 DSG1.5T<br>AP SAK2.5/35|I.6<br>I.6|**9000000000**|||
|1773521693<br>1773531686|WS 8/5 MC neutral BL<br>WS 10/5 MC neutral RT|K.14<br>K.14|1854490000<br>1854500000|DEK 5/5 PLUS MC NEUTRAL<br>DEK 5/5 PLUS MC SONDERDR.|K.11<br>K.11|**3710000000**|||9002170000<br>9002650000|KT ZQV<br>KT 8|J.3<br>J.2|
|1773531687|WS 10/5 MC neutral GE|K.14|1856740000|DEK 5/8 MC Neutral|K.11|3710000000||I.9|9002660000|KT 12|J.2|
|1773531693|WS 10/5 MC neutral BL|K.14|1856750000|DEK 5/8 MC Sonderdruck|K.11||||9004050000|H0,5/10|J.33|
|1773541686<br>1773541687|WS 12/5 MC neutral RT<br>WS 12/5 MC neutral GE|K.14<br>K.14|1858440000<br>1858450000|SAK 2.5/EN SW<br>SAK 2.5/EN BR|I.7<br>I.7|**3720000000**|||9004060000<br>9004070000|H1,5/12<br>H1,5/18|J.33<br>J.33|
|1773541690|WS 12/5 MC neutral OR|K.14|1858460000|SAK 2.5/EN WS|I.7|3720000000||I.9|9004080000|H2,5/10|J.33|
|1773541693|WS 12/5 MC neutral BL|K.14|1858920000|Tintentank PrintJet II|K.22||||9004090000|H2,5/18|J.33|
|1773551686<br>1773551687|WS 12/6 MC neutral RT<br>WS 12/6 MC neutral GE|K.14<br>K.14|1858950000|CleanUnit PrintJet II|K.22|**3830000000**|||9004100000<br>9004110000|H4,0/15<br>H4,0/18|J.33<br>J.33|
|1773551689<br>1773551690|WS 12/6 MC neutral VI<br>WS 12/6 MC neutral OR|K.14<br>K.14|**1860000000**|||3835020000<br>3835120000|PPT/35<br>AP PPT/35|D.9<br>I.6|9004120000<br>9004130000|H6,0/10<br>H6,0/18|J.33<br>J.33|
|1773551692|WS 12/6 MC neutral BR|K.14|1866290000|TS 35X15/6X25 2M/ST/ZN|H.11|3835120000|AP PPT/35|D.9|9004140000|H1,5/24D SW SV|J.26|
|1773551693|WS 12/6 MC neutral BL|K.14|1866850000|SAK 6/35 GN/GE|I.7||||9004140000|H1,5/24D SW SV|J.24|
|1773561686<br>1773561687<br>1773561688|WS 12/6,5 MC neutral RT<br>WS 12/6,5 MC neutral GE<br>WS 12/6,5 MC neutral GN|K.15<br>K.15<br>K.15|**1900000000**|||**3890000000**<br>3896100000 SP 15||G.9|9004150000<br>9004160000<br>9004170000|H16,0/25<br>H16,0/32<br>H25,0/25|J.33<br>J.33<br>J.33|
|1773561693|WS 12/6,5 MC neutral BL|K.15|1905490000|M-PRINT PRO|K.26|3896200000|SP 20|G.9|9004180000|H25,0/32|J.33|
|1773571687|WS 15/5 MC neutral GE|K.14|1905490000|M-PRINT PRO|K.24|3896300000|SP 30|G.9|9004190000|H35,0/25|J.33|
|1773900000|SAK 10/EN SW|I.7|1905500000|M-PRINT PRO ADVANCED|K.26||||9004200000|H35,0/32|J.33|
|1778270000<br>1778280000|WS 12/3,5 MC neutral<br>WS 12/3,5 MC Sonderdr.|K.14<br>K.14|1905950000<br>1905970000|WS 10/8 MC NEUTRAL<br>WS 10/12 MC NEUTRAL|K.15<br>K.15|**4060000000**|||9004210000<br>9004220000|H50,0/18<br>H50,0/32|J.33<br>J.33|
|1779100000|TSTW 5/M5 ZN|H.14|1906000000|WS 12/8 MC NEUTRAL|K.15|4062150000|PJ-Clean Unit|K.22|9004230000|H70,0/25|J.33|
|**1780000000**|||1906010000<br>1906030000<br>1906060000|WS 12/8 MC SONDERDRUCK<br>WS 10/8 MC SONDERDRUCK<br>WS 10/12 MC SONDERDRUCK|K.15<br>K.15<br>K.15|**4140000000**|||9004240000<br>9004250000<br>9004260000|H70,0/32<br>H95,0/25<br>H95,0/32|J.33<br>J.33<br>J.33|
|1782880000|Magazin SMark Laser|K.21|1907020000|DK 4 QV/EN|C.5|4140450000|AP SAKB/C/T BE|I.6|9004270000|H0,5/14 OR BD|J.23|
|1783550000|AP DLI2.5 DB|I.6|1907030000|DK 4 Q/EN BL|C.4|4145220000|AP RV|I.6|9004280000|H0,5/14D W BD|J.24|
|1783800000|AP DLD2.5/PE DB|I.6|1907040000|DK 4 Q/EN|C.4||||9004280000|H0,5/14D W BD|J.26|
|1784150000<br>1784160000|AP VLI1.5 DB<br>AP VLI1.5/PE DB|I.6<br>I.6|1907520000|DEK 5/5 PLUS MC GE|K.11|**4170000000**|||9004290000<br>9004300000|H0,75/14 W BD<br>H0,75/14D GR BD|J.23<br>J.24|
|1784210000<br>1784390000|AP DLD2.5 DB<br>SAK 16/EN BL|I.6<br>I.7|**1910000000**|||4173520000|AP SAKB/C/T1 DB|I.6|9004310000<br>9004320000|H0,75/14T HBL BD<br>H1,0/14 GE BD|J.26<br>J.23|
|1784390000<br>1784400000|SAK 16/EN BL<br>SAK 35/EN BL|C.3<br>C.4|1917410000<br>1917420000|WS 10/6 MC MIDDLE OR<br>WS 10/6 MC MIDDLE GN|K.14<br>K.14|**6250000000**|||9004330000<br>9004330000|H1,0/14D R BD<br>H1,0/14D R BD|J.26<br>J.24|
|1784400000|SAK 35/EN BL|I.7|1917430000|WS 10/6 MC MIDDLE GE|K.14|6253140000|SAK 2.5 AL BLUE (E)|I.7|9004340000|H1,5/14 R BD|J.23|
|1784410000|SAK 10/EN BL|C.3|1917440000|WS 10/6 MC MIDDLE RT|K.14||||9004350000|H1,5/14D SW BD|J.24|
|1784410000|SAK 10/EN BL|I.7||||**7900000000**|||9004350000<br>9004360000|H1,5/14D SW BD<br>H2,5/14D BL BD|J.26<br>J.23|
|||||||7906040000|BK 2/E|F.6|9004360000|H2,5/14D BL BD|J.24|
**X.24**
|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|**Order No.**|**Type**|**Page**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|9004370000|H2,5/14T GR BD|J.26|9008880000|TH-S 9-40|J.16|9019180000|H2,5/24D BL|J.22|9028290000|H0,75/16 W SV|J.22|
|9004390000|H0,34/12 TK BD GSP|J.23|9008890000|SDIK PZ2|J.14|9019180000|H2,5/24D BL|J.24|9028300000|H0,75/18 W SV|J.22|
|9004410000|H1,5/16 ZH R SV|J.28|9008900000|SDIK PZ1|J.14|9019190000|H4,0/17D GR|J.24|9028310000|H1,0/12 GE SV|J.22|
|9004420000|H1,5/16D ZH SW SV|J.29|9008910000|SDI 1,0x4,5x125|J.14|9019190000|H4,0/17D GR|J.22|9028320000|H1,0/16 GE SV|J.22|
|9004420000|H1,5/16D ZH SW SV|J.30|9008920000|SKI 13,0x125|J.14|9019200000|H4,0/20D GR|J.22|9028340000|H1,0/18 GE SV|J.22|
|9004430000|H2,5/18,5D ZH BL SV|J.28|9008930000|SKI 11,0x125|J.14|9019200000|H4,0/20D GR|J.24|9028350000|H1,5/16 R SV|J.22|
|9004430000|H2,5/18,5D ZH BL SV|J.29|9008940000|SKI 10,0x125|J.14|9019210000|H4,0/26D GR|J.24|9028360000|H1,5/14DS SW SV|J.32|
|9004440000|H0,5/15 ZH OR SV|J.28|9008950000|SKI 9,0x125|J.14|9019210000|H4,0/26D GR|J.22|9028490000|H2,5/12DS BL|J.32|
|9004500000<br>9004510000<br>9004560000<br>9004590000|WAW 1 NEUTRAL<br>WAW 2<br>H0,5/14S OR<br>H0,5/14S W|J.3<br>J.3<br>J.32<br>J.32|9008960000<br>9008970000<br>9008980000<br>9008990000|SKI 8,0x125<br>SKI 7,0x125<br>SKI 6,0x125<br>SKI 5,5x125|J.14<br>J.14<br>J.14<br>J.14|9019220000<br>9019230000<br>9019240000<br>9019250000|H6,0/20D GE<br>H6,0/26D GE<br>H10,0/22D R<br>H10,0/28D R|J.24<br>J.24<br>J.24<br>J.24|**9030000000**<br>9036200000 H2,5/12TS GR||J.32|
|9004710000|H10,0/26D R ZH SV|J.29|9009000000|SKI 5,0x125|J.14|9019260000|H16,0/24D BL|J.24|9036220000|H2,5/16DS BL|J.32|
|9004720000|H6/25D ZH GE SV|J.29|9009010000|SD 1,2x6,5x150|J.15|9019270000|H16,0/28D BL|J.24|9036240000|H120,0/32|J.33|
|9004730000|H4/22D ZH GR SV|J.29|9009020000|SD 0,8x4,5x125|J.15|9019280000|H25,0/30D 16 GE|J.24|9036250000|H150,0/32|J.33|
|9004730000|H4/22D ZH GR SV|J.28|9009030000|SD 0,4x2,5x75|J.15|9019300000|H25,0/36D GE|J.24|9036260000|H185,0/32|J.33|
|9004740000|H2,5/20,5D BL ZH SV|J.29|9009040000|SK 13,0x125|J.15|9019310000|H35,0/30D 16 R|J.24|9037160000|SD 0,4x2,0x60|J.15|
|9004740000|H2,5/20,5D BL ZH SV|J.28|9009050000|SK 12,0x125|J.15|9019320000|H35,0/30D R|J.24|9037200000|H0,5/15 ZH OR|J.30|
|9004750000|H1,5/20D SW ZH SV|J.30|9009060000|SK 11,0x125|J.15|9019330000|H35,0/39D R|J.24|9037200000|H0,5/15 ZH OR|J.28|
|9004750000|H1,5/20D SW ZH SV|J.29|9009070000|SK 10,0x125|J.15|9019340000|H50/36D BL|J.24|9037210000|H0,5/16,5 ZH OR|J.30|
|9004760000|H1,0/20D R ZH SV|J.30|9009080000|SK 9,0x125|J.15|9019350000|H50/40D BL|J.24|9037210000|H0,5/16,5 ZH OR|J.28|
|9004760000|H1,0/20D R ZH SV|J.29|9009090000|SK 8,0x125|J.15|9019400000|H0,5/14D W SV|J.24|9037220000|H0,5/18,5 ZH OR|J.28|
|9004770000|H0,75/17D ZH GR SV|J.29|9009100000|SK 7,0x125|J.15|9019400000|H0,5/14D W SV|J.26|9037220000|H0,5/18,5 ZH OR|J.30|
|9004780000|H0,5/15D ZH W SV|J.29|9009110000|SK 6,0x125|J.15|9019410000|H0,75/14D GR SV|J.24|9037230000|H0,75/15 ZH W|J.28|
|9004900000|H0,75/17 ZH W SV|J.28|9009120000|SK 5,5x125|J.15|9019420000|H1,0/14D R SV|J.26|9037240000|H0,75/17 ZH W|J.28|
|9004910000|H1,0/20 ZH GE SV|J.28|9009140000|SD TH30|J.15|9019420000|H1,0/14D R SV|J.24|9037250000|H0,75/24,5 ZH W|J.28|
|9004920000|H1,5/20 ZH R SV|J.28|9009150000|SD TH25|J.15|9019430000|H1,5/14D SW SV|J.24|9037260000|H1,0/15 ZH GE|J.28|
|9004930000|H6,0/25 ZH SW SV|J.28|9009160000|SD TH20|J.15|9019430000|H1,5/14D SW SV|J.26|9037270000|H1,0/20 ZH GE|J.28|
|9004940000|H10,0/26 ZH EB SV|J.28|9009170000|SD TH15|J.15||||9037280000|H1,0/25,6 ZH GE|J.28|
|9005000000<br>9005140000|STRIPAX<br>H0,75/17T ZH HBL SV|J.4<br>J.30|9009180000<br>9009190000|SD TH10<br>SD TH8|J.15<br>J.15|**9020000000**|||9037290000<br>9037300000|H1,5/16 ZH R<br>H1,5/20 ZH R|J.28<br>J.28|
|9005150000|H2,5/20,5 T ZH GR SV|J.30|9009640000|SDI T10|J.14|9020000000|STRIPAX PLUS 2.5|J.5|9037310000|H1,5/25,6 ZH R|J.28|
|9005160000|H6,0/25T ZH GN SV|J.30|9009650000|SDI T15|J.14|9020000000|STRIPAX PLUS 2.5|J.35|9037320000|H6,0/25 ZH SW|J.28|
|9005170000|H10,0/26T ZH BR SV|J.30|9009660000|SDI T20|J.14|9021010000|H0,25/10T GE|J.26|9037330000|H6,0/29 ZH SW|J.28|
|9005180000|H0,14/10 GR SV|J.22|9009670000|SDI T25|J.14|9021020000|H0,25/12T GE|J.26|9037340000|H10,0/26 ZH EB|J.28|
|9005450000|BUE SPX|J.4|9009680000|SDI T30|J.14|9021030000|H0,75/12T HBL|J.26|9037350000|H10,0/30 ZH EB|J.28|
|9005610000|STRIPAX 16|J.4|9009690000|SDI T40|J.14|9021040000|H0.75/14 HBL|J.26|9037360000|H16,0/29 ZH GN|J.28|
|9005810000|H0,5/14 OR BD GSP|J.23||||9021050000|H0,75/16T HBL|J.26|9037370000|H16,0/38 ZH GN|J.28|
|9005820000<br>9005830000|H0,75/14 W BD GSP<br>H1,0/14 GE BD GSP|J.23<br>J.23|**9010000000**|||9021060000<br>9021070000|H0,75/18T HBL<br>H2,5/14T GR|J.26<br>J.26|9037380000<br>9037390000|H0,5/15D ZH W<br>H0,5/16,5D ZH W|J.29<br>J.29|
|9005840000|H1,5/14 R BD GSP|J.23|9010110000|SD 0,6x3,5x200|J.15|9021080000|H2,5/18T GR|J.26|9037400000|H0,5/18,4D ZH W|J.29|
|9005850000|H2,5/14D BL BD GSP|J.23|9011460000|PZ 6/5|J.35|9021090000|H2,5/24T GR|J.26|9037410000|H0,75/15D ZH GR|J.29|
|9005850000|H2,5/14D BL BD GSP|J.25|9011460000|PZ 6/5|J.6|9021100000|H4,0/17T OR|J.26|9037420000|H0,75/17D ZH GR|J.29|
|9005860000|H0,5/14D W BD GSP|J.27|9012000000|HTG 58|I.14|9021110000|H4,0/20T OR|J.26|9037430000|H0,75/24,5D ZH GR|J.29|
|9005860000|H0,5/14D W BD GSP|J.25|9012500000|PZ 4|J.35|9021120000|H4,0/26T OR|J.26|9037440000|H1,0/15D ZH R|J.29|
|9005870000|H0,75/14 GRAU BD GSP|J.25|9012500000|PZ 4|J.6|9021130000|H6,0,0/20T GN|J.26|9037440000|H1,0/15D ZH R|J.30|
|9005880000|H1,0/14D R BD GSP|J.27|9012600000|PZ 16|J.8|9021140000|H6/26T GN|J.26|9037450000|H1,0/20D ZH R|J.30|
|9005880000|H1,0/14D R BD GSP|J.25|9012600000|PZ 16|J.35|9021150000|H10,0/22T BR|J.26|9037450000|H1,0/20D ZH R|J.29|
|9005890000|H1,5/14D SW BD GSP|J.25|9013600000|PZ ZH 16|J.8|9021160000|H10,0/28T BR|J.26|9037460000|H1,0/25,6D ZH R|J.29|
|9005890000|H1,5/14D SW BD GSP|J.27|9013600000|PZ ZH 16|J.35|9021170000|H16,0/24T W|J.26|9037460000|H1,0/25,6D ZH R|J.30|
|9005900000|H0,75/14T BL BD GSP|J.27|9013650000|PZ 6 HEX|J.35|9021180000|H16,0/28T W|J.26|9037470000|H1,5/16D ZH SW|J.30|
|9005910000|H2,5/14T GR BD GSP|J.27|9014350000|PZ 6 Roto|J.35|9021190000|H25,0/30T SW|J.26|9037470000|H1,5/16D ZH SW|J.29|
|9005990000|PZ 1.5|J.35|9014350000|PZ 6 Roto|J.7|9021200000|H25,0/36T SW|J.26|9037480000|H1,5/20D ZH SW|J.29|
|9006020000|SWIFTY|J.13|9014400000|HTI 15|J.35|9021210000|H0,25/10T GE SV|J.26|9037480000|H1,5/20D ZH SW|J.30|
|9006060000|SWIFTY SET|J.13|9018510000|H0,75/15 ZH W SV|J.28|9021220000|H0,25/12T GE SV|J.26|9037490000|H1,5/25,6D ZH SW|J.29|
|9006120000|CTI 6|J.35|9018520000|H0,75/15D ZH GR SV|J.29|9021230000|H0,75/14T HBL SV|J.26|9037490000|H1,5/25,6D ZH SW|J.30|
|9006210000|CTI 6 S|J.35|9018530000|H1,0/15 ZH GE SV|J.28|9021240000|H2,5/14T GR SV|J.26|9037500000|H2,5/18,5D ZH BL|J.28|
|9006450000|PZ 50|J.35|9018540000|H1,0/15D ZH R SV|J.29|9021250000|H4/17T OR SV|J.26|9037500000|H2,5/18,5D ZH BL|J.29|
|9006450000|PZ 50|J.9|9018540000|H1,0/15D ZH R SV|J.30|9025240000|H1,5/14S SW|J.32|9037510000|H2,5/20,5D ZH BL|J.29|
|9006590000|H1,5/17,5X SW SV|J.31|9018550000|H0,75/14TS HBL|J.32|9025570000|BIT E6.3 Z 0.6X3.5X39|J.20|9037510000|H2,5/20,5D ZH BL|J.28|
|9006630000|H1,5/19,5X SW SV|J.31|9018560000|H1,0/14S R|J.32|9025590000|BIT E6.3 Z 0.8X4.0X39|J.20|9037520000|H2,5/26,5D ZH BL|J.28|
|9006670000|H2,5/17,5X BL SV|J.31|9018580000|H2,5/18.5T ZH GR SV|J.30|9025690000|H1,5/12S R|J.32|9037520000|H2,5/26,5D ZH BL|J.29|
|9006710000|H2,5/21,5X BL SV|J.31|9018590000|H4,0/22T ZH OR SV|J.30|9025700000|H0,75/14S W SV|J.32|9037530000|H4,0/22D ZH GR|J.29|
|9006750000|H4,0/19,5X GR SV|J.31|9018650000|H1,0/15S ZH GE SV|J.28|9025710000|H1,0/14S GE SV|J.32|9037530000|H4,0/22D ZH GR|J.28|
|9006790000|H6,0/23,0X GE SV|J.31|9018690000|H1,0/15S ZH GE|J.28|9025720000|H1,5/14S R SV|J.32|9037540000|H4,0/28D ZH GR|J.29|
|9006830000|H10,0/24,5X R SV|J.31|9018860000|H10/24S ZH EB|J.28|9025740000|H0,25/10 HBL|J.22|9037540000|H4,0/28D ZH GR|J.28|
|9006870000|H16,0/25,5X BL SV|J.31|9018870000|H10/30S ZH EB|J.28|9025750000|H0,34/10 TK|J.22|9037550000|H6,0/25D ZH GE|J.29|
|9007440000|DMS 3|J.10|9018880000|H10,0/24DS ZH R|J.29|9025760000|H0,25/12 HBL|J.22|9037560000|H6,0/29D ZH GE|J.29|
|9007450000|AKKU DMS 3|J.10|9018890000|H10/30DS ZH R|J.29|9025770000|H0,34/12 TK|J.22|9037570000|H10,0/26D ZH R|J.29|
|9007460000|LADEGERAET DMS 3|J.10|9018910000|H0,25/5|J.33|9025780000|H0,25/12 HBL SV|J.22|9037580000|H10,0/30D ZH R|J.29|
|9007470000|DMS 3 SET 1|J.10|9019000000|H0,5/12D W|J.24|9025790000|H0,34/12 TK SV|J.22|9037590000|H16,0/29D ZH BL|J.29|
|9007480000|DMS 3 SET 2|J.10|9019000000|H0,5/12D W|J.26|9025860000|H0,75/16 W|J.22|9037600000|H16,0/38D ZH BL|J.29|
|9008320000|SD 0,5x3,0x80|J.15|9019010000|H0,5/14D W|J.26|9025870000|H0,5/16 OR|J.22|9037610000|H0,75/15T ZH HBL|J.30|
|9008330000|SD 0,6x3,5x100|J.13|9019010000|H0,5/14D W|J.24|9025870000|H0,5/16 OR|J.14|9037620000|H0,75/17T ZH HBL|J.30|
|9008330000|SD 0,6x3,5x100|J.15|9019020000|H0,5/16D W|J.26|9025880000|H50,0/25|J.33|9037630000|H0,75/24,5T ZH HBL|J.30|
|9008340000|SD 0,8x4,0x100|J.15|9019020000|H0,5/16D W|J.24|9025910000|H0,75/18 W|J.22|9037640000|H2,5/18,5T ZH GR|J.30|
|9008350000|SD 1,0x5,5x150|J.15|9019030000|H0,75/12D GR|J.24|9025930000|H1,0/18 GE|J.22|9037650000|H2,5/20,5T ZH GR|J.30|
|9008370000|SDI 0,4x2,5x75|J.14|9019040000|H0,75/14D GR|J.24|9025950000|H1,0/16 GE|J.22|9037660000|H2,5/26,5T ZH GR|J.30|
|9008380000|SDI 0,5x3,0x100|J.14|9019050000|H0,75/16D GR|J.24|9025960000|H0,75/14S W|J.32|9037670000|H4,0/22T ZH OR|J.30|
|9008390000|SDI 0,6x3,5x100|J.14|9019060000|H0,75/18D GR|J.24|9025970000|H1,0/14S GE|J.32|9037680000|H4,0/28T ZH OR|J.30|
|9008400000|SDI 0,8x4,0x100|J.14|9019070000|H1,0/12D R|J.24|9025980000|H1,5/14S R|J.32|9037690000|H6,0/25T ZH GN|J.30|
|9008410000|SDI 1,0x5,5x125|J.14|9019070000|H1,0/12D R|J.26|9026010000|H4/17 GR SV|J.22|9037700000|H6,0/29T ZH GN|J.30|
|9008430000|SDI 1,6x8,0x175|J.14|9019080000|H1,0/14D R|J.26|9026010000|H4/17 GR SV|J.24|9037710000|H10,0/26T ZH BR|J.30|
|9008450000|SDIZ 0.6X3.5X100|J.20|9019080000|H1,0/14D R|J.24|9026030000|H0,34/10 TK SV|J.22|9037720000|H10,0/30T ZH BR|J.30|
|9008460000|SDIZ 0.8X4.0X100|J.20|9019100000|H1,0/16D R|J.24|9026050000|H0,25/10 HBL SV|J.22|9037730000|H16,0/29T ZH W|J.30|
|9008470000|SDK PH0|J.15|9019100000|H1,0/16D R|J.26|9026060000|H0,5/14 OR SV|J.22|9037740000|H16,0/38T ZH W|J.30|
|9008480000|SDK PH1|J.15|9019110000|H1,0/18D R|J.26|9026070000|H0,75/14 W SV|J.22||||
|9008490000<br>9008500000|SDK PH2<br>SDK PH3|J.15<br>J.15|9019110000<br>9019120000|H1,0/18D R<br>H1,5/14D SW|J.24<br>J.26|9026080000<br>9026090000|H1,0/14 GE SV<br>H1,5/14 R SV|J.22<br>J.22|**9050000000**|||
|9008520000|SDK PZ0|J.15|9019120000|H1,5/14D SW|J.24|9026100000|H2,5/14 BL SV|J.22|9054030000|MEHA OB/UN 6² SPX 3|J.4|
|9008530000|SDK PZ1|J.15|9019130000|H1,5/16D SW|J.24|9026100000|H2,5/14 BL SV|J.24|9054080000|MEHA OB/UN 16² SPX 3|J.4|
|9008540000|SDK PZ2|J.15|9019130000|H1,5/16D SW|J.26|9028200000|H70,0/40 GE|J.22||||
|9008550000<br>9008560000|SDK PZ3<br>SDIK PH0|J.15<br>J.14|9019140000<br>9019140000|H1,5/18D SW<br>H1,5/18D SW|J.26<br>J.24|9028210000<br>9028220000|H95,0/44 R<br>H120,0/50 BL|J.22<br>J.22|**9120000000**|||
|9008570000|SDIK PH1|J.14|9019150000|H1,5/24D SW|J.24|9028230000|H150,0/54 GE|J.22|9129920000|SAK 4/EN RT|I.7|
|9008580000|SDIK PH2|J.14|9019150000|H1,5/24D SW|J.26|9028240000|H0,14/12 GR SV|J.22|9129930000|SAK 4/EN GE|I.7|
|9008590000|SDIK PH3|J.14|9019160000|H2,5/14D BL|J.22|9028250000|H0,14/10T BR SV|J.26|9129950000|SAK 4/EN GN|I.7|
|9008850000|SK WSD-S 1,5-10,0|J.16|9019160000|H2,5/14D BL|J.24|9028260000|H0,5/10 OR SV|J.22|9129960000|SAK 4/EN GR|I.7|
|9008860000|SKS 2,0-8,0|J.16|9019170000|H2,5/18D BL|J.22|9028270000|H0,5/16 OR SV|J.22||||
|9008870000|SKS 2,0-8,0 MR|J.16|9019170000|H2,5/18D BL|J.24|9028280000|H0,75/12 W SV|J.22||||
**X**
**X.25**
**X**
|**Order No.**<br>**Type**<br>**Page**<br>**9130000000**<br>9130980000 SAK 4/EN SW<br>I.7<br>9130990000 SAK 4/EN BR<br>I.7<br>**9150000000**<br>9154850000 AP OSC 10/16<br>I.6<br>9154860000 AP OSC 4<br>I.6<br>**9200000000**<br>9201940000 SDI T8<br>J.14<br>9202820000 H0,75/19S ZH W<br>J.28<br>9202830000 H0,75/19DS ZH GR<br>J.29<br>9202840000 H0,75/19TS ZH HBL<br>J.30<br>9202870000 H 1,5/24 XS SW<br>J.31<br>9202880000 H 2,5/24 XS BL<br>J.31<br>9202900000 H 0,5/16 S OR<br>J.32<br>9202910000 H0,5/16 DS Weiß<br>J.32<br>9205690000 SDI 0.4X2.0X60<br>J.14<br>9205700000 SDI 1.0X4.5X175<br>J.14<br>9205710000 SDI 1.0X5.5X175<br>J.14<br>**9420000000**<br>9426770000 H2,5/14TS GR<br>J.32<br>**9450000000**<br>9451000000 H35,0/30S<br>J.33<br>**9500000000**<br>9501160000 RSF 3/35<br>A.11<br>9501310000 KST 6<br>B.54<br>9501320000 KST 8<br>B.55<br>9501330000 KST 10<br>B.55<br>9501340000 KST 12<br>B.55<br>9501350000 QL 2 KST6<br>B.54<br>9501350000 QL 2 KST6<br>A.48<br>9501360000 QL 2 KST8<br>B.55<br>9501360000 QL 2 KST8<br>A.49<br>9501370000 QL 2 KST10<br>B.55<br>9501370000 QL 2 KST10<br>A.49<br>9501380000 QL 2 KST12<br>A.49<br>9501380000 QL 2 KST12<br>B.55<br>9502540000 QL 2 SAKK 4<br>D.2<br>9502550000 QL 3 SAKK 4<br>D.2<br>9502560000 QL 4 SAKK 4<br>D.2<br>9502570000 QL 10 SAKK 4<br>D.2<br>9502580000 VH 13.5 SAKK 4<br>D.2<br>9502600000 SAKK 4<br>D.2<br>9502610000 SAKK 10<br>D.3<br>9502630000 AP SAKK4/10 KER/WS<br>I.6<br>9502630000 AP SAKK4/10 KER/WS<br>D.3<br>9502630000 AP SAKK4/10 KER/WS<br>D.2<br>9502650000 QL 2 SAKK 10<br>D.3<br>9502660000 QL 3 SAKK 10<br>D.3<br>9502670000 QL 4 SAKK 10<br>D.3<br>9502680000 QL 10 SAKK 10<br>D.3<br>9502690000 VH 12.5 SAKK10<br>D.3<br>9503300000 KDKS 1/32<br>B.21<br>9503310000 KDKS 1/35<br>A.23<br>9503330000 AP KDKS1 1.5<br>I.6<br>9503340000 AP KDKS1 EN<br>I.6<br>9503340000 AP KDKS1 EN<br>C.7<br>9503370000 KST 5<br>B.54<br>9506940000 KST 6/35 M6X22<br>A.48<br>9506950000 KST 8/35 M8X30<br>A.49<br>9506960000 KST 10/35 M10X39<br>A.49<br>9506970000 KST 12/35 M12X37<br>A.49<br>9509420000 QL 2 SAKK 4 TIN<br>D.2<br>9509430000 QL 3 SAKK 4 TIN<br>D.2<br>9509440000 QL 4 SAKK 4 TIN<br>D.2<br>9509450000 QL 10 SAKK 4 TIN<br>D.2<br>9509460000 VH 13.5 SAKK4<br>D.2<br>9509470000 QL 2 SAKK 10 TIN<br>D.3<br>9509480000 QL 3 SAKK 10 TIN<br>D.3<br>9509490000 QL 4 SAKK 10 TIN<br>D.3<br>9509500000 QL 10 SAKK 10 TIN<br>D.3<br>9509510000 VH 12.5 SAKK10<br>D.3<br>9509570000 KSKM 1/32 G20<br>B.20<br>9509580000 KSKM 2/32 GZ 1X1/4<br>B.20<br>9509600000 KSKM 1/35 G20<br>A.22<br>9509610000 KSKM 2/35 GZ 1X1/4<br>A.22<br>9509620000 KSKM 3/35 GZ 1 1/4X1/4<br>A.23<br>9509630000 AP KSKM<br>I.6<br>**9520000000**<br>9528300000 KST 5/35 M5X18<br>A.48<br>9528320000 KST 8/35 M8X30<br>A.49<br>9528330000 KST 10/35 M10X39<br>A.49<br>9528340000 KST 12/35 M12X37<br>A.49<br>**9530000000**<br>9532470000 AP KDKS1 1.5 DB<br>I.6|**Order No.**<br>**Type**<br>**Page**<br>**9540000000**<br>9540000000 ZEW 35<br>H.13<br>**9910000000**<br>9918370000 DMS MANUELL 0,5-1,7<br>J.18<br>9918380000 DMS MANUELL 2,0-8,0<br>J.18<br>9918390000 DMSI MANUELL 0,5-1,7<br>J.19<br>9918400000 DMSI MANUELL 2,0-8,0<br>J.19<br>9918410000 WK SI 0,4x2,5<br>J.19<br>9918420000 WK SI 0,5x3,0<br>J.19<br>9918430000 WK SI 0,6x3,5<br>J.19<br>9918440000 WK SI 0,8x4,0<br>J.19<br>9918450000 WK SI 1,0x5,5<br>J.19<br>9918460000 WK IK PH0<br>J.19<br>9918470000 WK IK PH1<br>J.19<br>9918480000 WK IK PH2<br>J.19<br>9918490000 WK IK PZ0<br>J.19<br>9918500000 WK IK PZ1<br>J.19<br>9918510000 WK IK PZ2<br>J.19<br>9918520000 WK S 0,4x2,5<br>J.18<br>9918530000 WK S 0,5x3,0<br>J.18<br>9918540000 WK S 0,6x3,5<br>J.18<br>9918550000 WK S 0,8x4,0<br>J.18<br>9918560000 WK S 1,0x5,5<br>J.18<br>9918570000 WK K PH0<br>J.18<br>9918580000 WK K PH1<br>J.18<br>9918590000 WK K PH2<br>J.18<br>9918600000 WK K PZ0<br>J.18<br>9918610000 WK K PZ1<br>J.18<br>9918620000 WK K PZ2<br>J.18|**Order No.**<br>**Type**<br>**Page**|**Order No.**<br>**Type**<br>**Page**|
|---|---|---|---|
**X.26**
**X**
**X.27**
## Addresses worldwide
> **[United Arab Emirates ]** Weidmuller Middle East FZE **CA[ Canada ]** W Interconnections Canada Inc. **EC[Ecuador ]** Elsystec S.A. **ID[ Indonesia ]** PT. NEGO ELECTRINDO P.O. Box # 8591 10 Spy Court, Markham, Vasco de Contreras N35-251 Ruko Mega Grosir Cempaka Mas, SAIF-Zone Ontario L3 R5 H6 y Mañosca Blok I No 20 – 22 Sharjah – VAE Phone +1 905 475-1507 Phone +593 2 2455698 Jl. Let.Jend. Suprato – Phone +971 6 5572723 Fax +1 905 475-5855 +593 2 2245241 JAKARTA 10640 Fax +971 6 5572724 info1@weidmuller.ca Fax +593 2 2456510 Phone +62 21 42882255 wme.info@weidmueller.com www.weidmuller.ca elsystec@elsystec.com.ec Fax +62 21 42882266 sales@negoelectrindo.co.id
> **[ Argentina ]** CPI SA Bauness 2660 **CH[ Switzerland ]** Weidmüller Schweiz AG Rundbuckstrasse 2 **EE[ Estonia ]** Alter Electric OÜ Gaasi 4a **IE[[ Ireland ]]** A.P. Haslam Ltd. 1431 Buenos Aires 8212 Neuhausen am Rheinfall 11415 Tallinn 14 Sunshine Ind. Estate Phone +54 11 45238008 Phone +41 52 6740707 Phone +372 6519666 Crumlin Road compras@cpi.com.ar Fax +41 52 6740708 Fax +372 6519667 Dublin 12 info@weidmueller.ch alter@alter.ee Phone +353 1 453-2522
> **[[ Austria ]]** www.weidmueller.ch www.alter.ee Fax +353 1 453-2949
> **[[ Ireland ]]** A.P. Haslam Ltd. 14 Sunshine Ind. Estate Crumlin Road Dublin 12 Phone +353 1 453-2522 Fax +353 1 453-2949 paul.haslam@aphaslam.ie
> **[[ Austria ]]** Weidmüller Ges.m.b.H. www.weidmueller.ch Industriezentrum Nö Süd **CL[ Chile ]** Straße 2, Objekt M2 Felipe Bahamondes S.A./ATS AGRO 2355 Wiener Neudorf Servicios Agroindustriales Phone +43 2236 6708-0 Maria Luisa Santander 0475 Fax +43 2236 6708-199 Providencia office.at@weidmueller.com Casilla 3425 Santiago
> **[[ Australia ]]** Weidmüller Pty. Ltd. Phone +56 2 341-1271 Fax +56 2 341-1275 Fax +56 2 341-1275 43 Huntingwood Drive felipe@atsintech.com
> **[ Egypt ]** Standard Electric 87, Mohamed Farid Street Heliopolis, Cairo Phone +20 6 42 29 77/ 6 42 29 88 Fax +20 6 42 29 55 stdelec@rite.com
> **[ Israel ]** A.U.Shay Ltd. 23 Imber St. Petach-Tikva Phone +972 3 9233601 Fax +972 3 9234601 shay@uriel-shay.com www.uriel-shay.com
> **[[ Australia ]]** Weidmüller Pty. Ltd. Phone +56 2 341-1271 Fax +56 2 341-1275 Fax +56 2 341-1275 43 Huntingwood Drive felipe@atsintech.com Huntingwood, NSW, 2148 P.O.Box 6944 **CN[China]** Weidmüller Interface International Blacktown Trading (Shanghai) Co., Ltd. NSW, 2148 12 F, Century Ba-Shi Building, Phone +61 2 9671-9999 No. 398 Huaihai Road (M) Fax +61 2 9671-9911 Shanghai 200020 info@weidmuller.com.au P.R. China www.weidmuller.com.au Phone +86 21 63868188 Fax +86 21 63867177
> **[[ Azerbaijan ]]** www.cnweidmuller.com
> **[ Spain ]** Weidmüller S. A. Narcis Monturiol 11-13 Pol.Ind. Sudoeste 08960 Sant Just Desvern Barcelona Phone +34 93 4803386 Fax +34 93 3718055 weidmuller@weidmuller.es www.weidmuller.es
> **[ Israel ]** ATEKA Ltd. 23 Hayetzira St. Kiryat Aryeh 49130 Petach-Tikva, Israel Phone +972 3 9392344 Fax +972 3 9243273 marketing@ateka.co.il www.ateka.co.il
> **[ Finland ]** JUHA-ELEKTRO OY Kylvöpolku 6, P. O. Box 57 00681 Helsinki Phone +358 10 8328 100 Fax +358 10 8328 169
> **[ France ]** Weidmüller EURL 12, Chaussée Jules César B.P. 263 Osny 95523 CERGY PONTOISE Cedex Phone +33 1 34245500 Fax +33 1 34245501 mail@weidmuller.fr www.weidmuller.fr
> **[ India ]** Weidmüller Representative office Vijay Dattani Mobile +91 98440 97366 vdattani@eth.net
> **[[ Azerbaijan ]]** West Industries Ltd. www.cnweidmuller.com Caspian Plaza, 5-th Floor 44 J. Jabbarly Str., Baku **CO[ Colombia ]** Automatizacion Avanzada S. A. Phone +99412 499 15 15 Cr 97 # 24C-23 Bodega 4 Bogotá Fax +99412 499 14 93 Phone +57 1 5478510 sales@west-i.com Fax +57 1 4132285 productos@
> **[[ Bosnia and Herzegovina]]** automatizacionavanzada.com
> **[ Iran ]** TAF Co. 72, Iranshahr Av. Unit 5, 15816 Teheran Phone +98 21 8831-7851 Fax +98 21 8882-0268 info@taf-co.com
BH ES Elektrosistem d.o.o. **[[ Bosnia and Herzegovina]]** automatizacionavanzada.com ul. J. Veselinovica 18 78000 Banja Luka **CR[ Costa Rica ]** ELVATRON S.A. Phone +387 51 317500 400 Norte Fax +387 51 317500 Banco Costa Rica, la Uruca, elsist@inecco.net San José www.elektrosistem.co.yu Phone +506 2 961060 Fax +506 2 960328 **[ Belgium ]** Weidmüller Benelux B.V. dirk.haase@elvatron.com Mechelsesteenweg 519 bus 6 en 7 1930 Nossegem **CS[[ Serbia ]]** ES-YU Elektrosistem Phone +32 (0)2 752 40 70 Pariske komune 41 Fax +32 (0)2 751 36 06 11070 Novi Beograd info@weidmueller.be Phone +381 11 697212
> **[ Iceland]** Samey Automation Center Lyngas 13, 210 Garoabaer, Phone +354 510 5200 Fax +354 510 5201 samey@samey.is
> **[Great Britain ]** Weidmuller Ltd. 1 Abbey Wood Road Kings Hill, West Malling Kent ME19 4YT Phone +44 845 094 2006 Fax +44 1732 874296 sales@weidmuller.co.uk www.weidmuller.co.uk
> **[[ Serbia ]]** ES-YU Elektrosistem Pariske komune 41 11070 Novi Beograd Phone +381 11 697212 Fax +381 11 693608 esyu@eunet.yu www.elektrosistem.co.yu www.elektrosistem.co.yu
> **[ Italy]** Weidmüller S.r.l.
Via Albert Einstein 4 20092 Cinisello Balsamo Milano Phone +39 02 660681 Fax +39 02 6124945 weidmuller@weidmuller.it www.weidmuller.it
> **[ Bulgaria ]** Weid-Bul EOOD esyu@eunet.yu www.elektrosistem.co.yu 1113 Sofia 33 A 'Nezabravka' Str. bl. 315/3/10 **CZ[ Czech]** Weidmüller s. r. o. Phone +359 2 9632560 Videnska ul. 340 weidbul@nat.bg 25242 Vestec u Prahy www.weidbul.com Phone +420 2 44001400 Fax +420 2 44001499
> **[[ Bahrain ]]** office@weidmueller.cz
> **[ Greece ]** Electrorama S.A. Phone +30 2410 552533 Fax +30 2410 283463 weidmuller@electrorama.com.gr
> **[ Hong Kong ]** United Equity Limited Suite B, 11/F International Industrial Centre 2-8 Kwei Tei Street, Fotan, Shatin Phone +852 26876739 Fax +852 26876735 united_equity@sinatown.com
> **[Jordan ]** Trans Jordan for Electro Mechanic Supplies PLC. P.O.Box: 330607 Amman 11133 Phone +962 6 533 2020 Fax +962 6 533 5800 transjordan@batelco.jo
> **[[ Bahrain ]]** Khayber Trading Company P.O. Box 1976 Manama, Phone +973 17720747 P.O. Box 1976 Manama, Fax +973 17720331 khayber@batelco.com.bh
Phone +973 17720747 P.O. Box 1976 Manama, **DE[ Germany ]** Weidmüller GmbH & Co. KG Fax +973 17720331 Ohmstraße 9 khayber@batelco.com.bh 32758 Detmold Phone +49 5231 1428-0 Conexel Conexoes Elétricas Ltda. **[ Brazil ]** Fax +49 5231 1428-116 weidmueller@weidmueller.de Rua Garcia Lorca, 176- V. Paulicéia, www.weidmueller.de 09695-900, Sao Bernardo do Campo - SP Phone +55 11 43669600 **DK[ Denmark ]** Knud Wexøe A/S Fax +55 11 43621677 Skaettekaeret 11 vendas@conexel.com.br P.O. Box 152 www.conexel.com.br 2840 Holte Phone +45 45465800 **[Belarus ]** Technikon Ltd. Fax +45 45465801 wexoe@wexoe.dk Oktyabrskaya Str. 16/5 Apt. 704, 220030, Minsk Phone +375 17 2104626 Fax +375 17 2275830 weidmueller@technikon.by
> **[ Croatia ]** Elektro Partner d.o.o. Radnicka cesta 22 10000 Zagreb Phone +385 1 6184793 Fax +385 1 6184795 elektropartner@zg.htnet.hr
> **[Japan ]** Nihon Weidmüller Co. Ltd. Asahi Seimei Bldg. 11F 1-14-1 Fuchucho Fuchu-shi Tokyo 183-0055 Phone +81 42 330-7891 Fax +81 42 330-7895 www.weidmuller.co.jp
> **[ Hungary]** Weidmüller Kereskedelmi Kft Mádi u. 50 1104 Budapest P. O. Box 22 1507 Budapest Phone +36 1 464-7888 Fax +36 1 3827701 info@weidmueller.hu
> **[Korea ]** Weidmüller Co., Ltd. 6floor, Seahwa building, 242-54 Nonhyun-dong, Kangnam-Gu Seoul Zip: 135-830 Phone +82 2 5160003 Fax +82 2 5160090 info@weidmuller.co.kr
**X**
**X.28**
Group companies
Agency abroad
**KW Kuwait** KANA CONTROLS General **NO[ Norway ]** Siv. Ing. J. F. Knudtzen A/S **SA[ Saudi Arabia ]** Al Abdulkarim Holding Co. **US[United States]** W-Interconnections, Inc. Trading & Cont. CO. W.L.L. Billingstadsletta 97 P.O Box. 4 821 Southlake Boulevard, A1 Rai Industrial Area, 1396 Billingstad, P.O. Box 160 Dammam 31411 Richmond, VA 23236 Plot 28-30, St. 31 1378 Nesbru Phone +9668337110 Ext.168 Phone +1 804 7942877 P.O.Box: 25593 Phone +47 66 983350 salehsk@akh.com.sa Fax +1 804 3792593 Safat, 13116 Kuweit Fax +47 66 980955 info@weidmuller.com Phone +965-474 1373/4 patorgersbraaten@jfknudtzen.no SESCO P.O. Box 3298 www.weidmuller.com Fax +965-474 1537 Al Khobar 31952 info@kanacontrols.com **NZ[ New Zealand ]** Cuthbert S. Steward Limited Phone +966 3 882 9546 Fax +966 3 882 9547 **UY[ Uruguay ]** Rewo Uruguay S.A **KZ[ Kazakhstan ]** Please contact our 27 Te Puni Street POB 38496 Petone Customer.Service@sesco-gex.com www.sesco-gex.com Av. Bolivia 2001 esq Rocafuerte Phone / Fax +598 260 48522 Weidmüller branch office Petone, Wellington rewo@rewouruguay.com.uy in Moscow, Russia Phone +64 4 5686156 Fax +64 4 5686056 **SE[ Sweden]** Weidmüller AB www.rewouruguay.com.uy **LB** Beirut **[ Lebanon ]** PROGRESS ENGINEERING **OM Oman** DAN INTERNATIONAL LLC. P.O. box 31025 200 49 Malmö Axel Danielssons väg 271 **UZ[ Uzbekistan ]** OOO “Elektro Potential” Gani Mavljanova str., 2B Phone +961 1 444664 PO.BOX 2901 Phone +46 (0) 7 71 43 00 44 100084 Tashkent Fax +961 1 561880 111 Seeb Fax +46 (0) 40 37 48 60 Phone +998 98-3003821 progress@inco.com.lb Phone +968 503 677 www.weidmuller.se Fax +998 71-1249286 Fax +968 503 755 info@weidmuller.se mz1958@yandex.ru **LT** Phone +370 45582828 **[ Lithuania ]** ELEKTROS IRANGA Tinklu g.29a, 5319 Panevezys, **PE** yedu@danintl.com **[ Peru ]** TECSOL S.A.C. **SG[ Singapore ]** Weidmuller Pte Ltd 70 Bendemeer Road **VE[ Venezuela ]** Somerinca C.A. 3era transversal de Los Dos caminos, Fax +370 45582727 Huandoy Nº : 501, Lima 32 #04-03 Luzerne Qta Corazon de Jesús. 4ta de info@eliranga.lt Phone / Fax +51 1 562-0004 Singapore 339940 Montecristo. Caracas info@tecsol-peru.com Phone +65 6841 5311 Phone +58 212 2352748 **LU[ Luxembourg ]** Weidmüller Benelux B.V. Phone +352 24 527145 **PH[ Philippines ]** Enclosure Systems Specialists Inc Fax +65 6841 5377 info@weidmuller.com.sg www.weidmuller.com.sg Fax +58 212 2399341 klocmoeller@cantv.net Fax +352 24 527147 info@weidmueller.lu 2241 Don Chino Roces Avenue W-15 La Fuerza Compound **SI[ Slovenia] VN[Viet Nam ]** AUMI Co., Ltd Makati City 1231 Philippines Elektrospoji d.o.o. E1, La Thanh Hotel, **LV[ Latvia ]** PROFS Latvija SIA Phone +63 2 813 8580sales_encsys@pldtdsl.net Stegne 27, 1000 Ljubljana Phone +386 15113810 218 Doi Can Street, Lieu Giai Ward, Ba Dinh District, K. Ulmana gatve 140 Fax +386 15111604 Hanoi City, S.R. LV-1029 Riga Phone +371 7870557 **PK[Pakistan]** Kana Controls (Pak) elektrospoji@siol.net www.elektrospoji.si Phone +84 4762 8601 Fax +84 4266 1391 Fax +371 7870541 Apartment No. 33 C III aumi@aumi.com.vn edgars.vilkins@profs.lv www.profs.lv Chenab Block, Allama Iqbal Town **SK[ Slovakia]** Elektris s.r.o. Linh Kim Hai Co,. Ltd Lahore Racianska 188 78 Hoa Cuc Street Ward 7, **MD Moldova** BERHORD A&D srl Phone +92 42 5419948 +92 42 7845160 SK 831 53 Bratislava Phone +421 2 4920 0111 Phu Bhuan District, Ho Chi Minh City Off 414. b-dul Decebal, 3, Fax +92 42 5422895 bratislava@elektris.sk Phone +84 8517 1717 Chisinau, RM nadeem@kanapak.com Fax +84 8517 1818 Phone +373 22 507137 Fax +373 22 507134 www.kanapak.com **TH[Thailand ]** Pisanu Engineering Co., Ltd lkh@linhkimhai.com.vn atiuleanu@berhord.com **PL[ Poland ]** 800/2 Asoke Dindaeng Road, New Sky Co., Weidmüller Sp. z o.o. Dindaeng, Bangkok 10400 Ltd44/28 Tan Hai Street, **MK Macedonia** ELEKTRO – SMK dooel ul. Gol˛edzinowska 10 03-302 Warszawa, Poland Phone +66 2 245 9113 Fax +66 2 2463214 Ward 13, Tan Binh District, Ho Chi Minh City UL. III Makedonska brigada b.b. Phone +48 22 5100940 pisanu@kanit.co.th Phone +84 8812 6593 1000 Skopje Fax +48 22 5100941 www.pisanu.co.th Fax +84 8812 6594 Phone +389 22 460 295 biuro@weidmuller.com.pl newsky-e@hcm.vnn.vn Elektro-smk@telekabel.net.mk Fax +389 22 460 298 www.weidmuller.pl **TN[Tunisia ]** FAZE Services www.newsky-e.com **MT[ Malta ]** Electrical Supplies & Services Ltd **PT[ Portugal ]** Weidmüller - Sistemas de Interface, S. A. Rue du Lac Turkana – Immeuble Nour El Bouhaira 1053 Les Berges du Lac – Tunis **ZA** Phone +27 11 452 1930 **[South Africa]** Phambili Interface (Pty) Ltd 104 J. Sciberras Str. Estrada Outeiro Polima, Lote B, Tunisia Fax +27 11 452 6455 Hamrun HMR 08 N° B2, Escritório 2 - Abóboda Phone +216 71 964-266 sales@weidmuller.co.za Phone +356 21 255 777 2785-518 Sao Domingos de Rana Fax +216 71 964-265 www.weimuller.co.za Fax +356 21 255 999 Lisboa contact.fazeservices@faze.com.tn robert@ess.com.mt Phone +351 21 4459190 www.groupefaze.com Fax +351 21 4455871 **MX[ Mexico ]** weidmuller@weidmuller.pt **TR[[ Turkey]]** W Interconnections, S.A. de C.V. www.weidmuller.pt Weidmüller Elektronik Ticaret Ltd. ¸Sti. Col. San Rafael Oriente Puebla, Pue. C.P. 72029 Blvd. Hermanos Serdán No. 698 **[QA][Qatar ]** Doha Motors (Technical Division) Phone +90 216 5371070 (Pbx) Kavacik Mah. Mihrabad Cad. 143/1 34810 Beykoz – Kavacik Mah. Mihrabad Cad. 143/1 34810 Beykoz – 34810 Beykoz –[[.]] Istanbul / Turkey **DE** Postfach 3030 Weidmüller Interface GmbH & Co. KGWeidmüller Interface GmbH & Co. KG **[[ Other countries ]]** Phone +52 222 2686266 to 68 ext.101 Post Box No. 145 Fax +90 216 5371077 32720 Detmold Fax +52 222 2686219 Al Wakrath Road info@weidmuller.com.tr Klingenbergstraße 16 clientes@weidmuller.com.mx Doha 32758 Detmold www.weidmuller.com.mx Phone +974 465 1441 Fax +974 465 4579 **TW[[[ Taiwan ]]]** Fittatek Co., Ltd. Phone +49 5231 14-0 Fax +49 5231 14-20 83 Fax +49 5231 14-20 83 **MY[[Malaysia ]]** dmtctech@qatar.net.qa 12F No. 185 Fu-Kuo Road, info@weidmueller.com
> **[[ Turkey]]** Weidmüller Elektronik Ticaret Ltd. ¸Sti. Phone +90 216 5371070 (Pbx) Kavacik Mah. Mihrabad Cad. 143/1 34810 Beykoz – Kavacik Mah. Mihrabad Cad. 143/1 34810 Beykoz – 34810 Beykoz –[[.]] Istanbul / Turkey **DE** Postfach 3030 Weidmüller Interface GmbH & Co. KGWeidmüller Interface GmbH & Co. KG **[[ Other countries ]]** Fax +90 216 5371077 32720 Detmold info@weidmuller.com.tr Klingenbergstraße 16 32758 Detmold
> **[[[ Taiwan ]]]** Fittatek Co., Ltd. Phone +49 5231 14-0 Fax +49 5231 14-20 83 Fax +49 5231 14-20 83 12F No. 185 Fu-Kuo Road, info@weidmueller.com www.weidmueller.com
> **[[[ Taiwan ]]]** Fittatek Co., Ltd. 12F No. 185 Fu-Kuo Road, Tso Ying Dist Kaohsiung Phone +886 7 556 0858 Fax +886 7 556 3279 stanley@fittatek.com.tw
> **[[Malaysia ]]** dmtctech@qatar.net.qa Connect Plus Technology Sdn Bhd No. 43, Jalan PJS 11/22, **RO[ Romania]** Bandar Sunway, 46150 Petaling Jaya Rominterface Impex SRL Selangor Darul Ehsan Phone +40 21 3220230
> Phone +60 3 5633 7363 office@rominterface.ro Fax +60 3-5633 6562 paul@cptech.com.my **RU[ Russia]** www.cptech.com.my Weidmüller Representative Office Shabolovka street 2
> **[ Netherlands ]** Weidmüller Benelux B.V. 119049 Moskau, Russia Phone +7 095 771-6940 Franciscusweg 221 Fax +7 095 771-6941 1216 SE Hilversum info@weidmueller.ru Postbus 1505 www.weidmueller.ru 1200 BM Hilversum Phone +31 35 6261261 Fax +31 35 6234569 info@weidmuller.nl www.weidmuller.nl
> **[Taiwan ]** Eucan Enterprise Ltd. No. 145 He Ping 2nd Rd Kaohsiung Phone +886 7 715 6610 Fax +886 7 715 8748 mark@eucan.com.tw www.eucan.com.tw
> **[ Ukraine ]** TEKO INTERFACE ooo ul. Lewanewskogo 6 03058 Kiew Phone +38 044 401 09 90/91/92 Fax +38 044 401 08 64 weidmueller@tekointerface.com www.tekointerface.com.ua
**X**
**X.29**
**X**
We cannot guarantee that there are no mistakes in the publications or software provided by us to the customer for the purpose of making orders. We try our best to quickly correct errors in our printed media. For this purpose we list corrections, which have been identified after publishing printed media, on our web site at www.weidmueller.com. For convenience we list these corrections against product catalogue number and/or page number. This Internet-database is part of our catalogue.
All orders are based on our general terms of delivery, which can be reviewed on the websites of our group companies where you place your order. On demand we can also send the general terms of delivery to you.
**X.30**
Updated at June 8, 2026
Weidmüller is a leading international provider of advanced solutions for electrical connectivity, power transmission, and the conditioning of signals and data in industrial environments. Recognized globally for engineering excellence, the company develops innovative components designed to optimize automation, ensure reliable power distribution, and streamline complex control panel assemblies. Our extensive portfolio of Weidmüller components is strongly centered around their industry-leading connectivity solutions. We carry a vast selection of terminal blocks to suit any application, including pluggable terminal blocks, headers and sockets, wire-to-board solutions, and rugged DIN rail terminal blocks. To support complete and organized installations, we also provide a comprehensive range of standard and fused terminal blocks, power distribution blocks, interface modules, and essential accessories like terminal block markers. Beyond core connectivity, our offering includes critical Weidmüller components for system protection and control. We supply a robust selection of circuit breakers, featuring magnetic hydraulic, thermal, and electronic variants to safeguard sensitive equipment. Additionally, our inventory encompasses dependable power relays, solid-state relays, and AC/DC converters, equipping engineers with the high-quality parts needed to build secure, efficient, and fully integrated industrial automation systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →